DESCRIPTION

TECHNICAL GUIDE
96% AFUE TWO STAGE STANDARD ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9Y

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized steel tubular
primary heat exchangers. The units are factory shipped for
installation in upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.

FEATURES

NATURAL GAS
40 - 120 MBH INPUT

•

•
•
•

•
•
•
•
•
•
•
•

•
•

Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at

www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closing for new
home construction.

•
•
•
•
•
•
•
•
•

•
•

Two stage heating operation includes two stage gas valve,
two stage inducer operation and constant torque standard
ECM blower operation. Adjustable delay timer allows two
stage operation with a single stage thermostat.
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Standard ECM constant torque drive for cooling SEER
enhancement, improved comfort with optional airflow delay
profiles, and continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit current draw requirement for easy replacement
application.
All models are convertible to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel use with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and integrated furnace control supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for duct
blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Insulated blower compartment for thermal and acoustic performance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent or condensate blockage.
Venting applications maybe installed as either 2 pipe sealed
combustion or single pipe vent using indoor combustion air.

See Limited Warranty certificate in Users Information Manual for details.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

5129599-YTG-A-0815
LEFT SIDE

RIGHT SIDE

FRONT

Combustion Air Inlet
Condensate Drain
(Downflow)

Combustion Air Inlet

Gas Pipe
Entry

Vent Outlet

Gas Pipe
Entry

Electrical
Entry

Condensate Drain
(Downflow)

Electrical
Entry

Condensate
Drain

33

Thermostat
Wiring

Vent Outlet

Condensate
Drain

23”

Thermostat
Wiring

Optional Return Air
Cutout (Either side)

14”
1”

28.5”
29.5”

A

1.5”

.56”
23.8”

3”
Vent
Outlet

Combustion
Air Inlet

B

.56”

.56”

B
C

24.25”

20”

RETURN END

SUPPLY END

Cabinet & Duct Dimensions
Model

Nominal
3/min)

CFM (m

TM9Y040A10MP11
TM9Y060B12MP11
TM9Y080B12MP11
TM9Y080C16MP11
TM9Y100C16MP11
TM9Y100C20MP11
TM9Y120D20MP11

1000
1200
1200
1600
1600
2000
2000

A
B
B
C
C
C
D

Approximate
Operating Weights

Cabinet Dimensions (Inches)

Cabinet
Size

A

B

C

Lbs

14-1/2
17-1/2
17-1/2
21
21
21
24-1/2

13-3/8
16-3/8
16-3/8
19-7/8
19-7/8
19-7/8
23-3/8

11-3/4
13-1/4
14-3/4
16-1/2
18-1/4
18-1/4
21-3/4

113
119
123
130
136
143
154

Ratings & Physical / Electrical Data
Model

Input
High/Low

TM9Y040A10MP11
TM9Y060B12MP11
TM9Y080B12MP11
TM9Y080C16MP11
TM9Y100C16MP11
TM9Y100C20MP11
TM9Y120D20MP11
Model

Max. Outlet
Air Temp.

Blower

°F

HP

190
190
190
190
190
190
190

1/2
1/2
1/2
1/2
1/2
3/4
3/4

TM9Y040A10MP11
TM9Y060B12MP11
TM9Y080B12MP11
TM9Y080C16MP11
TM9Y100C16MP11
TM9Y100C20MP11
TM9Y120D20MP11

Output
High/Low

Total
Unit

MBH

MBH

Amps

%

°F

°F

40/26
60/39
80/52
80/52
100/65
100/65
120/78

38/25
58/37
77/50
77/50
96/62
96/62
115/75

9.5
9.5
9.5
9.5
9.5
10.9
10.9

96
95.5
96
96
96
96
96

25-55
35-65
45-75
40-70
50-80
45-75
50-80

25-55
35-65
35-65
25-55
30-60
30-60
45-75

Amps

In.

Max.
Over-current
Protect

Min. Wire Size
(awg) @ 75 ft.
One Way

6.8
6.8
6.8
6.8
6.8
8.4
8.4

11 X 8
11 x 8
11 x 8
11 x 10
11 x 10
11 x 11
11 x 11

15
15
15
15
15
15
15

14
14
14
14
14
14
14

AFUE

Blower Size

High Fire
Air Temp. Rise

Low Fire
Air Temp. Rise

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

5129599-YTG-A-0815

FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.

NOTICE
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a
20x25 filter.
Recommended Filter Sizes (High velocity 600 FPM)
CFM

Cabinet
Size

Side
(in)

Bottom
(in)

1000

A

16 x 25

14 x 25

1200

B

16 x 25

16 x 25

1600

C

16 x 25

20 x 25

2000

C

(2) 16 x 25

20 x 25

2000

D

(2) 16 x 25

22 x 25

1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.

Unit Clearances to Combustibles
Application

Upflow

Downflow

Horizontal

Top

1"

0"

0"

Vent

0"

0"

0"

Rear

0"

0"

0"

Side

0"

0"

1"

Front*

0"

0"

Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2”
plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts
(P/N S1-02630228000).
S1-1NK0301
Side Return Filter Racks S1-1SR0200 - All Models
S1-1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential
overheating situations.tible floor base kit provides access for
combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
S1-1CB0524 - For 24-1/2” cabinets
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
S1-1PS3308 - All Models
Thermostats - Compatible thermostat controls are available
through accessory sourcing.
EXTERNAL STATIC PRESSURE SETUP
Supply Duct

0"
1

Combustible

Floor

Combustible

Combustible

Closet

Yes

Yes

Yes

Line Contact

No

No

Yes

1. For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service
access.
All furnaces approved for alcove and attic installation.

ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas (N) units for propane (LP)
operation.
S1-1NP0347 - All Models
Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through
single common hole. Eliminates unsightly elbows for a cleaner
installation.
S1-1CT0302 (2") & S1-1CT0302-636 (2")
S1-1CT0303 (3") & S1-1CT0303-636 (3")
Sidewall Vent Termination Kit - For use on sidewall, two-pipe
installations only. Provide a more attractive termination for locations where the terminal is visible on the side of the home.
S1-1HT0901 (3")
S1-1HT0902 (2")

Johnson Controls Unitary Products

Return
Duct

Set appropriate airflow per temperature rise for gas heating. Set
appropriate airflow per “Blower Performance Table” for cooling/
heat pump heating operating based on outdoor unit size.
To measure external static pressure:
•
Measure the supply air static pressure
•
Record this positive number
•
Measure the return air static pressure
•
Record this negative number
•
Treat the negative number as a positive and add the two
numbers together
•
This is total system static
3

Blower Performance CFM - Any Position (without filter)
Bottom Airflow Data (SCFM)
Models

Ext. Static Pressure (in. H2O)

Speed
0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

High

1290

1260

1220

1160

1100

1040

960

840

750

660

Medium High

1170

1140

1110

1070

1040

990

930

820

730

650

Medium

990

980

940

900

860

830

790

730

680

630

Medium Low

900

880

850

810

770

730

670

630

600

560

Low

730

710

690

650

620

590

540

510

480

450

High

1402

1374

1354

1328

1299

1262

1222

1167

1107

1036

40A

Medium High

1252

1233

1203

1182

1150

1125

1095

1064

1031

980

Medium

1076

1059

1029

1007

973

946

908

883

843

800

Medium Low

988

967

936

903

875

838

806

765

737

685

Low

798

769

727

695

650

619

574

517

485

443

High

1445

1423

1397

1365

1339

1311

1283

1250

1204

1140

60B

Medium High

1282

1266

1232

1211

1182

1157

1128

1097

1069

1013

Medium

1098

1084

1059

1027

998

967

939

910

879

822

Medium Low

1012

993

953

930

894

851

828

773

752

692

Low

865

810

763

730

689

628

594

520

496

448

High

1713

1682

1643

1600

1558

1519

1480

1436

1385

1333

80B

Medium High

1554

1519

1485

1439

1404

1368

1327

1280

1176

1130

Medium

1380

1351

1302

1263

1224

1171

1128

1085

1030

943

Medium Low

1177

1142

1083

1050

988

922

890

819

798

687

Low

951

841

650

588

457

418

355

227

203

N/A

80C

High

1734

1694

1650

1611

1570

1536

1485

1438

1392

1335

Medium High

1568

1537

1492

1453

1414

1373

1327

1279

1230

1118

Medium

1420

1380

1332

1294

1249

1196

1152

1100

981

938

Medium

1218

1169

1124

1067

1015

965

894

845

754

679

Low

979

846

647

580

464

427

345

220

195

N/A

100C

High

2143

2102

2065

2028

1989

1944

1892

1825

1733

1625

Medium High

1788

1749

1718

1672

1629

1587

1541

1500

1447

1355

Medium

1575

1539

1500

1456

1410

1363

1305

1246

1095

1030

Medium Low

1372

1325

1276

1225

1170

1111

1044

972

884

812

Low

1031

921

810

728

660

615

518

474

391

355

High

2214

2173

2132

2086

2036

1994

1952

1907

1849

1777

100C

Medium High

1841

1799

1749

1699

1659

1611

1567

1520

1471

1372

Medium

1605

1562

1514

1470

1416

1361

1310

1180

1119

1045

Medium Low

1405

1362

1303

1244

1189

1125

1054

986

876

826

Low

1135

1020

844

758

671

557

511

464

387

N/A

120D

NOTES:

1. Airflow expressed in standard cubic feet per minute (SCFM).
2. Motor voltage at 115 V.

Subject to change without notice. Published in U.S.A.
Copyright © 2015 by Johnson Controls, Inc. All rights reserved.

York International Corp.
5005 York Drive
Norman, OK 73069

5129599-YTG-A-0815
Supersedes: Nothing



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : csardom
Create Date                     : 2015:08:10 09:19:12-05:00
Modify Date                     : 2015:08:19 14:31:14-05:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:08:19 14:31:14-05:00
Format                          : application/pdf
Title                           : 5129599-YTG-A-0815.fm
Creator                         : csardom
Producer                        : Acrobat Distiller 15.0 (Windows)
Document ID                     : uuid:3c033b40-6e0a-4073-b8bf-67036805a83d
Instance ID                     : uuid:60485f2a-589e-4650-9ef6-460757b99d98
Page Layout                     : OneColumn
Page Mode                       : UseThumbs
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu