Yaesu Musen 20523X51 ANALOGUE SCANNING RECEIVER User Manual OM

Yaesu Musen Co., Ltd. ANALOGUE SCANNING RECEIVER OM

User Manual

Download: Yaesu Musen 20523X51 ANALOGUE SCANNING RECEIVER User Manual OM
Mirror Download [FCC.gov]Yaesu Musen 20523X51 ANALOGUE SCANNING RECEIVER User Manual OM
Document ID2926934
Application ID0QmhpPWF8JnySlGUmialvw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize74.14kB (926742 bits)
Date Submitted2016-03-11 00:00:00
Date Available2016-09-07 00:00:00
Creation Date2016-02-01 16:08:46
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2016-02-17 14:01:52
Document TitleOM
Document CreatorAdobe InDesign CS6 (Windows)
Document Author: YAESU MUSEN CO., LTD.

Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Basic Operation
Transmission
1. Press and hold PTT on the microphone.
Both the upper and lower portions of the PTT
mode/status indicator light red.
MIC
DEF
JKL
MNO
PQRS
TUV
WXYZ
P1
LAMP
GHI
ABC
LOCK
MIC
PTT
P3
P4
P2
DTMF MICROPHONE
MH-48
Both the upper and lower portions light red
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
2. Speak into MIC on the microphone.
Note: Keep the microphone about 5 cm away from your mouth.
The sensitivity (gain) of the microphone can be adjusted. For details, refer to the
Advanced Manual (download from the Yaesu website).
3. Release PTT.
The transmit mode/status indicator turns off and the transceiver returns to the receive
mode.
Caution: Do not continue transmitting for a prolonged period. The transceiver may
overheat, resulting in malfunction or injury.
Note: “ERROR” appears if you attempt to transmit on an unavailable frequency.
16
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Basic Operation
Adjusting the transmit power
When communicating with a nearby station, the transmit power level may be lowered to
reduce the battery power consumption.
1. Press the [TXPO] key.
2. Rotate the DIAL to select the transmit power.
Note: The default setting: HIGH
VOL
DIAL
SQL
HIGH (65 W)
MID (30 W)
REV
DW
TXPO
MHz
SETUP
V/M
MW
LOW (5 W)
3. Press the [TXPO] key to save the new setting and exit to normal operation.
Lock Feature
To activate the key-lock feature, press the
[Power(Lock)] key. The “
” icon will appear
on the LCD.
To cancel key-lock, press the [Power(Lock)]
key again.
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
To select which keys are locked, use the Setup Menu Item “17 LOCK” see page 30 for
details.
FTM-3100R Operating Manual
17
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Advanced Operation
Repeater Operation
The FTM-3100R includes the ARS (Automatic Repeater Shift) function, which permits
communication through repeaters automatically, by simply setting the receiver to the repeater frequency.
1. Tune to the repeater frequency.
2. Press the PTT to transmit.
During transmission, radio waves having an 100.0 Hz* tone signal are emitted on the
frequency offset from the receive frequency by 0.6 MHz*.
*: Depends on the transceiver version.
Note: From the Setup Menu, you can change the repeater setting.
RPT ARS 29 à Deactivates the ARS function.
RPT FREQ 30 à Allows changing the repeater shift frequency offset.
RPT SFT 31 à Allows setting the repeater shift direction.
Checking the Repeater Uplink (Input) Frequency
It is often helpful to be able to check the uplink (input) frequency of a repeater, to see if
the calling station is within direct (“Simplex”) range.
Blinks
To do this, just press the [REV(DW)] key. You’ll
notice that the display has shifted to the repeater uplink frequency. Press the [REV(DW)] key
again to cause operation to revert to normal
monitoring of the repeater downlink (output)
frequency. While listening on the repeater input
frequency using the [REV(DW)] key, the repeater offset icon will blink.
18
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Advanced Operation
Weather Broadcast Reception
The FTM-3100R includes a unique feature which allows reception of weather broadcasts
in the 160 MHz frequency range. Ten standard Weather Broadcast channels are preloaded into a special memory bank.
ABC
DEF
GHI
JKL
MNO
PQRS
TUV
WXYZ
P1
LOCK
MIC
PTT
LAMP
To listen to a Weather Broadcast Channel:
1. Press the Microphone [P4] button to recall
the Weather Broadcast channels.
Note: The [P4] key, one of the programmable keys, is assigned (default setting)
as the “WX Broadcast” one-touch
access key. Please note that if you
change/assign another function to the
[P4] key, one-touch access to the WX
channel will be unavailable.
2. Turn the DIAL knob to select the desired
Weather Broadcast channel.
3. To scan the other channels for activity,
press the Microphone PTT switch.
4. To exit to normal operation, press the [P4]
button again. Operation will return to the
VFO or Memory channel in operation before
you began Weather Broadcast operation.
P3
P4
P4 key
P2
DTMF MICROPHONE
MH-48
CH
Frequency
162.550 MHz
162.400 MHz
162.475 MHz
162.425 MHz
162.450 MHz
CH
10
Frequency
162.500 MHz
162.525 MHz
161.650 MHz
161.775 MHz
163.275 MHz
Severe Weather Alert Feature
In the event of extreme weather disturbances, such as storms and hurricanes, NOAA (the
National Oceanic and Atmospheric Administration) sends a weather alert accompanied
by a 1050 Hz tone and subsequent weather report on one of the NOAA weather channels. You may enable this feature via Setup Menu Item “43 WX ALERT” see page 31
for details.
FTM-3100R Operating Manual
19
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Advanced Operation
CTCSS Operation
This radio is equipped with the CTCSS (Continuous Tone-coded Squelch System) that
allows audio to be heard only when receiving signals containing a tone corresponding to
the tone squelch menu setting. By matching the CTCSS tone with the partner station in
advance, quiet standby monitoring is possible.
1. Press and hold the [MHz(SETUP)] key for over one second.
The Setup menu appears.
2. Rotate the DIAL knob to select “SQL TYPE 35”, then press the [MHz(SETUP)] key.
3. Rotate the DIAL knob to select “TSQL”, then
press and hold the [MHz(SETUP)] key for
over one second.
“
” is displayed on the screen. Now the squelch opens only when receiving tone
signals of the set frequency.
Note: From the Setup Menu, you can change the CTCSS setting.
TONE FRQ 38 à The tone frequency can be selected from 50 frequencies.
BELL 6
à A bell tone (beep) may be set to sound when signals containing
a corresponding CTCSS tone are received.
Tone Search
When the CTCSS tone being transmitted by another station is not known, you can tune
the radio to the incoming signal and activate tone scan to search for and identify the tone
being used.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
DCS Operation
This radio is equipped with a DCS (Digital Coded Squelch) function that allows audio to
be heard only when signals containing the corresponding DCS code are received. By
matching the DCS code with the partner stations beforehand, a quiet receive standby is
possible.
1. Press and hold the [MHz(SETUP)] key for over one second.
The Setup menu appears.
2. Rotate the DIAL knob to select “SQL TYPE 35”, then press the [MHz(SETUP)] key.
3. Rotate the DIAL knob to select “DCS”, then
press and hold the [MHz(SETUP)] key for
over one second.
Displays “
” on the screen. The squelch opens only when receiving a signal containing the corresponding DCS code.
20
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Advanced Operation
Note: From the Setup Menu, you can change the DCS setting.
DCS CODE 9 à The DCS code can be selected from 104 codes.
BELL 6
à A bell tone (beep) may be set to sound when signals containing
a corresponding DCS code are received.
DCS Search
When the DCS code being transmitted by another station is not known, you can tune the
radio to the incoming signal and activate DCS code scan to search for and identify the
DCS code being used.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
The following features are also available:
EPCS (Enhanced Paging & Code Squelch) Operation
Use the pager code consisting of two CTCSS tones to exchange communications with
specified stations.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Split Tone Operation
The FTM-3100R can be operated in a “Split Tone” configuration that enables operation on
repeaters using a mix of both CTCSS and DCS control via the Setup menu.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
DTMF Operation
DTMF tones (Dual Tone Multi Frequencies) are the tones you hear when dialing from a
telephone keypad. The FTM-3100R transceiver can transmit the DTMF codes by using
the keys on the microphone or recalling registered number strings from memories.
The maximum of 16-digit DTMF codes can be registered in up to 10 memory channels.
It is convenient to register telephone patch numbers, and network linking sequences to
the DTMF memory channels.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3100R Operating Manual
21
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Memory Operation
The FTM-3100R provides a wide variety of memory system resources. These include:
r 199 “basic” memory channels, numbered “1” through “199”.
r A “Home” channel, providing storage and quick recall of one prime frequency.
r 10 sets of band-edge memories, also known as “Programmable Memory Scan” channels, labeled “L0/U0” through “L9/U9”.
Each memory may be appended with an alphanumeric label of up to 8 characters, for
quick channel recognition.
Memory Storage
1. In the VFO mode, select the desired frequency, repeater shift, CTCSS/DCS tone, and
TX power level.
2. Press and hold the [V/M(MW)] key for one
second.
A memory number will appear in the bottom
right corner of the display.
Note: If the channel number is blinking,
there currently is no data stored on
that channel; if the channel number is
not blinking, that channel is currently
“occupied” by other frequency data.
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
3. Within five seconds of pressing the [V/M(MW)] key, use the DIAL knob to select the
desired memory into which you wish to store the frequency.
Note: While operating in the Memory Storage mode, the keypad of the MH-48A6JA
Microphone may be used to enter the memory channel number directly.
To do this, enter the desired Channel Number on the keypad and then press the
[#] key. Refer to the “For example” of the “Memory Recall from the Microphone
Keypad“ on next page.
4. Press the [V/M(MW)] key again, this time momentarily, to store the displayed data into
the selected memory channel slot.
5. To store additional frequencies, repeat steps 1 through 4, remembering to set the repeater shift, CTCSS/DCS tone, and TX power level, as appropriate.
Split Memory
A separate transmit frequency may be registered to a memory channel to which a receive
frequency has already been registered.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Naming a Memory Channel
You may also append an alphanumeric “Tag” (label) to each memory, to aid in recollection
of the channel’s use (such as club name, etc.).
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
22
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Memory Operation
Memory Recall
Once the desired frequencies are stored into memory channels, switch from the “VFO”
mode to the “Memory Recall” mode, to operate on the just-stored memory channels.
1. Press the [V/M(MW)] key, repeatedly if necessary, until the “
” icon and a memory
channel number appear on the display; this
indicates that the “Memory Recall” mode is
now engaged.
2. When more than one memory has been
stored, use the DIAL knob to select any of
the programmed memories for operation.
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
Note: Alternatively, the microphone [UP] or [DWN] button may be used to step or scan
through the available memories. When using the microphone buttons, press the
button momentarily to move one step up or down; press and hold the [UP] or
[DWN] button for one second to begin memory scanning.
Memory Recall from the Microphone Keypad
While operating in the Memory Recall mode, the keypad of the MH-48A6JA Microphone
may be used for direct recall of memory channels.
To do this, enter the desired Channel Number on the keypad and then press the [#] key.
For example:
To recall Memory Channel “5”, press [5] à [#]
To recall Memory Channel “123”, press [1] à [2] à [3] à [#]
You may also recall Programmable Memory Scan (PMS) channels (“L0/U0” through “L9/
U9”) by entering the channel numbers listed in the below table:
L1
U1
L2
U2
201
202
203
204
L3
U3
L4
U4
205
206
207
208
L5
U5
L6
U6
209
210
211
212
L7
U7
L8
U8
213
214
215
216
L9
U9
L0
U0
217
218
219
220
Moving Memory Data to the VFO
Data stored on memory channels can easily be moved to the VFO.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Memory Only Mode
Once memory channel programming has been completed, you may place the radio in a
“Memory Only” mode, whereby VFO operation is impossible.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3100R Operating Manual
23
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Memory Operation
Masking Memories
There may be situations where you want to “Mask” memories so they are not visible
during memory selection or scanning. (except for Memory Channel “1”, the Priority Channel, and the Home Channel).
1. In the Memory Recall mode, press and hold
the [V/M(MW)] key for one second, then
rotate the DIAL knob to select the memory
channel you wish to mask.
2. Press the [SQL] key.
The erase confirmation screen appears.
3. Press the [SQL] key.
The previously selected memory will be
“masked”.
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
Note: Press any key, other than [SQL], to cancel the memory mask.
Unmasking Memories
1. To Unmask a hidden memory, in the Memory Recall mode, press and hold the
[V/M(MW)] key for one second.
2. Rotate the DIAL knob to select the masked memory number.
3. Press the [SQL] key to restore the memory channel data.
HOME Channel Memory
A convenient one-touch “Home” channel memory is available to simplify returning to an
often used frequency.
To recall the Home channel, just press the
[V/M(MW)] key, repeatedly if necessary, until
the “
” icon appears on the display; this
indicates that the Home Channel has been
recalled.
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
Note: When shipped from the factory, the
Home Channel is set to 146.520 MHz
(USA version) or 144.000 MHz (EXP
version).
Changing the frequency of the home channel
The default frequency setting of the home channel can be changed.
1. In the VFO mode, tune to the desired Home channel frequency.
2. Press and hold the [V/M(MW)] key for one second, and then press the [REV(DW)] key.
The overwrite confirmation screen appears.
3. Press the [REV(DW)] key.
The home channel frequency is overwritten.
24
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Scanning
Basic Scanner Operation
Before activating the scanner, make sure that the Squelch is set to silence the background noise when no signal is present. Scanning is not possible while the Squelch is
open (if noise or signals are being heard).
DWN UP
The following techniques are used for scanning:
r in the VFO mode, press and hold either the [UP]
or [DWN] button for one second, to start upward or
downward scanning of the band.
r In the Memory mode, press and hold either the
[UP] or [DWN] button for one second to start channel scanning toward a higher or lower-numbered
memory channel, respectively.
DEF
GHI
JKL
MNO
PQRS
TUV
WXYZ
P1
LOCK
MIC
ABC
LAMP
Scanning may be started or stopped using the microphone [UP] or [DWN] button.
P3
P4
P2
DTMF MICROPHONE
MH-48
r Scanning pauses when a signal opens the squelch, and the decimal point on the display will blink. You can choose one of three scan-resume modes (described later).
r To halt the scan manually, the easiest way is to push the PTT switch on the microphone
momentarily (no transmission will occur while you are scanning). The scan may also be
halted manually by pressing the microphone [UP] or [DWN] button, or the [V/M(MW)] key.
Scan Resume Options
Select which of the three resume scan modes is to be performed after the scanning stops.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Memory Skip Scanning
Memory channels which you do not want to receive can be skipped during scanning.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Preferential Memory Scan
Set up a “Preferential Scan List” of channels which you can “flag” within the memory system.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Programmable Memory Scan (PMS)
Using the dedicated PMS memory channels, only the frequencies within the specified
frequency range will be scanned.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Priority Channel Scanning (Dual Watch)
Scanning features include a two-channel scanning capability which allows you to operate
on a VFO, Memory channel, or Home channel, while periodically checking a user defined
Memory Channel for activity.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3100R Operating Manual
25
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Reset Procedure/Clone
Reset Procedure
In some instances of erratic or unpredictable operation, the cause may be corruption of
data in the microprocessor (due to static electricity, etc.). If this happens, resetting the
microprocessor may restore normal operation. Note that all memories will be erased if
you do a complete microprocessor reset, as described below.
Microprocessor Resetting
To clear all memories and other settings to factory defaults:
1. Turn the radio OFF.
2. Press and hold the [TXPO], [MHz(SETUP)], and [V/M(MW)] keys while turning the
radio on. The “ALL RESET PUSH V/M KEY” notation will scroll on the display.
3. Press the [D/M(MW)] key momentarily to reset all settings to their factory defaults
(press any other key to cancel the Reset procedure).
Set Mode Resetting
To reset the Set (Menu) mode settings to their factory defaults, while leaving other settings unchanged:
1. Turn the radio OFF.
2. Press and hold the [TXPO] and [MHz(SETUP)] keys while turning the radio on. The
“SET MODE RESET PUSH V/M KEY” notation will scroll on the display.
3. Press the [D/M(MW)] key momentarily to reset the Set (Menu) mode settings to their
factory defaults (press any other key to cancel the Reset procedure).
Clone
The FTM-3100R includes a convenient “Clone” feature, which allows the memory and
configuration data from one transceiver to be transferred to another FTM-3100R.
This can be particularly useful when configuring a number of transceivers for a public
service operation.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
26
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Miscellaneous Settings
Programming the Key Assignments
Default FTM-3100R key functions have been assigned to the Microphone’s [P1]/[P2]/[P3]/
[P4] keys at the factory. The user may change these key function assignments, if quick
access to another function is desired.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Keyboard Beeper
A key/button beeper provides useful audible feedback whenever a key/button is pressed.
If you want to turn the beeper off (or back on again).
Note: If you want to turn the beeper off (or back on again), see Setup Menu Item “3 BEP
KEY” on page 29.
Display Brightness
You can adjust the display brightness.
Note: See Setup Menu Item “16 LCD DMMR” on page 30.
Time-Out-Timer (TOT)
The “Time-Out Timer” (TOT) feature is designed to force the transceiver into the “receive”
mode after a preset time period of continuous transmission (the default is 3 minutes).
Note: See Setup Menu Item “39 TOT” on page 31.
Automatic Power Off (APO)
The “Automatic Power-Off” (APO) feature will turn the radio completely off after a user
defined period of PTT or key/button inactivity.
Note: See Setup Menu Item “1 APO” on page 29.
Busy Channel Lock-Out (BCLO)
The BCLO feature prevents the transmitter from being activated whenever a signal strong
enough to break through the “noise” squelch is present on the frequency.
Note: See Setup Menu Item “2 BCLO” on page 29.
TX Deviation Level
You can reduce the receiver bandwidth and transmit deviation when operating on closely
spaced frequencies (channel spacing of 12.5 or 15 kHz). The reduced transmitter deviation will minimize adjacent channel interference to other users.
Note: See Setup Menu Item “45 W/N DEV” on page 31.
MIC Gain Setting
At the factory, the microphone gain has been programmed so that it should be satisfactory for the supplied MH-48A6JA Microphone. If you use an after-market microphone or
connect a TNC, you may wish to set a different Mic Gain level.
Note: See Setup Menu Item “18 MIC GAIN” on page 30.
FTM-3100R Operating Manual
27
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Miscellaneous Settings
Displaying the Supply Voltage
Display the Power Supply voltage.
Note: See Setup Menu Item “8 DC VOLT” on page 29.
Displaying the Temperature
Indicates the current temperature inside the transceiver’s case.
Note: See Setup Menu Item “37 TEMP” on page 30.
Band Edge Beeper
The FTM-3100R will automatically “beep” when the receiver’s band edge is encountered
during scanning (either in standard VFO scanning or during PMS operation). You may
additionally enable this feature (band edge beeper) when the frequency reaches the band
edge while selecting the VFO frequency manually, using the DIAL knob.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
28
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Setup (Menu) Mode
The FTM-3100R Setup (Menu) mode, already described in parts of many previous
chapters, is easy to activate and set. It may be used for configuration of a wide variety
of transceiver parameters, some of which have not been detailed previously. Use the
following procedure to activate the Setup (Menu) mode:
1. Press and hold the [MHz(SETUP)] key for
one second to enter the Setup menu.
2. Rotate the DIAL knob to select the Menu
Item to be adjusted.
3. Press the [MHz(SETUP)] key momentarily
to enable adjustment of the selected Menu
item, and then rotate the DIAL knob to perform the actual adjustment.
4. After completing your selection and adjustment, press and hold the [MHz(SETUP)] key
for one second to exit the Setup menu and
resume normal operation.
VOL
DIAL
SQL
REV
DW
TXPO
MHz
SETUP
V/M
MW
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Menu Item
Function
Available Values
Default
1: APO
Enables/Disables the Automatic Power
Off feature.
0.5H to 12H (0.5H step)/
OFF
OFF
2: BCLO
Enables/Disables
Lock-Out feature.
ON/OFF
OFF
3: BEP KEY
Enables/Disables the key beeper.
KEY+SCAN/KEY/OFF
4: BEP EDGE
Enables/Disable the Band-edge beeper
while scanning.
ON/OFF
OFF
5: BEP STBY
Enables/Disable the Standby beep
ON/OFF
ON
6: BELL
Selects the CTCSS/DCS/EPCS
Ringer repetitions.
1 to 20/CONTINUE/OFF
OFF
7: CLK TYPE
Shifting of the CPU clock frequency.
8: DC VOLT
Indicates the DC Supply Voltage.
9: DCS CODE
Setting of the DCS code.
104
standard
codes
10: DCS INV
Select a combination of DCS inversion
codes in terms of communication direction.
NORMAL/INVERT/
BOTH
NORMAL
11: DT AUTO
Enables/Disables the DTMF Autodialer
feature.
MANUAL/AUTO
MANUAL
12: DT DELAY
Setting of the DTMF Autodialer TX Delay
Time.
50/250/450/750/1000
13: DT SET
Loading of the DTMF Autodialer Memories.
14: DT SPEED
Setting of the DTMF Autodialer Sending
Speed.
the
FTM-3100R Operating Manual
Busy
Channel
Bell
A/B
---
--50/100
KEY+SCAN
--DCS
023
450 MS
--50 MS
29
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Setup (Menu) Mode
Menu Item
Function
Available Values
Default
15: DW RVRT
Enables/Disables the “Priority Channel
Revert” feature.
ON/OFF
16: LCD DMMR
Setting of the front panel display’s illumination level.
LEVEL 1/2/3/4
17: LOCK
Selects the Control Locking Lockout
combination.
KEY+DIAL/PTT/
KEY+PTT/DIAL+PTT/
ALL/KEY/DIAL
18: MIC GAIN
Adjust the microphone gain level.
LEVEL 1 to 9
19: MEM NAME
Programming an Alpha/Numeric label for
a Memory Channel.
20: MW MODE
Selects the method of selecting of channels for Memory Storage.
NEXT CH/LOWER CH
NEXT CH
21: OPEN MSG
Selects the Opening Message that appears when the radio is powered ON.
OFF/DC/MESSAGE
MESSAGE
22: PAG CD-R
Setting the Receiver Pager Code for
the Enhanced CTCSS Paging & Code
Squelch function.
---
05 47
23: PAG CD-T
Setting the Transmitting Pager Code for
the Enhanced CTCSS Paging & Code
Squelch function.
---
05 47
24: PRG P1
Programming the function assigned to
Microphone’s [P1] key.
25: PRG P2
Programming the function assigned to
Microphone’s [P2] key.
26: PRG P3
Programming the function assigned to
Microphone’s [P3] key.
27: PRG P4
Programming the function assigned to
Microphone’s [P4] key.
28: RF SQL
Adjusts the RF Squelch threshold level.
OFF/S1 to S8
OFF
29: RPT ARS
Activates/Deactivates the Automatic Repeater Shift feature.
ON/OFF
ON
30: RPT FREQ
Sets the magnitude of the Repeater Shift.
0.00 - 150.00 (MHz)
0.60 MHz
31: RPT SFT
Sets the Repeater Shift direction.
-RPT/+RPT/SIMPLEX
SIMPLEX
OFF
---
SQL OFF
HOME
WX CH
CD SRCH
SCAN
T CALL
TX POWER
DIG/ANA
GM
Setup Menu Item #1 to
45
LEVEL 4
KEY+DIAL
LEVEL 5
---
SQL OFF
HOME
CD SRCH
ø
32: SCAN RSM
Selects the Scan Resume mode.
BUSY/HOLD/2-10 (SEC)
33: SCAN SKP
Selects the Memory Scan mode.
OFF/SKIP/SELECT
OFF
34: SQL EXP
Sets the squelch type separately for
transmission and reception.
ON/OFF
OFF
35: SQL TYPE
Selects the Tone Encoder and/or Decoder mode.
TONE/TSQL/DCS/
RV TONE/PAGER/OFF
OFF
36: STEP
Sets the Synthesizer steps.
AUTO/5/6.25/10/12.5/15
/20/25/50/100 (kHz)
AUTO
37: TEMP
Indicates the current temperature inside
the transceiver’s case.
---
ø
38: TONE FRQ
Setting of the CTCSS Tone Frequency.
30
67.0 to 254.1 (Hz)
5.0 SEC
100.0 HZ
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Setup (Menu) Mode
Menu Item
Function
Available Values
Default
39: TOT
Sets the Time-Out Timer.
0.5 to 10.0 (MIN)/OFF
40: TS MUTE
Enables/Disables the receiver audio output while the Tone Search Scanner is
activated.
ON/OFF
41: TS SPEED
Selects the Tone Search Scanner speed.
FAST/SLOW
42: VER DISP
Displays the transceiver software version
CPU x.xx
DSP x.xx
---
43: WX ALERT
Enables/Disables the Weather Alert feature.
ON/OFF
OFF
44: WX VOL
Selects the audio output level of the
Weather Alert.
NOR VOL/MAX VOL
45: W/N DEV
Reduction of the Microphone Gain/Deviation and receiver bandwidth.
WIDE/NARROW
3.0 MIN
ON
FAST
NOR VOL
WIDE
ø: Depends on the transceiver version.
FTM-3100R Operating Manual
31
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Maintenance
Care and maintenance
Turn the power OFF before wiping away any dust and stains on the transceiver with a dry
soft cloth. For stubborn stains, slightly moisten a soft cloth and wring it out before using it
to wipe away the stains.
Caution: Never use washing detergents and organic solvents (thinner, benzene, etc.).
Doing so may result in paint flaking or damage to the transceiver finish.
Replacing the fuse
When the fuse of the DC power supply cable blows and the transceiver becomes
inoperable, correct the cause of the problem, and then replace the fuse with a new one of
the correct (25 Amp) rating.
Caution: When replacing the fuse, be sure to disconnect the power supply cable from
the transceiver and from the external DC power supply.
Replacing the fuse of the DC power supply cable
1. Prepare a new fuse.
Use a fuse with a rating of 25 A.
Caution: Never attempt to use a fuse that is
not of the specified rating
2. Open the fuse holder as shown in the diagram on the right.
3. Remove the blown fuse.
4. Attach the new fuse.
5. Close the fuse holder.
32
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Specifications
General
Frequency Range:
Tx 144 - 148 MHz
Rx 136 - 174 MHz
Channel Step:
5/6.25/10/12.5/15/20/25/50/100 kHz
Standard Repeater Shift:
±600 kHz
±10 ppm [-4 °F to +140 °F (-20 °C to +60 °C)]
Frequency Stability:
Modes of Emission:
F3E
Antenna Impedance:
50 Ohms, unbalanced
Supply voltage:
13.8 V DC ±15%, negative ground
Current Consumption (typical): Rx: less than 0.7 A, less than 0.5 A (squelched)
Tx: 15 A (65 W) /10 A (30 W) /5 A (5 W)
Operating Temperature Range: -4° F to +140° F (-20° C to +60° C)
Case Size (WxHxD):
6.1” x 1.7” x 6.1” (154 x 43 x 155 mm) (w/o knobs)
Weight (Approx.):
2.86 lb (1.3 kg)
Transmitter
Output Power:
Modulation Type:
Maximum Deviation:
Spurious Radiation:
Microphone Impedance:
65/30/5 W
Variable Reactance
±5 kHz (Wide)
±2.5 kHz (Narrow)
Better than -60 dB
2k Ohms
Receiver
Circuit Type:
Ifs:
Sensitivity (for 12dB SINAD):
Selectivity (–6/–60dB):
Maximum AF Output:
Double Conversion Superheterodyne
1st 47.25 MHz, 2nd 450 kHz
0.20 μV (Ham band, wide)
0.22 μV (Ham band, narrow)
12 kHz/28 kHz
3 W @ 13.8 V, 10% THD
Rated values are at normal temperature and pressure.
Ratings and specifications are subject to change without notice.
FTM-3100R Operating Manual
33
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
1. Changes or modifications to this device that are not expressly approved by YAESU MUSEN could
void the user’s authorization to operate this device.
2. This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference including received, interference that may cause undesired operation.
3. The scanning receiver in this equipment is incapable of tuning, or readily being altered, by the User
to operate within the frequency bands allocated to the Domestic public Cellular Telecommunications
Service in Part 22.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit
pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
DECLARATION BY MANUFACTURER
The Scanner receiver is not a digital scanner and is incapable of being converted or modified to a
digital scanner receiver by any user.
WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE
SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW.
CAN ICES-3 (B) / NMB-3 (B)
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
r Reorient or relocate the receiving antenna.
r Increase the separation between the equipment and receiver.
r Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
r Consult the dealer or an experienced radio/TV technician for help.
34
FTM-3100R Operating Manual
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
Application for FCC / IC
FCC ID: K6620523X51 / IC: 511B-20523X51
YAESU MUSEN CO., LTD.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo 140-0002 Japan
Copyright 2016
YAESU MUSEN CO., LTD.
All rights reserved.
No portion of this manual
may be reproduced
without the permission of
YAESU MUSEN CO., LTD.
Printed in Japan
1602-0O
YAESU USA
6125 Phyllis Drive, Cypress, CA 90630, U.S.A.
YAESU UK
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
*EH052N150*

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : YAESU MUSEN CO., LTD.
Create Date                     : 2016:02:01 16:08:46+09:00
Modify Date                     : 2016:02:17 14:01:52+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2016:02:17 14:01:52+09:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:898042ff-18f8-4e19-abcf-e3ecfae0066b
Original Document ID            : xmp.did:7DF23E1DD389E511907BB1A157F41809
Document ID                     : xmp.id:1ABBC695B2C8E5119183F005C201A778
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:19BBC695B2C8E5119183F005C201A778
Derived From Document ID        : xmp.did:3EEFF4418BB2E511815A939E47A59CF3
Derived From Original Document ID: xmp.did:7DF23E1DD389E511907BB1A157F41809
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:02:01 16:08:46+09:00
Format                          : application/pdf
Title                           : OM
Creator                         : YAESU MUSEN CO., LTD.
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 21
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K6620523X51

Navigation menu