User Manual
Smart-Ashley® Smart-Ashley® YDL100SF USER MANUAL 1 YDL100SF Name and Caution 2 Autuentication Type 3 Notifications 4 Factory Reset 5 Caution 6 Operation 1. YDL100SF Name and Caution DIP S/W Display status Emergency Tap Tap S/W B S/W A Battery Connector Battery Keypad ·Password Card Reader Card Authentication Manual Lever Bluetooth 4.0[BLE] · Mobile key Authentication · d-key / i-Key 1 2 3 4 Mechanical Key Cover 1. Tap‘A’ 3. DIP S/W (Long) YDL100SF - Mobile Phone Connect (Short) Password Change Mode 2. Tap‘B’ (Long) Card Registraion (short) Card Delete DIP Switch #1 (Left / Right Door Select) DIP Switch #2 1K2L On/Off DIP Switch #3 1K2L Master / Slave DIP Switch #4 출입통제기 연동 On/ Off - Default Settings : Left / 1K2L Off / 1k2L Master/ Access Control Device Off 2. Authentication Smart PhoneBluetooth 4.0 (BLE) iOS 8 / Android 4.3.1 (Jellybean) or higher i-key service available with internet connection (LTE, WCDMA, EDGE, GSM) ★i-Key 발급 : 무제한 / D-Key 발급 : 200 개 Password (User / Guest) Support from 4 to 16 digits Support from 4 to 16 digits Only use 1 time ★마그넷은 기본 구성품에 포함되지 않습니다. Card (Basic: 2) Available to register 200 Key tags for maximum 3. Notifications When ringing the sound to replace the battery When you open the door with password or card, if the alarm sounds and yellow LED flickers, please replace the battery Replace the battery Green Authentication (Registration) type input waiting When lightening on, authentication (opening) success Red Yellow Authentication Failure Low voltage warning / Overlapped registration Authentication / (locking) success End Voltage warning Trespass Alert Remove the batteries and press Tab S/W for 2 seconds. Then, insert new batteries. Caution The battery period can be different depending manufacturer, the date of manufacture, and environment Please check regularly because the liquid flowed out from the batteries may damage the appliance. (Every 6 months) 4. Factory Reset Tap‘A’and‘B’for 5 seconds at the same time and the melody sounds and YDL100SF becomes factory reset ① Set User Password“0000” ② Disable Guest PIN code ③ Delete all Card ④ Delete all d-Keys ⑤ Unregister i-Key admin 5. Caution ★ Safety precautions ·Please carefully manage to prevent the others know the password and change it periodically ·When you go out, please make sure that you locked the door completely ·Please note that the inserted battery exactly match the polarity (+/-) of the product (When inserting the battery in reverse or differently, there may cause leakage or rupture) ·If the battery life is over, please replace all the batteries and do not mix the battery in use and the used battery · When cleaning the product, please don t use water, benzene, and alcohol but use with soft and dry cloth ·When the melody for replacing the battery alarms at first, please replace all batteries with new one in a week 6. Operation YDL100SF Installation How to operate Password Touch ① Touch Out-body panel to activate the key pad Please refer to attached installation guide to complete installation Turn In-body lever counter clockwise or clockwise in order that ② Press 2 Random Keys ③ After the full keys appear, press existing Password number ④ After pressing the existing code, press 'V' key ★ Operate Password to control doorlock ★ Factory default Password is ‘0000’ the deadbolt is correctly fit. If the handle does not correctly turn, please check installation guide How to Change Password How to register guest Password Touch ① Press‘A’button the top right side for 2 second ② Press existing Password (Default: 0000) then press 'V' ★ Password can be saved up to 4~16 digit ③ Press new Password and 'V' ④ Press new Password again to verify and 'V' (Buzzer) ① Touch Out-body panel to activate the keypad ② Press 'V' for 2 seconds ③ Press existing Password (USER Password) and 'V' ④ Press new guest on Password (4~16 digits) and 'V' ★ If Guest Password is set, Password will be deleted after one time usage ★ To delete Guest Password, follow above step 1,2,3 then wait for 5 second ★ Guest Password can be saved up to 4 ~ 16 digit ★ Guest Password operation will be same with 6.B 6. Operation How to register Card How to Operation Card Touch ① Tap S/W 'B' button for 2 seconds ② Press existing Password and 'V' button ③‘C’will appear from the Key pad ④ Contact your Card on the touch panel ⑤ LED will stay for 5 second for registration ★ Up to 200 Card can be saved ★ Registration mode will be finished, after LED is turned off (5 second) ★ If magnet sensor is connected and Auto-Lock On is in use, Trespass Alert is activated. How to delete Card ① Tap S/W 'B' button for 1 seconds ② Press existing Password and 'V' button ③‘C’will appear from 5,6,7,8 ④ Contact your Card on the touch panel ⑤ LED will stay for 5 second for registration ① Touch keypad to activate ② Contact your card on touch panel to open the door 6. Operation How to register/delete/operate d-Key & i-Key for more information please check App guide How to delete d-key / i-key Registering d-Key Registering i-Key ★ Up to 200 d-key can be saved ★ Register YDL100SF in Admin account ① Set the factory initialization to delete all date ② Delete selectively or delete all using App ① Press A button on the top right side for 1 second ② Follow app menu ① Tap S/W 'A' button for 1 seconds ② Follow i-Key registration to set d-key procedure from App menu How to Operate d-key / i-key ★ To use "Shaking Authentication", it is only available in Android and App should run (It will be supported in iPhone in the future) ·Operate with App · Shake to open feature Trespass Alert is deactivated when any of the following authentication methods (Password/Card/D-Key/i-Key) is used. Touch Touch ① Touch keypad ② Open app from the SMAT PHONE. ① Touch keypad When Auto-Lock is off, doors are closed by touching Keypad/Key box from outside. ② Shake smartphone to open door Press saved d-key or i-key button to open door Smart-Ashley® YDL100SF USER MANUAL Support 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel +82.2.6488.3062 E-mail Sales@virditech.com FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: 1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. “CAUTION : Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC radio frequency exposure limit.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : ko-KR Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : 예지 Title : 170510_keylesskey 유저매뉴얼131dw Create Date : 2017:06:12 17:34:16+09:00 Creator Tool : Microsoft® Word 2010 Modify Date : 2017:06:12 19:24:22+09:00 Metadata Date : 2017:06:12 19:24:22+09:00 Producer : Microsoft® Word 2010 Document ID : uuid:0f67b7b9-5a41-4fa1-95fd-d35172d273f5 Instance ID : uuid:06218386-eac8-4ea9-acf1-8d92c92c2cee Page Count : 9 Author : 예지EXIF Metadata provided by EXIF.tools