YDI Wireless MB-49-HP Point to Point Wireless Bridge User Manual Marquee Bridge 4 9 vED2
YDI Wireless Point to Point Wireless Bridge Marquee Bridge 4 9 vED2
Manual
PRELIMINARY Introduction Marquee™ P2P Bridge Quick Start Guide Figure 2 – Detail Showing Outdoor Unit Pole Mount Bracket The Marquee P2P Bridge (MB-49) is a complete 4.9 GHz wireless point-to-point (p-p) or point-to-multipoint (p-mp) system that links two Ethernet LANs together. It consists of two high-gain directional antennas and a pair of OFDM radios in a rugged outdoor enclosure. They connect to the LAN's Ethernet Switch on each end with an outdoor-rated Ethernet cable ordered separately. It is ideal for connecting two office LANs together, or for linking a WIPOP site to an Internet backbone. The Marquee P2P Bridge uses TurboCell software which supports VLAN bridging (802.1q protocol). The Marquee P2P Bridge will accommodate virtually an unlimited number of client MAC addresses on each side of the link. The unit currently supports a single channel. Marquee P2P Bridge Kit Contents 1. 2. 3. 4. 5. 6. Two outdoor radios with RF connector for external antenna and mounting hardware Two Cat 5 DC Power Injectors (surge protected Power Injectors are available as an option) Two 110/240 VAC to 48 VDC power supplies Windows -based YDI Configurator software Two 3 foot low-loss coaxial cables Two high-gain directional antennas 2. Align the four mounting studs on the outdoor unit with the bracket holes (see Figure 3) and secure to the bracket by pushing down the latches as shown in Figures 4a and 4b. Figure 3 – Attaching the Marquee P2P Bridge Outdoor Unit to the Pole Mount Bracket YDI EtherAnt outdoor Ethernet cables must be ordered separately. Available lengths are 50, 100, 200, or 300 ft. Figure 1 – Marquee P2P Bridge Kit Contents The Marquee P2P Bridge is intended for professional installation only on fixed outdoor structures. Please review the entire manual before powering up or deploying these units. Figure 4a – Latching Bracket to Pole Mount Installation NOTE: All connectors must be properly water-proofed with all-weather electrical tape, Permagum, or equivalent. Do not use Silicon glue. The Marquee P2P Bridge radio unit is installed by means of a pole mount adaptor bracket that is secured to the pole using two metal hose type clamps. Figure 1 shows the hardware provided to mount the outdoor RF Unit. 1. Install the outdoor unit pole mount adaptor bracket using the supplied metal hose type clamps (see Figure 2). MNL-500267-001 – Rev ED2 Aug 2004 Marquee™ P2P Bridge Quick Start Guide PRELIMINARY Figure 4b – Securing the Latches to the Pole Mount Bracket Figure 6 – Plugging the Round Connector 4. 3. Ensuring that there is no DC power applied to the DC Power Injector, plug the round connector of the outdoor Ethernet cable into the rear jack of the unit (Fig. 5), making sure the notch is correctly aligned with the tab on the jack as shown in Figure 6, then turn the round locking nut clockwise as you push in until it securely fastens onto the jack. Attach the other end of the outdoor Ethernet cable to the Cat 5 DC Power Injector at port RJ-45 labeled “To ANT.” NOTE: The Cat 5 DC Power Injector is not in a waterproof enclosure and must be protected from the weather. It can be permanently mounted to a surface using the double stick tape found on the back of it. WARNING: Please verify that the round connector is properly plugged into the rear jack of the antenna prior to connecting DC power because it is possible to push it in the wrong way if enough force is used. If DC Power is applied while you are attempting to insert the round connector into the jack, it is possible that, as you rotate the plug in an effort to find the key, DC power pins will momentarily touch the Ethernet pins. If this happens the Ethernet circuitry on the board will be damaged. Any harm caused by this action will not be covered by the factory warranty and will be a billable repair. Figure 5 – Connecting the Outdoor Ethernet Cable 5. Connect the Ethernet cable labeled “To PC or Router” from the Cat 5 DC Power Injector to your router, switch or hub. If you connect to a computer or PC, a crossover cable or adapter will be needed. 6. If your unit is placed on a non-metal pole or structure, install a #6 AWG insulated ground cable (not provided) to the ground connector in the back of the radio as shown in Figure 7. Use a selfthreading screw and a flat washer to fasten the earth lug. This provides safeguard against lightning. For maximum protection, YDI also recommends the use of its optional surge protected DC Injector available from your YDI dealer (part No. 304800620-002). This DC Injector has an additional wire to be connected to ground as shown on Fig. 8. Figure 7 – Detail Showing Ground Cable Connection (this provides maximum lightning protection) Plug Round Connector of the Outdoor Ethernet Cable Here Aug 2004 MNL-500267-001 – Rev ED2 PRELIMINARY Marquee™ P2P Bridge Quick Start Guide Installing the Management Software Figure 8 – Installation of the Optional YDI Surge Protected DC Injector The Windows -based YDI Configurator software can be installed on a PC or workstation running Windows 98/ME, 2000, NT, or XP. This software has a GUI (Graphical User Interface), which makes it easy to use. The program allows you to locally or remotely perform the following procedures: Ground Wire AC Power Power Supply RJ-45 Ethernet Connector To Switch, Router or PC YDI Surge Protected DC Injector • • To Marquee • NOTE: The regular DC injector supplied with your kit is connected the same way but it does not have a ground wire 7. Display a list of units running on the local network Display and edit the current configuration of the units Save and load configurations IMPORTANT: Your Marquee P2P Bridge units must be on the same subnet as the computer with the YDI Configurator installed, or have a routable IP address, in order to access it. If not, you will get a status of Offline for the unit (see the Status column in Figure 10) even if the LEDs show activity. To configure the units, change the IP address of your computer to a 10.1.1.x sub-net. Once you have access to the unit, you can then assign a new IP address to it by clicking on the Setup tab and IP Host button. Plug the antenna coaxial cable into the N-type female connector of the unit as shown in Figure 9. Plug the AC Adapter into an AC outlet and connect it to the “DC Power” jack on the Cat 5 DC Power Injector. Perform antenna alignment procedures at both sites. Proper antenna alignment is crucial for the correct operation of the Marquee Bridge 49 system and should only be accomplished by experienced professionals. After that your installation is complete. Note that the YDI Configurator program is also used to manage AP-Plus units. Therefore you will see many grayed out options, features and settings. These only become available when you are connected to an APPlus, Orinoco AP, or router that has all these features available. WARNING: The P2P must be operated with a proper antenna or microwave terminator plugged into the N-type female jack of the unit. Operating the unit with nothing connected to the antenna jack may result in damage to the TX section of the unit which will not be covered by the factory warranty and will be a billable repair. To install the YDI Configurator in Windows, insert the YDI CD-ROM included in the Marquee kit into the appropriate drive of your computer. Using your Windows Explorer, open the directory \Management Software\YDI Configurator and run the Set Up program (YDI Configurator vx.xx.exe). Simply follow the instructions on the screen which will guide you through the entire process. After completing the YDI Configurator installation, you are ready to set up your system. Figure 9 – Connecting the Antenna Coaxial Cable to the P2P Plug Antenna Coaxial Cable Here NOTE: For detailed information about the YDI Configurator, please refer to the online help, available by pressing F1 or clicking Help-> Index from the main screen. Configuring the Marquee P2P Bridge The Marquee P2P Bridge is shipped from factory preconfigured for bridging operation and with the proper transmit power settings. The two units are set with the following default IP addresses: LEDs The Green LED is steady on when power is applied (Figure 10). 10.1.1.10 and 10.1.1.11 Figure 10 – Marquee P2P Bridge LEDs The default read/write password is public. Green LED) Some of the parameters that you may need to change are the following: • MNL-500267-001 – Rev ED2 IP addresses Aug 2004 Marquee™ P2P Bridge Quick Start Guide PRELIMINARY • • Read/Write password Radio frequency channel 1. Connect a crossover Ethernet cable from the Cat 5 DC Power Injector to your computer or PC. 2. The installation process should have placed two new icons on your computer’s desktop: a Configurator icon and a PTP Configurator icon. The Configurator is the full-size version of the management program and is used for all type of configurations. The PMP Configurator is a compressed version of the program and is exclusively used for p-p configurations. Double click the Configurator icon. Alternatively, you may open the directory where the program has been installed (the default is \Program Files\Configurator) and run the program Config.exe. 3. The Main Screen shown in Figure 11 appears. To scan for devices on the network, place the cursor in the List of Scanned Devices text box and right-click the mouse. A Re-scan local network button will appear. Click on the button. A list of devices will appear. Figure 12 – Read/Write Password Screen Figure 13 – IP Setup Screen Figure 11 – YDI Configurator Main Screen Figure 14 – Interface Setup Screen 4. Click on the device you wish to configure. The selected device IP address will appear in the text box above the Configure Remote button (alternatively, you can enter the IP address of the Marquee Bridge 49 unit). Click this button. 5. A Read/Write Password text box will appear (see Figure 12). The default password is public. Click the OK button. It is suggested that you change the password later, write it down and keep it in a safe place. 6. After you login successfully, the Setup screen appears. Click on the IP Host button. The IP Setup screen appears (see Figure 13). Enter the IP Address, Subnet Mask, and Default Router IP Address. Click OK. Aug 2004 MNL-500267-001 – Rev ED2 PRELIMINARY Marquee™ P2P Bridge Quick Start Guide 7. On the Setup screen, click on the Interface Setup button. The corresponding screen appears (see Figure 14). 10. The Marquee P2P Bridge is optimized for a transmit rate of 36 Mbps and the transmit power is preset from factory with the proper value. 8. Click on Setup 2. The 802.11 Setup screen appears (see Figure 15). Select the type of Station this Marquee P2P Bridge is going to be. In a p-p configuration, one unit must be Base and the other must be Remote (Satellite). In a p-mp configuration, one unit must be Base and all the others must be Remote (Satellite). Radio Configuration must be set to 802.11a. The Base station should be set for Polling Base Station. Leave the rest of the buttons unchanged. NOTE: Make sure the output power is set to 50% when using a sector antenna. 11. Click OK. Click OK again. 12. Click the System Access button. The corresponding screen appears (see Figure 17). Enter a Pass Phrase to identify the wireless network. All units must be configured with the same value. Click OK. Figure 17 – System Access Setup Screen Figure 15 – 802.11 Setup Screen 9. 13. Go to File and click Save Config: this will save the new settings. Click the Advanced button. The corresponding screen appears (see Figure 16). Select a Frequency Channel from the pull down menu box. All units must be configured with the same value. 14. After the Marquee P2P Bridge is finished saving its configuration, exit the YDI Configurator program. The Marquee P2P Bridge is ready to use. Refer to the online help for complete instructions on setting up other features in the unit. Figure 16 – 802.11 Advanced Setup Screen MNL-500267-001 – Rev ED2 Aug 2004 Marquee™ P2P Bridge Quick Start Guide PRELIMINARY Technical Support FCC NOTICE Your primary source of assistance is the dealer from which you purchased this product. The YDI support staff should only be contacted directly if you purchased this product directly from YDI. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment when installed as directed. The equipment is intended for professional installation only on fixed outdoor structures, for p-p or p-mp operation in the 4.9 GHz licensed band. This equipment should be installed and operated such that there is a minimum of 2 meters of separation distance between the equipment and all persons during normal operation. If you are using a 4 ft dish antenna, the minimum separation distance must be 2.35 meters. NOTE: Before you contact Technical Support, please make sure that you have read and thoroughly understood all instructions outlined on this manual. YDI Wireless 8000 Lee Highway Falls Church, VA 22042 USA Tel.: 703-205-0600 Fax: 703-205-0610 E-mail: tech@ydi.com www.ydi.com The installer must avoid the main beam of the antenna and point it to locations not occupied by persons during the installation. The latest software and User’s Manuals can also be found at: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: http://www.ydi.com/support/downloads.php (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. http://www.ydi.com/support/documents.php NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. To see all our FCC certified systems, please visit: http://www.ydi.com/deployinfo/fcc-info.php Aug 2004 MNL-500267-001 – Rev ED2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 6 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a1b84894-8218-4d48-a276-63882d69bccd Producer : Acrobat PDFWriter 4.05 for Windows NT Create Date : 2004:08:27 11:04:44Z Creator Tool : Marquee Bridge 4.9 vED2.doc - Microsoft Word Modify Date : 2005:01:18 15:17:59-05:00 Metadata Date : 2005:01:18 15:17:59-05:00 Document ID : uuid:a4fe3f1f-99ef-456b-b246-c760d8ea5644 Format : application/pdf Title : Marquee Bridge 4.9 vED2.doc Creator : jose Author : joseEXIF Metadata provided by EXIF.tools