York Tm9Y Technical Guide 5129599 YTG A 0815
2015-09-09
: York Tm9Y-Technical-Guide york-tm9y-technical-guide-811963 york pdf
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
5129599-YTG-A-0815 DESCRIPTION TECHNICAL GUIDE 96% AFUE TWO STAGE STANDARD ECM RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TM9Y These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized steel tubular primary heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation. These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping. FEATURES NATURAL GAS 40 - 120 MBH INPUT • • • • • • • • • • • • • • Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ahridirectory.org WARRANTY SUMMARY A 20-year limited warranty on heat exchangers in residential applications. A 10-year warranty on the heat exchanger in commercial applications. Standard 5-year limited Parts warranty. Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. • • • • • • • • • • • Two stage heating operation includes two stage gas valve, two stage inducer operation and constant torque standard ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat. Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. Compact, easy to install, ideal height 33" tall cabinet. Standard ECM constant torque drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance. Easy access to controls to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit current draw requirement for easy replacement application. All models are convertible to use propane (LP) gas. Electronic Hot Surface Ignition saves fuel use with increased dependability and reliability. 100% shut off main gas valve for extra safety. 24V, 40 VA control transformer and integrated furnace control supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency. Solid removable bottom panel allows easy conversion. Airflow leakage less than 1% of nominal airflow for duct blaster conditions. No knockouts to deal with, making installation easier. Movable duct connector flanges for application flexibility. Quiet inducer operation, burner, and blower operation. Inducer rotates for easy conversion of venting options. Fully supported blower assembly for easy access and removal of blower. External air filters used for maximum flexibility in meeting customers IAQ needs. Insulated blower compartment for thermal and acoustic performance. 1/4 turn knobs provided for easy independent door removal. Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems. Protection included from air intake, exhaust vent or condensate blockage. Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air. See Limited Warranty certificate in Users Information Manual for details. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5129599-YTG-A-0815 LEFT SIDE RIGHT SIDE FRONT Combustion Air Inlet Condensate Drain (Downflow) Combustion Air Inlet Gas Pipe Entry Vent Outlet Gas Pipe Entry Electrical Entry Condensate Drain (Downflow) Electrical Entry Condensate Drain 33 Thermostat Wiring Vent Outlet Condensate Drain 23” Thermostat Wiring Optional Return Air Cutout (Either side) 14” 1” 28.5” 29.5” A 1.5” .56” 23.8” 3” Vent Outlet Combustion Air Inlet B .56” .56” B C 24.25” 20” RETURN END SUPPLY END Cabinet & Duct Dimensions Model Nominal 3/min) CFM (m TM9Y040A10MP11 TM9Y060B12MP11 TM9Y080B12MP11 TM9Y080C16MP11 TM9Y100C16MP11 TM9Y100C20MP11 TM9Y120D20MP11 1000 1200 1200 1600 1600 2000 2000 A B B C C C D Approximate Operating Weights Cabinet Dimensions (Inches) Cabinet Size A B C Lbs 14-1/2 17-1/2 17-1/2 21 21 21 24-1/2 13-3/8 16-3/8 16-3/8 19-7/8 19-7/8 19-7/8 23-3/8 11-3/4 13-1/4 14-3/4 16-1/2 18-1/4 18-1/4 21-3/4 113 119 123 130 136 143 154 Ratings & Physical / Electrical Data Model Input High/Low TM9Y040A10MP11 TM9Y060B12MP11 TM9Y080B12MP11 TM9Y080C16MP11 TM9Y100C16MP11 TM9Y100C20MP11 TM9Y120D20MP11 Model Max. Outlet Air Temp. Blower °F HP 190 190 190 190 190 190 190 1/2 1/2 1/2 1/2 1/2 3/4 3/4 TM9Y040A10MP11 TM9Y060B12MP11 TM9Y080B12MP11 TM9Y080C16MP11 TM9Y100C16MP11 TM9Y100C20MP11 TM9Y120D20MP11 Output High/Low Total Unit MBH MBH Amps % °F °F 40/26 60/39 80/52 80/52 100/65 100/65 120/78 38/25 58/37 77/50 77/50 96/62 96/62 115/75 9.5 9.5 9.5 9.5 9.5 10.9 10.9 96 95.5 96 96 96 96 96 25-55 35-65 45-75 40-70 50-80 45-75 50-80 25-55 35-65 35-65 25-55 30-60 30-60 45-75 Amps In. Max. Over-current Protect Min. Wire Size (awg) @ 75 ft. One Way 6.8 6.8 6.8 6.8 6.8 8.4 8.4 11 X 8 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11 11 x 11 15 15 15 15 15 15 15 14 14 14 14 14 14 14 AFUE Blower Size High Fire Air Temp. Rise Low Fire Air Temp. Rise Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 5129599-YTG-A-0815 FILTER PERFORMANCE The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT filters. All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace. NOTICE Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a 20x25 filter. Recommended Filter Sizes (High velocity 600 FPM) CFM Cabinet Size Side (in) Bottom (in) 1000 A 16 x 25 14 x 25 1200 B 16 x 25 16 x 25 1600 C 16 x 25 20 x 25 2000 C (2) 16 x 25 20 x 25 2000 D (2) 16 x 25 22 x 25 1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters. 2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter. Unit Clearances to Combustibles Application Upflow Downflow Horizontal Top 1" 0" 0" Vent 0" 0" 0" Rear 0" 0" 0" Side 0" 0" 1" Front* 0" 0" Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2” plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (P/N S1-02630228000). S1-1NK0301 Side Return Filter Racks S1-1SR0200 - All Models S1-1SR0402 - All Models Bottom Return Filter Racks - 1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet. S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets S1-1BR0521 or 1BR0621 - For 21” cabinets S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations.tible floor base kit provides access for combustible airflow. S1-1CB0514 - For 14-1/2” cabinets S1-1CB0517 - For 17-1/2” cabinets S1-1CB0521 - For 21” cabinets S1-1CB0524 - For 24-1/2” cabinets High Altitude Pressure Switches - For installation where the altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits below. S1-1PS3308 - All Models Thermostats - Compatible thermostat controls are available through accessory sourcing. EXTERNAL STATIC PRESSURE SETUP Supply Duct 0" 1 Combustible Floor Combustible Combustible Closet Yes Yes Yes Line Contact No No Yes 1. For combustible floors only when used with special sub-base. * - 24" clearance in front and 18" on side recommended for service access. All furnaces approved for alcove and attic installation. ACCESSORIES Propane (LP) Conversion Kit - This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. S1-1NP0347 - All Models Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. Eliminates unsightly elbows for a cleaner installation. S1-1CT0302 (2") & S1-1CT0302-636 (2") S1-1CT0303 (3") & S1-1CT0303-636 (3") Sidewall Vent Termination Kit - For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visible on the side of the home. S1-1HT0901 (3") S1-1HT0902 (2") Johnson Controls Unitary Products Return Duct Set appropriate airflow per temperature rise for gas heating. Set appropriate airflow per “Blower Performance Table” for cooling/ heat pump heating operating based on outdoor unit size. To measure external static pressure: • Measure the supply air static pressure • Record this positive number • Measure the return air static pressure • Record this negative number • Treat the negative number as a positive and add the two numbers together • This is total system static 3 Blower Performance CFM - Any Position (without filter) Bottom Airflow Data (SCFM) Models Ext. Static Pressure (in. H2O) Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 High 1290 1260 1220 1160 1100 1040 960 840 750 660 Medium High 1170 1140 1110 1070 1040 990 930 820 730 650 Medium 990 980 940 900 860 830 790 730 680 630 Medium Low 900 880 850 810 770 730 670 630 600 560 Low 730 710 690 650 620 590 540 510 480 450 High 1402 1374 1354 1328 1299 1262 1222 1167 1107 1036 40A Medium High 1252 1233 1203 1182 1150 1125 1095 1064 1031 980 Medium 1076 1059 1029 1007 973 946 908 883 843 800 Medium Low 988 967 936 903 875 838 806 765 737 685 Low 798 769 727 695 650 619 574 517 485 443 High 1445 1423 1397 1365 1339 1311 1283 1250 1204 1140 60B Medium High 1282 1266 1232 1211 1182 1157 1128 1097 1069 1013 Medium 1098 1084 1059 1027 998 967 939 910 879 822 Medium Low 1012 993 953 930 894 851 828 773 752 692 Low 865 810 763 730 689 628 594 520 496 448 High 1713 1682 1643 1600 1558 1519 1480 1436 1385 1333 80B Medium High 1554 1519 1485 1439 1404 1368 1327 1280 1176 1130 Medium 1380 1351 1302 1263 1224 1171 1128 1085 1030 943 Medium Low 1177 1142 1083 1050 988 922 890 819 798 687 Low 951 841 650 588 457 418 355 227 203 N/A 80C High 1734 1694 1650 1611 1570 1536 1485 1438 1392 1335 Medium High 1568 1537 1492 1453 1414 1373 1327 1279 1230 1118 Medium 1420 1380 1332 1294 1249 1196 1152 1100 981 938 Medium 1218 1169 1124 1067 1015 965 894 845 754 679 Low 979 846 647 580 464 427 345 220 195 N/A 100C High 2143 2102 2065 2028 1989 1944 1892 1825 1733 1625 Medium High 1788 1749 1718 1672 1629 1587 1541 1500 1447 1355 Medium 1575 1539 1500 1456 1410 1363 1305 1246 1095 1030 Medium Low 1372 1325 1276 1225 1170 1111 1044 972 884 812 Low 1031 921 810 728 660 615 518 474 391 355 High 2214 2173 2132 2086 2036 1994 1952 1907 1849 1777 100C Medium High 1841 1799 1749 1699 1659 1611 1567 1520 1471 1372 Medium 1605 1562 1514 1470 1416 1361 1310 1180 1119 1045 Medium Low 1405 1362 1303 1244 1189 1125 1054 986 876 826 Low 1135 1020 844 758 671 557 511 464 387 N/A 120D NOTES: 1. Airflow expressed in standard cubic feet per minute (SCFM). 2. Motor voltage at 115 V. Subject to change without notice. Published in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved. York International Corp. 5005 York Drive Norman, OK 73069 5129599-YTG-A-0815 Supersedes: Nothing
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : csardom Create Date : 2015:08:10 09:19:12-05:00 Modify Date : 2015:08:19 14:31:14-05:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:08:19 14:31:14-05:00 Format : application/pdf Title : 5129599-YTG-A-0815.fm Creator : csardom Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:3c033b40-6e0a-4073-b8bf-67036805a83d Instance ID : uuid:60485f2a-589e-4650-9ef6-460757b99d98 Page Layout : OneColumn Page Mode : UseThumbs Page Count : 4EXIF Metadata provided by EXIF.tools