Yale 1900 Series Door Closer Look Viewer Manual For Print
User Manual: Yale 1900 Series Door Closer Catalog
Open the PDF directly: View PDF .
Page Count: 24
Download | |
Open PDF In Browser | View PDF |
1900 Series Traditional Door Control An ASSA ABLOY Group brand 1900 series door closer the engineer's choice The Yale® 1900 Series Traditional Surface Closer offers conventional closer styling in combination with contemporary closer control and the installation convenience of a one-size closer shell. Only two spring sizes are required to provide control for the complete range of door sizes. The 1900 Series Door Closers are designed for traditional and period decor while at the same time meeting the strict requirements of engineers worldwide. The Yale® 1900 Series Traditional Closers are available for standard arm, parallel arm or corner bracket installation. Rigid heavy-duty arms are available for Parallel Rigid and UNI Stop™ Parallel arm installations. Each type of installation is available with non-hold open or hold open arms. A variety of accessories is available to meet most installation requirements. contents Introduction . . . . . . . . . . . . . . . . . . . 2 Overview . . . . . . . . . . . . . . . . . . . . . . 3 Features . . . . . . . . . . . . . . . . . . . . . . . 4 Applications . . . . . . . . . . . . . . . . . . 5-6 Technical Details . . . . . . . . . . . . . 7-10 Accessories . . . . . . . . . . . . . . . . 11-16 Parts List . . . . . . . . . . . . . . . . . . 17-21 How To Order . . . . . . . . . . . . . . . . . 22 finishes Product will be painted with a combination of waterborne acrylic and polyester powder coat. Closers will withstand 100 hours of salt spray. (The ANSI requirement is 25 hours.) Sprayed Finishes Description Specify Designation (ANSI/BHMA) Complements the following finishes Old Designation Aluminum 689 625, 628, 629, 630, 651, 652 Statuary Bronze 690 613, 640, 695 STAT Dull Bronze 691 612, 637, 639 BL Black 693 315 315 Medium Amber 694 312 312 Gold 696 605, 606, 632, 633 GB Prime Coat* 600 — SB SRI *600 is a special rust-inhibiting prime coat. Closers can be ordered prime coat only (specify closer x 600). An additional charge applies if finish coat is required over prime coat (ex: 1902/4 x 600 x 690). 2 Page Revised Electronically 2/14 1900 series door closer overview Size Designation Spring Power Adjustment 2/4 = Sizes 2 thru 4 5/6 = 5 & 6 Aluminum Alloy Shell Regulating Valve Regulating Valve compliance standards All 1900 Series closers comply with ANSI/BHMA A156.4 Grade 3 Specifications. All Yale® series 1900 closers with non-hold open arms are listed by Underwriters Laboratories for labeled fire doors. This includes compliance to UL10C and for 3-hour assemblies. The product is manufactured in an ISO 9001 facility. specifications Closer for interior (and) exterior doors shall be rack-and-pinion type enclosed in a cast aluminum alloy shell. Closer spring shall be clock-type coil spring and shall be adjustable through a range of closing power. Closer fluid shall maintain lubricity and contain anti-oxidation agents. Closer shall be equipped with a single hex-key operated regulating valve for control of both closing and latch speeds. Closer shall have adjustable backcheck. Closer shall be Yale® 1900 Series Traditional Surface Closer or equivalent. 3 1900 series door closer features One-Size Aluminum Housing Closer is housed in special aluminum alloy shell selected for its ability to provide optimum performance. One body size provides simplified templating and installation. Adjustable Spring Power Clock-type coil spring allows incremental adjustment of closer power to meet individual installation needs. Permits a fine adjustment of the closer to the environment. Rack and Pinion Design Provides a smooth constant control of the door through its full opening and closing cycle. Adjustable Closing Speed/Latch Speed A dual-purpose regulating valve, hex-key operated, permits independent adjustment of both sweep and latch speed. Adjustable Backcheck Cushioning An independent regulating valve, hexkey-operated, provides an adjustable hydraulic cushion to the door opening speed toward the end of the opening cycle. This feature is standard with all but delayed action closers. Backcheck is not available with delayed action closers. Non-Hold Open Arms Standard closer will be supplied with a non-hold open arm. This arm is nonhanded. Adjustable Power Standard Installation Jamb Bracket Provides a ±7-1/2% power adjustment by relocation of the forearm pin in the jamb bracket. Supplied standard with all standard installation and corner bracket installation non-hold open closers. Hold Open Arms Closer arm has adjustable hold open feature (90° to 180°). This arm is nonhanded for regular arm application only. It is handed for all friction hold open parallel arm installations. Field Reversible Closer spring can be reversed to accommodate the hand of the door. It is recommended that wherever possible the closer be ordered handed. Parallel hold open arms and delayed action closers are not reversible. Adjustable Delayed Action Closing Closer’s initial closing speed at the beginning of the closing cycle (from full open down to approximately 70°) is adjustable, allowing slow-moving traffic to pass through the opening before the closer begins its normal closing speed. For regular arm non-hold open closers only. Delayed action closers are not available with backcheck cushioning. Delayed action closers are handed. optional features Adjustable Delayed Action Closing* (Supplied in lieu of backcheck feature) An optional hydraulic feature that adds a third speed range to the closing cycle. This feature becomes effective when the door is opened and released at any point beyond 70°. The amount of time delay depends upon the combination of the angle of door release and valve adjustment. The valve can be adjusted with a 1/8" (3mm) hex key from no delay time up to maximum delay times of: Door Opened and Released at Approximate Time of Delay Cycle 180° 4-5 minutes 120° 2-3 minutes 90° 25-30 seconds *Note: Regular arm (NHO units only) are handed - not reversible 4 Suggested Applications Delayed action closing allows slowmoving traffic to clear the opening before the door closer’s normal closing cycle begins. This feature can be helpful in health care facilities such as hospitals and nursing homes. It provides sufficient time for persons on crutches or in wheelchairs to pass through a door without concern of it closing. At the same time, it can accommodate the facility's staff with movement of food service carts, beds, and other wheeled traffic. Use of delayed action closers on many doors throughout industrial and commercial buildings can also assist the flow of traffic. Locations where additional time to clear the opening is advantageous are doors between office and factory/ warehouse facilities, doors to workshops or laboratories, to kitchen and food processing areas, etc. 1900 series door closer applications Regular Arm Parallel Arm This is the only pull-side application where a double lever arm is used. It is the most power-efficient application for a door closer. Sufficient frame, door and/or ceiling clearance must be considered. Since the arm assembly projects directly out from the frame, this application may present an aesthetics issue or be prone to vandalism. This application provides the most appealing design appearance for a surface-mounted door closer having a double lever arm. This also makes it beneficial in vandalism-prone areas. It is on the push side of the door and the arm assembly extends almost parallel to the door. In the closed position, there is very little or no hardware projecting beyond the frame face in most situations. Due to the geometry of the arm it is approximately 25% less power-efficient than a regular arm application. The entire closer and arm assembly are mounted below the frame stop, requiring a top rail of 5-3/8" (137mm) to mount the body. Clearance to the bottom of the closer body from the top of the door is 7-3/8" (187mm). (Based on a 5/8" (16mm) high frame stop.) 5 1900 series door closer applications Parallel Rigid Arm An enhanced variation of the standard parallel arm assembly that is intended for use in heavy traffic areas where auxiliary door stops are installed. Hold open available - specify hand when ordering. Uni Stop™ Arm (Parallel Arm applications only) Uni Stop™ arms combine the features of a doublelever arm overhead door stop/holder with the backcheck feature of the door closer to reduce door stopping shock loads to a minimum. The UNI Stop arm uses a compression spring buffer at the soffit plate/arm shoe that will absorb 30 lbs. of force, 5° prior to the door’s dead stop. Coupled with the door closer’s backcheck feature, this arm provides the most controlled stop available with a surface door closer. There are three different length arm assemblies. Each length is designed for a specific range of door widths to provide precise door control. This further lessens the dead stop impact on the door’s hinges/pivots. 6 1900 series door closer regular arm installation E * Template position for 100° door opening Body mounting holes are spaced 4-1/8" (105mm) horizontally and 1-3/8" (76mm) vertically. Maximum Door Size Wood or Metal Inches (cm) E Minimum Ceiling Clearance Inches (mm) Model Number Interior Exterior Non-Hold Open Hold Open 48" (122) 36" (91) 1902/4 1912/4 — 44" (112) 1905/6 Non-Hold Open Hold Open 1-1/2" (38) 2-1/8" (54) 1915/6 All dimensions are for reference only. Dimensions are given in inches (mm) unless otherwise noted. Door sizing information is based on installation on standard weight doors, 7'0" (2.13m) high x 1-3/4" (44mm) thick, hung on anti-friction hinges and operating under normal conditions. 7 1900 series door closer parallel arm installation * Template position for 130° door opening Body mounting holes are spaced 4-1/8" (105mm) horizontally and 1-3/8" (76mm) vertically. Maximum Door Size Wood or Metal Inches (cm) B Minimum Top Rail with 5/8" (16mm) frame stop Inches (mm) Model Number Interior Exterior Non-Hold Open Hold Open 42" (107) 36" (91) PA1902/4 PA1912/4 — 44" (112) PA1905/6 Without Drop Plate With 1988 Drop Plate 5-3/8" (137) 2-1/2" (64) PA1915/6 All dimensions are for reference only. Dimensions are given in inches (mm) unless otherwise noted. Door sizing information is based on installation on standard weight doors, 7'0" (2.13m) high x 1-3/4" (44mm) thick, hung on anti-friction hinges and operating under normal conditions. 8 1900 series door closer parallel rigid arm * Template position for 130° door opening Body mounting holes are spaced 4-1/8" (105mm) horizontally and 1-3/8" (76mm) vertically. Maximum Door Size Wood or Metal Inches (cm) B Minimum Top Rail with 5/8" (16mm) frame stop Model Number Interior Exterior Non-Hold Open Hold Open 48" (122) 36" (91) PR1902/4 PR1912/4 — 44" (112) PR1905/6 Without Drop Plate With 1988 Drop Plate 5-3/8" (137) 2-1/2" (64) PR1915/6 All dimensions are for reference only. Dimensions are given in inches (mm) unless otherwise noted. Door sizing information is based on installation on standard weight doors, 7'0" (2.13m) high x 1-3/4" (44mm) thick, hung on anti-friction hinges and operating under normal conditions. 9 1900 series door closer uni stop™ arm Body mounting holes are spaced 4-1/8" (105mm) horizontally and 1-3/8" (76mm) vertically. Door Width Inches (cm) B Minimum Top Rail 5/8" (16mm) Frame Stop Without Drop Plate With 1988 Drop Plate 28-32" (71-81) 33-41" (84-104) 5-5/8" (143) 42-48" (107-122) 2-3/4" (70) C Template Position for Hold Open at Listed Angle or Dead Stop at Listed Angle plus 5˚ D Arm Extension Beyond Closer 85° 90° 95° 100° 105° 110° 10" (254) 9-3/8" (238) 8-3/4" (222) 8-1/4" (210) 7-3/4" (197) 7-1/2" (191) 8-7/8" (225) 12-1/4" (311) 11-5/8" (295) 11" (279) 10-1/2" (267) 10" (254) 9-5/8" (244) 10-3/8" (264) 14-5/8" (371) 13-7/8" (352) 13" (330) 12-1/2" (318) 12" (305) 11-1/2" (292) 11-7/8" (302) Maximum Door Size Inches (cm) Model Number Interior Exterior Non-Hold Open Hold Open 28-41” (71-104) 28-36” (71-91) UNI1902/4 UNI1912/4 42-48” (107-122) 37-48” (94-122) UNI1905/6 UNI1915/6 x Specify Door Width All dimensions are for reference only. Dimensions are given in inches (mm) unless otherwise noted. Door sizing information is based on installation on standard weight doors, 7'0" (2.13m) high x 1-3/4" (44mm) thick, hung on anti-friction hinges and operating under normal conditions. 10 1900 series door closer regular arm brackets for non-hold open arms Molded/Bull Nose Trim - #291 Bracket: For use where the door frame has molded or bull nose trim which will not accept a standard non-hold open shoe. The bracket is mortised into the frame rabbet and projects beyond the face of the frame. It will accommodate a frame rabbet up to 2" (51 mm) deep. Molded/Bull Nose Trim - #291A Bracket: This bracket is similar to - but longer than - the 291 bracket. It is designed to accommodate frame rabbets from 2" to 2-7/8" (51 to 73mm) deep. bracket for hold open arms Molded/Bull Nose Trim - #292 Bracket: For use where the door frame has molded or bull nose trim which will not accept a standard hold open shoe. It is mortised into the frame rabbet, and projects beyond the face of the frame. It will accommodate a rabbet up to 2" (51mm) deep. This bracket is used in combination with the standard hold open mounting shoe. 11 1900 series door closer parallel arm brackets for non-hold open arms Standard Installation - #289 Soffit Plate: This soffit plate is supplied standard with parallel arm closers. It can be mounted where the frame soffit is as narrow as 1" (25mm). Narrow Frame/Removable Stop - #297 Soffit Plate: For use where a narrow frame or frame with removable stop does not permit use of the standard soffit plate. This plate may be mounted on the frame soffit or the frame rabbet where the stop does not exceed 5/8" (16mm) in height. All of the screw holes are in a straight line, requiring as little as 1-1/4" (32mm) of frame reveal to mount bracket and maintain good closer arm geometry. Where the frame soffit is as wide as 2" (51mm), this soffit plate may be used to clear weatherstripping that is up to 1-3/8" (35mm) wide and 5/8" (16mm) in height. Flush Transom - 589L Angle Bracket: For use where rabbeted or flush transom conditions prevent installation of a soffit plate. Used in combination with the 289 soffit plate, or it may be used in combination with the 290 soffit plate when it is necessary for the closer arm to clear a separate overhead door holder. 12 Mounting Between Doors - #413A Soffit Bracket: For use where insufficient space between companion doors does not permit use of other soffit plates. This bracket permits mounting of the closer between doors with as little as 4-1/8" (105mm) of header space. Permits closer arm to clear up to a 5/8" (16mm) high stop. Blade/Applied Stop - #299 Soffit Plate: For use where a blade or applied stop does not permit installation of the standard soffit plate. Mounts to either the frame soffit or rabbet. Since this soffit plate projects 7/8" (22mm) less than a standard soffit plate, it requires a minimum frame reveal of 2" (51mm). Permits closer arm to clear up to a 5/8" (16mm) high stop. Extra-Clearance - #290 Offset Soffit Plate: For use where the need for additional clearance prevents use of the standard soffit plate. This plate mounts to the frame soffit to provide up to 2" (51mm) of clearance when a separate overhead door holder is used. Standard mounting requires a 2-5/8" (67mm) wide frame soffit. It may also be used where unusually high frame stops or weatherstripping prevents the use of other soffit plates. 1900 series door closer parallel rigid arm brackets for non-hold open and hold open arms Flush Transom - #293L Angle Bracket: For use where flush transom conditions prevent installation of the standard hold open soffit plate. Used for parallel hold open arms. Standard - #293S Spacer Block: For use where a narrow frame soffit does not provide adequate support for the soffit plate. Supplied as standard with all rigid parallel arm closers. 1-1/2 (38) 1-1/2 (38) Clearance/Support Blade Stop - #891 Spacer Block: For use where the frame has a blade stop and the soffit plate must be mounted on the frame rabbet. This accessory is used in combination with the standard Spacer Block to provide clearance of the blade stop. Narrow Frame - #890 Support Bracket: For use where the frame is narrow, and the soffit plate cannot be mounted directly to the frame soffit or rabbet. Used in combination with the #891 Spacer Block on blade stop frames to provide extra support and needed clearance of the blade stop. closer mounting plates Narrow Top Rail - #1988 Drop Plate: For use where a narrow top rail prevents the closer from being mounted directly to the door surface. 13 1900 series door closer uni stop™ arm brackets Flush Transom - 589L Angle Bracket: For use where rabbeted or flush transom conditions prevent installation of a soffit plate. Used in combination with the 289 soffit plate, or it may be used in combination with the 290 soffit plate when it is necessary for the closer arm to clear a separate overhead door holder. Additional Support - #6190 Reinforcing Bracket: Standard for use with all parallel arm Uni Stop door controls. Provides additional support to the soffit plate on installations with door frame reveals from 1-7/8" to 4-5/8" (48 to 117mm). Wide Frame - #6191 Reinforcing Kit: Optional for use with all parallel arm Uni Stop door controls. Used to support the soffit plate on installations with wide frames. Clamps may be used with or without the spacer block, depending on frame conditions. closer mounting plates Narrow Top Rail - #1988 Drop Plate: For use where a narrow top rail prevents the closer from being mounted directly to the door surface. 14 1900 series door closer corner brackets The following frame-mounted brackets, 1950, 2950 and 964, require the use of a door closer of the opposite hand from the hand of the door. Use the Parallel Arm Sizing Chart to select the correct size of closer to use, when the closer is to be mounted on a corner bracket. 5/8 (16) Ref. 5/8 (16) Ref. 8 (203) 7 (178) 9-3/8 (238) 9-3/8 (238) Corner Mounting, Standard Drop - #1950 Corner Bracket: For use where door is required to open to 180°. Minimum soffit width 1-3/8" (35mm). Corner Mounting, Extra Drop - #2950 Corner Bracket: For use with a separate overhead door holder. Drops closer 1" (25mm) lower than #1950 Standard Drop Corner Bracket to permit mounting of an overhead holder. Permits door openings to 180°. Minimum soffit width 1-3/8" (35mm). 6-1/2 (165) 15 (381) Arched or Circular Top Door - #964 Adjustable Bracket: For opposite hinge side application on arched or circular top doors. This frame-mounted bracket can be adjusted to accommodate virtually any radius of frame. Minimum soffit width 2-1/2" (64mm). This bracket requires the use of a door closer of the opposite hand from that of the door. Arched or Circular Top Door - #974 Offset Adjustable Bracket: For hinge side application on arched or circular top doors. This door-mounted bracket is adjustable to accommodate virtually any radius of frame. Base diameter 3-5/8" (92mm). 15 1900 series door closer adapter plates 16 Dimensions Size Closer Being Replaced Adapter Plate Catalog Number 992/993 A B 1983 5-1/2” (140) 2-5/8” (67) 994 None Required — — 995/996 1986 5-1/2” (140) 2-5/8” (67) 1980 Series Adapter Plate For use when replacing a discontinued old style 990 Series surface closer with a series 1900 Traditional Surface Closer. The plate selected will employ the existing holes in either door or corner bracket. The Series 1900 closer will mount to the plate. These plates can be used to convert regular arm, parallel arm or bracket mount installations. Order by model number. 1900 series door closer parts list regular arm Rod & Shoe 1900-11 Non-Hold Open Main Arm Holder Shoe & Loop 1900-13 Jackscrew 1543R Locknut 455 Friction Disc 1554 (not visible) Hold Open Main Arm Note: Mounting hardware included with all parts ordered Arm Function Complete Arm Assembly Non-Hold Open Y1900-1 Main Arm Main Arm Less Rod & Shoe Main Arm & Rod Less Holder Shoe & Loop Assy. Y1900-1W N/A N/A 1900-3W 1900-1M Hold Open 1900-3 17 1900 series door closer parts list parallel arm Rod & Soffit Plate 1900-15 Main Arm Non-Hold Open Soffit Plate Holder & Loop Assy. 1900-18 (specify hand when ordering) Hold Open Main Arm Note: Mounting hardware included with all parts ordered Arm Function Complete Arm Assembly Non-Hold Open Y1900-5 1900-8R (Right Hand) Hold Open 1900-8L (Left Hand) 18 Main Arm Main Arm Less Rod & Soffit Plate Main Arm & Rod Less Soffit Plate Holder Assy. & Loop Assy. Y1900-1W N/A N/A 1900-3W 1900-1M 1900 series door closer parts list parallel rigid arm assemblies Non-Hold Open Jackscrew (see chart) Locknut 455 Friction Disc 1554 (not visible) Hold Open Note: Mounting hardware included with all parts ordered Arm Function Complete Arm Assembly Jackscrew Non-Hold Open PR1900-5 N/A PR1900-8R (Right Hand) 1543R PR1900-8L (Left Hand) 1543L Hold Open 19 1900 series door closer parts list uni stop™ arm assemblies Main Arm Non-Hold Open Main Arm Hold Open Note: Mounting hardware included with all parts ordered Door Width (cm) Main Arm Length* (mm) 28"- 32" (71 - 81) Non-Hold Open Hold Open 9-1/2" (241) 6130-17 6130-7 33"- 41" (84 - 104) 11" (279) 6130-18 6130-8 42"- 48" (107 - 122) 12-1/2" (318) 6130-19 6130-9 * Center to center length 20 Complete Arm Assembly 1900 series door closer parts list miscellaneous parts Springs Closer Bodies 24BD B/D Spring 56EF E/F Spring 230BC Spring (prior to 1978 model) 230D Spring (prior to 1978 model) 230EF Spring (prior to 1978 model) 1902/4 LAP Size 2-4 body 1905/6 LAP Size 5/6 body screw packs Sex Nuts Thru Bolts & Grommet Nuts SN-134 1-3/4" door TBGN138-38 1-3/8" door SN-214 2-1/4" door TBGN134-38 1-3/4" door TBGN214-38 2-1/4" door fasteners Type Description S = standard; O = optional Arm RA PA PR UNI STOP™ DOOR SDST Self-Drilling Self-Tapping S S S S MS Machine Screw S S S S SN Sleeve Nut O O S S TBGN Thru Bolts & Grommet Nuts O O O O FRAME SDST Self-Drilling Self-Tapping S S S S MS Machine Screw S S S S SN are for use on unreinforced hollow metal doors or to prevent any hollow metal door from collapse/dimpling. They can also be used for thru bolting on wood doors. SN are supplied for 1-3/4" (44mm) thick doors unless specified for 2-1/4" (57mm). TBGN are an alternative to SN for wood doors. TBGN are supplied standard for 1-3/4" (44mm) thick doors. They can be specified for 1-3/8" (35mm) thick doors. 21 1900 series door closer how to order None PA PR UNI - - Regular Arm Parallel Arm Parallel Rigid Arm Uni Stop™ Arm (specify door width) DL - Delayed Action (Regular Non-Hold Open Arm Application Only), Handed 0 - Non-Hold Open 1 - Hold Open 2 thru 4 - 2/4 5 or 6 - 5/6 PA Prefix 19 CLOSER SERIES Note: Contact factory if door weight exceeds 250 lbs. 22 0 ARM FUNCTION 2/4 CLOSER SIZE DL SUFFIXES 689 FINISH (see page 2) 1900 series door closer notes 23 1900 series door closer online literature and templates For the latest information on Yale Locks & Hardware products, visit our website at: www.yalelocks.com Click on the “Product Information” button to find: • • • • • Catalogs Parts manuals Templates Specifications Installation instructions Yale® customers can click on the ebusiness symbol • • • • on the website to register for an ebusiness account to: Check the status of orders Check availability of QuickShip items Track your order and confirm delivery Receive email notification of template changes And More... Or contact us at: U.S.A. Yale Locks & Hardware Address: 225 Episcopal Road, Berlin, CT 06037-4004 Tel: 1-800-438-1951 • Fax: 1-800-338-0965 • www.yalelocks.com Canada: ASSA ABLOY Door Security Solutions Canada Address: 160 Four Valley Drive, Vaughan, Ontario L4K 4T9 Tel: 1-800-461-3007 • Fax: 1-800-461-8989 • www.assaabloy.ca International: ASSA ABLOY Americas International Tel: 1-905-821-7775 • Fax: 1-905-821-1429 • www.assaabloyai.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Uni Stop™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication. Yale Security Inc. reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials. Copyright © 2001, 2014, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited. YALE, with its unique global reach and range of products, is the world’s favorite lock. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. 42066-2/14RE An ASSA ABLOY Group brand
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00 Instance ID : uuid:99e82ecf-b402-6940-8ad8-9c32dbb336af Document ID : adobe:docid:indd:9c9d330c-e2c8-11e0-9ad9-d813192d7b1c Original Document ID : adobe:docid:indd:9c9d330c-e2c8-11e0-9ad9-d813192d7b1c Rendition Class : proof:pdf History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:4AB9267D4A2068118083EE4411DBA192, xmp.iid:4BB9267D4A2068118083EE4411DBA192, xmp.iid:1E37F9B64B2068118083EE4411DBA192, xmp.iid:2233CAA60B2168118F62C79479FC77A5, xmp.iid:9869C66F932068118C14BFB17925C2BC, xmp.iid:D15BC764342068118C14DCC73CBC2AFF, xmp.iid:5E1F5C43362068118C14DCC73CBC2AFF, xmp.iid:B417F4D53A2068118C14DCC73CBC2AFF, xmp.iid:D4A77C513B2068118C14DCC73CBC2AFF, xmp.iid:A0E4311C412068118C14C33F305E8D2B, xmp.iid:76C5C4B9402068118083F83C23F18316, xmp.iid:1FEEE4B22C2068118C14DB03A3E97A1E, xmp.iid:3F962F414E2068118A6DE3C466FD3DF6, xmp.iid:145257216A2068118C149E0F87E0C31A, xmp.iid:824BEBB7322068118A6DE62272C97358, xmp.iid:D67FCDAD352068118A6DE62272C97358, xmp.iid:F9BC1AF4222068118C14C0890833E88B, xmp.iid:ED7B93B57E20681188C6D3BCBBEF5F2B History When : 2011:09:17 14:09:31-04:00, 2011:09:17 14:09:32-04:00, 2011:09:17 14:18:19-04:00, 2011:09:30 08:57:29-04:00, 2011:11:20 10:54:53-05:00, 2011:11:29 12:15:57-05:00, 2011:11:29 12:29:20-05:00, 2011:11:29 13:02:03-05:00, 2011:11:29 13:05:31-05:00, 2012:06:14 08:57:04-04:00, 2012:06:17 06:21:53-04:00, 2012:07:02 17:08:05-04:00, 2012:07:13 08:47-04:00, 2012:08:22 09:43:21-04:00, 2012:09:14 16:03:44-04:00, 2012:09:14 16:24:50-04:00, 2013:06:01 13:42:43-04:00, 2013:06:10 17:13:42-04:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Create Date : 2014:02:08 16:19:42-05:00 Modify Date : 2014:02:08 16:34:57-05:00 Metadata Date : 2014:02:08 16:34:57-05:00 Creator Tool : Adobe InDesign CS5 (7.0) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 8774 bytes, use -b option to extract), (Binary data 8700 bytes, use -b option to extract) Doc Change Count : 148 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 24 Creator : Adobe InDesign CS5 (7.0)EXIF Metadata provided by EXIF.tools