DESCRIPTION

TECHNICAL GUIDE
95.0% AFUE SINGLE STAGE ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9E
NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at

www.upgnet.com and www.york.com
Additional rating information can be found at

www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential
applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.
See Limited Warranty certificate in Users Information Manual for details.

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are
also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category IV, National Fuel Gas Code and may be
vented either through side wall or roof applications using
approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Polyflue (a polypropylene venting systems).
FEATURES
•
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•
Compact, easy to install, ideal height 33" tall cabinet.
•
Blower-off delay for cooling SEER improvement.
•
Easy access to controls to connect power/control wiring.
•
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
•
Low unit amp requirement for easy replacement application.
•
All models are convertable to use propane (LP) gas.
•
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
•
100% shut off main gas valve for extra safety.
•
5 speed, direct drive Standard ECM style high efficiency DC
motor.
•
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
•
Hi-tech tubular aluminized steel primary heat exchanger.
•
Secondary heat exchanger made of corrosion resistant
stainless steel materials.
•
Timed on, adjustable off blower capability for maximum comfort.
•
Blower door safety switch.
•
Solid removable bottom panel allows easy conversion.
•
Airflow leakage less than 1% of nominal airflow at ductblaster conditions.
•
No knockouts to deal with, making installation easier.
•
Movable duct connector flanges for application flexibility.
•
Quiet inducer operation.
•
Inducer rotates for easy conversion of venting options.
•
Fully supported blower assembly for easy access and
removal of blower.
•
External air filters used for maximum flexibility in meeting
customers IAQ needs.
•
Protection included from air intake, exhaust vent, or condensate blockage.
•
Patent pending self priming internal condensate trap design
for easy installation.
•
Venting applications - may be installed as a either 2-pipe
(sealed combustion) or single-pipe vent (using indoor combustion air.
•
No special vent termination required.
•
1/4 turn knobs provided for easy door removal.
•
High-efficiency blower motor for lower electrical power usage
and improved A/C SEER ratings.
•
Insulated blower compartment for terminal and acoustic performance.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

1104558-YTG-C-0615

LEFT SIDE

RIGHT SIDE

FRONT

Combustion Air Inlet
Condensate Drain
(Downflow)

Combustion Air Inlet

Gas Pipe
Entry

Vent Outlet

Gas Pipe
Entry

Electrical
Entry

Condensate Drain
(Downflow)

Electrical
Entry

Condensate
Drain

33

Thermostat
Wiring

Vent Outlet

Condensate
Drain
Thermostat
Wiring

23”

Optional Return Air
Cutout (Either side)

14”
1”

28.5”
29.5”

A

1.5”

.56”
23.8”

3”
Vent
Outlet

Combustion
Air Inlet

B

.56”

.56”

B
C

24.25”

20”

RETURN END

SUPPLY END

Cabinet & Duct Dimensions
Nominal

BTUH (kW)
Input

Cabinet
Size

3/min)

CFM (m

Cabinet Dimensions (Inches)

Approximate
Operating Weights

A

B

C

TM9E040A10MP11

1000

A

14-1/2

13-3/8

11-3/4

Lbs
113

TM9E060B12MP11

1200

B

17-1/2

16-3/8

13-1/4

122

TM9E080B12MP11

1200

B

17-1/2

16-3/8

14-3/4

126

TM9E080C16MP11

1600

C

21

19-7/8

16-1/2

136

TM9E100C16MP11

1600

C

21

19-7/8

18-1/4

142

TM9E100C20MP11

2000

C

21

19-7/8

18-1/4

145

TM9E120D20MP11

2000

D

24-1/2

23-3/8

21-3/4

156

Ratings & Physical / Electrical Data
Nominal
AFUE
Airflow

Air Temp. Max. Outlet
Rise
Air Temp

Blower

Max
Min. wire Size
Blower
Total Unit
Over-Current
(awg) @ 75 ft
Size
Amps
Protect
one way

BTUH (kW)
Input

Output
MBH

CFM

%

°F

°F

HP

Amps

TM9E040A10MP11

38

1000

95.0

45-75

180

1/2

6.8

11x8

15

9.5

14

TM9E060B12MP11

57

1200

95.0

40-70

180

1/2

6.8

11x8

15

9.5

14

TM9E080B12MP11

76

1200

95.0

50-80

170

1/2

6.8

11x8

15

9.5

14

TM9E080C16MP11

76

1600

95.0

40-70

165

1/2

6.8

11x10

15

9.5

14

TM9E100C16MP11

95

1600

95.0

45-75

170

1/2

6.8

11x10

15

9.5

14

TM9E100C20MP11

95

2000

95.0

50-80

165

3/4

8.4

11x11

15

10.9

14

TM9E120D20MP11

114

2000

95.0

50-80

175

3/4

8.4

11x11

15

10.9

14

NOTES:

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

1104558-YTG-C-0615

FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.

NOTICE
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a
20x25 filter.

S1-1CT0302 (2") & S1-1CT0302-636 (2")
S1-1CT0303 (3") & S1-1CT0303-636 (3")
Sidewall Vent Termination Kit - For use on sidewall, two-pipe
installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home.
S1-1HT0901 (3")
S1-1HT0902 (2")
Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2"
plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts
(P/N 026-30228-000).
1NK0301

Recommended Filter Sizes (High velocity 600 FPM)
CFM

Cabinet
Size

Side
(in)

Bottom
(in)

1000

A

16 x 25

14 x 25

1200

B

16 x 25

16 x 25

1600

C

16 x 25

20 x 25

2000

C

(2) 16 x 25

20 x 25

2000

D

(2) 16 x 25

22 x 25

NOTES:

1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.

Unit Clearances to Combustibles
Application

Upflow

Downflow

Horizontal

Top

1"

0"

0"

Vent

0"

0"

0"

Rear

0"

0"

0"

Side

0"

0"

1"

Front*

0"

0"

0"
1

Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through
single common hole. Eliminates unslightly elbows for a cleaner
installation.

Combustible

Floor

Combustible

Combustible

Closet

Yes

Yes

Yes

Line Contact

No

No

Yes

NOTES:

1. For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service access.
All furnaces approved for alcove and attic installation.

ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas (N) units for propane (LP)
operation.

Side Return Filter Racks S1-1SR0200 - All Models
S1-1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential
overheating situations.tible floor base kit provides access for
combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
S1-1CB0524 - For 24-1/2” cabinets
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
S1-1PS3306 - 060
S1-1PS3307 - 040, 080
S1-1PS3302 - 100, 120
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.

S1-1NP0347 - All Models

Johnson Controls Unitary Products

3

Blower Performance CFM - Any Position (without filter)
Bottom Airflow Data (SCFM)1,2
Models

TM9E040A12MP11

TM9E060B12MP11

TM9E080B12MP11

TM9E080C16MP11

TM9E100C16MP11

TM9E100C20MP11

TM9E120D20MP11

Speed

Ext. Static Pressure (in. H2O)
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

High

1290

1260

1220

1160

1100

1040

960

840

750

660

Medium High

1170

1140

1110

1070

1040

990

930

820

730

650

Medium

990

980

940

900

860

830

790

730

680

630

Medium Low

900

880

850

810

770

730

670

630

600

560

Low

730

710

690

650

620

590

540

510

480

450

High

1402

1374

1354

1328

1299

1262

1222

1167

1107

1036

Medium High

1252

1233

1203

1182

1150

1125

1095

1064

1031

980

Medium

1076

1059

1029

1007

973

946

908

883

843

800

Medium Low

988

967

936

903

875

838

806

765

737

685

Low

798

769

727

695

650

619

574

517

485

443

High

1445

1423

1397

1365

1339

1311

1283

1250

1204

1140
1013

Medium High

1282

1266

1232

1211

1182

1157

1128

1097

1069

Medium

1098

1084

1059

1027

998

967

939

910

879

822

Medium Low

1012

993

953

930

894

851

828

773

752

692

Low

865

810

763

730

689

628

594

520

496

448

High

1713

1682

1643

1600

1558

1519

1480

1436

1385

1333
1130

Medium High

1554

1519

1485

1439

1404

1368

1327

1280

1176

Medium

1380

1351

1302

1263

1224

1171

1128

1085

1030

943

Medium Low

1177

1142

1083

1050

988

922

890

819

798

687

Low

951

841

650

588

457

418

355

227

203

N/A

High

1734

1694

1650

1611

1570

1536

1485

1438

1392

1335
1118

Medium High

1568

1537

1492

1453

1414

1373

1327

1279

1230

Medium

1420

1380

1332

1294

1249

1196

1152

1100

981

938

Medium

1218

1169

1124

1067

1015

965

894

845

754

679

Low

979

846

647

580

464

427

345

220

195

N/A

High

2143

2102

2065

2028

1989

1944

1892

1825

1733

1625

Medium High

1788

1749

1718

1672

1629

1587

1541

1500

1447

1355

Medium

1575

1539

1500

1456

1410

1363

1305

1246

1095

1030

Medium Low

1372

1325

1276

1225

1170

1111

1044

972

884

812

Low

1031

921

810

728

660

615

518

474

391

355

High

2214

2173

2132

2086

2036

1994

1952

1907

1849

1777

Medium High

1841

1799

1749

1699

1659

1611

1567

1520

1471

1372

Medium

1605

1562

1514

1470

1416

1361

1310

1180

1119

1045

Medium Low

1405

1362

1303

1244

1189

1125

1054

986

876

826

Low

1135

1020

844

758

671

557

511

464

387

N/A

NOTES:

1. Airflow expressed in standard cubic feet per minute (SCFM).
2. Motor voltage at 115 V.

Subject to change without notice. Published in U.S.A.
Copyright © 2015 by Johnson Controls, Inc. All rights reserved.

York International Corp.
5005 York Drive
Norman, OK 73069

1104558-YTG-C-0615
Supersedes: 1104558-YTG-B-0714



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : ckobyk
Create Date                     : 2015:06:29 17:51:56-05:00
Modify Date                     : 2015:07:06 13:37:43-05:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Title                           : 1104558-YTG-C-0615.fm
Creator                         : ckobyk
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:07:06 13:37:43-05:00
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:633b26dd-e6a9-43e6-aa85-f3dbc6efb4e5
Instance ID                     : uuid:25c19e39-3751-43e1-94c4-0af4a23c29a9
Page Layout                     : OneColumn
Page Mode                       : UseThumbs
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu