036-21103-003 Rev. A (0403) ® TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER 50 HZ H*RA018S78 THRU H*RA036S78 (1 PH) H*RA036S50 THRU H*RA060S50 (3PH) (1.5 THRU 5 NOMINAL TONS) DESCRIPTION The HRA Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom matched with one of UPG’s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces and air handlers. FEATURES • QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins. • COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. • PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. • DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight. • LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. • TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. • LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. • LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. • EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. • SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. • FACTORY TESTED - to verify system operation and control functioning before shipment. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21103-003 Rev. A (0403) PHYSICAL AND ELECTRICAL DATA - 1 & 3 Phase MODEL H1RA018S78 H1RA024S78 H1RA030S78 H1RA036S78 H1RA036S50 H1RA048S50 H1RA060S50 Unit Supply Voltage Normal Voltage Range 230 – 1 – 50 380/415 – 3 – 50 207 to 253 342 to 455 1 Minimum Circuit Ampacity 9.8 14.6 20.4 20.8 7.3 10.8 13.3 Max. Qvercurrent Device Amps 2 15 25 35 35 15 15 20 Recip Recip Recip Recip Recip Recip Recip 7.4 11.3 15.2 15.5 5.2 7.2 9.2 Compressor Type Compressor Amps Rated Load Locked Rotor Crankcase Heater Fan Motor Amps Rated Load 90 82 39 53 79 No No No No No .5 .5 1.8 1.8 .8 1.8 1.8 18 18 18 18 22 22 Rated HP 1/12 1/12 1/4 1/4 1/4 1/3 1/3 Nominal RPM 970 970 900 900 1,100 1,075 1,075 Nominal CFM 1,650 1,650 2,350 2,350 2,250 3,200 3,300 8.00 8.00 9.15 9.15 9.15 15.72 23.58 Face Area Sq. Ft. Coil 65 No 18 Fan Diameter Inches Fan Motor 53 No Rows Deep 1 1 1 1 1 1 1 Fin / Inches 14 14 16 16 18 18 18 Liquid Line OD 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line OD 3/4 3/4 3/4 3/4 3/4 7/8 7/8 3 - 13 3 - 14 3 - 15 4 - 11 4 - 11 7 - 10 9 - 12 Charge Per Foot, Oz. 0.66 0.66 0.68 0.68 0.68 0.70 0.70 Operating Weight Lbs. 118 123 135 137 137 206 228 Unit Charge (Lbs. - Oz.) 3 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. 3. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, refer to publication 035-15893-60* All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. UNIT MODEL H1RA 018S78 024S78 030S78 036S78 036S50 048S50 060S50 REFRIGERANT CONNECTION LINE SIZE DIMENSIONS (INCHES) A1 17 17 19 19 19 27 39 B C Liquid 35 35 35 35 35 37 37 23 23 23 23 23 27 27 3/8” Vapor 3/4” 7/8” 1. Including fan guard 2 Unitary Products Group 036-21103-003 Rev. A (0403) Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 & 3 Phase Additional R-22 Charge / Orifice Size for Various Matched Systems Outdoor Unit (H1RA) Unit 018S78 Orifice(s)1 Factory R-22 Charge, lbs-oz 3 - 13 024S78 G2FD024S14,17 61 G2FD030S17 65 G2FD036S17 75 G2FD036S21 75 G2FD042S21 78 G2FD048S21,24 78 G2FD060S24 90 036S78 036S50 048S50 51 57 69 71 71 84 3 - 14 3 - 14 4 - 11 4 - 11 7 - 10 9 - 12 Coil Orifice2 Indoor Coil 030S78 060S50 System Orifice + Additional Charge, Oz 51 + 0 57 + 0 69 + 0 69 + 3 71 + 0 71 + 0 71 + 2 71 + 2 71 + 4 84 + 0 90 + 0 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING 3 UNIT MODEL MODEL ELECTRIC 2 HEAT KW W COIL MODEL RATED CFM NET MBH KW SEER SEER/TXV1 EER TOTAL SENS. 1 PHASE HRA / NAH H1RA018S78 N1AHB1293 5,8,10,15,18 17 G2FD024S17 650 18.1 12.9 1.86 -- -- -- H1RA024S78 N1AHB1293 5,8,10,15,18 17 G2FD030S17 850 23.4 16.8 2.87 -- -- -- N1AHB1293 5,8,10,15,18 17 G2FD030S17 1000 28.9 20.0 3.45 -- -- -- N1AHB1293 5,8,10,15,18 17 G2FD036S17 1000 29.6 20.6 3.57 -- -- -- N1AHB1293 5,8,10,15,18 17 G2FD036S17 1250 33.5 25.2 3.83 -- -- -- N1AHB1293 5,8,10,15,18 17 G2FD036S17 1200 33.6 24.9 3.81 -- -- -- 3.87 H1RA030S78 H1RA036S78 3 PHASE HRA / NAH H1RA036S50 N1AHB1293 5,8,10,15,18 17 G2FD036S21 1200 34.4 25.5 N1AHC1693 5,8,10,15,20 21 G2FD042S21 1250 35.1 25.9 3.93 H1RA048S50 N1AHC1693 5,8,10,15,18 21 G2FD048S21 1600 48.8 35.9 4.82 -- -- -- H1RA060S50 N1AHD2093 5,8,10,15,18 24 G2FD060S24 1900 60.5 43.0 6.29 -- -- -- 1 PHASE HRA / FRP (SINGLE PHASE) H1RA018S78 F2RP024N93 5,7.5,10 18 -- 650 18.1 12.9 1.86 -- -- -- H1RA024S78 F2RP024N93 5,7.5,10 18 -- 850 23.4 16.8 2.87 -- -- -- H1RA030S78 F2RP036N93 5,7.5,10,15 21 -- 1000 29.6 20.6 3.57 -- -- -- H1RA036S78 F2RP036N93 5,7.5,10,15 21 -- 1250 34.3 25.6 3.86 -- -- -- 3 PHASE HRA / FRP (SINGLE PHASE) H1RA036S50 F2RP036N93 10,15 21 -- 1200 34.4 25.5 3.87 -- -- -- H1RA048S50 F2RP048N93 10,15 24 -- 1600 48.8 35.9 4.82 -- -- -- H1RA060S50 F2RP060N93 10,15 24 -- 1900 60.5 43.0 6.29 -- -- -- Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit. Single phase units require single phase 2HK heaters — Three phase units require three phase 2HK heaters. (29) indicates 460 volt use only. 3. G2FD coils available with a factory installed horizontal drain pan. Replace “S” with “H” in the model number. — = Not Applicable. 2. Unitary Products Group 3 036-21103-003 Rev. A (0403) COOLING PERFORMANCE MODEL TEMP. H1RA018S78 H1RA024S78 H1RA030S78 H1RA036S78 H1RA036S50 H1RA048S50 H1RA060S50 AIR TEMP ON CONDENSER SUCT. T/P @ COMPR. PSIG 75°F MBH 95°F KW MBH 115°F KW MBH 125°F KW MBH KW 35 61.5 13.1 1.36 13.1 1.36 10.6 1.46 9.3 1.52 40 68.5 14.8 1.42 14.8 1.42 12.8 1.55 10.6 1.61 45 76.0 16.5 1.48 16.5 1.48 13.7 1.62 12.2 1.69 50 84.0 18.4 1.55 18.4 1.55 15.2 1.71 13.7 1.78 35 61.5 21.3 1.59 17.7 1.93 14.7 2.14 13.3 2.23 40 68.5 24.1 1.68 20.1 2.04 16.7 2.27 15.1 2.38 45 76.0 26.7 1.77 22.3 2.16 18.9 2.40 17.1 2.53 50 84.0 29.6 1.85 24.9 2.27 21.1 2.55 19.4 2.67 35 61.5 28.0 2.31 24.4 2.65 20.1 2.86 18.0 2.96 40 68.5 31.5 2.44 27.5 2.78 22.8 3.02 23.4 3.31 45 76.0 35.1 2.52 30.7 2.91 25.9 3.17 23.4 3.48 50 84.0 38.9 2.62 34.2 3.04 28.8 3.34 26.3 3.48 35 61.5 30.6 3.14 27.0 3.48 23.1 3.79 21.0 3.89 40 68.5 34.4 3.28 30.4 3.64 26.1 3.98 23.7 4.10 45 76.0 38.3 3.42 33.9 3.81 29.1 4.17 26.6 4.30 50 84.0 38.9 2.62 34.2 3.04 28.8 3.34 26.3 3.48 35 61.5 29.6 3.24 27.8 3.52 25.1 3.73 23.4 3.78 40 68.5 33.2 3.37 31.2 3.68 28.2 3.91 26.4 3.97 45 76.0 36.9 3.51 34.7 3.84 31.4 4.10 29.3 4.16 50 84.0 40.7 3.65 38.2 4.00 34.6 4.28 32.4 4.36 35 61.5 43.2 4.17 39.1 4.87 34.4 5.50 31.9 5.87 40 68.5 48.1 4.37 43.6 5.11 38.5 5.80 35.8 6.22 45 76.0 53.2 4.58 48.3 5.35 42.8 6.11 39.8 6.57 50 84.0 58.4 4.79 53.2 5.60 47.2 6.41 44.0 6.91 35 61.5 50.6 5.23 48.7 5.73 45.2 6.11 42.7 6.24 40 68.5 55.6 5.37 54.1 5.97 50.8 6.44 48.4 6.61 45 76.0 60.9 5.48 59.7 6.19 56.7 6.76 54.5 6.98 50 84.0 66.3 5.58 65.6 6.40 62.8 7.08 60.8 7.35 1.For condensing unit only. Does not include effect of evaporator motor power or heat. 2.Performance based on 15” superheat and 15" sub-cooling at condensing unit. a.Increase capacity 1% for each 2...increase in sub-cooling. b.Decrease capacity 1% for each 2 decrease in sub-cooling. 3.Sub-cooling in excess of 20...may result in excessively high condensing temperature with air on condenser above 115° Maximum recommended condensing temperature is 140..F. 4 Unitary Products Group 036-21103-003 Rev. A (0403) ACCESSORIES Refer to Price Manual for specific model numbers. SOUND RATINGS Compressor Blanket - Designed to further reduce the normal operating sound. UNIT MODEL SOUND RATINGS DECIBELS Hard Start Kit (Single Phase Units) - provides required starting torque for use with thermal expansion valve. 018 76 024 78 030 82 036 82 048 82 060 80 Outdoor Thermostat - 2TD06700124 - Consists of an adjustable outdoor thermostat and relay in a vented enclosure. It provides additional second stage control of the supplemental resistance heat.(Balance Point Control) TYPICAL INSTALLATION - H*RA018S78 THRU 036S78 (1 PH) & H*RA 036S50 THRU 060S50 (3 PH) 60” OVERHEAD CLEARANCE MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE THERMOSTAT WEATHERPROOF DISCONNECT SWITCH TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10” CLEARANCE COIL AREA TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. Unitary Products Group SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL 5 036-21103-003 Rev. A (0403) TYPICAL FIELD WIRING - 1 PH APPLICATION (018S78 - 036S78) ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 230-1-50 POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. C Y R G W Y R G W CONTACTOR TERMINALS GND. LUG COIL * ROOM THERMOSTAT CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. TYPICAL FIELD WIRING - 3 PH APPLICATION (036S50 - 060S50) ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 380/415-3-50 POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK C Y R G W Y R G W * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. CONTACTOR TERMINALS GND. LUG COIL CONDENSING UNIT * ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. 6 Unitary Products Group 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA018S78A INDOOR COIL MODEL NO. G2FD024S17 CONDENSING ENTERING AIR TEMPERATURE 75 85 95 105 115 125 IDCFM 500 650 800 ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 18.3 18.1 16.5 18.4 18.2 17.2 18.4 18.3 17.8 S.C. 10.6 10.8 10.5 11.0 11.6 11.9 11.4 12.4 13.3 K.W 1.55 1.55 1.53 1.71 1.71 1.69 1.68 1.67 1.66 T.C. 17.8 17.2 15.4 18.0 17.5 16.1 18.2 17.8 16.8 13.1 S.C. 10.6 10.7 10.2 11.3 11.7 11.6 12.0 12.8 K.W 1.76 1.74 0.95 1.95 1.93 1.90 1.95 1.93 1.90 T.C. 17.3 16.3 14.2 17.6 16.8 15.0 17.9 17.3 15.8 S.C. 10.6 10.5 9.8 11.6 11.8 11.4 12.5 13.1 12.9 K.W 1.79 1.75 1.71 1.95 1.92 1.88 1.92 1.89 1.85 T.C. 16.0 14.7 12.6 16.5 15.3 13.3 17.0 15.9 14.1 S.C. 10.0 10.0 9.2 11.4 11.4 10.7 12.7 12.8 12.2 K.W 1.99 1.94 1.90 2.19 2.14 2.09 2.19 2.14 2.09 12.3 T.C. 14.6 13.1 11.0 15.3 13.8 11.7 16.0 14.4 S.C. 9.4 9.5 8.5 11.2 11.0 10.0 12.9 12.5 11.5 K.W 2.01 1.94 1.90 2.18 2.12 2.07 2.16 2.10 2.04 T.C. 13.0 11.1 9.3 13.7 11.6 9.9 14.3 12.1 10.4 S.C. 9.4 8.5 7.8 11.1 10.0 9.2 12.7 11.5 10.6 K.W 2.11 2.04 1.98 2.28 2.21 2.15 2.26 2.19 2.13 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB1293 G2FD024S17 1.00 1.00 1.00 1.00 1.00 1.00 F2RP024N93 Unitary Products Group 7 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA024S78A INDOOR COIL MODEL NO. G2FD030S17 IDCFM 650 850 1050 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 26.4 25.3 24.0 26.6 25.7 24.6 26.7 26.1 25.2 75 S.C. 15.4 15.6 15.4 16.2 16.7 16.8 16.9 17.8 18.2 K.W 2.15 2.11 2.08 2.17 2.13 2.10 2.18 2.15 2.12 T.C. 25.4 23.9 21.8 25.7 24.6 22.8 26.1 25.2 23.7 18.1 85 95 105 115 125 S.C. 15.3 15.1 14.4 16.4 16.6 16.2 17.4 18.2 K.W 2.31 2.26 1.16 2.33 2.28 2.23 2.36 2.31 2.26 T.C. 24.4 22.5 19.6 24.9 23.4 20.9 25.4 24.3 22.2 S.C. 15.3 14.6 13.4 16.6 16.6 15.7 17.9 18.5 17.9 K.W 2.47 2.40 2.31 2.50 2.44 2.35 2.53 2.47 2.39 T.C. 22.5 20.1 17.6 23.2 21.1 18.6 23.9 22.1 19.6 S.C. 14.7 13.8 12.7 16.4 15.9 14.7 18.1 17.9 16.8 K.W 2.62 2.53 2.44 2.66 2.57 2.47 2.70 2.61 2.51 T.C. 20.6 17.7 15.6 21.5 18.8 16.3 22.4 19.8 16.9 S.C. 14.2 13.0 11.9 16.3 15.2 13.8 18.3 17.3 15.6 K.W 2.76 2.65 2.56 2.81 2.70 2.59 2.86 2.74 2.62 T.C. 17.8 15.2 13.3 18.7 15.9 14.0 19.5 16.7 14.7 S.C. 13.3 12.4 11.4 15.4 14.3 13.1 17.4 16.1 14.7 K.W 2.89 2.78 2.69 2.94 2.82 2.72 2.99 2.85 2.75 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB1293 G2FD030S17 1.00 1.00 1.00 1.00 1.00 1.00 F2RP024N93 8 Unitary Products Group 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA030S78A INDOOR COIL MODEL NO. G2FD030S17 IDCFM 650 850 1050 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 26.4 25.3 24.0 26.6 25.7 24.6 26.7 26.1 25.2 75 S.C. 15.4 15.6 15.4 16.2 16.7 16.8 16.9 17.8 18.2 K.W 2.39 2.35 2.32 2.53 2.49 2.46 2.56 2.53 2.50 T.C. 25.4 23.9 21.8 25.7 24.6 22.8 26.1 25.2 23.7 18.1 85 95 105 115 125 S.C. 15.3 15.1 14.4 16.4 16.6 16.2 17.4 18.2 K.W 2.67 2.62 1.40 2.82 2.76 2.71 2.93 2.88 2.83 T.C. 24.4 22.5 19.6 24.9 23.4 20.9 25.4 24.3 22.2 S.C. 15.3 14.6 13.4 16.6 16.6 15.7 17.9 18.5 17.9 K.W 2.71 2.64 2.55 2.86 2.80 2.71 2.91 2.85 2.77 T.C. 22.5 20.1 17.6 23.2 21.1 18.6 23.9 22.1 19.6 S.C. 14.7 13.8 12.7 16.4 15.9 14.7 18.1 17.9 16.8 K.W 2.98 2.89 2.80 3.14 3.05 2.95 3.27 3.18 3.08 T.C. 20.6 17.7 15.6 21.5 18.8 16.3 22.4 19.8 16.9 S.C. 14.2 13.0 11.9 16.3 15.2 13.8 18.3 17.3 15.6 K.W 3.00 2.88 2.80 3.17 3.05 2.95 3.24 3.12 3.00 T.C. 17.8 15.2 13.3 18.7 15.9 14.0 19.5 16.7 14.7 S.C. 13.3 12.4 11.4 15.4 14.3 13.1 17.4 16.1 14.7 K.W 3.13 3.02 2.93 3.30 3.18 3.08 3.37 3.23 3.13 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB1293 G2FD030S17 1.00 1.00 1.00 N1AHB1293 G2FD036S17 F2RP036N93 Unitary Products Group 1.02 1.03 1.03 1.02 1.03 1.03 9 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA036S50A INDOOR COIL MODEL NO. G2FD036S17 IDCFM 1100 1250 1400 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 38.6 36.0 33.4 39.0 36.4 33.9 39.4 36.8 34.3 75 S.C. 26.0 25.7 25.3 25.8 26.4 27.1 25.6 27.2 28.8 K.W 3.20 3.12 3.04 3.30 3.34 3.38 2.99 3.15 3.31 T.C. 36.4 33.7 31.0 36.9 34.2 31.4 37.5 34.7 31.9 27.5 85 95 105 115 125 S.C. 24.8 24.5 24.2 25.2 25.5 25.9 25.5 26.5 K.W 3.56 3.48 1.88 3.75 3.75 3.75 3.53 3.61 3.69 T.C. 34.2 31.3 28.5 34.8 31.9 28.9 35.5 32.5 29.4 S.C. 23.6 23.3 23.0 24.5 24.6 24.7 25.4 25.9 26.3 K.W 3.52 3.44 3.36 3.74 3.70 3.66 3.55 3.55 3.55 T.C. 31.9 29.0 26.0 32.8 29.6 26.5 33.6 30.3 27.0 S.C. 22.5 22.2 21.9 23.9 23.7 23.5 25.3 25.2 25.1 K.W 3.88 3.80 3.72 4.19 4.11 4.03 4.09 4.01 3.93 T.C. 29.7 26.6 23.5 30.7 27.4 24.0 31.7 28.1 24.5 S.C. 21.3 21.0 20.7 23.2 22.8 22.3 25.2 24.5 23.9 K.W 3.84 3.76 3.68 4.18 4.06 3.94 4.11 3.95 3.79 T.C. 27.6 24.3 21.0 28.1 24.9 21.7 28.6 25.5 22.4 S.C. 20.6 20.0 19.4 22.7 21.6 20.5 24.8 23.2 21.7 K.W 3.92 3.92 3.92 4.38 4.26 4.14 4.43 4.19 3.95 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW NAHB1293 G2FD036S17 1.00 1.00 1.00 NAHB1293 G2FD036S21 1.02 1.02 1.02 NAHC1693 G2FD042S21 1.04 1.04 1.03 1.02 1.02 1.02 F2RP036N93 10 Unitary Products Group 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA036S78A INDOOR COIL MODEL NO. G2FD036S17 IDCFM 1050 1250 1450 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 38.7 36.8 35.0 39.1 34.7 35.6 39.4 32.5 36.2 75 S.C. 23.4 23.5 23.4 24.4 24.8 24.8 25.4 26.1 26.2 K.W 3.30 3.25 3.21 3.59 3.54 3.50 3.48 3.43 3.39 T.C. 37.4 34.8 31.9 37.7 34.1 32.6 38.1 33.4 33.4 25.5 85 95 105 115 125 S.C. 23.5 24.0 22.2 24.7 25.2 23.9 25.9 26.4 K.W 3.74 3.65 1.95 4.06 4.00 3.90 4.00 3.94 3.84 T.C. 36.0 32.7 28.7 36.4 33.5 29.6 36.7 34.3 30.5 S.C. 23.6 24.5 21.0 25.0 25.6 22.9 26.4 26.7 24.8 K.W 3.80 3.67 3.51 4.09 3.99 3.83 3.99 3.92 3.76 T.C. 32.6 29.1 25.5 33.2 29.9 26.3 33.9 30.7 27.2 S.C. 22.6 22.1 19.6 24.3 23.6 21.5 26.1 25.2 23.3 K.W 4.17 4.00 3.85 4.53 4.36 4.21 4.49 4.32 4.17 T.C. 29.2 25.5 22.3 30.1 26.3 23.1 31.0 27.0 23.8 S.C. 21.5 19.6 18.2 23.6 21.6 20.0 25.7 23.6 21.8 K.W 4.16 3.95 3.81 4.50 4.27 4.12 4.45 4.19 4.04 T.C. 25.5 22.4 19.6 26.2 22.8 20.0 26.9 23.1 20.4 S.C. 20.3 18.8 17.4 22.3 20.5 18.9 24.3 22.2 20.3 K.W 4.29 4.12 3.99 4.65 4.43 4.29 4.61 4.35 4.20 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB1293 G2FD036S17 1.00 1.00 1.00 1.02 1.02 1.01 F2RP036N93 Unitary Products Group 11 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA048S50A INDOOR COIL MODEL NO. G2FD048S21 IDCFM 1400 1450 1500 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 66.1 57.0 47.9 63.5 55.8 48.1 61.0 54.6 48.3 75 S.C. 34.2 34.3 34.3 34.7 35.1 35.6 35.1 36.0 36.8 K.W 4.49 4.83 4.70 4.99 5.09 4.96 4.98 4.84 4.70 T.C. 58.8 51.6 44.5 57.7 51.2 44.7 56.5 50.8 45.0 35.2 85 95 105 115 125 S.C. 33.2 33.1 32.9 33.9 34.0 34.1 34.6 34.9 K.W 4.93 5.03 4.80 5.60 5.57 5.42 5.50 5.34 5.18 T.C. 51.5 46.3 41.1 51.8 46.6 41.4 52.1 46.9 41.7 S.C. 32.1 31.9 31.6 33.1 32.9 32.6 34.1 33.8 33.6 K.W 5.36 5.22 5.08 5.67 5.51 5.35 5.47 5.29 5.11 T.C. 44.2 40.9 37.7 45.9 42.0 38.0 47.6 43.0 38.4 S.C. 31.1 30.7 30.2 32.4 31.7 31.1 33.6 32.8 32.0 K.W 5.82 5.67 5.53 6.16 5.99 5.81 5.99 5.79 5.59 T.C. 36.9 35.6 34.3 40.0 37.4 34.7 43.1 39.1 35.1 S.C. 30.1 29.5 28.9 31.6 30.6 29.6 33.1 31.7 30.3 K.W 5.76 5.61 5.46 6.12 5.93 5.75 5.96 5.74 5.52 T.C. 39.5 35.3 31.1 39.6 35.4 31.3 39.7 35.6 31.6 S.C. 28.2 27.9 27.5 27.1 28.8 30.5 25.9 29.7 33.6 K.W 6.11 5.93 5.75 6.43 6.23 6.03 6.23 6.01 5.79 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW NAHC1693 G2FD048S21 1.00 1.00 1.00 1.00 1.00 1.00 F2RP048N93 12 Unitary Products Group 036-21103-003 Rev. A (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA060S50A INDOOR COIL MODEL NO. G*FD060S24A IDCFM 1650 1900 2150 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 65.0 62.4 59.6 65.8 62.8 60.0 66.6 63.3 60.5 75 S.C. 41.8 41.5 41.0 44.7 44.0 43.6 47.5 46.5 46.1 K.W 5.40 5.36 5.28 5.81 5.76 5.69 5.62 5.56 5.50 T.C. 63.9 60.7 56.5 64.7 61.4 57.5 65.4 62.1 58.5 S.C. 41.8 41.1 39.8 44.7 43.7 42.5 47.5 46.4 45.3 K.W 6.11 6.04 5.91 6.57 6.49 6.38 4.41 4.34 4.27 T.C. 62.8 59.1 53.5 63.5 60.0 55.0 64.3 60.8 56.5 S.C. 41.8 40.7 38.6 44.6 43.5 41.5 47.5 46.2 44.4 K.W 6.21 6.12 5.94 6.63 6.53 6.39 6.45 6.33 6.23 T.C. 60.6 55.3 49.3 61.5 56.6 50.7 62.4 58.0 52.2 85 95 105 115 125 S.C. 40.9 39.4 36.8 44.0 42.4 39.8 47.1 45.3 42.9 K.W 6.92 6.74 6.57 7.38 7.22 7.05 7.24 7.10 6.93 T.C. 58.5 51.5 45.1 59.6 53.3 46.5 60.6 55.1 47.9 S.C. 40.1 38.2 35.0 43.4 41.3 38.2 46.8 44.4 41.4 K.W 7.03 6.76 6.59 7.44 7.22 7.02 7.25 7.08 6.84 T.C. 52.9 47.7 40.4 54.2 48.5 41.9 55.5 49.4 43.5 S.C. 38.7 36.7 32.8 42.0 39.4 35.8 45.4 42.1 38.9 K.W 7.31 7.09 6.84 7.78 7.53 7.29 7.64 7.36 7.13 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW NAHD2093 G2FD060S24 1.00 1.00 1.00 1.00 1.00 1.00 F2RP060N93 Unitary Products Group 13 036-21103-003 Rev. A (0403) MATCHING INDOOR COMPNENTS ADD-ON COILS - FOR FURNACE APPLICATION G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW) AIR HANDLERS N1AH MODULAR BLOWER F2RP FAN COIL UNITS (UPFLOW, HORIZONTAL) G2FD* COIL P6UH FURNACE 14 Unitary Products Group 036-21103-003 Rev. A (0403) NOTES Unitary Products Group 15 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2003. All rights reserved. Unitary Product Group 036-21103-003 Rev. A (0403) Supersedes: 036-21103-002 Rev. A (1101) 5005 York Drive Norman OK 73069
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2003:05:05 11:40:59-05:00 Create Date : 1999:05:10 13:18:07Z Page Count : 16 Page Mode : UseThumbs Producer : Acrobat Distiller 4.05 for Windows Author : sardom Mod Date : 2003:05:05 11:40:59-05:00 Creation Date : 1999:05:10 13:18:07Z Metadata Date : 2003:05:05 11:40:59-05:00 Creator : sardom Title : 036-21103-003-A-0403.fmEXIF Metadata provided by EXIF.tools