VX-4100 SERIES
OPERATING MANUAL
P1
TX/BUSY
P2
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
Congratulations!
You now have at your fingertips a valuable communications tool: a VERTEX STANDARD two-way radio! Rugged, reliable and easy to use, your VERTEX STANDARD
radio will keep you in constant touch with your colleagues for years to come, with
negligible maintenance downtime.
Please take a few minutes to read this manual carefully. The information presented
here will allow you to derive maximum performance from your radio, in case questions arise later on.
We’re glad you joined the VERTEX STANDARD team. Call on us anytime, because
communications is our business. Let us help you get your message across.
NOTICE !
There are no owner-serviceable parts inside the transceiver. All service jobs
must be referred to an authorized VERTEX STANDARD Service Representative. Consult your Authorized VERTEX STANDARD Dealer for installation of optional accessories.
SAFETY/WARNING INFORMATION
WARNING - DO NOT operate the VX-4100 radio when any person(s) (bystanders) outside the vehicle are within the distances shown in the chart at the
bottom of this section.
Safety Training information:
Antennas used for this transmitter must not exceed an antenna gain of 0 dBd.
The radio must be used in vehicle-mount configurations with a maximum operating duty factor not exceeding 50%, in typical Push-to-Talk configurations.
This radio is restricted to occupational use, work related operations only where
the radio operator must have the knowledge to control the exposure conditions of its passengers and bystanders by maintaining the minimum separation distance shown below.
Failure to observe these restrictions will result in exceeding the FCC RF exposure limits.
Antenna Installation:
For rear deck trunk installation, the antenna must be located at least the following distance away from rear-seat passengers in order to comply with the
FCC RF exposure requirements.
For roof top installations, the antenna must be placed in the center of the roof.
Unsafe Radiation Distance
VX-4101
1.97 Feet
(0.60 m)
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
INTRODUCTION
P1
TX/BUSY
P2
The VX-4100 Series are full-featured FM transceiver designed for flexible mobile
and base station business communications in the VHF or UHF Land Mobile bands.
These transceiver are designed for reliable business communications in a wide variety of applications with a wide range of operating capability provided by their leading-edge design.
Important channel frequency data is stored in EEPROM and flash memory on the
CPU, and is easily programmable by dealers using a personal computer and the VERTEX STANDARD VPL-1 Programming Cable and CE59 Software.
The pages which follow will detail the many advanced features provided on the VX4100 Series transceiver. After reading this manual, you may wish to consult with
your Network Administrator regarding precise details of the configuration of this
equipment for use in your application
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
CONTROLS & CONNECTORS
Front Panel
Important! - All buttons located on the Front Panel are Programmable Function (PF)
Buttons, configured according to your network requirements and programmed by
your VERTEX STANDARD dealer. The instructions below discribe a typically-configured radio.

P1
TX/BUSY
P2
 
 VOL Knob
Turn this control clockwise to increase the volume.
 Microphone Jack
Connect the microphone plug to this jack.
 Emergency Microphone
The emergency microphone is located behind this small slit. When the emergency feature is activated, this microphone is enabled.
 [MON], [A], [] Buttons (Programmable Function Buttons)
These buttons can be set up for special applications, such as High/Low power
selection, Monitor, Talk-Around, etc., as determined by your network requirements and programmed by your VERTEX STANDARD dealer.
(POWER) Button
Press and hold in this button for 2 seconds to toggle the transceiver’s power “on”
and “off.”
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
CONTROLS & CONNECTORS
 TX/BUSY Indicator
Indicates the transceiver’s Transmit/Receive Status.
Steady Red:
Transmitting in progress
Steady Green: Signaling Off
Blinking Green: Busy Channel/Squelch Off
 Channel Number Indicator
Indicates the operating channel.
 Transceiver Status Indicator
The “P1” and “P2” indicators show current transceiver status, which can be
customized via programming by your VERTEX STANDARD dealer to meet
your communications/network requirements. The possible “P1” and “P2” displays are explained below.
STATUS
MONI
SCAN Channel
+4 CH
LOW
TA (Talk Around)
Encryption Disable
(Requires optional Unit)
Emergency
HOME
Horn Alert
Public Adress
Key Lock
EXT ACC
REC/PLAY
INDICATOR
P1
P2
DESCRIPTION
This indicator blinks when CTCSS- or DCScontrolled squelch is disabled. The indicator is
Illuminated constantly while the audio is passing normally.
Illuminates the indicator when the operating
channel is selected on the SCAN channel.
Illuminates the indicator when the radio recalls
the alternate channel list.
Illuminates the indicator when the radio’s transmitter is set to the “Low Power” mode.
Illuminates the indicator when the “Talk Around”
function is activated.
Illuminates the indicator when the “Voice
Scrambler” function is disabled temporarily.
Illuminates the indicator when the “Emergency”
feature is activated.
Illuminates the indicator when you recall the
Home group/channel.
Illuminates the indicator when the “Horn Alert”
feature is activated.
Illuminates the indicator when the radio is
turned to a PA amplifier.
Illuminates the indicator when the front panel’s
keys are locked.
Illuminates the indicator when the output port
on the Accessory Connector is turned to “ON.”
Blinks the indicator while the received audio is
recording. Illuminates the indicator when the
voice recording is completed.
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
CONTROLS & CONNECTORS
Rear Panel
 
 13.6V DC Cable Pigtail with Connector
The supplied DC power cable must be connected to this 2-pin connector. Use
only the supplied fused cable, extended if necessary, for power connection.
 Antenna Socket
The 50-Ohm coaxial feedline to the antenna must be connected here, using a
type-M (PL-259) plug.
 D-Sub 15-Pin Accessory Connector
External TX audio line input, PTT (Push To Talk), Squelch, and external RX
audio line output signals may be obtained from this connector for use with accessories such as data transmission/reception modems, and external Channel control input etc.
 External Speaker Jack
An external loudspeaker may be connected to this 2-contact, 3.5-mm mini-phone
jack.
Caution: Do not connect either wire of this line to ground, and be certain that the
speaker has adequate capability to handle the audio output (12 W) from the
radio.
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
BASIC OPERATION OF THE TRANSCEIVER
Important! - Before turning on the radio the first time, confirm that the power connections have been made correctly and that a proper antenna is connected to the
antenna jack.
Switching Power ON/OFF
(POWER) button to turn the radio on. The display will become
 Press the
illuminated.
 Press the PF (Programmable Function) button which is programmed to the Channel Up/Down feature to choose the desired operating channel. A channel number
will be displayed. See page 7 for more information on the Programmable Function keys.
Setting the Volume
 Turn the VOL knob clockwise to increase the volume, and counterclockwise to
decrease it.
Transmitting
 To transmit, monitor the channel and make sure it is clear.
THIS IS AN FCC REQUIRMENT!
 Press the PF button which is programmed to the Monitor feature to listen for
channel activity.
 When receiving a call, transmit only after the incoming call ends. The radio
cannot receive a call and transmit simultaneously.
 Press the PTT switch.
 If the channel is clear, the BUSY/TX indicator will glow red. The radio is now
transmitting. While holding in the PTT switch, speak across the face of the microphone in a clear and normal voice. For best transmission, hold the microphone about 1-1/2 to 2 inches away from your mouth. Release the PTT switch to
receive.
 If the Busy Channel Lockout feature has been programmed on a channel, the
radio will not transmit when a carrier is present. Instead, the radio will generate
a short beep three times. Release the PTT switch and wait for the channel to be
clear of activity.
 If CTCSS or Digital Coded Squelch (DCS) Lockout has been programmed on a
channel, the radio can transmit only when there is no carrier being received or
when the carrier being received includes the correct CTCSS tone or DCS code.
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
BASIC OPERATION OF THE TRANSCEIVER
Automatic Time-Out Timer
If the selected channel has been programmed for automatic time-out, you must limit
the length of each transmission. While transmitting, a beep will sound 10 seconds
before time-out. Another beep will sound just before the deadline; the red “TX”
indicator will disappear and transmission will cease soon thereafter. To resume transmitting, you must release the PTT switch and wait for the “penalty timer” to expire
(if you press the PTT switch before this timer expires, the timer restarts, and you will
have to wait another “penalty” period)
Key Lock
In order to prevent accidental frequency change or inadvertent transmission, various
aspects of the VX-4100’s keys, and the PTT switch, may be locked out. The precise
lockout configuration must be programmed by your VERTEX STANDARD dealer
To activate the Locking feature, press and hold in the [A] key while turning the radio
on. To disable the Locking feature, repeat this power-on procedure.
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
Programmable Function (PF) Buttons
The VX-4100 Series includes seven Programmable Function (PF) Buttons. The PF
button functions can be customized, via programming by your VERTEX STANDARD dealer, to meet your communications/network requirements. Some features
may require the purchase and installation of optional internal accessories. The possible PF button programming features are illustrated below, and these functions are
explained on the pages to follow.
For further details, contact your VERTEX STANDARD dealer. For future reference,
check the box next to the function that has been assigned to each PF button on your
particular radio, and keep it handy.
Function
MONI
Channel Up
Channel Down
SCAN
DW (Dual Watch)
Follow-Me SCAN
Follow-Me DW
LOW
TA (Talk Around)
Encryption Disable
Emergency
CALL/RESET
PF Button
MON A
Function
PF Button
MON A
CALL 1 to Call 5
HOME
Horn Alert
Public Address
EXT. ACC1
EXT. ACC2
Direct CH#1
Direct CH#2
Direct CH#3
Direct CH#4
REC/PLAY
: Requires optional unit
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
Description of Operating Functions
MONITOR (MONI)
Press the assigned programmable key to cancel CTCSS- and DCS-controlled squelch;
the BUSY/TX indicator will blink green. Press and hold in this button for 1.5 seconds to hear background noise (unmute the audio); the BUSY/TX indicator will
glow green.
CHANNEL UP/DOWN
Press the assigned programmable key to select a different channel.
CHANNEL SCAN (SCAN)
The Scanning feature is used to monitor multiple channels programmed into the transceiver. While scanning, the transceiver will check each channel for the presence of a
signal, and will stop on a channel if a signal is present.
To activate scanning:
 Press the assigned programmable key to activate scanning.
 The scanner will search the programmed channels, looking for active ones; it
will pause each time it finds a channel on which someone is speaking.
 Press the assigned programmable key again to disable scanning. Operation will
revert to the programmed revert channel.
Note: Your dealer may have programmed your radio to stay on one of the following channels if you press the PTT switch during the scanning pause:
 Current channel (“Talk Back”)
 “Last Busy” channel
 “Priority” channel
 “Home” channel
 “Scan Start” channel
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
DUAL WATCH (DW)
The Dual Watch feature is similar to the SCAN feature, except that only two channels
are monitored:
 The current operating channel; and
 The Priority channel.
To activate Dual Watch:
 Press the assigned programmable key.
 The scanner will search the two channels; it will pause each time it finds a
channel on which someone is speaking.
To stop Dual Watch:
 Press the assigned programmable key.
 Operation will revert to the “Dual Watch Start” channel.
FOLLOW-ME SCAN
“Follow-Me” Scan feature checks a User-assigned Priority Channel regularly as you
scan the other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available channels) are designated for “Scanning,” the user may nonetheless assign Channel 2 as
the “User-assigned” Priority Channel via the “Follow-Me” feature.
To activate “Follow-Me” scanning, first select the channel you want to designate as
the “User-Assigned Priority Channel” and press the assigned programmable key.
Then press the Channel Up/Down key to recall to the “Scanning Start” channel which
has been programmed by your dealer to activate the scanner. When the scanner stops
on an “Active” channel, the User-assigned Priority Channel will automatically be
checked every few seconds; if activity is found on the User-assigned Priority Channel, the radio will switch between it and the Dealer-Assigned Priority Channel, if
any.
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
FOLLOW-ME DUAL WATCH (DW)
To set up a “Dual Watch” frequency pair using the “Follow-Me” feature, select a
channel using the Channel Up/Down key. Now press the assigned programmable
key; pressing the assigned programmable key locks the current channel as the Userassigned Priority Channel. Now press the Channel Up/Down key to select another
channel (not the “Scanning Start” channel). Your radio will now switch back-andforth between the currently-selected channel and the User-assigned Priority Channel.
During “Follow-Me” scanning (after you have pressed the key), you can set up the
“Dual Watch” feature by pressing the Channel Up/Down key to another channel. The
radio will then scan back and forth between the original User-assigned Priority Channel
and the newly-selected channel.
The Priority Channel you have assigned (before pressing the key) will be retained in
memory until you change it.
LOW POWER (LOW)
Press the assigned programmable key to set the radio’s transmitter to the “Low Power”
mode, thus extending battery life. Press the key again to return to “High Power”
operation when in difficult terrain.
TALK AROUND (TA)
Press the assigned programmable key to activate the Talk Around feature when you
are operating on duplex channel systems (separate receive and transmit frequencies,
utilizing a “repeater” station). The Talk Around feature allows you to bypass the
repeater station and talk directly to a station that is nearby. This feature has no effect
when you are operating on “simplex” channels, where the receive and transmit frequencies are already the same.
Note that your dealer may have mode provision for “Talk Around” channels by programming “repeater” and “Talk Around” frequencies on two adjacent channels. If so,
the key may be used for one of the other Pre-Programmed Functions.
ENCRYPTION DISABLE (OPTION)
When the Voice Scrambler feature is enabled, press the assigned programmable key
to toggle the voice encryption on and off.
10
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
EMERGENCY
The VX-4100 series include an “Emergency” feature which may be useful if you
have someone monitoring on the same frequency as your transceiver’s channel.
Press the assigned programmable key to initiate an emergency call. For further details contact your VERTEX STANDARD dealer.
CALL/RESET
This feature, if enabled, allows the user to change the 3-digit Page Call code, used to
call other similarly-equipped stations. Press the assigned programmable key, followed by the three digits representing the Page Call code of the station you wish to
call. Three tones will be heard after the last key is pressed (the new code will now be
transmitted).
The receiver squelch of the other station will be opened, and you can begin communication.
CALL 1 TO CALL 5
Press the assigned programmable key to send a 5-Tone sequential burst which is predefined.
HOME CHANNEL (HOME)
Press the assigned programmable key to recall the pre-defined Home channel.
HORN ALERT
Press the assigned programmable key to turn the Horn Alert function “ON” or “OFF.”
If you receive a call from the base station with 2-Tone, 5-Tone or DTMF signaling,
horn alert will be activated and your vehicle’s will sound.
PUBLIC ADDRESS
Press the assigned programmable key to use the transceiver as a PA amplifier. When
you enable this function, a tone sounds. The public address can be used even while
scanning and receiving a call.
EXT. ACC1
Press the assigned programmable key to toggle output port “1” “on” and “off.”
EXT. ACC2
Press the assigned programmable key to toggle output port “2” “on” and “off.”
VX-4100 SERIES OPERATING MANUAL
11
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
DIRECT CH#1 TO DIRECT CH#4
Press the assigned programmable key to recall the Dealer pre-programmed channel
directly.
REC/PLAY (VOICE STORAGE: OPTION)
This function, which requires the optional Voice Storage Unit, allows you to record
and play back incoming receiver audio.
Recording:
Press the assigned Rec/Play programmable key for more than 1.5 seconds to toggle
the recording feature “on” and “off.” If the incoming signal is being heard through
the speaker when the recording feature is set to “on,” the received audio will be
recorded. The last 2 minutes of incoming audio will be stored on a first-in, first-out
basis.
Playback:
Press the assigned Rec/Play key momentarily to start playback. During playback,
pressing then [] key lets you jump forward 8 seconds. To stop playback before the
stored message is complete, press the [A] key.
AF MIN VR
Press the assigned programmable key to reduce the audio output to the (lower) level
programmed by your Dealer.
12
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
ADVANCED OPERATION
ARTS (Auto Range Transpond System)
This system is designed to inform you when you and another ARTS-equipped station
are within communication range.
During ARTS operation, your radio automatically transmits for about 1 second every
25 seconds (the interval is programmed by the Dealer) in an attempt to shake hands
with the other station.
If you move out of range for more than two minutes, your radio senses that no signal
has been received, three beeps from the beeper will sound. If you subsequently move
back into range, a single beep will be heard whenever your radio shakes hands with
the other station.
DTMF Paging System
This system allows paging and selective calling, using DTMF tone sequences.
When your radio is paged by a station bearing a tone sequence which matches yours,
your radio’s squelch will open and the alert will sound. The three-digit code of the
station which paged you will be displayed on your radio’s LCD.
VX-4100 SERIES OPERATING MANUAL
13
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
OPTIONAL ACCESSORIES
FVP-25
FVP-35
DVS-5
VTP-50
FP-1023A
MLS-100
LF-1
MH-700D
MH-25A8J
MD-11A8J
VPL-1
Encryption/DTMF Pager Unit
Encryption Unit
Voice Storage Unit
VX-Trunk Unit
External Power Supply
Mobile Loudspeaker (12 W Peak Power)
Line Filter
DTMF Back-lit Microphone
Microphone
Desktop Microphone
Programming Kit
Availability of accessories may vary; some accessories are supplied standard per
local requirements, others may be unavailable in some regions.
Check with your VERTEX STANDARD Dealer for changes to this list.
14
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
NOTES
VX-4100 SERIES OPERATING MANUAL
15
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
NOTES
16
VX-4100 SERIES OPERATING MANUAL
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the user’s authorization to operate this device.
Vertex Standard Co., Ltd.
FCC ID: K6610353030/IC ID: 511B-10353030
Printed in Japan
VERTEX STANDARD CO., LTD.
All rights reserved.
No portion of this manual
may be reproduced
without the permission of
VERTEX STANDARD CO., LTD.
Vertex Standard Co., Ltd.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2003:08:26 02:50:46Z
Modify Date                     : 2004:11:13 05:24:24+09:00
Page Count                      : 20
Creation Date                   : 2003:08:26 02:50:46Z
Mod Date                        : 2004:11:13 05:24:24+09:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : manual
Metadata Date                   : 2004:11:13 05:24:24+09:00
Creator                         : manual
Title                           : ...p65
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K6610353030

Navigation menu