World Excel ZN020TC15 Wireless Zone thermostat User Manual WT830 ZN020 TC IM 150616

World Excel Company Ltd Wireless Zone thermostat WT830 ZN020 TC IM 150616

User Manual

 WT830 and ZN020 Wireless Zone Thermostat Instruction Manual                        Warning:    Changes or modifications to this unit not expressly approved by the party   responsible for compliance could void the user’s authority to operate the equipment.    NOTE:    This equipment has been tested and found to comply with the limits for a Class   B digital device, pursuant to Part 15 of the FCC Rules.   These limits are designed to   provide reasonable protection against harmful interference in a residential installation.     This equipment generates, uses and can radiate radio frequency energy and, if not   installed and used in accordance with the instructions, may cause harmful interference   to radio communications.      However, there is no guarantee that interference will not occur in a particular   installation.    If this equipment does cause harmful interference to radio or television   reception, which can be determined by turning the equipment off and on, the user is   encouraged to try to correct the interference by one or more of the following measures:    Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.      Room Sensor unit installation  Installation Location   The room sensor should be mounted on an inner wall ~1.5m above the floor in a position where it is readily affected by changes of the general room temperature with freely circulating air.    Opening the Cover Pull out the battery drawer and use a screwdriver to press on the spot shown below in order to detach the front shell from its base as shown in the below Figure.  Mounting Ensure that the surface is level. Drilling 2 holes at wall and fix the wall anchor. Fasten the thermostat with 2 pcs of long screws through the 2 mounting holes.    Insert two fresh AAA alkaline batteries into the drawer according to the polarity marked inside, then slide the drawer back into the place as shown in the above Figure.         Zone output unit installation Mounting ZN020 can be mounted on Din rail or mounted on wall directly Drilling 2 holes at wall and fix the wall anchor. Fasten the Zone output unit with 2 pcs screws at top housing.  Wiring connection Wiring power and device according to the label R  24Vac input C  24Vac common input Z1  Zone 1 dry contact Z2  Zone 2 dry contact Z3  Zone 3 dry contact Z4  Zone 4 dry contact      All damper outputs are dry contact  Add Room sensor to Zone output unit   1. Use dip switch to select system option Pole  Selection 1  RF channel address 1 2  RF channel address 2 3  RF channel address 3 4  RF channel address 4 5  Reserved 6  Reserved  2. Select any combination of RF channel from pole 1st to 4th   3. Power up ZN020 with 24Vac 4. Press and hold <SW1> button to enter add/drop mode Release button until all LED flashing 5. Power up Room sensor unit, the room sensor should be not added or finished dropping.  If there are any display or functional errors, please remove the batteries for about 30 sec to reset the thermostat.
6. Room sensor display “no C” when it is not connected    7. Press Up /Down to select Zone area 1 to Zone area 4 Please select Area 1 for the first adding.   8. Press SET to confirm, room unit will search the Zone output unit  9. LCD shows “done” and the zone area, press Next for initial internal setting.   10. Repeat step 4 to 9 for other Room unit  On/ Off mode   User can press <MODE> key to select OFF or ON mode  OFF mode:   Zone damper will be off and Room unit only display room temperature, set point cannot be changed in this mode  On mode: HEAT will be activated, this is based on the operation mode setting in Area 1 room unit  Room unit display the set point value at the top left corner  User can press up/down to change set point.       When user enter setting mode, room unit display SETTING icon. The top left corner value will be room temperature.  Press <SET> key to confirm the changes and back to normal page  Press<ENT> key back to normal page without changing set point     Internal Setting  Hold <SET> Key to enter internal setting mode  Press <Up/Down> to select C scale of F scale  Press <SET> to confirm        Press Up/Down to select heater delay time.  Sdy: 10 seconds Ldy: 3 minutes  If selected Ldy and heater is off, damper output cannot be turned on within 3 minutes.  Press SET to confirm      Press Up/Down to select the span 1oC(2oF) or 2oC(4oF)  Press SET to confirm and back to normal mode      Drop Room sensor from Zone output unit  1. Press and hold SW1 button to enter add/drop mode Release button until all LED flashing  2. Press<MODE> and <SET> key to enter drop mode  3. Press <SET> to confirm    Press<ENT> to cancel and exit drop mode
4. Room unit display “done” and “no c” after finish the dropping   5. Press “Next”, the room unit is ready for adding       Specification:  Room unit sensor Input Voltage:      3Vdc, 2* 1.5V AAA alkaline batteries Transmit Frequency:      918-924MHz Operating Temperature:   32 – 122 °F / 0 – 50 °C Storage Temperature:    23 – 140 °F / -5 – 60 °C Operating Humidity:    5-95% RH non-condensing Temperature Accuracy:   +/- 1 °F / 0.5 °C  Zone output unit:   Input Voltage:        24Vac +/- 20% Relay Contact Voltage:    24 Vac +/-20% Rated Current:      24Vac,1A    (each output) Terminals:        18-24AWG Transmit Frequency:      918-924MHz Operating Temperature:   32 – 122 °F / 0 – 50 °C Storage Temperature:    23 – 140 °F / -5 – 60 °C Operating Humidity:    5-95% RH non-condensing

Navigation menu