8800 Series Electrified Mortise Solenoid Locks Installation Instructions Instructions for Wiring 8800 Series Electrified Mortise Solenoid Locks, 8800 Series Monitoring Suffixes REX, LBM & DBM & Combined Solenoid & Monitoring Suffixes with Pluggable "ElectroLynx Connector System" NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE LOCK AND VOID THE FACTORY WARRANTY. For Technical Assistance call Yale® at 1-800-810-WIRE (9473) Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Yale Locks & Hardware makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. 80-8800-0005-000 (07-14) An ASSA ABLOY Group brand Introduction This instruction manual includes wiring instructions for all electrical types of 8800 series electric mortise locks to ElectroLynx Hinge Connector System. The correct wiring configuration must be selected depending on type and function of the mortise lock being installed. Multiple functions can be combined (ex: 8890FL REX-LBM). Refer to table on page 4 to select appropriate wiring instruction for mortise product being installed. Important Disconnect all input power before beginning installation to prevent electrical shock and equipment damage. Installer must be a trained, experienced service person. All wiring must comply with applicable local electrical codes, ordinances and regulations. CAUTION: The DC voltage applied to the lock solenoid must not exceed 12 / 24 VDC +/- 10% If the voltage exceeds these values the solenoid may be damaged or not function. Specifications / Functions Solenoid Type: 12 or 24VDC, Intermittent or Continuous Duty 612mA Peak @12VDC 500mA Steadystate @12VDC 330mA Peak @24VDC 612mA Steadystate @24VDC Fail Safe: Models 8880, 8884, 8886, 8888, 8890, 8894-2, 8896 and 8898 Fail Secure: Models 8881, 8885, 8887, 8889, 8891,8895-2, 8897 and 8899 REX-, LBM-, and DBM- Lock Switches: contact rating for all switches: 2 Amp max @ 30VDC REX (Request to Exit). Lever Monitor Switches. The 8800 REX series mortise lock is designed to allow monitoring of inside and outside lever rotation. The lock uses two switches to monitor the inside and outside lever hubs. LBM (latchbolt monitor switch). The 8800 LBM series mortise lock provides positive indication of latchbolt extension or retraction when the lever is rotated retracting the latchbolt, latchbolt being retracted by key, or if the latchbolt itself is depressed. DBM (deadbolt monitor switch). The 8800 DBM series is designed to monitor the position of the dead bolt. LPM (Lock Performance Monitor). The 8800 LPM series provides a status check on the lock’s main components. ® Case Molex Connectors: 8-Pin: Lock Options 4-Pin: REX Cover 2 80-8800-0005-000 (07-14) An ASSA ABLOY Group brand Installation Notes 1. With new applications a raceway harness with 8 and 4 pin connectors will be pre-installed inside door by ASSA ABLOY door manufacturer when specified during ordering process. Raceway harness kits are available for retrofit applications and for doors manufactured by non-ASSA ABLOY manufacturers. 2. Wiring to pigtail harness is per facility wiring requirement. Follow individual instructions below. 3. If door raceway connectors are not present, remove lock connector and follow wiring in Option A . Option A Sample wiring 8880 Thru 8899 series solenoid locks with a 12 or 24VDC Regulated and Filtered Power Supply (Wiring shows power on and lock in secure state) 12 or 24VDC Regulated and Filtered Power Supply (Recommended Securitron BPS series) Normally Closed Fire Alarm Contact (If Required) Pigtail harness (Supplied with McKinney Hinge) (2 wires with 8-pin connector) NO Red (+), 2 C NC *Switch or relay contacts Input +- L N 120VAC 60HZ 12 or 24VDC Black (-), 1 8 7 6 4 5 3 2 1 Plug into 8-pin hinge connector at door GND 120VAC L/N/G * NOTE: Wire 8880, 84, 86, 88, 90, 94-2, 96 & 98 (Fail Safe) Locks to switch as shown. For 8881, 85, 87, 89, 91, 95-2, 97& 99 (Fail Secure) Locks wire NO (Normally Open) contact to red wire of pigtail harness. Options (8 wires) Red (+), 2 8 7 Black (-), 1 6 4 5 3 2 1 REX (4 wires) Plug in here Installation and wiring instructions Lock, raceway, electric hinge and pigtail 8-pin terminations colors all match 1. Install door. Plug electric hinge and lock connectors into raceway connectors. 2. Wire option A to pigtail harness. 3. Ensure proper supply voltage is being applied at pigtail harness. CAUTION: The DC voltage must not vary beyond 12V+/- 10% or 24V+/- 10%depending on lock solenoid installed. If voltage exceeds these values, the lock solenoid may be damaged or not function. Pigtail harness (2 wires with 8-pin connector) 8 7 6 4 5 3 2 1 Black (-) Red (+) White Green Orange Blue 8-wire Brown Electric Hinge Yellow with 8-pin connectors Raceway harness with 8 & 4 pin connectors Note: Typical raceway location is shown. Other locations may exist depending on door type. 4. Plug pigtail harness 8-pin connector into electric hinge 8-pin connector. 5. Test lock - Applying 12 or 24VDC unlocks fail secure applications and locks fail safe applications. 3 80-8800-0005-000 (07-14) An ASSA ABLOY Group brand ELECTRIFIED OPTIONS Molex ® 8890 Options 8891-ITS 8-Pin Function Color Function Color 1,2 Power Black/Red Power Black/Red 3,4 LPM Green/Gray -------------OR------------LBM Green/Green LPM Green/Gray 5,6 DB-In Yellow/Yellow CX Brown/Brown Blue/Blue DPS* Blue/Blue DPS* 7,8 (Less DB) 4-Pin Function Color Function Color 1,2 Open Loop REX White/White Open Loop REX White/White 3,4 Closed Loop REX Gray/Gray Closed Loop REX Gray/Gray REFERENCES REX Request to Exit LBM Latch Bolt Monitor LPM Latch Performance Monitor DBM Deadbolt Motintor DB Deadbolt DB-In Deadbolt Retracted DB-Out Deadbolt Extended DPS Door Position Sensor CX Cylinder Monitor * Deadbolt not available with DPS function. Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication. Yale Security Inc. reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials. Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-8800-0005-000 (07-14) An ASSA ABLOY Group brand
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 4 Create Date : 2014:07:23 12:20:26-04:00 Modify Date : 2014:07:23 12:20:26-04:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : Owner Creator : CorelDRAW X6 Title : Untitled-1EXIF Metadata provided by EXIF.tools