World Excel WT530TC15 Wireless Thermostat User Manual
World Excel Company Ltd Wireless Thermostat
User Manual
Dimension in mm(Transmitter) Button Description For changing the system mode: OFF: system off HEAT: heating only on COOL: cooling only on. For changing the Setting Menu. (Fan, Time, Program) To adjust temperature setpoint (temporary override) MODE WT530 Programmable Thermostat Heat/Cool/Off Instruction Manual 24Vac (915MHz) 170803 SET Before Installation UP & DOWN LCD Turn off WT530R Receiver, all electronic source and electrical devices which will be connected before installation and maintenance. DEFROST WT530R receiver Installation The installer must be a trained service personnel. Installation Location The WT530T thermostat should be mounted on an inner wall ~5 feet above the floor in a position where it is readily affected by changes of the general room temperature with freely circulating air. Using the accessory screws and wall anchors provided, mount the receiver with the key-hole at the back. Open the front door and remove the battery compartment that hide the second screw hole. (This unit does not use battery; the battery compartment is a dummy to cover the screw hole.) LO HI -- Communication Setup 1. 2. 3. 4. Prevent direct exposure to sunlight, drip or splash. Do not place the unit at a location where air circulation is low, or where there are great temperature changes (e.g. near door). Do not place the thermostat near heat generating sources (e.g. radiators, hot air vents, TV or lights). 5. WT530T transmitter Installation 6. Opening Pull out the battery drawer. Then lightly press on the spot shown below in order to detach the front shell from the base. 3. 4. Power on WT530R receiver, all LED light up then turn off. Select the communication address at the WT530T transmitter. Power on the WT530T transmitter (thermostat). Press and hold the setup key on the receiver for 1 second, then the setup LED will be flashing. Press and hold MODE and SET buttons on the thermostat, enter to the initial pairing mode (“PA” shown on screen for 5 second). If the pairing is completed, the receiver setup LED will turn on. Wiring In case the RF receiver is interfered by other wireless products, power OFF the receiver and change to other address. Redo the above steps with another address to reestablish a communication with the receiver. There are 5 terminals. R and C connect to 24V power supply. Terminal W is for heating , terminal Y is for cooling and terminal G is for fan. Time Setting Mounting 1. 2. Description In heat mode, when temperature is below 5°C / 40°F, Heater is on regardless of the setting temperature. Below 0°C / 32°F, heating will be activated in Heat Mode. Above 40°C/ 99°F. cooling will be activated in Cool Mode. Sensor is shortened or not connected. Ensure that the surface is level. Place the cables at the hole near the terminal block. Insert 2 pcs of wall anchors into the holes of the wall. Fasten the thermostat with 2 pcs of long screws through the 2 mounting holes. 1. 2. 3. 4. 5. 6. Press SET button to enter Setting Menu. Press UP or DOWN button to display CLOC and press SET button. Press NEXT button to select the item that you want to change (Day of week, Hour or Minute). Press UP or DOWN button to adjust the item. Press MODE button to confirm the setting and return to Setting Menu. *** Press MODE button to return to Normal Display Mode. Temperature Control This product can work as a simple setback thermostat or a programmable thermostat. By default, this product is configured as a simple setback thermostat (Program Off). Program On Communication address Set communication address for Communication Setup you wish to use. Batteries Insertion Pull out the battery drawer and insert 2 fresh AAA alkaline batteries into the drawer according to the polarity marked inside, then slide the drawer back into place. WT530T Operation Upper position: 1 Lower position: 0 When the unit is powered on, all the LCD segments are ON and then the first display screen is Normal Display Mode as below picture. When program is on, this thermostat will control the output according to the programmed time and temperature. The Default Program Settings are as below: Heat Mode: Time UP Button Room Temperature DOWN Button MODE Button SET Button Time Zone WAKE OUT BACK SLEEP MON~FRI Time 6AM 8AM 6PM 10PM °F/°C 70/21.0 61/16.0 70/21.0 61/16.0 SAT Time 8AM 10AM 6PM 11PM °F/°C 70/21.0 61/16.0 70/21.0 61/16.0 SUN Time 8AM 10AM 6PM 11PM °F/°C 70/21.0 61/16.0 70/21.0 61/16.0 Cool Mode: Time Zone WAKE OUT BACK SLEEP MON~FRI Time 6AM 8AM 6PM 10PM °F/°C 75/24.0 85/29.5 75/24.0 85/29.5 SAT Time 8AM 10AM 6PM 11PM °F/°C 75/24.0 85/29.5 75/24.0 85/29.5 SUN Time 8AM 10AM 6PM 11PM °F/°C 75/24.0 85/29.5 75/24.0 85/29.5 Program Setting The above program time and temperature can be modified. To adjust Heat/Cool program settings: 1. In Heat/Cool Mode, press SET button to enter Setting Menu. 2. Press UP or DOWN button to display PROG. 3. Press SET button to enter program setting: “ON”/”OFF”. 4. Press UP or DOWN button to select program on / program off. 5. Make sure “On” is selected, press SET button to select the item that you want to change (Weekday/Weekend, Four Zones, Hour, Minute or Setting Temperature). 6. Press UP or DOWN button to adjust the item. 7. Press MODE button to return to Weekday/Weekend program 8. Press MODE button again, to confirm the setting and return to Setting Menu. 9. *** Press MODE button to return to Normal Display Mode. Temporary Override When Program is On, this thermostat controls the output according to the program. If you want to override the programmed temperature temporarily: 1. Press UP or DOWN button to adjust Heat / Cool setting temperature setpoint with displayed. 2. In Heat Mode, only Heat setting temperature can be adjusted. 3. In Cool Mode, only Cool setting temperature can be adjusted. 4. The Heat / Cool setting temperature will be confirmed and the thermostat will return to Normal Display Mode, if no key is pressed for 10 sec. Temporary Override Mode will last until the next programmed time (zone) begins. At that time, the Heat / Cool setting temperature will follow the programmed setting temperature and (default) When Program is Off, this thermostat controls the output according to a single setpoint like a simple setback thermostat. To set the unit to be Program Off, follow the above “Program Setting” to select Program Off. When this thermostat is Program Off, the Program Mode will be disabled and the time zone icons will disappear in Normal Display Mode. To adjust the setpoint at Program Off: 1. Press UP or DOWN button to adjust the Heat / Cool setting 2. 3. 4. will NOT be shown in Program temperature. The icon Off. In Heat Mode, only Heat setting temperature can be adjusted. In Cool Mode, only Cool setting temperature can be adjusted. *** The Heat / Cool setting temperature will be confirmed. Fan Operation If FAN ON is selected, fan runs continuously. If FAN AUTO is selected, fan runs only when the Heating or Cooling system is on. Fan will be turned off 2 minutes after the Heating / Cooling system is off. Fan Mode setting: 5. Press SET button to enter Setting Menu. Press UP or DOWN button to display FAN and press SET button. Press UP or DOWN button to select FAN ON / FAN AUTO. Press MODE button to confirm the setting and return to Setting Menu. *** Press MODE button to resume to Normal display mode 1. In Normal Display Mode, press and hold UP and DOWN buttons for 5 seconds to change the temperature calibration display and the current temperature will flash, 2. Press UP and DOWN button to calibrate the temperature. The maximum range to be adjusted is +/- 3.0°C or +/- 6°F, in step of 0.5°C / 1°F. 3. ***Press MODE key to confirm the setting and return to Normal Display Mode. Advanced Setting Advanced Setting contains Function Setting Selection and Temperature Calibration and Room Temperature Display. Function Setting Selection Settingbutton Function Type button button 1. Press and hold SET and DOWN buttons for 2 seconds to enter Advanced Setting Mode. 2. The left letters represent Function Type; the right letters represent the settings. 3. Press UP or DOWN button to adjust the setting. 4. *** Press MODE button to select Function Type or to return to Normal Display Mode at the end of Function Setting selection. Table of the Function Setting Selection Function Type Description LCD Display Fan Control FC Temperature Display Unit dE Temperature Control Span SP will disappear. Or can be stopped manually by pressing MODE key. Program Off 1. 2. 3. 4. 12hr/24hr Selection Heater Minimum-Off Delay hr dL Setting E (Electrical Heat) (default) O (Gas/Oil Heat) °C °F (default) 05 (+/- 0.5°C ) 10 (+/- 1.0°C ) 10 (+/- 1°F) (default) 20 (+/- 2°F) 12 (default) 24 S (10 seconds) (default) L (4 minutes off time) Temperature Control Span : It controls how much the room temperature can be deviated from the setpoint. A smaller degree will result in a more accurate control. A larger degree will result in less on/off cycling and it usually saves more energy. Fan Control : It should be set according to the type of Heating system used. Select “E” for Electric Heat, fan will be On when Heat is On. Select “O” for Gas Heating or Oil Heating, fan will NOT be on when Heat is On. Heater Minimum Off Delay : It should be set according to the heater type. Select “L” if compressor is used for heating. Select “S” when a compressor is not used. Specification *** The operation will return to Normal Display Mode if no key is pressed for 10 sec. WT530T Transmitter 1. RF transmission: 2. Power Supply: 3. Temperature Measurement: 4. Accuracy: 5. Resolution: 6. Heat/Cool Setting: 7. Sensing Element: 915MHz 2 x AAA Alkaline Batteries 0 - 40°C / 32 - 99°F ±0.5°C / 1°F 0.5°C /1°F 5 - 35°C / 40 - 95°F NTC Thermistor RT530R Receiver 1. RF transmission: 2. Power Supply: 3. Rating: 4. Relay Contact Voltage: 5. Relay Contact Current: 6. Operating Temperature: 7. Storage Temperature: 915MHz 24Vac 50/ 60Hz 24Vac 50/ 60Hz 1A Max 24Vac Max. 50/60 Hz 1A Max. 0 - 50°C / 32 - 122°F -5 - 50°C / 23 -122°F FCC STATEMENT Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The Responsible party information: World Excel Company Limited Room B ,26/F, Capital Temperature Calibration This thermostat is calibrated at factory and calibration is generally not required. However, in the event that a deviation is found. Trade Centre, 62 Tsun Yip St., Kwun Tong, H.K. Technical Helpline Tel: 852 - 2304 0993
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : user Create Date : 2017:08:03 15:50:16+08:00 Modify Date : 2017:08:03 15:50:18+08:00 Page Count : 2 Warning : Superfluous BOM at start of XMP XMP Toolkit : Adobe XMP Core 5.1.0-jc003 Format : application/pdf Producer : FREE PDFill PDF and Image Writer Creator Tool : PScript5.dll Version 5.2.2 Title : Microsoft Word - WT530T,WT530R_instruction manual_170803_.doc Creator : userEXIF Metadata provided by EXIF.tools