York Zh Predator R410A 11 7 Eer Technical Guide 528150 YTG T 0514
2015-09-09
: York Zh-Predator-R410A-11-7-Eer-Technical-Guide york-zh-predator-r410a-11-7-eer-technical-guide-812284 york pdf
Open the PDF directly: View PDF .
Page Count: 204
Download | ![]() |
Open PDF In Browser | View PDF |
528150-YTG-T-0514 ® TECHNICAL GUIDE R-410A ZH/ZJ/ZR SERIES 3 - 12-1/2 TON 60 Hertz Description ASHRAE 90.1 COMPLIANT YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 3 through 12-1/2 ton models. All 6-1/2 through 12-1/2 ton units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, cooling with gas heat, reheat only, reheat with electric heat and reheat with gas heat. Electric heaters are available as factory-installed options or field-installed accessories. ZH/ZJ/ZR 3 THROUGH 10 TON All units provide constant supply air volume. A variable air volume (VAV) option, featuring a variable frequency drive, is available on 6-1/2 through 12-1/2 ton ZH/ZJ models only. Tested in accordance with: ZH/ZJ/ZR 12-1/2 TON FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 528150-YTG-T-0514 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Economizer Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 Component Location Cooling With Gas Heat (3 Through 5 Ton) “Simplicity®” Control board w/ screw connectors for T-stat wiring and Network Connections Disconnect location (optional disconnect switch) Filter drier (solid core) Filter access 3-5 Ton Reheat (2" or 4” Micro-Channel Aluminum filter options) Tube/Aluminum Fin Condenser (Single Orifice System shown. See Actual Model Physical Data for details) Slide out motor and blower assembly for easy adjustment and service Filter drier (solid core) 3-5 Ton Cooling Second model nameplate inside hinged access panel Belt-drive blower motor Base rails w/ forklift slots (three sides) and lifting holes Roof curbs in eight-and fourteen-inch heights. Roof curbs for transitioning from York Sunline™ footprint to the ZH/ZJ/ZR Series footprint are available (field-installed accessory) Compressor access (highefficiency compressor) Power ventor motor 20-gauge aluminized steel tubular heat exchanger for long life (stainless steel option) Side entry power and control wiring knockouts Toolless door latch 2 Slide-out drain pan with ¾" NPT connection One or Two stage gas heating to maintain warm, comfortable temperature Intelligent control board for safe and efficient operation Johnson Controls Unitary Products 528150-YTG-T-0514 Cooling With Gas Heat (6 1/2 Through 10 Tons) Simplicity® control board Disconnect location w/screw connector for T-stat wiring and network connections (optional disconnect switch) Filter access (2” or 4” filter options) Filter drier (solid core) Micro-Channel Aluminum Tube/Aluminum Fin Condenser Terminal block for hi-voltage connection Second model nameplate inside hinged access panel Slide-out motor and blower assembly for easy adjustment and service Belt-drive blower motor Dual stage cooling for maximum comfort VFD location (optional) Power ventor motor Compressor #2 access (highefficiency compressor) 20-gauge aluminized steel tubular heat exchanger for long life (stainless steel option) Base rails w/forklift slots (three sides) and lifting holes Roof curbs in eight- and fourteen-inch heights. Roof curbs for transitioning from York Sunline™ footprint to the ZH/ZJ/ZR Series footprints are also available (field installed accessory) Johnson Controls Unitary Products Slide-out drain pan with 3/4” NPT, female connection Toolless door latch Side entry power and control wiring knockouts Two-stage gas heating to maintain warm, comfortable temperature Intelligent control board for safe and efficient operation Compressor #1 access (high-efficiency compressor) 3 528150-YTG-T-0514 Nomenclature 3-12.5 Ton York® Model Number Nomenclature Z H 090 N10 A 2 A AA 6 0 1 2 4 A Product Category Product Style A = Style A B = Style B C = Style C Z = A/C, Single Pkg., R-410A Product Identifier H = 11.7-11.8 EER J = 12.2 EER R = Reheat Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. SS Drain Pan CPC Controller, DFS, APS Nominal Cooling Capacity 037 = 3 Ton 049 = 4 Ton 061 = 5 Ton 078 = 6.5 Ton 090 = 7.5 Ton 102 = 8.5 Ton 120 = 10.0 Ton 150 = 12.5 Ton Johnson Controller UNT 1126 (N2 protocol), DFS, APS Honeywell Controller, DFS, APS Novar Controller, DFS, APS Simplicity IntelliComfort II Controller Simplicity IntelliComfort II Controller w/Simplicity®LINC York Commercial Comfort System (YCCS) Rtu Controller Hot Gas Bypass (Standard on VAV, Optional on CV) IntelliSpeed with VFD Heat Type and Nominal Heat Capacity (Unit Size Allowed) C00 = Cooling Only. No heat installed Single Stage Natural Gas Heat Options A05 = 49 MBH Output Aluminized Steel, Single Stage (037, 049) A07 = 65 MBH Output Aluminized Steel, Single Stage (037, 049, 061) A09 = 97 MBH Output Aluminized Steel, Single Stage (037, 049, 061) A13 = 129 MBH Output Aluminized Steel, Single Stage (061) B05 = 49 MBH Output Stainless Sleel, Single Stage (037, 049) B07 = 65 MBH Output Stainless Steel, Single Stage (037, 049, 061) B09 = 97 MBH Output Stainless Steel, Single Stage (037, 049, 061) B13 = 129 MBH Output Stainless Steel, Single Stage (061) IntelliSpeed, VFD and Manual Bypass IntelliSpeed, VFD Ready (for customer-provided, field-installed drive) Variable Air Volume, VFD (not available with factory installed BAS options) Variable Air Volume, VFD with Simplicity®LINC (not available with factory installed BAS options) Variable Air Volume, VFD and Manual Bypass (not available with factory installed BAS options) Variable Air Volume, VFD and Manual Bypass with Simplicity®LINC (not available with factory installed BAS options) Variable Air Volume, VFD (BAS ready) Variable Air Volume, VFD and Manual Bypass (BAS ready) Variable Air Volume, VFD Ready (for customer-provided, field-installed drive) Variable Air Volume, VFD Ready with Simplicity®LINC (for customer-provided, field-installed drive) 2" Pleated Filters, MERV 7 4" Pleated Filters, MERV 13 BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller) Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned Two Stage Natural Gas Heat Options N05 = 49 MBH Output Aluminized Steel, Two Stage (037, 049) N07 = 65 MBH Output Aluminized Steel, Two Stage (037, 049, 061) N09 = 97 MBH Output Aluminized Steel, Two Stage (037, 049, 061) N13 = 129 MBH Output Aluminized Steel, Two Stage (061) S05 = 49 MBH Output Stainless Sleel, Two Stage (037, 049) S07 = 65 MBH Output Stainless Steel, Two Stage (037, 049, 061) S09 = 97 MBH Output Stainless Steel, Two Stage (037, 049, 061) S13 = 129 MBH Output Stainless Steel, Two Stage (061) N10 = 100 MBH Output Aluminized Steel, Two Stage (078, 090, 102) N15 = 150 MBH Output Aluminized Steel, Two Stage (078, 090, 102, 120, 150) N20 = 200 MBH Output Aluminized Steel, Two Stage (120, 150) S10 = 100 MBH Output Stainless Steel, Two Stage (078, 090, 102) S15 = 150 MBH Output Stainless Steel, Two Stage (078, 090, 102, 120, 150) S20 = 200 MBH Output Stainless Steel, Two Stage (120, 150) Electric Heat Options E03 = 3 KW (037) E06 = 6 KW (037, 049, 061) E08 = 9 KW (037, 049, 061) E09 = 9 KW (078, 090, 102) E15 = 15 KW (037, 049, 061) E18 = 18 KW (078, 090, 102, 120, 150) E20 = 20 KW (049, 061) E23 = 24 KW (061) E24 = 24 KW (078, 090, 102, 120, 150) E36 = 36 KW (078, 090, 102, 120, 150) E54 = 54 KW (120, 150) Product Generation 6 = Sixth Generation Additional Options AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch RC = Coil Guard, Shipping Bag & American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator & Condenser Coils EA = ElectroFin Condenser Coil EJ = ElectroFin Evaporator Coil ES = ElectroFin Cond & Evap Coils ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Installation Options Voltage 2 = 208/230-3-60 4 = 460-3-60 5 = 575-3-60 Airflow A = Std. Motor D = Std. Motor/Motorized Damper (Downflow Only) H = Std Motor/Low Leak Econ/Barometric Relief (Downflow, Slab Economizer Only) J = Std Motor/Low Leak Econ/Power Exhaust (Downflow, Slab Economizer Only) E = Std Motor/Horizontal Economizer (No Baro) N = Hi Static R = Hi Static/Motorized Damper (Downflow Only) V = Hi Static Mtr/Low Leak Econ/Barometric Relief (Downflow, Slab Economizer Only) W = Hi Static Mtr/Low Leak Econ/Power Exhaust (Downflow, Slab Economizer Only) S = Hi Static Mtr/Horizontal Economizer (No Baro) A = No Options Installed B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4 & 5 Options 1 = Disconnect 2 = Non-Pwr'd Conv. Outlet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet 4 Johnson Controls Unitary Products 528150-YTG-T-0514 Features and Benefits Standard Features • High Efficiency – High efficiency units reach as high as 12.2 EER. Gas/electric units have electronic spark ignition and power vented combustion with steady state efficiencies of 80%. These efficiencies exceed all legislated minimum levels and provide low operating costs. • Service Friendly – The Predator® incorporates a number of enhancements which improve serviceability. The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment. Service time is reduced through the use of hinged, toolless panels. Such panels provide access to frequently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other unauthorized persons. It is recommended that the panels be secured with screws once service is complete. Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection. Both the unit control board and ignition control board utilize flash codes to aid in diagnosis of unit malfunctions. Unique alarm codes quickly identify the source of the unit alarm. All units use four filters of the same standard size. This standardization simplifies selections for filter replacement. The non-corrosive drain pan slides out of the unit to permit easy cleaning. The drain pan is accessed by removing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit. All Predator® units have a second model nameplate located inside the control access door. This is to prevent deterioration of the nameplate through weathering. • Coil Technology – All ZH/ZJ condensers utilize MicroChannel “all-aluminum” condensers which provide improved heat transfer capabilities and reduced charge volumes. All evaporators utilize a conventional copper tube/aluminum fin design for proven reliability and performance. ZR037 thru 061 models utilize MicroChannel condenser coils, ZR078 thru 150 models utilize copper tube/aluminum fin condenser coils. • Environmentally Aware – For improved Indoor Air Quality, a combination of foil faced and elastometric rubber insulation is used exclusively throughout the units. • Balanced Heating – The Predator® two stage gas heating offers “Ultimate Heating Comfort” with a balance between 1st and 2nd stage gas heating. The first stage of a gas heat Predator® unit provides 70% or 75% of the heating capacity 3 thru 5 tons and 60% heating capacity 6-1/2 thru 12-1/2 tons. Balanced heating allows the unit to better maintain desired temperatures. • Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/ Johnson Controls Unitary Products • return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory. • System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and lowpressure switches. Internal compressor protection is standard on all compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation. Advanced Controls - Simplicity® control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. The Simplicity® control board used in this product will effectively operate the cooling system down to 0°F when this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1-877UPG-SERV for guidance. Additional accessories may be needed for stable operation at temperatures below 30° F. • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button. • Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control 5 528150-YTG-T-0514 board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. • • Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. • Reliable – From the beginning – All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term – All Predator® units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test. • Flexible Placement – All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the internal loads have been determined. To further simplify planning and installation, Predator® cabinets are designed to fit your roof. With the optional roof curb, the unit ductwork is designed to fit around 24” on-center joists or between 48” on-center joists. The drain pan can be rotated to drain to either the front or the rear of the unit. Additionally, the drain pan can be fitted to drain through the roof curb. As it is sometimes difficult to have a level installation, the drain pan features a generous slope to ensure proper drainage. • Full Perimeter Base Rails – The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer forklift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof. • Easy Installation – Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. All units are shipped with 2” throw-away filters installed. • Wide Range of Indoor Airflows – All indoor fan motors are belt-drive type providing maximum flexibility to handle most airflow requirements. For high static applications, factory installed alternate indoor fan motors are available. With the optional indoor fan motor, all units can supply nominal airflow at a minimum of 1.5” ESP. 6 A variable air volume (VAV) option using a variable frequency drive is available on 6-1/2 through 12-1/2 ton models for applications requiring a constant supply duct pressure. A differential pressure transducer is used to monitor supply duct static pressure while a VAV control board provides a speed reference signal to the VFD to control the output of the indoor blower motor. • Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10year warranty. Factory Installed Options YORK® offers several equipment options factory installed, for the Predator®line. • Optional Factory Installed Economizers - Predator units offer a variety of optional factory installed economizers with low leak dampers. The outdoor air enthalpy sensor enables economizer operation if the outdoor enthalpy is less than the setpoint of the economizer logic module. See economizer options section to determine the correct economizer for your application. • Downflow Slab Economizers (with barometric relief and fresh air hood) - All units offer a variety of optional factory installed down flow economizers that are shipped, installed and wired with low leak dampers designed to meet ASHRAE 90.1-2010, AMCA 511 Class 1A damper, and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/sq. ft. at 1" of static pressure. Each economizer goes through a rigorous 60,000 cycle test. Dry bulb, single enthalpy, and dual enthalpy (with field installed kit) can be selected. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the outdoor air dry bulb temperature or the outdoor air enthalpy input. The dual enthalpy kit provides a second input used to monitor the return air (field installed). The installer needs only to assemble the outdoor air hood, attach the enthalpy control the hood and mount the hood to the unit (Hood and control are provided). When selected with BAS Ready Economizer Option the actuator requires 2-10 VDC input from an external source, such as a field-installed or factory-installed BAS controller. BAS-ready actuators have an adjustable auxiliary end-switch for optional power exhaust control. • Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except economizer is not designed with low leak dampers and you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Johnson Controls Unitary Products 528150-YTG-T-0514 Barometric Relief for horizontal flow economizers only. • • • • • For units with optional VAV or Simplicity® Intelli-Comfort II™ control, a factory-installed, dry bulb sensor determines if outdoor air temperature is low enough to provide free-cooling operation. (Field-installed humidity sensors for either outdoor air or outdoor & return air streams are available for single enthalpy and differential enthalpy configurations, respectively). • VAV or Simplicity® INTELLI-Comfort II™ control, a factory-installed dry bulb sensor determines if outdoor air temperature is low enough to provide free-cooling operation. (Field-installed humidity sensors for either outdoor air or outdoor & return air streams are available for single enthalpy and differential enthalpy configurations, respectively.) Power Exhaust (Downflow only) - This accessory installs in the unit with a down flow economizer. Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. Alternate Indoor Blower Motor - For applications with high static restrictions, units are offered with optional indoor motors that provide higher static output and/or higher airflow, depending upon the installer’s needs. Variable Air Volume (VAV; 6-1/2 through 12-1/2 ton, only - A factory-installed variable frequency drive (VFD), mounted in the Blower Access compartment, is used to control the speed of the indoor blower motor in order to maintain a constant static pressure in the supply duct. A pressure transducer and VAV control board are mounted inside the control box. The drive comes completely wired and pre-programmed from the factory. An optional, factory-installed manual bypass switch available with factory-installed VFD can be found in the Blower Motor Access compartment. The switch can be used to either route power to the VFD for modulating control of the blower motor, to bypass the drive and operate the motor at full speed, or to power the drive (and not the motor) for diagnostic purposes. Due to space limitations, VAV is not available with any of the factory-installed BAS options, but is available with 'BAS-ready' models. Terminal blocks are provided in the control box for field wiring of the customer-installed BAS. A 'VFD-ready' option provides the provisions for a customer-installed drive. The unit comes with a mounting bracket installed in the Blower Access compartment which may accommodate other vendor's drives depending on their size. In order to utilize the unit's mounting bracket, the maximum recommended drive dimensions are limited to approximately 9" H x 5" W x 7.5" D. If the drive will not fit in the allotted space, then it will have to be mounted elsewhere; either within the building on a perpendicular wall which is not subjected to excessive temperature, vibration, humidity, dust, corrosive gas, Johnson Controls Unitary Products explosive gas, etc., or within an appropriate enclosure rated for outside installation to safeguard against moisture, dust and excessive heat. A terminal block located in the control box is provided for field connection of the VFD controls. • IntelliSpeed™ Supply Fan Control Option (ASHRAE 90.1 compliant, section 6.4.3.10) - Units configured with the IntelliSpeed™ Supply Fan Option will contain a VFD for variable volume supply fan operation. This option allows the supply fan RPM to vary based on the number of compressors or heating stages energized. The economizer's minimum position will also be configurable to vary based on the supply fan VFD frequency output. • Aluminized Steel Gas Heat Exchanger - For applications in non-corrosive environments. • Stainless Steel Gas Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. • Stainless Steel Drain Pan - An optional rust-proof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • Electric Heaters - The electric heaters range from 3kW to 54kW and are available in all the voltage options of the base units. All heaters are intended for single point power supply. • Disconnect Switch - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. • Convenience Outlet - (Non-Powered/Powered) - This option locates a 120V single-phase GFCI outlet with cover, on the corner of the unit housing adjacent to the compressors. The “Non-powered” option requires the installer to provide the 120V single-phase power source and wiring. The “Powered” option is powered by a stepdown transformer in the unit. Factory installed option only. • Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. Available for both the supply and/or return air configurations. • Filters - 2” Pleated MERV 7 or 4” Pleated MERV 13 are available to meet LEED requirements. A 2” Throwaway is shipped as standard. Factory-installed smoke detectors may be subjected to extreme temperatures during "off" times due to outside air infiltration. These smoke detectors have an operational limit of -4°F to 158°F. Smoke detectors installed in areas that could be outside this range will have to be relocated to prevent false alarms. • Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. (Standard on units with Scroll Compressors.) 7 528150-YTG-T-0514 • Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering the space between the inner condenser coil and the main cabinet. This is not a hail guard kit. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • ElectroFin® E-coat Condenser Coils - The condenser coils are coated with an epoxy polymer coating to protect against corrosion. • ElectroFin® E-coat Evaporator Coils - The evaporator coils are coated with an epoxy polymer coating to protect against corrosion. • Hot Gas Bypass - Allows operation during low load conditions while avoiding coil frosting and damage to compressor. When suction pressure falls below valve setpoint, the valve modulates hot gas to the inlet of the evaporator. HGBP is standard on all units with VAV and optional with constant-volume units. Control Options • Simplicity® INTELLI-Comfort II™ Control communicates on a MODBUS RTU protocol network - The York® Simplicity® INTELLI-Comfort II™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort II™ using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the onboard connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity® INTELLI-Comfort II™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • Simplicity® INTELLI-Comfort II™ with Simplicity®LINC Control - The York® Simplicity® INTELLI-Comfort II™ with Simplicity®LINC control is factory installed. It 8 • • • • • includes all the features of the INTELLI-Comfort II™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. Novar® BAS Control - The Novar® building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. York Commercial Comfort System (YCCS) - Provides rooftop system integration for YCCS single zone and change-over bypass systems. Field Installed Accessories YORK® offers several equipment accessories for field installation, for the Predator® line. • Downflow Slab Economizers (with fresh air hood and without barometric relief) - All units offer a variety of optional factory installed down flow economizers that are shipped, installed and wired with low leak dampers designed to meet ASHRAE 90.1-2010, AMCA 511 Class 1A damper, and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/sq. ft. at 1" of static pressure. Each economizer goes through a rigorous 60,000 cycle test. Dry bulb, single enthalpy, and dual enthalpy (with field installed kit) can be selected. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the outdoor air dry bulb temperature or the outdoor air enthalpy input. The dual enthalpy kit provides a second input used to monitor the return air (field installed). The installer needs only to assemble the outdoor air hood, attach the enthalpy control the hood and mount the hood to the unit (Hood and control are provided). • Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except economizer is not designed with low leak dampers and you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Barometric Relief for horizontal flow economizers only. • Dual Enthalpy Control, Accessory - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. Johnson Controls Unitary Products 528150-YTG-T-0514 • Barometric Relief Damper - Zero to 100% capacity barometric relief dampers for use with horizontal flow, or field installed slab economizers. • Power Exhaust - This accessory installs in the unit with a down flow economizer. Power exhaust plugs into the connector in the unit bulkhead. You must purchase 1EH0408 barometric relief when applying to a horizontal flow application. • Manual Outdoor Air Damper - Like the motorized outdoor air damper, each manual outdoor air damper includes a slide-in damper assembly with an outdoor air hood and filters. Customers have a choice of dampers with ranges of 0% to 100% or 0% to 35% outdoor air entry. • Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. • Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the preset limits. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. • Coil Guard - Field installed decorative wire coil guard. • Hail Guard - This kit includes a sloped hood which installs over the outside condenser coil and prevents damage to the coil fins from hail strikes. Field installed accessory only. • Flue Exhaust Extension Kit - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. • -60°F Gas Heat Kit - For installations which require gas heat units to perform in low ambient temperatures, a gas section heating kit is available. This kit provides electric heat in the gas heat controls section to ensure the gas valve and controls will continue to function properly at extremely low temperatures. Johnson Controls Unitary Products • Gas Heat High Altitude Kit - This kit converts a gas heat unit to operate at high altitudes, 2,000 to 6,000 feet. Conversion kits are available for natural gas and propane. • Gas Heat Propane Conversion Kit - This kit converts a gas-fired heater from natural gas to propane. It contains the main burner orifices and gas valve replacement springs. • Gas Piping Kit - Contains pipe nipples, fittings and gas cock required for gas supply connection with external shut off. • Electric Heaters - The electric heaters range from 3kW to 54kW and are available in all the voltage options of the base units. The 54kW/208-240 volt, field-installed heater kit is not available with VAV units due to a lack of space to accommodate the heater’s fuse block accessory. All heaters are dual staged. Cooling units include an adapter panel for easy installation of the electric heaters. Necessary hardware and connectors are included with the heaters. All heaters are intended for single point power supply. • Low Limit / Compressor Lockout Kit • Compressor Lockout (CLO): To prevent mechanical (compressorized) operation of the unit during cold outdoor conditions where there is a risk of returning liquid refrigerant back to the compressors. • Low Limit Control (LLC): To prevent the supply air from dropping below a specified setpoint by utilizing the units first stage heating means when there is a demand for cooling during cold outside conditions. • Metal Frame Filter Kit - Metal frame with polyester filter medium. • Permanent Filters - Permanent filters are available. • Roof Curbs - The roof curbs have insulated decks and are shipped disassembled The roof curbs are available in 8” and 14” heights. For applications with security concerns, burglar bars are available for the duct openings of the roof curbs. • Roof Curb Transition - Single Piece Adapter (10” High) Roof curbs for transitioning from Sunline™ units to Predator® units. Fits 7.5 to 12.5 Sunline™ roof curbs only. • Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work. • Thermostat - The units are designed to operate with 24volt electronic and electro-mechanical thermostats. All 6.5 thru 12.5 ton ZH,ZJ units and all 3 thru 12.5 ton ZR units (with or without an economizer) operate with two-stage heat/two-stage cool or two-stage cooling only thermostats, depending upon unit configuration. 9 528150-YTG-T-0514 Accessories Field Installed Accessories - Non-Electrical MODEL 1BD0408 VOLTAGE DESCRIPTION All Burglar Bars, Downflow 1CG0419 1CG0420 1CG0427 1CG0428 All All All All Coil Guard Coil Guard Coil Guard Coil Guard 1HG0411 1HG0415 1FE0412 1FF0414 1FF0415 1FL0402 1FL0423 1GP0405 1HA0442 1HA0450 1HA0451 1HA0443 1HA0452 1HA0453 1NP0442 1NP0454 1NP0455 1RC0470 1RC0471 All All All All All All All All All All All All All All All All All All All 1RC0472 All 1WC0412 1LN0407 1LN0408 All All All Hail Guard Kit Hail Guard Kit Flue Exhaust Extension Kit 2" only Metal Filter Frame Kit 2" only Metal Filter Frame Kit Permanent 2" only Filter Kit Includes (4) Four Filters) Permanent 2" only Filter Kit (Includes (4) four Filters) Gas Piping Kit High Altitude Kit for Natural Gas High Altitude Kit for Natural Gas High Altitude Kit for Natural Gas High Altitude Kit for Propane High Altitude Kit for Propane High Altitude Kit for Propane Propane Conversion Kit Propane Conversion Kit Propane Conversion Kit Roof Curb, 8" Height Roof Curb, 14" Height Roof Curb, Transition (7.5 T thru 12.5T Sunline to Predator 312T) Wooden Crate for extra protection during shipping and handling Low NOx Kit Low NOx Kit 10 WHERE USED All Cabinets (Electric / Electric Models), 50” Tall Standard Cabinets (Gas / Electric Models), 50" Tall Standard Cabinets (Electric / Electric Models), 42” Tall Cabinets (Gas / Electric Models), 42" Tall Cabinets All Tall (50") Standard Cabinets, (Excludes 12.5T "V" cabinets) All Short (42") Standard Cabinets All Cabinets All Tall 50" Cabinets All Tall 42" Cabinets All Tall 50" Cabinets All Tall 42" Cabinets All Cabinets All 6 - 12T Cabinets 3 - 5T (80, 120 & 160 MBH Input) 3 - 4T (60 MBH Input) All 6 - 12T Cabinets 3 - 5T (80, 120 & 160 MBH Input) 3 - 4T (60 MBH Input) All 6 - 12T Cabinets 3 - 5T (80, 120 & 160 MBH Input) 3 - 4T (60 MBH Input) All Cabinets All Cabinets All Cabinets Standard Cabinets Only (not applicable to units 119" in length) 3 - 5T (80, 120 & 160 MBH Input) 3 - 5T (60 MBH Input) Johnson Controls Unitary Products 528150-YTG-T-0514 Accessories (Continued) Field Installed Accessories - Electric Heat MODEL 2TP04520925 2TP04520946 2TP04520958 2TP04531825 2TP04531846 2TP04521858 2TP04532425 2TP04532446 2TP04522458 2TP04533625 2TP04533646 2TP04523658 2TP04525425 2TP04525446 2TP04525458 2TP04540925 2TP04540946 2TP04540958 2TP04541825 2TP04541846 2TP04541858 2TP04542425 2TP04542446 2TP04542458 2TP04543625 2TP04543646 2TP04543658 2TP04510325 2TP04510346 2TP04510625 2TP04510646 2TP04510825 2TP04510846 2TP04510858 2TP04511525 2TP04511546 2TP04511558 2TP04512025 2TP04512046 2TP04512058 2TP04512325 2TP04512346 2TP04512358 VOLTAGE 230 460 575 230 460 575 230 460 575 230 460 575 230 460 575 230 460 575 230 460 575 230 460 575 230 460 575 230 460 230 460 230 460 575 230 460 575 230 460 575 230 460 575 DESCRIPTION WHERE USED 9kW Electric Heat All 50" Cabinet 6.5 and 8.5 Ton Models 18kW Electric Heat All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models 24kW Electric Heat All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models 36kW Electric Heat All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models 54kW Electric Heat All 50" 10 and 12.5 Ton Models 9kW Electric Heat All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models 18kW Electric Heat All 42" 6.5, 7.5 and 8.5 Ton Models 24kW Electric Heat All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models 36kW Electric Heat All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models 3kW Electric Heat All 42" Cabinet 3 Ton Models 6kW Electric Heat All 42" Cabinet 3, 4 and 5 Ton Models 9kW Electric Heat All 42" Cabinet 3, 4 and 5 Ton Models 15kW Electric Heat All 42" Cabinet 3, 4 and 5 Ton Models 20kW Electric Heat All 42" 4 and 5 Ton Models 24kW Electric Heat All 42" Cabinet 5 Ton Models Johnson Controls Unitary Products 11 528150-YTG-T-0514 Accessories (Continued) Field Installed Accessories - Fresh Air MODEL 1EH0408 1FA0413 1FA0414 1RD0411 2EC04700924 VOLTAGE All All All All All 2EE04708324 All DESCRIPTION Barometric Relief Kit for Power Exhaust, Horizontal Application Manual Outside Air Damper 0-35%, Downflow Manual Outside Air Damper 0-100%, Downflow Barometric Relief Kit for Horizontal Applications Dual Enthalpy Control Downflow Economizer, Slab type for ERV & Downflow Applications, (no Barometric Relief or FA hood) Downflow Economizer, Slab type for ERV & Downflow Applications, (no Barometric Relief or FA hood) All Horizontal Economizer without Barometric Relief 2EE04706024 All Motorized Damper, Downflow without Barometric Relief 2MD04703224 All Motorized Damper, Horizontal 2MD04703724 230 Power Exhaust 230V Downflow or Horizontal 2PE04704706* 460 Power Exhaust 460V Downflow or Horizontal 2PE04704746* 575 Power Exhaust 575V Downflow or Horizontal 2PE04704758* * Must be installed in return Duct on Horizontal Applications and a 1EH0408 is required. 2EE04707524 All WHERE USED All Cabinets All Cabinets All Cabinets All Cabinets All Cabinets All 50" Cabinets All 42" Cabinets All Cabinets All Cabinets All Cabinets All Cabinets All Cabinets All Cabinets Field Installed Accessories - Controls MODEL 2AP0401 2AQ04700324B 2AQ04700424C 2DF0402 2DH04700024 2SD04700624 2SD04700824 2SD04700924 2SD04701024 VOLTAGE All All All All All All All All All DESCRIPTION Air Proving Switch CO² Space Accessory CO² Unit Accessory Dirty Air Switch Humidistat WHERE USED All Units All Units All Units All Units All Units All Gen 4 or older units with 2" Filter only capable Cabinets All Gen 5 units with 2" & 4" Filters All Gen 5 units with 2" & 4" Filters All Gen 5 units with 2" & 4" Filters Smoke Detector for Supply or Return Smoke Detector for Supply Smoke Detector for Return Smoke Detector for Supply and Return Field Installed Accessories - Electrical MODEL 2BC04700106 2BC04700151 2BC04700154 2LA04704632 VOLTAGE 230 460 575 All DESCRIPTION Gas heat kit, -60ºF Gas heat kit, -60ºF Gas heat kit, -60ºF Low Ambient Kit Guide Specifications GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 3 through 12-1/2 ton models. All 6-1/2 through 12-1/2 ton units have two compressors with independent R410A refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged with R-410A, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, cooling with gas heat, reheat only, reheat with electric heat and reheat 12 WHERE USED All Units All Units All Units All 3 - 10T units (excludes 12.5T "V" cabinets) with gas heat. Electric heaters are available as factory-installed options or field-installed accessories. DESCRIPTION Units shall be factory assembled, single package, (Elec/Elec, Gas/ Elec), designed for outdoor installation. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be factory wired, piped and charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non-chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM-B117 Johnson Controls Unitary Products 528150-YTG-T-0514 standards. Indoor blower sections shall be insulated with up to 1” thick insulation coated on the airside. Either aluminum foil faced or elastometric rubber insulation shall be used in the unit’s compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with toolless access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Disposable 2” filters shall be furnished as standard and be accessible through hinged access door. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating bypass of the coils. Condensate pan shall be slide out design, constructed of a non corrosive material, internally sloped and conforming to ASHRAE 62-B9 standards. Condensate connection shall be a minimum of ¾” I.D. female and be rigid mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Job site selected brake horsepower shall not exceed the motors nameplate horsepower rating plus the service factor. Units shall be designed to operate within the service factor. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro-Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed-orifice expansion devices. or thermally operated b. Solid core filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The 6-1/2 through 12-1/2 ton unit shall have two independent refrigerant circuits, equally split in 50% capacity increments. Unit Controls: a. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: • Loss-of-charge/Low-pressure switch. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or – 10% of the unit nameplate voltage. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, drawthru design. Johnson Controls Unitary Products • High-pressure switch. • Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light-emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. c. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. d. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. e. Unit control board shall have on-board diagnostics and fault code display. f. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0 ºF. g. Control board shall monitor each refrigerant safety switch independently. h. Control board shall retain last 5 fault codes in nonvolatile memory, which will not be lost in the event of a power loss. GAS HEATING SECTION (IF EQUIPPED) Heat exchanger and exhaust system shall be constructed of aluminized steel and shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. The heat exchanger shall 13 528150-YTG-T-0514 be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminum-coated steel. All gas piping shall enter the unit cabinet at a single location, through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary and auxiliary high-temperature limit switches. b. Induced draft pressure sensor. c. Flame roll out switch (manual reset). d. Flame proving controls. e. All two stage gas units shall have two independent stages of capacity (70% or 75% 1st stage, 100% 2nd stage) 3 through 5 ton and (60% 1st stage, 100% 2nd stage) 6-1/2 through 12-1/2 ton. ELECTRIC HEATING SECTION (IF EQUIPPED) An electric heating section, with nickel chromium elements, shall be provided in a range of 3 thru 54KW. The heating section shall have a primary limit control(s) (automatic reset) to prevent the heating element system from operating at an excessive temperature. The Heating Section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125 ºF outdoor temperature, exceeding maximum load criteria of AHRI Standard 340/360. The compressor, with standard controls, shall be capable of operation down to 0 ºF outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up. (Gas heat only) ELECTRICAL REQUIREMENTS - All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES - Compressor – 5 Years, Heat Exchanger – 10 Years, Elect. Heat Elem. – 5 Years, Parts – 1 Year OPTIONAL OUTDOOR AIR (Shall be made available by either/ or): • ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER - Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall be designed to meet ASHRAE 90.12010, AMCA 511 Class 1A damper, and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/sq. ft. at 1" of static pressure. During economizer operation, a 14 mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Available with barometric relief and power exhaust. • MOTORIZED OUTDOOR AIR DAMPERS - Outdoor and return air dampers that are interlocked and positioned by a 2- position, spring-return damper actuator. A unitmounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is deenergized. Dampers shall fully close on power loss. ADDITIONAL FACTORY INSTALLED OPTIONS • ALTERNATE INDOOR BLOWER MOTOR – For applications with high restrictions, units are available with optional indoor blower motors that provide higher static output and/or higher airflow. • VARIABLE AIR VOLUME (VAV) - The VAV option using a variable frequency drive (VFD) shall be available on 6-1/2 through 12-1/2 ton models for applications requiring a constant supply-duct static pressure. Units equipped for VAV shall be controlled by a duct pressure transducer with a 0 - 5" WC pressure range. The pressure transducer shall provide a 0 - 5 VDC output signal to a VAV control board which, in turn shall provide a 2 - 10 VDC speed reference signal to the VFD. The VAV control board shall operate using factory-installed Supply Air, Return Air and Outside Air Temperature Sensors with a nominal resistance of 10,000 Ohms. Units equipped with VFD's shall have factory-installed manual bypass as an option. • CONVENIENCE OUTLET (POWERED/NON-POWERED)– Unit can be provided with an optional 120VAC GFCI outlet with cover on the corner of the unit housing the compressors. • ELECTRIC HEAT - Electric Heaters range from 3kW to 54kW and are available in all the voltage options of the base unit. • PHASE MONITOR - Designed to prevent damage in outof-phase condition. • COIL GUARD - Designed to prevent condenser coil damage. • BAS CONTROLS - Include supply air sensor, return air sensor, dirty filter indicator and air proving switch. • DIRTY FILTER SWITCH – This kit includes a differential pressure switch that energizes the fault light on the unit Johnson Controls Unitary Products 528150-YTG-T-0514 thermostat, indicating that there is an abnormally highpressure drop across the filters. • BREAKER – An HACR breaker can be factory installed on gas heat units or cooling units with electric heat. • DISCONNECT SWITCH - A disconnect can be factory installed on a cooling only units sized for the largest electric heat available. • BAROMETRIC RELIEF DAMPER – (Unit mounted – Downflow, Duct Mounted – Horizontal) – Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit during economizer operation. • PROPANE CONVERSION KIT – Contains new orifices and gas valve springs to convert from natural to L.P. gas. • STAINLESS STEEL HEAT EXCHANGER – For applications in a corrosive environment, this option provides a full stainless steel heat exchanger assembly. • -60ºF GAS HEAT KIT – Provides an electric heat kit for the gas compartment for use in extreme low ambient conditions. • SMOKE DETECTOR – A smoke detector can be factory mounted and wired in the supply and/or return air compartments. • ECONOMIZER (Downflow and Horizontal flow) OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • POWER EXHAUST – (Unit mount – Downflow, Duct mount – Horizontal flow) • DUAL ENTHALPY KIT - Provides a second input to economizer to monitor return air. • ROOF CURB - 14” and 8” high, full perimeter knockdown curb, with hinged design for quick assembly. Johnson Controls Unitary Products 15 528150-YTG-T-0514 Physical Data ZH037-061 Single Stage Gas Physical Data Models Component ZH037 ZH049 ZH061 3.0 4.0 5.0 Gross Capacity @ AHRI A point (MBh) 37000 50000 61000 AHRI net capacity (MBh) 36000 48000 58000 11.8 11.8 11.8 SEER 14 14 14 IPLV - - - CFM 1200 1600 2000 System power (KW) 3.05 4.07 4.90 R-410A R-410A R-410A System 1 7-4 6-14 7-12 System 2 - - - Nominal Tonnage AHRI COOLING PERFORMANCE EER Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model A05 A07 A09 A05 A07 A09 A07 A09 A13 Heat input (K Btu) 60 80 120 60 80 120 80 120 160 Heat output (K Btu) 49 65 97 49 65 97 65 97 129 - - - - 81 81.5 81 81 81 80.5 AFUE % - Steady state efficiency (%) 81.5 81 81 - No. burners 4 4 6 4 4 6 4 6 8 No. stages 1 1 1 1 1 1 1 1 1 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) 20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F 235°F 200°F 255°F 235°F 200°F 255°F 200°F 245°F 240°F 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DIMENSIONS (inches) Length 89 89 89 Width 59 59 59 Height 42 42 42 723 763 864 Recip Recip Recip OPERATING WT. (lbs.) COMPRESSORS Type Quantity Unit Capacity Steps (%) 1 1 1 100 100 100 21.1 CONDENSER COIL DATA Face area (Sq. Ft.) 11.9 18.5 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in./MM) Circuitry Type 1/25 .71/18 .71/18 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 10.6 EVAPORATOR COIL DATA Face area (Sq. Ft.) 8 8 Rows 3 3 3 Fins per inch 15 15 15 Tube diameter 0.375 0.375 0.375 Refrigerant control TXV TXV TXV 16 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH037-061 Single Stage Gas Physical Data (Continued) Models Component Nominal Tonnage ZH037 ZH049 ZH061 3.0 4.0 5.0 1 1 2 CONDENSER FAN DATA Quantity of fans Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct 1 1 2 1/3 1/3 1/3 Quantity of motors Motor HP each No. speeds 1 1 1 RPM 850 850 850 Total CFM 3300 3700 6700 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 12 x 9 12 x 9 12 x 9 Centrifugal Centrifugal Centrifugal Motor Sheave 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 Blower Sheave AK69 AK69 AK56 AK56 AK61 AK74 Belt A47 A47 A47 A47 A47 A51 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 Frame size FILTERS Quantity - Size 4 - (24 x 16 x 2)1,2 3 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)1,2 3 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)1,2 4 - (24 x 16 x 4)3 1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 2. 2 In. Pleated, Optional, MERV 7. 3. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 17 528150-YTG-T-0514 ZH037-061 Two Stage Gas Physical Data Models Component ZH037 ZH049 ZH061 3.0 4.0 5.0 Gross Capacity @ AHRI A point (MBh) 37000 50000 61000 AHRI net capacity (MBh) 36000 48000 58000 11.8 11.8 11.8 SEER 14 14 14 IPLV - - - CFM 1200 1600 2000 System power (KW) 3.05 4.07 4.90 R-410A R-410A R-410A System 1 7-4 6-14 7-12 System 2 - - - Nominal Tonnage AHRI COOLING PERFORMANCE EER Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model N05 N07 N09 N05 N07 N09 N07 N09 N13 Heat input (K Btu) 60 80 120 60 80 120 80 120 160 Heat output (K Btu) 49 65 97 49 65 97 65 97 129 - - - - 81 81.5 81 81 81 80.5 AFUE % - Steady state efficiency (%) 81.5 81 81 - No. burners 4 4 6 4 4 6 4 6 8 No. stages 21 22 22 21 22 22 22 22 22 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) 20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F 235°F 200°F 255°F 235°F 200°F 255°F 200°F 245°F 240°F 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DIMENSIONS (inches) Length 89 89 89 Width 59 59 59 Height 42 42 42 723 763 864 Recip Recip Recip OPERATING WT. (lbs.) COMPRESSORS Type Quantity Unit Capacity Steps (%) 1 1 1 100 100 100 21.1 CONDENSER COIL DATA Face area (Sq. Ft.) 11.9 18.5 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in./MM) Circuitry Type 1/25 .71/18 .71/18 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 10.6 EVAPORATOR COIL DATA Face area (Sq. Ft.) 8 8 Rows 3 3 3 Fins per inch 15 15 15 Tube diameter 0.375 0.375 0.375 Refrigerant control TXV TXV TXV 18 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH037-061 Two Stage Gas Physical Data (Continued) Models Component Nominal Tonnage ZH037 ZH049 ZH061 3.0 4.0 5.0 1 1 2 CONDENSER FAN DATA Quantity of fans Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct 1 1 2 1/3 1/3 1/3 Quantity of motors Motor HP each No. speeds 1 1 1 RPM 850 850 850 Total CFM 3300 3700 6700 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 12 x 9 12 x 9 12 x 9 Centrifugal Centrifugal Centrifugal Motor Sheave 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 Blower Sheave AK69 AK69 AK56 AK56 AK61 AK74 Belt A47 A47 A47 A47 A47 A51 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 Frame size FILTERS Quantity - Size 1. 2. 3. 4. 5. 4 - (24 x 16 x 2)3,4 5 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)3,4 5 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)3,4 4 - (24 x 16 x 4)5 1st Stage Capacity is 75% of Full Capacity. 1st Stage Capacity is 70% of Full Capacity. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 2 In. Pleated, Optional, MERV 7. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 19 528150-YTG-T-0514 ZH078-150 Physical Data Models Component ZH078 ZH090 ZH102 ZH120 ZH150 6.5 7.5 8.5 10 12.5 Gross Capacity @ AHRI A point (Btu) 81000 93000 107000 125000 156000 AHRI net capacity (Btu) 78000 90000 102000 120000 150000 11.71/11.52 11.71/11.52 11.71/11.52 11.7 11.71/11.52 Nominal Tonnage AHRI COOLING PERFORMANCE EER SEER - - - - - IEER 12.81/12.62 12.81/12.62 12.81/12.62 12 12.81/12.62 IPLV 13.7 13 13.5 12.9 14.1 CFM 2600 2700 3400 4000 3750 System power (KW) 6.69 7.70 9.0 10.40 12.80 R-410A R-410A R-410A R-410A R-410A System 1 7-0 6-0 7-6 8-8 8-2 System 2 6-0 6-0 7-2 7-7 8-2 Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model 10 15 10 15 10 15 15 20 15 20 Heat input (K Btu) 120 180 120 180 120 180 180 240 180 240 Heat output (K Btu) 96 144 96 144 96 144 144 192 144 192 - - - - - - - - - - 80 80 80 80 80 80 80 80 80 80 AFUE % Steady state efficiency (%) No. burners 4 6 4 6 4 6 6 8 6 8 No. stages 23 23 23 23 23 23 23 23 23 23 20-50 35-65 15-45 30-60 10-40 25-55 20-50 35-65 10-40 25-55 Gas Limit Setting (ºF) 165 165 165 165 215 195 195 160 195 160 Gas piping connection (in.) 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Temperature Rise Range (ºF) DIMENSIONS (inches) Length 89 89 89 89 Width 59 59 59 59 59 Height 42 42 50-3/4 50-3/4 50-3/4 910 910 1047 1090 1280 Recip Recip Recip Scroll Scroll 2 2 2 2 2 50 / 100 50 / 100 50 / 100 50 / 100 50 / 100 47.5 OPERATING WT. (lbs.) 119-1/2 COMPRESSORS Type Quantity Unit Capacity Steps (%) CONDENSER COIL DATA Face area (Sq. Ft.) 23.8 23.8 29.0 29.0 Rows 1 1 1 1 1 Fins per inch 23 23 23 23 23 1/25 1/25 1/25 1/25 .71/18 Tube diameter (in./MM) Circuitry Type 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.) 10.6 10.6 13.2 13.2 Rows 3 3 3 4 13.2 4 Fins per inch 15 15 15 15 15 Tube diameter 0.375 0.375 0.375 0.375 0.375 Circuitry Type Intertwined Intertwined Intertwined Intertwined Intertwined TXV TXV TXV TXV TXV Refrigerant control 20 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078-150 Physical Data (Continued) Models Component ZH078 ZH090 ZH102 ZH120 ZH150 6.5 7.5 8.5 10 12.5 2 2 2 2 4 Nominal Tonnage CONDENSER FAN DATA Quantity of fans Fan diameter (Inch) 24 24 24 24 24 Type Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct 2 2 2 2 4 1/3 3/4 3/4 3/4 1/3 Quantity of motors Motor HP each No. speeds 1 1 1 1 1 RPM 850 1110 1110 1110 850 Total CFM 6700 8600 9400 9400 14000 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 1 1 12 x 12 12 x 12 15 x 15 15 x 15 15 x 15 Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor Sheave 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 Blower Sheave AK74 AK64 AK74 AK61 AK94 AK74 AK84 AK74 AK74 BK77 Belt A49 A49 A49 A49 A56 A54 A56 A54 A54 BX55 Motor HP each 1-1/2 2 1-1/2 3 2 3 2 3 3 5 RPM 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 56 56 56 184T Frame size FILTERS Quantity - Size 1. 2. 3. 4. 5. 6. 4 - (24 x 16 x 2)4,5 4 - (24 x 16 x 4) 6 4 - (24 x 16 x 2)4,5 4 - (24 x 16 x 4) 6 4 - (24 x 20 x 2)4,5 6 4 - (24 x 20 x 4) 4 - (24 x 20 x 2)4,5 6 4 - (24 x 20 x 4) 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 4)6 Cooling Only Unit Cooling Unit with Gas or Electric Heat 1st Stage 60% of Full Capacity. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3. 2 In. Pleated, Optional, MERV 7. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 21 528150-YTG-T-0514 ZJ037-061 Single Stage Gas Heat Physical Data Models Component ZJ037 ZJ049 ZJ061 3.0 4.0 5.0 Gross Capacity @ AHRI A point (MBh) 37000 50000 62000 AHRI net capacity (MBh) 36000 48000 60000 12.2 12.2 12.2 SEER 15 15 15 IPLV - - - CFM 1300 1600 2000 System power (KW) 2.95 3.95 4.90 R-410A R-410A R-410A System 1 6-12 7-8 8-4 System 2 - - - Nominal Tonnage AHRI COOLING PERFORMANCE EER Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model A05 A07 A09 A05 A07 A09 A07 A09 A13 Heat input (K Btu) 60 80 120 60 80 120 80 120 160 Heat output (K Btu) 49 65 97 49 65 97 65 97 129 - - - - 81 81.5 81 81 81 80.5 AFUE % - Steady state efficiency (%) 81.5 81 81 - No. burners 4 4 6 4 4 6 4 6 8 No. stages 1 1 1 1 1 1 1 1 1 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) 20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F 235°F 200°F 255°F 235°F 200°F 255°F 200°F 245°F 240°F 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DIMENSIONS (inches) Length 89 89 89 Width 59 59 59 Height 42 42 42 740 775 770 Recip Recip Recip OPERATING WT. (lbs.) COMPRESSORS Type Quantity Unit Capacity Steps (%) 1 1 1 100 100 100 23.8 CONDENSER COIL DATA Face area (Sq. Ft.) 18.5 23.8 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in./MM) Circuitry Type .71/18 .71/18 .71/18 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 10.5 EVAPORATOR COIL DATA Face area (Sq. Ft.) 7.9 10.5 Rows 3 3 3 Fins per inch 15 15 15 Tube diameter 0.375 0.375 0.375 Refrigerant control TXV TXV TXV 22 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ037-061 Single Stage Gas Heat Physical Data (Continued) Models Component Nominal Tonnage ZJ037 ZJ049 ZJ061 3.0 4.0 5.0 1 1 2 CONDENSER FAN DATA Quantity of fans Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct 1 1 2 1/3 1/3 1/3 Quantity of motors Motor HP each No. speeds 1 1 1 RPM 850 850 850 Total CFM 3300 3700 6300 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 12 x 9 12 x 9 12 x 9 Centrifugal Centrifugal Centrifugal Motor Sheave 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 Blower Sheave AK69 AK69 AK56 AK56 AK61 AK74 Belt A47 A47 A47 A47 A47 A51 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 Frame size FILTERS Quantity - Size 4 - (24 x 16 x 2)1,2 3 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)1,2 3 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)1,2 4 - (24 x 16 x 4)3 1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 2. 2 In. Pleated, Optional, MERV 7. 3. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 23 528150-YTG-T-0514 ZJ037-061 Two Stage Gas Heat Physical Data Models Component ZJ037 ZJ049 ZJ061 3.0 4.0 5.0 Gross Capacity @ AHRI A point (MBh) 37000 50000 62000 AHRI net capacity (MBh) 36000 48000 60000 12.2 12.2 12.2 SEER 15 15 15 IPLV - - - CFM 1300 1600 2000 System power (KW) 2.95 3.95 4.90 R-410A R-410A R-410A System 1 6-12 7-8 8-4 System 2 - - - Nominal Tonnage AHRI COOLING PERFORMANCE EER Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model N05 N07 N09 N05 N07 N09 N07 N09 N13 Heat input (K Btu) 60 80 120 60 80 120 80 120 160 Heat output (K Btu) 49 65 97 49 65 97 65 97 129 - - - - 81 81.5 81 81 81 80.5 AFUE % - Steady state efficiency (%) 81.5 81 81 - No. burners 4 4 6 4 4 6 4 6 8 No. stages 21 22 22 21 22 22 22 22 22 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) 20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F 235°F 200°F 255°F 235°F 200°F 255°F 200°F 245°F 240°F 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DIMENSIONS (inches) Length 89 89 89 Width 59 59 59 Height 42 42 42 740 775 770 Recip Recip Recip OPERATING WT. (lbs.) COMPRESSORS Type Quantity Unit Capacity Steps (%) 1 1 1 100 100 100 23.8 CONDENSER COIL DATA Face area (Sq. Ft.) 18.5 23.8 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in./MM) Circuitry Type .71/18 .71/18 .71/18 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 10.5 EVAPORATOR COIL DATA Face area (Sq. Ft.) 7.9 23.8 Rows 3 3 3 Fins per inch 15 15 15 Tube diameter 0.375 0.375 0.375 Refrigerant control TXV TXV TXV 24 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ037-061 Two Stage Gas Heat Physical Data (Continued) Models Component Nominal Tonnage ZJ037 ZJ049 ZJ061 3.0 4.0 5.0 1 1 2 CONDENSER FAN DATA Quantity of fans Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct 1 1 2 1/3 1/3 1/3 Quantity of motors Motor HP each No. speeds 1 1 1 RPM 850 850 850 Total CFM 3300 3700 6300 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 12 x 9 12 x 9 12 x 9 Centrifugal Centrifugal Centrifugal Motor Sheave 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 Blower Sheave AK69 AK69 AK56 AK56 AK61 AK74 Belt A47 A47 A47 A47 A47 A51 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 Frame size FILTERS Quantity - Size 1. 2. 3. 4. 5. 4 - (24 x 16 x 2)3,4 5 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)3,4 5 4 - (24 x 16 x 4) 4 - (24 x 16 x 2)3,4 4 - (24 x 16 x 4)5 1st Stage Capacity is 75% of Full Capacity. 1st Stage Capacity is 70% of Full Capacity. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 2 In. Pleated, Optional, MERV 7. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 25 528150-YTG-T-0514 ZJ078-150 Physical Data Models Component ZJ078 ZJ090 ZJ102 ZJ120 ZJ150 6.5 7.5 8.5 10 12.5 Gross Capacity @ AHRI A point (Btu) 80000 93000 106000 124000 154000 AHRI net capacity (Btu) 78000 90000 102000 120000 150000 12.21/12.02 12.21/12.02 12.21/12.02 12.0 12.0 SEER - - - - - IEER 14.0 13.1 12.2 12.8 13 IPLV 14.9 14.18 13.6 13.4 14.1 CFM 2600 2400 2800 3400 3500 Nominal Tonnage AHRI COOLING PERFORMANCE EER System power (KW) 6.40 7.38 8.30 9.80 12.50 R-410A R-410A R-410A R-410A R-410A System 1 5-10 7-12 8-8 7-14 10-8 System 2 5-12 7-10 8-12 7-14 9-12 Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model 10 15 10 15 10 15 15 20 15 20 Heat input (K Btu) 120 180 120 180 120 180 180 240 180 240 Heat output (K Btu) 96 144 96 144 96 144 144 192 144 192 - - - - - - - - - - 80 80 80 80 80 80 80 80 80 80 AFUE % Steady state efficiency (%) No. burners 4 6 4 6 4 6 6 8 6 8 No. stages 23 23 23 23 23 23 23 23 23 23 20-50 35-65 15-45 30-60 10-40 25-55 20-50 35-65 10-40 25-55 Gas Limit Setting (ºF) 165 165 165 165 215 195 195 160 195 160 Gas piping connection (in.) 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Temperature Rise Range (ºF) DIMENSIONS (inches) Length 89 89 89 89 Width 59 59 59 59 59 Height 50-3/4 50-3/4 50-3/4 50-3/4 50-3/4 1030 1050 1060 1070 1280 Recip Recip Recip Scroll Scroll 2 2 2 2 2 50 / 100 50 / 100 50 / 100 50 / 100 50 / 100 47.5 OPERATING WT. (lbs.) 119-1/2 COMPRESSORS Type Quantity Unit Capacity Steps (%) CONDENSER COIL DATA Face area (Sq. Ft.) 29.0 23.8 29.0 29.0 Rows 1 1 1 1 1 Fins per inch 23 23 23 23 23 .71/18 1/25 1/25 1/25 .71/18 Tube diameter (in./MM) Circuitry Type 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.) 13.2 13.2 13.2 13.2 Rows 3 4 4 4 13.2 4 Fins per inch 15 15 15 15 15 Tube diameter 0.375 0.375 0.375 0.375 0.375 Circuitry Type Intertwined Intertwined Intertwined Intertwined Intertwined TXV TXV TXV TXV TXV Refrigerant control 26 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078-150 Physical Data (Continued) Models Component ZJ078 ZJ090 ZJ102 ZJ120 ZJ150 6.5 7.5 8.5 10 12.5 2 2 2 2 4 Nominal Tonnage CONDENSER FAN DATA Quantity of fans Fan diameter (Inch) 24 24 24 24 24 Type Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct 2 2 2 2 4 1/3 3/4 3/4 3/4 1/3 Quantity of motors Motor HP each No. speeds 1 1 1 1 1 RPM 850 1110 1110 1110 850 Total CFM 7400 8000 9000 9400 14000 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 1 1 15 x 15 15 x 15 15 x 15 15 x 15 15 x 15 Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor Sheave 1VL40 1VM50 1VL40 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 Blower Sheave AK74 AK74 AK69 AK69 AK89 AK74 AK84 AK74 AK74 BK77 Belt A53 A54 A52 A54 A56 A54 A56 A54 A54 BX55 Motor HP each 1-1/2 2 1-1/2 3 2 3 2 3 3 5 RPM 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 56 56 56 184T Frame size FILTERS Quantity - Size 1. 2. 3. 4. 5. 6. 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 4) 6 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 4) 6 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 4) 6 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 4) 6 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 4)6 Cooling Only Unit Cooling Unit with Gas or Electric Heat 1st Stage 60% of Full Capacity. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3. 2 In. Pleated, Optional, MERV 7. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 27 528150-YTG-T-0514 ZR037-061 Single Stage Gas Heat Physical Data Models Component Nominal Tonnage ZR037 ZR049 ZR061 3 4 5 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 36500 49000 62000 AHRI net capacity (Btu) 35500 47500 60000 12.2 12.2 12.2 15 15 14.7 EER SEER IPLV - - - CFM 1200 1600 2000 System power (KW) 2.88 3.32 4.83 R-410A R-410A R-410A System 1 12-8 12-0 11-0 System 2 - - - Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model A05 A07 A09 A05 A07 A09 A07 A09 A13 Heat input (K Btu) 60 80 120 60 80 120 80 120 160 Heat output (K Btu) 49 65 97 49 65 97 65 97 129 - - - - 81 81.5 81 81 81 80.5 AFUE % - Steady state efficiency (%) 81.5 81 81 - No. burners 4 4 6 4 4 6 4 6 8 No. stages 1 1 1 1 1 1 1 1 1 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) 20-50°F 25-65°F 35-80°F 20-50°F 25-65°F 35-80°F 25-65°F 35-80°F 45-75°F 200°F 235°F 290°F 200°F 235°F 290°F 235°F 290°F 240°F 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DIMENSIONS (inches) Length 89 89 Width 59 59 59 Height 42 42 42 867 880 867 Recip Recip Recip 1 1 1 100 100 100 11.9 OPERATING WT. (lbs.) 89 COMPRESSORS Type Quantity Unit Capacity Steps (%) CONDENSER COIL DATA Face area (Sq. Ft.) 11.9 11.9 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in./MM) Circuitry Type .98/25 .98/25 .71/18 - .98/25 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 10.56 EVAPORATOR COIL DATA Face area (Sq. Ft.) 10.56 10.56 Rows 3 3 4 Fins per inch 15 15 12 Tube diameter 0.375 0.375 0.375 Refrigerant control TXV TXV TXV 8.9 REHEAT COIL DATA Face area (Sq. Ft.) 8.9 8.9 Rows 2 2 2 Fins per inch 15 15 15 Tube diameter Refrigerant control 28 0.375 0.375 0.375 Solenoid Solenoid Solenoid Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037-061 Single Stage Gas Heat Physical Data (Continued) Models Component Nominal Tonnage ZR037 ZR049 ZR061 3 4 5 CONDENSER FAN DATA Quantity of fans 1 2 2 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct Quantity of motors 1 2 2 Motor HP each 1/3 1/3 1/3 No. speeds Var. Var. Var. RPM (max.) 850 850 850 Total CFM 3500 7000 7000 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 12 x 9 12 x 9 12 x 9 Centrifugal Centrifugal Centrifugal Motor Sheave 1VP34 1VL44 1VP34 1VL44 1VP34 1VL44 Blower Sheave AK61 AK59 AK61 AK59 AK61 AK59 Belt A47 A47 A47 A47 A47 A47 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 Frame size FILTERS Quantity - Size 4 - (25 x 16 x 2)1, 2 4 - (25 x 16 x 2) 1, 2 4 - (25 x 16 x 2)1, 2 4 - (25 x 16 x 4) 3 4 - (25 x 16 x 4) 3 4 - (25 x 16 x 4) 3 1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 2. 2 In. Pleated, Optional, MERV 7. 3. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 29 528150-YTG-T-0514 ZR037-061 Two Stage Gas Heat Physical Data Models Component Nominal Tonnage ZR037 ZR049 ZR061 3 4 5 AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point (Btu) 36500 49000 62000 AHRI net capacity (Btu) 35500 47500 60000 12.2 12.2 12.2 15 15 14.7 EER SEER IPLV - - - CFM 1200 1600 System power (KW) 2.88 3.32 4.83 R-410A R-410A R-410A Refrigerant type 2000 Refrigerant charge (lb-oz) System 1 12-8 System 2 12-0 - 11-0 - - AHRI HEATING PERFORMANCE Heating model N05 N07 N09 N05 N07 N09 N07 N09 N13 Heat input (K Btu) 60 80 120 60 80 120 80 120 160 Heat output (K Btu) 49 65 97 49 65 97 65 97 129 - - - - 81 81.5 81 81 81 80.5 AFUE % - Steady state efficiency (%) 81.5 81 81 - No. burners 4 4 6 4 4 6 4 6 8 No. stages 21 22 22 21 22 22 22 22 22 20-50°F 25-65°F 35-80°F 20-50°F 200°F 235°F 290°F 200°F 235°F 290°F 235°F 290°F 240°F 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Temperature Rise Range (ºF) Gas Limit Setting (ºF) Gas piping connection (in.) 25-65°F 35-80°F 25-65°F 35-80°F 45-75°F DIMENSIONS (inches) Length 89 89 Width 59 59 59 Height 42 42 42 867 880 867 Recip Recip Recip 1 1 1 100 100 100 11.9 OPERATING WT. (lbs.) 89 COMPRESSORS Type Quantity Unit Capacity Steps (%) CONDENSER COIL DATA Face area (Sq. Ft.) 11.9 11.9 Rows 1 1 1 Fins per inch 23 23 23 Tube diameter (in./MM) Circuitry Type .98/25 .98/25 .71/18 - .98/25 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 10.56 EVAPORATOR COIL DATA Face area (Sq. Ft.) 10.56 10.56 Rows 3 3 4 Fins per inch 15 15 12 Tube diameter 0.375 0.375 0.375 Refrigerant control TXV TXV TXV 8.9 REHEAT COIL DATA Face area (Sq. Ft.) 8.9 8.9 Rows 2 2 2 Fins per inch 15 15 15 Tube diameter Refrigerant control 30 0.375 0.375 0.375 Solenoid Solenoid Solenoid Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037-061 Two Stage Gas Heat Physical Data (Continued) Models Component Nominal Tonnage ZR037 ZR049 ZR061 3 4 5 CONDENSER FAN DATA Quantity of fans 1 2 2 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct Quantity of motors 1 2 2 Motor HP each 1/3 1/3 1/3 No. speeds Var. Var. Var. RPM 850 850 850 Total CFM 3500 7000 7000 BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 12 x 9 12 x 9 12 x 9 Centrifugal Centrifugal Centrifugal Motor Sheave 1VP34 1VL44 1VP34 1VL44 1VP34 1VL44 Blower Sheave AK61 AK59 AK61 AK59 AK61 AK59 Belt A47 A47 A47 A47 A47 A47 Motor HP each 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 RPM 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 Frame size FILTERS Quantity - Size 4 - (25 x 16 x 2)3,4 4 - (25 x 16 x 4)5 4 - (25 x 16 x 2)3,4 4 - (25 x 16 x 4)5 4 - (25 x 16 x 2)3,4 4 - (25 x 16 x 4)5 1. 1st Stage Capacity is 75% of Full Capacity. 2. 1st Stage Capacity is 70% of Full Capacity. 3. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 4. 2 In. Pleated, Optional, MERV 7. 5. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 31 528150-YTG-T-0514 ZR078-150 Physical Data Models Component ZR078 ZR090 ZR102 ZR120 ZR150 6.5 7.5 8.5 10 12.5 Gross Capacity @ AHRI A point (Mbh) 80000 90000 105000 124000 157000 AHRI net capacity (Mbh) Nominal Tonnage AHRI COOLING PERFORMANCE 78000 87000 102000 120000 150000 EER 11.2 11.2 11.2 11.2 11.2 IEER 12.51/12.32 11.5 12.2 11.3 11.0 IPLV 13.0 CFM 2200 2775 3350 3750 4450 System power (KW) 6.96 7.77 9.11 10.71 13.39 R-410A R-410A R-410A R-410A R-410A System 1 9-0 6-12 11-10 8-11 20-0 System 2 5-8 6-0 10-3 7-8 19-0 Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model 10 15 10 15 10 15 15 20 15 20 Heat input (K Btu) 120 180 120 180 120 180 180 240 180 240 Heat output (K Btu) 96 144 96 144 96 144 144 192 144 192 - - - - - - - - - - 80 80 80 80 80 80 80 80 80 80 AFUE % Steady state efficiency (%) No. burners 4 6 4 6 4 6 6 8 6 8 No. stages 23 23 23 23 23 23 23 23 23 23 Temperature Rise Range (ºF) 20-50 35-65 15-45 30-60 10-40 25-55 20-50 35-65 10-40 25-55 Gas Limit Setting (ºF) 165 165 165 165 215 195 195 160 195 160 Gas piping connection (in.) 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 DIMENSIONS (inches) Length 89 89 89 89 119-7/16 Width 59 59 59 59 59 Height 42 42 50-3/4 50-3/4 50-3/4 957 965 1200 1200 1465 Scroll Scroll Scroll Scroll Scroll 2 2 2 2 2 50 / 100 50 / 100 50 / 100 50 / 100 50 / 100 Face area (Sq. Ft.) 23.8 23.8 29.0 29.0 47.5 Rows OPERATING WT. (lbs.) COMPRESSORS Type Quantity Unit Capacity Steps (%) CONDENSER COIL DATA 2/1 1 2 1 2 Fins per inch 20 23 20 23 15 Tube diameter (in.) 3/8 - 3/8 - 3/8 - 1/25 - 1/25 - Split-face 2-pass Microchannel Split-face 2-pass Microchannel Split-face 13.2 Tube diameter (in.)/MM Circuitry Type EVAPORATOR COIL DATA Face area (Sq. Ft.) 10.6 10.6 13.2 13.2 Rows 3 3 4 4 4 Fins per inch 15 15 15 15 15 Tube diameter 3/8 3/8 3/8 3/8 3/8 Circuitry Type Split-face Split-face Split-face Split-face Split-face TXV TXV TXV TXV TXV Refrigerant control 32 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078-150 Physical Data (Continued) Models Component ZR078 ZR090 ZR102 ZR120 ZR150 6.5 7.5 8.5 10 12.5 6.66 6.66 10 10 10 Nominal Tonnage REHEAT COIL DATA Face area (Sq. Ft.) Rows 2 2 2 2 2 Fins per inch 13 13 13 13 13 Tube diameter (in.) 3/8 3/8 3/8 3/8 3/8 CONDENSER FAN DATA Quantity of Fans 2 2 2 2 4 Fan diameter (Inch) 24 24 24 24 24 Type Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct Quantity of motors Motor HP each 2 2 2 2 4 1/3 1/3 1/3 1/3 1/3 No. speeds 1 1 1 1 1 850 850 850 850 850 6800 6800 6800 6800 14000 RPM Total CFM BELT DRIVE EVAP FAN DATA Quantity Fan Size (Inch) Type 1 1 1 1 1 12 x 12 12 x 12 15 x 15 15 x 15 15 x 15 Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Motor Sheave 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 Blower Sheave AK74 AK64 AK74 AK61 AK89 AK74 AK84 AK74 AK74 BK77 Belt A49 A49 A49 A49 A56 A54 A56 A54 A54 BX55 Motor HP each 1-1/2 2 1-1/2 3 2 3 2 3 3 5 RPM 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 56 56 56 56 56 56 56 56 56 184T Frame size FILTERS Quantity - Size 1. 2. 3. 4. 5. 6. 4 - (24 x 16 x 2)4,5 4 - (24 x 16 x 2)4,5 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 2)4,5 4 - (24 x 16 x 4)6 4 - (24 x 16 x 4)6 4 - (24 x 20 x 4)6 4 - (24 x 20 x 4)6 4 - (24 x 20 x 4)6 Cooling Only or Cooling with Electric Heat Unit Cooling with Gas Heat Unit 1st Stage 60% of 2nd Stage 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3. 2 In. Pleated, Optional, MERV 7. 4 In. Pleated, Optional, MERV 13. Johnson Controls Unitary Products 33 528150-YTG-T-0514 ZH/ZJ/ZR078-150 Unit Limitations Unit Limitations Size (Tons) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 34 Model ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR Unit Voltage Applied Voltage Outdoor DB Temp Min Max Max (°F) 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 208/230-3-60 187 252 125 460-3-60 432 504 125 575-3-60 540 630 125 Johnson Controls Unitary Products 528150-YTG-T-0514 Capacity Performance ZH037-150 Cooling Capacities ZH037 (3.0 Ton) Air on Evaporator Coil CFM 750 900 1050 1200 1350 1500 750 900 1050 1200 1350 1500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 49.1 44.4 39.6 35.4 51.2 46.2 41.3 36.9 35.4 53.3 48.1 43.0 38.3 36.8 55.4 50.0 44.6 39.8 38.3 50.1 44.7 39.9 38.3 50.1 44.8 39.9 38.4 2.3 2.2 2.2 2.3 2.2 2.2 2.2 2.3 2.3 2.2 2.2 2.2 2.3 2.3 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.3 2.3 20.2 25.1 30.0 35.4 22.9 28.2 33.6 36.9 35.4 25.5 31.4 37.3 38.3 36.8 28.2 34.6 41.0 39.8 38.3 37.2 42.9 39.9 38.3 39.7 44.8 39.9 38.4 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 44.0 39.0 34.1 29.8 45.2 40.1 35.1 30.6 30.9 46.5 41.2 36.0 31.5 31.8 47.7 42.3 37.0 32.3 32.6 42.9 37.5 32.7 33.0 43.4 37.9 33.1 33.5 2.7 2.7 2.7 2.6 2.7 2.7 2.7 2.7 2.7 2.8 2.7 2.7 2.7 2.7 2.8 2.8 2.8 2.7 2.7 2.8 2.7 2.7 2.7 2.8 2.7 2.7 2.7 18.0 22.7 27.4 29.8 20.3 25.4 30.5 30.6 30.9 22.5 28.1 33.7 31.5 31.8 24.7 30.8 36.9 32.3 32.6 33.6 37.4 32.7 33.0 36.3 37.9 33.1 33.5 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 16.8 13.4 46.5 2.5 21.7 18.4 15.0 41.7 2.5 26.6 23.3 19.9 16.5 36.9 2.5 32.8 27.8 24.5 21.1 17.8 32.6 2.5 18.8 14.8 48.2 2.5 24.2 20.2 16.1 43.2 2.5 29.6 25.6 21.5 17.5 38.2 2.5 35.1 30.6 26.5 22.5 18.5 33.7 2.5 35.4 32.4 28.4 24.3 20.3 33.2 2.5 20.8 16.1 49.9 2.5 26.7 22.0 17.3 44.7 2.5 32.6 27.9 23.2 18.5 39.5 2.5 37.5 33.3 28.6 23.9 19.2 34.9 2.5 36.8 35.3 30.6 25.9 21.2 34.3 2.5 22.8 17.5 51.5 2.5 29.2 23.8 18.4 46.2 2.5 35.6 30.2 24.8 19.4 40.8 2.5 39.8 36.1 30.7 25.3 19.9 36.1 2.5 38.3 38.3 32.9 27.5 22.1 35.5 2.5 31.3 25.4 19.5 46.5 2.5 38.1 32.2 26.3 20.4 41.1 2.5 39.9 38.0 32.1 26.3 20.4 36.3 2.5 38.3 38.3 32.4 26.6 20.7 35.7 2.5 33.4 27.0 20.6 46.8 2.5 40.6 34.2 27.8 21.5 41.3 2.5 39.9 39.9 33.6 27.2 20.8 36.5 2.5 38.4 38.4 32.0 25.6 19.2 35.9 2.5 95°F 14.7 11.3 40.2 3.0 19.3 16.0 12.6 35.5 2.9 24.0 20.7 17.3 13.9 30.8 2.9 29.8 24.7 21.4 18.0 14.7 27.0 2.8 16.3 12.4 41.2 3.0 21.5 17.6 13.6 36.4 3.0 26.6 22.7 18.8 14.9 31.5 2.9 30.6 27.2 23.3 19.4 15.4 27.7 2.9 30.9 28.0 24.1 20.2 16.2 28.2 2.9 18.0 13.5 42.2 3.0 23.6 19.1 14.7 37.2 3.0 29.2 24.8 20.3 15.8 32.3 3.0 31.5 29.7 25.2 20.7 16.2 28.3 2.9 31.8 30.5 26.1 21.6 17.1 28.9 2.9 19.7 14.7 43.2 3.1 25.8 20.7 15.7 38.1 3.0 31.8 26.8 21.8 16.7 33.1 3.0 32.3 32.1 27.1 22.0 17.0 29.0 2.9 32.6 33.1 28.0 23.0 17.9 29.6 2.9 27.9 22.3 16.6 38.5 3.0 34.4 28.8 23.2 17.5 33.4 3.0 32.7 32.6 27.0 21.3 15.7 29.3 2.9 33.0 33.3 27.6 22.0 16.4 29.9 2.9 30.1 23.8 17.6 39.0 3.0 37.1 30.8 24.6 18.4 33.8 3.0 33.1 33.1 26.9 20.7 14.4 29.6 2.9 33.5 33.5 27.2 21.0 14.8 30.2 2.9 90 19.1 23.9 28.7 32.6 21.6 26.8 32.1 33.7 33.2 24.0 29.8 35.5 34.9 34.3 26.5 32.7 38.9 36.1 35.5 35.4 40.1 36.3 35.7 38.0 41.3 36.5 35.9 15.8 21.2 26.6 27.0 18.9 23.8 28.7 27.7 28.2 21.9 26.4 30.9 28.3 28.9 24.9 28.9 33.0 29.0 29.6 31.7 33.4 29.3 29.9 34.4 33.8 29.6 30.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 15.7 12.4 20.5 17.2 13.8 25.3 22.0 18.6 15.2 31.3 26.3 22.9 19.6 17.6 13.6 22.8 18.9 14.9 28.1 24.1 20.2 16.2 32.9 28.9 24.9 20.9 33.2 30.2 26.2 22.3 19.4 14.8 25.2 20.6 16.0 30.9 26.3 21.7 17.1 34.5 31.5 26.9 22.3 34.3 32.9 28.3 23.7 21.3 16.1 27.5 22.3 17.1 33.7 28.5 23.3 18.1 36.1 34.1 28.9 23.7 35.5 35.7 30.5 25.2 29.6 23.8 18.1 36.3 30.5 24.7 19.0 36.3 35.3 29.6 23.8 35.7 35.8 30.0 24.3 31.7 25.4 19.1 38.8 32.5 26.2 19.9 36.5 36.5 30.2 23.9 35.9 35.9 29.6 23.3 105°F 13.5 10.2 18.0 14.7 11.4 22.4 19.2 15.9 12.7 27.0 23.2 20.0 16.7 15.0 11.2 20.0 16.2 12.4 24.9 21.1 17.3 13.5 27.7 25.6 21.8 17.9 28.2 26.0 22.2 18.4 16.6 12.3 22.0 17.6 13.3 27.4 23.0 18.7 14.3 28.3 27.9 23.5 19.2 28.9 28.4 24.0 19.7 18.2 13.3 24.0 19.1 14.2 29.9 25.0 20.1 15.1 29.0 30.2 25.3 20.4 29.6 30.7 25.8 20.9 26.2 20.7 15.2 31.6 27.0 21.5 16.0 29.3 29.9 24.4 18.9 29.9 30.5 25.0 19.5 28.3 22.2 16.1 33.4 29.0 22.9 16.8 29.6 29.6 23.6 17.5 30.2 30.2 24.1 18.0 65 16.2 17.0 18.3 17.7 19.2 18.5 20.0 18.0 18.5 17.6 17.0 13.5 14.1 14.6 14.8 15.3 15.5 16.0 13.4 14.0 11.4 11.9 35 528150-YTG-T-0514 ZH037 (3.0 Ton) (Continued) Air on Evaporator Coil CFM 750 900 1050 1200 1350 1500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 36.4 31.9 27.4 24.2 37.2 32.6 28.0 24.7 25.4 37.9 33.2 28.6 25.2 26.0 38.7 33.9 29.1 25.7 26.5 34.2 29.4 25.9 26.7 34.5 29.7 26.2 26.9 3.3 3.2 3.1 3.0 3.3 3.2 3.2 3.1 3.1 3.3 3.2 3.2 3.1 3.1 3.3 3.3 3.2 3.1 3.1 3.3 3.2 3.1 3.1 3.3 3.2 3.2 3.2 13.7 19.7 25.8 24.2 17.4 22.2 26.9 24.7 25.4 21.2 24.6 28.0 25.2 26.0 25.0 27.1 29.1 25.7 26.5 29.8 29.4 25.9 26.7 32.5 29.7 26.2 26.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 12.3 9.1 32.6 3.5 16.6 13.4 10.3 28.4 3.4 20.9 17.7 14.6 11.4 24.1 3.4 24.2 21.7 18.6 15.4 12.3 21.4 3.2 13.8 10.1 33.1 3.6 18.5 14.8 11.1 28.8 3.5 23.2 19.5 15.8 12.1 24.5 3.4 24.7 23.9 20.2 16.5 12.8 21.7 3.3 25.4 24.0 20.3 16.6 12.9 22.7 3.3 15.2 11.0 33.7 3.6 20.4 16.2 11.9 29.2 3.5 25.6 21.3 17.1 12.9 24.8 3.4 25.2 26.1 21.9 17.6 13.4 22.1 3.3 26.0 26.2 22.0 17.7 13.5 23.0 3.3 16.7 11.9 34.2 3.6 22.3 17.5 12.7 29.7 3.5 27.9 23.1 18.3 13.6 25.2 3.4 25.7 28.3 23.5 18.8 14.0 22.4 3.3 26.5 28.4 23.6 18.9 14.1 23.4 3.3 24.4 19.1 13.7 29.9 3.6 28.8 25.2 19.8 14.4 25.4 3.5 25.9 27.2 21.9 16.5 11.2 22.5 3.3 26.7 27.7 22.3 17.0 11.6 23.5 3.4 26.5 20.6 14.7 30.1 3.6 29.7 27.2 21.2 15.3 25.5 3.5 26.2 26.2 20.2 14.3 8.3 22.7 3.4 26.9 26.9 21.0 15.1 9.1 23.7 3.4 90 12.4 18.2 24.1 21.4 16.7 20.6 24.5 21.7 22.7 20.9 22.9 24.8 22.1 23.0 25.2 25.2 25.2 22.4 23.4 27.9 25.4 22.5 23.5 30.1 25.5 22.7 23.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 10.7 8.1 15.2 12.2 9.1 19.3 16.3 13.2 10.2 21.4 21.4 17.2 14.1 12.5 8.9 17.0 13.4 9.8 21.5 17.9 14.4 10.8 21.7 21.7 18.7 15.1 22.7 22.0 18.4 14.8 14.2 9.7 18.8 14.7 10.6 23.7 19.6 15.5 11.4 22.1 22.1 20.2 16.1 23.0 23.0 19.9 15.8 15.9 10.5 20.6 15.9 11.3 25.2 21.3 16.6 12.0 22.4 22.4 21.8 17.1 23.4 23.4 21.5 16.8 22.7 17.4 12.2 25.4 23.3 18.1 12.9 22.5 22.5 19.3 14.1 23.5 23.5 19.7 14.4 24.8 19.0 13.2 25.5 25.4 19.6 13.8 22.7 22.7 16.9 11.1 23.7 23.7 17.9 12.1 65 11.1 11.5 11.3 12.0 11.7 12.5 12.2 8.9 9.2 5.3 6.3 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 36 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH049 (4.0 Ton) Air on Evaporator Coil CFM 1000 1200 1400 1600 1800 2000 1000 1200 1400 1600 1800 2000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 65.4 59.2 53.0 47.0 68.3 61.8 55.3 49.1 48.9 71.2 64.4 57.7 51.1 51.0 74.1 67.1 60.0 53.2 53.1 69.2 62.0 54.9 54.8 71.4 63.9 56.6 56.5 3.0 3.0 2.9 2.9 3.0 3.0 2.9 2.9 2.9 3.0 3.0 2.9 2.9 2.9 3.0 3.0 2.9 2.9 2.9 3.0 3.0 3.0 2.9 3.1 3.0 3.0 3.0 28.0 34.8 41.6 47.0 30.8 38.0 45.3 49.1 48.9 33.6 41.3 49.0 51.1 51.0 36.4 44.6 52.8 53.2 53.1 48.1 58.3 54.9 54.8 51.6 63.9 56.6 56.5 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 55.3 49.9 44.5 39.3 57.5 51.9 46.4 40.9 40.6 59.8 54.0 48.2 42.5 42.2 62.0 56.0 50.0 44.1 43.8 57.6 51.4 45.3 45.0 59.1 52.7 46.5 46.2 3.6 3.6 3.5 3.4 3.6 3.6 3.5 3.4 3.5 3.7 3.6 3.6 3.5 3.5 3.7 3.6 3.6 3.5 3.5 3.7 3.6 3.5 3.6 3.7 3.7 3.6 3.6 22.2 28.9 35.5 39.3 25.1 32.4 39.8 40.9 40.6 27.9 35.9 44.0 42.5 42.2 30.8 39.5 48.2 44.1 43.8 42.7 50.5 45.3 45.0 46.0 52.7 46.5 46.2 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 23.5 19.1 60.3 3.3 30.3 25.9 21.4 54.5 3.3 37.1 32.7 28.3 23.8 48.8 3.2 47.0 40.3 35.9 31.4 27.0 43.1 3.2 25.6 20.4 62.9 3.3 32.9 27.7 22.5 56.9 3.3 40.1 35.0 29.8 24.6 50.9 3.2 49.1 43.1 38.0 32.8 27.6 45.0 3.2 48.9 47.1 42.0 36.8 31.6 44.8 3.2 27.7 21.8 65.5 3.3 35.4 29.5 23.6 59.2 3.3 43.1 37.3 31.4 25.5 52.9 3.2 51.1 46.0 40.1 34.2 28.3 46.8 3.2 51.0 50.3 44.4 38.5 32.6 46.6 3.2 29.8 23.2 68.1 3.4 38.0 31.4 24.7 61.5 3.3 46.1 39.5 32.9 26.3 55.0 3.3 53.2 48.8 42.1 35.5 28.9 48.7 3.2 53.1 53.4 46.8 40.2 33.5 48.4 3.2 40.9 33.6 26.4 63.4 3.4 49.6 42.4 35.2 28.0 56.7 3.3 54.9 52.7 45.5 38.3 31.1 50.1 3.3 54.8 54.9 47.7 40.5 33.3 49.9 3.2 43.7 35.9 28.1 65.2 3.4 53.1 45.3 37.5 29.7 58.3 3.3 56.6 56.6 48.8 41.0 33.2 51.6 3.3 56.5 56.5 48.6 40.8 33.0 51.4 3.3 95°F 18.0 13.8 50.6 4.0 24.7 20.5 16.3 45.4 3.9 31.3 27.1 22.9 18.7 40.1 3.8 39.3 33.9 29.7 25.5 21.3 36.2 3.7 20.1 15.2 52.4 4.0 27.5 22.6 17.6 47.0 3.9 34.8 29.9 25.0 20.0 41.5 3.8 40.9 37.3 32.4 27.4 22.5 37.5 3.7 40.6 37.4 32.4 27.5 22.6 37.1 3.7 22.3 16.6 54.3 4.0 30.3 24.6 19.0 48.6 3.9 38.3 32.6 27.0 21.3 43.0 3.8 42.5 40.7 35.1 29.4 23.7 38.8 3.8 42.2 40.8 35.1 29.5 23.8 38.4 3.8 24.4 18.0 56.1 4.1 33.1 26.7 20.3 50.2 4.0 41.8 35.4 29.0 22.6 44.4 3.9 44.1 44.1 37.8 31.4 25.0 40.1 3.8 43.8 44.2 37.8 31.5 25.1 39.7 3.8 35.7 28.7 21.7 51.6 4.0 45.1 38.0 31.0 24.0 45.6 3.9 45.3 45.3 38.3 31.3 24.3 41.2 3.8 45.0 45.2 38.2 31.2 24.2 40.8 3.8 38.3 30.7 23.0 53.0 4.1 48.3 40.7 33.0 25.3 46.8 4.0 46.5 46.5 38.9 31.2 23.6 42.2 3.9 46.2 46.2 38.6 30.9 23.2 41.8 3.9 90 25.1 31.8 38.6 43.1 27.9 35.2 42.5 45.0 44.8 30.7 38.6 46.5 46.8 46.6 33.6 42.0 50.5 48.7 48.4 45.4 54.4 50.1 49.9 48.8 58.3 51.6 51.4 19.3 26.7 34.2 36.2 22.9 30.1 37.3 37.5 37.1 26.6 33.5 40.4 38.8 38.4 30.3 36.9 43.5 40.1 39.7 40.1 45.2 41.2 40.8 43.3 46.8 42.2 41.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 20.8 16.4 27.5 23.2 18.9 34.2 29.9 25.6 21.3 43.1 37.1 32.8 28.5 22.9 17.8 30.2 25.1 20.1 37.5 32.4 27.4 22.3 45.0 40.2 35.2 30.1 44.8 42.3 37.2 32.2 25.0 19.2 32.9 27.1 21.3 40.7 35.0 29.2 23.4 46.8 43.3 37.6 31.8 46.6 45.5 39.8 34.0 27.1 20.6 35.5 29.0 22.5 44.0 37.5 31.0 24.5 48.7 46.5 40.0 33.5 48.4 48.8 42.3 35.8 38.3 31.2 24.0 47.4 40.2 33.1 26.0 50.1 49.0 41.9 34.8 49.9 50.1 43.0 35.8 41.0 33.3 25.6 50.7 43.0 35.2 27.5 51.6 51.6 43.9 36.1 51.4 51.4 43.6 35.9 105°F 16.2 12.1 22.7 18.6 14.5 29.1 25.1 21.0 16.9 36.2 30.9 26.9 22.8 18.2 13.4 25.3 20.5 15.7 32.5 27.7 22.9 18.1 37.5 34.2 29.4 24.6 37.1 33.8 29.0 24.2 20.1 14.6 28.0 22.5 17.0 35.8 30.3 24.8 19.3 38.8 37.4 31.9 26.4 38.4 37.0 31.4 25.9 22.1 15.9 30.6 24.4 18.2 39.2 32.9 26.7 20.5 40.1 40.7 34.4 28.2 39.7 40.2 33.9 27.7 33.2 26.3 19.5 41.9 35.5 28.6 21.8 41.2 41.5 34.6 27.7 40.8 41.0 34.1 27.2 35.8 28.3 20.7 44.6 38.1 30.6 23.1 42.2 42.2 34.7 27.2 41.8 41.8 34.3 26.8 65 24.1 25.1 27.1 26.0 28.2 27.0 29.3 27.7 28.7 28.4 28.1 18.7 19.8 19.4 20.9 20.4 22.0 21.5 20.8 20.4 19.6 19.2 37 528150-YTG-T-0514 ZH049 (4.0 Ton) (Continued) Air on Evaporator Coil CFM 1000 1200 1400 1600 1800 2000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 46.0 40.8 35.6 33.1 47.4 42.0 36.7 34.0 33.6 48.7 43.2 37.8 35.0 34.6 50.1 44.4 38.8 36.0 35.5 45.6 39.9 37.0 36.5 46.8 40.9 37.9 37.4 4.3 4.2 4.1 4.0 4.4 4.2 4.1 4.0 4.0 4.4 4.3 4.1 4.1 4.1 4.4 4.3 4.2 4.1 4.1 4.4 4.2 4.1 4.1 4.4 4.3 4.2 4.2 16.4 24.6 32.8 33.1 20.8 27.8 34.8 34.0 33.6 25.3 31.0 36.8 35.0 34.6 29.7 34.3 38.8 36.0 35.5 37.5 39.9 37.0 36.5 40.6 40.9 37.9 37.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 14.3 10.4 41.4 4.7 20.6 16.7 12.7 36.3 4.5 26.9 23.0 19.0 15.1 31.2 4.3 33.1 28.0 24.1 20.1 16.2 29.9 4.3 16.2 11.5 42.3 4.7 23.1 18.5 13.8 37.1 4.5 30.1 25.5 20.8 16.2 31.9 4.4 34.0 31.1 26.4 21.8 17.1 30.6 4.3 33.6 30.2 25.5 20.8 16.2 30.1 4.3 18.0 12.6 43.2 4.8 25.7 20.3 14.9 37.9 4.6 33.3 28.0 22.6 17.2 32.5 4.4 35.0 34.1 28.8 23.4 18.0 31.3 4.3 34.6 33.1 27.8 22.4 17.0 30.7 4.3 19.9 13.8 44.1 4.8 28.2 22.1 16.0 38.7 4.6 36.5 30.5 24.4 18.3 33.2 4.4 36.0 37.2 31.1 25.0 19.0 31.9 4.4 35.5 36.1 30.0 23.9 17.9 31.4 4.4 30.7 24.0 17.2 39.7 4.7 38.7 33.0 26.3 19.6 34.1 4.5 37.0 37.6 30.8 24.1 17.4 32.8 4.4 36.5 36.8 30.0 23.3 16.5 32.2 4.4 33.2 25.8 18.4 40.7 4.8 40.9 35.6 28.2 20.8 35.0 4.6 37.9 37.9 30.5 23.1 15.7 33.6 4.5 37.4 37.4 30.0 22.6 15.2 33.1 4.5 90 13.7 22.4 31.2 29.9 19.1 25.5 31.9 30.6 30.1 24.6 28.6 32.5 31.3 30.7 30.1 31.7 33.2 31.9 31.4 34.8 34.1 32.8 32.2 38.0 35.0 33.6 33.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 12.1 8.7 18.6 14.8 11.0 24.7 20.9 17.1 13.2 29.9 25.1 21.3 17.5 14.2 9.7 21.0 16.5 11.9 27.8 23.3 18.7 14.2 30.6 28.0 23.5 19.0 30.1 26.6 22.0 17.5 16.2 10.7 23.4 18.1 12.9 30.8 25.6 20.4 15.2 31.3 30.9 25.6 20.4 30.7 29.3 24.1 18.8 18.3 11.7 25.7 19.8 13.9 33.2 28.0 22.1 16.2 31.9 31.9 27.8 21.9 31.4 31.4 26.1 20.2 28.2 21.6 15.0 34.1 30.5 23.9 17.3 32.8 32.8 27.1 20.5 32.2 32.2 25.9 19.3 30.7 23.4 16.2 35.0 33.0 25.8 18.5 33.6 33.6 26.4 19.1 33.1 33.1 25.8 18.5 65 13.7 14.4 13.0 15.2 13.6 16.0 14.2 13.9 12.7 11.8 11.2 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 38 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH061 (5.0 Ton) Air on Evaporator Coil CFM 1250 1500 1750 2000 2250 2500 1250 1500 1750 2000 2250 2500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 82.5 74.3 66.2 59.3 84.7 76.3 68.0 60.9 61.6 86.9 78.4 69.8 62.5 63.3 89.2 80.4 71.6 64.1 64.9 83.6 74.5 66.7 67.5 86.9 77.3 69.3 70.0 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 36.6 43.9 51.1 59.3 40.0 48.4 56.7 60.9 61.6 43.5 52.8 62.2 62.5 63.3 47.0 57.3 67.7 64.1 64.9 61.7 72.5 66.7 67.5 66.1 77.3 69.3 70.0 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 69.3 62.3 55.2 49.7 71.7 64.4 57.1 51.4 48.8 74.0 66.5 58.9 53.0 50.4 76.3 68.6 60.8 54.7 52.0 68.8 61.0 54.9 52.2 69.0 61.2 55.0 52.3 4.3 4.3 4.2 4.1 4.3 4.3 4.2 4.2 4.2 4.3 4.3 4.2 4.2 4.2 4.4 4.3 4.2 4.2 4.2 4.3 4.2 4.2 4.2 4.3 4.2 4.2 4.2 29.2 37.9 46.5 49.7 33.3 42.3 51.3 51.4 48.8 37.3 46.7 56.0 53.0 50.4 41.4 51.1 60.8 54.7 52.0 55.2 61.0 54.9 52.2 59.4 61.2 55.0 52.3 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 30.6 25.1 75.9 3.9 38.3 32.8 27.3 68.3 3.8 46.0 40.5 35.0 29.4 60.7 3.8 59.3 49.5 43.9 38.4 32.9 54.5 3.8 33.6 27.1 78.2 3.9 41.9 35.4 29.0 70.4 3.9 50.2 43.8 37.3 30.8 62.5 3.8 60.9 53.4 47.0 40.5 34.1 56.1 3.8 61.6 54.9 48.4 41.9 35.5 55.2 3.8 36.5 29.1 80.5 3.9 45.5 38.1 30.7 72.4 3.9 54.4 47.0 39.6 32.2 64.4 3.8 62.5 57.4 50.0 42.6 35.2 57.8 3.8 63.3 58.9 51.6 44.2 36.8 56.8 3.8 39.5 31.2 82.7 3.9 49.0 40.7 32.4 74.5 3.9 58.6 50.3 41.9 33.6 66.2 3.8 64.1 61.4 53.1 44.7 36.4 59.4 3.8 64.9 63.0 54.7 46.4 38.1 58.5 3.8 52.7 43.6 34.5 76.2 3.9 62.9 53.8 44.7 35.7 67.7 3.8 66.7 65.3 56.3 47.2 38.1 60.8 3.8 67.5 66.5 57.5 48.4 39.3 59.8 3.8 56.3 46.5 36.6 77.9 3.9 67.3 57.3 47.5 37.7 69.3 3.8 69.3 69.3 59.5 49.6 39.8 62.2 3.8 70.0 70.0 60.2 50.4 40.5 61.2 3.8 95°F 24.1 18.6 62.5 4.7 32.4 26.9 21.4 55.9 4.6 40.6 35.1 29.6 24.1 49.4 4.6 49.7 43.0 37.5 32.0 26.5 44.7 4.5 26.8 20.4 64.8 4.8 35.8 29.4 23.0 58.0 4.7 44.8 38.4 32.0 25.6 51.1 4.6 51.4 47.1 40.6 34.2 27.8 46.3 4.5 48.8 46.3 39.8 33.4 27.0 44.1 4.5 29.5 22.2 67.1 4.8 39.3 31.9 24.6 60.0 4.7 49.1 41.7 34.4 27.0 52.9 4.6 53.0 51.1 43.8 36.4 29.0 47.9 4.5 50.4 50.2 42.9 35.5 28.2 45.7 4.5 32.2 23.9 69.3 4.8 42.8 34.5 26.2 62.0 4.7 53.3 45.0 36.8 28.5 54.7 4.6 54.7 55.2 46.9 38.6 30.3 49.6 4.5 52.0 54.2 45.9 37.7 29.4 47.2 4.5 46.0 36.9 27.7 62.0 4.7 57.3 48.2 39.0 29.8 54.7 4.6 54.9 55.1 45.9 36.7 27.6 49.5 4.5 52.2 53.3 44.1 34.9 25.7 47.2 4.6 49.3 39.2 29.2 62.0 4.7 61.2 51.3 41.2 31.1 54.7 4.6 55.0 55.0 45.0 34.9 24.8 49.5 4.5 52.3 52.3 42.3 32.2 22.1 47.2 4.6 90 32.9 40.9 48.8 54.5 36.6 45.3 54.0 56.1 55.2 40.4 49.8 59.1 57.8 56.8 44.2 54.2 64.3 59.4 58.5 58.5 66.8 60.8 59.8 62.7 69.3 62.2 61.2 25.5 35.3 45.0 44.7 31.0 39.6 48.2 46.3 44.1 36.5 44.0 51.5 47.9 45.7 42.0 48.4 54.7 49.6 47.2 52.4 54.7 49.5 47.2 56.4 54.7 49.5 47.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 27.4 21.9 35.3 29.8 24.3 43.3 37.8 32.3 26.8 54.5 46.2 40.7 35.2 30.2 23.8 38.9 32.4 26.0 47.5 41.1 34.6 28.2 56.1 50.2 43.8 37.4 55.2 50.6 44.1 37.7 33.0 25.7 42.4 35.0 27.6 51.7 44.4 37.0 29.6 57.8 54.3 46.9 39.5 56.8 54.6 47.2 39.8 35.9 27.6 45.9 37.6 29.3 56.0 47.7 39.3 31.0 59.4 58.3 50.0 41.7 58.5 58.6 50.3 42.0 49.3 40.2 31.1 60.1 51.0 41.9 32.7 60.8 60.2 51.1 42.0 59.8 59.9 50.8 41.7 52.8 42.8 32.9 64.2 54.3 44.4 34.4 62.2 62.2 52.2 42.3 61.2 61.2 51.2 41.3 105°F 21.7 16.3 29.9 24.5 19.0 38.1 32.6 27.2 21.8 44.7 40.1 34.7 29.3 24.3 17.9 33.3 26.9 20.5 42.3 35.9 29.5 23.2 46.3 44.2 37.8 31.4 44.1 42.1 35.7 29.4 26.8 19.5 36.7 29.3 22.0 46.5 39.2 31.8 24.5 47.9 48.3 40.9 33.6 45.7 45.9 38.6 31.3 29.4 21.1 40.1 31.8 23.5 50.7 42.4 34.1 25.9 49.6 52.4 44.1 35.8 47.2 49.7 41.4 33.2 43.2 34.0 24.9 52.7 45.5 36.3 27.1 49.5 50.9 41.8 32.6 47.2 48.5 39.3 30.1 46.4 36.3 26.3 54.7 48.5 38.5 28.4 49.5 49.5 39.5 29.4 47.2 47.2 37.1 27.1 65 29.7 30.9 31.2 32.1 32.5 33.4 33.7 32.8 32.5 32.3 31.3 23.8 25.1 23.0 26.3 23.9 27.5 24.9 23.4 21.0 19.4 17.0 39 528150-YTG-T-0514 ZH061 (5.0 Ton) (Continued) Air on Evaporator Coil CFM 1250 1500 1750 2000 2250 2500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 55.7 49.6 43.5 39.7 57.9 51.6 45.2 41.3 39.4 60.1 53.5 46.9 42.8 40.9 62.3 55.5 48.6 44.4 42.4 55.2 48.4 44.2 42.2 54.9 48.2 44.0 42.0 5.2 5.0 4.9 4.8 5.2 5.1 4.9 4.8 4.9 5.2 5.1 5.0 4.9 4.9 5.3 5.1 5.0 4.9 4.9 5.1 5.0 4.9 4.9 5.2 5.0 4.9 5.0 21.9 32.7 43.5 39.7 28.8 37.0 45.2 41.3 39.4 35.7 41.3 46.9 42.8 40.9 42.7 45.6 48.6 44.4 42.4 49.5 48.4 44.2 42.2 53.5 48.2 44.0 42.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 19.2 13.9 48.9 5.6 27.4 22.0 16.7 43.3 5.4 35.5 30.2 24.9 19.5 37.6 5.3 39.7 37.2 31.8 26.5 21.2 34.7 5.1 21.7 15.4 51.1 5.6 30.7 24.4 18.1 45.2 5.5 39.7 33.4 27.1 20.8 39.2 5.3 41.3 41.3 35.0 28.7 22.3 36.2 5.2 39.4 37.9 31.6 25.3 19.0 34.7 5.2 24.1 16.8 53.2 5.7 34.0 26.7 19.4 47.1 5.5 43.9 36.6 29.3 22.0 40.9 5.3 42.8 45.4 38.1 30.8 23.5 37.8 5.2 40.9 41.6 34.3 27.0 19.7 36.2 5.3 26.6 18.3 55.4 5.7 37.4 29.1 20.8 49.0 5.5 48.1 39.8 31.5 23.3 42.5 5.4 44.4 49.5 41.2 33.0 24.7 39.3 5.2 42.4 45.2 36.9 28.7 20.4 37.6 5.3 40.4 31.2 22.1 48.4 5.6 48.1 42.8 33.6 24.5 42.1 5.4 44.2 46.7 37.6 28.4 19.3 38.9 5.3 42.2 43.6 34.5 25.3 16.2 37.2 5.3 43.4 33.4 23.4 47.9 5.6 48.2 45.7 35.7 25.7 41.6 5.4 44.0 44.0 34.0 23.9 13.9 38.5 5.3 42.0 42.0 32.0 22.0 11.9 36.9 5.4 90 22.6 30.1 37.6 34.7 29.5 34.4 39.2 36.2 34.7 36.4 38.6 40.9 37.8 36.2 43.3 42.9 42.5 39.3 37.6 46.7 42.1 38.9 37.2 47.9 41.6 38.5 36.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 15.3 11.5 24.9 19.6 14.4 33.4 27.7 22.5 17.3 34.7 34.7 29.0 23.8 19.1 12.9 28.1 21.9 15.6 37.1 30.9 24.6 18.4 36.2 36.2 32.1 25.9 34.7 33.8 27.5 21.3 22.9 14.2 31.4 24.1 16.9 40.9 34.1 26.8 19.5 37.8 37.8 35.3 28.0 36.2 36.2 30.0 22.7 26.7 15.5 34.6 26.4 18.1 42.5 37.2 28.9 20.7 39.3 39.3 38.4 30.1 37.6 37.6 32.4 24.2 37.6 28.4 19.3 42.1 40.1 31.0 21.8 38.9 38.9 33.4 24.3 37.2 37.2 29.6 20.5 40.5 30.5 20.5 41.6 41.6 33.0 23.0 38.5 38.5 28.4 18.4 36.9 36.9 26.8 16.8 65 18.5 19.6 15.0 20.7 15.5 21.9 15.9 15.1 11.4 8.4 6.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 40 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078 (6.5 Ton) Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 1625 1950 2275 2600 2925 3250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 100.1 92.7 85.4 74.8 105.7 97.9 90.1 79.0 77.8 111.4 103.1 94.8 83.3 82.0 117.0 108.3 99.5 87.5 86.2 110.3 101.4 89.1 87.7 112.3 103.3 90.7 89.3 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.8 4.7 4.7 4.7 4.7 4.8 4.7 4.7 4.7 4.8 4.7 4.7 4.7 4.7 4.7 4.7 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 96.1 86.0 75.9 70.3 98.3 88.0 77.7 71.9 72.8 100.5 89.9 79.4 73.5 74.5 102.6 91.9 81.1 75.1 76.1 95.2 84.0 77.8 78.8 98.5 87.0 80.5 81.6 5.9 5.8 5.8 5.8 6.0 5.9 5.8 5.8 5.7 6.0 5.9 5.8 5.8 5.7 6.0 5.9 5.8 5.8 5.8 5.9 5.8 5.8 5.8 5.9 5.9 5.9 5.8 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 90 85 80 75 70 65 75°F 38.5 33.6 28.8 98.1 5.3 49.4 44.5 39.7 34.9 89.4 5.3 60.2 55.4 50.6 45.7 40.9 80.6 5.2 74.8 69.6 61.2 56.4 51.6 46.7 72.6 5.2 47.6 39.7 31.8 102.0 5.3 59.7 51.8 43.9 35.9 92.9 5.3 71.7 63.8 55.9 48.0 40.1 83.9 5.3 79.0 75.6 67.6 59.7 51.8 43.9 75.5 5.2 77.8 79.4 72.1 64.2 56.3 48.4 75.3 5.2 56.8 45.8 34.8 105.9 5.3 70.0 59.0 48.0 37.0 96.5 5.3 83.2 72.2 61.2 50.2 39.2 87.1 5.3 83.3 81.5 74.1 63.1 52.1 41.1 78.4 5.2 82.0 82.8 78.9 67.9 56.9 46.0 78.2 5.2 66.0 51.9 37.8 109.8 5.3 80.3 66.2 52.2 38.1 100.1 5.3 94.6 80.5 66.5 52.4 38.4 90.3 5.3 87.5 87.5 80.5 66.4 52.4 38.3 81.3 5.2 86.2 86.2 85.7 71.7 57.6 43.6 81.1 5.2 82.3 69.0 55.6 42.3 102.7 5.3 99.0 84.2 70.9 57.6 44.2 92.7 5.3 89.1 89.1 85.6 72.3 58.9 45.6 83.4 5.3 87.7 87.7 87.5 74.2 60.9 47.5 83.3 5.2 84.4 71.7 59.1 46.5 105.4 5.3 103.3 88.0 75.3 62.7 50.1 95.1 5.3 90.7 90.7 90.7 78.1 65.5 52.8 85.6 5.3 89.3 89.3 89.3 76.7 64.1 51.4 85.4 5.3 95°F 41.0 32.2 23.5 87.2 6.5 52.3 43.5 34.8 26.0 78.4 6.3 63.6 54.8 46.1 37.3 28.6 69.5 6.2 70.3 67.6 56.5 47.7 39.0 30.2 63.1 6.1 41.8 33.8 25.8 89.3 6.5 54.3 46.2 38.2 30.2 80.2 6.4 66.7 58.7 50.6 42.6 34.6 71.2 6.3 71.9 70.1 62.1 54.1 46.0 38.0 64.6 6.2 72.8 71.3 63.3 55.3 47.2 39.2 67.1 6.2 42.7 35.4 28.1 91.3 6.5 56.3 49.0 41.7 34.4 82.1 6.4 69.8 62.5 55.2 47.9 40.6 72.8 6.3 73.5 72.6 67.7 60.4 53.1 45.8 66.1 6.2 74.5 73.7 69.0 61.7 54.4 47.1 68.7 6.2 43.6 37.0 30.4 93.4 6.5 58.2 51.7 45.1 38.5 83.9 6.4 72.9 66.3 59.8 53.2 46.6 74.5 6.3 75.1 75.1 73.3 66.7 60.2 53.6 67.5 6.2 76.1 76.1 74.7 68.1 61.6 55.0 70.2 6.2 66.8 57.4 48.0 38.7 86.3 6.5 79.9 73.0 63.7 54.3 45.0 76.6 6.3 77.8 77.8 76.9 67.5 58.2 48.8 69.4 6.2 78.8 78.8 78.1 68.8 59.4 50.1 72.2 6.3 75.3 63.1 51.0 38.8 88.6 6.5 87.0 79.7 67.6 55.4 43.3 78.6 6.4 80.5 80.5 80.5 68.4 56.2 44.1 71.3 6.3 81.6 81.6 81.6 69.4 57.3 45.1 74.1 6.3 90 39.7 50.8 61.9 72.6 44.7 57.0 69.2 75.5 75.3 49.8 63.1 76.5 78.4 78.2 54.8 69.3 83.8 81.3 81.1 74.5 89.4 83.4 83.3 79.8 95.1 85.6 85.4 36.1 48.5 60.8 63.1 39.9 51.9 64.0 64.6 67.1 43.6 55.4 67.2 66.1 68.7 47.4 58.9 70.4 67.5 70.2 65.6 74.5 69.4 72.2 72.3 78.6 71.3 74.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 32.9 26.1 44.0 37.2 30.4 55.1 48.3 41.5 34.7 68.6 58.8 52.1 45.3 36.8 28.8 49.0 41.0 33.1 61.2 53.3 45.3 37.3 72.8 64.9 56.9 48.9 75.3 67.7 59.7 51.7 40.6 31.5 54.0 44.8 35.7 67.3 58.2 49.1 39.9 77.1 70.9 61.7 52.6 78.2 74.0 64.8 55.7 44.5 34.1 58.9 48.6 38.3 73.4 63.1 52.8 42.5 81.3 76.9 66.6 56.3 81.1 80.2 69.9 59.6 63.2 51.8 40.5 78.6 67.3 55.9 44.6 83.4 81.2 69.9 58.5 83.3 82.8 71.5 60.1 67.4 55.0 42.7 83.8 71.4 59.1 46.7 85.6 85.6 73.2 60.8 85.4 85.4 73.1 60.7 105°F 29.5 21.5 40.4 32.4 24.4 51.4 43.4 35.4 27.4 61.7 53.8 45.8 37.8 31.7 23.6 43.8 35.7 27.6 55.9 47.8 39.7 31.5 63.7 59.2 51.1 43.0 66.3 58.2 50.1 41.9 34.0 25.8 47.2 38.9 30.7 60.4 52.1 43.9 35.7 65.6 64.6 56.4 48.1 68.3 63.5 55.3 47.0 36.3 27.9 50.6 42.2 33.8 64.8 56.5 48.1 39.8 67.5 70.0 61.6 53.3 70.2 68.8 60.5 52.1 55.3 45.1 34.8 69.9 60.4 50.1 39.9 69.4 70.7 60.4 50.2 72.2 71.5 61.2 51.0 60.1 48.0 35.8 75.0 64.2 52.1 40.0 71.3 71.3 59.2 47.1 74.1 74.1 62.0 49.9 65 38.5 41.0 43.8 43.5 46.5 45.9 49.3 47.2 48.8 48.4 48.3 29.8 34.8 33.8 39.9 38.8 44.9 43.7 39.9 40.7 34.9 37.7 41 528150-YTG-T-0514 ZH078 (6.5 Ton) (Continued) Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 78.3 70.7 63.2 55.8 80.3 72.5 64.7 57.2 61.4 82.2 74.2 66.3 58.6 62.9 84.1 76.0 67.9 60.0 64.4 77.4 69.1 61.1 65.6 78.8 70.3 62.2 66.7 7.0 6.8 6.7 6.5 7.0 6.9 6.7 6.6 6.6 7.1 6.9 6.8 6.6 6.7 7.1 7.0 6.8 6.6 6.7 7.0 6.8 6.7 6.7 7.0 6.9 6.7 6.8 31.2 44.7 58.1 55.8 37.9 49.6 61.4 57.2 61.4 44.6 54.6 64.6 58.6 62.9 51.3 59.6 67.9 60.0 64.4 64.4 69.1 61.1 65.6 69.2 70.3 62.2 66.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 26.7 19.5 69.4 7.5 37.4 30.1 22.9 63.1 7.3 48.0 40.8 33.5 26.2 56.8 7.1 55.8 51.1 43.9 36.6 29.3 48.6 6.9 29.7 21.4 71.3 7.6 41.4 33.2 24.9 64.8 7.4 53.1 44.9 36.7 28.5 58.3 7.2 57.2 56.3 48.1 39.9 31.6 49.9 6.9 61.3 53.1 44.9 36.7 28.4 55.7 7.1 32.6 23.4 73.1 7.6 45.4 36.2 27.0 66.4 7.4 58.2 49.1 39.9 30.7 59.7 7.3 58.6 61.5 52.3 43.1 34.0 51.2 7.0 62.9 58.0 48.8 39.6 30.5 57.1 7.1 35.5 25.4 74.9 7.7 49.4 39.3 29.1 68.1 7.5 63.3 53.2 43.1 32.9 61.2 7.3 60.0 66.7 56.6 46.4 36.3 52.4 7.1 64.4 62.9 52.8 42.6 32.5 58.5 7.2 53.3 42.1 31.0 68.5 7.5 66.8 57.0 45.9 34.8 61.6 7.3 61.1 64.4 53.3 42.2 31.0 52.7 7.1 65.6 64.8 53.7 42.5 31.4 58.9 7.2 57.1 45.0 32.9 68.9 7.6 70.3 60.9 48.8 36.6 62.0 7.4 62.2 62.2 50.0 37.9 25.8 53.0 7.1 66.7 66.7 54.6 42.5 30.3 59.3 7.2 90 24.9 40.9 56.8 48.6 36.4 47.3 58.3 49.9 55.7 47.8 53.8 59.7 51.2 57.1 59.3 60.2 61.2 52.4 58.5 63.2 61.6 52.7 58.9 66.2 62.0 53.0 59.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 23.7 17.5 34.3 27.8 21.3 44.7 38.1 31.6 25.1 48.6 48.6 41.9 35.4 27.6 19.3 39.0 30.7 22.3 50.4 42.1 33.7 25.4 49.9 49.9 45.1 36.8 55.7 48.0 39.7 31.4 31.5 21.1 43.6 33.5 23.4 56.1 46.0 35.9 25.7 51.2 51.2 48.3 38.2 57.1 52.5 42.4 32.3 35.4 22.9 48.3 36.4 24.5 61.2 49.9 38.0 26.0 52.4 52.4 51.5 39.6 58.5 57.0 45.1 33.1 51.2 39.2 27.2 61.6 53.7 41.7 29.7 52.7 52.7 46.2 34.2 58.9 58.2 46.1 34.1 54.1 42.0 29.9 62.0 57.6 45.5 33.3 53.0 53.0 40.9 28.8 59.3 59.3 47.2 35.1 65 28.9 28.5 23.1 28.0 22.1 27.6 21.2 22.1 22.1 16.7 23.0 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 42 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH090 (7.5 Ton) Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 1875 2250 2625 3000 3375 3750 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 113.8 106.0 98.1 86.5 121.4 112.9 104.5 92.2 90.4 128.9 119.9 110.9 97.9 96.1 136.5 126.9 117.3 103.6 101.8 128.9 119.1 105.2 103.4 130.9 121.0 106.8 104.9 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.9 5.9 5.8 5.8 5.8 5.9 5.9 5.9 5.8 5.8 5.9 5.8 5.8 5.8 5.8 5.8 49.0 62.6 76.2 86.5 54.8 69.7 84.6 92.2 90.4 60.6 76.8 93.0 97.9 96.1 66.4 83.9 101.4 103.6 101.8 88.3 110.1 105.2 103.4 92.7 118.7 106.8 104.9 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 110.3 99.9 89.5 81.3 112.2 101.6 91.0 82.7 84.9 114.1 103.3 92.5 84.1 86.3 115.9 105.0 94.0 85.5 87.8 108.3 97.0 88.2 90.5 111.6 100.0 90.9 93.3 7.1 7.0 7.0 6.9 7.1 7.1 7.0 6.9 6.9 7.2 7.1 7.0 6.9 6.9 7.2 7.1 7.1 7.0 7.0 7.1 7.1 7.0 7.0 7.2 7.1 7.0 7.0 44.2 57.2 70.2 81.3 49.0 63.2 77.4 82.7 84.9 53.8 69.2 84.6 84.1 86.3 58.6 75.2 91.7 85.5 87.8 81.4 95.9 88.2 90.5 87.7 100.0 90.9 93.3 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 41.0 33.1 112.1 6.5 54.6 46.7 38.7 102.9 6.4 68.3 60.3 52.3 44.4 93.8 6.4 80.4 71.9 64.0 56.0 48.1 83.9 6.4 45.5 36.3 116.8 6.5 60.4 51.2 41.9 107.3 6.4 75.3 66.1 56.8 47.5 97.7 6.4 88.1 78.8 69.6 60.3 51.0 87.5 6.4 91.7 85.4 76.2 66.9 57.6 87.7 6.4 50.0 39.4 121.5 6.5 66.2 55.6 45.0 111.6 6.5 82.4 71.9 61.3 50.7 101.7 6.4 95.8 85.7 75.1 64.5 54.0 91.0 6.4 96.8 92.9 82.3 71.7 61.1 91.2 6.4 54.5 42.6 126.2 6.5 72.0 60.1 48.2 115.9 6.5 89.5 77.6 65.7 53.8 105.6 6.5 103.6 92.6 80.7 68.8 56.9 94.5 6.4 101.8 100.4 88.5 76.6 64.6 94.8 6.4 75.7 63.2 50.6 118.6 6.5 94.1 81.6 69.0 56.4 108.1 6.5 105.2 99.6 87.0 74.4 61.8 96.7 6.4 103.4 102.6 90.1 77.5 64.9 96.9 6.4 79.5 66.2 53.0 121.2 6.5 98.7 85.5 72.2 59.0 110.5 6.5 106.8 106.5 93.2 80.0 66.7 98.9 6.4 104.9 104.9 91.7 78.4 65.2 99.1 6.4 95°F 36.2 28.1 103.5 7.7 49.2 41.1 33.0 93.1 7.6 62.2 54.1 46.0 37.9 82.7 7.5 77.5 65.0 57.0 48.9 40.8 78.3 7.4 39.8 30.7 103.5 7.8 54.0 44.9 35.7 93.1 7.7 68.2 59.1 49.9 40.7 82.7 7.5 80.2 71.0 61.8 52.7 43.5 78.2 7.4 83.7 74.5 65.3 56.1 47.0 80.0 7.4 43.5 33.2 103.5 7.8 58.9 48.6 38.4 93.1 7.7 74.3 64.0 53.8 43.5 82.7 7.6 82.8 77.0 66.7 56.4 46.2 78.2 7.5 85.7 80.8 70.5 60.2 49.9 79.9 7.5 47.2 35.8 103.4 7.9 63.8 52.4 41.0 93.1 7.7 80.4 69.0 57.6 46.3 82.7 7.6 85.5 83.0 71.6 60.2 48.8 78.1 7.5 87.8 87.0 75.7 64.3 52.9 79.9 7.5 68.9 56.4 43.8 97.2 7.8 86.7 74.2 61.7 49.1 86.4 7.6 88.2 86.9 74.4 61.9 49.3 81.6 7.5 90.5 90.2 77.7 65.1 52.6 83.5 7.5 74.0 60.3 46.6 101.3 7.8 93.1 79.4 65.7 52.0 90.0 7.7 90.9 90.9 77.2 63.5 49.9 85.1 7.5 93.3 93.3 79.7 66.0 52.3 87.0 7.5 90 46.6 59.9 73.2 83.9 51.9 66.5 81.0 87.5 87.7 57.2 73.0 88.8 91.0 91.2 62.5 79.5 96.6 94.5 94.8 84.9 103.0 96.7 96.9 90.2 109.4 98.9 99.1 38.5 54.2 69.8 78.3 45.5 59.6 73.7 78.2 80.0 52.4 65.0 77.6 78.2 79.9 59.4 70.5 81.6 78.1 79.9 76.7 85.8 81.6 83.5 82.8 90.0 85.1 87.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 38.6 30.6 51.9 43.9 35.9 65.2 57.2 49.2 41.2 79.0 68.5 60.5 52.5 42.7 33.5 57.2 48.0 38.8 71.8 62.6 53.3 44.1 84.1 74.9 65.7 56.5 87.7 80.0 70.7 61.5 46.8 36.3 62.6 52.1 41.7 78.4 67.9 57.5 47.1 89.3 81.4 70.9 60.5 91.2 86.8 76.4 66.0 50.8 39.2 67.9 56.3 44.6 85.0 73.3 61.7 50.0 94.5 87.8 76.1 64.5 94.8 93.7 82.1 70.4 72.3 59.8 47.2 90.4 77.9 65.3 52.8 96.7 93.2 80.7 68.1 96.9 96.4 83.9 71.3 76.7 63.3 49.8 95.9 82.4 69.0 55.5 98.9 98.7 85.2 71.8 99.1 99.1 85.7 72.2 105°F 33.2 25.2 46.2 38.2 30.3 59.2 51.2 43.3 35.3 75.8 62.2 54.2 46.2 36.5 27.4 50.6 41.5 32.5 64.7 55.7 46.6 37.6 76.6 67.5 58.5 49.5 78.7 69.7 60.7 51.6 39.7 29.6 54.9 44.8 34.7 70.2 60.1 50.0 39.9 77.4 72.9 62.8 52.7 79.3 75.2 65.1 55.0 43.0 31.8 59.3 48.1 37.0 75.7 64.5 53.3 42.1 78.1 78.2 67.1 55.9 79.9 80.8 69.6 58.4 64.4 52.1 39.8 81.1 69.8 57.5 45.2 81.6 81.7 69.4 57.1 83.5 83.9 71.6 59.3 69.4 56.0 42.6 86.6 75.0 61.6 48.2 85.1 85.1 71.7 58.3 87.0 87.0 73.6 60.2 65 44.4 47.3 52.3 50.1 55.5 52.9 58.8 55.6 58.8 58.3 58.7 38.3 40.4 42.6 42.6 44.9 44.7 47.2 44.8 47.0 44.9 46.8 43 528150-YTG-T-0514 ZH090 (7.5 Ton) (Continued) Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 96.7 86.3 75.9 75.3 94.8 84.6 74.4 73.8 75.0 92.9 82.9 72.9 72.3 73.5 91.0 81.2 71.4 70.8 72.0 86.1 75.7 75.1 76.4 91.0 80.1 79.4 80.7 8.4 8.2 8.0 7.9 8.4 8.2 8.1 7.9 7.9 8.5 8.3 8.1 8.0 8.0 8.5 8.3 8.2 8.0 8.0 8.4 8.2 8.1 8.1 8.4 8.2 8.1 8.1 32.9 51.1 69.4 75.3 42.0 56.0 70.0 73.8 75.0 51.1 60.9 70.7 72.3 73.5 60.2 65.8 71.4 70.8 72.0 71.9 75.7 75.1 76.4 78.0 80.1 79.4 80.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 30.3 22.4 89.9 9.0 43.3 35.4 27.5 79.5 8.8 56.2 48.4 40.5 32.6 69.1 8.5 74.0 59.3 51.5 43.6 35.7 72.2 8.4 33.1 24.2 86.1 9.1 47.1 38.2 29.3 76.1 8.8 61.1 52.2 43.3 34.4 66.1 8.6 73.0 64.1 55.2 46.3 37.4 69.3 8.4 73.8 64.9 56.0 47.1 38.2 70.1 8.5 35.9 26.0 82.3 9.1 51.0 41.0 31.1 72.7 8.9 66.0 56.1 46.2 36.2 63.1 8.6 71.9 68.8 58.9 48.9 39.0 66.4 8.5 72.9 69.7 59.8 49.8 39.9 67.1 8.5 38.7 27.8 78.5 9.2 54.8 43.9 32.9 69.3 8.9 70.9 60.0 49.0 38.0 60.1 8.7 70.8 73.5 62.6 51.6 40.6 63.5 8.5 72.0 74.5 63.5 52.5 41.6 64.1 8.6 59.9 47.8 35.7 75.0 9.0 75.5 65.3 53.3 41.2 65.1 8.7 75.1 76.5 64.4 52.3 40.3 68.6 8.6 76.4 77.6 65.5 53.5 41.4 69.3 8.6 64.9 51.7 38.5 80.7 9.0 80.1 70.7 57.5 44.4 70.1 8.8 79.4 79.4 66.2 53.1 39.9 73.6 8.6 80.7 80.7 67.6 54.4 41.2 74.4 8.6 90 27.0 48.1 69.1 72.2 38.7 52.4 66.1 69.3 70.1 50.5 56.8 63.1 66.4 67.1 62.2 61.2 60.1 63.5 64.1 67.2 65.1 68.6 69.3 73.2 70.1 73.6 74.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 24.2 19.6 40.3 32.5 24.8 53.3 45.5 37.8 30.0 72.2 56.5 48.7 40.9 29.7 20.9 43.7 34.9 26.1 57.6 48.8 40.1 31.3 69.3 60.6 51.8 43.1 68.9 60.1 51.3 42.6 35.2 22.3 47.0 37.2 27.5 61.9 52.1 42.4 32.6 66.4 64.7 54.9 45.2 66.5 64.2 54.4 44.6 40.6 23.7 50.4 39.6 28.8 60.1 55.5 44.7 33.9 63.5 63.5 58.1 47.3 64.1 64.1 57.5 46.7 55.3 43.5 31.7 65.1 60.9 49.1 37.2 68.6 68.6 59.4 47.5 69.3 69.3 59.5 47.6 60.3 47.4 34.5 70.1 66.3 53.4 40.5 73.6 73.6 60.7 47.8 74.4 74.4 61.5 48.6 65 33.2 34.3 33.8 35.4 34.8 36.5 35.9 35.7 35.8 34.9 35.7 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 44 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH102 (8.5 Ton) Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 2125 2550 2975 3400 3825 4250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 136.4 127.5 118.6 103.1 142.1 132.8 123.4 107.3 103.7 147.8 138.0 128.1 111.6 107.8 153.6 143.2 132.9 115.8 111.9 145.4 135.0 117.5 113.5 147.6 137.0 119.3 115.2 6.4 6.3 6.3 6.3 6.4 6.3 6.3 6.4 6.3 6.4 6.4 6.3 6.4 6.3 6.4 6.4 6.3 6.4 6.3 6.4 6.3 6.4 6.3 6.4 6.3 6.4 6.3 58.7 74.7 90.7 103.1 65.3 82.7 100.2 107.3 103.7 71.8 90.7 109.6 111.6 107.8 78.4 98.7 119.0 115.8 111.9 105.1 128.0 117.5 113.5 111.5 137.0 119.3 115.2 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 133.1 118.2 103.3 95.6 134.7 119.6 104.5 96.7 93.6 136.3 121.0 105.8 97.8 94.7 137.9 122.4 107.0 99.0 95.8 125.8 109.9 101.7 98.4 129.2 112.9 104.4 101.0 7.7 7.6 7.6 7.4 7.7 7.7 7.6 7.5 7.5 7.8 7.7 7.7 7.5 7.6 7.8 7.8 7.7 7.6 7.6 7.8 7.7 7.6 7.6 7.8 7.8 7.6 7.7 56.1 69.6 83.1 95.6 61.8 76.3 90.8 96.7 93.6 67.5 83.0 98.5 97.8 94.7 73.2 89.7 106.2 99.0 95.8 96.9 109.5 101.7 98.4 104.1 112.9 104.4 101.0 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 49.1 39.5 134.8 7.0 65.1 55.5 45.9 122.9 7.0 81.1 71.5 61.9 52.3 111.0 6.9 94.8 83.2 73.6 64.0 54.4 99.3 6.9 54.2 43.1 138.4 7.1 71.6 60.6 49.5 126.2 7.0 89.1 78.0 66.9 55.8 114.0 6.9 101.8 90.7 79.6 68.6 57.5 102.0 6.9 103.7 95.2 84.1 73.1 62.0 98.6 6.9 59.3 46.7 142.1 7.1 78.1 65.6 53.0 129.5 7.0 97.0 84.5 71.9 59.4 117.0 7.0 108.8 98.3 85.7 73.2 60.6 104.7 7.0 107.8 103.1 90.6 78.0 65.5 101.2 6.9 64.3 50.3 145.7 7.1 84.7 70.6 56.6 132.8 7.1 105.0 91.0 76.9 62.9 120.0 7.0 115.8 105.8 91.8 77.7 63.7 107.4 7.0 111.9 111.0 97.0 83.0 68.9 103.8 7.0 89.8 74.5 59.1 135.6 7.1 111.2 95.9 80.6 65.3 122.5 7.0 117.5 112.6 97.2 81.9 66.6 109.6 7.0 113.5 113.1 97.8 82.5 67.2 106.0 7.0 94.9 78.3 61.7 138.4 7.1 117.5 100.9 84.2 67.6 124.9 7.0 119.3 119.3 102.7 86.1 69.5 111.8 7.0 115.2 115.2 98.6 82.0 65.4 108.1 7.0 95°F 46.7 37.3 116.2 8.5 60.2 50.8 41.4 104.5 8.3 73.7 64.3 54.9 45.5 92.7 8.2 91.1 77.1 67.7 58.3 48.9 84.7 8.0 50.9 40.0 118.6 8.5 65.4 54.5 43.6 106.6 8.4 79.9 69.0 58.1 47.2 94.6 8.2 93.7 82.8 71.9 61.0 50.1 86.5 8.1 93.6 84.4 73.5 62.6 51.7 84.8 8.1 55.1 42.7 121.0 8.6 70.6 58.2 45.8 108.8 8.4 86.1 73.7 61.3 48.9 96.5 8.3 96.3 88.5 76.1 63.7 51.3 88.3 8.1 94.7 90.2 77.8 65.4 53.0 86.5 8.2 59.4 45.5 123.4 8.6 75.8 62.0 48.1 110.9 8.5 92.3 78.4 64.5 50.7 98.5 8.3 99.0 94.1 80.2 66.4 52.5 90.0 8.2 95.8 95.9 82.1 68.2 54.3 88.3 8.2 81.7 66.6 51.4 112.9 8.5 99.4 84.2 69.1 53.9 100.2 8.4 101.7 99.3 84.1 68.9 53.7 91.6 8.2 98.4 98.5 83.3 68.1 52.9 89.8 8.3 87.6 71.2 54.7 114.8 8.6 106.6 90.1 73.6 57.1 101.9 8.4 104.4 104.4 87.9 71.4 54.9 93.1 8.3 101.0 101.0 84.5 68.0 51.5 91.3 8.3 90 57.4 72.2 86.9 99.3 63.5 79.5 95.5 102.0 98.6 69.7 86.9 104.0 104.7 101.2 75.8 94.2 112.6 107.4 103.8 101.0 118.8 109.6 106.0 107.8 124.9 111.8 108.1 48.4 63.9 79.5 84.7 56.1 70.9 85.7 86.5 84.8 63.9 77.9 91.9 88.3 86.5 71.6 84.8 98.1 90.0 88.3 91.2 100.0 91.6 89.8 97.6 101.9 93.1 91.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 47.9 38.4 62.7 53.1 43.6 77.4 67.9 58.4 48.9 92.9 80.2 70.6 61.1 52.6 41.6 68.5 57.5 46.5 84.5 73.5 62.5 51.5 97.8 86.8 75.8 64.8 98.6 89.8 78.8 67.8 57.2 44.7 74.4 61.9 49.4 91.6 79.1 66.6 54.1 102.6 93.4 80.9 68.4 101.2 96.7 84.2 71.7 61.8 47.9 80.2 66.3 52.3 98.6 84.7 70.7 56.8 107.4 100.0 86.0 72.0 103.8 103.5 89.5 75.6 85.8 70.5 55.2 105.3 90.1 74.8 59.6 109.6 105.9 90.7 75.4 106.0 105.8 90.6 75.3 91.3 74.7 58.2 112.0 95.5 78.9 62.4 111.8 111.8 95.3 78.7 108.1 108.1 91.6 75.0 105°F 41.1 31.9 54.7 45.5 36.2 68.3 59.0 49.8 40.5 82.5 69.4 60.1 50.9 45.3 34.6 60.1 49.3 38.5 74.9 64.1 53.3 42.5 85.0 75.3 64.5 53.7 84.8 76.0 65.2 54.4 49.6 37.3 65.5 53.2 40.9 81.5 69.2 56.8 44.5 87.5 81.2 68.9 56.5 86.5 82.0 69.6 57.3 53.8 39.9 71.0 57.1 43.2 88.1 74.2 60.3 46.5 90.0 87.1 73.2 59.4 88.3 87.9 74.1 60.2 76.2 61.1 46.1 93.4 79.5 64.4 49.4 91.6 90.1 75.1 60.0 89.8 89.6 74.6 59.5 81.4 65.2 49.0 98.7 84.7 68.5 52.3 93.1 93.1 76.9 60.7 91.3 91.3 75.1 58.9 65 51.6 53.8 56.8 55.9 59.2 58.1 61.6 60.1 60.0 62.2 58.5 41.6 42.9 43.6 44.2 45.0 45.5 46.3 45.0 44.5 44.5 42.7 45 528150-YTG-T-0514 ZH102 (8.5 Ton) (Continued) Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 99.3 90.7 82.0 73.9 102.5 93.6 84.7 76.3 76.1 105.7 96.5 87.3 78.7 78.4 108.9 99.4 90.0 81.1 80.8 99.9 90.4 81.5 81.2 100.4 90.8 81.9 81.6 9.3 9.0 8.8 8.6 9.4 9.1 8.8 8.7 8.7 9.4 9.1 8.9 8.7 8.8 9.5 9.2 8.9 8.8 8.8 9.3 9.0 8.9 8.9 9.4 9.1 9.0 9.0 40.7 58.3 75.8 73.9 50.5 65.5 80.5 76.3 76.1 60.2 72.7 85.3 78.7 78.4 69.9 79.9 90.0 81.1 80.8 85.5 90.4 81.5 81.2 91.0 90.8 81.9 81.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 35.5 26.4 82.4 10.1 49.2 40.1 31.0 76.9 9.7 62.9 53.8 44.7 35.6 71.4 9.4 73.9 61.6 52.5 43.4 34.3 63.1 9.2 39.8 29.1 86.4 10.2 54.8 44.1 33.5 80.6 9.8 69.9 59.2 48.5 37.8 74.8 9.4 76.3 67.7 57.1 46.4 35.7 66.1 9.3 76.1 67.6 56.9 46.2 35.6 67.3 9.3 44.0 31.8 90.4 10.2 60.5 48.2 35.9 84.3 9.8 76.9 64.6 52.3 40.0 78.1 9.5 78.7 73.9 61.7 49.4 37.1 69.1 9.3 78.4 73.8 61.5 49.2 36.9 70.3 9.4 48.3 34.4 94.4 10.3 66.1 52.2 38.3 87.9 9.9 83.9 70.0 56.1 42.3 81.5 9.5 81.1 80.1 66.2 52.4 38.5 72.1 9.4 80.8 79.9 66.0 52.2 38.3 73.3 9.4 70.6 55.7 40.8 87.0 10.0 87.4 74.7 59.8 44.9 80.6 9.6 81.5 81.0 66.1 51.2 36.3 71.4 9.5 81.2 80.8 65.9 51.0 36.1 72.6 9.6 75.1 59.2 43.3 86.0 10.1 90.8 79.4 63.5 47.6 79.8 9.8 81.9 81.9 66.0 50.1 34.2 70.6 9.6 81.6 81.6 65.7 49.8 33.9 71.9 9.7 90 33.8 52.6 71.4 63.1 45.4 60.1 74.8 66.1 67.3 57.1 67.6 78.1 69.1 70.3 68.7 75.1 81.5 72.1 73.3 79.8 80.6 71.4 72.6 84.5 79.8 70.6 71.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 29.9 21.0 43.7 34.8 25.9 57.5 48.5 39.6 30.7 63.1 53.8 44.9 35.9 34.2 23.7 49.5 39.0 28.4 64.9 54.3 43.7 33.2 66.1 60.2 49.7 39.1 67.3 59.2 48.6 38.0 38.5 26.3 55.4 43.2 30.9 72.3 60.0 47.8 35.6 69.1 66.7 54.4 42.2 70.3 65.5 53.3 41.1 42.8 28.9 61.2 47.3 33.5 79.6 65.8 51.9 38.1 72.1 72.1 59.2 45.4 73.3 71.9 58.0 44.2 65.0 50.3 35.6 80.6 69.9 55.2 40.5 71.4 71.4 57.1 42.4 72.6 71.9 57.2 42.4 68.9 53.3 37.6 79.8 74.1 58.5 42.9 70.6 70.6 55.0 39.4 71.9 71.9 56.3 40.7 65 27.0 28.5 27.5 30.0 28.9 31.5 30.3 27.6 27.7 23.8 25.1 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 46 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH120 (10 Ton) Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 2500 3000 3500 4000 4500 5000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 148.4 138.6 128.8 119.6 155.1 144.8 134.6 124.9 122.1 161.8 151.1 140.3 130.3 127.3 168.5 157.3 146.1 135.7 132.6 157.8 146.6 136.1 133.0 158.3 147.1 136.6 133.4 7.2 7.0 6.7 6.7 7.2 7.0 6.7 6.7 6.7 7.2 6.9 6.7 6.7 6.7 7.2 6.9 6.7 6.6 6.6 7.0 6.8 6.8 6.8 7.2 6.9 6.9 6.9 37.9 56.2 74.4 103.4 54.6 74.7 94.8 114.1 116.9 71.2 93.2 115.1 124.9 124.7 87.9 111.7 135.4 135.7 132.6 102.0 126.3 136.1 133.0 92.4 117.2 136.6 133.4 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 142.1 129.8 117.5 110.7 146.4 133.7 121.1 114.0 111.4 150.6 137.6 124.6 117.3 114.6 154.9 141.5 128.1 120.7 117.9 142.7 129.1 121.6 118.8 143.8 130.2 122.6 119.8 8.5 8.5 8.5 8.4 8.5 8.5 8.6 8.5 8.5 8.5 8.6 8.6 8.5 8.5 8.6 8.6 8.6 8.5 8.5 8.6 8.6 8.5 8.5 8.6 8.6 8.5 8.5 32.5 50.0 67.4 97.7 49.2 68.3 87.5 105.4 105.8 65.8 86.7 107.6 113.0 111.9 82.5 105.1 127.6 120.7 117.9 95.3 118.5 121.6 118.8 85.5 109.4 122.6 119.8 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 39.0 40.1 145.3 7.9 57.2 58.3 59.4 134.2 7.7 75.5 76.5 77.6 78.7 123.2 7.6 95.5 94.1 95.2 96.2 97.3 115.1 7.6 49.4 44.1 150.7 7.9 69.4 64.2 59.0 139.3 7.8 89.5 84.3 79.0 73.8 127.8 7.6 108.9 103.6 98.4 93.2 87.9 119.5 7.6 111.7 106.4 101.2 95.9 90.7 116.7 7.6 59.7 48.2 156.2 7.9 81.6 70.1 58.6 144.3 7.8 103.6 92.0 80.5 68.9 132.5 7.6 122.3 113.2 101.6 90.1 78.6 123.8 7.6 122.1 116.2 104.7 93.1 81.6 121.0 7.6 70.1 52.2 161.7 7.9 93.8 76.0 58.2 149.4 7.8 117.6 99.8 81.9 64.1 137.1 7.7 135.7 122.7 104.9 87.0 69.2 128.2 7.6 132.6 126.0 108.1 90.3 72.5 125.2 7.6 89.8 77.6 65.4 150.2 7.8 114.1 101.9 89.7 77.5 137.9 7.7 136.1 125.3 113.1 100.9 88.7 128.9 7.6 133.0 128.9 116.7 104.5 92.3 125.9 7.6 85.8 79.3 72.7 151.1 7.9 110.6 104.1 97.5 91.0 138.6 7.8 136.6 128.0 121.4 114.9 108.3 129.6 7.7 133.4 131.8 125.2 118.6 112.1 126.6 7.7 95°F 34.3 36.0 130.2 9.7 51.7 53.4 55.2 120.3 9.7 69.2 70.9 72.6 74.4 110.4 9.7 90.5 87.2 88.9 90.7 92.4 104.5 9.6 44.3 39.5 133.8 9.8 63.5 58.7 53.8 123.6 9.7 82.7 77.8 73.0 68.1 113.4 9.7 100.5 95.7 90.8 86.0 81.2 107.3 9.6 101.0 96.2 91.3 86.5 81.6 104.7 9.6 54.4 43.0 137.3 9.8 75.3 63.9 52.4 126.9 9.8 96.1 84.7 73.3 61.9 116.5 9.7 110.6 104.2 92.8 81.3 69.9 110.2 9.7 109.4 104.7 93.3 81.9 70.4 107.4 9.6 64.5 46.5 140.9 9.8 87.1 69.1 51.1 130.2 9.8 109.6 91.6 73.6 55.6 119.5 9.8 120.7 112.7 94.7 76.7 58.7 113.0 9.7 117.9 113.2 95.2 77.2 59.2 110.2 9.6 83.2 71.2 59.1 131.2 9.8 106.5 94.4 82.3 70.3 120.4 9.8 121.6 116.1 104.0 92.0 79.9 113.9 9.7 118.8 116.5 104.5 92.4 80.3 111.0 9.6 79.4 73.3 67.1 132.2 9.8 103.3 97.2 91.1 84.9 121.3 9.8 122.6 119.5 113.4 107.3 101.1 114.8 9.7 119.8 119.8 113.7 107.5 101.4 111.9 9.6 90 35.2 53.1 70.9 100.5 51.9 71.5 91.1 109.7 111.4 68.5 89.9 111.3 118.9 118.3 85.2 108.4 131.5 128.2 125.2 98.7 122.4 128.9 125.9 89.0 113.3 129.6 126.6 26.3 46.3 66.3 92.5 45.2 64.6 84.0 99.4 99.7 64.0 82.8 101.6 106.2 105.0 82.8 101.0 119.2 113.0 110.2 91.1 112.4 113.9 111.0 81.2 105.5 114.8 111.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 36.6 38.0 54.5 55.9 57.3 72.3 73.7 75.1 76.5 93.0 90.7 92.1 93.5 46.8 41.8 66.5 61.4 56.4 86.1 81.0 76.0 71.0 104.7 99.7 94.6 89.6 106.3 101.3 96.3 91.2 57.1 45.6 78.5 67.0 55.5 99.8 88.4 76.9 65.4 116.4 108.7 97.2 85.7 115.8 110.4 99.0 87.5 67.3 49.4 90.4 72.5 54.6 113.6 95.7 77.8 59.9 128.2 117.7 99.8 81.8 125.2 119.6 101.7 83.8 86.5 74.4 62.3 110.3 98.2 86.0 73.9 128.9 120.7 108.6 96.5 125.9 122.7 110.6 98.4 82.6 76.3 69.9 107.0 100.6 94.3 87.9 129.6 123.8 117.4 111.1 126.6 125.8 119.4 113.1 105°F 30.7 32.7 48.4 50.4 52.5 66.1 68.2 70.2 72.3 85.6 82.2 84.3 86.3 40.5 35.9 59.9 55.3 50.6 79.3 74.7 70.0 65.4 94.7 90.1 85.4 80.8 95.1 90.4 85.8 81.1 50.3 39.0 71.4 60.1 48.7 92.5 81.2 69.8 58.5 103.9 97.9 86.6 75.2 102.6 98.3 87.0 75.6 60.2 42.1 83.0 64.9 46.8 105.7 87.7 69.6 51.6 113.0 105.8 87.7 69.7 110.2 106.2 88.1 70.1 79.1 67.1 55.1 102.7 90.7 78.7 66.7 113.9 109.4 97.4 85.4 111.0 109.0 97.1 85.1 75.3 69.4 63.4 99.6 93.7 87.8 81.9 114.8 113.0 107.1 101.2 111.9 111.9 106.0 100.1 65 94.9 84.5 86.2 74.2 76.0 63.9 65.8 84.3 86.3 104.7 106.7 88.4 76.1 76.5 63.9 64.3 51.6 52.0 73.5 73.1 95.3 94.2 47 528150-YTG-T-0514 ZH120 (10 Ton) (Continued) Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 118.3 110.8 103.3 98.3 121.2 113.5 105.8 100.7 97.9 124.0 116.2 108.3 103.0 100.2 126.9 118.9 110.8 105.4 102.5 119.7 111.6 106.2 103.3 120.5 112.4 106.9 104.0 11.0 10.9 10.9 10.8 11.0 10.9 10.9 10.8 10.7 11.0 10.9 10.9 10.8 10.7 11.0 11.0 10.9 10.8 10.7 10.9 10.9 10.8 10.7 10.9 10.9 10.8 10.7 20.1 42.7 65.2 87.3 41.1 60.8 80.4 93.4 93.6 62.1 78.9 95.6 99.4 98.1 83.1 97.0 110.8 105.4 102.5 86.9 106.2 106.2 103.3 76.8 101.6 106.9 104.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 27.1 29.5 106.4 12.3 45.0 47.4 49.8 101.3 12.2 63.0 65.4 67.8 70.2 96.2 12.0 80.7 77.2 79.6 82.0 84.4 92.1 12.0 36.7 32.2 108.6 12.3 56.3 51.9 47.4 103.4 12.1 76.0 71.5 67.1 62.6 98.2 12.0 88.9 84.5 80.0 75.6 71.1 94.0 12.0 89.1 84.7 80.2 75.8 71.3 91.2 11.8 46.3 35.0 110.7 12.3 67.6 56.3 45.0 105.5 12.1 88.9 77.6 66.3 55.0 100.2 12.0 97.2 91.7 80.4 69.1 57.8 95.9 12.0 95.8 91.9 80.6 69.4 58.1 93.0 11.8 55.8 37.7 112.9 12.3 78.8 60.7 42.6 107.5 12.1 101.8 83.7 65.6 47.5 102.2 12.0 105.4 98.9 80.8 62.6 44.5 97.8 12.0 102.5 99.2 81.0 62.9 44.8 94.9 11.8 75.0 63.1 51.2 108.2 12.1 98.9 87.0 75.1 63.2 102.8 12.0 106.2 102.7 90.8 78.9 67.0 98.4 12.0 103.3 101.6 89.7 77.8 65.9 95.5 11.8 71.1 65.5 59.8 108.9 12.1 95.9 90.2 84.6 78.9 103.5 12.0 106.9 106.6 100.9 95.2 89.5 99.0 12.0 104.0 104.0 98.3 92.6 86.9 96.1 11.8 90 13.8 39.0 64.1 82.1 37.1 57.0 76.9 87.3 87.5 60.4 75.0 89.7 92.6 91.2 83.6 92.9 102.2 97.8 94.9 82.7 100.1 98.4 95.5 72.5 97.7 99.0 96.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 23.5 26.2 41.7 44.4 47.1 59.9 62.6 65.4 68.1 75.7 72.3 75.0 77.7 32.8 28.6 52.7 48.5 44.2 72.6 68.4 64.1 59.8 83.1 78.8 74.6 70.3 83.2 79.0 74.7 70.4 42.2 31.0 63.7 52.5 41.3 85.3 74.1 62.8 51.6 90.4 85.4 74.2 63.0 89.1 85.5 74.3 63.1 51.5 33.3 74.7 56.6 38.4 98.0 79.8 61.6 43.4 97.8 92.0 73.8 55.6 94.9 92.1 73.9 55.8 70.9 59.1 47.2 95.1 83.3 71.4 59.6 98.4 96.0 84.2 72.4 95.5 94.1 82.3 70.5 67.0 61.5 56.1 92.2 86.8 81.3 75.8 99.0 99.0 94.6 89.2 96.1 96.1 90.6 85.2 65 80.4 66.1 66.2 51.8 51.9 37.4 37.6 60.6 58.6 83.7 79.7 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 48 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH150 (12.5 Ton) Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 3125 3750 4375 5000 5625 6250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 204.4 186.6 168.8 153.0 210.2 191.8 173.5 157.2 152.9 215.9 197.1 178.3 161.5 157.1 221.6 202.3 183.0 165.8 161.2 206.6 186.9 169.3 164.7 210.9 190.8 172.9 168.1 9.6 9.3 9.1 9.0 9.7 9.4 9.1 9.0 8.9 9.7 9.4 9.2 9.1 9.0 9.8 9.5 9.2 9.1 9.0 9.5 9.2 9.2 9.0 9.5 9.3 9.2 9.0 82.4 106.6 130.7 153.0 89.0 114.7 140.4 157.2 152.9 95.5 122.8 150.1 161.5 157.1 102.1 130.9 159.8 165.8 161.2 140.7 174.9 169.3 164.7 150.5 190.0 172.9 168.1 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 180.0 165.5 151.0 136.9 184.8 169.9 155.0 140.5 141.0 189.6 174.3 159.0 144.2 144.6 194.4 178.7 163.0 147.8 148.3 180.4 164.5 149.2 149.7 182.1 166.1 150.6 151.1 11.6 11.4 11.3 11.0 11.7 11.5 11.4 11.1 11.0 11.8 11.6 11.5 11.2 11.1 11.9 11.7 11.6 11.3 11.2 11.7 11.6 11.3 11.2 11.8 11.6 11.3 11.3 71.9 94.9 117.8 136.9 79.6 104.6 129.6 140.5 141.0 87.3 114.3 141.4 144.2 144.6 94.9 124.1 153.2 147.8 148.3 131.9 159.6 149.2 149.7 139.7 166.1 150.6 151.1 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 68.5 54.6 192.2 10.6 92.6 78.7 64.8 176.1 10.4 116.8 102.9 88.9 75.0 159.9 10.2 143.5 127.2 113.3 99.4 85.5 144.9 10.0 73.6 58.1 197.5 10.7 99.3 83.9 68.4 180.9 10.5 125.0 109.6 94.2 78.7 164.3 10.2 150.9 135.5 120.1 104.7 89.3 148.9 10.1 152.9 144.1 128.7 113.3 97.8 146.9 10.0 78.6 61.7 202.8 10.8 105.9 89.0 72.1 185.7 10.5 133.2 116.3 99.4 82.5 168.6 10.3 158.4 143.8 126.9 110.0 93.1 152.8 10.1 157.1 152.9 136.0 119.1 102.2 150.8 10.1 83.7 65.3 208.0 10.8 112.6 94.2 75.8 190.5 10.6 141.4 123.0 104.6 86.2 173.0 10.4 165.8 152.1 133.7 115.3 96.9 156.8 10.2 161.2 161.8 143.4 125.0 106.6 154.8 10.1 121.0 101.3 81.6 193.5 10.6 152.0 132.3 112.6 92.9 175.7 10.4 169.3 162.5 142.8 123.1 103.4 159.3 10.2 164.7 165.0 145.3 125.6 105.8 157.2 10.1 129.4 108.4 87.4 196.5 10.6 162.7 141.6 120.6 99.6 178.4 10.4 172.9 172.9 151.8 130.8 109.8 161.7 10.2 168.1 168.1 147.1 126.1 105.0 159.6 10.2 95°F 58.7 45.5 169.2 13.1 81.7 68.5 55.2 155.1 13.0 104.6 91.4 78.2 65.0 140.9 12.8 133.3 113.0 99.8 86.6 73.4 128.7 12.5 64.6 49.6 173.5 13.2 89.6 74.6 59.6 159.0 13.0 114.6 99.6 84.6 69.6 144.5 12.8 138.1 123.1 108.1 93.1 78.1 131.9 12.6 141.0 126.3 111.3 96.3 81.3 131.4 12.6 70.5 53.7 177.8 13.2 97.5 80.7 63.9 162.9 13.1 124.6 107.8 91.0 74.2 148.1 12.9 143.0 133.3 116.5 99.7 82.9 135.2 12.6 144.6 136.7 119.9 103.1 86.3 134.6 12.6 76.3 57.7 182.0 13.3 105.5 86.9 68.3 166.8 13.1 134.6 116.0 97.4 78.8 151.6 12.9 147.8 143.4 124.8 106.2 87.6 138.4 12.7 148.3 147.1 128.5 109.9 91.3 137.8 12.7 112.0 92.2 72.3 168.0 13.2 142.9 123.1 103.2 83.3 152.7 13.0 149.2 147.0 127.1 107.3 87.4 139.4 12.7 149.7 149.1 129.2 109.4 89.5 138.8 12.7 118.6 97.4 76.3 169.2 13.2 151.3 130.1 109.0 87.9 153.7 13.0 150.6 150.6 129.5 108.3 87.2 140.4 12.7 151.1 151.1 130.0 108.8 87.7 139.8 12.7 90 77.2 100.7 124.3 144.9 84.3 109.7 135.0 148.9 146.9 91.4 118.6 145.8 152.8 150.8 98.5 127.5 156.5 156.8 154.8 136.3 167.3 159.3 157.2 145.1 178.0 161.7 159.6 68.8 91.6 114.3 128.7 76.3 100.7 125.1 131.9 131.4 83.9 109.9 135.9 135.2 134.6 91.5 119.1 146.7 138.4 137.8 127.6 150.2 139.4 138.8 136.0 153.7 140.4 139.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 63.6 50.0 87.2 73.6 60.0 110.7 97.1 83.6 70.0 138.4 120.1 106.6 93.0 69.1 53.9 94.4 79.2 64.0 119.8 104.6 89.4 74.2 144.5 129.3 114.1 98.9 146.9 135.2 120.0 104.8 74.5 57.7 101.7 84.9 68.0 128.9 112.0 95.2 78.3 150.7 138.5 121.7 104.8 150.8 144.8 128.0 111.1 80.0 61.5 109.0 90.5 72.0 138.0 119.5 101.0 82.5 156.8 147.8 129.3 110.8 154.8 154.5 136.0 117.5 116.5 96.7 76.9 147.5 127.7 107.9 88.1 159.3 154.7 135.0 115.2 157.2 157.0 137.2 117.5 124.0 102.9 81.8 157.0 135.9 114.8 93.7 161.7 161.7 140.6 119.6 159.6 159.6 138.5 117.4 105°F 56.1 43.0 78.5 65.5 52.4 100.9 87.9 74.9 61.8 126.9 108.9 95.8 82.8 61.6 46.8 86.0 71.2 56.5 110.4 95.6 80.9 66.1 130.7 118.4 103.7 88.9 131.4 118.3 103.5 88.8 67.1 50.6 93.4 77.0 60.5 119.8 103.3 86.9 70.4 134.6 128.0 111.5 95.0 134.6 127.8 111.4 94.9 72.6 54.4 100.9 82.7 64.5 129.2 111.0 92.9 74.7 138.4 137.5 119.3 101.1 137.8 137.4 119.2 101.0 107.9 88.2 68.6 137.8 118.5 98.8 79.1 139.4 138.9 119.3 99.6 138.8 138.6 118.9 99.3 114.9 93.8 72.6 146.3 125.9 104.8 83.6 140.4 140.4 119.2 98.1 139.8 139.8 118.6 97.5 65 79.4 83.7 89.6 88.0 94.3 92.3 99.0 95.4 97.7 98.5 96.4 69.8 74.1 74.0 78.5 78.4 82.9 82.8 80.0 79.6 77.0 76.4 49 528150-YTG-T-0514 ZH150 (12.5 Ton) (Continued) Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 158.4 144.6 130.9 120.5 162.2 148.1 134.0 123.3 121.8 165.9 151.5 137.1 126.2 124.6 169.7 155.0 140.2 129.1 127.4 155.6 140.8 129.6 127.9 156.2 141.4 130.1 128.4 14.6 14.5 14.3 14.0 14.7 14.5 14.3 14.1 14.1 14.7 14.5 14.3 14.1 14.1 14.7 14.5 14.3 14.1 14.2 14.6 14.4 14.1 14.2 14.6 14.4 14.2 14.2 65.6 88.2 110.9 120.5 73.1 96.9 120.6 123.3 121.8 80.6 105.5 130.4 126.2 124.6 88.1 114.2 140.2 129.1 127.4 123.2 140.8 129.6 127.9 132.3 141.4 130.1 128.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 53.5 40.6 147.6 16.1 75.4 62.5 49.6 134.2 16.0 97.3 84.4 71.5 58.7 120.9 15.8 120.5 104.7 91.9 79.0 66.1 112.3 15.6 58.6 44.1 150.8 16.1 82.4 67.9 53.3 137.2 16.0 106.1 91.6 77.1 62.6 123.5 15.8 123.3 113.7 99.2 84.7 70.2 114.8 15.6 121.8 110.3 95.8 81.2 66.7 112.1 15.6 63.7 47.6 154.1 16.1 89.4 73.2 57.1 140.1 15.9 115.0 98.9 82.7 66.6 126.2 15.8 126.2 122.7 106.5 90.4 74.2 117.2 15.5 124.6 119.0 102.8 86.7 70.5 114.6 15.6 68.8 51.0 157.3 16.1 96.4 78.6 60.8 143.1 15.9 123.9 106.1 88.3 70.5 128.9 15.7 129.1 131.7 113.9 96.1 78.3 119.7 15.5 127.4 127.7 109.9 92.1 74.3 117.0 15.6 103.8 84.3 64.9 143.2 16.0 132.6 113.9 94.4 74.9 128.9 15.8 129.6 130.9 111.4 92.0 72.5 119.8 15.6 127.9 128.1 108.6 89.1 69.7 117.0 15.6 111.2 90.1 69.0 143.3 16.0 141.4 121.6 100.5 79.4 129.0 15.8 130.1 130.1 109.0 87.9 66.8 119.9 15.6 128.4 128.4 107.3 86.2 65.1 117.1 15.7 90 60.0 84.9 107.4 112.3 69.9 93.0 116.2 114.8 112.1 79.7 101.1 125.0 117.2 114.6 89.6 109.2 128.9 119.7 117.0 118.9 128.9 119.8 117.0 128.6 129.0 119.9 117.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 50.8 38.1 72.2 59.5 46.8 93.6 80.9 68.2 55.5 112.3 100.7 87.9 75.2 55.6 41.3 78.7 64.5 50.2 101.9 87.6 73.4 59.1 114.8 109.0 94.7 80.5 112.1 102.2 88.0 73.7 60.3 44.5 85.3 69.5 53.6 110.2 94.4 78.6 62.7 117.2 117.2 101.6 85.7 114.6 110.1 94.3 78.4 65.1 47.7 91.8 74.4 57.0 118.6 101.1 83.7 66.3 119.7 119.7 108.4 91.0 117.0 117.0 100.6 83.2 99.7 80.4 61.2 127.5 109.3 90.0 70.8 119.8 119.8 103.6 84.3 117.0 117.0 98.3 79.0 107.5 86.4 65.3 129.0 117.4 96.3 75.2 119.9 119.9 98.8 77.7 117.1 117.1 96.0 74.9 65 62.5 66.2 59.4 69.9 62.6 73.6 65.7 65.1 59.8 56.5 53.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 50 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ037-150 Cooling Capacities ZJ037 (3.0 Ton) Air on Evaporator Coil CFM 750 900 1050 1200 1350 1500 750 900 1050 1200 1350 1500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 49.2 43.8 38.4 33.2 51.6 45.9 40.3 34.8 29.4 54.0 48.1 42.2 36.4 30.8 56.4 50.2 44.1 38.1 32.2 51.5 45.1 39.0 33.0 52.7 46.2 39.9 33.8 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 19.7 24.5 29.4 33.2 22.2 27.6 33.0 34.8 29.4 24.8 30.7 36.6 36.4 30.8 27.4 33.8 40.2 38.1 32.2 36.7 43.2 39.0 33.0 39.6 46.2 39.9 33.8 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 41.1 36.5 31.9 27.6 43.3 38.5 33.6 29.0 28.3 45.4 40.4 35.3 30.5 29.7 47.6 42.3 37.0 32.0 31.2 43.0 37.6 32.4 31.6 43.6 38.1 32.9 32.1 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.4 2.6 2.5 2.5 2.4 2.4 2.6 2.5 2.5 2.4 2.4 2.5 2.5 2.4 2.4 2.5 2.5 2.4 2.4 16.4 21.0 25.6 27.6 18.9 24.1 29.3 29.0 28.3 21.4 27.2 32.9 30.5 29.7 23.9 30.2 36.6 32.0 31.2 32.8 37.4 32.4 31.6 35.4 38.1 32.9 32.1 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 16.4 13.1 45.1 2.3 21.2 17.9 14.6 40.2 2.3 26.1 22.8 19.5 16.2 35.2 2.2 33.2 27.2 23.9 20.6 17.3 30.4 2.2 18.3 14.5 47.4 2.3 23.7 19.8 15.9 42.2 2.3 29.1 25.2 21.3 17.4 37.0 2.2 34.8 30.1 26.2 22.3 18.4 31.9 2.2 29.4 31.7 27.8 23.9 20.0 28.9 2.2 20.3 15.8 49.7 2.3 26.2 21.7 17.3 44.2 2.3 32.1 27.6 23.2 18.7 38.7 2.2 36.4 33.0 28.5 24.0 19.5 33.5 2.2 30.8 38.9 32.1 29.9 25.4 30.3 2.2 22.3 17.2 52.0 2.3 28.7 23.7 18.6 46.3 2.3 35.2 30.1 25.0 19.9 40.5 2.2 38.1 35.9 30.8 25.7 20.6 35.0 2.2 32.2 46.0 36.4 35.8 30.7 31.7 2.2 31.0 25.4 19.7 47.2 2.3 37.9 32.3 26.6 20.9 41.3 2.2 39.0 37.9 32.2 26.6 20.9 35.7 2.2 33.0 39.9 31.9 28.6 22.9 32.3 2.2 33.3 27.1 20.9 48.1 2.3 40.7 34.4 28.2 22.0 42.2 2.2 39.9 39.9 33.7 27.4 21.2 36.4 2.2 33.8 33.8 27.5 21.3 15.0 32.9 2.2 95°F 13.3 10.2 36.8 2.8 17.9 14.8 11.7 32.9 2.7 22.5 19.4 16.3 13.2 28.9 2.7 27.6 23.3 20.2 17.1 14.0 24.9 2.6 15.2 11.5 38.6 2.8 20.4 16.7 13.0 34.5 2.7 25.6 21.9 18.1 14.4 30.3 2.7 29.0 26.2 22.5 18.8 15.1 26.1 2.6 28.3 26.0 22.3 18.6 14.9 25.5 2.6 17.1 12.7 40.4 2.8 22.8 18.5 14.2 36.1 2.8 28.6 24.3 20.0 15.7 31.7 2.7 30.5 29.1 24.8 20.5 16.2 27.3 2.6 29.7 29.0 24.6 20.3 16.0 26.7 2.6 19.0 14.0 42.2 2.9 25.3 20.4 15.5 37.7 2.8 31.7 26.8 21.8 16.9 33.1 2.7 32.0 32.1 27.2 22.2 17.3 28.5 2.6 31.2 31.9 27.0 22.0 17.1 27.9 2.7 27.4 21.9 16.5 38.2 2.8 34.2 28.7 23.3 17.9 33.6 2.7 32.4 32.5 27.1 21.6 16.2 28.9 2.7 31.6 32.0 26.6 21.1 15.7 28.3 2.7 29.4 23.4 17.5 38.7 2.8 36.7 30.7 24.8 18.8 34.0 2.7 32.9 32.9 27.0 21.0 15.1 29.3 2.7 32.1 32.1 26.2 20.2 14.2 28.7 2.7 90 18.0 22.8 27.5 30.4 20.6 25.9 31.1 31.9 28.9 23.1 28.9 34.8 33.5 30.3 25.6 32.0 38.4 35.0 31.7 34.8 40.3 35.7 32.3 37.5 42.2 36.4 32.9 13.8 19.3 24.9 24.9 16.9 22.2 27.6 26.1 25.5 20.0 25.1 30.2 27.3 26.7 23.1 28.0 32.9 28.5 27.9 30.5 33.5 28.9 28.3 32.9 34.0 29.3 28.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 14.8 11.6 19.6 16.4 13.2 24.3 21.1 17.9 14.7 30.4 25.3 22.0 18.8 16.8 13.0 22.1 18.3 14.4 27.3 23.5 19.7 15.9 31.9 28.2 24.4 20.6 28.9 28.9 25.1 21.3 18.7 14.3 24.5 20.1 15.7 30.4 26.0 21.6 17.2 33.5 31.1 26.7 22.3 30.3 33.9 28.4 25.1 20.6 15.6 27.0 22.0 17.0 33.4 28.4 23.4 18.4 35.0 34.0 29.0 24.0 31.7 38.9 31.7 28.9 29.2 23.6 18.1 36.1 30.5 24.9 19.4 35.7 35.2 29.6 24.1 32.3 35.9 29.3 24.8 31.4 25.3 19.2 38.7 32.6 26.5 20.4 36.4 36.4 30.3 24.2 32.9 32.9 26.8 20.7 105°F 11.6 8.6 16.3 13.3 10.3 21.0 18.0 15.0 12.0 24.9 21.8 18.8 15.8 13.3 9.7 18.6 15.0 11.4 24.0 20.4 16.8 13.2 26.1 24.6 21.0 17.4 25.5 23.6 20.0 16.4 15.0 10.8 20.9 16.8 12.6 26.9 22.7 18.5 14.3 27.3 27.4 23.3 19.1 26.7 26.4 22.2 18.0 16.7 11.9 23.3 18.5 13.7 29.8 25.0 20.3 15.5 28.5 30.3 25.5 20.7 27.9 29.1 24.3 19.5 25.2 19.9 14.6 31.6 27.0 21.7 16.4 28.9 29.8 24.5 19.2 28.3 28.9 23.6 18.3 27.1 21.3 15.5 33.3 28.9 23.0 17.2 29.3 29.3 23.5 17.6 28.7 28.7 22.9 17.0 65 15.6 16.8 17.5 17.9 20.7 19.0 23.9 18.5 19.3 18.1 14.6 12.8 13.8 12.8 14.9 13.8 15.9 14.7 13.9 13.0 11.8 11.2 51 528150-YTG-T-0514 ZJ037 (3.0 Ton) (Continued) Air on Evaporator Coil CFM 750 900 1050 1200 1350 1500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 32.6 29.2 25.9 22.2 34.0 30.5 27.0 23.1 22.8 35.4 31.8 28.1 24.1 23.7 36.8 33.0 29.2 25.0 24.7 33.4 29.6 25.3 24.9 33.8 29.9 25.6 25.2 3.1 3.0 2.9 2.8 3.1 3.0 2.9 2.8 2.8 3.1 3.0 2.9 2.8 2.9 3.1 3.0 2.9 2.8 2.9 3.0 2.9 2.9 2.9 3.1 3.0 2.9 2.9 11.2 17.7 24.2 22.2 14.9 20.4 25.9 23.1 22.8 18.7 23.1 27.5 24.1 23.7 22.4 25.8 29.2 25.0 24.7 28.2 29.6 25.3 24.9 30.5 29.9 25.6 25.2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 9.9 7.0 28.3 3.3 14.8 11.8 8.9 25.6 3.2 19.6 16.6 13.7 10.8 22.9 3.1 22.2 20.3 17.4 14.4 11.5 19.5 3.0 11.4 7.9 29.4 3.4 16.9 13.4 9.9 26.5 3.2 22.4 18.9 15.4 11.9 23.7 3.1 23.1 23.0 19.5 16.0 12.5 20.2 3.0 22.8 21.2 17.8 14.3 10.8 20.0 3.1 12.9 8.9 30.4 3.4 19.1 15.0 10.9 27.5 3.3 25.2 21.1 17.0 13.0 24.5 3.1 24.1 25.7 21.7 17.6 13.6 20.9 3.0 23.7 23.8 19.7 15.6 11.6 20.7 3.1 14.5 9.8 31.4 3.4 21.2 16.6 12.0 28.4 3.3 28.0 23.3 18.7 14.1 25.4 3.1 25.0 28.5 23.8 19.2 14.6 21.6 3.0 24.7 26.3 21.6 17.0 12.4 21.4 3.1 23.0 17.9 12.7 28.6 3.3 28.9 25.2 20.0 14.9 25.6 3.2 25.3 27.0 21.9 16.7 11.6 21.8 3.1 24.9 25.7 20.6 15.4 10.3 21.6 3.1 24.8 19.2 13.5 28.9 3.3 29.9 27.0 21.3 15.6 25.8 3.2 25.6 25.6 19.9 14.3 8.6 22.0 3.1 25.2 25.2 19.6 13.9 8.2 21.8 3.2 90 9.2 16.0 22.9 19.5 13.4 18.6 23.7 20.2 20.0 17.6 21.1 24.5 20.9 20.7 21.9 23.6 25.4 21.6 21.4 25.9 25.6 21.8 21.6 28.1 25.8 22.0 21.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 7.9 5.4 13.2 10.3 7.5 18.1 15.3 12.4 9.6 19.5 19.5 16.0 13.1 9.6 6.2 15.2 11.8 8.4 20.8 17.4 14.0 10.6 20.2 20.2 18.0 14.7 20.0 18.8 15.5 12.1 11.3 7.0 17.2 13.2 9.3 23.4 19.5 15.6 11.7 20.9 20.9 20.1 16.2 20.7 20.7 17.2 13.3 12.9 7.7 19.1 14.7 10.2 25.4 21.6 17.2 12.7 21.6 21.6 21.6 17.7 21.4 21.4 19.0 14.5 20.9 15.9 10.9 25.6 23.4 18.4 13.4 21.8 21.8 19.3 14.3 21.6 21.6 17.6 12.6 22.6 17.0 11.5 25.8 25.1 19.6 14.0 22.0 22.0 16.4 10.9 21.8 21.8 16.2 10.7 65 10.3 11.3 8.7 12.2 9.4 13.2 10.0 9.3 7.6 5.4 5.2 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 52 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ049 (4.0 Ton) Air on Evaporator Coil CFM 1000 1200 1400 1600 1800 2000 1000 1200 1400 1600 1800 2000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 79.0 68.7 58.4 54.5 78.9 68.5 58.2 54.4 54.2 78.8 68.4 58.0 54.4 54.2 78.7 68.2 57.8 54.3 54.1 62.0 52.4 49.5 49.3 55.8 47.0 44.6 44.6 3.0 2.9 2.8 2.9 3.0 2.9 2.8 2.9 2.9 2.9 2.9 2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 3.2 3.1 3.2 3.2 3.5 3.5 3.5 3.5 29.4 35.7 42.0 54.5 32.6 39.4 46.2 54.4 54.2 35.8 43.0 50.3 54.4 54.2 38.9 46.7 54.5 54.3 54.1 44.6 50.8 49.5 49.3 42.4 47.0 44.6 44.6 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 52.8 47.4 41.9 36.1 56.2 50.4 44.6 38.4 37.7 59.6 53.4 47.3 40.7 40.0 63.0 56.5 50.0 43.0 42.3 56.7 50.1 43.2 42.4 56.9 50.3 43.3 42.6 3.4 3.4 3.4 3.3 3.5 3.5 3.4 3.3 3.3 3.5 3.5 3.5 3.4 3.4 3.6 3.5 3.5 3.4 3.4 3.5 3.5 3.4 3.4 3.5 3.5 3.4 3.4 23.9 29.8 35.7 36.1 27.2 33.7 40.3 38.4 37.7 30.5 37.7 44.9 40.7 40.0 33.8 41.6 49.4 43.0 42.3 44.9 49.9 43.2 42.4 48.3 50.3 43.3 42.6 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 25.1 20.7 65.9 3.2 31.3 27.0 22.6 58.0 3.2 37.6 33.3 28.9 24.5 50.1 3.1 51.1 39.9 35.5 31.2 26.8 45.3 3.1 27.5 22.4 67.5 3.2 34.3 29.2 24.1 59.5 3.2 41.1 36.0 30.9 25.8 51.4 3.1 52.2 43.1 38.0 32.9 27.8 46.4 3.1 54.2 46.4 41.3 36.2 31.1 46.0 3.1 29.9 24.1 69.2 3.2 37.2 31.4 25.5 60.9 3.2 44.5 38.7 32.8 27.0 52.6 3.1 53.2 46.3 40.5 34.7 28.8 47.5 3.1 54.2 50.0 44.1 38.3 32.4 47.1 3.1 32.4 25.8 70.8 3.2 40.1 33.6 27.0 62.3 3.2 47.9 41.4 34.8 28.2 53.9 3.1 54.3 49.6 43.0 36.4 29.8 48.7 3.1 54.1 53.5 46.9 40.3 33.8 48.2 3.1 37.0 29.5 22.0 59.3 3.4 43.8 36.2 28.7 21.2 51.3 3.3 49.5 47.0 39.5 32.0 24.5 46.3 3.3 49.3 49.0 41.5 34.0 26.5 45.9 3.3 33.9 25.5 17.0 56.3 3.5 39.6 31.1 22.7 14.2 48.7 3.5 44.6 44.4 36.0 27.5 19.1 44.0 3.5 44.6 44.6 36.1 27.6 19.2 43.6 3.5 95°F 19.7 15.5 49.1 3.8 25.6 21.5 17.3 43.6 3.8 31.6 27.4 23.2 19.0 38.1 3.7 36.1 33.7 29.6 25.4 21.2 33.9 3.6 22.2 17.2 51.6 3.9 28.8 23.8 18.8 45.8 3.8 35.3 30.3 25.4 20.4 40.0 3.7 38.4 37.4 32.4 27.4 22.4 35.6 3.6 37.7 36.8 31.9 26.9 21.9 35.2 3.6 24.7 18.9 54.0 3.9 31.9 26.1 20.3 48.0 3.8 39.1 33.3 27.5 21.7 42.0 3.8 40.7 41.0 35.2 29.4 23.7 37.3 3.7 40.0 40.4 34.6 28.8 23.1 36.8 3.7 27.2 20.6 56.5 3.9 35.0 28.4 21.8 50.2 3.9 42.8 36.2 29.6 23.0 43.9 3.8 43.0 44.7 38.1 31.5 24.9 39.0 3.7 42.3 44.0 37.4 30.8 24.2 38.5 3.7 37.6 30.3 23.0 49.9 3.9 46.0 38.7 31.4 24.0 43.7 3.8 43.2 44.0 36.7 29.4 22.1 38.7 3.7 42.4 43.3 36.0 28.7 21.3 38.3 3.7 40.3 32.2 24.2 49.7 3.9 49.1 41.1 33.1 25.1 43.4 3.8 43.3 43.3 35.3 27.3 19.2 38.5 3.7 42.6 42.6 34.5 26.5 18.5 38.1 3.7 90 26.7 32.8 38.9 45.3 29.9 36.6 43.2 46.4 46.0 33.1 40.4 47.6 47.5 47.1 36.4 44.2 52.0 48.7 48.2 44.7 50.3 46.3 45.9 45.3 48.7 44.0 43.6 19.3 27.0 34.7 33.9 24.5 31.1 37.7 35.6 35.2 29.6 35.1 40.7 37.3 36.8 34.7 39.2 43.6 39.0 38.5 42.3 43.5 38.7 38.3 45.4 43.4 38.5 38.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 22.4 18.1 28.5 24.2 20.0 34.6 30.3 26.1 21.8 43.6 36.8 32.6 28.3 24.8 19.8 31.5 26.5 21.4 38.2 33.1 28.1 23.1 45.3 40.3 35.2 30.2 46.0 41.6 36.6 31.6 27.3 21.5 34.5 28.7 22.9 41.8 36.0 30.2 24.3 47.0 43.7 37.9 32.1 47.1 45.2 39.4 33.6 29.8 23.2 37.6 31.0 24.4 45.4 38.8 32.2 25.6 48.7 47.1 40.5 33.9 48.2 48.7 42.1 35.6 37.3 29.9 22.5 44.9 37.5 30.0 22.6 46.3 45.5 38.1 30.7 45.9 46.1 38.7 31.3 37.1 28.9 20.6 44.4 36.1 27.9 19.6 44.0 43.9 35.6 27.4 43.6 43.6 35.3 27.1 105°F 16.9 13.0 22.9 18.9 14.8 28.9 24.7 20.7 16.6 33.9 29.9 25.8 21.8 19.5 14.6 26.1 21.2 16.2 32.7 27.8 22.8 17.9 35.6 33.6 28.7 23.7 35.2 33.2 28.3 23.3 22.1 16.1 29.3 23.5 17.7 36.5 30.8 25.0 19.2 37.3 37.3 31.5 25.6 36.8 36.9 31.0 25.2 24.7 17.7 32.5 25.8 19.1 40.3 33.9 27.2 20.5 39.0 41.0 34.3 27.6 38.5 40.5 33.8 27.1 35.1 27.6 20.2 41.6 36.3 28.9 21.5 38.7 39.7 32.3 24.9 38.3 39.3 31.9 24.4 37.6 29.5 21.3 42.8 38.7 30.6 22.4 38.5 38.5 30.4 22.2 38.1 38.1 29.9 21.8 65 24.0 25.1 26.5 26.2 27.8 27.4 29.0 23.3 23.9 19.1 18.8 17.7 18.8 18.4 19.8 19.4 20.9 20.4 17.5 17.0 14.1 13.6 53 528150-YTG-T-0514 ZJ049 (4.0 Ton) (Continued) Air on Evaporator Coil CFM 1000 1200 1400 1600 1800 2000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 45.4 39.8 34.3 31.6 46.9 41.2 35.5 32.7 32.6 48.5 42.6 36.7 33.8 33.7 50.1 43.9 37.8 34.9 34.8 43.2 37.2 34.3 34.2 42.4 36.5 33.7 33.6 4.2 4.1 4.0 3.9 4.3 4.1 4.0 3.9 3.9 4.3 4.2 4.1 4.0 4.0 4.3 4.2 4.1 4.0 4.0 4.2 4.1 4.0 4.0 4.3 4.1 4.0 4.0 14.8 24.2 33.7 31.6 21.7 28.4 35.1 32.7 32.6 28.7 32.6 36.4 33.8 33.7 35.7 36.8 37.8 34.9 34.8 39.6 37.2 34.3 34.2 42.4 36.5 33.7 33.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 14.2 10.4 41.7 4.6 20.2 16.3 12.3 36.1 4.4 26.3 22.1 18.1 14.1 30.5 4.3 31.6 26.1 22.1 18.1 14.2 29.4 4.2 16.8 11.9 42.3 4.6 23.5 18.6 13.7 36.6 4.5 30.1 25.2 20.3 15.4 30.9 4.3 32.7 29.8 24.9 20.0 15.1 29.9 4.2 32.6 29.6 24.7 19.8 14.9 30.0 4.2 19.5 13.4 43.0 4.7 26.7 20.9 15.0 37.1 4.5 34.0 28.4 22.5 16.7 31.3 4.3 33.8 33.5 27.7 21.8 16.0 30.3 4.3 33.7 33.3 27.4 21.6 15.7 30.5 4.3 22.1 14.9 43.6 4.7 30.0 23.2 16.4 37.7 4.5 37.8 31.5 24.7 17.9 31.8 4.4 34.9 37.3 30.5 23.7 16.9 30.8 4.3 34.8 37.0 30.2 23.4 16.6 31.0 4.3 32.5 25.0 17.4 36.5 4.6 37.2 33.9 26.4 18.9 30.7 4.4 34.3 35.5 27.9 20.4 12.9 29.9 4.3 34.2 35.3 27.8 20.2 12.7 30.1 4.3 35.0 26.7 18.5 35.2 4.6 36.5 36.3 28.1 19.8 29.7 4.4 33.7 33.7 25.4 17.2 8.9 28.9 4.4 33.6 33.6 25.3 17.0 8.8 29.1 4.4 90 12.4 21.4 30.5 29.4 20.6 25.7 30.9 29.9 30.0 28.8 30.1 31.3 30.3 30.5 37.0 34.4 31.8 30.8 31.0 36.5 30.7 29.9 30.1 35.2 29.7 28.9 29.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 9.6 7.9 17.5 13.6 9.8 23.8 19.4 15.5 11.6 29.4 22.3 18.4 14.5 14.1 9.3 20.9 16.0 11.1 27.6 22.7 17.8 12.9 29.9 26.0 21.1 16.3 30.0 26.0 21.1 16.2 18.7 10.7 24.2 18.3 12.4 31.3 25.9 20.0 14.1 30.3 29.8 23.9 18.0 30.5 29.7 23.9 18.0 23.2 12.0 27.5 20.6 13.7 31.8 29.2 22.3 15.4 30.8 30.8 26.7 19.8 31.0 31.0 26.6 19.7 29.9 22.3 14.7 30.7 30.7 23.9 16.3 29.9 29.9 23.6 15.9 30.1 30.1 23.7 16.0 32.4 24.0 15.6 29.7 29.7 25.5 17.1 28.9 28.9 20.5 12.1 29.1 29.1 20.7 12.3 65 10.6 11.4 11.3 12.1 12.1 12.9 12.8 8.3 8.4 3.7 3.9 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 54 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ061 (5.0 Ton) Air on Evaporator Coil CFM 1250 1500 1750 2000 2250 2500 1250 1500 1750 2000 2250 2500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 79.8 72.2 64.6 57.1 83.4 75.5 67.5 59.7 59.9 87.0 78.8 70.5 62.3 62.4 90.6 82.0 73.4 64.9 65.0 84.2 75.4 66.6 66.8 86.4 77.3 68.4 68.5 3.1 3.1 3.2 3.1 3.1 3.2 3.2 3.1 3.2 3.2 3.2 3.2 3.1 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 35.0 42.9 50.8 57.1 38.6 47.8 57.1 59.7 59.9 42.3 52.8 63.3 62.3 62.4 45.9 57.7 69.5 64.9 65.0 62.2 73.4 66.6 66.8 66.8 77.3 68.4 68.5 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 68.5 62.1 55.7 50.1 71.1 64.5 57.8 52.0 49.8 73.7 66.8 59.9 53.9 51.6 76.3 69.2 62.0 55.8 53.4 70.6 63.3 57.0 54.5 72.0 64.6 58.1 55.7 4.1 4.1 4.0 4.0 4.1 4.1 4.1 4.0 4.0 4.2 4.1 4.1 4.0 4.0 4.2 4.1 4.1 4.0 4.0 4.2 4.1 4.0 4.0 4.2 4.1 4.0 4.0 29.0 37.6 46.2 50.1 33.4 42.4 51.5 52.0 49.8 37.8 47.3 56.7 53.9 51.6 42.2 52.1 62.0 55.8 53.4 56.4 63.3 57.0 54.5 60.7 64.6 58.1 55.7 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 28.5 22.5 74.2 3.6 36.9 30.9 24.9 67.2 3.6 45.3 39.3 33.2 27.2 60.1 3.6 57.1 47.4 41.4 35.4 29.4 53.6 3.5 31.7 24.8 77.3 3.6 40.9 34.0 27.1 70.0 3.6 50.1 43.2 36.3 29.3 62.7 3.6 59.7 52.2 45.2 38.3 31.4 55.9 3.5 59.9 55.9 49.0 42.0 35.1 54.8 3.6 34.9 27.0 80.4 3.7 44.9 37.1 29.2 72.8 3.7 55.0 47.1 39.3 31.4 65.2 3.6 62.3 56.9 49.1 41.2 33.4 58.1 3.6 62.4 61.0 53.2 45.3 37.5 57.0 3.6 38.0 29.3 83.5 3.7 48.9 40.2 31.4 75.6 3.7 59.8 51.1 42.3 33.6 67.7 3.7 64.9 61.7 52.9 44.2 35.4 60.4 3.6 65.0 66.1 57.4 48.6 39.9 59.2 3.6 52.6 43.0 33.4 77.4 3.7 64.3 54.7 45.1 35.5 69.3 3.7 66.6 65.0 55.4 45.8 36.2 61.8 3.6 66.8 67.3 57.7 48.1 38.5 60.7 3.6 56.3 45.9 35.5 79.2 3.7 68.8 58.3 47.9 37.5 70.9 3.7 68.4 68.4 57.9 47.5 37.1 63.2 3.6 68.5 68.5 58.1 47.6 37.2 62.1 3.6 95°F 23.9 18.2 63.5 4.5 32.0 26.4 20.8 57.3 4.4 40.1 34.5 28.9 23.3 51.0 4.4 50.1 41.9 36.3 30.7 25.1 46.7 4.3 26.8 20.3 65.8 4.5 35.9 29.3 22.7 59.3 4.5 44.9 38.3 31.8 25.2 52.8 4.4 52.0 46.6 40.0 33.4 26.9 48.4 4.3 49.8 44.8 38.2 31.7 25.1 46.4 4.3 29.8 22.3 68.1 4.6 39.7 32.2 24.7 61.4 4.5 49.7 42.2 34.7 27.2 54.7 4.5 53.9 51.2 43.7 36.2 28.7 50.1 4.4 51.6 49.3 41.8 34.2 26.7 48.1 4.4 32.8 24.3 70.4 4.6 43.6 35.2 26.7 63.5 4.5 54.5 46.0 37.5 29.1 56.5 4.5 55.8 55.9 47.4 38.9 30.5 51.8 4.4 53.4 53.7 45.3 36.8 28.4 49.7 4.4 47.1 37.7 28.4 64.6 4.6 58.7 49.4 40.1 30.7 57.6 4.5 57.0 57.0 47.7 38.3 29.0 52.8 4.4 54.5 54.7 45.4 36.0 26.7 50.6 4.4 50.5 40.3 30.1 65.8 4.6 63.0 52.8 42.6 32.4 58.6 4.5 58.1 58.1 48.0 37.8 27.6 53.7 4.4 55.7 55.7 45.5 35.3 25.1 51.5 4.4 90 32.0 40.3 48.5 53.6 36.0 45.1 54.3 55.9 54.8 40.0 50.0 60.0 58.1 57.0 44.0 54.9 65.7 60.4 59.2 59.3 68.3 61.8 60.7 63.7 70.9 63.2 62.1 25.6 35.7 45.7 46.7 31.5 40.4 49.3 48.4 46.4 37.3 45.1 52.9 50.1 48.1 43.1 49.8 56.5 51.8 49.7 54.1 57.6 52.8 50.6 58.3 58.6 53.7 51.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 26.2 20.4 34.4 28.6 22.8 42.7 36.9 31.1 25.3 53.6 44.7 38.9 33.0 29.3 22.5 38.4 31.6 24.9 47.5 40.8 34.0 27.3 55.9 49.4 42.6 35.9 54.8 50.3 43.6 36.9 32.3 24.7 42.3 34.7 27.0 52.3 44.7 37.0 29.3 58.1 54.1 46.4 38.7 57.0 55.1 47.5 39.8 35.4 26.8 46.3 37.7 29.1 57.1 48.5 39.9 31.3 60.4 58.8 50.2 41.5 59.2 59.9 51.3 42.7 49.9 40.4 30.9 61.5 52.0 42.6 33.1 61.8 61.0 51.5 42.1 60.7 61.0 51.5 42.1 53.4 43.1 32.8 65.9 55.6 45.2 34.9 63.2 63.2 52.9 42.6 62.1 62.1 51.8 41.5 105°F 22.1 16.6 30.1 24.6 19.1 38.1 32.6 27.1 21.5 46.7 38.4 32.8 27.3 25.0 18.5 33.9 27.4 20.9 42.8 36.3 29.8 23.3 48.4 42.7 36.2 29.7 46.4 41.7 35.2 28.7 27.8 20.4 37.7 30.2 22.7 47.5 40.0 32.5 25.1 50.1 47.1 39.6 32.1 48.1 45.9 38.5 31.0 30.7 22.3 41.4 33.0 24.6 52.1 43.7 35.3 26.9 51.8 51.4 43.0 34.6 49.7 50.2 41.7 33.3 44.8 35.5 26.2 55.0 47.0 37.8 28.5 52.8 52.6 43.3 34.0 50.6 50.8 41.6 32.3 48.2 38.0 27.9 57.8 50.4 40.2 30.1 53.7 53.7 43.6 33.4 51.5 51.5 41.4 31.2 65 27.2 29.1 30.1 31.0 32.1 32.9 34.1 32.6 32.6 32.3 31.1 21.8 23.2 22.2 24.7 23.5 26.2 24.9 24.7 23.0 23.3 21.1 55 528150-YTG-T-0514 ZJ061 (5.0 Ton) (Continued) Air on Evaporator Coil CFM 1250 1500 1750 2000 2250 2500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 58.5 52.4 46.3 43.3 60.5 54.2 47.9 44.8 43.1 62.5 56.0 49.5 46.3 44.5 64.5 57.8 51.1 47.8 45.9 58.7 51.9 48.6 46.7 59.6 52.7 49.3 47.4 4.9 4.8 4.7 4.7 4.9 4.9 4.8 4.7 4.7 5.0 4.9 4.8 4.7 4.7 5.0 5.0 4.9 4.8 4.8 5.0 4.9 4.8 4.8 5.0 4.9 4.8 4.8 22.3 33.7 45.1 43.3 29.6 38.3 47.1 44.8 43.1 36.8 43.0 49.1 46.3 44.5 44.1 47.6 51.1 47.8 45.9 51.8 51.9 48.6 46.7 55.9 52.7 49.3 47.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 20.4 14.9 53.4 5.3 28.3 22.8 17.4 47.6 5.2 36.1 30.7 25.2 19.8 41.7 5.1 43.3 34.8 29.3 23.9 18.4 40.0 5.0 23.1 16.7 55.1 5.3 31.9 25.5 19.0 49.1 5.3 40.7 34.3 27.8 21.4 43.0 5.2 44.8 38.9 32.4 26.0 19.6 41.2 5.1 43.1 38.5 32.1 25.7 19.2 39.7 5.1 25.9 18.4 56.8 5.4 35.6 28.1 20.7 50.6 5.3 45.3 37.8 30.4 23.0 44.3 5.2 46.3 42.9 35.5 28.1 20.7 42.5 5.1 44.5 42.6 35.1 27.7 20.3 40.9 5.1 28.6 20.2 58.5 5.5 39.2 30.8 22.4 52.1 5.4 49.8 41.4 33.0 24.6 45.6 5.3 47.8 47.0 38.6 30.2 21.8 43.8 5.2 45.9 46.6 38.2 29.8 21.4 42.2 5.2 42.5 33.3 24.0 52.7 5.4 51.3 44.7 35.5 26.2 46.2 5.3 48.6 48.2 38.9 29.6 20.4 44.3 5.2 46.7 47.0 37.7 28.5 19.2 42.7 5.2 45.8 35.7 25.6 53.4 5.4 52.7 48.0 37.9 27.7 46.8 5.3 49.3 49.3 39.2 29.1 19.0 44.9 5.2 47.4 47.4 37.3 27.1 17.0 43.3 5.2 90 21.9 31.8 41.7 40.0 29.6 36.3 43.0 41.2 39.7 37.4 40.8 44.3 42.5 40.9 45.1 45.4 45.6 43.8 42.2 49.5 46.2 44.3 42.7 53.4 46.8 44.9 43.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 17.7 13.3 26.4 21.0 15.6 34.1 28.7 23.4 18.0 40.0 31.2 25.8 20.5 21.3 14.9 29.9 23.6 17.2 38.6 32.2 25.8 19.5 41.2 35.0 28.6 22.3 39.7 35.4 29.0 22.6 24.8 16.5 33.5 26.1 18.7 43.0 35.7 28.3 20.9 42.5 38.8 31.4 24.1 40.9 39.2 31.8 24.5 28.4 18.1 37.0 28.6 20.3 45.6 39.2 30.8 22.4 43.8 42.6 34.2 25.9 42.2 42.2 34.7 26.3 40.2 31.0 21.8 46.2 42.4 33.1 23.9 44.3 43.7 34.5 25.3 42.7 42.7 33.9 24.7 43.4 33.4 23.3 46.8 45.6 35.5 25.4 44.9 44.9 34.8 24.7 43.3 43.3 33.2 23.1 65 15.1 15.9 16.3 16.7 17.1 17.5 17.9 16.1 15.5 14.6 13.0 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 56 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078 (6.5 Ton) Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 1625 1950 2275 2600 2925 3250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 106.7 97.0 87.2 78.3 109.7 99.7 89.6 80.4 83.1 112.6 102.3 92.1 82.6 85.3 115.6 105.0 94.5 84.8 87.6 107.5 96.7 86.7 89.6 109.9 98.8 88.7 91.6 4.6 4.5 4.5 4.6 4.6 4.6 4.5 4.6 4.6 4.6 4.6 4.5 4.6 4.6 4.6 4.6 4.5 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 46.4 57.0 67.6 78.3 50.9 62.4 73.9 80.4 83.1 55.3 67.8 80.3 82.6 85.3 59.8 73.2 86.6 84.8 87.6 78.5 92.7 86.7 89.6 83.7 98.8 88.7 91.6 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 89.6 81.5 73.4 65.8 92.3 84.0 75.6 67.8 65.4 95.0 86.4 77.8 69.8 67.2 97.6 88.8 80.0 71.7 69.1 90.7 81.7 73.3 70.6 92.7 83.5 74.8 72.1 5.6 5.5 5.5 5.4 5.6 5.6 5.5 5.5 5.4 5.7 5.6 5.5 5.5 5.5 5.7 5.6 5.6 5.5 5.5 5.7 5.6 5.5 5.5 5.7 5.6 5.5 5.5 38.5 49.3 60.2 65.8 43.2 55.0 66.8 67.8 65.4 48.0 60.7 73.4 69.8 67.2 52.7 66.4 80.0 71.7 69.1 70.9 81.7 73.3 70.6 75.4 83.5 74.8 72.1 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 38.6 31.0 98.2 5.1 49.4 41.7 34.1 89.3 5.0 60.1 52.4 44.8 37.2 80.3 5.0 71.0 62.1 54.4 46.8 39.1 72.1 5.0 42.2 33.4 101.0 5.1 53.7 45.0 36.2 91.8 5.1 65.2 56.5 47.8 39.1 82.6 5.0 75.6 66.9 58.1 49.4 40.7 74.1 5.0 83.1 72.0 63.2 54.5 45.8 74.2 5.0 45.7 35.9 103.8 5.1 58.0 48.2 38.4 94.4 5.1 70.4 60.6 50.8 41.0 84.9 5.0 80.2 71.7 61.9 52.1 42.3 76.2 5.0 85.3 77.1 67.3 57.5 47.7 76.3 5.0 49.2 38.3 106.6 5.2 62.3 51.4 40.6 96.9 5.1 75.5 64.6 53.7 42.9 87.2 5.1 84.8 76.5 65.6 54.7 43.8 78.2 5.1 87.6 82.3 71.4 60.6 49.7 78.4 5.0 66.6 54.8 43.0 99.1 5.1 80.7 68.8 57.0 45.2 89.2 5.1 86.7 82.6 70.8 58.9 47.1 80.0 5.1 89.6 87.0 75.2 63.3 51.5 80.1 5.1 70.9 58.2 45.4 101.3 5.1 85.8 73.1 60.3 47.5 91.2 5.1 88.7 88.7 75.9 63.2 50.4 81.8 5.1 91.6 91.6 78.9 66.1 53.3 81.9 5.1 95°F 31.4 24.3 80.9 6.2 42.2 35.0 27.9 73.1 6.1 52.9 45.8 38.6 31.5 65.3 6.0 64.2 53.3 46.1 39.0 31.8 58.3 5.9 34.9 26.6 83.8 6.2 46.7 38.4 30.1 75.7 6.1 58.5 50.2 41.9 33.6 67.7 6.0 66.7 58.4 50.1 41.8 33.5 60.4 5.9 65.4 61.9 53.6 45.3 37.0 61.0 5.9 38.4 29.0 86.7 6.3 51.2 41.8 32.3 78.4 6.1 64.0 54.6 45.1 35.7 70.1 6.0 69.2 63.5 54.1 44.6 35.2 62.5 5.9 67.2 67.3 57.9 48.4 39.0 63.2 6.0 41.9 31.3 89.7 6.3 55.8 45.1 34.5 81.0 6.2 69.6 59.0 48.4 37.8 72.4 6.1 71.7 68.7 58.1 47.5 36.8 64.6 6.0 69.1 72.8 62.2 51.6 40.9 65.3 6.0 59.4 47.9 36.5 82.6 6.2 74.1 62.7 51.2 39.7 73.8 6.1 73.3 71.7 60.3 48.8 37.4 65.9 6.0 70.6 72.5 61.0 49.5 38.1 66.6 6.0 63.1 50.7 38.4 84.2 6.2 78.6 66.3 54.0 41.7 75.2 6.1 74.8 74.8 62.5 50.2 37.9 67.1 6.0 72.1 72.1 59.8 47.5 35.2 67.8 6.0 90 42.4 53.2 63.9 72.1 47.1 58.7 70.4 74.1 74.2 51.7 64.2 76.8 76.2 76.3 56.3 69.8 83.3 78.2 78.4 74.7 87.2 80.0 80.1 79.5 91.2 81.8 81.9 33.0 45.5 57.9 58.3 40.0 51.4 62.8 60.4 61.0 46.9 57.2 67.6 62.5 63.2 53.8 63.1 72.4 64.6 65.3 67.2 73.8 65.9 66.6 71.3 75.2 67.1 67.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 35.0 27.6 45.8 38.4 31.0 56.5 49.1 41.7 34.3 67.6 57.7 50.3 42.9 38.5 30.0 50.2 41.7 33.2 61.9 53.3 44.8 36.3 71.1 62.6 54.1 45.6 74.2 66.9 58.4 49.9 42.0 32.4 54.6 45.0 35.4 67.2 57.6 47.9 38.3 74.7 67.6 58.0 48.3 76.3 72.2 62.6 53.0 45.5 34.8 59.0 48.3 37.6 72.5 61.8 51.1 40.3 78.2 72.6 61.8 51.1 78.4 77.6 66.8 56.1 63.0 51.4 39.7 77.4 65.7 54.1 42.5 80.0 77.2 65.5 53.9 80.1 79.7 68.1 56.4 67.0 54.5 41.9 82.2 69.7 57.2 44.6 81.8 81.8 69.2 56.7 81.9 81.9 69.3 56.8 105°F 28.4 21.5 38.6 31.8 25.0 48.9 42.1 35.2 28.4 57.5 47.9 41.1 34.2 31.9 23.9 43.3 35.3 27.2 54.7 46.7 38.6 30.5 59.9 53.1 45.0 37.0 61.0 55.7 47.7 39.6 35.5 26.2 48.0 38.7 29.4 60.5 51.2 42.0 32.7 62.2 58.3 49.0 39.7 63.2 61.2 51.9 42.6 39.0 28.5 52.6 42.2 31.7 66.3 55.8 45.3 34.8 64.6 63.5 53.0 42.5 65.3 66.6 56.1 45.7 55.9 44.7 33.4 69.5 59.1 47.8 36.6 65.9 65.3 54.0 42.7 66.6 67.2 55.9 44.7 59.2 47.2 35.1 72.8 62.4 50.4 38.3 67.1 67.1 55.1 43.0 67.8 67.8 55.7 43.7 65 35.5 37.1 41.4 38.7 43.4 40.3 45.3 42.2 44.8 44.1 44.3 27.4 28.9 31.6 30.5 33.4 32.0 35.2 31.5 33.4 30.9 31.6 57 528150-YTG-T-0514 ZJ078 (6.5 Ton) (Continued) Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 72.1 64.6 57.2 50.7 75.3 67.5 59.8 53.0 56.6 78.5 70.4 62.3 55.3 59.1 81.7 73.3 64.9 57.5 61.5 74.5 65.9 58.5 62.5 75.7 67.0 59.4 63.5 6.8 6.6 6.4 6.3 6.8 6.6 6.5 6.4 6.4 6.8 6.7 6.5 6.4 6.4 6.9 6.7 6.6 6.4 6.5 6.7 6.6 6.5 6.5 6.8 6.6 6.5 6.5 27.6 41.6 55.6 50.7 36.7 47.7 58.7 53.0 56.6 45.8 53.8 61.8 55.3 59.1 54.9 59.9 64.9 57.5 61.5 63.6 65.9 58.5 62.5 67.3 67.0 59.4 63.5 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 25.3 18.8 63.3 7.3 35.1 28.6 22.1 56.2 7.1 44.9 38.4 31.9 25.4 49.1 6.9 50.7 42.5 36.0 29.5 23.0 43.2 6.8 28.9 21.1 66.8 7.4 39.9 32.1 24.3 59.3 7.2 50.9 43.1 35.3 27.5 51.8 7.0 53.0 47.8 40.0 32.2 24.4 45.6 6.8 56.6 49.6 41.8 34.0 26.2 52.3 6.9 32.5 23.4 70.2 7.4 44.7 35.6 26.6 62.4 7.2 56.9 47.8 38.8 29.7 54.6 7.0 55.3 53.0 43.9 34.9 25.8 48.0 6.8 59.1 55.0 46.0 36.9 27.8 55.0 6.9 36.1 25.7 73.7 7.5 49.5 39.2 28.8 65.5 7.2 62.9 52.6 42.2 31.9 57.3 7.0 57.5 58.3 47.9 37.5 27.2 50.4 6.9 61.5 60.5 50.1 39.7 29.4 57.6 7.0 52.5 41.4 30.3 66.4 7.3 65.0 55.6 44.5 33.4 58.0 7.1 58.5 58.8 47.7 36.6 25.5 51.1 6.9 62.5 62.0 50.9 39.8 28.7 58.4 7.0 55.4 43.6 31.8 67.2 7.3 67.0 58.5 46.7 34.9 58.8 7.1 59.4 59.4 47.6 35.8 23.9 51.7 7.0 63.5 63.5 51.7 39.8 28.0 59.2 7.1 90 26.5 37.8 49.1 43.2 36.3 44.1 51.8 45.6 52.3 46.1 50.3 54.6 48.0 55.0 56.0 56.6 57.3 50.4 57.6 59.9 58.0 51.1 58.4 63.2 58.8 51.7 59.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 21.1 16.1 31.6 25.4 19.2 40.9 34.7 28.5 22.3 43.2 37.2 31.0 24.8 25.9 18.4 36.5 29.0 21.4 47.1 39.6 32.1 24.5 45.6 42.5 34.9 27.4 52.3 43.4 35.9 28.4 30.7 20.7 41.5 32.6 23.7 53.4 44.5 35.6 26.7 48.0 47.8 38.9 30.0 55.0 48.9 40.0 31.1 35.5 23.0 46.4 36.2 25.9 57.3 49.4 39.1 28.9 50.4 50.4 42.8 32.6 57.6 54.3 44.1 33.8 49.0 38.1 27.2 58.0 52.0 41.1 30.2 51.1 51.1 41.5 30.6 58.4 56.8 45.8 34.9 51.6 40.0 28.4 58.8 54.7 43.1 31.5 51.7 51.7 40.1 28.5 59.2 59.2 47.6 36.0 65 18.6 19.8 20.8 21.1 22.2 22.3 23.6 19.6 24.0 16.9 24.4 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 58 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ090 (7.5 Ton) Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 1875 2250 2625 3000 3375 3750 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 125.0 113.1 101.1 88.8 131.0 118.5 106.0 93.1 93.6 137.0 123.9 110.8 97.3 97.8 142.9 129.3 115.7 101.6 102.1 132.4 118.4 104.0 104.6 135.5 121.2 106.4 107.0 5.7 5.6 5.6 5.5 5.7 5.7 5.6 5.6 5.5 5.7 5.7 5.6 5.6 5.6 5.8 5.7 5.7 5.6 5.6 5.7 5.7 5.6 5.6 5.7 5.7 5.6 5.6 53.1 65.8 78.5 88.8 59.5 73.4 87.3 93.1 93.6 65.8 80.9 96.1 97.3 97.8 72.1 88.5 104.9 101.6 102.1 95.5 113.0 104.0 104.6 102.5 121.2 106.4 107.0 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 107.8 97.6 87.4 77.1 111.8 101.2 90.6 79.9 81.1 115.7 104.8 93.8 82.8 84.0 119.7 108.3 97.0 85.6 86.8 110.7 99.2 87.5 88.8 113.1 101.3 89.4 90.7 7.0 6.9 6.7 6.6 7.1 6.9 6.8 6.7 6.6 7.1 7.0 6.8 6.7 6.7 7.2 7.0 6.9 6.8 6.7 7.0 6.9 6.8 6.7 7.0 6.9 6.8 6.8 45.3 58.6 71.9 77.1 50.8 65.4 79.9 79.9 81.1 56.3 72.1 88.0 82.8 84.0 61.8 78.9 96.0 85.6 86.8 86.0 98.6 87.5 88.8 93.0 101.3 89.4 90.7 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 44.4 35.6 116.4 6.3 57.1 48.3 39.5 105.3 6.2 69.8 61.0 52.2 43.5 94.3 6.1 88.8 73.3 64.6 55.8 47.0 83.0 6.1 49.2 39.0 121.4 6.4 63.2 52.9 42.7 109.8 6.3 77.1 66.8 56.6 46.4 98.3 6.2 93.1 80.4 70.2 59.9 49.7 86.5 6.1 93.6 87.2 77.0 66.8 56.5 87.3 6.1 54.1 42.4 126.3 6.4 69.3 57.6 45.9 114.3 6.3 84.4 72.7 61.0 49.3 102.3 6.2 97.3 87.5 75.8 64.1 52.4 90.0 6.1 97.8 94.9 83.2 71.5 59.8 90.9 6.1 59.0 45.8 131.3 6.5 75.4 62.2 49.1 118.8 6.4 91.7 78.6 65.4 52.3 106.3 6.3 101.6 94.5 81.3 68.2 55.0 93.6 6.2 102.1 102.5 89.4 76.2 63.1 94.5 6.2 80.9 66.2 51.6 121.6 6.4 98.3 83.7 69.0 54.4 108.8 6.3 104.0 100.5 85.8 71.2 56.6 95.7 6.2 104.6 104.8 90.1 75.5 60.9 96.7 6.2 86.4 70.3 54.2 124.3 6.4 104.8 88.7 72.7 56.6 111.2 6.3 106.4 106.4 90.3 74.2 58.2 97.9 6.2 107.0 107.0 90.9 74.8 58.7 98.8 6.2 95°F 36.6 27.9 99.1 7.6 49.9 41.2 32.5 89.4 7.5 63.2 54.5 45.8 37.1 79.6 7.3 77.1 67.2 58.4 49.7 41.0 70.5 7.1 40.7 30.5 102.3 7.7 55.2 45.1 35.0 92.2 7.5 69.8 59.7 49.5 39.4 82.2 7.3 79.9 73.5 63.4 53.2 43.1 72.7 7.2 81.1 72.4 62.2 52.1 42.0 75.0 7.2 44.7 33.2 105.4 7.8 60.6 49.0 37.4 95.1 7.6 76.4 64.8 53.3 41.7 84.7 7.4 82.8 79.9 68.3 56.8 45.2 75.0 7.2 84.0 78.6 67.1 55.5 43.9 77.3 7.2 48.8 35.8 108.6 7.8 65.9 52.9 39.9 97.9 7.6 83.0 70.0 57.0 44.0 87.3 7.4 85.6 86.3 73.3 60.3 47.3 77.2 7.3 86.8 84.9 71.9 58.9 45.9 79.6 7.3 71.5 57.0 42.5 99.7 7.7 89.9 75.4 60.9 46.4 88.9 7.5 87.5 87.8 73.3 58.8 44.3 78.7 7.3 88.8 87.8 73.3 58.8 44.3 81.1 7.3 77.0 61.0 45.0 101.6 7.7 96.7 80.7 64.7 48.7 90.5 7.5 89.4 89.4 73.4 57.4 41.4 80.1 7.3 90.7 90.7 74.7 58.7 42.7 82.5 7.3 90 49.2 62.2 75.2 83.0 55.1 69.4 83.6 86.5 87.3 61.1 76.5 92.0 90.0 90.9 67.0 83.7 100.4 93.6 94.5 90.7 105.8 95.7 96.7 97.7 111.2 97.9 98.8 39.5 55.1 70.7 70.5 47.3 61.7 76.1 72.7 75.0 55.1 68.3 81.4 75.0 77.3 62.9 74.8 86.7 77.2 79.6 81.7 88.6 78.7 81.1 88.6 90.5 80.1 82.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 40.5 31.7 53.5 44.7 36.0 66.5 57.7 49.0 40.3 83.0 70.3 61.5 52.8 45.0 34.8 59.2 49.0 38.8 73.4 63.3 53.1 42.9 86.5 77.0 66.8 56.6 87.3 79.8 69.6 59.4 49.4 37.8 64.9 53.3 41.7 80.4 68.8 57.1 45.5 90.0 83.7 72.0 60.4 90.9 86.8 75.1 63.5 53.9 40.8 70.6 57.6 44.5 87.4 74.3 61.2 48.1 93.6 90.4 77.3 64.2 94.5 93.7 80.6 67.6 76.2 61.6 47.0 94.1 79.5 65.0 50.4 95.7 94.1 79.6 65.0 96.7 96.3 81.7 67.2 81.7 65.7 49.6 100.8 84.7 68.7 52.7 97.9 97.9 81.9 65.8 98.8 98.8 82.8 66.8 105°F 33.4 24.8 46.5 37.9 29.3 59.6 51.0 42.4 33.8 70.5 63.1 54.5 45.9 37.3 27.3 51.7 41.7 31.6 66.0 56.0 46.0 36.0 72.7 69.3 59.3 49.3 75.0 66.9 56.9 46.9 41.1 29.7 56.8 45.4 34.0 72.5 61.1 49.6 38.2 75.0 75.5 64.1 52.7 77.3 72.9 61.5 50.1 45.0 32.2 62.0 49.1 36.3 79.0 66.1 53.3 40.4 77.2 81.8 68.9 56.0 79.6 78.9 66.1 53.2 67.4 53.0 38.6 83.6 71.3 57.0 42.6 78.7 80.9 66.6 52.2 81.1 80.7 66.4 52.0 72.8 56.9 41.0 88.2 76.5 60.7 44.8 80.1 80.1 64.3 48.4 82.5 82.5 66.7 50.8 65 44.0 46.4 49.2 48.8 51.9 51.2 54.5 50.5 52.6 49.8 50.7 37.3 39.3 36.9 41.2 38.6 43.2 40.4 37.9 37.7 32.5 34.9 59 528150-YTG-T-0514 ZJ090 (7.5 Ton) (Continued) Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 90.4 81.1 71.9 63.9 92.7 83.2 73.7 65.6 68.8 95.1 85.4 75.6 67.2 70.6 97.5 87.5 77.5 68.9 72.3 88.7 78.6 69.9 73.4 90.0 79.7 70.9 74.4 8.3 8.0 7.8 7.6 8.3 8.1 7.9 7.7 7.7 8.4 8.2 7.9 7.7 7.8 8.5 8.2 8.0 7.8 7.9 8.3 8.0 7.8 7.9 8.3 8.1 7.9 7.9 33.6 51.6 69.5 63.9 43.8 58.0 72.2 65.6 68.8 53.9 64.4 74.8 67.2 70.6 64.0 70.8 77.5 68.9 72.3 77.5 78.6 69.9 73.4 84.3 79.7 70.9 74.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 30.2 21.8 81.7 8.9 43.1 34.6 26.2 72.9 8.6 56.0 47.5 39.0 30.6 64.1 8.3 63.9 59.0 50.5 42.0 33.6 57.3 8.1 33.9 24.0 83.2 9.0 48.1 38.2 28.3 74.3 8.7 62.3 52.4 42.5 32.6 65.3 8.4 65.6 65.1 55.2 45.3 35.4 58.4 8.2 68.8 61.5 51.6 41.7 31.8 62.7 8.3 37.5 26.3 84.8 9.1 53.1 41.8 30.5 75.7 8.8 68.6 57.3 46.0 34.7 66.5 8.5 67.2 71.2 59.9 48.6 37.3 59.5 8.2 70.6 67.2 55.9 44.6 33.3 63.9 8.4 41.2 28.5 86.4 9.1 58.1 45.4 32.6 77.1 8.8 74.9 62.2 49.5 36.8 67.8 8.6 68.9 77.2 64.5 51.8 39.1 60.6 8.3 72.3 73.0 60.3 47.6 34.8 65.1 8.4 63.3 49.1 34.8 77.7 8.9 77.3 67.3 53.1 38.8 68.3 8.6 69.9 74.1 59.8 45.6 31.4 61.1 8.4 73.4 73.7 59.5 45.2 31.0 65.7 8.5 68.5 52.8 37.0 78.4 8.9 79.7 72.4 56.6 40.9 68.9 8.6 70.9 70.9 55.1 39.4 23.6 61.6 8.4 74.4 74.4 58.7 42.9 27.2 66.3 8.5 90 32.0 48.1 64.1 57.3 43.2 54.3 65.3 58.4 62.7 54.4 60.5 66.5 59.5 63.9 65.7 66.7 67.8 60.6 65.1 73.3 68.3 61.1 65.7 78.4 68.9 61.6 66.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 25.5 18.7 39.7 31.4 23.0 52.4 44.0 35.7 27.3 57.3 57.3 46.5 38.2 30.5 20.7 44.5 34.8 25.0 58.5 48.8 39.0 29.3 58.4 58.4 51.1 41.3 62.7 56.0 46.3 36.5 35.5 22.8 49.3 38.2 27.0 64.7 53.5 42.4 31.2 59.5 59.5 55.6 44.5 63.9 61.5 50.4 39.2 40.5 24.8 54.1 41.6 29.0 67.8 58.3 45.8 33.2 60.6 60.6 60.2 47.6 65.1 65.1 54.4 41.9 59.2 45.1 31.0 68.3 63.3 49.2 35.1 61.1 61.1 53.1 39.0 65.7 65.7 52.5 38.4 64.3 48.6 33.0 68.9 68.2 52.6 37.0 61.6 61.6 46.0 30.4 66.3 66.3 50.6 35.0 65 29.8 31.6 26.8 33.3 28.0 35.0 29.3 24.9 24.3 14.8 19.4 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 60 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ102 (8.5 Ton) Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 2125 2550 2975 3400 3825 4250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 136.0 124.0 112.1 99.3 141.0 128.6 116.2 102.9 99.4 146.0 133.1 120.3 106.5 102.9 151.0 137.7 124.4 110.2 106.5 141.1 127.5 112.9 109.1 144.5 130.6 115.6 111.7 6.1 6.0 5.9 6.2 6.1 6.0 5.9 6.2 8.7 6.1 6.0 5.9 6.1 8.7 6.0 5.9 5.8 6.1 8.7 6.0 5.9 6.2 8.7 6.1 6.0 6.2 8.8 61.5 74.1 86.7 99.3 67.2 82.2 97.3 102.9 99.4 72.8 90.4 107.9 106.5 102.9 78.5 98.5 118.5 110.2 106.5 105.2 124.6 112.9 109.1 112.0 130.6 115.6 111.7 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 119.3 107.9 96.5 84.0 123.1 111.4 99.7 86.7 87.7 127.0 114.9 102.8 89.5 90.5 130.9 118.5 106.0 92.2 93.3 121.0 108.3 94.2 95.3 123.5 110.5 96.2 97.3 7.4 7.3 7.2 7.3 7.5 7.4 7.2 7.3 7.1 7.5 7.4 7.3 7.4 7.2 7.6 7.4 7.3 7.4 7.2 7.5 7.3 7.4 7.2 7.5 7.4 7.5 7.3 51.1 66.3 81.5 84.0 58.8 74.2 89.7 86.7 87.7 66.6 82.2 97.8 89.5 90.5 74.3 90.2 106.0 92.2 93.3 97.1 108.3 94.2 95.3 104.1 110.5 96.2 97.3 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 49.5 38.6 127.6 6.8 63.2 52.4 41.5 116.0 6.7 77.0 66.1 55.3 44.4 104.3 6.6 95.1 77.6 66.8 55.9 45.0 91.6 6.7 54.7 42.3 132.1 6.8 69.8 57.4 44.9 120.0 6.7 84.9 72.5 60.0 47.6 107.9 6.6 100.1 85.0 72.6 60.1 47.7 94.8 6.7 99.4 91.2 78.7 66.3 53.8 93.6 6.5 60.0 46.0 136.5 6.8 76.4 62.4 48.4 124.0 6.7 92.8 78.8 64.8 50.8 111.6 6.6 105.1 92.4 78.4 64.4 50.4 98.0 6.7 102.9 99.1 85.1 71.1 57.1 96.7 6.5 65.2 49.7 141.0 6.8 82.9 67.4 51.8 128.1 6.7 100.6 85.1 69.5 53.9 115.2 6.6 110.2 99.8 84.3 68.7 53.1 101.2 6.8 106.5 107.0 91.5 75.9 60.3 99.9 6.5 88.2 71.1 54.0 131.1 6.7 106.8 89.8 72.7 55.6 117.9 6.6 112.9 107.7 90.6 73.6 56.5 103.5 6.8 109.1 109.4 92.3 75.2 58.2 102.2 6.6 93.4 74.8 56.3 134.0 6.8 113.0 94.5 75.9 57.3 120.6 6.7 115.6 115.6 97.0 78.4 59.9 105.9 6.8 111.7 111.7 93.2 74.6 56.0 104.5 6.6 95°F 41.8 31.4 108.3 8.2 55.9 45.4 35.0 97.7 8.0 69.9 59.5 49.1 38.6 87.1 7.8 84.0 70.3 59.9 49.5 39.1 77.3 7.9 46.7 34.5 111.8 8.2 62.1 49.9 37.7 100.9 8.1 77.5 65.3 53.1 41.0 90.0 7.9 86.7 77.2 65.1 52.9 40.7 79.8 7.9 87.7 79.5 67.4 55.2 43.0 80.7 7.8 51.5 37.6 115.3 8.3 68.3 54.4 40.5 104.1 8.1 85.1 71.2 57.2 43.3 92.8 7.9 89.5 84.1 70.2 56.3 42.4 82.3 7.9 90.5 86.6 72.7 58.8 44.9 83.2 7.8 56.3 40.7 118.9 8.3 74.5 58.8 43.2 107.3 8.1 92.7 77.0 61.3 45.7 95.7 8.0 92.2 91.0 75.4 59.7 44.1 84.8 8.0 93.3 93.8 78.1 62.4 46.8 85.8 7.8 80.1 63.0 46.0 109.5 8.2 99.5 82.5 65.4 48.4 97.7 8.0 94.2 93.6 76.5 59.5 42.5 86.6 8.0 95.3 95.5 78.5 61.4 44.4 87.5 7.9 85.6 67.2 48.8 111.7 8.2 106.4 87.9 69.5 51.1 99.6 8.0 96.2 96.2 77.7 59.3 40.8 88.4 8.0 97.3 97.3 78.8 60.4 41.9 89.3 7.9 90 56.3 70.2 84.1 91.6 63.0 78.2 93.5 94.8 93.6 69.7 86.3 102.9 98.0 96.7 76.4 94.3 112.3 101.2 99.9 101.2 116.4 103.5 102.2 108.0 120.6 105.9 104.5 44.7 62.2 79.6 77.3 55.2 70.1 85.0 79.8 80.7 65.6 78.0 90.3 82.3 83.2 76.1 85.9 95.7 84.8 85.8 92.8 97.7 86.6 87.5 99.6 99.6 88.4 89.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 45.7 35.0 59.6 48.9 38.3 73.5 62.8 52.2 41.5 89.5 74.0 63.3 52.7 50.7 38.4 65.9 53.6 41.3 81.2 68.9 56.6 44.3 93.4 81.1 68.8 56.5 93.6 85.3 73.0 60.7 55.7 41.8 72.3 58.4 44.4 88.9 75.0 61.0 47.0 97.3 88.3 74.3 60.4 96.7 92.9 78.9 65.0 60.8 45.2 78.7 63.1 47.5 96.6 81.0 65.4 49.8 101.2 95.4 79.8 64.2 99.9 100.4 84.8 69.2 84.1 67.1 50.0 103.2 86.1 69.1 52.0 103.5 100.7 83.6 66.5 102.2 102.4 85.4 68.3 89.5 71.0 52.5 109.7 91.2 72.7 54.2 105.9 105.9 87.4 68.9 104.5 104.5 86.0 67.5 105°F 38.5 28.3 52.0 41.8 31.6 65.5 55.3 45.1 34.9 77.3 65.1 54.9 44.7 43.2 31.2 58.1 46.2 34.2 73.0 61.1 49.1 37.2 79.8 71.9 60.0 48.0 80.7 72.5 60.5 48.6 47.9 34.2 64.3 50.6 36.9 80.6 66.9 53.2 39.5 82.3 78.8 65.1 51.4 83.2 79.4 65.7 51.9 52.6 37.2 70.4 55.0 39.5 88.2 72.7 57.3 41.8 84.8 85.6 70.2 54.7 85.8 86.3 70.8 55.3 75.9 59.0 42.1 92.9 78.1 61.2 44.3 86.6 87.0 70.1 53.2 87.5 87.8 70.9 54.0 81.3 63.0 44.7 97.6 83.4 65.1 46.8 88.4 88.4 70.1 51.7 89.3 89.3 71.0 52.7 65 42.0 44.2 48.4 46.4 51.0 48.6 53.6 49.5 51.3 50.4 49.0 34.5 36.1 36.6 37.6 38.2 39.2 39.9 36.3 37.1 33.4 34.4 61 528150-YTG-T-0514 ZJ102 (8.5 Ton) (Continued) Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 97.3 87.5 77.8 70.6 100.5 90.4 80.3 72.9 73.6 103.6 93.2 82.8 75.2 75.9 106.8 96.1 85.3 77.5 78.3 98.0 87.0 79.0 79.8 99.9 88.8 80.6 81.4 9.0 8.7 8.5 8.4 9.0 8.8 8.5 8.4 8.4 9.1 8.8 8.6 8.5 8.4 9.1 8.9 8.6 8.5 8.4 8.9 8.7 8.6 8.5 8.9 8.7 8.6 8.5 38.3 58.0 77.8 70.6 51.5 65.9 80.3 72.9 73.6 64.7 73.7 82.8 75.2 75.9 77.9 81.6 85.3 77.5 78.3 88.4 87.0 79.0 79.8 95.2 88.8 80.6 81.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 35.1 25.1 86.3 9.7 48.0 38.1 28.1 77.4 9.4 61.0 51.1 41.1 31.1 68.4 9.1 70.6 59.8 49.8 39.8 29.9 63.9 9.0 39.7 28.0 89.1 9.8 54.1 42.4 30.7 79.9 9.5 68.6 56.9 45.1 33.4 70.6 9.2 72.9 66.6 54.9 43.1 31.4 66.0 9.0 73.6 65.4 53.7 41.9 30.2 66.6 10.4 44.3 30.8 91.9 9.8 60.2 46.7 33.2 82.4 9.5 76.2 62.7 49.2 35.7 72.8 9.2 75.2 73.4 59.9 46.4 32.9 68.0 9.0 75.9 72.1 58.6 45.1 31.6 68.7 10.4 48.9 33.7 94.7 9.9 66.3 51.1 35.8 84.9 9.6 83.8 68.5 53.2 38.0 75.0 9.3 77.5 80.2 64.9 49.7 34.4 70.1 9.1 78.3 78.8 63.5 48.2 33.0 70.7 10.5 71.7 55.0 38.2 86.5 9.6 86.3 73.7 57.0 40.3 76.4 9.3 79.0 80.4 63.7 46.9 30.2 71.4 9.1 79.8 80.1 63.4 46.6 29.9 72.1 10.5 77.0 58.8 40.7 88.1 9.7 88.8 78.9 60.7 42.5 77.9 9.4 80.6 80.6 62.4 44.2 26.0 72.8 9.2 81.4 81.4 63.2 45.0 26.9 73.5 10.6 90 39.4 53.9 68.4 63.9 52.8 61.7 70.6 66.0 66.6 66.2 69.5 72.8 68.0 68.7 79.6 77.3 75.0 70.1 70.7 84.0 76.4 71.4 72.1 88.1 77.9 72.8 73.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 29.5 21.9 44.1 34.4 24.6 56.6 46.8 37.1 27.4 63.9 54.5 44.8 35.0 36.2 24.7 50.2 38.7 27.1 64.2 52.6 41.1 29.6 66.0 61.3 49.8 38.2 66.6 58.3 46.8 35.3 42.9 27.4 56.2 42.9 29.6 71.7 58.4 45.2 31.9 68.0 68.0 54.7 41.5 68.7 64.8 51.5 38.2 49.5 30.2 62.3 47.2 32.1 75.0 64.2 49.2 34.1 70.1 70.1 59.7 44.7 70.7 70.7 56.2 41.1 67.5 50.9 34.4 76.4 69.3 52.8 36.2 71.4 71.4 57.2 40.7 72.1 72.1 55.8 39.2 72.7 54.7 36.6 77.9 74.4 56.3 38.3 72.8 72.8 54.7 36.7 73.5 73.5 55.4 37.4 65 25.3 26.7 23.8 28.2 24.9 29.6 26.1 24.1 22.7 18.6 19.3 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 62 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ120 (10 Ton) Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 2500 3000 3500 4000 4500 5000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 159.5 145.9 132.2 123.1 164.8 150.7 136.6 127.2 125.9 170.1 155.5 140.9 131.2 129.9 175.4 160.3 145.3 135.3 133.9 164.1 148.7 138.4 137.0 167.8 152.0 141.6 140.1 7.3 7.2 7.1 7.0 7.4 7.2 7.1 7.0 7.0 7.4 7.3 7.1 7.1 7.0 7.4 7.3 7.2 7.1 7.1 7.4 7.2 7.1 7.1 7.4 7.3 7.2 7.2 63.5 83.1 102.7 123.1 71.2 92.6 114.0 127.2 125.9 78.9 102.1 125.4 131.2 129.9 86.6 111.7 136.7 135.3 133.9 118.0 144.4 138.4 137.0 124.3 152.0 141.6 140.1 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 136.9 126.4 115.8 106.6 142.5 131.5 120.5 110.9 111.2 148.1 136.7 125.3 115.3 115.6 153.7 141.9 130.0 119.6 120.0 143.9 131.8 121.3 121.7 145.9 133.7 123.0 123.4 9.0 8.9 8.9 8.8 9.0 9.0 8.9 8.8 8.8 9.1 9.0 9.0 8.9 8.9 9.1 9.0 9.0 8.9 8.9 9.1 9.0 8.9 8.9 9.1 9.0 8.9 8.9 58.8 77.3 95.9 106.6 66.0 86.3 106.7 110.9 111.2 73.2 95.4 117.5 115.3 115.6 80.4 104.4 128.3 119.6 120.0 113.1 131.0 121.3 121.7 121.9 133.7 123.0 123.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 52.6 41.7 148.2 8.2 72.2 61.3 50.4 136.1 8.1 91.8 80.9 70.0 59.1 124.0 8.0 118.4 99.0 88.1 77.2 66.3 114.8 7.9 58.4 45.5 153.7 8.2 79.8 67.0 54.2 141.1 8.1 101.2 88.4 75.6 62.8 128.6 8.0 124.1 108.2 95.4 82.6 69.8 119.0 7.9 125.9 113.4 100.6 87.8 75.0 118.5 7.9 64.2 49.4 159.1 8.2 87.4 72.7 57.9 146.1 8.1 110.6 95.9 81.2 66.5 133.1 8.1 129.7 117.5 102.7 88.0 73.3 123.3 8.0 129.9 123.1 108.3 93.6 78.9 122.7 7.9 70.0 53.3 164.5 8.3 95.0 78.4 61.7 151.1 8.2 120.1 103.4 86.8 70.1 137.6 8.1 135.3 126.7 110.0 93.4 76.7 127.5 8.0 133.9 132.7 116.1 99.4 82.8 126.9 8.0 100.1 82.2 64.4 154.0 8.2 126.4 108.5 90.7 72.8 140.3 8.1 138.4 134.1 116.3 98.4 80.5 129.9 8.0 137.0 136.4 118.6 100.7 82.8 129.3 8.0 105.2 86.1 67.0 156.8 8.2 132.7 113.6 94.5 75.5 142.9 8.1 141.6 141.6 122.5 103.4 84.3 132.3 8.0 140.1 140.1 121.0 101.9 82.9 131.7 8.0 95°F 47.9 37.1 125.0 10.0 66.5 55.6 44.8 115.5 10.0 85.0 74.1 63.3 52.4 105.9 10.0 106.6 92.2 81.4 70.5 59.7 98.2 9.9 53.4 40.7 131.1 10.1 73.7 61.1 48.5 121.1 10.0 94.1 81.4 68.8 56.2 111.1 10.0 110.9 101.3 88.7 76.0 63.4 102.9 9.9 111.2 100.9 88.2 75.6 63.0 103.1 9.9 58.8 44.4 137.1 10.1 80.9 66.5 52.1 126.7 10.1 103.1 88.7 74.3 59.9 116.2 10.1 115.3 110.4 96.0 81.6 67.2 107.7 10.0 115.6 109.9 95.5 81.1 66.7 107.9 9.9 64.2 48.0 143.2 10.2 88.2 72.0 55.8 132.3 10.2 112.2 96.0 79.8 63.7 121.4 10.1 119.6 119.4 103.3 87.1 70.9 112.5 10.0 120.0 118.9 102.7 86.6 70.4 112.6 10.0 95.2 77.3 59.4 133.6 10.1 121.0 103.1 85.2 67.3 122.6 10.1 121.3 121.2 103.3 85.4 67.5 113.6 10.0 121.7 121.1 103.2 85.3 67.5 113.8 10.0 102.3 82.7 63.1 134.9 10.1 129.8 110.2 90.6 71.0 123.8 10.1 123.0 123.0 103.4 83.8 64.2 114.7 10.0 123.4 123.4 103.7 84.1 64.5 114.9 10.0 90 61.1 80.2 99.3 114.8 68.6 89.5 110.4 119.0 118.5 76.0 98.7 121.5 123.3 122.7 83.5 108.0 132.5 127.5 126.9 115.6 137.7 129.9 129.3 123.1 142.9 132.3 131.7 52.9 73.3 93.6 98.2 62.3 82.5 102.6 102.9 103.1 71.7 91.6 111.6 107.7 107.9 81.1 100.8 120.5 112.5 112.6 109.0 122.2 113.6 113.8 117.2 123.8 114.7 114.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 50.3 39.4 69.3 58.4 47.6 88.4 77.5 66.6 55.8 112.5 95.6 84.8 73.9 55.9 43.1 76.7 64.0 51.3 97.6 84.9 72.2 59.5 117.5 104.8 92.1 79.3 118.5 107.1 94.4 81.7 61.5 46.9 84.2 69.6 55.0 106.9 92.3 77.7 63.2 122.5 113.9 99.3 84.8 122.7 116.5 101.9 87.3 67.1 50.7 91.6 75.2 58.8 116.1 99.7 83.3 66.9 127.5 123.0 106.6 90.2 126.9 125.8 109.4 93.0 97.7 79.8 61.9 123.7 105.8 87.9 70.1 129.9 127.7 109.8 91.9 129.3 128.8 110.9 93.0 103.7 84.4 65.0 131.3 111.9 92.6 73.2 132.3 132.3 112.9 93.6 131.7 131.7 112.4 93.0 105°F 44.3 33.5 62.5 51.7 40.9 80.7 69.9 59.1 48.3 98.2 86.0 75.2 64.5 49.7 37.2 69.9 57.3 44.7 90.0 77.5 64.9 52.3 102.9 95.3 82.7 70.2 103.1 93.2 80.6 68.0 55.1 40.8 77.3 62.9 48.5 99.4 85.0 70.7 56.3 107.7 104.6 90.3 75.9 107.9 102.3 87.9 73.5 60.5 44.4 84.7 68.5 52.3 108.8 92.6 76.4 60.3 112.5 113.9 97.8 81.6 112.6 111.3 95.2 79.0 91.2 73.5 55.7 115.3 99.4 81.6 63.8 113.6 114.3 96.6 78.8 113.8 113.1 95.4 77.6 97.8 78.5 59.1 121.9 106.1 86.8 67.4 114.7 114.7 95.4 76.1 114.9 114.9 95.5 76.2 65 63.0 66.6 69.0 70.2 72.8 73.8 76.6 74.0 75.1 74.2 73.7 53.7 57.6 55.5 61.5 59.2 65.4 62.8 61.1 59.8 56.7 56.8 63 528150-YTG-T-0514 ZJ120 (10 Ton) (Continued) Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 113.0 104.5 96.0 89.7 119.6 110.6 101.6 94.9 94.9 126.1 116.6 107.2 100.1 100.1 132.7 122.7 112.7 105.3 105.3 123.4 113.3 105.9 105.9 124.0 113.9 106.5 106.4 11.0 11.0 11.0 11.0 11.1 11.1 11.1 11.0 11.0 11.2 11.2 11.2 11.1 11.0 11.3 11.3 11.3 11.2 11.1 11.2 11.2 11.2 11.1 11.2 11.2 11.2 11.1 47.0 69.2 91.4 89.7 58.6 78.6 98.5 94.9 94.9 70.2 87.9 105.6 100.1 100.1 81.8 97.3 112.7 105.3 105.3 104.9 113.3 105.9 105.9 112.5 113.9 106.5 106.4 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 40.7 30.0 101.1 12.1 58.5 47.8 37.1 93.6 12.1 76.3 65.6 55.0 44.3 86.1 12.1 89.7 79.8 69.1 58.4 47.7 81.3 12.1 46.1 33.6 108.1 12.1 66.1 53.5 41.0 100.1 12.2 86.0 73.5 61.0 48.5 92.1 12.2 94.9 89.3 76.8 64.3 51.8 87.0 12.2 94.9 85.5 73.0 60.5 47.9 86.7 12.0 51.5 37.2 115.1 12.2 73.6 59.3 44.9 106.6 12.3 95.7 81.4 67.0 52.7 98.1 12.3 100.1 98.9 84.6 70.2 55.9 92.6 12.3 100.1 94.6 80.3 66.0 51.6 92.3 12.1 56.9 40.8 122.2 12.3 81.1 65.0 48.8 113.1 12.4 105.4 89.2 73.1 56.9 104.1 12.4 105.3 108.4 92.3 76.1 60.0 98.2 12.4 105.3 103.7 87.6 71.5 55.3 98.0 12.2 87.3 69.6 52.0 113.1 12.3 109.7 95.6 78.0 60.4 104.1 12.3 105.9 107.5 89.8 72.2 54.6 98.2 12.3 105.9 105.1 87.5 69.9 52.2 98.0 12.2 93.4 74.3 55.2 113.1 12.3 113.9 102.0 82.9 63.8 104.1 12.3 106.5 106.5 87.4 68.3 49.2 98.2 12.3 106.4 106.4 87.3 68.3 49.2 98.0 12.1 90 44.1 65.1 86.1 81.3 57.2 74.7 92.1 87.0 86.7 70.3 84.2 98.1 92.6 92.3 83.4 93.7 104.1 98.2 98.0 100.8 104.1 98.2 98.0 107.8 104.1 98.2 98.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 37.0 26.4 54.5 43.9 33.3 72.0 61.4 50.8 40.2 81.3 74.1 63.0 52.3 42.5 30.0 62.2 49.8 37.3 82.0 69.5 57.1 44.6 87.0 83.3 70.9 58.4 86.7 77.8 65.3 52.9 47.9 33.6 69.9 55.6 41.3 92.0 77.7 63.4 49.1 92.6 92.6 78.8 64.6 92.3 87.0 72.7 58.4 53.3 37.1 77.6 61.5 45.3 102.0 85.8 69.7 53.6 98.2 98.2 86.8 70.7 98.0 96.2 80.0 63.9 83.3 65.8 48.3 104.0 91.9 74.4 56.9 98.2 98.2 83.1 65.6 98.0 97.1 79.6 62.1 89.0 70.1 51.3 104.1 97.9 79.1 60.3 98.2 98.2 79.4 60.6 98.0 98.0 79.1 60.3 65 41.7 46.0 40.4 50.3 44.1 54.5 47.8 48.1 44.6 41.7 41.5 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 64 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ150 (12.5 Ton) Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 3125 3750 4375 5000 5625 6250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 191.5 178.7 165.9 149.9 201.3 187.9 174.5 157.6 152.3 211.1 197.0 183.0 165.3 159.7 221.0 206.2 191.5 173.0 167.2 215.4 200.0 180.7 174.6 224.6 208.5 188.4 182.0 9.8 9.5 9.2 9.1 9.8 9.5 9.3 9.1 9.1 9.8 9.6 9.3 9.1 9.1 9.9 9.6 9.3 9.1 9.1 9.6 9.3 9.2 9.1 9.6 9.3 9.2 9.2 80.3 103.3 126.3 149.9 89.4 114.7 140.0 157.6 152.3 98.5 126.2 153.8 165.3 159.7 107.6 137.6 167.5 173.0 167.2 150.0 185.5 180.7 174.6 162.3 203.5 188.4 182.0 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 177.5 163.9 150.3 136.4 185.6 171.4 157.2 142.6 139.4 193.7 178.9 164.0 148.8 145.4 201.8 186.3 170.8 155.0 151.5 193.8 177.7 161.2 157.6 201.2 184.5 167.4 163.6 11.6 11.4 11.2 11.0 11.7 11.5 11.3 11.1 11.1 11.8 11.6 11.4 11.2 11.2 11.9 11.7 11.5 11.3 11.3 11.8 11.6 11.3 11.4 11.9 11.7 11.4 11.5 71.6 94.8 118.0 136.4 80.8 106.5 132.2 142.6 139.4 89.9 118.1 146.4 148.8 145.4 99.1 129.8 160.6 155.0 151.5 142.1 172.5 161.2 157.6 154.4 184.5 167.4 163.6 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 66.9 53.5 184.5 10.7 89.9 76.4 63.0 171.3 10.5 112.8 99.4 86.0 72.6 158.1 10.2 139.5 122.9 109.5 96.1 82.7 143.1 10.1 74.2 58.9 193.5 10.7 99.5 84.2 69.0 179.6 10.5 124.8 109.5 94.3 79.1 165.8 10.3 150.7 135.4 120.2 105.0 89.7 150.1 10.1 152.3 140.7 125.5 110.2 95.0 145.8 10.1 81.5 64.4 202.4 10.8 109.1 92.0 75.0 187.9 10.6 136.7 119.7 102.6 85.5 173.5 10.3 161.8 148.0 130.9 113.8 96.8 157.0 10.1 159.7 153.7 136.6 119.6 102.5 152.6 10.2 88.8 69.9 211.4 10.9 118.7 99.8 80.9 196.3 10.6 148.7 129.8 110.9 92.0 181.2 10.4 173.0 160.5 141.6 122.7 103.8 164.0 10.2 167.2 166.7 147.8 129.0 110.1 159.3 10.2 129.1 108.3 87.5 204.6 10.7 161.6 140.8 119.9 99.1 188.8 10.4 180.7 174.4 153.6 132.8 111.9 170.9 10.2 174.6 174.4 153.5 132.7 111.9 166.1 10.3 139.5 116.7 94.0 212.9 10.7 174.5 151.8 129.0 106.2 196.5 10.5 188.4 188.4 165.6 142.8 120.0 177.9 10.3 182.0 182.0 159.2 136.5 113.7 172.8 10.3 95°F 58.3 45.1 168.0 12.8 81.5 68.2 55.0 154.2 12.7 104.7 91.4 78.1 64.9 140.3 12.6 132.1 112.1 98.9 85.6 72.3 128.6 12.4 65.4 50.0 175.2 12.9 91.1 75.7 60.3 160.8 12.8 116.8 101.4 86.0 70.6 146.4 12.7 139.7 124.3 109.0 93.6 78.2 134.1 12.5 139.4 127.2 111.8 96.5 81.1 131.5 12.5 72.4 54.9 182.4 13.0 100.6 83.1 65.6 167.4 12.9 128.8 111.3 93.8 76.3 152.4 12.8 147.4 136.6 119.1 101.5 84.0 139.6 12.6 145.4 139.7 122.2 104.7 87.2 136.9 12.6 79.4 59.8 189.6 13.1 110.2 90.5 70.9 174.0 13.0 140.9 121.3 101.7 82.0 158.5 12.9 155.0 148.8 129.2 109.5 89.9 145.1 12.7 151.5 152.2 132.6 113.0 93.4 142.3 12.7 120.4 98.6 76.9 180.7 13.1 153.9 132.1 110.4 88.7 164.5 13.0 161.2 158.1 136.4 114.6 92.9 150.7 12.8 157.6 157.9 136.2 114.5 92.7 147.8 12.8 130.6 106.7 82.9 187.3 13.2 166.8 143.0 119.2 95.3 170.5 13.1 167.4 167.4 143.6 119.7 95.9 156.2 12.9 163.6 163.6 139.8 116.0 92.1 153.2 12.9 90 76.0 99.0 122.1 143.1 85.1 110.6 136.1 150.1 145.8 94.2 122.1 150.1 157.0 152.6 103.3 133.7 164.1 164.0 159.3 146.0 179.0 170.9 166.1 158.4 194.0 177.9 172.8 67.5 90.8 114.2 128.6 77.1 102.2 127.2 134.1 131.5 86.7 113.5 140.3 139.6 136.9 96.3 124.8 153.3 145.1 142.3 136.9 161.9 150.7 147.8 149.0 170.5 156.2 153.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 62.6 49.3 85.7 72.3 59.0 108.8 95.4 82.1 68.7 135.8 117.5 104.2 90.8 69.8 54.5 95.3 80.0 64.6 120.8 105.5 90.1 74.8 145.2 129.9 114.6 99.3 145.8 134.0 118.7 103.3 76.9 59.6 104.9 87.6 70.3 132.8 115.5 98.2 80.9 154.6 142.3 125.0 107.7 152.6 146.7 129.4 112.2 84.1 64.8 114.4 95.2 75.9 144.8 125.5 106.3 87.0 164.0 154.6 135.4 116.1 159.3 159.5 140.2 121.0 124.7 103.5 82.2 157.7 136.5 115.2 93.9 170.9 166.3 145.0 123.7 166.1 166.2 144.9 123.6 135.1 111.7 88.4 170.7 147.4 124.1 100.8 177.9 177.9 154.6 131.3 172.8 172.8 149.5 126.2 105°F 55.1 42.0 77.7 64.5 51.4 100.2 87.1 73.9 60.8 126.4 106.8 93.6 80.5 61.9 46.7 86.9 71.7 56.5 112.0 96.8 81.6 66.4 132.7 118.7 103.5 88.2 131.5 118.9 103.7 88.5 68.6 51.3 96.2 78.9 61.6 123.8 106.5 89.2 71.9 138.9 130.6 113.3 96.0 136.9 130.9 113.6 96.3 75.4 56.0 105.5 86.1 66.8 135.6 116.2 96.9 77.5 145.1 142.5 123.2 103.8 142.3 142.8 123.4 104.1 115.4 94.0 72.5 148.3 126.8 105.3 83.9 150.7 149.3 127.9 106.4 147.8 148.0 126.5 105.0 125.4 101.8 78.2 161.0 137.4 113.8 90.2 156.2 156.2 132.6 109.0 153.2 153.2 129.6 106.0 65 77.5 83.9 88.0 90.4 94.9 96.9 101.7 102.4 102.3 108.0 102.9 67.3 73.0 73.3 78.7 79.0 84.5 84.7 84.9 83.6 85.4 82.4 65 528150-YTG-T-0514 ZJ150 (12.5 Ton) (Continued) Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 158.4 144.4 130.4 120.7 164.8 150.2 135.6 125.6 123.7 171.1 156.0 140.8 130.4 128.4 177.5 161.8 146.1 135.3 133.2 167.6 151.3 140.1 138.0 173.4 156.5 145.0 142.7 14.0 14.0 14.0 13.8 14.1 14.1 14.1 13.9 13.9 14.2 14.2 14.2 14.0 14.0 14.4 14.3 14.3 14.1 14.1 14.4 14.4 14.2 14.2 14.5 14.5 14.3 14.3 63.3 86.9 110.4 120.7 73.4 97.9 122.3 125.6 123.7 83.5 108.8 134.2 130.4 128.4 93.6 119.8 146.1 135.3 133.2 131.7 151.3 140.1 138.0 143.6 156.5 145.0 142.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 51.9 38.9 148.8 15.3 73.8 60.8 47.8 134.6 15.3 95.8 82.7 69.7 56.7 120.4 15.4 120.7 101.4 88.4 75.3 62.3 112.9 15.2 58.4 43.3 154.3 15.4 82.8 67.8 52.7 139.6 15.4 107.3 92.2 77.2 62.1 124.8 15.5 125.6 113.0 98.0 82.9 67.9 117.1 15.3 123.7 110.6 95.6 80.5 65.5 115.8 15.3 64.8 47.8 159.8 15.5 91.8 74.7 57.7 144.5 15.5 118.7 101.7 84.6 67.6 129.2 15.6 130.4 124.6 107.6 90.5 73.4 121.2 15.4 128.4 122.0 104.9 87.9 70.8 119.9 15.5 71.3 52.2 165.3 15.6 100.8 81.7 62.6 149.5 15.7 130.2 111.2 92.1 73.0 133.7 15.7 135.3 136.2 117.2 98.1 79.0 125.4 15.5 133.2 133.3 114.3 95.2 76.1 124.1 15.6 110.5 89.3 68.1 154.5 15.8 142.7 121.5 100.3 79.0 138.1 15.8 140.1 140.6 119.4 98.1 76.9 129.6 15.6 138.0 138.0 116.8 95.6 74.4 128.2 15.7 120.2 96.9 73.5 159.4 15.9 155.2 131.8 108.4 85.0 142.5 15.9 145.0 145.0 121.6 98.2 74.8 133.7 15.7 142.7 142.7 119.4 96.0 72.6 132.3 15.8 90 56.6 82.9 106.6 112.9 69.8 93.6 117.4 117.1 115.8 82.9 104.2 128.1 121.2 119.9 96.0 114.8 133.7 125.4 124.1 126.5 138.1 129.6 128.2 138.2 142.5 133.7 132.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 48.7 35.8 70.0 57.1 44.2 91.3 78.4 65.5 52.6 112.9 96.0 83.1 70.2 54.9 40.0 78.7 63.8 48.9 102.5 87.6 72.7 57.9 117.1 107.3 92.5 77.6 115.8 102.3 87.4 72.5 61.1 44.2 87.4 70.5 53.7 113.7 96.9 80.0 63.2 121.2 118.6 101.8 85.0 119.9 113.1 96.3 79.4 67.2 48.5 96.1 77.3 58.5 124.9 106.1 87.3 68.5 125.4 125.4 111.1 92.4 124.1 123.9 105.1 86.3 105.6 84.6 63.6 137.1 116.1 95.2 74.2 129.6 129.6 110.9 89.9 128.2 128.1 107.1 86.1 115.1 91.9 68.8 142.5 126.2 103.0 79.9 133.7 133.7 110.6 87.4 132.3 132.3 109.1 86.0 65 57.3 62.7 57.7 68.1 62.6 73.6 67.5 68.9 65.2 64.3 62.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 66 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037-150 Cooling and Reheat Capacities ZR037 (3.0 Ton) Cooling Air on Evaporator Coil CFM 750 900 1050 1200 1350 1500 750 900 1050 1200 1350 1500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 48.2 43.9 39.6 35.5 50.4 45.9 41.4 37.1 33.3 52.7 47.9 43.2 38.7 34.7 54.9 50.0 45.1 40.4 36.2 50.0 45.0 40.4 36.2 49.9 45.0 40.3 36.2 0.2 0.8 1.3 1.1 0.5 1.1 1.6 1.4 1.3 0.8 1.3 1.9 1.7 1.6 1.0 1.6 2.2 2.0 1.8 1.4 2.0 1.8 1.6 1.2 1.8 1.6 1.5 20.1 24.6 29.0 35.5 22.1 27.8 33.4 37.1 33.3 24.1 31.0 37.8 38.7 34.7 26.1 34.2 42.2 40.4 36.2 36.8 43.6 40.4 36.2 39.3 45.0 40.3 36.2 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 38.8 35.6 32.5 27.3 40.5 37.2 33.9 28.5 26.2 42.2 38.7 35.3 29.7 27.2 43.9 40.3 36.7 30.8 28.3 40.1 36.5 30.7 28.2 40.0 36.4 30.6 28.1 3.1 2.8 2.6 2.7 3.0 2.7 2.5 2.7 2.4 2.8 2.6 2.4 2.6 2.3 2.7 2.5 2.3 2.5 2.2 2.5 2.3 2.5 2.2 2.5 2.3 2.5 2.2 13.9 19.9 25.9 27.3 17.2 23.4 29.5 28.5 26.2 20.6 26.8 33.1 29.7 27.2 23.9 30.3 36.7 30.8 28.3 32.4 36.5 30.7 28.2 34.4 36.4 30.6 28.1 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 16.2 13.0 43.5 1.6 21.3 18.1 14.9 39.8 1.8 26.5 23.3 20.1 16.8 36.0 2.0 32.6 28.4 25.1 21.9 18.7 31.4 1.9 18.2 14.3 45.5 1.7 23.9 20.0 16.1 41.6 1.9 29.5 25.6 21.7 17.8 37.6 2.1 35.2 31.3 27.4 23.5 19.6 32.8 2.0 33.4 30.5 26.6 22.7 18.8 29.7 1.9 20.3 15.7 47.4 1.8 26.4 21.8 17.2 43.3 2.0 32.5 27.9 23.4 18.8 39.2 2.1 37.8 34.2 29.6 25.0 20.5 34.2 2.1 34.8 33.3 28.8 24.2 19.6 31.0 1.9 22.3 17.0 49.4 1.9 28.9 23.6 18.4 45.1 2.1 35.5 30.3 25.0 19.8 40.9 2.2 40.4 37.1 31.8 26.6 21.3 35.6 2.2 36.2 36.2 30.9 25.7 20.4 32.3 2.0 31.0 25.2 19.5 45.0 2.0 38.2 32.3 26.6 20.8 40.8 2.1 40.4 38.7 33.0 27.2 21.5 35.5 2.1 36.2 36.2 30.4 24.7 18.9 32.2 1.9 33.1 26.8 20.6 45.0 1.9 40.9 34.4 28.2 21.9 40.7 2.1 40.3 40.3 34.1 27.8 21.6 35.5 2.0 36.2 36.2 29.9 23.7 17.4 32.1 1.9 95°F 11.6 8.5 36.4 2.7 16.9 13.8 10.8 32.8 2.7 22.2 19.1 16.1 13.0 29.2 2.6 26.6 21.0 18.0 14.9 11.9 25.0 2.6 13.5 9.8 37.5 2.7 19.7 16.0 12.3 33.8 2.7 25.8 22.1 18.4 14.7 30.1 2.6 28.0 24.3 20.6 16.9 13.2 25.8 2.6 26.0 22.3 18.6 14.9 11.2 24.9 2.4 15.5 11.2 38.6 2.7 22.5 18.1 13.8 34.8 2.7 29.4 25.1 20.7 16.4 31.0 2.6 29.4 27.6 23.2 18.9 14.5 26.5 2.6 27.2 25.3 21.0 16.6 12.3 25.6 2.5 17.5 12.5 39.7 2.7 25.3 20.3 15.3 35.8 2.7 33.1 28.1 23.1 18.1 31.9 2.6 30.8 30.8 25.8 20.8 15.8 27.3 2.6 28.3 28.3 23.3 18.3 13.3 26.4 2.5 26.7 21.1 15.5 35.8 2.6 34.7 29.2 23.6 17.9 31.9 2.6 30.7 30.7 25.1 19.5 13.8 27.3 2.5 28.2 28.2 22.6 17.0 11.3 26.4 2.4 28.2 21.9 15.6 35.8 2.6 36.4 30.3 24.1 17.8 31.9 2.5 30.6 30.6 24.3 18.1 11.8 27.3 2.5 28.1 28.1 21.8 15.6 9.3 26.4 2.4 90 17.0 22.2 27.5 31.4 19.7 25.6 31.5 32.8 29.7 22.3 28.9 35.4 34.2 31.0 25.0 32.2 39.4 35.6 32.3 34.6 40.1 35.5 32.2 36.9 40.7 35.5 32.1 12.7 19.0 25.3 25.0 16.5 22.0 27.5 25.8 24.9 20.4 25.0 29.7 26.5 25.6 24.2 28.0 31.9 27.3 26.4 30.4 31.9 27.3 26.4 32.7 31.9 27.3 26.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 13.9 10.7 19.1 16.0 12.8 24.3 21.2 18.1 14.9 29.6 24.7 21.6 18.4 15.9 12.1 21.8 18.0 14.2 27.7 23.9 20.1 16.3 31.6 27.8 24.0 20.2 29.7 26.4 22.6 18.8 17.9 13.4 24.4 20.0 15.5 31.0 26.5 22.1 17.6 33.6 30.9 26.4 21.9 31.0 29.3 24.9 20.4 19.9 14.8 27.1 22.0 16.8 34.3 29.2 24.0 18.9 35.6 34.0 28.8 23.7 32.3 32.3 27.1 22.0 28.9 23.2 17.5 36.5 30.8 25.1 19.4 35.5 34.7 29.0 23.3 32.2 32.2 26.5 20.8 30.6 24.4 18.1 38.6 32.4 26.1 19.9 35.5 35.5 29.2 23.0 32.1 32.1 25.9 19.6 105°F 11.2 8.3 16.1 13.1 10.2 20.9 17.9 15.0 12.1 24.7 19.5 16.5 13.6 13.0 9.4 18.4 14.9 11.3 23.9 20.3 16.8 13.2 25.5 22.1 18.5 14.9 24.9 21.4 17.8 14.2 14.7 10.5 20.8 16.6 12.4 26.9 22.7 18.5 14.3 26.4 24.7 20.5 16.3 25.6 23.9 19.6 15.4 16.4 11.6 23.2 18.4 13.5 30.0 25.1 20.3 15.4 27.3 27.3 22.5 17.6 26.4 26.4 21.5 16.7 24.9 19.5 14.0 30.9 26.7 21.2 15.7 27.3 27.3 21.9 16.4 26.4 26.4 20.9 15.5 26.7 20.6 14.5 31.9 28.2 22.1 16.0 27.3 27.3 21.2 15.2 26.4 26.4 20.3 14.2 65 15.3 16.4 15.0 17.5 15.9 18.6 16.9 17.6 15.1 16.7 13.4 10.7 11.4 10.6 12.1 11.2 12.8 11.8 10.9 10.0 9.1 8.2 67 528150-YTG-T-0514 ZR037 (3.0 Ton) Cooling (Continued) Air on Evaporator Coil CFM 750 900 1050 1200 1350 1500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 34.0 30.0 26.0 22.8 34.5 30.4 26.4 23.1 23.7 35.0 30.9 26.8 23.4 24.0 35.4 31.3 27.2 23.8 24.4 31.5 27.3 23.9 24.5 31.6 27.4 24.0 24.6 2.4 2.5 2.6 2.4 2.5 2.6 2.7 2.5 2.5 2.6 2.7 2.8 2.6 2.6 2.7 2.8 2.9 2.7 2.7 2.7 2.9 2.6 2.6 2.7 2.8 2.5 2.5 11.6 18.1 24.6 22.8 15.9 20.7 25.5 23.1 23.7 20.1 23.2 26.3 23.4 24.0 24.4 25.8 27.2 23.8 24.4 28.4 27.3 23.9 24.5 31.1 27.4 24.0 24.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 10.9 8.1 31.5 2.1 15.3 12.4 9.6 27.2 2.3 19.6 16.8 13.9 11.1 22.8 2.6 22.8 18.0 15.1 12.3 9.5 20.5 2.2 12.4 9.0 31.4 2.3 17.2 13.8 10.3 27.1 2.5 22.0 18.6 15.1 11.7 22.7 2.8 23.1 19.9 16.5 13.0 9.6 20.4 2.4 23.7 20.4 17.0 13.5 10.1 22.5 2.5 13.9 9.8 31.3 2.5 19.2 15.1 11.0 26.9 2.8 24.4 20.4 16.3 12.2 22.6 3.0 23.4 21.8 17.8 13.7 9.6 20.3 2.6 24.0 22.4 18.3 14.3 10.2 22.5 2.7 15.4 10.7 31.2 2.7 21.1 16.4 11.8 26.8 3.0 26.9 22.2 17.5 12.8 22.4 3.3 23.8 23.8 19.1 14.4 9.7 20.2 2.8 24.4 24.4 19.7 15.0 10.3 22.4 2.9 23.1 17.9 12.6 27.1 2.9 27.1 24.1 18.8 13.6 22.7 3.1 23.9 23.9 18.6 13.3 8.1 20.5 2.7 24.5 24.5 19.2 14.0 8.7 22.7 2.8 25.2 19.3 13.4 27.4 2.7 27.4 26.0 20.2 14.3 23.0 3.0 24.0 24.0 18.1 12.3 6.4 20.7 2.6 24.6 24.6 18.8 12.9 7.0 22.9 2.7 90 11.5 17.2 22.8 20.5 15.9 19.3 22.7 20.4 22.5 20.3 21.4 22.6 20.3 22.5 24.7 23.6 22.4 20.2 22.4 26.5 22.7 20.5 22.7 27.4 23.0 20.7 22.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 9.9 7.9 14.5 11.7 9.0 18.3 15.6 12.9 10.1 20.5 16.5 13.7 11.0 11.8 8.5 16.0 12.7 9.3 20.1 16.8 13.5 10.2 20.4 17.7 14.4 11.1 22.5 19.5 16.2 12.8 13.7 9.2 17.5 13.6 9.7 21.9 18.0 14.1 10.2 20.3 19.0 15.0 11.1 22.5 21.0 17.0 13.1 15.6 9.8 19.0 14.5 10.0 22.4 19.2 14.7 10.2 20.2 20.2 15.7 11.2 22.4 22.4 17.9 13.4 21.4 16.3 11.2 22.7 21.6 16.5 11.4 20.5 20.5 15.4 10.3 22.7 22.7 17.6 12.5 23.7 18.0 12.3 23.0 23.0 18.2 12.6 20.7 20.7 15.0 9.3 22.9 22.9 17.2 11.5 65 8.3 7.7 9.5 7.2 9.2 6.7 8.9 5.2 7.4 3.7 5.9 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 68 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037 (3.0 Ton) Reheat Air on Evaporator Coil CFM Total Capacity1 (MBh) Total Input (kW)2 62.5 64 65.3 62.5 64 65.3 62.5 64 65.3 14.1 15.3 17.0 14.9 15.6 16.1 21.7 22.3 22.5 1.3 1.3 1.4 1.3 1.3 1.3 1.9 1.9 1.8 62.5 64 65.3 62.5 64 65.3 62.5 64 62 18.5 19.7 20.9 19.2 20.3 22.2 19.8 21.1 22.3 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 62.5 64 65.3 62.5 64 65.3 62.5 64 65.3 16.3 17.6 18.8 16.6 18.0 18.9 15.8 17.3 18.5 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 62.5 64 65.3 62.5 64 65.3 62.5 64 62 12.0 12.5 13.4 11.8 12.9 13.9 11.7 12.6 13.6 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 WB (°F) Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total (- indicates heating) Capacity1 Return Dry Bulb (°F) (MBh) 75 40 °F 1050 1200 1350 50 °F 8.9 8.1 7.1 9.7 8.7 7.8 11.1 9.3 8.0 19.7 21.3 22.5 20.3 21.2 23.1 21.6 23.1 24.7 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 8.1 6.6 5.4 9.0 7.6 6.3 9.8 8.4 7.2 17.0 18.4 19.6 17.0 18.5 19.9 16.1 17.3 18.8 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 7.2 5.5 4.0 7.4 6.1 5.0 7.8 6.7 5.2 15.0 16.2 16.6 14.9 16.1 17.2 14.4 15.6 16.7 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 4.5 3.1 1.9 5.0 3.7 2.3 5.6 4.0 2.7 7.5 8.5 9.3 8.8 8.0 8.2 6.0 6.7 7.7 2.3 2.3 2.4 2.3 2.3 2.4 2.3 2.3 2.3 60 °F 1050 1200 1350 1200 1350 1200 1350 6.8 5.5 4.4 7.9 6.6 5.5 8.4 6.8 5.7 80 °F 85 °F 1050 8.9 7.5 6.2 9.8 8.3 7.1 10.9 9.7 8.2 70 °F 75 °F 1050 Sensible Capacity (MBh) (- indicates heating) Return Dry Bulb (°F) 75 Total Input (kW)2 5.9 4.5 3.6 6.7 5.5 3.9 7.1 5.8 4.4 95 °F 1.7 0.5 -0.9 -0.6 0.6 -0.9 1.9 0.6 -0.7 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 69 528150-YTG-T-0514 ZR049 (4.0 Ton) Cooling Air on Evaporator Coil CFM 1000 1200 1400 1600 1800 2000 1000 1200 1400 1600 1800 2000 70 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 70.8 62.1 53.5 48.3 73.1 64.2 55.3 50.0 48.7 75.5 66.3 57.1 51.6 50.2 77.9 68.4 58.9 53.2 51.8 70.3 60.5 54.7 53.2 72.1 62.1 56.1 54.7 1.6 2.0 2.4 2.0 1.8 2.2 2.6 2.2 2.2 2.1 2.4 2.8 2.4 2.4 2.3 2.6 3.0 2.6 2.6 2.4 2.8 2.4 2.4 2.2 2.6 2.2 2.2 27.3 34.1 40.8 48.3 30.4 37.7 45.1 50.0 48.7 33.4 41.4 49.4 51.6 50.2 36.5 45.1 53.7 53.2 51.8 48.1 57.9 54.7 53.2 51.0 62.1 56.1 54.7 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 52.2 47.9 43.6 37.9 54.4 49.9 45.4 39.5 39.6 56.6 51.9 47.3 41.1 41.2 58.8 54.0 49.1 42.7 42.8 54.1 49.2 42.7 42.8 54.2 49.3 42.8 42.9 4.4 3.9 3.4 3.9 4.2 3.7 3.2 3.6 3.6 4.0 3.5 3.0 3.4 3.4 3.7 3.3 2.9 3.2 3.2 3.5 3.1 3.4 3.4 3.7 3.3 3.7 3.7 24.8 30.5 36.3 37.9 27.7 33.9 40.1 39.5 39.6 30.5 37.3 44.0 41.1 41.2 33.4 40.7 47.9 42.7 42.8 44.1 48.6 42.7 42.8 47.5 49.3 42.8 42.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 22.8 18.2 61.5 3.0 29.5 24.9 20.3 55.0 3.0 36.2 31.6 27.0 22.4 48.5 2.9 46.8 37.7 33.1 28.5 23.9 43.1 2.9 25.1 19.9 63.8 3.0 32.5 27.3 22.0 57.1 3.0 39.9 34.6 29.4 24.2 50.3 2.9 48.9 41.3 36.1 30.9 25.6 44.7 2.9 48.7 44.1 38.9 33.7 28.4 44.1 2.9 27.5 21.6 66.1 3.0 35.5 29.6 23.8 59.1 3.0 43.5 37.6 31.8 25.9 52.2 2.9 51.1 44.9 39.0 33.1 27.3 46.3 2.9 50.2 48.0 42.1 36.2 30.3 45.7 2.9 29.9 23.4 68.4 3.0 38.6 32.0 25.5 61.2 3.0 47.2 40.7 34.1 27.6 54.0 2.9 53.2 48.5 42.0 35.4 28.9 47.9 2.9 51.8 51.8 45.3 38.7 32.2 47.3 2.9 40.9 33.7 26.6 62.2 3.0 50.0 42.8 35.7 28.5 54.8 2.9 54.7 52.3 45.1 38.0 30.8 48.7 2.9 53.2 53.2 46.1 38.9 31.7 48.0 2.9 43.2 35.4 27.7 63.1 3.0 52.8 45.0 37.2 29.4 55.7 2.9 56.1 56.1 48.3 40.5 32.7 49.5 2.9 54.7 54.7 46.9 39.1 31.3 48.8 2.9 95°F 20.5 16.1 51.3 4.2 26.2 21.9 17.6 45.4 3.9 31.9 27.6 23.3 19.0 39.6 3.6 37.9 33.9 29.5 25.2 20.9 34.1 3.8 22.6 17.5 52.8 4.1 28.8 23.8 18.7 46.8 3.8 35.1 30.0 25.0 19.9 40.8 3.5 39.5 36.8 31.7 26.7 21.6 35.1 3.7 39.6 36.9 31.8 26.8 21.7 35.7 3.7 24.7 18.9 54.3 4.0 31.5 25.7 19.9 48.2 3.7 38.2 32.4 26.6 20.8 42.0 3.4 41.1 39.7 33.9 28.1 22.3 36.2 3.6 41.2 39.8 34.0 28.2 22.4 36.8 3.6 26.9 20.3 55.8 3.9 34.1 27.6 21.0 49.5 3.6 41.3 34.8 28.3 21.7 43.2 3.4 42.7 42.7 36.1 29.6 23.1 37.2 3.5 42.8 42.8 36.2 29.7 23.1 37.9 3.5 36.9 29.7 22.5 49.9 3.7 44.7 37.5 30.3 23.1 43.5 3.5 42.7 42.7 35.5 28.4 21.2 37.5 3.6 42.8 42.8 35.6 28.4 21.3 38.1 3.6 39.7 31.8 24.0 50.3 3.9 48.0 40.2 32.3 24.5 43.8 3.6 42.8 42.8 35.0 27.1 19.3 37.8 3.7 42.9 42.9 35.1 27.2 19.4 38.4 3.7 90 26.1 32.3 38.5 43.1 29.0 35.8 42.6 44.7 44.1 32.0 39.3 46.7 46.3 45.7 34.9 42.9 50.8 47.9 47.3 46.1 53.3 48.7 48.0 49.3 55.7 49.5 48.8 21.3 28.4 35.5 34.1 25.3 31.6 37.8 35.1 35.7 29.4 34.8 40.2 36.2 36.8 33.5 38.0 42.6 37.2 37.9 41.5 43.2 37.5 38.1 44.9 43.8 37.8 38.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 21.6 17.2 27.8 23.4 18.9 34.1 29.6 25.2 20.7 42.3 35.8 31.3 26.9 23.9 18.7 30.7 25.5 20.4 37.5 32.3 27.2 22.0 44.2 39.1 33.9 28.8 44.1 40.5 35.4 30.2 26.1 20.3 33.5 27.7 21.8 40.9 35.0 29.2 23.3 46.1 42.3 36.5 30.6 45.7 43.9 38.1 32.2 28.4 21.9 36.3 29.8 23.3 44.3 37.7 31.2 24.7 47.9 45.6 39.1 32.5 47.3 47.3 40.7 34.2 38.9 31.7 24.5 47.3 40.2 33.0 25.8 48.7 47.5 40.3 33.2 48.0 48.0 40.9 33.7 41.5 33.6 25.8 50.4 42.6 34.8 27.0 49.5 49.5 41.6 33.8 48.8 48.8 41.0 33.1 105°F 18.4 14.1 24.1 19.9 15.6 29.8 25.6 21.3 17.1 34.1 29.2 25.0 20.7 20.4 15.4 26.6 21.7 16.7 32.9 27.9 22.9 18.0 35.1 31.9 26.9 22.0 35.7 32.4 27.5 22.5 22.4 16.7 29.1 23.5 17.8 35.9 30.2 24.6 18.9 36.2 34.6 28.9 23.2 36.8 35.1 29.5 23.8 24.4 18.0 31.7 25.3 18.9 39.0 32.6 26.2 19.8 37.2 37.2 30.8 24.5 37.9 37.9 31.5 25.1 34.4 27.3 20.3 41.1 35.2 28.1 21.1 37.5 37.5 30.4 23.4 38.1 38.1 31.1 24.0 37.1 29.4 21.6 43.2 37.9 30.1 22.4 37.8 37.8 30.0 22.3 38.4 38.4 30.7 22.9 65 22.4 23.6 25.1 24.8 26.4 26.0 27.7 26.0 26.5 26.0 25.3 16.5 17.0 17.6 17.5 18.1 18.1 18.7 16.3 16.9 14.5 15.2 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR049 (4.0 Ton) Cooling (Continued) Air on Evaporator Coil CFM 1000 1200 1400 1600 1800 2000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 50.4 43.0 35.6 30.3 51.2 43.7 36.1 30.8 31.9 52.0 44.4 36.7 31.3 32.4 52.9 45.1 37.3 31.8 32.9 45.7 37.8 32.2 33.5 46.4 38.4 32.7 34.0 4.0 3.9 3.8 3.7 4.0 3.9 3.8 3.7 3.8 4.0 3.9 3.8 3.7 3.8 4.0 3.9 3.8 3.8 3.8 3.9 3.9 3.8 3.8 4.0 3.9 3.8 3.8 17.7 26.2 34.6 30.3 23.0 29.3 35.5 30.8 31.9 28.3 32.3 36.4 31.3 32.4 33.6 35.4 37.3 31.8 32.9 38.8 37.8 32.2 33.5 42.2 38.4 32.7 34.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 16.3 12.1 49.5 3.7 22.0 17.8 13.6 40.5 3.9 27.7 23.5 19.3 15.2 31.5 4.0 30.3 24.6 20.5 16.3 12.1 26.5 3.6 18.1 13.3 49.6 3.9 24.4 19.5 14.7 40.6 4.0 30.7 25.8 20.9 16.1 31.5 4.1 30.8 27.0 22.1 17.3 12.4 26.5 3.8 31.9 28.0 23.2 18.3 13.4 28.1 3.8 20.0 14.5 49.7 4.0 26.8 21.3 15.7 40.6 4.1 33.6 28.1 22.5 17.0 31.4 4.2 31.3 29.4 23.8 18.3 12.8 26.4 3.9 32.4 30.5 24.9 19.4 13.8 28.1 3.9 21.9 15.6 49.9 4.2 29.2 23.0 16.8 40.6 4.3 36.6 30.3 24.1 17.9 31.3 4.3 31.8 31.8 25.5 19.3 13.1 26.3 4.0 32.9 32.9 26.7 20.5 14.3 28.0 4.1 31.9 24.9 18.0 41.6 4.2 37.5 32.9 26.0 19.0 32.2 4.3 32.2 32.2 25.3 18.4 11.4 27.0 3.9 33.5 33.5 26.5 19.6 12.6 28.8 4.0 34.6 26.9 19.3 42.6 4.1 38.4 35.5 27.9 20.2 33.0 4.2 32.7 32.7 25.1 17.4 9.8 27.7 3.8 34.0 34.0 26.3 18.6 11.0 29.5 3.9 90 16.5 24.0 31.5 26.5 22.4 26.9 31.5 26.5 28.1 28.4 29.9 31.4 26.4 28.1 34.3 32.8 31.3 26.3 28.0 36.2 32.2 27.0 28.8 39.5 33.0 27.7 29.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 12.8 10.1 19.9 15.8 11.7 25.6 21.5 17.4 13.3 26.5 20.0 15.9 11.8 15.9 11.2 22.2 17.4 12.7 28.4 23.7 18.9 14.2 26.5 22.1 17.4 12.6 28.1 23.6 18.8 14.1 19.0 12.2 24.5 19.0 13.6 31.3 25.9 20.5 15.1 26.4 24.2 18.8 13.4 28.1 25.8 20.4 15.0 22.2 13.3 26.8 20.7 14.6 31.3 28.1 22.0 15.9 26.3 26.3 20.2 14.2 28.0 28.0 22.0 15.9 29.4 22.6 15.7 32.2 30.6 23.8 17.0 27.0 27.0 20.2 13.4 28.8 28.8 21.9 15.1 32.0 24.4 16.9 33.0 33.0 25.6 18.1 27.7 27.7 20.1 12.6 29.5 29.5 21.9 14.4 65 7.7 7.8 9.3 8.0 9.6 8.1 9.8 6.6 8.3 5.0 6.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 71 528150-YTG-T-0514 ZR049 (4.0 Ton) Reheat Air on Evaporator Coil CFM Total Capacity1 (MBh) Total Input (kW)2 62.5 64 65.3 62.5 64 65.3 62.5 64 65.3 24.5 25.7 26.6 24.0 25.8 27.1 24.3 26.2 27.1 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 62.5 64 65.3 62.5 64 65.3 62.5 64 62 21.8 25.3 26.9 22.7 25.4 26.9 20.1 22.3 23.7 2.6 2.7 2.7 2.7 2.7 2.7 2.6 2.6 2.6 62.5 64 65.3 62.5 64 65.3 62.5 64 65.3 19.0 21.5 22.2 19.3 21.3 22.6 16.9 18.2 19.9 2.7 2.8 2.8 2.8 2.8 2.8 2.7 2.7 2.8 62.5 64 65.3 62.5 64 65.3 62.5 64 62 17.7 19.0 20.4 16.2 18.2 19.6 13.3 14.8 15.8 2.9 2.9 2.9 2.9 3.0 3.0 2.9 2.9 2.9 WB (°F) Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total (- indicates heating) Capacity1 Return Dry Bulb (°F) (MBh) 75 40 °F 1200 1600 2000 50 °F 9.1 7.4 6.1 12.4 10.0 8.3 12.9 11.1 9.2 22.9 26.9 27.1 24.5 26.7 28.5 22.7 24.7 26.5 2.6 2.7 2.6 2.6 2.6 2.6 2.6 2.6 2.6 7.1 6.3 4.8 9.9 8.8 7.5 10.2 8.6 6.9 19.8 23.0 23.5 20.6 22.4 24.4 18.2 20.5 21.4 2.7 2.8 2.7 2.7 2.8 2.8 2.7 2.7 2.7 5.5 5.1 2.8 8.1 6.3 4.7 7.9 6.3 4.8 17.6 20.9 21.5 17.9 19.9 21.1 15.1 16.7 18.3 2.8 2.9 2.9 2.9 2.9 2.9 2.8 2.8 2.8 5.0 3.4 2.1 6.4 5.0 3.1 6.6 4.7 3.1 12.8 13.8 14.0 9.7 10.8 12.2 6.2 7.2 8.0 3.1 3.2 3.1 3.1 3.2 3.2 3.0 3.0 3.0 60 °F 1200 1600 2000 1600 2000 1600 2000 6.2 0.0 2.9 8.8 6.8 5.9 8.9 7.7 5.3 80 °F 85 °F 1200 8.0 7.2 5.5 11.2 9.2 7.7 11.6 10.0 8.5 70 °F 75 °F 1200 Sensible Capacity (MBh) (- indicates heating) Return Dry Bulb (°F) 75 Total Input (kW)2 4.7 3.7 2.3 7.5 5.7 4.1 7.1 5.6 4.0 95 °F 3.5 -0.2 -1.5 2.4 1.0 -0.7 1.4 -0.1 -1.5 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 72 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR061 (5.0 Ton) Cooling Air on Evaporator Coil CFM 1250 1500 1750 2000 2250 2500 1250 1500 1750 2000 2250 2500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 81.7 72.8 64.0 57.0 85.0 75.8 66.6 59.3 58.1 88.3 78.7 69.2 61.6 60.4 91.6 81.7 71.8 63.9 62.6 82.5 72.5 64.5 63.3 83.4 73.2 65.2 63.9 5.9 5.0 4.0 3.6 5.4 4.5 3.6 3.2 4.1 4.9 4.1 3.2 2.8 3.7 4.4 3.6 2.8 2.5 3.2 3.9 3.0 2.6 3.5 4.2 3.3 2.8 3.7 33.6 41.9 50.2 57.0 37.9 47.1 56.4 59.3 58.1 42.1 52.3 62.5 61.6 60.4 46.3 57.5 68.6 63.9 62.6 60.8 70.9 64.5 63.3 64.2 73.2 65.2 63.9 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 70.7 62.8 54.8 48.1 73.1 64.9 56.7 49.7 49.7 75.5 67.0 58.5 51.3 51.3 77.9 69.1 60.4 52.9 52.9 69.3 60.5 53.0 53.1 69.4 60.7 53.2 53.2 3.7 3.7 3.7 4.0 3.8 3.7 3.7 4.0 4.0 3.8 3.7 3.7 4.0 4.0 3.8 3.8 3.7 4.0 4.1 3.9 3.9 4.3 4.3 4.1 4.1 4.5 4.5 30.8 38.2 45.5 48.1 34.5 42.5 50.5 49.7 49.7 38.2 46.8 55.4 51.3 51.3 41.8 51.1 60.4 52.9 52.9 55.0 60.5 53.0 53.1 58.9 60.7 53.2 53.2 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 27.7 21.9 76.2 4.8 36.1 30.2 24.3 67.8 4.3 44.4 38.5 32.6 26.7 59.4 3.8 57.0 45.7 39.9 33.9 28.1 52.5 3.8 31.1 24.3 79.0 4.6 40.4 33.6 26.8 70.3 4.1 49.6 42.9 36.1 29.3 61.6 3.7 59.3 50.9 44.1 37.4 30.6 54.5 3.6 58.1 52.1 45.3 38.6 31.8 53.9 4.1 34.4 26.8 81.9 4.3 44.6 37.0 29.4 72.9 3.9 54.8 47.2 39.5 31.9 63.9 3.5 61.6 56.0 48.4 40.7 33.1 56.4 3.4 60.4 57.3 49.7 42.1 34.4 55.8 3.9 37.8 29.3 84.7 4.1 48.9 40.4 31.9 75.4 3.7 60.1 51.5 43.0 34.5 66.1 3.3 63.9 61.2 52.7 44.1 35.6 58.4 3.2 62.6 62.6 54.1 45.6 37.0 57.8 3.6 51.6 42.4 33.2 75.9 3.9 63.3 54.1 44.9 35.8 66.5 3.5 64.5 63.2 54.0 44.8 35.6 58.8 3.5 63.3 63.3 54.1 44.9 35.7 58.2 3.9 54.3 44.5 34.6 76.4 4.1 66.6 56.7 46.9 37.1 66.9 3.7 65.2 65.2 55.3 45.5 35.6 59.2 3.7 63.9 63.9 54.0 44.2 34.4 58.5 4.1 95°F 25.3 19.7 65.8 4.9 32.6 27.0 21.5 57.8 4.6 39.9 34.3 28.8 23.2 49.8 4.3 48.1 41.4 35.8 30.3 24.7 43.0 4.6 28.0 21.6 67.2 4.8 36.0 29.5 23.1 59.0 4.5 44.0 37.5 31.1 24.6 50.8 4.3 49.7 45.2 38.8 32.3 25.8 43.9 4.6 49.7 45.3 38.8 32.3 25.9 44.9 4.6 30.8 23.4 68.6 4.7 39.4 32.1 24.7 60.3 4.5 48.1 40.7 33.3 26.0 51.9 4.2 51.3 49.1 41.7 34.3 27.0 44.9 4.5 51.3 49.1 41.7 34.4 27.0 45.9 4.5 33.5 25.2 70.0 4.7 42.8 34.6 26.3 61.5 4.4 52.2 43.9 35.6 27.3 53.0 4.1 52.9 52.9 44.6 36.4 28.1 45.8 4.4 52.9 52.9 44.7 36.4 28.1 46.8 4.4 46.0 37.0 27.9 61.6 4.6 56.0 46.9 37.9 28.9 53.1 4.3 53.0 53.0 44.0 35.0 25.9 45.9 4.6 53.1 53.1 44.0 35.0 26.0 46.9 4.7 49.1 39.4 29.6 61.6 4.8 59.8 50.0 40.2 30.4 53.1 4.5 53.2 53.2 43.4 33.6 23.8 45.9 4.8 53.2 53.2 43.4 33.6 23.8 46.9 4.9 90 32.2 40.1 47.9 52.5 36.2 44.8 53.4 54.5 53.9 40.1 49.5 59.0 56.4 55.8 44.0 54.3 64.5 58.4 57.8 57.9 65.7 58.8 58.2 61.6 66.9 59.2 58.5 25.3 35.2 45.1 43.0 31.0 39.4 47.7 43.9 44.9 36.8 43.6 50.4 44.9 45.9 42.5 47.8 53.0 45.8 46.8 51.5 53.1 45.9 46.9 55.3 53.1 45.9 46.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 26.5 20.8 34.3 28.6 22.9 42.1 36.4 30.7 25.0 52.5 43.6 37.8 32.1 29.6 23.0 38.2 31.6 25.0 46.8 40.2 33.6 27.0 54.5 48.1 41.4 34.8 53.9 48.7 42.1 35.4 32.6 25.1 42.0 34.5 27.0 51.5 43.9 36.4 28.9 56.4 52.5 45.0 37.5 55.8 53.2 45.7 38.2 35.6 27.2 45.9 37.5 29.1 56.1 47.7 39.3 30.9 58.4 57.0 48.6 40.2 57.8 57.8 49.4 41.0 48.8 39.7 30.6 59.6 50.5 41.4 32.3 58.8 58.1 49.0 39.9 58.2 58.2 49.1 39.9 51.7 41.9 32.1 63.2 53.4 43.5 33.7 59.2 59.2 49.3 39.5 58.5 58.5 48.7 38.9 105°F 21.7 16.5 29.7 24.3 18.9 37.8 32.1 26.6 21.2 43.0 35.7 30.3 24.8 24.5 18.1 33.0 26.6 20.2 41.5 35.1 28.7 22.3 43.9 39.1 32.7 26.3 44.9 39.9 33.5 27.1 27.3 19.7 36.2 28.9 21.6 45.2 38.1 30.8 23.5 44.9 42.5 35.1 27.8 45.9 43.4 36.0 28.7 30.0 21.2 39.5 31.2 22.9 48.9 41.2 32.9 24.6 45.8 45.8 37.5 29.2 46.8 46.8 38.5 30.3 42.5 33.4 24.3 50.8 44.1 35.0 26.0 45.9 45.9 36.8 27.7 46.9 46.9 37.8 28.7 45.5 35.6 25.8 52.7 47.0 37.2 27.3 45.9 45.9 36.1 26.2 46.9 46.9 37.1 27.2 65 26.4 28.2 28.8 30.0 30.7 31.8 32.6 30.8 30.8 29.7 29.1 19.4 19.9 20.8 20.4 21.4 21.0 22.0 18.7 19.7 16.4 17.4 73 528150-YTG-T-0514 ZR061 (5.0 Ton) Cooling (Continued) Air on Evaporator Coil CFM 1250 1500 1750 2000 2250 2500 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 60.8 52.8 44.7 37.9 61.3 53.2 45.0 38.2 40.1 61.7 53.5 45.3 38.5 40.4 62.2 53.9 45.7 38.8 40.7 53.9 45.6 38.7 40.7 53.8 45.6 38.7 40.6 6.1 5.6 5.0 5.3 5.9 5.4 4.8 5.1 5.2 5.7 5.2 4.7 4.9 5.0 5.5 5.0 4.5 4.8 4.8 5.2 4.7 5.0 5.1 5.5 4.9 5.2 5.3 19.8 32.2 44.7 37.9 27.6 36.3 45.0 38.2 40.1 35.4 40.4 45.3 38.5 40.4 43.2 44.4 45.7 38.8 40.7 48.1 45.6 38.7 40.7 51.7 45.6 38.7 40.6 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 18.1 13.3 55.9 7.3 26.9 21.6 16.2 47.8 6.5 35.7 29.8 24.5 19.1 39.6 5.7 37.9 30.0 24.7 19.4 14.0 32.9 5.9 20.9 14.6 55.4 7.0 30.0 23.6 17.3 47.3 6.2 39.0 32.7 26.4 20.0 39.2 5.4 38.2 32.9 26.6 20.3 14.0 32.5 5.7 40.1 34.6 28.3 22.0 15.6 35.4 5.8 23.8 15.9 54.8 6.7 33.1 25.7 18.4 46.8 5.9 42.3 35.6 28.3 20.9 38.8 5.2 38.5 35.8 28.5 21.2 13.9 32.1 5.4 40.4 37.7 30.3 23.0 15.7 35.0 5.5 26.6 17.2 54.3 6.4 36.1 27.8 19.5 46.3 5.7 45.7 38.5 30.1 21.8 38.3 4.9 38.8 38.8 30.4 22.1 13.8 31.7 5.1 40.7 40.7 32.4 24.1 15.8 34.6 5.2 38.9 29.8 20.7 46.2 5.9 45.6 41.2 32.1 23.0 38.2 5.1 38.7 38.7 29.6 20.5 11.4 31.6 5.4 40.7 40.7 31.6 22.5 13.4 34.5 5.5 41.8 31.9 22.0 46.0 6.1 45.6 44.0 34.1 24.2 38.1 5.3 38.7 38.7 28.8 18.9 9.0 31.5 5.6 40.6 40.6 30.7 20.8 10.9 34.4 5.7 90 18.9 29.2 39.6 32.9 27.2 33.2 39.2 32.5 35.4 35.6 37.2 38.8 32.1 35.0 43.9 41.1 38.3 31.7 34.6 44.6 38.2 31.6 34.5 46.0 38.1 31.5 34.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 12.5 10.1 24.0 18.8 13.6 34.3 27.5 22.3 17.1 32.9 24.3 19.1 13.9 17.4 11.1 27.0 20.7 14.4 36.5 30.3 24.0 17.8 32.5 26.8 20.5 14.3 35.4 29.3 23.0 16.8 22.3 12.2 29.9 22.6 15.3 38.8 33.0 25.7 18.4 32.1 29.2 21.9 14.7 35.0 31.9 24.7 17.4 27.2 13.2 32.8 24.5 16.1 38.3 35.7 27.4 19.1 31.7 31.7 23.4 15.0 34.6 34.6 26.3 18.0 35.4 26.3 17.1 38.2 38.2 29.3 20.1 31.6 31.6 22.4 13.3 34.5 34.5 25.3 16.2 38.1 28.1 18.2 38.1 38.1 31.1 21.2 31.5 31.5 21.5 11.5 34.4 34.4 24.4 14.5 65 8.7 8.0 10.5 7.4 10.1 6.7 9.6 4.1 7.1 1.6 4.5 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 74 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR061 (5.0 Ton) Reheat Air on Evaporator Coil CFM Total Capacity1 (MBh) Total Input (kW)2 62.5 64 65.3 62.5 64 65.3 62.5 64 65.3 26.8 28.9 30.0 29.2 30.8 31.4 29.8 31.2 31.4 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 62.5 64 65.3 62.5 64 65.3 62.5 64 62 26.7 28.9 31.6 27.9 31.0 32.9 26.8 29.5 31.7 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 62.5 64 65.3 62.5 64 65.3 62.5 64 65.3 22.8 25.5 27.8 23.2 25.7 27.8 21.6 23.8 26.1 3.5 3.5 3.5 3.5 3.5 3.5 3.4 3.5 3.5 62.5 64 65.3 62.5 64 65.3 62.5 64 62 17.4 19.7 21.6 17.3 19.4 20.9 16.0 18.0 19.4 3.5 3.6 3.6 3.6 3.6 3.6 3.5 3.6 3.6 WB (°F) Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total (- indicates heating) Capacity1 Return Dry Bulb (°F) (MBh) 75 40 °F 1750 2000 2250 50 °F 8.4 6.4 4.8 11.0 8.6 5.8 10.5 7.6 6.0 29.3 32.4 34.7 30.3 32.3 35.3 29.6 32.1 34.5 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 9.2 6.9 5.4 10.9 8.4 6.7 9.5 6.9 4.5 24.5 27.0 28.7 25.0 27.3 29.6 23.6 26.1 28.2 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 7.1 5.1 3.3 8.0 5.9 4.3 6.8 4.5 1.9 21.3 23.9 25.8 21.3 23.7 25.7 19.5 22.0 24.1 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.9 2.0 -0.3 5.0 2.5 0.5 3.5 0.4 -1.7 8.3 9.8 11.2 7.1 8.8 10.3 5.0 6.1 8.3 3.8 3.8 3.9 3.8 3.8 3.9 3.8 3.8 3.9 60 °F 1750 2000 2250 2000 2250 2000 2250 8.0 6.4 4.3 9.0 6.9 4.9 7.3 4.7 2.7 80 °F 85 °F 1750 10.7 9.2 7.3 11.9 9.9 8.4 11.1 8.5 6.2 70 °F 75 °F 1750 Sensible Capacity (MBh) (- indicates heating) Return Dry Bulb (°F) 75 Total Input (kW)2 6.3 4.6 2.7 7.3 5.3 3.6 5.6 3.1 1.0 95 °F -1.8 -3.9 -5.3 -0.9 -3.0 -5.2 -3.3 -6.2 -8.0 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 75 528150-YTG-T-0514 ZR078 (6.5 Ton) Cooling Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 1625 1950 2275 2600 2925 3250 76 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 99.9 91.5 83.0 72.4 106.5 97.5 88.5 77.2 78.2 113.1 103.5 93.9 81.9 83.1 119.7 109.5 99.4 86.7 87.9 109.6 99.5 86.8 88.0 109.7 99.6 86.9 88.0 5.1 5.0 5.0 4.9 5.1 5.1 5.1 5.0 5.0 5.2 5.2 5.1 5.1 5.1 5.3 5.2 5.2 5.1 5.2 5.2 5.1 5.1 5.1 5.1 5.1 5.0 5.0 39.3 50.3 61.3 72.4 45.5 57.8 70.1 77.2 78.2 51.6 65.2 78.8 81.9 83.1 57.8 72.7 87.6 86.7 87.9 74.8 91.9 86.8 88.0 76.9 96.1 86.9 88.0 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 81.2 75.9 70.7 64.9 87.0 81.4 75.8 69.7 63.0 92.9 87.0 81.0 74.4 67.3 98.8 92.5 86.1 79.1 71.5 90.8 84.5 77.6 70.2 89.1 83.0 76.2 68.9 6.5 6.5 6.4 6.4 6.6 6.5 6.5 6.4 6.5 6.7 6.6 6.6 6.5 6.5 6.7 6.7 6.6 6.6 6.6 6.6 6.6 6.5 6.6 6.6 6.5 6.5 6.5 34.6 45.6 56.7 64.9 40.1 52.5 64.9 69.7 63.0 45.5 59.3 73.2 74.4 67.3 51.0 66.2 81.4 79.1 71.5 68.3 82.2 77.6 70.2 70.4 83.0 76.2 68.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 33.2 27.1 90.5 5.8 44.2 38.1 32.1 83.7 5.7 55.2 49.2 43.1 37.0 76.9 5.7 70.1 60.9 54.9 48.8 42.7 68.7 5.7 37.9 30.3 96.8 5.9 50.2 42.6 35.1 89.5 5.8 62.5 54.9 47.4 39.8 82.2 5.8 75.6 68.1 60.5 52.9 45.4 73.4 5.7 78.2 72.6 65.0 57.5 49.9 70.6 5.7 42.6 33.5 103.0 5.9 56.2 47.1 38.0 95.2 5.9 69.8 60.7 51.6 42.6 87.5 5.8 81.2 75.2 66.2 57.1 48.0 78.1 5.8 83.1 80.3 71.2 62.1 53.1 75.2 5.8 47.3 36.7 109.3 6.0 62.2 51.6 41.0 101.0 6.0 77.0 66.5 55.9 45.3 92.8 5.9 86.7 82.4 71.8 61.3 50.7 82.9 5.9 87.9 87.9 77.4 66.8 56.2 79.7 5.9 64.0 53.1 42.2 100.2 5.9 79.3 68.4 57.5 46.7 92.0 5.9 86.8 84.6 73.8 62.9 52.0 82.2 5.8 88.0 88.0 77.1 66.2 55.3 79.1 5.8 65.7 54.6 43.4 99.4 5.8 81.5 70.3 59.1 48.0 91.3 5.8 86.9 86.9 75.7 64.5 53.4 81.5 5.8 88.0 88.0 76.8 65.6 54.4 78.5 5.8 95°F 28.4 22.3 76.9 7.3 39.5 33.3 27.2 70.8 7.3 50.5 44.4 38.2 32.1 64.7 7.2 63.3 54.3 48.1 42.0 35.8 59.4 7.2 32.5 25.0 81.8 7.4 45.0 37.5 30.0 75.3 7.4 57.4 49.9 42.4 34.9 68.8 7.3 68.6 61.0 53.5 46.0 38.5 63.2 7.3 63.0 58.6 51.1 43.5 36.0 61.6 7.3 36.7 27.8 86.7 7.5 50.5 41.6 32.8 79.8 7.5 64.3 55.4 46.6 37.7 73.0 7.4 73.8 67.8 59.0 50.1 41.2 67.0 7.3 67.3 65.1 56.2 47.3 38.5 65.2 7.4 40.8 30.6 91.6 7.6 56.0 45.8 35.6 84.3 7.6 71.2 61.0 50.8 40.5 77.1 7.5 79.1 74.6 64.4 54.2 43.9 70.8 7.4 71.5 71.5 61.3 51.1 40.9 68.9 7.4 57.6 47.0 36.3 83.1 7.5 73.2 62.6 51.9 41.3 75.9 7.4 77.6 75.4 64.7 54.1 43.4 69.7 7.4 70.2 70.2 59.6 48.9 38.3 67.9 7.4 59.3 48.2 37.1 81.8 7.4 75.3 64.2 53.1 42.0 74.8 7.4 76.2 76.2 65.1 54.0 42.9 68.6 7.3 68.9 68.9 57.8 46.8 35.7 66.9 7.3 90 36.9 48.0 59.0 68.7 42.8 55.1 67.5 73.4 70.6 48.6 62.3 76.0 78.1 75.2 54.4 69.5 84.5 82.9 79.7 71.6 87.0 82.2 79.1 73.7 89.5 81.5 78.5 31.0 43.2 55.3 59.4 37.4 49.6 61.8 63.2 61.6 43.8 56.0 68.3 67.0 65.2 50.2 62.5 74.7 70.8 68.9 64.7 74.8 69.7 67.9 66.9 74.8 68.6 66.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 30.8 24.7 41.8 35.7 29.6 52.9 46.8 40.7 34.5 66.7 57.6 51.5 45.4 35.2 27.7 47.6 40.0 32.5 60.0 52.4 44.9 37.3 72.1 64.6 57.0 49.5 70.6 65.6 58.0 50.5 39.6 30.7 53.3 44.4 35.4 67.0 58.1 49.1 40.1 77.5 71.5 62.6 53.6 75.2 72.7 63.7 54.7 44.0 33.6 59.1 48.7 38.3 74.1 63.7 53.3 42.9 82.9 78.5 68.1 57.7 79.7 79.7 69.3 59.0 60.8 50.0 39.3 76.3 65.5 54.7 44.0 82.2 80.0 69.3 58.5 79.1 79.1 68.3 57.6 62.5 51.4 40.3 78.4 67.3 56.1 45.0 81.5 81.5 70.4 59.3 78.5 78.5 67.3 56.2 105°F 26.2 20.1 37.1 31.0 24.8 47.9 41.8 35.7 29.6 58.5 49.9 43.8 37.7 30.0 22.6 42.2 34.8 27.4 54.4 47.0 39.6 32.1 62.6 56.1 48.7 41.3 61.4 55.5 48.1 40.6 33.8 25.1 47.3 38.6 29.9 60.9 52.2 43.5 34.7 66.7 62.3 53.6 44.9 65.1 61.6 52.9 44.2 37.6 27.6 52.5 42.5 32.5 67.3 57.3 47.3 37.3 70.8 68.5 58.5 48.5 68.9 67.7 57.7 47.7 54.2 43.8 33.3 69.1 59.1 48.7 38.2 69.7 68.6 58.1 47.7 67.9 67.3 56.8 46.4 56.0 45.1 34.2 70.9 60.9 50.0 39.1 68.6 68.6 57.7 46.8 66.9 66.9 56.0 45.1 65 39.3 41.9 43.0 44.6 45.8 47.3 48.6 47.7 46.8 48.1 45.1 31.6 33.9 33.2 36.2 35.5 38.5 37.7 37.2 35.9 35.9 34.2 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078 (6.5 Ton) Cooling (Continued) Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 72.6 65.6 58.6 53.8 76.5 69.1 61.8 56.7 60.1 80.4 72.7 64.9 59.6 63.2 84.3 76.2 68.1 62.5 66.3 75.4 67.3 61.8 65.5 74.5 66.6 61.1 64.8 8.1 8.1 8.1 8.0 8.2 8.2 8.2 8.1 8.1 8.4 8.3 8.3 8.2 8.2 8.5 8.4 8.4 8.3 8.3 8.3 8.3 8.2 8.2 8.3 8.2 8.1 8.1 27.5 40.7 54.0 53.8 34.8 46.7 58.7 56.7 60.1 42.1 52.7 63.4 59.6 63.2 49.4 58.8 68.1 62.5 66.3 61.1 67.3 61.8 65.5 63.4 66.6 61.1 64.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 24.0 18.0 68.3 9.0 34.7 28.6 22.5 60.4 8.9 45.3 39.2 33.1 27.1 52.6 8.9 53.8 45.6 39.5 33.4 27.4 48.2 8.8 27.5 20.2 71.2 9.1 39.4 32.1 24.8 63.0 9.0 51.4 44.0 36.7 29.4 54.7 9.0 56.7 51.2 43.9 36.6 29.3 50.2 8.9 59.7 52.4 45.1 37.7 30.4 58.7 8.9 31.0 22.4 74.1 9.2 44.2 35.6 27.1 65.5 9.2 57.4 48.9 40.3 31.8 56.9 9.1 59.6 56.8 48.3 39.7 31.2 52.2 9.0 63.0 58.1 49.6 41.0 32.5 61.2 9.0 34.4 24.6 77.1 9.3 49.0 39.2 29.4 68.1 9.3 63.5 53.7 43.9 34.1 59.1 9.2 62.5 62.5 52.7 42.9 33.1 54.2 9.1 66.3 63.9 54.1 44.3 34.5 63.6 9.1 50.8 40.6 30.3 67.6 9.2 65.0 55.7 45.4 35.1 58.7 9.2 61.8 61.8 51.5 41.3 31.0 53.8 9.0 65.5 64.3 54.1 43.8 33.6 63.2 9.0 52.7 42.0 31.3 67.2 9.1 66.6 57.6 46.9 36.2 58.4 9.1 61.1 61.1 50.4 39.7 28.9 53.5 8.9 64.8 64.8 54.1 43.4 32.7 62.7 9.0 90 24.0 38.3 52.6 48.2 33.0 43.9 54.7 50.2 58.7 42.0 49.4 56.9 52.2 61.2 51.0 55.0 59.1 54.2 63.6 57.5 58.7 53.8 63.2 59.9 58.4 53.5 62.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 21.5 15.8 32.2 26.2 20.2 42.6 36.6 30.6 24.6 48.2 41.2 35.2 29.2 25.0 17.8 36.6 29.4 22.2 48.3 41.1 33.9 26.7 50.2 46.3 39.1 31.9 58.0 49.3 42.1 34.8 28.4 19.7 41.0 32.6 24.2 54.0 45.6 37.2 28.8 52.2 51.4 43.0 34.6 60.8 54.7 46.3 37.9 31.8 21.6 45.4 35.9 26.3 59.1 50.1 40.5 30.9 54.2 54.2 46.8 37.2 63.6 60.0 50.5 40.9 47.4 37.4 27.3 58.7 52.2 42.1 32.1 53.8 53.8 44.9 34.9 63.2 61.4 51.3 41.3 49.4 38.9 28.3 58.4 54.3 43.7 33.2 53.5 53.5 43.0 32.5 62.7 62.7 52.2 41.7 65 23.1 24.7 27.6 26.2 29.5 27.7 31.3 24.8 31.2 22.0 31.2 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 77 528150-YTG-T-0514 ZR078 (6.5 Ton) Reheat Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 1625 1950 2275 2600 2925 3250 78 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 31.6 32.2 28.5 36.1 36.7 32.6 34.2 40.5 41.2 36.7 38.3 45.0 45.7 40.8 42.5 42.5 43.2 38.5 40.2 40.0 40.6 36.2 37.9 4.5 4.6 4.4 4.3 4.5 4.3 4.4 4.2 4.3 4.2 4.2 4.1 4.2 4.0 4.1 4.0 4.1 4.0 4.0 3.9 4.0 3.9 4.0 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 38.2 38.2 35.5 38.4 38.4 35.7 34.7 38.6 38.6 35.9 34.9 38.8 38.9 36.1 35.1 39.0 39.1 36.3 35.3 39.2 39.3 36.5 35.5 5.7 5.1 5.3 5.5 4.9 5.1 5.1 5.2 4.7 4.9 4.8 5.0 4.4 4.6 4.6 5.2 4.6 4.8 4.8 5.3 4.8 5.0 5.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 35°F 1.6 1.5 1.5 34.9 5.1 1.5 1.5 1.4 1.4 35.2 4.9 1.6 1.6 1.5 1.5 1.4 32.0 4.9 2.2 1.6 0.9 37.2 4.9 6.6 5.9 5.3 4.6 37.6 4.7 10.8 10.1 9.4 8.8 8.1 34.2 4.7 17.1 16.4 15.8 15.1 14.5 34.5 4.7 2.9 1.7 0.4 39.6 4.7 11.6 10.4 9.1 7.8 39.9 4.5 19.9 18.6 17.4 16.1 14.8 36.3 4.5 29.8 29.5 28.2 26.9 25.7 36.6 4.5 3.6 1.7 -0.1 41.9 4.5 16.7 14.8 12.9 11.1 42.3 4.3 29.0 27.1 25.3 23.4 21.6 38.4 4.3 42.5 42.5 40.6 38.7 36.9 38.8 4.4 4.6 2.8 1.0 40.8 4.6 17.5 15.7 13.9 12.1 41.1 4.4 31.6 29.1 27.3 25.5 23.7 37.4 4.4 40.2 40.2 38.3 36.5 34.7 37.7 4.4 5.7 3.9 2.1 39.6 4.6 18.4 16.6 14.8 13.0 40.0 4.4 34.2 31.1 29.3 27.5 25.8 36.3 4.4 37.9 37.9 36.1 34.3 32.5 36.7 4.5 55°F 36.3 5.7 3.4 2.9 2.4 1.9 36.2 5.3 8.8 8.3 7.8 7.3 6.7 33.1 5.2 36.8 5.6 5.8 5.2 4.5 3.9 36.7 5.2 15.3 14.7 14.0 13.3 12.7 33.5 5.0 19.4 18.7 18.1 17.4 16.8 32.9 5.0 37.3 5.4 8.3 7.5 6.6 5.8 37.2 5.0 21.9 21.0 20.2 19.4 18.6 34.0 4.9 27.2 26.9 26.1 25.3 24.5 33.4 4.9 37.8 5.3 10.7 9.7 8.8 7.8 37.7 4.9 28.4 27.4 26.5 25.5 24.6 34.4 4.8 35.1 35.1 34.1 33.2 32.2 33.8 4.8 38.0 5.4 12.9 11.7 10.6 9.5 38.0 5.0 32.4 32.0 30.8 29.7 28.6 34.6 4.9 35.3 35.3 34.2 33.0 31.9 34.1 4.9 38.2 5.5 15.0 13.7 12.5 11.2 38.2 5.0 36.5 36.5 35.2 33.9 32.6 34.8 4.9 35.5 35.5 34.2 32.9 31.6 34.3 4.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 45°F 2.5 2.2 1.9 1.7 5.2 4.9 4.6 4.4 6.2 5.6 4.9 4.2 13.0 12.4 11.7 11.1 18.2 17.6 16.9 16.3 9.9 8.9 7.9 6.8 20.9 19.8 18.8 17.8 28.5 28.2 27.2 26.1 13.7 12.3 10.8 9.4 28.7 27.3 25.9 24.5 38.8 38.8 37.4 36.0 15.2 13.7 12.2 10.8 32.0 30.5 29.1 27.6 37.7 37.7 36.2 34.8 16.7 15.2 13.6 12.1 35.3 33.8 32.3 30.7 36.7 36.7 35.1 33.6 65°F 2.4 2.1 1.8 1.5 6.5 6.2 5.9 5.6 4.9 4.3 3.8 3.2 13.9 13.3 12.7 12.2 17.0 16.5 15.9 15.3 7.4 6.6 5.8 5.0 21.2 20.4 19.6 18.8 25.4 25.2 24.3 23.5 9.9 8.9 7.8 6.8 28.5 27.5 26.4 25.3 33.8 33.8 32.8 31.7 12.2 10.9 9.7 8.4 31.7 31.2 29.9 28.7 34.1 34.1 32.8 31.6 14.4 13.0 11.6 10.1 34.8 34.8 33.4 32.0 34.3 34.3 32.8 31.4 65 4.1 10.4 15.6 16.7 25.1 23.1 34.5 26.1 33.3 29.2 32.0 5.3 11.6 14.8 18.0 22.7 24.3 30.7 27.4 30.3 30.5 29.9 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078 (6.5 Ton) Reheat (Continued) Air on Evaporator Coil CFM 1625 1950 2275 2600 2925 3250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 34.3 34.2 30.6 35.1 35.0 31.3 31.2 35.9 35.8 32.0 31.9 36.7 36.6 32.7 32.6 37.0 36.9 33.0 32.8 37.2 37.1 33.2 33.1 5.7 5.4 5.0 5.7 5.4 5.0 5.0 5.7 5.4 5.0 5.0 5.7 5.4 5.0 5.0 5.6 5.4 4.9 4.9 5.6 5.3 4.9 4.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 32.4 5.6 1.3 1.2 1.1 1.0 32.2 5.6 4.3 4.2 4.1 4.0 3.9 28.2 4.8 33.5 5.8 4.0 3.5 3.0 2.6 33.3 5.7 12.4 12.0 11.5 11.0 10.6 29.1 4.9 14.6 14.2 13.7 13.3 12.8 29.4 4.9 34.5 5.9 6.6 5.8 5.0 4.2 34.4 5.8 20.5 19.7 18.9 18.1 17.3 30.1 5.1 23.6 23.4 22.6 21.8 21.0 30.4 5.0 35.6 6.0 9.2 8.1 6.9 5.7 35.5 5.9 28.7 27.5 26.3 25.2 24.0 31.0 5.2 32.6 32.6 31.4 30.3 29.1 31.3 5.2 35.9 5.8 11.5 10.2 8.8 7.4 35.8 5.8 30.9 30.4 29.0 27.6 26.2 31.3 5.0 32.8 32.8 31.5 30.1 28.7 31.6 5.0 36.2 5.7 13.9 12.3 10.7 9.1 36.1 5.6 33.2 33.2 31.6 30.0 28.4 31.6 4.9 33.1 33.1 31.5 29.9 28.3 31.9 4.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 0.3 0.4 0.5 0.6 2.1 2.2 2.2 2.3 3.0 2.7 2.3 1.9 11.0 10.6 10.3 9.9 12.2 11.9 11.5 11.2 5.7 4.9 4.1 3.3 19.9 19.1 18.3 17.4 21.8 21.6 20.8 20.0 8.5 7.2 6.0 4.7 28.8 27.5 26.3 25.0 31.3 31.3 30.1 28.8 10.9 9.4 7.9 6.4 30.2 29.6 28.0 26.5 31.6 31.6 30.1 28.6 13.3 11.5 9.8 8.0 31.6 31.6 29.8 28.1 31.9 31.9 30.1 28.4 65 2.4 9.5 10.8 16.6 19.2 23.8 27.6 25.0 27.1 26.3 26.6 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 79 528150-YTG-T-0514 ZR090 (7.5 Ton) Cooling Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 1875 2250 2625 3000 3375 3750 80 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 95.3 88.9 82.4 72.3 104.3 97.2 90.1 79.1 76.9 113.3 105.5 97.8 85.9 83.6 122.2 113.8 105.4 92.7 90.2 116.9 108.2 95.1 92.7 119.9 111.0 97.6 95.1 5.1 5.0 4.9 4.9 5.1 5.0 5.0 4.9 4.9 5.2 5.1 5.0 5.0 5.0 5.2 5.1 5.1 5.0 5.0 5.2 5.1 5.1 5.1 5.2 5.1 5.1 5.1 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 101.5 93.1 84.7 76.8 104.3 95.7 87.0 78.9 78.3 107.1 98.2 89.3 81.0 80.4 109.9 100.7 91.6 83.1 82.4 101.5 92.3 83.7 83.1 102.3 93.0 84.3 83.7 6.6 6.6 6.5 6.5 6.6 6.6 6.5 6.5 6.5 6.6 6.6 6.5 6.5 6.5 6.6 6.6 6.5 6.5 6.5 6.6 6.5 6.5 6.5 6.6 6.6 6.5 6.5 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 90 85 80 75 70 65 75°F 41.7 33.4 25.0 98.4 5.8 49.7 41.3 33.0 24.6 91.0 5.8 57.7 49.3 41.0 32.6 24.2 83.6 5.7 72.3 63.4 49.7 41.3 32.9 24.6 74.5 5.7 50.1 40.6 31.2 104.3 5.9 60.3 50.9 41.4 32.0 96.4 5.8 70.6 61.1 51.7 42.2 32.8 88.5 5.8 79.1 73.2 62.8 53.3 43.9 34.4 79.0 5.7 76.9 74.8 63.8 54.3 44.9 35.4 77.6 5.7 58.4 47.9 37.4 110.2 5.9 70.9 60.4 49.9 39.4 101.9 5.8 83.4 72.9 62.4 51.9 41.3 93.5 5.8 85.9 82.9 75.8 65.3 54.8 44.3 83.4 5.7 83.6 82.5 77.0 66.5 55.9 45.4 82.0 5.7 66.8 55.2 43.6 116.0 5.9 81.6 69.9 58.3 46.7 107.3 5.9 96.3 84.7 73.1 61.5 49.9 98.5 5.8 92.7 92.7 88.9 77.3 65.7 54.1 87.9 5.8 90.2 90.2 90.2 78.6 67.0 55.4 86.3 5.8 86.8 74.3 61.8 49.4 109.2 5.9 103.7 89.9 77.5 65.0 52.5 100.3 5.8 95.1 95.1 93.3 80.8 68.4 55.9 89.4 5.8 92.7 92.7 92.7 80.2 67.7 55.3 87.9 5.8 92.0 78.7 65.3 52.0 111.1 5.9 111.0 95.2 81.9 68.5 55.2 102.0 5.8 97.6 97.6 97.6 84.3 71.0 57.7 91.0 5.8 95.1 95.1 95.1 81.8 68.4 55.1 89.4 5.8 95°F 43.2 35.6 27.9 94.5 7.5 55.7 48.0 40.3 32.7 86.4 7.5 68.2 60.5 52.8 45.1 37.4 78.3 7.5 76.8 76.8 65.4 57.7 50.0 42.3 71.2 7.4 47.9 39.1 30.3 96.9 7.5 61.5 52.7 43.9 35.0 88.5 7.5 75.0 66.2 57.4 48.6 39.8 80.2 7.4 78.9 78.9 71.0 62.2 53.4 44.6 73.0 7.4 78.3 78.3 71.1 62.2 53.4 44.6 73.0 7.4 52.6 42.6 32.7 99.2 7.5 67.2 57.3 47.4 37.4 90.6 7.5 81.9 72.0 62.0 52.1 42.1 82.1 7.4 81.0 81.0 76.7 66.8 56.9 46.9 74.7 7.4 80.4 80.4 76.7 66.8 56.9 46.9 74.8 7.4 57.3 46.2 35.1 101.5 7.5 73.0 61.9 50.9 39.8 92.7 7.5 88.7 77.7 66.6 55.6 44.5 84.0 7.4 83.1 83.1 82.4 71.4 60.3 49.2 76.5 7.4 82.4 82.4 82.4 71.4 60.3 49.3 76.5 7.4 78.2 66.2 54.2 42.2 93.0 7.4 90.9 82.9 70.9 58.9 46.9 84.3 7.4 83.7 83.7 83.4 71.4 59.4 47.4 76.7 7.4 83.1 83.1 83.1 71.1 59.1 47.1 76.7 7.4 83.3 70.4 57.5 44.5 93.3 7.4 93.0 88.2 75.2 62.3 49.4 84.5 7.4 84.3 84.3 84.3 71.4 58.5 45.5 76.9 7.4 83.7 83.7 83.7 70.7 57.8 44.9 76.9 7.4 90 42.5 52.7 63.0 74.5 49.0 60.9 72.8 79.0 77.6 55.5 69.1 82.7 83.4 82.0 62.0 77.3 92.5 87.9 86.3 82.5 97.3 89.4 87.9 87.7 102.0 91.0 89.4 39.4 52.8 66.2 71.2 45.1 58.4 71.7 73.0 73.0 50.7 63.9 77.1 74.7 74.8 56.4 69.5 82.6 76.5 76.5 74.7 83.5 76.7 76.7 79.9 84.5 76.9 76.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 34.5 26.4 44.7 36.7 28.6 54.9 46.9 38.9 30.8 70.1 57.5 49.5 41.5 39.9 30.7 51.8 42.6 33.5 63.7 54.5 45.4 36.3 76.0 66.9 57.8 48.6 76.5 67.4 58.3 49.1 45.3 35.0 58.9 48.6 38.4 72.4 62.2 52.0 41.7 82.0 76.3 66.1 55.8 81.4 76.9 66.6 56.4 50.7 39.4 65.9 54.6 43.3 81.2 69.9 58.5 47.2 87.9 85.7 74.3 63.0 86.3 86.3 75.0 63.7 70.2 58.0 45.8 86.4 74.2 62.0 49.7 89.4 88.3 76.1 63.9 87.9 87.9 75.6 63.4 74.5 61.4 48.3 91.7 78.5 65.4 52.3 91.0 91.0 77.9 64.7 89.4 89.4 76.3 63.1 105°F 33.0 25.5 45.3 37.7 30.2 57.5 50.0 42.5 34.9 71.2 60.6 53.1 45.5 36.4 27.7 49.7 41.0 32.3 63.0 54.3 45.6 36.9 73.0 65.8 57.1 48.4 73.0 66.1 57.4 48.7 39.7 29.8 54.1 44.2 34.3 68.4 58.6 48.7 38.8 74.7 70.9 61.1 51.2 74.8 71.3 61.4 51.6 43.0 32.0 58.5 47.4 36.4 73.9 62.8 51.8 40.8 76.5 76.1 65.1 54.1 76.5 76.5 65.5 54.4 62.7 50.8 38.8 78.0 67.3 55.3 43.4 76.7 76.5 64.6 52.6 76.7 76.7 64.8 52.8 67.0 54.1 41.2 82.1 71.7 58.8 46.0 76.9 76.9 64.0 51.1 76.9 76.9 64.0 51.1 65 33.4 39.5 40.0 45.6 46.2 51.7 52.3 51.6 51.2 51.6 50.0 38.0 39.7 40.0 41.4 41.7 43.0 43.4 40.6 40.8 38.2 38.3 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR090 (7.5 Ton) Cooling (Continued) Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 87.6 79.7 71.9 65.7 89.4 81.4 73.4 67.1 67.8 91.2 83.1 74.9 68.5 69.2 93.1 84.7 76.4 69.8 70.6 84.5 76.2 69.6 70.4 84.3 76.0 69.5 70.2 8.4 8.4 8.4 8.3 8.3 8.3 8.4 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.2 35.5 49.9 64.3 65.7 42.2 55.2 68.3 67.1 67.8 48.9 60.6 72.3 68.5 69.2 55.5 66.0 76.4 69.8 70.6 71.2 76.2 69.6 70.4 76.5 76.0 69.5 70.2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 30.5 23.1 80.6 9.2 42.5 35.1 27.8 73.0 9.2 54.6 47.2 39.8 32.4 65.5 9.3 65.7 55.8 48.4 41.1 33.7 60.2 9.3 33.6 25.0 82.0 9.2 46.7 38.1 29.5 74.3 9.2 59.7 51.1 42.6 34.0 66.6 9.3 67.1 60.5 51.9 43.3 34.7 61.2 9.2 67.8 61.1 52.5 43.9 35.4 62.5 9.2 36.8 27.0 83.3 9.2 50.8 41.0 31.2 75.5 9.2 64.9 55.1 45.3 35.5 67.7 9.2 68.5 65.2 55.4 45.6 35.8 62.2 9.2 69.2 65.8 56.0 46.3 36.5 63.6 9.2 39.9 28.9 84.7 9.2 55.0 44.0 33.0 76.7 9.2 70.0 59.1 48.1 37.1 68.8 9.2 69.8 69.8 58.8 47.9 36.9 63.2 9.2 70.6 70.6 59.6 48.6 37.6 64.6 9.2 59.3 47.4 35.5 76.0 9.2 73.0 63.6 51.7 39.8 68.1 9.2 69.6 69.6 57.7 45.8 33.9 62.6 9.2 70.4 70.4 58.4 46.5 34.6 64.0 9.1 63.7 50.8 38.0 75.3 9.1 76.0 68.2 55.4 42.5 67.5 9.2 69.5 69.5 56.6 43.8 30.9 62.0 9.2 70.2 70.2 57.3 44.5 31.6 63.4 9.1 90 30.9 47.0 62.3 60.2 39.3 52.1 64.9 61.2 62.5 47.7 57.3 67.6 62.2 63.6 56.1 62.4 68.8 63.2 64.6 67.8 68.1 62.6 64.0 73.1 67.5 62.0 63.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 27.9 20.7 39.8 32.5 25.3 51.6 44.4 37.2 29.9 60.2 51.0 43.8 36.6 30.9 22.4 43.7 35.2 26.7 56.5 48.0 39.5 31.1 61.2 55.2 46.7 38.3 62.5 56.1 47.7 39.2 33.8 24.1 47.6 37.9 28.2 61.3 51.6 41.9 32.2 62.2 59.4 49.7 40.0 63.6 60.4 50.7 40.9 36.7 25.8 51.5 40.5 29.6 66.2 55.3 44.3 33.4 63.2 63.2 52.6 41.6 64.6 64.6 53.6 42.7 55.9 44.0 32.1 68.1 60.0 48.1 36.2 62.6 62.6 50.9 39.0 64.0 64.0 52.1 40.3 60.3 47.5 34.7 67.5 64.7 51.9 39.1 62.0 62.0 49.2 36.4 63.4 63.4 50.6 37.8 65 29.4 29.8 30.7 30.2 31.2 30.7 31.7 27.1 28.4 23.6 25.0 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 81 528150-YTG-T-0514 ZR090 (7.5 Ton) Reheat Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 1875 2250 2625 3000 3375 3750 82 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 57.4 54.9 52.4 48.7 62.8 60.0 57.2 53.0 49.6 68.1 65.0 61.9 57.4 53.7 73.4 70.0 66.6 61.8 57.8 71.8 68.3 63.3 59.3 73.5 69.9 64.9 60.7 4.6 4.4 4.3 4.1 4.5 4.4 4.2 4.0 4.0 4.5 4.3 4.2 4.0 3.9 4.5 4.3 4.2 4.0 3.9 4.3 4.2 4.0 3.9 4.3 4.2 4.0 3.9 7.7 14.9 21.7 11.2 22.2 32.6 37.1 14.8 29.5 43.6 47.5 18.4 36.8 54.5 57.8 18.9 37.5 58.3 59.3 19.4 38.2 62.1 60.7 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 59.9 54.2 48.5 44.6 62.6 56.6 50.7 46.6 46.2 65.2 59.0 52.8 48.5 48.1 67.8 61.4 54.9 50.5 50.1 63.0 56.4 51.8 51.4 64.6 57.9 53.2 52.7 5.1 4.9 4.7 4.5 5.1 4.9 4.7 4.5 4.4 5.1 4.9 4.6 4.4 4.4 5.1 4.8 4.6 4.4 4.3 4.8 4.6 4.4 4.3 4.8 4.6 4.4 4.3 3.9 12.6 22.2 5.4 17.0 29.9 35.3 6.8 21.4 37.7 42.7 8.2 25.8 45.4 50.1 9.6 29.8 49.3 51.4 11.0 33.9 53.2 52.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 35°F 58.7 4.9 6.3 4.9 3.5 54.6 4.7 13.5 12.1 10.7 9.3 50.5 4.5 20.3 18.9 17.5 16.1 14.7 46.6 4.3 62.7 4.8 9.1 7.0 4.9 58.3 4.6 20.1 18.0 15.9 13.8 53.9 4.4 30.5 28.4 26.3 24.2 22.1 49.8 4.2 35.0 32.9 30.8 28.7 26.6 47.9 4.2 66.6 4.8 12.0 9.2 6.4 62.0 4.6 26.7 23.9 21.1 18.3 57.3 4.4 40.8 38.0 35.2 32.4 29.6 53.0 4.2 46.4 44.0 41.2 38.4 35.6 50.9 4.1 70.6 4.8 14.9 11.4 7.9 65.7 4.6 33.3 29.8 26.3 22.8 60.8 4.4 51.0 47.5 44.0 40.5 37.0 56.1 4.2 57.8 55.1 51.6 48.1 44.6 54.0 4.1 15.5 12.1 8.6 67.4 4.6 34.0 30.6 27.2 23.8 62.3 4.4 53.2 48.3 44.9 41.4 38.0 57.6 4.2 59.3 57.9 54.5 51.1 47.6 55.3 4.1 16.1 12.7 9.4 69.1 4.6 34.8 31.4 28.1 24.7 63.9 4.4 55.3 49.1 45.7 42.4 39.0 59.0 4.2 60.7 60.7 57.4 54.0 50.6 56.7 4.1 55°F 57.9 5.4 2.7 1.6 51.6 5.2 11.4 10.2 9.0 7.9 45.3 5.0 21.0 19.9 18.7 17.5 16.4 42.1 4.8 59.7 5.4 3.7 2.1 53.2 5.2 15.4 13.7 12.1 10.5 46.6 4.9 28.3 26.7 25.1 23.5 21.8 43.4 4.7 33.7 32.1 30.4 28.8 27.2 42.7 4.7 61.4 5.4 4.7 2.7 54.7 5.1 19.3 17.3 15.2 13.1 48.0 4.9 35.6 33.6 31.5 29.4 27.3 44.7 4.7 41.9 40.3 38.2 36.1 34.1 43.9 4.6 63.1 5.3 5.7 3.2 56.2 5.1 23.3 20.8 18.3 15.7 49.4 4.9 42.9 40.4 37.9 35.4 32.8 45.9 4.7 50.1 48.5 46.0 43.4 40.9 45.2 4.6 6.6 3.7 57.9 5.1 26.9 23.9 21.0 18.0 50.8 4.9 48.0 46.5 43.6 40.6 37.6 47.3 4.7 51.4 50.6 47.6 44.7 41.7 46.5 4.6 7.6 4.2 59.6 5.1 30.5 27.1 23.7 20.3 52.3 4.9 53.2 52.7 49.3 45.9 42.5 48.7 4.7 52.7 52.7 49.3 45.9 42.5 47.9 4.6 90 5.8 13.7 21.9 8.3 19.6 31.3 36.2 10.8 25.4 40.6 45.1 13.3 31.3 50.0 54.0 14.3 33.7 53.8 55.3 15.2 36.0 57.6 56.7 1.5 11.0 22.4 2.2 14.3 28.8 33.5 2.9 17.6 35.2 39.3 3.6 20.9 41.7 45.2 4.1 25.7 45.2 46.5 4.6 30.5 48.7 47.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 45°F 4.5 3.2 1.9 12.4 11.1 9.9 8.6 20.7 19.4 18.1 16.8 6.4 4.6 2.7 17.7 15.9 14.0 12.1 29.4 27.6 25.7 23.8 34.3 32.5 30.6 28.8 8.4 5.9 3.5 23.0 20.6 18.1 15.7 38.2 35.8 33.3 30.9 44.1 42.1 39.7 37.3 10.3 7.3 4.3 28.3 25.3 22.3 19.3 47.0 44.0 40.9 37.9 54.0 51.8 48.8 45.8 11.1 7.9 4.7 30.5 27.3 24.1 20.9 50.6 47.4 44.2 41.0 55.3 54.3 51.1 47.9 11.8 8.4 5.1 32.6 29.3 25.9 22.5 54.3 50.9 47.5 44.1 56.7 56.7 53.3 50.0 65°F 10.0 9.0 7.9 6.9 21.4 20.4 19.3 18.3 12.9 11.6 10.2 8.9 27.5 26.1 24.7 23.4 32.2 30.8 29.4 28.1 1.2 15.9 14.2 12.5 10.8 33.5 31.8 30.1 28.4 38.7 37.6 35.9 34.2 1.5 18.9 16.8 14.7 12.7 39.6 37.6 35.5 33.5 45.2 44.4 42.3 40.3 1.5 23.2 20.6 18.0 15.5 44.1 43.0 40.4 37.9 46.5 46.1 43.6 41.0 1.5 27.5 24.4 21.3 18.2 48.7 48.4 45.3 42.2 47.9 47.9 44.8 41.7 65 15.5 22.0 26.9 28.5 34.8 34.9 42.8 37.8 44.7 40.7 46.6 17.3 22.0 26.7 26.7 32.5 31.4 38.2 35.3 38.4 39.2 38.6 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR090 (7.5 Ton) Reheat (Continued) Air on Evaporator Coil CFM 1875 2250 2625 3000 3375 3750 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 56.0 49.0 42.0 39.6 56.8 49.7 42.6 40.2 39.2 57.6 50.4 43.2 40.8 39.7 58.4 51.1 43.8 41.4 40.3 52.8 45.3 42.8 41.6 54.5 46.8 44.1 43.0 5.7 5.5 5.2 5.0 5.7 5.5 5.2 5.0 4.9 5.7 5.4 5.2 5.0 4.9 5.6 5.4 5.2 5.0 4.9 5.4 5.2 5.0 4.9 5.4 5.1 4.9 4.9 9.4 22.6 11.6 27.7 31.7 13.8 32.8 36.0 16.0 37.9 40.3 21.6 41.0 41.6 27.2 44.1 43.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 54.0 6.0 46.3 5.8 8.6 7.7 6.8 6.0 38.7 5.5 21.7 20.9 20.0 19.1 18.3 37.2 5.3 53.9 6.0 46.2 5.7 10.5 9.4 8.3 7.2 38.6 5.5 26.6 25.5 24.4 23.3 22.2 37.0 5.3 30.6 29.5 28.4 27.3 26.2 35.6 5.2 53.8 5.9 46.1 5.7 12.5 11.1 9.8 8.4 38.4 5.5 31.5 30.1 28.8 27.4 26.1 36.9 5.3 35.5 34.9 33.6 32.2 30.9 35.5 5.2 53.6 5.9 45.9 5.7 14.4 12.8 11.2 9.7 38.2 5.4 36.3 34.7 33.2 31.6 30.0 36.8 5.3 40.3 40.3 38.7 37.1 35.5 35.4 5.2 47.7 5.7 19.4 17.3 15.1 12.9 39.7 5.4 40.2 39.4 37.3 35.1 32.9 38.2 5.2 41.6 41.6 39.5 37.3 35.1 36.7 5.2 49.5 5.6 24.4 21.7 18.9 16.2 41.2 5.4 44.1 44.1 41.4 38.6 35.9 39.6 5.2 43.0 43.0 40.2 37.5 34.7 38.1 5.1 90 7.8 22.7 8.9 26.5 30.0 10.0 30.4 32.7 11.1 34.2 35.4 17.5 36.9 36.7 23.9 39.6 38.1 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 7.1 6.4 5.8 5.1 22.0 21.3 20.7 20.0 8.1 7.3 6.4 5.6 25.7 24.9 24.0 23.2 29.1 28.3 27.4 26.6 9.0 8.1 7.1 6.1 29.4 28.4 27.4 26.4 32.2 32.2 31.2 30.3 10.0 8.9 7.7 6.6 33.0 31.9 30.8 29.7 35.4 35.4 35.0 33.9 15.7 13.9 12.2 10.4 36.3 35.9 34.1 32.4 36.7 36.7 35.4 33.6 21.4 19.0 16.6 14.1 39.6 39.6 37.5 35.0 38.1 38.1 35.7 33.3 65 19.3 22.4 25.8 25.5 29.3 28.5 32.8 30.6 31.8 32.6 30.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 83 528150-YTG-T-0514 ZR102 (8.5 Ton) Cooling Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 2125 2550 2975 3400 3825 4250 84 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 121.9 118.1 114.3 105.8 126.3 122.4 118.4 109.7 107.0 130.7 126.6 122.6 113.5 110.8 135.1 130.9 126.7 117.3 114.5 130.9 126.8 117.4 114.5 131.0 126.8 117.4 114.6 6.4 6.4 6.3 6.2 6.5 6.4 6.4 6.2 6.3 6.5 6.4 6.4 6.3 6.3 6.5 6.5 6.4 6.3 6.4 6.5 6.4 6.3 6.4 6.5 6.5 6.3 6.4 54.3 71.1 87.8 105.8 59.7 79.1 98.4 109.7 107.0 65.1 87.0 108.9 113.5 110.8 70.6 95.0 119.5 117.3 114.5 99.4 123.1 117.4 114.5 103.7 126.8 117.4 114.6 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 115.5 107.5 99.5 91.9 119.5 111.3 103.0 95.2 92.1 123.6 115.1 106.5 98.5 95.2 127.7 118.9 110.1 101.7 98.4 119.8 110.9 102.5 99.2 120.8 111.8 103.3 99.9 8.3 8.1 8.0 7.9 8.3 8.2 8.0 7.9 7.9 8.3 8.2 8.0 7.9 8.0 8.4 8.2 8.1 8.0 8.0 8.3 8.1 8.0 8.0 8.3 8.1 8.0 8.1 50.3 66.9 83.4 91.9 57.6 75.0 92.3 95.2 92.1 64.9 83.1 101.2 98.5 95.2 72.3 91.2 110.1 101.7 98.4 97.1 110.9 102.5 99.2 103.1 111.8 103.3 99.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 43.2 32.9 118.7 7.4 60.8 50.5 40.2 112.8 7.3 78.4 68.1 57.8 47.5 106.9 7.2 98.7 83.7 73.4 63.1 52.8 98.9 7.0 47.9 36.1 122.9 7.4 67.3 55.5 43.7 116.8 7.3 86.6 74.8 63.0 51.2 110.7 7.2 104.9 92.0 80.2 68.4 56.6 102.4 7.1 107.0 97.1 85.3 73.5 61.7 99.6 7.1 52.7 39.4 127.2 7.4 73.7 60.5 47.2 120.9 7.3 94.8 81.5 68.2 54.9 114.6 7.2 111.1 100.2 86.9 73.6 60.3 106.0 7.1 110.8 105.8 92.5 79.2 65.9 103.0 7.2 57.4 42.6 131.4 7.4 80.2 65.4 50.6 124.9 7.3 103.0 88.2 73.4 58.6 118.4 7.2 117.3 108.5 93.7 78.9 64.1 109.5 7.1 114.5 114.5 99.7 84.9 70.1 106.5 7.2 84.1 68.8 53.5 125.4 7.4 108.1 92.8 77.5 62.2 118.8 7.3 117.4 112.9 97.6 82.3 67.0 109.9 7.1 114.5 114.5 99.2 83.9 68.6 106.9 7.2 87.9 72.1 56.3 125.9 7.4 113.1 97.3 81.5 65.7 119.3 7.3 117.4 117.4 101.6 85.8 70.0 110.4 7.2 114.6 114.6 98.8 83.0 67.2 107.3 7.2 95°F 41.1 31.1 108.8 9.3 56.8 46.8 36.8 100.5 9.1 72.5 62.5 52.5 42.4 92.1 9.0 91.9 76.8 66.8 56.7 46.7 85.2 8.9 46.0 34.3 112.4 9.3 63.3 51.6 39.9 103.8 9.2 80.6 68.9 57.2 45.6 95.1 9.0 95.2 84.7 73.0 61.3 49.7 88.0 8.9 92.1 82.9 71.2 59.6 47.9 85.8 9.0 50.8 37.5 115.9 9.4 69.7 56.4 43.1 107.0 9.2 88.7 75.3 62.0 48.7 98.1 9.0 98.5 92.6 79.3 65.9 52.6 90.8 8.9 95.2 90.7 77.3 64.0 50.7 88.5 9.0 55.6 40.7 119.5 9.4 76.2 61.2 46.3 110.3 9.2 96.7 81.8 66.8 51.8 101.2 9.1 101.7 100.5 85.5 70.6 55.6 93.6 8.9 98.4 98.4 83.4 68.5 53.5 91.2 9.0 81.0 64.9 48.8 111.2 9.3 102.8 86.7 70.6 54.5 102.0 9.1 102.5 101.9 85.8 69.7 53.6 94.3 9.0 99.2 99.2 83.1 67.0 50.9 92.0 9.1 85.9 68.6 51.4 112.1 9.3 108.9 91.7 74.4 57.2 102.8 9.1 103.3 103.3 86.1 68.9 51.6 95.1 9.0 99.9 99.9 82.7 65.5 48.3 92.7 9.1 90 52.3 69.0 85.6 98.9 58.7 77.0 95.3 102.4 99.6 65.0 85.0 105.1 106.0 103.0 71.4 93.1 114.8 109.5 106.5 98.3 117.0 109.9 106.9 103.4 119.3 110.4 107.3 44.7 63.5 82.4 85.2 54.4 71.5 88.6 88.0 85.8 64.2 79.5 94.9 90.8 88.5 74.0 87.6 101.2 93.6 91.2 93.4 102.0 94.3 92.0 99.2 102.8 95.1 92.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 42.1 32.0 58.8 48.6 38.5 75.4 65.3 55.1 45.0 95.3 80.2 70.1 59.9 46.9 35.2 65.3 53.5 41.8 83.6 71.9 60.1 48.4 100.1 88.3 76.6 64.9 99.6 90.0 78.3 66.5 51.7 38.4 71.7 58.4 45.1 91.7 78.4 65.1 51.8 104.8 96.4 83.1 69.8 103.0 98.2 84.9 71.6 56.5 41.7 78.2 63.3 48.4 99.9 85.0 70.1 55.2 109.5 104.5 89.6 74.7 106.5 106.5 91.6 76.7 82.6 66.9 51.2 105.4 89.7 74.0 58.4 109.9 107.4 91.7 76.0 106.9 106.9 91.2 75.5 86.9 70.4 53.9 111.0 94.5 78.0 61.5 110.4 110.4 93.8 77.3 107.3 107.3 90.7 74.2 105°F 38.2 28.2 53.6 43.7 33.8 69.0 59.1 49.2 39.3 85.2 70.3 60.4 50.5 42.9 31.3 60.0 48.4 36.8 77.1 65.5 53.9 42.3 88.0 77.9 66.3 54.7 85.8 76.4 64.9 53.3 47.5 34.3 66.3 53.1 39.8 85.1 71.8 58.6 45.4 90.8 85.4 72.2 58.9 88.5 83.8 70.6 57.4 52.2 37.3 72.7 57.8 42.9 93.1 78.2 63.3 48.4 93.6 93.0 78.1 63.2 91.2 91.2 76.4 61.5 77.4 61.3 45.3 97.2 83.0 67.0 51.0 94.3 94.0 78.0 61.9 92.0 92.0 75.9 59.9 82.1 64.9 47.7 101.3 87.8 70.7 53.5 95.1 95.1 77.9 60.7 92.7 92.7 75.5 58.4 65 49.8 53.1 54.8 56.5 58.3 59.8 61.8 60.3 59.8 60.8 57.7 40.6 43.1 41.7 45.7 44.1 48.3 46.6 45.9 43.9 43.5 41.2 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR102 (8.5 Ton) Cooling (Continued) Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 102.2 93.5 84.8 78.5 105.2 96.2 87.3 80.8 79.6 108.2 99.0 89.8 83.1 81.8 111.2 101.7 92.3 85.4 84.1 102.6 93.0 86.1 84.8 103.4 93.8 86.8 85.5 10.3 10.1 10.0 9.9 10.4 10.2 10.0 9.9 10.0 10.4 10.2 10.0 9.9 10.0 10.4 10.2 10.0 9.9 10.0 10.3 10.1 10.0 10.1 10.3 10.1 10.0 10.1 39.0 60.2 81.3 78.5 51.2 68.1 85.0 80.8 79.6 63.4 76.0 88.6 83.1 81.8 75.7 84.0 92.3 85.4 84.1 89.7 93.0 86.1 84.8 95.4 93.8 86.8 85.5 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 35.2 25.4 95.6 11.4 50.4 40.6 30.8 86.5 11.1 65.5 55.8 46.0 36.2 77.4 10.9 78.5 63.8 54.0 44.2 34.4 71.8 10.8 39.7 28.3 98.0 11.4 56.6 45.2 33.7 88.7 11.2 73.5 62.0 50.6 39.1 79.4 11.0 80.8 71.0 59.6 48.1 36.6 73.6 10.9 79.6 69.9 58.5 47.0 35.5 73.3 11.0 44.3 31.1 100.5 11.4 62.9 49.7 36.6 90.9 11.2 81.5 68.3 55.2 42.1 81.4 11.0 83.1 78.2 65.1 51.9 38.8 75.4 10.9 81.8 77.0 63.9 50.7 37.6 75.1 11.0 48.8 34.0 102.9 11.4 69.1 54.3 39.5 93.1 11.2 89.5 74.6 59.8 45.0 83.3 11.0 85.4 85.4 70.6 55.8 41.0 77.3 10.9 84.1 84.1 69.3 54.5 39.6 77.0 11.0 73.7 57.7 41.8 93.9 11.3 91.6 79.3 63.3 47.4 84.0 11.1 86.1 86.1 70.1 54.2 38.2 77.9 11.0 84.8 84.8 68.8 52.8 36.9 77.6 11.1 78.3 61.1 44.0 94.7 11.4 93.8 84.0 66.9 49.7 84.7 11.1 86.8 86.8 69.7 52.6 35.4 78.6 11.1 85.5 85.5 68.3 51.2 34.1 78.2 11.2 90 36.2 56.8 77.4 71.8 49.9 64.7 79.4 73.6 73.3 63.7 72.5 81.4 75.4 75.1 77.4 80.4 83.3 77.3 77.0 86.0 84.0 77.9 77.6 91.6 84.7 78.6 78.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 31.0 22.6 47.1 37.5 27.8 62.1 52.4 42.7 33.1 71.8 57.3 47.7 38.0 36.6 25.3 53.3 41.9 30.6 70.0 58.6 47.3 35.9 73.6 64.2 52.8 41.5 73.3 63.4 52.1 40.7 42.3 28.0 59.5 46.4 33.4 77.9 64.8 51.8 38.7 75.4 71.0 58.0 44.9 75.1 70.2 57.1 44.1 47.9 30.7 65.6 50.9 36.1 83.3 71.1 56.3 41.6 77.3 77.3 63.1 48.4 77.0 77.0 62.2 47.5 70.1 54.1 38.2 84.0 75.6 59.7 43.8 77.9 77.9 62.3 46.4 77.6 77.6 61.7 45.8 74.5 57.4 40.3 84.7 80.2 63.1 46.0 78.6 78.6 61.5 44.4 78.2 78.2 61.2 44.1 65 28.3 30.1 29.3 31.9 31.0 33.6 32.7 30.5 29.8 27.3 27.0 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 85 528150-YTG-T-0514 ZR102 (8.5 Ton) Reheat Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 2125 2550 2975 3400 3825 4250 86 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72.0 74.0 61.6 73.3 75.3 62.6 58.2 74.5 76.7 63.6 59.2 75.7 78.1 64.7 60.2 73.9 76.5 63.0 58.8 72.0 75.0 61.4 57.4 5.0 4.9 5.1 4.9 4.8 5.0 4.7 4.8 4.7 5.0 4.7 4.7 4.6 4.9 4.6 4.7 4.6 4.9 4.6 4.7 4.6 4.9 4.6 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 53.3 49.0 46.3 56.3 51.8 49.0 43.2 59.4 54.6 51.6 45.5 62.4 57.4 54.3 47.9 66.2 60.9 57.6 50.8 70.1 64.5 60.9 53.7 6.1 5.8 5.4 6.0 5.7 5.4 5.3 6.0 5.7 5.4 5.3 6.0 5.7 5.3 5.2 5.9 5.6 5.3 5.2 5.9 5.6 5.3 5.2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 35°F 8.5 7.1 5.7 62.7 5.5 11.6 10.2 8.8 7.3 61.5 5.3 21.8 20.4 18.9 17.5 16.1 53.9 5.3 13.4 11.3 9.2 64.8 5.5 17.9 15.8 13.7 11.6 63.6 5.3 33.6 31.5 29.4 27.3 25.2 55.8 5.2 37.4 35.3 33.2 31.2 29.1 50.7 5.0 18.2 15.5 12.7 66.9 5.4 24.1 21.4 18.7 15.9 65.7 5.2 45.3 42.6 39.9 37.1 34.4 57.6 5.2 48.8 47.8 45.0 42.3 39.6 52.4 5.0 23.0 19.6 16.2 69.1 5.3 30.4 27.0 23.6 20.2 67.8 5.1 57.1 53.7 50.4 47.0 43.6 59.5 5.1 60.2 60.2 56.8 53.5 50.1 54.0 4.9 25.8 22.4 18.9 70.1 5.3 33.7 30.2 26.8 23.3 68.7 5.1 62.0 60.1 56.7 53.2 49.8 60.3 5.1 58.8 58.8 55.4 51.9 48.4 54.8 4.9 28.7 25.1 21.6 71.0 5.3 37.0 33.5 29.9 26.4 69.7 5.1 61.4 61.4 61.4 59.5 55.9 61.2 5.1 57.4 57.4 53.9 50.4 46.8 55.6 4.9 55°F 48.0 6.2 7.3 6.5 5.7 4.9 42.2 6.1 14.6 13.9 13.1 12.3 11.5 39.1 5.8 53.6 6.1 11.9 10.5 9.1 7.7 47.0 6.1 23.8 22.4 21.0 19.6 18.1 43.5 5.7 28.6 27.1 25.7 24.3 22.9 36.3 5.7 59.2 6.1 16.6 14.5 12.5 10.4 51.7 6.0 33.0 31.0 28.9 26.8 24.8 47.8 5.7 38.2 37.5 35.4 33.4 31.3 39.8 5.6 64.8 6.1 21.3 18.5 15.8 13.1 56.5 6.0 42.2 39.5 36.8 34.1 31.4 52.2 5.7 47.9 47.9 45.2 42.4 39.7 43.3 5.6 67.4 6.0 24.7 21.4 18.1 14.9 58.8 6.0 48.8 45.6 42.3 39.0 35.8 54.4 5.6 50.8 50.8 47.5 44.3 41.0 45.2 5.6 70.0 6.0 28.1 24.2 20.4 16.6 61.1 5.9 55.5 51.6 47.8 44.0 40.2 56.5 5.6 53.7 53.7 49.9 46.1 42.3 47.1 5.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 45°F 3.5 2.4 1.3 9.5 8.4 7.2 6.1 18.2 17.1 16.0 14.9 5.6 3.8 2.1 14.9 13.2 11.4 9.7 28.7 26.9 25.2 23.4 33.0 31.2 29.5 27.7 7.6 5.2 2.8 20.4 18.0 15.6 13.2 39.2 36.8 34.4 32.0 43.5 42.6 40.2 37.8 9.7 6.6 3.6 25.8 22.8 19.7 16.7 49.7 46.6 43.6 40.5 54.0 54.0 51.0 47.9 10.9 7.5 4.2 29.2 25.8 22.5 19.1 55.4 52.9 49.5 46.1 54.8 54.8 51.4 48.1 12.1 8.4 4.7 32.5 28.9 25.2 21.5 61.2 59.1 55.4 51.7 55.6 55.6 51.9 48.2 65°F 4.4 4.0 3.5 3.1 9.5 9.1 8.6 8.2 9.1 8.0 6.9 5.8 20.2 19.1 18.0 16.9 22.6 21.5 20.4 19.3 13.7 12.0 10.2 8.5 30.9 29.1 27.4 25.7 33.0 32.4 30.7 28.9 18.3 15.9 13.6 11.2 41.6 39.2 36.8 34.4 43.3 43.3 41.0 38.6 22.2 19.2 16.3 13.3 47.7 45.5 42.6 39.6 45.2 45.2 42.2 39.3 26.0 22.5 19.0 15.4 53.8 51.9 48.3 44.8 47.1 47.1 43.5 40.0 65 13.8 21.7 26.0 29.6 35.4 37.5 44.9 42.8 44.7 48.0 44.5 7.7 15.8 18.2 23.9 27.2 32.0 36.2 36.6 36.3 41.2 36.4 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR102 (8.5 Ton) Reheat (Continued) Air on Evaporator Coil CFM 2125 2550 2975 3400 3825 4250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 42.8 35.4 31.9 50.9 42.1 38.0 29.4 59.1 48.9 44.0 34.1 67.2 55.6 50.1 38.8 68.6 56.7 51.1 39.6 69.9 57.8 52.1 40.4 6.3 6.5 6.2 6.2 6.4 6.1 6.1 6.2 6.4 6.1 6.0 6.2 6.3 6.0 6.0 6.1 6.3 6.0 5.9 6.1 6.3 5.9 5.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 37.6 6.4 1.6 1.5 1.4 1.2 28.6 6.8 4.4 4.3 4.2 4.1 4.0 24.7 6.5 48.3 6.4 6.2 5.4 4.7 3.9 37.3 6.8 16.6 15.8 15.0 14.3 13.5 32.5 6.5 16.6 15.8 15.0 14.3 13.5 22.5 6.4 58.9 6.3 10.8 9.4 8.0 6.6 46.0 6.7 28.7 27.3 25.9 24.5 23.1 40.2 6.4 27.7 27.3 25.9 24.5 23.1 28.4 6.4 69.6 6.3 15.4 13.3 11.3 9.2 54.7 6.7 40.9 38.8 36.8 34.7 32.6 48.0 6.4 38.8 38.8 36.8 34.7 32.6 34.3 6.3 69.7 6.2 19.7 17.0 14.4 11.7 54.6 6.6 46.5 45.5 42.8 40.1 37.5 47.9 6.3 39.6 39.6 36.9 34.3 31.6 34.0 6.3 69.8 6.2 24.0 20.8 17.5 14.2 54.5 6.6 52.1 52.1 48.8 45.6 42.3 47.7 6.3 40.4 40.4 37.1 33.9 30.6 33.7 6.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 3.3 2.9 2.5 2.0 13.0 12.5 12.1 11.6 10.6 10.1 9.7 9.3 7.9 6.8 5.7 4.6 26.6 25.5 24.4 23.3 22.4 22.2 21.1 20.0 12.5 10.7 9.0 7.3 40.2 38.5 36.7 35.0 34.3 34.3 32.6 30.8 17.2 14.9 12.5 10.2 45.3 45.4 43.1 40.7 34.0 34.0 31.6 29.3 22.0 19.0 16.0 13.1 47.7 47.7 47.7 46.4 33.7 33.7 30.7 27.8 65 11.2 8.8 22.2 19.0 33.3 29.1 38.3 26.9 43.4 24.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 87 528150-YTG-T-0514 ZR120 (10 Ton) Cooling Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 2500 3000 3500 4000 4500 5000 88 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 137.8 131.8 125.8 113.9 143.9 137.6 131.3 118.9 114.8 150.0 143.4 136.9 123.9 119.6 156.1 149.3 142.5 129.0 124.5 151.7 144.8 131.1 126.6 154.2 147.2 133.3 128.6 7.3 7.1 7.0 6.9 7.4 7.2 7.0 6.9 6.9 7.4 7.2 7.1 7.0 7.0 7.4 7.3 7.1 7.0 7.0 7.3 7.1 7.0 7.0 7.3 7.2 7.1 7.1 67.5 85.5 103.5 113.9 73.5 93.3 113.1 118.9 114.8 79.5 101.1 122.7 123.9 119.6 85.5 108.9 132.2 129.0 124.5 116.7 139.7 131.1 126.6 124.5 147.2 133.3 128.6 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 127.3 119.8 112.4 103.2 132.4 124.6 116.9 107.3 106.5 137.4 129.4 121.3 111.4 110.6 142.5 134.1 125.8 115.5 114.7 136.0 127.5 117.1 116.2 137.8 129.2 118.6 117.8 9.2 9.1 9.0 9.0 9.2 9.1 9.0 9.0 8.9 9.2 9.2 9.1 9.0 9.0 9.3 9.2 9.1 9.0 9.0 9.2 9.1 9.0 9.0 9.2 9.1 9.0 9.0 57.6 75.9 94.3 103.2 65.2 85.0 104.8 107.3 106.5 72.9 94.1 115.3 111.4 110.6 80.5 103.1 125.8 115.5 114.7 110.2 127.5 117.1 116.2 117.3 129.2 118.6 117.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 55.5 43.9 132.5 8.2 73.9 62.3 50.6 125.8 8.1 92.3 80.6 69.0 57.4 119.1 8.0 112.8 97.5 85.8 74.2 62.6 108.5 7.9 60.4 47.3 138.1 8.3 80.2 67.1 54.0 131.1 8.2 100.0 86.9 73.8 60.7 124.1 8.0 118.2 105.1 92.0 78.9 65.8 113.1 8.0 114.8 108.3 95.2 82.2 69.1 110.6 7.9 65.3 50.8 143.7 8.3 86.5 72.0 57.4 136.4 8.2 107.7 93.2 78.6 64.0 129.1 8.1 123.6 112.7 98.1 83.5 69.0 117.7 8.0 119.6 116.2 101.6 87.0 72.5 115.1 8.0 70.2 54.2 149.3 8.4 92.8 76.8 60.8 141.7 8.2 115.4 99.4 83.4 67.4 134.1 8.1 129.0 120.2 104.2 88.2 72.2 122.2 8.0 124.5 124.0 108.0 91.9 75.9 119.6 8.0 99.1 81.6 64.0 143.8 8.2 123.1 105.6 88.0 70.5 136.2 8.1 131.1 126.7 109.2 91.6 74.1 124.1 8.0 126.6 126.3 108.8 91.2 73.7 121.4 8.0 105.4 86.4 67.3 146.0 8.3 130.9 111.8 92.7 73.6 138.2 8.1 133.3 133.3 114.2 95.1 76.0 125.9 8.1 128.6 128.6 109.6 90.5 71.4 123.2 8.0 95°F 47.1 36.2 117.5 10.5 65.0 54.1 43.3 110.8 10.4 83.0 72.1 61.2 50.3 104.0 10.3 101.2 84.7 73.8 62.9 52.0 96.1 10.2 52.5 39.8 122.4 10.5 72.3 59.6 46.9 115.4 10.4 92.1 79.4 66.7 54.0 108.3 10.3 106.0 93.3 80.6 67.9 55.2 100.1 10.2 106.5 96.1 83.4 70.7 58.0 99.2 10.2 58.0 43.5 127.3 10.5 79.6 65.1 50.6 120.0 10.4 101.2 86.7 72.2 57.7 112.6 10.3 110.7 101.8 87.3 72.8 58.3 104.0 10.2 110.6 104.9 90.4 75.9 61.4 103.2 10.2 63.5 47.2 132.1 10.5 86.8 70.5 54.3 124.6 10.4 110.2 93.9 77.6 61.3 117.0 10.3 115.5 110.4 94.1 77.8 61.5 108.0 10.2 114.7 113.7 97.4 81.1 64.8 107.1 10.2 92.4 74.7 56.9 126.1 10.4 117.2 99.4 81.7 63.9 118.4 10.3 117.1 114.5 96.7 79.0 61.2 109.4 10.2 116.2 115.8 98.0 80.2 62.5 108.4 10.2 98.0 78.8 59.5 127.6 10.4 124.2 104.9 85.7 66.4 119.8 10.3 118.6 118.6 99.4 80.2 60.9 110.7 10.2 117.8 117.8 98.6 79.3 60.1 109.8 10.2 90 62.6 80.7 98.9 108.5 69.4 89.1 108.9 113.1 110.6 76.2 97.6 119.0 117.7 115.1 83.0 106.0 129.0 122.2 119.6 113.4 133.6 124.1 121.4 120.9 138.2 125.9 123.2 52.8 72.3 91.8 96.1 61.8 81.0 100.2 100.1 99.2 70.7 89.6 108.6 104.0 103.2 79.6 98.3 117.0 108.0 107.1 105.2 118.4 109.4 108.4 112.0 119.8 110.7 109.8 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 51.3 40.0 69.5 58.2 46.9 87.6 76.4 65.1 53.9 107.0 91.1 79.8 68.6 56.5 43.6 76.3 63.4 50.5 96.0 83.1 70.2 57.4 112.1 99.2 86.3 73.4 110.6 102.2 89.3 76.4 61.7 47.1 83.0 68.5 54.0 104.4 89.9 75.4 60.9 117.1 107.2 92.7 78.2 115.1 110.5 96.0 81.5 66.8 50.7 89.8 73.7 57.5 112.8 96.7 80.5 64.4 122.2 115.3 99.2 83.0 119.6 118.9 102.7 86.5 95.8 78.1 60.5 120.2 102.5 84.9 67.2 124.1 120.6 103.0 85.3 121.4 121.0 103.4 85.7 101.7 82.6 63.4 127.5 108.3 89.2 70.0 125.9 125.9 106.8 87.6 123.2 123.2 104.1 84.9 105°F 44.2 33.5 61.6 50.9 40.3 79.1 68.4 57.7 47.0 95.1 80.3 69.6 58.9 49.3 36.9 68.5 56.1 43.7 87.8 75.3 62.9 50.5 99.4 88.5 76.0 63.6 99.2 89.5 77.0 64.6 54.5 40.3 75.5 61.3 47.2 96.5 82.3 68.1 54.0 103.7 96.6 82.5 68.3 103.2 97.7 83.6 69.4 59.6 43.7 82.4 66.5 50.6 105.2 89.3 73.4 57.5 108.0 104.8 88.9 73.0 107.1 106.0 90.1 74.2 87.8 70.5 53.1 111.2 94.6 77.2 59.9 109.4 107.8 90.4 73.1 108.4 107.9 90.5 73.2 93.2 74.4 55.6 117.3 99.9 81.1 62.2 110.7 110.7 91.9 73.1 109.8 109.8 91.0 72.1 65 57.3 60.5 63.5 63.7 67.0 66.8 70.4 67.6 68.1 68.5 65.7 48.2 51.2 52.2 54.2 55.3 57.1 58.3 55.7 55.8 54.3 53.3 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR120 (10 Ton) Cooling (Continued) Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 107.7 101.7 95.6 89.0 112.4 106.1 99.8 92.8 91.9 117.1 110.6 104.0 96.7 95.7 121.8 115.0 108.2 100.6 99.6 116.2 109.3 101.7 100.6 117.5 110.5 102.7 101.7 11.9 11.7 11.6 11.4 11.8 11.7 11.5 11.3 11.4 11.8 11.7 11.5 11.3 11.4 11.8 11.6 11.5 11.3 11.4 11.6 11.5 11.3 11.4 11.7 11.5 11.3 11.4 48.1 68.7 89.3 89.0 58.3 76.9 95.6 92.8 91.9 68.5 85.2 101.9 96.7 95.7 78.7 93.4 108.2 100.6 99.6 100.1 109.3 101.7 100.6 106.8 110.5 102.7 101.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 41.3 30.8 98.0 13.2 58.2 47.7 37.3 92.6 13.0 75.1 64.6 54.2 43.7 87.3 12.8 89.0 75.9 65.4 54.9 44.4 81.8 12.6 46.1 34.0 102.5 13.1 64.8 52.6 40.5 96.9 13.0 83.4 71.3 59.1 47.0 91.3 12.8 92.8 83.7 71.5 59.4 47.2 85.6 12.5 91.9 82.8 70.7 58.5 46.4 84.6 12.7 51.0 37.2 107.0 13.1 71.4 57.5 43.7 101.2 12.9 91.8 77.9 64.1 50.3 95.3 12.7 96.7 91.5 77.6 63.8 50.0 89.4 12.5 95.7 90.5 76.7 62.9 49.1 88.3 12.6 55.8 40.3 111.5 13.0 77.9 62.5 47.0 105.4 12.8 100.1 84.6 69.1 53.6 99.3 12.7 100.6 99.3 83.8 68.3 52.8 93.1 12.4 99.6 98.3 82.8 67.3 51.8 92.0 12.6 83.2 66.2 49.3 106.4 12.9 105.3 89.7 72.8 55.8 100.2 12.7 101.7 101.0 84.1 67.1 50.2 94.0 12.4 100.6 100.0 83.1 66.1 49.2 92.9 12.6 88.4 70.0 51.6 107.3 12.9 110.5 94.8 76.4 58.1 101.1 12.7 102.7 102.7 84.4 66.0 47.6 94.8 12.5 101.7 101.7 83.3 65.0 46.6 93.7 12.7 90 43.3 65.1 86.8 81.8 54.8 72.9 91.0 85.6 84.6 66.3 80.8 95.2 89.4 88.3 77.8 88.6 99.3 93.1 92.0 95.1 100.2 94.0 92.9 101.5 101.1 94.8 93.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 38.4 28.1 54.8 44.5 34.3 71.2 60.9 50.6 40.4 81.8 71.4 61.2 50.9 42.9 31.1 61.0 49.2 37.3 79.1 67.2 55.4 43.5 85.6 78.9 67.0 55.1 84.6 76.2 64.3 52.4 47.5 34.0 67.3 53.8 40.3 87.1 73.6 60.1 46.6 89.4 86.3 72.8 59.3 88.3 83.4 69.9 56.4 52.0 36.9 73.5 58.4 43.3 95.0 79.9 64.8 49.7 93.1 93.1 78.6 63.5 92.0 90.5 75.4 60.3 78.5 62.0 45.5 99.3 84.8 68.3 51.8 94.0 94.0 77.7 61.2 92.9 92.1 75.6 59.1 83.6 65.6 47.7 101.1 89.8 71.8 53.9 94.8 94.8 76.8 58.9 93.7 93.7 75.7 57.8 65 40.6 43.2 40.5 45.8 42.9 48.4 45.3 44.7 42.5 40.9 39.8 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 89 528150-YTG-T-0514 ZR120 (10 Ton) Reheat Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 2500 3000 3500 4000 4500 5000 90 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 81.3 75.9 70.6 72.8 82.4 76.7 71.0 73.6 65.6 83.5 77.5 71.5 74.3 66.1 84.7 78.3 71.9 75.1 66.6 79.5 73.3 76.3 67.8 80.8 74.7 77.5 69.0 6.2 6.1 6.0 5.8 6.2 6.0 5.9 5.7 5.7 6.1 6.0 5.9 5.7 5.6 6.1 6.0 5.9 5.7 5.6 6.0 5.9 5.7 5.6 6.0 5.9 5.7 5.6 12.0 26.3 42.2 15.1 31.5 50.1 56.8 18.1 36.6 58.0 61.7 21.2 41.8 66.0 66.6 22.5 44.3 71.7 67.8 23.8 46.7 77.5 69.0 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 52.1 55.3 58.4 52.2 56.5 59.8 63.2 56.5 55.7 60.8 64.4 68.0 60.8 60.0 65.1 69.0 72.8 65.2 64.2 66.7 70.4 63.0 62.1 64.4 68.0 60.9 60.0 7.4 6.9 6.5 6.2 7.4 6.9 6.5 6.2 6.1 7.3 6.9 6.5 6.2 6.1 7.3 6.9 6.5 6.2 6.1 7.0 6.6 6.3 6.2 7.0 6.6 6.3 6.2 1.2 16.2 28.2 2.0 22.5 39.0 46.2 2.9 28.9 49.8 55.2 3.7 35.3 60.6 64.2 4.1 37.8 60.7 62.1 4.5 40.4 60.9 60.0 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 35°F 66.7 6.8 9.6 7.1 4.7 65.6 6.5 23.9 21.5 19.1 16.6 64.5 6.2 39.7 37.3 34.9 32.5 30.0 62.5 6.0 69.4 6.8 12.1 9.2 6.2 68.3 6.5 28.6 25.6 22.7 19.7 67.1 6.2 47.2 44.2 41.3 38.3 35.4 65.0 6.0 53.9 50.9 48.0 45.0 42.1 60.6 5.9 72.1 6.7 14.7 11.2 7.8 70.9 6.5 33.2 29.7 26.3 22.8 69.7 6.2 54.6 51.1 47.7 44.2 40.8 67.6 6.0 60.2 58.7 55.3 51.8 48.4 63.0 5.9 74.9 6.7 17.2 13.3 9.3 73.6 6.4 37.8 33.9 29.9 25.9 72.4 6.2 62.0 58.0 54.1 50.1 46.1 70.1 5.9 66.6 66.6 62.6 58.6 54.7 65.4 5.9 18.3 14.1 9.9 73.1 6.5 40.1 35.9 31.7 27.5 71.9 6.2 67.7 61.5 57.3 53.1 49.0 69.7 6.0 67.8 67.8 63.6 59.4 55.2 64.9 5.9 19.4 15.0 10.6 72.6 6.5 42.3 38.0 33.6 29.2 71.4 6.2 73.5 65.0 60.6 56.2 51.8 69.2 6.0 69.0 69.0 64.6 60.2 55.8 64.5 5.9 55°F 46.4 7.7 49.0 7.3 14.7 13.2 11.7 10.2 51.6 6.9 26.7 25.2 23.7 22.3 20.8 46.1 6.5 51.3 7.7 54.1 7.3 20.3 18.1 15.8 13.6 57.0 6.8 36.8 34.5 32.3 30.1 27.8 50.8 6.5 44.0 41.7 39.5 37.3 35.0 50.2 6.5 56.1 7.7 59.2 7.3 25.9 22.9 20.0 17.0 62.3 6.8 46.8 43.9 40.9 37.9 34.9 55.6 6.5 54.1 53.0 50.0 47.0 44.0 54.9 6.5 60.9 7.7 64.3 7.2 31.5 27.8 24.1 20.4 67.6 6.8 56.9 53.2 49.4 45.7 42.0 60.4 6.5 64.2 64.2 60.5 56.8 53.0 59.6 6.5 63.3 7.3 33.8 29.7 25.7 21.6 66.7 6.9 58.9 56.8 52.8 48.7 44.7 59.5 6.6 62.1 62.1 58.0 54.0 49.9 58.8 6.5 62.4 7.3 36.0 31.7 27.3 22.9 65.7 6.9 60.9 60.5 56.2 51.8 47.4 58.6 6.6 60.0 60.0 55.6 51.2 46.8 57.9 6.5 90 6.6 21.3 35.2 8.5 27.0 44.6 51.5 10.5 32.8 53.9 58.4 12.5 38.5 63.3 65.4 13.3 41.1 66.2 64.9 14.1 43.6 69.2 64.5 13.0 23.7 19.4 34.9 40.6 25.7 46.2 50.1 32.0 57.5 59.6 36.0 58.0 58.8 40.0 58.6 57.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 45°F 4.6 2.7 19.3 17.3 15.4 13.4 33.2 31.3 29.3 27.4 6.0 3.4 24.4 21.8 19.3 16.7 42.0 39.4 36.8 34.2 48.9 46.3 43.7 41.1 7.3 4.1 29.6 26.3 23.1 19.9 50.7 47.5 44.3 41.1 57.1 55.9 52.6 49.4 8.6 4.8 34.7 30.8 27.0 23.1 59.4 55.6 51.7 47.9 65.4 65.4 61.5 57.7 9.2 5.1 36.9 32.8 28.7 24.6 63.3 59.2 55.1 50.9 64.9 64.9 60.8 56.7 9.8 5.4 39.2 34.8 30.4 26.0 67.2 62.8 58.4 54.0 64.5 64.5 60.1 55.7 65°F 11.8 10.6 9.4 8.2 22.5 21.3 20.0 18.8 17.4 15.4 13.5 11.5 33.0 31.0 29.0 27.1 38.6 36.6 34.7 32.7 23.0 20.2 17.5 14.8 43.5 40.7 38.0 35.3 49.1 48.1 45.4 42.6 28.5 25.1 21.6 18.1 54.0 50.5 47.0 43.5 59.6 59.6 56.1 52.6 32.0 28.0 24.0 20.0 56.3 54.5 50.5 46.5 58.8 58.7 54.7 50.7 35.5 31.0 26.5 22.0 58.6 58.5 53.9 49.4 57.9 57.9 53.4 48.9 65 25.4 31.6 38.6 37.8 46.2 44.1 53.8 46.8 52.6 49.6 51.3 17.6 25.1 30.7 32.5 39.9 40.0 49.1 42.5 46.7 44.9 44.4 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR120 (10 Ton) Reheat (Continued) Air on Evaporator Coil CFM 2500 3000 3500 4000 4500 5000 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 40.8 42.8 44.9 39.9 46.1 48.4 50.7 45.2 44.8 51.4 54.0 56.6 50.4 49.9 56.7 59.6 62.4 55.6 55.1 60.0 62.9 56.0 55.5 60.5 63.4 56.4 55.9 8.0 7.6 7.2 6.9 8.0 7.6 7.2 6.8 6.8 8.0 7.6 7.1 6.8 6.8 8.0 7.6 7.1 6.8 6.8 7.6 7.2 6.9 6.8 7.7 7.2 6.9 6.9 9.9 19.1 16.2 30.9 34.9 22.5 42.6 45.0 28.8 54.3 55.1 34.2 55.4 55.5 39.7 56.4 55.9 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 35.1 8.4 36.6 8.0 9.0 8.1 7.1 6.2 38.1 7.5 18.2 17.3 16.3 15.4 14.5 33.8 7.2 40.9 8.4 42.7 7.9 14.5 12.8 11.1 9.4 44.5 7.5 29.2 27.5 25.7 24.0 22.3 39.5 7.2 33.2 31.5 29.8 28.1 26.4 39.3 7.1 46.7 8.3 48.8 7.9 20.0 17.5 15.1 12.6 50.9 7.5 40.1 37.6 35.1 32.7 30.2 45.1 7.1 44.2 43.2 40.7 38.3 35.8 44.9 7.1 52.5 8.3 54.9 7.9 25.6 22.3 19.0 15.8 57.3 7.4 51.1 47.8 44.6 41.3 38.0 50.8 7.1 55.1 54.9 51.7 48.4 45.1 50.5 7.1 56.7 7.9 30.3 26.3 22.4 18.4 59.2 7.5 53.7 52.1 48.1 44.2 40.2 52.5 7.2 55.5 55.4 51.4 47.5 43.5 52.2 7.1 58.5 8.0 35.0 30.4 25.7 21.0 61.0 7.5 56.4 56.4 51.7 47.1 42.4 54.2 7.2 55.9 55.9 51.2 46.6 41.9 53.9 7.2 90 6.8 14.6 13.0 26.8 29.3 19.3 39.0 39.9 25.6 50.8 50.5 32.4 52.5 52.2 39.3 54.2 53.9 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 6.1 5.5 4.8 4.2 13.9 13.3 12.6 12.0 11.6 10.2 8.7 7.3 25.3 23.9 22.5 21.0 27.9 26.4 25.0 23.6 17.1 14.8 12.6 10.4 36.8 34.5 32.3 30.0 39.2 38.4 36.1 33.9 22.6 19.5 16.5 13.4 48.2 45.1 42.1 39.1 50.5 50.3 47.2 44.2 28.5 24.6 20.7 16.8 51.2 49.7 45.8 41.9 52.2 52.1 48.2 44.2 34.5 29.7 24.9 20.1 54.2 54.2 49.5 44.7 53.9 53.9 49.1 44.3 65 11.3 19.6 22.1 27.8 31.6 36.0 41.2 38.0 40.3 39.9 39.5 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 91 528150-YTG-T-0514 ZR150 (12.5 Ton) Cooling Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 3125 3750 4375 5000 5625 6250 92 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 190.5 180.7 171.0 158.6 199.8 189.6 179.4 166.3 154.4 209.1 198.4 187.7 174.1 161.6 218.4 207.3 196.1 181.8 168.8 211.2 199.9 185.3 172.0 215.2 203.6 188.8 175.3 9.0 9.2 9.3 9.1 9.2 9.3 9.4 9.2 9.2 9.3 9.4 9.6 9.4 9.3 9.4 9.6 9.7 9.5 9.5 9.6 9.7 9.5 9.5 9.5 9.7 9.5 9.4 87.6 111.5 135.4 158.6 94.7 119.8 145.0 166.3 154.4 101.9 128.2 154.5 174.1 161.6 109.0 136.6 164.1 181.8 168.8 148.0 179.4 185.3 172.0 159.4 194.6 188.8 175.3 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 180.0 165.1 150.2 137.5 188.2 172.7 157.1 143.8 139.4 196.5 180.3 164.0 150.1 145.5 204.8 187.8 170.9 156.4 151.6 193.2 175.8 160.9 156.0 198.6 180.7 165.4 160.3 11.9 11.8 11.7 11.5 12.0 11.9 11.7 11.6 11.6 12.0 11.9 11.8 11.6 11.7 12.1 12.0 11.9 11.7 11.7 12.0 11.9 11.7 11.7 12.0 11.9 11.7 11.8 75.6 99.3 123.0 137.5 83.2 109.0 134.8 143.8 139.4 90.7 118.6 146.6 150.1 145.5 98.3 128.3 158.4 156.4 151.6 138.6 169.6 160.9 156.0 148.9 180.7 165.4 160.3 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 73.4 59.1 185.2 10.5 97.2 83.0 68.8 172.9 10.5 121.1 106.9 92.7 78.4 160.6 10.5 158.6 158.6 150.5 136.2 122.0 148.0 10.3 78.6 62.4 194.0 10.6 103.7 87.5 71.3 181.1 10.6 128.8 112.6 96.4 80.3 168.3 10.6 166.3 166.3 157.9 141.8 125.6 155.1 10.4 154.4 148.9 132.7 116.6 100.4 146.9 10.4 83.8 65.7 202.8 10.7 110.1 92.0 73.9 189.3 10.7 136.4 118.3 100.2 82.1 175.9 10.7 174.1 174.1 165.4 147.3 129.2 162.1 10.5 161.6 156.6 138.5 120.4 102.3 153.5 10.5 89.0 68.9 211.6 10.8 116.5 96.5 76.5 197.5 10.8 144.1 124.1 104.0 84.0 183.5 10.8 181.8 181.8 172.9 152.9 132.8 169.1 10.6 168.8 164.4 144.3 124.3 104.2 160.2 10.6 126.6 105.3 83.9 202.2 10.8 156.7 135.4 114.0 92.7 187.8 10.8 185.3 185.3 169.5 148.2 126.8 173.1 10.6 172.0 169.8 148.5 127.1 105.8 164.0 10.6 136.7 114.0 91.4 206.9 10.8 169.4 146.7 124.0 101.4 192.2 10.8 188.8 188.8 166.2 143.5 120.9 177.1 10.6 175.3 175.3 152.6 130.0 107.3 167.8 10.6 95°F 61.3 46.9 168.2 13.3 85.0 70.6 56.3 153.8 13.2 108.6 94.3 80.0 65.6 139.5 13.0 133.0 114.6 100.2 85.9 71.5 127.9 12.9 67.2 51.2 175.5 13.3 93.0 77.0 60.9 160.6 13.2 118.8 102.8 86.7 70.7 145.6 13.1 140.8 124.8 108.8 92.8 76.8 133.5 12.9 139.4 125.8 109.8 93.8 77.7 130.3 13.0 73.0 55.4 182.9 13.4 101.0 83.3 65.6 167.3 13.3 128.9 111.2 93.5 75.8 151.8 13.1 148.6 135.1 117.4 99.7 82.0 139.2 13.0 145.5 136.1 118.4 100.7 83.1 135.7 13.0 78.9 59.6 190.3 13.4 109.0 89.6 70.2 174.1 13.3 139.0 119.6 100.3 80.9 157.9 13.2 156.4 145.3 126.0 106.6 87.2 144.8 13.0 151.6 146.4 127.1 107.7 88.4 141.2 13.1 117.4 96.2 75.1 178.5 13.3 149.7 128.5 107.3 86.1 161.8 13.2 160.9 155.4 134.2 113.0 91.8 148.4 13.0 156.0 153.4 132.2 111.0 89.8 144.7 13.1 125.9 102.9 79.9 182.8 13.3 160.4 137.4 114.4 91.4 165.8 13.2 165.4 165.4 142.4 119.4 96.4 152.0 13.0 160.3 160.3 137.3 114.3 91.3 148.3 13.1 90 81.6 105.4 129.2 148.0 89.0 114.4 139.9 155.1 146.9 96.3 123.4 150.6 162.1 153.5 103.6 132.4 161.2 169.1 160.2 143.3 174.5 173.1 164.0 154.1 187.7 177.1 167.8 71.8 95.1 118.4 127.9 79.5 104.5 129.4 133.5 130.3 87.3 113.9 140.5 139.2 135.7 95.1 123.3 151.6 144.8 141.2 133.3 158.7 148.4 144.7 143.3 165.8 152.0 148.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 67.3 53.0 91.1 76.8 62.5 114.9 100.6 86.3 72.0 148.0 139.6 125.3 111.1 72.9 56.8 98.3 82.2 66.1 123.8 107.7 91.6 75.5 155.1 149.5 133.4 117.3 146.9 137.3 121.2 105.2 78.4 60.5 105.5 87.6 69.7 132.7 114.8 96.9 79.0 162.1 159.3 141.4 123.5 153.5 146.4 128.5 110.6 83.9 64.2 112.7 93.0 73.3 141.5 121.8 102.1 82.4 169.1 169.1 149.4 129.7 160.2 155.4 135.7 116.0 122.0 100.8 79.5 153.2 131.9 110.7 89.4 173.1 173.1 151.9 130.6 164.0 161.6 140.3 119.1 131.3 108.5 85.6 164.9 142.0 119.2 96.4 177.1 177.1 154.3 131.5 167.8 167.8 145.0 122.1 105°F 58.0 43.9 81.0 66.9 52.8 103.9 89.8 75.7 61.6 125.7 110.1 96.0 81.9 63.7 47.8 88.6 72.8 56.9 113.6 97.7 81.9 66.0 132.1 119.8 104.0 88.1 130.3 117.1 101.2 85.4 69.3 51.7 96.3 78.7 61.0 123.3 105.6 88.0 70.4 138.4 129.5 111.9 94.3 135.7 126.6 109.0 91.3 75.0 55.6 104.0 84.6 65.2 132.9 113.6 94.2 74.8 144.8 139.2 119.8 100.4 141.2 136.1 116.7 97.3 112.3 91.2 70.2 143.5 122.5 101.5 80.4 148.4 145.6 124.6 103.5 144.7 142.2 121.1 100.1 120.6 97.9 75.2 154.1 131.4 108.7 86.1 152.0 152.0 129.3 106.6 148.3 148.3 125.6 102.9 65 96.8 101.2 89.1 105.6 92.7 110.0 96.3 109.3 97.8 108.6 99.3 67.8 72.2 69.5 76.6 73.7 81.1 77.9 82.5 79.1 84.0 80.2 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR150 (12.5 Ton) Cooling (Continued) Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 90 77 72 67 62 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 72 67 62 57 72 67 62 57 156.3 142.6 128.8 118.4 162.8 148.5 134.1 123.3 121.1 169.3 154.4 139.5 128.2 126.0 175.8 160.3 144.9 133.1 130.8 163.7 147.9 135.9 133.5 167.0 150.9 138.6 136.2 14.6 14.5 14.4 14.2 14.7 14.6 14.4 14.3 14.3 14.7 14.6 14.5 14.3 14.4 14.8 14.7 14.5 14.4 14.4 14.7 14.5 14.4 14.4 14.7 14.5 14.4 14.4 67.9 90.8 113.7 118.4 75.9 100.0 124.1 123.3 121.1 83.9 109.2 134.5 128.2 126.0 91.9 118.4 144.9 133.1 130.8 128.0 147.9 135.9 133.5 137.7 150.9 138.6 136.2 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 115°F 54.8 40.9 144.5 16.0 77.0 63.1 49.3 131.3 15.9 99.1 85.3 71.5 57.6 118.1 15.7 118.4 105.7 91.8 78.0 64.1 108.8 15.6 60.2 44.5 150.2 16.0 84.3 68.6 52.9 136.4 15.9 108.4 92.7 77.0 61.3 122.7 15.8 123.3 114.8 99.1 83.4 67.7 113.0 15.6 121.1 108.4 92.7 77.0 61.3 112.0 15.7 65.6 48.0 155.8 16.1 91.6 74.1 56.5 141.5 16.0 117.6 100.1 82.5 65.0 127.2 15.8 128.2 124.0 106.4 88.8 71.3 117.3 15.7 126.0 117.1 99.5 81.9 64.4 116.2 15.7 71.0 51.6 161.4 16.2 98.9 79.5 60.1 146.6 16.0 126.9 107.5 88.1 68.6 131.8 15.9 133.1 133.1 113.7 94.3 74.9 121.5 15.7 130.8 125.7 106.3 86.9 67.5 120.4 15.8 107.1 86.2 65.3 148.9 16.0 137.4 116.5 95.6 74.7 133.9 15.9 135.9 135.9 115.0 94.1 73.2 123.4 15.7 133.5 131.0 110.1 89.2 68.3 122.3 15.8 115.3 92.9 70.5 151.2 16.0 147.9 125.5 103.1 80.7 135.9 15.8 138.6 138.6 116.3 93.9 71.5 125.3 15.7 136.2 136.2 113.9 91.5 69.1 124.2 15.7 90 60.9 86.6 110.3 108.8 72.3 95.5 118.8 113.0 112.0 83.6 104.5 127.2 117.3 116.2 95.0 113.4 131.8 121.5 120.4 122.7 133.9 123.4 122.3 132.0 135.9 125.3 124.2 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 51.5 37.9 73.0 59.4 45.8 94.4 80.8 67.2 53.6 108.8 102.4 87.6 74.0 56.7 41.2 80.0 64.4 48.9 103.2 87.7 72.1 56.6 113.0 109.8 94.3 78.7 112.0 99.7 84.2 68.6 61.9 44.4 87.0 69.5 52.0 112.0 94.5 77.0 59.5 117.3 117.3 100.9 83.4 116.2 107.5 90.0 72.6 67.0 47.6 93.9 74.5 55.1 120.8 101.4 82.0 62.5 121.5 121.5 107.6 88.1 120.4 115.4 95.9 76.5 102.0 81.2 60.4 131.3 110.5 89.7 69.0 123.4 123.4 105.4 84.6 122.3 119.8 99.0 78.3 110.0 87.9 65.8 135.9 119.6 97.5 75.4 125.3 125.3 103.2 81.1 124.2 124.2 102.1 80.0 65 60.4 63.2 53.1 65.9 55.1 68.7 57.0 63.9 57.5 59.0 58.0 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 93 528150-YTG-T-0514 ZR150 (12.5 Ton) Reheat Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 3125 3750 4375 5000 5625 6250 94 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 87.0 84.6 82.9 89.0 86.5 84.8 82.2 90.9 88.4 86.6 84.0 92.8 90.3 88.5 85.9 94.1 91.5 89.7 87.1 95.4 92.8 91.0 88.3 7.7 7.3 7.3 7.4 7.1 7.1 7.7 7.2 6.9 6.8 7.4 6.9 6.6 6.6 7.1 7.5 7.1 7.1 7.7 8.0 7.7 7.6 8.3 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 84.8 81.9 78.7 88.8 85.8 82.5 76.1 92.8 89.7 86.2 79.5 96.8 93.6 89.9 83.0 99.3 96.0 92.2 85.1 101.8 98.4 94.6 87.2 8.9 8.7 8.2 8.6 8.3 7.8 8.7 8.2 8.0 7.5 8.3 7.8 7.6 7.1 8.0 8.2 8.0 7.5 8.4 8.6 8.4 7.9 8.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 35°F 6.6 4.8 3.1 85.9 8.3 14.4 12.7 11.0 9.2 83.3 8.0 20.3 18.6 16.9 15.2 13.5 80.8 7.7 11.5 9.2 6.9 88.9 8.0 26.3 24.0 21.7 19.5 86.2 7.7 36.7 34.4 32.1 29.8 27.5 83.6 7.4 43.1 40.9 38.6 36.3 34.0 79.1 8.2 16.4 13.5 10.7 91.8 7.7 38.3 35.4 32.5 29.7 89.1 7.4 53.1 50.2 47.4 44.5 41.6 86.4 7.2 63.2 60.0 57.1 54.2 51.4 81.8 7.9 21.3 17.9 14.4 94.8 7.4 50.2 46.8 43.3 39.9 91.9 7.1 69.5 66.0 62.6 59.1 55.7 89.2 6.9 83.2 79.1 75.6 72.2 68.7 84.4 7.6 15.2 12.5 9.9 96.7 7.8 35.5 32.8 30.2 27.5 93.8 7.6 48.0 45.4 42.7 40.1 37.4 91.0 7.3 58.0 55.0 52.4 49.7 47.1 86.1 8.0 9.1 7.2 5.4 98.6 8.3 20.7 18.9 17.0 15.2 95.6 8.0 26.6 24.7 22.9 21.0 19.2 92.8 7.8 32.9 31.0 29.2 27.3 25.5 87.8 8.5 55°F 4.6 2.9 1.2 84.2 9.3 9.3 7.6 5.9 4.2 79.1 8.9 15.1 13.4 11.7 10.0 8.3 74.6 8.4 9.9 7.4 5.0 87.3 9.2 21.9 19.4 16.9 14.5 82.0 8.8 36.5 34.1 31.6 29.1 26.7 77.4 8.3 38.4 36.0 33.5 31.0 28.6 72.6 9.0 15.2 11.9 8.7 90.4 9.1 34.4 31.2 27.9 24.7 85.0 8.7 58.0 54.7 51.5 48.3 45.0 80.2 8.2 60.7 57.8 54.6 51.3 48.1 75.2 8.9 20.5 16.5 12.4 93.5 9.0 47.0 42.9 38.9 34.9 87.9 8.6 79.4 75.4 71.4 67.4 63.4 83.0 8.1 83.0 79.6 75.6 71.6 67.6 77.8 8.8 17.4 13.6 9.8 97.7 9.2 39.3 35.5 31.8 28.0 91.8 8.8 66.2 62.4 58.7 54.9 51.1 86.6 8.3 69.3 65.9 62.1 58.4 54.6 81.2 9.0 14.3 10.8 7.3 101.9 9.5 31.7 28.1 24.6 21.1 95.7 9.1 53.0 49.4 45.9 42.4 38.8 90.3 8.6 55.7 52.2 48.7 45.1 41.6 84.7 9.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 45°F 5.6 3.9 2.2 11.8 10.1 8.4 6.7 17.7 16.0 14.3 12.6 10.7 8.3 5.9 24.1 21.7 19.3 17.0 36.6 34.2 31.9 29.5 40.8 38.4 36.0 33.7 15.8 12.7 9.7 36.3 33.3 30.2 27.2 55.5 52.5 49.4 46.4 61.9 58.9 55.8 52.8 20.9 17.2 13.4 48.6 44.9 41.1 37.4 74.5 70.7 67.0 63.3 83.1 79.4 75.6 71.9 16.3 13.1 9.9 37.4 34.2 31.0 27.8 57.1 53.9 50.7 47.5 63.7 60.5 57.3 54.1 11.7 9.0 6.3 26.2 23.5 20.8 18.1 39.8 37.1 34.4 31.7 44.3 41.6 38.9 36.2 65°F 10.4 8.9 7.3 5.8 24.9 23.4 21.8 20.3 18.2 16.0 13.9 11.8 40.0 37.9 35.8 33.7 44.1 42.0 39.9 37.8 25.9 23.2 20.5 17.8 55.1 52.4 49.8 47.1 60.3 57.7 55.1 52.4 1.1 33.6 30.4 27.1 23.8 70.3 67.0 63.7 60.4 76.4 73.5 70.2 66.9 31.7 28.3 25.0 21.6 69.4 66.0 62.6 59.3 72.7 70.3 66.9 63.6 29.8 26.3 22.8 19.4 68.5 65.0 61.6 58.1 68.9 67.1 63.7 60.2 65 10.9 27.1 31.3 43.3 49.7 59.5 68.2 44.3 50.8 29.0 33.5 18.7 31.5 35.6 44.4 49.7 57.2 63.7 55.9 60.2 54.6 56.8 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR150 (12.5 Ton) Reheat (Continued) Air on Evaporator Coil CFM 3125 3750 4375 5000 5625 6250 WB (°F) Total Capacity1 (MBh) Total Input (kW)2 72 67 62 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 83.6 76.2 70.5 85.8 78.2 72.3 69.0 88.0 80.2 74.2 70.8 90.1 82.2 76.0 72.6 96.1 87.6 81.0 77.3 102.0 93.0 86.0 82.1 9.7 9.2 8.7 9.9 9.3 8.8 9.3 10.0 9.4 8.9 9.5 10.1 9.5 9.0 9.6 10.3 9.6 9.1 9.7 10.4 9.8 9.2 9.8 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1 Input (MBh) (kW)2 85 80 75 70 65 75°F 83.0 10.2 11.5 10.1 8.7 7.3 73.4 9.4 34.8 33.4 32.0 30.6 29.2 66.4 8.9 84.3 10.5 14.5 12.7 10.9 9.1 74.4 9.7 43.6 41.8 40.0 38.2 36.4 67.3 9.3 49.8 48.1 46.3 44.5 42.7 65.5 9.7 85.5 10.9 17.4 15.2 13.1 10.9 75.5 10.1 52.3 50.2 48.0 45.8 43.7 68.2 9.6 59.9 57.7 55.5 53.4 51.2 66.4 10.0 86.8 11.3 20.3 17.8 15.2 12.7 76.5 10.5 61.1 58.5 56.0 53.5 50.9 69.1 10.0 69.9 67.3 64.8 62.3 59.7 67.4 10.4 94.4 11.3 24.1 21.1 18.1 15.2 83.4 10.5 72.5 69.6 66.6 63.7 60.7 75.4 9.9 76.0 74.7 71.8 68.8 65.8 73.4 10.4 102.0 11.3 27.8 24.5 21.1 17.7 90.3 10.4 84.0 80.6 77.2 73.8 70.5 81.7 9.9 82.1 82.1 78.7 75.3 71.9 79.5 10.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 85°F 12.6 11.4 10.1 8.8 44.7 43.4 42.1 40.9 10.8 9.3 7.9 6.4 47.1 45.6 44.2 42.7 55.5 54.1 52.7 51.2 8.9 7.2 5.6 4.0 49.5 47.9 46.2 44.6 59.4 57.6 56.0 54.4 7.0 5.2 3.4 1.6 51.9 50.1 48.3 46.5 63.3 61.2 59.4 57.6 16.4 13.9 11.3 8.8 75.4 73.1 70.6 68.0 73.4 73.4 73.4 73.4 25.9 22.6 19.3 16.0 81.7 81.7 81.7 81.7 79.5 79.5 79.5 79.5 65 39.6 41.3 49.8 43.0 52.8 44.7 55.8 65.5 71.5 81.7 79.5 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Johnson Controls Unitary Products 95 528150-YTG-T-0514 Drive Selection 1. Determine side or bottom supply duct Application. 2. Determine desired airflow. 3. Calculate or measure the amount of external static pressure. • Add or deduct any additional static resistance from “Additional Static Resistance Table”. 4. Using the operating point determined from steps 1, 2 & 3, locate this point on the appropriate supply air blower performance table. (Linear interpolation may be necessary.) 5. Noting the RPM and BHP from step 4, locate the appropriate motor and, or drive on the RPM selection table. 6. Review the BHP compared to the motor options available. Select the appropriate motor and, or drive. 7. Review the RPM range for the motor options available. Select the appropriate drive if multiple drives are available for the chosen motor. 8. Determine turns open to obtain the desired operation point. Example 1. 2600 CFM 2. 1.6 iwg 3. Using the supply air blower performance table below, the following data point was located: 1268 RPM & 1.95 BHP. 4. Using the RPM selection table below, Size X and Model Y is found. 5. 1.95 BHP exceeds the maximum continuous BHP rating of the 1.5 HP motor. The 2 HP motor is required. 6. 1268 RPM is within the range of the 2 HP drives. 7. Using the 2 HP motor and drive, .5 turns open will achieve 1268 RPM. Airflow Performance Example Supply Air Blower Performance Air Flow (CFM) 2200 2400 2600 2800 Available External Static Pressure - IWG 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 804 835 869 906 0.50 0.66 0.84 1.03 1.5 HP & Field Supplied Drive 866 0.71 925 0.90 982 897 0.87 956 1.06 1013 931 1.05 990 1.24 1047 968 1.25 1027 1.43 1084 1.06 1.22 1.40 1.60 1038 1069 1103 1139 Standard 1.5 HP & Drive 1.21 1092 1.35 1147 1.37 1124 1.51 1178 1.55 1158 1.69 1212 1.75 1194 1.89 1249 1.48 1.64 1.82 2.02 1203 1234 1268 1304 Alternate 2 HP & Drive 1.61 1259 1.73 1317 1.77 1290 1.90 1348 1.95 1324 2.07 1382 2.14 1361 2.27 - 1.87 2.03 2.21 - Example RPM Selection Size (Tons) Model X Y Airflow Option Std. H. Static HP 1.5 2 Max BHP 1.73 2.30 Motor Sheave 1VM50 1VM50 Blower Sheave AK74 AK64 6 Turns Open N/A N/A 5 Turns Open 897 1039 4 Turns Open 945 1094 3 6 0.00 0.00 0.01 0.01 0.01 0.00 0.00 0.01 0.01 0.01 3 Turns Open 991 1150 2 Turns Open 1035 1207 1 Turn Open 1079 1256 Fully Closed 1126 1308 Example Additional Static Resistance Size (Tons) X 96 Model Y CFM Cooling Only 900 1000 1100 1200 1300 0.05 0.05 0.04 0.04 0.03 Economizer 4” Pleated Filter -0.05 -0.03 -0.02 0.00 0.01 0.01 0.02 0.03 0.04 0.05 Electric Heat kW 9 15 0.00 0.00 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.03 20 24 0.01 0.02 0.02 0.02 0.03 0.01 0.02 0.02 0.02 0.03 Johnson Controls Unitary Products 528150-YTG-T-0514 Altitude and Temperature Correction for CFM, Static Pressure and Power. use the indoor blower tables for high altitude applications, certain corrections are necessary. The information below should be used to assist in application of product when being applied at altitudes at or exceeding 1000 feet above sea level. A centrifugal fan is a "constant volume" device. This means that, if the rpm remains constant, the CFM delivered is the same regardless of the density of the air. However, since the air at high altitude is less dense, less static pressure will be generated and less power will be required than a similar application at sea level. Air density correction factors are shown in Table 14 and Figure 27. The air flow rates listed in the standard blower performance tables are based on standard air at sea level. As the altitude or temperature increases, the density of air decreases. In order to Altitude/Temperature Correction Factors Air Temp. 40 50 60 70 80 90 100 0 1.060 1.039 1.019 1.000 0.982 0.964 0.946 1000 1.022 1.002 0.982 0.964 0.947 0.929 0.912 2000 0.986 0.966 0.948 0.930 0.913 0.897 0.880 3000 0.950 0.931 0.913 0.896 0.880 0.864 0.848 4000 0.916 0.898 0.880 0.864 0.848 0.833 0.817 Altitude (Ft.) 5000 0.882 0.864 0.848 0.832 0.817 0.802 0.787 6000 0.849 0.832 0.816 0.801 0.787 0.772 0.758 7000 0.818 0.802 0.787 0.772 0.758 0.744 0.730 8000 0.788 0.772 0.757 0.743 0.730 0.716 0.703 9000 0.758 0.743 0.729 0.715 0.702 0.689 0.676 10000 0.729 0.715 0.701 0.688 0.676 0.663 0.651 1.100 1.050 Correction Factor 1.000 Sea Level 0.950 1000 ft 0.900 2000 ft 0.850 3000 ft 0.800 5000 ft 0.750 6000 ft 7000 ft 4000 ft 8000 ft 0.700 9000 ft 10000 ft 0.650 0.600 40 50 60 70 80 90 100 Air Temperature (ºF) The examples below will assist in determining the airflow performance of the product at altitude. blower tables to select the blower speed and the BHP requirement. Example 1: What are the corrected CFM, static pressure, and BHP at an elevation of 5,000 ft. if the blower performance data is 6,000 CFM, 1.5 IWC and 4.0 BHP? Solution: As in the example above, no temperature information is given so 70°F is assumed. Solution: At an elevation of 5,000 ft. the indoor blower will still deliver 6,000 CFM if the rpm is unchanged. However, Table 13 must be used to determine the static pressure and BHP. Since no temperature data is given, we will assume an air temperature of 70°F. Table 15 shows the correction factor to be 0.832. Corrected static pressure = 1.5 x 0.832 = 1.248 IWC Corrected BHP = 4.0 x 0.832 = 3.328 Example 2: A system, located at 5,000 feet of elevation, is to deliver 6,000 CFM at a static pressure of 1.5". Use the unit Johnson Controls Unitary Products The 1.5" static pressure given is at an elevation of 5,000 ft. The first step is to convert this static pressure to equivalent sea level conditions. Sea level static pressure = 1.5 / .832 = 1.80" Enter the blower table at 6000 sCFM and static pressure of 1.8". The rpm listed will be the same rpm needed at 5,000 ft. Suppose that the corresponding BHP listed in the table is 3.2. This value must be corrected for elevation. BHP at 5,000 ft. = 3.2 x .832 = 2.66 97 528150-YTG-T-0514 Indoor Blower Specifications Motor Airflow Size Model Option (Tons) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) ZH ZH ZH ZH ZH ZH ZH ZH ZJ ZJ ZJ ZJ ZJ ZJ ZJ ZJ ZR ZR ZR ZR ZR ZR ZR ZR Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static HP RPM Eff. SF 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 1-1/2 2 1-1/2 3 2 3 2 3 3 5 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 1-1/2 2 1-1/2 3 2 3 2 3 3 5 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 1-1/2 2 1-1/2 3 2 3 2 3 3 5 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 1725 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.87 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.87 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.87 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 Motor Sheave Datum Dia. Bore (in.) Frame (in.) 56 2.0 - 3.0 7/8 56 3.0 - 4.0 7/8 56 2.0 - 3.0 7/8 56 3.0 - 4.0 7/8 56 2.6 - 3.6 7/8 56 4.2 - 5.2 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 184T 4.3 - 5.3 1-1/8 56 2.0 - 3.0 7/8 56 3.0 - 4.0 7/8 56 2.0 - 3.0 7/8 56 3.0 - 4.0 7/8 56 2.6 - 3.6 7/8 56 4.2 - 5.2 7/8 56 2.6 - 3.6 7/8 56 3.6 - 4.6 7/8 56 2.6 - 3.6 7/8 56 3.6 - 4.6 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 184T 4.3 - 5.3 1-1/8 56 1.2 - 2.9 7/8 56 3.0 - 4.0 7/8 56 1.2 - 2.9 7/8 56 3.0 - 4.0 7/8 56 1.2 - 2.9 7/8 56 3.0 - 4.0 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 56 3.4 - 4.4 7/8 184T 4.3 - 5.3 1-1/8 Model 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 1VL40 1VM50 1VL40 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 1VP34 1VL44 1VP34 1VL44 1VP34 1VL44 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 Blower Sheave Datum Dia. Bore (in.) (in.) 6.5 1 6.5 1 5.2 1 5.2 1 5.7 1 7.0 1 7.0 1 6.0 1 7.0 1 5.7 1 9.0 1 7.0 1 8.0 1 7.0 1 7.0 1 6.7 1 6.5 1 6.5 1 5.2 1 5.2 1 5.7 1 7.0 1 7.0 1 7.0 1 6.5 1 6.5 1 8.5 1 7.0 1 8.0 1 7.0 1 7.0 1 6.7 1 5.7 1 5.5 1 5.7 1 5.5 1 5.7 1 5.5 1 7.0 1 6.0 1 7.0 1 5.7 1 8.5 1 7.0 1 8.0 1 7.0 1 7.0 1 6.7 1 Model AK69 AK69 AK56 AK56 AK61 AK74 AK74 AK64 AK74 AK61 AK94 AK74 AK84 AK74 AK74 BK77 AK69 AK69 AK56 AK56 AK61 AK74 AK74 AK74 AK69 AK69 AK89 AK74 AK84 AK74 AK74 BK77 AK61 AK59 AK61 AK59 AK61 AK59 AK74 AK64 AK74 AK61 AK89 AK74 AK84 AK74 AK74 BK77 Belt A47 A47 A47 A47 A47 A51 A49 A49 A49 A49 A56 A54 A56 A54 A54 BX55 A47 A47 A47 A47 A47 A51 A53 A54 A52 A54 A56 A54 A56 A54 A54 BX55 A47 A47 A47 A47 A47 A47 A49 A49 A49 A49 A56 A54 A56 A54 A54 BX55 Power Exhaust Specifications Model Voltage 2PE04703225 2PE04703246 2PE04703258 208/230-1-60 460-1-60 575-1-60 HP 3/4 3/4 3/4 Motor RPM1 1075 1075 1050 QTY 1 1 1 LRA 7.8 3.4 2.9 Motor FLA 5 2.2 1.5 MCA 6.3 2.8 1.9 Fuse Size 10 5 4 CFM @ 0.1 ESP 3800 3800 3800 1. Motors are multi-tapped and factory wired for high speed. 98 Johnson Controls Unitary Products 528150-YTG-T-0514 RPM Selection Size (Tons) 037 (3) Model ZH 049 (4) ZH 061 (5) ZH 078 (6.5) ZH 090 (7.5) ZH 102 (8.5) ZH 120 (10) ZH 150 (12.5) ZH 037 (3) ZJ 049 (4) ZJ 061 (5) ZJ 078 (6.5) ZJ 090 (7.5) ZJ 102 (8.5) ZJ 120 (10) ZJ 150 (12.5) ZJ 037 (3.0) ZR 049 (4.0) ZR 061 (5.0) ZR 078 (6.5) ZR 090 (7.5) ZR 102 (8.5) ZR 120 (10) ZR 150 (12.5) ZR Airflow Option Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. 1.5 1.5 1.5 1.5 1.5 2 1.5 2 1.5 3 2 3 2 3 3 5 1.5 1.5 1.5 1.5 1.5 2 1.5 2 1.5 3 2 3 2 3 3 5 1.5 Max BHP 1.5 1.5 1.5 1.5 1.5 2 1.73 2.30 1.73 3.45 2.30 3.45 2.30 3.45 3.45 5.75 1.5 1.5 1.5 1.5 1.5 2 1.73 2.30 1.73 3.45 2.30 3.45 2.30 3.45 3.45 5.75 1.5 H. Static 1.5 1.5 1VL44 AK59 N/A Std. 1.5 1.5 1VP34 AK61 N/A H. Static 1.5 1.5 1VL44 AK59 N/A Std. 1.5 1.5 1VP34 AK61 N/A HP Motor Sheave 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 1VM34 1VL44 1VM34 1VL44 1VL40 1VP56 1VL40 1VM50 1VL40 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 1VP34 Blower Sheave AK69 AK69 AK56 AK56 AK61 AK74 AK74 AK64 AK74 AK61 AK94 AK74 AK84 AK74 AK74 BK77 AK69 AK69 AK56 AK56 AK61 AK74 AK74 AK74 AK69 AK69 AK89 AK74 AK84 AK74 AK74 BK77 AK61 6 Turns Open N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 1052 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 1052 N/A 5 Turns Open 531 796 663 995 787 1035 887 1039 887 1088 690 887 776 887 887 1095 531 796 663 995 787 1035 641 887 690 955 731 887 776 887 887 1095 575 4 Turns Open 584 849 730 1062 847 1084 936 1094 936 1147 728 936 819 936 936 1136 584 849 730 1062 847 1084 690 936 743 1008 771 936 819 936 936 1136 636 3 Turns Open 637 902 796 1128 908 1134 986 1150 986 1205 767 986 863 986 986 1175 637 902 796 1128 908 1134 739 986 796 1062 812 986 863 986 986 1175 696 2 Turns Open 690 955 863 1194 968 1183 1035 1207 1035 1265 805 1035 906 1035 1035 1216 690 955 863 1194 968 1183 789 1035 849 1115 852 1035 906 1035 1035 1216 757 1 Turn Open 743 1008 929 1261 1029 1232 1084 1256 1084 1312 843 1084 949 1084 1084 1272 743 1008 929 1261 1029 1232 838 1084 902 1168 893 1084 949 1084 1084 1272 817 Fully Closed 796 1062 995 1327 1089 1281 1134 1308 1134 1365 882 1134 992 1134 1134 N/A 796 1062 995 1327 1089 1281 887 1134 955 1221 934 1134 992 1134 1134 N/A 878 878 941 1004 1066 1129 1192 575 636 696 757 817 878 878 941 1004 1066 1129 1192 575 636 696 757 817 878 H. Static 2 2 1VL44 AK59 N/A 878 941 1004 1066 1129 1192 Std. H. Static Std. H. Static Std. H. Static Std. H. Static Std. H. Static 1.5 2 1.5 3 2 3 2 3 3 5 1.73 2.30 1.73 3.45 2.30 3.45 2.30 3.45 3.45 5.75 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VM50 1VP56 AK74 AK64 AK74 AK61 AK89 AK74 AK84 AK74 AK74 BK77 N/A N/A N/A N/A N/A N/A N/A N/A N/A 1052 897 1039 897 1088 735 880 785 880 880 1095 945 1094 945 1147 775 928 821 928 928 1136 991 1150 991 1205 815 972 858 972 972 1175 1035 1207 1035 1265 851 1016 901 1016 1016 1216 1079 1256 1079 1312 889 1067 940 1067 1067 1272 1126 1308 1126 1365 930 1110 980 1110 1110 N/A Johnson Controls Unitary Products 99 528150-YTG-T-0514 Additional Static Resistance - ZH037 thru 061 Size (Tons) Model 037 (3) 049 (4) ZH 061 (5) ZH CFM Cooling Only1 Economizer2 3 4” Pleated Filter2 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 0.05 0.05 0.04 0.04 0.03 0.03 0.03 0.02 0.02 0.01 0.01 0.00 -0.01 -0.01 -0.01 -0.02 -0.02 -0.02 -0.03 -0.03 -0.04 -0.04 -0.05 -0.05 -0.03 -0.02 0.00 0.01 0.03 0.04 0.06 0.07 0.08 0.10 0.11 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.09 0.10 0.11 0.13 0.14 0.07 0.08 0.08 0.09 0.10 0.10 0.11 0.12 0.12 0.13 0.14 3 6 0.00 0.00 0.01 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.06 0.07 0.08 0.00 0.00 0.01 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.06 0.07 0.08 Electric Heat kW2 9 15 0.00 0.00 0.01 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.06 0.07 0.08 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.07 0.04 0.04 0.05 0.05 0.06 0.07 0.07 0.08 0.09 0.10 0.11 20 24 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.07 0.04 0.04 0.05 0.05 0.06 0.07 0.07 0.08 0.09 0.10 0.11 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.07 0.04 0.04 0.05 0.05 0.06 0.07 0.07 0.08 0.09 0.10 0.11 1. Add these values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Additional Static Resistance - ZJ/ZR037 thru 061 Size (Tons) Model 037 (3) ZJ/ZR 049 (4) 061 (5) ZJ/ZR CFM Cooling Only1 Economizer2 3 4” Pleated Filter2 900 1000 1100 1200 1300 1400 1500 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 0.05 0.05 0.04 0.04 0.03 0.03 0.03 -0.01 -0.01 -0.01 -0.01 -0.01 -0.01 -0.02 -0.02 -0.02 -0.03 -0.03 -0.04 -0.04 -0.05 -0.05 -0.03 -0.02 0.00 0.01 0.03 0.04 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 0.01 0.02 0.03 0.04 0.05 0.07 0.08 0.05 0.06 0.06 0.07 0.08 0.08 0.09 0.10 0.10 0.11 0.12 0.12 0.13 0.14 3 6 0.00 0.00 0.01 0.01 0.01 0.02 0.02 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.06 0.07 0.08 0.00 0.00 0.01 0.01 0.01 0.02 0.02 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.06 0.07 0.08 Electric Heat kW2 9 15 0.00 0.00 0.01 0.01 0.01 0.02 0.02 0.01 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.05 0.06 0.06 0.07 0.08 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.02 0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.07 0.07 0.08 0.09 0.10 0.11 20 24 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.02 0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.07 0.07 0.08 0.09 0.10 0.11 0.01 0.02 0.02 0.02 0.03 0.03 0.04 0.02 0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.07 0.07 0.08 0.09 0.10 0.11 1. Add these values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. 100 Johnson Controls Unitary Products 528150-YTG-T-0514 Additional Static Resistance - ZH/ZR078 thru 150 Size (Tons) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) Model CFM Cooling Only1 Economizer2 3 4” Filter2 ZHZR 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700 3900 4100 4300 4500 0.00 -0.01 -0.01 -0.02 -0.03 -0.04 -0.05 -0.06 -0.07 -0.08 -0.09 -0.09 -0.10 -0.11 0.07 0.09 0.11 0.13 0.16 0.18 0.20 0.22 0.24 0.27 0.29 0.31 0.30 0.35 1900 0.06 2100 0.07 2300 0.08 2500 0.09 2700 0.11 2900 0.12 3100 0.14 3300 0.16 3500 0.18 3700 0.20 3900 0.23 4100 0.25 4300 0.28 4500 0.30 4700 0.33 4900 0.36 5100 0.39 5300 0.42 5500 0.45 5700 0.48 5900 0.52 6100 0.56 6300 0.60 0.02 0.02 0.04 0.11 0.18 0.25 0.31 0.37 0.43 0.49 0.54 0.58 0.65 0.69 0.74 0.78 0.82 0.86 0.89 0.93 0.96 0.98 1.01 ZH/ZR Electric Heat kW2 24 36 09 18 0.10 0.11 0.12 0.14 0.15 0.16 0.18 0.19 0.20 0.21 0.23 0.24 0.25 0.26 0.05 0.06 0.07 0.08 0.09 0.10 0.12 0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.06 0.07 0.08 0.09 0.10 0.11 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.07 0.08 0.09 0.10 0.12 0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.28 0.30 0.08 0.09 0.10 0.11 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.29 0.31 0.10 0.11 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 54 0.12 0.05 0.06 0.07 0.08 0.10 0.13 0.06 0.07 0.08 0.09 0.11 0.14 0.07 0.08 0.09 0.10 0.13 0.16 0.08 0.09 0.10 0.11 0.14 0.17 0.09 0.10 0.12 0.13 0.16 0.19 0.10 0.11 0.13 0.14 0.18 0.20 0.12 0.13 0.15 0.16 0.20 0.22 0.13 0.14 0.17 0.18 0.22 0.25 0.15 0.16 0.19 0.20 0.24 0.27 0.17 0.18 0.21 0.22 0.26 0.29 0.19 0.20 0.23 0.24 0.28 0.32 0.21 0.22 0.25 0.26 0.31 0.35 0.23 0.24 0.28 0.29 0.34 0.38 0.25 0.26 0.30 0.31 0.37 0.41 0.28 0.29 0.33 0.34 0.40 0.44 0.30 0.31 0.35 0.37 0.43 0.47 0.33 0.34 0.38 0.40 0.46 0.51 0.35 0.37 0.41 0.43 0.49 0.56 0.38 0.40 0.44 0.46 0.53 0.58 0.41 0.43 0.47 0.49 0.56 0.62 0.44 0.46 0.50 0.53 0.59 0.67 0.47 0.49 0.53 0.56 0.62 0.71 0.50 0.53 0.56 0.59 0.65 1. Add these values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Johnson Controls Unitary Products 101 528150-YTG-T-0514 Additional Static Resistance - ZJ078-150 Size (Tons) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) Model CFM Cooling Only1 Economizer2,3 4” Filter2 ZJ 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700 3900 4100 4300 4500 4700 4900 5100 5300 5500 5700 5900 6100 6300 0.06 0.07 0.08 0.09 0.11 0.12 0.14 0.16 0.18 0.20 0.23 0.25 0.28 0.30 0.33 0.36 0.39 0.42 0.45 0.48 0.52 0.56 0.60 0.02 0.02 0.04 0.11 0.18 0.25 0.31 0.37 0.43 0.49 0.54 0.58 0.65 0.69 0.74 0.78 0.82 0.86 0.89 0.93 0.96 0.98 1.01 0.12 0.13 0.14 0.16 0.17 0.19 0.20 0.22 0.26 0.27 0.29 0.32 0.35 0.38 0.41 0.44 0.47 0.51 0.55 0.58 0.62 0.67 0.71 Electric Heat kW2 24 36 9 18 0.05 0.06 0.07 0.08 0.09 0.10 0.12 0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.28 0.30 0.33 0.35 0.38 0.41 0.44 0.47 0.50 0.06 0.07 0.08 0.09 0.10 0.11 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.29 0.31 0.34 0.37 0.40 0.43 0.46 0.49 0.53 0.07 0.08 0.09 0.10 0.12 0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.28 0.30 0.33 0.35 0.38 0.41 0.44 0.47 0.50 0.53 0.56 0.08 0.09 0.10 0.11 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.29 0.31 0.34 0.37 0.40 0.43 0.46 0.49 0.53 0.56 0.59 54 0.10 0.11 0.13 0.14 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.40 0.43 0.46 0.49 0.53 0.56 0.59 0.62 0.65 1. Add these values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. 102 Johnson Controls Unitary Products 528150-YTG-T-0514 Gas Heat Minimum Supply Air Size (Tons) Model 037 (3) ZH/ZJ/ZR 049 (4) ZH/ZJ/ZR 061 (5) ZH/ZJ/ZR 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR ZH/ZJ/ZR Supply Air (CFM) Heating Min Max 890 2220 915 2370 1130 1800 890 2220 915 2370 1290 2250 915 2370 1380 2570 1580 2630 1950 3250 1950 3250 2250 3750 2250 3750 2550 4250 2550 4250 3000 5000 3000 5000 3750 6250 3750 6250 Heat Size A05 / N05 A07 / N07 A09 / N09 A05 / N05 A07 / N07 A09 / N09 A07 / N07 A09 / N09 A13 / N13 10 15 10 15 10 15 15 20 15 20 Electric Heat Minimum Supply Air 3 thru 5 Tons Size (Tons) Model 037 (3) ZH/ZJ/ZR 049 (4) ZH/ZJ/ZR 061 (5) ZH/ZJ/ZR Voltage 208/230-3-60 460-3-60 600-3-60 208/230-3-60 460-3-60 600-3-60 208/230-3-60 460-3-60 600-3-60 Minimum Supply Air (CFM) Heater kW 9 15 1020 1020 960 960 960 960 1420 1420 1400 1400 1400 1400 1600 1600 1600 1600 1600 1600 3 960 980 - 6 960 960 1280 1400 1600 1600 - 9 1950 1950 1950 2250 2250 2250 2550 2550 2550 - Minimum Supply Air (CFM) Heater kW 18 24 36 1950 1950 1950 1950 1950 1950 1950 1950 1950 2250 2250 2250 2250 2250 2250 2250 2250 2250 2550 2550 2550 2550 2550 2550 2550 2550 2550 3000 3000 3000 3000 3000 3000 3000 3000 3000 3750 3750 3750 3750 3750 3750 3750 3750 3750 20 1420 1400 1400 1600 1600 1600 24 1600 1600 1600 6-1/2 thru 12-1/5 Tons Size (Tons) Model 078 (6.5) ZH/ZJ/ZR 090 (7.5) ZH/ZJ/ZR 102 (8.5) ZH/ZJ/ZR 120 (10) ZH/ZJ/ZR 150 (12.5) ZH/ZJ/ZR Johnson Controls Unitary Products Voltage 208/230-3-60 460-3-60 600-3-60 208/230-3-60 460-3-60 600-3-60 208/230-3-60 460-3-60 600-3-60 208/230-3-60 460-3-60 600-3-60 208/230-3-60 460-3-60 600-3-60 54 3500 3000 3500 4000 3750 3750 103 528150-YTG-T-0514 Airflow Performance ZH037-150 Side Duct Application ZH037 (3.0 Ton) Side Duct Air Flow (CFM) 900 1000 1100 1200 1300 1400 1500 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 560 582 601 620 638 655 673 0.29 0.29 0.30 0.32 0.35 0.39 0.43 Standard 1.5 HP & Drive 628 0.35 695 0.42 650 0.34 716 0.42 670 0.35 736 0.43 688 0.37 754 0.45 706 0.40 772 0.48 724 0.44 790 0.51 741 0.48 807 0.56 760 781 801 819 837 855 872 0.51 0.51 0.52 0.54 0.57 0.60 0.65 823 845 864 883 901 918 936 0.61 0.61 0.62 0.64 0.67 0.70 0.75 Hi Static 1.5 HP & Drive 886 0.72 949 0.82 908 0.71 970 0.82 927 0.72 990 0.83 946 0.74 1008 0.85 964 0.77 1026 0.88 981 0.81 1044 0.91 999 0.85 1061 0.96 1011 1032 1052 1070 1088 1106 1124 0.92 1073 1.01 1136 0.92 1095 1.01 1158 0.93 1114 1.02 1177 0.95 1133 1.04 1196 0.98 1151 1.06 1214 1.01 1168 1.10 1231 1.06 1186 1.15 1249 1.5 HP & Field Supplied Drive 1.09 1.08 1.09 1.11 1.14 1.18 1.22 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH049 (4.0 Ton) Side Duct Air Flow (CFM) 1200 1300 1400 1500 1600 1700 1800 1900 2000 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 620 0.32 638 0.35 655 0.39 673 0.43 691 0.48 709 0.54 728 0.60 747 0.67 766 0.75 688 706 724 741 759 777 796 815 834 0.37 0.40 0.44 0.48 0.54 0.59 0.66 0.73 0.80 754 772 790 807 825 843 862 881 901 Standard 1.5 HP & Drive 0.45 819 0.54 883 0.48 837 0.57 901 0.51 855 0.60 918 0.56 872 0.65 936 0.61 890 0.70 954 0.67 908 0.76 972 0.73 927 0.82 991 0.80 946 0.89 1010 0.87 966 0.96 1029 0.64 0.67 0.70 0.75 0.80 0.86 0.92 0.99 1.06 946 964 981 999 1017 1035 1053 1073 1092 0.74 0.77 0.81 0.85 0.90 0.96 1.03 1.09 1.17 1008 1026 1044 1061 1079 1097 1116 1135 1155 0.85 0.88 0.91 0.96 1.01 1.07 1.13 1.20 1.27 Hi Static 1.5 HP & Drive 1070 0.95 1133 1.04 1088 0.98 1151 1.06 1106 1.01 1168 1.10 1124 1.06 1186 1.15 1141 1.11 1204 1.20 1160 1.17 1222 1.26 1178 1.23 1241 1.32 1197 1.30 1260 1.39 1217 1.37 1279 1.46 1196 1214 1231 1249 1267 1285 1303 1323 - 1.11 1.14 1.18 1.22 1.27 1.33 1.39 1.46 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZH061 (5.0 Ton) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 1. 2. 3. 4. 104 659 675 691 707 724 741 759 778 797 817 838 0.35 0.38 0.42 0.47 0.53 0.59 0.65 0.73 0.81 0.90 1.00 719 735 751 767 784 801 819 838 857 877 898 0.46 0.50 0.54 0.58 0.64 0.70 0.77 0.84 0.92 1.01 1.11 780 796 812 829 846 863 881 900 919 939 960 Hi Static 2 HP & Drive Standard 1.5 HP & Drive 0.57 0.60 0.64 0.69 0.75 0.81 0.87 0.95 1.03 1.12 1.22 843 859 875 891 908 925 943 962 981 1002 1022 0.67 0.71 0.75 0.79 0.85 0.91 0.98 1.05 1.13 1.22 1.32 905 920 936 953 970 987 1005 1024 1043 1063 1084 0.77 0.81 0.85 0.90 0.95 1.01 1.08 1.15 1.23 1.32 1.42 964 980 996 1012 1029 1047 1065 1083 1103 1123 1144 0.87 0.91 0.95 0.99 1.05 1.11 1.18 1.25 1.33 1.42 1.52 1020 1036 1052 1069 1085 1103 1121 1139 1159 1179 1200 0.97 1.01 1.05 1.09 1.15 1.21 1.28 1.35 1.43 1.52 1.62 1071 1087 1103 1120 1137 1154 1172 1191 1210 1230 1251 1.07 1.11 1.15 1.20 1.25 1.31 1.38 1.45 1.53 1.62 1.72 1116 1132 1148 1165 1182 1199 1217 1236 1255 1275 1296 1.17 1154 1.21 1170 1.25 1186 1.30 1202 1.35 1219 1.41 1236 1.48 1254 1.56 1273 1.64 1292 1.73 1312 1.82 1333 FS4 1.28 1.32 1.36 1.41 1.46 1.52 1.59 1.66 1.74 1.83 1.93 Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078 (6.5 Ton) Side Duct Air Flow (CFM) 1800 2000 2200 2400 2600 2800 3000 3200 3400 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 751 776 804 835 869 906 945 987 1030 Field Supplied Drive 0.22 813 0.43 872 0.35 838 0.56 897 0.50 866 0.71 925 0.66 897 0.87 956 0.84 931 1.05 990 1.03 968 1.25 1027 1.25 1007 1.46 1066 1.48 1048 1.69 1107 1.73 1092 1.94 1151 0.62 0.75 0.90 1.06 1.24 1.43 1.65 1.88 2.12 929 954 982 1013 1047 1084 1123 1165 1208 0.78 0.92 1.06 1.22 1.40 1.60 1.81 2.04 2.29 Standard 1.5 HP & Drive 985 0.93 1040 1.07 1010 1.07 1064 1.20 1038 1.21 1092 1.35 1069 1.37 1124 1.51 1103 1.55 1158 1.69 1139 1.75 1194 1.89 1179 1.96 1234 2.10 1220 2.19 - 1095 1119 1147 1178 1212 1249 1288 - 1.20 1.33 1.48 1.64 1.82 2.02 2.23 - 1150 1175 1203 1234 1268 1304 - Hi Static 2 HP & Drive 1.33 1206 1.46 1265 1.46 1231 1.59 1289 1.61 1259 1.73 1317 1.77 1290 1.90 1348 1.95 1324 2.07 1382 2.14 1361 2.27 2 HP & Field Supplied Drive 1.59 1.72 1.87 2.03 2.21 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH090 (7.5 Ton) Side Duct Air Flow (CFM) 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 776 0.35 838 0.56 804 0.50 866 0.71 835 0.66 897 0.87 869 0.84 931 1.05 906 1.03 968 1.25 945 1.25 1007 1.46 987 1.48 1048 1.69 1030 1.73 1092 1.94 1076 1.99 1138 2.20 1124 2.27 1185 2.48 897 925 956 990 1027 1066 1107 1151 1197 1245 0.75 0.90 1.06 1.24 1.43 1.65 1.88 2.12 2.39 2.67 954 982 1013 1047 1084 1123 1165 1208 1254 1302 Standard 1.5 HP & Drive 0.92 1010 1.07 1064 1.06 1038 1.21 1092 1.22 1069 1.37 1124 1.40 1103 1.55 1158 1.60 1139 1.75 1194 1.81 1179 1.96 1234 2.04 1220 2.19 1275 2.29 1264 2.44 1319 2.56 1310 2.71 1364 2.84 1357 2.99 1412 1.20 1.35 1.51 1.69 1.89 2.10 2.33 2.58 2.84 3.12 1119 1147 1178 1212 1249 1288 1330 1374 1419 1467 Hi Static 3 HP & Drive 1.33 1175 1.46 1231 1.59 1289 1.48 1203 1.61 1259 1.73 1317 1.64 1234 1.77 1290 1.90 1348 1.82 1268 1.95 1324 2.07 1382 2.02 1304 2.14 1361 2.27 1419 2.23 1344 2.36 1400 2.48 1458 2.46 1385 2.59 1442 2.71 1500 2.71 1429 2.84 1485 2.96 1544 2.97 1475 3.10 1531 3.23 1589 3.25 1522 3.38 3 HP & Field Supplied Drive 1.72 1.87 2.03 2.21 2.40 2.62 2.85 3.10 3.36 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH102 (8.5 Ton) Side Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 628 0.56 678 0.76 648 0.67 698 0.87 666 0.80 717 1.00 684 0.95 735 1.15 702 1.11 753 1.31 721 1.28 772 1.48 742 1.47 793 1.67 765 1.67 815 1.86 789 1.87 840 2.07 730 750 768 786 804 824 844 867 891 Standard 2 HP & Drive 0.93 781 1.09 833 1.04 801 1.20 853 1.17 820 1.33 871 1.32 838 1.48 889 1.48 856 1.64 907 1.65 875 1.81 927 1.84 896 2.00 947 2.04 918 2.19 970 2.24 943 2.40 995 1.25 1.36 1.49 1.63 1.79 1.97 2.15 2.35 2.56 883 903 922 940 958 977 998 1020 1045 1.41 1.52 1.65 1.80 1.96 2.13 2.32 2.51 2.72 933 953 971 989 1007 1027 1047 1070 1094 Hi Static 3 HP & Drive 1.59 980 1.80 1025 2.05 1068 1.70 1000 1.91 1046 2.16 1088 1.83 1019 2.04 1064 2.29 1106 1.98 1037 2.19 1082 2.44 1124 2.14 1055 2.35 1100 2.60 1142 2.31 1074 2.52 1119 2.77 2.50 1095 2.71 1140 2.96 2.70 1117 2.91 2.90 3 HP & Field Supplied Drive 2.35 2.46 2.59 2.74 2.90 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 105 528150-YTG-T-0514 ZH120 (10 Ton) Side Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 675 0.53 726 0.74 686 0.63 738 0.84 699 0.75 750 0.96 713 0.88 764 1.09 728 1.02 779 1.23 745 1.18 796 1.39 763 1.36 815 1.57 783 1.55 835 1.76 805 1.77 856 1.98 828 2.00 879 2.21 852 2.25 904 2.46 879 2.52 930 2.73 906 2.81 958 3.02 776 787 800 814 829 846 864 884 906 929 953 980 1007 0.94 1.04 1.16 1.28 1.43 1.59 1.76 1.96 2.17 2.41 2.66 2.93 3.22 824 835 847 861 877 893 912 932 953 976 1001 1027 1055 Standard 2 HP & Drive 1.12 870 1.30 914 1.23 881 1.41 925 1.34 893 1.52 938 1.47 907 1.65 952 1.61 923 1.79 967 1.77 939 1.95 984 1.95 958 2.13 1002 2.15 978 2.33 1022 2.36 999 2.54 1044 2.59 1022 2.77 1067 2.85 1047 3.03 1092 3.12 1073 3.30 3.41 - 1.48 1.58 1.70 1.83 1.97 2.13 2.31 2.50 2.72 2.95 3.20 - 957 969 981 995 1010 1027 1046 1066 1087 1110 1135 - Hi Static 3 HP & Drive 1.65 1000 1.82 1041 1.99 1082 1.76 1011 1.93 1052 2.10 1093 1.87 1024 2.04 1065 2.21 1106 2.00 1037 2.17 1079 2.34 1119 2.14 1053 2.31 1094 2.48 1135 2.30 1069 2.47 1111 2.64 1152 2.48 1088 2.65 1129 2.82 1170 2.67 1108 2.84 1149 3.02 1190 2.89 1129 3.06 1171 3.23 1211 3.12 1152 3.29 3.37 3 HP & Field Supplied Drive 2.17 2.27 2.39 2.52 2.66 2.82 3.00 3.19 3.41 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH150 (12.5 Ton) Side Duct Air Flow (CFM) 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 713 728 745 763 783 805 828 852 879 906 936 966 999 1032 1067 1103 0.88 1.02 1.18 1.36 1.55 1.77 2.00 2.25 2.52 2.81 3.12 3.45 3.80 4.16 4.54 4.94 Field Supplied Drive 764 1.09 814 1.28 779 1.23 829 1.43 796 1.39 846 1.59 815 1.57 864 1.76 835 1.76 884 1.96 856 1.98 906 2.17 879 2.21 929 2.41 904 2.46 953 2.66 930 2.73 980 2.93 958 3.02 1007 3.22 987 3.33 1037 3.53 1018 3.66 1067 3.86 1050 4.01 1100 4.20 1084 4.37 1133 4.57 1119 4.75 1168 4.95 1155 5.15 1204 5.34 Hi Static 5 HP & Drive 861 877 893 912 932 953 976 1001 1027 1055 1084 1115 1147 1181 1216 1252 1.47 1.61 1.77 1.95 2.15 2.36 2.59 2.85 3.12 3.41 3.72 4.05 4.39 4.75 5.13 5.53 907 923 939 958 978 999 1022 1047 1073 1101 1130 1161 1193 1227 1262 1298 1.65 1.79 1.95 2.13 2.33 2.54 2.77 3.03 3.30 3.59 3.90 4.23 4.57 4.93 5.31 5.71 952 967 984 1002 1022 1044 1067 1092 1118 1146 1175 1206 1238 1271 1306 - 1.83 1.97 2.13 2.31 2.50 2.72 2.95 3.20 3.47 3.76 4.07 4.40 4.75 5.11 5.49 - Standard 3 HP & Drive 995 2.00 1037 2.17 1010 2.14 1053 2.31 1027 2.30 1069 2.47 1046 2.48 1088 2.65 1066 2.67 1108 2.84 1087 2.89 1129 3.06 1110 3.12 1152 3.29 1135 3.37 1177 3.54 1161 3.65 1203 3.82 1189 3.94 1231 4.11 1218 4.24 1260 4.42 1249 4.57 1291 4.74 1281 4.92 1323 5.09 1315 5.28 1357 5.45 1350 5.66 5 HP & Field Supplied Drive 1079 1094 1111 1129 1149 1171 1194 1219 1245 1273 1302 1333 1365 1398 - 2.34 2.48 2.64 2.82 3.02 3.23 3.46 3.72 3.99 4.28 4.59 4.91 5.26 5.62 - 1119 1135 1152 1170 1190 1211 1235 1259 1285 1313 1343 1373 1405 - 2.52 2.66 2.82 3.00 3.19 3.41 3.64 3.89 4.16 4.45 4.76 5.09 5.44 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 106 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH037-150 Bottom Duct Application ZH037 (3.0 Ton) Bottom Duct Air Flow (CFM) 900 1000 1100 1200 1300 1400 1500 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 605 621 637 651 666 681 697 Standard 1.5 HP & Drive 0.23 671 0.33 738 0.25 688 0.34 754 0.27 703 0.36 769 0.30 717 0.39 784 0.33 732 0.43 799 0.37 747 0.47 814 0.42 763 0.51 830 0.42 0.44 0.46 0.49 0.52 0.56 0.61 804 820 835 850 865 880 896 0.52 0.53 0.56 0.58 0.62 0.66 0.71 869 885 900 915 930 945 961 Hi Static 1.5 HP & Drive 0.62 933 0.71 995 0.63 949 0.72 1011 0.65 964 0.74 1026 0.68 979 0.77 1041 0.71 994 0.81 1056 0.75 1009 0.85 1071 0.80 1025 0.90 1087 0.80 0.82 0.84 0.87 0.90 0.94 0.99 1054 0.89 1111 0.98 1071 0.91 1127 1.00 1086 0.93 1142 1.02 1100 0.96 1157 1.05 1115 0.99 1172 1.08 1130 1.03 1187 1.12 1146 1.08 1203 1.17 1.5 HP & Field Supplied Drive 1164 1180 1195 1210 1225 1240 1256 1.07 1.09 1.11 1.13 1.17 1.21 1.26 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH049 (4.0 Ton) Bottom Duct Air Flow (CFM) 1200 1300 1400 1500 1600 1700 1800 1900 2000 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 651 0.30 666 0.33 681 0.37 697 0.42 714 0.47 732 0.53 751 0.60 771 0.68 793 0.75 717 732 747 763 780 798 817 837 859 0.39 0.43 0.47 0.51 0.57 0.63 0.70 0.77 0.85 784 799 814 830 846 864 883 904 925 Standard 1.5 HP & Drive 0.49 850 0.58 915 0.52 865 0.62 930 0.56 880 0.66 945 0.61 896 0.71 961 0.66 913 0.76 978 0.73 930 0.82 996 0.79 950 0.89 1015 0.87 970 0.96 1035 0.95 991 1.04 1056 0.68 0.71 0.75 0.80 0.86 0.92 0.98 1.06 1.14 979 994 1009 1025 1042 1059 1079 1099 1120 0.77 0.81 0.85 0.90 0.95 1.01 1.08 1.15 1.23 1041 1056 1071 1087 1103 1121 1140 1161 1182 0.87 0.90 0.94 0.99 1.04 1.10 1.17 1.25 1.32 Hi Static 1.5 HP & Drive 1100 0.96 1157 1.05 1115 0.99 1172 1.08 1130 1.03 1187 1.12 1146 1.08 1203 1.17 1163 1.14 1220 1.22 1181 1.20 1237 1.29 1200 1.26 1257 1.35 1220 1.34 1277 1.43 1242 1.42 1298 1.51 1210 1225 1240 1256 1273 1291 1310 - 1.13 1.17 1.21 1.26 1.31 1.37 1.44 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZH061 (5.0 Ton) Bottom Duct Air Flow (CFM) 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive 673 0.47 736 0.54 797 693 0.49 756 0.57 817 713 0.53 777 0.60 837 734 0.57 797 0.65 858 755 0.62 819 0.70 879 776 0.69 840 0.76 900 798 0.76 861 0.84 921 819 0.84 882 0.92 943 840 0.93 903 1.01 964 861 1.03 925 1.11 985 882 1.14 946 1.22 1006 0.63 0.65 0.69 0.73 0.79 0.85 0.92 1.00 1.10 1.20 1.30 855 874 895 916 937 958 979 1001 1022 1043 1064 Standard 1.5 HP & Drive 0.72 910 0.82 964 0.75 930 0.85 984 0.78 951 0.88 1004 0.83 971 0.92 1025 0.88 992 0.98 1046 0.94 1014 1.04 1067 1.02 1035 1.11 1089 1.10 1056 1.20 1110 1.19 1077 1.29 1131 1.29 1099 1.39 1152 1.40 1120 1.50 1173 0.92 0.95 0.98 1.03 1.08 1.14 1.22 1.30 1.39 1.49 1.60 1016 1036 1057 1077 1098 1120 1141 1162 1183 1204 1226 1.03 1.06 1.09 1.14 1.19 1.25 1.32 1.41 1.50 1.60 1.71 1067 1087 1107 1128 1149 1171 1192 1213 1234 1255 1276 Hi Static 2 HP & Drive 1.14 1117 1.25 1166 1.17 1137 1.28 1186 1.20 1157 1.31 1207 1.25 1178 1.36 1228 1.30 1199 1.41 1249 1.36 1221 1.47 1270 1.44 1242 1.55 1291 1.52 1263 1.63 1312 1.61 1284 1.72 1334 1.71 1305 1.82 1355 1.82 1326 1.93 1376 3 HP & Field Supplied Drive 1.36 1.39 1.42 1.47 1.52 1.59 1.66 1.74 1.83 1.93 2.04 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 107 528150-YTG-T-0514 ZH078 (6.5 Ton) Bottom Duct Air Flow (CFM) 1800 2000 2200 2400 2600 2800 3000 3200 3400 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 775 0.31 850 0.53 803 0.45 878 0.67 838 0.60 913 0.82 878 0.78 953 1.00 923 0.98 997 1.20 971 1.20 1046 1.42 1023 1.44 1097 1.66 1077 1.71 1151 1.93 1133 1.99 1208 2.21 924 952 986 1027 1071 1119 1171 1225 - Standard 1.5 HP & Drive 0.72 998 0.89 1072 0.86 1026 1.03 1100 1.01 1060 1.19 1134 1.19 1100 1.36 1174 1.39 1145 1.56 1219 1.61 1193 1.78 1267 1.85 1245 2.03 1319 2.12 1299 2.29 - 1.05 1.19 1.34 1.52 1.72 1.94 2.18 - 1147 1175 1210 1250 1294 1343 - Hi Static 2 HP & Drive 1.20 1224 1.35 1303 1.51 1.34 1252 1.49 1331 1.65 1.49 1286 1.65 1365 1.81 1.67 1327 1.82 1405 1.98 1.87 1371 2.02 1450 2.18 2.09 1419 2.24 2 HP & Field Supplied Drive 1384 1412 1447 1487 - 1.69 1.83 1.98 2.16 - 1469 1497 1532 - 1.89 2.03 2.18 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH090 (7.5 Ton) Bottom Duct Air Flow (CFM) 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 803 0.45 878 0.67 838 0.60 913 0.82 878 0.78 953 1.00 923 0.98 997 1.20 971 1.20 1046 1.42 1023 1.44 1097 1.66 1077 1.71 1151 1.93 1133 1.99 1208 2.21 1192 2.30 1267 2.52 1253 2.63 1327 2.85 952 986 1027 1071 1119 1171 1225 1282 1341 1401 Standard 1.5 HP & Drive 0.86 1026 1.03 1100 1.01 1060 1.19 1134 1.19 1100 1.36 1174 1.39 1145 1.56 1219 1.61 1193 1.78 1267 1.85 1245 2.03 1319 2.12 1299 2.29 1373 2.41 1356 2.58 1430 2.71 1414 2.88 1489 3.04 1475 3.21 1549 1.19 1.34 1.52 1.72 1.94 2.18 2.45 2.73 3.04 3.37 Hi Static 3 HP & Drive 1175 1.34 1252 1.49 1331 1210 1.49 1286 1.65 1365 1250 1.67 1327 1.82 1405 1294 1.87 1371 2.02 1450 1343 2.09 1419 2.24 1498 1394 2.33 1471 2.49 1550 1448 2.60 1525 2.75 1604 1505 2.88 1582 3.04 1661 1564 3.19 1641 3.34 3 HP & Field Supplied Drive 1.65 1.81 1.98 2.18 2.40 2.65 2.91 3.20 - 1412 1447 1487 1532 1580 1632 1686 1742 - 1.83 1.98 2.16 2.36 2.58 2.82 3.09 3.37 - 1497 1532 1572 1617 1665 1717 1771 - 2.03 2.18 2.36 2.56 2.78 3.02 3.29 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH102 (8.5 Ton) Bottom Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 1. 2. 3. 4. 108 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 674 0.71 689 0.86 707 1.01 728 1.17 751 1.34 776 1.53 804 1.74 835 1.97 867 2.21 731 746 764 785 808 833 861 892 924 Standard 2 HP & Drive 0.88 786 1.05 838 1.02 801 1.20 854 1.17 819 1.35 872 1.33 840 1.51 892 1.51 863 1.68 915 1.70 888 1.87 941 1.90 916 2.08 969 2.13 947 2.31 999 2.37 979 2.55 1032 1.24 1.38 1.53 1.69 1.87 2.06 2.26 2.49 2.73 887 903 921 941 964 990 1018 1048 1081 1.42 1.56 1.71 1.87 2.05 2.24 2.44 2.67 2.91 933 948 966 987 1010 1035 1063 1094 1127 1.59 1.73 1.88 2.04 2.22 2.41 2.61 2.84 3.08 Hi Static 3 HP & Drive 974 1.74 1010 1.87 1040 1.97 989 1.88 1025 2.01 1056 2.11 1007 2.03 1043 2.16 1074 2.26 1028 2.20 1064 2.33 1094 2.42 1051 2.37 1087 2.50 1117 2.60 1076 2.56 1112 2.69 1142 2.79 1104 2.77 1140 2.90 1170 2.99 1135 2.99 3 HP & Field Supplied Drive 1064 1080 1098 1118 1141 1167 - 2.03 2.17 2.32 2.48 2.66 2.85 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. Johnson Controls Unitary Products 528150-YTG-T-0514 ZH120 (10 Ton) Bottom Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 722 0.83 744 0.97 769 1.13 797 1.32 828 1.52 861 1.75 897 2.00 935 2.27 976 2.57 1019 2.88 1065 3.22 Standard 2 HP & Drive 776 798 823 851 882 915 951 989 1030 1073 1119 0.97 1.12 1.28 1.46 1.67 1.90 2.15 2.42 2.72 3.03 3.36 828 850 875 903 934 967 1002 1041 1082 1125 - 1.11 1.26 1.42 1.60 1.81 2.04 2.29 2.56 2.86 3.17 - 878 900 925 953 983 1017 1052 1091 1132 1175 - 1.25 1.39 1.55 1.74 1.94 2.17 2.42 2.69 2.99 3.30 - 926 949 974 1001 1032 1065 1101 1139 1180 1223 - Hi Static 3 HP & Drive 1.37 973 1.50 1018 1.52 995 1.64 1041 1.68 1020 1.80 1066 1.86 1048 1.99 1093 2.07 1078 2.19 1124 2.30 1112 2.42 1157 2.55 1147 2.67 1193 2.82 1186 2.95 1231 3.12 1227 3.24 1272 3.43 3 HP & Field Supplied Drive 1.62 1.76 1.92 2.11 2.32 2.54 2.80 3.07 3.36 - 1063 1085 1110 1138 1168 1201 1237 1275 - 1.74 1.88 2.05 2.23 2.44 2.67 2.92 3.19 - 1106 1128 1153 1181 1212 1245 1280 1319 - 1.86 2.00 2.17 2.35 2.56 2.79 3.04 3.31 - 1149 1171 1196 1224 1254 1287 1323 1362 - 1.99 2.13 2.29 2.48 2.68 2.91 3.16 3.43 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZH150 (12.5 Ton) Bottom Duct Air Flow (CFM) 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 797 1.32 851 1.46 828 1.52 882 1.67 861 1.75 915 1.90 897 2.00 951 2.15 935 2.27 989 2.42 976 2.57 1030 2.72 1019 2.88 1073 3.03 1065 3.22 1119 3.36 1113 3.57 1167 3.72 1163 3.94 1217 4.09 1216 4.34 1270 4.48 1270 4.75 1324 4.89 1327 5.17 1381 5.32 1385 5.62 - 903 934 967 1002 1041 1082 1125 1171 1219 1269 1321 1376 1433 - 1.60 1.81 2.04 2.29 2.56 2.86 3.17 3.50 3.86 4.23 4.62 5.03 5.46 - 953 983 1017 1052 1091 1132 1175 1221 1269 1319 1371 1426 1483 - Standard 3 HP & Drive 1.74 1001 1.86 1048 1.99 1.94 1032 2.07 1078 2.19 2.17 1065 2.30 1112 2.42 2.42 1101 2.55 1147 2.67 2.69 1139 2.82 1186 2.95 2.99 1180 3.12 1227 3.24 3.30 1223 3.43 1270 3.55 3.64 1269 3.76 1316 3.89 3.99 1317 4.12 1364 4.24 4.36 1367 4.49 1414 4.62 4.76 1420 4.88 1466 5.01 5.17 1474 5.29 1521 5.42 5.59 1531 5.72 5 HP & Field Supplied Drive 1093 1124 1157 1193 1231 1272 1315 1361 1409 1459 1512 1566 - 2.11 2.32 2.54 2.80 3.07 3.36 3.67 4.01 4.36 4.74 5.13 5.54 - 1138 1168 1201 1237 1275 1316 1360 1405 1453 1504 1556 1611 - Hi Static 5 HP & Drive 2.23 1181 2.35 1224 2.44 1212 2.56 1254 2.67 1245 2.79 1287 2.92 1280 3.04 1323 3.19 1319 3.31 1362 3.48 1360 3.60 1402 3.80 1403 3.92 1446 4.13 1449 4.25 1491 4.48 1497 4.61 1540 4.86 1547 4.98 1590 5.25 1600 5.37 1642 5.66 - 2.48 2.68 2.91 3.16 3.43 3.73 4.04 4.38 4.73 5.10 5.50 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 109 528150-YTG-T-0514 ZJ037-150 Side Duct Application ZJ037 (3.0 Ton) Side Duct Air Flow (CFM) 900 1000 1100 1200 1300 1400 1500 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 560 582 601 620 638 655 673 0.29 0.29 0.30 0.32 0.35 0.39 0.43 Standard 1.5 HP & Drive 628 0.35 695 0.42 650 0.34 716 0.42 670 0.35 736 0.43 688 0.37 754 0.45 706 0.40 772 0.48 724 0.44 790 0.51 741 0.48 807 0.56 760 781 801 819 837 855 872 0.51 0.51 0.52 0.54 0.57 0.60 0.65 823 845 864 883 901 918 936 0.61 0.61 0.62 0.64 0.67 0.70 0.75 Hi Static 1.5 HP & Drive 886 0.72 949 0.82 908 0.71 970 0.82 927 0.72 990 0.83 946 0.74 1008 0.85 964 0.77 1026 0.88 981 0.81 1044 0.91 999 0.85 1061 0.96 1011 1032 1052 1070 1088 1106 1124 0.92 1073 1.01 1136 0.92 1095 1.01 1158 0.93 1114 1.02 1177 0.95 1133 1.04 1196 0.98 1151 1.06 1214 1.01 1168 1.10 1231 1.06 1186 1.15 1249 1.5 HP & Field Supplied Drive 1.09 1.08 1.09 1.11 1.14 1.18 1.22 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZJ049 (4.0 Ton) Side Duct Air Flow (CFM) 1200 1300 1400 1500 1600 1700 1800 1900 2000 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 608 0.25 623 0.28 637 0.31 650 0.35 664 0.39 678 0.44 693 0.50 708 0.56 725 0.62 677 692 706 720 734 748 763 778 794 0.34 0.37 0.40 0.44 0.49 0.54 0.59 0.65 0.72 744 758 772 786 800 814 829 844 860 0.44 0.47 0.50 0.54 0.58 0.63 0.69 0.75 0.82 Standard 1.5 HP & Drive 807 0.54 868 0.64 822 0.57 883 0.67 836 0.60 897 0.70 849 0.64 911 0.74 863 0.68 924 0.78 877 0.73 938 0.83 892 0.79 953 0.89 907 0.85 968 0.95 924 0.92 985 1.02 927 942 956 970 984 998 1013 1028 1044 0.74 0.77 0.80 0.84 0.88 0.93 0.99 1.05 1.12 986 1001 1015 1028 1042 1056 1071 1086 1102 0.84 0.86 0.90 0.93 0.98 1.03 1.08 1.15 1.21 1043 1058 1072 1086 1100 1114 1129 1144 1160 Hi Static 1.5 HP & Drive 0.93 1101 1.02 1160 0.96 1116 1.04 1175 0.99 1130 1.08 1189 1.03 1144 1.12 1202 1.07 1158 1.16 1216 1.12 1172 1.21 1230 1.18 1186 1.26 1245 1.24 1202 1.33 1260 1.30 1218 1.39 1277 1.10 1.13 1.16 1.20 1.24 1.29 1.35 1.41 1.47 Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive ZJ061 (5.0 Ton) Side Duct Air Flow (CFM) 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 1. 2. 3. 4. 110 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 659 675 691 707 724 741 759 778 797 817 838 1.5 HP & Field Suplied Drive 0.35 719 0.46 780 0.38 735 0.50 796 0.42 751 0.54 812 0.47 767 0.58 829 0.53 784 0.64 846 0.59 801 0.70 863 0.65 819 0.77 881 0.73 838 0.84 900 0.81 857 0.92 919 0.90 877 1.01 939 1.00 898 1.11 960 0.57 0.60 0.64 0.69 0.75 0.81 0.87 0.95 1.03 1.12 1.22 843 859 875 891 908 925 943 962 981 1002 1022 0.67 0.71 0.75 0.79 0.85 0.91 0.98 1.05 1.13 1.22 1.32 905 920 936 953 970 987 1005 1024 1043 1063 1084 Standard 1.5 HP & Drive 0.77 964 0.87 1020 0.81 980 0.91 1036 0.85 996 0.95 1052 0.90 1012 0.99 1069 0.95 1029 1.05 1085 1.01 1047 1.11 1103 1.08 1065 1.18 1121 1.15 1083 1.25 1139 1.23 1103 1.33 1159 1.32 1123 1.42 1179 1.42 1144 1.52 1200 0.97 1.01 1.05 1.09 1.15 1.21 1.28 1.35 1.43 1.52 1.62 1071 1087 1103 1120 1137 1154 1172 1191 1210 1230 1251 1.07 1.11 1.15 1.20 1.25 1.31 1.38 1.45 1.53 1.62 1.72 Hi Static 2 HP & Drive 1116 1.17 1154 1.28 1132 1.21 1170 1.32 1148 1.25 1186 1.36 1165 1.30 1202 1.41 1182 1.35 1219 1.46 1199 1.41 1236 1.52 1217 1.48 1254 1.59 1236 1.56 1273 1.66 1255 1.64 1292 1.74 1275 1.73 1312 1.83 1296 1.82 1333 1.93 FS4 Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078 (6.5 Ton) Side Duct Air Flow (CFM) 1800 2000 2200 2400 2600 2800 3000 3200 3400 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 514 529 544 559 574 590 607 624 641 FS4 0.15 586 0.23 601 0.33 616 0.43 631 0.54 646 0.67 662 0.80 679 0.95 695 1.10 713 0.33 0.41 0.51 0.61 0.72 0.85 0.98 1.13 1.28 657 672 687 702 717 733 750 766 784 0.52 0.60 0.69 0.80 0.91 1.03 1.17 1.31 1.47 727 741 756 771 787 802 819 836 853 Standard 1.5 HP & Drive 0.71 794 0.89 857 0.79 808 0.97 872 0.88 823 1.07 886 0.98 838 1.17 902 1.10 853 1.28 917 1.22 869 1.41 933 1.36 886 1.54 949 1.50 903 1.69 966 1.66 920 1.84 984 1.07 1.15 1.24 1.35 1.46 1.59 1.72 1.86 2.02 917 931 946 961 977 993 1009 1026 1043 1.23 1.31 1.41 1.51 1.62 1.75 1.88 2.03 2.18 972 986 1001 1016 1032 1047 1064 1081 1098 Hi Static 2 HP & Drive 1.38 1021 1.50 1064 1.46 1036 1.58 1079 1.55 1051 1.67 1094 1.65 1066 1.78 1109 1.77 1081 1.89 1124 1.89 1097 2.02 1140 2.03 1113 2.15 1157 2.17 1130 2.29 2.33 FS4 1.59 1.67 1.77 1.87 1.98 2.11 2.24 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZJ090 (7.5 Ton) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 1. 2. 3. 4. 619 631 642 652 663 675 688 703 718 0.07 0.16 0.27 0.39 0.53 0.68 0.84 1.03 1.23 656 670 682 692 703 714 726 739 753 769 0.24 0.32 0.41 0.52 0.64 0.77 0.92 1.09 1.28 1.47 711 724 736 747 757 768 780 793 807 823 0.48 0.57 0.66 0.76 0.88 1.02 1.17 1.34 1.52 1.72 768 781 793 804 814 825 837 850 864 880 Standard 1.5 HP & Drive 0.73 826 0.96 886 0.81 840 1.04 899 0.90 852 1.14 911 1.01 862 1.24 922 1.13 873 1.36 932 1.26 884 1.50 943 1.41 896 1.65 955 1.58 909 1.82 968 1.76 923 2.00 983 1.96 939 2.20 998 1.19 1.27 1.36 1.47 1.59 1.73 1.88 2.04 2.23 2.43 945 959 970 981 992 1003 1014 1027 1042 1058 1.41 1.49 1.58 1.69 1.81 1.94 2.09 2.26 2.44 2.64 1003 1016 1028 1039 1049 1060 1072 1085 1100 1115 Hi Static 3 HP & Drive 1.61 1058 1.79 1110 1.69 1072 1.87 1124 1.78 1084 1.97 1136 1.89 1094 2.07 1146 2.01 1105 2.19 1157 2.14 1116 2.33 1168 2.29 1128 2.48 1180 2.46 1141 2.65 1193 2.64 1155 2.83 2.84 1171 3.03 - 1.95 2.04 2.13 2.24 2.36 2.49 2.64 2.81 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZJ102 (8.5 Ton) Side Duct Air Flow (CFM) 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 654 0.32 706 0.53 664 0.43 716 0.64 675 0.53 726 0.74 686 0.63 738 0.84 699 0.75 750 0.96 713 0.88 764 1.09 728 1.02 779 1.23 745 1.18 796 1.39 763 1.36 815 1.57 783 1.55 835 1.76 805 1.77 856 1.98 755 765 776 787 800 814 829 846 864 884 906 0.73 0.83 0.94 1.04 1.16 1.28 1.43 1.59 1.76 1.96 2.17 Standard 2 HP & Drive 803 0.92 849 1.10 813 1.02 859 1.20 824 1.12 870 1.30 835 1.23 881 1.41 847 1.34 893 1.52 861 1.47 907 1.65 877 1.61 923 1.79 893 1.77 939 1.95 912 1.95 958 2.13 932 2.15 978 2.33 953 2.36 999 2.54 893 904 914 925 938 952 967 984 1002 1022 1044 1.27 1.38 1.48 1.58 1.70 1.83 1.97 2.13 2.31 2.50 2.72 937 947 957 969 981 995 1010 1027 1046 1066 1087 1.44 1.55 1.65 1.76 1.87 2.00 2.14 2.30 2.48 2.67 2.89 Hi Static 3 HP & Drive 979 1.62 1020 1.79 1061 1.96 989 1.72 1030 1.89 1071 2.07 1000 1.82 1041 1.99 1082 2.17 1011 1.93 1052 2.10 1093 2.27 1024 2.04 1065 2.21 1106 2.39 1037 2.17 1079 2.34 1119 2.52 1053 2.31 1094 2.48 1135 2.66 1069 2.47 1111 2.64 1152 2.82 1088 2.65 1129 2.82 1170 3.00 1108 2.84 1149 3.02 1190 3.19 1129 3.06 1171 3.23 1211 3.41 3 HP & Field Supplied Drive 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 111 528150-YTG-T-0514 ZJ120 (10 Ton) Side Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 675 0.53 726 0.74 686 0.63 738 0.84 699 0.75 750 0.96 713 0.88 764 1.09 728 1.02 779 1.23 745 1.18 796 1.39 763 1.36 815 1.57 783 1.55 835 1.76 805 1.77 856 1.98 828 2.00 879 2.21 852 2.25 904 2.46 879 2.52 930 2.73 906 2.81 958 3.02 776 787 800 814 829 846 864 884 906 929 953 980 1007 0.94 1.04 1.16 1.28 1.43 1.59 1.76 1.96 2.17 2.41 2.66 2.93 3.22 824 835 847 861 877 893 912 932 953 976 1001 1027 1055 Standard 2 HP & Drive 1.12 870 1.30 914 1.23 881 1.41 925 1.34 893 1.52 938 1.47 907 1.65 952 1.61 923 1.79 967 1.77 939 1.95 984 1.95 958 2.13 1002 2.15 978 2.33 1022 2.36 999 2.54 1044 2.59 1022 2.77 1067 2.85 1047 3.03 1092 3.12 1073 3.30 3.41 - 1.48 1.58 1.70 1.83 1.97 2.13 2.31 2.50 2.72 2.95 3.20 - 957 969 981 995 1010 1027 1046 1066 1087 1110 1135 - Hi Static 3 HP & Drive 1.65 1000 1.82 1041 1.99 1082 1.76 1011 1.93 1052 2.10 1093 1.87 1024 2.04 1065 2.21 1106 2.00 1037 2.17 1079 2.34 1119 2.14 1053 2.31 1094 2.48 1135 2.30 1069 2.47 1111 2.64 1152 2.48 1088 2.65 1129 2.82 1170 2.67 1108 2.84 1149 3.02 1190 2.89 1129 3.06 1171 3.23 1211 3.12 1152 3.29 3.37 3 HP & Field Supplied Drive 2.17 2.27 2.39 2.52 2.66 2.82 3.00 3.19 3.41 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZJ150 (12.5 Ton) Side Duct Air Flow (CFM) 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 713 728 745 763 783 805 828 852 879 906 936 966 999 1032 1067 1103 0.88 1.02 1.18 1.36 1.55 1.77 2.00 2.25 2.52 2.81 3.12 3.45 3.80 4.16 4.54 4.94 Field Supplied Drive 764 1.09 814 1.28 779 1.23 829 1.43 796 1.39 846 1.59 815 1.57 864 1.76 835 1.76 884 1.96 856 1.98 906 2.17 879 2.21 929 2.41 904 2.46 953 2.66 930 2.73 980 2.93 958 3.02 1007 3.22 987 3.33 1037 3.53 1018 3.66 1067 3.86 1050 4.01 1100 4.20 1084 4.37 1133 4.57 1119 4.75 1168 4.95 1155 5.15 1204 5.34 Hi Static 5 HP & Drive 861 877 893 912 932 953 976 1001 1027 1055 1084 1115 1147 1181 1216 1252 1.47 1.61 1.77 1.95 2.15 2.36 2.59 2.85 3.12 3.41 3.72 4.05 4.39 4.75 5.13 5.53 907 923 939 958 978 999 1022 1047 1073 1101 1130 1161 1193 1227 1262 1298 1.65 1.79 1.95 2.13 2.33 2.54 2.77 3.03 3.30 3.59 3.90 4.23 4.57 4.93 5.31 5.71 952 967 984 1002 1022 1044 1067 1092 1118 1146 1175 1206 1238 1271 1306 - 1.83 1.97 2.13 2.31 2.50 2.72 2.95 3.20 3.47 3.76 4.07 4.40 4.75 5.11 5.49 - Standard 3 HP & Drive 995 2.00 1037 2.17 1010 2.14 1053 2.31 1027 2.30 1069 2.47 1046 2.48 1088 2.65 1066 2.67 1108 2.84 1087 2.89 1129 3.06 1110 3.12 1152 3.29 1135 3.37 1177 3.54 1161 3.65 1203 3.82 1189 3.94 1231 4.11 1218 4.24 1260 4.42 1249 4.57 1291 4.74 1281 4.92 1323 5.09 1315 5.28 1357 5.45 1350 5.66 5 HP & Field Supplied Drive 1079 1094 1111 1129 1149 1171 1194 1219 1245 1273 1302 1333 1365 1398 - 2.34 2.48 2.64 2.82 3.02 3.23 3.46 3.72 3.99 4.28 4.59 4.91 5.26 5.62 - 1119 1135 1152 1170 1190 1211 1235 1259 1285 1313 1343 1373 1405 - 2.52 2.66 2.82 3.00 3.19 3.41 3.64 3.89 4.16 4.45 4.76 5.09 5.44 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 112 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ037-150 Bottom Duct Application ZJ037 (3.0 Ton) Bottom Duct Air Flow (CFM) 900 1000 1100 1200 1300 1400 1500 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 605 621 637 651 666 681 697 Standard 1.5 HP & Drive 0.23 671 0.33 738 0.25 688 0.34 754 0.27 703 0.36 769 0.30 717 0.39 784 0.33 732 0.43 799 0.37 747 0.47 814 0.42 763 0.51 830 0.42 0.44 0.46 0.49 0.52 0.56 0.61 804 820 835 850 865 880 896 0.52 0.53 0.56 0.58 0.62 0.66 0.71 869 885 900 915 930 945 961 Hi Static 1.5 HP & Drive 0.62 933 0.71 995 0.63 949 0.72 1011 0.65 964 0.74 1026 0.68 979 0.77 1041 0.71 994 0.81 1056 0.75 1009 0.85 1071 0.80 1025 0.90 1087 0.80 0.82 0.84 0.87 0.90 0.94 0.99 1054 0.89 1111 0.98 1071 0.91 1127 1.00 1086 0.93 1142 1.02 1100 0.96 1157 1.05 1115 0.99 1172 1.08 1130 1.03 1187 1.12 1146 1.08 1203 1.17 1.5 HP & Field Supplied Drive 1164 1180 1195 1210 1225 1240 1256 1.07 1.09 1.11 1.13 1.17 1.21 1.26 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZJ049 (4.0 Ton) Bottom Duct Air Flow (CFM) 1200 1300 1400 1500 1600 1700 1800 1900 2000 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 635 0.25 648 0.28 661 0.32 675 0.37 690 0.42 706 0.48 723 0.55 741 0.62 760 0.69 704 717 730 744 759 775 792 810 829 0.34 0.38 0.42 0.46 0.51 0.57 0.64 0.71 0.79 770 782 796 810 825 841 857 875 894 Standard 1.5 HP & Drive 0.44 832 0.54 893 0.47 845 0.58 906 0.51 858 0.62 919 0.56 872 0.66 933 0.61 887 0.72 948 0.67 903 0.77 964 0.74 920 0.84 981 0.81 938 0.91 999 0.88 957 0.99 1018 0.65 0.68 0.72 0.77 0.82 0.88 0.94 1.01 1.09 953 966 979 993 1008 1024 1041 1059 1078 0.75 0.78 0.82 0.87 0.92 0.98 1.04 1.11 1.19 1013 1025 1039 1053 1068 1084 1101 1118 1137 0.85 0.88 0.92 0.96 1.02 1.08 1.14 1.21 1.29 Hi Static 1.5 HP & Drive 1073 0.94 1134 1.02 1085 0.97 1147 1.05 1099 1.01 1160 1.09 1113 1.05 1174 1.14 1128 1.11 1189 1.19 1144 1.17 1205 1.25 1161 1.23 1222 1.31 1178 1.30 1240 1.38 1197 1.38 1258 1.46 1197 1210 1223 1237 1252 1268 1285 1303 1322 1.08 1.12 1.16 1.20 1.26 1.31 1.38 1.45 1.53 Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZJ061 (5.0 Ton) Bottom Duct Air Flow (CFM) 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive 673 0.47 736 0.54 797 693 0.49 756 0.57 817 713 0.53 777 0.60 837 734 0.57 797 0.65 858 755 0.62 819 0.70 879 776 0.69 840 0.76 900 798 0.76 861 0.84 921 819 0.84 882 0.92 943 840 0.93 903 1.01 964 861 1.03 925 1.11 985 882 1.14 946 1.22 1006 0.63 0.65 0.69 0.73 0.79 0.85 0.92 1.00 1.10 1.20 1.30 855 874 895 916 937 958 979 1001 1022 1043 1064 0.72 0.75 0.78 0.83 0.88 0.94 1.02 1.10 1.19 1.29 1.40 Standard 1.5 HP & Drive 910 0.82 964 0.92 930 0.85 984 0.95 951 0.88 1004 0.98 971 0.92 1025 1.03 992 0.98 1046 1.08 1014 1.04 1067 1.14 1035 1.11 1089 1.22 1056 1.20 1110 1.30 1077 1.29 1131 1.39 1099 1.39 1152 1.49 1120 1.50 1173 1.60 1016 1036 1057 1077 1098 1120 1141 1162 1183 1204 1226 1.03 1.06 1.09 1.14 1.19 1.25 1.32 1.41 1.50 1.60 1.71 1067 1087 1107 1128 1149 1171 1192 1213 1234 1255 1276 1.14 1.17 1.20 1.25 1.30 1.36 1.44 1.52 1.61 1.71 1.82 Hi Static 2 HP & Drive 1117 1.25 1166 1.36 1137 1.28 1186 1.39 1157 1.31 1207 1.42 1178 1.36 1228 1.47 1199 1.41 1249 1.52 1221 1.47 1270 1.59 1242 1.55 1291 1.66 1263 1.63 1312 1.74 1284 1.72 1334 1.83 1305 1.82 1355 1.93 1326 1.93 1376 2.04 2 HP & Field Supplied Drive 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 113 528150-YTG-T-0514 ZJ078 (6.5 Ton) Bottom Duct Air Flow (CFM) 1800 2000 2200 2400 2600 2800 3000 3200 3400 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 603 0.13 627 0.26 650 0.40 673 0.55 696 0.71 720 0.87 745 1.05 771 1.24 797 1.44 656 680 703 726 749 773 798 824 850 0.36 0.49 0.63 0.78 0.94 1.10 1.28 1.47 1.67 Standard 1.5 HP & Drive 718 0.58 784 0.79 742 0.71 808 0.92 765 0.85 831 1.06 788 1.00 854 1.21 811 1.16 878 1.37 835 1.32 902 1.53 860 1.50 926 1.71 886 1.69 952 1.90 912 1.89 979 2.10 851 875 898 921 944 968 993 1019 1045 0.98 1.12 1.25 1.40 1.56 1.73 1.91 2.09 2.29 914 937 961 984 1007 1031 1056 1081 1108 1.16 1.29 1.43 1.58 1.73 1.90 2.08 2.27 2.47 968 992 1015 1038 1061 1085 1110 1136 1162 Hi Static 2 HP & Drive 1.31 1010 1.43 1035 1.53 1.44 1034 1.57 1059 1.66 1.58 1057 1.71 1082 1.80 1.73 1080 1.85 1105 1.95 1.89 1103 2.01 1128 2.10 2.05 1127 2.18 1152 2.27 2.23 1152 2.36 1177 2.45 2.42 1178 2.54 1203 2.64 2.62 1204 2.74 1229 2.84 3 HP & Field Supplied Drive 1039 1063 1086 1109 1133 1157 1181 1207 1234 1.59 1.72 1.86 2.01 2.16 2.33 2.51 2.70 2.90 Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZJ090 (7.5 Ton) Bottom Duct Air Flow (CFM) 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 1. 2. 3. 4. Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 644 0.11 666 0.26 689 0.42 712 0.60 736 0.80 761 1.00 787 1.22 813 1.46 841 1.70 869 1.96 698 720 743 766 790 815 840 867 894 923 0.38 0.53 0.69 0.87 1.06 1.27 1.49 1.73 1.97 2.22 755 777 800 823 847 872 898 924 952 980 Standard 1.5 HP & Drive 0.62 814 0.85 874 0.77 836 1.00 896 0.93 859 1.16 919 1.11 882 1.34 942 1.31 906 1.53 967 1.52 931 1.74 991 1.74 957 1.96 1017 1.97 984 2.19 1044 2.21 1011 2.44 1071 2.47 1039 2.69 1099 1.06 1.21 1.37 1.55 1.74 1.95 2.17 2.40 2.65 2.90 933 956 978 1002 1026 1051 1076 1103 1130 1158 1.26 1.41 1.57 1.75 1.94 2.15 2.37 2.61 2.85 3.10 990 1012 1035 1058 1082 1107 1133 1160 1187 1215 1.46 1.61 1.77 1.95 2.14 2.35 2.57 2.80 3.05 3.30 Hi Static 3 HP & Drive 1043 1.66 1090 1.87 1131 1065 1.81 1113 2.02 1153 1088 1.97 1135 2.18 1176 1111 2.15 1159 2.36 1199 1135 2.34 1183 2.55 1223 1160 2.55 1208 2.76 1248 1186 2.77 1233 2.98 1274 1212 3.01 1260 3.21 3 HP & Field Supplied Drive 2.09 2.24 2.40 2.58 2.78 2.98 3.20 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZJ102 (8.5 Ton) Bottom Duct Air Flow (CFM) 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 1. 2. 3. 4. 114 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 685 0.59 702 0.70 722 0.83 744 0.97 769 1.13 797 1.32 828 1.52 861 1.75 897 2.00 935 2.27 976 2.57 739 756 776 798 823 851 882 915 951 989 1030 0.74 0.85 0.97 1.12 1.28 1.46 1.67 1.90 2.15 2.42 2.72 Standard 2 HP & Drive 791 0.88 841 1.01 808 0.99 858 1.12 828 1.11 878 1.25 850 1.26 900 1.39 875 1.42 925 1.55 903 1.60 953 1.74 934 1.81 983 1.94 967 2.04 1017 2.17 1002 2.29 1052 2.42 1041 2.56 1091 2.69 1082 2.86 1132 2.99 889 906 926 949 974 1001 1032 1065 1101 1139 1180 1.14 1.25 1.37 1.52 1.68 1.86 2.07 2.30 2.55 2.82 3.12 936 953 973 995 1020 1048 1078 1112 1147 1186 1227 Hi Static 3 HP & Drive 1.27 981 1.39 1025 1.51 1069 1.37 999 1.49 1043 1.62 1086 1.50 1018 1.62 1063 1.74 1106 1.64 1041 1.76 1085 1.88 1128 1.80 1066 1.92 1110 2.05 1153 1.99 1093 2.11 1138 2.23 1181 2.19 1124 2.32 1168 2.44 1212 2.42 1157 2.54 1201 2.67 1245 2.67 1193 2.80 1237 2.92 1280 2.95 1231 3.07 1275 3.19 1319 3.24 1272 3.36 3 HP & Field Supplied Drive 1.63 1.74 1.86 2.00 2.17 2.35 2.56 2.79 3.04 3.31 - 1111 1129 1149 1171 1196 1224 1254 1287 1323 1362 - 1.75 1.86 1.99 2.13 2.29 2.48 2.68 2.91 3.16 3.43 - Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ120 (10 Ton) Bottom Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 722 0.83 744 0.97 769 1.13 797 1.32 828 1.52 861 1.75 897 2.00 935 2.27 976 2.57 1019 2.88 1065 3.22 Standard 2 HP & Drive 776 798 823 851 882 915 951 989 1030 1073 1119 0.97 1.12 1.28 1.46 1.67 1.90 2.15 2.42 2.72 3.03 3.36 828 850 875 903 934 967 1002 1041 1082 1125 - 1.11 1.26 1.42 1.60 1.81 2.04 2.29 2.56 2.86 3.17 - 878 900 925 953 983 1017 1052 1091 1132 1175 - 1.25 1.39 1.55 1.74 1.94 2.17 2.42 2.69 2.99 3.30 - 926 949 974 1001 1032 1065 1101 1139 1180 1223 - Hi Static 3 HP & Drive 1.37 973 1.50 1018 1.52 995 1.64 1041 1.68 1020 1.80 1066 1.86 1048 1.99 1093 2.07 1078 2.19 1124 2.30 1112 2.42 1157 2.55 1147 2.67 1193 2.82 1186 2.95 1231 3.12 1227 3.24 1272 3.43 3 HP & Field Supplied Drive 1.62 1.76 1.92 2.11 2.32 2.54 2.80 3.07 3.36 - 1063 1085 1110 1138 1168 1201 1237 1275 - 1.74 1.88 2.05 2.23 2.44 2.67 2.92 3.19 - 1106 1128 1153 1181 1212 1245 1280 1319 - 1.86 2.00 2.17 2.35 2.56 2.79 3.04 3.31 - 1149 1171 1196 1224 1254 1287 1323 1362 - 1.99 2.13 2.29 2.48 2.68 2.91 3.16 3.43 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZJ150 (12.5 Ton) Bottom Duct Air Flow (CFM) 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Field Supplied Drive 797 1.32 851 1.46 828 1.52 882 1.67 861 1.75 915 1.90 897 2.00 951 2.15 935 2.27 989 2.42 976 2.57 1030 2.72 1019 2.88 1073 3.03 1065 3.22 1119 3.36 1113 3.57 1167 3.72 1163 3.94 1217 4.09 1216 4.34 1270 4.48 1270 4.75 1324 4.89 1327 5.17 1381 5.32 1385 5.62 - 903 934 967 1002 1041 1082 1125 1171 1219 1269 1321 1376 1433 - 1.60 1.81 2.04 2.29 2.56 2.86 3.17 3.50 3.86 4.23 4.62 5.03 5.46 - 953 983 1017 1052 1091 1132 1175 1221 1269 1319 1371 1426 1483 - Standard 3 HP & Drive 1.74 1001 1.86 1048 1.99 1.94 1032 2.07 1078 2.19 2.17 1065 2.30 1112 2.42 2.42 1101 2.55 1147 2.67 2.69 1139 2.82 1186 2.95 2.99 1180 3.12 1227 3.24 3.30 1223 3.43 1270 3.55 3.64 1269 3.76 1316 3.89 3.99 1317 4.12 1364 4.24 4.36 1367 4.49 1414 4.62 4.76 1420 4.88 1466 5.01 5.17 1474 5.29 1521 5.42 5.59 1531 5.72 5 HP & Field Supplied Drive 1093 1124 1157 1193 1231 1272 1315 1361 1409 1459 1512 1566 - 2.11 2.32 2.54 2.80 3.07 3.36 3.67 4.01 4.36 4.74 5.13 5.54 - 1138 1168 1201 1237 1275 1316 1360 1405 1453 1504 1556 1611 - Hi Static 5 HP & Drive 2.23 1181 2.35 1224 2.44 1212 2.56 1254 2.67 1245 2.79 1287 2.92 1280 3.04 1323 3.19 1319 3.31 1362 3.48 1360 3.60 1402 3.80 1403 3.92 1446 4.13 1449 4.25 1491 4.48 1497 4.61 1540 4.86 1547 4.98 1590 5.25 1600 5.37 1642 5.66 - 2.48 2.68 2.91 3.16 3.43 3.73 4.04 4.38 4.73 5.10 5.50 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 115 528150-YTG-T-0514 ZR037-150 Side Duct Application ZR037 (3.0 Ton) Side Duct 1 Available External Static Pressure - IWG Air Flow 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 Standard 1.5 HP & Drive Hi Static 1.5 HP & Drive 900 480 0.4 582 0.4 673 0.5 756 0.5 830 0.6 898 0.7 960 0.8 1018 0.9 1072 1.0 1124 1.1 1000 489 0.4 591 0.4 682 0.5 764 0.6 839 0.6 907 0.7 969 0.8 1026 0.9 1080 1.0 1132 1.1 1100 500 0.4 602 0.4 693 0.5 776 0.6 850 0.6 918 0.7 980 0.8 1038 0.9 1092 1.0 1144 1.1 1200 513 0.4 614 0.5 706 0.5 788 0.6 863 0.7 931 0.8 993 0.8 1050 0.9 1104 1.0 1156 1.1 1300 525 0.4 627 0.5 719 0.6 801 0.6 876 0.7 943 0.8 1005 0.9 1063 1.0 1117 1.1 1169 1.2 1400 537 0.5 639 0.5 731 0.6 813 0.7 888 0.7 955 0.8 1017 0.9 1075 1.0 1129 1.1 1181 1.2 1500 549 0.5 650 0.6 742 0.6 824 0.7 899 0.8 966 0.9 1028 0.9 1086 1.0 1140 1.1 1192 1.2 1. 2. 3. 4. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZR049 (4.0 Ton) Side Duct 1 Available External Static Pressure - IWG Air Flow 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive Standard 1.5 HP & Drive Hi Static 1.5 HP & Drive 1200 513 0.4 614 0.5 706 0.5 788 0.6 863 0.7 931 0.8 993 0.8 1050 0.9 1104 1.0 1156 1.1 1300 525 0.4 627 0.5 719 0.6 801 0.6 876 0.7 943 0.8 1005 0.9 1063 1.0 1117 1.1 1169 1.2 1400 537 0.5 639 0.5 731 0.6 813 0.7 888 0.7 955 0.8 1017 0.9 1075 1.0 1129 1.1 1181 1.2 1500 549 0.5 650 0.6 742 0.6 824 0.7 899 0.8 966 0.9 1028 0.9 1086 1.0 1140 1.1 1192 1.2 1600 558 0.6 660 0.6 752 0.7 834 0.8 909 0.8 976 0.9 1038 1.0 1096 1.1 1150 1.2 1202 1.3 1700 566 0.6 668 0.7 760 0.7 842 0.8 917 0.9 984 1.0 1046 1.1 1104 1.1 1158 1.2 1210 1.4 1800 573 0.7 675 0.7 766 0.8 849 0.9 923 1.0 991 1.0 1053 1.1 1110 1.2 1164 1.3 1216 1.4 1900 577 0.8 679 0.8 771 0.9 853 1.0 928 1.0 995 1.1 1057 1.2 1115 1.3 1169 1.4 1221 1.5 2000 580 0.8 682 0.9 773 1.0 856 1.0 930 1.1 998 1.2 1060 1.3 1117 1.4 1172 1.5 1224 1.6 FS4 1. 2. 3. 4. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZR061 (5.0 Ton) Side Duct Air Flow (CFM) Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard 1.5 HP & Drive Hi Static 2 HP & Drive 1500 616 0.5 685 0.6 766 0.7 833 0.8 905 0.9 975 1.0 1035 1.0 1101 1.1 1163 1.2 1229 1600 638 0.6 707 0.7 781 0.7 848 0.8 920 0.9 990 1.0 1050 1.1 1104 1.1 1166 1.2 1232 1.3 1.3 1700 655 0.6 724 0.7 796 0.8 863 0.9 935 1.0 1005 1.1 1064 1.1 1109 1.2 1172 1.3 1238 1.4 1800 670 0.7 739 0.8 810 0.8 877 0.9 949 1.0 1018 1.1 1078 1.2 1117 1.2 1179 1.3 1245 1.5 1900 686 0.7 755 0.8 823 0.9 890 1.0 962 1.1 1032 1.2 1091 1.2 1125 1.3 1187 1.4 1253 1.5 2000 702 0.8 772 0.9 836 1.0 903 1.1 975 1.2 1045 1.3 1078 1.3 1135 1.4 1197 1.5 1263 1.6 2100 722 0.9 791 1.0 849 1.0 916 1.1 988 1.2 1058 1.3 1089 1.4 1147 1.5 1209 1.6 1275 1.7 2200 745 0.9 814 1.0 861 1.1 928 1.2 1000 1.3 1050 1.4 1102 1.5 1159 1.6 1221 1.7 1287 1.8 2300 772 1.0 841 1.1 874 1.2 941 1.3 1013 1.4 1064 1.5 1115 1.6 1173 1.7 1235 1.8 - - 2400 804 1.1 832 1.2 886 1.3 953 1.4 1033 1.4 1078 1.6 1130 1.7 1188 1.8 - - - - 2500 841 1.2 844 1.3 898 1.4 965 1.5 1049 1.5 1094 1.7 - - - - 2 HP & Field Supplied Drive 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 116 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078-150 Side Duct Application ZR078 (6.5 Ton) Side Duct Air Flow (CFM) 1800 2000 2200 2400 2600 2800 3000 3200 3400 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 778 803 833 866 902 941 983 1028 1074 1.5 HP & Field Supplied Drive 0.37 838 0.56 895 0.50 864 0.69 921 0.64 893 0.83 951 0.80 926 0.99 984 0.97 962 1.16 1020 1.16 1002 1.35 1059 1.37 1043 1.56 1101 1.60 1088 1.79 1145 1.84 1134 2.03 1192 0.73 0.85 1.00 1.15 1.33 1.52 1.73 1.95 2.20 951 977 1006 1039 1076 1115 1157 1201 - 0.88 1.00 1.14 1.30 1.47 1.67 1.88 2.10 - Standard 1.5 HP & Drive 1005 1.01 1059 1.13 1031 1.14 1085 1.26 1061 1.28 1114 1.40 1094 1.43 1147 1.56 1130 1.61 1183 1.73 1169 1.80 1222 1.92 1211 2.01 1264 2.13 1255 2.24 - 1112 1138 1168 1201 1237 1276 1318 - Hi Static 2 HP & Drive 1.25 1166 1.36 1221 1.47 1278 1.37 1192 1.49 1247 1.60 1304 1.51 1221 1.63 1276 1.74 1333 1.67 1254 1.78 1309 1.90 1366 1.85 1291 1.96 1346 2.07 1402 2.04 1330 2.15 1385 2.26 2.25 2 HP & Field Supplied Drive 1.59 1.72 1.86 2.02 2.19 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZR090 (7.5 Ton) Side Duct Air Flow (CFM) 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive 803 0.50 864 0.69 833 0.64 893 0.83 866 0.80 926 0.99 902 0.97 962 1.16 941 1.16 1002 1.35 983 1.37 1043 1.56 1028 1.60 1088 1.79 1074 1.84 1134 2.03 1123 2.10 1183 2.29 1174 2.38 1234 2.57 921 951 984 1020 1059 1101 1145 1192 1241 1292 0.85 1.00 1.15 1.33 1.52 1.73 1.95 2.20 2.46 2.74 Standard 1.5 HP & Drive 977 1.00 1031 1.14 1006 1.14 1061 1.28 1039 1.30 1094 1.43 1076 1.47 1130 1.61 1115 1.67 1169 1.80 1157 1.88 1211 2.01 1201 2.10 1255 2.24 1248 2.35 1302 2.48 1297 2.61 1351 2.74 1348 2.88 1402 3.02 1085 1114 1147 1183 1222 1264 1309 1355 1404 1455 1.26 1.40 1.56 1.73 1.92 2.13 2.36 2.60 2.86 3.14 Hi Static 3 HP & Drive 1138 1.37 1192 1.49 1247 1.60 1168 1.51 1221 1.63 1276 1.74 1201 1.67 1254 1.78 1309 1.90 1237 1.85 1291 1.96 1346 2.07 1276 2.04 1330 2.15 1385 2.26 1318 2.25 1372 2.36 1427 2.47 1362 2.47 1416 2.59 1471 2.70 1409 2.72 1463 2.83 1518 2.94 1458 2.98 1512 3.09 1567 3.21 1509 3.26 1562 3.37 3 HP & Field Supplied Drive 1304 1333 1366 1402 1442 1483 1528 1574 1623 - 1.72 1.86 2.02 2.19 2.38 2.59 2.82 3.06 3.32 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZR102 (8.5 Ton) Side Duct Air Flow (CFM) 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2 HP & Field Supplied Drive 684 0.48 695 0.58 706 0.67 719 0.78 732 0.89 747 1.02 764 1.16 783 1.33 803 1.51 825 1.71 849 1.92 Standard 2 HP & Drive 735 745 756 769 782 797 814 833 853 875 899 0.67 0.76 0.86 0.96 1.08 1.21 1.35 1.51 1.69 1.89 2.11 783 793 805 817 831 846 862 881 901 923 947 0.84 0.94 1.04 1.14 1.25 1.38 1.53 1.69 1.87 2.07 2.29 829 840 851 863 877 892 909 927 948 970 993 1.01 1.11 1.20 1.31 1.42 1.55 1.69 1.86 2.04 2.23 2.45 874 885 896 908 922 937 954 972 992 1014 1038 Hi Static 3 HP & Drive 1.17 1.27 1.36 1.47 1.58 1.71 1.85 2.02 2.20 2.39 2.61 918 928 939 952 965 980 997 1016 1036 1058 1082 1.32 1.42 1.52 1.62 1.74 1.86 2.01 2.17 2.35 2.55 2.77 960 970 981 994 1007 1023 1039 1058 1078 1100 1124 1.48 1.57 1.67 1.78 1.89 2.02 2.16 2.32 2.50 2.70 2.92 1001 1.63 1041 1.78 1011 1.73 1052 1.88 1023 1.82 1063 1.98 1035 1.93 1075 2.08 1049 2.04 1089 2.19 1064 2.17 1104 2.32 1080 2.31 1121 2.47 1099 2.48 1139 2.63 1119 2.66 1159 2.81 1141 2.86 1181 3.01 1165 3.07 1205 3.23 3 HP & Field Supplied Drive 1081 1091 1103 1115 1128 1144 1160 1179 1199 1221 1245 1.94 2.04 2.13 2.24 2.35 2.48 2.62 2.79 2.97 3.16 3.38 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 117 528150-YTG-T-0514 ZR120 (10 Ton) Side Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2 HP & Field Supplied Drive 706 0.67 756 0.86 719 0.78 769 0.96 732 0.89 782 1.08 747 1.02 797 1.21 764 1.16 814 1.35 783 1.33 833 1.51 803 1.51 853 1.69 825 1.71 875 1.89 849 1.92 899 2.11 874 2.16 924 2.35 901 2.42 952 2.61 930 2.70 981 2.88 961 2.99 1011 3.18 805 817 831 846 862 881 901 923 947 972 1000 1029 1059 1.04 1.14 1.25 1.38 1.53 1.69 1.87 2.07 2.29 2.52 2.78 3.06 3.35 Standard 2 HP & Drive 851 1.20 896 1.36 863 1.31 908 1.47 877 1.42 922 1.58 892 1.55 937 1.71 909 1.69 954 1.85 927 1.86 972 2.02 948 2.04 992 2.20 970 2.23 1014 2.39 993 2.45 1038 2.61 1019 2.69 1064 2.85 1046 2.95 1091 3.11 1075 3.23 1120 3.39 - 939 952 965 980 997 1016 1036 1058 1082 1107 1134 - 1.52 1.62 1.74 1.86 2.01 2.17 2.35 2.55 2.77 3.01 3.26 - Hi Static 3 HP & Drive 981 1.67 1023 1.82 1063 1.98 994 1.78 1035 1.93 1075 2.08 1007 1.89 1049 2.04 1089 2.19 1023 2.02 1064 2.17 1104 2.32 1039 2.16 1080 2.31 1121 2.47 1058 2.32 1099 2.48 1139 2.63 1078 2.50 1119 2.66 1159 2.81 1100 2.70 1141 2.86 1181 3.01 1124 2.92 1165 3.07 1205 3.23 1149 3.16 1190 3.31 1177 3.42 3 HP & Field Supplied Drive 1103 1115 1128 1144 1160 1179 1199 1221 1245 - 2.13 2.24 2.35 2.48 2.62 2.79 2.97 3.16 3.38 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZR150 (12.5 Ton) Side Duct Air Flow (CFM) 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3 HP & Field Supplied Drive 747 1.02 797 1.21 846 764 1.16 814 1.35 862 783 1.33 833 1.51 881 803 1.51 853 1.69 901 825 1.71 875 1.89 923 849 1.92 899 2.11 947 874 2.16 924 2.35 972 901 2.42 952 2.61 1000 930 2.70 981 2.88 1029 961 2.99 1011 3.18 1059 993 3.31 1043 3.49 1092 1027 3.64 1077 3.83 1126 1063 3.99 1113 4.18 1161 1100 4.36 1150 4.55 1198 1138 4.75 1188 4.93 1237 1178 5.15 1228 5.34 1277 Hi Static 5 HP & Drive 1.38 1.53 1.69 1.87 2.07 2.29 2.52 2.78 3.06 3.35 3.67 4.00 4.35 4.72 5.11 5.51 892 909 927 948 970 993 1019 1046 1075 1106 1138 1172 1207 1244 1283 1323 1.55 1.69 1.86 2.04 2.23 2.45 2.69 2.95 3.23 3.52 3.84 4.17 4.52 4.89 5.28 5.68 937 954 972 992 1014 1038 1064 1091 1120 1151 1183 1217 1252 1289 1328 - 1.71 1.85 2.02 2.20 2.39 2.61 2.85 3.11 3.39 3.68 4.00 4.33 4.68 5.05 5.44 - Standard 3 HP & Drive 980 1.86 1023 2.02 997 2.01 1039 2.16 1016 2.17 1058 2.32 1036 2.35 1078 2.50 1058 2.55 1100 2.70 1082 2.77 1124 2.92 1107 3.01 1149 3.16 1134 3.26 1177 3.42 1163 3.54 1206 3.69 1194 3.84 1236 3.99 1226 4.15 1269 4.30 1260 4.48 1302 4.64 1296 4.84 1338 4.99 1333 5.20 1375 5.36 1371 5.59 1413 5.74 5 HP & Field Supplied Drive 1064 1080 1099 1119 1141 1165 1190 1218 1247 1277 1310 1344 1379 1416 - 2.17 2.31 2.48 2.66 2.86 3.07 3.31 3.57 3.85 4.14 4.46 4.79 5.14 5.51 - 1104 1121 1139 1159 1181 1205 1231 1258 1287 1318 1350 1384 1419 1456 - 2.32 2.47 2.63 2.81 3.01 3.23 3.47 3.72 4.00 4.29 4.61 4.94 5.29 5.66 - 1144 1160 1179 1199 1221 1245 1270 1298 1327 1357 1390 1424 1459 - 2.48 2.62 2.79 2.97 3.16 3.38 3.62 3.88 4.16 4.45 4.77 5.10 5.45 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 118 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037-150 Bottom Duct Application ZR037 (3.0 Ton) Bottom Duct 1 Available External Static Pressure - IWG Air Flow 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FS4 Standard 1.5 HP & Drive Hi Static 1.5 HP & Drive 900 544 0.4 632 0.5 708 0.5 774 0.6 834 0.7 889 0.8 941 0.9 993 1.0 1047 1.1 1104 1.2 1000 549 0.4 637 0.5 713 0.5 779 0.6 839 0.7 894 0.8 946 0.9 998 1.0 1052 1.1 1109 1.2 1100 562 0.4 649 0.5 725 0.6 792 0.6 852 0.7 906 0.8 959 0.9 1010 1.0 1064 1.1 1121 1.2 1200 579 0.5 666 0.5 742 0.6 809 0.6 868 0.7 923 0.8 975 0.9 1027 1.0 1081 1.1 1138 1.2 1300 598 0.5 685 0.5 761 0.6 828 0.7 887 0.8 942 0.8 994 0.9 1046 1.0 1100 1.2 1157 1.3 1400 617 0.5 705 0.6 781 0.6 847 0.7 907 0.8 962 0.9 1014 1.0 1066 1.1 1119 1.2 1177 1.3 1500 637 0.6 724 0.6 800 0.7 867 0.8 927 0.8 981 0.9 1034 1.0 1085 1.1 1139 1.2 1196 1.4 FS4 1. 2. 3. 4. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZR049 (4.0 Ton) Bottom Duct 1 Available External Static Pressure - IWG Air Flow 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard 1.5 HP & Drive Hi Static 1.5 HP & Drive 1200 579 0.5 666 0.5 742 0.6 809 0.6 868 0.7 923 0.8 975 0.9 1027 1.0 1081 1.1 1138 1300 598 0.5 685 0.5 761 0.6 828 0.7 887 0.8 942 0.8 994 0.9 1046 1.0 1100 1.2 1157 1.2 1.3 1400 617 0.5 705 0.6 781 0.6 847 0.7 907 0.8 962 0.9 1014 1.0 1066 1.1 1119 1.2 1177 1.3 1500 637 0.6 724 0.6 800 0.7 867 0.8 927 0.8 981 0.9 1034 1.0 1085 1.1 1139 1.2 1196 1.4 1600 655 0.6 743 0.7 819 0.7 885 0.8 945 0.9 1000 1.0 1052 1.1 1104 1.2 1158 1.3 1215 1.4 1700 672 0.7 760 0.7 836 0.8 902 0.9 962 1.0 1017 1.0 1069 1.1 1121 1.2 1175 1.3 1232 1.5 1800 687 0.7 775 0.8 851 0.9 918 0.9 977 1.0 1032 1.1 1084 1.2 1136 1.3 1190 1.4 1247 1.5 1900 700 0.8 788 0.9 864 0.9 930 1.0 990 1.1 1045 1.2 1097 1.3 1149 1.4 1202 1.5 1260 1.6 2000 711 0.9 798 0.9 874 1.0 941 1.1 1000 1.2 1055 1.2 1107 1.3 1159 1.4 1213 1.6 1270 1.7 FS4 1. 2. 3. 4. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = BHP x 0.932. Field Supplied Drive. ZR061 (5.0 Ton) Bottom Duct 1 Available External Static Pressure - IWG Air Flow 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Standard 1.5 HP & Drive Hi Static 2 HP & Drive 1500 613 0.5 684 0.6 759 0.7 831 0.7 928 0.8 984 0.9 1042 1.0 1093 1.1 1149 1.2 1201 1.3 1600 629 0.6 700 0.6 775 0.7 847 0.8 929 0.8 985 0.9 1043 1.0 1098 1.1 1154 1.2 1206 1.3 1700 646 0.6 717 0.7 793 0.8 864 0.8 934 0.9 990 1.0 1048 1.1 1106 1.2 1161 1.3 1214 1.4 1800 666 0.7 737 0.7 812 0.8 884 0.9 943 1.0 999 1.1 1057 1.2 1116 1.3 1172 1.4 1224 1.5 1900 687 0.7 758 0.8 833 0.9 905 0.9 954 1.0 1010 1.1 1068 1.2 1128 1.3 1184 1.4 1236 1.5 2000 710 0.8 781 0.9 856 0.9 927 1.0 968 1.1 1024 1.2 1082 1.3 1142 1.4 1198 1.5 1250 1.6 2100 733 0.8 804 0.9 879 1.0 951 1.1 983 1.2 1039 1.3 1097 1.4 1157 1.5 1213 1.6 1265 1.7 2200 758 0.9 828 1.0 904 1.1 947 1.2 1000 1.3 1056 1.4 1116 1.5 1174 1.6 1229 1.7 1281 1.8 2300 783 1.0 854 1.1 929 1.1 964 1.3 1018 1.4 1075 1.5 1133 1.6 1191 1.7 1246 1.8 - - 2400 809 1.1 879 1.2 932 1.3 983 1.4 1037 1.5 1094 1.6 1152 1.7 1209 1.8 - - - - 2500 835 1.1 906 1.2 951 1.4 1001 1.5 1055 1.6 1112 1.7 1170 1.8 2 HP & Field Supplied Drive 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 119 528150-YTG-T-0514 ZR078-150 Bottom Duct Application ZR078 (6.5 Ton) Bottom Duct Air Flow (CFM) 1800 2000 2200 2400 2600 2800 3000 3200 3400 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive 801 0.45 874 0.65 831 0.59 903 0.78 867 0.74 940 0.93 910 0.91 983 1.10 957 1.10 1030 1.30 1009 1.32 1082 1.51 1064 1.56 1137 1.75 1122 1.82 1194 2.02 1182 2.10 1254 2.30 946 975 1012 1055 1102 1154 1208 1266 - Standard 1.5 HP & Drive 0.82 1018 0.97 1090 0.95 1047 1.10 1119 1.10 1084 1.25 1156 1.27 1126 1.43 1199 1.47 1174 1.62 1246 1.69 1225 1.84 1298 1.92 1280 2.08 1353 2.19 - 1.11 1.24 1.39 1.57 1.76 1.98 2.22 - Hi Static 2 HP & Drive 1163 1.25 1238 1.38 1193 1.38 1267 1.51 1229 1.53 1304 1.66 1272 1.70 1347 1.84 1320 1.89 1394 2.03 1371 2.11 1446 2.25 2 HP & Field Supplied Drive 1315 1344 1381 1424 1471 - 1.52 1.66 1.81 1.98 2.17 - 1395 1424 1461 1503 - 1.68 1.81 1.96 2.14 - 1477 1507 1543 - 1.86 1.99 2.14 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZR090 (7.5 Ton) Bottom Duct Air Flow (CFM) 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.5 HP & Field Supplied Drive 831 0.59 867 0.74 910 0.91 957 1.10 1009 1.32 1064 1.56 1122 1.82 1182 2.10 1244 2.41 1308 2.73 Standard 1.5 HP & Drive 903 940 983 1030 1082 1137 1194 1254 1317 1381 0.78 0.93 1.10 1.30 1.51 1.75 2.02 2.30 2.60 2.93 975 1012 1055 1102 1154 1208 1266 1326 1389 1453 0.95 1.10 1.27 1.47 1.69 1.92 2.19 2.47 2.77 3.10 1047 1084 1126 1174 1225 1280 1338 1398 1461 1525 1.10 1.25 1.43 1.62 1.84 2.08 2.34 2.62 2.93 3.25 Hi Static 3 HP & Drive 1119 1156 1199 1246 1298 1353 1410 1471 1533 1597 1.24 1193 1.38 1267 1.39 1229 1.53 1304 1.57 1272 1.70 1347 1.76 1320 1.89 1394 1.98 1371 2.11 1446 2.22 1426 2.35 1501 2.48 1484 2.61 1559 2.76 1544 2.90 1619 3.07 1606 3.20 1681 3.39 3 HP & Field Supplied Drive 1.51 1.66 1.84 2.03 2.25 2.49 2.75 3.03 3.33 - 1344 1381 1424 1471 1523 1578 1636 1696 - 1.66 1.81 1.98 2.17 2.39 2.63 2.89 3.17 - 1424 1461 1503 1551 1602 1657 1715 1775 - 1.81 1.96 2.14 2.33 2.55 2.79 3.05 3.33 - 1507 1543 1586 1634 1685 1740 1798 - 1.99 2.14 2.31 2.51 2.73 2.96 3.23 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZR102 (8.5 Ton) Bottom Duct Air Flow (CFM) 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2 HP & Field Supplied Drive 715 0.72 768 734 0.83 786 755 0.95 808 779 1.09 832 806 1.25 859 837 1.44 889 870 1.65 922 906 1.88 959 945 2.13 998 987 2.40 1040 1032 2.70 1084 Standard 2 HP & Drive 0.85 0.96 1.08 1.22 1.38 1.57 1.78 2.01 2.26 2.53 2.83 818 837 858 882 910 940 973 1009 1048 1090 1135 0.98 1.08 1.20 1.35 1.51 1.69 1.90 2.13 2.38 2.66 2.95 867 886 907 931 958 989 1022 1058 1097 1139 1184 1.09 1.20 1.32 1.46 1.63 1.81 2.02 2.25 2.50 2.78 3.07 Hi Static 3 HP & Drive 914 933 954 978 1005 1036 1069 1105 1144 1186 1231 1.21 1.31 1.44 1.58 1.74 1.93 2.13 2.36 2.61 2.89 3.18 960 1.32 1004 1.43 978 1.42 1022 1.53 1000 1.55 1044 1.65 1024 1.69 1068 1.80 1051 1.85 1095 1.96 1081 2.04 1125 2.14 1114 2.24 1158 2.35 1150 2.47 1195 2.58 1190 2.72 1234 2.83 1231 3.00 1276 3.11 1276 3.29 1320 3.40 3 HP & Field Supplied Drive 1047 1066 1087 1111 1138 1168 1202 1238 1277 1319 - 1.53 1.64 1.76 1.90 2.07 2.25 2.46 2.69 2.94 3.21 - 1089 1108 1129 1153 1181 1211 1244 1280 1319 1361 - 1.64 1.75 1.87 2.01 2.17 2.36 2.57 2.80 3.05 3.32 - 1131 1150 1171 1195 1222 1252 1286 1322 1361 1403 - 1.75 1.86 1.98 2.12 2.28 2.47 2.68 2.91 3.16 3.43 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. 120 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR120 (10 Ton) Bottom Duct Air Flow (CFM) 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2 HP & Field Supplied Drive 755 0.95 808 779 1.09 832 806 1.25 859 837 1.44 889 870 1.65 922 906 1.88 959 945 2.13 998 987 2.40 1040 1032 2.70 1084 1079 3.01 1132 1129 3.35 - Standard 2 HP & Drive 1.08 1.22 1.38 1.57 1.78 2.01 2.26 2.53 2.83 3.15 - 858 882 910 940 973 1009 1048 1090 1135 1182 - 1.20 1.35 1.51 1.69 1.90 2.13 2.38 2.66 2.95 3.27 - 907 931 958 989 1022 1058 1097 1139 1184 1231 - 1.32 1.46 1.63 1.81 2.02 2.25 2.50 2.78 3.07 3.39 - Hi Static 3 HP & Drive 954 1.44 1000 1.55 978 1.58 1024 1.69 1005 1.74 1051 1.85 1036 1.93 1081 2.04 1069 2.13 1114 2.24 1105 2.36 1150 2.47 1144 2.61 1190 2.72 1186 2.89 1231 3.00 1231 3.18 1276 3.29 3 HP & Field Supplied Drive 1044 1068 1095 1125 1158 1195 1234 1276 1320 - 1.65 1.80 1.96 2.14 2.35 2.58 2.83 3.11 3.40 - 1087 1111 1138 1168 1202 1238 1277 1319 - 1.76 1.90 2.07 2.25 2.46 2.69 2.94 3.21 - 1129 1153 1181 1211 1244 1280 1319 1361 - 1.87 2.01 2.17 2.36 2.57 2.80 3.05 3.32 - 1171 1195 1222 1252 1286 1322 1361 1403 - 1.98 2.12 2.28 2.47 2.68 2.91 3.16 3.43 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. ZR150 (12.5 Ton) Bottom Duct Air Flow (CFM) 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 Available External Static Pressure - IWG1 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3 HP & Field Supplied Drive 837 1.44 870 1.65 906 1.88 945 2.13 987 2.40 1032 2.70 1079 3.01 1129 3.35 1182 3.71 1237 4.08 1294 4.48 1354 4.89 1416 5.33 - Standard 3 HP & Drive 889 922 959 998 1040 1084 1132 1182 1235 1290 1347 1407 1469 - 1.57 1.78 2.01 2.26 2.53 2.83 3.15 3.48 3.84 4.22 4.61 5.03 5.46 - 940 973 1009 1048 1090 1135 1182 1232 1285 1340 1398 1457 1519 - 1.69 1.90 2.13 2.38 2.66 2.95 3.27 3.61 3.96 4.34 4.74 5.15 5.58 - 989 1022 1058 1097 1139 1184 1231 1281 1334 1389 1446 1506 1568 - 1.81 2.02 2.25 2.50 2.78 3.07 3.39 3.72 4.08 4.46 4.85 5.27 5.70 - 1036 1.93 1081 2.04 1069 2.13 1114 2.24 1105 2.36 1150 2.47 1144 2.61 1190 2.72 1186 2.89 1231 3.00 1231 3.18 1276 3.29 1278 3.50 1324 3.61 1328 3.84 1374 3.95 1381 4.20 1426 4.31 1436 4.57 1481 4.68 1493 4.97 1539 5.08 1553 5.38 1599 5.49 5 HP & Field Supplied Drive Hi Static 5 HP & Drive 1125 1158 1195 1234 1276 1320 1368 1418 1471 1526 1583 1643 - 2.14 2.35 2.58 2.83 3.11 3.40 3.72 4.06 4.41 4.79 5.19 5.60 - 1168 1202 1238 1277 1319 1364 1411 1461 1514 1569 1626 1686 - 2.25 2.46 2.69 2.94 3.21 3.51 3.83 4.16 4.52 4.90 5.29 5.71 - 1211 1244 1280 1319 1361 1406 1453 1503 1556 1611 1669 - 2.36 2.57 2.80 3.05 3.32 3.62 3.93 4.27 4.63 5.01 5.40 - 1252 1286 1322 1361 1403 1447 1495 1545 1598 1653 1710 - 2.47 2.68 2.91 3.16 3.43 3.73 4.05 4.38 4.74 5.12 5.51 - 1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. 3. kW = BHP x 0.932. Johnson Controls Unitary Products 121 528150-YTG-T-0514 Sound Performance Indoor Sound Power Levels (3 thru 5 Ton) Indoor Sound Power Levels (Horizontal Ducted Inlet, Standard Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Return) Ducted Inlet 612 - 3 Turns Open Equivalent 709 - 1 Turn Open Equivalent 0.5 0.4 Airflow (CFM) 850 1300 Blower Motor BHP 0.37 External Static Pressure (IWG) 0.40 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 73 77 73 77 125 61 70 66 71 250 56 63 60 64 500 51 56 55 57 1000 44 48 51 52 2000 41 44 48 49 4000 44 47 47 48 8000 42 44 43 44 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Return) Ducted Inlet 612 - 3 Turns Open Equivalent 709 - 1 Turn Open Equivalent External Static Pressure (IWG) 0.5 0.4 Airflow (CFM) 850 1300 Blower Motor BHP 0.37 Octave Center Freq. Hz ID Blower Only (dB) 0.40 Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 73 77 73 77 125 61 70 66 71 250 56 63 60 64 500 51 56 55 57 1000 44 48 51 52 2000 41 44 48 49 4000 44 47 47 48 8000 42 44 43 44 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. 122 Johnson Controls Unitary Products 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive TEST CONFIGURATION Horizontal (Side Return) Ducted Inlet Indoor Blower Speed (RPM) 814 - 3 Turns Open Equivalent 918 - 1 Turn Open Equivalent 0.6 0.8 Airflow (CFM) 1700 1950 Blower Motor BHP 0.42 External Static Pressure (IWG) 0.88 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 77 81 85 82 125 71 80 68 81 250 63 67 64 68 500 58 60 60 61 1000 56 57 58 59 2000 52 53 55 55 4000 51 51 54 54 8000 47 47 48 48 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Indoor Sound Power Levels (Horizontal Ducted Discharge, Standard Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive TEST CONFIGURATION Horizontal (Side Supply) Ducted Discharge Indoor Blower Speed (RPM) 610 - 3 Turns Open Equivalent 710 - 1 Turn Open Equivalent External Static Pressure (IWG) 0.5 0.6 Airflow (CFM) 850 950 Blower Motor BHP 0.37 Octave Center Freq. Hz ID Blower Only (dB) 0.42 Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 77 78 79 79 125 74 75 75 76 250 66 68 70 70 500 61 61 65 64 1000 60 62 65 66 2000 52 52 58 58 4000 52 52 59 60 8000 44 44 50 50 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Johnson Controls Unitary Products 123 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Supply) Ducted Discharge 610 - 3 Turns Open Equivalent 710 - 1 Turn Open Equivalent 0.5 0.6 External Static Pressure (IWG) Airflow (CFM) 850 950 Blower Motor BHP 0.37 0.42 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 77 78 79 79 125 74 75 75 76 250 66 68 70 70 500 61 61 65 64 1000 60 62 65 66 2000 52 52 58 58 4000 52 52 59 60 8000 44 44 50 50 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Supply) Ducted Discharge 810 - 3 Turns Open Equivalent External Static Pressure (IWG) 918 - 1 Turn Open Equivalent 0.4 0.8 Airflow (CFM) 2050 1950 Blower Motor BHP 0.73 0.88 1 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 85 83 83 83 125 78 79 76 79 250 69 70 69 70 500 68 68 68 68 1000 64 64 65 65 2000 63 63 64 64 4000 64 64 64 64 8000 59 59 59 60 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. 124 Johnson Controls Unitary Products 528150-YTG-T-0514 Indoor Sound Power Levels (Vertical Ducted Inlet, Standard Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive TEST CONFIGURATION Vertical (Bottom Return) Ducted Inlet Indoor Blower Speed (RPM) 609 - 3 Turns Open Equivalent 708 - 1 Turn Open Equivalent 0.4 0.4 Airflow (CFM) 850 1150 Blower Motor BHP 0.32 External Static Pressure (IWG) 0.38 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 76 76 74 76 125 63 70 66 70 250 55 62 59 62 500 54 55 58 59 1000 48 48 53 53 2000 44 44 48 48 4000 41 44 45 46 8000 42 43 43 44 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive TEST CONFIGURATION Vertical (Bottom Return) Ducted Inlet 609 - 3 Turns Open Equivalent Indoor Blower Speed (RPM) 708 - 1 Turn Open Equivalent External Static Pressure (IWG) 0.4 0.4 Airflow (CFM) 850 1150 Blower Motor BHP 0.32 Octave Center Freq. Hz ID Blower Only (dB) 0.38 Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 76 76 74 76 125 63 70 66 70 250 55 62 59 62 500 54 55 58 59 1000 48 48 53 53 2000 44 44 48 48 4000 41 44 45 46 8000 42 43 43 44 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Johnson Controls Unitary Products 125 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Vertical (Bottom Return) Ducted Inlet 812 - 3 Turns Open Equivalent 915- 1 Turn Open Equivalent 0.6 0.8 Airflow (CFM) 1575 1800 Blower Motor BHP 0.64 External Static Pressure (IWG) Octave Center Freq. Hz ID Blower Only (dB) 0.83 Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 75 78 80 80 125 66 80 69 81 250 59 66 62 65 500 60 60 63 63 1000 57 57 60 60 2000 52 53 55 55 4000 49 50 53 53 8000 44 45 47 47 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Indoor Sound Power Levels (Vertical Ducted Discharge, Standard Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Vertical (Bottom Supply) Ducted Discharge 609 - 3 Turns Open Equivalent 712 - 1 Turn Open Equivalent External Static Pressure (IWG) 0.4 0.6 Airflow (CFM) 850 950 Blower Motor BHP 0.32 0.42 1 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 76 77 81 81 125 68 68 72 72 250 55 65 57 57 500 56 57 57 57 1000 51 57 52 56 2000 49 49 50 50 4000 48 48 49 51 8000 46 46 47 48 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. 126 Johnson Controls Unitary Products 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive TEST CONFIGURATION Vertical (Bottom Supply) Ducted Discharge Indoor Blower Speed (RPM) 609 - 3 Turns Open Equivalent 712 - 1 Turn Open Equivalent 0.4 0.6 External Static Pressure (IWG) Airflow (CFM) 850 950 Blower Motor BHP 0.32 0.42 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 76 77 81 81 125 68 68 72 72 250 55 65 57 57 500 56 57 57 57 1000 51 57 52 56 2000 49 49 50 50 4000 48 48 49 51 8000 46 46 47 48 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive TEST CONFIGURATION Vertical (Bottom Supply) Ducted Discharge Indoor Blower Speed (RPM) 809 - 3 Turns Open Equivalent External Static Pressure (IWG) 914 - 1 Turn Open Equivalent 0.5 0.8 Airflow (CFM) 1700 1800 Blower Motor BHP 0.64 0.83 1 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 81 81 79 79 125 75 75 75 76 250 65 65 63 63 500 67 67 67 67 1000 63 63 63 63 2000 61 62 61 61 4000 62 62 61 61 8000 57 57 56 56 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Johnson Controls Unitary Products 127 528150-YTG-T-0514 Indoor Sound Power Levels (Horizontal Ducted Inlet, High Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive TEST CONFIGURATION Horizontal (Side Return) Ducted Inlet 876 - 4 Turns Open Equivalent 1,064 - 1/2 Turn Open Equivalent 1,190 - 2.5 Turns Open Equivalent1 1.0 1.6 2.0 1 Nominal Airflow (CFM) 1,200 1,100 1,000 Blower Motor BHP 0.64 0.93 Indoor Blower Speed (RPM) External Static Pressure (IWG) 1.08 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) 63 75 80 81 81 81 83 125 69 71 71 73 73 75 250 62 68 66 71 68 70 500 54 56 57 59 59 60 1000 52 56 56 58 58 60 2000 47 49 52 52 54 56 4000 43 45 48 49 51 53 8000 43 45 45 46 47 48 1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69. 2. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Return) Ducted Inlet 965 - 5.5 Turns Open Equivalent 1,088 - 4 Turns Open Equivalent 1.0 1.6 2.0 Nominal Airflow (CFM) 1,600 1,400 1,200 Blower Motor BHP 0.86 1.03 1.13 External Static Pressure (IWG) 1,186 - 2.5 Turns Open Equivalent Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 74 80 77 80 81 81 125 69 74 72 75 75 76 250 68 68 68 69 70 71 500 62 62 60 61 61 63 1000 60 61 58 58 59 60 2000 57 57 53 54 55 56 4000 56 56 49 50 51 52 8000 54 54 45 47 47 48 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. 128 Johnson Controls Unitary Products 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Return) Ducted Inlet 1,012- 5.5 Turns Open Equivalent 1,134 - 3 Turns Open Equivalent 1,174 - 2 Turns Open Equivalent 1.0 1.6 2.0 Nominal Airflow (CFM) 2,000 1,800 1,600 Blower Motor BHP 1.04 1.25 External Static Pressure (IWG) 1.39 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 76 78 78 79 79 81 125 70 73 73 76 74 77 250 68 70 68 69 69 70 500 61 62 61 62 60 62 1000 61 62 61 62 58 60 2000 57 58 57 58 54 56 4000 56 56 55 56 52 53 8000 50 50 50 50 47 48 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Indoor Sound Power Levels (Horizontal Ducted Discharge, High Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive Horizontal (Side Supply) Ducted Discharge TEST CONFIGURATION 896 - 3.5 Turns Open Equivalent 1,072 - Fully Closed Equivalent 1,170 - 2.5 Turns Open Equivalent1 1.0 1.6 2.0 1 Nominal Airflow (CFM) 1,200 1,100 1,000 Blower Motor BHP 0.64 0.93 1.08 Indoor Blower Speed (RPM) External Static Pressure (IWG) Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) 63 77 81 83 84 83 84 125 74 76 76 77 80 80 250 67 68 70 70 72 73 500 65 66 67 67 67 68 1000 61 62 67 67 66 69 2000 58 60 63 63 63 64 4000 57 59 62 62 62 63 8000 51 53 56 57 56 58 1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69. 2. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Johnson Controls Unitary Products 129 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Horizontal (Side Supply) Ducted Discharge 922 - 6 Turns Open Equivalent 1,069 - 4 Turns Open Equivalent 1,165 - 2.5 Turns Open Equivalent 1.0 1.6 2.0 Nominal Airflow (CFM) 1,600 1,400 1,200 Blower Motor BHP 0.86 1.03 External Static Pressure (IWG) 1.13 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 80 82 82 83 84 84 125 76 77 76 77 78 79 250 71 72 72 72 74 74 500 69 69 69 69 70 70 1000 65 65 69 69 70 70 2000 64 64 64 64 65 65 4000 63 63 63 63 64 64 8000 58 58 58 58 59 59 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive Horizontal (Side Supply) Ducted Discharge TEST CONFIGURATION Indoor Blower Speed (RPM) 1,009- 5.5 Turns Open Equivalent 1,131 - 3 Turns Open Equivalent 1.0 1.6 2.0 2,000 1,800 1,600 External Static Pressure (IWG) Nominal Airflow (CFM) Blower Motor BHP Octave Center Freq. Hz 1.04 ID Blower Only (dB) 1,184 - 2 Turns Open Equivalent 1.25 Cooling Operation1 (dB) ID Blower Only (dB) 1.39 Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 84 85 82 83 82 83 125 78 79 79 79 78 79 250 75 75 74 75 73 73 500 71 71 70 71 69 69 1000 69 69 71 71 71 72 2000 66 67 67 67 66 66 4000 66 66 66 67 66 66 8000 61 62 61 62 60 60 1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. 130 Johnson Controls Unitary Products 528150-YTG-T-0514 Indoor Sound Power Levels (Vertical Ducted Inlet, High Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive TEST CONFIGURATION Vertical (Bottom Return) Ducted Inlet 927 - 3 Turns Open Equivalent 1,085 - 1/2 Turn Open Equivalent 1,190 - 2.5 Turns Open Equivalent1 1.0 1.6 2.01 Nominal Airflow (CFM) 1,200 1,100 1,000 Blower Motor BHP 0.68 0.93 1.09 Indoor Blower Speed (RPM) External Static Pressure (IWG) Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) 63 77 79 82 83 79 81 125 68 69 70 71 72 73 250 60 67 62 69 64 67 500 58 58 63 63 62 63 1000 54 55 60 60 60 60 2000 48 49 56 56 55 55 4000 43 44 48 49 51 51 8000 44 44 45 46 47 47 1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69. 2. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Vertical (Bottom Return) Ducted Inlet 968 - 5.5 Turns Open Equivalent 1,120 - 3.5 Turns Open Equivalent 1,218 - 2.0 Turns Open Equivalent 1.0 1.6 2.0 Nominal Airflow (CFM) 1,600 1,400 1,200 Blower Motor BHP 0.86 1.03 1.13 External Static Pressure (IWG) Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 77 79 78 78 81 81 125 69 73 71 73 73 74 250 63 63 63 64 66 66 500 63 64 62 63 64 64 1000 59 59 59 59 61 61 2000 54 54 53 54 56 56 4000 49 49 48 48 50 51 8000 45 46 45 46 47 47 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Johnson Controls Unitary Products 131 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Vertical (Bottom Return) Ducted Inlet 1,039 - 5 Turns Open Equivalent 1,143 - 3 Turns Open Equivalent 1,201 - 2 Turns Open Equivalent 1.0 1.6 2.0 Nominal Airflow (CFM) 2,000 1,800 1,600 Blower Motor BHP 1.11 1.25 External Static Pressure (IWG) 1.39 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 79 80 77 77 81 81 125 74 75 71 73 73 74 250 63 65 63 64 63 65 500 62 63 64 64 62 62 1000 61 61 61 61 59 59 2000 55 56 55 56 54 55 4000 52 52 50 51 50 50 8000 47 47 46 46 46 46 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Indoor Sound Power Levels (Vertical Ducted Discharge, High Static Belt Drive) UNIT DESCRIPTION / MODEL ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive TEST CONFIGURATION Vertical (Bottom Supply) Ducted Discharge 920 - 3.0 Turns Open Equivalent 1,074 - Fully Closed Equivalent 1,189 - 2.0 Turns Open Equivalent1 1.0 1.6 2.01 Nominal Airflow (CFM) 1,200 1,100 1,000 Blower Motor BHP 0.68 0.93 1.09 Indoor Blower Speed (RPM) External Static Pressure (IWG) Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) ID Blower Only (dB) Cooling Operation2 (dB) 63 81 82 81 81 82 82 125 78 78 78 78 81 81 250 69 70 70 71 74 74 500 67 68 68 69 71 71 1000 62 63 67 68 70 71 2000 60 61 62 63 65 66 4000 61 61 63 63 66 66 8000 54 55 57 57 60 61 1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69. 2. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. 132 Johnson Controls Unitary Products 528150-YTG-T-0514 UNIT DESCRIPTION / MODEL ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Vertical (Bottom Supply) Ducted Discharge 962 - 5.5 Turns Open Equivalent 1,092 - 3.5 Turns Open Equivalent 1,190 - 2.0 Turns Open Equivalent 1.0 1.6 2.0 Nominal Airflow (CFM) 1,600 1,400 1,200 Blower Motor BHP 0.86 1.03 External Static Pressure (IWG) 1.13 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 83 84 82 82 83 83 125 80 81 79 80 80 81 250 75 75 74 75 75 75 500 71 72 70 71 71 72 1000 66 67 70 71 72 72 2000 63 64 64 64 65 65 4000 64 64 64 64 65 66 8000 58 59 59 59 60 60 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. UNIT DESCRIPTION / MODEL ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive TEST CONFIGURATION Indoor Blower Speed (RPM) Vertical (Bottom Supply) Ducted Discharge 1,033 - 5.5 Turns Open Equivalent 1,135 - 3 turns Open Equivalent 1.0 1.6 2.0 2,000 1,135 1,175 External Static Pressure (IWG) Nominal Airflow (CFM) Blower Motor BHP 1.11 1,175 - 2.5 Turns Open Equivalent 1.25 1.39 Octave Center Freq. Hz ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) ID Blower Only (dB) Cooling Operation1 (dB) 63 83 83 83 83 85 86 125 84 84 82 82 79 81 250 79 80 77 78 66 66 500 73 73 70 71 65 66 1000 69 70 69 70 61 65 2000 67 67 65 66 60 61 4000 67 68 66 67 61 62 8000 62 63 60 61 54 54 1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test. • Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment. • Testing datum includes effect of standard inlet air filters. • Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows. • Test duct termination is flush with reverberant room wall. • Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively. Johnson Controls Unitary Products 133 528150-YTG-T-0514 Indoor Sound Power Levels (6.5 thru 12.5 Ton) Size (Tons) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) Model CFM ESP (IWG) Blower RPM BHP Sound Rating1 dB (A) 63 Sound Power, dB (10-12) Watts Octave Band Centerline Frequency (Hz) 125 250 500 1000 2000 4000 8000 ZH/ZJ/ZR 2600 0.6 812 1.14 74 71 73 73 71 69 65 65 60 ZH/ZJ/ZR 3000 0.6 854 1.47 77 74 76 76 74 72 68 68 63 ZH/ZJ/ZR 3400 0.6 872 1.65 80 77 79 79 77 75 71 71 66 ZH/ZJ/ZR 4000 0.6 959 2.29 83 80 82 82 80 78 74 74 69 ZH/ZJ/ZR 5000 0.6 1132 3.74 87 84 86 86 84 82 78 78 73 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data in any other form than sound power level ratings. 134 Johnson Controls Unitary Products 528150-YTG-T-0514 Outdoor Sound Power Levels ZH/ZJ/ZR037-150 Size (Tons) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 037 (3) 049 (4) 61 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) Model Sound Rating1 dB (A) 63 125 ZH 81 82.5 86.5 78.0 75.5 76.5 ZH 78 82.0 86.0 78.5 75.5 ZH 84 81.0 91.0 82.5 ZH 87 89.0 88.5 ZH 92 93.0 ZH 92 ZH Octave Band Centerline Frequency (Hz) 250 500 1000 2000 4000 8000 68.5 63.0 56.5 73.0 68.0 63.0 56.0 80.5 79.0 73.5 69.5 64.5 84.5 84.5 82.0 76.5 72.0 66.5 92.0 90.5 88.0 86.5 83.0 77.5 73.5 97.0 94.0 93.5 90.5 87.0 81.5 76.0 69.0 91 99.5 91.5 91.5 89.0 86.0 80.5 76.5 71.0 ZH 86 89.5 91.0 85.5 84.0 81.0 76.5 71.0 62.5 ZJ 77 82.0 83.5 80.0 73.0 70.0 65.5 60.5 55.5 ZJ 80 80.0 87.0 77.0 75.5 75.0 70.5 65.5 62.0 ZJ 84 86.5 87.0 86.0 79.0 76.5 71.5 68.0 64.0 ZJ 85 87.5 85.0 84.0 82.0 80.0 75.5 71.5 67.0 ZJ 90 90.0 93.0 90.5 86.0 83.5 81.5 78.0 75.0 ZJ 92 97.0 94.0 93.5 90.5 87.0 81.5 76.0 69.0 ZJ 91 99.5 91.5 91.5 89.0 86.0 80.5 76.5 71.0 ZJ 85 89.0 88.0 83.5 83.5 78.5 74.0 69.5 64.5 ZR 77 82.0 83.5 80.0 73.0 70.0 65.5 60.5 55.5 ZR 81 87.5 88.5 83.0 77.5 73.5 70.5 67.0 62.0 ZR 84 86.5 87.0 86.0 79.0 76.5 71.5 68.0 64.0 ZR 83 ~ 88.0 82.5 81.5 78.0 73.0 69.0 62.0 ZR 83 ~ 89.5 83.5 82.0 78.0 72.5 68.0 60.5 ZR 83 ~ 89.0 84.5 81.5 78.0 72.5 68.5 70.5 ZR 83 ~ 89.5 83.5 81.0 78.0 72.0 68.5 70.5 ZR 84 ~ 90.0 84.5 81.5 77.5 72.0 68.5 61.5 1. Rated in accordance with AHRI 270 standard. Johnson Controls Unitary Products 135 528150-YTG-T-0514 Electrical Data ZH037-061 Standard Indoor Blower - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.1 68 14.2 1.5 6.0 5.5 0.0 230 9.1 68 14.2 1.5 6.0 5.5 0.0 460 4.5 34 7 0.8 3.0 2.2 0.0 575 3.8 28 6 0.6 2.4 1.8 0.0 208 11.2 88 17.5 1.5 6.0 5.5 0.0 230 11.2 88 17.5 1.5 6.0 5.5 0.0 460 5.6 44 8.0 0.8 3.0 2.2 0.0 575 4.5 36 7.0 0.6 2.4 1.8 0.0 208 14.1 88 22 1.5 6.0 5.5 0.0 230 14.1 88 22 1.5 6.0 5.5 0.0 460 7.7 55 12 0.8 3.0 2.2 0.0 575 5.1 36 7.5 0.6 2.4 1.8 0.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA1 (Amps) Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 18.9 18.9 23.1 31.1 46.7 18.9 18.9 25.5 34.6 52.6 9.4 9.4 12.8 17.3 26.3 7.8 13.8 21 21.5 23.1 31.1 46.7 59.5 21.7 25.5 34.6 52.6 67.6 10.8 12.8 17.3 26.3 33.8 8.6 13.8 21 27.1 26.6 26.6 31.1 46.7 59.5 70 26.6 26.6 34.6 52.6 67.6 79.7 14.2 14.2 17.3 26.3 33.8 39.8 10 13.8 21 27.1 31.9 MCA1 w/Pwr Exh (Amps) 24.4 24.4 30 38 53.6 24.4 24.4 32.4 41.4 59.5 11.6 11.6 15.5 20 29.1 9.6 16.1 23.3 27 30 38 53.6 66.4 27 32.4 41.4 59.5 74.5 13 15.5 20 29.1 36.6 10.4 16.1 23.3 29.3 32.1 32.1 38 53.6 66.4 76.8 32.1 32.4 41.4 59.5 74.5 86.5 16.4 16.4 20 29.1 36.6 42.6 11.8 16.1 23.3 29.3 34.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 25 30 25 30 25 30 35 40 50 60 25 30 25 30 30 35 35 45 60 60 15 15 15 15 15 20 20 20 30 30 15 15 15 20 25 25 30 35 30 35 35 40 50 60 60 70 30 35 30 35 35 45 60 60 70 80 15 15 15 20 20 20 30 30 35 40 15 15 15 20 25 25 30 30 35 45 35 45 40 45 50 60 60 70 70 80 35 45 35 45 40 45 60 60 70 80 80 90 20 20 20 20 20 20 30 30 35 40 40 45 15 15 15 20 25 25 30 30 35 35 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 136 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078-150 Standard Motor - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.0 5.5 0.0 230 9.3 68 14.5 1.5 6.0 5.5 0.0 460 4.9 34 7.7 0.8 3.0 2.2 0.0 575 3.8 28 6 0.6 2.4 1.8 0.0 208 11.9 88 18.5 3.5 6.0 5.5 0.0 230 11.9 88 18.5 3.5 6.0 5.5 0.0 460 5.2 44 8.1 1.6 3.0 2.2 0.0 575 4.8 36 7.5 1.3 2.4 1.8 0.0 208 12.2 88 19 3.5 6.8 5.5 0.0 230 12.2 88 19 3.5 6.8 5.5 0.0 460 5.8 44 9 1.6 3.4 2.2 0.0 575 4.4 36 5.5 1.3 2.7 1.8 0.0 078 (6.5) 090 (7.5) 102 (8.5) Johnson Controls Unitary Products Electric Heat Option Model kW Stages Amps None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 29.9 31.1 54.3 70 96 29.9 34.6 61.6 79.7 109.7 15.6 17.3 30.8 39.8 54.9 12.2 13.8 24.7 31.9 43.9 39.8 39.8 54.3 70 96 39.8 39.8 61.6 79.7 109.7 17.9 17.9 30.8 39.8 54.9 15.8 15.8 24.7 31.9 43.9 41.3 41.3 55.3 71 97 41.3 41.3 62.6 80.7 110.7 19.7 19.7 31.3 40.3 55.4 15.2 15.2 25 32.2 44.3 35.4 38 61.2 76.8 102.9 35.4 41.4 68.5 86.5 116.6 17.8 20 33.6 42.6 57.6 14 16.1 26.9 34.1 46.1 45.3 45.3 61.2 76.8 102.9 45.3 45.3 68.5 86.5 116.6 20.1 20.1 33.6 42.6 57.6 17.6 17.6 26.9 34.1 46.1 46.8 46.8 62.2 77.8 103.9 46.8 46.8 69.5 87.5 117.6 21.9 21.9 34.1 43.1 58.1 17 17 27.3 34.5 46.5 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 40 35 40 60 70 70 80 100 110 35 40 35 45 70 70 80 90 110 125 20 20 20 20 35 35 40 45 60 60 15 15 15 20 25 30 35 35 45 50 50 50 50 50 60 70 70 80 100 110 50 50 50 50 70 70 80 90 110 125 20 25 20 25 35 35 40 45 60 60 20 20 20 20 25 30 35 35 45 50 50 50 50 50 60 70 80 80 100 110 50 50 50 50 70 70 90 90 125 125 25 25 25 25 35 35 45 45 60 60 20 20 20 20 25 30 35 35 45 50 137 528150-YTG-T-0514 ZH078-150 Standard Motor - Without Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 3.5 6.8 5.5 0.0 230 16.0 110.0 24.9 3.5 6.8 5.5 0.0 460 7.8 52.0 12.1 1.6 3.4 2.2 0.0 575 5.7 38.9 8.9 1.3 2.7 1.8 0.0 208 23.1 160 36 1.5 9.6 5.5 0.0 230 23.1 160 36 1.5 9.6 5.5 0.0 460 12.2 87 19 0.8 4.8 2.2 0.0 575 8.7 62 13.5 0.6 3.9 1.8 0.0 120 (10) 150 (12.5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 49.8 55.3 71.0 97.0 149.4 49.8 62.6 80.7 110.7 138.4 24.2 31.3 40.3 55.4 69.2 18.1 25.0 32.2 44.3 55.3 67.6 67.6 74.5 100.5 152.9 67.6 67.6 84.2 114.2 141.9 35.5 35.5 42.1 57.1 71 25.9 26.5 33.7 45.8 56.8 55.3 62.2 77.8 103.9 156.2 55.3 69.5 87.5 117.6 145.3 26.4 34.1 43.1 58.1 72.0 19.9 27.3 34.5 46.5 57.6 73.1 73.1 81.3 107.4 159.7 73.1 73.1 91 121.1 148.8 37.7 37.7 44.8 59.9 73.7 27.7 28.8 36 48 59.1 1 Model kW Stages Amps None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 60 70 60 70 80 80 100 110 150 175 60 70 70 70 90 90 125 125 150 175 30 30 35 35 45 45 60 60 80 80 20 25 25 30 35 35 45 50 60 60 90 90 90 90 90 90 110 110 175 175 90 90 90 90 90 100 125 125 175 175 45 45 45 45 45 45 60 60 80 80 30 35 30 35 35 40 50 50 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 138 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.1 68 14.2 1.5 6.0 5.5 0.0 230 9.1 68 14.2 1.5 6.0 5.5 0.0 460 4.5 34 7 0.8 3.0 2.2 0.0 575 3.8 28 6 0.6 2.4 1.8 0.0 208 11.2 88 17.5 1.5 6.0 5.5 0.0 230 11.2 88 17.5 1.5 6.0 5.5 0.0 460 5.6 44 8.0 0.8 3.0 2.2 0.0 575 4.5 36 7.0 0.6 2.4 1.8 0.0 208 14.1 88 22 1.5 6.8 5.5 0.0 230 14.1 88 22 1.5 6.8 5.5 0.0 460 7.7 55 12 0.8 3.4 2.2 0.0 575 5.1 36 7.5 0.6 2.7 1.8 0.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 18.9 18.9 23.1 31.1 46.7 18.9 18.9 25.5 34.6 52.6 9.4 9.4 12.8 17.3 26.3 7.8 13.8 21 21.5 23.1 31.1 46.7 59.5 21.5 25.5 34.6 52.6 67.6 10.8 12.8 17.3 26.3 33.8 8.6 13.8 21 27.1 27.4 27.4 32.1 47.7 60.5 71 27.4 27.4 35.6 53.6 68.6 80.7 14.6 14.6 17.8 26.8 34.3 40.3 10.3 14.2 21.4 27.4 32.2 24.4 24.4 30 38 53.6 24.4 24.4 32.4 41.4 59.5 11.6 11.6 15.5 20 29.1 9.6 16.1 23.3 27 30 38 53.6 66.4 27 32.4 41.4 59.5 74.5 13 15.5 20 29.1 36.6 10.4 16.1 23.3 29.3 32.9 32.9 39 54.6 67.4 77.8 32.9 33.4 42.4 60.5 75.5 87.5 16.8 16.8 20.5 29.6 37.1 43.1 12.1 16.5 23.7 29.7 34.5 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 25 30 25 30 25 30 35 40 50 60 25 30 25 30 30 35 35 45 60 60 15 15 15 15 15 20 20 20 30 30 15 15 15 20 25 25 30 35 30 35 35 40 50 60 60 70 30 35 30 35 35 45 60 60 70 80 15 15 15 20 20 20 30 30 35 40 15 15 15 20 25 25 30 30 35 45 35 45 40 45 50 60 70 70 80 80 35 45 35 45 40 45 60 70 70 80 90 90 20 20 20 20 20 25 30 30 35 40 45 45 15 15 15 20 25 25 30 30 35 35 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 139 528150-YTG-T-0514 ZH078-150 Hi Static Motor - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.8 5.5 0.0 230 9.3 68 14.5 1.5 6.8 5.5 0.0 460 4.9 34 7.7 0.8 3.4 2.2 0.0 575 3.8 28 6 0.6 2.7 1.8 0.0 208 11.9 88 18.5 3.5 9.6 5.5 0.0 230 11.9 88 18.5 3.5 9.6 5.5 0.0 460 5.2 44 8.1 1.6 4.8 2.2 0.0 575 4.8 36 7.5 1.3 3.9 1.8 0.0 208 12.2 88 19 3.5 9.6 5.5 0.0 230 12.2 88 19 3.5 9.6 5.5 0.0 460 5.8 44 9 1.6 4.8 2.2 0.0 575 4.4 36 5.5 1.3 3.9 1.8 0.0 078 (6.5) 090 (7.5) 102 (8.5) 140 Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 30.7 32.1 55.3 71 97 30.7 35.6 62.6 80.7 110.7 16 17.8 31.3 40.3 55.4 12.5 14.2 25 32.2 44.3 43.4 43.4 58.8 74.5 100.5 43.4 43.4 66.1 84.2 114.2 19.7 19.7 33.1 42.1 57.1 17.3 17.3 26.5 33.7 45.8 44.1 44.1 58.8 74.5 100.5 44.1 44.1 66.1 84.2 114.2 21.1 21.1 33.1 42.1 57.1 16.4 16.4 26.5 33.7 45.8 36.2 39 62.2 77.8 103.9 36.2 42.4 69.5 87.5 117.6 18.2 20.5 34.1 43.1 58.1 14.3 16.5 27.3 34.5 46.5 48.9 48.9 65.7 81.3 107.4 48.9 48.9 73 91 121.1 21.9 22.3 35.8 44.8 59.9 19.1 19.1 28.8 36 48 49.6 49.6 65.7 81.3 107.4 49.6 49.6 73 91 121.1 23.3 23.3 35.8 44.8 59.9 18.2 18.2 28.8 36 48 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 40 45 40 45 60 70 80 80 100 110 40 45 40 45 70 70 90 90 125 125 20 20 20 25 35 35 45 45 60 60 15 15 15 20 25 30 35 35 45 50 50 60 50 60 60 70 80 90 110 110 50 60 50 60 70 80 90 100 125 125 20 25 20 25 35 40 45 45 60 60 20 20 20 20 30 30 35 40 50 50 50 60 50 60 60 70 80 90 110 110 50 60 50 60 70 80 90 100 125 125 25 25 25 25 35 40 45 45 60 60 20 20 20 20 30 30 35 40 50 50 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 3.5 9.6 5.5 0.0 230 16.0 110.0 24.9 3.5 9.6 5.5 0.0 460 7.8 52.0 12.1 1.6 4.8 2.2 0.0 575 5.7 38.9 8.9 1.3 3.9 1.8 0.0 208 23.1 160 36 1.5 15.2 5.5 0.0 230 23.1 160 36 1.5 15.2 5.5 0.0 460 12.2 87 19 0.8 7.6 2.2 0.0 575 8.7 62 13.5 0.6 6.1 1.8 0.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA (Amps) MCA1 w/Pwr Exh (Amps) 52.6 58.8 74.5 100.5 152.9 52.6 66.1 84.2 114.2 141.9 25.6 33.1 42.1 57.1 71.0 19.3 26.5 33.7 45.8 56.8 73.2 73.2 81.5 107.5 159.9 73.2 73.2 91.2 121.2 148.9 38.3 38.3 45.6 60.6 74.5 28.1 29.3 36.5 48.5 59.6 58.1 65.7 81.3 107.4 159.7 58.1 73.0 91.0 121.1 148.8 27.8 35.8 44.8 59.9 73.7 21.1 28.8 36.0 48.0 59.1 78.7 78.7 88.3 114.4 166.7 78.7 80 98 128.1 155.8 40.5 40.5 48.3 63.4 77.2 29.9 31.5 38.7 50.8 61.8 1 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 60 70 60 70 80 90 110 110 175 175 60 70 70 80 90 100 125 125 175 175 30 35 35 40 45 45 60 60 80 80 25 25 30 30 35 40 50 50 70 70 90 100 90 100 90 100 110 125 175 175 90 100 90 100 100 100 125 150 175 175 50 50 50 50 50 50 70 70 90 90 35 35 35 35 40 40 50 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 141 528150-YTG-T-0514 ZH037-061 Standard Indoor Blower - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.1 68 14.2 1.5 6.0 5.5 10.0 230 9.1 68 14.2 1.5 6.0 5.5 10.0 460 4.5 34 7 0.8 3.0 2.2 5.0 575 3.8 28 6 0.6 2.4 1.8 4.0 208 11.2 88 17.5 1.5 6.0 5.5 10.0 230 11.2 88 17.5 1.5 6.0 5.5 10.0 460 5.6 44 8.0 0.8 3.0 2.2 5.0 575 4.5 36 7.0 0.6 2.4 1.8 4.0 208 14.1 88 22 1.5 6.0 5.5 10.0 230 14.1 88 22 1.5 6.0 5.5 10.0 460 7.7 55 12 0.8 3.0 2.2 5.0 575 5.1 36 7.5 0.6 2.4 1.8 4.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 29.1 29.1 35.6 43.6 59.2 29.1 29.1 38 47.1 65.1 14.6 14.6 19 23.5 32.6 11.8 18.8 26 31.5 35.6 43.6 59.2 72 31.5 38 47.1 65.1 80.1 15.8 19 23.5 32.6 40.1 12.6 18.8 26 32.1 36.6 36.6 43.6 59.2 72 82.5 36.6 38 47.1 65.1 80.1 92.2 19.2 19.2 23.5 32.6 40.1 46.1 14 18.8 26 32.1 36.9 34.6 34.9 42.5 50.5 66.1 34.6 35.9 44.9 53.9 72 16.8 17.3 21.8 26.3 35.3 13.6 21.1 28.3 37 42.5 50.5 66.1 78.9 37 44.9 53.9 72 87 18 21.8 26.3 35.3 42.8 14.4 21.1 28.3 34.3 42.1 42.5 50.5 66.1 78.9 89.3 42.1 44.9 53.9 72 87 99 21.4 21.8 26.3 35.3 42.8 48.8 15.8 21.1 28.3 34.3 39.1 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15.0 6.0 9.0 15.0 20.0 6.0 9.0 15.0 20.0 9.0 15.0 20.0 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 40 35 40 40 45 45 60 60 70 35 40 35 40 40 45 50 60 70 80 15 20 15 20 20 25 25 30 35 40 15 15 20 25 30 30 40 45 40 45 45 60 60 70 80 80 40 45 40 45 50 60 70 80 90 90 20 20 20 25 25 30 35 40 45 45 15 15 20 25 30 30 35 35 50 50 50 50 50 60 60 70 80 80 90 90 50 50 50 50 50 60 70 80 90 90 100 100 25 25 25 25 25 30 35 40 45 45 50 50 15 20 20 25 30 30 35 35 40 40 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 142 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078-150 Standard Motor - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.0 5.5 10.0 230 9.3 68 14.5 1.5 6.0 5.5 10.0 460 4.9 34 7.7 0.8 3.0 2.2 5.0 575 3.8 28 6 0.6 2.4 1.8 4.0 208 11.9 88 18.5 3.5 6.0 5.5 10.0 230 11.9 88 18.5 3.5 6.0 5.5 10.0 460 5.2 44 8.1 1.6 3.0 2.2 5.0 575 4.8 36 7.5 1.3 2.4 1.8 4.0 208 12.2 88 19 3.5 6.8 5.5 10.0 230 12.2 88 19 3.5 6.8 5.5 10.0 460 5.8 44 9 1.6 3.4 2.2 5.0 575 4.4 36 5.5 1.3 2.7 1.8 4.0 078 (6.5) 090 (7.5) 102 (8.5) Johnson Controls Unitary Products Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 40.1 43.6 66.8 82.5 108.5 40.1 47.1 74.1 92.2 122.2 20.7 23.5 37.1 46.1 61.1 16.2 18.8 29.7 36.9 48.9 49.8 49.8 66.8 82.5 108.5 49.8 49.8 74.1 92.2 122.2 22.9 23.5 37.1 46.1 61.1 19.8 19.8 29.7 36.9 48.9 51.3 51.3 67.8 83.5 109.5 51.3 51.3 75.1 93.2 123.2 24.7 24.7 37.6 46.6 61.6 19.2 19.2 30 37.2 49.3 45.6 50.5 73.7 89.3 115.4 45.6 53.9 81 99 129.1 22.9 26.3 39.8 48.8 63.9 18 21.1 31.9 39.1 51.1 55.3 55.3 73.7 89.3 115.4 55.3 55.3 81 99 129.1 25.1 26.3 39.8 48.8 63.9 21.6 21.6 31.9 39.1 51.1 56.8 56.8 74.7 90.3 116.4 56.8 56.8 82 100 130.1 26.9 26.9 40.3 49.3 64.4 21 21.5 32.3 39.5 51.5 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 50 50 50 60 70 80 90 90 110 125 50 50 50 60 80 90 100 100 125 150 25 25 25 30 40 40 50 50 70 70 20 20 20 25 30 35 40 40 50 60 60 60 60 60 70 80 90 90 110 125 60 60 60 60 80 90 100 100 125 150 25 30 25 30 40 40 50 50 70 70 20 25 20 25 30 35 40 40 50 60 60 60 60 60 70 80 90 100 110 125 60 60 60 60 80 90 100 100 125 150 30 30 30 30 40 45 50 50 70 70 20 25 20 25 30 35 40 40 50 60 143 528150-YTG-T-0514 ZH078-150 Standard Motor - With Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 3.5 6.8 5.5 10.0 230 16.0 110.0 24.9 3.5 6.8 5.5 10.0 460 7.8 52.0 12.1 1.6 3.4 2.2 5.0 575 5.7 38.9 8.9 1.3 2.7 1.8 4.0 208 23.1 160 36 1.5 9.6 5.5 10.0 230 23.1 160 36 1.5 9.6 5.5 10.0 460 12.2 87 19 0.8 4.8 2.2 5.0 575 8.7 62 13.5 0.6 3.9 1.8 4.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA (Amps) MCA1 w/Pwr Exh (Amps) 59.8 67.8 83.5 109.5 161.9 59.8 75.1 93.2 123.2 150.9 29.2 37.6 46.6 61.6 75.5 22.1 30.0 37.2 49.3 60.3 77.6 77.6 87 113 165.4 77.6 78.6 96.7 126.7 154.4 40.5 40.5 48.3 63.4 77.2 29.9 31.5 38.7 50.8 61.8 65.3 74.7 90.3 116.4 168.7 65.3 82.0 100.0 130.1 157.8 31.4 40.3 49.3 64.4 78.2 23.9 32.3 39.5 51.5 62.6 83.1 83.1 93.8 119.9 172.2 83.1 85.5 103.5 133.6 161.3 42.7 42.7 51.1 66.1 80 31.7 33.8 41 53 64.1 1 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 70 80 70 80 90 100 110 125 175 175 70 80 80 90 100 100 125 150 175 175 35 35 40 45 50 50 70 70 80 90 25 25 30 35 40 40 50 60 70 70 100 100 100 100 100 100 125 125 175 175 100 100 100 100 100 110 150 150 175 175 50 50 50 50 50 60 70 70 90 90 35 40 35 40 40 45 60 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 144 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH037-061 Hi Static Indoor Blower - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.1 68 14.2 1.5 6.0 5.5 10.0 230 9.1 68 14.2 1.5 6.0 5.5 10.0 460 4.5 34 7 0.8 3.0 2.2 5.0 575 3.8 28 6 0.6 2.4 1.8 4.0 208 11.2 88 17.5 1.5 6.0 5.5 10.0 230 11.2 88 17.5 1.5 6.0 5.5 10.0 460 5.6 44 8.0 0.8 3.0 2.2 5.0 575 4.5 36 7.0 0.6 2.4 1.8 4.0 208 14.1 88 22 1.5 6.8 5.5 10.0 230 14.1 88 22 1.5 6.8 5.5 10.0 460 7.7 55 12 0.8 3.4 2.2 5.0 575 5.1 36 7.5 0.6 2.7 1.8 4.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 29.1 29.1 35.6 43.6 59.2 29.1 29.1 38 47.1 65.1 14.6 14.6 19 23.5 32.6 11.8 18.8 26 31.5 35.6 43.6 59.2 72 31.5 38 47.1 65.1 80.1 15.8 19 23.5 32.6 40.1 12.6 18.8 26 32.1 37.4 37.4 44.6 60.2 73 83.5 37.4 39 48.1 66.1 81.1 93.2 19.6 19.6 24 33.1 40.6 46.6 14.3 19.2 26.4 32.4 37.2 34.6 34.9 42.5 50.5 66.1 34.6 35.9 44.9 53.9 72 16.8 17.3 21.8 26.3 35.3 13.6 21.1 28.3 37 42.5 50.5 66.1 78.9 37 44.9 53.9 72 87 18 21.8 26.3 35.3 42.8 14.4 21.1 28.3 34.3 42.9 43.5 51.5 67.1 79.9 90.3 42.9 45.9 54.9 73 88 100 21.8 22.3 26.8 35.8 43.3 49.3 16.1 21.5 28.7 34.7 39.5 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3.0 6.0 9.0 15.0 3.0 6.0 9.0 15.0 9.0 15.0 4.5 6.8 11.3 15.0 6.0 9.0 15.0 20.0 6.0 9.0 15.0 20.0 9.0 15.0 20.0 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 40 35 40 40 45 45 60 60 70 35 40 35 40 40 45 50 60 70 80 15 20 15 20 20 25 25 30 35 40 15 15 20 25 30 30 40 45 40 45 45 60 60 70 80 80 40 45 40 45 50 60 70 80 90 90 20 20 20 25 25 30 35 40 45 45 15 15 20 25 30 30 35 35 50 50 50 50 50 60 70 70 80 80 90 100 50 50 50 50 50 60 70 80 90 90 100 100 25 25 25 25 25 30 35 40 45 45 50 50 15 20 20 25 30 30 35 35 40 40 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 145 528150-YTG-T-0514 ZH078-150 Hi Static Motor - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.8 5.5 10.0 230 9.3 68 14.5 1.5 6.8 5.5 10.0 460 4.9 34 7.7 0.8 3.4 2.2 5.0 575 3.8 28 6 0.6 2.7 1.8 4.0 208 11.9 88 18.5 3.5 9.6 5.5 10.0 230 11.9 88 18.5 3.5 9.6 5.5 10.0 460 5.2 44 8.1 1.6 4.8 2.2 5.0 575 4.8 36 7.5 1.3 3.9 1.8 4.0 208 12.2 88 19 3.5 9.6 5.5 10.0 230 12.2 88 19 3.5 9.6 5.5 10.0 460 5.8 44 9 1.6 4.8 2.2 5.0 575 4.4 36 5.5 1.3 3.9 1.8 4.0 078 (6.5) 090 (7.5) 102 (8.5) 146 Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 40.9 44.6 67.8 83.5 109.5 40.9 48.1 75.1 93.2 123.2 21.1 24 37.6 46.6 61.6 16.5 19.2 30 37.2 49.3 53.4 53.4 71.3 87 113 53.4 53.4 78.6 96.7 126.7 24.7 25.8 39.3 48.3 63.4 21.3 21.3 31.5 38.7 50.8 54.1 54.1 71.3 87 113 54.1 54.1 78.6 96.7 126.7 26.1 26.1 39.3 48.3 63.4 20.4 20.7 31.5 38.7 50.8 46.4 51.5 74.7 90.3 116.4 46.4 54.9 82 100 130.1 23.3 26.8 40.3 49.3 64.4 18.3 21.5 32.3 39.5 51.5 58.9 58.9 78.2 93.8 119.9 58.9 58.9 85.5 103.5 133.6 26.9 28.5 42.1 51.1 66.1 23.1 23.1 33.8 41 53 59.6 59.6 78.2 93.8 119.9 59.6 59.6 85.5 103.5 133.6 28.3 28.5 42.1 51.1 66.1 22.2 23 33.8 41 53 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 50 50 50 60 70 80 90 100 110 125 50 50 50 60 80 90 100 100 125 150 25 25 25 30 40 45 50 50 70 70 20 20 20 25 30 35 40 40 50 60 60 70 60 70 80 80 90 100 125 125 60 70 60 70 80 90 100 110 150 150 25 30 30 30 40 45 50 60 70 70 25 25 25 25 35 35 40 45 60 60 60 70 60 70 80 80 90 100 125 125 60 70 60 70 80 90 100 110 150 150 30 30 30 30 40 45 50 60 70 70 25 25 25 25 35 35 40 45 60 60 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH078-150 Hi Static Motor - With Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 3.5 9.6 5.5 10.0 230 16.0 110.0 24.9 3.5 9.6 5.5 10.0 460 7.8 52.0 12.1 1.6 4.8 2.2 5.0 575 5.7 38.9 8.9 1.3 3.9 1.8 4.0 208 23.1 160 36 1.5 15.2 5.5 10.0 230 23.1 160 36 1.5 15.2 5.5 10.0 460 12.2 87 19 0.8 7.6 2.2 5.0 575 8.7 62 13.5 0.6 6.1 1.8 4.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA (Amps) MCA1 w/Pwr Exh (Amps) 62.6 71.3 87.0 113.0 165.4 62.6 78.6 96.7 126.7 154.4 30.6 39.3 48.3 63.4 77.2 23.3 31.5 38.7 50.8 61.8 83.2 83.2 94 120 172.4 83.2 85.6 103.7 133.7 161.4 43.3 43.3 51.8 66.9 80.7 32.1 34.3 41.5 53.5 64.6 68.1 78.2 93.8 119.9 172.2 68.1 85.5 103.5 133.6 161.3 32.8 42.1 51.1 66.1 80.0 25.1 33.8 41.0 53.0 64.1 88.7 88.7 100.8 126.9 179.2 88.7 92.5 110.5 140.6 168.3 45.5 45.6 54.6 69.6 83.5 33.9 36.5 43.7 55.8 66.8 1 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 70 80 80 80 90 100 125 125 175 175 70 80 80 90 100 110 150 150 175 175 35 40 40 45 50 60 70 70 90 90 25 30 35 35 40 45 60 60 70 70 100 110 100 110 100 110 125 150 175 200 100 110 100 110 110 125 150 150 175 175 50 50 50 50 60 60 70 70 90 90 40 40 40 40 45 45 60 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 147 528150-YTG-T-0514 ZJ037-061 Standard Indoor Blower - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 0.0 230 8.7 68 13.5 1.5 6.0 5.5 0.0 460 4.6 34 7.1 0.8 3.0 2.2 0.0 575 3.5 28 5.5 0.6 2.4 1.8 0.0 208 11.2 88 17.5 1.5 6.0 5.5 0.0 230 11.2 88 17.5 1.5 6.0 5.5 0.0 460 5.6 44 8.0 0.8 3.0 2.2 0.0 575 4.5 36 7.0 0.6 2.4 1.8 0.0 208 14.1 88 22 1.5 6.0 5.5 0.0 230 14.1 88 22 1.5 6.0 5.5 0.0 460 7.7 55 12 0.8 3.0 2.2 0.0 575 5.1 36 7.5 0.6 2.4 1.8 0.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 18.4 18.4 23.1 31.1 46.7 18.4 18.4 25.5 34.6 52.6 9.6 9.6 12.8 17.3 26.3 7.4 13.8 21 21.5 23.1 31.1 46.7 59.5 21.7 25.5 34.6 52.6 67.6 10.8 12.8 17.3 26.3 33.8 8.6 13.8 21 27.1 26.6 26.6 31.1 46.7 59.5 70 26.6 26.6 34.6 52.6 67.6 79.7 14.2 14.2 17.3 26.3 33.8 39.8 10 13.8 21 27.1 31.9 23.9 23.9 30 38 53.6 23.9 23.9 32.4 41.4 59.5 11.8 11.8 15.5 20 29.1 9.2 16.1 23.3 27 30 38 53.6 66.4 27 32.4 41.4 59.5 74.5 13 15.5 20 29.1 36.6 10.4 16.1 23.3 29.3 32.1 32.1 38 53.6 66.4 76.8 32.1 32.4 41.4 59.5 74.5 86.5 16.4 16.4 20 29.1 36.6 42.6 11.8 16.1 23.3 29.3 34.1 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 25 30 25 30 25 30 35 40 50 60 25 30 25 30 30 35 35 45 60 60 15 15 15 15 15 20 20 20 30 30 15 15 15 20 25 25 30 35 30 35 35 40 50 60 60 70 30 35 30 35 35 45 60 60 70 80 15 15 15 20 20 20 30 30 35 40 15 15 15 20 25 25 30 30 35 45 35 45 40 45 50 60 60 70 70 80 35 45 35 45 40 45 60 60 70 80 80 90 20 20 20 20 20 20 30 30 35 40 40 45 15 15 15 20 25 25 30 30 35 35 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 148 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078-150 Standard Motor - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.0 5.5 0.0 230 9.3 68 14.5 1.5 6.0 5.5 0.0 460 4.9 34 7.6 0.8 3.0 2.2 0.0 575 3.8 28 6 0.6 2.4 1.8 0.0 208 11.9 88 18.5 3.5 6.0 5.5 0.0 230 11.9 88 18.5 3.5 6.0 5.5 0.0 460 5.2 44 8.1 1.6 3.0 2.2 0.0 575 4.8 36 7.5 1.3 2.4 1.8 0.0 208 12.2 88 19 3.5 6.8 5.5 0.0 230 12.2 88 19 3.5 6.8 5.5 0.0 460 5.8 44 9 1.6 3.4 2.2 0.0 575 4.4 36 5.5 1.3 2.7 1.8 0.0 078 (6.5) 090 (7.5) 102 (8.5) Johnson Controls Unitary Products Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 29.9 31.1 54.3 70 96 29.9 34.6 61.6 79.7 109.7 15.6 17.3 30.8 39.8 54.9 12.2 13.8 24.7 31.9 43.9 39.8 39.8 54.3 70 96 39.8 39.8 61.6 79.7 109.7 17.9 17.9 30.8 39.8 54.9 15.8 15.8 24.7 31.9 43.9 41.3 41.3 55.3 71 97 41.3 41.3 62.6 80.7 110.7 19.7 19.7 31.3 40.3 55.4 15.2 15.2 25 32.2 44.3 35.4 38 61.2 76.8 102.9 35.4 41.4 68.5 86.5 116.6 17.8 20 33.6 42.6 57.6 14 16.1 26.9 34.1 46.1 45.3 45.3 61.2 76.8 102.9 45.3 45.3 68.5 86.5 116.6 20.1 20.1 33.6 42.6 57.6 17.6 17.6 26.9 34.1 46.1 46.8 46.8 62.2 77.8 103.9 46.8 46.8 69.5 87.5 117.6 21.9 21.9 34.1 43.1 58.1 17 17 27.3 34.5 46.5 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 35 40 35 40 60 70 70 80 100 110 35 40 35 45 70 70 80 90 110 125 20 20 20 20 35 35 40 45 60 60 15 15 15 20 25 30 35 35 45 50 50 50 50 50 60 70 70 80 100 110 50 50 50 50 70 70 80 90 110 125 20 25 20 25 35 35 40 45 60 60 20 20 20 20 25 30 35 35 45 50 50 50 50 50 60 70 80 80 100 110 50 50 50 50 70 70 90 90 125 125 25 25 25 25 35 35 45 45 60 60 20 20 20 20 25 30 35 35 45 50 149 528150-YTG-T-0514 ZJ078-150 Standard Motor - Without Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16 110 24.9 3.5 6.8 5.5 0.0 230 16 110 24.9 3.5 6.8 5.5 0.0 460 7.8 52 12.1 1.6 3.4 2.2 0.0 575 5.7 38.9 8.9 1.3 2.7 1.8 0.0 208 23.1 160 36 1.5 9.6 5.5 0.0 230 23.1 160 36 1.5 9.6 5.5 0.0 460 12.2 87 19 0.8 4.8 2.2 0.0 575 8.7 62 13.5 0.6 3.9 1.8 0.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA (Amps) MCA1 w/Pwr Exh (Amps) 49.8 55.3 71 97 149.4 49.8 62.6 80.7 110.7 138.4 24.2 31.3 40.3 55.4 69.2 18.1 25 32.2 44.3 55.3 67.6 67.6 74.5 100.5 152.9 67.6 67.6 84.2 114.2 141.9 35.5 35.5 42.1 57.1 71 25.9 26.5 33.7 45.8 56.8 55.3 62.2 77.8 103.9 156.2 55.3 69.5 87.5 117.6 145.3 26.4 34.1 43.1 58.1 72 19.9 27.3 34.5 46.5 57.6 73.1 73.1 81.3 107.4 159.7 73.1 73.1 91 121.1 148.8 37.7 37.7 44.8 59.9 73.7 27.7 28.8 36 48 59.1 1 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 60 70 60 70 80 80 100 110 150 175 60 70 70 70 90 90 125 125 150 175 30 30 35 35 45 45 60 60 80 80 20 25 25 30 35 35 45 50 60 60 90 90 90 90 90 90 110 110 175 175 90 90 90 90 90 100 125 125 175 175 45 45 45 45 45 45 60 60 80 80 30 35 30 35 35 40 50 50 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 150 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 0.0 230 8.7 68 13.5 1.5 6.0 5.5 0.0 460 4.6 34 7.1 0.8 3.0 2.2 0.0 575 3.5 28 5.5 0.6 2.4 1.8 0.0 208 11.2 88 17.5 1.5 6.0 5.5 0.0 230 11.2 88 17.5 1.5 6.0 5.5 0.0 460 5.6 44 8.0 0.8 3.0 2.2 0.0 575 4.5 36 7.0 0.6 2.4 1.8 0.0 208 14.1 88 22 1.5 6.8 5.5 0.0 230 14.1 88 22 1.5 6.8 5.5 0.0 460 7.7 55 12 0.8 3.4 2.2 0.0 575 5.1 36 7.5 0.6 2.7 1.8 0.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 18.4 18.4 23.1 31.1 46.7 18.4 18.4 25.5 34.6 52.6 9.6 9.6 12.8 17.3 26.3 7.4 13.8 21 21.5 23.1 31.1 46.7 59.5 21.5 25.5 34.6 52.6 67.6 10.8 12.8 17.3 26.3 33.8 8.6 13.8 21 27.1 27.4 27.4 32.1 47.7 60.5 71 27.4 27.4 35.6 53.6 68.6 80.7 14.6 14.6 17.8 26.8 34.3 40.3 10.3 14.2 21.4 27.4 32.2 23.9 23.9 30 38 53.6 23.9 23.9 32.4 41.4 59.5 11.8 11.8 15.5 20 29.1 9.2 16.1 23.3 27 30 38 53.6 66.4 27 32.4 41.4 59.5 74.5 13 15.5 20 29.1 36.6 10.4 16.1 23.3 29.3 32.9 32.9 39 54.6 67.4 77.8 32.9 33.4 42.4 60.5 75.5 87.5 16.8 16.8 20.5 29.6 37.1 43.1 12.1 16.5 23.7 29.7 34.5 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 25 30 25 30 25 30 35 40 50 60 25 30 25 30 30 35 35 45 60 60 15 15 15 15 15 20 20 20 30 30 15 15 15 20 25 25 30 35 30 35 35 40 50 60 60 70 30 35 30 35 35 45 60 60 70 80 15 15 15 20 20 20 30 30 35 40 15 15 15 20 25 25 30 30 35 45 35 45 40 45 50 60 70 70 80 80 35 45 35 45 40 45 60 70 70 80 90 90 20 20 20 20 20 25 30 30 35 40 45 45 15 15 15 20 25 25 30 30 35 35 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 151 528150-YTG-T-0514 ZJ078-150 Hi Static Motor - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.8 5.5 0.0 230 9.3 68 14.5 1.5 6.8 5.5 0.0 460 4.9 34 7.6 0.8 3.4 2.2 0.0 575 3.8 28 6 0.6 2.7 1.8 0.0 208 11.9 88 18.5 3.5 9.6 5.5 0.0 230 11.9 88 18.5 3.5 9.6 5.5 0.0 460 5.2 44 8.1 1.6 4.8 2.2 0.0 575 4.8 36 7.5 1.3 3.9 1.8 0.0 208 12.2 88 19 3.5 9.6 5.5 0.0 230 12.2 88 19 3.5 9.6 5.5 0.0 460 5.8 44 9 1.6 4.8 2.2 0.0 575 4.4 36 5.5 1.3 3.9 1.8 0.0 078 (6.5) 090 (7.5) 102 (8.5) 152 Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 30.7 32.1 55.3 71 97 30.7 35.6 62.6 80.7 110.7 16 17.8 31.3 40.3 55.4 12.5 14.2 25 32.2 44.3 43.4 43.4 58.8 74.5 100.5 43.4 43.4 66.1 84.2 114.2 19.7 19.7 33.1 42.1 57.1 17.3 17.3 26.5 33.7 45.8 44.1 44.1 58.8 74.5 100.5 44.1 44.1 66.1 84.2 114.2 21.1 21.1 33.1 42.1 57.1 16.4 16.4 26.5 33.7 45.8 36.2 39 62.2 77.8 103.9 36.2 42.4 69.5 87.5 117.6 18.2 20.5 34.1 43.1 58.1 14.3 16.5 27.3 34.5 46.5 48.9 48.9 65.7 81.3 107.4 48.9 48.9 73 91 121.1 21.9 22.3 35.8 44.8 59.9 19.1 19.1 28.8 36 48 49.6 49.6 65.7 81.3 107.4 49.6 49.6 73 91 121.1 23.3 23.3 35.8 44.8 59.9 18.2 18.2 28.8 36 48 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 40 45 40 45 60 70 80 80 100 110 40 45 40 45 70 70 90 90 125 125 20 20 20 25 35 35 45 45 60 60 15 15 15 20 25 30 35 35 45 50 50 60 50 60 60 70 80 90 110 110 50 60 50 60 70 80 90 100 125 125 20 25 20 25 35 40 45 45 60 60 20 20 20 20 30 30 35 40 50 50 50 60 50 60 60 70 80 90 110 110 50 60 50 60 70 80 90 100 125 125 25 25 25 25 35 40 45 45 60 60 20 20 20 20 30 30 35 40 50 50 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16 110 24.9 3.5 9.6 5.5 0.0 230 16 110 24.9 3.5 9.6 5.5 0.0 460 7.8 52 12.1 1.6 4.8 2.2 0.0 575 5.7 38.9 8.9 1.3 3.9 1.8 0.0 208 23.1 160 36 1.5 15.2 5.5 0.0 230 23.1 160 36 1.5 15.2 5.5 0.0 460 12.2 87 19 0.8 7.6 2.2 0.0 575 8.7 62 13.5 0.6 6.1 1.8 0.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 52.6 58.8 74.5 100.5 152.9 52.6 66.1 84.2 114.2 141.9 25.6 33.1 42.1 57.1 71 19.3 26.5 33.7 45.8 56.8 73.2 73.2 81.5 107.5 159.9 73.2 73.2 91.2 121.2 148.9 38.3 38.3 45.6 60.6 74.5 28.1 29.3 36.5 48.5 59.6 58.1 65.7 81.3 107.4 159.7 58.1 73 91 121.1 148.8 27.8 35.8 44.8 59.9 73.7 21.1 28.8 36 48 59.1 78.7 78.7 88.3 114.4 166.7 78.7 80 98 128.1 155.8 40.5 40.5 48.3 63.4 77.2 29.9 31.5 38.7 50.8 61.8 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 60 70 60 70 80 90 110 110 175 175 60 70 70 80 90 100 125 125 175 175 30 35 35 40 45 45 60 60 80 80 25 25 30 30 35 40 50 50 70 70 90 100 90 100 90 100 110 125 175 175 90 100 90 100 100 100 125 150 175 175 50 50 50 50 50 50 70 70 90 90 35 35 35 35 40 40 50 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 153 528150-YTG-T-0514 ZJ037-061 Standard Indoor Blower - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 10.0 230 8.7 68 13.5 1.5 6.0 5.5 10.0 460 4.6 34 7.1 0.8 3.0 2.2 5.0 575 3.5 28 5.5 0.6 2.4 1.8 4.0 208 11.2 88 17.5 1.5 6.0 5.5 10.0 230 11.2 88 17.5 1.5 6.0 5.5 10.0 460 5.6 44 8.0 0.8 3.0 2.2 5.0 575 4.5 36 7.0 0.6 2.4 1.8 4.0 208 14.1 88 22 1.5 6.0 5.5 10.0 230 14.1 88 22 1.5 6.0 5.5 10.0 460 7.7 55 12 0.8 3.0 2.2 5.0 575 5.1 36 7.5 0.6 2.4 1.8 4.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 28.7 28.7 35.6 43.6 59.2 28.7 29 38 47.1 65.1 14.7 14.7 19 23.5 32.6 11.5 18.8 26 31.5 35.6 43.6 59.2 72 31.5 38 47.1 65.1 80.1 15.8 19 23.5 32.6 40.1 12.6 18.8 26 32.1 36.6 36.6 43.6 59.2 72 82.5 36.6 38 47.1 65.1 80.1 92.2 19.2 19.2 23.5 32.6 40.1 46.1 14 18.8 26 32.1 36.9 34.2 34.9 42.5 50.5 66.1 34.2 35.9 44.9 53.9 72 16.9 17.3 21.8 26.3 35.3 13.3 21.1 28.3 37 42.5 50.5 66.1 78.9 37 44.9 53.9 72 87 18 21.8 26.3 35.3 42.8 14.4 21.1 28.3 34.3 42.1 42.5 50.5 66.1 78.9 89.3 42.1 44.9 53.9 72 87 99 21.4 21.8 26.3 35.3 42.8 48.8 15.8 21.1 28.3 34.3 39.1 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15.0 6.0 9.0 15.0 20.0 6.0 9.0 15.0 20.0 9.0 15.0 20.0 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 40 35 40 40 45 45 60 60 70 35 40 35 40 40 45 50 60 70 80 15 20 15 20 20 25 25 30 35 40 15 15 20 25 30 30 40 45 40 45 45 60 60 70 80 80 40 45 40 45 50 60 70 80 90 90 20 20 20 25 25 30 35 40 45 45 15 15 20 25 30 30 35 35 50 50 50 50 50 60 60 70 80 80 90 90 50 50 50 50 50 60 70 80 90 90 100 100 25 25 25 25 25 30 35 40 45 45 50 50 15 20 20 25 30 30 35 35 40 40 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 154 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078-150 Standard Motor - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.0 5.5 10.0 230 9.3 68 14.5 1.5 6.0 5.5 10.0 460 4.9 34 7.6 0.8 3.0 2.2 5.0 575 3.8 28 6 0.6 2.4 1.8 4.0 208 11.9 88 18.5 3.5 6.0 5.5 10.0 230 11.9 88 18.5 3.5 6.0 5.5 10.0 460 5.2 44 8.1 1.6 3.0 2.2 5.0 575 4.8 36 7.5 1.3 2.4 1.8 4.0 208 12.2 88 19 3.5 6.8 5.5 10.0 230 12.2 88 19 3.5 6.8 5.5 10.0 460 5.8 44 9 1.6 3.4 2.2 5.0 575 4.4 36 5.5 1.3 2.7 1.8 4.0 078 (6.5) 090 (7.5) 102 (8.5) Johnson Controls Unitary Products Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 40.1 43.6 66.8 82.5 108.5 40.1 47.1 74.1 92.2 122.2 20.7 23.5 37.1 46.1 61.1 16.2 18.8 29.7 36.9 48.9 49.8 49.8 66.8 82.5 108.5 49.8 49.8 74.1 92.2 122.2 22.9 23.5 37.1 46.1 61.1 19.8 19.8 29.7 36.9 48.9 51.3 51.3 67.8 83.5 109.5 51.3 51.3 75.1 93.2 123.2 24.7 24.7 37.6 46.6 61.6 19.2 19.2 30 37.2 49.3 45.6 50.5 73.7 89.3 115.4 45.6 53.9 81 99 129.1 22.9 26.3 39.8 48.8 63.9 18 21.1 31.9 39.1 51.1 55.3 55.3 73.7 89.3 115.4 55.3 55.3 81 99 129.1 25.1 26.3 39.8 48.8 63.9 21.6 21.6 31.9 39.1 51.1 56.8 56.8 74.7 90.3 116.4 56.8 56.8 82 100 130.1 26.9 26.9 40.3 49.3 64.4 21 21.5 32.3 39.5 51.5 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 50 50 50 60 70 80 90 90 110 125 50 50 50 60 80 90 100 100 125 150 25 25 25 30 40 40 50 50 70 70 20 20 20 25 30 35 40 40 50 60 60 60 60 60 70 80 90 90 110 125 60 60 60 60 80 90 100 100 125 150 25 30 25 30 40 40 50 50 70 70 20 25 20 25 30 35 40 40 50 60 60 60 60 60 70 80 90 100 110 125 60 60 60 60 80 90 100 100 125 150 30 30 30 30 40 45 50 50 70 70 20 25 20 25 30 35 40 40 50 60 155 528150-YTG-T-0514 ZJ078-150 Standard Motor - With Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16 110 24.9 3.5 6.8 5.5 10.0 230 16 110 24.9 3.5 6.8 5.5 10.0 460 7.8 52 12.1 1.6 3.4 2.2 5.0 575 5.7 38.9 8.9 1.3 2.7 1.8 4.0 208 23.1 160 36 1.5 9.6 5.5 10.0 230 23.1 160 36 1.5 9.6 5.5 10.0 460 12.2 87 19 0.8 4.8 2.2 5.0 575 8.7 62 13.5 0.6 3.9 1.8 4.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA (Amps) MCA1 w/Pwr Exh (Amps) 59.8 67.8 83.5 109.5 161.9 59.8 75.1 93.2 123.2 150.9 29.2 37.6 46.6 61.6 75.5 22.1 30 37.2 49.3 60.3 77.6 77.6 87 113 165.4 77.6 78.6 96.7 126.7 154.4 40.5 40.5 48.3 63.4 77.2 29.9 31.5 38.7 50.8 61.8 65.3 74.7 90.3 116.4 168.7 65.3 82 100 130.1 157.8 31.4 40.3 49.3 64.4 78.2 23.9 32.3 39.5 51.5 62.6 83.1 83.1 93.8 119.9 172.2 83.1 85.5 103.5 133.6 161.3 42.7 42.7 51.1 66.1 80 31.7 33.8 41 53 64.1 1 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 70 80 70 80 90 100 110 125 175 175 70 80 80 90 100 100 125 150 175 175 35 35 40 45 50 50 70 70 80 90 25 25 30 35 40 40 50 60 70 70 100 100 100 100 100 100 125 125 175 175 100 100 100 100 100 110 150 150 175 175 50 50 50 50 50 60 70 70 90 90 35 40 35 40 40 45 60 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 156 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ037-061 Hi Static Blower - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 10.0 230 8.7 68 13.5 1.5 6.0 5.5 10.0 460 4.6 34 7.1 0.8 3.0 2.2 5.0 575 3.5 28 5.5 0.6 2.4 1.8 4.0 208 11.2 88 17.5 1.5 6.0 5.5 10.0 230 11.2 88 17.5 1.5 6.0 5.5 10.0 460 5.6 44 8.0 0.8 3.0 2.2 5.0 575 4.5 36 7.0 0.6 2.4 1.8 4.0 208 14.1 88 22 1.5 6.8 5.5 10.0 230 14.1 88 22 1.5 6.8 5.5 10.0 460 7.7 55 12 0.8 3.4 2.2 5.0 575 5.1 36 7.5 0.6 2.7 1.8 4.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 28.7 28.7 35.6 43.6 59.2 28.7 29 38 47.1 65.1 14.7 14.7 19 23.5 32.6 11.5 18.8 26 31.5 35.6 43.6 59.2 72 31.5 38 47.1 65.1 80.1 15.8 19 23.5 32.6 40.1 12.6 18.8 26 32.1 37.4 37.4 44.6 60.2 73 83.5 37.4 39 48.1 66.1 81.1 93.2 19.6 19.6 24 33.1 40.6 46.6 14.3 19.2 26.4 32.4 37.2 34.2 34.9 42.5 50.5 66.1 34.2 35.9 44.9 53.9 72 16.9 17.3 21.8 26.3 35.3 13.3 21.1 28.3 37 42.5 50.5 66.1 78.9 37 44.9 53.9 72 87 18 21.8 26.3 35.3 42.8 14.4 21.1 28.3 34.3 42.9 43.5 51.5 67.1 79.9 90.3 42.9 45.9 54.9 73 88 100 21.8 22.3 26.8 35.8 43.3 49.3 16.1 21.5 28.7 34.7 39.5 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15.0 6.0 9.0 15.0 20.0 6.0 9.0 15.0 20.0 9.0 15.0 20.0 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 40 35 40 40 45 45 60 60 70 35 40 35 40 40 45 50 60 70 80 15 20 15 20 20 25 25 30 35 40 15 15 20 25 30 30 40 45 40 45 45 60 60 70 80 80 40 45 40 45 50 60 70 80 90 90 20 20 20 25 25 30 35 40 45 45 15 15 20 25 30 30 35 35 50 50 50 50 50 60 70 70 80 80 90 100 50 50 50 50 50 60 70 80 90 90 100 100 25 25 25 25 25 30 35 40 45 45 50 50 15 20 20 25 30 30 35 35 40 40 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 157 528150-YTG-T-0514 ZJ078-150 Hi Static Motor - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 9.3 68 14.5 1.5 6.8 5.5 10.0 230 9.3 68 14.5 1.5 6.8 5.5 10.0 460 4.9 34 7.6 0.8 3.4 2.2 5.0 575 3.8 28 6 0.6 2.7 1.8 4.0 208 11.9 88 18.5 3.5 9.6 5.5 10.0 230 11.9 88 18.5 3.5 9.6 5.5 10.0 460 5.2 44 8.1 1.6 4.8 2.2 5.0 575 4.8 36 7.5 1.3 3.9 1.8 4.0 208 12.2 88 19 3.5 9.6 5.5 10.0 230 12.2 88 19 3.5 9.6 5.5 10.0 460 5.8 44 9 1.6 4.8 2.2 5.0 575 4.4 36 5.5 1.3 3.9 1.8 4.0 078 (6.5) 090 (7.5) 102 (8.5) 158 Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 6.8 13.5 18 25.5 9 18 24 34 9 18 24 34 9 18 24 34 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 40.9 44.6 67.8 83.5 109.5 40.9 48.1 75.1 93.2 123.2 21.1 24 37.6 46.6 61.6 16.5 19.2 30 37.2 49.3 53.4 53.4 71.3 87 113 53.4 53.4 78.6 96.7 126.7 24.7 25.8 39.3 48.3 63.4 21.3 21.3 31.5 38.7 50.8 54.1 54.1 71.3 87 113 54.1 54.1 78.6 96.7 126.7 26.1 26.1 39.3 48.3 63.4 20.4 20.7 31.5 38.7 50.8 46.4 51.5 74.7 90.3 116.4 46.4 54.9 82 100 130.1 23.3 26.8 40.3 49.3 64.4 18.3 21.5 32.3 39.5 51.5 58.9 58.9 78.2 93.8 119.9 58.9 58.9 85.5 103.5 133.6 26.9 28.5 42.1 51.1 66.1 23.1 23.1 33.8 41 53 59.6 59.6 78.2 93.8 119.9 59.6 59.6 85.5 103.5 133.6 28.3 28.5 42.1 51.1 66.1 22.2 23 33.8 41 53 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 50 50 50 60 70 80 90 100 110 125 50 50 50 60 80 90 100 100 125 150 25 25 25 30 40 45 50 50 70 70 20 20 20 25 30 35 40 40 50 60 60 70 60 70 80 80 90 100 125 125 60 70 60 70 80 90 100 110 150 150 25 30 30 30 40 45 50 60 70 70 25 25 25 25 35 35 40 45 60 60 60 70 60 70 80 80 90 100 125 125 60 70 60 70 80 90 100 110 150 150 30 30 30 30 40 45 50 60 70 70 25 25 25 25 35 35 40 45 60 60 Johnson Controls Unitary Products 528150-YTG-T-0514 ZJ078-150 Hi Static Motor - With Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16 110 24.9 3.5 9.6 5.5 10.0 230 16 110 24.9 3.5 9.6 5.5 10.0 460 7.8 52 12.1 1.6 4.8 2.2 5.0 575 5.7 38.9 8.9 1.3 3.9 1.8 4.0 208 23.1 160 36 1.5 15.2 5.5 10.0 230 23.1 160 36 1.5 15.2 5.5 10.0 460 12.2 87 19 0.8 7.6 2.2 5.0 575 8.7 62 13.5 0.6 6.1 1.8 4.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 13.5 18 25.5 40.6 18 24 34 54 18 24 34 54 18 24 34 54 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 62.6 71.3 87 113 165.4 62.6 78.6 96.7 126.7 154.4 30.6 39.3 48.3 63.4 77.2 23.3 31.5 38.7 50.8 61.8 83.2 83.2 94 120 172.4 83.2 85.6 103.7 133.7 161.4 43.3 43.3 51.8 66.9 80.7 32.1 34.3 41.5 53.5 64.6 68.1 78.2 93.8 119.9 172.2 68.1 85.5 103.5 133.6 161.3 32.8 42.1 51.1 66.1 80 25.1 33.8 41 53 64.1 88.7 88.7 100.8 126.9 179.2 88.7 92.5 110.5 140.6 168.3 45.5 45.6 54.6 69.6 83.5 33.9 36.5 43.7 55.8 66.8 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 70 80 80 80 90 100 125 125 175 175 70 80 80 90 100 110 150 150 175 175 35 40 40 45 50 60 70 70 90 90 25 30 35 35 40 45 60 60 70 70 100 110 100 110 100 110 125 150 175 200 100 110 100 110 110 125 150 150 175 175 50 50 50 50 60 60 70 70 90 90 40 40 40 40 45 45 60 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 159 528150-YTG-T-0514 ZR037-061 Standard Indoor Blower - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 0.0 230 8.7 68 13.5 1.5 6.0 5.5 0.0 460 4.6 34 7.1 0.8 3.0 2.2 0.0 575 3.5 28 5.5 0.6 2.4 1.8 0.0 208 11.9 88 18.5 1.5 6.0 5.5 0.0 230 11.9 88 18.5 1.5 6.0 5.5 0.0 460 5.2 44 8.1 0.8 3.0 2.2 0.0 575 4.8 36 7.5 0.6 2.4 1.8 0.0 208 14.1 88 22.0 1.5 4.3 5.5 0.0 230 14.1 88 22.0 1.5 4.3 5.5 0.0 460 7.7 55 12.0 0.8 2.1 2.2 0.0 575 5.1 36 7.5 0.6 2.0 1.8 0.0 037 (3) 049 (4) 061 (4) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 18.4 18.4 23.1 31.1 46.7 18.4 18.4 25.5 34.6 52.6 9.6 9.6 12.8 17.3 26.3 7.4 13.8 21.0 23.9 23.9 31.1 46.7 59.5 23.9 25.5 34.6 52.6 67.6 11.1 12.8 17.3 26.3 33.8 9.6 13.8 21.0 27.1 26.6 26.6 31.1 46.7 59.5 70.0 26.6 26.6 34.6 52.6 67.6 79.7 14.2 14.2 17.3 26.3 33.8 39.8 10.0 13.8 21.0 27.1 31.9 23.9 23.9 30.0 38.0 53.6 23.9 23.9 32.4 41.4 59.5 11.8 11.8 15.5 20.0 29.1 9.2 16.1 23.3 29.4 30.0 38.0 53.6 66.4 29.4 32.4 41.4 59.5 74.5 13.3 15.5 20.0 29.1 36.6 11.4 16.1 23.3 29.3 32.1 32.1 38.0 53.6 66.4 76.8 32.1 32.4 41.4 59.5 74.5 86.5 16.4 16.4 20.0 29.1 36.6 42.6 11.8 16.1 23.3 29.3 34.1 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 25 30 25 30 25 30 35 40 50 60 25 30 25 30 30 35 35 45 60 60 15 15 15 15 15 20 20 20 30 30 15 15 15 20 25 25 30 40 30 40 35 40 50 60 60 70 30 40 35 40 35 45 60 60 70 80 15 15 15 20 20 20 30 30 35 40 15 15 15 20 25 25 30 30 35 45 35 45 40 45 50 60 60 70 70 80 35 45 35 45 40 45 60 60 70 80 80 90 20 20 20 20 20 20 30 30 35 40 40 45 15 15 15 20 25 25 30 30 35 35 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 160 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078-150 Standard Motor - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 13.5 88.0 21.1 1.5 6.2 5.5 0.0 230 13.5 88.0 21.1 1.5 6.2 5.5 0.0 460 6.0 44.0 9.3 0.8 3.1 2.2 0.0 575 4.9 34.0 7.7 0.6 2.4 1.8 0.0 208 13.1 83.1 20.5 1.5 6.2 5.5 0.0 230 13.1 83.1 20.5 1.5 6.2 5.5 0.0 460 6.1 41.0 9.5 0.8 3.1 2.2 0.0 575 4.4 33.0 6.8 0.6 2.4 1.8 0.0 208 14.5 98.0 22.6 1.5 8.2 5.5 0.0 230 14.5 98.0 22.6 1.5 8.2 5.5 0.0 460 6.3 55.0 9.9 0.8 4.1 2.2 0.0 575 6.0 41.0 9.4 0.6 3.6 1.8 0.0 078 (6.5) 090 (7.5) 102 (8.5) Johnson Controls Unitary Products Electric Heat Option Model kW Stages Amps None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 39.6 39.6 54.6 70.2 96.2 39.6 39.6 61.9 79.9 110.0 18.2 18.2 30.9 40.0 55.0 14.6 14.6 24.7 31.9 43.9 38.7 38.7 54.6 70.2 96.2 38.7 38.7 61.9 79.9 110.0 18.4 18.4 30.9 40.0 55.0 13.5 13.8 24.7 31.9 43.9 43.8 43.8 57.1 72.7 98.7 43.8 43.8 64.4 82.4 112.5 19.9 19.9 32.2 41.2 56.2 18.3 18.3 26.2 33.4 45.4 45.1 45.1 61.5 77.1 103.1 45.1 45.1 68.8 86.8 116.9 20.4 20.4 33.7 42.7 57.7 16.4 16.4 26.9 34.1 46.1 44.2 44.2 61.5 77.1 103.1 44.2 44.2 68.8 86.8 116.9 20.6 20.6 33.7 42.7 57.7 15.3 16.1 26.9 34.1 46.1 49.3 49.3 64.0 79.6 105.6 49.3 49.3 71.3 89.3 119.4 22.1 22.1 34.9 44.0 59.0 20.1 20.1 28.4 35.6 47.6 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 50 50 50 50 60 70 80 80 100 110 50 50 50 50 70 70 80 90 110 125 20 25 20 25 35 35 40 45 60 60 15 20 15 20 25 30 35 35 45 50 50 50 50 50 60 70 80 80 100 110 50 50 50 50 70 70 80 90 110 125 20 25 20 25 35 35 40 45 60 60 15 20 15 20 25 30 35 35 45 50 50 60 50 60 60 70 80 80 100 110 50 60 50 60 70 80 90 90 125 125 25 25 25 25 35 35 45 45 60 60 20 25 20 25 30 30 35 40 50 50 161 528150-YTG-T-0514 ZR078-150 Standard Motor - Without Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 1.5 8.2 5.5 0.0 230 16.0 110.0 24.9 1.5 8.2 5.5 0.0 460 7.8 52.0 12.1 0.8 4.1 2.2 0.0 575 5.7 38.9 8.9 0.6 3.6 1.8 0.0 208 22.4 149.0 35.0 1.5 10.9 5.5 0.0 230 22.4 149.0 35.0 1.5 10.9 5.5 0.0 460 10.6 75.0 16.5 0.8 5.3 2.2 0.0 575 7.7 54.0 12.0 0.6 4.1 1.8 0.0 120 (10) 150 (12.5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 47.2 57.1 72.7 98.7 151.1 47.2 64.4 82.4 112.5 140.2 23.3 32.2 41.2 56.2 70.1 17.6 26.2 33.4 45.4 56.5 67.3 67.3 76.1 102.1 154.5 67.3 67.8 85.8 115.9 143.5 32.4 33.7 42.7 57.7 71.6 23.8 26.8 34.0 46.0 57.1 52.7 64.0 79.6 105.6 158.0 52.7 71.3 89.3 119.4 147.0 25.5 34.9 44.0 59.0 72.8 19.4 28.4 35.6 47.6 58.7 72.8 72.8 83.0 109.0 161.4 72.8 74.6 92.7 122.7 150.4 34.6 36.4 45.5 60.5 74.3 25.6 29.0 36.2 48.3 59.3 1 Model kW Stages Amps None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 60 60 60 70 80 80 100 110 175 175 60 60 70 80 90 90 125 125 150 175 30 30 35 35 45 45 60 60 80 80 20 25 30 30 35 40 50 50 70 70 80 90 80 90 80 90 110 110 175 175 80 90 80 90 90 100 125 125 175 175 40 45 40 45 45 50 60 70 80 80 30 30 30 30 35 40 50 50 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 162 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 0.0 230 8.7 68 13.5 1.5 6.0 5.5 0.0 460 4.6 34 7.1 0.8 3.0 2.2 0.0 575 3.5 28 5.5 0.6 2.4 1.8 0.0 208 11.9 88 18.5 1.5 6.0 5.5 0.0 230 11.9 88 18.5 1.5 6.0 5.5 0.0 460 5.2 44 8.1 0.8 3.0 2.2 0.0 575 4.8 36 7.5 0.6 2.4 1.8 0.0 208 14.1 88 22.0 1.5 4.3 5.5 0.0 230 14.1 88 22.0 1.5 4.3 5.5 0.0 460 7.7 55 12.0 0.8 2.1 2.2 0.0 575 5.1 36 7.5 0.6 2.0 1.8 0.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 18.4 18.4 23.1 31.1 46.7 18.4 18.4 25.5 34.6 52.6 9.6 9.6 12.8 17.3 26.3 7.4 13.8 21.0 23.9 23.9 31.1 46.7 59.5 23.9 25.5 34.6 52.6 67.6 11.1 12.8 17.3 26.3 33.8 9.6 13.8 21.0 27.1 27.4 27.4 32.1 47.7 60.5 71.0 27.4 27.4 35.6 53.6 68.6 80.7 14.6 14.6 17.8 26.8 34.3 40.3 10.3 14.2 21.4 27.4 32.2 23.9 23.9 30.0 38.0 53.6 23.9 23.9 32.4 41.4 59.5 11.8 11.8 15.5 20.0 29.1 9.2 16.1 23.3 29.4 30.0 38.0 53.6 66.4 29.4 32.4 41.4 59.5 74.5 13.3 15.5 20.0 29.1 36.6 11.4 16.1 23.3 29.3 32.9 32.9 39.0 54.6 67.4 77.8 32.9 33.4 42.4 60.5 75.5 87.5 16.8 16.8 20.5 29.6 37.1 43.1 12.1 16.5 23.7 29.7 34.5 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 25 25 25 35 50 25 25 30 35 60 15 15 15 20 30 15 15 25 30 30 35 50 60 30 35 35 60 70 15 15 20 30 35 15 15 25 30 35 35 40 50 70 80 35 35 40 60 70 90 20 20 20 30 35 45 15 15 25 30 35 30 30 30 40 60 30 30 35 45 60 15 15 20 20 30 15 20 25 40 40 40 60 70 40 40 45 60 80 15 20 20 30 40 15 20 25 30 45 45 45 60 70 80 45 45 45 70 80 90 20 20 25 30 40 45 15 20 25 30 35 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 163 528150-YTG-T-0514 ZR078-150 Hi Static Motor - Without Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 13.5 88.0 21.1 1.5 8.2 5.5 0.0 230 13.5 88.0 21.1 1.5 8.2 5.5 0.0 460 6.0 44.0 9.3 0.8 4.1 2.2 0.0 575 4.9 34.0 7.7 0.6 3.6 1.8 0.0 208 13.1 83.1 20.5 1.5 10.9 5.5 0.0 230 13.1 83.1 20.5 1.5 10.9 5.5 0.0 460 6.1 41.0 9.5 0.8 5.3 2.2 0.0 575 4.4 33.0 6.8 0.6 4.1 1.8 0.0 208 14.5 98.0 22.6 1.5 10.9 5.5 0.0 230 14.5 98.0 22.6 1.5 10.9 5.5 0.0 460 6.3 55.0 9.9 0.8 5.3 2.2 0.0 575 6.0 41.0 9.4 0.6 4.1 1.8 0.0 078 (6.5) 090 (7.5) 102 (8.5) 164 Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 41.6 41.6 57.1 72.7 98.7 41.6 41.6 64.4 82.4 112.5 19.2 19.2 32.2 41.2 56.2 15.8 15.8 26.2 33.4 45.4 43.4 43.4 60.5 76.1 102.1 43.4 43.4 67.8 85.8 115.9 20.6 20.6 33.7 42.7 57.7 15.2 16.0 26.8 34.0 46.0 46.5 46.5 60.5 76.1 102.1 46.5 46.5 67.8 85.8 115.9 21.1 21.1 33.7 42.7 57.7 18.8 18.8 26.8 34.0 46.0 47.1 47.1 64.0 79.6 105.6 47.1 47.1 71.3 89.3 119.4 21.4 21.4 34.9 44.0 59.0 17.6 17.6 28.4 35.6 47.6 48.9 48.9 67.3 83.0 109.0 48.9 48.9 74.6 92.7 122.7 22.8 22.9 36.4 45.5 60.5 17.0 18.2 29.0 36.2 48.3 52.0 52.0 67.3 83.0 109.0 52.0 52.0 74.6 92.7 122.7 23.3 23.3 36.4 45.5 60.5 20.6 20.6 29.0 36.2 48.3 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 50 60 50 60 60 70 80 80 100 110 50 60 50 60 70 80 90 90 125 125 25 25 25 25 35 35 45 45 60 60 20 20 20 20 30 30 35 40 50 50 50 60 50 60 70 70 80 90 110 110 50 60 50 60 70 80 90 100 125 125 25 25 25 25 35 40 45 50 60 70 20 20 20 20 30 30 35 40 50 50 60 60 60 60 70 70 80 90 110 110 60 60 60 60 70 80 90 100 125 125 25 25 25 25 35 40 45 50 60 70 20 25 20 25 30 30 35 40 50 50 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 1.5 10.9 5.5 0.0 230 16.0 110.0 24.9 1.5 10.9 5.5 0.0 460 7.8 52.0 12.1 0.8 5.3 2.2 0.0 575 5.7 38.9 8.9 0.6 4.1 1.8 0.0 208 22.4 149.0 35.0 1.5 16.1 5.5 0.0 230 22.4 149.0 35.0 1.5 16.1 5.5 0.0 460 10.6 75.0 16.5 0.8 8.1 2.2 0.0 575 7.7 54.0 12.0 0.6 6.0 1.8 0.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 MCA (Amps) MCA1 w/Pwr Exh (Amps) 49.9 60.5 76.1 102.1 154.5 49.9 67.8 85.8 115.9 143.5 24.5 33.7 42.7 57.7 71.6 18.1 26.8 34.0 46.0 57.1 72.5 72.5 82.6 108.6 161.0 72.5 74.3 92.3 122.4 150.0 35.2 37.2 46.2 61.2 75.1 25.7 29.2 36.4 48.4 59.5 55.4 67.3 83.0 109.0 161.4 55.4 74.6 92.7 122.7 150.4 26.7 36.4 45.5 60.5 74.3 19.9 29.0 36.2 48.3 59.3 78.0 78.0 89.5 115.5 167.9 78.0 81.1 99.2 129.2 156.9 37.4 39.9 49.0 64.0 77.8 27.5 31.4 38.6 50.6 61.7 1 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 60 70 70 70 80 90 110 110 175 175 60 70 70 80 90 100 125 125 175 175 30 30 35 40 45 50 60 70 80 80 20 25 30 30 35 40 50 50 70 70 90 100 90 100 90 100 110 125 175 175 90 100 90 100 100 100 125 150 175 175 45 45 45 45 50 50 70 70 90 90 30 35 30 35 40 40 50 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 165 528150-YTG-T-0514 ZR037-061 Standard Indoor Blower - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 10.0 230 8.7 68 13.5 1.5 6.0 5.5 10.0 460 4.6 34 7.1 0.8 3.0 2.2 5.0 575 3.5 28 5.5 0.6 2.4 1.8 4.0 208 11.9 88 18.5 1.5 6.0 5.5 10.0 230 11.9 88 18.5 1.5 6.0 5.5 10.0 460 5.2 44 8.1 0.8 3.0 2.2 5.0 575 4.8 36 7.5 0.6 2.4 1.8 4.0 208 14.1 88 22.0 1.5 4.3 5.5 10.0 230 14.1 88 22.0 1.5 4.3 5.5 10.0 460 7.7 55 12.0 0.8 2.1 2.2 5.0 575 5.1 36 7.5 0.6 2.0 1.8 4.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 28.7 28.7 35.6 43.6 59.2 28.7 29.0 38.0 47.1 65.1 14.7 14.7 19.0 23.5 32.6 11.5 18.8 26.0 33.9 35.6 43.6 59.2 72.0 33.9 38.0 47.1 65.1 80.1 16.1 19.0 23.5 32.6 40.1 13.6 18.8 26.0 32.1 36.6 36.6 43.6 59.2 72.0 82.5 36.6 38.0 47.1 65.1 80.1 92.2 19.2 19.2 23.5 32.6 40.1 46.1 14.0 18.8 26.0 32.1 36.9 34.2 34.9 42.5 50.5 66.1 34.2 35.9 44.9 53.9 72.0 16.9 17.3 21.8 26.3 35.3 13.3 21.1 28.3 39.4 42.5 50.5 66.1 78.9 39.4 44.9 53.9 72.0 87.0 18.3 21.8 26.3 35.3 42.8 15.4 21.1 28.3 34.3 42.1 42.5 50.5 66.1 78.9 89.3 42.1 44.9 53.9 72.0 87.0 99.0 21.4 21.8 26.3 35.3 42.8 48.8 15.8 21.1 28.3 34.3 39.1 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 40 35 40 40 45 45 60 60 70 35 40 35 40 40 45 50 60 70 80 15 20 15 20 20 25 25 30 35 40 15 15 20 25 30 30 45 50 45 50 45 60 60 70 80 80 45 50 45 50 50 60 70 80 90 90 20 20 20 25 25 30 35 40 45 45 15 20 20 25 30 30 35 35 50 50 50 50 50 60 60 70 80 80 90 90 50 50 50 50 50 60 70 80 90 90 100 100 25 25 25 25 25 30 35 40 45 45 50 50 15 20 20 25 30 30 35 35 40 40 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 166 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078-150 Standard Motor - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 13.5 88.0 21.1 1.5 6.2 5.5 10.0 230 13.5 88.0 21.1 1.5 6.2 5.5 10.0 460 6.0 44.0 9.3 0.8 3.1 2.2 5.0 575 4.9 34.0 7.7 0.6 2.4 1.8 4.0 208 13.1 83.1 20.5 1.5 6.2 5.5 10.0 230 13.1 83.1 20.5 1.5 6.2 5.5 10.0 460 6.1 41.0 9.5 0.8 3.1 2.2 5.0 575 4.4 33.0 6.8 0.6 2.4 1.8 4.0 208 14.5 98.0 22.6 1.5 8.2 5.5 10.0 230 14.5 98.0 22.6 1.5 8.2 5.5 10.0 460 6.3 55.0 9.9 0.8 4.1 2.2 5.0 575 6.0 41.0 9.4 0.6 3.6 1.8 4.0 078 (6.5) 090 (7.5) 102 (8.5) Johnson Controls Unitary Products Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 49.6 49.6 67.1 82.7 108.7 49.6 49.6 74.4 92.4 122.5 23.2 23.7 37.2 46.2 61.2 18.6 18.8 29.7 36.9 48.9 48.7 48.7 67.1 82.7 108.7 48.7 48.7 74.4 92.4 122.5 23.4 23.7 37.2 46.2 61.2 17.5 18.8 29.7 36.9 48.9 53.8 53.8 69.6 85.2 111.2 53.8 53.8 76.9 94.9 125.0 24.9 24.9 38.4 47.5 62.5 22.3 22.3 31.2 38.4 50.4 55.1 55.1 74.0 89.6 115.6 55.1 55.1 81.3 99.3 129.4 25.4 26.4 39.9 49.0 64.0 20.4 21.1 31.9 39.1 51.1 54.2 54.2 74.0 89.6 115.6 54.2 54.2 81.3 99.3 129.4 25.6 26.4 39.9 49.0 64.0 19.3 21.1 31.9 39.1 51.1 59.3 59.3 76.5 92.1 118.1 59.3 59.3 83.8 101.8 131.9 27.1 27.7 41.2 50.2 65.2 24.1 24.1 33.4 40.6 52.6 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 60 60 60 60 70 80 90 90 110 125 60 60 60 60 80 90 100 100 125 150 25 30 25 30 40 40 50 50 70 70 20 25 20 25 30 35 40 40 50 60 60 60 60 60 70 80 90 90 110 125 60 60 60 60 80 90 100 100 125 150 25 30 25 30 40 40 50 50 70 70 20 20 20 25 30 35 40 40 50 60 60 70 60 70 70 80 90 100 125 125 60 70 60 70 80 90 100 110 125 150 30 30 30 30 40 45 50 60 70 70 25 30 25 30 35 35 40 45 60 60 167 528150-YTG-T-0514 ZR078-150 Standard Motor - With Powered Convenience Outlet (Continued) Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 1.5 8.2 5.5 10.0 230 16.0 110.0 24.9 1.5 8.2 5.5 10.0 460 7.8 52.0 12.1 0.8 4.1 2.2 5.0 575 5.7 38.9 8.9 0.6 3.6 1.8 4.0 208 22.4 149.0 35.0 1.5 10.9 5.5 10.0 230 22.4 149.0 35.0 1.5 10.9 5.5 10.0 460 10.6 75.0 16.5 0.8 5.3 2.2 5.0 575 7.7 54.0 12.0 0.6 4.1 1.8 4.0 120 (10) 150 (12.5) Electric Heat Option Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 57.2 69.6 85.2 111.2 163.6 57.2 76.9 94.9 125.0 152.7 28.3 38.4 47.5 62.5 76.3 21.6 31.2 38.4 50.4 61.5 77.3 77.3 88.6 114.6 167.0 77.3 80.3 98.3 128.4 156.0 37.4 39.9 49.0 64.0 77.8 27.8 31.8 39.0 51.0 62.1 62.7 76.5 92.1 118.1 170.5 62.7 83.8 101.8 131.9 159.5 30.5 41.2 50.2 65.2 79.1 23.4 33.4 40.6 52.6 63.7 82.8 82.8 95.5 121.5 173.9 82.8 87.1 105.2 135.2 162.9 39.6 42.7 51.7 66.7 80.6 29.6 34.0 41.2 53.3 64.3 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 70 70 70 80 90 100 125 125 175 175 70 70 80 90 100 110 125 150 175 175 35 35 40 45 50 60 70 70 90 90 25 25 35 35 40 45 60 60 70 70 90 100 90 100 90 100 125 125 175 175 90 100 90 100 100 110 150 150 175 175 45 50 45 50 50 60 70 70 90 90 35 35 35 35 40 45 60 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. 168 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR037-061 Hi Static Indoor Blower - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 8.7 68 13.5 1.5 6.0 5.5 10.0 230 8.7 68 13.5 1.5 6.0 5.5 10.0 460 4.6 34 7.1 0.8 3.0 2.2 5.0 575 3.5 28 5.5 0.6 2.4 1.8 4.0 208 11.9 88 18.5 1.5 6.0 5.5 10.0 230 11.9 88 18.5 1.5 6.0 5.5 10.0 460 5.2 44 8.1 0.8 3.0 2.2 5.0 575 4.8 36 7.5 0.6 2.4 1.8 4.0 208 14.1 88 22.0 1.5 4.3 5.5 10.0 230 14.1 88 22.0 1.5 4.3 5.5 10.0 460 7.7 55 12.0 0.8 2.1 2.2 5.0 575 5.1 36 7.5 0.6 2.0 1.8 4.0 037 (3) 049 (4) 061 (5) Electric Heat Option MCA (Amps) MCA1 w/Pwr Exh (Amps) 28.7 28.7 35.6 43.6 59.2 28.7 29.0 38.0 47.1 65.1 14.7 14.7 19.0 23.5 32.6 11.5 18.8 26.0 33.9 35.6 43.6 59.2 72.0 33.9 38.0 47.1 65.1 80.1 16.1 19.0 23.5 32.6 40.1 13.6 18.8 26.0 32.1 37.4 37.4 44.6 60.2 73.0 83.5 37.4 39.0 48.1 66.1 81.1 93.2 19.6 19.6 24.0 33.1 40.6 46.6 14.3 19.2 26.4 32.4 37.2 34.2 34.9 42.5 50.5 66.1 34.2 35.9 44.9 53.9 72.0 16.9 17.3 21.8 26.3 35.3 13.3 21.1 28.3 39.4 42.5 50.5 66.1 78.9 39.4 44.9 53.9 72.0 87.0 18.3 21.8 26.3 35.3 42.8 15.4 21.1 28.3 34.3 42.9 43.5 51.5 67.1 79.9 90.3 42.9 45.9 54.9 73.0 88.0 100.0 21.8 22.3 26.8 35.8 43.3 49.3 16.1 21.5 28.7 34.7 39.5 1 Model kW Stages Amps None E03 E06 E08 E15 None E03 E06 E08 E15 None E03 E06 E08 E15 None E08 E15 None E06 E08 E15 E20 None E06 E08 E15 E20 None E06 E08 E15 E20 None E08 E15 E20 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E06 E08 E15 E20 E23 None E08 E15 E20 E23 2.3 4.5 6.8 11.3 3 6 9 15 3 6 9 15 9 15 4.5 6.8 11.3 15 6 9 15 20 6 9 15 20 9 15 20 4.5 6.8 11.3 15 18 6 9 15 20 24 6 9 15 20 24 9 15 20 24 1 1 1 2 1 1 1 2 1 1 1 2 1 2 1 1 2 2 1 1 2 2 1 1 2 2 1 2 2 1 1 2 2 2 1 1 2 2 2 1 1 2 2 2 1 2 2 2 6.4 12.5 18.9 31.4 7.2 14.4 21.7 36.1 3.6 7.2 10.8 18.0 8.7 14.4 12.5 18.9 31.4 41.6 14.4 21.7 36.1 48.1 7.2 10.8 18.0 24.1 8.7 14.4 19.2 12.5 18.9 31.4 41.6 50.0 14.4 21.7 36.1 48.1 57.7 7.2 10.8 18.0 24.1 28.9 8.7 14.4 19.2 23.1 2 Max Fuse2/ Max Fuse3 / Breaker3 Breaker Size w/ Size Pwr Exh (Amps) (Amps) 35 35 40 45 60 35 35 40 50 70 15 15 20 25 35 15 20 30 45 45 45 60 80 45 45 50 70 90 20 20 25 35 45 15 20 30 35 50 50 50 70 80 90 50 50 50 70 90 100 25 25 25 35 45 50 15 20 30 35 40 40 40 45 60 70 40 40 45 60 80 20 20 25 30 40 15 25 30 50 50 60 70 80 50 50 60 80 90 20 25 30 40 45 20 25 30 35 50 50 60 70 80 100 50 50 60 80 90 100 25 25 30 40 45 50 20 25 30 35 40 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Johnson Controls Unitary Products 169 528150-YTG-T-0514 ZR078-150 Hi Static Motor - With Powered Convenience Outlet Size (Tons) Volt Compressors (each) RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 13.5 88.0 21.1 1.5 8.2 5.5 10.0 230 13.5 88.0 21.1 1.5 8.2 5.5 10.0 460 6.0 44.0 9.3 0.8 4.1 2.2 5.0 575 4.9 34.0 7.7 0.6 3.6 1.8 4.0 208 13.1 83.1 20.5 1.5 10.9 5.5 10.0 230 13.1 83.1 20.5 1.5 10.9 5.5 10.0 460 6.1 41.0 9.5 0.8 5.3 2.2 5.0 575 4.4 33.0 6.8 0.6 4.1 1.8 4.0 208 14.5 98.0 22.6 1.5 10.9 5.5 10.0 230 14.5 98.0 22.6 1.5 10.9 5.5 10.0 460 6.3 55.0 9.9 0.8 5.3 2.2 5.0 575 6.0 41.0 9.4 0.6 4.1 1.8 4.0 078 (6.5) 090 (7.5) 102 (8.5) 170 Electric Heat Option Model kW None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 None E09 E18 E24 E36 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 6.8 13.5 18.0 25.5 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 9.0 18.0 24.0 34.0 MCA1 (Amps) MCA1 w/Pwr Exh (Amps) 51.6 51.6 69.6 85.2 111.2 51.6 51.6 76.9 94.9 125.0 24.2 24.9 38.4 47.5 62.5 19.8 20.3 31.2 38.4 50.4 53.4 53.4 73.0 88.6 114.6 53.4 53.4 80.3 98.3 128.4 25.6 26.4 39.9 49.0 64.0 19.2 21.0 31.8 39.0 51.0 56.5 56.5 73.0 88.6 114.6 56.5 56.5 80.3 98.3 128.4 26.1 26.4 39.9 49.0 64.0 22.8 22.8 31.8 39.0 51.0 57.1 57.1 76.5 92.1 118.1 57.1 57.1 83.8 101.8 131.9 26.4 27.7 41.2 50.2 65.2 21.6 22.6 33.4 40.6 52.6 58.9 58.9 79.8 95.5 121.5 58.9 60.1 87.1 105.2 135.2 27.8 29.2 42.7 51.7 66.7 21.0 23.2 34.0 41.2 53.3 62.0 62.0 79.8 95.5 121.5 62.0 62.0 87.1 105.2 135.2 28.3 29.2 42.7 51.7 66.7 24.6 24.6 34.0 41.2 53.3 Stages Amps 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 1 2 2 2 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 18.9 37.5 50.0 70.8 21.7 43.3 57.7 81.8 10.8 21.7 28.9 40.9 8.7 17.3 23.1 32.7 2 Max Fuse2/ Max Fuse3 / Breaker Breaker3 Size w/ Pwr Size Exh (Amps) (Amps) 60 70 60 70 70 80 90 100 125 125 60 70 60 70 80 90 100 110 125 150 30 30 30 30 40 45 50 60 70 70 20 25 25 25 35 35 40 45 60 60 60 70 60 70 80 80 90 100 125 125 60 70 60 70 90 90 100 110 150 150 30 30 30 30 40 45 50 60 70 70 20 25 25 25 35 35 40 45 60 60 70 70 70 70 80 80 90 100 125 125 70 70 70 70 90 90 100 110 150 150 30 30 30 30 40 45 50 60 70 70 25 30 25 30 35 35 40 45 60 60 Johnson Controls Unitary Products 528150-YTG-T-0514 ZR078-150 Hi Static Motor - With Powered Convenience Outlet (Continued) Size (Tons) Compressors (each) Volt RLA LRA MCC OD Fan Motors (each) Supply Blower Motor Pwr Exh Motor Pwr Conv Outlet FLA FLA FLA FLA 208 16.0 110.0 24.9 1.5 10.9 5.5 10.0 230 16.0 110.0 24.9 1.5 10.9 5.5 10.0 460 7.8 52.0 12.1 0.8 5.3 2.2 5.0 575 5.7 38.9 8.9 0.6 4.1 1.8 4.0 208 22.4 149.0 35.0 1.5 16.1 5.5 10.0 230 22.4 149.0 35.0 1.5 16.1 5.5 10.0 460 10.6 75.0 16.5 0.8 8.1 2.2 5.0 575 7.7 54.0 12.0 0.6 6.0 1.8 4.0 120 (10) 150 (12.5) Electric Heat Option MCA1 (Amps) Model kW None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 None E18 E24 E36 E54 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 13.5 18.0 25.5 40.6 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 18.0 24.0 34.0 54.0 Stages Amps 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 37.5 50.0 70.8 112.7 43.3 57.7 81.8 129.9 21.7 28.9 40.9 65.0 17.3 23.1 32.7 52.0 59.9 73.0 88.6 114.6 167.0 59.9 80.3 98.3 128.4 156.0 29.5 39.9 49.0 64.0 77.8 22.1 31.8 39.0 51.0 62.1 82.5 82.5 95.1 121.1 173.5 82.5 86.8 104.8 134.9 162.5 40.2 43.4 52.5 67.5 81.3 29.7 34.2 41.4 53.4 64.5 MCA1 w/Pwr Exh (Amps) 65.4 79.8 95.5 121.5 173.9 65.4 87.1 105.2 135.2 162.9 31.7 42.7 51.7 66.7 80.6 23.9 34.0 41.2 53.3 64.3 88.0 88.0 102.0 128.0 180.4 88.0 93.6 111.7 141.7 169.4 42.4 46.2 55.2 70.2 84.1 31.5 36.4 43.6 55.6 66.7 2 Max Fuse2/ Max Fuse3 / Breaker 3 Breaker Size w/ Pwr Size Exh (Amps) (Amps) 70 80 80 80 90 100 125 125 175 175 70 80 90 90 100 110 150 150 175 175 35 35 40 45 50 60 70 70 90 90 25 25 35 35 40 45 60 60 70 70 100 110 100 110 100 110 125 150 175 200 100 110 100 110 110 125 150 150 175 175 50 50 50 50 60 60 70 80 90 90 35 35 35 40 45 45 60 60 70 70 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. Electric Heat Multipliers Voltage Nominal 240 480 600 Applied 208 230 460 575 kW Capacity Multipliers1 0.75 0.92 0.92 0.92 1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters applied at lower voltages. Johnson Controls Unitary Products 171 528150-YTG-T-0514 Typical Wiring Diagrams ZH/ZJ037-150 Typical Wiring Diagrams Typical ZH/ZJ037-061 Cooling Unit with Gas Heat 230 Volt Wiring Diagram 172 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZR037-061 Reheat Unit with Gas Heat 230 Volt Wiring Diagram Johnson Controls Unitary Products 173 528150-YTG-T-0514 Typical ZH/ZJ037-061 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram 174 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZR037-061 Reheat Unit with Gas Heat 460/575 Volt Wiring Diagram Johnson Controls Unitary Products 175 528150-YTG-T-0514 Typical ZH/ZJ037-061 Cooling Unit with/without Electric Heat Wiring Diagram 176 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZR037-061 Reheat Unit with/without Electric Heat Wiring Diagram Johnson Controls Unitary Products 177 528150-YTG-T-0514 Typical ZH/ZJ/ZR078-120 Cooling Unit with Gas Heat 230 Volt Wiring Diagram 178 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZH/ZJ/ZR078-120 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram Johnson Controls Unitary Products 179 528150-YTG-T-0514 Typical ZH/ZJ/ZR078-120 Cooling Unit with/without Electric Heat Wiring Diagram 180 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZH/ZJ/ZR150 Cooling Unit with Gas Heat 230 Volt Wiring Diagram Johnson Controls Unitary Products 181 528150-YTG-T-0514 Typical ZH/ZJ/ZR150 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram 182 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZH/ZJ/ZR150 Cooling Unit with/without Electric Heat Wiring Diagram Johnson Controls Unitary Products 183 528150-YTG-T-0514 Typical ZR037-061 Reheat Wiring Diagram 184 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZR078-120 Reheat Wiring Diagram Johnson Controls Unitary Products 185 528150-YTG-T-0514 Typical ZR150 Reheat Wiring Diagram 186 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZH/ZJ078-150 Factory Installed VFD (Option) Johnson Controls Unitary Products 187 528150-YTG-T-0514 Typical ZH/ZJ078-150 Factory Installed VFD with Manual Bypass (Option) 188 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZH/ZJ078-150 BAS Ready Unit with Factory Installed VFD (Option) Johnson Controls Unitary Products 189 528150-YTG-T-0514 Typical ZH/ZJ078-150 BAS Ready Unit with Factory Installed VFD and Manual Bypass (Option) 190 Johnson Controls Unitary Products 528150-YTG-T-0514 Typical ZH/ZJ078-150 VFD Ready Unit (Option) Johnson Controls Unitary Products 191 528150-YTG-T-0514 Weights and Dimensions ZH/ZJ037-150 Unit Weights Unit 4 Point Load Weight Unit 6 Point Load Weight FRONT FRONT LEFT LEFT B C B A A E F D Y X FRONT LEFT Weight (lbs.) Center of Gravity Size Model (Tons) Shipping Operating X Y 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 037 (3) 049 (4) 061 (5) 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) 192 D C 4 Point Load Location (lbs.) A B C D A 6 Point Load Location (lbs.) B C D E F ZH 728 723 40 26 175 143 182 223 121 105 92 117 134 154 ZH 768 763 40 26 185 151 192 235 128 111 97 124 141 162 ZH 869 864 40 26 210 171 217 266 145 126 110 140 160 184 ZH 915 910 38 24 212 158 230 309 149 121 100 147 177 217 ZH 915 910 38 24 212 158 230 309 149 121 100 147 177 217 ZH 1052 1047 38 24 244 182 265 356 171 139 116 169 203 249 ZH 1095 1090 38 24 254 189 276 371 178 145 120 176 211 260 ZH 1285 1280 48 24 240 281 410 350 156 173 192 280 252 227 ZJ 745 740 40 26 180 147 186 228 124 108 95 120 137 157 ZJ 780 775 40 24 174 142 207 253 120 104 91 133 152 175 ZJ 775 770 40 24 172 141 205 251 119 103 91 132 151 174 ZJ 1035 1030 39 25 245 191 260 333 170 144 122 167 195 232 ZJ 1055 1050 39 25 250 195 265 340 174 146 125 170 199 236 ZJ 1065 1060 38 24 247 184 268 360 173 141 117 171 206 253 ZJ 1075 1070 39 24 245 191 278 357 170 143 122 178 209 248 ZJ 1285 1280 48 24 240 281 410 350 156 173 192 280 252 227 Johnson Controls Unitary Products 528150-YTG-T-0514 Weights and Dimensions ZR037-150 Unit Weights Unit 4 Point Load Weight Unit 6 Point Load Weight FRONT FRONT LEFT LEFT B C B A A D C E F D Y X FRONT LEFT Weight (lbs.) Center of Gravity Size Model (Tons) Shipping Operating X Y 4 Point Load Location (lbs.) A B C D A 6 Point Load Location (lbs.) B C D E F 037 (3) ZR 872 867 40.3 25.5 205 170 223 269 141 124 110 144 163 185 049 (4) ZR 885 880 40.9 25.1 202 172 232 273 139 124 112 151 168 187 061 (5) ZR 872 867 41 25 198 169 230 269 136 122 110 150 166 184 ZR 962 957 38 23 214 159 249 335 150 122 101 159 191 234 ZR 970 965 38 23 216 161 251 337 151 123 102 160 193 236 ZR 1205 1200 38 25.5 297 221 291 390 208 170 141 185 223 274 ZR 1205 1200 38 25.5 297 221 291 390 208 170 141 185 223 274 ZR 1470 1465 51 25.5 270 363 477 355 172 207 254 334 272 226 078 (6.5) 090 (7.5) 102 (8.5) 120 (10) 150 (12.5) Johnson Controls Unitary Products 193 528150-YTG-T-0514 ZH/ZJ/ZR037-150 Unit Accessory Weights Unit Accessory Economizer Power Exhaust Electric Heat1 Gas Heat2 Variable Frequency Drive3 Weight (lbs.) Shipping Operating 90 85 40 35 49 49 110 110 30 30 1. Weight given is for the maximum heater size available (54KW). 2. Weight given is for the maximum number of tube heat exchangers available (8 tube). 3. Weight includes mounting hardware, controls and manual bypass option (6-1/2 to 12-1/2 ton only). ZH/ZJ/ZR037-150 Unit Dimensions ZH/ZJ037-049 and ZR037 29.75 15.51 29.52 59.00 Ø 25.31 B See detail A for gas inlet A C D E 11 3/8 F See detail B for drain location LEFT 4 3/16 FRONT 59 21 3/16 27 5/16 89 194 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH/ZJ 061, ZR049 - 061 and ZH/ZJ/ZR078 thru 120 29.69 15.25 15.38 59.00 15.38 2X Ø 24.38 B SEE DETAIL A FOR GAS INLET A C D E 11.38 F 59.00 4.19 LEFT 27.31 SEE DETAIL B FOR DRAIN LOCATION 21.19 89.00 FRONT Johnson Controls Unitary Products 195 528150-YTG-T-0514 ZH/ZJ/ZR150 28.86 29.66 44.09 15.23 14.85 29.03 29.03 14.85 Ø 24.58 TYP. 4 PL. 15.23 B See detail A for gas inlet A C D E 11 3/8 F See detail B for drain location LEFT 4 3/16 59 21 3/16 FRONT 27 5/16 89 ZH/ZJ/ZR037-150 Unit Physical Dimensions Unit Model Number ZH037, 049, 061, 078, 090 ZH102, 120 ZH150 ZJ037, 049, 061 ZJ078, 090, 102, 120 ZJ150 ZR037, 049, 061 ZR078, 090 ZR102, 120 ZR150 196 A 42 50 3/4 50 3/4 42 50 3/4 50 3/4 42 42 50 3/4 50 3/4 B 89 89 119 1/2 89 89 119 1/2 89 89 89 119 1/2 Dimension (in.) C 22 1/8 18 30 3/16 24 30 3/16 24 22 1/8 18 30 3/16 24 30 3/16 24 22 1/8 18 22 1/8 18 30 3/16 24 30 3/16 24 D 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 15 17 17 15 17 17 15 15 17 17 E 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 6 6 6 6 6 6 6 6 6 6 F 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 Johnson Controls Unitary Products 528150-YTG-T-0514 Detail A 3.184 3.184 Gas Pipe Inlet Gas Pipe Inlet Ø 2.000 Ø 2.000 Gas Exhaust Vent Gas Exhaust Vent Ø 3.126 Ø 3.126 17.541 14.594 7.715 7.705 4.737 4.727 42” CABINET 50 3/4” CABINET Detail B ZH/ZJ/ZR037-150 Unit Clearances Direction Top1 Front Rear 5-3/8 Distance (in.) 72 36 36 Direction Right Left Bottom2 Distance (in.) 12 36 0 1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet. 2. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. 3/4” FPT Johnson Controls Unitary Products 197 528150-YTG-T-0514 ZH/ZJ/ZR037-150 Unit Bottom Duct Openings TOP VIEW 89 32 11/16 6 13/16 6 13/16 SUPPLY AIR RETURN AIR 27 1/2 LEFT 18 24 RIGHT 21 20 1/8 19 1/8 17 1/8 12 5/16 Bottom condensate drain 14 1/2 25 9/16 Bottom gas supply entry 16 3/8 18 1/16 FRONT Bottom power, control and convenience outlet wiring entry 3X Ø 0.875 Ø 2.469 198 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH/ZJ/ZR037-150 Unit Electrical Entry Disconnect Swith Cover Power Entry Ø 2-1/2 Control Entry Ø 7/8 Power Entry Ø 2-1/2 Convenience Outlet Cover Convenience Outlet Power Entry Ø 7/8 FRONT ZH/ZJ/ZR037-120 Unit Side Duct Openings Dot Plugs 18-1/4 Return Air A Supply Air D B 2-31/32 5-5/32 C 31-11/16 Johnson Controls Unitary Products 199 528150-YTG-T-0514 ZH/ZJ/ZR150 Unit Side Duct Openings Dot Plugs 18-1/4 A D B 5-5/32 2-7/8 C 31-5/8 ZH/ZJ/ZR037-150 Side Duct Dimensions Unit Model Number ZH037, 049, 061, 078, 090 ZH102, 120 ZH150 ZJ037, 049, 061 ZJ078, 090, 102, 120 ZJ150 ZR037, 049, 061 ZR078, 090 ZR102, 120 ZR150 200 A 27 3/4 28 1/4 28 1/4 27 3/4 28 1/4 28 1/4 27 3/4 27 3/4 28 1/4 28 1/4 12 18 18 12 18 18 12 12 18 18 Dimension (in.) B C 1/16 27 1/2 1/16 28 1/4 1/16 28 1/4 1/16 27 1/2 1/16 28 1/4 1/16 28 1/4 1/16 27 1/2 1/16 27 1/2 1/16 28 1/4 1/16 28 1/4 D 16 18 1/4 18 1/4 16 18 1/4 18 1/4 16 16 18 1/4 18 1/4 Johnson Controls Unitary Products 528150-YTG-T-0514 ZH/ZJ/ZR037-150 Unit Left Duct Opening 30-3/8 4-5/16 ZH/ZJ/ZR037-150 Unit Accessory Dimensions ZH/ZJ/ZR037-150 Roof Curb RIGHT 80-5/8 INSULATED DECK UNDER CONDENSER SECTION 20 SUPPLY 20 6 RETURN 2 TYP. 30 INSULATED DECK UNDER COMPRESSOR SECTION 50-1/2 8 or 14 Johnson Controls Unitary Products FRONT 201 528150-YTG-T-0514 ZH/ZJ/ZR037-150 Transition Roof Curb 2 TYP 50-1/2 23 4 30-1/2 80-5/8 26 RETURN SUPPLY 10 76-5/8 59-1/4 94 FRONT RIGHT 64-1/4 ZH/ZJ/ZR037-150 Economizer Assembly 58 1/4 88 1/4 24 3/4 Tall Units 26 1/8 Short Units 32 1/16 39 1/2 OR 47 1/2 Fresh Air Hood For Economizer Outside Air Intake Hood 35 3/4 Relief Hood For Power Exhaust Or Barometric Relief 26 202 25 3/4 23 3/4 31 7/8 Johnson Controls Unitary Products 528150-YTG-T-0514 Economizer Options Economizer Usage Application Cabinet Height Description Model Side Return All Horizontal economizer without barometric relief 2EE047060241 42" Slab Economizer, 42” tall cabinet 2EE047075242 50" Slab Economizer, 50” tall cabinet 2EE047083242 ERV or End Return 1. Barometric relief must be ordered separately and installed in duct work. 2. Barometric relief or fresh air hood not included. Must be ordered separately. Field Installed Horizontal Economizer W/Power Exhaust Return Air Damper Field Installed Duct Work Fresh Air Damper Power Exhaust Barometric Relief Damper Barometric Relief Hood Fresh Air Hood Slab Economizer Downflow W/Power Exhaust Fresh Air Hood Low Leak Slab Economizer Power Exhaust Barometric Relief Damper Johnson Controls Unitary Products Barometric Relief Hood 203 Slab Economizer End Return W/Power Exhaust Fresh Air Hood Field Installed Duct Work Slab Low Leak Economizer Power Exhaust Barometric Relief Damper Barometric Relief Hood Subject to change without notice. Printed in U.S.A. Copyright © 2014 by Johnson Controls, Inc. All rights reserved. York International Corporation 5005 York Drive Norman, OK 73069 528150-YTG-T-0514 Supersedes: 528150-YTG-S-0414
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : clarchd Create Date : 2004:07:21 16:14:32Z Modify Date : 2014:06:17 13:33:43-05:00 Language : en Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.150055, 2012/11/19-18:45:32 Creator Tool : FrameMaker 12.0.2 Metadata Date : 2014:06:17 13:33:43-05:00 Producer : Acrobat Distiller 11.0 (Windows) Format : application/pdf Title : 528150-YTG-T-0514.fm Creator : clarchd Document ID : uuid:55708b7e-24e2-417e-a54c-971852da54a9 Instance ID : uuid:0b3bbc5c-d1a1-4fa8-876c-cc9be163b4f4 Page Mode : UseOutlines Page Count : 204EXIF Metadata provided by EXIF.tools