York Pcg4 Packaged Unit Technical Guide 5005562 YTG B 0715
2015-09-09
: York Pcg4-Packaged-Unit-Technical-Guide york-pcg4-packaged-unit-technical-guide-812579 york pdf
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
5005562-YTG-B-0715 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONER/GAS HEAT 14 SEER – R-410A 2 THRU 5 NOMINAL TONS 50 - 125 MBH HEAT INPUT MODELS: PCG4*24 THRU 60 • Operating Efficiency - All PCG4 model gas units provide a minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. ® Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY* Extended 10-Years limited parts and compressor warranty Lifetime gas heat exchanger warranty with registration. * Extended warranty requires online registration within 90 days of purchase for replacement or closing for new home purchase. See limited warranty certificate in User’s Information Manual for details. • Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 6289 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5005562-YTG-B-0715 • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategically places embossments in the pan for optimum strength and rigidity. • Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. • Simple Control Circuit - A low voltage gas heat printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-nlock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. sure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. • Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. • Heat Exchangers - Gas heat exchangers use corrosionresistant, stainless-steel tubular construction to provide longlife, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. • Post Purge Induced Draft Combustion - Exhausts combustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. • Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nuisance lockouts. • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. • Low Maintenance - Long life, permanently lubricated outdoor and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. • Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. • Loss of Charge Sensor (S1-2LC00024) - Kit provides Loss of Charge sensor and wiring to provide safe shutdown of compressor. • Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PHE4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current generation Carrier replacements but are recommended for previous generation applications. Refer to the PCE4 price pages for more details. • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pres- 2 Johnson Controls Unitary Products 5005562-YTG-B-0715 NOMENCLATURE PCG 4 A 24 50 2 X 1 A 1 2 3 4 5 6 7 8 9 1. Model Family PCG - packaged A/C with gas heat, PHG - packaged heat pump with gas heat, PCE - packaged A/C with electric heat, PHE - packaged heat pump with electric heat 5. Gas Heating Input BTU/Hr x 1000 050 = 50,000 BTU/Hr. input, blank = electric heat 2. Nominal Cooling Efficiency 4 = 14 SEER, 6 = 16 SEER, etc. 7. NOx Approval X = low-NOx, blank = not low-Nox 3. Cabinet Size A = small 35 x 51, B = large 45 x 51 8. Generation Level 1 = first generation 4. Nominal Air Conditioning Cooling Capacity BTUx1000 24 = 24,000 BTU, etc. 9. Revision Level A = original release, B = second release 6. Voltage-Phase-Frequency 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 Examples: PCG4B421002X1A is a packaged A/C with gas heat, 14 SEER, 3-1/2 ton, large cabinet, single-stage heat, 100,000 BTU gas heat, 230 volt, single phase, low-NOx model (first generation, first release) COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL (Behind Panel) CONTROL BOARD TRANSFORMER BLOWER MOTOR HIGH VOLTAGE CONTACTOR TXV PRESSURE SWITCH INDOOR COIL DRAFT INDUCER BLOWER INDOOR BLOWER GAS VALVE COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS BURNER ASSEMBLY A0297-001 Unit Limitations Unit Limitations Model Unit Voltage Applied Voltage Outdoor DB Temp Min Max Max (°F) PCG4A24 208/230-1-60 187 252 125 PCG4A30 208/230-1-60 187 252 125 PCG4A36 208/230-1-60 187 252 125 PCG4A42 208/230-1-60 187 252 125 PCG4B48 208/230-1-60 187 252 125 PCG4B60 208/230-1-60 187 252 125 Johnson Controls Unitary Products 3 5005562-YTG-B-0715 ACCESSORIES • Propane Conversion Kit (S1-1NP0702, S1-1NP0701) - Kit includes burner orifices, gas valve conversion and installation instructions necessary to field convert unit from natural gas to propane. • Economizer for Downflow Applications (S1-2EE04708424, S1-2EE04708524) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Economizer for Horizontal Applications (S1-2EE04708624, S1-2EE04708724) - Modulating integrated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. • Single/Dual Enthalpy Sensor (S1-2EC04700624) - Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. • CO2 Sensor Kit (S1-2AQ04700824) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. • Outdoor Temp. Sensor Kit (S1-2EC04700724S1-2EC04700724v) - Additional outdoor air temp sensor kit used with economizers. • Filter/Frame Kit (Single Phase Only) (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. (filters not supplied) This kit is available for single phase horizontal or vertical duct applications. • Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. 4 • Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0110 kit and from rectangle to 14" round for the 1AK0111 kit. • Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. • Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. • Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. • Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) - Provides 0% through 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. • Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. • Low Ambient Kit (S1-2LA04700824) - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0º F. Standard unit operation 45º F. • Transformer Kit (S1-2EC06700124) - Kit provides necessary hardware to provide single phase models from factory furnished 40 VA transformer capability to 75 VA transformer capability. (Required on installations with economizer or motorized damper). • Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides necessary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. Johnson Controls Unitary Products 5005562-YTG-B-0715 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today’s market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21.47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powderpainted steel, certified at 1000 hours salt spray test per ASTMB117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. Indoor Blower Assembly - Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Johnson Controls Unitary Products Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Indoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. b. Indoor coil shall be of the direct expansion, draw through design. c. Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. d. Outdoor coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXV's) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. GAS HEATING SECTION Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(s) (manual reset). d. Flame proving controls. All gas heat models will meet the California requirement for emissions of less than 40 nanograms per Joule (California requirement on single phase models only). 5 5005562-YTG-B-0715 PHYSICAL DATA COMPONENT NOMINAL TONNAGE AHRI Cooling Performance Gross Capacity @ AHRI A point (MBH) AHRI net capacity (MBH) EER SEER Nominal CFM System power (KW) Refrigerant type Refrigerant charge (lb-oz) AHRI Gas Heat Performance Heating model Heat input (K Btu) Heat output (K Btu) AFUE % No. burners No. stages Temperature Rise Range (°F) Max. Static Pressure (in. w.c.) Max. Outlet Air Temp. (°F) Gas piping connection (in.) Dimensions (inches) Length Width Height Operating WT. (lbs.) Compressors Type Condenser Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Evaporator Coil Data Face area (Sq. Ft.) Rows Fins per inch Tube diameter Circuitry Type Refrigerant control Condenser Fan Data Fan diameter (Inch) Type Drive type No. speeds Motor HP each RPM Nominal total CFM Direct Drive Evaporator Fan Data Fan Size (Inch) Type Motor HP each RPM Frame size PCG4A24 2.0 PCG4A30 2.5 PCG4A36 3.0 23.7 22.8 11.0 14.0 800 2.1 R410A 5-4 30.1 29.0 11.0 14.0 1000 2.6 R410A 9-2 37.2 34.6 11.0 14.0 1200 3.2 R410A 8-3 MODELS PCG4A42 3.5 43.5 41.0 11.0 14.0 1400 3.8 R410A 9-4 PCG4B48 4.0 PCG4B60 5.0 47.7 45.5 11.0 14.0 1600 4.2 R410A 14-4 55.0 52.5 11.0 14.0 2000 4.8 R410A 14-2 50 75 50.0 75.0 40 60 81.0 81.0 2 3 1 1 40-70 0.5 180 1/2 50 75 50 75 100 75 100 65 100 125 65 100 125 50.0 75.0 50.0 75.0 100.0 75.0 100.0 65.0 100.0 125.0 65.0 100.0 125.0 40 60 40 60 80 60 80 52 80 100 52 80 100 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 81.0 2 3 2 3 4 3 4 2 3 4 2 3 4 1 1 1 1 1 1 1 1 1 1 1 1 1 40-70 35-65 40-70 40-70 40-70 40-70 0.5 0.5 0.5 0.5 0.5 180 180 180 180 180 1/2 1/2 1/2 1/2 1/2 51-1/4 35-3/4 47 359 366 51-1/4 35-3/4 47 379 386 51-1/4 35-3/4 47 415 422 426 51-1/4 35-3/4 49 442 446 51-1/4 45-3/4 53 495 503 508 51-1/4 45-3/4 55 522 530 535 Recip Recip Recip Scroll Scroll Scroll 15.1 2 16 3/8 Interlaced 17.0 3 16 3/8 Interlaced 17.0 3 16 3/8 Interlaced 17.0 3 16 3/8 Interlaced 23.8 3 16 3/8 Interlaced 26.0 3 16 3/8 Interlaced 3.4 2 16 3/8 Interlaced TXV 3.4 3 16 3/8 Interlaced TXV 3.4 3 16 3/8 Interlaced TXV 4.4 3 16 3/8 Interlaced TXV 4.4 3 16 3/8 Interlaced TXV 4.4 3 16 3/8 Interlaced TXV 24 Prop Direct 1 1/4 850 2400 24 Prop Direct 1 1/4 850 2400 24 Prop Direct 1 1/4 850 2400 24 Prop Direct 1 1/4 850 2400 26 Prop Direct 1 1/3 850 3200 26 Prop Direct 1 1/3 850 3200 11 x 8 Centrifugal 1/3 1/2 1200 Max 48 11 x 8 Centrifugal 1/3 1/2 1200 Max 48 11 x 10 Centrifugal 3/4 1200 Max 48 11 x 10 Centrifugal 3/4 1200 Max 48 11 x 10 Centrifugal 1 1200 Max 48 11 x 10 Centrifugal 1/2 3/4 1200 Max 48 Filters Quantity - Size 6 Field-supplied external filters must be sized so as not to exceed 300 FPM air velocity through disposable filters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. Johnson Controls Unitary Products 5005562-YTG-B-0715 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PCG4A24 80 57 30.0 30.0 1.48 25.9 25.6 1.57 26.9 26.9 1.77 22.0 21.7 1.86 22.1 22.1 2.07 19.3 19.3 2.21 16.6 16.6 2.36 13.9 13.9 2.50 80 62 33.4 28.6 1.47 29.1 23.6 1.58 28.4 25.8 1.78 23.8 20.6 1.87 22.8 22.7 2.07 19.9 19.8 2.21 17.0 17.0 2.35 14.1 14.1 2.49 1000 75 62 33.4 23.8 1.47 28.8 19.9 1.57 28.2 20.9 1.78 23.4 17.1 1.87 22.5 18.3 2.06 19.2 16.4 2.20 16.0 14.6 2.32 12.8 12.8 2.45 80 67 36.7 23.7 1.46 32.1 19.9 1.57 31.4 21.1 1.62 26.5 17.4 1.89 25.5 18.8 2.09 22.0 17.2 2.24 18.5 15.6 2.38 15.1 14.0 2.53 80 72 39.8 18.7 1.44 35.4 16.0 1.56 35.3 16.8 1.61 29.9 13.7 1.95 28.8 14.1 2.21 24.7 11.9 2.34 20.7 9.6 2.47 17.6 9.4 2.59 80 57 27.4 27.4 1.44 25.9 25.7 1.58 24.4 24.0 1.72 22.3 22.1 1.85 20.2 20.1 1.98 17.8 17.8 2.12 15.5 15.4 2.25 13.1 13.1 2.39 80 62 30.9 25.0 1.44 28.7 23.6 1.58 26.6 22.2 1.73 24.1 20.9 1.86 21.6 19.5 2.00 18.8 17.4 2.13 16.1 15.4 2.26 13.4 13.4 2.39 800 75 62 31.2 20.9 1.44 28.7 19.7 1.58 26.2 18.5 1.73 23.7 17.2 1.86 21.3 16.0 2.00 18.3 14.4 2.12 15.4 12.9 2.24 12.4 11.4 2.36 80 67 34.3 21.0 1.42 31.9 19.8 1.54 29.4 18.6 1.65 26.8 17.5 1.84 24.2 16.4 2.03 21.0 14.9 2.17 17.9 13.6 2.31 14.8 12.2 2.45 80 72 37.6 16.9 1.40 35.4 16.0 1.53 33.2 15.1 1.65 30.2 13.8 1.88 27.3 12.6 2.11 23.7 10.8 2.25 20.2 9.1 2.38 17.2 8.4 2.52 80 57 24.9 24.9 1.41 25.9 25.9 1.59 21.9 21.2 1.66 22.6 22.5 1.84 18.3 18.2 1.90 16.3 16.2 2.03 14.3 14.3 2.15 12.3 12.3 2.27 80 62 28.4 21.3 1.41 28.4 23.5 1.59 24.8 18.6 1.68 24.4 21.1 1.86 20.3 16.4 1.94 17.7 15.1 2.06 15.1 13.8 2.17 12.6 12.6 2.29 600 75 62 29.0 18.1 1.40 28.6 19.5 1.59 24.2 16.0 1.67 24.1 17.3 1.86 20.1 13.6 1.94 17.3 12.4 2.05 14.7 11.1 2.17 12.0 9.9 2.28 80 67 31.8 18.2 1.39 31.6 19.7 1.50 27.5 16.1 1.69 27.2 17.5 1.79 22.9 14.0 1.97 20.0 12.7 2.11 17.3 11.5 2.24 14.5 10.3 2.37 80 72 35.4 15.1 1.37 35.3 16.0 1.49 31.1 13.3 1.69 30.5 13.9 1.81 25.8 11.1 2.00 22.7 9.8 2.15 19.7 8.6 2.30 16.7 7.4 2.45 1200 75 62 43.2 32.6 1.71 38.8 30.5 1.89 34.3 28.4 2.08 29.8 26.1 2.24 25.3 23.7 2.41 20.6 19.5 2.56 16.0 15.5 2.71 11.4 11.4 2.86 80 67 44.9 31.1 1.68 41.6 29.8 1.88 38.3 28.5 2.08 34.2 26.7 2.27 30.1 24.8 2.45 25.9 22.4 2.61 21.8 20.1 2.77 17.7 17.7 2.92 80 72 48.3 24.5 1.66 45.6 23.4 1.86 42.9 22.3 2.06 38.6 20.6 2.27 34.3 18.9 2.47 28.7 16.9 2.67 23.3 14.9 2.86 17.8 13.0 3.06 80 57 37.8 36.9 1.67 34.4 34.0 1.83 31.1 31.1 1.99 27.8 27.8 2.15 24.4 24.4 2.32 20.3 20.3 2.49 16.3 16.3 2.66 12.3 12.3 2.83 80 62 41.0 34.5 1.66 37.6 32.5 1.83 34.1 30.5 2.00 30.3 28.1 2.16 26.4 25.7 2.31 22.8 22.3 2.49 19.3 19.0 2.65 15.7 15.7 2.82 1000 75 62 40.8 29.5 1.65 36.9 27.6 1.83 33.0 25.6 2.02 28.8 23.4 2.14 24.5 21.2 2.26 20.0 17.8 2.44 15.6 14.5 2.61 11.2 11.2 2.79 80 67 43.8 28.8 1.65 40.5 27.3 1.83 37.1 25.8 2.02 33.2 24.0 2.19 29.2 22.2 2.37 24.7 20.0 2.50 20.3 17.8 2.62 15.9 15.7 2.73 80 72 47.9 23.6 1.62 44.1 25.2 1.82 40.3 26.9 2.02 36.6 21.9 2.22 32.8 17.0 2.41 27.8 15.2 2.61 23.0 13.5 2.80 18.2 11.7 2.99 80 57 34.5 33.6 1.62 31.4 31.0 1.78 28.4 28.4 1.94 25.5 25.5 2.09 22.6 22.6 2.24 19.2 19.2 2.41 15.9 15.9 2.57 12.6 12.6 2.74 80 62 38.4 30.5 1.61 35.2 28.7 1.77 31.9 26.9 1.93 28.2 25.0 2.08 24.6 23.1 2.24 20.8 19.9 2.40 17.2 16.7 2.56 13.6 13.6 2.72 800 75 62 38.5 26.4 1.60 35.1 24.6 1.78 31.7 22.8 1.95 27.7 20.8 2.03 23.7 18.7 2.11 19.4 16.1 2.32 15.2 13.6 2.52 11.0 11.0 2.72 80 67 42.8 26.5 1.61 39.4 24.8 1.78 36.0 23.2 1.95 32.1 21.3 2.12 28.2 19.5 2.30 23.4 17.5 2.38 18.8 15.6 2.46 14.1 13.7 2.55 80 72 47.5 22.6 1.59 42.6 27.0 1.78 37.7 31.5 1.97 34.5 23.3 2.16 31.3 15.1 2.35 26.9 13.6 2.55 22.7 12.0 2.73 18.5 10.5 2.92 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PCG4A30 80 57 41.0 40.2 1.71 37.4 37.0 1.88 33.8 33.8 2.04 30.1 30.1 2.22 26.3 26.3 2.39 21.4 21.4 2.57 16.7 16.7 2.74 12.0 12.0 2.91 Johnson Controls Unitary Products 80 62 43.6 38.5 1.71 40.0 36.3 1.89 36.4 34.2 2.06 32.3 31.2 2.23 28.3 28.3 2.39 24.8 24.8 2.57 21.3 21.3 2.74 17.9 17.9 2.91 7 5005562-YTG-B-0715 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PCG4A36 80 57 45.3 45.3 2.15 42.0 42.0 2.39 38.7 38.7 2.63 35.3 35.3 2.87 31.9 31.9 3.11 26.5 26.5 3.43 21.4 21.4 3.74 16.2 16.2 4.05 80 62 48.1 43.2 2.16 43.7 40.3 2.41 39.3 37.4 2.66 35.4 34.4 2.90 31.5 31.5 3.14 26.8 26.8 3.39 22.3 22.3 3.65 17.7 17.7 3.90 1600 75 62 48.0 36.0 2.16 43.8 34.1 2.40 39.6 32.1 2.64 35.5 30.0 2.88 31.5 28.0 3.12 26.3 24.0 3.35 21.3 20.2 3.57 16.3 16.3 3.79 80 67 53.1 36.5 2.15 48.6 34.5 2.41 44.1 32.4 2.67 39.4 30.1 2.93 34.8 27.8 3.20 29.0 24.4 3.43 23.4 21.1 3.67 17.7 17.7 3.90 80 72 54.6 27.9 2.15 52.4 26.6 2.40 50.1 25.4 2.65 45.0 23.6 2.93 39.8 21.8 3.21 33.7 19.3 3.48 27.7 17.0 3.75 21.7 14.6 4.01 80 57 42.2 42.2 2.07 39.4 39.4 2.30 36.6 36.6 2.52 33.6 33.6 2.75 30.5 30.5 2.99 26.0 26.0 3.27 21.6 21.6 3.54 17.2 17.2 3.81 80 62 46.3 39.5 2.07 42.5 36.9 2.31 38.6 34.3 2.55 34.8 32.0 2.79 31.0 29.7 3.02 26.5 25.7 3.27 22.2 21.8 3.50 17.9 17.9 3.74 1400 75 62 46.2 33.3 2.07 42.4 31.3 2.31 38.5 29.3 2.54 34.8 27.5 2.77 31.0 25.7 3.00 26.2 22.6 3.23 21.4 19.7 3.44 16.7 16.7 3.66 80 67 51.3 33.4 2.06 47.1 31.5 2.32 42.9 29.5 2.57 38.7 27.5 2.83 34.6 25.5 3.08 29.1 22.8 3.32 23.8 20.2 3.54 18.5 17.6 3.77 80 72 53.5 26.1 2.05 51.0 24.9 2.31 48.4 23.6 2.56 43.8 21.9 2.83 39.2 20.2 3.10 33.5 18.0 3.37 28.0 15.9 3.63 22.5 13.8 3.88 80 57 39.2 39.2 1.99 36.8 36.8 2.20 34.5 34.5 2.41 31.9 31.9 2.64 29.2 29.2 2.87 25.5 25.5 3.11 21.8 21.8 3.34 18.2 18.2 3.57 80 62 44.6 35.8 1.99 41.2 33.5 2.22 37.9 31.1 2.45 34.2 29.5 2.68 30.5 27.9 2.91 26.3 24.5 3.14 22.2 21.3 3.36 18.0 18.0 3.58 1200 75 62 44.5 30.6 1.99 41.0 28.6 2.22 37.4 26.6 2.44 34.0 25.0 2.67 30.6 23.4 2.89 26.0 21.2 3.11 21.5 19.1 3.32 17.0 17.0 3.53 80 67 49.5 30.4 1.97 45.6 28.5 2.22 41.7 26.7 2.47 38.0 25.0 2.72 34.3 23.3 2.97 29.2 21.3 3.20 24.2 19.3 3.42 19.2 17.4 3.65 80 72 52.4 24.4 1.95 49.5 23.1 2.21 46.7 21.8 2.46 42.7 20.2 2.73 38.6 18.7 2.99 33.4 16.7 3.25 28.3 14.8 3.50 23.2 13.0 3.76 1600 75 62 50.2 38.5 2.51 47.0 36.4 2.74 43.7 34.3 2.97 40.1 32.8 3.28 36.5 31.3 3.59 31.8 28.4 4.01 27.3 25.6 4.42 22.8 22.8 4.83 80 67 55.5 39.6 2.53 52.1 37.7 2.77 48.7 35.9 3.01 44.9 33.9 3.31 41.1 32.0 3.60 36.1 29.5 4.03 31.1 27.2 4.45 26.2 24.8 4.87 80 72 61.9 32.6 2.56 58.0 30.8 2.80 54.1 29.0 3.04 50.0 27.3 3.36 46.0 25.5 3.67 40.6 23.3 4.09 35.3 21.2 4.50 30.1 19.1 4.91 80 57 46.5 45.5 2.42 44.4 43.7 2.55 42.2 41.9 2.67 39.3 39.2 2.98 36.5 36.5 3.29 32.5 32.5 3.72 28.7 28.7 4.14 24.9 24.9 4.57 80 62 48.6 42.1 2.44 45.6 40.5 2.68 42.6 38.8 2.93 40.0 36.1 3.24 37.4 33.3 3.54 33.0 30.3 3.97 28.8 27.4 4.38 24.5 24.5 4.79 1400 75 62 48.5 36.2 2.43 45.6 34.4 2.66 42.6 32.7 2.89 39.3 31.0 3.20 35.9 29.4 3.51 31.5 26.9 3.94 27.2 24.4 4.35 22.9 22.0 4.76 80 67 53.7 37.0 2.45 50.5 35.3 2.70 47.4 33.6 2.94 43.8 31.2 3.24 40.2 28.9 3.54 35.5 27.0 3.97 30.9 25.2 4.37 26.4 23.3 4.78 80 72 59.6 30.7 2.47 56.1 29.2 2.71 52.5 27.6 2.94 48.8 25.9 3.26 45.1 24.1 3.57 40.0 22.1 3.99 35.0 20.1 4.41 30.1 18.1 4.82 80 57 43.7 43.1 2.35 42.2 41.9 2.36 40.6 40.6 2.38 38.0 38.0 2.69 35.4 35.4 3.00 31.7 31.7 3.44 28.2 28.2 3.86 24.7 24.7 4.29 80 62 46.9 39.2 2.36 44.1 37.7 2.61 41.3 36.3 2.86 38.2 34.5 3.17 35.1 32.7 3.48 31.2 29.6 3.90 27.4 26.7 4.31 23.7 23.7 4.71 1200 75 62 46.8 33.9 2.36 44.1 32.5 2.59 41.4 31.0 2.82 38.4 29.3 3.13 35.4 27.6 3.44 31.2 25.4 3.86 27.1 23.3 4.28 23.0 21.2 4.69 80 67 51.8 34.4 2.38 48.9 32.8 2.62 46.0 31.3 2.87 42.7 28.5 3.18 39.3 25.8 3.48 34.9 24.5 3.90 30.7 23.1 4.30 26.5 21.8 4.70 80 72 57.3 28.7 2.38 54.1 27.5 2.61 51.0 26.2 2.84 47.6 24.5 3.15 44.1 22.8 3.47 39.4 20.9 3.90 34.7 19.0 4.31 30.1 17.2 4.73 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. PCG4A42 ID CFM CONDENSER ENTERING AIR IDDB 80 80 TEMPERATURE IDWB 57 62 T.C. 49.4 50.2 55 / 45 S.C. 47.8 45.0 K.W. 2.50 2.52 T.C. 46.6 47.0 65 / 55 S.C. 45.5 43.2 K.W. 2.73 2.76 T.C. 43.8 43.9 75 / 63 S.C. 43.3 41.4 K.W. 2.97 3.00 T.C. 40.7 41.8 85 / 69 S.C. 40.4 37.7 K.W. 3.28 3.30 T.C. 37.6 39.7 95 / 75 S.C. 37.6 33.9 K.W. 3.59 3.60 T.C. 33.3 34.8 105 / 83 S.C. 33.3 31.0 K.W. 4.01 4.03 T.C. 29.2 30.1 115 / 89 S.C. 29.2 28.2 K.W. 4.43 4.45 T.C. 25.1 25.4 125 / 95 S.C. 25.1 25.4 K.W. 4.84 4.86 8 Johnson Controls Unitary Products 5005562-YTG-B-0715 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PCG4B48 80 57 58.1 57.1 2.21 54.4 54.0 2.46 50.8 50.8 2.71 46.5 46.5 3.05 42.2 42.2 3.39 37.2 37.2 3.85 32.4 32.4 4.31 27.6 27.6 4.76 80 62 61.5 53.6 2.21 56.8 51.5 2.47 52.2 49.5 2.73 47.2 45.8 3.06 42.2 42.2 3.38 37.0 37.0 3.85 31.9 31.9 4.31 26.9 26.9 4.76 1600 75 62 60.2 44.4 2.20 55.7 42.4 2.46 51.2 40.4 2.72 46.2 37.7 3.05 41.2 35.0 3.38 35.3 31.2 3.85 29.6 27.5 4.30 23.9 23.9 4.76 80 67 66.8 44.1 2.23 62.2 42.4 2.49 57.6 40.6 2.75 52.4 38.1 3.08 47.2 35.6 3.41 40.9 33.3 3.88 34.9 31.0 4.33 28.8 28.8 4.79 80 72 70.0 33.9 2.25 66.3 32.4 2.50 62.5 30.9 2.76 57.6 28.7 3.09 52.7 26.5 3.42 46.8 24.7 3.89 41.1 23.0 4.35 35.5 21.2 4.80 80 57 55.6 54.5 2.20 52.1 51.6 2.44 48.7 48.7 2.69 44.6 44.6 3.04 40.6 40.6 3.38 36.1 36.1 3.85 31.7 31.7 4.30 27.3 27.3 4.76 80 62 59.5 49.9 2.21 55.1 48.0 2.46 50.7 46.0 2.72 46.0 42.9 3.05 41.3 39.8 3.38 36.2 35.2 3.85 31.2 30.7 4.31 26.2 26.2 4.77 1400 75 62 58.7 42.1 2.20 54.4 40.1 2.45 50.1 38.2 2.71 45.1 35.5 3.04 40.2 32.9 3.38 35.0 30.1 3.85 30.1 27.3 4.30 25.1 24.6 4.76 80 67 65.1 41.9 2.23 60.9 40.2 2.49 56.6 38.5 2.75 51.5 35.9 3.08 46.4 33.4 3.41 40.6 31.3 3.88 35.1 29.3 4.33 29.6 27.4 4.79 80 72 70.0 33.5 2.24 65.7 31.5 2.49 61.4 29.5 2.75 56.8 27.5 3.09 52.2 25.4 3.42 46.5 23.7 3.89 41.0 22.0 4.34 35.6 20.3 4.80 80 57 53.1 51.9 2.18 49.8 49.2 2.43 46.5 46.5 2.68 42.8 42.8 3.02 39.0 39.0 3.36 34.9 34.9 3.84 30.9 30.9 4.30 27.0 27.0 4.76 80 62 57.5 46.3 2.20 53.4 44.5 2.46 49.3 42.6 2.71 44.9 40.0 3.05 40.5 37.4 3.38 35.4 33.4 3.86 30.5 29.5 4.31 25.5 25.5 4.77 1200 75 62 57.2 39.7 2.19 53.1 37.9 2.45 49.0 36.0 2.70 44.1 33.3 3.03 39.2 30.7 3.37 34.8 28.9 3.84 30.6 27.1 4.30 26.4 25.4 4.76 80 67 63.4 39.6 2.22 59.5 38.0 2.48 55.6 36.3 2.74 50.6 33.8 3.07 45.5 31.2 3.40 40.3 29.4 3.87 35.3 27.6 4.33 30.3 25.9 4.79 80 72 69.9 33.0 2.23 65.1 30.6 2.49 60.3 28.2 2.74 56.0 26.3 3.08 51.7 24.3 3.42 46.2 22.7 3.88 41.0 21.0 4.34 35.7 19.4 4.79 1600 75 62 65.2 49.1 3.43 28.9 23.1 3.74 57.7 46.1 4.05 52.8 43.8 4.45 47.9 41.5 4.84 39.9 35.7 5.41 32.1 30.0 5.97 24.4 24.4 6.53 80 67 68.7 46.2 3.43 32.9 23.1 3.76 65.7 46.2 4.09 60.0 44.0 4.48 54.3 41.8 4.86 46.0 37.8 5.42 38.0 33.9 5.96 30.0 30.0 6.49 80 72 72.9 34.9 3.41 36.7 17.6 3.76 73.2 35.2 4.11 60.4 41.4 4.47 47.5 47.5 4.83 44.7 39.3 5.41 42.0 31.3 5.98 39.3 23.4 6.55 80 57 60.4 60.4 3.28 56.7 56.7 3.57 53.0 53.0 3.87 26.5 26.5 4.26 46.0 46.0 4.66 41.5 41.5 5.23 37.1 37.1 5.79 32.7 32.7 6.35 80 62 64.1 54.7 3.29 60.5 53.5 3.59 56.9 52.3 3.88 52.5 49.3 4.28 48.1 46.3 4.68 42.6 41.4 5.25 37.2 36.6 5.80 31.9 31.9 6.35 1400 75 62 64.4 46.3 3.33 28.4 21.5 3.61 56.7 43.0 3.89 52.2 40.9 4.29 47.8 38.8 4.69 40.0 34.1 5.26 32.5 29.5 5.82 25.0 25.0 6.38 80 67 68.0 44.2 3.34 32.2 21.6 3.63 64.4 43.1 3.92 59.2 41.1 4.31 54.0 39.0 4.71 46.1 35.6 5.26 38.5 32.2 5.81 31.0 28.8 6.35 80 72 71.8 33.9 3.32 36.0 16.8 3.64 72.0 33.6 3.96 63.2 35.7 4.33 54.3 37.9 4.70 49.5 32.5 5.27 44.8 27.4 5.83 40.1 22.2 6.38 80 57 57.6 57.6 3.12 54.3 54.3 3.41 51.0 51.0 3.70 25.5 25.5 4.11 44.4 44.4 4.51 40.0 40.0 5.10 35.6 35.6 5.66 31.2 31.2 6.23 80 62 62.7 51.4 3.14 59.1 49.7 3.43 55.5 48.1 3.72 51.5 46.0 4.12 47.5 43.9 4.52 41.1 38.7 5.09 34.9 33.7 5.64 28.7 28.7 6.19 1200 75 62 63.6 43.4 3.23 27.9 20.0 3.48 55.7 40.0 3.73 51.6 38.0 4.13 47.6 36.1 4.53 40.1 32.5 5.11 32.9 29.1 5.67 25.6 25.6 6.24 80 67 67.2 42.2 3.24 31.6 20.0 3.50 63.1 40.0 3.76 58.4 38.1 4.15 53.6 36.3 4.55 46.2 33.3 5.11 39.0 30.5 5.66 31.9 27.6 6.21 80 72 70.6 32.8 3.23 35.4 16.0 3.52 70.7 32.0 3.80 65.9 30.1 4.19 61.1 28.2 4.57 54.3 25.7 5.13 47.6 23.4 5.67 41.0 21.0 6.21 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. ID CFM CONDENSER ENTERING AIR IDDB TEMPERATURE IDWB T.C. 55 / 45 S.C. K.W. T.C. 65 / 55 S.C. K.W. T.C. 75 / 63 S.C. K.W. T.C. 85 / 69 S.C. K.W. T.C. 95 / 75 S.C. K.W. T.C. 105 / 83 S.C. K.W. T.C. 115 / 89 S.C. K.W. T.C. 125 / 95 S.C. K.W. PCG4B60 80 57 63.1 63.1 3.44 59.1 59.1 3.74 55.1 55.1 4.03 27.6 27.6 4.42 47.5 47.5 4.80 43.0 43.0 5.37 38.6 38.6 5.92 34.2 34.2 6.47 Johnson Controls Unitary Products 80 62 65.4 58.0 3.44 61.9 57.3 3.75 58.3 56.5 4.05 53.5 52.6 4.44 48.7 48.7 4.84 44.0 44.0 5.40 39.6 39.6 5.96 35.1 35.1 6.51 9 5005562-YTG-B-0715 DIMENSIONS COIL GUARD HIGH VOLTAGE CONNECTION 7/8” C HIGH VOLTAGE CONNECTION 1-3/32” COMBUSTION AIR INTAKE HEAT EXCHANGER ACCESS PANEL COMPRESSOR ACCESS PANEL EXHAUST HOOD CONDENSATE DRAIN BLOWER ACCESS PANEL A B LOW VOLTAGE CONNECTION GAS SUPPLY CONTROL ACCESS PANEL A0296-001 Unit Dimensions Dimensions Model A B C PCG4A24 51-1/4 35-3/4 47 PCG4A30 51-1/4 35-3/4 47 PCG4A36 51-1/4 35-3/4 47 PCG4A42 51-1/4 35-3/4 49 PCG4B48 51-1/4 45-3/4 53 PCG4B60 51-1/4 45-3/4 55 Unit Clearances1 2 Direction Distance (in.) Direction Top3 36 Power Entry (Right Side) 36 Side Opposite Ducts 36 Left Side 24 Duct Panel 0 Bottom4 1 1. 2. 3. 4. 10 Distance (in.) A 1" clearance must be provided between any combustible material and the supply air duct work. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. Units may be installed on combustible floors made from class A, B or C roof covering materials. Johnson Controls Unitary Products 5005562-YTG-B-0715 Indoor Blower Specifications Motor Model HP RPM EFF. SF Frame 24050 1/3 Variable 0.8 1.0 48 24075 1/2 Variable 0.8 1.0 48 30050 1/3 Variable 0.8 1.0 48 30075 1/2 Variable 0.8 1.0 48 36050 1/2 Variable 0.8 1.0 48 36075 1/2 Variable 0.8 1.0 48 36100 3/4 Variable 0.8 1.0 48 42075 3/4 Variable 0.8 1.0 48 42100 3/4 Variable 0.8 1.0 48 48065 3/4 Variable 0.8 1.0 48 48100 3/4 Variable 0.8 1.0 48 48125 3/4 Variable 0.8 1.0 48 60065 1 Variable 0.8 1.0 48 60100 1 Variable 0.8 1.0 48 60125 1 Variable 0.8 1.0 48 Sound Performance Model (Tons) Sound Rating1 dB (A) 125 250 500 1000 2000 4000 8000 PCG4A24 75 62.4 61.5 64.2 67.0 61.0 57.3 49.6 PCG4A30 75 60.5 61.6 64.8 66.9 60.9 56.0 49.7 PCG4A36 74 58.5 61.8 65.4 66.5 60.7 54.8 49.8 PCG4A42 74 63.5 63.9 62.3 65.0 64.0 54.1 46.6 PCG4B48 74 63.5 63.9 62.3 65.0 64.0 54.1 46.6 PCG4B60 76 72.3 65.0 63.9 64.0 60.0 55.5 49.0 Octave Band Centerline Frequency (Hz) 1. Rated in accordance with AHRI Standard 270. Electrical Data Model Compressor Voltage RLA LRA MCC OD Fan Motor Supply Blower Motor FLA FLA MCA1 (Amps) Max Fuse2/ Breaker3 Size (Amps) 24050 208/230-1-60 8.7 45.0 14.4 1.3 2.6 14.8 20 24075 208/230-1-60 8.7 45.0 14.4 1.3 3.8 16.0 20 30050 208/230-1-60 9.8 57.0 15.1 1.3 2.6 16.2 25 30075 208/230-1-60 9.8 57.0 15.1 1.3 3.8 17.4 25 30 36050, 36075 208/230-1-60 13.0 78.0 23.0 1.3 3.8 21.4 36100 208/230-1-60 13.0 78.0 23.0 1.3 5.4 23.0 35 42075, 42100 208/230-1-60 17.9 112.0 28.0 1.3 5.4 29.1 45 48065, 48100, 48125 208/230-1-60 21.8 117.0 34.0 1.7 5.4 34.4 50 60065, 60100, 60125 208/230-1-60 24.4 144.2 38.0 1.7 7.0 39.2 60 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products 11 5005562-YTG-B-0715 WEIGHTS & DIMENSIONS "D" CENTER OF GRAVITY COMPRESSOR "C" "A" FRONT OF UNIT Y "B" X A0295-001-TG Weights and Dimensions Model 12 Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) 24050 Shipping 372 Operating 367 X 28 Y 15 A 120 B 95 C 81 D 71 24075 382 377 28 15 124 96 81 76 30050 417 412 28 15 139 99 90 84 30075 421 416 28 15 146 93 82 95 36050 425 420 28 15 141 107 94 78 36075 432 427 28 15 135 115 103 74 36100 436 431 28 15 139 113 99 80 42075 446 441 28 15 145 112 99 85 42100 448 443 28 15 148 110 96 89 48065 520 515 28 15 189 116 93 117 48100 528 523 28 15 169 139 115 100 48125 533 528 28 15 164 145 124 95 60065 537 532 29 15 174 142 124 92 60100 541 536 28 15 177 140 117 102 60125 548 543 27 15 151 167 141 84 Johnson Controls Unitary Products 5005562-YTG-B-0715 AIRFLOW PERFORMANCE Airflow - Side Duct Application External Static Pressure (Inches WC) Model 24050 24075 30050 30075 36050 36075 36100 42075 42100 48065 Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 732 667 624 567 517 470 415 369 Low/Medium (2) 818 771 723 674 628 579 530 482 Medium (3) 823 774 721 676 631 583 533 505 Medium/High (4) 994 948 906 865 823 778 739 700 High (5) 1148 1108 1071 1035 996 960 925 901 Low (1) 887 847 802 750 705 664 613 563 Low/Medium (2) 978 941 898 850 803 759 713 667 Medium (3) 1171 1114 1074 1039 993 949 906 864 Medium/High (4) 1349 1297 1265 1224 1185 1146 1107 1063 High (5) 1487 1462 1392 1331 1318 1281 1241 1201 Low (1) 700 657 599 554 512 461 411 365 Low/Medium (2) 906 868 825 779 735 692 650 608 Medium (3) 992 951 911 868 826 787 747 712 Medium/High (4) 1075 1032 1000 958 918 874 837 800 High (5) 1136 1089 1053 1018 978 941 903 869 Low (1) 1076 1020 984 943 903 859 819 779 Low/Medium (2) 1102 1048 1010 974 934 890 850 810 Medium (3) 1191 1140 1112 1076 1038 1000 958 919 Medium/High (4) 1201 1225 1187 1151 1118 1080 1041 1002 High (5) 1370 1329 1283 1271 1209 1176 1143 1109 Low (1) 1003 952 904 851 790 730 674 633 Low/Medium (2) 1180 1133 1085 1042 995 942 889 834 Medium (3) 1259 1209 1166 1126 1084 1032 980 928 Medium/High (4) 1314 1271 1229 1186 1144 1097 1049 998 High (5) 1506 1471 1403 1389 1345 1305 1262 1216 Low (1) 1225 1174 1131 1090 1046 993 941 888 Low/Medium (2) 1259 1209 1166 1126 1084 1032 980 928 Medium (3) 1314 1271 1229 1186 1144 1097 1049 998 Medium/High (4) 1348 1306 1259 1222 1179 1133 1086 1036 High (5) 1506 1471 1403 1389 1345 1305 1262 1216 Low (1) 1342 1302 1260 1217 1178 1134 1082 1034 Low/Medium (2) 1425 1368 1332 1293 1251 1208 1163 1113 Medium (3) 1554 1503 1465 1423 1386 1346 1302 1257 Medium/High (4) 1658 1599 1588 1530 1495 1454 1414 1373 High (5) 1966 1914 1862 1810 1757 1705 1653 1600 Low (1) 1315 1266 1229 1194 1156 1117 1080 1036 Low/Medium (2) 1436 1382 1342 1304 1262 1220 1179 1131 Medium (3) 1458 1406 1365 1327 1286 1244 1203 1155 Medium/High (4) 1573 1523 1484 1445 1408 1367 1327 1279 High (5) 1966 1914 1862 1810 1757 1705 1653 1600 Low (1) 1436 1382 1342 1304 1262 1220 1179 1131 Low/Medium (2) 1544 1492 1455 1416 1376 1336 1294 1248 Medium (3) 1573 1523 1484 1445 1408 1367 1327 1279 Medium/High (4) 1681 1640 1599 1557 1517 1478 1436 1393 1591 High (5) 1935 1887 1834 1788 1743 1701 1651 Low (1) 1046 1009 980 946 915 878 844 779 Low/Medium (2) 1295 1250 1213 1172 1133 1087 1045 964 Medium (3) 1620 1564 1517 1466 1418 1360 1308 1206 Medium/High (4) 1798 1722 1669 1620 1572 1527 1480 1413 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 Continued on next page. Johnson Controls Unitary Products 13 5005562-YTG-B-0715 Airflow - Side Duct Application (Continued) External Static Pressure (Inches WC) Model 48100 48125 60065 60100 60125 1. 2. 3. 4. 5. 14 Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 1620 1564 1517 1466 1418 1360 1308 1206 Low/Medium (2) 1694 1630 1580 1530 1482 1430 1380 1292 Medium (3) 1798 1722 1669 1620 1572 1527 1480 1413 Medium/High (4) 1835 1758 1703 1653 1604 1558 1511 1442 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 Low (1) 1620 1564 1517 1466 1418 1360 1308 1206 Low/Medium (2) 1798 1722 1669 1620 1572 1527 1480 1413 Medium (3) 1922 1863 1804 1754 1724 1658 1612 1559 Medium/High (4) 2001 1952 1890 1839 1820 1742 1696 1651 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 Low (1) 1073 1043 1009 988 963 941 917 892 Low/Medium (2) 1329 1292 1250 1223 1192 1165 1136 1105 Medium (3) 2054 1998 1934 1890 1843 1801 1757 1710 Medium/High (4) 2195 2144 2098 2049 2003 1955 1883 1868 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 Low (1) 1730 1682 1628 1592 1552 1517 1479 1439 Low/Medium (2) 1858 1807 1749 1710 1667 1629 1589 1546 Medium (3) 2054 1998 1934 1890 1843 1801 1757 1710 Medium/High (4) 2195 2144 2098 2049 2003 1955 1883 1868 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 Low (1) 2063 2008 1943 1899 1851 1809 1763 1717 Low/Medium (2) 2130 2084 2032 1983 1927 1951 1860 1815 Medium (3) 2195 2144 2098 2049 2003 1955 1883 1868 Medium/High (4) 2275 2252 2169 2154 2112 2065 1989 1976 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 Airflow tested with dry coil conditions, without air flitters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5005562-YTG-B-0715 Airflow - Bottom Duct Application External Static Pressure (Inches WC) Model 24050 24075 30050 30075 36050 36075 36100 42075 42100 48065 Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 754 710 665 611 560 491 445 391 Low/Medium (2) 867 815 773 720 677 622 559 505 Medium (3) 951 908 868 828 781 735 686 631 Medium/High (4) 1024 982 942 902 861 817 775 721 High (5) 1204 1159 1121 1085 1051 1013 975 938 Low (1) 899 869 827 782 734 685 630 575 Low/Medium (2) 1033 960 924 879 834 787 735 685 Medium (3) 1186 1133 1095 1056 1016 975 935 891 Medium/High (4) 1357 1322 1284 1248 1211 1174 1127 1087 High (5) 1480 1439 1404 1367 1369 1299 1264 1226 Low (1) 726 676 622 575 520 467 410 376 Low/Medium (2) 928 886 841 795 745 706 658 607 Medium (3) 1021 983 942 900 855 811 770 729 Medium/High (4) 1109 1071 1029 995 949 908 864 826 High (5) 1170 1134 1096 1061 1020 978 938 899 Low (1) 1076 1042 1009 969 930 890 849 808 Low/Medium (2) 1104 1063 1025 987 947 908 869 830 Medium (3) 1205 1170 1136 1098 1060 1025 985 943 Medium/High (4) 1285 1251 1213 1179 1141 1104 1065 1027 High (5) 1406 1375 1341 1306 1271 1236 1198 1163 Low (1) 1008 962 916 861 807 757 700 650 Low/Medium (2) 1190 1148 1106 1055 1008 955 914 863 Medium (3) 1262 1223 1181 1137 1091 1044 994 952 Medium/High (4) 1324 1282 1245 1202 1161 1112 1067 1018 High (5) 1517 1475 1447 1400 1357 1318 1275 1232 Low (1) 1231 1186 1146 1103 1069 1030 977 912 Low/Medium (2) 1270 1225 1189 1140 1098 1046 1008 960 Medium (3) 1317 1286 1245 1198 1151 1110 1064 1024 Medium/High (4) 1358 1317 1275 1238 1197 1148 1105 1057 High (5) 1517 1475 1447 1400 1357 1318 1275 1232 Low (1) 1340 1299 1264 1224 1182 1182 1097 1049 Low/Medium (2) 1409 1368 1334 1291 1253 1201 1173 1128 Medium (3) 1527 1492 1470 1419 1385 1343 1299 1250 Medium/High (4) 1663 1585 1594 1601 1521 1480 1440 1400 High (5) 1930 1892 1853 1805 1760 1696 1625 1553 Low (1) 1332 1295 1263 1222 1185 1148 1110 1063 Low/Medium (2) 1457 1419 1376 1340 1299 1253 1215 1160 Medium (3) 1451 1412 1371 1339 1296 1257 1211 1165 Medium/High (4) 1568 1524 1491 1464 1425 1383 1345 1296 High (5) 1978 1937 1891 1837 1785 1725 1656 1604 Low (1) 1455 1414 1379 1335 1294 1254 1212 1160 Low/Medium (2) 1566 1532 1492 1455 1416 1372 1333 1280 Medium (3) 1565 1530 1491 1458 1419 1381 1336 1290 Medium/High (4) 1675 1641 1606 1578 1535 1495 1455 1412 High (5) 1946 1909 1863 1815 1771 1721 1654 1595 Low (1) 1032 999 970 938 910 879 843 808 Low/Medium (2) 1272 1236 1204 1165 1129 1081 1037 968 Medium (3) 1611 1574 1518 1494 1439 1405 1357 1266 Medium/High (4) 1892 1777 1771 1701 1639 1617 1565 1489 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 Continued on next page. Johnson Controls Unitary Products 15 5005562-YTG-B-0715 Airflow - Bottom Duct Application (Continued) External Static Pressure (Inches WC) Model 48100 48125 60065 60100 60125 1. 2. 3. 4. 5. 16 Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 1598 1548 1502 1454 1410 1362 1307 1251 Low/Medium (2) 1663 1612 1568 1522 1476 1422 1370 1297 Medium (3) 1789 1733 1670 1650 1596 1578 1535 1483 Medium/High (4) 1931 1814 1808 1736 1673 1650 1597 1519 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 Low (1) 1598 1548 1502 1454 1410 1362 1307 1251 Low/Medium (2) 1766 1703 1656 1611 1566 1518 1469 1419 Medium (3) 1912 1875 1805 1787 1750 1713 1672 1636 Medium/High (4) 2105 2014 2006 1931 1898 1845 1793 1739 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 Low (1) 1026 999 989 950 907 907 886 862 Low/Medium (2) 1263 1230 1192 1165 1167 1101 1099 1071 Medium (3) 1987 1933 1861 1817 1820 1715 1725 1651 Medium/High (4) 2114 2050 2047 1974 1899 1889 1920 1866 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 Low (1) 1655 1612 1596 1531 1461 1462 1429 1391 Low/Medium (2) 1766 1720 1667 1629 1632 1539 1537 1498 Medium (3) 1987 1933 1861 1817 1820 1715 1725 1651 Medium/High (4) 2114 2050 2047 1974 1899 1889 1920 1866 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 Low (1) 1973 1924 1905 1826 1743 1744 1703 1660 Low/Medium (2) 2024 1983 1937 1889 1886 1843 1799 1759 Medium (3) 2123 2075 2019 1970 1978 1862 1849 1804 Medium/High (4) 2191 2154 2117 2075 2002 1995 2028 1974 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 Airflow tested with dry coil conditions, without air flitters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5005562-YTG-B-0715 BOTTOM DUCT DIMENSIONS (Inches) Additional Static Resistance Size (Tons) 024 (2.0) 030 (2.5) 036 (3.0) 042 (3.5) 048 (4.0) 060 (5.0) CFM 500 600 700 800 900 1000 1100 1200 700 800 900 1000 1100 1200 1300 700 800 900 1000 1100 1200 1300 1400 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 Wet Indoor Coil Economizer1 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.09 0.00 0.00 0.00 0.01 0.01 0.01 0.01 0.02 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.00 0.01 0.01 0.01 0.01 0.02 0.03 0.04 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.02 0.02 0.02 0.03 0.04 0.04 0.04 0.04 0.05 0.05 Filter/Frame Kit 0.01 0.02 0.04 0.06 0.08 0.10 0.13 0.16 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.04 0.06 0.08 0.10 0.13 0.16 0.17 0.18 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 0.04 0.04 0.05 0.05 0.06 0.07 0.08 0.09 0.10 0.11 D 16 C A RETURN AIR DUCT E B A SUPPLY AIR DUCT F Model 24, 30, 36, 42 48, 60 A 10 14 B 21.5 13.5 A0298-001 C 5 5 D 4.5 3.5 E 47.5 47.5 F 32 42 REAR DUCT DIMENSIONS (Inches) 15.6 SUPPLY AIR DUCT RETURN AIR DUCT 6 A0299-001 Model 24, 30, 36, 42 48, 60 A B A 9.6 13.6 A 4.3 B 22 14 1. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. 2. Filter pressure drop based on standard filter media tested at velocities not to exceed 300 ft/min. Johnson Controls Unitary Products 17 5005562-YTG-B-0715 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324-001 UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN AIR DUCT SUPPLY AIR DUCT FIELD-SUPPLIED DISCONNECT SWITCH CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE TO GAS SUPPLY LINE 18 CONTROL WIRING TO INDOOR THERMOSTAT A0325-001 Johnson Controls Unitary Products 5005562-YTG-B-0715 UNIT TYPICAL ROOF CURB INSTALLATION ROOF CONDENSATE DRAIN MANUAL GAS SHUTOFF VAVLE ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH TO GAS SUPPLY LINE TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT SUPPLY AIR DUCT A0326-001 EXTERNAL STATIC PRESSURE SETUP To measure external static pressure: • • • • • • Measure the supply air static pressure Record this positive number Measure the return air static pressure Record this negative number Treat the negative number as a positive and add the two numbers together This is total system static Johnson Controls Unitary Products 19 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5005562-YTG-B-0715 Supersedes: 5005562-YTG-B-0215
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : csardom Create Date : 2015:07:23 10:05:53-05:00 Modify Date : 2015:07:23 11:05:35-05:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Producer : Acrobat Distiller 15.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:07:23 11:05:35-05:00 Format : application/pdf Title : 5005562-YTG-B-0715.fm Creator : csardom Document ID : uuid:bc7e2265-c30d-491b-af33-fb091a68bb8e Instance ID : uuid:78cb88a0-ff0b-49bf-87f3-ee320aab8a2b Page Layout : OneColumn Page Mode : UseThumbs Page Count : 20EXIF Metadata provided by EXIF.tools