7110(F), 7170(F)(LBR)
Surface Vertical Rod Exit Device Series
Installation Instructions
All dimensions are in inches (mm) unless otherwise noted.
Dogging
Feature to hold bolts retracted and
touchpad depressed, for push-pull door
operation.
To Dog Device
1. Insert dogging key.
2. Hold touchbar depressed.
3. Turn key 1/4 turn clockwise.
(Not a feature of fire labeled devices.)
PPHMS PHILLIPS PAN HEAD MACHINE SCREW
PPH”AB”SMS
PFHUMS
PFHMS
PRH”AB”SMS
PFH”AB”SMS
PHILLIPS PAN HEAD TYPE “AB” SHEET METAL SCREW
PHILLIPS FLAT HEAD MACHINE SCREW
PHILLIPS FLAT HEAD TYPE “AB” SHEET METAL SCREW
PHILLIPS ROUND HEAD TYPE “AB” SHEET METAL SCREW
PHILLIPS FLAT HEAD UNDER CUT MACHINE SCREW
FASTENER DESCRIPTION
ABBREVIATION
PTH”AB”SMS PHILLIPS TRUSS HEAD TYPE “AB” SHEET METAL SCREW
(2) 1/4-20 X 1" PPHMS
(Metal Door)
or
(2) #14 x 1-1/2" PPH”AB”SMS
(Wood Door)
Cover
(3) 10-24 x 1/4" (6mm) PPHMS
Top Latch
(Panic & Fire Label)
Bottom Bolt Case
Panic & Fire Label
Top Rod
(2) 1/4-20 X 3/4" PFHMS
(Metal Door)
or
(2) #14 x 1-1/2" PFH”AB”SMS
(Wood Door)
Bottom Rod Assembly
Deadbolt
790 Strike Bolt Case Cover
(2) 8-32 x 1/4" (6mm) PFHMS
Bottom Mounting Plate
(2) #8 x 1/2" (13mm) PRH”AB”SMS
Guide Cover
(2) #6 x 3/8" (10mm) PTH”AB”SMS
Rod Guide
Roll Pin
Latch Cover
791 Strike
Strike Plate
Shim (2) Supplied
(3) 10-24 x 3/4" (19mm) PFHMS
Top Mounting Plate
Hole Plug
(Fire Label Devices)
(2) 8-32 x 5/16" (8mm) PFHUMS
Rod Guide
Guide Cover
(3) 10-24 x 1/4" (6mm)
PPHMS
(2) 8-32 x 1/4" (6mm) PFHMS
(2) #6 x 3/8" (10mm)
PTH”AB”SMS
Top Rod Connector
(2) #8 x 1/2" (13mm) PRH”AB”SMS
(2) 1/4-20 X 3/4" PFHMS
(Metal Door)
or
(2) #14 x 1-1/2" PFH”AB”SMS
(Wood Door)
‘
Dogging Key
(3) 8-32 x 5/16"
PFHUMS
(2) 1/4-20 X 1" PPHMS
(Metal Door)
or
(2) #14 x 1-1/2" PPH”AB”SMS
(Wood Door)
End Clamp
End Cap
Top bracket and 726 strike
required for 7170(F)(LBR).
Strike Angle Must
Engage Strike 726
Top Strike
12-24
PRHMS
PRHMS PHILLIPS ROUND HEAD METAL SCREW
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
T
op Latch & 791or 726
Strike T
emplate
Device Template
Floor Strike Template
FINISHED FLOOR or THRESHOLD
Bottom Case
Template
To Change Hands
Check Before Starting
Unreinforced Doors or Frames
Doors and Frames with walls having a structural
thickness (metal skin plus reinforcement or solid
hardwood) to engage less than (3) full screw threads
are considered unreinforced.
Unreinforced Doors: Use SNB (sex nuts and bolts).
Unreinforced Frames: Use Blind Rivet Nuts.
Recommended fasteners for unreinforced openings
are not necessarily supplied by Yale Locks and
Hardware.
Reinforcement
Door Skin Blind Rivet Nut
Door Must Swing Freely
Min. Door Stile
4-1/2" (114mm)
Maintenance
1. Periodically remove covers and coat mechanisms with a
silicone base lubricant. This is particularly required in corrosive
environments for proper product function.
2. Check mounting fasteners periodically. Retighten if found
loose. Apply screw locking compound (available at automotive
part stores) or change part fasteners if screws continue to back
out.
3. Periodic checks (and adjustments) of strikes are required to
compensate for changes in the opening (e.g. door sagging).
1. Mark Door
Door and frame must
meet structural and
dimensional specifications
on exit device template(s)
for door and frame
preparation.
2. Prepare Door, Frame, & Sill
(4) 8-32 x 3/16" PPHMS
Vertical Lifter Assembly
Remove (4) Screws and
Vertical Lifter Assembly.
Rotate device to opposite
hand (180 degrees). Insert
Lifter Assembly under Lift
Block and re-install screws.
Lift Block
Single Door or Pair without Mullion
Locate and Mark Horizontal and Vertical Reference Centerlines as shown.
LHR door shown, preparation is typical for both door hands.
Note: Door should be in the closed position while marking horizontal and
vertical reference lines. Paper or the Plastic Template may be used in this step.
FINISHED
FLOOR
or THRESHOLD
A. Locate “Device Template” aligning VERTICAL REFERENCE and HORIZONTAL
REFERENCE lines. Tape template to door face.
B. Extend centerline of Rod and Strikes from “Device Template” to door top and
bottom, on door face.
C. Locate Top Latch/Strike and Bottom Bolt Case templates in place over centerline
of Rods and Strikes on door. Tape templates in place and mark holes.
Note that the centerline of the rods and strikes used to install top and bottom bolts
is not the Vertical Reference centerline.
D. Locate and tape Trim Template to door when required (See instructions packed with Trim).
E. Mark and prepare holes per installation template (exclude 791 or 726 strike, holes
prepared in Step 7).
F. Locate 790 Bottom Strike Template. Tape in place over Rods and Strikes centerline
on door. Tape template in place and mark hole locations. Holes to be prepared in Step 7.
G. Remove templates from door.
LHR Device
LHR DoorRHR Door
Vertical Lifter Assembly
(4) 8-32 x 3/16" PPHMS
RHR Device
LHR DOOR
INSIDE FACE
VERTICAL
REFERENCE
HORIZONTAL
REFERENCE
39-15/16
(1014)
LHR DOOR
INSIDE FACE
VERTICAL
REFERENCE
HORIZONTAL
REFERENCE
Rods & Strikes
2
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
3
4. Mount Device & Components
3. Size Device
Device must be field cut to size, as required
HINGE SIDE OF DOOR
C
L
STILE
* LHR Door (Door Open)
inside face
STOP
SURFACE
CUT
LINE
2-1/4
(57)
1-3/8
(35)
Min.
Horizontal line
Dogging
Hole
3/8
(10)
Min.
Determine device length
1. Close door. Measure 2-1/4" (57mm)
from the Stop Surface on the hinge side of
the door, mark Horizontal Reference at
this point.
Note: This dimension must be 3/8"
(10mm) minimum from edge of the stile
on the door.
2. Open door. Align mounting holes in
device with Mounting Holes in the door.
Mark device where it crosses the mark
from Step 1. If mark is less than 1-3/8"
(35mm) min. from Dogging Hole, a shorter
device is required.
3. Before cutting, make sure the End
Cover is in place and there is no gap
between it and the Pushpad. Cut device
on mark from Step 2.
D
End
Clamp
Rod Guide
Top
Mounting
Plate
790 Strike
Top
Latch
C
LDevice Mounting Holes,
Rods, & Strikes
Rod Guide
(2) 1/4-20 x 3/4" (19mm)
PFHMS
(3) 10-24 x 1/4" (6mm)
PPHMS
791 Strike
Bottom
Mounting
Plate
Bottom Bolt
Case
(2) 1/4-20 x 3/4" (19mm)
PFHMS
(3) 10-24 x 1-1/4" (32mm)
PPHMS
Bottom Bolt
Case
F
Device
C
L
C
B
D
F
16-3/8
(416)
15
(381)
1/2
(13)
Figure 3.
Note: 726 Strike and top
bracket not shown.
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
4
7. Complete Installation
5. Rod Preparation & Assembly
A. Top Rod Sizing
1. For openings under 7' (2134mm), subtract the actual
opening height from 7' (2134mm).
Example: 6'8" (2032mm) opening
7'0" (2134mm) - 6'8" (2032mm)
= 4" (102mm)
Top Rod must have 4" (102mm) cut from end with
1/8” (3mm) thru hole. Use attached drill fixture to
locate and re-drill 1/8" (3mm) dia. hole thru the
top rod. Make sure rod bottoms out inside drill fixture
prior to drilling. (See Figure 5A).
2. For opening over 7' (2134mm), subtract 7' (2134mm)
from the actual opening height.
Example: 7'6" (2286mm) - 7'0" (2134mm)
= 6" (152mm).
Top Rod must have a 6" (152mm) extension added
to length (See below for available rod lengths).
B. Assemble Top Rod
Insert Top Rod Connector into sized Top Rod and Install
1/8" (3mm) x 1/2" (13mm) Roll Pin thru both pieces until
flush on both sides. (See Figure 5B).
Top Rod
Flat Face
(2 Sides)
Top Rod
Connector
Flush
1/8" (3mm)
x 1/2" (13mm)
36-1/8
(918)
1/8
(3)
Drill Fixture
3/8
(10)
Figure 5B: Top Rod Assembly
Figure 5A: Drill Pin Hole
Note: Below listed instructions are based on a device
mounted 39-15/16" (1014mm) from finished floor
or threshold. Any deviation on device mounting
height must be accommodated to insure proper
device function.
6. Bottom Bolt Assembly
A. Thread Bottom Bolt into Bottom
Rod Assembly.
B. Leave 1/2" (13mm)
for adjustment. Bottom Rod
Assembly
Bolt
1/2
(13)
3-7/8
(98)
32-1/4
(812)
Adjustable
(Ref.)
Bolt
Engagement
Frame
Stop
Rod Guide
A2
A
3/8"
(10)
Cover
Screw
Hole
Cover
Screw
Hole
Cover
Screw
Hole
Cover
Screw
Hole
Note: Bottom Bolt will retract to
1/8" (3mm) above Floor Strike.
Floor covering in the door path
must be laid out accordingly.
Top Strike Detail
Shim
(2) Supplied (Start With One)
Strike Plate
(Ridges Face Down)
791 Strike
(3) 10-24 x 3/4" (19mm) PFHMS
B2
790 STRIKE
(Press in place)
A. Install Top Rod and 791 Strike
1. Thread Top Rod Assembly onto Top Latch.
Lift rod to fully retract Top Latchbolt.
Depress Pushpad and hold depressed.
Adjust top rod length until Rod Connector
seats into the Slide Assembly in latch case.
Note: For 7170 devices, skip section (2a)
and 2(b). See the installation instructions
for the 726 strike on page 9.
2a. Position the Top Strike Roller between
the Tripping Lever and the Bolt on the
Top Latch. Verify hole positions and
prepare holes per Installation Instruction
Template.
b. Install Top Strike and Strike Plate using
(2) #10-24 x 3/4" (19mm) PFHMS thru
outer slots. Adjust and shim strike as
needed for zero door rattle. Add third
screw (#10-24 x 3/4" (19mm) PFHMS)
after final adjustments.
3. If Top Bolt does not remain retracted when
door is opened, Top Rod is too short. Pull
rod out of the guide and the slide then
rotate rod to increase length. Upper Bolt
should retract flat.
4. If upper latch will not deadlock, Top rod
is too long. Pull rod out of the guide and
the slide and rotate to decrease length.
* If 7170 LBR, skip section B.
B. Install Lower Rod and 790 Strike
1. With door open, actuate Pushpad to
retract upper latch. Hang Lower rod
from bottom of Slide and adjust bolt so
that it clears the finished floor by 1/4".
2. Verify location of pipe strike template.
Prepare the strike hole and install the
pipe strike. Set in place with appropriate
bonding material.
3. With the door open, actuate pushpad
to retract upper latch. Adjust bolt
height by pulling the rod out of the
guide and slide and rotating until the
bolt clears the pipe strike by 1/8".
C. Test device action by Touchbar,
by Trim, by Dogging
D. Install covers
A1
B
Rod Guide
Slide
Roller
Bolt
Tripping
Lever
60-1510-0280: 2" (51mm)
60-1510-0277: 6" (152mm)
60-1510-0278: 12" (305mm)
(Specify Device Finish)
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
Thru Bolt
(Metal or Wood)
Wood Door
HOLE “A”
PREPARATION
#14 x 1-1/2"
PPH”AB”SMS Drill: #9 (.196" dia.)
DOOR/FRAME FASTENER
1/4-20 SNB
1/4-20 PPHMSMetal Reinforced Drill: #7 (.201 dia.)
Tap: 1/4-20
3/8" (9.5mm) dia.
Thru door
5
CUTLINE
14
16 "
9
14
"
16
9
22
"
8
7
4"
57
1
2
33
15
16 "
FRAME STOP
TAPE TO
C
L RODS
(SEE TABLE
FOR SIZES)
HOLE 'A'
TAPE TO
DOOR STOP
ALIGN WITH
TOP LATCH &
791 STRIKE
(7110 only)
FOLD LINE
(STOP LINE)
#26 (.147" DIA) DRILL
10-24 TAP
(2 HOLES)
A
A
C
13
8"
35
15
16 "
33
C
L
BOTTOM
TAPE THIS TAB TO
ALIGN WITH
BOLT CASE
TAPE TO
BOTTOM DOOR EDGE
DOOR STOP
RODS
BOTTOM DOOR EDGE
HOLE 'A'
FOR SIZES)
(SEE TABLE
FOLD ON LINE &
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
6
This page left blank intentionally.
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
7
C
5
8" (16) DIA. X
3/4 (19) DEEP
LHR DOOR
FOLD LINE
790 STRIKE
DEVICE TEMPLATE
CUTLINE
DEVICE TEMPLATE
RHR DOOR
11
16 "
17
11
16 "
17
35
8"
92
"
92
5
38
L
RODS
C
L
C
L
VERTICAL REFERENCE
C
L
C
HORIZONTAL REFERENCE
CUTLINE
16
17
"
11
C
L
ALIGN WITH OF RODS
TAPE TO
DOOR FACE
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
8
This page left blank intentionally.
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
9
726
Top Strike
12-24
PRHMS
Top Latch Case
Strike Angle Must
Engage Strike
Strike Angle and Top
Latch Mounting Plate
(2) Mounting Screws 1/4-20 x 3/4 PFHMS
726 STRIKE
TAPE THIS TAB TO FRAME STOP
TOP LATCH
& STRIKE
FOLD
(STOP LINE)
ALIGN WITH OF RODS
C
L
TAPE TO DOOR
DOOR FASTNER HOLE 'A'
METAL
REINFORCED SCREW 1/4-20 TAP
HOLLOW
METAL &
ALUMINUM
OPTIONAL
SNB
5/16 (8) DIA
INSIDE DOOR
FACE
3/8 (10) DIA
OUTSIDE
DOOR FACE
ALUMINUM SNB THRU DOOR
CUTLINE
1-5/16"
(33)
2-1/4"
(57)
3/4"
(19)
1/4"
(6)
1/8"
(3)
1/4"
(6)
3/4"
(19)
1/8"
(3)
3/4"
(19)
3/4"
(19)
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)
10
Product Support Tel 800.438.1951 • www.yalelocks.com
Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their respective
owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication.
Yale Security Inc. reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials.
Copyright © 2002, 2013, Yale Security Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
For use in conjunction with instruction sheets packed with exit device.
Holes and slots are identified below by exit device series and trim. Prep door and frame for only those
features required for the exit device being installed.
Frame
Door Stop
Door
Template
All 7000 Exit Devices
All 7000 Exit Devices
7120(F), 7160(F)
& 7220M(F) CVR
757F
Strike
Location
Mortise
7130(F)
7150(F)(WS), 7170(F)(WS)
Against Door Stop
or Mullion
(when applicable)
Vertical Reference
Wide Stile
Trim Only
Against Door Surface
Wide Stile
Trim Only
Horizontal
Reference
Wide Stile
Trim Only
Vertical Reference
Narrow Stile
Trim Only
7120(F), 7160(F)
& 7220M(F) CVR
Plastic Installation Template
7000 Exit Devices
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
An ASSA ABLOY Group brand
80-9470-0010-000 (03-13)