1104558-YTG-C-0615 DESCRIPTION TECHNICAL GUIDE 95.0% AFUE SINGLE STAGE ECM RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TM9E NATURAL GAS 40 - 120 MBH INPUT Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at www.ahridirectory.org WARRANTY SUMMARY A 20-year limited warranty on heat exchangers in residential applications. A 10-year warranty on the heat exchanger in commercial applications. Standard 5-year limited Parts warranty. Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. See Limited Warranty certificate in Users Information Manual for details. These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV, National Fuel Gas Code and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Polyflue (a polypropylene venting systems). FEATURES • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. • Compact, easy to install, ideal height 33" tall cabinet. • Blower-off delay for cooling SEER improvement. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation. • Low unit amp requirement for easy replacement application. • All models are convertable to use propane (LP) gas. • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. • 100% shut off main gas valve for extra safety. • 5 speed, direct drive Standard ECM style high efficiency DC motor. • 24V, 40 VA control transformer and blower relay supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger. • Secondary heat exchanger made of corrosion resistant stainless steel materials. • Timed on, adjustable off blower capability for maximum comfort. • Blower door safety switch. • Solid removable bottom panel allows easy conversion. • Airflow leakage less than 1% of nominal airflow at ductblaster conditions. • No knockouts to deal with, making installation easier. • Movable duct connector flanges for application flexibility. • Quiet inducer operation. • Inducer rotates for easy conversion of venting options. • Fully supported blower assembly for easy access and removal of blower. • External air filters used for maximum flexibility in meeting customers IAQ needs. • Protection included from air intake, exhaust vent, or condensate blockage. • Patent pending self priming internal condensate trap design for easy installation. • Venting applications - may be installed as a either 2-pipe (sealed combustion) or single-pipe vent (using indoor combustion air. • No special vent termination required. • 1/4 turn knobs provided for easy door removal. • High-efficiency blower motor for lower electrical power usage and improved A/C SEER ratings. • Insulated blower compartment for terminal and acoustic performance. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 1104558-YTG-C-0615 LEFT SIDE RIGHT SIDE FRONT Combustion Air Inlet Condensate Drain (Downflow) Combustion Air Inlet Gas Pipe Entry Vent Outlet Gas Pipe Entry Electrical Entry Condensate Drain (Downflow) Electrical Entry Condensate Drain 33 Thermostat Wiring Vent Outlet Condensate Drain Thermostat Wiring 23” Optional Return Air Cutout (Either side) 14” 1” 28.5” 29.5” A 1.5” .56” 23.8” 3” Vent Outlet Combustion Air Inlet B .56” .56” B C 24.25” 20” RETURN END SUPPLY END Cabinet & Duct Dimensions Nominal BTUH (kW) Input Cabinet Size 3/min) CFM (m Cabinet Dimensions (Inches) Approximate Operating Weights A B C TM9E040A10MP11 1000 A 14-1/2 13-3/8 11-3/4 Lbs 113 TM9E060B12MP11 1200 B 17-1/2 16-3/8 13-1/4 122 TM9E080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 126 TM9E080C16MP11 1600 C 21 19-7/8 16-1/2 136 TM9E100C16MP11 1600 C 21 19-7/8 18-1/4 142 TM9E100C20MP11 2000 C 21 19-7/8 18-1/4 145 TM9E120D20MP11 2000 D 24-1/2 23-3/8 21-3/4 156 Ratings & Physical / Electrical Data Nominal AFUE Airflow Air Temp. Max. Outlet Rise Air Temp Blower Max Min. wire Size Blower Total Unit Over-Current (awg) @ 75 ft Size Amps Protect one way BTUH (kW) Input Output MBH CFM % °F °F HP Amps TM9E040A10MP11 38 1000 95.0 45-75 180 1/2 6.8 11x8 15 9.5 14 TM9E060B12MP11 57 1200 95.0 40-70 180 1/2 6.8 11x8 15 9.5 14 TM9E080B12MP11 76 1200 95.0 50-80 170 1/2 6.8 11x8 15 9.5 14 TM9E080C16MP11 76 1600 95.0 40-70 165 1/2 6.8 11x10 15 9.5 14 TM9E100C16MP11 95 1600 95.0 45-75 170 1/2 6.8 11x10 15 9.5 14 TM9E100C20MP11 95 2000 95.0 50-80 165 3/4 8.4 11x11 15 10.9 14 TM9E120D20MP11 114 2000 95.0 50-80 175 3/4 8.4 11x11 15 10.9 14 NOTES: Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 1104558-YTG-C-0615 FILTER PERFORMANCE The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT filters. All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace. NOTICE Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a 20x25 filter. S1-1CT0302 (2") & S1-1CT0302-636 (2") S1-1CT0303 (3") & S1-1CT0303-636 (3") Sidewall Vent Termination Kit - For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home. S1-1HT0901 (3") S1-1HT0902 (2") Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2" plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (P/N 026-30228-000). 1NK0301 Recommended Filter Sizes (High velocity 600 FPM) CFM Cabinet Size Side (in) Bottom (in) 1000 A 16 x 25 14 x 25 1200 B 16 x 25 16 x 25 1600 C 16 x 25 20 x 25 2000 C (2) 16 x 25 20 x 25 2000 D (2) 16 x 25 22 x 25 NOTES: 1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. Unit Clearances to Combustibles Application Upflow Downflow Horizontal Top 1" 0" 0" Vent 0" 0" 0" Rear 0" 0" 0" Side 0" 0" 1" Front* 0" 0" 0" 1 Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. Eliminates unslightly elbows for a cleaner installation. Combustible Floor Combustible Combustible Closet Yes Yes Yes Line Contact No No Yes NOTES: 1. For combustible floors only when used with special sub-base. * - 24" clearance in front and 18" on side recommended for service access. All furnaces approved for alcove and attic installation. ACCESSORIES Propane (LP) Conversion Kit - This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. Side Return Filter Racks S1-1SR0200 - All Models S1-1SR0402 - All Models Bottom Return Filter Racks - 1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet. S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets S1-1BR0521 or 1BR0621 - For 21” cabinets S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations.tible floor base kit provides access for combustible airflow. S1-1CB0514 - For 14-1/2” cabinets S1-1CB0517 - For 17-1/2” cabinets S1-1CB0521 - For 21” cabinets S1-1CB0524 - For 24-1/2” cabinets High Altitude Pressure Switches - For installation where the altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits below. S1-1PS3306 - 060 S1-1PS3307 - 040, 080 S1-1PS3302 - 100, 120 Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls. S1-1NP0347 - All Models Johnson Controls Unitary Products 3 Blower Performance CFM - Any Position (without filter) Bottom Airflow Data (SCFM)1,2 Models TM9E040A12MP11 TM9E060B12MP11 TM9E080B12MP11 TM9E080C16MP11 TM9E100C16MP11 TM9E100C20MP11 TM9E120D20MP11 Speed Ext. Static Pressure (in. H2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 1290 1260 1220 1160 1100 1040 960 840 750 660 Medium High 1170 1140 1110 1070 1040 990 930 820 730 650 Medium 990 980 940 900 860 830 790 730 680 630 Medium Low 900 880 850 810 770 730 670 630 600 560 Low 730 710 690 650 620 590 540 510 480 450 High 1402 1374 1354 1328 1299 1262 1222 1167 1107 1036 Medium High 1252 1233 1203 1182 1150 1125 1095 1064 1031 980 Medium 1076 1059 1029 1007 973 946 908 883 843 800 Medium Low 988 967 936 903 875 838 806 765 737 685 Low 798 769 727 695 650 619 574 517 485 443 High 1445 1423 1397 1365 1339 1311 1283 1250 1204 1140 1013 Medium High 1282 1266 1232 1211 1182 1157 1128 1097 1069 Medium 1098 1084 1059 1027 998 967 939 910 879 822 Medium Low 1012 993 953 930 894 851 828 773 752 692 Low 865 810 763 730 689 628 594 520 496 448 High 1713 1682 1643 1600 1558 1519 1480 1436 1385 1333 1130 Medium High 1554 1519 1485 1439 1404 1368 1327 1280 1176 Medium 1380 1351 1302 1263 1224 1171 1128 1085 1030 943 Medium Low 1177 1142 1083 1050 988 922 890 819 798 687 Low 951 841 650 588 457 418 355 227 203 N/A High 1734 1694 1650 1611 1570 1536 1485 1438 1392 1335 1118 Medium High 1568 1537 1492 1453 1414 1373 1327 1279 1230 Medium 1420 1380 1332 1294 1249 1196 1152 1100 981 938 Medium 1218 1169 1124 1067 1015 965 894 845 754 679 Low 979 846 647 580 464 427 345 220 195 N/A High 2143 2102 2065 2028 1989 1944 1892 1825 1733 1625 Medium High 1788 1749 1718 1672 1629 1587 1541 1500 1447 1355 Medium 1575 1539 1500 1456 1410 1363 1305 1246 1095 1030 Medium Low 1372 1325 1276 1225 1170 1111 1044 972 884 812 Low 1031 921 810 728 660 615 518 474 391 355 High 2214 2173 2132 2086 2036 1994 1952 1907 1849 1777 Medium High 1841 1799 1749 1699 1659 1611 1567 1520 1471 1372 Medium 1605 1562 1514 1470 1416 1361 1310 1180 1119 1045 Medium Low 1405 1362 1303 1244 1189 1125 1054 986 876 826 Low 1135 1020 844 758 671 557 511 464 387 N/A NOTES: 1. Airflow expressed in standard cubic feet per minute (SCFM). 2. Motor voltage at 115 V. Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 1104558-YTG-C-0615 Supersedes: 1104558-YTG-B-0714
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : ckobyk Create Date : 2015:06:29 17:51:56-05:00 Modify Date : 2015:07:06 13:37:43-05:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Format : application/pdf Title : 1104558-YTG-C-0615.fm Creator : ckobyk Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:07:06 13:37:43-05:00 Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:633b26dd-e6a9-43e6-aa85-f3dbc6efb4e5 Instance ID : uuid:25c19e39-3751-43e1-94c4-0af4a23c29a9 Page Layout : OneColumn Page Mode : UseThumbs Page Count : 4EXIF Metadata provided by EXIF.tools