Yaesu Musen VR-5000 User Manual VR 5000 OperatingManual

Yaesu Musen Co., Ltd. VR 5000 OperatingManual

Contents

Manual

Download: Yaesu Musen VR-5000 User Manual         VR 5000 OperatingManual
Mirror Download [FCC.gov]Yaesu Musen VR-5000 User Manual         VR 5000 OperatingManual
Document ID105056
Application ID/uvIXLGEha/DZ8fY+4NOdw==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.61kB (95083 bits)
Date Submitted2000-06-15 00:00:00
Date Available2000-09-26 00:00:00
Creation Date2000-06-01 17:50:12
Producing SoftwareAcrobat PDFWriter 4.0 Windows
Document Lastmod0000-00-00 00:00:00
Document Titleæ©¡VR-5000_OperatingManual.PDF
Document Creatoræ©¡Microsoft Word
Document Author: æ©¡USER090

VR-5000
Operating Manual
Front Panel Controls & Switches
(1) MAIN VOL/SQL Knob
MAIN VOL Knob
The inner MAIN VOL knob adjusts the audio volume of the MAIN receiver in the
speaker or headphones.
SQL Knob
The outer SQL knob sets the signal level threshold at which MAIN receiver audio is
muted (and the “BUSY” icon in the LCD turns off), in all mode. This is normally
kept fully counter clockwise, except when scanning and during FM operation.
(2) SUB VOL/TONE Knob
SUB VOL Knob
This inner SUB VOL knob adjusts the audio volume of the SUB receiver in the
speaker or headphones.
TONE Knob
The outer TONE knob adjusts receiver audio characteristics.
(3) PHONES Jack
This 3-pin (“stereo”) miniature jack is used for connection to your headphones.
When a plug is inserted into this jack, the internal (or external) speaker will be cut
off.
This jack’s impedance is optimized for use with 16Ω to 32 Ω headphone type.
(4) PWR Knob
This is a main on/off switch for the VR-5000. Press and hold this switch for one
second to toggle the receiver’s power on and off.
(5) LCD (Liquid Crystal Display)
The upper half of the display consists of dot-matrix display for frequency readout
and various icons representing enabled receiver features.
The lower half contains a dot-matrix display for Band Scope viewing, menu
programming, and alpha numeric name display etc.
(6) Functions Keys
[M/S(SUB SET)] Key
Press this key momentarily, to toggle the operating VFO between MAIN VFO and
VR-5000
Operating Manual
SUB VFO.
Press this key after [F] key is pressed, to toggle the VFO link feature on and off.
[BS(BS SET)] Key
Press this key momentarily, to toggle the Band Scope feature on and off.
Press this key after [F] key is pressed when the Band Scope is activated, activate
the SUB VFO cursor which enable the SUB VFO tuning.
[WIDTH(BS STEP)] Key
Press this key momentarily, to select the Band Scope sweep width.
Press this key after [F] key is pressed when the Band Scope is activated, select the
Band Scope sweeping step.
[SCAN(M-S SCAN)] Key
Press this key momentarily, to activate the scanning.
Press this key after [F] key is pressed, to activate the M-S Scanning.
M-S Scan: The scanner activates between the MAIN VFO frequency and SUB VFO
frequency.
[PMS(PMS SET)] Key
Press this key momentarily, to activate the Programmable Memory Scan.
Press this key after [F] key is pressed, to enable the PMS memory programming.
[CLR(PRI CLR)] Key
Press this key momentarily,
Press this key after [F] key is pressed, to disable the Priority.
[V(DIM)] Key
Press this key momentarily, to enable the display brightness setting.
Press this key after [F] key is pressed, activates the optional FVS-1A Voice
Synthesizer Unit which provides announcement of the operating frequency (with
resolution to the displayed 100 Hz digit) for operators with vision impairments.
(7) PS Key
Press this key momentarily, to recalls the one of up to five PS (PreSet) memories for
operation.
Press and hold this key for one second, to store the operating parameters into
consecutive PS memories.
(8) Command Keys
[MODE(ADRS)] Key
Press this key momentarily, to select the operating (receiving) mode.
VR-5000
Operating Manual
Press this key after [F] key is pressed, to select the recording field for the voice
recorder (required the optional FVS-1A Voice Synthesize Unit)
[COPY(REC)] Key
Press this key momentarily, copy the SUB VFO data into the MAIN VFO.
Press this key after [F] key is pressed, to start the voice recorder.
[STEP(PLAY)] Key
Press this key momentarily, to select the synthesizer steps to be used during VFO
operation.
Press this key after [F] key is pressed, to playback the voice recorder.
[V/M(MW)] Key
Press this key momentarily, to change the frequency control between the VFO and
the Memory system.
Press this key after [F] key is pressed, to store the frequency into memory.
[BANK] Key
Press this key momentarily, to select the memory bank.
(9) τ(θ)/υ(π) Keys
In the VFO mode, pressing either of these keys momentarily step (according to the
DIAL knob’s step) the operating frequency down or up respectively. Pressing either
of these keys after [F] key is pressed, steps down or up 10 MHz.
In the Memory mode, pressing either of these keys momentarily step the Memory
Channel down or up respectively.
While the Band Scope is engaged, pressing either of these keys to move the
Channel Marker.
(10) Keypad
This keypad is used for direct frequency entry during VFO operation.
Secondary functions allow to control the VR-5000’s various features.
(11) [F] Key
This key is used to activate the “Alternate” command functions of the panel keys.
If this key is pressed before one of the panel keys is pressed, the “Alternate”
functions of the key will be enabled.
(12) DSP Key
Press this key momentarily, activate the optional DSP-1 Digital Signal Processing
VR-5000
Operating Manual
Unit.
(13) DIAL Knob
This is the main tuning dial for the VR-5000. It is used for most tuning memory
selection, and function setting tasks on the VR-5000.
Rear Panel Connections
(1) DC 13.5V Jack
This is the DC power supply connection for the VR-5000. Connect the Supplied PA4A AC adapter to this jack.
(2) MUTE Jack
If using the VR-5000 with a transceiver, shorting this jack during transmit will
mute receiver output and attenuate RF signal input. Check with information
provided with your particular transceiver for proper connection.
(3) ANT B Terminal
Use these spring-loaded terminal connectors to connect a high-impedance antenna.
(4) ANT Switch
This switch selects antenna connected from either the ANT A jack or ANT B
terminal.
(5) ANT A Jack
Connect the 50 Ω coaxial feed line to your low-impedance antenna here using a
type-M (PL-259) connector.
(6) EXT SP Jack
This 2-contact mini phone jack provides receiver audio for an external loudspeaker
with an impedance of 4 ~ 16 Ω. Inserting a plug in this jack disables the
loudspeaker.
(7) REC Jack
This jack provides a constant level (??? mV @ ? Ω) audio output, which is unaffected
by the VOL and TONE controls. This audio can be used for recording purposes, and
VR-5000
Operating Manual
for connection to data demodulator/decoder equipment.
(8) +8V Jack
This output jack provides 8V DC at up to ??? mA for low power accessories. The
center contact is positive.
(9) IF OUT Jack
This output jack provides low-level (0.1 Vrms (-6 dBm) @ 50 Ω) 10.7 MHz IF output.
(10) CAT Jack
This 9-pin serial DB-9 jack allows external computer control of the VR-5000.
Connect a serial cable here and to the RS-232C COM port on your personal
computer.
Basic Operation
Turning the Power on/off
Press and hold the orange PWR switch for one second to turn the radio on and off.
Adjusting the Volume and Squelch
1.
Rotate the MAIN VOL knob to adjust the audio volume of the MAIN VFO. Rotate
the SUB VOL knob to adjust the audio volume of the SUB VFO. Clockwise rotation
of these VOL knobs increases the volume level. Both VOL knobs can be rotated to
adjust the relative balance of receiver audio between the two VFO during dual
reception.
2.
The VR-5000 squelch system allows you to mute the receiver’s audio output when
no signals are being received. To set the squelch, turn the SQL knob fully counter
clockwise, then turn it clockwise just past the point where the background noise is
silenced. Do not rotate the SQL knob much beyond this threshold point; if you do,
the receiver will not respond to weal signals.
3.
Rotate the TONE knob to adjust the receiver audio characteristics. Clockwise
rotation of the TONE knob emphasize the high-frequency component. The TONE
knob effects to the MAIN and SUB VFO audio.
Frequency Navigation
Tuning DIAL
VR-5000
Operating Manual
Rotating the DIAL knob allows tuning in the pre-programmed steps established for the
current receiving band. Clockwise rotation of the DIAL knob causes the VR-5000 to be
turned toward a higher frequency, while counter clockwise rotation will lower the
receiving frequency.
If you press the [F] key momentarily, then rotate the DIAL knob, frequency steps of 1
MHz will be selected. This feature is extremely useful for making rapid frequency
excursions over the wide turning range of the VR-5000.
UP(π)/DOWN(θ) Tuning
Pressing the [τ(θ)/υ(π)] keys allows tuning in the pre-programmed steps established for
the current receiving band. Pressing the [υ(π)] key causes the VR-5000 to be turned
toward a higher frequency, while Pressing the [τ(θ)] key will lower the receiving
frequency.
If you press the [F] key momentarily, then press the [τ(θ)/υ(π)] keys, frequency steps of
10 MHz will be selected. This feature is extremely useful for making rapid frequency
excursions over the wide turning range of the VR-5000.
Direct Keypad Frequency Entry
The desired receiving frequency may be entered directly from the keypad.
The receiving mode will automatically be set once the new frequency is entered via the
keypad.
To enter a frequency from the keypad:
1. Enter the “MHz” portion of the frequency on which you wish to receive.
2. Enter the decimal point after the “MHz” portion by pressing the [•(BEEP)] key.
3. Enter five more digits to complete the frequency.
4. If there are “zeros” at the end of the frequency, you may press the [ENT(SET)] key
after the final non-zero digit.
Examples:
To enter 146.16250 MHz, press [1] à [4] à[6] à[•] à[1] à[6] à[2] à[5] à[0]
To enter 950 kHz, press [•] à[9] à[5] à[0] à[0] à[0]
To enter 445.40000 MHz, press [4] à [4] à[5] à[•] à[4] à[ENT]
MODE Selection
The VR-5000 automatically selects a default receiving mode according to the frequency
band on which you are receiving. However, many bands (especially HF Short-wave) may
use a variety of transmission modes in a particular frequency segment.
If you want a change the receiving mode, press the [MODE(ADRS)] key. The receiving
modes available are:
VR-5000
Operating Manual
LSB à USB à CW à AM-N à AM à WAM à FM-N à WFM à AUTO à LSB à
USB ……
Dual Receive
The VR-5000 provides the two VFOs (MAIN VFO and SUB VFO) which operate the
Dual Receive feature. However, the SUB VFO set only ±20 MHz bandwidth of the MAIN
VFO frequency. For example: The MAIN VFO is set to 1280.000 MHz, the SUB VFO can
be set to 1260.000 ~ 1300.000 MHz. Also, the SUB VFO set only AM or FM-N modes.
Press the [M/S(SUB SET)] key momentarily, to toggle the operating VFO between
the MAIN VFO and SUB VFO.
When turning the MAIN VFO frequency, the SUB VFO frequency tracks the MAIN
VFO (VFO Tracking feature).
To disable the VFO Tracking feature, press the [M/S(SUB SET)] key after [F] key is
pressed. Repeat the same procedure to enable the VFO Tracking feature again.
When you are in the SUB VFO, press the [CLR(PRI CLR)] key after [F] key is
pressed to disable the SUB VFO temporarily. Repeat the same procedure to activate
the SUB VFO again.
When you are in the MAIN VFO, press the [CLR(PRI CLR)] key after [F] key is
pressed to disable the SUB VFO. However, in this case, press the [M/S(SUB SET)]
key to activate the SUB VFO.
Press the [COPY(REC)] key to copy the SUB VFO data to the MAIN VFO.
Adjusting the clock
1.
Press the [F] key momentarily, then press the [ENT] key.
2.
Rotate the DIAL knob to select the cursor to the “MISC” menu, then press the [ENT]
key.
3.
Rotate the DIAL knob to select the cursor to the “CLOCK” menu, then press the
[ENT] key.
4.
Enter the present time via the keypad.
Example 1: Set to 9:38, Press [0] à [9] à [3] à [8].
Example 2: Set to 13:20, Press [1] à [3] à [2] à [0].
5.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the [ENT]
key.
6.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT] key.
7.
Adjusting the clock is now completely.
VR-5000
Operating Manual
Receiving the World Broadcast Stations
1.
Press the [F] key momentarily, then press the [4(SPL)] key.
2.
Rotate the DIAL knob to select the cursor to the “STATION CALL” menu, then press
the [ENT] key to recall the representation World Broadcast Station (refer to the
following list). Blink the small dot on the world atlas which means the
(approximately) location of its Broadcast Station.
3.
Press the [BANK] key to select the desired Broadcast Station.
4.
Rotate the DIAL knob or press the [τ(θ)/υ(π)] keys to select the Broadcast Station’s
frequency.
5.
To disable the World Broadcast Station Receiving, press the [CLR(PRI CLR)] key,
then press the [ENT] key.
World Broadcast Stations List
Bank Display
Station’s Name
Frequency (MHz)
01
VOA
Voice Of America
6.030/6.160/9.760/11.930
02
R-CANADA
Radio Canada International
5.995/7.235/9.735/11.705
03
R-PORTUG
Radio Portugal
9.780/11.960/15.555/21.655
04
SPAIN
Radio Exterior de Espana
7.270/9.520/11.920/15.585
05
BBC
British Broadcasting Corporation
6.195/9.410/12.095/15.310
06
R-FRANCE
Radio France International
6.045/9.790/11.670/15.525
07
BELGIUM
Radio Vlaanderen International
5.985/9.925/13.74/11.780
08
R-NEDERL
Radio Nederland
5.955/6.020/9.620/11.655
09
R-LUXEMB
Radio Luxembourg
6.090
10
D-WELLE
Deutsche Welle
6.075/9.545/9.735
11
SWISS-R
Swiss Radio International
3.985/6.165/9.885/15.220
12
R-NORWAY
Radio Norway International
7.485/9.590/9.985/13.800
13
ITARY
Italian Radio International (RAI)
6.060/7.175/9.515/17.710
14
R-DENMAR Radio Denmark
9.590/9.985/13.800/15.735
15
R-SWEDEN
Radio Sweden
6.065/9.490/13.625/17.600
16
R-FINLAN
Radio Finland
6.120/9.560/11.755/21.670
17
ISRAEL
Israel Broadcasting Authority
9.435/11.585/15.340/17.535
18
RUSSIA
Voice of Russia
5.905/5.920/7.205/12.030
19
INDIA
All India Radio (AIR)
7.410/9.595/11.620/15.020
20
CHINA-R
China Radio International (CRI)
7.190/9.535/9.855/11.945
21
R-KOREA
Radio Korea
5.795/7.275/5.970/13.670
22
R-JAPAN
Radio Japan
6.145/6.180/9.750/11.850
VR-5000
Operating Manual
23
R-AUSTRA
Radio Australia
5.995/9.680/12.080/15.415
Memory Operation
The VR-5000 provides a wide variety of memory system resources. These include:
r 2000 main memory channels into 100 memory groups.
r 50 sets of band-edge memories also known as “Programmable Memory Scan”
channels.
r Five PS (PreSet) memory channels, providing one-touch storage and recall of
prime receiving frequencies.
Main Memory System
Memory Storage
1.
Select the desired frequency, while receiving on the MAIN VFO. Be sure to set up
any desired features described later, if you wish to store them.
2.
Press the [F] key momentarily, then press the [V/M(MW)] key to enable the memory
storage.
3.
To designate the memory group, proceed to the next step; otherwise press the
[COPY(REC)] key twice to save the entry and exit to the VFO mode.
4.
Confirm that the cursor is on the “Channel” menu, then press the [ENT] key.
5.
Press the [τ(θ)/υ(π)] keys to select the desired memory group to be stored, then press
the [ENT] key.
6.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the [ENT]
key.
7.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT] key to save
the entry and exit to the VFO mode.
Memory Recall
1.
While operating the VFO mode, press the [V/M(MW)] key to switch to the memory
mode.
2.
Press the [τ(θ)/υ(π)] keys to select the desired memory group or press the desired
memory group number from the keypad, then rotate the DIAL knob to select the
desired memory channel.
3.
To return to the VFO mode, press the [V/M(MW)] key again.
You can recall the all memories by only rotating the DIAL knob (Memory Bank less). To
VR-5000
Operating Manual
do this:
(1) Press the [F] key momentarily, then press the [ENT(SET)] key.
(2) Rotate the DIAL knob to select the cursor to the “MR” menu, then press the
[ENT] key.
(3) Confirm the cursor is on the “MR BANK” menu, then press the [•(BEEP)] key to
change its setting to “All Mem.”
(4) Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT] key.
(5) Confirm that the cursor is on the “WRITE” menu, then press the [ENT] key to
save the entry and exit.
If you select the “MR BANK” menu to “In BANK” in step (3), retune the selecting
method to select the memory group by [τ(θ)/υ(π)] keys and select the memory
channel by the DIAL knob.
Enhanced Memory Channel Operation
Memory Offset Tuning
Once you have recalled a particular memory channel, you may easily tune off that
channel, as through you were in the “VFO” mode.
1.
With the VR-5000 in the “ MR” (Memory Recall) mode, select the desired memory
channel.
2.
Press the [BS(BS SET)MT] key momentarily.
3.
Rotate the DIAL knob or press the [τ(θ)/υ(π)] keys, as desired, to tune a new
frequency.
4.
If you wish to return to the original memory frequency, press the [V/M(MW)] key
momentarily.
5.
Press the [COPY(REC)] key to return to the VFO with a new frequency set during
Memory Tuning.
Naming Memories
You may wish to append an alpha-numeric “Tag” (label) to a memory or memories, to aid
in recollection of the channel’s use (such as the Broadcasting station name, etc.).
1.
Recall the memory channel on which you wish to append a label.
2.
Press the [F] key momentarily, then press the [V/M(MW)] key.
3.
Rotate the DIAL knob to select the cursor to “CH TAG” menu, then press the
[ENT(SET)] key to enable the programming of the name tag to the memory.
4.
Press the keypad to select the first digit of the desired label, according to the key
10
VR-5000
Operating Manual
entered rule described below. When you have made your selection, rotate the DIAL
knob clockwise one click to move to the next character.
5.
Repeat the previous step to program the remaining letters, numbers, or symbols of
the desired label. A total of 74 characters may be used in the creation of label.
6.
When you have complete the creation of the label, press the [ENT(SET)] key.
7.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
8.
Confirm that the cursor is on the “WRITE” menu, press the [ENT] key.
9.
The memory naming is now completely.
Keypad Sequence
r Press the [1(ATT)] key repeatedly to toggle between the two available characters:
“1” à “Space” à “1” ……
r Press the [2(LOCK)] key repeatedly to toggle among the seven available characters:
“2” à “A” à “B” à “C” à “a” à “b” à “c” à “2” à “A” ……
r Press the [3(S.SCH)] key repeatedly to toggle among the seven available characters:
“3” à “D” à “E” à “F” à “d” à “e” à “f” à “3” à “D” ……
r Press the [4(SPL)] key repeatedly to toggle among the seven available characters:
“4” à “G” à “H” à “I” à “ g” à “h” à “i” à “4” à “G” ……
r Press the [5(PRI)] key repeatedly to toggle among the seven available characters:
“5” à “J” à “K” à “L” à “ j à “k” à “l” à “5” à “K” ……
r Press the [6(S.CALL)] key repeatedly to toggle among the seven available characters:
“5” à “M” à “N” à “O” à “m” à “n” à “o” à “6” à “ M” ……
r Press the [7(VCS)] key repeatedly to toggle among the seven available characters:
“7” à “P” à “Q” à “R” à “p” à “q” à “r” à “7” à “P” ……
r Press the [8(RF TUNE)] key repeatedly to toggle among the seven available
characters:
“8” à “S” à “T” à “U” à “s” à “t” à “u” à “8” à “S” ……
r Press the [9(TIMER)] key repeatedly to toggle among the seven available characters:
“9” à “V” à “W” à “X” à “v” à “w” à “x” à “9” à “ V” ……
r Press the [0(NB)] key repeatedly to toggle among the five available characters:
“0” à “Y” à “Z” à “y” à “ z” à “0” à “Y” ……
r Press the [DSP] key repeatedly to toggle among the 11 available symbols:
“!” à “ ” ” à “$” à “%” à “ &” à “ ’ ” à “(” à “)” à “*” à “ +” à “ :” à “ !” ……
r Press the [BS] key to delete the character before the cursor.
r Press the [τ(θ)] key to move the cursor to the left.
11
VR-5000
Operating Manual
r Press the [υ(π)] key to move the cursor to the right.
r Press the [CLR(PRI CLR)] key to cancel the creation of the label.
r Press the [CLR(PRI CLR)] key after [F] key is pressed, to cancel the all characters.
Naming Memory Groups
1.
Press the [V/M(MW)] key, if needed, to enter the “MR” (Memory Recall) mode.
2.
Recall the memory group on which you wish to append a label, then press the
[BANK] key.
3.
Confirm that the cursor is on the “BANK TAG” menu, press the [ENT(SET)] key.
4.
Program the alpha-numeric “label” which you wish to recall using the DIAL knob
and keypad, as described previously.
5.
When you have complete the creation of the label, press the [ENT(SET)] key.
6.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
7.
Confirm that the cursor is on the “WRITE” menu, press the [ENT(SET)] key.
8.
The memory group naming is now completely.
Protecting Memory (Inhibit the Edit)
You may wish to “Protect” a certain Memory Channel’s data to prevent accidental data
change.
To Protect a channel’s data:
1.
Recall the Memory Channel to be protected.
2.
Press the [F] key momentarily, then press the [V/M(MW)] key.
3.
Rotate the DIAL knob to select the cursor to “END” menu, then press the
[ENT(SET)] key.
4.
Rotate the DIAL knob to select the cursor to “PROTECT” menu, then press the
[•(BEEP)] key to change its setting to “PROTECT.”
5.
Rotate the DIAL knob to select the cursor to “WRITE” menu, then press the
[ENT(SET)] key to protect the channel’s data.
If you select the “PROTECT” menu to “FREE” in step 4, disable the memory protect
feature.
Masking Memory
You may wish to “Mask” a certain Memory Channel’s data, when you no longer have a
reason to recall that channel.
To Mask a channel’s data:
12
VR-5000
Operating Manual
1.
Recall the Memory Channel to be masked.
2.
Press the [F] key momentarily, then press the [V/M(MW)] key.
3.
Rotate the DIAL knob to select the cursor to “Channel” menu, then press the
[ENT(SET)] key.
4.
Press the [F] key momentarily, then press the [CLR(PRI CLR)] key.
5.
Confirm that the cursor is on the “DELETE” menu, then press the [ENT(SET)] key.
6.
Press the [CLR(PRI CLR)] key.
7.
Confirm that the cursor is on the “CANCEL” menu, then press the [ENT(SET)] key
to mask the channel’s data.
To unmask a channel’s data:
1.
Press the [F] key momentarily, then press the [V/M(MW)] key.
2.
Rotate the DIAL knob to select the cursor to “Channel” menu, then press the
[ENT(SET)] key.
3.
Select the masked memory using the [τ(θ)/υ(π)] keys and DIAL knob. The masked
memory appears “n” icon in the lower left corner of the LCD.
4.
Press the [F] key momentarily, then press the [CLR(PRI CLR)] key.
5.
Rotate the DIAL knob to select the cursor to “OLD READ” menu, then press the
[ENT(SET)] key.
6.
Rotate the DIAL knob to select the cursor to “END” menu, then press the
[ENT(SET)] key.
7.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key to
unmask the channel.
Alpha-Numeric Memory Recall
You can use the VR-5000’s powerful microprocessor system to search for Memory
Channels according to their alpha-numeric label. In the example below, we shall set up
the VR-5000 to find all channels programmed with “POLICE” as an alpha-numeric label
(e.g. POLICE 1, POLICE 2, etc.).
1.
Press the [V/M(MW)] key, if needed, to enter the “MR” (Memory Recall) mode.
2.
Press the [WIDTH(BS STEP)] key to enable setup of Alpha-Numeric Memory Recall.
3.
Program the alpha-numeric “label” which you wish to recall using the DIAL knob
and keypad, as described previously. In this case, program “POLICE” as the label.
4.
Press the [M/S(SUB SET)SORT] key, recall the memory channel beginning with
“POLICE.”
5.
Press the [M/S(SUB SET)SORT] key, you will observe that only channels beginning
with “POLICE” are appearing on the display.
13
VR-5000
Operating Manual
6.
When you find the desired memory channel, press the [ENT(SET)] key to be
recalled.
Important Note: You can recall Memory Channels alpha-numerically using just one or
tow letters of a label within above steps. In the above example, if you programmed “PO”
instead of “POLICE,” you could then recall channels such as “PONTIAC,” “PORTER,”
“PORTLAND,” and “POWER” in addition to “POLICE.” But if you set “POR,” only
“PORTER” and PORTLAND” would be recalled.
PS (PreSet) Memory Channels
A convenient PS memories are desired for the favorite channel (such as the local
broadcast station) where very simple storage and recall procedures are desired.
PS Memory Channel Storage
1.
Tune the radio to the desired frequency.
2.
Press and hold the [PS] key for one second.
3.
Press the [PS] key to select the PS channel which you wish to store the current
frequency data.
4.
Press and hold the [PS] key for one second, to enable the programming of the name
tag to the PS memory. To attach an alpha/numeric name to the PS memory, proceed
the programming of the name tag previously; otherwise press the [ENT(SET)] key
again.
5.
Press the [ENT(SET)] key to finish the PS Memory Channel storage.
PS Memory Channel Recall
1.
Press the [PS] key to recall the currently active PS Memory Channel.
2.
Press the [PS] key repeatedly to cycle through the PS Memory Channels.
3.
Rotate the DIAL knob to exit the PS memory Channel and return to VFO mode.
Scanning
The VR-5000 allows you to scan just memory channels, the entire operating band, or a
portion of that band. It will halt on signals encountered, so you can hear the station(s)
on that frequency, if you like.
Scanning operation is basically the same in each of the above modes. Before you begin,
take a moment to select the way in which you would like the scanner to stop scanning
for halts on a signal and resume scanning after it halts on a signal.
14
VR-5000
Operating Manual
Setting the Scan-Stop Technique
Three options for the Scan-Stop mode are available:
NORMAL: In this mode, the scanner will stop on a signal it encounters.
TONE: In this mode, the scanner will stop when the radio detects the correct CTCSS
tone.
TONE: In this mode, the scanner will stop on a signal matching a prescribed CTCSS
tone will open the squelch.
S-METER: In this mode, the scanner will stop on a signal exceeding a prescribed Smeter level will open the squelch.
VOICE: In this mode, the scanner will stop on a signal with a voice signal.
VOICE: In this mode, the scanner will stop on a signal which have a voice signal.
Setting the Scan-Resume Technique
Three options for the Scan-Resume mode are available:
DELAY: In this mode, the scanner will halt on a signal it encounters, and will hold until
the signal disappears. Two after the squelch closes, scanner resumes automatically
PAUSE: In this mode, the scanner will halt on a signal it encounters. 2 seconds after the
carrier has dropped because the other station(s) ceased transmission, the scanner will
resume. In the case of constant-carrier signals like Weather Station broadcasts, the
scanner will likely remain on this frequency indefinitely.
HOLD: In this mode, the scanner will halt on a signal it encounters. It will not restart
automatically; you must manually re-initiate scanning if you wish to resume.
Here is the procedure for setting up the Scan-Resume mode:
1.
Press the [F] key momentarily, then press the [ENT(SET)] key.
2.
Confirm that the cursor is on the “VFO” menu, then press the [ENT(SET)] key.
3.
If you set the Scan-Resume mode for the MAIN VFO, rotate the Confirm that the
cursor is on the “MainScan” menu.
4.
Press the [•(BEEP)] key to select the desired Scan-Resume mode among the
“DELAY,” “PAUSE,” and “ HOLD.”
5.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
6.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key to
save a new setting and exit the Set mode.
15
VR-5000
Operating Manual
VFO Scanning
1.
Press the [V/M(MW)] key to recall the VFO mode, if needed.
2.
Press the [SCAN(M-S SCAN)] key to initiate scanning in an upward direction.
3.
If the scanner encounters a signal strong enough to open the squelch, the scanner
will halt and pause on that frequency.
4.
To reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), turn the DIAL knob one click in the counter-clock direction or
press the [τ(θ)] key momentarily while the VR-5000 is scanning. To revert to
scanning toward a higher frequency once more, rotate the DIAL knob one click
clockwise or press the [υ(π)] key momentarily.
5.
Press the [V/M(MW)] key to disable the scanner.
Programmable (Band Limit) Memory Scan (PMS)
This feature allows you to sub-band limits scanning.
Programming
1.
Press the [F] key momentarily, then press the [PMS(PMS SET)] key to enable the
storing the frequency pair into the PMS memory.
2.
Rotate the DIAL knob to select the cursor to the “PMS TAG” menu.
3.
Press the [ENT(SET)] key to enable the programming of the name tag to the PMS
memory. To attach an alpha/numeric name to the PMS memory, program the
alpha-numeric “label” using the DIAL knob and keypad, as described previously;
otherwise press the [ENT(SET)] key again.
4.
When you have complete the creation of the label, press the [ENT(SET)] key.
5.
Rotate the DIAL knob to select the cursor to the “START F” menu, then press the
[ENT(SET)] key.
6.
Select the VFO frequency to the Low sub-band limit, then press the [ENT(SET)] key.
7.
Confirm that the cursor is on the “END F” menu, press the [ENT] key.
8.
Select the VFO frequency to the Upper sub-band limit, then press the [ENT(SET)]
key.
9.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
10. Confirm that the cursor is on the “WRITE” menu, press the [ENT] key.
11. The PMS memory programming is now completely.
Note: 50 PMS memories are available. You therefore can set upper and lower operation
limits on a number of bands, if you like.
16
VR-5000
Operating Manual
Operation
1.
Press the [PMS(PMS SET)] key to initiate PMS scanning in an upward direction.
2.
If the scanner encounters a signal strong enough to open the squelch, the scanner
will halt and pause on that frequency.
3.
To reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), turn the DIAL knob one click in the counter-clock direction or
press the [τ(θ)] key momentarily while the VR-5000 is scanning. To revert to
scanning toward a higher frequency once more, rotate the DIAL knob one click
clockwise or press the [υ(π)] key momentarily.
4.
Press the [V/M(MW)] key to disable the PMS scanner, and return to VFO mode.
Adjusting the PMS scanner
1.
Press the [F] key momentarily, then press the [PMS(PMS SET)] key.
2.
Rotate the DIAL knob to select the cursor to the “MISC” menu, then press the
[ENT(SET)] key.
3.
Rotate the DIAL knob to select the cursor to the desired menu from the following
list to be you wish adjusting.
ScanStop: Select the Scan Resume mode among “HOLD,” “DELAY,” and “PAUSE”
via pressing the [•(BEEP)] key.
(1) In the “HOLD” mode, when a signal is received the scanner will hold for 2
second, then the scanner will stop.
(2) In the “DELAY” mode, when a signal is received the scanner will hold until the
signal disappears, then the scanner will resume after 2 seconds.
(3) In the “PAUSE” mode, when a signal is received the scanner will hold for 2
second, then scanner will resume after 2 seconds.
S-LvlScan: The scanner will halt and pause on the frequency when the is a signal
strong enough to stops on
VCS: Enable/disable the VCS (Voice Channel Scan) feature via pressing the
[•(BEEP)] key. When enable the VCS feature enabled, the scanner will only halt
and pause on the frequency that is having the voice signal.
ATT: Enable/disable the RF signal Attenuator via pressing the [•(BEEP)] key.
RF-TUNE: Enable/disable the RF-TUNE circuit via pressing the [•(BEEP)] key.
SKIP:
DSP:
M-DCS:
17
VR-5000
Operating Manual
M-CTCSS:
LINK:
4.
5.
M-S Scan
This feature allows you to sub-band limits scanning between the MAIN VFO frequency
and SUB VFO frequency.
1.
Press the [V/M(MW)] key to recall the VFO mode, if necessary.
2.
Press the [F] key momentarily, then press the [SCAN(M-S SCAN)] key to initiate
scanning in an upward direction between the MAIN VFO frequency and SUB VFO
frequency.
3.
If the scanner encounters a signal strong enough to open the squelch, the scanner
will halt and pause on that frequency.
4.
To reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), turn the DIAL knob one click in the counter-clock direction or
press the [τ(θ)] key momentarily while the VR-5000 is scanning. To revert to
scanning toward a higher frequency once more, rotate the DIAL knob one click
clockwise or press the [υ(π)] key momentarily.
5.
Press the [SCAN(M-S SCAN)] key to disable the M-S Scan, and return to the VFO
mode.
Memory Scanning
1.
Press the [V/M(MW)] key, if needed, to enter the “MR” (Memory Recall) mode.
2.
Press the [τ(θ)/υ(π)] keys to select the memory bank on which you wish to memory
channel scanning.
3.
Press the [SCAN(M-S SCAN)] key to initiate memory channel scanning in an
upward direction in the current memory bank.
4.
If the scanner encounters a signal strong enough to open the squelch, the scanner
will halt and pause on that channel.
5.
To reverse the direction of the scan (i.e. toward a lower memory channel, instead of
a higher memory channel), turn the DIAL knob one click in the counter-clock
direction or press the [τ(θ)] key momentarily while the VR-5000 is scanning. To
revert to scanning toward a higher memory channel once more, rotate the DIAL
knob one click clockwise or press the [υ(π)] key momentarily.
6.
Press the [SCAN(M-S SCAN)] key to disable the memory channel scanner.
18
VR-5000
Operating Manual
If you wish to memory channel scanner activates the all memories in the all memory
bank;
(1) Press the [F] key momentarily, then press the [ENT(SET)] key.
(2) Rotate the DIAL knob to select the cursor to the “MR” menu, then press the
[ENT(SET)] key.
(3) Confirm the cursor is on the “MR BANK” menu, then press the [•(BEEP)] key to
change its setting to “All Mem.”
(4) Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT] key.
(5) Confirm that the cursor is on the “WRITE” menu, then press the [ENT] key to
save the entry and exit.
(6) Press the [SCAN(M-S SCAN)] key to initiate memory channel scanning in an
upward direction on the all memories in the all memory bank.
If you select the “MR BANK” menu to “In BANK” in step (3), retune the memory
channel scanner to activates the current memory bank only.
Memory Channel Skip
As mentioned previously, some continuous-carrier stations like a Broadcast station will
serious impede scanner operation if you are using the “PAUSE” Scan-resume mode, as
the incoming signal will not pause long enough for the receiver to resume scanning.
Such channel may be “skipped” during scanning, if you like.
1.
Recall the Memory Channel to be skipped during scanning.
2.
Press the [CLR(PRI CLR)] key. The “SKIP” icon appears in place of the “SEL” icon.
To cancel the memory channel skip, repeat the above steps to appears “SEL” icon in
place of “SKIP” icon.
Band Scope Operation
The Band Scope allows viewing of operating activity on channels above or below the
current operating channel in the VFO mode.
The display will indicate the relative signal strengths of signals on channels
immediately adjacent to the current operating frequency. A convenient “Channel
marker” can be used to zero in on one of the stations displayed; when you turn off the
Band Scope, the VR-5000 will be set to the frequency set by the Channel Marker.
19
VR-5000
Operating Manual
To activate the Band Scope
1.
Set the radio to the VFO mode by pressing the [V/M(MW)] key, if necessary.
2.
Press the [BS(BS SET)] key momentarily to activate the Band Scope.
3.
When the Band Scope is activated, rotate the DIAL knob or press the [τ(θ)/υ(π)] keys
to move the Channel Marker.
4.
When the Band Scope is activated, you can change the Sweep steps. may be
adjusted by the front panel keys. To do this, press the [F] key momentarily, then
press the [WIDTH(BS STEP)] key to select the sweep step as follows:
5.
MODE
Steps
LSB/USB/CW
1.0 kHz (fixed)
AM-N/AM
1.0/5.0/9.0/10.0/20.0/25.0/50.0 kHz
WAM
1.0/5.0/9.0/10.0/20.0/25.0/50.0/100.0 kHz
FM-N
5.0/6.25/10.0/12.5/20.0/25.0/50.0/100 kHz
WFM
10.0/50.0/100/500 kHz
The Sweep range is can be changes as well. To do this, press the [WIDTH(BS STEP)]
key to select the sweep step as follows:
MODE
Sweep range
LSB/USB/CW
100/300/500 kHz
AM-N/AM
0.1/0.2/0.3/0.5/1.0/2.0/2.5/5.0/10.0 MHz
WAM /FM-N
0.5/1.0/2.0/2.5/5.0/10.0 MHz
WFM
1.0/2.0/5.0/10.0 MHz
6.
Smart Search Operation
The Smart Search feature allows you to load frequencies automatically according to
where activity is encountered by your radio.
To set up Smart Search operation:
1.
Press the [F] key momentarily, then press the [ENT(SET)] key.
2.
Rotate the DIAL knob to select the cursor to the “PMS” menu, then press the
[ENT(SET)] key.
3.
Confirm that the cursor is on the “S.SCH Bank” menu, then press the [ENT(SET)]
key.
4.
Rotate the DIAL knob to select the memory bank which you wish to store the active
frequencies, then press the [ENT(SET)] key.
5.
Confirm that the cursor is on the “S.SCH Full” menu, press the [•(BEEP)] key to
select the desired Smart Search mode between the “FIFO” and “STOP,” then press
20
VR-5000
Operating Manual
the [ENT(SET)] key.
“FIFO”:
“STOP”: The Smart Search stops when the memory bank is full.
1.
Priority Operation
The priority feature, which is somewhat similar to Dual Watch, allow you to monitor a
memory channel while checking a “Priority Memory” channel every five seconds for
activity. If the Priority Memory channel becomes active with a signal strong enough to
open the Squelch, the radio will halt on that frequency and will hold there in accordance
with the setting of the “RESUME” mode described previously.
To setup the Priority Monitoring:
1.
Press the [F] key momentarily, then press the [V/M(MW)] key.
2.
Rotate the DIAL knob to select the cursor to the “Channel” menu, then press the
[ENT(SET)] key.
3.
Press the [F] key momentarily, then press the [5(PRI)] key. A “PRIυ” icon appears on
left of the memory channel number in the LCD. Then press the [ENT(SET)] key.
4.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
5.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
To initiate the Priority:
Press the [F] key momentarily, then press the [5(PRI)] key to initiate the Priority.
To disable the priority, repeat the above step.
The VR-5000 can be changes the checking time (five seconds) among. To do this:
1.
Press the [F] key momentarily, then press the [ENT(SET)] key.
2.
Rotate the DIAL knob to select the cursor to the “MISC” menu, then press the
[ENT(SET)] key.
3.
Rotate the DIAL knob to select the cursor to the “PRI WATCH” menu, then press the
[ENT(SET)] key.
4.
Rotate the DIAL knob to select the checking time among “1 sec,” “2 sec,” “5 sec,” and
“10 sec,” then press the [ENT(SET)] key.
5.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
21
VR-5000
Operating Manual
6.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
World Clock
The VR-5000 has a World Clock on the 66 areas.
1.
Press the [F]key momentarily, then press the press the [4(SPL)] key.
2.
Confirm that the cursor is on the “WORLD TIME” menu, then press the [ENT(SET)]
key. Appear the World Clock and the World Atlas.
3.
Rotate the DIAL knob to select the desired area.
4.
Press the [•(BEEP)] key, display the World Clock to Summer Time, if current area
has a Summer Time system. Press the [•(BEEP)] key again to return to normal.
5.
To disable the World Clock, press the [CLR(PMS CLR)] key then press the
[ENT(SET)] key.
You can change the area name to be desired name (i.e. “LOS ANGL” change to
“Cerritos”). To do this:
1.
Recall the area which you wish change the area name, as descried previously.
2.
Press the [ENT(SET)] key to enable the programming of the area name.
3.
Program the area mane (max 8 characters) using the DIAL knob and keypad, as
descried previously then press the [ENT(SET)] key. In this case “Cerritos.”
4.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
Timer Operation
On/Off Timer
The On/Off timer can be automatically turn on and off at present time. This is
convenient if you want to tape record a broadcast while you are out.
Programming:
1.
Press the [F] key momentarily then press the [9(TIMER)] key.
2.
Rotate the DIAL knob to select the cursor to the “TM PROG.” Menu, then press the
[ENT(SET)] key.
3.
Press [ENT(SET)] key again to enable the programming the On/Off timer.
4.
Rotate the DIAL knob to adjust the time you want the radio to turn on, then press
the [ENT(SET)] key.
5.
Rotate the DIAL knob to adjust the time you want the radio to turn off, then press
the [ENT(SET)] key.
6.
If you attach an alpha/numeric name to the On/Off timer, program the alpha-
22
VR-5000
Operating Manual
numeric “label” using the DIAL knob and keypad, as described previously;
otherwise press the [CLR(PRI CLR)] key.
7.
Rotate the DIAL knob to select the cursor to the “WRITE” menu, then press the
[ENT(SET)] key.
Operation:
1.
Press the [F] key momentarily then press the [9(TIMER)] key.
2.
Rotate the DIAL knob to select the cursor to the “TM PROG.” Menu, then press the
[ENT(SET)] key to select to “ON” which enable the On/Off timer.
3.
Rotate the DIAL knob to select the cursor to the “TM PROG.” Menu, then press the
[ENT(SET)] key.
If you disable the On/Off timer, select the TM PROG.” Menu to “OFF” in step 2.
When activate the On/OFF Timer, appear the “PROG” icon above the MAIN frequency
display in the LCD.
Sleep Timer
The Sleep Timer can be automatically turn off the radio. This is convenient if you want
to doze off listening to the radio.
1.
Press the [F] key momentarily then press the [9(TIMER)] key.
2.
Rotate the DIAL knob to select the cursor to the “APO” Menu, then press the
[ENT(SET)] key to enable the programming of the Sleep Timer.
3.
Rotate the DIAL knob to select the desired sleep time among “30 min,” “60 min,” “90
min,” “120 min,” and “OFF,” then press the [ENT(SET)] key.
4.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
5.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
When activate the Sleep Timer, appear the “SLEEP” icon above the MAIN frequency
display in the LCD.
Alarm Timer
The Alarm Timer can be automatically turn on the radio. This is convenient if you wake
up to your favorite station (or beep sound) every morning.
1.
Press the [F] key momentarily then press the [9(TIMER)] key.
2.
Rotate the DIAL knob to select the cursor to the “ALARM” Menu, then press the
[ENT(SET)] key to enable the programming of the Alarm Timer.
3.
Press the key to select the Alarm sound between the “Radio” or “Beep,” then press
23
VR-5000
Operating Manual
the [ENT(SET)] key.
4.
Enter the time you want the radio turn on using the keypad, as descried previously,
then press the [ENT(SET)] key.
5.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
6.
Confirm that the cursor is on the “WRITE” menu, then press the [ENT(SET)] key.
When activate the Alarm Timer, appear the “ON” icon above the MAIN frequency
display in the LCD.
Miscellaneous Operations
ATT (RF Attenuator)
For situations where extremely high signal levels are present, the receiver’s input
ATTenuator may be activated, to reduce the sensitivity and total gain of the receiver
system.
1.
To activate the Attenuator, press the [F] key momentarily, then press the [1(ATT)]
key. The “ATT” icon will appear on the display. You should also hear a decrease in
the incoming signal strength (and background noise) with the Attenuator.
2.
To switch the Attenuator off, press the [F] key momentarily, then press the [1(ATT)]
key; the “ATT” icon will disappear from the display.
NB (Noise Blanker)
For reduction of impulse noise, such as that produced by automotive ignition systems,
the noise blanker feature may prove helpful.
1.
To activate the Noise Blanker, press the [F] key momentarily, then press the [0(NB)]
key. The “NB” icon will appear on the display. You should observe a reduction in the
ignition noise
2.
To switch the Noise Blanker off, press the [F] key momentarily, then press the
[0(NB)] key; the “NB” icon will disappear from the display.
RF TUNE
This feature allows you to shift the RF passband to reduce the interference.
1.
Press the [F] key momentarily, then press the [8(RF TUNE)] key to activate the RF
TUNE feature.
2.
Rotate the DIAL knob to the position where the interference is eliminated, the press
the [ENT(SET)] key
24
VR-5000
Operating Manual
3.
To disable the RF TUNE feature,
Display Dimmer
The LCD’s illumination level may be adjusted by the front panel keys.
1.
To adjust the LCD illumination level, press the [V(DIM)] key momentarily to enable
the LCD illumination level.
2.
Rotate the DIAL knob to adjust the illumination level “0 (dim) ~ 7 (bright).” As you
make the adjustment, you will be able to see the effects of your changes.
3.
When you have completed the adjustment, press the [ENT(SET)] key to save the
new setting and exit to normal operation.
Display Contrast
The display contrast may be adjustable, as well.
1.
Press the [F] key momentarily, then press the [ENT(SET)] key.
2.
Rotate the DIAL knob to select the cursor to the “MISC” menu, then press the
[ENT(SET)] key.
3.
Rotate the DIAL knob to select the cursor to the “LCD CONT” menu, then press the
[ENT(SET)] key.
4.
Rotate the DIAL knob to adjust the comfortable contrast level “0 (weak) ~ 15
(thick).”
5.
Rotate the DIAL knob to select the cursor to the “END” menu, then press the
[ENT(SET)] key.
6.
Confirm that the cursor is on the “WRITE” menu, press the [ENT] key to save the
new setting and exit to normal operation.
Keypad Locking
In order to prevent accidental frequency change, the VR-5000’s keys and switches may
be locked out.
1.
To lock out the keys and switches, press the [F] key momentarily, then press the
[2(LOCK)] key. The “KEY” icon will appear on the display.
2.
To cancel locking, press the [F] key momentarily, then press the [2(LOCK)] key; the
“KEY” icon will disappear from the display.
Keypad Beeper
If the keypad’s beeper creates an inconvenience (particularly when operating at the
midnight, it may easily be disable.
25
VR-5000
Operating Manual
1.
To disable the keypad beeper, press the [F] key momentarily, then press the
[•(BEEP)] key.
2.
If you wish to re-enable the keypad beeper, press the [F] key momentarily, then
press the [•(BEEP)] key.
26

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 26
Creator                         : .橡.Microsoft Word
Create Date                     : 2000:06:01 17:50:12
Title                           : .橡.VR-5000_OperatingManual.PDF
Author                          : .橡.USER090
Producer                        : Acrobat PDFWriter 4.0 Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K66VR-5000

Navigation menu