York H Ra018 Thru 060 Users Manual Y TG HRA
H*RA036 THRU 090 to the manual 6e6f8e61-b422-4805-8403-e3bc37221f30
2015-02-02
: York H-Ra018-Thru-060-Users-Manual york-h-ra018-thru-060-users-manual-455114 york pdf
Open the PDF directly: View PDF
.
Page Count: 20
| Download | |
| Open PDF In Browser | View PDF |
036-21121-002 Rev. A (0602) ® TECHNICAL GUIDE MODELS: 018 - 060 (1 PH & 3 PH) MODELS: 076 - 090 (3 PH) FI ED T O ARI C M ER -C PL RY UN I NI N G G W IT H OI IT TA Y D ON MA N U F A C T U R AS AIR NI TI O ER R RT IF RI I CA T F U I P M EN T O EQ E C A T IO NS I ON S E C 10 S T A NDA R D 2 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. The 10 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces and air handlers. WARRANTY SPLIT-SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*RA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*RA036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) C DESCRIPTION LISTED Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. Single Phase Units: 5-year limited parts warranty. 5-year limited compressor warranty. Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES • QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins. • COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. • PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. • DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted desert sand finish insure less fading when exposed to sunlight. • LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. • TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. • LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. • LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. • EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. • SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. • U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21121-002 Rev. A (0602) Physical and Electrical Data - 1 Phase MODEL H1RA018S06 H1RA024S06 H2RA030S06 H2RA036S06 H1RA042S06 H1RA048S06 H3RA060S06 Unit Supply Voltage 208/230 – 1 – 60 Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 12.5 15.6 17.5 21.5 26.1 30.1 37.3 20 25 30 35 40 45 60 Recip Recip Recip Recip Recip Recip Scroll B 9.6 12.1 13.6 16.1 19.8 23 28.8 160 Max. Overcurrent Device Amps 2 Compressor Type 3 Rated Load Compressor Amps Locked Rotor Crankcase Heater Fan Motor Amps Rated Load Fan Diameter Inches Fan Motor 57 73 82 97 110 No No No No No No 0.5 0.5 0.5 1.4 1.4 1.3 1.3 18 18 18 18 18 22 22 Rated HP 1/12 1/12 1/12 1/4 1/4 1/4 1/4 Nominal RPM 1,100 1,100 1,100 1,100 1,100 850 850 Nominal CFM 1,850 1,850 1,900 2,750 2,750 3,250 3,300 8.00 8.00 9.15 9.15 12.58 15.72 15.72 Face Area Sq. Ft. Coil 54 No Rows Deep 1 1 1 1 1 1 1 Fin / Inches 14 14 18 18 18 18 22 Liquid Line OD 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line OD 5/8 5/8 3/4 3/4 3/4 7/8 7/8 3-6 3 - 11 3 - 14 3 - 15 5-4 7-5 6-2 0.66 0.66 0.68 0.68 0.68 0.70 .070 118 123 135 137 161 176 188 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz. 4 4 Operating Weight Lbs. Physical and Electrical Data - 3 Phase H1RA H1RA H1RA H1RA H1RA H1RA H1RA H1RA H1RA H1RA H1RA H1RA 036S25 042S25 048S25 060S25 076S25 090S25 036S25 042S46 048S46 060S46 076S46 090S46 MODEL Unit Supply Voltage Normal Voltage Range 1 Minimum Circuit Ampacity Max. Overcurrent Device Amps 2 Compressor Type 3 Compressor Amps Rated Load Locked Rotor Crankcase Heater Fan Motor Amps Rated Load Fan Diameter Inches 432 to 504 15.0 17.4 17.3 21.3 25.8 37.7 8.0 8.4 8.3 10.8 13.0 25 30 30 35 40 50 15 15 15 15 20 Scroll Scroll Dual Recip Recip Recip 16.0 18.9 29.4 5.8 6.1 6.1 8.0 9.5 14.0 125 146 260 40 39 39 67 73 128 No No No Yes No No No No No Yes 1.3 1.3 2.2 4.6 .8 .8 .7 .8 1.2 2.3 Recip Recip Scroll 10.9 12.8 11.7 78 78 78 No No 1.4 1.4 B 25 ScrollB Recip B 18.1 B Dual 18 18 22 22 24 24 18 18 22 22 24 24 1/4 1/4 1/4 1/3 3/4 1/4 1/4 1/5 1/4 1/3 3/4 Nominal RPM 1,100 1,100 850 850 1100 1100 1,100 1,100 850 850 1100 1100 Nominal CFM 2,750 2,750 3,250 3,450 4000 5000 2,750 2,750 3,250 3,450 4000 5000 9.15 12.58 15.72 23.58 18.0 22.5 9.15 12.58 15.72 23.58 18.0 22.5 Face Area Sq. Ft. Coil 460 - 3 - 60 187 to 252 1/4 Rated HP Fan Motor 208/230 – 3 – 60 Rows Deep 1 1 1 1 2 2 1 1 1 1 2 2 Fin / Inches 18 18 18 18 16 16 18 18 18 18 16 16 Liquid Line OD 3/8 3/8 3/8 3/8 1/2 1/2 3/8 3/8 3/8 3/8 1/2 1/2 Vapor Line OD 3/4 3/4 7/8 7/8 1-1/8 1-1/8 3/4 3/4 7/8 7/8 1-1/8 1-1/8 3 - 15 5-4 7-5 9-7 12-3 15-3 3 - 15 5-4 7-5 9-7 12-3 15-3 Unit Charge (Lbs. - Oz.) 4 4 .68 .68 .70 .70 1.26 1.26 .68 .68 .70 .70 1.26 1.26 Operating Weight Lbs. 170 176 206 228 219 368 170 176 206 228 219 368 Charge Per Foot, Oz. 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot valve. 2 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING CAPACITY - With Air Handler Coils COOLING NET MBH SEER RATED ELECTRIC W CFM TOTAL SENS. W/O TXV HEAT KW 1 PH 10 SEER AC WITH N1AH / G2FD 2,5,8,10 17 G2FD024S17 650 19.0 14.1 10.50 2,5,8,10 17 G2FD024S17 800 24.4 18.1 10.50 2,5,8,10 17 G2FD030S17 850 25.0 18.5 10.60 5,8,10,15,19 17 G2FD030S17 1000 29.0 21.5 10.30 5,8,10,15,19 17 G2FD036S17 1000 30.0 22.2 10.50 5,8,10,15,19 17 G2FD036S17 1200 33.8 25.0 10.00 5,8,10,15,19 17 G2FD046S17 1200 34.4 25.5 10.15 5,8,10,15,20 21 G2FD042S21 1400 39.5 29.2 10.00 5,8,10,15,20 21 G2FD048S21 1450 41.0 30.3 10.10 5,8,10,15,20 21 G2FD048S21 1600 46.0 34.0 10.10 8,10,15,20,25,30 24 G2FD060S24 1600 47.0 34.8 10.40 8,10,15,20,25,30 24 G2FD060S24 1800 56.0 40.2 10.50 3 PH 10 SEER AC WITH N1AH / G2FD 10,15 21 G2FD036S17 1200 33.8 25.0 10.00 10,15 21 G2FD042S21 1400 40.0 30.1 10.00 10,15 21 G2FD042S21 1400 39.5 29.2 10.00 10,15 24 G2FD048S21 1450 41.0 30.3 10.10 10,15 21 G2FD048S21 1600 46.0 34.0 10.10 10,15,29 24 G2FD048S24 1600 24.6 34.0 10.10 10,15,29 24 G2FD048S24 1600 46.0 34.0 10.10 10,15,29 24 G2FD060S24 1750 58.5 39.8 10.00 AIR HANDLER UNIT MODEL H1RA018S06 H1RA024S06 H2RA030S06 H2RA036S06 H1RA042S06 H1RA048S06 H3RA060S06 H1RA036 S(25,46) H1RA042S(25,46) H1RA048S(25,46) H1RA060S(25,46) H1RA018S06 H1RA024S06 H2RA030S06 H2RA036S06 H1RA042S06 H1RA048S06 H3RA060S06 H1RA036 S(25,46) H1RA042S(25,46) H1RA048S(25,46) H1RA060S(25,46) MODEL N1AHB0806 N1AHB0806 N1AHB0806 N1AHB1206 N1AHB1206 N1AHB1206 N1AHB1206 N1AHC1606 N1AHC1606 N1AHC1606 N1AHD2006 N1AHD2006 N1AHB1246 N1AHB1246 N1AHC1646 N1AHC1646 N1AHC1646 N1AHD2046 N1AHD2046 N1AHD2046 F2RC/F2FC024 F2RP/F2FP018 F2RP/F2FP024 F2RP/F2FP024 F2RP/F2FP030 F2RP/F2FP030 F2RP/F2FP036 F2RC/F2FC036 F2RP/F2FP036 F2RP/F2FP042 F2RP/F2FP042 F2FP048 F2FP048 F2FP060 F2FP060 F2RC/F2FC036 F2RP/F2FP042 F2FP048 F2FP048 F2FP060 COIL1 MODEL 2 1 PH 10 SEER AC / F2RP / RC / FC 4,5 5,8,10 18 650 2,5,8 18 650 5,8,10 18 650 5,8,10 18 800 5,8,10,15 18 800 5,8,10,15 18 1000 5,8,10,15,19 21 1000 5,8,10,15 21 1200 5,8,10,15,19 21 1200 5,8,10,15 21 1200 5,8,10,15 21 1400 5,8,10,15,20,25 24 1400 5,8,10,15,20,25 24 1600 5,8,10,15,20,25 24 1600 5,8,10,15,20,25 24 1800 3 PH 10 seer AC with F2RP / FP 5,8,10,15 21 1200 5,8,10,15 21 1400 5,8,10,15,20,25 24 1400 5,8,10,15,20,25 24 1600 5,8,10,15,20,25 24 1750 H1RA076S25,46 K4EV090 10,16,26,36 H1RA090S25,46 K4EV090 10,16,26,36 3 PH 10 seer AC WITH K4EV 6 22 -2600 22 -- 3280 SEER + TXV3 EER - 9.80 9.55 9.65 9.45 9.65 9.20 9.30 9.00 9.15 9.50 9.70 9.35 - 9.20 9.05 9.00 9.15 9.50 9.50 9.50 10.25 17.4 17.4 17.4 23.4 23.6 28.4 28.0 33.6 34.4 34.4 39.5 40.5 45.5 46.5 56.0 12.9 12.3 12.9 17.3 17.5 21.0 20.0 21.5 25.2 25.2 28.9 30.0 33.7 34.4 41.0 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.20 10.15 10.00 10.00 10.00 10.00 10.00 - 9.00 9.00 9.00 9.00 9.10 9.50 9.00 9.10 9.30 9.20 9.00 9.20 9.15 9.70 9.15 33.6 39.0 40.5 45.5 58.5 25.2 29.2 30.4 33.7 39.8 10.00 10.00 10.00 10.00 10.00 - 9.10 9.00 9.00 9.15 9.80 73.5 53.8/ 89.0 -- -- -- -- -- -- 10.00 9.63/ 9.30 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2 Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters. 3 TXV = Use 1TV700 Series Kit. 4 To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same. 5 FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard. 6 H*BA-(T,W)090 is field convertible to two stage operation. Its IPLV = 11.2. — = Not Applicable. Unitary Products Group 3 036-21121-002 Rev. A (0602) COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** UNIT MODEL CFM RANGE (MIN.-MAX.) H1RA018S06 575 725 H1RA024S06 700 900 H2RA030S06 875 1125 H2RA036S06 1050 1350 W COIL MODEL 14,17 14 17 14,17 14 14,17 17 14 14,17 14 14 17,21 17 21 14,17 14 14 17,21 14,17 17 14 17 14 14 17,21 17 21 14 17,21 17 14 21 14 17,21 17 21,24 17 21 14 17,21 17 21,24 14 17 21 21 17 G1FA024S14,17 G1FA030S14 G1HD024 G1NA024S17G G1UA024S14,17 G1UA030S14 G2FD024S14,17 G2FD030S17 G2FD035S14 G1FA024S14,17 G1FA030S14 G1FA036S14 G1FA036S17,21 G1HD024 G1HD036 G1NA030S17H G1NA030S21B G1UA024S14,17 G1UA030S14 G1UA036S14 G1UA036S17,21 G2FD024S14,17 G2FD030S17 G2FD035S14 G2FD036S17 G1FA030S14 G1FA036S14 G1FA036S17,21 G1HD036 G1NA030S17K G1NA030S21M G1UA036S14 G1UA036S17,21 G2FD030S17 G2FD035S14 G2FD036S21 G1FA036S14 G1FA036S17,21 G1FA048S17 G1FA048S21,24 G1HD036 G1HD048 G1NA036S17J G1NA036S21C G1UA036S14 G1UA036S17,21 G1UA048S17 G1UA048S21,24 G2FD035S14 G2FD036S17 G2FD036S21 G2FD042S21 G2FD046S17 COOLING RATED CFM 650 650 655 650 650 650 650 650 650 850 800 800 850 820 800 800 800 850 800 800 850 800 850 850 850 1000 1000 1000 1000 1000 1050 1000 1000 1000 1000 1000 1200 1200 1200 1200 1200 1165 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 NET MBH TOTAL SENS. 18.0 13.3 19.0 14.1 18.5 13.7 18.0 12.5 18.0 13.3 19.0 14.1 19.0 14.1 19.4 14.4 19.4 14.4 23.8 17.6 24.4 18.1 24.0 18.1 25.0 18.5 23.2 17.2 24.4 18.1 23.6 17.5 23.6 17.5 23.8 17.6 24.4 18.1 24.0 18.5 25.0 18.5 24.4 18.5 25.0 18.5 25.0 18.9 25.6 18.9 28.0 20.7 29.2 20.3 29.0 21.5 29.6 21.9 29.0 20.4 29.0 20.4 29.2 20.3 29.0 21.5 29.0 21.5 29.0 21.5 30.0 22.2 33.6 24.9 33.6 24.9 35.0 25.9 36.0 26.6 34.4 25.5 34.8 25.8 34.4 25.5 34.4 25.5 33.6 24.9 33.6 24.9 35.0 25.9 36.0 26.6 33.4 24.7 33.8 25.0 33.8 25.0 34.4 25.5 34.4 25.5 SEER + TXV W/O TDR 10.00 10.50 10.50 10.00 10.00 10.50 10.50 10.50 10.50 10.00 10.50 10.00 10.00 10.00 10.60 10.00 10.00 10.00 10.50 10.00 10.00 10.50 10.60 10.60 10.70 10.00 10.25 10.45 10.00 10.00 10.00 10.25 10.45 10.30 10.30 10.50 10.00 10.00 10.30 10.40 10.00 10.00 10.00 10.00 10.00 10.00 10.30 10.40 10.00 10.00 10.00 10.15 10.15 SEER + TXV1 + TDR* - EER 9.20 9.80 10.00 9.40 9.20 9.80 9.80 9.90 9.90 9.15 9.55 9.00 8.95 8.80 9.80 9.00 9.00 9.15 9.55 9.00 8.95 9.55 9.65 9.65 9.70 9.30 9.40 9.45 9.55 9.30 9.20 9.40 9.45 9.45 9.45 9.65 9.10 9.10 9.40 9.40 8.90 8.95 9.20 9.30 9.10 9.10 9.40 9.40 9.10 9.20 9.20 9.30 9.30 For Notes See Page 5. 4 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued) FURNACE** UNIT MODEL CFM RANGE (MIN.-MAX.) H1RA036S25,46 1050 1350 H1RA042S06 1225 1575 H1RA042S25,46 1225 1575 H1RA048S06 1400 1800 H1RA048S25,46 1400 1800 H3RA060S06 1600 2100 H1RA060S25,46 1525 1975 H1RA076S25,46 H1RA090S25,46 2500-3000 2500-3000 W COIL MODEL 17,21 21,24 17 21 17,21 21,24 17 21 17 21,24 21,24 21 21 17 21,24 21,24 21 17 21,24 24 21,24 21,24 21 21 21,24 21,24 21 17 21,24 17 21,24 21,24 21 17 21,24 21,24 17 21,24 24 21,24 21 21,24 21,24 21,24 21 24 21,24 24 24 21,24 24 21,24 24 35 35 G1FA036S17,21 G1FA048S21,24 G1NA036S17J G1NA036S21C G1UA036S17,21 G1UA048S21,24 G2FD036S17 G2FD036S21 G1FA048S17 G1FA048S21,24 G1FA060S21,24 G1HD048 G1NA036S21C G1NA048S21D G1UA048S17 G1UA048S21,24 G1UA060S21,24 G2FD042S21 G2FD046S17 G2FD048S21,24 G2FD060S24 G1FA048S21,24 G1FA060S21,24 G1NA036S21C G1NA048S21D G1UA048S21,24 G1UA060S21,24 G2FD042S21 G2FD046S17 G2FD048S21,24 G1FA048S17 G1FA048S21,24 G1FA060S21,24 G1HD048 G1HD060 G1NA048S21D G1UA048S17 G1UA048S21,24 G1UA060S21,24 G2FD046S17 G2FD048S21,24 G2FD060S24 G1FA048S21,24 G1NA048S21D G1UA048S21,24 G2FD048S21,24 G1FA060S21,24 G1HD060 G1NA048S21D G1NA060S24T G1UA060S21,24 G2FD060S24 G2FD061H24 G1FA060S21,24 G1NA060S24T G1UA060S21,24 G2FD060S24 G2FD090S35*** G2FD090S35*** COOLING RATED CFM 1200 1200 1200 1200 1200 1200 1200 1200 1380 1400 1400 1390 1400 1400 1380 1400 1400 1400 1380 1450 1450 1400 1400 1400 1400 1400 1400 1400 1380 1450 1500 1600 1600 1600 1600 1400 1500 1600 1600 1500 1600 1600 1600 1400 1600 1600 1800 2000 1500 1800 1800 1800 2000 1750 1750 1750 1750 3200 4000 NET MBH TOTAL SENS. 33.6 24.9 36.0 26.6 34.4 25.5 34.4 25.5 33.6 24.9 36.0 26.6 33.8 25.0 33.8 25.0 40.0 30.2 41.0 30.3 42.0 31.0 40.5 30.0 40.0 28.3 40.5 28.6 40.0 30.2 41.0 30.3 42.0 31.1 39.5 29.2 40.0 29.6 41.0 30.3 42.0 31.0 41.0 30.3 42.0 31.0 40.0 28.3 40.5 28.6 41.0 30.3 42.0 31.1 39.5 29.2 40.0 29.6 41.0 30.3 44.5 33.5 45.5 33.7 47.0 34.8 45.5 33.7 46.5 34.4 46.5 34.4 44.5 33.5 45.5 33.7 47.0 34.8 44.5 32.9 46.0 34.0 47.0 34.0 45.5 33.5 46.5 34.4 45.5 33.5 46.0 34.0 56.0 40.2 55.5 40.0 51.0 34.8 55.0 39.8 56.0 40.2 56.0 40.2 57.0 40.9 58.5 39.8 57.5 39.1 58.5 39.8 58.5 39.8 73.5 52.9 90.0 64.8 SEER + TXV W/O TDR 10.00 10.40 10.00 10.00 10.00 10.40 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.10 10.10 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.10 10.00 10.00 10.40 10.00 10.20 10.00 10.00 10.00 10.40 10.00 10.10 10.40 10.00 10.00 10.00 10.10 10.50 10.50 10.00 10.50 10.50 10.50 10.50 10.00 10.00 10.00 10.00 --- SEER + TXV1 + TDR* --- EER 9.10 9.40 9.20 9.30 9.10 9.40 9.20 9.20 9.05 9.25 9.45 9.05 9.15 9.15 9.05 9.25 9.45 9.00 9.05 9.15 9.50 9.25 9.45 9.15 9.15 9.25 9.45 9.00 9.05 9.15 9.15 9.45 9.70 9.50 9.65 9.50 9.15 9.45 9.70 9.15 9.50 9.70 9.45 9.50 9.45 9.50 9.35 9.15 8.90 9.25 9.35 9.35 9.35 10.25 10.00 10.25 10.25 10.00 9.35 1 TXV = Use 1TV700 Series Kit. Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. *** This coil is for upflow application only. * Unitary Products Group 5 036-21121-002 Rev. A (0602) COOLING PERFORMANCE MODEL SUCT. T/P @ COMPR. AIR TEMP ON CONDENSER 75°F TEMP. PSIG MBH 35 H1RA018S06 H1RA024S06 H2RA030S06 H2RA036S06 H1RA036 S(25,46) H1RA042S06 H1RA042S(25,46) 61.5 95°F 115°F KW MBH KW MBH KW 16.2 1.66 13.1 1.84 11.0 1.96 AIR TEMP ON CONDENSER SUCT. T/P @ COMPR. MODEL TEMP. PSIG 75°F 95°F 115°F MBH KW MBH KW MBH KW 4.18 32.3 4.63 27.0 4.94 35 61.5 39.9 40 68.5 43.6 4.21 36.7 4.73 31.4 5.14 45 76.0 47.6 4.26 41.1 4.84 34.9 5.32 5.48 40 68.5 17.7 1.67 14.9 1.88 12.8 2.04 45 76.0 19.3 169 16.7 1.92 14.2 2.11 50 84.0 20.8 1.70 18.5 1.96 15.9 2.18 50 84.0 51.1 4.28 45.5 4.94 39.0 35 61.5 21.0 2.23 17.0 2.46 14.2 2.63 35 61.5 49.4 4.15 43.8 5.13 38.2 6.34 40 68.5 22.9 2.24 19.3 2.52 16.5 2.74 40 68.5 54.0 4.19 48.2 5.14 42.3 6.35 45 76.0 25.0 2.27 21.6 2.58 18.3 2.83 45 76.0 58.4 4.27 52.4 5.25 46.3 6.47 50 84.0 26.8 2.28 23.9 2.63 20.5 2.92 50 84.0 62.7 4.32 56.9 5.38 50.2 5.61 35 61.5 25.1 2.68 20.3 2.97 17.0 3.17 35 61.5 54.4 4.46 50.5 4.74 46.3 5.08 40 68.5 27.4 2.70 23.1 3.04 19.7 3.30 40 68.5 60.1 4.44 56.0 4.83 51.6 5.18 45 76.0 29.9 2.74 25.8 3.10 21.9 3.41 45 76.0 65.8 4.53 61.6 4.92 56.9 5.26 50 84.0 32.1 2.75 28.6 3.17 24.5 3.51 50 84.0 71.9 4.62 67.5 5.01 62.6 5.36 35 61.5 30.5 3.28 24.7 3.64 20.6 3.88 35 61.5 77.4 5.06 63.4 6.08 50.6 7.35 40 68.5 33.3 3.31 28.1 3.72 24.0 4.04 40 68.5 84.5 5.21 69.2 6.23 55.4 7.49 45 76.0 36.4 3.35 31.4 3.80 26.7 4.18 45 76.0 91.8 5.37 75.3 6.38 60.3 7.64 50 84.0 39.1 3.36 34.8 3.88 29.9 4.31 50 84.0 99.4 5.54 81.7 6.55 65.6 7.80 35 61.5 35.8 3.83 28.9 4.25 24.2 4.53 35 61.5 84.0 8.28 72.9 9.11 61.7 9.87 40 68.5 39.1 3.86 32.9 4.34 28.2 4.72 40 68.5 92.5 8.50 80.8 9.41 68.9 10.26 45 76.0 42.6 3.90 36.8 4.53 31.3 4.87 45 76.0 101.3 8.73 89.0 9.72 76.5 10.66 50 84.0 45.8 3.93 40.8 4.63 35.0 5.03 50 84.0 110.4 8.95 97.5 10.03 84.4 11.08 H1RA048S06 H1RA048S(25,46) H3RA060S06 H1RA060S(25,46) H1RA076S(25,46) H1RA090S(25,46) NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 15° superheat and 15° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling. b. Decrease capacity 1% for each 2° decrease in sub-cooling. 3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°F. Maximum recommended condensing temperature is 140°F. DIMENSIONS - 1 Phase C A B UNIT MODEL A1 17 17 19 19 25 27 27 018 024 030 036 042 048 060 REFRIGERANT CONNECTION LINE SIZE DIMENSIONS (INCHES) B 35 35 35 35 35 37 37 C 23 23 23 23 23 27 27 Liquid 3/8” Vapor 5/8” 5/8” 3/4” 3/4” 3/4” 7/8” 7/8” DIMENSIONS - 3 Phase UNIT MODEL 036 042 048 060 076 090 1 6 REFRIGERANT CONNECTION LINE SIZE DIMENSIONS (INCHES) A1 19 25 27 39 26 32 B 35 35 37 37 43 43 C 23 23 27 27 32 32 Liquid 3/8” 3/8 3/8” 3/8” 1/2 1/2 Vapor 3/4 3/4 7/8 7/8 1-1/8 1-1/8 Including Fan guard. Unitary Products Group 036-21121-002 Rev. A (0602) ACCESSORIES* SOUND RATINGS* Refer to Price Manual for specific model numbers. Hard Start Kit - Provides increased starting torque for areas with low voltage. UNIT MODEL SOUND RATINGS DECIBELS Compressor Blanket - Designed to further reduce the normal compressor operating sound. Refer to price pages for specific match-ups. 018 7.6 024 7.8 030 8.2 036 8.2 042 8.2 048 8.2 060 8.0 Off Cycle Timer Delay - Provides a 5-minute off cycle to prevent rapid recycling of the compressor. Room Thermostats - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 1 Heat Stage only, manual, mechanical thermostat. Add subbase for 1H/1C. 076 -- 090 9.0 *Rated in accordance with ARI Standard 270. 1H/1C, manual change-over electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. TYPICAL INSTALLATION 60” OVERHEAD CLEARANCE MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE THERMOSTAT WEATHERPROOF DISCONNECT SWITCH TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10” CLEARANCE COIL AREA NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. Unitary Products Group TO INDOOR COIL SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL 7 036-21121-002 Rev. A (0602) TYPICAL FIELD WIRING - 1 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING POWER WIRING 24 VOLT CONTROL WIRING 208/230-1-60 CONTROL WIRING MINIMUM 18 GA. WIRE 230-1-50 FACTORY WIRING (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. C Y R G W Y R G W CONTACTOR TERMINALS GND. LUG COIL * ROOM THERMOSTAT CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. TYPICAL FIELD WIRING - 3 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-3-60 460-3-60 POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. GND. LUG C Y R G W Y R G W CONTACTOR TERMINALS COIL CONDENSING UNIT * ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. 8 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA018S06 INDOOR COIL MODEL NO. G1FA024S14,17 CONDENSER ENTERING AIR TEMPERATURE ID CFM ID DB (°F) 550 85 80 650 70 85 80 750 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 20.6 19.7 18.1 20.7 19.8 18.5 20.8 19.8 18.9 S.C. 12.7 12.8 12.3 13.3 13.5 13.4 13.7 13.8 14.0 K.W 1.68 1.65 1.64 1.72 1.71 1.70 1.75 1.74 1.73 75 85 95 105 115 125 T.C. 20.6 19.3 17.4 20.9 19.6 18.0 21.1 19.8 18.4 S.C. 12.7 12.6 11.9 13.5 13.4 13.1 14.1 14.0 13.8 K.W 1.58 1.54 1.53 1.62 1.59 1.58 1.65 1.63 1.62 T.C. 19.0 17.5 15.5 19.5 18.0 16.1 19.8 18.2 16.5 S.C. 12.8 12.4 11.5 13.7 13.3 12.8 14.5 14.1 13.6 K.W 1.97 1.91 1.90 2.02 1.96 1.95 2.05 2.00 1.99 T.C. 18.4 16.6 14.2 18.9 17.1 15.0 19.2 17.4 15.4 S.C. 12.5 11.8 10.7 13.6 12.8 12.0 14.4 13.7 12.8 K.W 1.82 1.77 1.75 1.88 1.82 1.80 1.91 1.86 1.83 T.C. 16.3 14.5 11.9 16.9 15.0 12.7 17.2 15.2 13.1 S.C. 12.3 11.2 10.0 13.5 12.4 11.2 14.3 13.2 12.0 K.W 2.24 2.19 2.14 2.31 2.24 2.19 2.35 2.28 2.22 10.8 T.C. 14.3 12.3 9.7 14.9 13.0 10.5 15.2 13.1 S.C. 12.0 10.6 9.3 13.3 11.9 10.4 14.2 12.8 11.2 K.W 2.66 2.61 2.53 2.74 2.66 2.58 2.79 2.70 2.61 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM Multipliers for determining the performance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHB0806 G2FD024S17 1.06 1.06 0.99 0.97 0.97 0.99 G1FA030S14 1.06 1.06 0.99 G1HD024 1.03 1.03 0.95 G1NA024S17G 1.00 0.94 0.98 F2RC/F2FC024 G1UA024S14,17 1.00 1.00 1.00 G1UA030S14 1.06 1.06 0.99 G2FD024S14,17 1.06 1.06 0.99 G2FD030S17 1.08 1.08 1.00 G2FD035S14 1.08 1.08 1.00 Unitary Products Group 9 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA024S06 INDOOR COIL MODEL NO. G1FA024S14, 17 ID CFM 600 800 1000 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB (°F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 28.3 25.9 22.7 21.4 28.7 25.1 24.4 21.8 27.5 26.6 24.5 20.9 75 S.C. 16.9 16.9 15.4 17.0 17.7 16.8 17.0 17.8 17.1 18.0 17.3 17.3 K.W 2.04 1.94 1.78 1.78 2.05 1.87 1.89 1.80 1.97 1.98 1.89 1.72 85 95 105 115 125 T.C. 28.5 26.0 22.8 21.4 28.9 25.2 24.4 21.8 27.7 26.7 24.6 20.9 S.C. 17.5 17.5 16.0 17.6 18.5 17.6 17.9 18.7 18.0 19.0 18.2 18.3 K.W 2.25 2.14 1.95 1.95 2.28 2.06 2.07 1.96 2.18 2.18 2.07 1.88 T.C. 26.9 24.5 21.4 20.1 27.3 23.7 23.0 20.6 26.2 25.2 23.0 19.8 S.C. 17.4 17.4 15.9 17.5 18.5 17.6 17.9 18.8 18.1 19.0 18.3 18.4 K.W 2.42 2.28 2.06 2.06 2.44 2.20 2.20 2.08 2.34 2.32 2.21 1.99 T.C. 24.7 22.4 19.5 18.3 24.8 21.6 20.9 18.6 23.8 22.8 21.1 17.9 S.C. 16.8 16.8 15.3 16.9 17.9 16.9 17.3 17.9 17.6 18.4 17.6 17.5 K.W 2.52 2.37 2.15 2.14 2.54 2.30 2.29 2.17 2.43 2.43 2.30 2.07 T.C. 22.0 19.9 17.4 16.3 22.2 19.3 18.6 16.9 21.2 20.4 18.8 16.2 S.C. 15.8 15.7 14.3 15.8 17.0 16.2 16.2 16.7 16.7 17.5 16.8 16.1 K.W 2.60 2.45 2.23 2.20 2.63 2.36 2.37 2.25 2.51 2.50 2.37 2.17 T.C. 19.4 17.5 15.3 14.2 19.5 16.9 16.3 15.1 18.6 17.9 16.5 14.6 S.C. 14.7 14.7 13.3 14.6 16.0 15.4 15.1 15.4 15.9 16.6 15.9 14.6 K.W 2.68 2.53 2.31 2.26 2.71 2.43 2.44 2.33 2.59 2.57 2.44 2.27 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. T.C. S.C. KW Air Handler Coil N1AHB0806 G2FD024S14,17 0.98 0.98 0.91 N1AHB0806 G2FD030S17 1.00 1.00 0.93 F2RP/F2FP024 0.94 0.94 0.93 F2RP/F2FP030 0.94 0.95 0.93 G1FA030S14 0.98 0.98 0.91 G1HD024 0.93 0.93 0.94 G1HD036 0.98 0.98 0.89 G1NA030S17H 0.94 0.95 0.94 G1NA030S21B 0.944 0.946 0.939 G1UA024S14,17 0.95 0.95 0.93 G1UA030S14 0.98 0.98 0.91 G1UA036S17,21 1.00 1.00 1.00 G2FD024S14,17 0.98 0.98 0.91 G2FD030S17 1.00 1.00 0.93 G2FD035S14 1.00 1.00 0.93 G2FD036S17 1.02 1.02 0.94 MDD30BSD 0.94 0.95 0.94 10 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RA030S06 INDOOR COIL MODEL NO. G1FA036S17,21 CONDENSER ENTERING AIR TEMPERATURE ID CFM ID DB (°F) 800 85 80 1000 75 70 85 80 1200 75 70 85 80 75 70 ID WB (°F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 33.9 31.1 28.7 25.6 34.4 31.5 29.1 26.0 34.7 31.8 29.4 26.3 75 85 95 105 115 125 S.C. 20.5 20.6 19.7 20.7 21.4 21.4 20.6 21.6 22.2 22.2 21.4 22.5 K.W 2.69 2.64 2.59 2.52 2.78 2.73 2.68 2.61 2.86 2.81 2.76 2.69 T.C. 33.0 30.2 27.8 24.9 33.4 30.6 28.2 25.5 33.7 30.9 28.5 25.9 S.C. 20.6 20.7 19.9 20.9 21.6 21.7 20.9 22.1 22.6 22.6 21.7 23.0 K.W 2.87 2.79 2.72 2.64 2.94 2.88 2.82 2.75 3.02 2.96 2.90 2.84 T.C. 31.3 28.7 26.4 23.7 31.7 29.0 26.7 24.1 31.9 29.2 27.1 24.4 S.C. 20.3 20.4 19.5 20.8 21.5 21.5 20.7 21.6 22.4 22.5 21.7 22.7 K.W 3.07 2.98 2.91 2.81 3.15 3.07 3.00 2.92 3.25 3.16 3.10 2.99 T.C. 29.3 26.7 24.6 22.0 29.5 27.0 25.0 22.4 29.7 27.2 25.2 23.1 S.C. 19.9 19.9 19.2 20.0 21.0 21.0 20.1 21.1 22.1 22.1 21.1 22.2 K.W 3.27 3.17 3.09 2.98 3.37 3.27 3.19 3.07 3.45 3.37 3.28 3.19 T.C. 26.9 24.5 22.6 20.3 27.1 24.8 22.9 21.0 27.2 25.1 23.1 21.4 S.C. 19.2 19.1 18.3 19.1 20.3 20.3 19.3 20.2 21.2 21.2 20.2 20.6 K.W 3.48 3.37 3.26 3.14 3.57 3.47 3.36 3.26 3.67 3.56 3.46 3.35 T.C. 24.5 22.3 20.7 18.6 24.7 22.6 20.9 19.6 24.7 23.0 21.1 19.7 S.C. 18.5 18.3 17.4 18.2 19.6 19.6 18.4 19.3 20.3 20.3 19.3 19.0 K.W 3.69 3.57 3.43 3.30 3.77 3.67 3.53 3.45 3.89 3.75 3.64 3.51 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHB1206 G2FD030S17 1.00 1.00 1.00 N1AHB1206 G2FD036S17 1.03 1.03 1.01 F2RP/F2FP030 0.98 0.98 0.97 F2RP/F2FP036 0.97 0.93 1.01 G1FA030S14 0.97 0.96 0.98 G1FA036S14 1.01 0.94 1.01 G1HD036 1.02 1.02 1.01 G1NA030S17K 1.00 0.95 1.02 G1NA030S21M 1.00 0.95 1.03 G1UA036S14 1.01 0.94 1.01 G1UA036S17,21 1.00 1.00 1.00 G2FD030S17 1.00 1.00 1.00 G2FD035S14 1.00 1.00 1.00 G2FD036S21 1.03 1.03 1.01 MDD30MSD 1.00 0.95 1.03 Unitary Products Group 11 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H2RA036S06, H1RA036S(25,46) INDOOR COIL MODEL NO. G1FA036S17,21 ID CFM 1150 1250 1350 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 38.3 36.1 34.4 37.9 36.3 34.6 38.0 36.4 34.9 75 S.C. 24.0 23.7 24.0 24.1 24.5 24.7 24.7 25.3 25.2 K.W 3.19 3.14 3.09 3.23 3.20 3.14 3.26 3.23 3.18 85 95 105 115 125 T.C. 36.9 34.6 32.2 36.9 34.9 32.6 37.0 35.2 33.0 S.C. 24.2 23.7 22.9 24.7 24.6 23.9 25.3 25.5 24.8 K.W 3.45 3.39 3.30 3.50 3.44 3.36 3.53 3.49 3.40 T.C. 35.5 33.2 30.0 35.8 33.6 30.4 36.0 34.0 31.0 S.C. 24.3 23.6 21.9 25.4 24.9 23.6 26.0 25.6 24.4 K.W 3.71 3.63 3.52 3.76 3.69 3.58 3.80 3.75 3.62 T.C. 33.2 30.4 26.7 33.4 30.8 27.2 33.6 31.3 27.7 S.C. 23.7 22.5 20.7 24.5 23.6 21.9 25.4 24.6 23.0 K.W 3.97 3.84 3.71 4.02 3.91 3.77 4.06 3.96 3.81 T.C. 31.0 27.6 23.5 31.1 28.2 24.2 31.3 28.5 24.4 S.C. 23.1 21.3 19.6 23.9 22.6 20.7 24.8 23.7 21.6 K.W 4.22 4.06 3.90 4.29 4.13 3.94 4.33 4.18 4.00 T.C. 28.7 24.8 20.2 28.9 25.6 21.1 29.0 25.7 21.0 S.C. 22.5 20.2 18.4 23.2 21.6 19.6 24.2 22.7 20.2 K.W 4.47 4.28 4.09 4.56 4.35 4.11 4.60 4.40 4.19 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM Multipliers for determining the performance with other indoor sections. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHB1206 G2FD036S17 1.01 1.00 1.00 N1AHB1246 G2FD036S17 1.00 1.00 0.98 N1AHB1206 G2FD046S17 1.02 1.02 1.00 N1AHB1246 G2FD046S21 1.02 1.02 1.00 F2RC/F2FC036 1.00 0.86 1.00 F2RC/F2FC036 1.00 0.86 1.00 F2RP/F2FP036 1.02 1.01 1.00 G1FA048S21,24 1.07 1.07 1.04 F2RP/F2FP042 12 1.02 1.01 1.01 G1NA036S17J 1.02 1.02 1.01 G1FA036S14 1.00 1.00 1.00 G1NA036S21C 1.02 1.02 1.00 G1FA048S17 1.04 1.04 1.01 G1UA036S17,21 1.00 1.00 1.00 G1FA048S21,24 1.07 1.07 1.04 G1UA048S21,24 1.07 1.07 1.04 G1HD036 1.02 1.02 1.05 G2FD036S17 1.01 1.00 1.00 G2FD046S17 1.02 1.02 1.00 G2FD036S21 1.01 1.00 1.00 G1HD048 1.04 1.04 1.05 G1NA036S17J 1.02 1.02 1.01 G1NA036S21C 1.02 1.02 1.00 G1UA036S14 1.00 1.00 1.00 G1UA036S17,21 1.00 1.00 1.00 G1UA048S17 1.04 1.04 1.01 G1UA048S21,24 1.07 1.07 1.04 G2FD035S14 0.99 0.99 0.99 G2FD036S17 1.01 1.00 1.00 G2FD036S21 1.01 1.00 1.00 G2FD042S21 1.02 1.02 1.00 MDD42CSD 1.02 1.02 1.00 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA042S06, H1RA042S(25,46) INDOOR COIL MODEL NO. G1FA048S21,24 CONDENSER ENTERING AIR TEMPERATURE ID CFM ID DB (°F) 1200 85 80 1400 70 85 80 1600 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 47.2 44.1 41.2 47.5 44.6 41.9 47.9 45.1 42.6 S.C. 30.2 29.6 29.4 31.9 31.1 31.0 33.6 32.6 32.6 K.W 3.90 3.85 3.78 4.05 3.99 3.94 4.19 4.14 4.09 75 85 95 105 115 125 T.C. 45.5 42.1 38.5 45.9 42.8 39.3 46.3 43.4 40.2 S.C. 29.8 28.9 28.1 31.4 30.7 30.0 33.0 32.5 31.9 K.W 4.13 4.06 3.96 4.28 4.21 4.13 4.43 4.36 4.29 T.C. 43.9 40.2 35.7 44.3 41.0 36.8 44.8 41.8 37.8 S.C. 29.5 28.2 26.9 30.9 30.3 29.1 32.4 32.4 31.2 K.W 4.36 4.27 4.14 4.52 4.43 4.31 4.67 4.59 4.49 T.C. 40.5 36.3 32.0 41.2 37.1 32.8 42.0 38.0 33.7 S.C. 28.1 26.7 25.1 29.9 28.8 27.2 31.7 30.9 29.3 K.W 4.58 4.44 4.30 4.74 4.60 4.47 4.89 4.77 4.64 T.C. 37.1 32.3 28.3 38.2 33.3 28.9 39.2 34.2 29.6 S.C. 26.8 25.1 23.3 29.0 27.2 25.4 31.1 29.4 27.4 K.W 4.81 4.62 4.45 4.96 4.78 4.62 5.10 4.95 4.79 T.C. 33.7 28.4 24.5 35.1 29.4 25.0 36.4 30.4 25.4 S.C. 25.5 23.5 21.5 28.0 25.7 23.5 30.5 27.9 25.5 K.W 5.04 4.79 4.61 5.18 4.96 4.78 5.32 5.13 4.94 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHC1606 G2FD042S21 0.96 0.96 0.99 N1AHC1646 G2FD042S21 0.98 0.99 1.00 N1AHC1606 G2FD048S21 G2FD048S21 0.99 1.01 1.01 1.00 1.00 1.01 N1AHC1646 F2RP/F2FP042 0.96 0.95 0.99 F2RP/F2FP042 0.95 0.95 0.99 F2FP048 0.99 0.99 0.99 F2FP048 0.99 0.99 0.99 G1FA048S17 0.98 1.00 1.00 G1FA060S21,24 1.02 1.02 1.00 G1FA060S21,24 1.02 1.02 1.00 G1NA036S21C 0.98 0.93 0.99 G1HD048 0.99 0.99 1.01 G1NA048S21D 0.99 0.94 1.00 G1NA036S21C 0.98 0.93 0.99 G1UA048S21,24 1.00 1.00 1.00 G1NA048S21D 0.99 0.94 1.00 G1UA060S21,24 1.02 1.03 1.00 G1UA048S17 0.98 1.00 1.00 G2FD042S21 0.96 0.96 0.99 G1UA048S21,24 1.00 1.00 1.00 G2FD046S17 0.98 0.98 1.00 G1UA060S21,24 1.02 1.03 1.00 G2FD048S21,24 1.00 1.00 1.01 G2FD042S21 0.96 0.96 0.99 G2FD046S17 0.98 0.98 1.00 G2FD048S21,24 1.00 1.00 1.01 G2FD060S24 1.02 1.02 1.00 MDD48DSD 0.99 0.94 1.00 Unitary Products Group 13 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA048S06, H1RA048S(25,46) INDOOR COIL MODEL NO. G1FA048S21,24 ID CFM 1200 1400 1600 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB (°F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 53.4 48.9 45.1 40.2 54.3 49.8 45.9 41.3 54.9 50.3 46.4 41.8 75 S.C. 32.2 32.3 31.0 32.5 34.0 34.0 32.7 34.7 35.2 35.3 33.9 35.9 K.W 4.32 4.15 4.00 3.83 4.44 4.26 4.11 3.95 4.53 4.36 4.21 4.04 85 95 105 115 125 T.C. 52.0 47.5 43.7 39.2 52.7 48.3 44.5 40.0 53.2 48.7 45.2 40.5 S.C. 32.2 32.3 31.1 32.7 34.1 34.1 32.8 34.7 35.4 35.5 34.5 36.0 K.W 4.62 4.43 4.26 4.07 4.74 4.55 4.38 4.18 4.84 4.65 4.48 4.28 T.C. 49.0 44.9 41.3 36.9 49.6 45.5 42.0 37.6 50.0 45.8 42.4 38.3 S.C. 31.6 31.6 30.4 31.8 33.5 33.7 32.4 33.8 34.9 35.0 33.7 35.6 K.W 4.91 4.70 4.51 4.31 5.02 4.81 4.64 4.43 5.13 4.92 4.74 4.53 T.C. 45.6 41.6 38.4 34.3 46.0 42.2 39.0 35.0 46.2 42.5 39.3 36.2 S.C. 30.5 30.6 29.5 30.9 32.6 32.8 31.5 32.8 34.1 34.2 32.7 34.5 K.W 5.18 4.96 4.76 4.54 5.30 5.07 4.88 4.67 5.39 5.18 4.99 4.83 T.C. 41.8 38.3 35.3 31.7 42.3 38.8 35.8 33.0 42.5 39.0 36.2 33.5 S.C. 29.3 29.5 28.2 29.6 31.6 31.4 30.1 31.5 33.0 32.9 31.5 32.0 K.W 5.42 5.18 4.98 4.76 5.52 5.31 5.10 4.94 5.63 5.41 5.21 5.06 T.C. 38.0 35.0 32.3 29.1 38.6 35.4 32.7 31.0 38.8 35.5 33.2 30.8 S.C. 28.1 28.4 26.9 28.3 30.6 30.0 28.7 30.2 31.9 31.6 30.4 29.5 K.W 5.66 5.40 5.20 4.98 5.74 5.55 5.32 5.21 5.87 5.64 5.43 5.29 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHC1606 G2FD048S21 1.01 1.01 1.01 N1AHC1646 G2FD048S21 1.01 1.01 1.00 N1AHD2006 G2FD060S24 1.03 1.03 1.01 N1AHD2046 G2FD048S24 1.01 1.01 1.00 F2FP048 1.00 1.00 1.03 N1AHD2046 G2FD060S24 1.03 1.03 1.00 F2FP060 1.02 1.02 1.00 F2FP048 1.00 1.00 1.03 G1FA048S17 0.98 0.99 1.01 G1FA048S21,24 1.00 1.00 1.00 G1FA060S21,24 1.03 1.03 1.01 G1NA048S21D 1.02 1.02 1.02 G1HD048 1.00 1.00 0.99 G1UA048S21,24 1.00 1.00 1.00 G1HD060 1.02 1.02 1.00 G2FD048S21,24 1.01 1.01 1.01 14 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H3RA060S06 INDOOR COIL MODEL NO. G1FA060S21,24 CONDENSER ENTERING AIR TEMPERATURE ID CFM ID DB (°F) 2050 85 80 1800 70 85 80 1550 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 64.7 61.9 58.2 64.1 61.2 57.2 63.6 60.5 56.2 S.C. 46.3 44.9 42.9 43.3 42.1 40.3 40.3 39.3 37.7 K.W 5.18 5.13 5.03 5.08 5.02 4.92 4.97 4.91 4.81 75 85 95 105 115 125 T.C. 62.8 59.6 55.4 62.3 58.6 54.3 61.8 57.6 53.3 S.C. 45.9 44.3 41.9 42.8 41.2 39.2 39.7 38.2 36.5 K.W 4.94 4.86 4.77 5.58 5.50 5.40 5.48 5.40 5.28 T.C. 60.9 57.3 52.7 60.4 56.0 51.5 59.9 54.7 50.3 S.C. 45.7 43.5 40.8 42.4 40.2 38.0 39.2 37.0 35.2 K.W 6.19 6.10 6.00 6.09 5.99 5.87 5.98 5.88 5.74 T.C. 57.2 53.4 48.4 56.6 52.3 47.4 56.0 51.1 46.4 S.C. 44.6 42.1 39.3 41.3 39.0 36.6 38.0 35.9 33.8 K.W 6.82 6.70 6.56 6.71 6.59 6.44 6.60 6.47 6.31 T.C. 53.5 49.5 44.1 52.8 48.5 43.3 52.1 47.5 42.4 S.C. 43.6 40.5 37.7 40.2 37.6 35.1 36.8 34.7 32.4 K.W 7.47 7.32 7.14 7.35 7.19 7.01 7.22 7.06 6.88 T.C. 49.8 45.6 39.9 49.0 44.8 39.2 48.2 43.9 38.5 S.C. 42.5 39.0 36.1 39.0 36.3 33.6 35.6 33.6 31.0 K.W 8.12 7.94 7.72 7.99 7.79 7.58 7.84 7.65 7.45 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHD2006 G2FD060S24 1.00 1.00 1.00 1.00 1.02 1.02 F2FP060 G1HD060 0.99 1.00 1.01 G1NA048S21D 0.91 0.87 0.96 G1NA060S24T 0.98 0.99 0.99 G1UA060S21,24 1.00 1.00 1.00 G2FD060S24 1.00 1.00 1.00 G2FD061H24 1.02 1.02 1.02 Unitary Products Group 15 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA060S(25,46) INDOOR COIL MODEL NO. G2FD060S24A ID CFM 1450 1700 1950 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 61.2 58.5 56.3 61.8 59.1 56.9 62.3 59.6 57.5 75 S.C. 37.6 37.4 37.1 40.1 39.9 39.5 42.5 42.3 41.8 K.W 4.66 4.57 4.51 4.67 4.58 4.53 4.68 4.58 4.55 85 95 105 115 125 T.C. 60.6 58.0 55.0 61.2 58.6 55.8 61.9 59.3 56.7 S.C. 37.6 37.3 36.5 40.2 39.9 39.1 42.8 42.5 41.7 K.W 5.26 5.13 5.08 5.27 5.14 5.10 5.28 5.15 5.11 T.C. 60.0 57.4 53.7 60.7 58.5 54.8 61.4 59.0 55.8 S.C. 37.5 37.1 35.9 40.3 39.8 38.8 43.1 42.6 41.6 K.W 5.86 5.70 5.65 5.87 5.71 5.67 5.88 5.72 5.68 T.C. 58.1 54.6 50.0 58.9 55.7 51.3 59.7 56.8 52.7 S.C. 36.9 36.0 34.4 39.8 39.0 37.3 42.7 41.9 40.2 K.W 6.54 6.39 6.29 6.56 6.42 6.30 6.57 6.45 6.32 T.C. 56.2 51.8 46.3 57.1 53.2 47.9 57.9 54.5 49.5 S.C. 36.2 34.9 32.9 39.3 38.1 35.9 42.3 41.2 38.8 K.W 7.23 7.07 6.92 7.25 7.12 6.94 7.26 7.17 6.97 T.C. 54.3 49.0 42.6 55.2 50.6 44.5 56.2 52.3 46.4 S.C. 35.6 33.8 31.4 38.7 37.2 34.4 41.9 40.5 37.4 K.W 7.92 7.76 7.55 7.94 7.83 7.58 7.96 7.90 7.62 Multipliers for determining the performance with other indoor sections. Air Handler Coil T.C. S.C. KW N1AHD2046 G2FD060S24 1.00 1.00 1.00 1.00 1.00 1.05 G1FA060S21,24 1.00 1.00 1.00 G1NA060S24T 0.98 0.98 1.01 G1UA060S21,24 1.00 1.00 1.00 F2FP060 16 Unitary Products Group 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA076S(25,46) INDOOR COIL MODEL NO. K4EV090 CONDENSER ENTERING AIR TEMPERATURE ID CFM ID DB (°F) 2100 85 80 2600 70 85 80 3100 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 79.1 76.3 73.9 82.0 79.2 76.9 84.9 82.0 79.9 S.C. 48.8 48.6 48.1 55.4 55.3 54.7 62.0 61.9 61.3 K.W 5.98 5.90 5.84 6.28 6.18 6.15 6.58 6.48 6.46 75 85 95 105 115 125 T.C. 76.4 73.7 70.6 79.1 76.3 73.4 81.7 79.0 76.2 S.C. 47.9 47.6 46.8 54.7 54.4 53.5 61.5 61.2 60.3 K.W 6.53 6.42 6.37 6.86 6.74 6.70 7.18 7.07 7.04 T.C. 73.8 71.1 67.2 76.1 73.5 69.9 78.4 75.9 72.6 S.C. 47.1 46.7 45.4 54.0 53.6 52.4 60.9 60.4 59.4 K.W 7.08 6.94 6.90 7.43 7.30 7.26 7.79 7.65 7.61 T.C. 71.1 67.4 62.6 73.1 69.7 65.2 75.1 72.0 67.7 S.C. 46.4 45.4 43.7 53.1 52.2 50.5 59.8 58.9 57.2 K.W 7.84 7.70 7.61 8.21 8.08 7.99 8.57 8.46 8.36 T.C. 68.4 63.7 58.0 70.0 67.0 60.4 71.7 68.2 62.9 S.C. 45.4 44.1 42.0 52.0 51.9 48.5 58.6 57.5 55.0 K.W 8.59 8.46 8.32 8.97 8.80 8.71 9.36 9.28 9.10 T.C. 65.6 60.1 53.4 67.0 64.3 55.7 68.4 64.3 58.1 S.C. 44.5 42.7 40.2 51.0 51.6 46.5 57.5 56.0 52.8 K.W 9.35 9.21 9.02 9.74 9.51 9.43 10.14 10.09 9.84 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Coil T.C. S.C. KW G2FD090S35 1.00 0.99 1.01 Unitary Products Group 17 036-21121-002 Rev. A (0602) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H1RA090S(25,46) INDOOR COIL MODEL NO. K4EV090 ID CFM 2400 3000 3600 CONDENSER ENTERING AIR TEMPERATURE ID DB (°F) 85 80 70 85 80 70 85 80 70 ID WB (°F) 72 67 57 72 67 57 72 67 57 T.C. 104.2 97.2 90.1 108.1 100.5 92.8 112.1 103.8 95.5 75 S.C. 76.5 71.0 65.6 78.7 72.8 66.9 81.0 74.6 68.2 K.W 8.30 8.21 8.13 8.33 8.25 8.18 8.36 8.29 8.23 85 95 105 115 125 T.C. 99.1 92.4 85.8 102.0 94.7 87.5 104.8 97.0 89.1 S.C. 72.5 67.4 62.3 74.0 68.4 62.8 75.5 69.4 63.4 K.W 8.97 8.86 8.75 9.01 8.90 8.79 9.04 8.94 8.84 T.C. 94.0 87.7 81.5 95.8 89.0 82.1 97.5 90.1 82.7 S.C. 68.6 63.8 59.0 69.3 64.0 58.7 70.0 64.2 58.5 K.W 9.64 9.50 9.37 9.68 9.55 9.41 9.72 9.59 9.45 T.C. 88.2 82.2 76.1 89.8 83.9 77.9 91.4 85.6 79.7 S.C. 68.7 63.7 58.7 69.2 64.3 59.4 69.8 64.9 60.1 K.W 10.33 10.14 9.96 10.38 10.21 10.03 10.43 10.27 10.10 T.C. 82.5 76.6 70.8 83.9 78.8 73.8 85.3 81.0 76.7 S.C. 59.9 55.4 50.9 60.2 56.3 52.4 60.5 57.2 53.9 K.W 11.02 10.79 10.55 11.08 10.87 10.65 11.14 10.95 10.76 T.C. 76.7 71.1 65.5 78.0 73.8 69.6 79.2 76.5 73.7 S.C. 55.5 51.2 46.8 55.7 52.4 49.2 55.8 53.7 51.6 K.W 11.71 11.43 11.15 11.78 11.53 11.28 11.86 11.63 11.41 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Coil T.C. S.C. KW G2FD090S35 1.01 1.01 1.01 18 Unitary Products Group 036-21121-002 Rev. A (0602) MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1UA 1/2 CASED UPFLOW G1NA UNCASED UPFLOW G1HD HORIZONTAL DUCT G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW) G1FA FULL CASED UPFLOW G2FD090 is upflow only. * Available with factory installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW) LIGHT COMMERCIAL APPLICATIONS G2FD COIL Unitary Products Group F2RC / F2FC OR F2RC / F2FP FAN COIL UNITS (UPFLOW, HORIZONTAL) 19 NOTES Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2002. All rights reserved. Unitary Products Group 036-21121-002 Rev. A (0602) Supersedes: 036-21121-001 Rev. A (301) 5005 York Drive Norman OK 73069
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2002:06:25 20:37:06Z Modify Date : 2002:07:01 10:15:57-04:00 Page Count : 20 Creation Date : 2002:06:25 20:37:06Z Mod Date : 2002:07:01 10:15:57-04:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : sardom Metadata Date : 2002:07:01 10:15:57-04:00 Creator : sardom Title : Y-TG-HRA Page Mode : UseThumbsEXIF Metadata provided by EXIF.tools