Yale 2 7130(F) Series Mortise Exit Devices Installation Instructions 80 9470 0030 00003 137130Mortise
User Manual: Yale 7130(F) Series Mortise Exit Devices Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
7130(F) Series Mortise Exit Devices Installation Instructions Outside Trim Device is packed ready for any Yale 650F or 660F Series Trim. (3) 8-32 x 5/16" PUFHMS End Clamp End Cap (2) 1/4-20 x 1" PPHMS Mortise Lock (See Mortise Lock Chart) Hole Plug (Fire Devices) (2) 12-12-24 FHPWMS 798 Universal Strike Dogging Key Device Assembly (2) 1/4-20 x 3/4" PRHMS (Special Head) Armor Front Cover Armor Front Screw (2) 12-12-24 FHPWMS (2) 8-32 x 5/16" PUFHMS ABBREVIATION FASTENER DESCRIPTION PPHMS PHILLIPS PAN HEAD MACHINE SCREW PRHMS PHILLIPS ROUND HEAD MACHINE SCREW FHPWMS FLAT HEAD PHILLIPS WOOD/MACHINE SCREW PUFHMS PHILLIPS UNDER CUT FLAT HEAD MACHINE SCREW Mortise Lock Chart Function Exit Only F02 F03 (Knob) F03 (Lever) F05 F06 (Knob) F08 (Lever) Lock Number Panic Label Fire Label 35K 35KF 35L 38T 38K 38L 35LF 38TF 38KF 38LF Attention Installer Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Yale Locks & Hardware makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. All dimensions are in inches (mm) unless otherwise noted. 80-9470-0030-000 (03-13) An ASSA ABLOY Group brand To Change Hand Maintenance For Metal, Composite and Wood Doors Handed Mortise Lock 1. Periodically remove covers and coat mechanisms with a silicone base lubricant. This is particularly required in corrosive environments for proper product function. (See "To Change Mortise Lock Hand", below) 2. Check mounting fasteners periodically. Retighten if found loose. Apply screw locking compound (available at automotive part stores) or change part fasteners if screws continue to back up. Device is non handed Shim Kit Option List Number: 723W Black Finish Kit consists of Latch Head Shim (Device Cover seats on shim) and End Clamp Shim (End Cap seats on shim). RHR Door Each shim is 1/8 (3.2) thick. More than two Shim Kits require longer device mounting screws (not included). LHR Door To Change Mortise Lock Hand Typical Lock Body with Cover removed and showing only components relevant to lock handing. Other components vary according to function. Guardbolt Plate Assembly (Hold in place while removing guardbolt) Spring (Note position before removing guardbolt) Remove latchbolt assembly in this direction. Guardbolt Push In Note position of Guard Lever Latchbolt Guard Lever To change lock hand remove, flip latchbolt and guardbolt and reinstall. Nylon Washer (must be between spring and bracket in case) Check Before Starting Unreinforced Doors or Frames Min. Door Stile 4-1/2" (114mm) Door and frame must meet structural and dimensional specifications on exit device template(s) for door and frame preparation. Doors and Frames with walls having a structural thickness (metal skin plus reinforcement or solid hardwood) to engage less than (3) full screw threads are considered unreinforced. Unreinforced Doors: Use SNB (sex nuts and bolts). Unreinforced Frames: Use Blind Rivet Nuts. Recommended fasteners for unreinforced openings are not necessarily supplied by Yale Security, Inc. Door Must Swing Freely Reinforcement Door Skin Blind Rivet Nut 2 80-9470-0030-000 (03-13) An ASSA ABLOY Group brand 1. Mark Door Locate and Mark Horizontal and Vertical Reference Centerlines as shown. LHR door shown preparation is typical for both door hands. DOOR, LOCK AND STRIKE (ANSI A115.1 BACKSET) Note: Centerline of Lock (cutout) must match Horizontal Reference centerline. Finished Floor 2. Prepare Door & Frame Factory prepared cutouts with field drilled mounting holes are recommended. If door (lock) and frame (strike) have to be mortised in the field, do it before continuing (follow instructions on Installation Template). Spot and Prepare Mounting Holes As Follows: A. Locate and tape Trim Template to door. (See instructions packed with Trim.) B. Locate “Device Template” aligning VERTICAL REFERENCE and HORIZONTAL REFERENCE lines on door and template. Tape template to door face. (1) slot 1/2" (12.7) Dia. x 1" (25.4) on centers thru inside door face and (2) Device holes for 1/4-20 Machine Screws*, or for 3/8" (9.5) Dia. Sex nuts and Bolts. (*) Metal reinforced doors only. Device Template C. Insert lock into mortise, adjust front for door edge (beveled or flat)*. (2) Lock holes for 12-24 Machine Screws or for #12 Wood Screws. (*) NOTE: Lock base front has to be field tightened in place, (two screws, each on lock case top and bottom). D. Seat strike in frame cutout. (2) Strike holes for 12-24 Machine Screws, or for #12 Wood Screws. 3 80-9470-0030-000 (03-13) An ASSA ABLOY Group brand 3. Size Device 4. Clear Raised Door Molding Device must seat flush on door surface, or on shims that keep it parallel to door face. One Shim Kit #723W required for each 1/8" (3mm) of device lift needed. Two Shim Kits Maximum for standard device in 1-3/4" (44) door. For thicker doors, consult the factory. One Shim Kit #723W per 1/8" (3mm) of raised molding. 4 80-9470-0030-000 (03-13) An ASSA ABLOY Group brand 5. Install Components A. Install Lock Lock in hand, depress guardbolt. Check that latchbolt is deadlocked. Check that latchbolt lever (and cylinder lever, hubs, and thumbpiece lever, if relevant) operate the lock freely. Insert Lock Body into door cavity. Fasten to door edge (2 FHPWMS) Note: Make sure that door reinforcing clips or doorwalls support lock immovable (restricting rocking motion). B. Install Armor Front Fit over bolts and fasten to lock base front (2 PUFHMS). Check that bolts retract and extend freely. C. Install Strike Seat in place (lip bend away from opening). Fasten to frame (2 FHPWMS). D. Install Trim Follow instructions packed with trim. E. Install Device Seat Bar in place (Device finger must engage latchbolt lever, thru slot in lock case/cover, as shown in Detail 1). Fasten Device Head (2 PRHMS or SNB). Set Bar level. Locate End Clamp holes. Prepare end Clamp mounting holes. Fasten End Clamp in place. (2 #1/4-20 PRHMS or 3/8" (9.5) dia SNB) F. Check Operation 1. Depress touchbar (bolt must retract). Release touchbar (bolt must extend). 2. Actuate trim (bolt must retract). Release trim actuator (bolt must extend). 3. (NOT FOR FIRE DEVICES). Depress touchbar, turn dogging key clockwise (bar must remain depressed, bolt must remain retracted). Turn dogging key counterclockwise (bar and bolt must return to extended position). 4. Close door. Latchbolt should fully engage into strike cavity, guardbolt should retract over strike ramp. Door should not rattle. NOTE: When resulting operation if faulty, check first for visible binding or interference. If there is no apparent reason for the fault, remove item from the door and recheck its operation before assuming that it is defective. DETAIL 1 G. Tighten all mounting screws. 5 80-9470-0030-000 (03-13) An ASSA ABLOY Group brand 6. Install Head Cover and End Cap Use (2) 8-32 PUFHMS for Head Cover Use (3) 8-32 PUFHMS for End Cap Product Support Tel 800.438.1951 • www.yalelocks.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication. Yale Security Inc. reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials. Copyright © 1996, 2013, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited. 6 80-9470-0030-000 (03-13) An ASSA ABLOY Group brand
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Owner Create Date : 2013:03:06 22:44:14-05:00 Modify Date : 2013:03:07 08:50:43-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Owner Title : Untitled-2 Creator Tool : CorelDRAW X6 Metadata Date : 2013:03:07 08:50:43-05:00 Producer : Corel PDF Engine Version 16.1.0.843 Document ID : uuid:5d31c8d2-9b4f-4666-b207-c24712e4618c Instance ID : uuid:7f62c18d-5878-4505-8ac3-a67b254886af Page Count : 6 Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract)EXIF Metadata provided by EXIF.tools