X Z LAB SI-BDM-2250 Digital PET detector User Manual

X-Z LAB, INC. Digital PET detector

User Manual

 Si-BDM-2250  USER MANUAL
CONTENT  1. Introduction ........................................................................................... 3 2. Specifications ........................................................................................ 3 3. Operate Guide ....................................................................................... 5 4. Electromagnetic Compatibility ............................................................. 6 5. Safety .................................................................................................... 6 6. Trouble shooting ................................................................................... 8 7.The Package Contain ............................................................................. 9
1. Introduction Si-BDM-2250 is an all-digital, high performance detector module which can capture Gamma  photon’s  information,  digitalize  it  and  transfer  output  data  to  the  host computer. Si-BDM-2250 can be expediently applied as the basic module in design of position-emission  tomography.  With  its  dual-head  structure  and  prominent  timing performance, Si-BDM-2250 could also  play an important role in scientific research experiment.    2. Specifications Detector Blocks Constitution LYSO crystal array  +  Silicon Photomultiplier (SiPM) Crystal Pixel Size 3.8x3.8x20mm3(20mm as height) Radiation Type 511KeV Gamma photon Energy Resolution 15%@511KeV Timing Resolution 550ps@[450~650] KeV Detector module Number of Detector Blocks 2 Number of Channels 72 Dimension 205×99.5×14.8 mm3(The top surface designed in camber angle, the height varies from 14.8 to 25 ) Weight 577g    (189 g for Detector Blocks ) Power adapter input voltage 100~240V /AC, 50/60Hz Power Consumption 10.5W Data Interface RJ45 Operating Environment
Temperature Room temperature Humidity 30%~80% Atmospheric Pressure 700hpa~1060hpa Regulatory FCC Part 15 compliant
3. Operate Guide  1. Plug one end of Gigabit Ethernet cable into the RJ45 interface in the detector module, connect another end of this cable to host computer or router; 2. Connect  the  detector  module  and  global  clock  board  with  an  clock  signal wire ; 3. Connect the detector module and host computer with an Micro-USB to UART wire, and this USB port was used to debug the software by professionals. 4. Connect the  power adapter  and tight  the bolt  of junction.  The voltage  input ranges from 100V to 240V AC; 5. Turn on the power and configure digitalize parameters on host computer by using the software packed; 6. Acquire the output data on host computer. During the module operation, keep the detector blocks in light-proof situation.
4. Electromagnetic Compatibility This product complies with relevant international and national laws and standards on EMC (electromagnetic compatibility) for this type of product when used as intended. Such laws and standards define both the permissible electromagnetic emission levels from  equipment  and  its  required  immunity  to  electromagnetic  interference  from external sources. Other electronic products exceeding the limits defined in such EMC standards could, under unusual circumstances, affect the operation of the product.   • Information Technology Equipment (ITE) need special precautions regarding EMC, and need to be installed and put into service according to EMC information provided in the accompanying documents.   • Please use the shielding RJ45 port which is meant to connect with PC, the use of accessories and cables other than those specified may result in increased emission or decreased immunity levels.   • The product should not be used adjacent to or stacked with other products and that if adjacent or stacked use is necessary, it should be observed to verify normal operation.   This equipment is intended for use in a hospital environment. Operation in other than hospital environments may compromise electromagnetic compatibility.      The Si-BDM-2250 complies with part 15 of the FCC Rules. Operation is subject to the following conditions:       (1)    This device may not cause harmful interference, and (2) this device must accept  any  interference  received,  including  interference  that  may  cause undesired operation.      Changes  or  modifications  to  the  equipment  not  expressly  approved  by  the  party responsible for compliance could void the user’s authority to operate the equipment. 5. Safety Important safety directions   If  the  product  is  not  functioning  correct  or  damage  is  visible,  please  contact  your       RAYCAN  representative,  who  will  take  appropriate  actions  in  order  not  to  create harm. Handle the product with care. Make sure that the product is used and stored in a secured environment to prevent unauthorized access.   Maintenance & faults   WARNING Do not use the product for any application until you are sure that the user   routine ‐checks  have  been  satisfactorily  completed,  and  that  the  periodic maintenance  of  the  product  is  up  to  date.  If  any  part  of  the  product  is  known  (or suspected)  to  be  defective  or  wrongly  adjusted,  DO NOT  USE  the  product  until  a repair has been made. Operation of the product with defective or  wrongly adjusted
components could expose the user or the patient to radiation or other safety hazards. This could lead to fatal or other serious personal injury.   Safety awareness   WARNING  Do  not  use  the  product  for  any  application  until  you  have  read, understood  and  know  all  the  safety  information,  safety  procedures  and  emergency procedures contained in this Safety section. Operation of the product without a proper awareness of how to use it safely could lead to fatal or other serious personal injury.   Adequate training   WARNING  Do  not  use  the  product  for  any  application  until  you  have  received adequate and proper training in its safe and effective operation. If you are unsure of your  ability  to  operate  this  product  safely  and  effectively,  DO  NOT  USE  IT. Operation of this product without proper and adequate training could lead to fatal or other serious personal injury.   Safety devices   WARNING Never attempt to remove, modify, override or frustrate any safety device on  the  product.  Interfering  with  safety  devices  could  lead  to  fatal  or  other  serious personal injury.   Intended use and compatibility       Warning  Do  not  use  the  product  for  any  purpose  other  than  those  for  which  it  is intended.  Do  not  use  the  product  with  products  other  than  that  which  RAYCAN recognizes as compatible.   Operation  of  the  product  for  unintended  purposes,  or  with  incompatible  products, could lead to fatal or other serious injury.   Electrical safety   WARNING Do not remove covers or cables from this product. Dangerous electrical voltages  are  present  within  this  product.  Removing  covers  or  cables  could  lead  to serious or fatal personal injury. Covers or cables should only be removed by qualified and authorized service personnel.   Use this product in rooms or areas that comply with all applicable laws (or regulations having  the  force  of  law)  concerning  electrical  safety  for  this  type  of  product. Electrically  isolate  this  product  from  the  mains  electrical  supply  before  cleaning, disinfecting or sterilizing it.   Mechanical safety   WARNING Do not remove covers from this product. Removing covers could lead to serious  or  fatal  personal  injury.  Covers  should  only  be  removed  by  qualified  and authorized service personnel. In this context, qualified means those legally permitted to work on this type of medical electrical product in the jurisdiction(s) in which the product  is  being  used,  and  authorized  means  those  authorized  by  the  user  of  the product.   Explosion safety   WARNING Do not use this product in the presence of explosive gases or vapors.   WARNING Do not use flammable or potentially explosive disinfecting sprays.   WARNING Use of this product in an environment for which it was not designed can lead to fire or explosion.
Fire safety   Use of electrical product in an environment for which it was not designed can lead to fire or explosion. Fire regulations for the type of medical area being used should be fully applied, observed and enforced. Fire extinguishers should be available for both electrical and non‐electrical fires.   WARNING  Only  use  extinguishers  on  electrical  or  chemical  fires,  which  are specifically labeled for those purposes. Using water or other liquids on an electrical fire can lead to fatal or other serious personal injury. If it is safe to do so, attempt to isolate the product from electrical and other supplies before attempting to fight a fire. This will reduce the risk of electric shocks.   Electrostatic discharge (ESD)   CAUTION Always wait at least ten seconds after the product is switched OFF before switching the product back to ON.   CAUTION  Always  use  proper  static  procedures,  protection,  and  product  prior  to opening and during handling of this product. This product contains components that are electrostatic sensitive. Failure to use ESD procedures may cause damage to these components. Such damage to components is not covered by RAYCAN warranties.   ESD can amount to a significant voltage, which may cause damage to PCBs or other system components.   ESD damage is cumulative and may not be apparent at first, as indicated by a hard failure,  but  can  cause  degraded  performance.  Therefore,  always  use  proper  ESD handling procedures. ESD can result from low humidity conditions, use of electrical equipment on carpeting, linens, and clothing.   6. Trouble shooting Problems Solutions The yellow and green LEDs on RJ45 interface don’t shine Check Gigabit Ethernet cable connection situation No data acquired in host computer Confirm that detector blocks stay in light-proof situation and reset global clock board *        If the problem listed above can’t be solved, please contact us
7. The Package Contain Name Number Power adaptor 1 Global clock board   1 Clock signal wire 1 Gigabit Ethernet cable 1 Configure Software 1 Micro-USB to UART wire 1 User Manual 1   Federal Communications Commission (FCC) Interference Statement  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generate, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:    Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is    connected.   Consult the dealer or an experienced radio/TV technician for help.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)  This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
                                                              Branch Office                2440 Camino Ramon, Suite 264                                     San Ramon, CA 94583, USA                Headquarters                Bldg 17, 8 Jinfeng Rd, Suzhou New                    District, Suzhou, 215163, China                                   1-925-359-6908 (T)                    1-925-380-6784 (F)                    Web: http://www.x-zlab.com/

Navigation menu