FAN COIL AIR CONDITIONERS INSTALLATION, OPERATION, & MAINTENANCE Supersedes: Form 115.20-NOM2 (1199) Form 115.20-NOM2 (105) 00168VIP 00172VIP MODEL YCHBC – Ceiling Cabinet Model MODEL YHBC – Ceiling Concealed Model 00173VIP 00170VIP MODEL YHH – Ceiling Concealed Model with Electric Heat MODEL YRHBC – Telescoping / Recessed Ceiling Model 00171VIP MODEL YPHBC – Ceiling Concealed Model with Insulated Return. Plenum and Filter 00174VIP MODEL YHYB – High Capacity Ceiling Concealed Model MODEL YPHH – Ceiling Concealed Model with Electric Heat, Insulated Return Plenum and Filter 00175VIP MODEL YPHYB – High Capacity Ceiling Concealed Model with Insulated Return Plenum and Filter Notes: 1. 2-Pipe units have one water coil. 4-Pipe units have two water coils. 2. Changeover is used to select heating or cooling mode. 3. YORK International does not recommend “fan cycle” applications for cooling on unit mounted thermostats. 4. For proper operation, control valve must be normally closed. 5. Aquastats provided where required. 6. Electric Heat is only available in the YHH and YPHH units. These units require a remote thermostat (low voltage 4 wire thermostat). ***** WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non authorized factory parts voids all warranty or implied warranty and may result in adverse operational performance and/or a possible hazardous safety condition to service personnel and occupants. Company employees and/or contractors are not authorized to waive this warning. L23952Y 1-05 FORM 115.20-NOM2 (105) TABLE OF CONTENTS RECEIVING..........................................................................................................................................................3 STORAGE............................................................................................................................................................3 PREPARE CEILING FOR MOUNTING................................................................................................................3 WIRING ...............................................................................................................................................................3 PIPING .................................................................................................................................................................6 DRAIN PIPING .....................................................................................................................................................7 DRAWINGS...................................................................................................................................................8 - 14 STARTUP...........................................................................................................................................................15 MAINTENANCE .................................................................................................................................................16 Reference Documents: • IOM for YVC-YVF-YVS • IOM for YSHW, YSHX • IOM for YSVW, YSVX • Parts List Form 115.20-NOM3 (Latest) Form115.22-NOM5 (Latest) Form 115.22-NOM2(Latest) Form 115.20-RP2(Latest) These documents can be ordered through Publications Dept. or downloaded @ http://intranet.york.com/web0003/library/default.asp NOTE: Use direction of airflow for selecting right- and left-hand units. TABLE 1 - NOMINAL AIRFLOWS 2 UNIT SIZE CFM 3 300 4 400 5 500 6 600 8 800 10 1000 12 1200 13 1300 16 1600 20 2000 PLENUM (OPTIONAL) LD04775 FIG. 1 – DETERMINATION OF RIGHT-HAND / LEFT-HAND REFERENCES YORK INTERNATIONAL FORM 115.20-NOM2 (105) INSTALLATION RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspection of all cartons should be made immediately. Any evidence of rough handling or apparent damage should be noted on the delivery receipt and the material inspected in the presence of the carrier's representative. If damage is found, a claim should be filed against the carrier immediately. In free (non-ducted return air) return installations of YHBC, YHH, YHHS and YHYB units; the furred down area must be completely sealed (except return air grille) to ensure that all return air is pulled from the conditioned space and not from other areas of the building structure. Access must be provided for servicing the unit. If this access is provided by a removable ceiling panel, ample space must be allowed for removal of the blower panel and to provide access to electrical and plumbing controls. Unit must not be operated during building construction due to excessive airborne dust and debris. The units must not be operated under any circumstances without an air filter in place. STORAGE If the equipment is not to be immediately installed, store it in a dry location with the motor protected against moisture, dust, corrosion and physical damage. PREPARE CEILING FOR MOUNTING Depending upon building construction, provisions for mounting the unit must be made by the contractor according to architects; drawings. It is important to ensure that the fan coils are securely mounted and the structure is sufficient to support the weight of the equipment. All anchors for mounting the equipment must be placed and sized to ensure a safe and durable installation. The YHBC, YPHBC, YRHBC, YHH, YHHS, YPHH, YHYB, and YPHYB units are designed for installation in a horizontal position above a dropped ceiling. The YCHBC is a cabinet unit intended for horizontal exposed surface mounting. YORK INTERNATIONAL WIRING All wiring must comply with the local and national code requirements. Units are provided with wiring diagrams and nameplate data to provide information required for necessary field wiring. For power wiring a 4 x 4 electrical box is provided on the cabinet for connection of power supply and is located on the same side as piping. On YHBC units, the box is shipped unattached, it is field attached to the unit in a location convenient to electrical entrance. Any devices such as fan switches or thermostats that have been furnished by the factory for field installation must be wired in strict accordance with the wiring diagram that is supplied with the unit. Failure to do so could result in damage or injury. 3 FORM 115.20-NOM2 (105) INSTALLATION ��� ����� ����� � ��� ���������� ����� �� �������� � � � � � � � � ��� �������� ����� ����������� ��� ����� � � ����� ������ � � ����� ������ � � � ���� � � � ����� ��� ����� ����� ����� ����� �������� ������������ �������� ����� ������ �������� ���� ��� ��� ��� ��� ��� ��� ��� ��� � � � ����� ��� ����� ��� ��� ��� ��� � � � ����� ��� ����� ����� ������ � � � ����� ��� ����� ��� ��� ����� ������ � � � ���� ����� ����� � ��� LD010198 ������ �� ������ ����� ���� ��� � ������ ��� � �� ����� ��� � ��� ����� ��� � �� ����� �� ����������� �� �� �� �� ������ ���������� ������� ������ ����� ������ �� ��� ��� ������ ����� ����� FIG. 2 – HORIZONTAL UNITS - TYPICAL WIRING 4 YORK INTERNATIONAL FORM 115.20-NOM2 (105) INSTALLATION T334 THERMOSTAT Heat-Off Cool, Fan Auto-On, 24V, Manual changeover, 4-Wire Thermostat (R, G, Y, W) Adj. Heat Anticipator, Fixed Cooling Anticipator, Fan Cycling (Cooling) or (Heating/Cooling), No Heating Required. T404 THERMOSTAT Heat-Off Cool, Fan Auto-On, 24V, Manual changeover, 6-Wire Thermostat (R, G, O, Y, W, B) Adj. Heat / Fixed Cool Anticipator, Fixed Cooling Anticipator, Fan Cycling. (O & B can be used for cool and heat relays respectively, or for cool & heat water valves.) T200 THERMOSTAT OPTION (W/CONTROLLER) Heat-Off Cool, Fan -On, 24V, Manual changeover, 7-Wire Thermostat (R, C, Hi, Med, Lo, 24V Heat, 24V Coil), Auto fan speed control, digital readout, auto-overide. ���������� ��������� �������� ���������� ��� ���� ����� ���������� ������ ��� ���� ����� ���� ������ ��� � � ���� ��� ���������� ��� ����� � ���� ���� ��� ������ ����� ����� ����� ������ ��� � ���� � ���� � ���� ��� � ���� ������� ��� ���� ������� � ���� ����� LD010200 LD010200 FIG. 3 – WIRING SCHEMATIC FOR HBC/PHBC/CHBC/RHBC/HYB/PHYB YORK INTERNATIONAL 5 FORM 115.20-NOM2 (105) INSTALLATION These units are provided with six (6) mounting holes (see drawings for details). Metal washers and nuts of the proper size are to be provided by the installer. When necessary, use shims to obtain the proper level. This will ensure that the condensate will drain from the unit. PIPING These units employ a hydronic coil designed for use with either hot or chilled water. All piping must be adequately sized to meet the design water flow requirements as specified for the specific installation. Piping must be installed in accordance with all applicable codes. PIPE SIZES All models except YHYB/YPHYB: • HW/CW coils are 3/8" OD tubing. • Tubing connections are 5/8" OD. Models YHYB/YPHYB: • HW/CW coils are 1/2" OD tubing. • Tubing connections are 7/8" OD. Manual air vents are provided standard on all coils All chilled water piping must be insulated to prevent condensation. Prior to connecting to the fan coil, all external piping must be purged of debris. When connecting piping or valve kits to fan coil units, do not bend or reposition the coil header tubing for alignment purposes. This could cause a tubing fracture resulting in a water leak when water pressure is applied to the system. PRECAUTIONS 1. Flush all field piping prior to connection to remove all debris. 2. Use wet cotton rags to cool valve bodies when soldering. 6 3. Open all valves (mid-way for hand valves, manually open on motorized valves) prior to soldering. 4. When soldering to bronze or brass, heat the piping while in the socket/cup and begin introducing the solder when the flux boils rapidly. Avoid direct flame into the solder joint. 5. Heat can only be applied to the cup of the valve body for a minimal time before damage occurs (even with the use of wet rags. 6. Avoid rapid quenching of solder joints, as this will produce joints of inferior quality. 7. The valve package will not support the weight of the connecting pipes. All pipes, which are connected to the units, must be completely supported prior to connection to the unit. 8. Provisions must be made for expansion and contraction of piping systems. All horizontal and vertical risers, including runouts, must be able to withstand significant movement with temperature changes. Failure to do so will result in damage and failure of piping, fittings and valves throughout the building. 9. Never insulate the heads or motorized portion of control valves. Damage can occur in the form of excessive heat build up and interference to the operation and moving parts will result. 10. All piping made in the field should be installed with consideration of additional space for any electrical routing that may be required. 11. Hydronic systems are not designed to hold pressurized air and should only be tested with water. After the system has been proven leak free, all lines and valve control packages must be insulated as specified on the building plans. Many valve packages will not physically allow all components to fit over an auxiliary drain pan. It is the installers responsibility to ensure adequate condensation prevention. The installer must also ensure that there is no condensate drippage onto electrical components beneath insulated components. YORK INTERNATIONAL FORM 115.20-NOM2 (105) INSTALLATION VALVE CLUSTER 2-Way Motorized Valve Assemblies 1. The motorized valve assembly should be attached to the supply header, which is the connection nearest the air outlet flange on the unit. 2. Prior to soldering the joints, operate all the hand valves to ensure that the handles will fully open and close without interference to other valves, ceiling, wall, plenum or other accessories. 3. All valves will operate at any angle with the exception of the motorized valve, which must be installed with the power head above horizontal. The actuator box requires a 3/4" clearance for removal. 00186VIP FIG. 4 – 2 WAY MOTORIZED VALVE ASSEMBLY 3-Way Motorized Valve Assembly 1. The 3-way valve assemblies will mount to the coil in only one position. On four-pipe right hand systems, a "B" valve assembly is required for the chilled water connection and an "A" valve assembly is required for the hot water connection. On left hand systems, an "A" valve assembly is required for the chilled water connection and the hot water connection. (See figure 4.) 2. Prior to soldering the joints, operate all the hand valves to ensure that the handles will fully open and close without interference to other valves, ceiling, wall, plenum or other accessories. 3. All valves will operate at any angle with the exception of the motorized valve, which must be installed with the power head above horizontal. The actuator box requires a 3/4" clearance for removal. YORK INTERNATIONAL 00187VIP FIG. 5 – 3 WAY MOTORIZED VALVE ASSEMBLY DRAIN PIPING Condensate drain lines must be installed with adequate slope away from the unit to assure positive drainage. YRHBC and YCHBC fan coil units require a minimum trap of 1-1/2 inches be provided in the drain line to assure proper drainage. YHBC, YPHBC, YHH, YPHH, YHYB, and YPHYB fan coil units may be located where the return air space is large enough that a negative pressure is not present, however, a trapped condensate line is recommended to ensure proper drainage of unit in case a negative condition should occur (see Installation Drawings for locations and sizes). The drain should always be connected or piped to an acceptable disposal point sloped away from the unit at least 1/8" per foot LD04801 FIG. 6 – TYPICAL CONDENSATE PIPING TABLE 2 - DRAIN LINE SIZES UNIT PRIMARY SECONDARY YHBC 3/4 MPT 5/8 OD YPHBC 3/4 MPT 3/4 MPT YRHBC 3/4 MPT 3/4 MPT YHH 3/4 MPT 7/8 OD YPHH 3/4 MPT 7/8 OD YHYB 3/4 MPT 3/4 MPT YPHYB 3/4 MPT 3/4 MPT 7 FORM 115.20-NOM2 (105) INSTALLATION Ceiling Concealed Model – MODEL YHBC 6 NOM. CFM (100's) 3, 4, 5, 6, 8, 10 or 13 YP HBC - 126 - 3 RH Coil Connections (looking with airflow, from blower end) RH = Right Hand LH = Left Hand Unit Style Y - Ceiling Concealed YP - with return plenum & filter YR - recessed w/telescoping panel YC - cabinet exposed HBC - Horizontal Blower Coil Coil Configuration 3 = 2 Pipe Coil, 3 Row 4 = 2 Pipe Coil, 4 Row 31 = 4 Pipe Coil, 3 Row Cool 1 Row Heat 32 = 4 Pipe Coil, 3 Row Cool 2 Row Heat 41 = 4 Pipe Coil, 4 Row Cool 1 Row Heat Unit Voltage 126 - 120V – 1 Ph – 60 Hz Filter Note: YHBC units are not available with filters. YHBC units can be field converted YHBC to YPHBC by adding an accessory plenum. See instruction below for details on field conversion. FIELD CONVERSION YHBC TO YPHBC Remove 2 screws holding the motor/blower assembly to the fan coil unit; remove and discard the drip guard; remove the bottom panel from the plenum; attach the plenum box to the fan coil unit using 5 screws; re-install the motor/blower assembly to the fan coil unit; for wiring, remove the motor leads from the j-box and attach the box to the outside of the plenum; route the motor leads to the j-box; replace the bottom panel; install the filter; if hanger brackets are needed, attach to the plenum, both ends. ��� ���������� ������ ��� ���� �������� �� �������� �������� ������ PHYSICAL DIMENSIONS (inches) MODEL A B C D 3YHBC 30-1/8 27-1/4 20-1/8 25-1/4 4YHBC 36-1/8 33-1/4 26-1/8 31-1/4 5YHBC 40-1/8 37-1/4 30-1/8 35-1/4 6YHBC 40-1/8 37-1/4 30-1/8 35-1/4 8YHBC 46-1/8 43-1/4 36-1/8 41-1/4 10YHBC 52-1/8 49-1/4 42-1/8 47-1/4 13YHBC 59-1/8 56-1/4 49-1/8 54-1/4 ��� ���� ����� ����� ������� ��������� ����� ���� ���� ������� � ������� ����� ���� ��� NOTES: 1. Model 3 YHBC has only one blower 2. Model 13 YHBC has four blowers and two motors ����� ����� ����� � ������� � ������ ����� ��� ����� �� ��� ���� ���� ����� ������� ����� � ���� � � ���� ���� ����� 8 ����� ����� ���� ����� ����� � ���� ���� ����� ��� ����� ��� ������ ����������� �� �������� ���� �� ��� ����� LD047768B YORK INTERNATIONAL FORM 115.20-NOM2 (105) INSTALLATION Ceiling Concealed Model with Insulated Return Plenum and Filter – MODEL YPHBC ���� ������ �������� ���� ������ ������ ������ ������ ���� ���� ���� ��� � � � � �� �� ��� ������ � ����� ���� ���� ���� ����� ������� ���������� ����� ������� ���������� ��������� ������� ���� ��� ��� ��� �� ������ �� ���� LD010229 . PHYSICAL DIMENSIONS - INCHES MODEL A B C D E FILTER SIZE 3YPHBC 24 22 20-1/8 30-1/8 27-1/4 10 X 24 X 1 4YPHBC 30 28 26-1/8 36-1/8 33-1/4 10 X 30 X 1 5YPHBC 34 32 30-1/8 40-1/8 37-1/4 10 X 34 X 1 6YPHBC 34 32 30-1/8 40-1/8 37-1/4 10 X 34 X 1 8YPHBC 40 38 36-1/8 46-1/8 43-1/4 10 X 40 X 1 10YPHBC 46 44 42-1/8 52-1/8 49-1/4 10 X 46 X 1 13YPHBC 53 51 49-1/8 59-1/8 56-1/4 10 X 53 X 1 NOTES: 1) Return plenums are insulated 2) YPHBC units are provided with filters in the plenum. 3) Standard plenums are end return and can be field converted to bottom return by trading the blockoff and face panel of the plenum. 4) Filter has seperate filter access panel for easier service. YORK INTERNATIONAL 9 FORM 115.20-NOM2 (105) INSTALLATION CEILING EXPOSED CABINET – MODEL YCHBC ������ �� ��� ���������� �� ������� �� ���� ���������� ��������� �� � ����� �� ��� ����������� ��� ���� ��� �� ����� ����� ��� ��������� ���� ������� �� ��� �������� ������ ������ ��� ��� ��� ������� � ������ � ����� ���� ����������� ���� ����� ���� ����� ���� ���� ���� ����� ����� �������� ��� ����� ������ ����� ���� �������� ����� ����� ������ �� � ����� ���� ����� ���� ���� ����������� ���� ����� ����� ����� ��� ����� ��������� ��� ������ �� �������� ��������� ��� ���� ���� ������� ����� ����� ����� ����� ��� ����� ����� ������ ������ ������ ������� ���� ������ ���� ���� �� ������ � ������ ������ ������ ��������� �� ���� ������ ��� ��������� ��� ������ ����� ������� �� ������� ����� ������ ��� �������� ��� ���� ������ ������� LD010230 GENERAL DIMENSIONS MODEL UNIT WIDTH A MOUNTING WIDTH B SUPPLY LOUVERED PANEL WIDTH C RETURN LOUVERED PANEL WIDTH E FILTER SIZE (INCL) 3YCHBC 38 34 26 31-1/2 10 X 37 X1 4YCHBC 44 40 31-1/2 37 10 X 43 X1 5YCHBC 48 44 37 42-1/2 10 X 46 X1 6YCHBC 48 44 37 42-1/2 10 X 46 X1 8YCHBC 54 50 42-1/2 48 10 X 53 X1 10YCHBC 60 56 48 53 10 X 59 X1 13YCHBC 67 63 53 58-1/2 10 X 65 X1 10 YORK INTERNATIONAL FORM 115.20-NOM2 (105) INSTALLATION RECESSED CEILING – MODEL YRHBC ����� � ����� ����� ����� ��������� ��� ������ ����� ������ ������ ������ ����� � � � � ������ ��� ���� ���� ����������� � ����� ����� �� ��� �� �� � � ���� ��� ��� ��� ���� ��� ���� ����� ���� ����������� ��� ���� �� ����� ���� ���� ��� ���� ��� ��� ��� ������� ��� ����� ������ ����� ���� � ����� ������� ����� ��� ��� ���� ������ ��� ����� ������� ��� ���� ������ ��� NOTES: 1. Telescoping panel allows the cabinet to be installed to within 2 inches of the ceiling line. 2. Telescoping access panel shipped as seperate item. 3. YRHBC units are available with filters on units with louvered access panels ONLY. ��� All 1-1/2" dia. K.O.;s ��� ��� * 4-Pipe system only ������� ���� LD010220 GENERAL DIMENSIONS (Inches) MODEL PANEL WIDTH (A) UNIT WIDTH (B) SUPPLY OPENING (C) LOUVERED MOUNTING PANEL'WIDTH WIDTH (E) (H) RETURN OPENING* (I) FILTER SIZE (INCL) 3YRHBC 41 38-3/8 29 36-5/8 35 14 10 x 37 x 1 4YRHBC 47 44-3/8 35 5YRHBC 51 48-3/8 39 41-3/4 41 20 10 x 43 x 1 47-1/4 45 24 10 x 47.5 x 1 6YRHBC 51 48-3/8 39 47-1/4 45 24 10 x 47.5 x 1 8YRHBC 57 54-3/8 45 52-1/2 51 30 10 x 53 x 1 10YRHBC 67 60-3/8 51 57-7/8 57 36 10 x 59 x 1 13YRHBC 70 67-3/8 58 63-1/8 64 42 10 x 65 x 1 * Field cut for above ceiling return. YORK INTERNATIONAL 11 FORM 115.20-NOM2 (105) INSTALLATION Ceiling Concealed Model with Electric Heat – MODEL YHH 6 Y HHS - 6.0 - 240 - 3 - RH NOM. CFM (100's) 3,4,6,8,10 or 12 Coil Connections (looking with airflow, from blower end) RH = Right Hand LH = Left Hand Unit Style Y - basic unit YP - with insulated return plenum Coil Configuration 3 = 2 Pipe Coil, 3 Row 4 = 2 Pipe Coil, 4 Row Voltage (1) 240 / 1 / 60 (2) 208 / 1 / 60 (3) 277 / 1 / 60 Motor Type HH - PSC Motor HHS - SP Motor Electric Heat (kW) 6.0 kW 10.0 kW Notes: 1. Fuse size and wire size per ampacities on unit nameplate. Follow NEC guidelines in absence of local codes. PHYSICAL DIMENSIONS (INCHES) MODEL OVERALL WIDTH A MOUNTING WIDTH B SUPPLY OPENING C 3YHHS 25 19-11/16 15 40 34-11/16 30 10YHH 46 40-11/16 36 12YHH 52 46-11/16 42 4YHHS 6YHHS 6YHH 8YHH 2. YHH units are not available with filters. � � ��� ���� ������ ������� ��� ���� �� ������ �� � ����������� ���� ���� ����� � � ��� ������ ���� ������ ����� ���� � � �� ������� ��� ��� ������� ������ ���� ��� ��� ������ ������� ������ �������� ��� ����� ���� ���� ������� ����� ���� ��� � ��������� ����� ���� ���� ����� ����� �������� ����� ����� ���� ����� � ���� ���� ����� ��� ����� ��� ������ ����������� �� �������� ���� �� ��� ����� LD010233 12 YORK INTERNATIONAL FORM 115.20-NOM2 (105) INSTALLATION Ceiling Concealed Model with Electric Heat, Insulated Return Plenum and Filter – MODEL YPHH � � ������ ��������� ����� ���� ��� ��� ������� ������� ����� ���� ��� ������ �������� ������ � ������ � � LD010231 ����� ���� ����� ����� � ���� ���� ����� ��� ����� ��� ������ ����������� �� �������� ���� �� ��� ����� PHYSICAL DIMENSIONS (INCHES) MODEL OVERALL WIDTH A MOUNTING WIDTH B SUPPLY OPENING C PLENUM WIDTH D RETURN OPENING E FILTER (INCL) 3YPHHS 25 19-11/16 15 20 18 10 X 20 X 1 40 34-11/16 30 34 32 10 X 34 X 1 10YPHH 46 40-11/16 36 40 38 10 X 40 X 1 12YPHH 52 46-11/16 42 46 44 10 X 46 X 1 4YPHHS 6YPHHS 6YPHH 8YPHH YPHH FEATURES: YORK INTERNATIONAL 1) Return Plenums are insulated. 2) All plenums include throw away filter. 13 FORM 115.20-NOM2 (105) INSTALLATION MODEL YHYB – High Capacity Ceiling Concealed Model 12 YP HYB NOM. CFM (100's) 12,16 or 20 - 126 - 3 RH Coil Connections (looking with airflow, from blower end) RH = Right Hand LH = Left Hand Unit Style Y -high capacity ceiling concealed YP - with return plenum & filter HYB - Horizontal Blower Coil Coil Configuration 3 = 2 Pipe Coil, 3 Row 4 = 2 Pipe Coil, 4 Row 6 = 2 Pipe Coil, 6 Row 31 = 4 Pipe Coil, 3 Row Cool, 1 Row Heat 32 = 4 Pipe Coil, 3 Row Cool, 2 Row Heat 41 = 4 Pipe Coil, 4 Row Cool, 1 Row Heat 42 = 4 Pipe Coil, 4 Row Cool, 2 Row Heat 61 = 4 Pipe Coil, 6 Row Cool, 1 Row Heat 62 = 4 Pipe Coil, 6 Row Cool, 2 Row Heat Unit Voltage 126 - 120V – 1 Ph – 60 Hz 277 - 277V – 1 Ph – 60 Hz Notes: 1. YHYB units are not available with filters. 2. YPHYB units are provided with filters in the plenum. PHYSICAL DIMENSIONS (INCHES) MODEL OVERALL TOP SUPPLY MOUNTING RETURN WIDTH PLATE OPENING WIDTH OPENING A WIDTH C D E B FILTER (INCL) 12YHYB 41 35-1/2 28 31-1/4 23-1/4 ___ 12YPHYB 41 35-1/2 28 31-1/4 23-1/4 16YHYB 51 42-1/2 38 41-1/4 38-1/4 14 x 28 x 1 ___ 16YPHYB 51 42-1/2 38 41-1/4 38-1/4 20YHYB 60 51-1/2 47 50-1/4 47-1/4 14 x 38 x 1 ___ 20YPHYB 60 51-1/2 47 50-1/4 47-1/4 14 x 43 x 1 ����� �� � ��� ������ ������� ��� ��� ���� ����� ������ ����� ��� ��� ����� ������� ��� ��������� � ����� � ����� ���� ���� ����� ������ ������ ������ ����� � ��� �� ����������� �� ��� ����� ��� ��� ��� �� ��� ��� ����� ������� ��� ��������� ���� � ����� ���� ���� ����� 14 5. 6. 7. 8. Manual air vents 4-speed direct drive motors 1/2" copper tubing Primary and secondary condensate drains on one end 120/1/60Hz. motors (2) 3-row and 6-row models available Rubber isolation grommets Insulated and coated drain pan ������ ������ �� ������ ������� FEATURES: 1. 2. 3. 4. ����� �� � � ��� ��������� �������� ��������� LD04781 YORK INTERNATIONAL FORM 115.20-NOM2 (105) FAN COILS START - UP CHECKLIST INSTALL CHECKLIST Equipment received as ordered. Unit checked for damage interior and exterior. Make sure all ductwork is complete and available for full air flow. Unit installed level to ensure proper drainage and operation. Unit installed with proper clearances. Ensure condensate water will drain toward the drain connection. An overflow drain may be required as a back up to a clogged primary drain. Check that coil(s), valves and piping have been leak checked and insulated as required. Main coil drain pan must be properly trapped and charged with water before units are started. Ensure that all air has been vented from the system. Return valves to their proper operating positions prior to start-up. Repair any solder joint leaks and gently tighten any leaking valve packing nuts and piping accessories as required. Install all panels. NOTE: If the motor and fan have not been operated in the last (4) four weeks or more, lubricate all the bearings and rotate the motor and fan monthly to prevent moisture from accumulating in the bearings. (See Form 50.20-NM3, Long Term Storage) CLEANING CHECKLIST Installer has cleaned out interior. Ensure drain pan free from foreign material. Ensure air filters are clean, installed properly and secured. Use the directional arrows or other information on the filter to determine the proper flow direction. CONTROLS CHECKLIST Check that supply voltage matches nameplate data. Ensure that the unit is properly grounded. Controls installation complete Check all electrical connections for tightness. Review electrical print for correct wiring. Fan INSPECTION - The fan should be inspected and cleaned, in conjunction with maintenance of the motor and bearings. It is important to keep the wheel clean in order to avoid imbalance and vibration. Check tightness of fan bearing locking collar. With power off, check blower wheel set screws for tightness and ensure that the blower wheel(s) rotate freely and quietly. Check tightness of all motor base and mounting bolts. Check motor connections to ensure that they are secure and made in accordance with the wiring diagram Rotate all moving components manually. Adjust as required. YORK INTERNATIONAL 15 MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufficient. COIL The coil must be kept clean by any of the following methods. 1. Cleaning with low-pressure compressed air. 2. Flushing or rinsing with water (a detergent is advisable for greasy surfaces). 3. Prior to the water system start-up and balancing, the chilled/hot water systems should be flushed to clean out dirt and debris, which may have accumulated during construction. All unit service valves are to be closed during this process. Strainers are to be installed in the piping mains to prevent this material from entering the units during normal operation. Because of dust and lint in the room, room-air filters load up much more rapidly than outdoor-air filters. Under normal conditions, the room air filter requires replacement every six to eight weeks. To ensure proper maintenance of the filters, it is best to follow an organized maintenance procedure. The following one is recommended: Divide the total number of units on the job into six equal groups. Each week inspect, clean or replace the filters in each group, in rotation. This insures a uniform servicing interval. The interval may be lengthened or shortened as determined by experience. If inspection shows only the room-air filter to be dirty, this one alone should be replaced. Dirty filters reduce the air and heating capacities of the Unit Ventilator. When the filters are excessively dirty, the unit heating capacity will be so reduced that it is ineffective for heating the room. When a room fails to heat, always check the filters. FILTERS Clean or Replace Air Filters Regularly CLEAN UNIT INTERIOR Once a year clean the fans and coils of the unit thoroughly. Remove the access panel as necessary. The intervals at which filters require replacement depend on local conditions. P.O. Box 1592, York, Pennsylvania USA 17405-1592 Copyright © by York International Corporation 2004 Form 115.20-NOM2 (105) Supercedes 115.20-NOM2 (904) Wipe the interior of the unit clean with a rag. Wipe the motor and inside and outside of the fan housings. (In cooling units, clean out the drain pan.) Tele. 800-861-1001 www.York.com Subject to change without notice. Printed in USA ALL RIGHTS RESERVED
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Modify Date : 2005:02:15 14:44:19-05:00 Create Date : 2005:01:24 14:42:24Z Producer : Adobe PDF Library 5.0 Creator : Adobe InDesign 2.0.1 Trapped : False Page Count : 16 Creation Date : 2005:01:24 14:42:24Z Mod Date : 2005:02:15 14:44:19-05:00 Metadata Date : 2005:02:15 14:44:19-05:00 Document ID : adobe:docid:indd:12601c93-6e40-11d9-91bc-b081aeec5f08 Version ID : 1 Rendition Class : proof:pdf Rendition Of Document ID : adobe:docid:indd:12601c93-6e40-11d9-91bc-b081aeec5f08 Rendition Of Version ID : 1 Rendition Of Rendition Class : default Format : application/pdf Title : 115.20-NOM2_105.indd Tagged PDF : Yes Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools