York Air Conditioner R 410A Zh Zj Zr Series Users Manual 528150 YTG G 1210
R-410A ZHZJZR Series to the manual 1bac44e6-e526-4e06-a605-16b64416feff
2015-02-02
: York York-Air-Conditioner-R-410A-Zh-Zj-Zr-Series-Users-Manual york-york-air-conditioner-r-410a-zh-zj-zr-series-users-manual-455242 york pdf
Open the PDF directly: View PDF
Page Count: 206 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- Description
- Table of Contents
- Component Location
- Nomenclature
- Features and Benefits
- Guide Specifications
- Physical Data
- ZH037-061 Single Stage Gas Physical Data
- ZH037-061 Two Stage Gas Physical Data
- ZH078-150 Physical Data
- ZJ037-061 Single Stage Gas Heat Physical Data
- ZJ037-061 Two Stage Gas Heat Physical Data
- ZJ078-150 Physical Data
- ZR037-061 Single Stage Gas Heat Physical Data
- ZR078-150 Physical Data
- ZH/ZJ/ZR078-150 Unit Limitations
- Capacity Performance
- ZH037-150 Cooling Capacities
- ZJ037-150 Cooling Capacities
- ZR037-150 Cooling and Reheat Capacities
- Airflow Performance
- Altitude/Temperature Correction Factors
- Indoor Blower Specifications
- Power Exhaust Specifications
- RPM Selection
- Additional Static Resistance - ZH037 thru 061
- Additional Static Resistance - ZJ/ZR037 thru 061
- Additional Static Resistance - ZH/ZR078 thru 150
- Additional Static Resistance - ZJ078-150
- Gas Heat Minimum Supply Air
- Electric Heat Minimum Supply Air
- Airflow Performance
- Sound Performance
- Indoor Sound Power Levels (3 thru 5 Ton)
- Indoor Sound Power Levels (Horizontal Ducted Inlet, Standard Static Belt Drive)
- Indoor Sound Power Levels (Horizontal Ducted Discharge, Standard Static Belt Drive)
- Indoor Sound Power Levels (Vertical Ducted Inlet, Standard Static Belt Drive)
- Indoor Sound Power Levels (Vertical Ducted Discharge, Standard Static Belt Drive)
- Indoor Sound Power Levels (Horizontal Ducted Inlet, High Static Belt Drive)
- Indoor Sound Power Levels (Horizontal Ducted Discharge, High Static Belt Drive)
- Indoor Sound Power Levels (Vertical Ducted Inlet, High Static Belt Drive)
- Indoor Sound Power Levels (Vertical Ducted Discharge, High Static Belt Drive)
- Indoor Sound Power Levels (6.5 thru 12.5 Ton)
- Outdoor Sound Power Levels ZH/ZJ/ZR037-150
- Electrical Data
- ZH037-061 Standard Indoor Blower - Without Powered Convenience Outlet
- ZH078-150 Standard Motor - Without Powered Convenience Outlet
- ZH037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet
- ZH078-150 Hi Static Motor - Without Powered Convenience Outlet
- ZH037-061 Standard Indoor Blower - With Powered Convenience Outlet
- ZH078-150 Standard Motor - With Powered Convenience Outlet
- ZH037-061 Hi Static Indoor Blower - With Powered Convenience Outlet
- ZH078-150 Hi Static Motor - With Powered Convenience Outlet
- ZJ037-061 Standard Indoor Blower - Without Powered Convenience Outlet
- ZJ037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet
- ZJ037-061 Standard Indoor Blower - With Powered Convenience Outlet
- ZJ037-061 Hi Static Blower - With Powered Convenience Outlet
- ZJ078-150 Hi Static Motor - With Powered Convenience Outlet
- ZR037-061 Standard Indoor Blower - Without Powered Convenience Outlet
- ZR037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet
- ZR037-061 Standard Indoor Blower - With Powered Convenience Outlet
- ZR037-061 Hi Static Indoor Blower - With Powered Convenience Outlet
- Electric Heat Multipliers
- Typical Wiring Diagrams
- ZH/ZJ037-150 Typical Wiring Diagrams
- Typical ZH/ZJ037-061 Cooling Unit with Gas Heat 230 Volt Wiring Diagram
- Typical ZR037-061 Reheat Unit with Gas Heat 230 Volt Wiring Diagram
- Typical ZH/ZJ037-061 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram
- Typical ZR037-061 Reheat Unit with Gas Heat 460/575 Volt Wiring Diagram
- Typical ZH/ZJ037-061 Cooling Unit with/without Electric Heat Wiring Diagram
- Typical ZR037-061 Reheat Unit with/without Electric Heat Wiring Diagram
- Typical ZH/ZJ/ZR078-120 Cooling Unit with Gas Heat 230 Volt Wiring Diagram
- Typical ZH/ZJ/ZR078-120 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram
- Typical ZH/ZJ/ZR078-120 Cooling Unit with/without Electric Heat Wiring Diagram
- Typical ZH/ZJ/ZR150 Cooling Unit with Gas Heat 230 Volt Wiring Diagram
- Typical ZH/ZJ/ZR150 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram
- Typical ZR037-061 Reheat Wiring Diagram
- Typical ZR078-120 Reheat Wiring Diagram
- Typical ZR150 Reheat Wiring Diagram
- Typical ZH/ZJ078-150 Factory Installed VFD (Option)
- Typical ZH/ZJ078-150 Factory Installed VFD with Manual Bypass (Option)
- Typical ZH/ZJ078-150 BAS Ready Unit with Factory Installed VFD (Option)
- Typical ZH/ZJ078-150 BAS Ready Unit with Factory Installed VFD and Manual Bypass (Option)
- Typical ZH/ZJ078-150 VFD Ready Unit (Option)
- ZH/ZJ037-150 Typical Wiring Diagrams
- Weights and Dimensions
- Weights and Dimensions
- ZR037-150 Unit Weights
- ZH/ZJ/ZR037-150 Unit Accessory Weights
- ZH/ZJ/ZR037-150 Unit Dimensions
- ZH037-061 and ZJ/ZR037
- ZJ/ZR049 thru 061 and ZH/ZJ/ZR078 thru 120
- ZH150
- ZJ/ZR150
- ZH/ZJ/ZR037-150 Unit Physical Dimensions
- ZH/ZJ/ZR037-150 Unit Clearances
- ZH/ZJ/ZR037-150 Unit Bottom Duct Openings
- ZH/ZJ/ZR037-150 Unit Electrical Entry
- ZH/ZJ/ZR037-120 Unit Side Duct Openings
- ZH150 Unit Side Duct Openings
- ZJ/ZR150 Unit Side Duct Openings
- ZH/ZJ/ZR037-150 Unit Left Duct Opening
- ZH/ZJ/ZR037-150 Unit Accessory Dimensions
- Economizer Options