X Z LAB 113 IoT-Cloud User Manual

X-Z LAB, INC. IoT-Cloud Users Manual

Users Manual

IoT-Cloud
Users Manual
CONTENT
1.Introduction ................................................................................................................................... 3
2. specifications ................................................................................................................................. 3
3. Quick Installation........................................................................................................................... 4
4.Electromagnetic Compatibility ....................................................................................................... 4
5.Safety.............................................................................................................................................. 5
6.Trouble shooting ............................................................................................................................. 6
7. The package contain ...................................................................................................................... 7
1.Introduction
IoT-Cloud IOT-Ethernet transformer is meant to establish and maintain the entire radiation
detection system(Radsys), and it is the communication junction station between IOT and
Ethernet . It plays an important role in the Radsys system.
2. specifications
Specifications The IoT-Cloud
Rated voltage 5V-DC
Rated current 100mA
Wireless operation frequency 2405MHz-2475MHz
Wireless transmission power 19dBm
Power interface 5.5*2.1mm DC port
Data interface RJ45
Power adapter input voltage 100~220V /AC
Power adapter output voltage 5V/DC
Load capability 1A
Temperature -10-60
Dimensions 140*120*30mm
Weight 174g
Regulatory FCC Part 15 compliant
3. Quick Installation
1. Connect one end of the network cable to the RJ45 interface in the back of the IoT-Cloud;
2. Connect another end of the network cable to the PC port of the monitoring server, or the
router which is well connected with the server;
3. Fix the rod antenna in the SMA port in the back of the IoT-Cloud;
4. During installation, keep the device away from metal material which may effects the signal
quality;
5. Power on the IoT-Cloud through the adapter with the voltage range from 100V to 220V AC,
the power light will turn red when the device starts to work.
4.Electromagnetic Compatibility
This product complies with relevant international and national laws and standards on EMC
(electromagnetic compatibility) for this type of product when used as intended. Such laws and
standards define both the permissible electromagnetic emission levels from equipment and its
required immunity to electromagnetic interference from external sources.
Other electronic products exceeding the limits defined in such EMC standards could, under
unusual circumstances, affect the operation of the product.
• Information Technology Equipment (ITE) need special precautions regarding EMC, and need to
be installed and put into service according to EMC information provided in the accompanying
documents.
• Please use the shielding RJ 45 port which is meant to connect with PC, the use of accessories
and cables other than those specified may result in increased emission or decreased immunity
levels.
• The product should not be used adjacent to or stacked with other products and that if adjacent
or stacked use is necessary, it should be observed to verify normal operation.
This equipment is intended for use in a hospital environment. Operation in other than hospital
environments may compromise electromagnetic compatibility.
The IoT-Cloud complies with part 15 of the FCC Rules. Operation is subject to the following
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications to the equipment not expressly approved by the party responsible for
compliance could void the users authority to operate the equipment.
RF Exposure Requirement
To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter
must be installed to provide a separation distance of at least 20cm from all persons and must not
be co-located or operating in conjunction with any other antenna or transmitter.
5.Safety
Important safety directions
If the product is not functioning correct or damage is visible, please contact your RAYCAN
representative, who will take appropriate actions in order not to create harm. Handle the
product with care. Make sure that the product is used and stored in a secured environment to
prevent unauthorized access.
Maintenance & faults
WARNING Do not use the product for any application until you are sure that the user
routine-checks have been satisfactorily completed, and that the periodic maintenance of the
product is up to date. If any part of the product is known (or suspected) to be defective or
wrongly adjusted, DO NOT USE the product until a repair has been made. Operation of the
product with defective or wrongly adjusted components could expose the user or the patient to
radiation or other safety hazards. This could lead to fatal or other serious personal injury.
Safety awareness
WARNING Do not use the product for any application until you have read, understood and know
all the safety information, safety procedures and emergency procedures contained in this Safety
section. Operation of the product without a proper awareness of how to use it safely could lead
to fatal or other serious personal injury.
Adequate training
WARNING Do not use the product for any application until you have received adequate and
proper training in its safe and effective operation. If you are unsure of your ability to operate this
product safely and effectively, DO NOT USE IT. Operation of this product without proper and
adequate training could lead to fatal or other serious personal injury.
Safety devices
Warning Never attempt to remove, modify, override or frustrate any safety device on the
product. Interfering with safety devices could lead to fatal or other serious personal injury.
Intended use and compatibility
Warning Do not use the product for any purpose other than those for which it is intended. Do
not use the product with products other than that which RAYCAN recognizes as compatible.
Operation of the product for unintended purposes, or with incompatible products, could lead to
fatal or other serious injury.
Electrical safety
WARNING Do not remove covers or cables from this product. Dangerous electrical voltages are
present within this product. Removing covers or cables could lead to serious or fatal personal
injury. Covers or cables should only be removed by qualified and authorized service personnel.
Use this product in rooms or areas that comply with all applicable laws (or regulations having the
force of law) concerning electrical safety for this type of product. Electrically isolate this product
from the mains electrical supply before cleaning, disinfecting or sterilizing it.
Mechanical safety
WARNING Do not remove covers from this product. Removing covers could lead to serious or
fatal personal injury. Covers should only be removed by qualified and authorized service
personnel. In this context, qualified means those legally permitted to work on this type of
medical electrical product in the jurisdiction(s) in which the product is being used, and
authorized means those authorized by the user of the product.
Explosion safety
WARNING Do not use this product in the presence of explosive gases or vapors.
WARNING Do not use flammable or potentially explosive disinfecting sprays.
WARNING Use of this product in an environment for which it was not designed can lead to fire or
explosion.
Fire safety
Use of electrical product in an environment for which it was not designed can lead to fire or
explosion. Fire regulations for the type of medical area being used should be fully applied,
observed and enforced. Fire extinguishers should be available for both electrical and
non-electrical fires.
WARNING Only use extinguishers on electrical or chemical fires, which are specifically labeled for
those purposes. Using water or other liquids on an electrical fire can lead to fatal or other serious
personal injury. If it is safe to do so, attempt to isolate the product from electrical and other
supplies before attempting to fight a fire. This will reduce the risk of electric shocks.
Electrostatic discharge (ESD)
CAUTION Always wait at least ten seconds after the product is switched OFF before switching the
product back to ON.
CAUTION Always use proper static procedures, protection, and product prior to opening and
during handling of this product. This product contains components that are electrostatic
sensitive. Failure to use ESD procedures may cause damage to these components. Such damage
to components is not covered by RAYCAN warranties.
ESD can amount to a significant voltage, which may cause damage to PCBs or other system
components.
ESD damage is cumulative and may not be apparent at first, as indicated by a hard failure, but
can cause degraded performance. Therefore, always use proper ESD handling procedures. ESD
can result from low humidity conditions, use of electrical equipment on carpeting, linens, and
clothing.
6.Trouble shooting
Problems Solutions
Unable to connect correctly Restart and check the connection.
* If the problem listed
above can’t be solved, please
contact us
7. The package contain
Name Number
Host 1
Rod Antenna 1
Power Adapter 1
Certificate 1
Users manual 1
Branch office
2440 Camino Ramon, Suite 264
San Ramon, CA 94583,USA
Headquarters
Bldg 17, 8 Jinfeng Rd, Suzhou New
District, Suzhou, 215163, China
1-925-359-6908 (T)
1-925-380-6784 (F)
Web: http://www.x
-
zlab.com/
Version:H-2-000001

Navigation menu