Yaesu Musen 30593X3D MOBILE MARINE TRANSCEIVER User Manual GX6000 Owner s Manual
Yaesu Musen Co., Ltd. MOBILE MARINE TRANSCEIVER GX6000 Owner s Manual
Contents
OM User Manual 6
4. Press the [YES] soft key to transmit the polling call. 5. After a polling call is transmitted, if the reply signal is not received, “Waiting for ACK” is shown on the display which means the GX6000 is waiting for the vessel you called to send an acknowledgement. 6. To transmit the call again, press the [RESEND] soft key. 7. Press the [QUIT] soft key to return to radio operation. Polling Call by Manually Entering an MMSI This feature allows you to contact a vessel by manually entering the MMSI of the ship you want to track. 1. ] “DSC CALL” “POLLING CALL” 2. Rotate the DIAL/ENT knob to select “MANUAL”, then press the [SELECT] soft key. 3. Rotate the DIAL/ENT knob to select the first number in the MMSI and press the [SELECT] soft key. 4. Repeat step 3 until all the digits of the MMSI are shown on the display. 5. If a mistake was made entering in the MMSI number, rotate the DIAL/ENT knob to select “←” or “→”, press the [SELECT] soft key until the wrong character is selected, then perform step 3. 6. When finished entering the MMSI number, press the [FINISH] soft key. 7. Press the [YES] soft key to transmit the polling call. 8. Press the [QUIT] soft key to return to radio operation. Page 76 GX6000 10.8.2 Receiving a Polling Call When another vessel transmits a polling call to the GX6000 the following will happen: 1. When a polling call is received, the radio will automatically respond to the calling vessel. 2. To exit from the polling call display, press the [QUIT] soft key. 10.9 AUTO POSITION POLLING The GX6000 has the capability to automatically track seven vessels programmed into the individual directory, or to automatically send your position information to the programmed stations. 10.9.1 1. Setting up the Polling Operation ] “SETUP” “DSC SETUP” “AUTO POSITION POLLING” 2. Rotate the DIAL/ENT knob to select the desired operation (AUTO POS REQUEST and AUTO POS REPORT), and press the [ENTER] soft key. 3. Press the CLEAR key to return to radio operation. 10.9.2 1. Setting up the Polling Time Interval ] “SETUP” “DSC SETUP” “AUTO POS INTERVAL” 2. Rotate the DIAL/ENT knob to select “AUTO POS INTERVAL”, then press the [SELECT] soft key. 3. Rotate the DIAL/ENT knob to select the desired interval time (30 second, 1, 2, 3, and 5 minutes) and press the [ENTER] soft key. 4. Press the CLEAR key to return to radio operation. GX6000 Page 77 10.9.3 Selecting Vessels to be Automatically Polled NOTE The radio uses the individual directory to select vessels to be automatically polled. Refer to section “10.4.1 Setting up the Individual / Position Call Directory” and to enter MMSI of vessels you want to poll before proceeding. 1. ] “DSC CALL” “AUTO POS POLLING” 2. Rotate the DIAL/ENT knob to select “SELECTED ID”, then press the [SELECT] soft key. 3. The radio will show a blank row highlighted when you select the vessel for the first time. Press the [SELECT] soft key. 4. The radio will show the vessels programmed in the individual directory. Rotate the DIAL/ENT knob to select the desired vessel, then press the [ENTER] soft key. 5. For more entries, rotate the DIAL/ENT knob to select a blank row, press the [SELECT] soft key, then perform step 4. 6. When finished, press the CLEAR key to exit to the radio mode. 10.9.4 1. Enabling/Disabling Auto POS Polling ] “DSC CALL” “AUTO POS POLLING” 2. Rotate the DIAL/ENT knob to select the “ACTIVATION”, then press the [SELECT] soft key. 3. Rotate the DIAL/ENT knob to select “START” to enable transmissions or “STOP” to disable, then press the [ENTER] soft key. Page 78 GX6000 4. Press the CLEAR key to return to radio operation. 5. Auto POS Polling starts and “[A]” icon will light up on the screen. 10.10 DSC TEST This function is used to contact another DSC equipped vessel to ensure the DSC functions of the radio are operating. NOTE To use this feature, the radio that will receive the test call also needs to have the DSC Test feature. To perform the DSC test you will need to enter the MMSI of another vessel into the individual directory or manually enter in the MMSI using the procedure below. 10.10.1 Programming MMSI into Individual Directory Refer to section “10.4.1 Setting up the Individual / Position Call Directory”. 10.10.2 Transmitting a DSC Test to Another Vessel DSC Test call by using Individual/Position Directory 1. ] “DSC CALL” “DSC TEST CALL” 2. Rotate the DIAL/ENT knob to select “HISTORY” or “MEMORY”, then press the [SELECT] soft key. 3. Rotate the DIAL/ENT knob to select the ship name, then press the [SELECT] soft key. 4. Press the [YES] soft key to transmit the DSC test call to the other vessel. 5. Press the [QUIT] soft key to return to radio operation. GX6000 Page 79 DSC Test Call by Manually Entering an MMSI 1. ] “DSC CALL” “DSC TEST CALL” “MANUAL” 2. Rotate the DIAL/ENT knob to select “MANUAL”, then press the [SELECT] soft key. 3. Rotate the DIAL/ENT knob to select the first digit in the MMSI, then press the [SELECT] soft key. 4. Repeat step 3 until all the numbers of the MMSI are shown on the display. 5. Press the [FINISH] soft key to show the test call page. 6. Press the [YES] soft key to transmit the DSC test call to the other vessel. 7. Press the [QUIT] soft key to return to radio operation. NOTE After the radio receives a test call reply from the vessel that was called, the radio will ring and show “RX TEST CALL” display, which confirms the radio you called has received the test call. 10.10.3 Receiving a DSC Test Call When another vessel transmits a DSC Test call to the GX6000 the following will happen: 1. When a DSC Test call is received, the radio will automatically respond to the calling vessel. 2. To exit from the DSC Test call display, press the [QUIT] soft key. Page 80 GX6000 10.11 DSC LOG OPERATION The GX6000 logs transmitted calls, received DSC distress calls, and other calls (individual, group, all ships, etc.). The DSC log feature is similar to an answer machine where calls are recorded for review and a “ ” icon will appear on the radio's display. The GX6000 can store up to 100 transmitted calls, up to the latest 50 distress calls, and up to the latest 100 other calls (individual, group, all ships, position report, position request ack, test call ack, and polling calls). NOTE When the “DSC LOG” menu is selected, the GX6000 may display high-priority logged call automatically. 10.11.1 Reviewing and Resending a Transmitted Logged Call The GX6000 allows transmitted logged calls to be reviewed and to resend the call. 1. ] “DSC CALL” “DSC LOG” 2. Rotate the DIAL/ENT knob to select “TRANSMITTED”, then press the [SELECT] soft key. 3. Rotate the DIAL/ENT knob to select the station (name or MMSI number) you want to review and/or resend the call. 4. Press the [SELECT] soft key to review details for the selected station. 5. Depending on the type of the DSC LOG selected in step 5, you can check the information of the LOG by pressing the [INFO] soft key and can reply by pressing the [CALL] soft key. GX6000 Page 81 10.11.2 Reviewing a Logged DSC RX Distress Call The GX6000 allows logged DSC RX distress call to be reviewed. 1. ] “DSC CALL” “DSC LOG” “RX DISTRESS” 2. Rotate the DIAL/ENT knob to select the station (name or MMSI number) you want to review and/or relay the distress call to other vessels. Note: When there is an unread received call, “ ” icon will appear to the left of the logged call. 3. Press the [SELECT] soft key to review details for the selected station. 4. Press the [INFO] soft key to display more information or press the [BACK] soft key to go back to the received DSC distress call list. 10.11.3 Reviewing Other Logged Calls 1. ] “DSC CALL” “DSC LOG” “RX OTHER CALL” 2. Rotate the DIAL/ENT knob to select the station (name or MMSI number) you want to review and/or call back. Note: When there is an unread received call, “ ” icon will appear to the left of the logged call. 3. Press the [SELECT] soft key to review details for the selected station. 4. Press the [REPLY] soft key to reply to the call or press the [BACK] soft key to go back to the received call list. 10.11.4 Deleting Logged Calls from the DSC Log Directory 1. Page 82 ] “DSC CALL” “DSC LOG” “LOG DELETE” GX6000 2. Rotate the DIAL/ENT knob to select the category (“TRANSMITTED”, “RX DISTRESS”, “RX OTHER CALL” or “ALL LOG”) to be deleted. 3. Press the [SELECT] soft key. The display will show “Do you want to delete the LOG?”. 4. Press the [YES] soft key. (To cancel, press the [NO] soft key.) 5. Press the CLEAR key to return to radio operation. NOTE The procedure above will delete all logged calls of the selected category at one time. To delete logged calls one by one, review the details of the call you want to delete, then press the [DELETE] soft key. 10.12 DSC LOOP BACK OPERATION The GX6000 has a self-test feature for DSC call. 1. ] “DSC CALL” “DSC LOOP BACK” 2. Press the [YES] soft key to start a test. (To cancel, press the [NO] soft key.) The display will show “Passed!” if the DSC feature properly operates, then press the [OK] soft key to the “DSC CALL” menu. 3. Press the CLEAR key to return to radio operation. GX6000 Page 83
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : YAESU MUSEN CO., LTD. Create Date : 2017:04:20 08:38:24+09:00 Modify Date : 2017:04:20 08:39:49+09:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2017:04:20 08:39:49+09:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Title : GX6000 Owner's Manual Creator : YAESU MUSEN CO., LTD. Document ID : uuid:c04d269d-6507-4efc-9f88-1c618e0954f9 Instance ID : uuid:158349b9-ce00-498f-bee8-286ab3f9708c Producer : Adobe PDF Library 10.0.1 Page Count : 8EXIF Metadata provided by EXIF.tools