York Ycal0041 Users Manual Air Cooled Scroll Chiller (Style D) YCAL0041–YCAL0065 (47–60 TON) R 22 (50 & 60HZ)
YCAL0041 to the manual f2e4a920-9955-493f-bd43-b1337a709bdc
2015-02-02
: York Ycal0041-Users-Manual york-ycal0041-users-manual-455205 york pdf
Open the PDF directly: View PDF .
Page Count: 80
Download | |
Open PDF In Browser | View PDF |
FORM 150.64-EG1 (505) AIR-COOLED SCROLL CHILLERS STYLE D YCAL0041 – YCAL0065 50 AND 60HZ 47 – 60 TON 165 – 210 KW R-22 Table of Contents FORM 150.64-EG1 (405) ....................................................................................................................................................................................... 1 Introduction........................................................................................................................................................................................................... 3 Specification ......................................................................................................................................................................................................... 4 Options and Accessories .................................................................................................................................................................................... 7 Selection Data ......................................................................................................................................................................................................11 Design Parameters ............................................................................................................................................................................................. 13 Water Pressure Drop .......................................................................................................................................................................................... 14 Ratings - R-22 (60Hz - English Units) ............................................................................................................................................................... 16 Ratings - R-22 (60Hz - English Units) - Cont. ................................................................................................................................................... 18 Ratings - R-22 (60Hz - SI Units) ......................................................................................................................................................................... 20 Ratings - R-22 (50Hz - English Units) ............................................................................................................................................................... 22 Ratings - R-22 (50Hz - English Units) - Cont. ................................................................................................................................................... 24 Ratings - R-22 (50Hz - SI Units) ......................................................................................................................................................................... 26 Part Load Ratings - R-22 (English Units) ......................................................................................................................................................... 28 Part Load Ratings - R-22 (SI) ............................................................................................................................................................................. 29 Physical Data ..................................................................................................................................................................................................... 30 Sound Data.......................................................................................................................................................................................................... 32 Dimensions - YCAL0041 (English) .................................................................................................................................................................... 34 Dimensions - YCAL0045 (English) .................................................................................................................................................................... 36 Dimensions - YCAL0051 (English) .................................................................................................................................................................... 38 Dimensions - YCAL0055EC - (English)............................................................................................................................................................. 40 Dimensions - YCAL0061 (English) .................................................................................................................................................................... 42 Dimensions - YCAL0065 (English) .................................................................................................................................................................... 44 Dimensions - YCAL0041 (SI) ............................................................................................................................................................................. 46 Dimensions - YCAL0045 (SI) ............................................................................................................................................................................. 48 Dimensions - YCAL0051 (SI) ............................................................................................................................................................................. 50 Dimensions -YCAL0055 (SI) .............................................................................................................................................................................. 52 Dimensions - YCAL0061 (SI) ............................................................................................................................................................................. 54 Dimensions - YCAL0065 (SI) ............................................................................................................................................................................. 56 Isolator Selections ............................................................................................................................................................................................. 58 Isolator Details (cont'd) ...................................................................................................................................................................................... 60 Electrical Data ..................................................................................................................................................................................................... 62 Electrical Data - 60Hz ......................................................................................................................................................................................... 64 Electrical Data - 50Hz ......................................................................................................................................................................................... 66 Power Wiring....................................................................................................................................................................................................... 68 Control Wiring..................................................................................................................................................................................................... 71 Application Data ................................................................................................................................................................................................. 72 Guide Specifications .......................................................................................................................................................................................... 74 ������� ������ � ���� ���������������������� ������ ������ � ����������� ���������� ��������������� ������������ ���� ����� �� ��������������� ������� ���� ��� �������� ��� �������� ��� �������� ��� �������� ��� �������� ����������� ������� �������� �� ���� ������������������� ���� 2 YORK INTERNATIONAL Introduction FORM 150.64-EG1 YORK Air-Cooled Scroll Chillers provide chilled water for all air conditioning applications using central station air handling or terminal units. They are completely self-contained and are designed for outdoor (roof or ground level) installation. Each unit includes hermetic scroll compressors, a liquid cooler, air cooled condenser, and a weather resistant microprocessor control center, all mounted on a pressed steel base. YORK INTERNATIONAL 3 Specification GENERAL The 47 - 60 Ton (165 - 210 kW) YCAL models are shipped complete from the factory ready for installation and use. The unit is pressure-tested, evacuated, and fully charged with Refrigerant-22 (HCFC-22) and includes an initial oil charge. After assembly, a complete operational test is performed with water flowing through the cooler to assure that the refrigeration circuit operates correctly. The unit structure is heavy-gauge, galvanized steel. This galvanized steel is coated with baked-on powder paint, which, when subjected to ASTM B117 1000 hour, salt spray testing, yields a minimum ASTM 1654 rating of “6”. Corrosion resistant wire mesh panels are added to protect the condenser coil from incidental damage and restrict unauthorized access to internal components. Units are designed in accordance with NFPA 70 (National Electric Code), ASHRAE/ANSI 15 Safety code for mechanical refrigeration, ASME, Listed and labeled with Intertek Testing Services (ETL) and rated in accordance with ARI Standard 550/590-2003. COMPRESSORS The chiller has suction-gas cooled, hermetic, scroll compressors. The YCAL compressors incorporate a compliant scroll design in both the axial and radial direction. All rotating parts are statically and dynamically balanced. A large internal volume and oil reservoir provides greater liquid tolerance. Compressor crankcase heaters are also included for extra protection against liquid migration. COOLER The cooler is equipped with a heater controlled by a separate thermostat. The heater provides freeze protec- 4 tion for the cooler down to -20°F (-29°C) ambient. The cooler is covered with 3/4” (19mm) flexible, closed-cell, foam insulation (K~0.25). Brazed plate heat exchangers shall be UL (Underwriters Laboratories) listed. Installing contractor must include accommodations in the chilled water piping to allow proper drainage and venting of the heat exchanger. Water inlet and outlet connections are grooved for compatibility with factory supplied victaulic connections. A strainer with a mesh size between .5 and 1.5 mm (40 mesh) is recommended upstream of the heat exchanger to prevent clogging. CONDENSER Coils – Fin and tube condenser coils of seamless, internally-enhanced, high-condensing-coefficient, corrosion resistant copper tubes are arranged in staggered rows, mechanically expanded into aluminum fins. Integral subcooling is included. The design working pressure of the coil is 450 PSIG (31 bar). Low Sound Fans – The condenser fans are composed of corrosion resistant aluminum hub and glass-fiberreinforced composite blades molded into a low noise airfoil section. They are designed for maximum efficiency and are statically and dynamically balanced for vibration free operation. They are directly driven by independent motors, and positioned for vertical air discharge. All blades are statically and dynamically balanced for vibration-free operation. The fan guards are constructed of heavygauge, rust-resistant, PVCcoated steel wire. Motors – The fan motors are Totally Enclosed Air-Over, squirrel-cage type, current protected. They feature ball bearings that are double-sealed and permanently lubricated. YORK INTERNATIONAL FORM 150.64-EG1 MILLENNIUM CONTROL CENTER All controls are contained in a NEMA 3R/12 (and equivalent to IP55*) cabinet with hinged outer door and includes: Liquid Crystal Display with Light Emitting Diode backlighting for outdoor viewing: Two display lines Twenty characters per line Color coded 12-button non-tactile keypad with sections for: DISPLAY/PRINT of typical information: Chilled liquid temperatures Ambient temperature System pressures (each circuit) Operating hours and starts (each compressor) Print calls up to the liquid crystal display: Operating data for the systems History of fault shutdown data for up to the last six fault shutdown conditions An RS-232 port, in conjunction with this press-to-print button, is provided to permit the capability of hard copy print-outs via a separate printer (by others). ENTRY section to: ENTER setpoints or modify system values SETPOINTS updating can be performed to: Chilled liquid temperature setpoint and range Remote reset temperature range Set daily schedule/holiday for start/stop Manual override for servicing Low and high ambient cutouts Number of compressors Low liquid temperature cutout Low suction pressure cutout High discharge pressure cutout Anti-recycle timer (compressor start cycle time) Anti-coincident timer (delay compressor starts) UNIT section to: Set time Set unit options * UNIT ON/OFF switch The microprocessor control center is capable of displaying the following: • • • • • • • • • • • • • • • • • • • • • • • • • Return and leaving liquid temperature Low leaving liquid temperature cutout setting Low ambient temperature cutout setting Outdoor air temperature English or Metric data Suction pressure cutout setting Each system suction pressure Discharge pressure (optional) Liquid Temperature Reset via a YORK ISN DDC or Building Automation System (by others) via: - a pulse width modulated (PWM) input as standard - a 4-20 milliamp or 0 -10 VDC input, or contact closure with the optional B.A.S. interface option Anti-recycle timer status for each system Anti-coincident system start timer condition Compressor run status No cooling load condition Day, date and time Daily start/stop times Holiday status Automatic or manual system lead/lag control Lead system definition Compressor starts & operating hours (each compressor) Status of hot gas valves, evaporator heater and fan operation Run permissive status Number of compressors running Liquid solenoid valve status Load & unload timer status Water pump status Intensity of Protection European Standard YORK INTERNATIONAL 5 Provisions are included for: pumpdown at shutdown; optional remote chilled water temperature reset and two steps of demand load limiting from an external building automation system. Unit alarm contacts are standard. The operating program is stored in non-volatile memory (EPROM) to eliminate chiller failure due to AC powered failure/battery discharge. Programmed setpoints are retained in lithium battery-backed RTC memory for 5 years minimum. POWER PANEL Each panel contains: • Compressor power terminals • Compressor motor starting contactors per l.E.C.** • Control power terminals to accept incoming for 115-1-60 control power • Fan contactors & overload current protection The power wiring is routed through liquid-tight conduit to the compressors and fans. ** International Electrotechnical Commission 6 YORK INTERNATIONAL Options and Accessories POWER OPTIONS: COMPRESSOR POWER CONNECTIONS – Singlepoint (YCAL0041-0065) terminal block connection(s) are provided as standard. The following power connections are available as options. (See electrical data for specific voltage and options availability.) (Factory-Mounted.) SINGLE-POINT SUPPLY TERMINAL BLOCK – (standard on YCAL0041 - 0065 models). Includes enclosure, terminal-block and interconnecting wiring to the compressors. Separate external protection must be supplied, by others, in the incoming compressor-power wiring. (Do not include this option if either the SinglePoint NonFused Disconnect Switch or Single-Point Circuit Breaker options have been included.) SINGLE-POINT NON-FUSED DISCONNECT SWITCH – Unit-mounted disconnect switch with external, lockable handle (in compliance with Article 440-14 of N.E.C.), can be supplied to isolate the unit power voltage for servicing. Separate external fusing must be supplied, by others in the power wiring, which must comply with the National Electrical Code and/or local codes. SINGLE-POINT CIRCUIT BREAKER – A unit mounted circuit breaker with external, lockable handle (in compliance with N.E.C. Article 440-14), can be supplied to isolate the power voltage for servicing. (This option includes the Single-Point Power connection.) CONTROL TRANSFORMER – Converts unit power voltage to 115-1-60 (0.5 or 1.0 KVA capacity). Factory mounting includes primary and secondary wiring between the transformer and the control panel. (Factory-Mounted.) POWER FACTOR CORRECTION CAPACITORS – Will correct unit compressor power factors to a 0.90-0.95. (Factory-Mounted.) CONTROL OPTIONS: AMBIENT KIT (LOW) – Units will operate to 25°F (-4°C). This accessory includes all necessary components to permit chiller operation to 0°F (-18°C). (This option includes the Discharge Pressure Transducer / Readout Capability option.) For proper head pressure control in applications below 25°F (-4°C), where wind gusts may exceed five mph, it is recommended that Optional Condenser Louvered Enclosure Panels also be included. (Factory-Mounted.) AMBIENT KIT (HIGH) – Required if units are to operate when the ambient temperature is above 115°F (46°C). Includes discharge pressure transducers. (This option YORK INTERNATIONAL FORM 150.64-EG1 includes the Discharge Pressure Transducer / ReadoutCapability option.) (Field-Mounted.) BUILDING AUTOMATION SYSTEM INTERFACE – The factory addition of a Printed Circuit Board to accept a 4-20 milliamp, 0-10VDC or contact closure input to reset the leaving chiller liquid temperature from a Building Automation System. (Only one of following options can be offered on a unit at a time: BAS, Remote Control Panel or Multi-unit Sequence Control.) (Factory-Mounted.) (The standard unit capabilities include remote startstop, remote water temperature reset via a PWM input signal or up to two steps of demand (load) limiting depending on model.) (The standard control panel can be directly connected to a YORK Building Automated System via the standard onboard RS485 communication port.) LANGUAGE LCD AND KEYPAD DISPLAY – Spanish, French, and German unit LCD controls and keypad display available. Standard language is English. DISCHARGE PRESSURE TRANSDUCERS AND READOUT CAPABILITY – The addition of pressure transducers allows models to sense and display discharge pressure. This is recommended for brine chilling applications. (This option is included with either the low or high ambient kits.) (Factory-Mounted.) • Suction Pressure Transducers: Permits unit to sense and display suction pressure. This capability is standard on YCAL0041-0065 models. MOTOR CURRENT MODULE – Capable of monitoring compressor motor current. Provides extra protection against compressor reverse rotation, phase-loss and phase imbalance. Option consists of one module per electrical system. (Factory-Mounted.) OPTIVIEW REMOTE CONTROL PANEL - Graphical interface panel to remotely control and monitor up to 8 different units. (Refer to form 201.18-SG4 for detailed information) MULTI-UNIT SEQUENCING – A separate Sequencing Control Center is provided to handle sequencing control of up to eight chillers in parallel based on mixed liquid temperature (interconnecting wiring by others). (Only one of following options can be offered on a unit at a time: BAS, Remote Control Panel or Multi-unit Sequence Control.) (Factory-Mounted.) COMPRESSOR, PIPING, EVAPORATOR OPTIONS: LOW TEMPERATURE BRINE – Required for brine 7 chilling below 30°F (-1°C) leaving brine temperature for YCAL0041 - 0065 models. Option includes resized thermal expansion valve. (Factory-Mounted) CHICAGO CODE RELIEF VALVES – Unit will be provided with relief valves to meet Chicago code requirements. (Factory-Mounted) SERVICE ISOLATION VALVE – Service suction and discharge (ball type) isolation valves are added to unit per system. This option also includes a system high pressure relief valve in compliance with ASHRAE 15. (Factory-Mounted) HOT GAS BY-PASS – Permits continuous, stable operation at capacities below the minimum step of compressor unloading to as low as 5% capacity (depending on both the unit and operating conditions) by introducing an artificial load on the cooler. Hot gas by-pass is installed on only refrigerant system #1 on two-circuited units. (Factory-Mounted) DX COOLER 300 PSIG (21 bar) DWP WATERSIDE – The waterside will be of 300 PSIG (21 bar) instead of the standard 150 PSIG DWP. 300 PSIG R.F. flanges are included on the DX cooler nozzles. (Factory-Mounted.) The companion flanges will be field-supplied by others. FLANGES (VICTAULIC TYPE) – Consists of two (2) Flange adapters for grooved end pipe (standard 150 psi [10.5 bar] cooler). FLOW SWITCH – The flow switch or its equivalent must be furnished with each unit. 150 PSIG (10.5 bar) DWP – For standard units. Johnson Controls model F61MG-1C Vapor-proof SPDT, NEMA 4X switch (150 PSIG [10.5 bar] DWP), -20°F to 250°F (-29°C to 121°C), with 1” NPT connection for upright mounting in horizontal pipe. (Field-Mounted.) 300 psig (21 bar) DWP – For units with optional 300 PSIG (21 bar) DX cooler. McDonnell & Miller model FS74W Vapor-proof SPDT, NEMA 4X switch (300 PSIG (21 bar) DWP), -20°F to 300°F (-29°C to 149°C), with 1¼ inch MPT connection for upright mounting in horizontal pipe. (Field-Mounted.) DIFFERENTIAL PRESSURE SWITCH – Alternative to an above mentioned flow switch. Pretempco model DPS300AP40PF-82582-5 (300 psi max. working pressure), SPDT 5 amp 125/250VAC switch, Range 0 - 40 PSID, deadband 0.5 - 0.8 psi, with 1/4” NPTE Pressure Connections. 8 REMOTE DX COOLER – A split system arrangement with the cooler, leaving & return water sensors, liquid line solenoid valves, filter driers, sightglasses & TXVs shipped loose for field connection to the air-cooled condensing section. The DX cooler and outdoor section will have a nitrogen holding charge. Interconnecting rigid piping, wiring and refrigerant are by others. Includes YORK Service startup. See Form 150.62-NM1.1 (200) for other application information. (This option includes the Crankcase Heater option.)(Field-Mounted.) CONDENSER AND CABINET OPTIONS: Condenser coil protection against corrosive environments is available by choosing any of the following options. For additional application recommendations, refer to FORM 150.12-ES1. (Factory-Mounted.) PRE-COATED FIN CONDENSER COILS – The unit's coils are constructed with black epoxy coated aluminum fins. This can provide corrosion resistance comparable to copper-fin coils in typical seashore locations. Either these or the post-coated coils (below), are recommended for units being installed at the seashore or where salt spray may hit the unit. POST-COATED DIPPED CONDENSER COILS – The unit's coils are constructed with dipped-cured condenser coils. This is another choice for seashore and other corrosive applications (with the exception of strong alkalies, oxidizers and wet bromine, chlorine and fluorine in concentrations greater than 100 ppm). COPPER FIN CONDENSER COILS – The unit's coils are constructed with copper fins. (This is not recommended for units in areas where they may be exposed to acid rain.) ENCLOSURE PANELS (UNIT) – Tamperproof Enclosure Panels prevent unauthorized access to units. Enclosure Panels can provide an aesthetically pleasing alternative to expensive fencing. Additionally, for proper head pressure control, YORK recommends the use of : LOUVERED PANELS (Full Unit) – Louvered panels surround the front, back, and sides of the unit. They prevent unauthorized access and visually screen unit components. Unrestricted air flow is permitted through generously sized louvered openings. This option is applicable for any outdoor design ambient temperature up to 115°F (46°C). (Factory-Mounted.) SOUND ATTENUATION – One or both of the following sound attenuation options are recommended for YORK INTERNATIONAL FORM 150.64-EG1 residential or other similar sound-sensitive locations. Louvered Panels can be ordered for winter applications where wind gusts may exceed five miles per hour. The following types of enclosure options are available: COMPRESSOR ACOUSTIC SOUND BLANKET – Each compressor is individually enclosed by an acoustic sound blanket. The sound blankets are made with one layer of acoustical absorbent textile fiber of 5/8” (15mm) thickness; one layer of anti-vibrating heavy material thickness of 1/8” (3mm). Both are closed by two sheets YORK INTERNATIONAL of welded PVC, reinforced for temperature and UV resistance. (Factory-Mounted.) ULTRA QUIET FANS – Lower RPM, 8-pole fan motors are used with steeper-pitch fans. (Factory-Mounted.) VIBRATION ISOLATORS – Level adjusting, spring type 1” (25.4mm) or seismic deflection or neoprene pad isolators for mounting under unit base rails. (FieldMounted.) 9 This page intentionally left blank. 10 YORK INTERNATIONAL FORM 150.64-EG1 Selection Data GUIDE TO SELECTION Capacity ratings for YORK YCAL Packaged Air-Cooled Liquid Chillers, shown on pages 16 through 39 cover the majority of design applications for these units. For unusual applications or uses beyond the scope of this catalog, please consult your nearest YORK Office or representative. 6. Ethylene Glycol Correction Factors – The following factors are to be applied to the standard ratings for units cooling ethylene glycol. ETHYLENE GLYCOL % WEIGHT TONS COMPR KW GPM °F/TON PRESS DROP FREEZE PT 10 0.996 0.999 24.3 1.049 26.2 20 0.991 0.998 25.1 1.124 17.9 30 0.984 0.997 25.9 1.258 6.7 40 0.976 0.995 26.9 1.430 -8.1 50 0.968 0.994 28.0 1.650 -28.9 SELECTION RULES 1. Ratings – Ratings may be interpolated, but must not be extrapolated. The Ratings given on pages 16 through 39 and the DESIGN PARAMETERS given on page 11 indicate the limits of application for these chillers. 2. Cooler Water – Ratings are based upon 2.4 GPM per ton which is equal to a 10°F chilled water range and a 0.0001 fouling factor for the cooler at sea level. Tables on pages 16 through 39 give capacity, compressor kW required, cooler GPM and unit EER. 3. Condenser – Ratings are given in terms of air on condenser in degrees Fahrenheit. 4. Copper Fin Condenser Ratings – Since the thermal conductivity of copper is slightly higher than aluminum, apply the following corrections to the standard ratings. Tons x 0.97 and compressor kW x 0.99. 5. Performance Data Correction Factors – Ratings are based on 0.0001 cooler fouling factor, 10°F chilled water range and at sea level. For operation at different conditions, apply the appropriate correction factor from the following table. ALTITUDE SEA LEVEL 2000 FT. 4000 FT. 6000 FT. FOULING FACTOR 0.0001 TEMP COMPR TONS SPLIT kW 8 0.990 0.998 10 1.000 1.000 12 1.012 1.003 14 1.021 1.005 8 0.987 1.005 10 0.997 1.008 12 1.009 1.010 14 1.018 1.012 8 0.983 1.014 10 0.994 1.016 12 1.005 1.019 14 1.014 1.021 8 0.980 1.023 10 0.990 1.025 12 1.002 1.028 14 1.011 1.030 YORK INTERNATIONAL 0.00025 COMPR TONS kW 0.979 0.996 0.991 0.998 1.002 1.001 1.012 1.003 0.978 1.003 0.988 1.006 1.000 1.008 1.009 1.010 0.975 1.012 0.985 1.014 1.111 1.017 1.006 1.019 0.971 1.021 0.982 1.023 0.993 1.026 1.002 1.028 7. Propylene Glycol Correction Factors – The following factors are to be applied to the standard ratings for units cooling propylene glycol. PROPYLENE GLYCOL % WEIGHT TONS COMPR KW GPM °F/TON PRESS DROP FREEZE PT 10 0.995 0.999 24.0 1.014 26 20 0.984 0.997 24.3 1.104 19 30 0.973 0.994 24.9 1.234 9 40 0.960 0.992 25.6 1.399 -6 50 0.943 0.989 26.6 1.599 -28 METHOD OF SELECTION To select of YORK Packaged Air-Cooled Liquid Chiller, the following data must be known: 1. 2. 3. 4. Design Capacity in tons refrigeration (TR). Entering and Leaving Liquid Temperatures. Outside ambient air temperature in degrees F. GPM of chilled liquid. Determine capacity requirements from the following formula: GPM = TR x 24 RANGE (°F) EXAMPLE – WATER CHILLING 1. Given: Provide a capacity of 50 tons at 42 F leaving water at 10 F range. 0.0001FF, 85 F air on the condenser, at sea level and 60 Hz. 2. Find: Unit Size, Compressor KW Output 3. From the ratings on page 18. Select: YCAL0061 (English Units) 11 a. 56.1 Tons b. 55.9 Compressor KW c. 10.7 Unit EER 4. Calculate Compressor kW at 50 Tons: 50 x55.9kW = 49.8kW 56.1 5. Calculate GPM: kW = (50Tons ) × 24 GPM = = 120 GPM 10 ° FRange 6. From page ____, read 6 ft of water cooler pressure drop from GPM: 7. A YCAL0061 is suitable. EXAMPLE - BRINE CHILLING Example - Brine Chilling 1. Given: Provide a capacity of 34 tons cooling 30% by weight Ethylene Glycol from 50 F to 40 F, 0.00025FF, 95 F air on the condenser, 60 Hz and 4000 ft. altitude. 2. Determine: a. Unit Size b. KW Input c. Ethylene Glycol GPM d. Cooler Pressure Drop 3. See E.G. correction factors, for 30% by weight E.G. READ: 0.984 Tons Factor 0.997 Compr. KW factor 26.1 Gal,/ F/Tons Factor 4. See Performance Data Correction Factors for 0.00025 fouling factor and 4,000 ft. altitude. READ: 0.975 Tons factor 1.012 kW factor 5. From RATINGS on page 16. SELECT: YCAL0045 (English Units) 35.3 Tons 41.1 Compressor kW 6. Determine YCAL0045 brine cooling capacity and Compressor kW requirement from pg 14: a. TONS: = 35.3 x 0.984 x 0.975 = 33.87 b. Compr. KW = 41.1 x 0.997 x 1.012 = 41.77 12 7. Determine average full load Compressor kW at 34 tons 34tons x(41.77) = 41.93CompressorkW 33.87tons 8. Determine E.G. GPM: GPM = Tons × Gal .° F / min/ Tonfactor Range GPM = 34.0 × 26.1 = 88.7(GPM ) 10 9. Determine Cooler Pressure Drop: a. See E.G. correction factors for 30% by weight E.G. READ: 1.258 Pressure Drop factor b. See page 14 at 88.7 GPM for YCAL0045 READ: 6.5_Water H2O PD c. Cooler Pressure Drop = 6.5 x 1.258 or 8.17 A YCAL0045 is suitable. YORK INTERNATIONAL FORM 150.64-EG1 Design Parameters ENGLISH YCAL LEAVING WATER TEMPERATURE (°F) COOLER FLOW (GPM) AIR ON CONDENSER (°F) MIN MAX MIN MAX MIN MAX 0041 40 55 40 200 0 125 0045 40 55 40 200 0 125 0051 40 55 40 200 0 125 0055 40 55 60 300 0 125 0061 40 55 60 300 0 125 0065 40 55 60 300 0 125 SI UNITS YCAL LEAVING WATER TEMPERATURE (°DC) COOLER FLOW (L/S) AIR ON CONDENSER (°C) MIN MAX MIN MAX MIN MAX 0041 4.4 12.8 2.5 12.6 -17.7 51.7 0045 4.4 12.8 2.5 12.6 -17.7 51.7 0051 4.4 12.8 2.5 12.6 -17.7 51.7 0055 4.4 12.8 3.8 18.9 -17.7 51.7 0061 4.4 12.8 3.8 18.9 -17.7 51.7 0065 4.4 12.8 3.8 18.9 -17.7 51.7 NOTES: 1. For leaving brine temperature below 40°F (4.4°C), contact your nearest YORK Office for application requirements. 2. For leaving water temperature higher than 55°F (12.8°C), contact the nearest YORK Office for application guidelines. 3. The evaporator is protected against freezing to -20°F (-28.8°C) with an electric heater as standard. 4. For operation at temperatures below 25°F (-3.9°C), the optional Low Ambient Kit will need to be installed on the system (for YCAL0041-0065 models only). 5. For operation at temperatures above 115°F (46.1°C), the optional High Ambient Kit will need to be installed on the system. YORK INTERNATIONAL 13 Water Pressure Drop ENGLISH 100 A Press Drop, Ft H 2O B C D 10 1 10 100 1000 FLOW, GPM Note: Water Pressure Drop Curves may extend past the minimum and maximum water flow ranges. See page 13 for minimum and maximum flow points. 14 YORK INTERNATIONAL FORM 150.64-EG1 SI Press Drop, kPA 1000 A B 100 C D 10 1 1 10 FLOW, L/S 100 Note: Water Pressure Drop Curves may extend past the minimum and maximum water flow ranges. See page 13 for minimum and maximum flow points. YORK INTERNATIONAL 15 Ratings - R-22 (60Hz - English Units) MODEL: YCAL0041EC IPLV= 13.9 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW 40.0 35.8 30.3 12.0 35.1 32.0 11.2 34.4 33.8 10.5 33.7 42.0 37.0 30.6 12.3 36.2 32.2 11.5 35.5 34.0 10.8 34.8 44.0 38.1 30.8 12.6 37.4 32.5 11.8 36.7 34.3 11.0 45.0 38.7 31.0 12.7 38.0 32.6 11.9 37.2 34.4 46.0 39.3 31.1 12.9 38.6 32.8 12.1 37.8 34.5 48.0 40.6 31.4 13.2 39.8 33.0 12.4 39.0 50.0 41.8 31.7 13.5 41.0 33.3 12.6 40.2 MODEL: YCAL0045EC 95.0 100.0 EER TONS KW EER TONS KW EER 35.7 9.8 32.9 37.7 9.1 32.1 39.9 8.5 35.9 10.0 34.0 38.0 9.4 33.2 40.1 8.7 35.9 36.2 10.3 35.1 38.2 9.6 34.3 40.4 8.9 11.2 36.4 36.3 10.4 35.6 38.4 9.7 34.8 40.6 9.0 11.3 37.0 36.5 10.6 36.2 38.5 9.8 35.3 40.7 9.2 34.8 11.6 38.2 36.7 10.8 37.3 38.8 10.1 36.5 41.0 9.4 35.1 11.8 39.4 37.0 11.1 38.5 39.1 10.3 37.6 41.2 9.6 IPLV= 14.0 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 100.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 39.0 33.4 12.0 38.1 35.1 11.2 37.2 37.0 10.5 36.3 39.0 9.8 35.4 41.2 9.1 34.4 43.5 8.4 42.0 40.3 33.7 12.3 39.3 35.4 11.5 38.4 37.3 10.8 37.5 39.3 10.0 36.6 41.5 9.3 35.6 43.8 8.7 44.0 41.5 34.0 12.6 40.6 35.7 11.8 39.7 37.6 11.0 38.7 39.6 10.3 37.8 41.8 9.6 36.8 44.1 8.9 45.0 42.2 34.1 12.7 41.2 35.9 11.9 40.3 37.7 11.2 39.3 39.8 10.4 38.4 41.9 9.7 37.4 44.2 9.0 46.0 42.8 34.3 12.9 41.9 36.0 12.1 40.9 37.9 11.3 40.0 39.9 10.5 39.0 42.1 9.8 38.0 44.4 9.1 48.0 44.1 34.6 13.2 43.2 36.4 12.3 42.2 38.2 11.6 41.2 40.3 10.8 40.2 42.4 10.1 39.2 44.7 9.4 50.0 45.5 35.0 13.4 44.5 36.7 12.6 43.5 38.6 11.8 42.5 40.6 11.0 41.5 42.8 10.3 40.5 45.1 9.6 MODEL: YCAL0051EC IPLV= 14.3 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW 40.0 45.0 38.9 12.1 43.9 41.0 11.3 42.8 43.2 10.5 41.8 42.0 46.4 39.2 12.4 45.4 41.3 11.6 44.3 43.5 10.8 43.2 44.0 47.9 39.5 12.8 46.9 41.6 11.9 45.8 43.8 11.1 45.0 48.7 39.7 12.9 47.6 41.7 12.1 46.5 43.9 46.0 49.5 39.8 13.1 48.4 41.9 12.2 47.2 44.1 48.0 51.0 40.1 13.4 49.9 42.2 12.5 48.8 50.0 52.6 40.5 13.7 51.4 42.5 12.8 50.3 95.0 100.0 EER TONS KW EER TONS KW EER 45.6 9.8 40.7 48.1 9.1 39.7 50.8 8.4 45.9 10.1 42.1 48.4 9.4 41.1 51.1 8.7 44.7 46.2 10.4 43.6 48.7 9.6 42.5 51.4 8.9 11.3 45.4 46.3 10.5 44.3 48.9 9.8 43.2 51.6 9.1 11.4 46.1 46.5 10.6 45.0 49.0 9.9 43.9 51.7 9.2 44.4 11.7 47.6 46.8 10.9 46.5 49.3 10.2 45.3 52.1 9.4 44.7 12.0 49.1 47.1 11.2 48.0 49.7 10.4 46.8 52.4 9.7 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 16 YORK INTERNATIONAL FORM 150.64-EG1 MODEL: YCAL0041EC IPLV= 13.9 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 31.3 42.2 7.9 30.5 44.7 7.3 29.6 47.4 6.7 28.7 50.2 6.2 27.8 53.2 5.7 42.0 32.4 42.5 8.1 31.5 45.0 7.5 30.6 47.6 6.9 29.7 50.4 6.4 28.7 53.4 5.8 44.0 33.4 42.7 8.3 32.5 45.2 7.7 31.6 47.9 7.1 30.7 50.7 6.5 29.7 53.7 6.0 45.0 34.0 42.9 8.4 33.1 45.3 7.8 32.1 48.0 7.2 31.2 50.8 6.6 30.2 53.8 6.1 46.0 34.5 43.0 8.5 33.6 45.5 7.9 32.7 48.1 7.3 31.7 50.9 6.7 30.7 53.9 6.2 48.0 35.6 43.3 8.7 34.7 45.7 8.1 33.7 48.4 7.5 32.8 51.2 6.9 31.8 54.1 6.4 50.0 36.7 43.6 9.0 35.8 46.0 8.3 34.8 48.6 7.7 33.8 51.4 7.1 32.8 54.4 6.6 MODEL: YCAL0045EC IPLV= 14.0 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 33.5 45.9 7.8 32.5 48.6 7.2 31.5 51.4 6.6 30.4 54.4 6.1 29.3 57.5 5.6 42.0 34.6 46.2 8.0 33.6 48.9 7.4 32.6 51.7 6.8 31.5 54.7 6.3 30.4 57.8 5.7 44.0 35.8 46.5 8.2 34.8 49.2 7.6 33.7 52.0 7.0 32.6 55.0 6.5 31.5 58.1 5.9 45.0 36.4 46.7 8.4 35.4 49.4 7.7 34.3 52.1 7.1 33.2 55.1 6.6 32.0 58.3 6.0 46.0 37.0 46.9 8.5 36.0 49.5 7.8 34.9 52.3 7.2 33.8 55.3 6.7 32.6 58.5 6.1 48.0 38.2 47.2 8.7 37.2 49.8 8.0 36.0 52.7 7.4 34.9 55.6 6.8 33.7 58.8 6.3 50.0 39.4 47.6 8.9 38.4 50.2 8.3 37.2 53.0 7.6 36.1 56.0 7.0 34.9 59.1 6.5 MODEL: YCAL0051EC IPLV= 14.3 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 38.6 53.7 7.8 37.5 56.7 7.2 36.3 59.9 6.7 35.1 63.3 6.1 33.9 66.8 5.6 42.0 39.9 54.0 8.0 38.8 57.0 7.4 37.6 60.2 6.9 36.4 63.6 6.3 35.1 67.2 5.8 44.0 41.3 54.3 8.3 40.1 57.4 7.7 38.9 60.6 7.1 37.7 64.0 6.5 36.4 67.6 6.0 45.0 42.0 54.5 8.4 40.8 57.5 7.8 39.6 60.8 7.2 38.3 64.2 6.6 37.0 67.8 6.1 46.0 42.7 54.6 8.5 41.5 57.7 7.9 40.3 60.9 7.3 39.0 64.4 6.7 37.7 68.0 6.1 48.0 44.1 55.0 8.7 42.9 58.0 8.1 41.6 61.3 7.5 40.3 64.7 6.9 39.0 68.3 6.3 50.0 45.6 55.3 9.0 44.3 58.4 8.3 43.0 61.7 7.7 41.7 65.1 7.1 40.3 68.7 6.5 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 YORK INTERNATIONAL 17 Ratings - R-22 (60Hz - English Units) - Cont. MODEL: YCAL0055EC IPLV= 13.6 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 LCWT (°F) TONS KW 40.0 48.6 42.0 50.2 44.0 80.0 85.0 90.0 EER TONS KW EER TONS KW EER TONS KW 42.1 11.9 47.6 44.4 11.2 46.6 46.8 10.5 45.6 42.4 12.3 49.2 44.7 11.5 48.2 47.1 10.7 47.1 51.8 42.7 12.6 50.8 44.9 11.8 49.8 47.4 11.0 45.0 52.7 42.8 12.8 51.6 45.1 12.0 50.6 47.5 46.0 53.5 43.0 12.9 52.5 45.2 12.1 51.4 47.7 48.0 55.2 43.3 13.3 54.2 45.5 12.4 53.1 50.0 57.0 43.6 13.6 55.9 45.9 12.8 54.7 MODEL: YCAL0061EC 95.0 100.0 EER TONS KW EER TONS KW EER 49.4 9.7 44.6 52.2 9.1 43.5 55.1 8.4 49.7 10.0 46.1 52.5 9.3 44.9 55.4 8.7 48.7 50.0 10.3 47.6 52.8 9.6 46.4 55.7 8.9 11.2 49.5 50.2 10.4 48.4 52.9 9.7 47.2 55.9 9.0 11.3 50.3 50.3 10.6 49.1 53.1 9.9 48.0 56.1 9.2 48.0 11.6 51.9 50.6 10.9 50.7 53.4 10.1 49.5 56.4 9.4 48.3 11.9 53.6 50.9 11.2 52.4 53.7 10.4 51.1 56.7 9.7 IPLV= 14.2 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 100.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 56.8 49.8 12.1 55.6 52.6 11.3 54.5 55.5 10.5 53.3 58.7 9.8 52.0 62.0 9.1 50.8 65.5 8.4 42.0 58.7 50.2 12.4 57.5 53.0 11.5 56.3 56.0 10.8 55.0 59.1 10.0 53.8 62.5 9.3 52.5 66.0 8.7 44.0 60.6 50.6 12.7 59.4 53.4 11.8 58.1 56.4 11.0 56.9 59.6 10.3 55.6 62.9 9.6 54.2 66.5 8.9 45.0 61.5 50.9 12.8 60.3 53.6 12.0 59.1 56.6 11.2 57.8 59.8 10.4 56.5 63.2 9.7 55.1 66.7 9.0 46.0 62.5 51.1 13.0 61.3 53.9 12.1 60.0 56.8 11.3 58.7 60.0 10.6 57.4 63.4 9.8 56.0 67.0 9.1 48.0 64.5 51.5 13.3 63.2 54.3 12.4 61.9 57.3 11.6 60.6 60.5 10.8 59.2 63.9 10.1 57.8 67.5 9.4 50.0 66.5 52.0 13.6 65.2 54.8 12.7 63.9 57.8 11.9 62.5 61.0 11.1 61.1 64.4 10.3 59.7 68.0 9.6 MODEL: YCAL0065EC LCWT (°F) IPLV= 14.5 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 TONS KW 80.0 EER TONS KW 85.0 90.0 EER TONS KW EER TONS KW 95.0 100.0 EER TONS KW EER TONS KW EER 40.0 & & & & & & 59.9 61.4 10.6 58.5 64.8 9.8 57.2 68.4 9.1 55.8 72.2 8.5 42.0 64.5 55.7 12.4 63.2 58.7 11.6 61.8 61.9 10.8 60.5 65.3 10.1 59.1 68.9 9.4 57.6 72.8 8.7 44.0 66.5 56.2 12.7 65.2 59.2 11.9 63.9 62.5 11.1 62.5 65.9 10.3 61.0 69.5 9.6 59.6 73.4 8.9 45.0 67.6 56.5 12.8 66.3 59.5 12.0 64.9 62.7 11.2 63.5 66.2 10.4 62.0 69.8 9.7 60.5 73.7 9.0 46.0 68.7 56.8 13.0 67.3 59.8 12.1 65.9 63.0 11.3 64.5 66.5 10.6 63.0 70.1 9.8 61.5 74.0 9.1 48.0 70.8 57.3 13.3 69.5 60.4 12.4 68.0 63.6 11.6 66.5 67.1 10.8 65.0 70.8 10.1 63.5 74.7 9.4 50.0 73.1 57.9 13.6 71.6 61.0 12.7 70.2 64.2 11.9 68.7 67.7 11.1 67.1 71.4 10.3 65.5 75.3 9.6 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 18 YORK INTERNATIONAL FORM 150.64-EG1 MODEL: YCAL0055EC IPLV= 13.6 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 42.3 58.2 7.8 41.2 61.4 7.2 39.9 64.8 6.7 29.0 48.0 6.4 28.0 50.6 5.9 42.0 43.8 58.5 8.1 42.6 61.8 7.5 41.3 65.2 6.9 30.0 48.3 6.6 29.0 50.9 6.0 44.0 45.3 58.8 8.3 44.0 62.1 7.7 42.7 65.6 7.1 31.1 48.5 6.8 30.1 51.2 6.2 45.0 46.0 59.0 8.4 44.7 62.3 7.8 43.4 65.8 7.2 31.6 48.6 6.9 30.6 51.3 6.3 46.0 46.8 59.1 8.5 45.5 62.5 7.9 44.2 65.9 7.3 32.2 48.7 7.0 31.1 51.4 6.4 48.0 48.3 59.5 8.8 47.0 62.8 8.1 45.6 66.3 7.5 33.3 49.0 7.2 32.2 51.7 6.6 50.0 49.8 59.9 9.0 48.5 63.2 8.3 47.1 66.7 7.7 34.4 49.2 7.4 33.3 51.9 6.8 MODEL: YCAL0061EC IPLV= 14.2 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 49.5 69.2 7.8 48.2 73.1 7.2 46.8 77.2 6.7 45.4 81.5 6.2 34.7 63.9 5.9 42.0 51.1 69.7 8.0 49.8 73.6 7.4 48.4 77.8 6.9 46.9 82.1 6.3 35.9 64.3 6.1 44.0 52.9 70.2 8.2 51.5 74.1 7.6 50.0 78.3 7.1 48.5 82.7 6.5 37.2 64.7 6.2 45.0 53.7 70.5 8.4 52.3 74.4 7.7 50.9 78.6 7.2 49.3 83.0 6.6 37.8 64.9 6.3 46.0 54.6 70.7 8.5 53.2 74.7 7.8 51.7 78.9 7.2 50.2 83.3 6.7 38.5 65.1 6.4 48.0 56.4 71.3 8.7 54.9 75.3 8.0 53.4 79.4 7.4 51.8 83.9 6.9 39.8 65.6 6.6 50.0 58.2 71.8 8.9 56.7 75.8 8.2 55.1 80.0 7.6 53.5 84.5 7.0 41.1 66.0 6.8 MODEL: YCAL0065EC IPLV= 14.5 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 54.3 76.3 7.9 52.8 80.6 7.3 51.3 85.1 6.7 49.7 89.9 6.2 38.2 73.1 5.7 42.0 56.2 76.9 8.1 54.6 81.2 7.5 53.1 85.8 6.9 51.4 90.6 6.3 39.6 73.6 5.9 44.0 58.0 77.5 8.3 56.5 81.9 7.6 54.9 86.5 7.1 53.2 91.3 6.5 28.9 42.9 7.0 45.0 59.0 77.8 8.4 57.4 82.2 7.7 55.8 86.8 7.2 54.1 91.7 6.6 29.4 43.1 7.1 46.0 59.9 78.2 8.5 58.3 82.5 7.8 56.7 87.2 7.2 55.0 92.1 6.7 29.9 43.2 7.2 48.0 61.9 78.8 8.7 60.3 83.2 8.0 58.6 87.9 7.4 56.8 92.8 6.8 31.0 43.4 7.4 50.0 63.9 79.5 8.9 62.2 83.9 8.2 60.5 88.6 7.6 58.7 93.5 7.0 32.0 43.6 7.6 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 YORK INTERNATIONAL 19 Ratings - R-22 (60Hz - SI Units) MODEL: YCAL0041EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 LCWT (°C) KW KW COP KW KW COP 5.0 126.9 31.1 3.5 122.4 34.3 6.0 130.6 31.3 3.5 125.9 34.5 7.0 134.3 31.6 3.6 129.6 8.0 138.1 31.8 3.7 9.0 142.0 32.1 3.8 10.0 145.9 32.3 11.0 149.9 32.6 40.0 45.0 50.0 KW KW COP KW KW COP KW KW COP KW KW COP 3.1 117.6 37.9 2.7 112.5 41.9 2.4 107.1 46.4 2.1 101.3 51.5 1.8 3.1 121.0 38.1 2.8 115.8 42.1 2.4 110.3 46.6 2.1 104.4 51.7 1.8 34.7 3.2 124.5 38.3 2.8 119.2 42.3 2.5 113.6 46.9 2.2 107.6 51.9 1.9 133.2 35.0 3.3 128.1 38.6 2.9 122.7 42.6 2.6 116.9 47.1 2.2 110.9 52.1 1.9 137.0 35.2 3.4 131.7 38.8 3.0 126.1 42.8 2.6 120.3 47.3 2.3 114.1 52.4 2.0 3.9 140.8 35.5 3.4 135.4 39.1 3.0 129.7 43.1 2.7 123.8 47.6 2.3 117.5 52.6 2.0 3.9 144.6 35.8 3.5 139.1 39.3 3.1 133.3 43.4 2.7 127.3 47.8 2.4 120.9 52.8 2.1 MODEL: YCAL0045EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 138.1 34.2 3.5 132.3 37.5 3.1 126.4 41.3 2.7 120.4 45.6 2.4 114.1 50.4 2.0 107.3 55.8 1.8 6.0 142.1 34.5 3.6 136.2 37.8 3.1 130.2 41.6 2.8 124.1 45.8 2.4 117.7 50.6 2.1 110.7 56.0 1.8 7.0 146.1 34.7 3.6 140.1 38.1 3.2 134.1 41.9 2.8 127.9 46.1 2.5 121.4 50.9 2.2 114.3 56.3 1.9 8.0 150.2 35.0 3.7 144.1 38.4 3.3 138.0 42.2 2.9 131.7 46.4 2.5 125.0 51.2 2.2 117.9 56.6 1.9 9.0 154.3 35.3 3.8 148.2 38.7 3.4 142.0 42.5 3.0 135.5 46.7 2.6 128.7 51.5 2.3 121.5 56.9 1.9 10.0 158.5 35.7 3.8 152.3 39.0 3.4 146.0 42.8 3.0 139.4 47.1 2.7 132.5 51.9 2.3 125.2 57.2 2.0 11.0 162.7 36.0 3.9 156.4 39.3 3.5 150.0 43.1 3.1 143.3 47.4 2.7 136.4 52.2 2.4 128.9 57.5 2.0 MODEL: YCAL0051EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 159.2 39.9 3.5 152.4 43.8 3.1 145.7 48.3 2.7 138.8 53.2 2.4 131.6 58.8 2.0 123.9 64.8 1.8 6.0 163.9 40.1 3.6 157.0 44.1 3.2 150.2 48.5 2.8 143.2 53.5 2.4 135.8 59.1 2.1 127.9 65.2 1.8 7.0 168.6 40.4 3.7 161.7 44.3 3.2 154.7 48.8 2.8 147.5 53.8 2.5 140.0 59.4 2.2 132.0 65.5 1.9 8.0 173.5 40.7 3.8 166.4 44.6 3.3 159.3 49.1 2.9 152.0 54.1 2.5 144.4 59.7 2.2 136.2 65.8 1.9 9.0 178.3 41.0 3.8 171.2 44.9 3.4 164.0 49.4 3.0 156.5 54.4 2.6 148.7 60.0 2.3 140.4 66.2 2.0 10.0 183.3 41.3 3.9 176.0 45.2 3.5 168.7 49.7 3.1 161.1 54.7 2.7 153.2 60.3 2.3 144.7 66.5 2.0 11.0 188.3 41.6 4.0 180.9 45.5 3.5 173.4 50.0 3.1 165.7 55.0 2.7 157.7 60.7 2.4 149.0 66.9 2.1 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 20 YORK INTERNATIONAL FORM 150.64-EG1 MODEL: YCAL0055EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 172.2 43.1 3.5 166.0 47.5 3.1 159.3 52.3 2.7 152.2 57.7 2.4 144.6 63.6 2.1 102.4 49.2 1.8 6.0 177.4 43.4 3.5 170.9 47.7 3.1 164.1 52.6 2.8 156.8 58.0 2.4 149.0 63.9 2.1 105.7 49.4 1.9 7.0 182.6 43.6 3.6 176.0 48.0 3.2 169.0 52.9 2.8 161.6 58.3 2.5 153.6 64.3 2.2 109.0 49.6 1.9 8.0 187.9 43.9 3.7 181.1 48.3 3.3 173.9 53.2 2.9 166.3 58.6 2.6 158.2 64.6 2.2 112.4 49.8 2.0 9.0 193.3 44.2 3.8 186.4 48.5 3.4 179.0 53.4 3.0 171.1 58.9 2.6 162.9 64.9 2.3 115.9 50.1 2.0 10.0 198.8 44.5 3.9 191.7 48.8 3.5 184.1 53.7 3.1 176.1 59.2 2.7 167.7 65.3 2.3 119.4 50.3 2.1 11.0 204.4 44.8 4.0 197.1 49.1 3.5 189.4 54.0 3.1 181.1 59.6 2.7 172.5 65.6 2.4 122.9 50.5 2.2 MODEL: YCAL0061EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 201.3 51.1 3.5 193.8 56.4 3.1 186.0 62.2 2.7 177.8 68.7 2.4 169.3 75.8 2.1 160.3 83.6 1.8 6.0 207.2 51.5 3.6 199.6 56.8 3.1 191.6 62.6 2.8 183.2 69.2 2.4 174.4 76.3 2.1 165.2 84.1 1.8 7.0 213.3 51.9 3.6 205.4 57.2 3.2 197.3 63.1 2.8 188.7 69.6 2.5 179.7 76.8 2.2 170.2 84.7 1.9 8.0 219.5 52.3 3.7 211.4 57.6 3.3 203.0 63.5 2.9 194.2 70.1 2.5 185.1 77.3 2.2 175.4 85.2 1.9 9.0 225.7 52.7 3.8 217.5 58.0 3.4 208.9 63.9 3.0 199.9 70.5 2.6 190.5 77.8 2.3 143.0 63.5 2.0 10.0 232.1 53.1 3.9 223.7 58.4 3.4 214.9 64.4 3.0 205.7 71.0 2.7 196.0 78.3 2.3 147.3 63.9 2.1 11.0 238.6 53.5 4.0 230.0 58.9 3.5 221.0 64.8 3.1 211.6 71.5 2.7 201.7 78.8 2.4 151.7 64.2 2.1 MODEL: YCAL0065EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 221.3 56.6 3.5 213.0 62.3 3.1 204.4 68.7 2.7 195.3 75.7 2.4 185.7 83.6 2.1 175.5 92.3 1.8 6.0 227.7 57.1 3.6 219.3 62.8 3.2 210.5 69.2 2.8 201.2 76.3 2.4 191.3 84.2 2.1 180.9 92.9 1.8 7.0 234.3 57.6 3.6 225.7 63.3 3.2 216.7 69.7 2.8 207.2 76.9 2.5 197.1 84.8 2.2 186.5 93.6 1.9 8.0 241.1 58.1 3.7 232.2 63.8 3.3 223.0 70.3 2.9 213.3 77.4 2.5 203.0 85.4 2.2 192.1 94.2 1.9 9.0 247.9 58.6 3.8 238.9 64.3 3.4 229.4 70.8 3.0 219.5 78.0 2.6 209.0 86.0 2.3 197.9 94.9 2.0 10.0 254.9 59.1 3.9 245.7 64.9 3.4 236.0 71.4 3.0 225.8 78.6 2.7 215.1 86.7 2.3 162.8 73.4 2.0 11.0 262.1 59.6 4.0 252.6 65.4 3.5 242.7 71.9 3.1 232.3 79.2 2.7 221.3 87.3 2.4 167.7 74.0 2.1 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 YORK INTERNATIONAL 21 Ratings - R-22 (50Hz - English Units) MODEL: YCAL0041EC IPLV= 16.2 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW 40.0 30.4 23.6 13.6 29.8 25.1 12.6 29.1 42.0 31.4 23.8 13.9 30.8 25.3 12.9 30.1 44.0 32.4 24.0 14.3 31.8 25.5 13.3 45.0 33.0 24.1 14.4 32.3 25.6 46.0 33.5 24.2 14.6 32.8 25.7 48.0 34.5 24.5 15.0 33.8 50.0 35.6 24.7 15.3 34.9 90.0 95.0 100.0 EER TONS KW EER TONS KW EER TONS KW EER 26.7 11.7 28.5 28.4 10.8 27.9 30.2 10.0 27.2 32.2 9.2 26.9 12.0 29.5 28.6 11.1 28.8 30.4 10.3 28.1 32.3 9.5 31.1 27.1 12.3 30.4 28.8 11.4 29.8 30.6 10.6 29.1 32.5 9.7 13.4 31.6 27.2 12.5 30.9 28.9 11.6 30.2 30.7 10.7 29.5 32.6 9.9 13.6 32.1 27.3 12.6 31.4 29.0 11.7 30.7 30.8 10.8 30.0 32.7 10.0 25.9 13.9 33.1 27.5 12.9 32.5 29.2 12.0 31.7 31.0 11.1 31.0 33.0 10.3 26.2 14.2 34.2 27.7 13.2 33.5 29.4 12.3 32.8 31.2 11.4 32.0 33.2 10.5 MODEL: YCAL0045EC IPLV= 16.1 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 100.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 32.9 25.9 13.6 32.2 27.5 12.6 31.5 29.2 11.7 30.8 31.0 10.8 30.0 32.9 10.0 29.2 35.0 9.2 42.0 34.0 26.2 13.9 33.3 27.8 12.9 32.6 29.4 12.0 31.8 31.2 11.1 31.1 33.2 10.2 30.2 35.3 9.4 44.0 35.1 26.4 14.2 34.4 28.0 13.2 33.7 29.7 12.3 32.9 31.5 11.4 32.1 33.4 10.5 31.3 35.5 9.7 45.0 35.7 26.5 14.4 34.9 28.1 13.4 34.2 29.8 12.4 33.4 31.6 11.5 32.6 33.5 10.6 31.8 35.6 9.8 46.0 36.2 26.7 14.5 35.5 28.2 13.5 34.7 29.9 12.6 34.0 31.7 11.7 33.2 33.7 10.8 32.3 35.7 10.0 48.0 37.4 26.9 14.9 36.6 28.5 13.8 35.9 30.2 12.9 35.1 32.0 11.9 34.2 33.9 11.1 33.4 36.0 10.2 50.0 38.5 27.2 15.2 37.8 28.8 14.2 37.0 30.5 13.2 36.2 32.3 12.2 35.3 34.2 11.3 34.4 36.3 10.5 MODEL: YCAL0051EC IPLV= 15.7 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW 40.0 37.9 30.8 13.3 37.1 32.6 12.4 36.3 34.6 11.5 35.5 36.7 10.7 34.6 42.0 39.1 31.0 13.7 38.3 32.9 12.7 37.5 34.8 11.8 36.7 36.9 11.0 35.8 44.0 40.4 31.3 14.0 39.6 33.1 13.1 38.8 35.1 12.2 37.9 37.1 11.3 45.0 41.0 31.4 14.2 40.2 33.2 13.2 39.4 35.2 12.3 38.5 37.3 46.0 41.7 31.5 14.4 40.9 33.4 13.4 40.0 35.3 12.5 39.2 37.4 48.0 43.0 31.8 14.7 42.2 33.6 13.7 41.3 35.6 12.8 40.4 50.0 44.4 32.1 15.1 43.5 33.9 14.1 42.6 35.8 13.1 41.7 100.0 EER TONS KW EER 38.9 9.9 33.8 41.3 9.1 39.1 10.1 34.9 41.5 9.4 37.0 39.4 10.4 36.1 41.7 9.6 11.4 37.6 39.5 10.6 36.7 41.9 9.8 11.6 38.3 39.6 10.7 37.3 42.0 9.9 37.6 11.9 39.5 39.9 11.0 38.5 42.2 10.2 37.9 12.2 40.8 40.1 11.3 39.8 42.5 10.4 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 22 YORK INTERNATIONAL FORM 150.64-EG1 MODEL: YCAL0041EC IPLV= 16.2 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 26.5 40.0 34.3 8.5 25.7 36.5 7.8 25.0 39.0 7.1 24.1 41.6 6.5 23.2 44.4 5.8 27.4 42.0 34.5 8.7 26.6 36.7 8.0 25.8 39.2 7.3 25.0 41.8 6.7 24.1 44.6 6.0 28.3 44.0 34.7 9.0 27.5 36.9 8.2 26.7 39.4 7.5 25.9 42.0 6.9 24.9 44.8 6.2 28.8 45.0 34.8 9.1 28.0 37.0 8.4 27.2 39.5 7.6 26.3 42.1 7.0 25.4 44.9 6.3 29.3 46.0 34.9 9.2 28.5 37.1 8.5 27.6 39.6 7.8 26.8 42.2 7.1 25.8 45.0 6.4 30.2 48.0 35.1 9.5 29.4 37.3 8.7 28.6 39.8 8.0 27.7 42.4 7.3 26.7 45.2 6.6 31.2 50.0 35.3 9.7 30.4 37.5 8.9 29.5 40.0 8.2 28.6 42.6 7.5 27.6 45.4 6.8 MODEL: YCAL0045EC IPLV= 16.1 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 28.4 40.0 37.3 8.4 27.6 39.7 7.7 26.6 42.2 7.0 25.7 45.0 6.4 24.7 47.9 5.8 29.4 42.0 37.5 8.7 28.5 39.9 7.9 27.6 42.5 7.2 26.6 45.2 6.6 25.6 48.2 6.0 30.4 44.0 37.7 8.9 29.5 40.1 8.2 28.6 42.7 7.5 27.6 45.4 6.8 26.5 48.4 6.2 30.9 45.0 37.8 9.0 30.0 40.2 8.3 29.1 42.8 7.6 28.1 45.6 6.9 27.0 48.5 6.3 31.4 46.0 38.0 9.2 30.5 40.4 8.4 29.6 42.9 7.7 28.5 45.7 7.0 27.5 48.6 6.4 32.5 48.0 38.2 9.4 31.5 40.6 8.6 30.6 43.2 7.9 29.5 45.9 7.2 28.4 48.9 6.6 33.5 50.0 38.5 9.6 32.6 40.9 8.9 31.6 43.4 8.1 30.5 46.2 7.4 29.4 49.1 6.7 MODEL: YCAL0051EC IPLV= 15.7 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 32.8 40.0 43.8 8.4 31.9 46.4 7.7 30.9 49.3 7.1 29.8 52.3 6.5 28.7 55.4 5.9 34.0 42.0 44.0 8.6 33.0 46.7 7.9 32.0 49.5 7.3 30.9 52.5 6.7 29.8 55.7 6.1 35.1 44.0 44.3 8.9 34.2 46.9 8.2 33.1 49.8 7.5 32.0 52.8 6.9 30.9 56.0 6.3 35.7 45.0 44.4 9.0 34.7 47.0 8.3 33.7 49.9 7.6 32.6 52.9 7.0 31.4 56.1 6.4 36.3 46.0 44.5 9.1 35.3 47.2 8.4 34.2 50.0 7.7 33.1 53.0 7.1 32.0 56.2 6.5 37.5 48.0 44.7 9.4 36.5 47.4 8.6 35.4 50.3 7.9 34.3 53.3 7.3 33.1 56.5 6.6 38.8 50.0 45.0 9.6 37.7 47.7 8.9 36.6 50.5 8.2 35.4 53.6 7.5 34.2 56.8 6.8 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 YORK INTERNATIONAL 23 Ratings - R-22 (50Hz - English Units) - Cont. MODEL: YCAL0055EC IPLV= 15.0 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW 40.0 41.2 33.8 13.1 40.4 35.7 12.2 39.6 37.8 11.4 38.7 40.0 10.6 37.8 42.0 42.6 34.0 13.5 41.7 36.0 12.6 40.9 38.0 11.7 40.0 40.3 10.9 39.1 44.0 44.0 34.3 13.8 43.1 36.2 12.9 42.3 38.3 12.0 41.4 40.5 11.2 45.0 44.7 34.4 14.0 43.8 36.3 13.1 43.0 38.4 12.2 42.1 40.6 46.0 45.4 34.5 14.2 44.5 36.4 13.3 43.7 38.5 12.4 42.7 40.7 48.0 46.9 34.7 14.6 46.0 36.7 13.6 45.1 38.8 12.7 44.1 50.0 48.4 35.0 14.9 47.5 36.9 14.0 46.5 39.0 13.0 45.6 MODEL: YCAL0061EC 100.0 EER TONS KW EER 42.4 9.8 36.9 44.9 9.1 42.6 10.1 38.2 45.1 9.4 40.4 42.8 10.4 39.5 45.4 9.6 11.3 41.1 43.0 10.5 40.1 45.5 9.8 11.5 41.8 43.1 10.7 40.8 45.6 9.9 40.9 11.8 43.1 43.3 11.0 42.1 45.8 10.2 41.2 12.1 44.5 43.6 11.3 43.5 46.1 10.4 IPLV= 15.7 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 100.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 48.0 40.0 13.1 47.0 42.3 12.2 46.0 44.8 11.3 45.0 47.5 10.5 44.0 50.3 9.8 43.0 53.3 9.0 42.0 49.6 40.3 13.5 48.6 42.6 12.5 47.6 45.1 11.6 46.6 47.8 10.8 45.5 50.6 10.0 44.4 53.6 9.3 44.0 51.2 40.6 13.8 50.2 42.9 12.9 49.1 45.5 12.0 48.1 48.1 11.1 47.0 51.0 10.3 45.9 54.0 9.5 45.0 52.0 40.7 14.0 51.0 43.1 13.0 49.9 45.6 12.1 48.9 48.3 11.2 47.8 51.1 10.4 46.7 54.2 9.7 46.0 52.9 40.9 14.2 51.8 43.3 13.2 50.8 45.8 12.3 49.7 48.5 11.4 48.6 51.3 10.6 47.4 54.3 9.8 48.0 54.6 41.2 14.5 53.5 43.6 13.5 52.4 46.1 12.6 51.3 48.8 11.7 50.2 51.6 10.8 49.0 54.7 10.0 50.0 56.3 41.6 14.9 55.2 43.9 13.8 54.1 46.5 12.9 52.9 49.1 12.0 51.8 52.0 11.1 50.6 55.1 10.3 MODEL: YCAL0065EC IPLV= 15.8 AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW 40.0 52.5 44.2 13.1 51.4 46.7 12.2 50.3 49.4 11.3 49.2 52.3 10.5 48.1 42.0 54.2 44.5 13.4 53.1 47.1 12.5 52.0 49.8 11.6 50.9 52.7 10.8 49.7 44.0 55.9 44.9 13.8 54.8 47.5 12.8 53.7 50.2 11.9 52.5 53.1 11.1 45.0 56.8 45.1 13.9 55.7 47.7 13.0 54.6 50.4 12.1 53.4 53.3 46.0 57.7 45.3 14.1 56.6 47.9 13.1 55.4 50.6 12.2 54.2 53.5 48.0 59.6 45.7 14.4 58.4 48.3 13.4 57.2 51.0 12.5 56.0 50.0 61.4 46.1 14.7 60.2 48.7 13.7 59.0 51.5 12.8 57.7 100.0 EER TONS KW EER 55.4 9.7 46.9 58.7 9.0 55.8 10.0 48.5 59.1 9.2 51.3 56.2 10.2 50.1 59.6 9.5 11.2 52.2 56.4 10.4 50.9 59.8 9.6 11.3 53.0 56.7 10.5 51.7 60.0 9.7 54.0 11.6 54.7 57.1 10.8 53.4 60.4 10.0 54.4 11.9 56.5 57.5 11.0 55.1 60.9 10.2 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 24 YORK INTERNATIONAL FORM 150.64-EG1 MODEL: YCAL0055EC IPLV= 15.0 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 36.0 40.0 47.5 8.4 35.0 50.3 7.7 33.9 53.3 7.1 32.8 56.4 6.5 31.7 59.7 6.0 37.2 42.0 47.8 8.6 36.2 50.6 8.0 35.1 53.6 7.3 34.0 56.7 6.7 32.8 60.0 6.2 38.5 44.0 48.0 8.9 37.4 50.9 8.2 36.3 53.8 7.6 35.2 57.0 6.9 34.0 60.3 6.4 39.1 45.0 48.2 9.0 38.1 51.0 8.3 36.9 54.0 7.7 35.8 57.1 7.0 34.6 60.5 6.4 39.8 46.0 48.3 9.1 38.7 51.1 8.4 37.6 54.1 7.8 36.4 57.3 7.1 35.2 60.6 6.5 41.1 48.0 48.5 9.4 40.0 51.4 8.7 38.8 54.4 8.0 37.6 57.6 7.3 36.4 60.9 6.7 42.4 50.0 48.8 9.7 41.3 51.7 8.9 40.1 54.7 8.2 38.9 57.9 7.6 37.6 61.2 6.9 MODEL: YCAL0061EC IPLV= 15.7 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 41.9 40.0 56.5 8.3 40.7 59.9 7.7 39.5 63.5 7.0 38.2 67.3 6.4 36.8 71.3 5.9 43.3 42.0 56.8 8.6 42.1 60.3 7.9 40.9 63.8 7.2 39.5 67.7 6.6 38.1 71.7 6.1 44.8 44.0 57.2 8.8 43.6 60.6 8.1 42.3 64.3 7.4 40.9 68.1 6.8 39.5 72.2 6.2 45.5 45.0 57.4 8.9 44.3 60.8 8.2 43.0 64.5 7.5 41.6 68.3 6.9 40.2 72.4 6.3 46.3 46.0 57.6 9.0 45.0 61.0 8.3 43.7 64.7 7.6 42.3 68.5 7.0 40.8 72.6 6.4 47.8 48.0 57.9 9.3 46.5 61.4 8.5 45.1 65.1 7.9 43.7 68.9 7.2 42.2 73.0 6.6 49.3 50.0 58.3 9.5 48.0 61.8 8.8 46.6 65.5 8.1 45.2 69.4 7.4 43.7 73.5 6.8 MODEL: YCAL0065EC IPLV= 15.8 AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 45.6 40.0 62.2 8.3 44.3 65.9 7.6 42.8 69.9 7.0 41.3 74.2 6.3 39.6 78.7 5.8 47.2 42.0 62.7 8.5 45.8 66.4 7.8 44.3 70.4 7.2 42.8 74.7 6.5 41.1 79.2 5.9 48.8 44.0 63.1 8.7 47.4 66.9 8.0 45.9 70.9 7.4 44.3 75.2 6.7 42.6 79.8 6.1 49.6 45.0 63.3 8.8 48.2 67.1 8.1 46.7 71.2 7.5 45.1 75.5 6.8 43.4 80.1 6.2 50.4 46.0 63.6 9.0 49.0 67.4 8.2 47.4 71.4 7.6 45.8 75.7 6.9 44.1 80.3 6.3 52.0 48.0 64.0 9.2 50.6 67.9 8.5 49.0 72.0 7.8 47.4 76.3 7.1 35.1 54.3 7.2 53.7 50.0 64.5 9.4 52.2 68.4 8.7 50.6 72.5 8.0 49.0 76.8 7.3 36.3 54.6 7.4 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 YORK INTERNATIONAL 25 Ratings - R-22 (50Hz - SI Units) MODEL: YCAL0041EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 LCWT (°C) KW KW COP KW KW COP 5.0 107.8 24.3 3.9 103.7 27.1 6.0 111.0 24.5 4.0 106.9 27.3 7.0 114.2 24.7 4.1 110.0 8.0 117.5 24.9 4.2 9.0 120.8 25.1 4.3 10.0 124.2 25.3 11.0 127.6 25.5 40.0 45.0 50.0 KW KW COP KW KW COP KW KW COP KW KW COP 3.4 99.6 30.3 3.0 95.2 33.9 2.6 90.4 38.1 2.2 85.1 42.8 1.9 3.5 102.6 30.5 3.0 98.1 34.1 2.6 93.3 38.2 2.3 87.8 43.0 1.9 27.5 3.6 105.7 30.6 3.1 101.1 34.3 2.7 96.1 38.4 2.3 90.6 43.2 2.0 113.2 27.6 3.7 108.8 30.8 3.2 104.1 34.5 2.8 99.1 38.6 2.4 93.4 43.3 2.0 116.4 27.9 3.7 112.0 31.0 3.3 107.2 34.6 2.8 102.0 38.8 2.4 96.3 43.5 2.1 4.4 119.7 28.1 3.8 115.2 31.2 3.3 110.3 34.8 2.9 105.0 39.0 2.5 99.2 43.7 2.1 4.5 123.1 28.3 3.9 118.4 31.4 3.4 113.5 35.0 3.0 108.1 39.2 2.6 102.2 43.9 2.2 MODEL: YCAL0045EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 116.7 26.7 3.9 112.2 29.7 3.4 107.4 33.1 3.0 102.2 36.9 2.6 96.7 41.3 2.2 90.6 46.3 1.8 6.0 120.2 26.9 4.0 115.6 29.9 3.5 110.7 33.3 3.0 105.4 37.1 2.6 99.7 41.5 2.2 93.5 46.5 1.9 7.0 123.7 27.1 4.1 119.0 30.1 3.6 114.0 33.5 3.1 108.6 37.3 2.7 102.8 41.7 2.3 96.5 46.7 1.9 8.0 127.2 27.3 4.2 122.4 30.3 3.7 117.3 33.7 3.2 111.9 37.6 2.7 106.0 41.9 2.4 99.6 46.9 2.0 9.0 130.8 27.6 4.2 125.9 30.6 3.7 120.7 33.9 3.3 115.2 37.8 2.8 109.2 42.2 2.4 102.7 47.1 2.0 10.0 134.4 27.8 4.3 129.4 30.8 3.8 124.2 34.2 3.3 118.6 38.0 2.9 112.4 42.4 2.5 105.8 47.3 2.1 11.0 138.1 28.1 4.4 133.0 31.1 3.9 127.7 34.4 3.4 122.0 38.2 2.9 115.7 42.6 2.5 109.0 47.6 2.2 MODEL: YCAL0051EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 LCWT (°C) KW KW COP KW KW COP KW KW COP 5.0 134.2 31.6 3.9 129.2 35.1 3.4 123.9 39.0 6.0 138.2 31.9 3.9 133.1 35.3 3.5 127.7 39.2 7.0 142.3 32.1 4.0 137.1 35.5 3.5 131.5 8.0 146.4 32.3 4.1 141.1 35.8 3.6 9.0 150.6 32.5 4.2 145.2 36.0 3.7 10.0 154.9 32.8 4.3 149.3 36.2 11.0 159.2 33.0 4.4 153.5 36.5 45.0 50.0 KW KW COP KW KW COP KW KW COP 2.9 118.2 43.4 2.5 112.0 48.2 2.2 105.3 53.6 1.9 3.0 121.8 43.6 2.6 115.5 48.5 2.2 108.7 53.9 1.9 39.4 3.1 125.5 43.8 2.7 119.1 48.7 2.3 112.1 54.1 2.0 135.4 39.6 3.2 129.3 44.0 2.7 122.7 48.9 2.4 115.6 54.3 2.0 139.3 39.9 3.2 133.1 44.3 2.8 126.4 49.1 2.4 119.2 54.6 2.1 3.8 143.4 40.1 3.3 137.0 44.5 2.9 130.1 49.4 2.5 122.8 54.8 2.1 3.9 147.4 40.4 3.4 140.9 44.7 2.9 134.0 49.6 2.5 126.5 55.1 2.2 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 26 YORK INTERNATIONAL FORM 150.64-EG1 MODEL: YCAL0055EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 146.1 34.7 3.8 140.9 38.4 3.3 135.3 42.5 2.9 129.3 47.1 2.5 122.9 52.2 2.2 115.9 57.8 1.9 6.0 150.5 34.9 3.9 145.1 38.6 3.4 139.4 42.7 3.0 133.3 47.3 2.6 126.7 52.5 2.3 119.6 58.1 1.9 7.0 155.0 35.1 4.0 149.5 38.8 3.5 143.6 42.9 3.1 137.4 47.6 2.7 130.6 52.7 2.3 123.3 58.4 2.0 8.0 159.5 35.3 4.1 153.9 39.0 3.6 147.9 43.1 3.2 141.5 47.8 2.7 134.6 53.0 2.4 127.1 58.7 2.0 9.0 164.2 35.5 4.2 158.3 39.2 3.7 152.2 43.3 3.2 145.6 48.0 2.8 138.6 53.2 2.4 131.0 58.9 2.1 10.0 168.9 35.7 4.3 162.9 39.4 3.8 156.6 43.6 3.3 149.9 48.2 2.9 142.7 53.4 2.5 134.9 59.2 2.1 11.0 173.7 36.0 4.4 167.5 39.6 3.9 161.1 43.8 3.4 154.2 48.5 2.9 146.8 53.7 2.6 138.9 59.5 2.2 MODEL: YCAL0061EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 170.1 41.1 3.8 163.9 45.5 3.3 157.4 50.5 2.9 150.5 56.0 2.5 143.0 62.2 2.2 134.7 69.0 1.9 6.0 175.2 41.3 3.9 168.8 45.8 3.4 162.2 50.7 3.0 155.1 56.3 2.6 147.5 62.5 2.2 139.0 69.4 1.9 7.0 180.3 41.6 4.0 173.8 46.1 3.5 167.0 51.1 3.0 159.8 56.7 2.6 152.0 62.9 2.3 143.3 69.8 2.0 8.0 185.6 41.9 4.1 178.9 46.4 3.6 171.9 51.4 3.1 164.6 57.0 2.7 156.6 63.3 2.3 147.8 70.2 2.0 9.0 190.9 42.2 4.1 184.0 46.7 3.6 176.9 51.7 3.2 169.4 57.3 2.8 161.2 63.6 2.4 152.2 70.6 2.0 10.0 196.4 42.5 4.2 189.3 47.0 3.7 182.0 52.0 3.3 174.3 57.6 2.8 165.9 64.0 2.4 156.7 71.0 2.1 11.0 201.9 42.8 4.3 194.7 47.3 3.8 187.2 52.3 3.3 179.3 58.0 2.9 170.7 64.3 2.5 161.3 71.4 2.1 MODEL: YCAL0065EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 186.0 45.4 3.8 179.1 50.2 3.3 171.9 55.6 2.9 164.0 61.7 2.5 155.3 68.5 2.1 145.5 76.2 1.8 6.0 191.4 45.7 3.9 184.4 50.5 3.4 177.0 56.0 3.0 169.0 62.1 2.6 160.2 69.0 2.2 150.2 76.7 1.9 7.0 197.0 46.0 4.0 189.8 50.9 3.5 182.2 56.4 3.0 174.1 62.5 2.6 165.1 69.4 2.3 155.0 77.2 1.9 8.0 202.7 46.4 4.0 195.3 51.3 3.5 187.6 56.7 3.1 179.3 62.9 2.7 170.1 69.9 2.3 159.9 77.7 2.0 9.0 208.4 46.8 4.1 200.9 51.6 3.6 193.0 57.1 3.2 184.5 63.3 2.7 175.2 70.3 2.4 164.8 78.1 2.0 10.0 214.3 47.1 4.2 206.6 52.0 3.7 198.5 57.5 3.2 189.8 63.8 2.8 180.3 70.8 2.4 169.8 78.6 2.1 11.0 220.3 47.5 4.3 212.4 52.4 3.8 204.1 58.0 3.3 195.2 64.2 2.9 185.6 71.3 2.5 174.9 79.2 2.1 NOTES: 1. kW = Compressor Input Power 2. EER = Chiller EER (includes power from compressors, fans, and the control panels 0.8 kW) 3. LCWT = Leaving Chilled Water Temperature 4. Ratings are based upon 2.4 GPM cooler water per ton and 0.0001 fouling factor 5. Rated in accordance with ARI Standard 550/590-98 6. The shaded points are certified in accordance with ARI Standard 550/590-98 YORK INTERNATIONAL 27 Part Load Ratings - R-22 (English Units) YCAL0041 % FULL LOAD DISPL. 100.0 75.0 50.0 25.0 TONS 35.0 28.2 20.2 10.6 KW YCAL0055 Ambient °F 38.2 24.5 14.0 6.1 IPLV: 14.0 EER 95.0 83.3 69.7 55.0 UNIT EER 9.6 11.2 14.4 17.0 % FULL LOAD DISPL. 100.0 73.5 47.0 23.5 TONS 47.6 37.2 25.0 13.0 TONS 37.8 30.3 22.1 10.8 KW Ambient °F 41.8 26.0 15.5 6.2 IPLV: 14.1 EER 28 TONS 43.5 33.7 24.4 13.3 KW UNIT EER 95.0 81.9 66.5 55.0 9.6 11.4 14.6 16.3 Ambient °F UNIT EER YCAL0061 95.0 83.0 70.0 55.0 UNIT EER 9.6 11.5 14.5 17.0 % FULL LOAD DISPL. 100.0 69.3 46.2 23.1 TONS 55.7 42.4 30.1 15.7 KW 62.9 35.8 20.4 9.1 IPLV: 14.3 EER YCAL0051 % FULL LOAD DISPL. 100.0 69.2 48.3 20.9 Ambient °F 52.8 32.3 17.2 7.8 IPLV: 13.6 EER YCAL0045 % FULL LOAD DISPL. 100.0 73.2 50.0 23.2 KW 95.0 80.7 67.5 55.0 9.6 11.9 15.2 17.5 Ambient °F UNIT EER YCAL0065 Ambient °F 48.7 28.3 17.2 7.2 IPLV: 14.4 EER 95.0 81.4 68.6 55.0 UNIT EER 9.6 11.9 14.6 18.7 % FULL LOAD DISPL. 100.0 71.5 50.0 21.5 TONS 60.0 47.4 34.7 16.2 KW 68.3 40.3 25.3 9.0 IPLV: 14.5 EER 95.0 82.4 69.6 55.0 9.6 12.1 14.5 18.2 YORK INTERNATIONAL FORM 150.64-EG1 Part Load Ratings - R-22 (SI) YCAL0041 % FULL LOAD DISPL. 100.0 75.0 50.0 25.0 Comp KW KW 123.0 99.0 71.2 37.4 YCAL055 Ambient °C 38.2 35.0 24.5 28.5 14.0 21.0 6.1 12.8 IPLV: 4.10 COP UNIT COP 2.8 3.3 4.2 5.0 % FULL LOAD DISPL. 100.0 73.5 47.0 23.5 KW 167.3 130.8 87.8 45.6 YCAL0045 % FULL LOAD DISPL. 100.0 73.2 50.0 23.2 Comp KW KW 133.1 106.5 77.6 37.9 Ambient °C 41.8 35.0 26.0 28.3 15.5 21.1 6.2 12.8 IPLV: 4.12 COP Comp KW KW 153.1 118.5 85.7 46.8 52.8 35.0 32.3 27.7 17.2 19.2 7.8 12.8 IPLV: 4.00 COP UNIT COP 2.8 3.4 4.3 4.8 UNIT COP 2.8 3.4 4.2 5.0 % FULL LOAD DISPL. 100.0 69.3 46.2 23.1 KW 195.8 149.0 106.0 55.3 Comp KW Ambient °C 62.9 35.0 35.8 27.0 20.4 19.7 9.1 12.8 IPLV: 4.18 COP UNIT COP 2.8 3.5 4.5 5.1 YCAL0065 Ambient °C 48.7 35.0 28.3 27.5 17.2 20.3 7.2 12.8 IPLV: 4.23 COP YORK INTERNATIONAL Ambient °C YCAL0061 YCAL0051 % FULL LOAD DISPL. 100.0 69.2 48.3 20.9 Comp KW UNIT COP 2.8 3.5 4.3 5.5 % FULL LOAD DISPL. 100.0 71.5 50.0 21.5 KW 211.1 166.6 121.9 56.9 Comp KW Ambient °C 68.3 35.0 40.3 28.0 25.3 20.9 9.0 12.8 IPLV: 4.24 COP UNIT SCOP 2.8 3.6 4.3 5.3 29 Physical Data 60Hz Dimension YCAL Model No. General Unit Data NumNomiber of nal Length Width Height RefrigTons, erant R-22 Circuits Refrigerant Charge, Operating, R-22 (lbs) Oil Charge, gallons ckt1/ckt2 ckt1/ckt2 Nominal Compressor Capacity Shipping Weight Operating Weight Circuit 1 AlumiAlumiCopper Copper num num ComFin Fin Fin Fin presCoils, Coils, Coils, Coils, sor 1 lbs lbs lbs lbs 2942 3300 2967 3325 10 Ciruict 2 Compressor 2 Compressor 3 Compressor 4 Compressor 5 Compressor 6 10 - 10 10 - 0041 144.8 90.6 47.8 34.9 2 35/35 1.7/1.7 0045 144.8 90.6 47.8 38.0 2 40/35 1.7/1.7 2968 3326 3001 3359 12 12 - 10 10 - 0051 144.8 90.6 47.8 43.4 2 40/45 1.7/2.2 3448 3985 3480 4017 12 12 - 13 15 - 0055 144.8 90.6 62.6 47.4 2 50/50 2.2/2.2 3558 4035 3595 4073 15 13 - 13 15 - 0061 144.8 90.6 62.6 56.0 2 55/55 2.3/2.2 3863 4436 3908 4481 20 15 - 15 15 - 0065 153.6 90.6 62.6 60.1 2 60/55 2.3/2.2 4097 4703 4142 4748 20 20 - 15 15 - 50Hz Dimension General Unit Data NumRefrigerant ber of Charge, RefrigYCAL Nomi- erant Operating, Model nal Circuits R-22 (kg) No. Length Width Height KW, R-22 ckt1/ckt2 Nominal Compressor Capacity Oil Charge, Shipping Weight liters ckt1/ckt2 Operating Weight Circuit 1 Alumi- Cop- Alumi- Cop- Comnum Fin per Fin num Fin per Fin presCoils, lb Coils, lb Coils, lb Coils, lb sor 1 Circuit 2 Compressor 2 Compressor 3 Compressor 4 Compressor 5 Compressor 6 0041 145.8 91.20 47.75 29.6 2.0 35.0 / 35.0 1.7 / 1.7 2942.0 3300.0 2967.0 3325.0 8.3 8.3 - 8.3 8.3 - 0045 145.8 91.20 47.75 32.3 2.0 40.0 / 35.0 1.7 / 1.7 2968.0 3326.0 3001.0 3359.0 10.0 10.0 - 8.3 8.3 - 0051 145.8 91.20 47.75 37.3 2.0 40.0 / 45.0 1.7 / 2.2 3448.0 3985.0 3480.0 4017.0 10.0 10.0 - 10.8 12.5 - 0055 145.8 91.20 62.73 40.2 2.0 50.0 / 50.0 2.2 / 2.2 3558.0 4035.0 3595.0 4073.0 12.5 10.8 - 10.8 12.5 - 0061 145.8 91.20 62.73 47.6 2.0 55.0 / 55.0 2.3 / 2.2 3863.0 4436.0 3908.0 4481.0 16.7 12.5 - 12.5 12.5 - 0065 154.6 91.20 62.73 50.9 2.0 60.0 / 55.0 2.3 / 2.2 4097.0 4703.0 4142.0 4748.0 16.7 16.7 - 12.5 12.5 - 30 YORK INTERNATIONAL FORM 150.64-EG1 60Hz Condenser Condenser Fans, Low Sound Number of Rows Total Face Area ft2 Ckt. 1/Ckt. 2 Fins per Inch Number of Fans Ckt. 1/Ckt. 2 Fan Power hp/fan Fan RPM Condenser Fans, Ultra Quiet Total Chiller CFM Number of Fans ckt1/ckt2 Evaporator MaxiMaxiMini- Maximum mum mum mum RefrigChiller Chiller Total Water Water Fan erant Fan hp Chiller Volume, Side Water Water RPM Side CFM gallons PresFlow Flow Pressure, Rate, Rate, sure, PSIG gpm gpm PSIG Nominal Water Connections Size, inches 87.0 2/2 17 2/2 2 1140 47400 2/2 2 838 47400 2.7 300 450 40 200 3 87.0 2/2 17 2/2 2 1140 47400 2/2 2 838 47400 3.5 300 450 40 200 3 87.0 3/3 17 2/2 2 1140 47400 2/2 2 838 47400 3.5 300 450 40 200 3 116.0 2/2 17 2/2 2 1140 52000 2/2 2 838 52000 4.1 300 450 60 300 3 116.0 3/2 17 2/2 2 1140 52000 2/2 2 838 52000 4.9 300 450 60 300 3 128.0 3/3 13 2/2 2 1140 52000 2/2 2 838 52000 4.9 300 450 60 300 3 50Hz Condenser Total Face Area m2 Condenser Fans, Low Sound Number of Rows Fins per cm Ckt. 1/Ckt. 2 Fan Number of Power Fans kw/fan Condenser Fans, Ultra Quiet Number of Fans Fan RPM Total Chiller fpm Ckt. 1/Ckt. 2 Fan Fan Power RPM kw/fan ckt1/ckt2 Evaporator Maximum Total Water Water Chiller Volume, Side CFM gallons Pressure, psig Maximum Refrigerant Side Pressure, psig Minimum Chiller Water Flow Rate, gpm Maximum Nominal Chiller Water ConWater nections Flow Size, inches Rate, gpm 87.0 2.0 / 2.0 17.0 2.0 / 2.0 1.2 950.0 39500.0 2.0 / 2.0 1.2 698.3 39500.0 2.7 300.0 450.0 40.0 200.0 3.0 87.0 2.0 / 2.0 17.0 2.0 / 2.0 1.2 950.0 39500.0 2.0 / 2.0 1.2 698.3 39500.0 3.5 300.0 450.0 40.0 200.0 3.0 87.0 3.0 / 3.0 17.0 2.0 / 2.0 1.2 950.0 39500.0 2.0 / 2.0 1.2 698.3 39500.0 3.5 300.0 450.0 40.0 200.0 3.0 116.0 2.0 / 2.0 17.0 2.0 / 2.0 1.2 950.0 43333.3 2.0 / 2.0 1.2 698.3 43333.3 4.1 300.0 450.0 60.0 300.0 3.0 116.0 3.0 / 2.0 17.0 2.0 / 2.0 1.2 950.0 43333.3 2.0 / 2.0 1.2 698.3 43333.3 4.9 300.0 450.0 60.0 300.0 3.0 128.0 3.0 / 3.0 13.0 2.0 / 2.0 1.2 950.0 43333.3 2.0 / 2.0 1.2 698.3 43333.3 4.9 300.0 450.0 60.0 300.0 3.0 YORK INTERNATIONAL 31 Sound Data YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 32 63 92 92 91 93 93 94 8000 74 74 75 77 77 77 dBA 92 92 92 95 95 95 63 92 92 91 93 93 94 60Hz Line Frequency Low Noise Fan with compressor sound blankets installed R-22 125 250 500 1000 2000 4000 91 92 90 86 81 77 91 92 90 86 81 77 92 92 90 86 81 77 95 95 93 89 84 80 95 95 93 89 84 80 94 95 93 89 84 80 8000 73 73 73 76 76 75 dBA 91 91 91 94 94 94 63 94 94 94 96 96 96 60Hz Line Frequency Ultra Quiet Fan R-22 500 1000 87 83 87 83 88 84 90 87 90 87 90 87 8000 74 74 75 77 77 77 dBA 88 88 90 92 92 92 8000 73 73 73 76 76 75 dBA 87 87 88 91 91 91 63 94 94 94 96 96 96 125 91 91 92 95 95 94 125 88 88 90 93 93 92 250 92 92 92 95 95 95 60Hz Line Frequency Low Noise Fan R-22 500 1000 90 86 90 86 91 87 93 90 93 90 93 90 250 88 88 89 91 91 91 2000 81 81 82 85 86 86 2000 79 79 80 83 84 84 4000 77 77 78 81 82 82 4000 75 75 76 79 80 81 60Hz Line Frequency Ultra Quiet Fan with compressor sound blankets installed R-22 125 250 500 1000 2000 4000 88 88 85 82 77 74 88 88 85 82 77 74 90 89 86 83 78 74 93 91 89 85 81 77 93 91 89 85 81 78 92 91 89 86 81 78 YORK INTERNATIONAL FORM 150.64-EG1 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 YCAL0041 YCAL0045 YCAL0051 YCAL0055 YCAL0061 YCAL0065 63 88 88 88 89 90 90 8000 71 71 72 74 74 73 dBA 88 88 89 91 92 92 63 88 88 88 89 90 90 50Hz Line Frequency Low Noise Fan with compressor sound blankets installed R-22 125 250 500 1000 2000 4000 87 88 86 82 77 73 87 88 86 82 77 73 89 89 86 82 77 73 92 92 89 85 80 76 91 91 89 85 80 76 91 91 89 85 80 77 8000 69 69 69 72 72 72 dBA 87 87 88 90 90 90 63 90 90 90 92 92 92 50Hz Line Frequency Ultra Quiet Fan R-22 500 1000 84 80 84 80 85 81 87 84 87 84 87 84 8000 71 71 72 74 74 73 dBA 85 85 87 89 89 89 8000 69 69 69 72 72 72 dBA 84 84 84 87 87 87 63 90 90 90 92 92 92 YORK INTERNATIONAL 125 87 87 89 92 91 91 125 84 84 88 90 90 89 250 88 88 89 92 91 91 50Hz Line Frequency Low Noise Fan R-22 500 1000 87 83 87 83 87 83 90 86 90 86 90 86 250 84 84 86 88 88 87 2000 78 78 79 82 82 83 2000 75 75 78 80 81 81 4000 74 74 75 78 78 79 4000 72 72 73 76 77 78 50Hz Line Frequency Ultra Quiet Fan with compressor sound blankets installed R-22 125 250 500 1000 2000 4000 84 84 82 78 73 70 84 84 82 78 73 70 88 86 82 79 74 71 90 88 85 82 77 74 90 88 85 82 77 74 89 87 85 82 77 74 33 Dimensions - YCAL0041 (English) 6 3/4" 3 1/4" 3 15/16" 7/8" TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN ELECTRICAL ACCESS PANEL 47 3/4" 46 15/16" 34 5/8" 9 15/16" 15 3/4" LIQUID OUT 3" VICTAULIC (typ) 12 5/8" 45 1/8" 90 1/4" BASE WIDTH LEFT END Aluminum YCAL 0041 Copper Center of Gravity (in.) X Y 59.6 43.6 YCAL 0041 Center of Gravity (in.) X Y 63.6 43.7 NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 6'; rear to wall – 6'; cooler end to wall – 4'0"; coil end to wall - 6'; top – no obstructions allowed; distance between adjacent units – 10'. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 6". 34 YORK INTERNATIONAL FORM 150.64-EG1 9/16" DIA MOUNTING HOLES(typ) 1 1/16" COIL END COOLER END 90 9/16" END CAP WIDTH 45 5/16" 1 1/16" 9 13/16" ORIGIN 9 13/16" TOP VIEW 21 13/16" Y X CG 5 5/16" 38" CONTROL PANEL 25 3/8" B B 13 5/8" TWO LIFTING HOLES BOTH SIDES Z 13 15/16" 15 1/16" 144 13/16" C G X YORK INTERNATIONAL FRONT VIEW 35 Dimensions - YCAL0045 (English) 6 3/4" 3 1/4" 3 15/16" 7/8" TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN ELECTRICAL ACCESS PANEL 47 3/4" 46 15/16" 34 5/8" 9 15/16" 15 3/4" LIQUID OUT 3" VICTAULIC (typ) 12 5/8" 45 1/8" 90 1/4" BASE WIDTH LEFT END Aluminum YCAL 0045 Copper Center of Gravity (in.) X Y 59.2 43.5 YCAL 0045 Center of Gravity (in.) X Y 63.2 43.7 NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 6'; rear to wall – 6'; cooler end to wall – 4'0"; coil end to wall - 6'; top – no obstructions allowed; distance between adjacent units – 10'. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 6". 36 YORK INTERNATIONAL FORM 150.64-EG1 9/16" DIA MOUNTING HOLES(typ) 1 1/16" COIL END COOLER END 90 9/16" END CAP WIDTH 45 5/16" 1 1/16" 9 13/16" ORIGIN 9 13/16" TOP VIEW 20 1/16" Y X CG 5 5/16" 38" CONTROL PANEL 25 3/8" B B 13 5/8" TWO LIFTING HOLES BOTH SIDES Z 13 15/16" 15 1/16" 144 13/16" C G X YORK INTERNATIONAL FRONT VIEW 37 Dimensions - YCAL0051 (English) 6 3/4" 3 1/4" 3 15/16" 7/8" TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN ELECTRICAL ACCESS PANEL 47 3/4" 46 15/16" 34 5/8" 9 15/16" 15 3/4" LIQUID OUT 3" VICTAULIC (typ) 12 5/8" 45 1/8" 90 1/4" BASE WIDTH LEFT END Aluminum YCAL 0051 Copper Center of Gravity (in.) X Y 59.2 42.6 YCAL 0051 Center of Gravity (in.) X Y 64.3 42.9 NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 6'; rear to wall – 6'; cooler end to wall – 4'0"; coil end to wall - 6'; top – no obstructions allowed; distance between adjacent units – 10'. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 6". 38 YORK INTERNATIONAL FORM 150.64-EG1 9/16" DIA MOUNTING HOLES(typ) 1 1/16" COIL END COOLER END 90 9/16" END CAP WIDTH 45 5/16" 1 1/16" 9 13/16" ORIGIN 9 13/16" TOP VIEW 20 1/16" Y X CG 5 5/16" 38" CONTROL PANEL 25 3/8" B B 13 5/8" TWO LIFTING HOLES BOTH SIDES Z 13 15/16" 15 1/16" 144 13/16" C G X YORK INTERNATIONAL FRONT VIEW 39 Dimensions - YCAL0055EC - (English) 6 3/4" 3 1/4" 3 15/16" 7/8" TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN 62 5/8" ELECTRICAL ACCESS PANEL 61 7/8" 9 15/16" 15 3/4" LIQUID OUT 34 11/16" 3" VICTAULIC (typ) 12 5/8" 45 1/8" 90 1/4" BASE WIDTH LEFT END Aluminum YCAL 0055 Copper Center of Gravity (in.) X Y 57.9 43.0 YCAL 0055 Center of Gravity (in.) X Y 62.5 43.2 NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 6'; rear to wall – 6'; cooler end to wall – 4'0"; coil end to wall - 6'; top – no obstructions allowed; distance between adjacent units – 10'. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 6". 40 YORK INTERNATIONAL FORM 150.64-EG1 9/16" DIA MOUNTING HOLES(typ) 1 1/16" COIL END COOLER END 90 9/16" END CAP WIDTH 45 5/16" 1 1/16" 9 13/16" ORIGIN 9 13/16" TOP VIEW 18 7/16" Y X CG 5 3/16" 38" 25 3/8" B CONTROL PANEL B 28 9/16" TWO LIFTING HOLES BOTH SIDES Z 14" 15 1/16" 144 13/16" C G X YORK INTERNATIONAL FRONT VIEW 41 Dimensions - YCAL0061 (English) 6 3/4" 3 1/4" 3 15/16" 7/8" TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN 62 5/8" 61 7/8" ELECTRICAL ACCESS PANEL 9 15/16" 15 3/4" LIQUID OUT 34 11/16" 3" VICTAULIC (typ) 12 5/8" 43 1/8" 90 1/4" BASE WIDTH LEFT END Aluminum YCAL 0061 Copper Center of Gravity (in.) X Y 56.6 45.2 YCAL 0061 Center of Gravity (in.) X Y 61.8 45.8 NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 6'; rear to wall – 6'; cooler end to wall – 4'0"; coil end to wall - 6'; top – no obstructions allowed; distance between adjacent units – 10'. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 6". 42 YORK INTERNATIONAL FORM 150.64-EG1 9/16" DIA MOUNTING HOLES(typ) 1 1/16" COIL END COOLER END 90 9/16" END CAP WIDTH 43 5/16" 1 1/16" 9 13/16" ORIGIN 9 13/16" TOP VIEW 16 11/16" Y X CG 5 3/16" 38" 25 3/8" B CONTROL PANEL B 28 9/16" TWO LIFTING HOLES BOTH SIDES Z 14" 15 1/16" 144 13/16" C G X YORK INTERNATIONAL FRONT VIEW 43 Dimensions - YCAL0065 (English) 6 3/4" 3 1/4" 3 15/16" 7/8" TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN 62 5/8" 61 7/8" ELECTRICAL ACCESS PANEL 9 15/16" 15 3/4" LIQUID OUT 34 11/16" 3" VICTAULIC (typ) 12 5/8" 43 1/8" 90 1/4" BASE WIDTH LEFT END Aluminum YCAL 0065 Copper Center of Gravity (in.) X Y 59.7 44.9 YCAL 0065 Center of Gravity (in.) X Y 65.2 44.9 NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 6'; rear to wall – 6'; cooler end to wall – 4'0"; coil end to wall - 6'; top – no obstructions allowed; distance between adjacent units – 10'. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 6". 44 YORK INTERNATIONAL FORM 150.64-EG1 9/16" DIA MOUNTING HOLES(typ) 1 1/16" COIL END COOLER END 90 9/16" END CAP WIDTH 43 5/16" 1 1/16" ORIGIN 9 13/16" 9 13/16" TOP VIEW 16 11/16" Y X CG 5 3/16" 38" 25 3/8" B CONTROL PANEL B 28 9/16" TWO LIFTING HOLES BOTH SIDES Z 16" 15 1/16" 153 5/8" C G YORK INTERNATIONAL X FRONT VIEW 45 Dimensions - YCAL0041 (SI) 171 82 100 22 TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN ELECTRICAL ACCESS PANEL 1213 1192 879 252 401 LIQUID OUT 76 VICTAULIC (typ) 321 1146 2292 BASE WIDTH LEFT END Aluminum YCAL 0041 Copper Center of Gravity (in.) X Y 1513.7 1107.0 YCAL 0041 Center of Gravity (in.) X Y 1616.1 1111.1 NOTE: All dimensions are in mm unless specified otherwise. NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 2m; rear to wall – 2m; cooler end to wall – 1.2m; coil end to wall - 2m; top – no obstructions allowed; distance between adjacent units – 3m. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 152mm. 46 YORK INTERNATIONAL FORM 150.64-EG1 14 DIA MOUNTING HOLES(typ) 28 COIL END COOLER END 2301 END CAP WIDTH 1150 28 249 ORIGIN 249 TOP VIEW 554 Y X CG 135 965 CONTROL PANEL 645 B B 346 TWO LIFTING HOLES BOTH SIDES 355 383 Z 3678 C G YORK INTERNATIONAL X FRONT VIEW 47 Dimensions - YCAL0045 (SI) 171 82 100 22 TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN ELECTRICAL ACCESS PANEL 1213 1192 879 252 401 LIQUID OUT 76 VICTAULIC (typ) 321 1146 2292 BASE WIDTH LEFT END Aluminum YCAL 0045 Copper Center of Gravity (in.) X Y 1503.5 1105.5 YCAL 0045 Center of Gravity (in.) X Y 1605.9 1109.7 NOTE: All dimensions are in mm unless specified otherwise. NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 2m; rear to wall – 2m; cooler end to wall – 1.2m; coil end to wall - 2m; top – no obstructions allowed; distance between adjacent units – 3m. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 152mm. 48 YORK INTERNATIONAL FORM 150.64-EG1 14 DIA MOUNTING HOLES(typ) 28 COIL END COOLER END 2301 END CAP WIDTH 1150 28 249 ORIGIN 249 TOP VIEW 509 Y X CG 135 965 CONTROL PANEL 645 B B 346 TWO LIFTING HOLES BOTH SIDES 355 383 Z 3678 C G YORK INTERNATIONAL X FRONT VIEW 49 Dimensions - YCAL0051 (SI) 171 82 100 22 TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN ELECTRICAL ACCESS PANEL 1213 1192 879 252 401 LIQUID OUT 76 VICTAULIC (typ) 321 1146 2292 BASE WIDTH LEFT END Aluminum YCAL 0051 Copper Center of Gravity (in.) X Y 1504.6 1082.4 YCAL 0051 Center of Gravity (in.) X Y 1633.0 1090.8 NOTE: All dimensions are in mm unless specified otherwise. NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 2m; rear to wall – 2m; cooler end to wall – 1.2m; coil end to wall - 2m; top – no obstructions allowed; distance between adjacent units – 3m. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 152mm. 50 YORK INTERNATIONAL FORM 150.64-EG1 14 DIA MOUNTING HOLES(typ) 28 COIL END COOLER END 2301 END CAP WIDTH 1150 28 249 ORIGIN 249 TOP VIEW 509 Y X CG 135 965 CONTROL PANEL 645 B B 346 TWO LIFTING HOLES BOTH SIDES 355 383 Z 3678 C G YORK INTERNATIONAL X FRONT VIEW 51 Dimensions -YCAL0055 (SI) 171 82 100 22 TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN 1590 ELECTRICAL ACCESS PANEL 1572 880 252 401 LIQUID OUT 76 VICTAULIC (typ) 321 1146 2292 BASE WIDTH LEFT END Aluminum YCAL 0055 Copper Center of Gravity (in.) X Y 1470.3 1092.0 YCAL 0055 Center of Gravity (in.) X Y 1586.9 1098.3 NOTE: All dimensions are in mm unless specified otherwise. NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 2m; rear to wall – 2m; cooler end to wall – 1.2m; coil end to wall - 2m; top – no obstructions allowed; distance between adjacent units – 3m. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 152mm. 52 YORK INTERNATIONAL FORM 150.64-EG1 14 DIA MOUNTING HOLES(typ) 28 COIL END COOLER END 2301 END CAP WIDTH 1151 28 249 ORIGIN 249 TOP VIEW 468 Y X CG 131 965 645 B CONTROL PANEL B 726 TWO LIFTING HOLES BOTH SIDES 356 383 Z 3678 C G YORK INTERNATIONAL X FRONT VIEW 53 Dimensions - YCAL0061 (SI) 171 82 100 22 TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN 1590 1572 ELECTRICAL ACCESS PANEL 880 252 401 LIQUID OUT 76 VICTAULIC (typ) 321 1095 2292 BASE WIDTH LEFT END YCAL 0061 Aluminum Center of Gravity (in.) X Y 1438.0 1147.1 YCAL 0061 Copper Center of Gravity (in.) X Y 1569.3 1162.9 NOTE: All dimensions are in mm unless specified otherwise. NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 2m; rear to wall – 2m; cooler end to wall – 1.2m; coil end to wall - 2m; top – no obstructions allowed; distance between adjacent units – 3m. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 152mm. 54 YORK INTERNATIONAL FORM 150.64-EG1 14 DIA MOUNTING HOLES(typ) 28 L2 L1 COIL END COOLER END 2301 END CAP WIDTH 1100 R2 R1 249 ORIGIN 28 249 TOP VIEW 424 Y X CG 131 965 645 B CONTROL PANEL B 726 TWO LIFTING HOLES BOTH SIDES 356 383 Z 3678 C G YORK INTERNATIONAL X FRONT VIEW 55 Dimensions - YCAL0065 (SI) 171 82 100 22 TYP. VIEW B-B BOTTOM OF PANEL LIQUID IN 1590 1572 ELECTRICAL ACCESS PANEL 880 252 401 LIQUID OUT 76 VICTAULIC (typ) 321 1095 2292 BASE WIDTH LEFT END YCAL 0065 Aluminum Center of Gravity (in.) X Y 1517.6 1140.3 YCAL 0065 Copper Center of Gravity (in.) X Y 1655.5 1141.1 NOTE: All dimensions are in mm unless specified otherwise. NOTE: Placement on a level surface of free of obstructions (including snow, for winter operation) or air circulation ensures rated performance, reliable operation, and ease of maintenance. Site restrictions may compromise minimum clearances indicated below, resulting in unpredictable airflow patterns and possible diminished performance. YORK’s unit controls will optimize operation without nuisance high-pressure safety cutouts; however, the system designer must consider potential performance degradation. Recommended minimum clearances: front to wall – 2m; rear to wall – 2m; cooler end to wall – 1.2m; coil end to wall - 2m; top – no obstructions allowed; distance between adjacent units – 3m. No more than one adjacent wall may be higher than the unit. 1" nominal deflection isolators (not shown) will increase overall unit height by 152mm. 56 YORK INTERNATIONAL FORM 150.64-EG1 14 DIA MOUNTING HOLES(typ) 28 L2 L1 COIL END COOLER END 2301 END CAP WIDTH 1100 R2 R1 249 ORIGIN 28 249 TOP VIEW 424 Y X CG 131 965 645 B CONTROL PANEL B 726 TWO LIFTING HOLES BOTH SIDES 356 383 Z 3678 C G YORK INTERNATIONAL X FRONT VIEW 57 Isolator Selections ONE INCH DEFLECTION SPRING ISOLATOR CROSS-REFERENCE CIP-X- Illustration shows single spring CIP-B or CIP-C mount. Mounting may be operated 1/2" above Free & Operating Height. EQUIPMENT BASE A Dowel Pin is 3/8" dia. for CIP-A & 1/2" thereafter NOTECIP Mounts are not to be used in seismic or wind load applications. FERROUS HOUSING SIDE ACCESS INTERNAL ADJUSTMENT BOLT Turn clockwise to load spring and maintain Free & Operating Height. TYPE CIP DIMENSIONS (inches)† Size FREE & OPERATING HEIGHT NON-SKID NEOPRENE L ACOUSTICAL ISOLATION PAD (Bolting to floor is not necessary for indoor applications) CIP-B CIP-C A L 5 3/ 4 6 5/ 8 8 1/4 8 7/8 T 1/ 2 9/ 16 W SW 2 3/4 3 1/2 HCL HCW MBD SBC 7/ 16 7/ 16 6 1/2 11/2 7 1/4 13/4 3 /8 3/ 8 7 1/4 7 7/8 Free Min Ht. Ht. 61/8 5 1/4 63/4 6 3/4 †Casting dimensions may vary ±1/8" T W SBC HCL MAX BOLT DIA. - MBD Slot Width - SW HCW All springs have additional travel to solid equal to 50% of the rated deflection. BASE PLATE DIMENSIONS FOR UNITS WITH ALL POINT LOADS LESS THATN 1404 LBS (637 KG) Weight Range (lbs) Weight Range (kg) Model Number Color 239 to 384 lbs 108 to 174 kg CIP-B- Red 384 to 639 lbs 174 to 290 kg CIP-B- White 639 to 851 lbs 290 to 386 kg CIP-B- Blue 851 to 1064 lbs 386 to 483 kg CIP-B- Gray 1064 to 1404 lbs 483 to 637 kg CIP-B- Black FOR UNITS WITH ANY POINT LOAD ABOVE 1404 LBS (637 KG) 58 Weight Range (lbs) Weight Range (kg) Model Number Color Up to 851 lbs Up to 386 kg CIP-C- Black 851 to 1149 lbs 386 to 521 kg CIP-C- Yellow 1149 to 1489 lbs 521 to 675 kg CIP-C- Black 1489 to 1786 lbs 675 to 910 kg CIP-C- Yellow w/ Red 1786 to 2028 lbs 910 to 920 kg CIP-C- Yellow w/ Green 2028 to 2254 lbs 920 to 1022 kg CIP-C- Red w/ Red 2254 to 2936 lbs 1022 to 1332 kg CIP-C- Red w/ Green YORK INTERNATIONAL FORM 150.64-EG1 NEOPRENE ISOLATOR CROSS-REFERENCE ND-X "CS" Cap Screw D "MBD" Max. Bolt Dia. Steel Plate - Top & Bottom Neoprene covered to prevent corrosion BC L H W T Size ND-C ND-D ND-E D 2 9/16 3 3/ 8 4 1/ 2 H 2 3/ 4 2 3/ 4 4 3/ 4 L 5 1/ 2 6 1/ 4 7 3/ 8 ND-C ND-D ND-E 65.1 85.7 114.3 69.9 69.9 120.7 139.7 158.8 187.3 Weight Range (lbs) ENGLISH T 1/ 4 5/16 1/ 4 SI 6.4 7.9 6.4 W 2 5/16 4 5 1/80 BC 4 1/80 5 6 1/80 CS 1/2- 13 x 1” 1/2- 13 x 1” 1/2- 13 x 1” MBD 1/ 2" 1/ 2" 1/ 2" 58.7 101.6 127.3 101.9 127.0 152.7 1/2- 13 x 1” 1/2- 13 x 1” 1/2- 13 x 1” 1/ 2" 1/ 2" 1/ 2" Weight Range (kg) Model Number Color Up to 751 lbs Up to 341 kg ND-C Yellow 751 to 1651 lbs 341 to 749 kg ND-D Yellow 1651 to 3226 lbs 749 to 1463 kg ND-E Yellow YORK INTERNATIONAL 59 Isolator Details (cont'd) TWO INCH DEFLECTION, SEISMIC SPRING ISOLATOR CROSS-REFERENCE SLRS SLRS-2-C2 has 2 springs. "D" Tap - 4 Holes unless otherwise requested Vertical Limit Stops-Out of contact during normal operation E E E E H MBD -Max Bolt Diameter Rubber Snubbing Collar T HCL L HCW W Adjustment Bolt Lower Restraining Nut Non-Skid Neoprene PadInternal Enclosed Neoprene Pad can be removed if mounts are welded Steel Acoustical into position. Housing Pad SIZE T D E 3/8 5/8 1 3/8 ENGLISH ‡‡ ‡‡ H 2-C2 8 1/2 L 14 HCL W HCW MBD 12 1/4 5 1/4 3 1/ 2 5/8" SI SIZE H 2-C2 215.9 60 T D E 9.5 15.9 34.9 L HCL W 355.6 311.2 133.4 HCW MBD 88.9 5/8" *Weight Range (lbs) Weight Range (kg) Model Number Color Up to 358 lbs Up to 162 kg SLRS-2-C2- Red 358 to 443 lbs 162 to 201 kg SLRS-2-C2- White 443 to 582 lbs 201 to 264 kg SLRS-2-C2- Black 582 to 783 lbs 264 to 335 kg SLRS-2-C2- Blue 783 to 1038 lbs 335 to 471 kg SLRS-2-C2- Green 1038 to 1497 lbs 471 to 679 kg SLRS-2-C2- Gray 1497 to 2058 lbs 679 to 933 kg SLRS-2-C2- Silver 2058 to 2619 lbs 933 to 1188 kg SLRS-2-C2- Gray w/ red 2619 to 3180 lbs 1188 to 1442 kg SLRS-2-C2- Silver w/ red YORK INTERNATIONAL FORM 150.64-EG1 INTENTIONALLY LEFT BLANK YORK INTERNATIONAL 61 Electrical Data NOTES: 1. Minimum Circuit Ampacity (MCA) is based on 125% of the rated load amps for the largest motor plus 100% of the rated load amps for all other loads included in the circuit, per N.E.C. Article 430-24. If the optional Factory Mounted Control Transformer is provided, add the following MCA values to the electrical tables for the system providing power to the transformer: -17, add 2.5 amps; -28, add 2.3 amps; -40, add 1.5 amps, -46, add 1.3 amps; -58, add 1 amps. 2. The minimum recommended disconnect switch is based on 115% of the rated load amps for all loads included in the circuit, per N.E.C. Article 440. 3. Minimum fuse size is based upon 150% of the rated load amps for the largest motor plus 100% of the rated load amps for all other loads included in the circuit to avoid nuisance trips at start-up due to lock rotor amps. It is not recommended in applications where brown outs, frequent starting and stopping of the unit, and/or operation at ambient temperatures in excess of 95ºF (35ºC) is anticipated. 4. Maximum fuse size is based upon 225% of the rated load amps for the largest motor plus 100% of the rated load amps for all other loads included in the circuit, per N.E.C. Article 440-22. 5. Circuit breakers must be UL listed and CSA certified and maximum size is based on 225% of the rated load amps for the largest motor plus 100% of the rated load amps for all other loads included in the circuit. Otherwise, an HACR-type circuit breakers must be used. Maximum HACR circuit breaker rating is based on 225% of the rated load amps for the largest motor plus 100% of the rated load amps for all other loads included in the circuit. 6. The “INCOMING WIRE RANGE” is the minimum and maximum wire size that can be accommodated by the unit wiring lugs. The (2) preceding the wire range indicates the number of termination points available per phase of the wire range specified. Actual wire size and number of wires per phase must be determined based on the National Electrical Code, using copper connectors only. Field wiring must also comply with local codes. 7. A ground lug is provided for each compressor system to accommodate a field grounding conductor per N.E.C. Table 250-95. A control circuit grounding lug is also supplied. 8. The supplied disconnect is a “Disconnecting Means” as defined in the N.E.C. 100, and is intended for isolating the unit for the available power supply to perform maintenance and troubleshooting. This disconnect is not intended to be a Load Break Device. 9. Field Wiring by others which complies to the National Electrical Code & Local Codes. 62 YORK INTERNATIONAL FORM 150.64-EG1 CONTROL POWER UNIT VOLTAGE MODELS w/o CONTROL TRANS MODELS w/ CONTROL TRANS UNIT VOLTAGE 115-1-60/50 MCA NOTE A OVER CURRENT PROTECTION, SEE NOTE B NF DISC Sw MIN MAX 15A 10A 15A 30 A / 240V -17 200-1-60 15A 10A 15A 30 A / 240V -28 230-1-60 15A 10A 15A 30 A / 240V -40 380-1-60 15A 10A 15A 30 A / 480V -46 460-1-60 15A 10A 15A 30 A / 480V -50 380/415-1-60 15A 10A 15A 30A / 415V -58 575-1-60 15A 10A 15A 30 A / 600V A. Minimum #14 AWG, 75°C, Copper Recommended B. Minimum and Maximum Over Current Protection, Dual Element Fuse or Circuit Breaker VOLTAGE CODE -17 -28 -40 -46 -50 -58 LEGEND ACR-LINE C.B. D.E. DISC SW FACT MOUNT CB FLA HZ MAX MCA MIN MIN NF RLA S.P. WIRE UNIT MTD SERV SW LRA YORK INTERNATIONAL VOLTAGE RANGE UNIT POWER 200-3-60 230-3-60 380/415-3-60 460-3-60 380/415-3-50 575-3-60 MIN. 180 207 342 414 342 517 MAX. 220 253 440 506 440 633 ACROSS THE LINE START CIRCUIT BREAKER DUAL ELEMENT FUSE DISCONNECT SWITCH FACTORY MOUNTED CIRCUIT BREAKER FULL LOAD AMPS HERTZ MAXIMUM MINIMUM CIRCUIT AMPACITY MINIMUM MINIMUM NON FUSED RATED LOAD AMPS SINGLE POINT WIRING UNIT MOUNTED SERVICE (NON-FUSED DISCONNECT SWITCH) LOCKED ROTOR AMPS 63 Electrical Data - 60Hz YCAL0041 - YCAL0065 SINGLE POINT FIELD SUPPLIED POWER WIRING (See Fig. 2) (One Field Provided Power Supply to the chiller. Field connections to Factory Provided Power Terminal Block (standard), Non-Fused Disconnect Switch (optional) or Circuit Breaker (optional).) MODEL YCAL 0041 0045 0051 0055 0061 0065 D.E. FUSE MIN N/F DISC SW2 REC. MAX4 VOLT MCA1 200 197 250 225 230 184 250 380 107 150 460 90 575 71 200 CKT. BKR.5 FIELD WIRING LUGS6 TERMINAL BLOCK (std) FIELD WIRING LUGS6 NF DISC. SWITCH (opt) LUGS/ LUG WIRE RANGE PHASE REC. MAX LUGS/ PHASE LUG WIRE RANGE 225 225 225 1 6awg - 500MCM 1 6awg - 350MCM 200 200 200 200 1 6awg - 500MCM 1 6awg - 350MCM 125 125 125 125 1 6awg - 500MCM 1 6awg - 350MCM 100 100 100 100 100 1 6awg - 500MCM 1 6awg - 350MCM 100 80 80 80 80 1 6awg - 500MCM 1 6awg - 350MCM 199 250 225 225 225 225 1 6awg - 500MCM 1 6awg - 350MCM 230 186 250 200 200 200 200 1 6awg - 500MCM 1 6awg - 350MCM 380 108 150 125 125 125 125 1 6awg - 500MCM 1 6awg - 350MCM 460 91 100 100 100 100 100 1 6awg - 500MCM 1 6awg - 350MCM 575 71 100 80 80 80 80 1 6awg - 500MCM 1 6awg - 350MCM 200 228 250 250 250 250 250 1 6awg - 500MCM 2 3/0 - 250MCM 230 212 250 225 250 225 250 1 6awg - 500MCM 2 3/0 - 250MCM 380 123 150 150 150 150 150 1 6awg - 500MCM 1 6awg - 350MCM 460 103 150 110 110 110 110 1 6awg - 500MCM 1 6awg - 350MCM 575 81 100 90 90 90 90 1 6awg - 500MCM 1 6awg - 350MCM 200 250 400 300 300 300 300 1 6awg - 500MCM 2 3/0 - 250MCM 230 233 400 250 300 250 300 1 6awg - 500MCM 2 3/0 - 250MCM 380 135 150 150 150 150 150 1 6awg - 500MCM 1 6awg - 350MCM 460 113 150 125 125 125 125 1 6awg - 500MCM 1 6awg - 350MCM 575 89 100 100 100 100 100 1 6awg - 500MCM 1 6awg - 350MCM 200 274 400 300 300 300 300 1 6awg - 500MCM 1 250MCM - 500MCM 230 255 400 300 300 300 300 1 6awg - 500MCM 1 250MCM - 500MCM 380 148 200 175 175 175 175 1 6awg - 500MCM 1 6awg - 350MCM 460 125 150 150 150 150 150 1 6awg - 500MCM 1 6awg - 350MCM 575 98 150 110 110 110 110 1 6awg - 500MCM 1 6awg - 350MCM 200 292 400 350 350 350 350 1 6awg - 500MCM 1 250MCM - 500MCM 230 272 400 300 300 300 300 1 6awg - 500MCM 1 250MCM - 500MCM 380 158 200 175 175 175 175 1 6awg - 500MCM 1 6awg - 350MCM 460 132 150 150 150 150 150 1 6awg - 500MCM 1 6awg - 350MCM 575 104 150 110 125 110 125 1 6awg - 500MCM 1 6awg - 350MCM See Notes on page 100. 64 YORK INTERNATIONAL FORM 150.64-EG1 YCAL0041 - YCAL0065 SINGLE POINT FIELD SUPPLIED POWER WIRING (See Fig. 2) (One Field Provided Power Supply to the chiller. Field connections to Factory Provided Power Terminal Block (standard), Non-Fused Disconnect Switch (optional) or Circuit Breaker (optional).) FIELD WIRING LUGS6 CIRCUIT BREAKER (opt) SYSTEM #1 COMPRESSOR & FAN COMPR. #1 COMPR. #2 SYSTEM #2 COMPRESSOR & FAN FANS COMPR. #1 COMPR. #2 FANS LUGS/ PHASE LUG WIRE RANGE RLA LRA RLA LRA QTY FLA(EA) RLA LRA RLA LRA QTY FLA(EA) 1 6awg - 350MCM 39.1 250 39.1 250 2 7.6 39.1 250 39.1 250 2 7.6 1 6awg - 350MCM 36.2 250 36.2 250 2 7.4 36.2 250 36.2 250 2 7.4 1 6awg - 350MCM 20.9 155 20.9 155 2 4.5 20.9 155 20.9 155 2 4.5 1 6awg - 350MCM 17.2 125 17.2 125 2 4 17.2 125 17.2 125 2 4 1 6awg - 350MCM 13.8 100 13.8 100 2 2.9 13.8 100 13.8 100 2 2.9 1 6awg - 350MCM 40.0 250 40.0 250 2 7.6 39.1 250 39.1 250 2 7.6 1 6awg - 350MCM 37.0 250 37.0 250 2 7.4 36.2 250 36.2 250 2 7.4 1 6awg - 350MCM 21.3 155 21.3 155 2 4.5 20.9 155 20.9 155 2 4.5 1 6awg - 350MCM 17.6 125 17.6 125 2 4 17.2 125 17.2 125 2 4 1 6awg - 350MCM 14.1 100 14.1 100 2 2.9 13.8 100 13.8 100 2 2.9 2 3/0 - 250MCM 40.0 350 40.0 350 2 7.6 49.4 316 53.8 374 2 7.6 2 3/0 - 250MCM 37.0 350 37.0 350 2 7.4 45.8 316 49.8 374 2 7.4 1 6awg - 350MCM 21.3 195 21.3 195 2 4.5 26.4 199 28.7 235 2 4.5 1 6awg - 350MCM 17.6 167 17.6 167 2 4 21.8 158 23.7 187 2 4 1 6awg - 350MCM 14.1 125 14.1 125 2 2.9 17.4 126 19.0 150 2 2.9 2 3/0 - 250MCM 53.8 374 49.4 316 2 7.6 49.4 316 53.8 374 2 7.6 2 3/0 - 250MCM 49.8 374 45.8 316 2 7.4 45.8 316 49.8 374 2 7.4 1 6awg - 350MCM 28.7 235 26.4 199 2 4.5 26.4 199 28.7 235 2 4.5 1 6awg - 350MCM 23.7 187 21.8 158 2 4 21.8 158 23.7 187 2 4 1 6awg - 350MCM 19.0 150 17.4 126 2 2.9 17.4 126 19.0 150 2 2.9 1 250MCM - 500MCM 68.3 505 53.8 425 2 7.6 53.8 425 53.8 425 2 7.6 1 250MCM - 500MCM 63.3 505 49.8 425 2 7.4 49.8 425 49.8 425 2 7.4 1 6awg - 350MCM 36.5 280 28.7 239 2 4.5 28.7 239 28.7 239 2 4.5 1 6awg - 350MCM 30.1 225 23.7 198 2 4 23.7 198 23.7 198 2 4 1 6awg - 350MCM 24.1 180 19.0 148 2 2.9 19.0 148 19.0 148 2 2.9 1 250MCM - 500MCM 68.3 505 68.3 505 2 7.6 53.8 425 53.8 425 2 7.6 1 250MCM - 500MCM 63.3 505 63.3 505 2 7.4 49.8 425 49.8 425 2 7.4 1 6awg - 350MCM 36.5 280 36.5 280 2 4.5 28.7 239 28.7 239 2 4.5 1 6awg - 350MCM 30.1 225 30.1 225 2 4 23.7 198 23.7 198 2 4 1 6awg - 350MCM 24.1 180 24.1 180 2 2.9 19.0 148 19.0 148 2 2.9 YORK INTERNATIONAL 65 Electrical Data - 50Hz YCAL0041 - YCAL0065 SINGLE POINT FIELD SUPPLIED POWER WIRING (See Fig. 2) (One Field Provided Power Supply to the chiller. Field connections to Factory Provided Power Terminal Block (standard), Non-Fused Disconnect Switch (optional) or Circuit Breaker (optional).) MODEL YCAL VOLT MIN MCA1 N/F DISC SW2 D.E. FUSE CKT. BKR.5 FIELD WIRING LUGS6 FIELD WIRING LUGS6 TERMINAL BLOCK (std) NF DISC. SWITCH (opt) REC. MAX4 REC. MAX LUGS/ PHASE LUG WIRE RANGE LUGS/ PHASE LUG WIRE RANGE 0041 380/415 90 100 100 100 100 100 1 6awg - 500MCM 1 6awg - 350MCM 0045 380/415 91 100 100 100 100 100 1 6awg - 500MCM 1 6awg - 350MCM 0051 380/415 103 150 110 110 110 110 1 6awg - 500MCM 1 6awg - 350MCM 0055 380/415 113 150 125 125 125 125 1 6awg - 500MCM 1 6awg - 350MCM 0061 380/415 124 150 150 150 150 150 1 6awg - 500MCM 1 6awg - 350MCM 0065 380/415 132 150 150 150 150 150 1 6awg - 500MCM 1 6awg - 350MCM 66 YORK INTERNATIONAL FORM 150.64-EG1 YCAL0041 - YCAL0065 SINGLE POINT FIELD SUPPLIED POWER WIRING (See Fig. 2) (One Field Provided Power Supply to the chiller. Field connections to Factory Provided Power Terminal Block (standard), Non-Fused Disconnect Switch (optional) or Circuit Breaker (optional).) FIELD WIRING LUGS6 CIRCUIT BREAKER (opt) SYSTEM #1 COMPRESSOR & FAN COMPR. #1 COMPR. #2 SYSTEM #2 COMPRESSOR & FAN FANS COMPR. #1 COMPR. #2 FANS LUGS/ PHASE LUG WIRE RANGE RLA LRA RLA LRA QTY FLA (EA) RLA LRA RLA LRA QTY FLA (EA) 1 6awg - 350MCM 17.2 125 17.2 125 2 4 17.2 125 17.2 125 2 4 1 6awg - 350MCM 17.6 125 17.6 125 2 4 17.2 125 17.2 125 2 4 1 6awg - 350MCM 17.6 158 17.6 158 2 4 21.8 127 23.7 187 2 4 1 6awg - 350MCM 23.7 187 21.8 127 2 4 21.8 127 23.7 187 2 4 1 6awg - 350MCM 30.1 225 23.7 198 2 4 23.7 167 23.7 167 2 4 1 6awg - 350MCM 30.1 225 30.1 225 2 4 23.7 198 23.7 198 2 4 YORK INTERNATIONAL 67 Power Wiring 68 FIG. 1 – STANDARD POWER SUPPLY WIRING – (YCAL 0014 - 0080) YORK INTERNATIONAL FORM 150.64-EG1 ) YORK INTERNATIONAL 69 70 YORK INTERNATIONAL FORM 150.64-EG1 Control Wiring FLOW SW REMOTE START/STOP 13 14 13 PWM INPUT 20 13 LOAD LIMIT INPUT 21 CTB1 * * Factory wired with optional transformer. LD03611 YORK INTERNATIONAL 71 Application Data UNIT LOCATION The YCAL chillers are designed for outdoor installation. When selecting a site for installation, be guided by the following conditions: for special installation requirements. Roof installations should incorporate the use of spring-type isolators to minimize the transmission of vibration into the building structure. 1. For outdoor locations of the unit, select a place having an adequate supply of fresh air for the condenser. GROUND LEVEL INSTALLATIONS – It is important that the units be installed on a substantial base that will not settle, causing strain on the liquid lines and resulting in possible leaks. A one-piece concrete slab with footers extending below the frost line is highly recommended. Additionally, the slab should not be tied to the main building foundation, as noises will telegraph. 2. Avoid locations beneath windows or between structures where normal operating sounds may be objectionable. 3. Installation sites may be either on a roof, or at ground level. (See FOUNDATION.) 4. The condenser fans are the propeller-type, and are not recommended for use with duct work in the condenser air stream. 5. When it is desirable to surround the unit(s), it is recommended that the screening be able to pass the required chiller CFM without exceeding 0.1” of water external static pressure. 6. Protection against corrosive environments is available by supplying the units with either copper fin, cured epoxy-dipped, or epoxy-coated fins on the condenser coils. The epoxy-dipped or epoxy-coated coils should be offered with any units being installed at the seashore or where salt spray may hit the unit. In installations where winter operation is intended and snow accumulations are expected, additional height must be provided to ensure normal condenser air flow. Recommended clearances for units are given in DIMENSIONS. When the available space is less, the unit(s) must be equipped with the discharge pressure transducer option to permit high pressure unloading in the event that air recirculation were to occur. FOUNDATION The unit should be mounted on a flat and level foundation, ground or roof, capable of supporting the entire operating weight of the equipment. Operating weights are given in the PHYSICAL DATA tables. ROOF LOCATIONS – Choose a spot with adequate structural strength to safely support the entire weight of the unit and service personnel. Care must be taken not to damage the roof during installation. If the roof is “bonded”, consult the building contractor or architect 72 Mounting holes (11/16” diameter) are provided in the steel channel for bolting the unit to its foundation. See DIMENSIONS. For ground level installations, precautions should be taken to protect the unit from tampering by or injury to unauthorized persons. Screws on access panels will prevent casual tampering; however, further safety precautions, such as unit enclosure options, a fenced-in enclosure, or locking devices on the panels may be advisable. Check local authorities for safety regulations. CHILLED LIQUID PIPING The chilled liquid piping system should be laid out so that the circulating pump discharges into the cooler. The inlet and outlet cooler liquid connections are given in DIMENSIONS. Hand stop valves are recommended for use in all lines to facilitate servicing. Drain connections should be provided at all low points to permit complete drainage of the cooler and system piping. Additionally, a strainer (40 mesh) is recommended for use on the INLET line to the cooler. Pressure gauge connections are recommended for installation in the inlet and outlet water lines. Gauges are not furnished with the unit and are to be furnished by other suppliers. The chilled liquid lines that are exposed to outdoor ambients should be wrapped with a supplemental heater cable and covered with insulation. As an alternative, ethylene glycol should be added to protect against freezeup during low ambient periods. A flow switch is available as an accessory on all units. The flow switch (or its equivalent) must be installed in the leaving water piping of the cooler and must not be YORK INTERNATIONAL FORM 150.64-EG1 Typical Piping for Brazed-Plate Coolers Notes: 1. Placement on a level surface free of obstructions (including snow, for winter operation) or air recirculation ensures rated performance, reliable operation and ease of maintenance. 2. Piping and wiring shown is for reference use only and is not in accordance with any national or local standards. 3. All wiring and piping must comply with applicable local and national codes. 4. All wiring and piping must follow standard piping techniques as discussed in the ASHRAE handbook. 5. A strainer with a mesh size between .5 and 1.5 mm is recommended upstream of the heat exchanger to prevent clogging. Vibration Eliminators Vent Strainer INLET Isolation Valves Flow Switch Pressure Gauge Shut Off Valves OUTLET Drain Vibration Eliminators YORK INTERNATIONAL 73 Guide Specifications PART 1 – GENERAL 1.01 SCOPE A. The requirements of the General Conditions, Supplementary Conditions, Division 1, and Drawings apply to all Work herein. workmanship and material for a period of one year from date of initial start-up or eighteen (18) months from date of shipment, whichever occurs first. 1.03 DELIVERY AND HANDLING A. Unit shall be delivered to job site fully assembled, and charged with refrigerant and oil by the Manufacturer. (Contractor is responsible for providing and installing the refrigerant charge including the charge required for the field installed interconnecting piping. Chiller components shall ship with a dry nitrogen holding charge – Remote Evaporator option). B. Provide Microprocessor controlled, multiple-scroll compressor, air-cooled, liquid chillers of the scheduled capacities as shown and indicated on the Drawings, including but not limited to: 1. Chiller package 2. Electrical power and control connections 3. Chilled water connections 4. Change of refrigerant oil (for factory mounted evaporator) or (evaporator shipped separately for field installation and piping by contractor) PART 2 - PRODUCTS 1.02 2.01 QUALITY ASSURANCE A. Products shall be Designed, Tested, Rated and Certified in accordance with, and installed in compliance with applicable sections of the following Standards and Codes: 1. ANSI/ASHRAE Standard 15 – Safety Code for Mechanical Refrigeration 2. ASHRAE 90.1– Energy Efficiency compli ance. 3. ANSI/NFPA Standard 70 – National Electrical Code (N.E.C.). 4. ASME Boiler & Pressure Vessel Code, Sec tion VIII, Division 1. 5. ARI Standard 550/590 – Positive Displacement Compressors and Air Cooled Rotary Screw Water-Chilling Packages. 6. Conform to Intertek Testing Services, formerly ETL, for construction of chillers and provide ETL/cETL Listing label. 7. Manufactured in facility registered to ISO 9002. 8. OSHA - Occupational Safety and Health Act B. Factory Test: Chiller shall be pressure-tested, evacuated and fully charged with refrigerant and oil, and shall be factory operational run tested with water flowing through the vessel. C. Chiller manufacturer shall have a factory trained and supported service organization that is within a 50 mile radius of the site. D. Warranty: Manufacturer shall Warrant all equipment and material of its manufacture against defects in 74 B. Unit shall be stored and handled per Manufacturer’s instructions. CHILLER MATERIALS AND COMPONENTS A. General: Install and commission, as shown on the schedules and plans, factory assembled, charged, and tested air cooled scroll compressor chiller(s) as specified herein. Chiller shall be designed, selected, and constructed using a refrigerant with Flammability rating of “1”, as defined by ANSI/ASHRAE STANDARD - 34 Number Designation and Safety Classification of Refrigerants. Chiller shall include, but is not limited to: a complete system with a single refrigerant circuit 35 tons (123kW) and below, and not less than two refrigerant circuits above 35 tons (123kW), scroll compressors, direct expansion type evaporator, air-cooled condenser, refrigerant, lubrication system, interconnecting wiring, safety and operating controls including capacity controller, control center, motor starting components, and special features as specified herein or required for safe, automatic operation. B. Cabinet: External structural members shall be constructed of heavy gauge, galvanized steel coated with baked on powder paint which, when subject to ASTM B117, 1000 hour, 5% salt spray test, yields minimum ASTM 1654 rating of “6”. Add Wire Panels of heavy gauge, welded wire-mesh, coated to resist corrosion, to protect condenser coils from incidental damage and restrict unauthorized access to internal components. Factory installed. 2.02 COMPRESSORS Compressors: Shall be hermetic, scroll-type, including: 1. Compliant design for axial and radial sealing YORK INTERNATIONAL FORM 150.64-EG1 2. Refrigerant flow through the compressor with 100% suction cooled motor. 3. Large suction side free volume and oil sump to provide liquid handling capability. 4. Compressor crankcase heaters to provide extra liquid migration protection. 5. Annular discharge check valve and reverse vent assembly to provide low pressure drop, silent shutdown and reverse rotation protection. 6. Initial Oil charge. 7. Oil Level sightglass. 8. Vibration isolator mounts for compressors. 9. Brazed-type connections for fully hermetic refrigerant circuits. 2.03 REFRIGERANT CIRCUIT COMPONENTS Each refrigerant circuit shall include: liquid line shutoff valve with charging port, low side pressure relief device, filter-drier, solenoid valve, sight glass with moisture indicator, expansion valves, and flexible, closed-cell foam insulated suction line. 2.04 HEAT EXCHANGERS A. Evaporator: 1. Evaporator shall be brazed-plate stainless steel construction, single or dual circuit heat exchangers capable of refrigerant working pressure of 450 psig (3103 kPa) and liquid side pressure of 150 psig (1034 kPa) (Option for 300 psig [2068 kPa] available.) 2. Evaporator shall be covered in 3/4" (19mm) flexible, closed cell insulation, thermal conduc tivity of 0.26k (BTU/HR-FT2-°F]/in.) maximum. 3. C o o l e r s h a l l h a v e t h e r m o s t a t i cally controlled heaters to protect to -20°F (29°C) ambient in off-cycle. 4. Brazed plate heat exchangers shall be UL listed. 5. Installing contractor must include accomoda tions in the chilled water piping to allow prop er drainage and venting of the heat exchang er. A strainer with a mesh size between 0.5 and 1.5mm (40 mesh) is recommended up stream of the heat exchanger to prevent clog ging. B. Air Cooled Condenser: 1. Coils: Internally enhanced, seamless copper tubes, mechanically expanded into aluminum alloy fins with full height collars. Subcooling coil an integral part of condenser. Design working pressure shall be 450 PSIG (31 bar). YORK INTERNATIONAL 2. Low Noise Fans: Shall be dynamically and statically bal anced, direct drive, corrosion re sistant glass fiber reinforced composite blades molded into a low noise, full-airfoil cross section, providing vertical air discharge and low sound. Each fan in its own compartment to prevent crossflow during fan cycling. Guards of heavy gauge, PVC (polyvinylchloride) coated or galvanized steel. 3. 2.05 Fan Motors: High efficiency, direct drive, 6 pole, 3 phase, insulation class “F”, current protected, Totally Enclosed Air-Over (TEAO), rigid mounted, with double sealed, permanently lubricated, ball bearings. CONTROLS A. General: Automatic start, stop, operating, and protection sequences across the range of scheduled conditions and transients. B. Microprocessor Enclosure: Rain and dust tight NEMA 3R/12 (IP55) powder painted steel cabinet with hinged, latched, and gasket sealed door. C. Microprocessor Control Center: 1. Automatic control of compressor start/stop, anti-coincidence and anti-recycle timers, automatic pumpdown on shutdown, condenser fans, evaporator pump, evaporator heater, unit alarm contacts, and chiller operation from 0°F to 125°F (-18°C to 52°C) ambient. Automatic reset to normal chiller operation after power failure. 2. Remote water temperature reset via a Pulse Width Modulated (PWM) input signal or up to two steps of demand (load) limiting. 3. Software stored in non-volatile memory, with programmed setpoints retained in lithium battery backed real time clock (RTC) memory for minimum 5 years. 4. Forty character liquid crystal display, descriptions in English (or Spanish, French, Italian, or German), numeric data in English (or Metric) units. Sealed keypad with sections for Setpoints, Display/Print, Entry, Unit Options & clock, and On/Off Switch. 5. Programmable Setpoints (within Manufacturer limits): display language; chilled liquid temperature setpoint and range, remote reset temperature range, set daily schedule/holiday for start/ stop, manual override for servicing, low and high ambient cutouts, number of compressors, low 75 6. 7. 8. 9. liquid temperature cutout, low suction pressure cutout, high discharge pressure cutout, anti-recycle timer (compressor start cycle time), and anti-coincident timer (delay compressor starts). Display Data: Return and leaving liquid temperatures, low leaving liquid temperature cutout setting, low ambient temperature cutout setting, outdoor air temperature, English or metric data, suction pressure cutout setting, each system suction pressure,discharge pressure (standard on YCAL0041-0065 models), liquid temperature reset via a YORK ISN DDC or Building Automation System (by others) via PWM input as standard or a 4-20milliamp or 010 VDC input or contact closure with optional BAS interface, anti-recycle timer status for each compressor, anti-coincident system start timer condition, compressor run status, no cooling load condition, day, date and time, daily start/ stop times, holiday status, automatic or manual system lead/lag control, lead system definition, compressor starts/operating hours (each), status of hot gas valves, evaporator heater and fan operation, run permissive status, number of compressors running, liquid solenoid valve status, load & unload timer status, water pump status. System Safeties: Shall cause individual com pressor systems to perform auto shut down; manual reset required after the third trip in 90 minutes. Includes: high discharge pressure, low suction pressure, high pressure switch, and motor protector. Compressor motor protector shall protect against damage due to high input current or thermal overload of windings. Unit Safeties: Shall be automatic reset and cause compressors to shut down if low ambient, low leaving chilled liquid temperature, under voltage, and flow switch operation. Contractor shall provide flow switch and wiring per chiller manufacturer requirements. Alarm Contacts: Low ambient, low leaving chilled liquid temperature, low voltage, low battery, and (per compressor circuit): high discharge pressure, and low suction pressure. D. Manufacturer shall provide any controls not listed above, necessary for automatic chiller operation. Mechanical Contractor shall provide field control wiring necessary to interface sensors to the chiller control system. 2.06 P O W E R C O N N E C T I O N A N D D I S T R IBUTION 76 A. Power Panels: 1. NEMA 3R/12 (IP55) rain/dust tight, powder painted steel cabinets with hinged, latched, and gasket sealed outer doors. Provide main power connection(s), control power connections, compressor and fan motor start contactors, current overloads, and factory wiring. 2. Power supply shall enter unit at a single location, be 3 phase of scheduled voltage, and connect to individual terminal blocks per compressor. Separate disconnecting means and/ or external branch circuit protection (by Contractor) required per applicable local or national codes. B. Exposed compressor, control and fan motor power wiring shall be routed through liquid tight conduit. 2.07 ACCESSORIES AND OPTIONS Some accessories and options supercede standard product features. Your YORK representative will be pleased to provide assistance. A. Microprocessor controlled, Factory installed Acrossthe-Line type compressor motor starters as standard. B. Outdoor Ambient Temperature Control 1. Low Ambient Control: Permits unit operation to 0°F ambient. . 2. High Ambient Control: Permits unit operation above 115°F ambient. C. Power Supply Connections: 1. Single Point Power Supply: Single point Terminal Block for field connection and interconnecting wiring to the compressors. Separate external protection must be supplied, by others, in the incoming power wiring, which must comply with the National Electric Code and/or local codes. Standard unit controls to 25°F ambient. Low Ambient Control standard on YCAL0041-0065 models 2. Single Point Power Supply with individual System Breakers: Single or Terminal Block(s) for field connection and factory interconnecting wiring to factory supplied system breakers . Available on YCAL0090-0134 models. 3. Single Point or Disconnect: Single or Dual point Non-Fused Disconnect(s) and lockable external handle (in compliance with Article 440-14 YORK INTERNATIONAL FORM 150.64-EG1 of N.E.C.) can be supplied to isolate the unit power voltage for servicing. Separate external fusing must be supplied, by others, in the in coming power wiring, which must comply with the National Electric Code and/or local codes. 4. Single Point Disconnect with Individual System Breakers: Single point Terminal Block with NonFused Disconnect and lockable external handle (in compliance with Article 440-14 of N.E.C.) can be supplied to isolate power voltage for servicing. Factory interconnecting wiring from disconnect to factory supplied circuit breakers. Available on YCAL0041-0065. 5. Single Point Circuit Breaker: Single point Terminal Block with Circuit Breaker and lockable external handle (in compliance with Article 440 14 of N.E.C.) can be supplied to isolate power voltage for servicing. Incoming power wiring must comply with the National Electric Code and/or local codes. Single Point Circuit Break ers available on YCAL0041-0065 models. D. Pressure Transducers and Readout Capability 1. Discharge Pressure Transducers: Permits unit to sense and display discharge pressure. Standard on YCAL0080-0134 models. E. Control Power Transformer: Converts unit power voltage to 120-1-60 (500 VA capacity). Factorymounting includes primary and secondary wiring between the transformer and the control panel. F. Motor Current Module: Capable of monitoring compressor motor current. Provides extra protection against compressor reverse rotation, phase-loss and phase imbalance. Option consists of one module per electrical system. (Factory-mounted.) G. Power Factor Correction Capacitors: Provided to correct unit compressor factors to a 0.90-0.95. H. Condenser Coil Environmental Protection: 1. Pre-Coated: Epoxy coated aluminum fin stock to guard from corrosive agents and insulate against galvanic potential. For mild seashore or industrial locations. 2. Copper Fin: Provide copper fins in lieu of aluminum. 3. Post-Coated Dipped: Dipped-cured coating on condenser coils for seashore and other corrosive applications (with the exception of strong alkalis, oxidizers, and wet bromine, chlorine and fluorine in concentrations greater than YORK INTERNATIONAL 100ppm). I. Protective Chiller Panels (Factory or Field Mounted 1. Louvered Panels (condenser coils only): Painted steel as per remainder of unit cabinet, over external condenser coil faces. 2. Wire Panels (full unit): Heavy gauge, welded wire-mesh, PVC -coated to resist corrosion, to protect condenser coils from incidental damage and restrict unauthorized access to internal components. 3. Louvered Panels (full unit): Painted steel as per remainder of unit cabinet, to protect condenser coils from incidental damage, visually screen internal components, and prevent unauthorized access to internal components. 4. Louvered/Wire Panels: Louvered steel panels on external condenser coil faces, painted as per remainder of unit cabinet. Heavy gauge, welded wire-mesh, coated to resist corrosion, around base of machine to restrict unauthorized access. J. Flow Switch (Field-mounted): Vapor proof SPDT, NEMA 4X switch ( ___150 PSIG or ___300 PSIG), -20°F to 250°F. K. Differential Pressure Switch: Alternative to an above mentioned flow switch. Pretempco model DPS300A-P40PF-82582-5 (300 psi max. working pressure) SPDT 5 amp 125/250VAC switch, Range 0 - 40 PSID, deadband 0.5 - 0.8 psi, with 1/4” NPTE Pressure Connections. L. Evaporator options: 1. Provide 1½" cooler insulation in lieu of standard ¾". 2. Provide DX Cooler with 300 PSIG water-side design working pressure in lieu of standard 150 PSIG. 3. Provide Raised Face Flanges for field installation on cooler nozzles and field piping: a. 150 PSIG, welded Flanges. b. 300 PSIG, welded Flanges. M. Service Isolation valves: Service suction and dis charge (ball type) isolation valves are added to unit per system. This option also includes a system high pressure relief valve in compliance with ASHRAE 15. (Factory-mounted.) N. Remote Cooler: Manufacturer shall provide separately: chiller less evaporator, leaving and return 77 water sensors, and liquid line components (solenoid valves, filter driers, sight glasses, and TXVs), as discrete elements of a complete factory system. Contractor shall be field erect system and provide interconnecting refrigerant piping and wiring in accordance with Manufacturer recommendations, and project plans and schedules. Where not otherwise specified, Contractor provided system piping shall be in accordance with applicable sections of ASHRAE Handbook. O. Hot Gas By-Pass: Permits continuous, stable operation at capacities below the minimum step of unloading to as low as 5% capacity (depending on both the unit & operating conditions) by introducing an artificial load on the cooler. Hot gas by-pass is installed on only one refrigerant circuit (System #1). P. Microprocessor Membrane Keypad Graphics on in lieu of Standard English: 1. 2. 3. 4. French language. German language. Spanish language. Italian language. Q. Thermal Storage: Leaving chilled liquid setpoint range for charge cycle from 25°F to 20°F minimum, with automatic reset of the leaving brine temperature up to 40°F above the setpoint. (Works with Option T) R. Low Temperature Process Brine: Leaving chilled liquid setpoint range 20°F to 30°F. S. Chicago Code Relief Valves to meet Chicago Code requirements. T. Building Automation System (EMS) Reset Interface: Chiller to accept 4 to 20mA, 0 to 10 VDC, or discrete contact closure input to reset the leaving chilled liquid temperature. U. Remote Control Panel (Field-mounted): Auxiliary panel for remote user interface for functions normally made at the unit control center. Available on YCAL0014-0080 models. V. OptiView Remote Control Panel (Field-mounted): Graphical interface panel to remotely control and monitor up to 8 different units. on mixed liquid temperature. X. Sound Reduction (Factory-mounted): 1. Ultra quiet, low speed, reduced noise fans 2. Compressor Acoustic Sound Blankets Y. Vibration Isolation (Field-mounted): 1. Neoprene Pad Isolators. 2. 1 Inch Deflection Spring Isolators: Level adjustable, spring and cage type isolators for mounting under the unit base rails. 3. 2 Inch Deflection Seismic Isolators: Level adjustable, restrained mounts in rugged welded steel housing with vertical and horizontal limit stops. Housings shall be designed to withstand a minimum 1.0g accelerated force in all directions to 2 inches. PART 3 - EXECUTION 3.01 INSTALLATION A. General: Rig and Install in full accordance with Manufacturers requirements, Project drawings, and Contract documents. B. Location: Locate chiller as indicated on drawings, including cleaning and service maintenance clearance per Manufacturer instructions. Adjust and level chiller on support structure. If equipment provided exceeds height of scheduled chiller, installing contractor is responsible for additional costs associated with extending the height of parapet or screening walls/enclosures C. Components: Installing Contractor shall provide and install all auxiliary devices and accessories for fully operational chiller. D. Electrical: Coordinate electrical requirements and connections for all power feeds with Electrical Contractor (Division 16). E. Controls: Coordinate all control requirements and connections with Controls Contractor. F. Finish: Installing Contractor shall paint damaged and abraded factory finish with touch-up paint matching factory finish. W. Multi-Unit Sequencing Panel (Field-mounted): Separate Sequencing control center is provided to permit control of up to eight chillers in parallel based 78 YORK INTERNATIONAL FORM 150.64-EG1 YORK INTERNATIONAL 79 P.O.Box 1592 York, Pennsylvania USA 17405-1592 Copyright © by York International Corporation 2004 Form 150.62-EG1 (103) Supersedes: 150.62-EG1 (102) Subject to change without notice. Printed in the USA ALL RIGHTS RESERVED RPC 3M 303 9.28 Codes: DXL, ET2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-701 About : uuid:8879e121-f4e1-4c97-a428-e97ca5ccc8a2 Create Date : 2005:05:02 09:46:08Z Modify Date : 2005:05:03 17:18:08-04:00 Metadata Date : 2005:05:03 17:18:08-04:00 Creator Tool : Adobe InDesign CS (3.0.1) Version ID : 1 Rendition Class : proof:pdf Document ID : adobe:docid:indd:3d2913e2-bb08-11d9-b261-cd3dc593bae1 Instance ID : uuid:78449dd5-5845-42bd-af8d-f3b0e7f5d487 Derived From Instance ID : 3d2913e1-bb08-11d9-b261-cd3dc593bae1 Derived From Document ID : adobe:docid:indd:3d2913e0-bb08-11d9-b261-cd3dc593bae1 Derived From Version ID : 1 Format : application/pdf Title : Air-cooled Scroll Chiller (Style D) Model YCAL0041–YCAL0065 (47–60 TON) R-22 (50 & 60HZ) Description : Air-cooled Scroll Chiller (Style D) Model YCAL0041–YCAL0065 (47–60 TON) R-22 (50 & 60HZ) Creator : York International 2005 Subject : Air-cooled Scroll Chiller (Style D) Model YCAL0041–YCAL0065 (47–60 TON) R-22 (50 & 60HZ) Producer : Adobe PDF Library 6.0 Trapped : False Keywords : Air-cooled Scroll Chiller (Style D) Model YCAL0041–YCAL0065 (47–60 TON) R-22 (50 & 60HZ) Page Count : 80 Page Layout : SinglePage Author : York International 2005EXIF Metadata provided by EXIF.tools