York Tm9V Technical Guide 700706 YTG G 0615

2015-09-09

: York Tm9V-Technical-Guide york-tm9v-technical-guide-811962 york pdf

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadYork Tm9V-Technical-Guide 700706-YTG-G-0615  York-tm9v-technical-guide
Open PDF In BrowserView PDF
700706-YTG-G-0615

DESCRIPTION

96% AFUE TWO STAGE VARIABLE SPEED ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9V*C

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV, National Fuel Gas Code and may
be vented either through side wall or roof applications using
approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Polyflue (a polypropylene venting systems).

NATURAL GAS
40 - 120 MBH INPUT

FEATURES

TECHNICAL GUIDE

•

•
•
•

•
•
•
•
•
•
•
•

•
•

Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at

•
•
•
•
•
•

www.ahridirectory.org
•

WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.

•
•

See Limited Warranty certificate in Users Information Manual for details.

•

•
•

Two stage heating operation includes two stage gas valve,
two stage inducer operation and variable speed ECM
blower operation. Adjustable delay timer allows two stage
operation with a single stage thermostat.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertible to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for duct
blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent or condensate blockage.
Venting applications maybe installed as either 2 pipe sealed
combustion or single pipe vent using indoor combustion air.
These models may be connected as part of a communicating control system using a 4-wire connection bus.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

700706-YTG-G-0615
LEFT SIDE

RIGHT SIDE

FRONT

Combustion Air Inlet
Condensate Drain
(Downflow)

Combustion Air Inlet

Gas Pipe
Entry

Vent Outlet

Gas Pipe
Entry

Electrical
Entry

Condensate Drain
(Downflow)

Electrical
Entry

Condensate
Drain

33

Thermostat
Wiring

Vent Outlet

Condensate
Drain

23”

Thermostat
Wiring

Optional Return Air
Cutout (Either side)

14”
1”

28.5”
29.5”

A

1.5”

.56”
23.8”

3”
Vent
Outlet

Combustion
Air Inlet

B

.56”

.56”

B
C

24.25”

20”

RETURN END

SUPPLY END

Cabinet & Duct Dimensions
Model

Nominal
CFM (m3/min)

Cabinet
Size

1000
1200
1200
1600
1600
2000
2000

A
B
B
C
C
C
D

TM9V040A10MP11C
TM9V060B12MP11C
TM9V080B12MP11C
TM9V080C16MP11C
TM9V100C16MP11C
TM9V100C20MP11C
TM9V120D20MP11C

Approximate
Operating Weights

Cabinet Dimensions (Inches)
A

B

C

Lbs

14-1/2
17-1/2
17-1/2
21
21
21
24-1/2

13-3/8
16-3/8
16-3/8
19-7/8
19-7/8
19-7/8
23-3/8

11-3/4
13-1/4
13-1/4
16-1/2
18-1/4
18-1/4
21-3/4

113
122
126
136
142
145
156

Ratings & Physical / Electrical Data
Model

Input
High/Low

Output
High/Low

Total
Unit

TM9V040A10MP11C
TM9V060B12MP11C
TM9V080B12MP11C
TM9V080C16MP11C
TM9V100C16MP11C
TM9V100C20MP11C
TM9V120D20MP11C

MBH

MBH

Amps

%

°F

°F

40/26
60/39
80/52
80/52
100/65
100/65
120/78

38/25
58/37
77/50
77/50
96/62
96/62
115/75

9
9
9
12
12
14
14

96
96
96
96
96
96
96

30 - 60
35 - 65
40 - 70
35 - 65
35 - 65
35 - 65
35 - 65

20 - 50
35 - 65
35 - 65
35 - 65
30 - 65
35 - 65
35 - 65

Model

Max. Outlet
Air Temp.

Blower Size
In.

Max.
Over-current
Protect

Min. Wire Size
(awg) @ 75 ft.
One Way

°F

HP

Amps

TM9V040A10MP11C
TM9V060B12MP11C
TM9V080B12MP11C
TM9V080C16MP11C
TM9V100C16MP11C
TM9V100C20MP11C
TM9V120D20MP11C

180
180
175
165
180
170
180

1/2
1/2
1/2
3/4
3/4
1
1

7
7
7
10.2
10.2
12.7
12.7

11 X 8
11 x 8
11 x 8
11 x 10
11 x 10
11 x 11
11 x 11

15
15
15
15
15
20
20

14
14
14
14
14
12
12

Blower

AFUE

High Fire
Air Temp. Rise

Low Fire
Air Temp. Rise

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

700706-YTG-G-0615

FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.

NOTICE
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a
20x25 filter.

S1-1CT0302 (2") & S1-1CT0302-636 (2")
S1-1CT0303 (3") & S1-1CT0303-636 (3")
Sidewall Vent Termination Kit - For use on sidewall, two-pipe
installations only. Provide a more attractive termination for locations where the terminal is visible on the side of the home.
S1-1HT0901 (3")
S1-1HT0902 (2")
Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2”
plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts
(P/N 026-30228-000).
1NK0301

Recommended Filter Sizes (High velocity 600 FPM)
CFM

Cabinet
Size

Side
(in)

Bottom
(in)

1000

A

16 x 25

14 x 25

1200

B

16 x 25

16 x 25

1600

C

16 x 25

20 x 25

2000

C

(2) 16 x 25

20 x 25

2000

D

(2) 16 x 25

22 x 25

1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.

Unit Clearances to Combustibles
Application

Upflow

Downflow

Horizontal

Top

1"

0"

0"

Vent

0"

0"

0"

Rear

0"

0"

0"

Side

0"

0"

1"

Front*

0"

0"

0"
1

Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through
single common hole. Eliminates unsightly elbows for a cleaner
installation.

Combustible

Floor

Combustible

Combustible

Closet

Yes

Yes

Yes

Line Contact

No

No

Yes

1. For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service
access.
All furnaces approved for alcove and attic installation.

ACCESSORIES

Side Return Filter Racks S1-1SR0200 - All Models
S1-1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential
overheating situations.tible floor base kit provides access for
combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
S1-1CB0524 - For 24-1/2” cabinets
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
S1-1PS3308 - All Models
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
indoor units are fully compatible with the Residential Touchscreen Communicating Control S1-TTSCC01.

Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas (N) units for propane (LP)
operation.
S1-1NP0347 - All Models

Johnson Controls Unitary Products

3

Air Flow Data
040A10
High
1073
957
975
870
878
770
783
649
700
590
630
531

Low
704
622
640
565
576
501
509
440
455
400
410
400
080C16

High
1760
1540
1600
1400
1440
1320
1260
1100
1200
1000
1080
900

Low
1144
1001
1040
910
936
858
819
715
780
650
702
585

040A10
High
890
790
711
646

Low
770
660
578
514
080C16

High
1580
1422
1293
1185

Low
1156
1027
924
840

HIGH / LOW SPEED COOLING AND HEAT PUMP CFM
060B12
080B12
High
Low
High
Low
1320
858
1320
858
1100
715
1100
715
1200
780
1200
780
1000
650
1000
650
1080
702
1080
702
880
572
880
572
900
585
900
585
660
440
660
440
800
520
800
520
600
400
600
400
720
468
720
468
540
400
540
400
100C16
100C20
High
Low
High
Low
1760
1144
2200
1430
1540
1001
1760
1144
1600
1040
2000
1300
1400
910
1600
1040
1440
936
1800
1170
1320
858
1540
1001
1260
819
1440
936
1100
715
1320
858
1200
780
1400
910
1000
650
1200
780
1080
702
1260
819
900
585
1080
702
120D20
High
Low
2200
1430
1760
1144
2000
1300
1600
1040
1800
1170
1540
1001
1440
936
1320
858
1400
910
1200
780
1260
819
1080
702
HIGH/LOW HEAT CFM
060B12
080B12
High
Low
High
Low
1200
870
1366
1156
1070
770
1293
1022
970
693
1185
924
890
630
1094
840
100C16
100C20
High
Low
High
Low
1975
1444
1975
1284
1778
1284
1778
1156
1616
1156
1616
1050
1481
1050
1481
963
120D20
High
Low
2250
1539
2133
1385
1939
1259
1778
1154

Jumper Settings
COOL Tap
ADJ Tap
A
B
B
B
A
A
B
A
A
C
C
B
B
C
D
B
C
A
D
A
C
C
D
C
Jumper Settings
COOL Tap
ADJ Tap
A
B
B
B
A
A
B
A
A
C
C
B
B
C
D
B
C
A
D
A
C
C
D
C
Jumper Settings
COOL Tap
ADJ Tap
A
B
B
B
A
A
B
A
A
C
C
B
B
C
D
B
C
A
D
A
C
C
D
C
Jumper Settings
HEAT Tap
ADJ Tap
A
Any
B
Any
C
Any
D
Any
Jumper Settings
HEAT Tap
ADJ Tap
A
Any
B
Any
C
Any
D
Any
Jumper Settings
HEAT Tap
ADJ Tap
A
Any
B
Any
C
Any
D
Any

All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6”
w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external
static pressure is not recommended.
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air
cleaners. Consult the instructions for the electronic air cleaner for further details.
* The ADJ “D” tap should not be used.

Subject to change without notice. Published in U.S.A.
Copyright © 2015 by Johnson Controls, Inc. All rights reserved.

York International Corp.
5005 York Drive
Norman, OK 73069

700706-YTG-G-0615
Supersedes: 700706-YTG-F-0315



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : csardom
Create Date                     : 2015:06:30 14:10:44-05:00
Modify Date                     : 2015:07:06 13:37:21-05:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:07:06 13:37:21-05:00
Format                          : application/pdf
Title                           : 700706-YTG-G-0615.fm
Creator                         : csardom
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:7dec1dd7-ad3d-4664-aab6-822ef90b0ef2
Instance ID                     : uuid:526e8396-4d54-478b-9f7a-4c4e583df3f3
Page Layout                     : OneColumn
Page Mode                       : UseThumbs
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu