Yaesu Musen 20415X20 AMATEUR RADIO WITH SCANNING RECEIVER User Manual pmd
Yaesu Musen Co., Ltd. AMATEUR RADIO WITH SCANNING RECEIVER pmd
Users Manual
FCC ID: K6620415X20 / IC:511B-20415X20 144/430 MHz DUAL BAND FM TRANSCEIVER WITH GPS VX-8GR OPERATING MANUAL VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU UK LTD. Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. VERTEX STANDARD HK LTD. Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong VERTEX STANDARD (AUSTRALIA) PTY., LTD. Normanby Business Park, Unit 14/45 Normanby Road Notting Hill 3168, Victoria, Australia FCC ID: K6620415X20 / IC:511B-20415X20 FCC ID: K6620415X20 / IC:511B-20415X20 INTRODUCTION The Ultra Compact VX-8GR (2.4”W x 3.7”H x 1.1”D) is equipped with a GPS receiver and thinner than the previous advanced model - It is packed with advanced technology and features, designed for outdoor operation. It is submersible (IPX5) and shockproof! The compact case combines a rugged die-cast chassis with the clean, tough polycarbonate resin front panel. Its shockproof versatility will allow you to operate the radio in the toughest environments. The large High-resolution Dot Matrix LCD display provides clear, easy-to-read indication of both “A” (Main band) and “B” (Sub band) frequencies, the operating mode, and S-meters for both bands. When you engage the Spectrum Scope function, the high-resolution display will indicate relative signal strengths of up to ±50 adjacent channels! The built-in worldwide standard AX.25 Data TNC Modem permits uncomplicated APRS® operation. (Automatic Packet/Position Reporting System: APRS® is a registered trademark of the APRS Software and Bob Bruninga, WB4APR.) The VX-8GR supports APRS® 1200/9600 bps data communication on the “B” (Sub band) band only. You may communicate your location to other APRS® stations along with the position, speed and heading displayed on your radio! You and others will be able to see your APRS® movement on the web! The VX-8GR displays the received station’s positions, heading directions, messages, distances, icons (43 kinds), weather information, object, etc. With the list function you may automatically store and recall up to 20 messages and the APRS® data from up to 40 stations. The built-in GPS Receiver Unit can provide you with your real time APRS® data. An Enhanced Paging and Code Squelch (EPCS) allows you to page a particular station and only receive calls from that station. A security Password may be set, which will allow you to turn on and operate the transceiver only after you enter the Password. A convenient key provides access to Vertex Standard’s WIRES™ (Wide-Coverage Internet Repeater Enhancement System). The Emergency Automatic ID (EAI) function can automatically cause your VX-8GR to transmit your callsign and engage your rig’s microphone, even if you are disabled and unable to press the PTT switch. Additional features include: transmit Time-Out Timer (TOT), Automatic Power-Off (APO), and Automatic Repeater Shift (ARS). Yaesu’s exclusive ARTS™ (Auto-Range Transponder System) which “beeps” the user when you move out of communications range with another ARTS™ equipped station. There is provision to reduce the TX deviation for use in areas of high channel congestion. The squelch circuit allows adjusting the squelch to open at a programmable setting of the S-Meter, thus reducing guesswork in setting the squelch threshold. Provides a DATA jack which enable to displaying the location data (Lat/ Lon) of the after-market GPS receiver, outputs the location data (Lat/Lon) of the built-in GPS receiver unit and the Waypoint data of the received APRS beacon. We appreciate your purchase of the VX-8GR, and encourage you to read this manual thoroughly, and learn about the many exciting features of your thrilling new Yaesu hand-held transceiver! VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CONTROLS & CONNECTIONS ANTENNA Jack Connect the supplied rubber flex antenna (or another antenna presenting a 50-Ohm impedance) here. GPS RECEIVER The internal GPS receiver is located hear. DIAL Knob The main tuning Dial is used to set the operating frequency, and is also used for audio volume level, menu selections, and other adjustments. PTT Switch (“Push To Talk”) Press this switch inward to transmit, and release it (to receive) after your transmission is completed. MIC/SP Jack This four conductor miniature jack connects an optional MH-34 B4B Speaker Microphone, MH37A4B Ear piece/Microphone, or VC-25 VOX Headset. MONI Key Pressing this key disables the noise squelching action, allowing you to hear very weak signals near the background noise level. DATA Jack This two conductor 2.5-mm jack provides connection points for an External computer. VOL Key Rotate the DIAL knob while pressing and holding this key to adjust the audio volume level. EXT DC Jack This coaxial DC jack allows connection to an external DC power source (414V DC). The center pin of this jack is the Positive (+) line. F/W Key Pressing this key activates the “Alternate” key function of the keypad. p(PWR) Switch Press and hold this switch for 2 seconds to toggle the transceiver’s power “on” and “off”. Press this switch briefly while the transceiver is turned “on” to toggle the key lockout feature “on” or “off”. LED Light This white LED will glow (or flash) during “Emergency Channel” operation. It can also be useful as a flash light in a dark environment via the Set Mode Item 45 LED LIGHT. MIC The internal microphone is located hear. KEYPAD The 18 front panel key buttons select many of the most important operating features. The functions of the keys are described in details on pages 4 and 5. TX/BUSY Lamps Thess indicators glow green when a signal is being received and red when transmitting. SPEAKER The internal speaker is located hear. VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 DISPLAY ICONS & INDICATORS “A” Band Display “B” Band Display Icon FREQUENCY CONTROL VOLUME LEVEL TX POWER LEVEL VFO: VFO Mode MR: Memory Mode HI: High Power (5 W) MT: Memory Tune Mode L3: LOW3 Power (2.5 W) HOM: Home Channel Memory L2: LOW2 Power (1 W) PMS: Programmable Memory Scan Mode L1: LOW1 Power (0.02 W) VDW: Dual Watch Active (VFO-Memory Channel) OPERATING FREQUENCY MDW:Dual Watch Active (Memory Channel-Memory Channel) S&PO METER SMS: Smart Search Active Note: When these icon is blinked, the Sub Band Operation feature is active. SQUELCH TYPE & RADIO MODE TN: TSQ: DCS: RTN: PR: PAG: MSG: DC: T-D: D-T: A12: A96: Tone Encoder Active Tone Squelch Active Digital Code Squelch Active Reverse Tone Squelch Active User Programmed Reverse CTCSS Decoder Active Enhanced Paging & Code Squelch (EPCS) Active Message Feature Active Split Tone Feature Active (DCS Encode only) Split Tone Feature Active (Encodes a CTCSS Tone and Decodes a DCS Code) Split Tone Feature Active (Encodes a DCS Code and Decodes a CTCSS Tone) APRS® Feature Active (1200 bps) APRS® Feature Active (9600 bps) MISCELLANEOUS SETTING Repeater Shift Direction (Minus Shift) Repeater Shift Direction (Plus Shift) Independent Transmit Frequencies (Odd Splits) Attenuator Active Bell Alarm Active OPERATING MODE ICON Secondary Keypad Active Internet Connection Feature (WiRESTM) Active DTMF Autodialer Active Emergency Automatic ID (EAI) Feature Active Automatic Power-Off Active Key Lock Active Mute Feature Active Battery Saver Active : Battery Indicator NFM: FM AM: AM Note 1): When the under bar is appended to these icons, the Vibrator function is active. 2): When the dashed under bar is appended to these icons, the CTCSS/DCS/EPCS Vibrator operation is active. VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 KEYPAD FUNCTIONS NOTE Press the a or b key to switch the frequency display between the “Double-size Character” and “Small Character” mode while Mono band operation. PRIMARY FUNCTION (PRESS KEY) Switches the “Upper” frequency to be the “Operating” (TX) Band. Switches the “Lower” frequency to be the “Operating” (TX) Band. SECONDARY FUNCTION (PRESS + No Action No Action THIRD FUNCTION (PRESS AND HOLD KEY) Activates the Dual Receive Feature. Activates the Dual Receive Feature. PRIMARY FUNCTION (PRESS KEY) (1) Moves operation to the next-highest frequency band. (2) Activates the Memory Bank feature. Frequency entry digit “1” Frequency entry digit “2” SECONDARY FUNCTION (PRESS + Moves operation to the next-lowest frequency band Selects the synthesizer steps to be used during VFO operation. Selects the CTCSS Tone, DCS code, EPCS code, or Message. THIRD FUNCTION (PRESS AND HOLD KEY) (1) Select the Bandwidth for the VFO scanner. (2) Select the Memory Scan mode. No Action No Action PRIMARY FUNCTION (PRESS KEY) Reverses transmit and receive frequencies while working through a repeater. Frequency entry digit “4” Frequency entry digit “5” SECONDARY FUNCTION (PRESS + Switches operation to the “Home” (favorite frequency) channel. Activates the ARTS feature. Activates the Memory Scan “Skip” channel selection mode. THIRD FUNCTION (PRESS AND HOLD KEY) Activates the EMERGENCY function. No Action No Action PRIMARY FUNCTION (PRESS KEY) Activates the Internet Connection feature. Frequency entry digit “7” Frequency entry digit “8” SECONDARY FUNCTION (PRESS + Selects the desired transmit power output level. Activates the Audio Mute Feature. Activates the Spectrum Analyzer (Spectra-ScopeTM) feature. THIRD FUNCTION (PRESS AND HOLD KEY) No Action. No Action No Action VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 KEYPAD FUNCTIONS Activate the APRS (Automatic Position Reporting System) function. Toggle the key lock feature “on” and “off” while the transceiver is turned “on”. PRIMARY FUNCTION (PRESS KEY) Activates the transmitter. No Action No Action SECONDARY FUNCTION (PRESS + Activates the transmitter with the “high” power temporarily while the transceiver is “low” power operation. Enter the Set Mode. Toggle the transceiver’s power “on” and “off”. THIRD FUNCTION (PRESS AND HOLD KEY) Activates the Transmitter. Frequency entry digit “3” Selects the receive mode between AM and FM. PRIMARY FUNCTION (PRESS KEY) USA Version: Disables the Noise and Tone Squelch System. EXP Version: Activates the T.CALL (1750 Hz) for repeater access. Selects the DTMF mode. Activates the CTCSS or DCS operation. SECONDARY FUNCTION (PRESS + Adjusts the Squelch threshold level. No Action Engage the Special Search mode. THIRD FUNCTION (PRESS AND HOLD KEY) USA Version: Disables the Noise and Tone Squelch System. EXP Version: Activates the T.CALL (1750 Hz) for repeater access. Frequency entry digit “6” Switches frequency control between the VFO and Memory System. PRIMARY FUNCTION (PRESS KEY) No Action Selects the direction of the uplink frequency shift (either “–”, “+”, or “simplex”) during repeater operation. Activates the “Memory Tune” mode while in the Memory Recall mode. SECONDARY FUNCTION (PRESS + Toggle the DIAL knob function between the “Frequency Control” and “Receiver Audio Control”. No Action Activates the Priority (Dual Watch) function. THIRD FUNCTION (PRESS AND HOLD KEY) Rotate the DIAL knob while holding this key to adjust the audio volume level. Frequency entry digit “9” Frequency entry digit “0” PRIMARY FUNCTION (PRESS KEY) Activates the “Secondary” key function. Enters the “Special Memory” mode. Activates the Sub Band Operation feature. SECONDARY FUNCTION (PRESS + Disables the “Secondary” key function. No Action No Action THIRD FUNCTION (PRESS AND HOLD KEY) Activates the “Memory Write” mode (for memory channel storage). VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ACCESSORIES & OPTIONS ACCESSORIES SUPPLIED WITH THE VX-8DR Antenna Li-Ion Battery Pack Battery Charger Belt Clip Screws Plastic Cap Sheet Operating Manual Warranty Card 1 pc 1 pc 1 pc YHA-72 (Q3000236) FNB-101LI (7.4V/1,100mAh: AAG10X001) NC-86B (for USA version: Q9500149) or NC-86C (for EXP version: Q9500150) 1 pc (RA1053600) 2 pcs (M3x10SUS: U24310020) 1 pc (RA1054200) 1 pcs (RA1231300) 1 pc 1 pc VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ACCESSORIES & OPTIONS AVAILABLE OPTIONS FOR YOUR VX-8DR CSC-101LI FBA-39 FNB-101LI FNB-102LI CD-41 NC-86B/C/U E-DC-5B E-DC-6 CN-3 MH-34B4B MH-37A4B CT-44 CT-144 CT-143 Soft Case 3 x “AA” Cell Battery Case (batteries not supplied) Li-Ion Battery Pack (7.4V/1,100 mAh) Li-Ion Battery Pack (7.4V/1,800 mAh) Rapid Charger (requires NC-86B/C/U) Battery Charger for the CD-41 DC Cable w/Noise Filter DC Cable; plug and wire only BNC-to-SMA Adapter Speaker/Microphone Ear peace Microphone Microphone Adapter Clone Cable PC Connection Cable : “B” suffix is for use with 120 VAC (Type-A plug), “C” suffix is for use with 230 VAC (Type-C plug), and “U” suffix is for use with 230 VAC (Type-BF plug). Availability of accessories may vary. Some accessories are supplied as standard per local requirements, while others may be unavailable in some regions. Consult your Yaesu Dealer for details regarding these and any newly-available options. Connection of any non-Yaesu approved accessory, should it cause damage, may void the Limited Warranty on this apparatus. VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 INSTALLATION OF ACCESSORIES ANTENNA INSTALLATION The supplied antenna provides good results over the entire frequency range of the transceiver. However, for enhanced base station medium-wave and shortwave reception, you may wish to connect an external (outside) antenna. TO INSTALL THE SUPPLIED ANTENNA Hold the bottom end of the antenna, then screw it onto the mating connector on the transceiver until it is snug. Do not over-tighten by use of extreme force. Notes: Never transmit without having an antenna connected. Carefully turn the supplied antenna onto the SMA jack. Never twist the upper part of the antenna while screwing it onto the mating connector of the transceiver. If using an external antenna for transmission, ensure that the SWR presented to the transceiver is 1.5:1 or lower. BELT CLIP INSTALLATION Install the supplied Belt Clip to the FNB-101LI Battery Pack using the supplied two screws (Figure 1). Use only the screws included with the Belt Clip to mount the Belt Clip to the back of the Battery Pack! If you do not need the Belt Clip, install the supplied Plastic Cap to the Battery Pack (Figure 2). If you install the belt clip later, push the Plastic Cap out with a small tool or screwdriver. Figure 1 Figure 2 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 INSTALLATION OF ACCESSORIES INSTALLATION OF FNB-101LI BATTERY PACK The FNB-101LI is a high-performance Lithium-Ion battery providing high capacity in a very compact package. Under normal use, the FNB-101LI may be used for approximately 300 charge cycles, after which operating time may be expected to decrease. An old battery pack, which is displaying diminished capacity should be replaced with a new one. To install the FNB-101LI Battery Pack, carefully mate the battery’s three alignment tabs with their corresponding alignment slots on the transceiver bottom case, then gently press the top side of the Battery Pack until it locks in place with a “click”. To remove the Battery Pack, turn the transceiver off and remove any protective cases. Press the Battery Pack Release Knobs downward to unlock the latch, then remove the Battery Pack from the transceiver. The VX-8GR battery must be correctly installed, to maintain the waterproof integrity. INSTALL BATTERY PACK RELEASE KNOB REMOVE If the battery has never been used, or its charge is depleted, it may be charged by connecting the NC-86B/C Battery Charger, as shown in the illustration, to the EXT DC jack. If only 12 ~ 16 Volt DC power is available, the optional E-DC-5B DC Adapter (with its cigarette lighter plug) or E-DC-6 DC Cable may also be used for charging the battery, as shown in the illustration. CHARGING While the battery is being charged, the display will indicate “CHARGING CHARGING” and the “A” indicator will glow red. The S-meter will deflect according to the charging status. When COMPLETE charging is finished, the display will change to indicate “COMPLETE COMPLETE” and the “A” indicator will glow green. NC-86 VX-8GR OPERATING MANUAL E-DC-5B E-DC-6 FCC ID: K6620415X20 / IC:511B-20415X20 INSTALLATION OF ACCESSORIES BATTERY LIFE INFORMATION When the battery charge is almost depleted, a “Low Voltage” indicator will appear on the display. When this icon appears, it is recommended that you charge the battery soon. BATTERY LIFE (APPROX.) FNB-101LI FNB-102LI FBA-39 144 MHz 5.0 hours 8.5 hours 17 hours 430 MHz 5.0 hours 8.0 hours 16 hours BATTERY INDICATOR : Full battery power : Enough battery power : Low battery power : Poor battery power (w/Blink): Charge (or replace) the battery OPERATING BAND TX 6 seconds, RX 6 seconds, and Squelched 48 seconds (continuous operating cycle). The present battery voltage can be displayed manually on the LCD, by following the instructions on page . Battery capacity may be reduced during extremely cold weather. Keeping the radio inside your parka may help preserve the full charge capacity. 10 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 INSTALLATION OF ACCESSORIES INSTALLATION OF FBA-39 ALKALINE BATTERY CASE (OPTION) The optional FBA-39 Battery Case allows receive monitoring using three “AA” size Alkaline batteries. Alkaline batteries can also be used for low power transmission in an emergency. The power output will only be selectable 1 W/50 mW (for 50/144/430 MHz FM) or 500 mW/50 mW (for 222 MHz FM), or 1 W fixed (for 50 MHz AM). TO INSTALL ALKALINE BATTERIES INTO THE FBA-39 1. Lift up the lower right corner of the rubber cover, and then open the cover (Figure 1). 2. Referring to Figure 2, slide the batteries into the FBA-39 as shown in the illustration, with the Negative [–] side of the batteries touching the spring connections inside the FBA-39. 3. Close the rubber cover. 4. Install the FBA-39 in the transceiver in the same manner as the FNB-101LI. Figure 1 Figure 2 The FBA-39 does not provide connections for charging, since Alkaline cells cannot be re-charged. Therefore, the NC-86B/C, E-DC-5B, or E-DC-6 may safely be connected to the EXT DC jack when the FBA-39 is installed. Notes: The FBA-39 is designed for use only with AA-type Alkaline cells. If you do not use the VX-8DR for a long time, remove the Alkaline batteries from the FBA-39, as battery leakage could cause damage to the FBA-39 and/or the transceiver. VX-8GR OPERATING MANUAL 11 FCC ID: K6620415X20 / IC:511B-20415X20 INTERFACE OF PACKET TNCS The VX-8GR may be used for Packet operation, using the optional CT-44 Microphone Adapter (available from your Yaesu dealer) for easy interconnection to commonly-available connectors wired to your TNC. The audio level from the receiver to the TNC may be adjusted by rotating the DIAL knob while pressing and holding the g key, as with voice operation. The input level to the VX-8GR from the TNC should be adjusted at the TNC side; the optimum input voltage is approximately 5 mV at 2000 Ohms. Be sure to turn the transceiver and TNC off before connecting the cables, to prevent voltage spikes from damaging your transceiver. CT-44 Microphone Adapter TNC EAR SP GND 10 µF MIC 12 2 k MIC PTT GND VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION Hi! I’m R. F. Radio, and I’ll be helping you along as you learn the many features of the VX-8GR. I know you’re anxious to get on the air, but I encourage you to read the “Operation” section of this manual as thoroughly as possible, so you’ll get the most out of this fantastic new transceiver. Now. . .let’s get operating! SWITCHING POWER ON AND OFF 1. Be sure the battery pack is installed, and that it is fully charged. Connect the antenna to the top panel ANTENNA jack. 2. Press and hold in the p(PWR) switch (on the left side of the front panel) for 2 seconds. Two beeps will be heard when the switch has been held long enough. The opening message will appear briefly on the display, then the frequency display will appear. After another two seconds, the receive-mode Battery Saver function will become active, unless you have disabled it (see page xx). 3. To turn the VX-8GR off, press and hold in the p(PWR) switch again for 2 seconds. If you don’t hear the two “Beep” tones when the radio comes on, the Beeper may have been disabled via the Menu system. See page 27, which tells you how to reactivate the Beeper. ADJUSTING THE VOLUME LEVEL Rotate the DIAL knob while pressing and holding the g key to set the desired audio level. Clockwise rotation increases the volume level. 1) The Volume level may be set on the “A-Band” and “B-Band” separately. 2) You may set the Audio Output Level to the Speaker, and the Earphone Output Level individually. The “SP VOLUME” notation appears in the S- & PO meter area while adjusting the Speaker Output Level. The “HP VOLUME” notation appears in the S- & PO meter area while adjusting the Earphone Output Level. 3) Pressing the f key followed by the g key, the DIAL knob function changes to the Volume Level adjustment instead of the frequency control. In this case, the “Volume Level Indicator” on the display blinks. Pressing the f key followed by the g key again, returns the DIAL knob function to the frequency control. You may also change the g key function via Set Mode Item 99: VOLUME MODE. See page xx for details. VX-8GR OPERATING MANUAL 13 FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION SQUELCH ADJUSTMENT The VX-8GR’s Squelch system allows you to mute the background noise when no signal is being received. Not only does the Squelch system make “standby” operation more pleasant, it also significantly reduces battery current consumption. The Squelch system may be adjusted independently for the FM and Wide-FM (FM Broadcast) modes. 1. Press the f key, then press the e key on the left side of the radio. This provides a “Short-cut” to Set Mode Item 85: SQL LEVEL LEVEL. 2. Now, rotate the DIAL knob to the point where the background noise is just silenced (typically at a setting of about “3” or “4” on the scale); this is the point of maximum sensitivity to weak signals. 3. When you are satisfied with the Squelch threshold setting, press the PTT key briefly to save the new setting and exit to normal operation. 4. You may also adjust the Squelch setting by using the “Set” (Menu) mode. See page xx for details. 1) The Squelch level may be set on the “Main” and “Sub” bands separately. 2) If you’re operating in an area of high RF pollution, you may need to consider “Tone Squelch” operation using the built-in CTCSS Decoder. This feature will keep your radio quiet until a call is received from a station sending a carrier which contains a matching (sub audible) CTCSS tone. Or if your friends have radios equipped with DCS (Digital Coded Squelch) like your VX-8GR, try using that mode for silent monitoring of busy channels. 24-HOUR CLOCK The VX-8GR has a 24-hour clock with a calendar which covers all dates from January 1, 2000 through December 31, 2099. Set the clock according to the “Clock Set” column on page xx 14 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION SELECTING THE OPERATING BAND In the factory default configuration, the VX-8GR operates in the “Dual Receive” mode. During Dual Receive operation, the “A-Band” frequency will be displayed on the upper part of the LCD, and the “B-Band” frequency will be displayed on the lower part. The “Operating” band (the band on which transmission and band/frequency changes are possible) is shown in large characters, and “Receive only” band is shown in small characters. Press the a key briefly to engage the “A-Band” frequency as the “Operating” band. Alternatively, press the b key briefly to engage the “B-Band” frequency, as described previously. Press and hold in the a or b key for 1/2 seconds to switch to Mono Band Operation. During Mono band operation, you may change the display between “double-size character” and “large character” by pressing the a/b key. VX-8GR OPERATING MANUAL 15 FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION SELECTING THE FREQUENCY BAND The VX-8GR covers an incredOPERATING BAND FREQUENCY RANGE [BAND NUMBER] “VFO-A” “VFO-B” ibly wide frequency range, over AIR Band [1] 108-137 MHz 108-137 MHz which a number of different opVHF HAM Band [2] 137-174 MHz 137-174 MHz erating modes are used. ThereVHF Band [3] 174-222 MHz 174-222 MHz INFO 1 Band [4] 222-420 MHz 222-420 MHz fore, the VX-8GR’s frequency [5] UHF HAM Band 420-470 MHz 420-470 MHz coverage has been divided into UHF Band [6] 470-800 MHz 470-580 MHz different operating bands. Each INFO 2 Band [7] 800-999.99 MHz – band has its own preset channel USA Version: Cellular Blocked steps and operating modes. You can change the channel steps and operating modes later, if you like (see page xx). TO CHANGE OPERATING BANDS 1. Press the B key repeatedly. You will see the LCD indication change to a higher frequency band each time you press the B key. A Band Number according to the receiving frequency is also displayed. 2. If you wish to move the operating band selection downward (toward lower frequencies), press the f key first, then press the B key. 3. The VX-8DR uses a dual VFO system (described previously). To switch TX/RX operation from the “VFO-A” to the “VFO-B” instantly, press the b key briefly. Pressing the a key will return TX/RX operation to “VFO-A”. The frequency band shown in “Large” characters is the band on which transmission is possible; the band shown in “Small” characters may only be used for reception. 4. Once you have selected the desired band, you may initiate manual tuning (or scanning). See the discussions on the next page. If desired, you may omit (skip) one or more bands from the band selection loop for faster recall of your favorite operating bands. See page xx for details. 16 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION FREQUENCY NAVIGATION The VX-8GR will initially be operating in the “VFO” mode, as just described. This is a frequency step system which allows free tuning throughout the currently-selected operating band. Three basic frequency navigation methods are available on the VX-8GR: 1) TUNING DIAL Rotation of the DIAL knob allows tuning in the pre-programmed steps established for the current operating band. Clockwise rotation of the DIAL knob causes the VX-8GR to be tuned toward a higher frequency, while counter-clockwise rotation will lower the operating frequency. If you press the f key briefly, then rotate the DIAL knob, frequency steps of 1 MHz will be selected. This feature is extremely useful for making rapid frequency excursions over the wide tuning range of the VX-8GR. 2) DIRECT KEYPAD FREQUENCY ENTRY The desired operating frequency may be entered directly from the keypad. The operating mode will automatically be set once the new frequency is entered via the keypad. To enter a frequency from the keypad, just press the numbered digits on the keypad in the proper sequence. There is no “Decimal point” key on the VX-8GR. However, there is a shortcut for frequencies ending in zero - press the c key after the last non-zero digit. Examples: To enter 146.520 MHz, press 146520 To enter 430.000MHz, press 43c Sub Band Operation key followed by the key, you can cause the controls When press the (except the TX function) to act on the “Sub” band. When the Sub Band operation is activated, the Main band’s “Frequency Control” icon will blinks. After making conkey followed by the trol to the Sub band, press the key to return control to the “Main” band. VX-8GR OPERATING MANUAL 17 FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION FREQUENCY NAVIGATION 3) SCANNING From the VFO mode, press and hold in the B key for one second, and while still holding in the B key, rotate the DIAL knob to select the bandwidth for the VFO scanner. Release the B key to begin scanning toward a higher frequency. The scanner will stop when it receives a signal strong enough to break through the Squelch threshold. The VX-8GR will then hold RESUME on that frequency according to the setting of the “RESUME RESUME” mode (Menu Item 77: SCAN RESUME RESUME). If you wish to reverse the direction of the scan (i.e. toward a lower frequency, instead of a higher frequency), just rotate the DIAL knob one click in the counter-clockwise direction while the VX-8GR is scanning. The scanning direction will be reversed. To revert to scanning toward a higher frequency once more, rotate the DIAL knob one click clockwise. Press the PTT switch briefly to cancel the scanning. See page xx for more details regarding Scan Operation. Dual Receive Notice The VX-8GR may receive very strong signals on the Image frequency, and/or the receiver sensitivity may be somewhat reduced by the combination of the “A-Band” and “B-Band” frequencies while Dual Receive operation is engaged. If you experience interference that you suspect may be coming in via an “Image” path, you may calculate the possible frequencies using the formulas below. This information may be used in the design of effective countermeasures such as traps, etc. 9.8304 MHz x n 4.9152 MHz x n 11.7 MHz x n 6.1440 MHz x n (n is an integer: 1, 2, 3, …) “A-Band” Freq. = (“B-Band” Freq. ± 46.35 MHz) x n “B-Band” Freq. = (“A-Band” Freq. ± 47.25 MHz) x n (@ “A-Band” = NFM) “B-Band” Freq. = (“A-Band” Freq. ± 45.8 MHz) x n (@ “A-Band” = WFM) 18 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION TRANSMISSION Once you have set up an appropriate frequency inside one of the dual amateur bands on which the VX-8GR can transmit (144 MHz or 430 MHz), you’re ready to transmit. These are the most basic steps; more advanced aspects of transmitter operation will be discussed later. 1. To transmit, press the PTT switch, and speak into the front panel microphone (located in the upper right-hand corner of the speaker grille) in a normal voice level. The LED of the “A” or “B” which is designated the “Main” band will glow red during transmission. 2. To return to the receive mode, release the PTT switch. 3. During transmission, the relative power level will be indicated on the LCD. Additionally, the “L1”, “L2”, “L3”, or “HI” icon will appear at the left side of the PO meter, corresponding with the “Power” Level setting. 1) If you’re just talking to friends in the immediate area, you’ll get much longer battery life by switching to Low Power operation. To do this, press the f key, then press the d key so that the “Low Power” icon appears at the bottom of the display. And don’t forget: always have an antenna connected when you transmit. 2) Transmission is not possible on “Sub” band and any operating bands other than the 144 MHz and 430 MHz bands on the “Main” band. 3) Never transmit without having an antenna connected. CHANGING THE TRANSMITTER POWER LEVEL You can select between a total of four transmitter power levels on your VX-8GR. The exact power output will vary somewhat, depending on the voltage supplied to the transceiver. With the standard FNB-101LI Battery Pack and external DC source, the power output levels available are: “L1”, “L2”, “L3”, or “HI” To change the power level: 1. The default setting for the power output is “High;” in this configuration, the display shows the “HI” icon. Pressing the f key, followed by the d key, causes the power level “L1”, “L2”, or “L3” to appear. 2. Press the f key, followed by the d key (repeatedly, if necessary) to make the “HI” icon appear and restore “High Power” operation. VX-8GR OPERATING MANUAL 19 FCC ID: K6620415X20 / IC:511B-20415X20 OPERATION TRANSMISSION 1) The VX-8GR is smart! You can set up Low power on one band (like UHF), while leaving VHF on High power, and the radio will remember the different settings on each band. And when TRANSMIT POWER FNB-101LI/-102LI FBA-39 you store memories, you can store High and (w/Fresh Batteries) or EXT DC (7.4 V) Low power settings separately in each HI: 5.0 W, memory, so you don’t waste battery power L3: 2.5 W, L2: 1.0 W, when using very close-in repeaters! L2: 1.0 W, L1: 0.05 W L1: 0.05 W 2) When you are operating on one of the Low key, then press the PTT switch, to cause the VXpower settings, you can press the 8GR to transmit (temporarily) on High power. After one transmission, the power level will revert to the previously-selected Low power setting. 20 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ADVANCED OPERATION Now that you mastered the basics of VX-8GR operation, let’s learn more about some of the really neat features. KEYBOARD LOCKING In order to prevent accidental frequency change or inadvertent transmission, various keys and switches may be locked out. The possible lockout combinations are: KEY KEY: DIAL: DIAL KEY&DIAL KEY&DIAL: PTT PTT: KEY&PTT KEY&PTT: DIAL&PTT DIAL&PTT: ALL ALL: Just the front panel keys are locked out Just the top panel DIAL is locked out Both the DIAL knob and Keys are locked out The PTT switch is locked (TX not possible) Both the keys and PTT switch are locked out Both the DIAL knob and PTT switch are locked out All of the above are locked out To lock out some or all of the keys: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 46: LOCK LOCK. 3. Press the m key briefly to enable selection of this Menu Item. 4. Rotate the DIAL knob to choose between one of the locking schemes as outlined above. 5. When you have made your selection, press the PTT switch to save the new setting and resume normal operation. To activate the locking feature: Press the p(PWR) switch briefly. The “k” icon will appear on the LCD. To cancel locking, press the p(PWR) switch again. Even when “ALL” keys have been locked out, one key actually is not locked out: the p(PWR) switch remains available so you can unlock your keypad when you want to! VX-8GR OPERATING MANUAL 21 FCC ID: K6620415X20 / IC:511B-20415X20 ADVANCED OPERATION ADJUSTING THE KEYPAD BEEPER VOLUME LEVEL A keypad beeper provides useful audible feed back whenever a key button is pressed. The keypad beeper level changes according to the receiver audio volume level setting. However, you may adjust the volume balance between the receiving audio and keypad beeper using Set Mode Item 11: BEEP LEVEL LEVEL. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 9: BEEP LEVEL LEVEL. 3. Press the m key briefly to enable selection of this Set Mode Item. 4. Rotate the DIAL knob to select the desired level. 5. When you have made your choice, press the PTT switch to save the new setting and return to normal operation. Additionally, if you want to turn the beep off: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 11: BEEP SELECT SELECT. 3. Press the m key briefly to enable selection of this Set Mode Item. OFF 4. Rotate the DIAL knob to change the setting to “OFF OFF”. 5. When you have made your choice, press the PTT switch to save the new setting and return to normal operation. 6. If you wish to re-enable the Beeper, just repeat the above KEY KEY & SCAN procedure, rotating the DIAL knob to select “KEY KEY” or “KEY SCAN” in step “4” above. KEY KEY: The beeper sounds when you press any key. KEY & SCAN SCAN: The beeper sounds when you press a key or when the scanner stops. SETTING THE FREQUENCY DISPLAY IMAGE SIZE When operating in “Mono” band, pressing the a or b key, causes the LCD to “toggle” between display of double-size characters and large characters. However, this feature does not work during Dual Receive operation, as two frequencies are displayed in that instance. DOUBLE-SIZE CHARACTERS 22 LARGE CHARACTERS VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ADVANCED OPERATION AUDIO MUTING The Audio Mute feature is useful in situations where it would be helpful to reduce the audio level of the “Receive Only” band (Small character display) whenever you receive a signal on the “Main” band (Large character display) during Dual Receive operation. To activate the Audio Mute feature: 1. Press the f key, then press the 7 key. This provides a “Short-cut” to Set Mode Item 57: MUTE MUTE. 2. Rotate the DIAL knob to select the desired muting level MUTE 30% (MUTE 30%, MUTE 50% 50%, MUTE 100% 100%, or OFF OFF). 3. When you have made your choice, press the PTT switch to save the new setting and return to normal operation. When the Audio Mute feature is activated, the “ ” icon will appear on the display, and the “ ” icon blinks while muting the “Receive Only” band audio. To cancel the Audio Mute feature, just repeat the above proceOFF dures, selecting “OFF OFF” in step 2 above. KEYPAD/LCD ILLUMINATION Your VX-8GR includes a reddish illumination lamp which aids in nighttime operation. The red illumination yields clear viewing of the display in a dark environment, with minimal degradation of your night vision. Three options for activating the lamp are provided: KEY 2sec - KEY 10sec 10sec: Illuminates the Keypad/LCD for the selected illumination time when any key is pressed. CONTINUOUS CONTINUOUS: Illuminates the Keypad/LCD continuously. OFF OFF: Disables the Keypad/LCD lamp. Here is the procedure for setting up the Lamp mode: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 41: LAMP LAMP. 3. Press the m key briefly to enable selection of this Set Mode Item. 4. Rotate the DIAL knob to select one of the three modes described above. 5. When you have made your choice, press the PTT switch to save the new setting and return to normal operation. VX-8GR OPERATING MANUAL 23 FCC ID: K6620415X20 / IC:511B-20415X20 ADVANCED OPERATION CHANGING THE CHANNEL STEPS The VX-8GR’s frequency synthesizer provides the option of utilizing tuning steps of 5, 6.25, 8.33, 10, 12.5, 15, 20, 25, 50 and 100 kHz per step. The VX-8GR is set up at the factory with different default steps for each operating band which are probably satisfactory for most operation. However, if you need to change the channel step increments, the procedure to do so is very easy. 1. Press the f key, then press the 1 key on the left side of the radio. This provides a “Short-cut” to Set Mode Item 89: STEP FREQUENCY FREQUENCY. 2. Rotate the DIAL knob to select the desired step size. 3. Press the PTT switch to save the new setting and return to normal operation. 1) 8.33 kHz steps are available only when receiving on the Air band. 2) 5 kHz steps are not available for use on 250 - 300 MHz, nor above 580 MHz. CHANGING THE RECEIVING MODE The VX-8GR provides for automatic mode changing when the radio is tuned to different operating frequencies. However, should an unusual receiving situation arise in which you need to change to a differkey. The receiving ent receiving mode, just press the modes available are: AUTO AUTO: The receive mode is automatically set according to the default values for the selected frequency range NFM NFM: Frequency Modulation AM AM: Amplitude Modulation Unless you have a compelling reason to do so, leave the Automatic Mode Selection feature on in order to save time and trouble when changing bands. If you make a mode change for a particular frequency or station, you can always store that one channel into memory, as the mode setting will be memorized along with the frequency information. 24 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ADVANCED OPERATION SQL S-METER A special SQL (Squelch) S-meter feature is provided on this radio. This feature allows you to set the squelch so only signals exceeding a certain S-meter level will open the squelch. To set up the S-meter squelch feature for operation, use the following procedure: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 86: SQL SMETER METER. 3. Press the m key briefly to enable selection of this Set Mode Item. 4. Rotate the DIAL knob to select the desired signal strength LEVEL1 - LEVEL9 or OFF level for the squelch threshold (LEVEL1 OFF). 5. When you have made your choice, press the PTT switch to save the new setting and return to normal operation. 1) When the SQL S-meter is activated, the S-meter segment corresponding to the squelch threshold which was set by step 4 above will blink. 2) The receiver’s squelch will open based on the higher of the levels set by the Noise Squelch or the S-meter Squelch system. For example: a) If the Noise Squelch (SQL control) is set so that signals at a level of “S-3” will open the squelch, but the SQL S-meter (Set Mode Item 93) is set to “LEVEL 5,” the squelch will only open on signals which are “S5” or stronger on the S-meter. b) If the SQL S-meter is set to “S3,” but the Noise Squelch is set to a high level which will only pass signals which are Full Scale on the S-meter, the squelch will only open on signals which are Full Scale on the S-meter. In this case, the Noise Squelch overrides the action of the S-meter Squelch. VX-8GR OPERATING MANUAL 25 FCC ID: K6620415X20 / IC:511B-20415X20 REPEATER OPERATION GENERAL Repeater stations, usually located on mountaintops or other high locations, provide a dramatic extension of the communication range for low-powered hand-held or mobile transceivers. The VX-8GR includes a number of features, which make repeater operation simple and enjoyable. REPEATER SHIFTS Your VX-8DR has been configured, at the factory, for the repeater shifts customary in your country. For the 144 MHz band, this usually will be 600 kHz, while the 430 MHz shift will be 1.6 MHz, 7.6 MHz, or 5 MHz (USA version). Depending on the part of the band in which you are operating, the repeater shift may be either downward ( ) or upward ( ), and one of these icons will appear at the bottom of the LCD when repeater shifts have been enabled. AUTOMATIC REPEATER SHIFT (ARS) The VX-8GR provides a convenient Automatic Repeater Shift feature, which causes the appropriate repeater shift to be automatically applied whenever you tune into the designated repeater sub-bands in your country. These sub-bands are shown below. If the ARS feature does not appear to be working, you may have accidentally disabled it. To re-enable ARS: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 69 69:: RPT ARS ARS. 3. Press the m key briefly to enable selection of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON”(to enable Automatic Repeater Shift). 5. When you have made your choice, press the PTT switch to save the new setting and return to normal operation. ARS-Repeater Subbands 2-m Version A 145.1 145.5 146.0 146.4 147.0 146.6 147.6 148.0 147.4 145.6 145.8 European Version 70-cm Version A 440.0 438.20 433.00 433.40 434.60 435.00 26 445.0 439.45 450.0 Euro Version 1 Euro Version 2 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 REPEATER OPERATION MANUAL REPEATER SHIFT ACTIVATION If the ARS feature has been disabled, or if you need to set a repeater shift direction other than that established by the ARS, you may set the direction of the repeater shift manually. To do this: 1. Press the f key, then press the 6 key. This provides a “Short-cut” to Set Mode Item 70: RPT SHIFT SHIFT. 2. Rotate the DIAL knob to select the desired shift among –RPT +RPT SIMPLEX “–RPT –RPT,” “+RPT +RPT,” and “SIMPLEX SIMPLEX.” 3. Press the PTT switch to save the new setting and exit to normal operation. CHANGING THE DEFAULT REPEATER SHIFTS If you travel to a different region, you may need to change the default repeater shift, to ensure compatibility with local operating requirements. To do this, follow the procedure below: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 71: RPT SHIFT FREQ FREQ. 3. Press the m key briefly to enable selection of this Set Mode Item. 4. Rotate the DIAL knob to select the new repeater shift magnitude. 5. Press the PTT switch to save the new setting and return to normal operation. If you just have one “odd” split that you need to program, don’t change the default repeater shift! Enter the transmit and receive frequencies separately, as shown on page ??. VX-8GR OPERATING MANUAL 27 FCC ID: K6620415X20 / IC:511B-20415X20 REPEATER OPERATION CHECKING THE REPEATER UPLINK (INPUT) FREQUENCY It often is helpful to be able to check the uplink (input) frequency of a repeater, to see if the calling station is within direct (“Simplex”) range. To do this, just press the h key. You’ll notice that the display has shifted to the repeater uplink frequency. Press the h key again to cause operation to return to normal monitoring of the repeater downlink (output) frequency. While you are listening on the input frequency of the repeater using the h key, the repeater offset icon (“ ” or ”) will blink. The configuration of h key may be set either to “RV” (for checking the input frequency of a repeater, or “HM” (for instant switching to the “Home” channel for the band you are operating on). To change the configuration of h key, use Set Mode Item 34: HOME/REVERSE. See page xx. 28 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION CTCSS OPERATION Many repeater systems require that a very-low-frequency audio tone be superimposed on your FM carrier in order to activate the repeater. This helps prevent false activation of the repeater by radar or spurious signals from other transmitters. This tone system, called “CTCSS” (Continuous Tone Coded Squelch System), is included in your VX-8GR, and is very easy to activate. CTCSS setup involves two actions: setting the Tone Frequency and then setting the Tone Mode. These functions are set up using Set Mode Items 88: SQL TYP and 91: TONE FREQUENCY. 1. Press the f key, then press the M key. This provides a “Short-cut” to Set Mode Item 88: SQL TYPE TYPE. TONE 2. Rotate the DIAL knob so that “TONE TONE” appears on the display. This activates the CTCSS Encoder. 3. Rotation of the DIAL knob one more “click” in step “2” TSQ TSQ above will also activate the “TSQ TSQ” decode function. When “TSQ TSQ” is displayed, the Tone Squelch system is active, which mutes your VX-8GR’s receiver until it receives a call from another radio sending out a matching CTCSS tone. This can helpful in a high RF congested location by keeping your radio quiet until a call is received from a specific station with a matching CTCSS tone. DCS You may notice an additional “DCS DCS” indication appearing while you rotate the DIAL knob in step 3 above. We’ll discuss the Digital Code Squelch system shortly. REV TONE You may notice “REV TONE” indication on the display while you rotate the DIAL knob in step 3 above. When the Reverse Tone Squelch system is active, the VX-8GR’s receiver is muted when it receives a call from a radio RTN sending a matching CTCSS tone. The “RTN RTN” icon will appear on the display when the Reverse Tone Squelch system is activated. PR FREQ You may notice “PR FREQ” indication on the display while you rotate the DIAL knob in step 3 above, this means the user programmed Reverse CTCSS Decoder will mute your VX-8GR’s receiver when it receives a call from a radio sending a CTCSS tone matching your programmed tone (determine by PR Set Mode Item 65: PR FREQUENCY FREQUENCY). The “PR PR” icon will appear on the display when the Reverse CTCSS Decoder is activated. PAGER MESSAGE You may notice “PAGER PAGER” and “MESSAGE MESSAGE” indication on the display while you rotate the DIAL knob in step 3 above. These appear when the “Enhanced Paging & Code Squelch” and the “Message Feature” are activated. We’ll discuss these functions later. VX-8GR OPERATING MANUAL 29 FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION CTCSS OPERATION 4. When you have made your selection of the CTCSS tone mode, press the M key to save the new setting and exit to normal operation. 5. Press the f key, then press the 2 key. This provides a “Short-cut” to Set Mode Item 91: TONE FREQUENCY FREQUENCY. 6. Rotate the DIAL knob until the display indicates the frequency of the CTCSS tone that you need to send on your transmission (ask the repeater owner/operator if you don’t know the tone frequency). 7. When you have made your selection, press the 2 key briefly to save the new setting and exit to normal operation. This is different from the usual method of restoring normal operation, and it applies only to the configuration of the CTCSS/DCS frequencies. 1) The repeater may or may not CTCSS TONE FREQUENCY (Hz) re-transmit a CTCSS tone - some 67.0 69.3 71.9 74.4 77.0 79.7 systems just use CTCSS to control 82.5 85.4 88.5 91.5 94.8 97.4 access to the repeater, but do not pass it along 100.0 103.5 107.2 110.9 114.8 118.8 when transmitting. If the S-Meter deflects, 123.0 127.3 131.8 136.5 141.3 146.2 but you cannot hear the audio, repeat steps 151.4 156.7 159.8 162.2 165.5 167.9 171.3 173.8 177.3 179.9 183.5 186.2 “1” through “4” above, but rotate the DIAL 189.9 192.8 196.6 199.5 203.5 206.5 so that “TSQ” disappears - this will allow 210.7 218.1 225.7 229.1 233.6 241.8 you to hear all traffic on the channel being 250.3 254.1 – – – – received. 2) During CTCSS operation, you may set up the VX-8GR so a ringing “bell” sound alerts you to an incoming call. See page xx for details. 30 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION DCS OPERATION Another form of tone access control is Digital Code Squelch, or DCS. It is a newer, more advanced tone system which generally provides more immunity from false paging than does CTCSS. The DCS Encoder/Decoder is built into your VX-8GR, and operation is very similar to that just described for CTCSS. Your repeater system may be configured for DCS. The DCS Squelch may be quite useful in Simplex operation if your friends use transceivers equipped with this advanced feature. Note: Just as in CTCSS operation, DCS requires that you set the Tone Mode to DCS and that you select a DCS code. 1. Press the f key, then press the M key. This provides a “Short-cut” to Set Mode Item 88: SQL TYPE TYPE. DCS 2. Rotate the DIAL knob until “DCS DCS” appears on the display; this activates the DCS Encoder/Decoder. 3. Press the M key to save the new setting and exit to normal operation. 4. Press the f key, then press the 2 key. This provides a “Short-cut” to Set Mode Item 21: DCS CODE CODE. 5. Rotate the DIAL knob to select the desired DCS Code (a three-digit number). Ask the repeater owner/operator if you don’t know DCS Code; if you are working simplex, just set up the DCS Code to be the same as that used by your friends. 6. When you have made your selection, press the 2 key to save the new settings and exit to normal operation. Remember that the DCS is an Encode/Decode system, so your receiver will remain muted until a matching DCS code is received on an incoming transmission. Switch the DCS off when you’re just tuning around the band! DCS CODE 023 025 026 031 032 036 043 047 051 053 054 065 071 072 073 074 114 115 116 122 125 131 132 134 143 145 152 155 156 162 165 172 174 205 212 223 225 226 243 244 245 246 251 252 255 261 263 265 266 271 274 306 311 315 325 331 332 343 346 351 356 364 365 371 411 412 413 423 431 432 445 446 452 454 455 462 464 465 466 503 506 516 523 526 532 546 565 606 612 624 627 631 632 654 662 664 703 712 723 731 732 734 743 754 VX-8GR OPERATING MANUAL – – – – – – 31 FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION DCS OPERATION DCS CODE INVERSION The DCS system was first introduced in the commercial LMR (Land Mobile Radio) service, where it is now in widespread use. DCS is sometime referred to by its different proprietary names, such as DPL® (Digital Private Line®, a registered trademark of Motorola, Inc.). DCS uses a codeword consisting of a 23-bit frame, transmitted (sub audible) at a data rate of 134.4 bps (bit/sec). Occasionally, signal inversion can result in the complement of a code being sent or received. This prevents the receiver’s squelch from opening with DCS enabled, as the decoded bit sequence would not match that selected for operation. Typical situations that might cause inversion to occur are: Connection of an external receiver preamplifier. Operating through a repeater. Connection of an external linear amplifier. Note that code inversion does not mean that any of the above listed equipment is defective! In certain amplifier configurations, the output signal (phase) is inverted from the input. Small signal or power amplifiers having an odd number (1, 3, 5, etc.) of amplification stages may result in inversion of a transmitted or received DCS code. While under most circumstances this should not occur (amplifier designs and industry standards take this into account), if you find that your receiver squelch does not open when both you and the other station are using a common DCS code, you or the other station (but not both) can try the following: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 22: DCS INVERSION INVERSION. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select one of the following modes: RX-NORMAL, TX-NORMAL TX-NORMAL: Receive and transmit the Normal DCS Tone. RX-INVERT, TX-NORMAL TX-NORMAL: Receive the Inverted DCS Tone and transmit the Normal DCS Tone. RX-BOTH, TX-NORMAL TX-NORMAL: Receive both Normal and Inverted DCS Tones and transmit the Normal DCS Tone. RX-NORMAL, TX-INVERT TX-INVERT: Receive the Normal DCS Tone and transmit the Inverted DCS Tone. 32 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION DCS OPERATION RX-INVERT, TX-INVERT TX-INVERT: Receive and transmit the Inverted DCS Tone. RX-BOTH, TX-INVERT TX-INVERT: Receive both Normal and Inverted DCS Tones and transmit the Inverted DCS Tone. 5. When you have made your selection, press the PTT switch, to save the new settings and exit to normal operation. This is different from the usual method of restoring normal operation, and it applies only to the configuration of the CTCSS/DCS frequencies. Remember to restore the default RX-NORMAL, TX-NORMAL setting “RX-NORMAL, TX-NORMAL” (Receive and transmit the Normal DCS Tone) when done. VX-8GR OPERATING MANUAL 33 FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION TONE SEARCH SCANNING In operating situations where you don’t know the CTCSS or DCS tone being used by another station, you can command the radio to listen to the incoming signal and scan in search of the tone being used. Two things must be remembered in this regard: You must be sure that your repeater uses the same tone type (CTCSS vs. DCS). Some repeaters do not pass the CTCSS tone; you may have to listen to the station transmitting on the repeater uplink (input) frequency in order to allow Tone Search Scanning to work. To scan for the tone in use: 1. Set the radio up for either CTCSS or DCS Decoder operation (see the previous discussion). In the case of CTCSS, TSQ “TSQ TSQ” will appear on the display; DCS in the case of DCS, “DCS DCS” will appear on the display. 2. Press the f key, then press the 2 key to recall the Set Mode Item 91: TONE FREQUENCY when CTCSS is selected, or Menu Item 21: DCS CODE during DCS operation. TONE SEARCH 3. Press and hold in the B key, the “TONE SEARCH” notation will appear, release the B key to start scanning for the incoming CTCSS or DCS tone/code. 4. When the radio detects the correct tone or code, it will halt on that tone/code, and audio will be allowed to pass. Press the B key to lock in that tone/code, then press the 2 key to exit to normal operation. If the Tone Scan feature does not detect a tone or code, it will continue to scan indefinitely. When this happens, it may be that the other station is not sending any tone. You can press the PTT switch to halt the scan at any time. You can also press the e key during Tone Scanning to listen to the (muted) signal from the other station. When you release the e key, Tone Scanning will resume after about a second. Tone Scanning works either in the VFO or Memory modes. 34 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION EPCS (ENHANCED PAGING & CODE SQUELCH) The VX-8GR includes an Enhanced CTCSS tone encoder/decoder and a dedicated microprocessor providing paging and selective calling features. This allows you to place a call to a specific station (Paging), and to receive calls of your choice directed only to you (Code Squelch). The paging and code squelch systems use two pairs of (alternately switched) CTCSS tones which are stored in the pager memories. Basically, your receiver remains silent until it receives the CTCSS tone pair that matches those stored in the Receiving Pager Memory. The squelch then opens so the caller is heard, and the paging ringer immediately sounds, if activated. When you close the PTT switch to transmit, the CTCSS tone pair that is stored in the Transmitting Pager Memory will be transmitted automatically. On the paged radio, the Code Squelch will close automatically after the incoming page ends. Meanwhile, on the paging radio, the Enhanced Paging and Code Squelch system will be disabled after the PTT switch is released after the paging transmission. You may re-activate the Enhanced Paging and Code Squelch system again. STORING THE CTCSS TONE PAIRS FOR EPCS OPERATION 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 62: PAGER CODE-RX for the Receiving CTCSS Tone Pair or Set Mode Item 63: PAGER CODE-TX for the Transmitting CTCSS Tone Pair. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to set the CTCSS Tone number which corresponds to the first tone of the CTCSS Tone Pair. 5. Press the M key (“ ” icon moves to the right), then rotate the DIAL knob to set the CTCSS Tone number, which corresponds to the second tone of the CTCSS Tone Pair. 6. Press the PTT switch to save the new setting and exit to normal operation. The VX-8GR does not recognize the order of the 1st tone and the 2nd tone. In other words, for example, the VX-8GR considers both CTCSS pairs “10, 35” and “35, 10” to be identical. VX-8GR OPERATING MANUAL 35 FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION EPCS (ENHANCED PAGING & CODE SQUELCH) ACTIVATING THE ENHANCED PAGING & CODE SQUELCH SYSTEM 1. Press the f key, then press the M key. This provides a “Short-cut” to Set Mode Item 88: SQL TYPE TYPE. PAGER 2. Rotate the DIAL knob until “PAGER PAGER” appears on the display; this activates the Enhanced Paging & Code Squelch. 3. Press the PTT switch to save the new setting and activate the Enhanced Paging & Code Squelch. To disable the Enhanced Paging & Code Squelch, just repeat the above procedure, rotate OFF the DIAL knob to select “OFF OFF” in step 2 above. When the Enhanced Paging & Code Squelch feature is actiPAG vated, the “PAG PAG” notation will appear on the display. During Enhanced Paging & Code Squelch operation, you may set up the VX-8GR so that a ringing “bell” sound alerts you when a call is coming in. See next page for details. PAGING ANSWER BACK When you press the PTT switch to respond to a page call, the VX-8GR transmits the same CTCSS tone pair. This tone pair will open the Code Squelch of the calling station. If you prefer, you can have the VX-8GR respond to page calls automatically (“transpond”). To enable this feature: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 61: PAGER ANS-BACK ANS-BACK. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON”. 5. Press the PTT switch to save the new setting and exit to normal operation. The Paging Answer Back feature constitutes a form of “remote control” operation that may be restricted to certain frequencies. U.S. users should confirm the current status of §97.201(b) of the FCC’s rules governing the Amateur service before utilizing this feature on the 144 MHz band. 36 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION CTCSS/DCS/EPCS BELL OPERATION During CTCSS Decode, DCS, or EPCS operation, you may set up the VX-8GR so that a ringing “bell” sound alerts you that a call is coming in. Here is the procedure for activating the CTCSS/DCS/EPCS Bell: 1. Set the operating frequency to the desired channel. 2. Set the transceiver up for CTCSS Decode (“Tone Squelch”), DCS, or EPCS operation, as described previously. 3. Press and hold the m key for one second to enter the Set Mode. 4. Rotate the DIAL knob to select Set Mode Item 13: BELL SELECT SELECT. 5. Press the m key briefly to enable adjustment of this Set Mode Item. 6. Rotate the DIAL knob to set the desired “bell” sound. The available choices are BELL BELL, USER BP1 BP1, USER BP2 BP2, USER BP3 BP3, or OFF (disable the Bell function). Note: When User Beep (described later) does not register, USER BP1 BP1, USER BP2 BP2, or USER BP3 does not appear. 7. Press the m key briefly, then rotate the DIAL knob one click counter-clockwise to select Set Mode Item 12: BELL RINGER RINGER. 8. Press the m key briefly to enable adjustment of this Menu Item. 9. Rotate the DIAL knob to set the desired number of rings of the Bell. The available choices are 1Time through 20Times or CONTINUOUS CONTINUOUS. 10. Press the PTT switch briefly to save the new setting and exit to normal operation. When you are called by a station whose transceiver is sending a CTCSS tone, DCS code, or CTCSS tone pair which matches that set into your Decoder, the Bell will ring in accordance with this programming. When the CTCSS/DCS/EPCS Bell is activated, the “ will appear in the display. ” icon To disable the CTCSS/DCS/EPCS Bell function, select the setOFF OFF”. ting of Set Mode Item 11: BELL SELECT to “OFF VX-8GR OPERATING MANUAL 37 FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION CTCSS/DCS/EPCS BELL OPERATION PROGRAMMING THE USER MELODY Three User Beep Memories are provided, allowing you to create unique original beep tone melodies. C1 B3 Each User Beep Memory can store up to 64 steps with three octaves (“C1 C1” through “B3 B3”). 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 10: BEEP MELODY MELODY. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the memory slot into which you wish to store your programmed beep melody. Available selections are 1, 2, and 3. The previously stored beep melody will be displayed. 5. Press the M key to enable programming the beep melody. Press and hold the h key for one second to clear any previous beep melody, if desired. 6. Rotate the DIAL knob to select the first beep tone of the Operation Mode User Beep Melody. Available selections are C1 - B3 B3, and Step POS (rest). 7. Press the M key, then rotate the DIAL knob to set the length of the first beep tone. Available selections are 10ms (10 msec) - 2500ms (2.5 sec). 8. Press the M key to accept the first beep tone of the User Beep Tone Beep Melody. Memory Slot Tone Length 9. If you make a mistake, press the B key to back-space the cursor, then re-enter the correct beep tone or length. 10. Repeat steps 6 - 9 until you have completed the User Beep Melody. 11. When there is a beep tone, which you wish to delete, bring the cursor to that beep tone using the B/M key, then SELECT press the c key repeatedly until the “SELECT SELECT” notation DELETE in the “Operation Mode” slot turns into “DELETE DELETE”. Now, press and hold in the c key for one second to delete that beep tone. C1 D1 E1 F1 G1 A1 B1 C2 D2 E2 F2 G2 A2 B2 C3 D3 E3 F3 G3 A3 B3 38 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION CTCSS/DCS/EPCS BELL OPERATION 12. When you wish to add a beep tone into the beep melody strings, move the cursor to the place where you wish to enter the beep tone using the B/M key, then press the SELECT c key repeatedly until the “SELECT SELECT” notation in the “OpINSERT INSERT”. Now, press and hold in the c key for one eration Mode” slot turns into “INSERT second to add the new beep tone (Tone: “C2”, Tone Length: “500mS”). 13. Press and hold the h key for one second to delete all data after the current position that may have previously been stored in the User Beep Melody. 14. When you have programmed User Beep Melody, press the PTT switch briefly to save the new setting and exit to normal operation. You may check your work by monitoring the programmed User Beep Melody. To do this, repeat steps 1 - 4 above, then press the f key. SPLIT TONE OPERATION The VX-8GR can be operated in a Split Tone configuration via the Set mode. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 87: SQL SPLIT SPLIT. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON” (to enable the Split Tone feature). 5. Press the PTT switch briefly to save the new setting and exit to normal operation. When the Split Tone feature is activated, you can see the following additional parameters MESSAGE after the “MESSAGE MESSAGE” parameter while selecting the Set Mode Item 88: SQL TYPE TYPE: DC DCS Encode only (“DC DC” icon will appear while operating) Encodes a CTCSS Tone and Decodes a DCS code T-D (the “T-D T-D” icon will appear during operation) D CD-TONE SQL SQL: Encodes a DCS code and Decodes a CTCSS Tone D-T (the “D-T D-T” icon will appear during operation) D CD CD: TONE-DCS TONE-DCS: Select the desired operating mode from the selections shown above. VX-8GR OPERATING MANUAL 39 FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION CTCSS/DCS/EPCS VIBRATOR OPERATION The CTCSS/DCS/EPCS Vibrator operation is similar to the CTCSS/DCS/EPCS BELL operation. The CTCSS/DCS/EPCS Vibratory operation inform you that a call is coming in by vibration, during CTCSS Decode, DCS, or EPCS operation. Here is the procedure for activating the CTCSS/DCS/EPCS Vibrator: 1. Set the operating frequency to the desired channel. 2. Set the transceiver up for CTCSS Decode (“Tone Squelch”), DCS, or EPCS operation, as described previously. 3. Press and hold the m key for one second to enter the Set Mode. 4. Rotate the DIAL knob to select Set Mode Item 97: VIBRATOR TOR. 5. Press the m key briefly to enable adjustment of this Set Mode Item. SIGNALING 6. Rotate the DIAL knob to select “SIGNALING SIGNALING”. BUSY Note: When this item is set to “BUSY BUSY”, the VX-8GR vibrates just to have received a signal without affecting the CTCSS, DCS, or EPCS decoder. 7. Press the m key briefly, then rotate the DIAL knob one click clockwise to select Set Mode Item 98: VIBRATOR MODE MODE. 8. Press the m key briefly to enable adjustment of this Menu Item. 9. Rotate the DIAL knob to set the desired vibrating mode. The available choices are: MODE1 MODE1: The VX-8GR vibrates continuously. MODE2 MODE2: The VX-8GR vibrates at a long interval. MODE3 MODE3: The VX-8GR vibrates at a short interval. 10. Press the PTT switch briefly to save the new setting and exit to normal operation. When you are called by a station whose transceiver is sending a CTCSS tone, DCS code, or CTCSS tone pair which matches that set into your Decoder, the VX-8GR will vibrate in accordance with this programming. When the CTCSS/DCS/EPCS Vibrator operation is activated, the “dashed line” will appear under the mode icon. To disable the CTCSS/DCS/EPCS Vibrator operation, select the OFF setting of Set Mode Item 97: VIBRATOR to “OFF OFF”. 40 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CTCSS/DCS/EPCS OPERATION TONE CALLING (1750 HZ) If the repeaters in your country require a 1750-Hz burst tone for access (typically in Europe), you can set the e key to serve as a “Tone Call” switch instead. To change the configuration of this switch, we again use the Menu to help us. 1. Press and hold the m key for one second to enter the Set Mode. T2. Rotate the DIAL knob to select Set Mode Item 56: MONI MONI/TCALL CALL. 3. Press the m key briefly to enable adjustment of this Set Mode Item. T-CALL 4. Rotate the DIAL knob to select “T-CALL T-CALL” on the display. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. To access a repeater, press and hold in the e key for the amount of time specified by the repeater owner/operator. The transmitter will automatically be activated, and a 1750-Hz audio tone will be superimposed on the carrier. Once access to the repeater has been gained, you may release the e key, and use the PTT switch for activating the transmitter. VX-8GR OPERATING MANUAL 41 FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE The VX-8GR provides a wide variety of memory system resources. These include: “Regular” Memory Channels, which include: 1” through “900 900 900 “Standard” memory channels, numbered “1 900.” 901 999 99 “Frequency Skip Memories,” numbered “901 901” through “999 999.” 7 “Home” channels, providing storage and quick recall of one prime frequency on each operating band. 50 sets of band-edge memories, also known as “Programmable Memory Scan” L01 U01 L50 U50 channels, labeled “L01 L01/U01 U01” through “L50 L50/U50 U50.” b1 b24 24 Memory Banks, labeled “b 1” through “b24 b24.” Each Memory Bank can be assigned up to 100 channels from the “regular” memory channels. Special Memory Channels, which include: One “Emergency Automatic ID (EAI)” Channel. 10 “Weather Broadcast” Channels. 57 VHF Marine Channels. Info. Band-2 UHF Band VHF Band Info. Band-1 Air Band VHF Marine Channels (57 channels) WX9 WX10 WX4 WX1 WX2 WX3 Weather Broadcast Channels (10 channels) 42 L49/U49 L50/U50 L1/U1 L2/U2 998 999 904 902 903 901 HOME Channels (7 channels) EAI EAI Channel (1 channel) L3/U3 L4/U4 PMS Memory Channels (50 Sets) Frequency Skip Memory Channels (99 channels) 900 889 Standard Memory Channels (900 channels) VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MEMORY STORAGE 1. Select the desired frequency, while operating in the VFO mode. Be sure to set up any desired CTCSS or DCS tones, as well as any desired repeater offset. The power level may also be set at this time, if you wish to store it. 2. Press and hold in the f key for 1/2 second. 3. Within five seconds of releasing the f key, you need to make a decision regarding channel storage. The microprocessor will automatically select the next-available “free” channel (a memory register on which no data has been stored). If you do not wish to make a change and accept the “free” channel, proceed to step 4. If you wish to select a different channel number into which to store the data, rotate the DIAL knob to select the desired memory channel. Advice: You may jump 100 memory channels, if you’re in a hurry (101 201 301 …), by pressing the m key (multiple times, if necessary). If you see the “ ” icon at the upper left of the channel number, it means that the channel currently has no data written on it (i.e. the channel is “free”: the occupied channel displays the “ ” icon). 4. Press the f key once more to store the frequency into memory. 5. You still will be operating in the “VFO” mode, so you may now enter other frequencies, and store them into additional memory locations, by repeating the above process. 1) You may change the automatic memory channel selection feature to select the “next-highest memory channel above the last-stored memory channel” instead of the “next-available ‘free’ channel” via the Set Mode Item 51: MEMORY WRITE; see page xx. 2) You may disable the memory write function which prevents a memory write operation if you should accidentally perform a wrong key sequence via the Set Mode Item 49: MEMORY PROTECT. See page xx for details. When the memory write protect is activated, the “PROTECT” notation appears on the display while a memory write operation is being performed. 3) You may change the duration time of the secondary function (press and holding the key) of the f key via the Set Mode Item 31: FW KEY HOLD TIME; see page xx. IMPORTANT NOTE On rare occasions the memorized data may become corrupted by miss operation, or static electricity. When repairs are made the memory data may be lost. Please write down or record the memorized information so you will be able to restore it if needed. VX-8GR OPERATING MANUAL 43 FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MEMORY STORAGE STORING INDEPENDENT TRANSMIT FREQUENCIES (“ODD SPLITS”) All memories can store an independent transmit frequency, for operation on repeaters with non-standard shift. To do this: 1. Store the receive frequency using the method already described under MEMORY STORAGE (it doesn’t matter if a repeater offset is active). 2. Tune to the desired transmit frequency, then press and hold in the f key for 1/2 second. 3. Within five seconds of releasing the f key, rotate the DIAL knob to select the same memory channel number as used in step “1” above. 4. Press and hold in the PTT switch, then briefly press the f key once more while holding the PTT switch in (this does not key the transmitter). Whenever you recall a memory, which contains independently-stored transmit and receive frequencies, the “ ” indication will appear in the display. MEMORY RECALL 1. While operating in the VFO mode, press the c key to enter the Memory mode. 2. Rotate the DIAL knob to select the desired channel. 3. If you press the f key briefly, then rotate the DIAL knob, the memory channel will be selected in 10 channels per step. 4. To return to the VFO mode, press the c key. 1) When the radio is already set to the Memory mode, an easy way to recall memories is to key in the memory channel number, then press the c key. For example, to recall memory channel #14, press 14 c. 2) You may change the step of the fast channel selection mode (f key + DIAL knob) via Set Mode Item 47: MEMORY FAST STEP. See page xx for details. 44 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) HOME CHANNEL MEMORY A special one-touch “HOME” channel is available for each operating band, to allow quick recall of a favorite operating frequency on each band. HOME CHANNEL RECALL 1. Press the f key, then press the h key to recall the Home Channel on the band group where you are currently operating. 2. Press the f key, then press the h key again to return to the previously-used frequency (either a VFO or a memory channel). The transceiver switches to VFO mode if the DIAL knob is turned. You may disable the above function (automatically switching to the VFO mode) using Set Mode Item 33: HOME VFO. HOME CHANNEL FREQUENCY CHANGE The factory defaults for the Home channels are listed below. You may re-program the Home channel in a manner identical to that used for the regular memories: 1. Select the desired frequency, while operating in the VFO mode. Be sure to set up any desired CTCSS or DCS tones, as well as any desired repeater offset. The power level may also be set at this time, if you wish to store it. 2. Press and hold in the f key for 1/2 second. 3. While the memory channel number is blinking, just press the h key. The frequency and other data (if any) will now be stored in the special HOME channel register. 4. You may repeat this process on the other operating bands. Note that the UHF HOME channel is the one used during “Emergency” operation. See page xx for details regarding this feature. DEFAULT HOME CHANNELS OPERATING BAND [BAND NUMBER] Air Band VHF HAM Band VHF Band Information Band 1 UHF HAM Band UHF Band Information Band 2 VX-8GR OPERATING MANUAL [1] [2] [3] [4] [5] [6] [7] FREQUENCY USA VERSION EXP VERSION 108.000 MHz 108.000 MHz 146.520 MHz 144.000 MHz 174.000 MHz 174.000 MHz 222.000 MHz 222.000 MHz 446.000 MHz 430.000 MHz 470.000 MHz 470.000 MHz 860.000 MHz 860.000 MHz 45 FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) LABELING MEMORIES You may wish to append an alpha-numeric “Tag” (label) to a memory or memories, to aid in recollection of the channel’s use (such as a club name, etc.). This is easily accomplished using the Set Mode. 1. Recall the memory channel on which you wish to append a label. 2. Press and hold the m key for one second to enter the Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 48: MEMORY NAME NAME. 4. Press the m key briefly to enable programming of the name tag. Press and hold the h key for two seconds to clear any previous name, if desired. 5. Rotate the DIAL knob, or press one of the keyboard keys, to select the first digit of the desired label. Example 1: Rotate the DIAL knob to select any of the 61 available characters. Example 2: Press the 8 key repeatedly to toggle among the seven available characters associated with that key: t u v 8 T U V 6. Press the M key to move to the next character, if needed. 7. Repeat steps 5 and 6 to program the remaining letters, numbers, or symbols of the desired label. A total of 16 characters may be used in the creation of a label. 8. Press and hold the h key for two seconds to delete all data after the cursor that may have been previously stored. 9. If you make a mistake, press the B key to backspace the cursor, then re-enter the correct letter, number, or symbol. 10. When you have completed the creation of the label, press the PTT switch briefly to save the label and exit to normal operation. During Memory Recall (“MR”) with Mono Band operation, the alphanumeric Tag will appear below the frequency display. The alphanumeric Tag does not appear if you activate the Dual Receive Operation. 46 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MEMORY OFFSET TUNING Once you have recalled a particular memory channel, you may easily tune off that channel, as though you were in the “VFO” mode. 1. With the VX-8GR in the Memory Recall (“MR”) mode, select the desired memory channel. MR 2. Now press the f key, then press c key. The “MR MR” inTUN dicator will be replaced by one which says “TUN TUN” (“Memory Tuning”). 3. Rotate the DIAL, as desired, to tune to a new frequency. The synthesizer steps selected for VFO operation on the current band will be the steps used during Memory Tuning. 4. If you wish to return to the original memory frequency, press c key briefly. The TUN MR “TUN TUN” indicator will be replaced by “MR MR.” 5. If you wish to store a new frequency set during Memory Tuning, just press and hold in the f key for one second, per normal memory storage procedure. The microprocessor will automatically set itself to the next-available clear memory location, and you then press the f key again, briefly to lock in the new frequency. If you want to replace the original memory contents with the new frequency settings, be sure to rotate the DIAL to the original memory channel number! Any required CTCSS/DCS changes, or repeater offset modifications, must be done before storing the data into the new (or original) memory channel location. VX-8GR OPERATING MANUAL 47 FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MASKING MEMORIES There may be situations where you want to “Mask” memories so they are not visible during memory selection or scanning. For example, several memories used only in a city you visit infrequently may be stored, then “Masked” until you visit that city, at which time you can “Unmask” them for normal use (except for Memory Channel “1”). 1. Press the c key, if needed, to enter the Memory Recall (“MR”) mode. 2. Press and hold in the f key for 1/2 second, then rotate the DIAL to select the memory channel to be “Masked” from view. MR MASK? 3. Press the d key. The confirmation message (MR MASK?) will appear on the display. Press the d key once more, the display will revert to memory channel #1. If you rotate the DIAL to the location you just “Masked,” you will observe that it is now invisible. 4. To Unmask the hidden memory, repeat the above procedure: press and hold in the f key for 1/2 second, rotate the DIAL to select the masked memory’s number, then press the d key to restore the memory channel’s data. Watch out! You can manually store data over a “Masked” memory, deleting previous data, if you’re not careful. Use the “next available memory” storage technique to avoid over-writing a masked memory. 48 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MEMORY BANK OPERATION The large number of memories available in the VX-8GR could be difficult to utilize without some means of organizing them. Fortunately, the VX-8GR includes provision for dividing the memories into as many as 24 Memory Banks, so you can categorize the memories in a manner convenient to you. You may enter and exit the “Memory Bank” mode by a single press of the B key, as we shall see below. ASSIGNING MEMORIES TO A MEMORY BANK 1. Recall the memory channel to be assigned to a Memory Bank. 2. Press and hold in the f key for 1/2 second, then rotate the DIAL knob to select the Memory Bank number where you want to include this channel (Memory Bank numbers are 1”). The “ ” icon will apfound before memory channel “1 pear at the upper left of the Memory Bank number if some channels have already been assigned to that Memory Bank number. (If no channels are assigned to the Memory Bank, the “ ” icon appears on the left of the Memory Bank number). 3. Press the f key briefly. Memory Bank “1” Memory Channel 144 MHz Amateur Band Channels 4. At this point, the memory CH 1 145.000 MHz CH 2 145.080 MHz CH 435.000 MHz channel data is copied into Memory Bank “2” CH 4 435.500 MHz 430 MHz Amateur Band Channels CH 5 145.800 MHz the Memory Bank. CH 6 436.000 MHz CH 7 128.800 MHz Memory Bank “3” All Amateur Band Channels 1) You may assign one memory chanMemory Bank “4” Club Channels n e l i n t o s e v e r a l CH 897 145.620 MHz CH 898 436.780 MHz Memory Bank “5” Memory Banks. CH 899 128.600 MHz Air Band Channels 2) The PMS memory channels (L1/U1 through L50/U50) may not be assigned to a Memory Bank. MEMORY BANK RECALL 1. Press the c key, if needed, to enter the MR mode. 2. Press the B key to activate the “Memory Bank” mode. MR The “MR MR” indicator will be replaced by one of the Memory B1 B24 Bank numbers (“B 1” through “B24 B24”). 3. Press the f key, and then press the B key, then rotate the DIAL knob to select the desired Memory Bank. 4. Press the B key. Now, as you rotate the DIAL knob to select memories, you will observe that you can only select memory channels in the current Memory Bank. VX-8GR OPERATING MANUAL 49 FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MEMORY BANK OPERATION 5. To change to another Memory Bank, press the f key, then press the B key. Now rotate the DIAL knob to select the new Memory Bank, then press the B key again. 6. To exit from Memory Bank operation, just press the B key. The Memory Bank MR MR”, and you are now in the “regular” Memory number will be replaced by the “MR Recall mode, without utilization of the Memory Banks. The memories stored in the various Banks will remain in those banks. You do not need to store them again. REMOVING MEMORIES FROM A MEMORY BANK 1. Recall the memory channel to be removed from a Memory Bank. 2. Press and hold the f key for 1/2 second, then press the d key to remove the memory channel data from the Memory bank. CHANGING A MEMORY BANK’S NAME You may change the default Memory Bank Names, which are shown on the display while selecting the Memory Bank your desire. 1. Press and hold in the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select the Set Mode Item 6: BANK NAME NAME. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the memory bank on which you wish to change a label. 5. Press the M key briefly to enable changing of the name tag. Press and hold the h key for two seconds to clear any previous name, if desired. 6. Rotate the DIAL knob, or press one of the keyboard keys, to select the first digit of the desired label. Example 1: Rotate the DIAL knob to select any of the 61 available characters. Example 2: Press the 2 key repeatedly to toggle among the seven available characters associated with that key: a b c 2 A B C 7. Press the M key to move to the next character, if needed. 8. Repeat steps 6 and 7 to program the remaining letters, numbers, or symbols of the desired label. A total of 16 characters may be used in the creation of a label. 9. Press and hold the key for two seconds to delete all data after the cursor that may have been previously stored. 50 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (REGULAR MEMORY CHANNEL OPERATION) MEMORY BANK OPERATION 10. If you make a mistake, press the B key to backspace the cursor, then re-enter the correct letter, number, or symbol. 11. When you have completed the changes of the label, press the PTT switch to save the label and exit. MOVING MEMORY DATA TO THE VFO Data stored on memory channels can easily be moved to VFO, if you like. 1. Press the c key, if needed, to enter the Memory Recall (“MR”) mode. 2. Press and hold in the f key for 1/2 second, then rotate the DIAL knob to select the memory channel containing the frequency data to be moved to VFO. OVER3. Press the c key. The confirmation message (OVERWRITE? WRITE?) will appear on the display. Press the c key once more, the data will now have been copied to VFO, although the original memory contents will remain intact on the previously stored channel. Press the PTT switch to cancel the Moving Memory Data procedure, if desired. If a Split Frequency Memory channel was transferred, the Tx frequency will be ignored (you will be set up for Simplex operation on the Receive frequency). MEMORY ONLY MODE Once memory channel programming has been completed, you may place the radio in a “Memory Only” mode, whereby VFO operation is impossible. This may be particularly useful during public-service events where a number of operators may be using the radio for the first time, and ultimate simplicity of channel selection is desired. To place the radio into the Memory Only mode, turn the radio off. Now press and hold in the c key while turning the radio on. To return to normal operation, repeat the above power-on procedure. VX-8GR OPERATING MANUAL 51 FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (SPECIAL MEMORY CHANNEL OPERATION) The VX-8GR provides Special Memory Channels, which are made up of: 10 Weather Broadcast Channels. 57 VHF Marine Channels 1) The Special Memory Channels are only recalled on the “A-Band” 2) You may assign the Special Memory Channels to a Memory Bank. See page xx regarding Memory Bank Operation for details. WEATHER BROADCAST CHANNELS The VHF Weather Broadcast Station Memory Channel Bank has been pre-programmed at the factory, for quick selection of NOAA weather information stations. 1. Press the a key briefly to set the “A-Band” to the “Operating” band. 2. Press the f key, then press the 9 key, to recall the Special Memory Menu. 3. Press the B key, repeatedly if necessary to select the WX CH “WX CH” (thus recalling the Weather Broadcast Memory Bank). 4. Rotate the DIAL knob to select the desired Weather Broadcast channel. 5. If you wish to scan this bank to search for louder stations, just press the PTT switch. When the scanner pauses on a station, press the PTT switch once to halt the scan, or press it twice to restart the scan. 6. To exit to normal operation, press the c key, or press f key followed by the 9 key. In the event of extreme weather disturbances, such as storms and hurricanes, the NOAA (National Oceanic and Atmospheric Administration) sends a weather alert accompanied by a 1050 Hz tone and subsequent weather report on one of the NOAA weather channels. You may disable the Weather Alert tone via Set Mode Item 100: WX ALERT, if desired. See page xx. CH 52 WX CHANNEL FREQUENCY LIST FREQUENCY CH FREQUENCY 162.550 MHz 6 162.500 MHz 162.400 MHz 7 162.525 MHz 162.475 MHz 8 161.650 MHz 162.425 MHz 9 161.775 MHz 162.450 MHz 10 163.275 MHz VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MEMORY MODE (SPECIAL MEMORY CHANNEL OPERATION) VHF MARINE MEMORY CHANNELS The VHF Marine Channel Bank has been pre-programmed at the factory, for quick selection. 1. Press the a key briefly to set the “A-Band” to the “Operating” band. 2. Press the f key, then press the 9 key, to recall the Special Memory Menu. 3. Press the B key, repeatedly if necessary to select the INTVHF “INTVHF INTVHF” (thus recalling the VHF Marine Channel Bank). 4. Rotate the DIAL to select any of the 57 available VHF Marine Channels. 5. Press the h key to monitor the duplex frequency while recalling a semi-duplex channel (such as Channel “1”). Press the h key again to revert to simplex monitoring. 6. To exit to normal operation, press the c key, or press f key followed by the 9 key. VHF MARINE CHANNEL FREQUENCY LIST CH No. 10 11 12 13 14 15 FREQUENCY (MHz) 156.050 160.650 156.100 160.700 156.150 160.750 156.200 160.800 156.250 160.850 156.300 156.350 160.950 156.400 156.450 156.500 156.550 156.600 156.650 156.700 156.750 CH No. 16 17 18 19 20 21 22 23 24 25 26 27 28 FREQUENCY (MHz) 156.800 156.850 156.900 161.500 156.950 161.550 157.000 161.600 157.050 161.650 157.100 161.700 157.150 161.750 157.200 161.800 157.250 161.850 157.300 161.900 157.350 161.950 157.400 162.000 VX-8GR OPERATING MANUAL CH No. 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 FREQUENCY (MHz) 156.025 160.625 156.075 160.675 156.125 160.725 156.175 160.775 156.225 160.825 156.275 160.875 156.325 160.925 156.375 156.425 156.475 156.525 156.575 156.625 156.675 156.725 CH No. 75 76 77 78 79 80 81 82 83 84 85 86 87 88 FREQUENCY (MHz) 156.775 156.825 156.875 156.925 161.525 156.975 161.575 157.025 161.625 157.075 161.675 157.125 161.725 157.175 161.775 157.225 161.825 157.275 161.875 157.325 161.925 157.375 161.975 157.425 162.025 53 FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING GENERAL The VX-8GR allows you to scan just the memory channels, the entire operating band, or a portion of that band. It will halt on signals encountered, so you can talk to the station(s) on that frequency, if you like. Scanning operation is basically the same in each of the above modes. Before you begin, take a moment to select the way in which you would like the scanner to resume scanning after it halts on a signal. SETTING THE SCAN-RESUME TECHNIQUE Three options for the Scan-Resume mode are available: 10.0sec: In this mode, the scanner will halt on a signal it encounters, and will 2.0sec - 10.0sec hold there for the selected resume time. If you do not take action to disable the scanner within that time period, the scanner will resume even if the station is still active. BUSY BUSY: In this mode, the scanner will halt on a signal it encounters. When the carrier has dropped because the other station ceased transmission, the scanner will resume. In the case of constant-carrier signals like Weather Station broadcasts, the scanner will likely remain on this frequency indefinitely. The Scan Re-start Delay time (default interval: 2 seconds) is set by Set Mode Item 76: SCAN RE-START RE-START. HOLD HOLD: In this mode, the scanner will halt on a signal it encounters. It will not restart automatically; you must manually re-initiate scanning if you wish to resume. To set the Scan-Resume mode: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 77: SCAN RESUME RESUME. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired scan-resume mode. 5. Press the PTT switch to save the new setting and exit to normal operation. The default condition for this Set Mode Item is “5.0sec”. 54 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING GENERAL To set the Scan-Restart Delay Time: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 76: SCAN RE-START RE-START. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired Scan-Restart Delay Time. Available selections are 0.1sec - 0.9sec (0.1sec/step) and 1.0sec - 10.0sec (0.5sec/step). 5. Press the PTT switch to save the new setting and exit to normal operation. The default condition for this Set Mode Item is “2.0sec”. VX-8GR OPERATING MANUAL 55 FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING VFO SCANNING This mode allows you to scan on the VFO mode. 1. Select the VFO mode by pressing the c key, if necessary. 2. Press and hold in the B key, then rotate the DIAL knob while holding in the B key (the current bandwidth for the VFO scanner will appear on the display) to select the bandwidth for the VFO scanner. Available selections are ±1 MHz MHz, ±2 MHz MHz, ±5 MHz BAND, ALL ALL, and PMS-X PMS-X. MHz, BAND ±1 MHz MHz, ±2 MHz MHz, ±5 MHz MHz: The scanner will sweep frequencies within the selected bandwidth. BAND BAND: The scanner will sweep frequencies only on the current band. ALL ALL: The scanner will sweep all frequencies between 108 MHz and 999.99 MHz. PMS-X PMS-X: The scanner will sweep frequencies within the currently-selected PMS frequency pair. See page xx for details. 3. Release the B key to start scanning. 4. When the scanner encounters a signal strong enough to open the squelch, the scanner will halt temporarily; the decimal point of the frequency display will blink during this “Pause” condition. 5. The scanner will then resume according to the Scan-Resume mode selected in the previous section. 6. To cancel scanning, press the PTT switch or c key. 1) If you want to change direction of the scan while it is underway, rotate the DIAL knob one click in the opposite direction. You’ll see the scanner turn around and change frequency downward! 2) You may change the scanner’s method of operation so the VFO frequency will jump to the low band edge of the next band when the VFO frequency reaches the high edge of the current band (or vice versa). See page xx regarding Set Mode Item 95: VFO MODE. 56 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING VFO SCANNING HOW TO SKIP (OMIT) A FREQUENCY DURING VFO SCAN If the VFO scan stops on a frequency or frequencies that you do not need (such as a spurious radiation from a television), such frequencies can be “skipped” during VFO scanning. A special “Frequency Skip Memory” bank is reserved to store these frequencies. To skip a frequency during VFO scanning: 1. While VFO scanning is stopped on the frequency that you do not need, press and hold the f key for one second, then rotate the DIAL knob to select the desired Fre900 - 999 quency Skip Memory channel (900 999). The microprocessor will automatically select the next-available “free” Frequency Skip Memory channel (a memory register on which no data has been stored). If you see the “ ” icon at the upper left of the channel number, it means that the channel currently has no data written on it (i.e. the channel is “free”). 2. Press the f key to store the frequency into the Frequency Skip Memory. It will now be ignored during VFO scanning. To re-institute a frequency into the VFO scan loop: 1. Press the c key, if needed, to enter the Memory Recall (“MR”) mode. 2. Press and hold in the f key for one second, then rotate the DIAL knob to select the memory channel to be re-instituted. 3. Press the d key to delete the channel from the Frequency Skip Memory; this will restore the frequency into the VFO scan loop. The VX-8GR has 100 VFO Frequency Skip Memory Channels. SETTING THE SQUELCH LEVEL DURING ACTIVE SCANNING OPERATION The VX-8GR allows adjustment of the Squelch level “on the fly” while you are scanning. 1. While the scanner is engaged, press the key, key (the current squelch level then press the will appear below the frequency display). 2. Rotate the DIAL to select the desired Squelch level. 3. Press the PTT switch briefly to save the new setting and exit to normal operation. In this case, pressing the PTT switch this one time will not causing scanning to stop. VX-8GR OPERATING MANUAL 57 FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING MEMORY SCANNING Memory scanning is also easy to initiate: 1. Set the radio to the Memory Recall (“MR”) mode by pressing the c key, if necessary. 2. Press and hold in the B key, then rotate the DIAL knob while holding in the B key (the current Memory Scan mode will appear on the frequency display) to select the desired Memory Scan mode. Available selections are ALL CH CH, TAG1 TAG1, TAG2 TAG2, BAND BAND, and PMS-X PMS-X. ALL CH CH: The scanner sweeps all Memory channels. TAG1 TAG1: The scanner sweeps only those Memory channels with the same first digit of the alpha/numeric tag as the first channel on which scanning started. TAG2 TAG2: The scanner sweeps only those Memory channels with the same first and second digits of the alpha/numeric tag as the first channel on which scanning started. BAND BAND: The scanner sweeps only those Memory channels which are memorized on the same operating band as the first channel on which scanning started. PMS-X PMS-X: The scanner will sweep frequencies within the currently-selected PMS frequency pair. See page xx for details. 3. Release the B key to start scanning. 4. As with VFO scanning, the scanner will halt on any signal encountered that is strong enough to open the squelch; it will then resume scanning according to the Scan-Resume mode set previously. When there are no memory channels corresponding to the MS ERR selected Memory Scan mode, the “MS ERR” notation will appear on the display. 5. To cancel scanning, press the PTT switch or c key. 58 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING MEMORY SCANNING HOW TO SKIP (OMIT) A CHANNEL DURING MEMORY SCAN As mentioned previously, some continuous-carrier stations like a Weather Broadcast station will seriously impede scanner operation if you are using the “Carrier Drop” ScanResume mode, as the incoming signal will not pause long enough for the transceiver to resume scanning. Such channels may be “Skipped” during scanning, if you like: 1. Recall the Memory Channel to be skipped during scanning. 2. Press the f key, then press the 5 key to appear a small “” icon at the left of the frequency display. The current Memory Channel will now be ignored (skipped) during scanning (the “skipped” channel will, of course, still be accessible via manual channel selection methods using the DIAL knob in the Memory Recall (“MR”) mode, whether or not it is locked out of the scanning loop). To re-institute a channel into the scanning loop, press the f key followed by the 5 key twice, to disappear the small “” icon from display. Note: You may notice a blinking “” icon while you perform above procedure. It indicates the “Preferential Memory Scan” channel, described in the next column. PREFERENTIAL MEMORY SCAN The VX-8GR also allows you to set up a “Preferential Scan List” of channels which you can “flag” within the memory system. These channels are designated by a blinking “” icon when you have selected them, one by one, for the Preferential Scan List. When you initiate memory scanning on a channel with the blinking “” icon appended, only those channels bearing the blinking “” icon will be scanned. If you initiate scanning on a channel which does not have the blinking “” icon appended, you will scan all channels including those with the blinking “” icon appended. Here is the procedure for setting up and using the Preferential Scan List: 1. Recall the Memory Channel which you wish to add to the Preferential Scan List. 2. Press the f key followed by the 5 key until a blinking small “” icon appears at the left of the frequency display. To clear the memory channel from the “Preferential Scan List”, press the f key followed by the 5 key to disappear the blinking small “” icon from display. VX-8GR OPERATING MANUAL 59 FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING MEMORY SCANNING To initiate Preferential Memory Scan: 1. Press the c key briefly to enter the Memory Recall (“MR”) mode, if you are not using memories already. 2. Rotate the DIAL knob to select any channel which has a blinking “” icon appended to the channel number. 2. Press and hold in the B key, then rotate the DIAL knob while holding in the B key (the current Memory Scan mode will appear on the frequency display) to select the desired Memory Scan mode. Available selections are ALL CH(ONLY), TAG1(ONLY), TAG2(ONLY), BAND(ONLY), and PMS-X PMS-X. ALL CH CH: The scanner sweeps all Preferential Scan Channels. TAG1 TAG1: The scanner sweeps only those Preferential Scan Channels with the same first digit of the alpha/numeric tag as the first channel on which scanning started. TAG2 TAG2: The scanner sweeps only those Preferential Scan Channels with the same first and second digits of the alpha/numeric tag as the first channel on which scanning started. BAND BAND: The scanner sweeps only those Preferential Scan Channels which are memorized on the same operating band as the first channel on which scanning started. PMS-X PMS-X: The scanner will sweep frequencies within the currently-selected PMS frequency pair. This is not a Preferential Memory Scan, see page ?? for details. 3. Release the B key to start scanning. When there are no memory channels corresponding to the selected Memory Scan MS ERR mode, the “MS ERR” notation will appear on the display. 5. To cancel scanning, press the PTT switch or c key. 60 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING MEMORY SCANNING MEMORY BANK SCAN When the Memory Bank feature is engaged, the scanner sweeps only memory channels in the current Memory Bank. However, if the Memory Bank Link Scan feature is enabled, you may sweep the memory channels in several Memory Banks which you have selected. To enable the Memory Bank Link Scan feature: 1. Set the radio to the Memory Recall (“MR”) mode by pressing the c key, if necessary. 2. Press the B key to activate the “Memory Bank” mode. MR The “MR MR” indicator will be replaced by one of the Memory B1 B24 Bank numbers (“B 1” through “B24 B24”). 3. Press the f key followed by the B key. The Memory Bank number will begin to blink. 4. Rotate the DIAL knob to select the first Memory Bank BANK 1 BANK24 (“BANK 1” ~ “BANK24 BANK24”) you wish to sweep using Memory Bank Link Scan. B-LINK ON 5. Press the c key briefly. A “B-LINK ON” notation will appear for two seconds on the display, indicating this Memory Bank will now be swept during Memory Bank Scan. B-LINK ON 6. Repeat steps 4 and 5 above, to append the “B-LINK ON” notation to any other Memory Banks you wish to sweep. 7. Press the B key. 8. Now, press and hold in the B key for one second to initiate the Memory Bank Link Scan. 9. To remove a Memory Bank from the Memory Bank Link Scan, repeat steps 1 - 5 B-LINK ON B-LINK OFF above, to change the “B-LINK ON” notation into “B-LINK OFF”. 1) When the Memory Bank is enabled for Memory Bank scan, the Memory Bank number (“B x”) indication turns into “bx” (capital “B” turns into small “b”). 2) You may enable/disable the Memory Bank scan via Set Mode Item 5: BANK LINK. MEMORY BANK SCAN “DISABLED” VX-8GR OPERATING MANUAL 61 FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING PROGRAMMABLE (BAND LIMIT) MEMORY SCAN (PMS) This feature allows you to set sub-band limits for either scanning or manual VFO operation. For example, you might wish to set up a limit (in North America) of 144.300 MHz to 148.000 MHz to prevent encroachment into the SSB/CW “Weak Signal” portion of the band below 144.300 MHz. Here’s how to do this: 1. Set the radio to the VFO mode by pressing the c key, if necessary. 2. Using the techniques learned earlier, store (per the above concept) 144.300 MHz into L1 (the “L” designates the Lower sub-band limit). Memory Channel #L1 U1 (the “U” designates the 3. Likewise, store 146.000 MHz into Memory Channel #U1 Upper sub-band limit). 4. Press and hold in the B key for one second and rotate the DIAL knob while holding in the B key to select the PMSxx desired PMS frequency pair (PMSxx PMSxx). 5. Release the B key to start scanning within the just-proVFO PMS grammed range. The “VFO VFO” label will be replaced by “PMS PMS” Pxx and the Band number will be replaced by “Pxx Pxx”. Tuning and scanning will now be limited within the just-programmed range. U1 through L50 U50 are available. 6. 50 pairs of Band Limit memories, labeled L1 L1/U1 L50/U50 You therefore can set upper and lower operation limits on a number of bands, if you like. 7. To exit to normal operation, press the c key. 62 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING “PRIORITY CHANNEL” SCANNING (DUAL WATCH) The VX-8DR’s scanning features include a two-channel scanning capability which allows you to operate on a VFO or Memory channel, while periodically checking a userdefined Memory Channel for activity. If a station is received on the Memory Channel which is strong enough to open the Squelch, the scanner will pause on that station in accordance with the Scan-Resume mode set via Menu Item 83: SCAN RESUME RESUME. See page 60. Here is the procedure for activating Priority Channel Dual Watch operation: 1. Press the c key briefly to enter the Memory Recall (“MR”) mode, if you are not using memories already. 2. Press and hold in the f key for one second, then rotate the DIAL knob to select the memory channel you wish to be the “Priority” channel. P” icon will appear to the right of 3. Press the B key. The “P MR the “MR MR” label, indicating it is the Priority channel. 4. Now set the VX-8GR for operation on another memory channel, or on a VFO frequency. 5. Press and hold in the c key for one second. The display will remain on the VFO or memory channel selected. However, every five seconds the VX-8GR will check the PriorMR ity Channel for activity. The “MR MR” label will be replaced by MDW VFO “MDW MDW” while operating on the Memory channel or the “VFO VFO” label will be replaced VDW by “VDW VDW” while operating on the VFO mode. 6. If a station appears on the Priority Channel, the radio will pause on that channel, as described previously. The receiving time interval (ratio) between the current channel (or VFO frequency) and Priority channel may be customized via Set Mode Item 67: PRI TIME TIME. To set the receiving time interval: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 62: PRI TIME TIME. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired time interval. Available selections are 0.1sec - 0.9sec (0.1sec/step) and 1.0sec - 10.0sec (0.5sec/step). 5. Press the PTT switch briefly to save the new setting and exit to normal operation. The default condition for this Set Mode Item is “5.0sec”. VX-8GR OPERATING MANUAL 63 FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING “PRIORITY CHANNEL” SCANNING (DUAL WATCH) PRIORITY REVERT MODE During Priority channel operation (Dual Watch), a special feature is available which will allow you to move to the Priority Channel instantly, without waiting for activity to appear on the Priority Channel. When this feature is enabled, and priority monitoring is engaged, just press the microphone’s PTT switch. Operation will instantly revert to the Priority Channel. To enable Priority Revert operation: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 66: PRI REVERT VERT. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON”. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. OFF To disable Priority Revert operation, select “OFF OFF” in step 4 above. 64 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SCANNING AUTOMATIC LAMP ILLUMINATION ON SCAN STOP The VX-8GR will automatically illuminate the LCD Lamp whenever the scanner stops on a signal; this allows you to see the frequency of the incoming signal better at night. Note that this will, of course, increase battery consumption, so be sure to switch it off during the day (the default condition for this feature is “ON”). The procedure for disabling the Scan Lamp is: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 75: SCAN LAMP LAMP. 3. Press the m key briefly to enable adjustment of this Set Mode Item. OFF 4. Rotate the DIAL knob to select “OFF OFF”. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. BAND EDGE BEEPER The VX-8GR will automatically “beep” when a band edge is encountered during scanning (either in standard VFO scanning or during PMS operation). You may enable this feature (band edge beeper) when the frequency reaches the band edge while selecting the VFO frequency by the DIAL knob. The procedure for enabling the Band-Edge Beeper is: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 8: BEEP EDGE EDGE. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON”. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. VX-8GR OPERATING MANUAL 65 FCC ID: K6620415X20 / IC:511B-20415X20 GPS OPERATION The VX-8GR allows the display of your position (Longitude/Latitude) with the built-in GPS Antenna Unit. 1. 2. 3. 4. 5. 6. 7. 3. 4. 5. Press the m key until the GPS screen appears. Press and hold in the m key for one second to enter the APRS/GPS Set Mode. Ratate the DIAL knob to select Set Mode Item 18: GPS POWER POWER. Press the m key briefly to enable selection of this Set Mode Item. Rotate the DIAL knob to select “GPS ON” (to activate the built-in GPS Antenna Unit). Press the PTT switch briefly to save the new setting and exit to normal operation. When the transceiver succeeds in receiving a valid GPS signal, your current position (Longitude/Latitude), current time (UTC), and altitude will appear on the display. Rotate the DIAL knob (or press the a/b key) to scroll through additional lines of station text on the display. The received satellite number appears at the lower right of compasses (In the example at the right, it is 4 satellites). When receiving a signal from more than 3 satellites, the “ ” icon will appear on the display. Advice: 1) When the built-in GPS Antenna Unit is first turned on, it may take several minutes to compute a fix of your position. This is normal, as the built-in GPS unit is downloading “almanac” information from the GPS satellites. 2) While the VX-8GR searches for a GPS signal, the compass icon does not appear on the display and the position information (Longitude/Latitude) blinks on the display. 3) If the VX-8GR does not receive a valid GPS signal after three minutes have passed, you may be in a poor location for satellite reception, such as inside of a house or building; try moving to a less obstructed position. If you walk a few meters from your current location, your course direction is displayed on the compass of the display SPD and walking speed is displayed in the “SPD SPD” column of the display. Press the M key to toggle the GPS screen between “North Up” and “Course Up”. The course direction displays a black arrow in the “North Up” screen, and displays a white arrow in the “Course Up” screen. To return to normal operation, press the m key several times until the normal screen appears. 1) When the VX-8DR GPS signal is interrupted; such as when you enter into a tunnel, the compass icon disappears from the display but maintains the position information (Longitude/Latitude) at the point where the GPS signal was lost. 2) When the built-in GPS Antenna Unit is activated, the current consumption increases 66 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 GPS OPERATION approximately 40 mA. Therefore, battery life is reduced by approximately 20 % when the built-in GPS Antenna Unit is activated. 3) You may memorize your current position as plotted by the GPS (up to ten points can be saved) via the APRS/GPS Set Mode Item 23: MY POSITION. See page xx for details. You may customize the Time Zone (Time Offset), Display Unit of the GPS screen, and GPS Datum for your own operating requirements via the APRS/GPS Set Mode. SETTING THE TIME ZONE (TIME OFFSET) Sets the time offset between your local time and UTC (Universal Time Coordinated or GMT: Greenwich Mean Time) shown on the display. 1. Press the m key several times until the GPS screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 27: TIME ZONE ZONE. 4. Press the m key briefly to enable selection of this Set Mode Item. 5. Rotate the DIAL knob to select the time offset from UTC. See illustration below to find your offset time from UTC. If UTC +0:00 “UTC +0:00” is assigned, the time is the same as UTC. 6. Press the PTT switch briefly to save the new setting and exit from the APRS/GPS Set Mode. VX-8GR OPERATING MANUAL 67 FCC ID: K6620415X20 / IC:511B-20415X20 GPS OPERATION SELECTING THE DISPLAY UNITS OF THE GPS SCREEN 1. Press the m key until the GPS screen appears. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 20: GPS UNIT UNIT. 4. Press the m key briefly to enable adjustment of this Set Mode Item. Posi5. Rotate the DIAL knob to select the preferred unit for “Position .MMM’ or ‘SS” tion” (.MMM’ ‘SS”). Speed 6. Press the b key to change the cursor to “Speed Speed”, then Km h, rotate the DIAL knob to select the preferred unit (Km Km/h mph mph, or Knot Knot). Altitude 7. Press the b key to change the cursor to “Altitude Altitude”, then rotate the DIAL knob to m or ft ft). select the preferred unit (m 8. Press the PTT switch briefly to save the new setting and exit from the APRS/GPS Set Mode. SELECTING THE MAP DATUM While most operations (including APRS® operation) will utilize the default “WGS84” database of locations, you may use a different database. 1. Press the m key until the GPS screen appears. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 17: GPS DATUM DATUM. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Rotate the DIAL knob to select the database you wish to use. Available selections are WGS-84 WGS-84, Tokyo Mean Mean, Tokyo Japan Japan, Tokyo Korea Korea, and Tokyo Okinawa Okinawa. 6. Press the PTT switch briefly to save the new setting and exit from the APRS/GPS Set Mode. Do not change the Map Datum while the GPS/APRS (described next chapter) in in operation. The position indication will be incorrect. 68 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 NOTE VX-8GR OPERATING MANUAL 69 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION The VX-8GR is equipped with a 1200/9600bps AX.25 Data Modem to enable APRS® (Automatic Packet Reporting System) operation. The Automatic Packet Reporting System (APRS®) is a software program and registered trademark of Bob Bruninga, WB4APR. PREPARATIONS any APRS® Before performing operations, set your callsign, symbol, and position (Longitude/Latitude) into the VX-8GR, and activate the AX.25 Data Modem via the APRS/ GPS Set Mode. 1. Press the m key repeatedly until “STATION LIST” appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 22: MY CALLSIGN CALLSIGN. 4. Press the m key briefly to enable Callsign programming. 5. Rotate the DIAL knob or press the appropriate keys on your keyboard to set the first letter or number in your callsign. Example 1: Rotate the DIAL knob to select any of the 37 available characters. Example 2: Press the 9 key repeatedly to toggle among the five available characters associated with that key: W X Y Z 9 W ...... 6. Press the M key to move on to the next character, if needed. 7. Repeat steps 5 and 6 as many times as necessary to complete your callsign. 8. If you make a mistake, press the B key to backspace the cursor and re-enter the correct letter/number. The callsign can consist of up to six characters. If your callsign is less than six characters, enter spaces into the remaining digits. 9. Press the M key to move on to the next position, then rotate the DIAL knob to select the SSID (Secondary Station Identifier) if desired (see next page). 10. When you have completed entering your callsign and SSID, press the m key briefly to save the new setting. 11. Rotate the DIAL knob to select Set Mode Item 24: MY SYMBOL BOL. key briefly to enable adjustment of this Set 12. Press the Mode Item. 70 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION PREPARATIONS 13. Rotate the DIAL knob to select the desired one of the three preset icons. To choose another icon, press the B key, then rotate the DIAL knob to select the desired symbol after having selected the preset icon. When you have completed selecting the icon, press the B key again. You may choose 1 of 46 different symbols. 14. Press the m key briefly to save the new setting. 15. Rotate the DIAL knob to select Set Mode Item 25: POSITION COMMENT COMMENT. 16. Press the m key briefly to enable adjustment of this Set Mode Item. 17. Rotate the DIAL knob to select the desired comment. 18. Press the m key briefly to save the new setting. 19. Rotate the DIAL knob to select Set Mode Item 23: MY POSITION POSITION. 20. Press the m key briefly to enable adjustment of this Set Mode Item. 21. If you enter your position (Longitude/Latitude) manually without using the built-in GPS receiver, perform the folGPS lowing procedures. Otherwise, select “GPS GPS” by rotating the DIAL knob and advance to the step 22. SSID LIST SSID Non -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11 -12 -13 -14 -15 DETAILS Home Station, Home Station IGate Digipeater Digipeater Digipeater HF to VHF Gateway IGate (not Home Station) Operation via Satellite Hand-held Transceiver, such as VX-8DR Maritime Mobile Mobile Operation via Internet APRS touch-tone User (and the Occasional Balloons) Portable Units, such as Laptops, Camp Sites etc. Not Used Trackers HF Operation VX-8GR OPERATING MANUAL 71 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION PREPARATIONS 22. 23. 24. 25. 26. Lat 1) Select “Lat Lat” by rotating the DIAL knob. 2) Press the M key to enable entering of your latitude using the Decimal system. 3) Use the B and M keys to navigation to each column and then use the DIAL knob to select the desired numbers in each column. Repeat for each column to complete your latitude entry. Lat 4) Move the cursor to “Lat Lat” using the B/M key and then rotate the DIAL knob one click clockLon wise to select “Lon Lon”. Enter your longitude using the same procedure as described above, then advance to the next step. Press the m key briefly to save the new setting. Rotate the DIAL knob to select Set Mode Item 3: APRS MODEM MODEM. Press the M key briefly to enable adjustment of this Set Mode Item. 1200bps Rotate the DIAL knob to select “1200bps 1200bps” (to activate the AX.25 modem). Press the PTT switch briefly to save the new setting and exit from the APRS/GPS Set Mode. You may memorize your current position as plotted by the GPS (up to ten points can be saved). See page xx for details. The VX-8GR provides many convenient functions for the APRS operation. Refer to the “APRS/GPS Set Mode” chapter beginning with page xx for details. 72 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION RECEIVING AN APRS BEACON 1. Set the “B-Band” to the APRS frequency. 144.390 MHz is generally used in North America. If you don’t know the APRS frequency of your country, ask your dealer. The AX.25 modem cannot be activated in the “A-Band”. 2. Disable the Receiver Battery Saver via the Set Mode Item 73: SAVE RX RX. When the Receiver Battery Saver is turned on, the VX-8GR can not reliably receive an APRS Beacon. 3. When receive the APRS beacon, the alert beep will emit. 4. Press the m key several times until the “STATION LIST” screen appears on the display. The “STATION LIST” screen will save up to 50 stations. And the “STATION LIST” screen sorts each station according to the received time. 5. To confirm the details of the received beacon, rotate the STATION LIST CHARACTER DIAL knob (or press the a/b keys) to select the de- DIRECTION TO THE RECEIVED STATION STATION LIST CHARACTER sired station, then press the B key. The “Received Data STATUS TEXT “FLAG” and Time”, “Distance and Direction of the station”, and other information will be displayed. When the “Status Text” is included in the Mic Encoder Station Beacon, the “ ” icon appears at the upper right corner of the display. RECEIVED DATE & TIME 6. Rotate the DIAL knob (or press the a/b keys) to scroll DISTANCE TO THE RECEIVED STATION through additional lines or pages of the received information. 7. Press the M key to display the “Raw” data of the received APRS beacon. 8. When the confirmation is finished, press the B key to return to the STATION LIST screen. When the VX8GR GPS signal is interrupted; such as when you enter into a tunnel, the display maintains the direction on the compass icon, distance to the received station and the position information (Longitude/Latitude) at the point where the GPS signal was lost. STATION LIST CHARACTER CHARACTER Emg VX-8GR OPERATING MANUAL DETAILS Mic-E: Mic Encoder Station Mic-E: Mic Encoder Station (Emergency Beacon) Position (Fixed/Moving) Station Position (Fixed/Moving) Station (Compressed Data) Weather Station Weather Station (Compressed Data) Object Station Object Station (Compressed Data) Item Station Item Station (Compressed Data) Killed Station Killed Station (Compressed Data) Status Station Other Station (Include Non-Decoding Station) 73 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION RECEIVING AN APRS BEACON Deleting a Received Beacon from the “STATION LIST” 1. Press the m key several times until the STATION LIST screen appears on the display. 2. Rotate the DIAL knob (or press the a/b keys) to select the beacon station to be deleted. DELETE? DELETE?) 3. Press the c key. The confirmation message (DELETE? will appear on the display. Press the c key once more, the selected beacon station will be deleted from the STATION LIST. APRS ALERT BEEP LIST EMERGENCY COMMENT Set MESSAGE Received x 3 times EMERGENCY COMMENT Received GROUP/BULLETIN MESSAGE Received x 12 times BEACON Received (@Filter “ON”) MESSAGE ACK Received BEACON Received (@Filter “OFF”) MESSAGE REJ Received OWN BEACON (MY POSITION) Received 74 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION APRS FILTER SETTING The APRS filter option allows you to receive only specified types of the data. 1. Press the m key several times until the STATION LIST screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 2: APRS FILTER FILTER. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Press the a/b key to select the “Filter” you wish to OFF exclude, then rotate the DIAL knob to select “OFF OFF”. OFF 6. Repeat above steps and select “OFF OFF” to any other filters you wish to exclude. 7. When you have completed your selection, press the PTT switch to save the new setting and exit to the STATION LIST screen. VX-8GR OPERATING MANUAL 75 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION TRANSMIT AN APRS BEACON To transmit your APRS Beacon, just press the d key. The VX-8GR allows you to transmit your APRS Beacon automatically and repeatedly via the APRS/GPS Set Mode. 1. Press the m key several times until the STATION LIST screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 14: BEACON TX TX. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Rotate the DIAL knob to select the desired “Auto” beacon mode. MANUAL MANUAL: Disable Automatic Transmission. AUTO AUTO: Enable Automatic Transmission. AUTO Transmits your APRS beacon in accordance with the interval determined by Set Mode Item 12: BEACON INTERVAL INTERVAL. SMART SMART: Enable Automatic Transmission. SMART Transmits your APRS beacon in accordance with the interval determined by Set Mode Item 26: SmartBeaconing SmartBeaconing. This selection does not appear unless Set Mode Item 26: SmartBeaconing is activated. See page ??? for details. 6. Press the m key briefly, then rotate the DIAL knob to select Set Mode Item 12: BEACON INTERVAL INTERVAL. 7. Press the m key briefly to enable adjustment of this Set Mode Item. 8. Rotate the DIAL knob to select the desired interval time. 9. Press the PTT switch to save the new setting and exit to the STATION LIST screen. AUTO When the APRS Beacon mode is set to “AUTO AUTO”, the “” icon will appear at the upper left corner of the display. Similarly, SMART when the APRS Beacon mode is set to “SMART SMART”, the “” icon will appear at the upper left corner of the display. 1) You may toggle the APRS Beacon mode between “MANUAL”, “AUTO”, and “SMART” by pressing the M key. 2) When the APRS frequency is busy (Squelch is opened), the VX-8GR will not transmit an APRS Beacon in manual or automatic modes. Insure that the squelch is closed. 76 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION TRANSMIT AN APRS BEACON You may store five Status Text Messages (up to the 60 characters for each memory), and you may transmit one of these Status Text Messages with the APRS Beacon. 1. Press the m key several times until the STATION LIST screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 13: BEACON STATS TXT TXT. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Rotate the DIAL knob to select the Status Text register 1 - 5) you wish to store data to. (1 6. Press the M key briefly to begin comment entry into the selected resister. 7. Rotate the DIAL knob (or press the keyboard) to select the first character of the comment. 8. Press the M key to move to the next character. 9. Repeat steps 6 and 7 to program the remainder of the comment. 10. If you make a mistake, press the B key to back-space the cursor, then re-enter the correct character. 11. You may add/delete a character to a comment using the following technique. 1) If you want to clear any previous comments, press the a/b key to select the ALL CLEAR “ALL CLEAR” then press the c key. 2) If you want to delete a previously-stored comment after the cursor, press the CLEAR a/b key to select “CLEAR CLEAR” then press the c key. INSERT 3) If you want to add a character, press the a/b key to select “INSERT INSERT” then press the c key. Note: Some transceivers cannot receive the full 60-character message. We recommend that you make the message as short as possible. 12. When you have completed your entry, press the PTT switch to save the new setting and exit to the STATION LIST screen. VX-8GR OPERATING MANUAL 77 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION TRANSMIT AN APRS BEACON DIGIPEATER PATH SETTING The VX-8GR allows you to set up to eight digipeaters for the APRS Packet Path. The VX-8GR is preset to “WIDE1-1” and “WIDE1-1, WIDE2-1” digi-path to insure that your transmitted APRS Beacon is repeated by the new-N paradigm digipeaters. We recommend that you use this setting by default. 1. Press the m key several times until the STATION LIST screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 16: DIGI PATH PATH. 4. Press the m key briefly to enable adjustment of this Set Mode Item. P1 - P8 5. Rotate the DIAL knob to select the Pass Number (P1 P8) you wish to set. 6. Press the M key briefly to begin callsign entry into the selected path. 7. Rotate the DIAL knob (or press the keyboard) to select the first character of the callsign (with SSID) of the digipeater. 8. Press the M key to move to the next character. 9. Repeats steps 7 and 8 to program the remainder of the callsign. 10. If you make a mistake, press the B key to backspace the cursor, then re-enter the correct character. 11. When you have completed your entry, press the PTT switch to save the new setting and exit to the STATION LIST screen. 78 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION RECEIVING AN APRS MESSAGE 1. Set the “B-Band” to the APRS frequency. 144.390 MHz is generally used in North America. If you don’t know the APRS frequency for your country, ask your dealer. The AX.25 modem is not activated in the “A-Band”. 2. Disable the Receiver Battery Saver from Set Mode Item 73: SAVE RX RX. When the Receiver Battery Saver is turned on, the VX-8GR cannot reliably receive APRS Messages. 3. When receive the APRS message, the alert beep will emit and white LED will blink. 4. Press the m key several times until the APRS MESSAGE screen appears on the display. The APRS MESSAGE screen stores up to 30 messages. The messages are sorted according to the time the station message is received. The latest message is stored into the first message slot (First-in, First-out format). 5. To confirm the received message, rotate the DIAL knob (or press the a/b keys) to select the desired message, then press the B key. 6. Rotate the DIAL knob (or press the a/b keys) to scroll through additional lines or pages of the received stations message. 7. Press the M key to display the receive message “Raw” data. 8. When you have finished reading your message, press the B key to return to the APRS MESSAGE screen. 1) You may change the alert beep tone via APRS/GPS Set Mode Item 8: APRS RINGER MSG. 2) You may change the blinking mode of the while LED via APRS/GPS Set Mode Item 4: APRS MSG FLASH. 3) You may work the Vibrator function via APRS/GPS Set Mode Item 6: APRS MSG VIBRAT when receive an APRS message. Delete the Received Message from the “APRS MESSAGE” Screen 1. Press the m key several times until the APRS MESSAGE screen appears on the display. 2. Rotate the DIAL knob (or press the a/b keys) to select the message to be deleted. DELETE? DELETE?) 3. Press the c key. The confirmation message (DELETE? will appear on the display. Press the c key once more and the selected message will be deleted from the APRS MESSAGE screen. VX-8GR OPERATING MANUAL 79 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION RECEIVING AN APRS MESSAGE MESSAGE GROUP SETTING The Message Group option allows you to choose to receive only specific types of message information. 1. Press the m key several times until the APRS MESSAGE screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 21: MSG GROUP GROUP. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Press the a/b key to select the “Group” you wish to G1 ALL utilize (G1 ALL, G2 CQ CQ, G3 QST QST, or G4 YAESU YAESU). 6. If you add a new message group code and/or bulletin group G5 B1 B3 code, select “G5 G5” (for message group code) or “B1 B1” ~ “B3 B3” (for bulletin group code) by rotating the DIAL knob, then press the M key. 7. Use the M and B keys to navigate to each column, then use the DIAL knob to select the desired characters/numbers in each column. Repeat for each column to complete the message (up to 9 characters) or bulletin (up to 5 characters). 8. When you have completed your selection, press the PTT switch to save the new setting and exit to the APRS MESSAGE screen. 80 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION TRANSMIT AN APRS MESSAGE 1. Press the m key several times until the APRS MESSAGE screen appears on the display. 2. Press the h key to enter the “EDIT” mode. 3. Any previously stored message may be cleared using the following procedures. 1) Press the B key ALL CLEAR 2) Press the a/b key to select the “ALL CLEAR”. 3) Press the c key. 4. Enter the callsign (with SSID) of the station you wish to contact using the B/M key pad (select the cursor) or turn the DIAL knob (select the number/letter). 5. When you have completed entering the callsign (and SSID), press the M key briefly. 6. Enter the message using the B/M key pad (select the cursor) or turn the DIAL knob (select the number/letter). Available length is up to 67 characters. You may add/ delete a message/character using the following procedure. a. If you want to add a previously stored message (determined through APRS/GPS Set Mode item 5: APRS MSG TXT TXT; see next page), press the a/b key to MSG TXT 1 MSG TXT 5 select the “MSG 1” through “MSG 5” then press the c key. b. If you want to delete the message after the cursor, press the a/b key to CLEAR select “CLEAR CLEAR” then press the c key. INSERT c. If you want to add a character, press the a/b key to select “INSERT INSERT” then press the c key. 7. When the message entry is complete, press the d key to transmit the message and return to the APRS MESSAGE screen. The transmitted message is stored into the APRS MESSAGE screen. 8. When an acknowledgment packet (“ack”) is received, the beeper will sound and “” icon will appear on the display. If an acknowledgment packet (“ack”) is not received, the APRS message is transmitted repeatedly five times, once each minute. 9. The remaining number of transmissions of the message is shown on the display. When there is no acknowledgment packet (“ack”) even if the APRS message transmits five times, the “” (period) icon (on the APRS MESTXOUT SAGE screen) or “TXOUT TXOUT” notation (on the Detailed Message screen) will appear on VX-8GR OPERATING MANUAL 81 FCC ID: K6620415X20 / IC:511B-20415X20 APRS® OPERATION TRANSMIT AN APRS MESSAGE the display, instead of the remaining number of transmissions. You may select the numbers and letters for the callsign and message with the key buttons (1 through 9, and 0) in the same way as labeling memories. STORE THE FIXED FORM MESSAGE The VX-8GR allows you to store five fixed form messages (up to 16 characters for each message). 1. Press the m key several times until the APRS MESSAGE screen appears on the display. 2. Press and hold the m key for one second to enter the APRS/GPS Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 5: APRS MSG TXT TXT. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 1 - 5) 5. Rotate the DIAL knob to select the Message register (1 you wish to store your message to. 6. Press the M key briefly to begin message entry into the selected resister. 7. Rotate the DIAL knob (or press the keyboard) to select the first character of the message. 8. Press the M key to move to the next character. 9. Repeats steps 7 and 8 to program the remainder of the message. 10. If you make a mistake, press the B key to backspace the cursor and re-enter the correct character. 11. When you have completed your message entry, press the PTT switch to save the new setting and exit to the APRS MESSAGE screen. 82 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ARTSTM (AUTOMATIC RANGE TRANSPONDER SYSTEM) The ARTSTM feature uses DCS signaling to inform both parties when you and another ARTSTM-equipped station are within communications range. This may be particularly useful during Search-and Rescue situations, where it is important to stay in contact with other members of your group. Both stations must set up their DCS codes to the same code number, then activate their ARTSTM feature using the command appropriate for their radio. Alert ringers may be activated, if desired. Whenever you push the PTT, or every 25 (or 15) seconds after ARTSTM is activated, your radio will transmit a signal which includes a (subaudible) DCS signal for about 1 second. If the other radio is in range, the beeper will sound (if enabled) and IN RNG the display will show “IN RNG” as opposed to the out of range OUTRNG display “OUTRNG OUTRNG” in which ARTSTM operation begins. Whether you talk or not, the polling every 15 or 25 seconds will continue until you de-activate ARTSTM. Every 10 minutes, moreover, you can have your radio transmit your callsign via CW, to comply with identification requirements. When ARTSTM is de-activated, DCS will also be deactivated (if you were not using it previously in non-ARTSTM operation). If you move out of range for more than one minute (four pollings), your radio will sense that no signal has been received, three beeps will sound, and the display will revert to OUTRNG “OUTRNG OUTRNG”. If you move back into range, your radio will again beep, and the display will IN RNG change back to the “IN RNG” indication. During ARTSTM operation, your operating frequency will continue to be displayed, but no changes may be made to it or other settings; you must terminate ARTSTM in order to resume normal operation. This is a safety feature designed to prevent accidental loss of contact due to channel change, etc. VX-8GR OPERATING MANUAL 83 FCC ID: K6620415X20 / IC:511B-20415X20 ARTSTM (AUTOMATIC RANGE TRANSPONDER SYSTEM) BASIC ARTSTM SETUP AND OPERATION 1. Set your radio and the other radio(s) to the same DCS code number, per the discussion on page ??. 2. Press the f key, then press the 4 key. You will observe OUTRNG the “OUTRNG OUTRNG” display on the LCD below the operating frequency. ARTSTM operation has now commenced. 3. Every 25 seconds, your radio will transmit a “polling” call to the other station. When that station responds with its own IN RNG RNG” ARTSTM polling signal, the display will change to “IN to confirm that the other station’s polling code was received in response to yours. 4. Press the 4 key to exit ARTSTM operation and resume normal functioning of the transceiver. ARTSTM won’t work if you have used the Lock feature to disable the PTT! ARTSTM POLLING TIME OPTIONS The ARTSTM feature may be programmed to poll every 25 seconds (default value) or 15 seconds. The default value provides maximum battery conservation, because the polling signal is sent out less frequently. To change the polling interval: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 4: ARTS INTERVAL INTERVAL. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired polling interval 25sec or 15sec (25sec 15sec). 5. Press the PTT switch briefly to save the new setting and exit to normal operation. 84 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 ARTSTM (AUTOMATIC RANGE TRANSPONDER SYSTEM) ARTSTM ALERT BEEP OPTIONS The ARTSTM feature allows two kinds of alert beeps (with the additional option of turning them off), to alert you to the current status of ARTSTM operation. Depending on your location and the potential annoyance associated with frequent beeps, you may choose the Beep mode which best suits your needs. The choices are: IN RANGE RANGE: The beeps are issued only when the radio first confirms that you are within range, but does not re-confirm with beeps thereafter. ALWAYS ALWAYS: Every time a polling transmission is received from the other station, the alert beeps will be heard. OFF OFF: No alert beeps will be heard; you must look at the display to confirm current ARTSTM status. To set the ARTSTM Beep mode, use the following procedure: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 3: ARTS BEEP BEEP. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired ARTS Beep mode (see above). 5. Press the PTT switch briefly to save the new setting and exit to normal operation. VX-8GR OPERATING MANUAL 85 FCC ID: K6620415X20 / IC:511B-20415X20 ARTSTM (AUTOMATIC RANGE TRANSPONDER SYSTEM) CW IDENTIFIER SETUP The ARTSTM feature includes a CW identifier, as discussed previously. Every ten minutes during ARTSTM operation, the radio can be instructed to send “DE (your callsign) K” if this feature is enabled. The callsign field may contain up to 16 characters. Here is how to program the CW Identifier: 1. Press and hold the m key for one second to enter the Set Mode. ID. 2. Rotate the DIAL knob to select Set Mode Item 16: CW ID 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON” (to activate the CW ID function). 5. Press the M key to enable programming your callsign. Press and hold the h key for two seconds to clear any previous callsign, if desired. 6. Rotate the DIAL knob or press the keyboard to set the first letter or number in your callsign. Example 1: Rotate the DIAL knob to select any of the 37 available characters. Example 2: Press the 9 key repeatedly to toggle among the five available characters associated with that key: W X Y Z 9 W ..... 7. Press the M key to move on to the next character, if needed. 8. Repeat steps 6 and 7 as many times as necessary to complete your callsign. Note that the “slant bar” (– • • – •) is among the available characters, should you be a “portable” station. 9. Press and hold the h key for two seconds to delete all data after the cursor that may have been previously stored. 10. If you make a mistake, press the B key to backspace the cursor, then re-enter the correct letter/number. 11. When you have entered your entire callsign, press the m key briefly to confirm the callsign, then press the PTT switch to save the settings and exit to normal operation. 1) You may check your work by monitoring the entered callsign. To do this, repeat steps 1 - 3 above, then press the f key. 2) You may adjust the monitoring tone (CW sidetone pitch) via Set Mode Item 18: CW PITCH. Available selections are 400 - 1000 Hz (50 Hz/step). 86 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SPECTRUM ANALYZER OPERATION The Spectrum Analyzer allows viewing operating activity on channels above or below the current operating channel in the VFO mode. The display indicates the relative signal strength on channels immediately adjacent to the current operating frequency. The Spectrum Analyzer feature can be activated only while the VX-8GR is in the “Mono” band operation. Three basic operating modes for the Spectrum Analyzer are available: 1Time: In this mode, the transceiver sweeps the current band once. 1Time CONTINUOUS CONTINUOUS: In this mode, the transceiver sweeps the current band repeatedly until the c key is pressed, or the Spectrum Analyzer is turned off. Full Time CONTINUOUS Time: This mode is activated similar to a “CONTINUOUS CONTINUOUS” mode. However, the transceiver outputs the audio of the center frequency () from a speaker when the Spectrum Analyzer is activated between 108 ~ ??? MHz. SETTING UP THE SPECTRUM ANALYZER MODE: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 84: SPECANALYZER ANALYZER. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired Spectrum Analyzer mode (see above). 5. Press the PTT switch momentarily to save the new setting and exit to normal operation. TO ACTIVATE THE SPECTRUM ANALYZER: 1. Set the radio to the VFO mode in the “Mono” band operation. 2. Press the f key, then press the 8 key to activate the Spectrum Analyzer. 3. When the Spectrum Analyzer is activated, press the a or b key to change the visible bandwidth. Available selections are ±5, ±9, ±16, ±24, and ±50 channels (default: ±16 channels). The visible bandwidth, however, depends on the selected channel step size, so match the default channel steps with the amateur band you are using. 4. To turn the Spectrum Analyzer off and operate on the center (displayed) channel, press the c key to stop the sweep, if needed, then press the f key followed by 8 key. VX-8GR OPERATING MANUAL 87 FCC ID: K6620415X20 / IC:511B-20415X20 SMART SEARCH OPERATION The Smart Search feature allows you to load frequencies automatically according to where activity is encountered by your radio. When Smart Search is engaged, the transceiver will search above and below your current frequency, storing active frequencies as it goes (without stopping on them even briefly); these frequencies are stored into a special Smart Search memory band, consisting of 31 memories (15 above the current frequency, 15 below the current frequency, plus the current frequency itself). Two basic operating modes for Smart Search are available: SINGLE: In this mode, the transceiver will sweep the current band once in each SINGLE direction starting on the current frequency. All channels where activity is present will be loaded into the Smart Search memories; whether or not all 31 memories are filled, the search will stop after one sweep in each direction. CONTINUOUS CONTINUOUS: In this mode, the transceiver will make one pass in each direction as with One-Shot searching; if all 31 channels are not filled after the first sweep, however, the radio will continue sweeping until they are all filled. The Smart Search feature can only be activated while the VX-8GR is operating in the Mono band mode. SETTING THE SMART SEARCH MODE 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 82: SMART SEARCH SEARCH. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired Smart Search mode (see above). 5. Press the PTT switch briefly to save the new setting and exit to normal operation. STORING SMART SEARCH MEMORIES 1. Set the radio to the VFO mode in the “Mono” band mode. Be sure that you have the Squelch adjusted properly (so that band noise is quieted). SMART SEARCH 2. Press and hold the M key until the “SMART SEARCH” notation will appear. 3. Press and hold the B key for one second to begin the Channel Counter. 4. As active channels are detected, you will observe the number of “loaded” channels increasing in the regular memory channel window. 5. Depending on the mode you set for Smart Search operation (“SINGLE” or “CONTINUOUS”), the Smart Search scan will eventually terminate, and the LCD will re- 88 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SMART SEARCH OPERATION CNT vert to Smart Search Memory Channel “CNT CNT.” 6. To recall the Smart Search memories, rotate the DIAL to choose from among the Smart Search memories. key. 7. To return to normal operation, press the Smart Search is a great tool when visiting a city for the first time. You don’t need to spend hours looking up repeater frequencies from a reference guidebook…just ask your VX-8GR where the action is! VX-8GR OPERATING MANUAL 89 FCC ID: K6620415X20 / IC:511B-20415X20 MESSAGE FEATURE GENERAL The VX-8GR provides a message feature, which sends a message (up to 16 characters) instead of sending a voice. 20 different messages can be programmed, any one of them can be selected and transmitted with your ID. Note The Message Feature requires that all members (1) use the Yaesu VX-8GR, VX-8DR, VX-8R, VX-3R, FTM-10R/SR or FTM-350R transceiver, (2) store the same messages into the message slots, (3) store the same member list into the member box, and (4) set the same frequency. Does not send the Message through a repeater. PROGRAMMING A MESSAGE (Requires all members set the same messages into the same message slots in the same order.) The VX-8GR has 20 message slots, including a factory-programmed message (EMERGENCY). The factory-programmed message of course can be overwritten at any time with personalized messages. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 54: MESSAGE SELECT SELECT. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired Message slot into which you wish to store a message. The LCD displays the previously stored message. 5. Press the M key briefly to enable programming of the message. 6. Press and hold in the h key for one second to clear the previously stored message, if desired. 7. Rotate the DIAL knob or press the keyboard to set the first character of the message you wish to store. Example 1: Rotate the DIAL knob to select any of the 61 available characters. Example 2: Press the 2 key repeatedly to toggle among the four available characters associated with that key: a b c A B C 2 a ..... 8. Press the M key to move on to the next character, if needed. 90 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MESSAGE FEATURE PROGRAMMING A MESSAGE 9. Repeat steps 7 and 8 above to complete the message (up to 16 characters). If you make a mistake, press the B key to move back to the incorrect character, then re-enter the correct character. 10. Press and hold in the h key for one second to delete all data after the cursor that may have been previously stored. 11. When the Message entry is complete, press the m key briefly to save the new setting. 12. If you wish to store another message, repeat steps 3 through 11 above. 13. Press the PTT switch to exit to normal operation. PROGRAMMING A MEMBER LIST (Requires all members set the same member list (includes own ID) into the same member box in the same order.) It is possible to register a maximum of 20 persons, in order to identify the sender. When you receive a message transfer, you will know who sent the message by the ID in the register. In addition, your ID can be sent to the members when you transmit any messages to them. If all the members share the register information (ID), the message sender ID will be shown on the display when receiving the message. Even if no IDs are registered, the message function can work. However, in this case, MESSAGE1 MESSAGE20 “MESSAGE1 MESSAGE1” though “MESSAGE20 MESSAGE20” will be displayed when receiving a message. We recommend that you use your call sign for the member list. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 52: MESSAGE LIST LIST. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired member box (1 ~ 20 20) into which you wish to store a member ID. The LCD will display the previously stored personal ID. 5. Press the M key briefly to enable programming of the personal ID. 6. Press and hold in the h key for two seconds to clear the previously stored personal ID, if desired. 7. Rotate the DIAL knob or press the keyboard to set the first VX-8GR OPERATING MANUAL 91 FCC ID: K6620415X20 / IC:511B-20415X20 MESSAGE FEATURE PROGRAMMING A MEMBER LIST 8. 9. 10. 11. 12. 13. character of the message you wish to store. Example 1: Rotate the DIAL knob to select any of the 61 available characters. Example 2: Press the 7 key repeatedly to toggle among the nine available characters associated with that key: p q r s P Q R S 7 p ..... Press the M key to move on to the next character, if needed. Repeat steps 7 and 8 above to complete the personal ID (up to 8 characters). If you make a mistake, press the B key to move back to the incorrect character, then re-enter the correct character. Press and hold in the h key for two seconds to delete all data after the cursor that may have been previously stored. When the personal ID entry is complete, press the m key briefly to save the new setting. If you wish to store another personal ID, repeat steps 3 through 10 above. Press the PTT switch to exit to normal operation. SET YOUR PERSONAL ID You may choose your personal ID from the member list as follows. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 53: MESSAGE REGISTER REGISTER. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 1 ~ 20 4. Rotate the DIAL knob to select the member box (1 20) where your ID is stored. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. 92 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MESSAGE FEATURE SENDING A MESSAGE The registered message can be sent to the members who are receiving on the coordination frequency. When a message is sent, the transmitter’s ID will be sent also, and the receiver can identify who sent the message. The “Personal ID” setting (described in the previous paragraph) is required for the transmitter’s ID to be shown with the received message. 1. Set the radio to the coordination frequency. 2. Press and hold the m key for one second to enter the Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 54: MESSAGE SELECT SELECT. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Rotate the DIAL knob to select the desired Message slot you wish to send. 6. Press the PTT switch to exit to normal operation. 7. Press the f key, then press the M key. This provides a “Short-cut” to Menu Item 88: SQL TYPE TYPE. MESSAGE 8. Rotate the DIAL knob until “MESSAGE MESSAGE” appears on the display; this activates the Message feature. 9. Press the PTT switch to exit from the Menu mode and activate the Message feature. When the Message feature is acMSG tivated, the “MSG MSG” notation will appear on the display. 10. Press the PTT switch again (without speaking into the microphone) to transmit the selected message on the coordination frequency. It takes approximately 6 seconds to transmit the message. VX-8GR OPERATING MANUAL 93 FCC ID: K6620415X20 / IC:511B-20415X20 MESSAGE FEATURE RECEIVING A MESSAGE 1. Set the radio to the coordination frequency. 2. Press the f key, then press the M key. This provides a “Short-cut” to Set Mode Item 88: SQL TYPE TYPE. MESSAGE 3. Rotate the DIAL knob until “MESSAGE MESSAGE” appears on the display; this activates the Message feature. 4. Press the PTT switch to exit from the Set Mode and activate the Message feature. When the Message feature is acMSG tivated, the “MSG MSG” notation will appear on the display. 5. When you receive a message: a beep sounds, the LED light blinks white, and [“Message” FROM “sending station’s ID”] scrolls on the display. 6. Press any key (except g key) to clear the received message, and wait for a new message. To disable the Message feature, repeat the above procedure, rotating the DIAL knob to OFF select “OFF OFF” in step 3 above. If you enable the CTCSS/DCS/EPCS Bell feature or CTCSS/DCS/EPCS Vibrator Operation (described previously), you can tell that you are receiving a message by the ringing “bell” sound alert or vibrating the transceiver. 94 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 EMERGENCY FEATURE EMERGENCY CHANNEL OPERATION The VX-8GR includes an “Emergency” feature, which may be useful if you have someone monitoring on the same frequency as your transceiver’s UHF “Home” channel. See page ?? for details on setting the Home channel. The “Emergency” feature is activated by pressing and holding in the h key for one second. When this is done, (A) the radio is placed on the UHF amateur band Home channel, (B) it emits a loud “Alarm” sound (the volume is controlled by rotating the DIAL knob while pressing and holding the g key), (C) it flashes the LED light in white, (D) if you press the PTT switch, you will disable the Emergency feature temporarily. You can then transmit on the UHF Home channel, and (E) two seconds after the PTT switch release, the Emergency feature will resume. To disable the “Emergency” feature, press and hold the h key for one second or turn the radio Off by pressing and holding in the p(PWR) switch for one second. Use this feature if you are out for a walk and want a quick way of alerting a family member to a dangerous situation. The alarm sound may discourage an attacker and allow you to escape. 1) Be sure to arrange with a friend or family member to be monitoring on the same frequency, as there will be no identification sent via the Emergency alarm sound. And do not transmit the alarm tone except in a true emergency! 2) The LED light may be changed to another function via Set Mode Item 29: EMERGENCY SELECT; see page xx. VX-8GR OPERATING MANUAL 95 FCC ID: K6620415X20 / IC:511B-20415X20 EMERGENCY FEATURE EMERGENCY AUTOMATIC ID (EAI) FEATURE The Emergency Automatic ID (EAI) feature can be used to aid in searching for persons who are incapacitated in disasters like earthquakes, especially search-and-rescue personnel who may have become injured in a debris field. When using the EAI feature, a searcher transmits a unique command (CTCSS tone pair), which will automatically cause the injured party’s radio to transmit, so others may perform direction-finding and effect a rescue. The incapacitated party may not be able to speak or even press the PTT switch. The callsign of the incapacitated person will also be transmitted, to assist the rescue team. If an emergency group is working in a dangerous area, all members should engage the EAI feature on their transceiver, so that others can assist a fallen team member, if necessary. The Emergency Automatic ID (EAI) Feature has two operating modes: (1) Interval mode and (2) Continuous mode. In the Interval mode (when the VX-8GR receives the CTCSS tone pair), the radio will automatically transmit a brief (0.5 second) beep tone every 2.5 seconds until the EAI timer expiration. In the continuous mode, the radio will automatically transmit continuously (with maximum microphone gain), until the EAI timer expiration. The EIA is activated when the CTCSS tone pair stored in the Receiving Pager Code Memory (configured via Set Mode Item 62: PAGE CODE-RX CODE-RX) is received for 5 seconds on the EAI frequency, which is stored in Memory Channel “EAI EAI”. It is NOT necessary for the incapacitated person to press the PTT switch. If your call sign is stored in the radio and the CW identifier is enabled via Set Mode Item ID, the radio will transmit your callsign on the air when the EAI feature is first 16: CW ID activated by the remote page, and every 10 minutes thereafter. The “callsign” ID can be changed to any desired sequence of characters, such as a name. After sending the callsign or name, the radio will repeatedly transmit three tones for a user-defined period of time (between 1 and 30 minutes). The callsign or name will be transmitted every 10 minutes. The Emergency Automatic ID (EAI) Feature requires that you (1) store the CTCSS Tone Pair into the Receiving Pager Memory (see page xx for procedure), and (2) store the EAI desired UHF coordination frequency into Memory Channel “EAI EAI” (see page 47 for procedure). 96 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 EMERGENCY FEATURE EMERGENCY AUTOMATIC ID (EAI) FEATURE SELECTING THE EAI MODE AND ITS TRANSMIT TIME 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 28: EAI TIME TIME. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired EAI mode (InINT CON terval EAI “INT INT” or Continuous EAI “CON CON”) and transmit 10 1-10 20, 30 30, 40 40, and 50 minutes). time (1 10, 15 15, 20 5. Press the PTT switch briefly to save the new setting and exit to normal operation. ACTIVATING THE EAI FEATURE 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 27: EAI EAI. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON” (thus activating the EAI feature). 5. Press the PTT switch briefly to save the new setting and exit to normal operation (with EAI feature “ON”). EAI When the EAI feature is activated, the “EAI EAI” icon and the Band Number (or memory channel number) will appear alternately in the Memory Channel Number Display Slot of the display. To disable the EAI feature, just repeat the above procedure, rotating the DIAL knob to OFF select “OFF OFF” in step “4” above. The VX-8GR will ignore the EAI feature when (1) the squelch is open, (2) there is an incoming signal on the operating frequency, (3) the operating frequency is the same as the frequency which is stored in the Memory Channel “EAI,” or (4) a VHF frequency is stored in Memory Channel “EAI”. VX-8GR OPERATING MANUAL 97 FCC ID: K6620415X20 / IC:511B-20415X20 EMERGENCY FEATURE EMERGENCY AUTOMATIC ID (EAI) FEATURE TO LOCATE AN UNRESPONSIVE OPERATOR USING THE EAI FEATURE EAI 1. Recall the Memory Channel “EAI EAI” (must be the same as the searched person’s radio), which is found in the next to the last “regular” memory channel. 2. Set the CTCSS tone pair to the same CTCSS tone pair stored in the Receiving Pager Code Memory of the missing person’s radio. 1) Press the f key, then press the 2 key. This provides a “Short-cut” to Set Mode Item 63: PAGE CODETX TX. 2) Rotate the DIAL knob to select the first tone. 3) Press the M key. 4) Rotate the DIAL knob to select the second tone. 5) Press the 2 key to save the new setting and exit from setting mode. 3. Press and hold in the PTT switch for five seconds. If the EAI signal is received by a VX-8GR transceiver programmed with matching EAI CTCSS tones the EAI feature will activate. The lost operator’s radio will beep loudly, and its transmitter will respond repeatedly. You may now begin direction-finding efforts. 4. The ATT (Front End Attenuator) is often useful in locating the missing person’s radio, as peaks in weaker signals are ATT 1 more easily observed. You may select the ATT level “ATT ATT 2 (50 dB),” and “ATT ATT OFF (10 dB),” “ATT OFF” by pressing the B key to reduce the signal. 5. Press the c key to exit to normal operation. 98 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 INTERNET CONNECTION FEATURE GENERAL The VX-8GR can be used to access a “node” (repeater or base station) which is tied into the Vertex Standard WIRES™ (Wide-Coverage Internet Repeater Enhancement System) network, operating in the “SRG” (Sister Radio Group) mode. Details may be found at the WIRES-II Web site: http://www.vxstd.com/en/wiresinfo-en/. This feature may also be used to access other systems, as described below. SRG (“SISTER RADIO GROUP”) MODE 1. Press the d key to activate the Internet Connection feature. The “ ” icon will appear in the lower left corner of the display. 2. Rotate the DIAL knob, while pressing and holding in the DTMF 0 DTMF d key, to select the access number (“DTMF 0” - “DTMF DTMF D DTMF 9”, “DTMF DTMF A DTMF B DTMF C A”, “DTMF B”, “DTMF C”, “DTMF D”, “DTMF DTMF # ”, “DTMF #”) corresponding to the WIRES™ repeater to which you wish to establish an Internet link (ask your repeater owner/operator if you don’t know the access numbers in the network). Now press the PTT switch to exit from the selection mode. 3. With the Internet Connection feature activated (as in step 1 above), the VX-8GR will generate a brief (0.1 second) DTMF tone according to your selection in step 2. This DTMF tone is sent at the beginning of every transmission to establish or maintain the link to the remote WIRES™ repeater operating in the SRG mode. 4. To disable the Internet Connection feature, press the d key again (The “ ” icon disappear from the display. If other users report that you always have a DTMF “beep” at the beginning of each transmission, and you are not operating in conjunction with Internet access, disable this function via step 4 above. VX-8GR OPERATING MANUAL 99 FCC ID: K6620415X20 / IC:511B-20415X20 INTERNET CONNECTION FEATURE FRG (“FRIENDLY RADIO GROUP”) MODE You may access other Internet Link Systems (including WIRES™ in the FRG mode) that use a DTMF string for access. PROGRAMMING THE FRG CODE Load the DTMF tones which you wish to use for Internet-link access into an Internet Memory Register. For purposes of this example, we will use “#1101D” as the access code of the W6DXC node. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 40: INTERNET SELECT SELECT. 3. Press the key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the DTMF Memory register 1” - “64 64 (“1 64”) into which you wish to store the access code. 5. If you wish to attach an alpha/numeric name “Tag” to the Internet Memory, proceed to the next step; otherwise press the B key then skip to step 13. 6. Press the M key briefly to enable programming of the name tag. 7. Rotate the DIAL knob to select the first digit of the desired label. 8. Press the M key to move to the next character. 9. If you make a mistake, press the B key to back-space the cursor, then re-enter the correct letter, number, or symbol. 10. Repeat steps 7 through 9 to program the remaining letters, numbers, or symbols of the desired label. Eight characters may be used in the creation of a label. 11. When you have programmed a label that is less than 8 characters, press the M key twice to confirm the label and enable storing the access code; otherwise, just program the 8 character label and press the M key one time. #”. 12. Rotate the DIAL knob to select “# 13. Press the M key briefly to accept the first digit and move to the second digit of the DTMF string. 14. If you make a mistake, press the B key to backspace the cursor, then re-enter the correct letter or number. 15. Repeat steps 12 through 14 until you have completed the access code (“#1101D”). 100 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 INTERNET CONNECTION FEATURE FRG (“FRIENDLY RADIO GROUP”) MODE 16. When you have stored an access code that is less than 8 digits, press the M key twice to confirm the code and enable storing the access code; otherwise, just enter the 8 digits and press the M key one time. 17. Repeat steps 4 through 16 to store other access codes, if so desired. 18. Press the PTT switch to save the settings and exit to normal operation. OPERATION (ACCESSING AN FRG NODE) 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 39 39. 3. Press the m key briefly to enable adjustment of this Set Mode Item. FRG 4. Rotate the DIAL knob to set this Set Mode Item to “FRG FRG” (thus activating the “Other Internet Link System” mode). 5. Press the PTT switch to save the new settings. 6. Press the d key briefly to activate the Internet Connection feature. The “ ” icon will appear in the lower left of the display. 7. Rotate the DIAL knob while pressing the d key to select 1” - “64 64 the Internet Memory register number (“1 64”) corresponding to the Internet link repeater to which you wish to establish an Internet link, then press the PTT switch briefly to lock in the selected access number. 8. Once the Internet Connection feature is activated as in step 7 above, you may press the d key, while you are transmitting, to send out the selected DTMF string (to establish the link to the desired Internet-link node). SRG 9. To return to the WIRES™ SRG mode, repeat steps 1 - 5 above, selecting “SRG SRG” in step 4. VX-8GR OPERATING MANUAL 101 FCC ID: K6620415X20 / IC:511B-20415X20 DTMF OPERATION The VX-8GR’s keypad allows easy DTMF dialing for Autopatch, repeater control, or Internet-link access purposes. Besides numerical digits [0] through [9], the keypad includes the [] and [#] digits, plus the [A], [B], [C], and [D] tones often used for repeater control. MANUAL DTMF TONE GENERATION You can generate DTMF tones during transmission manually. 1. Press the PTT switch to begin transmission. 2. While transmitting, press the desired numbers on the keypad. 3. When you have sent all the digits desired, release the PTT key. DTMF AUTODIALER Nine DTMF Autodial memories are provided, allowing you to store telephone numbers for autopatch use. You can also store short autopatch or Internet-link access code streams to avoid having to send them manually. Here is the DTMF Autodial storage procedure: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 25: DTMF SELECT SELECT. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the DTMF Memory register 1 - 10 (1 10) into which you wish to store this DTMF string. 5. Press the M key briefly to begin DTMF Memory entry into the selected register. 6. Press and hold in the h key for two seconds to clear the previously-stored data, if desired. 7. Rotate the DIAL knob to select the first digit of the DTMF string. Selectable entries are 0 - 9 , A - D, , and #. You –” to store a “Pause”, if needed. may select “– 8. Press the M key to move to the next character. 9. Repeats steps 7 and 8 to program the remaining the DTMF string. 10. Press and hold in the h key for two seconds to delete the previously-stored data after the cursor. 11. If you make a mistake, press the B key to back-space the cursor, re-enter the correct number. 12. Press the PTT switch briefly to save the new setting and exit to normal operation. To store other numbers, repeat this process, using a different DTMF memory register. 102 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 DTMF OPERATION You may check your work by monitoring the entered DTMF string. To do this, repeat steps 1 - 4 above, then press the f key. To send a telephone number: 1. Press the f key, then press the 3 key. This provides a AUTO “Short-cut” to Set Mode Item 24: DTMF MANUAL MANUAL/AUTO AUTO. AUTO 2. Rotate the DIAL knob to select “AUTO AUTO” (to activate the DTMF Autodialer function). 3. Press the PTT switch to exit to normal operation and activate the DTMF Autodialer function (the “ ” icon will appear). 4. In the Autodialer function mode, first press the PTT key, then press the numerical key (1 through 9, and 0: representing “10”) corresponding to the DTMF memory string you wish to send. Once the string begins, you may release the PTT key, as the transmitter will be held “on the air” until the DTMF string is completed. To disable the DTMF Autodialer, just repeat the above procedure, rotating the DIAL knob MANUAL to select “MANUAL MANUAL” in step “2” above. 1) You can change the DTMF Autodialer sending speed, using Set Mode Item 26: DTMF SPEED, see page xx for details. 2) You can also set a longer delay between the time your transmitter is keyed and the first DTMF digit is sent, using Set Mode Item 23: DTMF DELAY, see page xx for details. VX-8GR OPERATING MANUAL 103 FCC ID: K6620415X20 / IC:511B-20415X20 CW LEARNING FEATURE The VX-8GR provides a CW learning feature, which sends the designated Morse Code via the sidetone (heard in the speaker) to help your CW learning. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 17: CW LEARNING LEARNING. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the Training mode (displayed in fine print at the upper edge of the LCD): ALPHA ALPHA: Sends the Alphabet characters ALPHA AUTO AUTO: Sends the Alphabet characters (move to next character automatically) NUMBER NUMBER: Sends the Numeric characters NUMBER AUTO AUTO: Sends the Numeric characters (move to next character automatically) SYMBL SYMBL: Sends the Symbol characters SYMBL AUTO AUTO: Sends the Symbol characters (move to next character automatically) CHR 5. Press the b key to change the cursor to “CHR CHR”, then rotate the DIAL knob to select the CW code which you want to learn. SPED 6. Press the b key to change the cursor to “SPED SPED”, then rotate the DIAL knob to select the Morse speed. You may CPM (characselect the units of the code speed in either “CPM WPM (Words per minute)” by using ters per minute)” or “WPM FORM the DIAL knob from Set Item “FORM FORM”. REPT 7. Press the b key to change the cursor to “REPT REPT”, then rotate the DIAL knob to select the sending repetition (1 9). PTCH 8. Press the b key to change the cursor to “PTCH PTCH”, then rotate the DIAL knob to adjust the CW sidetone pitch (400 - 1000 Hz, 50 Hz/step). LED 9. Press the b key to change the cursor to “LED LED”, then rotate the DIAL knob to switch the flashing of the (white) LED light “on” and “off”. 10. Press the f key to begin generating the selected code characters the designated number of times (Only the speaker CW sidetone is heard, the radio does not transmit). 11. You may adjust the CW sidetone audio level by rotating the DIAL knob while pressing and holding the g key. AUTO 12. If one of the “AUTO AUTO” modes is not selected in step 4 above, press the f key to send CHR again, or select another code by rotating the DIAL knob from “CHR CHR” item and press 104 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 CW LEARNING FEATURE the f key to begin generation. 13. To stop CW generation, press the f key again. 14. To disable CW learning feature, press the PTT switch. The “CPM” selection is based on the international “PARIS” standard, which stipulates five characters per word. VX-8GR OPERATING MANUAL 105 FCC ID: K6620415X20 / IC:511B-20415X20 CW TRAINING FEATURE The VX-8GR provides another CW learning feature; call it a CW Training feature, which sends random Morse Code via the sidetone (heard in the speaker), so you can improve your CW proficiency. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 19: CW TRAINING TRAINING. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the Training mode (displayed in fine print at the upper edge of the LCD): ALPHA 5CHR 5CHR: Sends five Alphabet characters only ALPHA REPT REPT: Sends Alphabet characters only (Repeatedly) NUMBER 5CHR 5CHR: Sends five Numeric characters only NUMBER REPT REPT: Sends Numeric characters only (Repeatedly) MIX 5CHR 5CHR: Sends five Alphabet, Numeric, “?”, and “/” characters (Mixed) MIX REPT REPT: Sends Alphabet, Numeric, “?”, and “/” characters (Mixed, Continuously in groups of five) SPED 5. Press the b key to change the cursor to “SPED SPED”, then rotate the DIAL knob to select the Morse speed. You may CPM (characselect the units of the code speed between “CPM WPM (Words per minute)” by the ters per minute)” and “WPM FORM DIAL knob from Set Item “FORM FORM”. PTCH 6. Press the b key to change the cursor to “PTCH PTCH”, then rotate the DIAL knob to adjust the CW sidetone pitch (400 - 1000 Hz, 50 Hz/step). LED 7. Press the b key to change the cursor to “LED LED”, then rotate the DIAL knob to switch the flashing of the (white) LED light “on” and “off”. MODE 8. Press the a/b key to change the cursor to “MODE MODE. 9. Press the f key to begin generation of the code characters (CW sidetone only, the radio does not transmit); the generCHR ated characters will appear at the right of the “CHR CHR” item. 10. You may adjust the CW sidetone audio level by rotating the DIAL knob while pressing and holding the g key. 5CHR 11. If one of the “5CHR 5CHR” modes is selected in step 4 above, press the f key to send another code group. 12. To stop CW generation, press the f key again. 13. To disable CW training feature, press the PTT switch. The “CPM” selection is based on the international “PARIS” standard, which stipulates five characters per word. 106 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SENSOR MODE The VX-8GR always displays the “Battery Voltage” and “Current Time” while the VX-8GR is operating in the “Mono” band mode with the Large characters. You may change the “Battery Voltage” display to the “Temperature” display which indicates the current temperature inside the transceiver’s case. To change the display from the “Battery Voltage” to the “Temperature”: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 78: SENSOR DISPLAY DISPLAY. 3. Press the m key briefly to enable adjustment of this Set Mode Item. TEMP 4. Rotate the DIAL knob to select “TEMP TEMP”. 5. Press the PTT switch briefly to exit to normal operation and display the sensor information on the display. To return to the “Battery Voltage” display, just repeat the above procedure, rotating the DC DIAL knob to select “DC DC” in step “4” above. 1) When select “OFF” in step “4” above, the VX-8GR displays only the “Current Time” while the VX-8GR is operating in the “Mono” band mode with the Large characters. 2) You may monitor the “Battery Voltage” using Set Mode Item 20: DC VOLTAGE, and the “Temperature” using Set Mode Item 79: SENSOR INFO . CLOCK SET The VX-8GR has a 24-hour clock with a calendar which covers all dates from January 1, 2000 through December 31, 2099 (accuracy: ±30 sec/month). To set the clock: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 90: TIME SET SET. 3. Press the m key briefly to enable adjustment of this Menu Item. 4. Rotate the DIAL knob to select the “year” setting. 5. Press the M key briefly, then rotate the DIAL knob to select the “month” setting. 6. Repeat the above step to set the “day,” “day of the week,” “hour,” and “minute” selections. 7. Press the M key briefly, then rotate the DIAL knob to set SIG –– SIG “Timer Signal” On (SIG SIG) or Off (–– ––). In the “SIG SIG” mode, a VX-8GR OPERATING MANUAL 107 FCC ID: K6620415X20 / IC:511B-20415X20 SENSOR MODE double-beep will be emitted from the speaker at the top of each hour, as long as the transceiver is turned on. 8. Press the M key briefly, press the c key to start the clock from “00” seconds. 9. When you have finished the time setup, press the PTT switch to save the new setting and return to normal operation. The VX-8GR has a rechargeable Li-Ion battery cell used just for the clock. Therefore, the VX-8GR can maintain its clock data for approximately two months without using the main battery pack or external DC power. 108 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING PASSWORD The VX-8GR provides a password feature which can minimize the chance that your transceiver could be used by an unauthorized party. When the password feature is activated, the radio will ask for the four digit password to be entered when the radio is first turned on. You must enter the four digit password from the keypad. If the wrong password is entered, the microprocessor will shut down the radio automatically. To enter and activate the password use the following procedure: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 64: PASSWORD PASSWORD. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Press the M key to enable programming the password. 5. Rotate the DIAL knob to select the first digit of the 0 - 9 , A , B, C desired number/letter (0 C, D, , and #). 6. Press the M key to move to the next digit. 7. Repeat steps 5 and 6 to program the remaining numbers/letters of the desired password. 8. If you make a mistake, press the B key to move back to the previous digit, then select the correct number/letter. 9. When you have finished entering the password, press ON the M key and rotate the DIAL knob to select “ON ON” (to activate the password feature). 10. Press the PTT switch to save the new setting and exit to normal operation. If you wish to disable the Password feature, repeat steps 1 - 3 above. Rotate the DIAL OFF OFF”, then press the PTT switch. knob to select “OFF 1) We recommend that you write down the password number, and keep it in a safe place where you can easily find if you forget your password. 2) If you forget the password number, you may turn on the transceiver by performing the “Microprocessor Resetting” procedure (see page xx). However, the VX-8GR will clear the password, as well as all memories, and will restore all other settings to factory defaults. VX-8GR OPERATING MANUAL 109 FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING PROGRAMMING THE KEY The Internet Key is the factory default (“primary” press key) function of the d key. However, you may change the “primary” (press key) function of the d key to another function via the Menu mode. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 38: INTERNET KEY KEY. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired function: INTERNET INTERNET: Activates/Disables the internet feature. INTERNET SELECT SELECT: Recalls the Internet Access Number (SRG) or Access String (FRG). Select the SRG number or FRG string via Menu Item 39: INTERNET MODE MODE. SET MODE MODE: A short cut path to recall one of the Menu Items. See box below for programming. 5. When you have made your selection, press the PTT switch briefly to save the new setting and exit to normal operation. When “INTERNET SELECT” or “SET MODE” is assigned to the d key, the INTERNET function may be activated/disabled via Set Mode Item 36: INTERNET. ASSIGN THE SET MODE ITEM TO THE KEY SET MODE 1. Change (“primary” press key) function of the key to “SET MODE”, using Set Mode Item 38: INTERNET KEY KEY, as descried above. key for one second to enter the Set Mode again. 2. Press and hold in the 3. Rotate the DIAL knob to select the Set Mode Item which you wish to assign to the key as a short-cut. key for one second to assign the Set Mode Item to 4. Press and hold in the MY KEY key. “MY KEY” will appear on the display, to confirm that the comthe mand was executed. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. Now, briefly pressing of the key will immediately recall the selected Menu key again to exit to normal operation. Item. You must press the 110 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING ATT (FRONT END ATTENUATOR) The attenuator will reduce all signals (and noise) by 10 dB, and it may be used to make reception more pleasant under extremely noisy conditions. 1. Set a band (“A-Band” or “B-Band”) on which you wish to activate the “attenuator” to the “Operating” Band (indicated in large character). 2. Press and hold the m key for one second to enter the Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 1: ANTENNA ATT ATT. 4. Press the m key briefly to enable adjustment of this Set Mode Item. OFF 5. Rotate the DIAL knob to change the setting from “OFF OFF” to ON “ON ON”. 6. When you have made your selection, press the PTT key to save the new setting and exit to normal operation. 7. If you wish to disable the attenuator, just repeat the above procedure, rotate the DIAL OFF knob to select “OFF OFF” in step “5” above. 1) When the attenuator is activated, the “ ” icon will appear on the display. 2) The attenuator can be set independently on each operating band of the “A-Band” and “B-Band”. VX-8GR OPERATING MANUAL 111 FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING RECEIVE BATTERY SAVER SETUP An important feature of the VX-8GR is its Receive Battery Saver, which “puts the radio to sleep” for a time interval, periodically “waking it up” to check for activity. If somebody is talking on the channel, the VX-8GR will remain in the “active” mode, then resume its “sleep” cycles. This feature significantly reduces quiescent battery drain, and you may change the amount of “sleep” time between activity checks using the Menu System: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 73: SAVE RX RX. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired “sleep” duration. The selections available are 0.2sec - 0.9sec (0.1sec/ step), 1.0sec - 9.5sec (0.5sec/step), 10.0sec - 60.0sec (5sec/step), or OFF OFF. The default value is 0.2sec 0.2sec. 5. When you have made your selection, press the PTT switch to save the new setting and exit to normal operation. When you are operating on Packet, switch the Receive Battery Saver OFF, as the sleep cycle may “collide” with the beginning of an incoming Packet transmission, causing your TNC not to receive the full data burst. TX BATTERY SAVER The VX-8GR also includes a useful Transmit Battery Saver, which will automatically lower the power output level when the last signal received was very strong. For example, when you are in the immediate vicinity of a repeater station, there generally is no reason to use the full 5 Watts of power output in order to achieve full-quieting access to the repeater. With the Transmit Battery Saver, the automatic selection of Low Power operation conserves battery drain significantly. To activate the Transmit Battery Saver: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 74: SAVE TX TX. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to set this Set Mode Item to “ON ON” (thus activating the Transmit Battery Saver). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. To disable the Transmit Battery Saver, just repeat the above proOFF cedure, rotating the DIAL knob to select “OFF OFF” in step 4 above. 112 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING DISABLING THE BUSY INDICATOR Further battery conservation may be accomplished by disabling the BUSY indicator while receiving a signal. Use the following procedure: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 14: BUSY LED LED. 3. Press the m key briefly to enable adjustment of this Set Mode Item. OFF 4. Rotate the DIAL knob to set this Set Mode Item to “OFF OFF” (thus disabling the BUSY lamp). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. To enable the BUSY indicator, just repeat the above procedure, rotating the DIAL knob to ON select “ON ON” in step 4 above. AUTOMATIC POWER-OFF (APO) FEATURE The APO feature helps conserve battery life by automatically turning the radio off after a user-defined period of time within which there has been no dial or key activity. The available selections for the time before power-off are 0.5 - 12.0 hour, as well as APO Off. The default condition for the APO is OFF, and here is the procedure for activating it: 1. Press and hold the m key for one second to enter the Set Mode. APO. 2. Rotate the DIAL knob to select Set Mode Item 2: APO 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired time period after which the radio will automatically shut down. 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. When the APO is activated, the “ ” icon will appear at the center bottom on the LCD. If there is no action by you within the time interval programmed, the microprocessor will shut down the radio automatically. Just press and hold in the p(PWR) switch for 2 seconds to turn the transceiver back on after an APO shutdown, as usual. To disable the APO, just repeat the above procedure, rotating the DIAL knob to select OFF “OFF OFF” in step 4 above. VX-8GR OPERATING MANUAL 113 FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING TRANSMITTER TIME-OUT TIMER (TOT) The TOT feature provides a safety switch which limits transmission to a pre-programmed value. This will promote battery conservation by not allowing you to make excessively long transmissions, and in the event of a stuck PTT switch (perhaps if the radio or a Speaker/Mic is wedged between car seats) it can prevent interference to other users as well as battery depletion. As configured at the factory the TOT feature is set to OFF, and here is the procedure for activating it: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 94: TOT TOT. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to set the Time-Out Timer to the desired “Maximum TX” time. The available selections are 0.5 - 10.0 minutes (0.5 minute/step). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. To disable the Time-Out Timer, just repeat the above procedure, rotating the DIAL knob to OFF select “OFF OFF” in step 4 above. 1) When your transmission time is within 10 seconds of the Time-Out Timer expiration, an Alert bell will provide an audible warning from the speaker. 2) Since brief transmissions are the mark of a good operator, try setting up your radio’s TOT feature for a maximum transmission time of 1 minute. This will significantly improve battery life, too! 114 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING ON/OFF PRESET TIMER The VX-8GR includes the capability to turn itself on/off at preset time. If you use these features, you must first set the VX-8GR’s clock, as described previously (page xx). ON TIMER 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 59: ON TIMER TIMER. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to set the “hour” at which you want the radio to switch on. 5. Press the M key, then rotate the DIAL knob to set the “minute” at which you want the radio to switch on. 6. Press the M key, then rotate the DIAL knob to set this ON Menu Item to “ON ON”. 7. When you have made your selections, press the PTT switch to save the new setting and exit to normal operation. To disable the ON Timer, just repeat the above procedure, rotating the DIAL knob to OFF select “OFF OFF” in step 6 above. OFF TIMER 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 58: OFF TIMER TIMER. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to set the “hour” at which you want the radio to switch off. 5. Press the M key, then rotate the DIAL knob to set the “minute” at which you want the radio to switch off. 6. Press the M key, then rotate the DIAL knob to set this ON Menu Item to “ON ON”. 7. When you have made your selections, press the PTT switch to save the new setting and exit to normal operation. To disable the OFF Timer, just repeat the above procedure, rotating the DIAL knob to OFF select “OFF OFF” in step 6 above. VX-8GR OPERATING MANUAL 115 FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING BUSY CHANNEL LOCK-OUT (BCLO) The BCLO feature prevents the radio’s transmitter from being activated if a signal strong enough to break through the “noise” squelch is present. On a frequency where stations using different CTCSS or DCS codes may be active, BCLO prevents you from disrupting their communications accidentally (because your radio may be muted by its own Tone Decoder). The default setting for the BCLO is OFF, and here is how to change that setting: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 7: BCLO BCLO. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to set this Set Mode Item to “ON ON” (thus activating the BCLO feature). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. To disable the BCLO feature, just repeat the above procedure, OFF rotating the DIAL knob to select “OFF OFF” in step 4 above. CHANGING THE TX DEVIATION LEVEL In many areas of the world, channel congestion has required that operating channels be closely spaced. In such operating environments, it is often required that operators use reduced deviation levels, to reduce the potential for interference to users on adjacent channels. The VX-8GR includes a simple method of accomplishing this: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 32: HALF DEVIATION DEVIATION. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to change this Set Mode Item to “ON ON”. In this configuration (HALF DEVIATION active), the transmitter’s deviation will be approximately ±2.5 kHz. 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. The “normal” setting for the deviation (when this Set Mode Item is set to “OFF”) is ±5 kHz. 116 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING CHANGING THE MICROPHONE GAIN At the factory, a microphone gain has been programmed that should be satisfactory for the internal microphone. If you use the radio under the noisy environment, you may wish to set a different microphone gain level. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 55: MIC GAIN GAIN. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired microphone level. The available selections are LEVEL 1 - LEVEL 9 (factory default: LEVEL 5 5). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. S-AND TX POWER METER SYMBOLS The VX-8GR has four types of S- (Signal Strength) and TX Power Meter symbol formats available. You may change the default setting to any of the available symbols. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 83: S-METER SYMBOL SYMBOL. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired meter symbol type. , or 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. VX-8GR OPERATING MANUAL 117 FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING DISPLAY CONTRAST The LCD’s contrast may be adjusted for best viewing in sunlight or darkness allowing for best readability using the Set Mode Item. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 43: LCD CONTRAST CONTRAST. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to adjust the contrast. As you make the adjustment, you will be able to see the effects of your changes. The available selections are LEVEL 12 - LEVEL 32 (factory default: LEVEL 24 24). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. DISPLAY DIMMER The LCD and keypad illumination may be adjusted using the Set Mode Item, as well. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 44: LCD DIMMER DIMMER. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to adjust the display illumination for a comfortable brightness level. As you make the adjustment, you will be able to see the effects of your changes. The available selections are LEVEL 1 - LEVEL 4 (factory default: LEVEL 4 4). 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. 118 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING MY BANDS OPERATION The “My Bands” feature allows you to select several operating bands, and make only those bands available for selection via the B key. For example, if you do not need the reception of the VHF and UHF TV bands, you may skip (omit) these bands from the band selection loop. My Bands Setup 1. Set the VX-8GR to the VFO mode. 2. Press and hold the m key for one second to enter the Set Mode. 3. Rotate the DIAL knob to select Set Mode Item 96: VFO SKIP SKIP. 4. Press the m key briefly to enable adjustment of this Set Mode Item. 5. Rotate the DIAL knob to choose a band number (see chart below) you wish to omit (skip) form the band selection loop. 6. Press the M key, then rotate the DIAL knob to select ON “ON ON” and omit (skip) the band from the band selection loop. ON Note: The band presently in use cannot be turned “ON ON”. 7. Press the M key again. 8. Repeat steps 5 through 7 above to select as many bands as you like. 9. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. To re-institute a band into the band selection loop, repeat the above procedure, rotating the OFF DIAL knob to select “OFF OFF” in step 6. BAND NUMBER BAND NUMBER CHART FREQUENCY RANGE OPERATING BAND “VFO-A” “VFO-B” AIR Band 108-137 MHz 108-137 MHz VHF HAM Band 137-174 MHz 137-174 MHz VHF Band 174-222 MHz 174-222 MHz INFO 1 Band 222-420 MHz 222-420 MHz UHF HAM Band 420-470 MHz 420-470 MHz UHF Band 470-774 MHz 470-580 MHz INFO 2 Band 774-999.99 MHz – USA Version: Cellular Blocked VX-8GR OPERATING MANUAL 119 FCC ID: K6620415X20 / IC:511B-20415X20 MISCELLANEOUS SETTING CHANGING THE STATUS OF THE g KEY By factory default, the g key keeps the status while pressing and holding the g key down. You may change the status of the g key to keep the status for approximately three seconds after pressing the g key, after which time it reverts back to its previous status. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 99: VOLUME MODE MODE. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired mode. NORMAL NORMAL: The g key keeps the status while pressing and holding the g key down. AUTO BACK BACK: The g key keeps its status for approximately three seconds after pressing the g key. 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. 120 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 RESET PROCEDURES In some instances of erratic or unpredictable operation, the cause may be corruption of data in the microprocessor (due to static electricity, etc.). If this happens, resetting of the microprocessor may restore normal operation. Note that all memories will be erased if you do a complete microprocessor reset, as described below. MICROPROCESSOR RESETTING To clear all memories and other settings to factory defaults: 1. Turn the radio off. 2. Press and hold in the B, h, and d keys while turning the radio on. 3. Press the f key briefly to reset all settings to their factory defaults (press any other key to cancel the Reset procedure). SET MODE RESETTING To reset the Set Mode (includes the APRS®/GPS Set Mode) settings to their factory defaults: 1. Turn the radio off. 2. Press and hold in the B and c keys while turning the radio on. 3. Press the f key briefly to reset the Set Mode Item settings to their factory defaults (press any other key to cancel the Reset procedure). :Except the following Set Mode Items. Set Mode 6: BANK NAME, 15: CLOCK SHIFT, 16: CW ID, 21: DCS CODE, 22: DCS INVERSION, 25: DTMF SELECT, 29: EMERGENCY SELECT, 32: HALF DEVIATION, 37: INTERNET CODE, 40: INTERNET SELECT, 47: MEMORY FIRST STEP, 48: MEMORY NAME, 50: MEMORY SKIP, 54: MESSAGE SELECT, 62: PAGER CODE-RX, 63: PAGER CODE-TX, 70: RPT SHIFT, 71: RPT SHIFT FREQ, 88: SQL TYPE, 91: TONE FREQUENCY, APRS®/GPS Set Mode 4: APRS MSG FLASH, 16: DIGI PASS, 21: MSG GROUP, 22: MY CALLSIGN, 23: MY POSITION, 24: MY SYMBOL VX-8GR OPERATING MANUAL 121 FCC ID: K6620415X20 / IC:511B-20415X20 CLONING The VX-8GR includes a convenient “Clone” feature, which allows the memory and configuration data from one transceiver to be transferred to another VX-8GR. This can be particularly useful when configuring a number of transceivers for a public service operation. Here is the procedure for Cloning one radio’s data to another: 1. Turn both radios off. 2. Connect the optional CT-144 Clone Cable between the DATA jacks of the two radios. 3. Press and hold in the f key while turning the radios on. Do this for both radios (the order of switch-on does not CLONE matter). “CLONE CLONE” will appear on the displays of both radios when the Clone mode is successfully activated in this step. 4. On the Destination radio, press the M key (“-- WAIT --” will appear on the LCD). 5. Press the B key on the Source radio; “-- - TX - --” will (Destination radio) appear on the Source radio, and the data from this radio will be transferred to the other radio. ERROR 6. If there is a problem during the cloning process, “ERROR ERROR” will be displayed. Check your cable connections and battery voltage, and try again. (Source radio) CLONE 7. If the data transfer is successful, “CLONE CLONE” will reappear on both displays. Turn both radios off and disconnect the Clone Cable. You can then turn the radios back on, and begin normal operation. DATA Jack DATA Jack CT-143 CloneCable (Option) 122 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 VX-8GR OPERATING MANUAL 123 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE GENERAL The VX-8GR Set Mode, already described in parts of many previous chapters, is easy to activate and set. It may be used for configuration of a wide variety of transceiver parameters, some of which have not been detailed previously. Use the following procedure to activate the Set Mode: 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item to be adjusted. 3. Press the m key briefly to enable adjustment of the Set Mode Item. 4. Rotate the DIAL knob to adjust or select the parameter to be changed on the Set Mode Item selected in above step. 5. After completing your selection and adjustment, press the PTT switch briefly to save the new setting and exit to normal operation. Some Set Mode Items (like Set Mode Item 91: TONE FREQUENCY) require that the m key be pressed after setting of the parameter, and before exiting to normal operation. CHANGING THE DISPLAY FORMAT OF THE SET MODE ITEM By factory default setting, the VX-8GR displays the Set Mode Item with “List” format in a Set Mode. You may change the display format of the Set Mode to our traditional “Item” format. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 81: SET MODE FORMAT FORMAT. 3. Press the key briefly to enable adjustment of this Set Mode Item. ITEM 4. Rotate the DIAL knob to select “ITEM ITEM”. 5. Press the PTT switch briefly to save the new setting and exit to normal operation. To return the display format to the “List”, repeat the above proLIST cedure, rotating the DIAL knob to select “LIST LIST” in step 4. (“LIST” format) 124 (“ITEM” format) VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE GENERAL CHANGING THE SET MODE CURSOR The VX-8GR has nine types of cursor symbol formats for the Set Mode operation. You may change the default setting to any of the available symbols. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 80: SET MODE CSR CSR. 3. Press the g key briefly to enable adjustment of this Set Mode Item. 4. Rotate the DIAL knob to select the desired cursor symbol type. , , , , , , , , or 5. When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. MASKING THE SET MODE ITEMS There may be situations where you want to “Mask” Set Mode Items so they are not recalled during Set Mode Item selection. 1. Press and hold the m key for one second to enter the Set Mode. 2. Rotate the DIAL knob to select Set Mode Item 30: EXTENDED MENU MENU. 3. Press the m key briefly to enable adjustment of this Set Mode Item. ON 4. Rotate the DIAL knob to select “ON ON”, then press the m key briefly. 5. Rotate the DIAL knob to select the Set Mode Item to be “Masked”. 6. Press the f key briefly. A “ ” icon will appear at the right side of the Set Mode Item Number in the display, indicating the Set Mode Item is to be Masked. 7. Repeat steps 5 and 6 above, to append the “ ” icon to any other Set Mode Item you wish to “Masked”. 8 When you have completed your selection, press the PTT switch to save the new setting and exit to normal operation. To unmask the hidden Set Mode Item, repeat the above procedure. In step 4 above select OFF “OFF OFF” and in step 6 above the “ ” icon will disappear from the Menu Item you wish to unmask. VX-8GR OPERATING MANUAL 125 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE FUNCTION AVAILABLE VALUES (DEFALT: BOLD ITALIC) 1: ANTENNA ATT 2: APO 3: ARTS BEEP 4: ARTS INTERVAL 5: BANK LINK 6: BANK NAME 7: BCLO 8: BEEP EDGE 9: BEEP LEVEL 10: BEEP MELODY 11: BEEP SELECT 12: BELL RINGER 13: BELL SELECT Enables/Disables the receiver Front-end Attenuator. Setting of the Automatic Power-Off time. Select the Beep option during ARTSTM operation. Select the Polling Interval during ARTSTM operation. Enables/Disables the Memory Bank Link Scan. Stores Alpha-Numeric “Tag” for the Memory Bank. Enables/disables the Busy Channel Lock-Out feature. Enables/disables the Band-edge beeper while selecting the frequency by the DIAL knob. Adjust the Beep volume level. Create the Beep Melody for Bell ringer function. Enables/Disables the keypad beeper. Selects the number of Bell ringer repetitions. Enables/Disables the Bell ringer function and its sound selection. 14: BUSY LED 15: CLOCK SHIFT 16: CW ID 17: CW LEARNING 18: CW PITCH 19: CW TRAINING 20: DC VOLTAGE 21: DCS CODE 22: DCS INVERSION Enables/Disables the BUSY LED while the squelch is open. Shifting of CPU clock frequency. Program and activate the CW Identifier (used during ARTSTM operation). Enables/Disables the CW Learning feature. Select the CW tone pitch for the CW Learning, CW Training, and CW Identifier functions. Enables/Disables the CW Training feature. Indicates the DC Supply Voltage. Setting of the DCS code. Enables/Disables the “Inverted” DCS tone. 23: DTMF DELAY 24: DTMF MANUAL/AUTO 25: DTMF SELECT 26: DTMF SPEED 27: EAI 28: EAI TIME Selects the DTMF Autodialer Delay Time. Enables/Disables the DTMF Autodial feature. Programming of the DTMF Autodialer. Selects the DTMF Autodialer Sending Speed. Enables/Disables the Emergency Automatic ID (EAI) feature. Sets the Emergency Automatic ID (EAI) operating mode and its transmit time. 29: EMERGENCY SELECT Select the alarms utilized when the Emergency function is engaged. 30: EXTENDED MENU 31: FW KEY HOLD TIME Enables/Disables the extended Set Mode Menu. Set the duration that a secondary function of the [F/W] key (press and holding the [F/W] key) is held determines the function they activate. Reducing the Deviation level by 50 %. Enables/Disables the function of the VFO DIAL knob, while in the Home Channel mode. Selects the primary function of the [H/M] key (press the [H/M] key). Enables/Disables the DTMF Autodialer feature while operating using the Internet Connection feature (WIRESTM). Enables/Disables the Internet Connection feature (WIRESTM). Selects the Access Number (DTMF digit) for the SRG operation of the Internet Connection feature (WIRESTM). Selects the primary function of the [INTERNET] key. ON / OFF 0.5hour - 12.0hour / OFF IN RANGE / ALWAYS / OFF 15sec / 25sec --ON / OFF ON / OFF LEVEL 1 ~ LEVEL 9 (LEVEL 5) -KEY & SCAN / KEY / OFF 1Time - 20Times / CONTINUOUS OFF / BELL / USER BP1 / USER BP2 / USER BP3 ON / OFF ON / OFF --400 - 1000 Hz (50 Hz/step) (700 Hz) --104 standard DCS codes (DCS 023) RX-NORMAL, TX-NORMAL / RX-INVERT, TX-NORMAL / RX-BOTH, TX-NORMAL / RX-NORMAL, TX-INVERT / RX-INVERT, TX-INVERT / RX-BOTH, TX-INVERT 50ms / 250ms / 450ms / 750ms / 1000ms MANUAL / AUTO -50ms / 100ms ON / OFF INT 1min ~ INT 9min / INT10min / INT15min / INT20min / INT30min / INT40min / INT50min / CON 1min ~ CON 9min / CON10min / CON15min / CON20min / CON30min / CON40min / CON50min (CON 5min) BEEP / STROBE / BEEP&STROBE / BEAM / BEEP&BEAM / CW / BEEP&CW / CW-ID TX ON / OFF FW0.3sec / FW0.5sec / FW0.7sec / FW1.0sec / FW1.5sec ON / OFF DISABLE / ENABLE HOME / REV MANUAL / AUTO SET MODE ITEM 32: HALF DEVIATION 33: HOME VFO 34: HOME/REVERSE 35: INT MANUAL/AUTO 36: INTERNET 37: INTERNET CODE 38: INTERNET KEY 39: INTERNET MODE 40: INTERNET SELECT 41: LAMP Selects the operating mode of the Internet Connection feature (WIRESTM). Programming of the Access Number (DTMF code) for the FRG station of the WIRESTM (or non WIRESTM Internet Link System) access. Selects the LCD/Keypad Lamp mode. 42: LANGUAGE 43: LCD CONTRAST 44: LCD DIMMER 45: LED LIGHT 46: LOCK Selects the language for the Set Mode selections. Setting of the Display contrast level. Setting of the Display brightness level. Illuminates the white LED light continuously (useful as emergency flashlight at night). Selects the Control Locking lockout combination. 47: MEMORY FAST STEP Selects the channel step for the fast channel selection mode while in the Memory Recall mode. Stores “Alpha-Numeric” tags for the Memory channels. Enables/Disables the Memory Write Protector. 48: MEMORY NAME 49: MEMORY PROTECT 126 ON / OFF DTMF 0 ~ DTMF 1, DTMF A ~ DTMF D, DTMF , DTMF # (DTMF 1) INTERNET / INTERNET SELECT / SET MODE FRG / SRG -KEY 2sec - KEY10sec / CONTINUOUS / OFF (KEY 5sec) ENGLISH / JAPANESE LEVEL 12 ~ LEVEL32 (LEVEL24) LEVEL 1 ~ LEVEL 4 -KEY / DIAL / KEY&DIAL / PTT / KEY&PTT / DIAL&PTT / ALL 10CH / 20CH / 50CH / 100CH -ON / OFF VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE ITEM FUNCTION 50: MEMORY SKIP 51: MEMORY WRITE 52: MESSAGE LIST 53: MESSAGE REGISTER 54: MESSAGE SELECT 55: MIC GAIN 56: MONI/T-CALL 57: MUTE Selects the Memory Scan channel-selection mode. Determines the method of selecting channels for Memory Storage. Programming a Member List for the Message feature. Selects your Personal ID for the Message feature. Programming a Message for the Message feature. Adjusts the microphone gain level. Selects the MONI key (just below the PTT switch) function. Adjusts the receiver audio output level when the MUTE function was activated. 58: OFF TIMER 59: ON TIMER 60: OPENING MESSAGE 61: PAGER ANS-BACK 62: PAGER CODE-RX 63: PAGER CODE-TX 64: PASSWORD 65: PR FREQUENCY 66: PRI REVERT 67: PRI TIME 68: PTT DELAY 69: RPT ARS 70: RPT SHIFT 71: RPT SHIFT FREQ 72: RX MODE 73: SAVE RX Set the OFF Timer time. Set the ON Timer time. Selects the Opening Message that appears when the radio is powered on. Enables/Disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch. Sets the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch. Sets the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch. Programming and activating the Password feature. Program the CTCSS Tone Frequency for the User Programmed Reverse CTCSS Decoder. Enables/Disables the Priority Revert feature. Selects the time between the Priority (Dual Watch) channel checks, when the feature is active. Selects the time delay before the carrier is transmitted, when the PTT switch is pressed. Enables/Disables the Automatic Repeater Shift function. Sets the Repeater Shift Direction. Sets the magnitude of the Repeater Shift. Sets the receiving mode. Selects the Receive-mode Battery Saver interval (“sleep” ratio). 74: SAVE TX 75: SCAN LAMP 76: SCAN RE-START Enables/Disables the Transmitter Battery Saver. Enables/Disables the Scan Lamp (while scanner is paused). Selects the Scan Re-start Delay time. 77: SCAN RESUME Selects the Scan Resume mode. 78: SENSOR DISPLAY 79: SENSOR INFO 80: SET MODE CSR 81: SET MODE FORMAT 82: SMART SEARCH 83: S-METER SYMBOL 84: SPEC-ANALYZER 85: SQL LEVEL 86: SQL S-METER 87: SQL SPLIT 88: SQL TYPE Selects the sensor information when the transceiver is operating in the “Mono” band mode with large characters. Indicates the Information of the internal sensors. Selects the Set Mode Cursor. Selects the display format of the Set Mode operation. Selects the Smart Search Sweep mode. Selects the S- & TX PO meter Symbol. Selects the Spectrum Analyzer sweep mode. Sets the Squelch threshold level. Adjusts the Squelch threshold level to the S-meter level. Enables/disables split CTCSS/DCS coding. Selects the Tone Encoder and/or Decoder mode. 89: STEP FREQUENCY Setting of the DIAL frequency steps. 90: TIME SET 91: TONE FREQUENCY 92: TONE-SRCH MUTE 93: TONE-SRCH SPEED 94: TOT Sets the Clock time. Setting of the CTCSS Tone Frequency Enables/Disables the receiver audio output while the Tone Search Scanner is activated. Selects the Tone Search Scanner speed. Setting of the TOT time 95: VFO MODE Selects or disables the VFO band edge limiting for the current band. 96: VFO SKIP Setting My Band. 97: VIBRATOR Enables/Disables the Vibrator function. 98: VIBRATOR MODE Selects the vibration mode of the Vibrator function. 99: VOLUME MODE Select the [VOL] key function. 100: WX ALERT Enables/Disables the Weather Alert Feature 1: Depends on the transceiver version. 2: Depends on the operating band and transceiver version. VX-8GR OPERATING MANUAL AVAILABLE VALUES (DEFALT: UNDERLINED BOLD) OFF / SKIP / ONLY NEXT / LOWER ---LEVEL 1 ~ LEVEL 9 (LEVEL 5) MONI / T-CALL1 MUTE 30%, MUTE 50%, MUTE 100%, or OFF --NORMAL / OFF / DC / MESSAGE ON / OFF ---300Hz ~ 3000Hz (1000Hz/step) (1600Hz) ON / OFF 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step) (5.0sec) OFF / 20ms / 50ms / 100ms / 200ms ON / OFF SIMPLEX / -RPT / +RPT 0.000MHz ~ 150.000MHz (50 kHz/step)2 AUTO / NFM / AM 0.2sec ~ 0.9sec (0.1sec/step), 1.0sec ~ 9.5sec (0.5sec/step), or 10.0sec ~ 60.0sec (5sec/step) ON / OFF ON / OFF 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step) (2.0sec) 2.0sec ~ 10.0sec (0.5sec/step) /BUSY / HOLD (5.0sec) DC / TEMP / WAVE / BARO / ALTI / OFF -Nine patterns LIST / ITEM SINGLE / CONTINUOUS Four patterns 1Time / CONTINUOUS / Full Time LEVEL 0 ~ LEVEL 15 (LEVEL 1) OFF / LEVEL 0 ~ LEVEL 9 OFF / ON OFF / TONE / TONE SQL / DCS / REV TONE / PR FREQ / PAGER / MESSAGE AUTO / 5.0 / 6.25 / 8.33 / 9.0 / 10.0 / 12.5 / 15.0 / 20.0 / 25.0 / 50.0 / 100.0 kHz -50 standard CTCSS tones (100.0Hz) ON / OFF FAST (2.5 tone/sec) / SLOW (1.25 tone/sec) OFF / 0.5min ~ 10.0min (0.5min/step) (3.0min) ALL / BAND -OFF / BUSY / SIGNALING MODE1 / MODE2 / MODE3 NORMAL / AUTO BACK ON / OFF 127 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE REPEATER SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) CTCSS/DCS/EPCS SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) Enables/Disables the Automatic Repeater Shift function. Sets the Repeater Shift Direction. Sets the magnitude of the Repeater Shift. Selects the number of Bell ringer repetitions. Enables/Disables the Bell ringer function and its sound selection. Setting of the DCS code. Enables/Disables the “Inverted” DCS tone. Enables/Disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch. Sets the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch. Sets the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch. Program the CTCSS Tone Frequency for the User Programmed Reverse CTCSS Decoder. Enables/Disables split CTCSS/DCS coding. Selects the Tone Encoder and/or Decoder mode. Setting of the CTCSS Tone Frequency Enables/Disables the receiver audio output while the Tone Search Scanner is activated. Selects the Tone Search Scanner speed. 69: RPT ARS 70: RPT SHIFT 71: RPT SHIFT FREQ 12: BELL RINGER 13: BELL SELECT 21: DCS CODE 22: DCS INVERSION 61: PAGER ANS-BACK 62: PAGER CODE-RX 63: PAGER CODE-TX 65: PR FREQUENCY 87: SQL SPLIT 88: SQL TYPE 91: TONE FREQUENCY 92: TONE-SRCH MUTE 93: TONE-SRCH SPEED ON / OFF SIMPLEX / -RPT / +RPT 0.000MHz ~ 150.000MHz (50 kHz/step) 1 1time - 20times / CONTINUOUS OFF / BELL / USER BP1 / USER BP2 / USER BP3 104 standard DCS codes (DCS 023) RX-NORMAL, TX-NORMAL / RX-INVERT, TX-NORMAL / RX-BOTH, TX-NORMAL / RX-NORMAL, TX-INVERT / RX-INVERT, TX-INVERT / RX-BOTH, TX-INVERT ON / OFF --300 Hz ~ 3000 Hz (1000 Hz/step) (1600 Hz) OFF / ON OFF / TONE / TONE SQL / DCS / REV TONE / PR FREQ / PAGER / MESSAGE 50 standard CTCSS tones (100.0Hz) ON / OFF FAST (2.5 tone/sec) / SLOW (1.25 tone/sec) ARTSTM SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) MEMORY S ETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) SCAN SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) Select the Beep option during ARTSTM operation. Select the Polling Interval during ARTSTM operation. Program and activate the CW Identifier (used during ARTSTM operation). Enables/Disables the Memory Bank Link Scan. Stores Alpha-Numeric “Tag” for the Memory Bank. Selects the channel step for the fast channel selection mode while in the Memory Recall mode. Stores “Alpha-Numeric” tags for the Memory channels. Enables/Disables the Memory Write Protector. Determines the method of selecting channels for Memory Storage. Selects the Memory Scan channel-selection mode. Enables/Disables the Scan Lamp (while scanner is paused). Selects the Scan Re-start Delay time. 3: ARTS BEEP 4: ARTS INTERVAL 16: CW ID 5: BANK LINK 6: BANK NAME 47: MEMORY FAST STEP 48: MEMORY NAME 49: MEMORY PROTECT 51: MEMORY WRITE 50: MEMORY SKIP 75: SCAN LAMP 76: SCAN RE-START Selects the Receive-mode Battery Saver interval (“sleep” ratio). 77: SCAN RESUME Enables/Disables the Priority Revert feature. Selects the time between the Priority (Dual Watch) channel checks, when the feature is active. 66: PRI REVERT 67: PRI TIME BATTERY SAVING SETTING Setting of the Automatic Power-Off time. Enables/Disables the BUSY LED while the squelch is open. Selects the Receive-mode Battery Saver interval (“sleep” ratio). Enables/Disables the Transmitter Battery Saver. SET MODE ITEM 2: APO 14: BUSY LED 73: SAVE RX 74: SAVE TX IN RANGE / ALWAYS / OFF 15sec / 25sec -- --10CH / 20CH / 50CH / 100CH -ON / OFF NEXT / LOWER OFF / SKIP / ONLY ON / OFF 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step) (5.0sec) 2.0sec ~ 10.0sec (0.5sec/step) / BUSY / HOLD (5.0sec) ON / OFF 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step) (5.0sec) AVAILABLE VALUES (DEFAULT: BOLD ITALIC) 0.5hour - 12.0hour / OFF ON / OFF 0.2sec ~ 0.9sec (0.1sec/step), 1.0sec ~ 9.5sec (0.5sec/step), or 10.0sec ~ 60.0sec (5sec/step) ON / OFF MESSAGE SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) WIRESTM SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) Programming a Member List for the Message feature. Selects your Personal ID for the Message feature. Programming a Message for the Message feature. 52: MESSAGE LIST 53: MESSAGE REGISTER 54: MESSAGE SELECT Enables/Disables the DTMF Autodialer feature while using the Internet Connection feature (WIRESTM). 35: INT MANUAL/AUTO Enables/Disables the Internet Connection feature (WIRESTM). 36: INTERNET Selects the Access Number (DTMF digit) for SRG operation of the Internet Connection feature (WIRESTM). 37: INTERNET CODE Selects the primary function of the [INTERNET] key. 38: INTERNET KEY 39: INTERNET MODE Selects the operating mode of the Internet Connection feature (WIRESTM). Programming of the Access Number (DTMF code) for the FRG station of the WIRES TM (or non WIRESTM 40: INTERNET SELECT Internet Link System) access. EAI SETTING Enables/Disables the Emergency Automatic ID (EAI) feature. Sets the Emergency Automatic ID (EAI) operating mode and its transmit time. Select the alarms utilized when the Emergency function is engaged. 128 SET MODE ITEM 27: EAI 28: EAI TIME 29: EMERGENCY SELECT ---- MANUAL / AUTO ON / OFF DTMF 0 ~ DTMF 9, DTMF A ~ DTMF D, DTMF , or DTMF # (DTMF 1) INTERNET / INT SELECT / SET MODE FRG / SRG -- AVAILABLE VALUES (DEFAULT: BOLD ITALIC) ON / OFF INT 1min ~ INT 9min, INT10min, INT15min, INT20min, INT30min, INT40min, INT50min, CON 1min ~ CON 9min, CON10min, CON15min, CON20min, CON30min, CON40min, CON50min, (CON 5min) BEEP / STROBE / BEEP & STROBE / BEAM / BEEP & BEAM / CW / BEEP & CW / CW-ID TX VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE VIBRATOR SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) DTMF SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) SWITCH/KNOB SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) Enables/Disables the Vibrator function. Selects the vibration mode of the Vibrator function. Selects the DTMF Autodialer Delay Time. Enables/Disables the DTMF Autodial feature. Programming the DTMF Autodialer. Selects the DTMF Autodialer Sending Speed. 97: VIBRATOR 98: VIBRATOR MODE 23: DTMF DELAY 24: DTMF MANUAL/AUTO 25: DTMF SELECT 26: DTMF SPEED Set the duration that a secondary function of the [F/W ] key (press and holding the [F/W ] key) is held 31: FW KEY HOLD TIME determines the function they activate. 34: HOME/REVERSE Selects the function of the [H/M] key. 46: LOCK Selects the Control Locking lockout combination. Selects the MONI key (just below the PTT switch) function. Selects the time delay before the carrier is transmitted, when the PTT switch is pressed. Select the [VOL] key function. DISPLAY SETTING Indicates the DC Supply Voltage. Selects the LCD/Keypad Lamp mode. Setting the Display contrast level. Setting the Display brightness level. Illuminates the white LED light continuously (useful as emergency flashlight at night). Selects the Opening Message that appears when the radio is powered on. Selects the sensor information when the transceiver is operating in the “Mono” band mode with large character. Displays internal sensor information. Selects the S- & TX PO meter Symbol. Selects the Spectrum Analyzer sweep mode. 56: MONI/T-CALL 68: PTT DELAY 99: VOLUME MODE SET MODE ITEM 20: DC VOLTAGE 41: LAMP 43: LCD CONTRAST 44: LCD DIMMER 45: LED LIGHT 60: OPENING MESSAGE 78: SENSOR DISPLAY OFF / BUSY / SIGNALING MODE1 / MODE2 / MODE3 50ms / 250ms / 450ms / 750ms / 1000ms MANUAL / AUTO -50mS / 100mS 0.3sec / 0.5sec / 0.7sec / 1.0sec / 1.5sec HOME / REV KEY / DIAL / KEY&DIAL / PTT / KEY&PTT / DIAL&PTT / ALL MONI / T-CALL2 OFF / 20ms / 50ms / 100ms / 200ms NORMAL / AUTO BACK AVAILABLE VALUES (DEFAULT: BOLD ITALIC) -KEY 2sec - KEY 10sec / CONTINUOUS / OFF (KEY 5sec) LEVEL 12 ~ LEVEL32 (LEVEL24) LEVEL 1 ~ LEVEL 4 -NORMAL / OFF / DC / MESSAGE DC / TEMP / WAVE / BARO / ALTI / WX / OFF 79: SENSOR INFORMATION -83: S-METER SYMBOL Four patterns 84: SPEC-ANALYZER 1Time / Continuous / Full Time BEEP SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) MISCELLANEOUS SETTING SET MODE ITEM AVAILABLE VALUES (DEFAULT: BOLD ITALIC) Enables/Disables the Band-edge beeper while selecting the frequency with the DIAL knob. Adjust the Beep volume level. Create the Beep Melody for Bell ringer function. Enables/Disables the keypad beeper. Select the CW tone pitch for the CW Learning, CW Training, and CW Identifier functions. Enables/Disables the receiver Front-end Attenuator. Enables/Disables the Busy Channel Lock-Out feature. Shifting of CPU clock frequency. Enables/Disables the CW Learning feature. Enables/Disables the CW Training feature. Enables/Disables the extended Set Mode Menu. Reducing the Deviation level by 50 %. Enables/Disables the function of the VFO DIAL knob, while in the Home Channel mode. Selects the language for the Set Mode selections. Adjusts the microphone gain level. Adjusts the receiver audio output level when the MUTE function was activated. Set the OFF Timer time. Set the ON Timer time. Programming and activating the Password feature. Sets the receiving mode. Selects the Set Mode Cursor. Selects the display format of the Set Mode operation. Selects the Smart Search Sweep mode. Sets the Squelch threshold level. Adjusts the Squelch threshold level to the S-meter level. Setting of the DIAL frequency steps. Sets the Clock time. Setting of the TOT time Selects or disables the VFO band edge limiting for the current band. Set My Band. Enables/Disables the Weather Alert Feature 8: BEEP EDGE 9: BEEP LEVEL 10: BEEP MELODY 11: BEEP SELECT 18: CW PITCH 1: ANTENNA ATT 7: BCLO 15: CLOCK SHIFT 17: CW LEARNING 19: CW TRAINING 30: EXTENDED MENU 32: HALF DEVIATION 33: HOME VFO 42: LANGUAGE 55: MIC GAIN 57: MUTE 58: OFF TIMER 59: ON TIMER 64: PASSWORD 72: RX MODE 80: SET MODE CSR 81: SET MODE FORMAT 82: SMART SEARCH 8 SQL LEVEL 86: SQL S-METER 89: STEP FREQUENCY 90: TIME SET 95: TOT 96: VFO MODE 97: VFO SKIP 100: WX ALERT ON / OFF LEVEL 1 - LEVEL 9 (LEVEL 5) -KEY & SCAN / KEY / OFF 400 - 1000 Hz (50 Hz/step) (700 Hz) ON / OFF ON / OFF ON / OFF --ON / OFF ON / OFF DISABLE / ENABLE ENGLISH / JAPANESE LEVEL 1 ~ LEVEL 9 (LEVEL 5) MUTE 30%,MUTE 50%, MUTE 100%, or OFF ---AUTO / NFM / AM / WFM Nine patterns LIST / ITEM SINGLE / CONTINUOUS LEVEL 0 ~ LEVEL 15 (LEVEL 1) OFF / LEVEL 0 ~ LEVEL 9 AUTO / 5.0 /6.25 / 8.33 / 9.0 / 10.0 / 12.5 / 15.0 / 20.0 / 25.0 / 50.0 / 100 kHz -OFF / 0.5min ~ 10.0min (0.5min/step) (3.0min) ALL / BAND -ON / OFF 1: Depends on the operating band and transceiver version. 2: Depends on the transceiver version. VX-8GR OPERATING MANUAL 129 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 1: ANTENNA ATT Function: Enables/Disables the receiver Front-end Attenuator. Available Values: ON / OFF Default: OFF Note: This Menu Item can select and set to each operating band and frequency band individually. SET MODE ITEM 2: APO Function: Setting of the Automatic Power-Off time. Available Values: 0.5hour ~ 12.0hour / OFF Default: OFF SET MODE ITEM 3: ARTS BEEP Function: Select the Beep option during ARTS operation. Available Values: IN RANGE / ALWAYS / OFF Default: IN RANGE IN RANGE: Beeps sound only when the radio first detects that you are within range. ALWAYS: Beeps sound every time a polling transmission is received from the other station (every 15 or 25 seconds when in range). OFF: No alert beeps sound. SET MODE ITEM 4: ARTS INTERVAL Function: Select the Polling Interval during ARTS operation. Available Values: 15sec / 25sec Default: 25sec This setting determines how often the other station will be polled during ARTS operation. SET MODE ITEM 5: BANK LINK Function: Enables/Disables the Memory Bank Link Scan. See page ?? for details. SET MODE ITEM 6: BANK NAME Function: Stores Alpha-Numeric “Tag” for the Memory Bank. See page ?? for details. SET MODE ITEM 7: BCLO Function: Enables/Disables the Busy Channel Lock-Out feature. Available Values: ON / OFF Default: OFF 130 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 8: BEEP EDGE Function: Enables/Disables the Band-edge beeper while selecting the frequency by the DIAL knob. Available Values: ON / OFF Default: OFF Note: When this Set Mode Item is set to “ON”, a beep will sound when the frequency reaches the band edge while selecting the VFO frequency with the DIAL knob. SET MODE ITEM 9: BEEP LEVEL Function: Adjust the Beep volume level. Available Values: LEVEL 1 ~ LEVEL 9 Default: LEVEL 5 SET MODE ITEM 10: BEEP MELODY Function: Create the Beep Melody for Bell ringer function. See page 43 for details. SET MODE ITEM 11: BEEP SELECT Function: Enables/Disables the keypad beeper. Available Values: KEY & SCAN / KEY / OFF Default: KEY & SCAN KEY & SCAN: The beeper sounds when you press a key or when the scanner stops. KEY: The beeper sounds when you press a key. OFF: The beeper is disabled. SET MODE ITEM 12: BELL RINGER Function: Selects the number of Bell ringer repetitions. Available Values: 1Time ~ 20Times / CONTINUOUS Default: 1Time SET MODE ITEM 13: BELL SELECT Function: Enables/Disables the Bell ringer function and its sound selection. Available Values: OFF / BELL / USER BP1 / USER BP2 / USER BP3 Default: OFF SET MODE ITEM 14: BUSY LED Function: Enables/Disables the BUSY LED while the squelch is open. Available Values: ON / OFF Default: ON VX-8GR OPERATING MANUAL 131 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 15: CLOCK SHIFT Function: Shifting of CPU clock frequency. Available Values: ON / OFF Default: OFF Note: This function is only used to move a spurious response “birdie”, should it fall on a desired frequency. SET MODE ITEM 16: CW ID Function: Program and activate the CW Identifier (used during ARTS™ operation). See page xx for details. SET MODE ITEM 17: CW LEARNING Function: Enables/Disables the CW Learning feature. See page xx for details. SET MODE ITEM 18: CW PITCH Function: Select the CW tone pitch for the CW Learning, CW Training, and CW Identifier functions. Available Values: 400 ~ 1000 Hz (50 Hz/step) Default: 700Hz SET MODE ITEM 19: CW TRAINING Function: Enables/Disables the CW Training feature. See page xx for details. SET MODE ITEM 20: DC VOLTAGE Function: Indicates the DC Supply Voltage. SET MODE ITEM 21: DCS CODE Function: Setting of the DCS code. Available Values: 104 standard DCS codes. Default: DCS 023 DCS CODE 023 025 026 031 032 036 043 047 051 053 054 065 071 072 073 074 114 115 116 122 125 131 132 134 143 145 152 155 156 162 165 172 174 205 212 223 225 226 243 244 245 246 251 252 255 261 263 265 266 271 274 306 311 315 325 331 332 343 346 351 356 364 365 371 411 412 413 423 431 432 445 446 452 454 455 462 464 465 466 503 506 516 523 526 532 546 565 606 612 624 627 631 632 654 662 664 703 712 723 731 732 734 743 754 132 – – – – – – VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 22: DCS INVERSION Function: Enables/Disables the “Inverted” DCS tone. Available Values: RX-NORMAL, TX-NORMAL / RX-INVERT, TX-NORMAL / RX-BOTH, TX-NORMAL / RX-NORMAL, TX-INVERT / RX-INVERT, TX-INVERT / RX-BOTH, TX-INVERT Default: RX-NORMAL, TX-NORMAL RX-NORMAL, TX-NORMAL: Receive and transmit the Normal DCS Tone. RX-INVERT, TX-NORMAL: Receive the Inverted DCS Tone and transmit the Normal DCS Tone. RX-BOTH, TX-NORMAL: Receive both Normal and Inverted DCS Tones and transmit the Normal DCS Tone. RX-NORMAL, TX-INVERT: Receive the Normal DCS Tone and transmit the Inverted DCS Tone. RX-INVERT, TX-INVERT: Receive and transmit the Inverted DCS Tone. RX-BOTH, TX-INVERT: Receive both Normal and Inverted DCS Tones and transmit the Inverted DCS Tone. SET MODE ITEM 23: DTMF DELAY Function: Selects the DTMF Autodialer Delay Time. Available Values: 50ms / 250ms / 450ms / 750ms / 1000ms Default: 450ms SET MODE ITEM 24: DTMF MANUAL/AUTO Function: Enables/Disables the DTMF Autodial feature. Available Values: MANUAL / AUTO Default: MANUAL SET MODE ITEM 25: DTMF SELECT Function: Programming of the DTMF Autodialer. See page xx for details. SET MODE ITEM 26: DTMF SPEED Function: Selects the DTMF Autodialer Sending Speed. Available Values: 50mS / 100mS Default: 50mS SET MODE ITEM 27: EAI Function: Enables/Disables the Emergency Automatic ID (EAI) feature. Available Values: ON / OFF Default: OFF VX-8GR OPERATING MANUAL 133 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 28: EAI TIME Function: Sets the Emergency Automatic ID (EAI) operating mode and its transmit time. Available Values: INT 1min ~ INT 9min / INT10min / INT15min / INT20min / INT30min / INT40min / INT50min / CON 1min ~ CON 9min / CON10min / CON15min / CON20min / CON30min / CON40min / CON50min Default: CON 5min INT: Interval Mode CON: Continuous Mode SET MODE ITEM 29: EMERGENCY SELECT Function: Select the alarms utilized when the Emergency function is engaged. Available Values: BEEP / STROBE / BEEP&STROBE / BEAM / BEEP&BEAM / CW / BEEP&CW / CW-ID TX Default: BEEP & STROBE BEEP: Loud “Alarm” sounds. STROBE: Flashes the white LED light. BEEP&STROBE: Loud “Alarm” sounds along with flashing of the white LED light. BEAM: The white LED light glows continuously. BEEP&BEAM: Loud “Alarm” sounds and the white LED light glows continuously. CW: The white LED light flashes according to the programmed Emergency message (Morse Code) at a rate of five words per minute. BEEP&CW: Sounds tones via the speaker, and flashes the white LED light, according to the programmed Emergency message (Morse Code) at a rate of five words per minute. CW-ID TX: Transmits the programmed Emergency message (Morse Code) and flashes the white LED light, according to the programmed Emergency message (Morse Code) on the air beginning one minute after activation of the Emergency function. : The internationally-recognized Morse Code “S.O.S” message (• • • – – – • • •) is programmed at the factory for the Emergency message. Here’s how to program the Emergency Message: 1. Press the M key to display any previously-stored emergency message. 2. Press and hold the h key for two seconds to clear any previous emergency message, if desired. 3. Rotate the DIAL knob, or press one of the keyboard keys, to select the first letter/ number of the message. Example 1: Rotate the DIAL knob to select any of the 39 available characters. Example 2: Press the 2 key repeatedly to toggle among the four available characters associated with that key: A B C 2 134 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS 4. Press the M key to move to the next character, if needed. 5. Repeat previous steps 3 and 4 to complete the message (up to 16 characters). 6. If you make a mistake, press the B key to backspace the cursor; now re-enter the correct letter/number. 7. Press and hold the h key for two seconds to delete all data after the cursor that may have been previously stored erroneously. 8. When you have entered the message, press the M key again to confirm the message, then press the PTT switch to save the settings and exit to normal operation. SET MODE ITEM 30: EXTENDED MENU Function: Enables/Disables the extended Set Mode Menu. Available Values: ON / OFF Default: OFF SET MODE ITEM 31: FW KEY HOLD TIME Function: Set the duration time that the f key must be held to activate the secondary function. Available Values: FW0.3sec / FW0.5sec / FW0.7sec / FW1.0sec / FW1.5sec Default: FW0.5sec SET MODE ITEM 32: HALF DEVIATION Function: Reducing the Deviation level by 50 %. Available Values: ON/OFF Default: OFF SET MODE ITEM 33: HOME VFO Function: Enables/Disables the function of the VFO DIAL knob, while in the Home Channel mode. Available Values: DISABLE / ENABLE Default: ENABLE SET MODE ITEM 34: HOME/REVERSE Function: Selects the function of the h key. Available Values: HOME / REV Default: REV HOME: Pressing the h key instantly recalls a favorite “Home” channel. REV: Pressing the h key reverses transmit and receive frequencies during repeater operation. VX-8GR OPERATING MANUAL 135 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 35: INT MANUAL/AUTO Function: Enables/Disables the DTMF Autodialer feature while using the Internet Connection feature (WIRESTM). Available Values: MANUAL / AUTO Default: MANUAL SET MODE ITEM 36: INTERNET Function: Enables/Disables the Internet Connection feature (WIRESTM). Available Values: ON / OFF Default: OFF SET MODE ITEM 37: INTERNET CODE Function: Selects the Access Number (DTMF digit) for SRG operation of the Internet Connection feature (WIRESTM). Available Values: DTMF 0 ~ DTMF 9, DTMF A ~ DTMF D, DTMF , or DTMF # Default: DTMF 1 SET MODE ITEM 38: INTERNET KEY Function: Selects the primary function of the d key. Available Values: INTERNET / INTERNET SELECT / SET MODE Default: INTERNET INTERNET: The d key Enables/Disables the internet feature. INTERNET SELECT: The d key recalls the Internet Access Number (SRG) or Access String (FRG). (SRG) or (FRG) is determined via Set Mode Item 39: INTERNET MODE. SET MODE: The d key is the Short-cut path to recall one of the Set Mode Items. See page xx for programming. SET MODE ITEM 39: INTERNET MODE Function: Selects the operating mode of the Internet Connection feature (WIRESTM). Available Values: FRG / SRG Default: SRG SET MODE ITEM 40: INTERNET SELECT Function: Programming of the Access Number (DTMF code) for the FRG station of the WIRESTM (or non WIRESTM Internet Link System) access. See page xx for details. 136 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 41: LAMP Function: Selects the LCD/Keypad Lamp mode. Available Values: KEY 2sec ~ KEY10sec / CONTINUOUS / OFF Default: KEY 5sec KEY 2sec ~ KEY10sec: Illuminates the LCD/Keypad for the selected time, when any key is pressed. CONTINUOUS: Illuminates the LCD/Keypad continuously. OFF: Disables the LCD/Keypad illumination SET MODE ITEM 42: LANGUAGE Function: Selects the language for the Set Mode selections. Available Values: ENGLISH / JAPANESE Default: ENGLISH SET MODE ITEM 43: LCD CONTRAST Function: Setting of the Display contrast level. Available Values: LEVEL 12 ~ LEVEL32 Default: LEVEL24 SET MODE ITEM 44: LCD DIMMER Function: Setting of the Display brightness level. Available Values: LEVEL 1 ~ LEVEL 4 Default: LEVEL 4 SET MODE ITEM 45: LED LIGHT Function: Illuminates the white LED light continuously (useful as emergency flashlight at night). SET MODE ITEM 46: LOCK Function: Selects the combination of key buttons that are locked out by the LOCK function. Available Values: KEY / DIAL / KEY&DIAL / PTT / KEY&PTT / DIAL&PTT / ALL Default: KEY&DIAL SET MODE ITEM 47: MEMORY FAST STEP Function: Selects the channel step for the fast channel selection mode while in the Memory Recall mode. Available Values: 10CH / 20CH / 50CH / 100CH Default: 10CH VX-8GR OPERATING MANUAL 137 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 48: MEMORY NAME Function: Stores “Alpha-Numeric” tags for the Memory channels. See page xx for details. SET MODE ITEM 49: MEMORY PROTECT Function: Enables/Disables the Memory Write Protector. Available Values: ON/OFF Default: OFF Note: When this Set Mode Item is set to “ON”, the memory write operation is ignored. SET MODE ITEM 50: MEMORY SKIP Function: Selects the Memory Scan channel-selection mode. Available Values: OFF / SKIP / ONLY Default: OFF OFF: All memory channels will be scanned (the “flag” will be ignored). SKIP: The scanner will “skip” the flagged channels during scanning. ONLY: The scanner will only scan channels that are flagged (Preferential Scan List). SET MODE ITEM 51: MEMORY WRITE Function: Determines the method of selecting channels for Memory Storage. Available Values: NEXT / LOWER Default: NEXT NEXT: Stores the data into the memory channel, which is next highest from the laststored memory channel. LOWER: Stores the data into the next-available “free” channel. SET MODE ITEM 52: MESSAGE LIST Function: Programming a Member List for the Message feature. See page xx for details. SET MODE ITEM 53: MESSAGE REGISTER Function: Selects your Personal ID for the Message feature. See page xx for details. SET MODE ITEM 54: MESSAGE SELECT Function: Programming a Message for the Message feature. See page xx for details. 138 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 55: MIC GAIN Function: Adjusts the microphone gain level. Available Values: LEVEL 1 ~ LEVEL 9 Default: LEVEL 5 SET MODE ITEM 56: MONI/T-CALL Function: Selects the e key (just below the PTT switch) function. Available Values: MONI/T-CALL Default: Depends on the transceiver version. MONI: Pressing the e key causes the Noise/Tone Squelch to be over-ridden, allowing you to listen for weak (or non-encoded) signals. T-CALL: Pressing the e key activates a 1750-Hz burst tone, used for repeater access in many countries. SET MODE ITEM 57: MUTE Function: Adjusts the receiver audio output level when the MUTE function was activated. Available Values: MUTE 30%, MUTE 50%, MUTE 100%, or OFF Default: OFF SET MODE ITEM 58: OFF TIMER Function: Set the OFF Timer time. The OFF Timer turns the radio off at the programmed time. See page xx for details. SET MODE ITEM 59: ON TIMER Function: Set the ON Timer time. The ON Timer turns the radio on at the programmed time. See page xx for details. SET MODE ITEM 60: OPENING MESSAGE Function: Selects the Opening Message that appears when the radio is powered on. Available Values: NORMAL / OFF / DC / MESSAGE Default: NORMAL NORMAL: Appears the Vertex Standard Logo. OFF: No Opening Message. DC: Appears the Vertex Standard Logo with the current time and the power supply voltage. MESSAGE: The Vertex Standard Logo appears along with your message. See the following procedure for creating a message. Here’s how to program the Opening Message. 1. Select this Set Mode Item to “MESSAGE”. 2. Press the M key to enable programming of the Opening Message. You will notice VX-8GR OPERATING MANUAL 139 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS the first character entry location blinking. 3. Rotate the DIAL knob, or press one of the keyboard keys, to select the first letter, number, or symbol of the message. Example 1: Rotate the DIAL knob to select any of the 61 available characters. Example 2: Press the 2 key repeatedly to toggle among the seven available characters associated with that key: a b c 2 A B C 4. Press the M key to move to the next character, if needed. 5. Repeat previous steps 3 and 4 to complete the message (up to 16 characters). 6. If you make a mistake, press the B key to back-space the cursor; now re-enter the correct letter, number, or symbol. 7. When you have entered the desired Opening Message, press the m key to save the new settings. SET MODE ITEM 61: PAGER ANS-BACK Function: Enables/Disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch. Available Values: ON / OFF Default: OFF SET MODE ITEM 62: PAGER CODE-RX Function: Sets the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch. See page xx for details. SET MODE ITEM 63: PAGER CODE-TX Function: Sets the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch. See page xx for details. SET MODE ITEM 64: PASSWORD Function: Programming and activating the Password feature. See page xx for details. SET MODE ITEM 65: PR FREQUENCY Function: Program the CTCSS Tone Frequency for the User Programmed Reverse CTCSS Decoder. Available Values: 300 Hz ~ 3000 Hz (100 Hz/step) Default: 1600 Hz SET MODE ITEM 66: PRI REVERT Function: Enables/Disables the Priority Revert feature. Available Values: ON / OFF Default: OFF 140 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 67: PRI TIME Function: Selects the time between the Priority (Dual Watch) channel checks, when the feature is active. Available Values: 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step) Default: 5.0sec SET MODE ITEM 68: PTT DELAY Function: Selects the time delay before the carrier is transmitted, when the PTT switch is pressed. Available Values: OFF / 20ms / 50ms / 100ms / 200ms Default: OFF SET MODE ITEM 69: RPT ARS Function: Enables/Disables the Automatic Repeater Shift function. Available Values: ON / OFF Default: ON SET MODE ITEM 70: RPT SHIFT Function: Sets the Repeater Shift Direction. Available Values: SIMPLEX / –RPT / +RPT Default: SIMPLEX SET MODE ITEM 71: RPT SHIFT FREQ Function: Sets the magnitude of the Repeater Shift. Available Values: 0.000MHz ~ 150.000MHz (50 kHz/step) Default: Depends on the operating band and transceiver version. SET MODE ITEM 72: RX MODE Function: Sets the receiving mode. Available Values: AUTO / NFM / AM Default: AUTO (Mode automatically changes according to operating frequency). SET MODE ITEM 73: SAVE RX Function: Selects the Receive-mode Battery Saver interval (“sleep” ratio). Available Values: 0.2sec ~ 0.9sec (0.1sec/step), 1.0sec ~ 9.5sec (0.5sec/step), or 10.0sec ~ 60.0sec (5sec/step) Default: 0.2sec SET MODE ITEM 74: SAVE TX Function: Enables/Disables the Transmitter Battery Saver. Available Values: ON / OFF Default: OFF VX-8GR OPERATING MANUAL 141 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 75: SCAN LAMP Function: Enables/Disables the Scan Lamp (while scanner is paused). Available Values: ON / OFF Default: ON SET MODE ITEM 76: SCAN RE-START Function: Selects the Scan Re-start Delay time. Available Values: 0.1sec ~ 0.9sec (0.1sec/step) or 1.0sec ~ 10.0sec (0.5sec/step) Default: 2.0sec SET MODE ITEM 77: SCAN RESUME Function: Selects the Scan Resume mode. Available Values: 2.0sec ~ 10.0sec (0.5sec/step) /BUSY / HOLD Default: 5.0sec 2.0sec - 10.0sec: The scanner will halt on a signal it encounters, and will hold there for the selected resume time. If you do not take action to disable the scanner within that time period, the scanner will resume even if the station is still active. BUSY: The scanner will halt on a signal it encounters. When the signal drops, the scanner will resume. The Scan resume time (default 2 seconds) is controlled set by the Set Mode Item 76: SCAN RE-START. HOLD: The scanner will halt on a signal it encounters. It will not restart automatically; you must manually re-initiate scanning if you wish to resume. SET MODE ITEM 78: SENSOR DISPLAY Function: Selects the sensor information when the transceiver is operating in the “Mono” band mode with large characters. Available Values: DC / TEMP/ OFF Default: DC DC: Indicates the battery voltage and battery type. TEMP: Indicates the current temperature inside the transceiver’s case. OFF: Disables the sensor information (Indicates the “Current Time” only). SET MODE ITEM 79: SENSOR INFO Function: Indicates the information of the internal sensors. SET MODE ITEM 80: SET MODE CSR Function: Selects the Set Mode Cursor. Available Values: nine patterns ( / Default: 142 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 81: SET MODE FORMAT Function: Selects the display format of the Set Mode operation. Available Values: LIST / ITEM Default: LIST SET MODE ITEM 82: SMART SEARCH Function: Selects the Smart Search Sweep mode. Available Values: SINGLE / CONTINUOUS Default: SINGLE SINGLE: The transceiver sweeps the current band once in each direction starting on the current frequency. All channels where activity is present (up to 15 in each direction) are loaded into the Smart Search memories. Whether or not all 31 memories are filled, the search stops after one sweep in each direction. CONTINUOUS: The transceiver makes a sweep in each direction as with the “SINGLE” mode, but if all 31 channels are not filled after the first sweep, the radio continues sweeping until they are all filled. SET MODE ITEM 83: S-METER SYMBOL Function: Selects the S- & TX PO meter Symbol. Available Values: Four patterns ( Default: , or SET MODE ITEM 84: SPEC-ANALYZER Function: Selects the Spectrum Analyzer sweep mode. Available Values: 1Time / CONTINUOUS / Full Time Default: 1time 1Time: The receiver sweeps the current band once. CONTINUOUS: The receiver sweeps the current band repeatedly until the Spectrum Analyzer is turned off. Full Time: This mode is activated similar to a “Continuous” mode. However, the transceiver outputs audio on the center frequency () through the speaker when Spectrum Analyzer is activated. SET MODE ITEM 85: SQL LEVEL Function: Sets the Squelch threshold level. Available Values: LEVEL 0 ~ LEVEL 15 Default: LEVEL 1 VX-8GR OPERATING MANUAL 143 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 86: SQL S-METER Function: Adjusts the Squelch threshold level to the S-meter level. Available Values: OFF / LEVEL 1 ~ LEVEL 9 Default: OFF SET MODE ITEM 87: SQL SPLIT Function: Enables/Disables split CTCSS/DCS coding. Available Values: OFF / ON Default: OFF When this Set Mode Item is set to “ON”, you can see the following additional parameters after the “MESSAGE” parameter while selecting the Set Mode Item 88: SQL TYPE: D CD: DCS Encode only (“DC” icon will appear while operating) TONE-DCS: Encodes a CTCSS Tone and Decodes a DCS code (the “T-D” icon will appear during operation) D CD-TONE SQL: Encodes a DCS code and Decodes a CTCSS Tone (the “D-T” icon will appear during operation) Select the desired operating mode from the selections shown above. SET MODE ITEM 88: SQL TYPE Function: Selects the Tone Encoder and/or Decoder mode. Available Values: OFF / TONE / TONE SQL / DCS / REV TONE / PR FREQ / PAGER / MESSAGE Default: OFF TONE: Activates the CTCSS Encoder TONE SQL: Activates the CTCSS Encoder/Decoder DCS: Activates the Digital Coded Squelch Encoder/Decoder REV TONE: Activates the Reverse CTCSS Encoder/Decoder (Mutes the receiver when the matching tone is received). PR FREQ: Activates the User Programmed Reverse CTCSS Encoder/Decoder (Mutes the receiver when the matching tone with Set Mode Item 65: PR FREQUENCY is received). PAGER: Activates the Enhanced Paging & Code Squelch. MESSAGE: Activates the Message feature. Note: See also Set Mode Item 87: SQL SPLIT regarding additional selections available during “Split Tone” operation. 144 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 89: STEP FREQUENCY Function: Setting of the DIAL frequency steps. Available Values: AUTO / 5.0 / 6.25 / 8.33 / 10.0 / 12.5 / 15.0 / 20.0 / 25.0 / 50.0 / 100.0 kHz Default: AUTO (Step automatically changes according to operating frequency.) Note: 1) This Set Mode Item can select and set the Dial frequency steps to individual memory channels when Memory Offset Tuning is enabled as shown on page xx. 2) 8.33 kHz steps are available only when receiving on the Air band. 3) 5.0 kHz steps are not available for use on 250 - 300 MHz, nor above 580 MHz. SET MODE ITEM 90: TIME SET Function: Sets the Clock time. See page xx for details. SET MODE ITEM 91: TONE FREQUENCY Function: Setting of the CTCSS Tone Frequency Available Values: 50 standard CTCSS tones Default: 100.0 Hz SET MODE ITEM 92: TONE-SRCH MUTE Function: Enables/Disables the receiver audio output while the Tone Search Scanner is activated. Available Values: ON / OFF Default: ON CTCSS TONE FREQUENCY (Hz) 67.0 69.3 71.9 74.4 77.0 82.5 85.4 88.5 91.5 94.8 79.7 97.4 100.0 103.5 107.2 110.9 114.8 118.8 123.0 127.3 131.8 136.5 141.3 146.2 151.4 156.7 159.8 162.2 165.5 167.9 171.3 173.8 177.3 179.9 183.5 186.2 189.9 192.8 196.6 199.5 203.5 206.5 210.7 218.1 225.7 229.1 233.6 241.8 250.3 254.1 – – – – SET MODE ITEM 93: TONE-SRCH SPEED Function: Selects the Tone Search Scanner speed. Available Values: FAST (2.5 tone/sec) / SLOW (1.25 tone/sec) Default: FAST (2.5 tone/sec) SET MODE ITEM 94: TOT Function: Setting of the TOT time Available Values: OFF / 0.5min - 10.0min (0.5min/step) Default: 3.0min (3 minutes) The time-out timer shuts off the transmitter after a continuous transmission which is equal to the programmed time. VX-8GR OPERATING MANUAL 145 FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SET MODE SELECTION DETAILS SET MODE ITEM 95: VFO MODE Function: Selects or disables the VFO band edge limiting for the current band. Available Values: ALL / BAND Default: BAND ALL: When the VFO frequency reaches the high edge of the current band, the VFO frequency will jump to the low band edge of the next band (or vice versa). BAND: When the VFO frequency reaches the high band edge of the current band, the VFO frequency will jump to the low band edge of the current band (or vice versa). SET MODE ITEM 96: VFO SKIP Function: Set the My Band. Available Values: ON / OFF Default: OFF The “My Band” feature allows you to select several operating bands, and make only those bands available for selection via the B key. ON: Only the bands that are turned on will be shown when pushing the B key. OFF: When the B key is pressed, the bands that are turned “OFF” will not be shown. See page 100 for details. SET MODE ITEM 97: VIBRATOR Function: Enables/Disables the Vibrator function. Available Values: OFF / BUSY / SIGNALIMG Default: OFF OFF: The Vibrator function is disabled. BUSY: The transceiver vibrates when receive a signal. SIGNALIMG: The transceiver vibrates when receive a signal which include the CTCSS, DCS, or EPCS which matches that set into your decoder. SET MODE ITEM 98: VIBRATOR MODE Function: Selects the vibration mode of the Vibrator function. Available Values: MODE1 / MODE2 / MODE3 Default: MODE1 MODE1: The transceiver vibrates continuously. MODE2: The transceiver vibrates at a long interval. MODE3: The transceiver vibrates at a short interval. 146 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SET MODE SELECTION DETAILS SET MODE ITEM 99: VOLUME MODE Function: Select the g key function. Available Values: NORMAL / AUTO BACK Default: NORMAL NORMAL: The g key keeps the status while pressing the g key. AUTO BACK: The g key keeps the status for approximately three seconds after pressing the g key. SET MODE ITEM 100: WX ALERT Function: Enables/disables the Weather Alert Feature Available Values: ON/OFF Default: OFF VX-8GR OPERATING MANUAL 147 FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE SET MODE ITEM 1: APRS DESTINATION 2: APRS FILTER 3: APRS MODEM 4: APRS MSG FLASH 5: APRS MSG TXT 6: APRS MSG VIBRAT 7: APRS MUTE 8: APRS RINGER MSG 9: APRS RINGER BCON 10: APRS UNIT 11: APRS TX DELAY 12: BEACON INTERVAL 13: BEACON STATS TXT 14: BEACON TX 15: COM PORT SETTING 16: DIGI PATH 17: GPS DATUM 18: GPS POWER 19: GPS TIME SET 20: GPS UNIT 21: MSG GROUP 22: MY CALLSIGN 23: MY POSITION 24: MY SYMBOL 25: POSITION COMMENT 26: SmartBeaconing 27: TIME ZONE 148 FUNCTION AVAILABLE VALUES (DEFALT: BOLD ITALIC) Indicates the model code of this transceiver. APY008 (Fixed) Selects the filter type option allowing you to receive the only specified types of APRS Beacon Mic-E: ON / OFF data. POSITION: ON / OFF WEATHER: ON / OFF OBJECT: ON / OFF ITEM: ON / OFF STATUS: ON / OFF OTHER: ON / OFF Enables/Disables the APRS modem (AX25 Data modem) and its Baud Rate. OFF / 1200bps / 9600bps Enables/Disables the white LED light when the APRS message is received. MSG: OFF / 2sec - 10sec (2sec/step) / 20sec / 30sec / 60sec / CONTINUOUS / EVERY 2s - EVERY 10s (10sec/step) / EVERY 1m - EVERY 10m (10min/step) (4sec) GRP: OFF / 2sec - 10sec (2sec/step) / 20sec / 30sec / 60sec / CONTINUOUS (4sec) BLT: OFF / 2sec - 10sec (2sec/step) / 20sec / 30sec / 60sec / CONTINUOUS (4sec) Programming the Fixed form APRS Message. -Selects the Vibration function when receive the APRS Message. MSG: ON / OFF GRP: ON / OFF BLT: ON / OFF Enables/Disables the audio output of the “B-Band” during APRS operation. ON / OFF Enables/Disables the alert ringer when the APRS message is received. MSG: OFF / ON / USER BP1 / USER BP2 / USER BP3 GRP: OFF / ON / USER BP1 / USER BP2 / USER BP3 BLT: OFF / ON / USER BP1 / USER BP2 / USER BP3 Enables/Disables the alert ringer when the APRS beacon is received. ON / OFF Selects the unit for the APRS Beacon information. Position: MM.MM’ / MM’SS” Distance: km / mile Speed: km/h / knot / mph Altitude: m / ft Temp: °C / °F Rain: mm / inch Wind: m / s / mph Select the transmission delay time between transmitting the APRS data and transmitting a 100ms / 150 ms / 200ms / 250ms / 300ms / preamble (flag code) prior to the APRS data. 400ms / 500ms / 750ms / 1000ms Select the Beacon Interval time during APRS operation 30sec / 1min / 2min / 3min / 5min / 10min / 15min / 20min / 30min / 60min Store the message for the APRS Beacon -Enables/Disables the automatic transmission of the APRS Beacon. MANUAL / AUTO / SMART Sets the COM port setting. Sets the APRS packet path you wish to path through. P1 OFF P2 (1) 1 WIDE1 -1 P3 (2) 1 WIDE1 -1, 2 WIDE2 - 1 P4 (2) 1 - - - - - - , 2 - - - - - P5 (2) 1 - - - - - - , 2 - - - - - P6 (2) 1 - - - - - - , 2 - - - - - P7 (2) 1 - - - - - - , 2 - - - - - P8 (8) 1 - - - - - - , 2 - - - - - Select the GPS Datum. WGS-84 / Tokyo Mean / Tokyo Japan / Tokyo Korea / Tokyo Okinawa Enables/Disables the built-in GPS Receiver Unit. GPS ON / GPS OFF Enables/Disables the GPS clock data to be used. AUTO / MANUAL Selects the units for the GPS information. Position: .MMM’ / ‘SS” Speed: km/h / knot / mph Altitude: m / ft Selects the filter type option allowing you to receive only specified types of APRS Message G1 ~ G5, B1 ~ B3 information. (G1: ALL, G2: CQ, G3: QST, G4: YAESU) Program your callsign. -Determine and memorize your location (Lat/Log). GPS / Lat / Lon / P1 ~ P10 Selects your icon which will be displayed on the monitors of other stations as you. more than 180 symbols Selects position comment depending on your situation. Off Duty / En Route / In Service / Returning / Committed / Special / Priority / Custom 0 ~ Custom 6 / EMERGENCY! Sets the SmartBeaconingTM feature. (SmartBeaconingTM from HamHUD Nichetronix) OFF / TYPE1 / TYPE2 / TYPE3 Set the time offset between the local time and UTC. UTC -13:00H ~ UTC +13:00H (0.5H / step) (UTC + 0:00H) VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS SET MODE DETAILS APRS/GPS Set Mode Item 1: APRS DESTINATION Function: Indicates the model code of this transceiver. Default: APY008 This model code can not be changed. APRS/GPS Set Mode Item 2: APRS FILTER Function: Selects the filter type option allowing you to receive only the specified types of APRS Beacon data. Available Values: Mic-E, POSITION, WEATHER, OBJECT, ITEM, STATUS, OTHER Default: Mic-E: ON, POSITION: ON, WEATHER: ON, OBJECT: ON, ITEM: ON, STATUS: ON, OTHER: OFF Mic-E: When this item set to “ON”, the transceiver shows the stations which send a MIC Encoder Beacon. POSITION: When this item set to “ON”, the transceiver shows the stations which send a Position Beacon and Raw NMEA data. WEATHER: When this item set to “ON”, the transceiver shows the stations which send a Weather Beacon. OBJECT: When this item set to “ON”, the transceiver shows the stations which send an Object Beacon. ITEM: When this item set to “ON”, the transceiver shows the stations which send an Item Beacon. STATUS: When this item set to “ON”, the transceiver shows the stations which send a Status Beacon. OTHER: When this item set to “ON”, the transceiver shows the stations which send a packet signal except the APRS beacon. APRS/GPS Set Mode Item 3: APRS MODEM Function: Enables/Disables the APRS modem (AX.25 Data modem) and its Baud Rate. Available Values: OFF / 1200bps / 9600bps Default: OFF VX-8GR OPERATING MANUAL 149 FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS SET MODE DETAILS APRS/GPS Set Mode Item 4: APRS MSG FLASH Function: Selects the interval time of the white LED light function when the APRS message is received. Available Values: MSG: OFF / 2sec - 10sec (2sec/step) / 20sec / 30sec / 60sec / CONTINUOUS / EVERY 2s - EVERY 10s (10sec/step) / EVERY 1m - EVERY 10m (10min/step) SETTING EVERY 2sec - 5sec EVERY 6sec - 9sec EVERY 10sec - 50sec EVERY 1min - 5min EVERY 6min - 10min LED LIGHT Flash one time every setting interval Flash two times every setting interval Flash three times every setting interval Flash four times every setting interval Flash five times every setting interval GRP: OFF / 2sec - 10sec (2sec/step) / 20sec / 30sec / 60sec / CONTINUOUS BLT: OFF / 2sec - 10sec (2sec/step) / 20sec / 30sec / 60sec / CONTINUOUS Default: MSG: 4sec, GRP: 4sec, BLT: 4sec MSG: When receive the message to myself, the white LED light flashes according to the setting of this item. GRP: When receive the group message, the white LED light flashes according to the setting of this item. BLT: When receive the bulletin message, the white LED light flashes according to the setting of this item. APRS/GPS Set Mode Item 5: APRS MSG TXT Function: Programming the Fixed form APRS Message. See page ?? for details. APRS/GPS Set Mode Item 6: APRS MSG VIBRAT Function: Selects the Vibrator function when receive the APRS Message. Available Values: MSG: ON / OFF, GRP: ON / OFF, BLT: ON /OFF Default: MSG: OFF, GRP: OFF, BLT: OFF MSG: When this item set to “ON”, the transceiver vibrates when receive the message to myself. GRP: When this item set to “ON”, the transceiver vibrates when receive the group message. BLT: When this item set to “ON”, the transceiver vibrates when receive the bulletin message. 150 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS SET MODE DETAILS APRS/GPS Set Mode Item 7: APRS MUTE Function: Enables/Disables audio output of the “B-Band” during APRS operation. Available Values: ON/OFF Default: OFF APRS/GPS Set Mode Item 8: APRS RINGER MSG Function: Selects the alert ringer when the APRS message is received. Available Values: MSG: OFF / ON / USR BP1 / USR BP2 / USR BP3 GRP, BLN: OFF / ON / USR BP1 / USR BP2 / USR BP3 Default: MSG: OFF, GRP, BLN: OFF MSG: When receive the message to myself, the alert ringer sounds according to the setting of this item. GRP, BLN: When receive the group or bulletin message, the alert ringer sounds according to the setting of this item. APRS/GPS Set Mode Item 9: APRS RINGER BCON Function: Enables/Disables the alert ringer when the APRS beacon is received. Available Values: ON/OFF Default: ON APRS/GPS Set Mode Item 10: APRS UNIT Function: Selects the unit for the APRS Beacon information. Available Values: Position: MM.MM’/MM’SS”, Distance: km/mile, Speed: km/h/knot/mph, Altitude: m/ft, Temp: °C/°F, Rain: mm/inch, Wind: m/s/mph Default: Position: MM.MM’, Distance: mile, Speed: mph, Altitude: ft, Temp: °F, Rain: inch, Wind: mph APRS/GPS Set Mode Item 11: APRS TX DELAY Function: Select the transmission delay time between transmitting the APRS data and transmitting a preamble (flag code) prior to the APRS data. Available Values: 100ms/150ms/200ms/250ms/300ms/400ms/500ms/750ms/1000ms Default: 300ms PRS/GPS Set Mode Item 12: BEACON INTERVAL Function: Select the Beacon Interval time during APRS operation Available Values: 30sec/1min/2min/3min/5min/10min/15min/20min/30min/60min Default: 5min APRS/GPS Set Mode Item 13: BEACON STATS TXT Function: Store the message for the APRS Beacon See page xx for details. VX-8GR OPERATING MANUAL 151 FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS SET MODE DETAILS APRS/GPS Set Mode Item 14: BEACON TX Function: Enables/Disables the automatic transmission of the APRS Beacon. Available Values: MANUAL/AUTO/SMART Default: MANUAL MANUAL: The VX-8GR does not transmit the APRS beacon automatically. To transmit the APRS beacon, just press the d key. AUTO: The VX-8GR transmits the APRS beacon automatically at the time interval which is set in Set Mode Item 12: BEACON INTERVAL. SMART: The VX-8GR transmits the APRS beacon automatically when the events that are set in Set Mode Item 26: SmartBeaconing occures. APRS/GPS Set Mode Item 15: COM PORT SETTING Function: Sets the COM port setting. Available Values: STATUS: OFF / ON SPEED: 4800 / 9600 / 19200 (bps) INPUT: OFF / GPS OUTPUT: OFF / GPS / WAY.P WAYPOINT: NMEA6 / NMEA7 / NMEA8 / NMEA9 Default: STATUS: OFF, SPEED: 9600, INPUT: OFF, OUTPUT: OFF, WAYPOINT: NMEA9 SPEED: This item selects the baud rate of the COM port which connects the optional packet cable. INPUT: This item selects the type of data input to the COM port. OUTPUT: This item selects the type of data output to the COM port. When this item is set to “OFF”, the transceiver does not output any data from the COM port. When this item is set to “GPS”, the transceiver outputs the GPS data (NMEA data: GGA & RMC) from the COM port. When this item is set to “WAY.P”, the transceiver outputs the Waypoint data from the COM port. APRS/GPS Set Mode Item 16: DIGI PATH Function: Sets the APRS packet path you wish to path through. Available Values: P1 ~ P8 Default: P1: OFF, P2: WIDE1-1, P3: WIDE1-1/WIDE2 -1, P4 ~ P8: non 152 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS SET MODE DETAILS APRS/GPS Set Mode Item 17: GPS DATUM Function: Select the GPS Datum. Available Values: WGS-84/Tokyo Mean/Tokyo Japan/Tokyo Korea/Tokyo Okinawa Default: WGS-84 APRS/GPS Set Mode Item 18: GPS POWER Function: Enables/Disables the built-in GPS Antenna Unit. Available Values: GPS OFF/GPS ON Default: GPS OFF APRS/GPS Set Mode Item 19: GPS TIME SET Function: Enables/Disables the GPS clock data to be used. Available Values: AUTO/MANUAL Default: AUTO APRS/GPS Set Mode Item 20: GPS UNIT Function: Selects the units for GPS information. Available Values: Position: .MMM’/ ‘SS”, Speed: km/h/knot/mph, Altitude: m/ft Default: Position: .MMM’, Speed: mph, Altitude: ft Note: The “Position” item selects the coordinate system. When the “Position” item is set ddd° mm. mmm .MMM’ to “.MMM’ .MMM’”, the VX-8GR displays the location (Lat/Lon) in “ddd° mmm” (Decimal ‘SS” system). When the “Position” item is set to “‘SS” ‘SS””, the VX-8GR displays the location ddd° mm ss (Lat/Lon) in “ddd° ss” (Sexagesimal System). The position information used during APRS operation is used to display the location (Lat/Lon) in Sexagesimal System, regardless of this Set Mode setting. APRS/GPS Set Mode Item 21: MSG GROUP Function: Selects the filter type option allowing you to receive only the specified types of APRS Message information. Available Values: G1 ~ G5, B1 ~ B3 Default: G1: ALL, G2: CQ, G3: QST, G4: YAESU, G5: non, B1 ~ B3: non APRS/GPS Set Mode Item 22: MY CALLSIGN Function: Program your callsign. See page xx for details. VX-8GR OPERATING MANUAL 153 FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS Set Mode Item 23: MY POSITION Function: Determine and memorize your location (Lat/Lon). Available Values: GPS / Lat / Lon / P1 ~ P10 Default: GPS GPS: Your location is determined by the built-in GPS receiver Unit. Lat/Lon: Your location can be entered manually (See page xx for details). P1 ~ P10: Memory Slot for your location (Lat/Lon) as measured with the GPS. To memorize the location: 1. Receive the GPS signal. 2. Recall the APRS/GPS Set Mode Item 23: MY POSITION POSITION. 3. Press the m key briefly to enable adjustment of this Set Mode Item. 1 - 10 4. Rotate the DIAL knob to select the memory slot (1 10) you wish to memorize your location into. 5. Press and hold the h key for one second to memorize your location (Lat/Lon) into the slot. Note: Remember to return this Set Mode Item to “Auto” after you have finished entering your position data into memory. If not then the transceiver always transmits the position data stored in memory and not your true GPS position data. APRS/GPS Set Mode Item 24: MY SYMBOL Function: Select your icon which will be displayed to identify your station on the monitors of other stations. Available Values: ICON1, ICON2, ICON3 (46 symbols each), and ICON4 (free select charactor) Default: ICON1: , ICON2: , ICON3:, USER: You may replace the default icon of the ICON1, ICON2, and ICON3 to another one by rotating the DIAL knob after having pressed the M key. If you wish to change the ICON4 icon, press the M key twice, then rotate the DIAL knob to select the desired Symbol Table ID (left digits in the parenthesis), then press the M key and rotate the DIAL knob to select the desired Symbol Code (right digits in the parenthesis). APRS/GPS Set Mode Item 25: POSITION COMMENT Function: Selects position comment depending on your situation. Available Values: Off Duty, En Route, In Service, Returning, Committed, Special, Priority, Custom 0 ~ Custom 6, EMERGENCY! Default: Off Duty 154 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE APRS/GPS Set Mode Item 26: SmartBeaconing Function: Selects the various parameters of the SmartBeaconingTM. The transceiver transmits the APRS beacon automatically when each parameter value exceeds the set point. Available Values: OFF, TYPE1, TYPE2, or TYPE3 LOW SPEED: 2 ~ 30 mph HIGH SPEED: 3 ~ 70 mph SLOW RATE: 1 min ~ 100 min FAST RATE: 10 sec ~ 180 sec TURN ANGLE: 5° ~ 90° TURN SLOPE: 1 ~ 255 TURN TIME: 5 sec ~ 180 sec Default: TYPE1 (for Vehicle) TYPE2 (for Bicycle) TYEP3 (for Warking) LOW SPD: 5 mph 3 mph 2 mph HIGH SPD: 70 mph 30 mph 12 mph SLOW RATE: 30 min 30 min 30 min FAST RATE: 120 sec 120 sec 120 sec TURN ANGL: 28° 28° 28° TURN SLOP: 26 11 TURN TIME: 30 sec 30 sec 30sec Press the a/b key to select each parameter, then rotate the DIAL knob to set the parameter values. The units of the speed are determined by the transceiver version. SmartBeaconingTM from HamHUD Nichetronix. STATUS: These resisters sum up (combine) the “LOW SPD” through “TURN TIME” items parameters in the “TYPE 1”, “TYPE 2”, or “TYPE 3” settings. When STATUS is set to “TYPE 1”, “TYPE 2”, or “TYPE 3”, the SmartBeaconingTM is activated with parameters of that setting. When STATUS is set to “OFF”, the SmartBeaconingTM function is disabled. LOW SPD: This item designates the lower speed threshold. The VX-8GR transmits an APRS beacon when your movement speed becomes lower than the selected speed. The transmission interval time of the APRS beacon is set in “SLOW RATE” item. The speed unit is determined from the APRS/GPS Set Mode Item 10: APRS UNIT. HIGH SPD: This item designates the higher speed threshold. The VX-8GR transmits an APRS beacon when your movement speed becomes higher than the selected speed. The transmission interval time of the APRS beacon is set in “FAST RATE” item. The speed unit is determined from the APRS/GPS Set Mode Item 10: APRS UNIT. VX-8GR OPERATING MANUAL 155 FCC ID: K6620415X20 / IC:511B-20415X20 APRS/GPS SET MODE SLOW RATE: This item designates the transmission interval time of the APRS beacon at low movement speeds. FAST RATE: This item designates the maximum transmission interval time of the APRS beacon at high movement speeds. TURN ANGL: This item designates the course change angle that indicates a progress heading change. TURN SLOP: This item sets a coefficient to modify the TURN ANGLE algorithm, thus increasing the beacon rate for lower movement speeds. When this setting value is increased, the threshold angles of the APRS beacon timing are increased as the vehicle velocity is decreased. TURN TIME: This item designates the minimum delay time between each APRS beacon. The VX-8GR does not transmit an APRS beacon until this setting time has elapsed since the previous APRS beacon transmission, preventing too frequent beacon transmissions. SmartBeaconingTM from HamHUD Nichetronix. APRS/GPS Set Mode Item 27: TIME ZONE Function: Set the time offset between the local time and UTC. Available Values: UTC -13:00H ~ UTC +13:00H (0.5H/step) Default: UTC +0:00H 156 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 APPENDIX (COMPUTER CONNECTIONS) The VX-8GR allows connecting a computer USB port to the ACC Jack, and enables following functions. Refer to refer to “APRS/GPS Set Mode Item 15: COM PORT SETTING” for the details. Displays the location data (Lat/Lon) of the after-market GPS receiver on the display. Outputs the location data (Lat/Lon) of the built-in GPS receiver unit. Outputs the Waypoint data of the received APRS beacon. Refer to the illustration below, connect the optional CT-143 PC Connection Cable between the USB jack of your Computer and the DATA Jack on the VX-8GR. DATA Jack COM Port CT-143 PC Connection Cable (Option) CT-143 Cable Connections To VX-8GR 2.5-mm 3-pin PLUG TXD (Serial data output: VX-8GR PC) RXD (Serial data input: VX-8GR PC) GND VX-8GR OPERATING MANUAL To PC D-SUB 9-PIN N.C. TXD (Serial data output: VX-8GR PC) RXD (Serial data input: VX-8GR PC) N.C. GND N.C. Connected to pin Connected to pin N.C. 157 FCC ID: K6620415X20 / IC:511B-20415X20 SPECIFICATIONS GENERAL A (Main) Band RX: 108-137 MHz (Air Band) 137-174 MHz (144 MHz HAM) 174-222 MHz (VHF-TV) 222-420 MHz (General 1) 420-470 MHz (430 MHz HAM) 470-800 MHz (UHF-TV, Cellular Blocked) 800-999.90 MHz (General 2, Cellular Blocked) B (Sub) Band RX: 108-137 MHz (Air Band) 137-174 MHz (144 MHz HAM) 174-222 MHz (VHF-TV) 222-420 MHz (General 1) 420-470 MHz (430 MHz HAM) 470-580 MHz (UHF-TV) TX: 144-146 MHz or 144-148 MHz 430-440 MHz or 430-450 MHz Channel Steps: 5/6.25/8.33/10/12.5/15/20/25/50/100 kHz Emission Type: F1D, F2A, F2D, F3E Frequency Stability: ±5 ppm (–10 °C to +60 °C [+14 °F to +140 °F]) Repeater Shift: ±600 kHz (144 MHz), ±1.6/5.0/7.6 MHz (430 MHz) Antenna Impedance: 50 Ohms Supply Voltage: Nominal: 7.4 V DC (Negative Ground) Operating: 4-14 V DC (Negative Ground, EXT DC jack) Operating with Charging: 11-16 V DC (Negative Ground, EXT DC jack) Current Consumption: 200 mA (Mono Band Receive) (@7.4 VDC, approx.) 240 mA (Dual Band Receive) 85 mA (Mono Band Receive, Standby, Saver Off) 120 mA (Dual Band Receive, Standby, Saver Off) 35 mA (Mono Band Receive, Standby, Saver On “Save Ratio 1:5”) 42 mA (Dual Band Receive, Standby, Saver On “Save Ratio 1:5”) 300 μA (Auto Power Off) 1.7A (144 MHz, 5W TX) 1.9 A (430 MHz, 5W TX) Operating Temperature: –20 °C to +60 °C (–4 °F to +140 °F) Case Size (W x H x D): 60 x 95 x 28 mm (2.4” x 3.7” x 1.1”) w/o knob & antenna Weight (Approx.): 250 g (8.8 oz) with FNB-101LI & antenna Frequency Ranges: TRANSMITTER 1.0 W (@4.5 V: AA x 3) 5.0 W (@7.4 V or EXT DC) L3: 2.5 W, L2: 1 W, L1: 0.05 W (@7.4 V) Modulation Type: F2E, F3E: Variable Reactance Maximum Deviation: ±5 kHz (F2E/F3E) Spurious Emission: At least 60 dB below (@ TX power HI/L3/L2) At least 50 dB below (@ TX power L1) Microphone Impedance: 2K Ohms RF Power Output: 158 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 SPECIFICATIONS RECEIVER Circuit Type: IF: Sensitivity: Selectivity: AF Output: Double-Conversion Superheterodyne 1st: 47.25 MHz (A (Main) Band), 46.35 MHz (B (Sub) Band), 2nd: 450 kHz 1.5 μV (TYP) for 10 dB SN (108-137 MHz @AM) 0.2 μV for 12 dB SINAD (137-140 MHz @NFM) 0.16 μV for 12 dB SINAD (140-150 MHz @NFM) 0.2 μV for 12 dB SINAD (150-174 MHz @NFM) 1.0 μV for 12 dB SINAD (174-222 MHz @NFM) 0.5 μV for 12 dB SINAD (300-350 MHz @NFM) 0.2 μV for 12 dB SINAD (350-400 MHz @NFM) 0.18 μV for 12 dB SINAD (400-470 MHz @NFM) 1.5 μV for 12 dB SINAD (470-540 MHz @NFM) 3.0 μV (TYP) for 12 dB SINAD (540-800 MHz @NFM) 1.5 μV (TYP) for 12 dB SINAD (800-999.90 MHz @NFM) (Cellular Blocked) 12 kHz/35 kHz (–6dB/–60dB: NFM, AM) 200 mW @ 8 Ohms for 10 % THD (@ 7.4 V DC) 400 mW @ 8 Ohms for 10 % THD (@ 13.8 V DC) Specifications are subject to change without notice, and are guaranteed within the 144/430 MHz amateur bands only. Cellular Blocked per FCC rule Part 15.121, may not receive 900 MHz Amateur band. VX-8GR OPERATING MANUAL 159 FCC ID: K6620415X20 / IC:511B-20415X20 160 VX-8GR OPERATING MANUAL FCC ID: K6620415X20 / IC:511B-20415X20 1. Changes or modifications to this device not expressly approved by VERTEX STANDARD could void the user’s authorization to operate this device. 2. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference including interference that may cause undesired operation. 3. The scanning receiver in this equipment is incapable of tuning, or readily being altered, by the User to operate within the frequency bands allocated to the Domestic public Cellular Telecommunications Service in Part 22. DECLARATION BY MANUFACTURER The Scanner receiver is not a digital scanner and is incapable of being converted or modified to a digital scanner receiver by any user. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. FCC ID: K6620415X20 / IC:511B-20415X20 Copyright 2010 VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract XMP Toolkit : 3.1-701 Format : application/pdf Title : 紙.pmd Creator : yohtaki Create Date : 2010:03:10 15:18:45+09:00 Creator Tool : PageMaker 7.0J Modify Date : 2010:03:10 16:46:18+09:00 Metadata Date : 2010:03:10 16:46:18+09:00 Producer : Acrobat Distiller 9.3.0 (Windows) Document ID : uuid:dfb9a128-dedb-44c7-8208-fa722c7ec75b Instance ID : uuid:727e88a7-268c-497f-8e78-8bd2edc56603 Has XFA : No Page Count : 164 Author : yohtakiEXIF Metadata provided by EXIF.tools