York Tg9S Technical Guide 400991 YTG H 0615
2015-09-09
: York Tg9S-Technical-Guide york-tg9s-technical-guide-811954 york pdf
Open the PDF directly: View PDF .
Page Count: 6
Download | ![]() |
Open PDF In Browser | View PDF |
400991-YTG-H-0615 DESCRIPTION These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S NATURAL GAS 40 - 130 MBH INPUT These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV, National Fuel Gas Code and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Polyflue (a polypropylene venting systems). FEATURES • • • • • • • • • • • • • • • • • • Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at • • • • • • www.ahridirectory.org WARRANTY SUMMARY A 20-year limited warranty on heat exchangers in residential applications. A 10-year warranty on the heat exchanger in commercial applications. Standard 5-year limited Parts warranty. Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. • • • • • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. Compact, easy to install, ideal height 33" tall cabinet. Blower-off delay for cooling SEER improvement. Easy access to controls to connect power/control wiring. Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation. Low unit amp requirement for easy replacement application. Single wire twinning or staging feature available. All models are convertible to use propane (LP) gas. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. 100% shut off main gas valve for extra safety. 4 speed, direct drive PSC motor. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Secondary heat exchanger made of corrosion resistant stainless steel materials. Timed on, adjustable off blower capability for maximum comfort. Blower door safety switch. Solid removable bottom panel allows easy conversion. Airflow leakage less than 1% of nominal airflow at ductblaster conditions. No knockouts to deal with, making installation easier. Movable duct connector flanges for application flexibility. Quiet inducer operation. Inducer rotates for easy conversion of venting options. Fully supported blower assembly for easy access and removal of blower. External air filters used for maximum flexibility in meeting customers IAQ needs. Protection included from air intake, exhaust vent, or condensate blockage. No special vent termination required. 1/4 turn knobs provided for easy door removal. Internal condensate trap design (patent pending) provides condensate management options and is self-priming to prevent nuisance problems. Venting applications - may be installed as either 2-pipe (sealed combustion) or single-pipe vent (using indoor combustion air). See Limited Warranty certificate in Users Information Manual for details. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 400991-YTG-H-0615 LEFT SIDE RIGHT SIDE FRONT Combustion Air Inlet Condensate Drain (Downflow) Combustion Air Inlet Gas Pipe Entry Vent Outlet Gas Pipe Entry Electrical Entry Electrical Entry Condensate Drain 33 Thermostat Wiring Condensate Drain (Downflow) Vent Outlet Condensate Drain Thermostat Wiring 23” Optional Return Air Cutout (Either side) 14” 1” 28.5” 29.5” A 1.5” .56” 23.8” 3” Vent Outlet Combustion Air Inlet B .56” .56” B C 24.25” 20” RETURN END SUPPLY END Cabinet & Duct Dimensions Nominal Models Cabinet Size 3/min) CFM (m Approximate Operating Weights Cabinet Dimensions (Inches) A B C Lbs TG9S040A08MP11 800 A 14 1/2 13 3/8 11 3/4 113 TG9S060A10MP11 1000 A 14 1/2 13 3/8 11 3/4 118 TG9S060B12MP11 1200 B 17 1/2 16 3/8 13 1/4 122 TG9S080B12MP11 1200 B 17 1/2 16 3/8 14 3/4 126 TG9S080C16MP11 1600 C 21 19 7/8 16 1/2 136 TG9S080C22MP11 2200 C 21 19 7/8 16 1/2 139 TG9S100C16MP11 1600 C 21 19 7/8 18 1/4 142 TG9S100C20MP11 2000 C 21 19 7/8 18 1/4 145 TG9S120D16MP11 1600 D 24 1/2 23 3/8 21 3/4 153 TG9S120D20MP11 2000 D 24 1/2 23 3/8 21 3/4 156 TG9S130D20MP11 2000 D 24 1/2 23 3/8 No Hole 160 Ratings & Physical / Electrical Data Models Input Output AFUE % MBH MBH Air Temp. Max. Outlet Rise Air Temp Blower Blower Size Max Total Unit Over-Current Amps Protect Min. wire Size (awg) @ 75 ft one way °F °F HP Amps TG9S040A08MP11 40 38 95.5 30-60 160 1/3 4.8 11x8 15 8.0 14 TG9S060A10MP11 60 57 95.5 30-60 160 1/2 7.1 11x8 15 10.0 14 TG9S060B12MP11 60 57 95.5 30-60 160 1/2 7.1 11x8 15 10.0 14 TG9S080B12MP11 80 76 95.5 35-65 165 1/2 7.1 11x8 15 10.0 14 TG9S080C16MP11 80 76 95.5 35-65 165 3/4 8.8 11x10 15 11.5 14 TG9S080C22MP11 80 76 95.5 35-65 165 1 14.5 11x11 20 17.0 12 TG9S100C16MP11 100 95 95.5 35-65 165 3/4 8.8 11x10 15 11.5 14 TG9S100C20MP11 100 95 95.5 35-65 165 1 14.5 11x11 20 17.0 12 TG9S120D16MP11 120 114 95.5 40-70 170 3/4 8.8 11x10 15 11.5 14 TG9S120D20MP11 120 114 95.5 35-65 165 1 14.5 11x11 20 17.0 12 TG9S130D20MP11 130 123.5 95.5 45-75 175 1 14.5 11x11 20 17.0 12 Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 400991-YTG-H-0615 FILTER PERFORMANCE The airflow capacity data published in the “Blower Performance” tables shown represents blower performance WITHOUT filters. All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace. NOTICE Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a 20x25 filter. Recommended Filter Sizes (High velocity 600 FPM) Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. Eliminates unslightly elbows for a cleaner installation. S1-1CT0302 (2") & S1-1CT0302-636 (2") S1-1CT0303 (3") & S1-1CT0303-636 (3") Sidewall Vent Termination Kit - For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home. S1-1HT0901 (3") S1-1HT0902 (2") Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2" plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (p/ n 026-30228-000). 1NK0301 CFM Cabinet Size Side (in) Bottom (in) 800 A 16 x 25 14 x 25 1000 A 16 x 25 14 x 25 1200 A 16 x 25 14 x 25 1200 B 16 x 25 16 x 25 1600 B 16 x 25 16 x 25 1600 C 16 x 25 20 x 25 2000 C (2) 16 x 25 20 x 25 2200 C (2) 16 x 25 20 x 25 2000 D (2) 16 x 25 22 x 25 1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. Unit Clearances to Combustibles Application Upflow Downflow Horizontal Top 1" 0" 0" Vent 0" 0" 0" Rear 0" 0" 0" Side 0" 0" 1" Front* 0" 0" 0" Floor Combustible Combustible1 Combustible Closet Yes Yes Yes Line Contact No No Yes 1. For combustible floors only when used with special sub-base. * - 24" clearance in front and 18" on side recommended for service access. All furnaces approved for alcove and attic installation. ACCESSORIES Side Return Filter Racks S1-1SR0200 - All Models S1-1SR0402 - All Models Bottom Return Filter Racks - 1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet. S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets S1-1BR0521 or 1BR0621 - For 21” cabinets S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations.tible floor base kit provides access for combustible airflow. S1-1CB0514 - For 14-1/2” cabinets S1-1CB0517 - For 17-1/2” cabinets S1-1CB0521 - For 21” cabinets S1-1CB0524 - For 24-1/2” cabinets High Altitude Pressure Switches - For installation where the altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits below. S1-1PS3306 - 060 S1-1PS3307 - 040, 080 S1-1PS3302 - 100, 120, 130 Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls. Propane (LP) Conversion Kit - This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. S1-1NP0347 - All Models except 130K Model S1-1NP0501 - 130K Model Johnson Controls Unitary Products 3 400991-YTG-H-0615 Blower Performance CFM - Any Position (without filter) - Bottom Return Bottom Airflow Data (SCFM) Models Speed High TG9S040A08MP11 TG9S060A10MP11 TG9S060B12MP11 TG9S080B12MP11 TG9S080C16MP11 TG9S080C22MP11 TG9S100C16MP11 TG9S100C20MP11 TG9S120D16MP11 TG9S120D20MP11 TG9S130D20MP11 Ext. Static Pressure (in. H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1128 1077 1035 996 950 891 842 781 708 646 Medium High 934 909 867 834 818 780 745 696 631 584 Medium Low 746 735 714 679 653 629 596 585 547 494 Low 676 652 627 601 581 542 516 474 441 383 High 1360 1290 1230 1165 1103 1043 983 925 820 776 Medium High 1251 1198 1140 1089 1038 979 916 854 790 718 Medium Low 1081 1062 1015 964 917 871 819 767 710 634 Low 909 900 852 812 769 739 712 662 612 547 High 1492 1442 1378 1325 1243 1176 1075 966 849 655 Medium High 1236 1201 1161 1139 1082 1011 919 830 715 590 Medium Low 986 950 961 916 872 831 757 703 600 510 Low 824 795 783 744 713 659 624 554 489 389 High 1597 1537 1484 1435 1370 1286 1230 1155 1075 925 Medium High 1338 1307 1273 1223 1179 1123 1065 998 928 812 Medium Low 1113 1094 1077 1043 1008 972 924 868 803 798 Low 937 916 900 877 854 817 775 718 639 560 High 1919 1865 1802 1738 1671 1600 1517 1414 1322 1201 Medium High 1532 1533 1513 1499 1465 1416 1352 1283 1198 1084 Medium Low 1232 1313 1291 1280 1250 1209 1207 1148 1055 937 Low 826 821 853 858 838 817 794 776 760 711 High 2529 2435 2338 2256 2162 2041 1920 1794 1654 1501 Medium High 2166 2111 2070 2001 1927 1849 1719 1614 1499 1344 Medium Low 1697 1685 1664 1631 1586 1531 1466 1393 1315 1185 Low 1383 1377 1358 1336 1285 1244 1199 1147 1048 925 High 1909 1880 1823 1776 1706 1637 1562 1474 1375 1252 Medium High 1465 1463 1469 1485 1477 1416 1386 1324 1250 1114 Medium 1190 1222 1216 1215 1224 1189 1158 1145 1087 996 Low 787 834 819 836 819 810 790 761 690 707 High 2284 2205 2114 2021 1934 1848 1752 1653 1505 1397 Medium High 1967 1905 1824 1763 1712 1628 1551 1473 1379 1213 Medium Low 1610 1563 1513 1480 1430 1367 1319 1261 1101 1012 Low 1326 1304 1267 1232 1183 1143 1080 1003 871 798 High 2020 1994 1958 1878 1805 1740 1647 1560 1445 1294 Medium High 1551 1559 1549 1520 1494 1451 1383 1334 1253 1145 Medium Low 1270 1267 1269 1269 1254 1227 1185 1121 1051 985 Low 932 916 905 894 876 828 803 725 754 696 High 2341 2245 2153 2072 1977 1876 1769 1642 1506 1306 Medium High 2002 1952 1878 1823 1739 1657 1563 1458 1322 1185 Medium Low 1615 1579 1533 1473 1430 1368 1282 1186 1091 953 Low 1352 1295 1259 1245 1190 1141 1076 998 938 820 High 2412 2329 2247 2173 2047 1980 1887 1777 1655 1511 Medium High 2040 2004 1948 1876 1786 1738 1656 1562 1461 1314 Medium Low 1614 1591 1549 1531 1459 1400 1335 1267 1180 1061 Low 1327 1294 1257 1224 1198 1171 1124 1036 944 848 1. Airflow expressed in standard cubic feet per minute (CFM). 2. Motor voltage at 115 V. 4 Johnson Controls Unitary Products 400991-YTG-H-0615 Blower Performance CFM - Any Position (without filter) - Left Side Return Left Side Airflow Data (SCFM) Models TG9S040A08MP11 TG9S060A10MP11 TG9S060B12MP11 TG9S080B12MP11 TG9S080C16MP11 TG9S080C22MP11 TG9S100C16MP11 TG9S100C20MP11 TG9S120D16MP11 TG9S120D20MP11 TG9S130D20MP11 1. 2. 3. 4. Speed High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low Low High Medium High Medium Low Low Ext. Static Pressure (in. H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1131 982 772 636 1431 1280 1099 914 1470 1211 970 793 1605 1372 1087 916 1956 1543 1238 906 2585 2098 1619 1338 1828 1422 1224 813 2391 1945 1549 1256 1998 1512 1217 892 2343 1954 1596 1299 2425 1979 1582 1305 1091 959 736 618 1375 1226 1050 876 1406 1186 957 781 1562 1318 1073 896 1907 1543 1241 902 2492 2067 1628 1347 1829 1444 1229 819 2286 1878 1530 1229 1987 1506 1219 870 2253 1892 1539 1261 2336 1959 1567 1287 1053 935 715 585 1304 1171 1008 842 1361 1139 927 756 1514 1280 1052 881 1846 1516 1243 903 2405 2036 1614 1327 1789 1437 1243 818 2165 1838 1495 1189 1914 1492 1210 859 2167 1846 1511 1229 2255 1899 1540 1239 1003 887 689 569 1244 1117 970 812 1309 1101 889 724 1454 1255 1003 854 1778 1504 1241 910 2321 1982 1584 1301 1768 1424 1234 814 2079 1782 1430 1159 1858 1467 1185 843 2071 1781 1458 1177 2157 1825 1488 1194 965 846 661 546 1178 1059 919 770 1241 1042 853 694 1393 1205 993 831 1717 1477 1252 888 2232 1928 1545 1262 1727 1396 1219 783 2004 1694 1431 1089 1798 1441 1174 814 1979 1714 1399 1111 2046 1773 1443 1159 921 795 642 522 1109 1004 866 728 1155 980 796 653 1330 1161 953 802 1647 1446 1242 866 2137 1860 1488 1199 1671 1326 1193 762 1934 1642 1365 1033 1721 1406 1148 798 1881 1637 1341 1053 1966 1686 1406 1126 862 745 599 486 1040 930 814 694 1060 896 745 585 1251 1093 897 757 1573 1382 1201 859 2015 1767 1424 1138 1601 1301 1168 756 1839 1565 1284 1008 1629 1342 1112 790 1785 1548 1254 993 1865 1619 1336 1062 800 675 568 460 963 865 759 661 920 796 660 530 1169 1023 843 708 1483 1309 1140 829 1902 1670 1339 1078 1505 1253 1135 732 1692 1451 1192 950 1530 1280 1063 745 1668 1429 1180 937 1758 1516 1252 1003 733 628 531 455 861 781 710 612 775 681 568 469 1073 943 775 642 1353 1202 1074 795 1745 1549 1216 1019 1390 1200 1088 690 1560 1334 1097 871 1417 1206 1012 740 1473 1238 942 882 1615 1376 1146 943 659 595 493 370 805 731 626 545 628 545 450 382 940 849 709 574 1209 1099 967 743 1577 1331 1121 938 1272 1100 977 642 1366 1163 1022 784 1303 1097 937 677 1351 1171 988 782 1420 1225 1033 831 Airflow expressed in standard cubic feet per minute (CFM). Return air is through side opposite motor (left side). Motor voltage at 115 V. Airflow through across motor side (right side) may be slightly less than the data shown above. Johnson Controls Unitary Products 5 NOTES Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 400991-YTG-H-0615 Supersedes: 400991-YTG-G-0713
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : ckobyk Create Date : 2015:06:29 17:10:52-05:00 Modify Date : 2015:07:06 13:36:19-05:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Format : application/pdf Creator : ckobyk Title : 400991-YTG-H-0615.fm Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:07:06 13:36:19-05:00 Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:a70078f1-7304-40e0-ad47-f978903784e2 Instance ID : uuid:03164a54-1f8d-4fa8-b0fe-a99d3d96b279 Page Layout : OneColumn Page Mode : UseThumbs Page Count : 6EXIF Metadata provided by EXIF.tools