700706-YTG-G-0615 DESCRIPTION 96% AFUE TWO STAGE VARIABLE SPEED ECM RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TM9V*C These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV, National Fuel Gas Code and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Polyflue (a polypropylene venting systems). NATURAL GAS 40 - 120 MBH INPUT FEATURES TECHNICAL GUIDE • • • • • • • • • • • • • • Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at • • • • • • www.ahridirectory.org • WARRANTY SUMMARY A 20-year limited warranty on heat exchangers in residential applications. A 10-year warranty on the heat exchanger in commercial applications. Standard 5-year limited Parts warranty. Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. • • See Limited Warranty certificate in Users Information Manual for details. • • • Two stage heating operation includes two stage gas valve, two stage inducer operation and variable speed ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat. Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. Compact, easy to install, ideal height 33" tall cabinet. ECM variable speed drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance. Easy access to controls to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. All models are convertible to use propane (LP) gas. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. 100% shut off main gas valve for extra safety. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency. Solid removable bottom panel allows easy conversion. Airflow leakage less than 1% of nominal airflow for duct blaster conditions. No knockouts to deal with, making installation easier. Movable duct connector flanges for application flexibility. Quiet inducer operation, burner, and blower operation. Inducer rotates for easy conversion of venting options. Fully supported blower assembly for easy access and removal of blower. External air filters used for maximum flexibility in meeting customers IAQ needs. Insulated blower compartment for thermal and acoustic performance. 1/4 turn knobs provided for easy independent door removal. Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems. Protection included from air intake, exhaust vent or condensate blockage. Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air. These models may be connected as part of a communicating control system using a 4-wire connection bus. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 700706-YTG-G-0615 LEFT SIDE RIGHT SIDE FRONT Combustion Air Inlet Condensate Drain (Downflow) Combustion Air Inlet Gas Pipe Entry Vent Outlet Gas Pipe Entry Electrical Entry Condensate Drain (Downflow) Electrical Entry Condensate Drain 33 Thermostat Wiring Vent Outlet Condensate Drain 23” Thermostat Wiring Optional Return Air Cutout (Either side) 14” 1” 28.5” 29.5” A 1.5” .56” 23.8” 3” Vent Outlet Combustion Air Inlet B .56” .56” B C 24.25” 20” RETURN END SUPPLY END Cabinet & Duct Dimensions Model Nominal CFM (m3/min) Cabinet Size 1000 1200 1200 1600 1600 2000 2000 A B B C C C D TM9V040A10MP11C TM9V060B12MP11C TM9V080B12MP11C TM9V080C16MP11C TM9V100C16MP11C TM9V100C20MP11C TM9V120D20MP11C Approximate Operating Weights Cabinet Dimensions (Inches) A B C Lbs 14-1/2 17-1/2 17-1/2 21 21 21 24-1/2 13-3/8 16-3/8 16-3/8 19-7/8 19-7/8 19-7/8 23-3/8 11-3/4 13-1/4 13-1/4 16-1/2 18-1/4 18-1/4 21-3/4 113 122 126 136 142 145 156 Ratings & Physical / Electrical Data Model Input High/Low Output High/Low Total Unit TM9V040A10MP11C TM9V060B12MP11C TM9V080B12MP11C TM9V080C16MP11C TM9V100C16MP11C TM9V100C20MP11C TM9V120D20MP11C MBH MBH Amps % °F °F 40/26 60/39 80/52 80/52 100/65 100/65 120/78 38/25 58/37 77/50 77/50 96/62 96/62 115/75 9 9 9 12 12 14 14 96 96 96 96 96 96 96 30 - 60 35 - 65 40 - 70 35 - 65 35 - 65 35 - 65 35 - 65 20 - 50 35 - 65 35 - 65 35 - 65 30 - 65 35 - 65 35 - 65 Model Max. Outlet Air Temp. Blower Size In. Max. Over-current Protect Min. Wire Size (awg) @ 75 ft. One Way °F HP Amps TM9V040A10MP11C TM9V060B12MP11C TM9V080B12MP11C TM9V080C16MP11C TM9V100C16MP11C TM9V100C20MP11C TM9V120D20MP11C 180 180 175 165 180 170 180 1/2 1/2 1/2 3/4 3/4 1 1 7 7 7 10.2 10.2 12.7 12.7 11 X 8 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11 11 x 11 15 15 15 15 15 20 20 14 14 14 14 14 12 12 Blower AFUE High Fire Air Temp. Rise Low Fire Air Temp. Rise Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 700706-YTG-G-0615 FILTER PERFORMANCE The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT filters. All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace. NOTICE Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a 20x25 filter. S1-1CT0302 (2") & S1-1CT0302-636 (2") S1-1CT0303 (3") & S1-1CT0303-636 (3") Sidewall Vent Termination Kit - For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visible on the side of the home. S1-1HT0901 (3") S1-1HT0902 (2") Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2” plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (P/N 026-30228-000). 1NK0301 Recommended Filter Sizes (High velocity 600 FPM) CFM Cabinet Size Side (in) Bottom (in) 1000 A 16 x 25 14 x 25 1200 B 16 x 25 16 x 25 1600 C 16 x 25 20 x 25 2000 C (2) 16 x 25 20 x 25 2000 D (2) 16 x 25 22 x 25 1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. Unit Clearances to Combustibles Application Upflow Downflow Horizontal Top 1" 0" 0" Vent 0" 0" 0" Rear 0" 0" 0" Side 0" 0" 1" Front* 0" 0" 0" 1 Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. Eliminates unsightly elbows for a cleaner installation. Combustible Floor Combustible Combustible Closet Yes Yes Yes Line Contact No No Yes 1. For combustible floors only when used with special sub-base. * - 24" clearance in front and 18" on side recommended for service access. All furnaces approved for alcove and attic installation. ACCESSORIES Side Return Filter Racks S1-1SR0200 - All Models S1-1SR0402 - All Models Bottom Return Filter Racks - 1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet. S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets S1-1BR0521 or 1BR0621 - For 21” cabinets S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations.tible floor base kit provides access for combustible airflow. S1-1CB0514 - For 14-1/2” cabinets S1-1CB0517 - For 17-1/2” cabinets S1-1CB0521 - For 21” cabinets S1-1CB0524 - For 24-1/2” cabinets High Altitude Pressure Switches - For installation where the altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits below. S1-1PS3308 - All Models Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these indoor units are fully compatible with the Residential Touchscreen Communicating Control S1-TTSCC01. Propane (LP) Conversion Kit - This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. S1-1NP0347 - All Models Johnson Controls Unitary Products 3 Air Flow Data 040A10 High 1073 957 975 870 878 770 783 649 700 590 630 531 Low 704 622 640 565 576 501 509 440 455 400 410 400 080C16 High 1760 1540 1600 1400 1440 1320 1260 1100 1200 1000 1080 900 Low 1144 1001 1040 910 936 858 819 715 780 650 702 585 040A10 High 890 790 711 646 Low 770 660 578 514 080C16 High 1580 1422 1293 1185 Low 1156 1027 924 840 HIGH / LOW SPEED COOLING AND HEAT PUMP CFM 060B12 080B12 High Low High Low 1320 858 1320 858 1100 715 1100 715 1200 780 1200 780 1000 650 1000 650 1080 702 1080 702 880 572 880 572 900 585 900 585 660 440 660 440 800 520 800 520 600 400 600 400 720 468 720 468 540 400 540 400 100C16 100C20 High Low High Low 1760 1144 2200 1430 1540 1001 1760 1144 1600 1040 2000 1300 1400 910 1600 1040 1440 936 1800 1170 1320 858 1540 1001 1260 819 1440 936 1100 715 1320 858 1200 780 1400 910 1000 650 1200 780 1080 702 1260 819 900 585 1080 702 120D20 High Low 2200 1430 1760 1144 2000 1300 1600 1040 1800 1170 1540 1001 1440 936 1320 858 1400 910 1200 780 1260 819 1080 702 HIGH/LOW HEAT CFM 060B12 080B12 High Low High Low 1200 870 1366 1156 1070 770 1293 1022 970 693 1185 924 890 630 1094 840 100C16 100C20 High Low High Low 1975 1444 1975 1284 1778 1284 1778 1156 1616 1156 1616 1050 1481 1050 1481 963 120D20 High Low 2250 1539 2133 1385 1939 1259 1778 1154 Jumper Settings COOL Tap ADJ Tap A B B B A A B A A C C B B C D B C A D A C C D C Jumper Settings COOL Tap ADJ Tap A B B B A A B A A C C B B C D B C A D A C C D C Jumper Settings COOL Tap ADJ Tap A B B B A A B A A C C B B C D B C A D A C C D C Jumper Settings HEAT Tap ADJ Tap A Any B Any C Any D Any Jumper Settings HEAT Tap ADJ Tap A Any B Any C Any D Any Jumper Settings HEAT Tap ADJ Tap A Any B Any C Any D Any All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended. NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details. * The ADJ “D” tap should not be used. Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 700706-YTG-G-0615 Supersedes: 700706-YTG-F-0315
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : csardom Create Date : 2015:06:30 14:10:44-05:00 Modify Date : 2015:07:06 13:37:21-05:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:07:06 13:37:21-05:00 Format : application/pdf Title : 700706-YTG-G-0615.fm Creator : csardom Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:7dec1dd7-ad3d-4664-aab6-822ef90b0ef2 Instance ID : uuid:526e8396-4d54-478b-9f7a-4c4e583df3f3 Page Layout : OneColumn Page Mode : UseThumbs Page Count : 4EXIF Metadata provided by EXIF.tools