York Zh Predator R410A 11 7 Eer Technical Guide 528150 YTG T 0514

2015-09-09

: York Zh-Predator-R410A-11-7-Eer-Technical-Guide york-zh-predator-r410a-11-7-eer-technical-guide-812284 york pdf

Open the PDF directly: View PDF PDF.
Page Count: 204

DownloadYork Zh-Predator-R410A-11-7-Eer-Technical-Guide 528150-YTG-T-0514  York-zh-predator-r410a-11-7-eer-technical-guide
Open PDF In BrowserView PDF
528150-YTG-T-0514

®

TECHNICAL GUIDE
R-410A
ZH/ZJ/ZR SERIES
3 - 12-1/2 TON
60 Hertz

Description
ASHRAE 90.1 COMPLIANT
YORK® Predator® units are convertible single packages with a
common footprint cabinet and common roof curb for all 3
through 12-1/2 ton models. All 6-1/2 through 12-1/2 ton units
have two compressors with independent refrigeration circuits to
provide 2 stages of cooling. The units were designed for light
commercial applications and can be easily installed on a roof
curb, slab, or frame.
All Predator® units are self-contained and assembled on rigid
full perimeter base rails allowing for 3-way forklift access and
overhead rigging. Every unit is completely charged, wired,
piped, and tested at the factory to provide a quick and easy field
installation.
All units are convertible between side and down airflow.
Independent economizer designs are used on side and down
discharge applications, as well as all tonnage sizes.
Predator® units are available in the following configurations:
cooling only, cooling with electric heat, cooling with gas heat,
reheat only, reheat with electric heat and reheat with gas heat.
Electric heaters are available as factory-installed options or
field-installed accessories.

ZH/ZJ/ZR 3 THROUGH 10 TON
All units provide constant supply air volume. A variable air
volume (VAV) option, featuring a variable frequency drive, is
available on 6-1/2 through 12-1/2 ton ZH/ZJ models only.
Tested in accordance with:

ZH/ZJ/ZR 12-1/2 TON

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

528150-YTG-T-0514

Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Economizer Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204

Component Location
Cooling With Gas Heat (3 Through 5 Ton)

“Simplicity®” Control board w/
screw connectors for T-stat
wiring and Network
Connections

Disconnect location
(optional disconnect switch)

Filter drier (solid core)
Filter access 3-5 Ton Reheat
(2" or 4”
Micro-Channel Aluminum
filter options)
Tube/Aluminum Fin
Condenser
(Single Orifice System shown.
See Actual Model Physical Data for details)

Slide out motor and
blower assembly for
easy adjustment
and service
Filter drier (solid core)
3-5 Ton Cooling

Second model nameplate
inside hinged access
panel

Belt-drive blower
motor

Base rails w/
forklift slots
(three sides)
and lifting
holes
Roof curbs in eight-and
fourteen-inch heights.
Roof curbs for transitioning
from York Sunline™ footprint
to the ZH/ZJ/ZR Series footprint
are available
(field-installed accessory)
Compressor access (highefficiency compressor)

Power ventor
motor
20-gauge aluminized
steel tubular heat
exchanger for long life
(stainless steel option)
Side entry power
and control wiring
knockouts
Toolless door
latch

2

Slide-out drain pan
with ¾" NPT
connection

One or Two stage gas heating to
maintain warm, comfortable
temperature
Intelligent control board
for safe and efficient
operation

Johnson Controls Unitary Products

528150-YTG-T-0514
Cooling With Gas Heat (6 1/2 Through 10 Tons)

Simplicity® control board
Disconnect location
w/screw connector for T-stat
wiring and network connections (optional disconnect switch)

Filter access
(2” or 4” filter options)

Filter drier
(solid core)
Micro-Channel Aluminum
Tube/Aluminum Fin
Condenser

Terminal block for
hi-voltage connection
Second model
nameplate
inside hinged
access panel

Slide-out motor and
blower assembly for
easy adjustment
and service
Belt-drive
blower motor

Dual stage
cooling for
maximum
comfort

VFD location (optional)
Power ventor motor

Compressor #2
access (highefficiency
compressor)

20-gauge aluminized steel tubular
heat exchanger for
long life (stainless
steel option)

Base rails w/forklift
slots (three sides)
and lifting holes
Roof curbs in eight- and
fourteen-inch heights. Roof
curbs for transitioning from
York Sunline™ footprint to
the ZH/ZJ/ZR Series footprints
are also available (field
installed accessory)

Johnson Controls Unitary Products

Slide-out drain pan
with 3/4” NPT,
female connection

Toolless
door latch

Side entry power
and control wiring
knockouts

Two-stage gas
heating to maintain
warm, comfortable
temperature
Intelligent control
board for safe and
efficient operation

Compressor #1 access
(high-efficiency compressor)

3

528150-YTG-T-0514

Nomenclature
3-12.5 Ton York® Model Number Nomenclature
Z H 090 N10 A 2 A AA 6 0 1 2 4 A
Product Category

Product Style
A = Style A
B = Style B
C = Style C

Z = A/C, Single Pkg., R-410A

Product Identifier
H = 11.7-11.8 EER
J = 12.2 EER
R = Reheat

Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS

Nominal Cooling Capacity
037 = 3 Ton
049 = 4 Ton
061 = 5 Ton
078 = 6.5 Ton
090 = 7.5 Ton
102 = 8.5 Ton
120 = 10.0 Ton
150 = 12.5 Ton

Johnson Controller UNT 1126 (N2 protocol), DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort II Controller
Simplicity IntelliComfort II Controller w/Simplicity®LINC
York Commercial Comfort System (YCCS) Rtu Controller
Hot Gas Bypass (Standard on VAV, Optional on CV)
IntelliSpeed with VFD

Heat Type and Nominal Heat Capacity
(Unit Size Allowed)
C00 = Cooling Only. No heat installed
Single Stage Natural Gas Heat Options
A05 = 49 MBH Output Aluminized Steel,
Single Stage (037, 049)
A07 = 65 MBH Output Aluminized Steel,
Single Stage (037, 049, 061)
A09 = 97 MBH Output Aluminized Steel,
Single Stage (037, 049, 061)
A13 = 129 MBH Output Aluminized Steel,
Single Stage (061)
B05 = 49 MBH Output Stainless Sleel,
Single Stage (037, 049)
B07 = 65 MBH Output Stainless Steel,
Single Stage (037, 049, 061)
B09 = 97 MBH Output Stainless Steel,
Single Stage (037, 049, 061)
B13 = 129 MBH Output Stainless Steel,
Single Stage (061)

IntelliSpeed, VFD and Manual Bypass
IntelliSpeed, VFD Ready (for customer-provided, field-installed drive)
Variable Air Volume, VFD (not available with factory installed BAS options)
Variable Air Volume, VFD with Simplicity®LINC (not available with factory installed BAS options)
Variable Air Volume, VFD and Manual Bypass
(not available with factory installed BAS options)
Variable Air Volume, VFD and Manual Bypass with Simplicity®LINC
(not available with factory installed BAS options)
Variable Air Volume, VFD (BAS ready)
Variable Air Volume, VFD and Manual Bypass (BAS ready)
Variable Air Volume, VFD Ready (for customer-provided, field-installed drive)
Variable Air Volume, VFD Ready with Simplicity®LINC
(for customer-provided, field-installed drive)
2" Pleated Filters, MERV 7
4" Pleated Filters, MERV 13
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)
Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

Two Stage Natural Gas Heat Options
N05 = 49 MBH Output Aluminized Steel,
Two Stage (037, 049)
N07 = 65 MBH Output Aluminized Steel,
Two Stage (037, 049, 061)
N09 = 97 MBH Output Aluminized Steel,
Two Stage (037, 049, 061)
N13 = 129 MBH Output Aluminized Steel,
Two Stage (061)
S05 = 49 MBH Output Stainless Sleel,
Two Stage (037, 049)
S07 = 65 MBH Output Stainless Steel,
Two Stage (037, 049, 061)
S09 = 97 MBH Output Stainless Steel,
Two Stage (037, 049, 061)
S13 = 129 MBH Output Stainless Steel,
Two Stage (061)
N10 = 100 MBH Output Aluminized Steel,
Two Stage (078, 090, 102)
N15 = 150 MBH Output Aluminized Steel,
Two Stage (078, 090, 102, 120, 150)
N20 = 200 MBH Output Aluminized Steel,
Two Stage (120, 150)
S10 = 100 MBH Output Stainless Steel,
Two Stage (078, 090, 102)
S15 = 150 MBH Output Stainless Steel,
Two Stage (078, 090, 102, 120, 150)
S20 = 200 MBH Output Stainless Steel,
Two Stage (120, 150)
Electric Heat Options
E03 = 3 KW (037)
E06 = 6 KW (037, 049, 061)
E08 = 9 KW (037, 049, 061)
E09 = 9 KW (078, 090, 102)
E15 = 15 KW (037, 049, 061)
E18 = 18 KW (078, 090, 102, 120, 150)
E20 = 20 KW (049, 061)
E23 = 24 KW (061)
E24 = 24 KW (078, 090, 102, 120, 150)
E36 = 36 KW (078, 090, 102, 120, 150)
E54 = 54 KW (120, 150)

Product Generation
6 = Sixth Generation
Additional Options
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch

AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
RC = Coil Guard, Shipping Bag & American Flag
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
EA = ElectroFin Condenser Coil
EJ = ElectroFin Evaporator Coil
ES = ElectroFin Cond & Evap Coils

ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Installation Options

Voltage
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
Airflow
A = Std. Motor
D = Std. Motor/Motorized Damper (Downflow Only)
H = Std Motor/Low Leak Econ/Barometric Relief
(Downflow, Slab Economizer Only)
J = Std Motor/Low Leak Econ/Power Exhaust (Downflow,
Slab Economizer Only)
E = Std Motor/Horizontal Economizer (No Baro)
N = Hi Static
R = Hi Static/Motorized Damper (Downflow Only)
V = Hi Static Mtr/Low Leak Econ/Barometric Relief
(Downflow, Slab Economizer Only)
W = Hi Static Mtr/Low Leak Econ/Power Exhaust
(Downflow, Slab Economizer Only)
S = Hi Static Mtr/Horizontal Economizer (No Baro)

A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet

4

Johnson Controls Unitary Products

528150-YTG-T-0514

Features and Benefits
Standard Features
• High Efficiency – High efficiency units reach as high as
12.2 EER. Gas/electric units have electronic spark ignition
and power vented combustion with steady state efficiencies
of 80%. These efficiencies exceed all legislated minimum
levels and provide low operating costs.
• Service Friendly – The Predator® incorporates a number
of enhancements which improve serviceability.
The motor and blower slide out of the unit as a common
assembly. This facilitates greater access to all the indoor
airflow components, thus simplifying maintenance and
adjustment.
Service time is reduced through the use of hinged,
toolless panels. Such panels provide access to frequently
inspected components and areas, including the control
box, compressors, filters, indoor motor & blower, and the
heating section. The panels are screwed in place at the
factory to prevent access by children or other
unauthorized persons. It is recommended that the panels
be secured with screws once service is complete.
Service windows have been placed in both condenser
section walls. Rotation of the cover allows easy access to
the condenser coils for cleaning or inspection.
Both the unit control board and ignition control board utilize
flash codes to aid in diagnosis of unit malfunctions. Unique
alarm codes quickly identify the source of the unit alarm.
All units use four filters of the same standard size. This
standardization simplifies selections for filter replacement.
The non-corrosive drain pan slides out of the unit to permit
easy cleaning. The drain pan is accessed by removing the
drain pan cover plate on the rear of the unit. Once the plate is
removed, the drain pan slides out through the rear of the unit.
All Predator® units have a second model nameplate
located inside the control access door. This is to prevent
deterioration of the nameplate through weathering.
• Coil Technology – All ZH/ZJ condensers utilize MicroChannel “all-aluminum” condensers which provide
improved heat transfer capabilities and reduced charge
volumes. All evaporators utilize a conventional copper
tube/aluminum fin design for proven reliability and
performance. ZR037 thru 061 models utilize MicroChannel condenser coils, ZR078 thru 150 models utilize
copper tube/aluminum fin condenser coils.
• Environmentally Aware – For improved Indoor Air
Quality, a combination of foil faced and elastometric
rubber insulation is used exclusively throughout the units.
• Balanced Heating – The Predator® two stage gas heating
offers “Ultimate Heating Comfort” with a balance between
1st and 2nd stage gas heating. The first stage of a gas heat
Predator® unit provides 70% or 75% of the heating capacity
3 thru 5 tons and 60% heating capacity 6-1/2 thru 12-1/2
tons. Balanced heating allows the unit to better maintain
desired temperatures.
• Convertible Airflow Design – The side duct openings
are covered when they leave the factory. If a side supply/

Johnson Controls Unitary Products

•

return is desired, the installer simply removes the two side
duct covers from the outside of the unit and installs them
over the down shot openings. No panel cutting is required.
Convertible airflow design allows maximum field flexibility
and minimum inventory.
• System Protection - Suction line freezestats are supplied
on all units to protect against loss of charge and coil frosting
when the economizer operates at low outdoor air
temperatures while the compressors are running. Every unit
has solid-core liquid line filter-driers and high and lowpressure switches. Internal compressor protection is
standard on all compressors. Scroll compressors do not
require crankcase heaters. Phase Monitors are standard on
units with scroll compressors. This accessory monitors the
incoming power to the unit and protects the unit from phase
loss and reversed phase rotation.
Advanced Controls - Simplicity® control boards have
standardized a number of features previously available
only as options or by utilizing additional controls.
•

Low Ambient - An integrated low-ambient control
allows all units to operate in the cooling mode down to
0F outdoor ambient without additional assistance.
Optionally, the control board can be programmed to
lockout the compressors when the outdoor air temperature is low or when free cooling is available.

The Simplicity® control board used in this product
will effectively operate the cooling system down to
0°F when this product is applied in a comfort cooling
application for people. An economizer is typically
included in this type of application. When applying
this product for process cooling applications (computer rooms, switchgear, etc.), please reference
applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1-877UPG-SERV for guidance. Additional accessories
may be needed for stable operation at temperatures
below 30° F.
•

Anti-Short Cycle Protection - To aid compressor life,
an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured
by programmable minimum run times. For testing, the
anti-short cycle delay can be temporarily overridden
with the push of a button.

•

Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan
delay times are independent of one another. All units
are programmed with default values based upon their
configuration of cooling and heat.

•

Safety Monitoring - The control board monitors the
high and low-pressure switches, the freezestats, the
gas valve, if applicable, and the temperature limit
switch on gas and electric heat units. The unit control

5

528150-YTG-T-0514
board will alarm on ignition failures, compressor lockouts and repeated limit switch trips.
•

•

Nuisance Trip Protection and Strikes - To prevent
nuisance trouble calls, the control board uses a “three
times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times
within two hours before the unit control board will lock
out the associated compressor.
On Board Diagnostics - Each alarm will energize a
trouble light on the thermostat, if so equipped, and
flash an alarm code on the control board LED. Each
high and low-pressure switch alarm as well as each
freezestat alarm has its own flash code. The control
board saves the five most recent alarms in memory,
and these alarms can be reviewed at any time.
Alarms and programmed values are retained through
the loss of power.

• Reliable – From the beginning – All units undergo
computer automated testing before they leave the factory.
Units are tested for refrigerant charge and pressure, unit
amperage, and 100% functionality. For the long term – All
Predator® units are painted with a long lasting, powder
paint that stands up over the life of the unit. The paint
used has been proven by a 1000 hour salt spray test.
• Flexible Placement – All models and configurations
share the same cabinet/footprint and thus the same roof
curb. You have the flexibility to set one curb and choose
the correct tonnage size and heating option after the
internal loads have been determined.
To further simplify planning and installation, Predator®
cabinets are designed to fit your roof. With the optional
roof curb, the unit ductwork is designed to fit around 24”
on-center joists or between 48” on-center joists.
The drain pan can be rotated to drain to either the front or
the rear of the unit. Additionally, the drain pan can be
fitted to drain through the roof curb. As it is sometimes
difficult to have a level installation, the drain pan features
a generous slope to ensure proper drainage.
• Full Perimeter Base Rails – The permanently attached
base rails provide a solid foundation for the entire unit and
protect the unit during shipment. The rails offer forklift
access from 3 sides, and rigging holes are available so that
an overhead crane can be used to place the units on a roof.
• Easy Installation – Gas and electric utility knockouts are
supplied in the unit underside as well as the side of the unit.
A clearly identified location is provided to mount a field
supplied electrical disconnect switch. Utility connections can
be made quickly and with a minimum amount of field labor.
All units are shipped with 2” throw-away filters installed.
• Wide Range of Indoor Airflows – All indoor fan motors
are belt-drive type providing maximum flexibility to handle
most airflow requirements. For high static applications,
factory installed alternate indoor fan motors are available.
With the optional indoor fan motor, all units can supply
nominal airflow at a minimum of 1.5” ESP.

6

A variable air volume (VAV) option using a variable
frequency drive is available on 6-1/2 through 12-1/2 ton
models for applications requiring a constant supply duct
pressure. A differential pressure transducer is used to
monitor supply duct static pressure while a VAV control
board provides a speed reference signal to the VFD to
control the output of the indoor blower motor.
• Warranty - All models include a 1-year limited warranty
on the complete unit. Compressors and electric heater
elements each carry a 5-year warranty. Aluminized steel
and stainless steel tubular heat exchangers carry a 10year warranty.

Factory Installed Options
YORK® offers several equipment options factory installed, for
the Predator®line.
• Optional Factory Installed Economizers - Predator units
offer a variety of optional factory installed economizers
with low leak dampers. The outdoor air enthalpy sensor
enables economizer operation if the outdoor enthalpy is
less than the setpoint of the economizer logic module. See
economizer options section to determine the correct
economizer for your application.
• Downflow Slab Economizers (with barometric relief
and fresh air hood) - All units offer a variety of optional
factory installed down flow economizers that are
shipped, installed and wired with low leak dampers
designed to meet ASHRAE 90.1-2010, AMCA 511
Class 1A damper, and the International Energy
Conservation Code (IECC) certification requirements by
achieving leakage rates of 3 cfm/sq. ft. at 1" of static
pressure. Each economizer goes through a rigorous
60,000 cycle test. Dry bulb, single enthalpy, and dual
enthalpy (with field installed kit) can be selected. The
economizer has spring return, fully modulating damper
actuators and is capable of introducing up to 100%
outdoor air. As the outdoor air intake dampers open, the
return air dampers close. The changeover from
mechanical refrigeration to economizer operation is
regulated by the outdoor air dry bulb temperature or the
outdoor air enthalpy input. The dual enthalpy kit
provides a second input used to monitor the return air
(field installed). The installer needs only to assemble the
outdoor air hood, attach the enthalpy control the hood
and mount the hood to the unit (Hood and control are
provided). When selected with BAS Ready
Economizer Option the actuator requires 2-10 VDC
input from an external source, such as a field-installed
or factory-installed BAS controller. BAS-ready actuators
have an adjustable auxiliary end-switch for optional
power exhaust control.
• Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except
economizer is not designed with low leak dampers and
you must order the duct mount barometric relief
separately. You must order a 1EH0408 if you are
installing a power exhaust. You can order a 1RD0411

Johnson Controls Unitary Products

528150-YTG-T-0514
Barometric Relief for horizontal flow economizers
only.

•
•

•

•

• For units with optional VAV or Simplicity® Intelli-Comfort
II™ control, a factory-installed, dry bulb sensor
determines if outdoor air temperature is low enough to
provide free-cooling operation. (Field-installed humidity
sensors for either outdoor air or outdoor & return air
streams are available for single enthalpy and differential
enthalpy configurations, respectively).
• VAV or Simplicity® INTELLI-Comfort II™ control, a
factory-installed dry bulb sensor determines if outdoor
air temperature is low enough to provide free-cooling
operation. (Field-installed humidity sensors for either
outdoor air or outdoor & return air streams are available
for single enthalpy and differential enthalpy
configurations, respectively.)
Power Exhaust (Downflow only) - This accessory
installs in the unit with a down flow economizer.
Motorized Outdoor Air Damper - The motorized outdoor
air damper includes a slide-in/plug-in damper assembly
with an outdoor air hood and filters. The outdoor air
dampers open to the preset position when the indoor fan
motor is energized. The damper has a range of 0% to
100% outdoor air entry. Factory installed option or field
installed accessory.
Alternate Indoor Blower Motor - For applications with
high static restrictions, units are offered with optional
indoor motors that provide higher static output and/or
higher airflow, depending upon the installer’s needs.
Variable Air Volume (VAV; 6-1/2 through 12-1/2 ton,
only - A factory-installed variable frequency drive (VFD),
mounted in the Blower Access compartment, is used to
control the speed of the indoor blower motor in order to
maintain a constant static pressure in the supply duct. A
pressure transducer and VAV control board are mounted
inside the control box. The drive comes completely wired
and pre-programmed from the factory.
An optional, factory-installed manual bypass switch
available with factory-installed VFD can be found in the
Blower Motor Access compartment. The switch can be
used to either route power to the VFD for modulating
control of the blower motor, to bypass the drive and
operate the motor at full speed, or to power the drive (and
not the motor) for diagnostic purposes.
Due to space limitations, VAV is not available with any of
the factory-installed BAS options, but is available with
'BAS-ready' models. Terminal blocks are provided in the
control box for field wiring of the customer-installed BAS.
A 'VFD-ready' option provides the provisions for a
customer-installed drive. The unit comes with a mounting
bracket installed in the Blower Access compartment which
may accommodate other vendor's drives depending on
their size. In order to utilize the unit's mounting bracket,
the maximum recommended drive dimensions are limited
to approximately 9" H x 5" W x 7.5" D.
If the drive will not fit in the allotted space, then it will have
to be mounted elsewhere; either within the building on a
perpendicular wall which is not subjected to excessive
temperature, vibration, humidity, dust, corrosive gas,

Johnson Controls Unitary Products

explosive gas, etc., or within an appropriate enclosure
rated for outside installation to safeguard against
moisture, dust and excessive heat. A terminal block
located in the control box is provided for field connection
of the VFD controls.
• IntelliSpeed™ Supply Fan Control Option (ASHRAE
90.1 compliant, section 6.4.3.10) - Units configured with
the IntelliSpeed™ Supply Fan Option will contain a VFD
for variable volume supply fan operation. This option
allows the supply fan RPM to vary based on the number
of compressors or heating stages energized. The
economizer's minimum position will also be configurable
to vary based on the supply fan VFD frequency output.
• Aluminized Steel Gas Heat Exchanger - For
applications in non-corrosive environments.
• Stainless Steel Gas Heat Exchanger - For applications
in corrosive environments, this option provides a full
stainless steel heat exchanger assembly.
• Stainless Steel Drain Pan - An optional rust-proof
stainless steel drain pan is available to provide years of
trouble-free operation in corrosive environments.
• Electric Heaters - The electric heaters range from 3kW to
54kW and are available in all the voltage options of the
base units. All heaters are intended for single point power
supply.
• Disconnect Switch - For gas heat units and cooling units
with electric heat, a HACR breaker sized to the unit is
provided. For cooling only units, a switch sized to the
largest electric heat available for the particular unit is
provided. Factory installed option only.
• Convenience Outlet - (Non-Powered/Powered) - This
option locates a 120V single-phase GFCI outlet with cover,
on the corner of the unit housing adjacent to the
compressors. The “Non-powered” option requires the
installer to provide the 120V single-phase power source and
wiring. The “Powered” option is powered by a stepdown
transformer in the unit. Factory installed option only.
• Smoke Detectors - The smoke detectors stop operation
of the unit by interrupting power to the control board if
smoke is detected within the air compartment. Available
for both the supply and/or return air configurations.
• Filters - 2” Pleated MERV 7 or 4” Pleated MERV 13 are
available to meet LEED requirements. A 2” Throwaway is
shipped as standard.

Factory-installed smoke detectors may be subjected to
extreme temperatures during "off" times due to outside air
infiltration. These smoke detectors have an operational
limit of -4°F to 158°F. Smoke detectors installed in areas
that could be outside this range will have to be relocated to
prevent false alarms.
• Phase Monitors - Designed to prevent unit damage. The
phase monitor will shut the unit down in an out-of phase
condition. (Standard on units with Scroll Compressors.)

7

528150-YTG-T-0514
• Coil Guard - Customers can purchase a coil guard kit to
protect the condenser coil from damage. Additionally, this
kit stops animals and foreign objects from entering the
space between the inner condenser coil and the main
cabinet. This is not a hail guard kit.
• Dirty Filter Switch - This kit includes a differential
pressure switch that energizes the fault light on the unit
thermostat, indicating that there is an abnormally high
pressure drop across the filters. Factory installed option or
field installed accessory.
• Technicoat Condenser Coils - The condenser coils are
coated with a phenolic coating for protection against
corrosion due to harsh environments.
• Technicoat Evaporator Coil - The evaporator coils are
coated with a phenolic coating for protection against
corrosion due to harsh environments.
• ElectroFin® E-coat Condenser Coils - The condenser
coils are coated with an epoxy polymer coating to protect
against corrosion.
• ElectroFin® E-coat Evaporator Coils - The evaporator
coils are coated with an epoxy polymer coating to protect
against corrosion.
• Hot Gas Bypass - Allows operation during low load
conditions while avoiding coil frosting and damage to
compressor. When suction pressure falls below valve
setpoint, the valve modulates hot gas to the inlet of the
evaporator. HGBP is standard on all units with VAV and
optional with constant-volume units.

Control Options
• Simplicity® INTELLI-Comfort II™ Control communicates
on a MODBUS RTU protocol network - The York®
Simplicity® INTELLI-Comfort II™ control is factory installed.
It includes a supply air sensor, a return air sensor, and an
outside air sensor. There are provisions for a field installed
dirty filter indicator switch, an air-proving switch, an Outside
Air Humidity sensor, a Return Air Humidity sensor, an
Inside IAQ sensor, and an Outside Air IAQ sensor.
Construction mode operation, 365-day real time clock with
7 day programming plus holiday scheduling is built-in. Two
different modes of demand ventilation are achieved through
the INTELLI-Comfort II™ using CO2 sensors. It uses an
inside CO2 sensor to perform Demand Ventilation. It can
also use an Outside CO2 sensor to perform Differential
Demand Ventilation. It uses a Patented Comfort Ventilation
algorithm to provide comfortable ventilation air
temperature. The patented economizer-loading algorithm
will protect the equipment when harsh operating conditions
exist. Humidity in the occupied space or return duct can be
monitored and controlled via humidity sensors and the onboard connection for hot gas re-heat system. It uses the
INTELLI-Start™ algorithm to maximize energy savings by
recovering the building from the Unoccupied Setpoints to
the Occupied Setpoints just in time for the Occupied Time
Period to begin. The Simplicity® INTELLI-Comfort II™
balances space temperature, ventilation air temperature,
CO2 and humidity for ultimate comfort.
• Simplicity® INTELLI-Comfort II™ with Simplicity®LINC
Control - The York® Simplicity® INTELLI-Comfort II™
with Simplicity®LINC control is factory installed. It
8

•

•

•

•

•

includes all the features of the INTELLI-Comfort II™
control with an additional control to translate
communications from MODBUS to the BACnet MSTP
protocol.
Novar® BAS Control - The Novar® building automation
system controller is factory installed. Includes supply air
sensor, return air sensor, dirty filter indicator switch, and
air proving switch.
Johnson Controls BAS Control - The Johnson Control
YK-UNT-1126 building automation system controller is
factory installed. Includes supply air sensor, return air
sensor, dirty filter indicator switch, and air proving switch.
CPC BAS Control - The Computer Process Controls
Model 810-3060 ARTC Advanced Rooftop building
automation system controller is factory installed. Includes
supply air sensor, return air sensor, dirty filter indicator
switch and air proving switch.
Honeywell BAS Control - The Honeywell W7750C
building automation system controller is factory installed.
Includes air supply sensor, return air sensor, dirty filter
indicator switch, and air proving switch.
York Commercial Comfort System (YCCS) - Provides
rooftop system integration for YCCS single zone and
change-over bypass systems.

Field Installed Accessories
YORK® offers several equipment accessories for field
installation, for the Predator® line.
• Downflow Slab Economizers (with fresh air hood and
without barometric relief) - All units offer a variety of
optional factory installed down flow economizers that are
shipped, installed and wired with low leak dampers designed
to meet ASHRAE 90.1-2010, AMCA 511 Class 1A damper,
and the International Energy Conservation Code (IECC)
certification requirements by achieving leakage rates of 3
cfm/sq. ft. at 1" of static pressure. Each economizer goes
through a rigorous 60,000 cycle test. Dry bulb, single
enthalpy, and dual enthalpy (with field installed kit) can be
selected. The economizer has spring return, fully modulating
damper actuators and is capable of introducing up to 100%
outdoor air. As the outdoor air intake dampers open, the
return air dampers close. The changeover from mechanical
refrigeration to economizer operation is regulated by the
outdoor air dry bulb temperature or the outdoor air enthalpy
input. The dual enthalpy kit provides a second input used to
monitor the return air (field installed). The installer needs only
to assemble the outdoor air hood, attach the enthalpy control
the hood and mount the hood to the unit (Hood and control
are provided).
• Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except
economizer is not designed with low leak dampers and
you must order the duct mount barometric relief
separately. You must order a 1EH0408 if you are
installing a power exhaust. You can order a 1RD0411
Barometric Relief for horizontal flow economizers
only.
• Dual Enthalpy Control, Accessory - This kit contains
the required components to convert a single enthalpy
economizer to dual enthalpy.
Johnson Controls Unitary Products

528150-YTG-T-0514
• Barometric Relief Damper - Zero to 100% capacity
barometric relief dampers for use with horizontal flow, or
field installed slab economizers.
• Power Exhaust - This accessory installs in the unit with a
down flow economizer. Power exhaust plugs into the
connector in the unit bulkhead. You must purchase
1EH0408 barometric relief when applying to a
horizontal flow application.
• Manual Outdoor Air Damper - Like the motorized outdoor
air damper, each manual outdoor air damper includes a
slide-in damper assembly with an outdoor air hood and
filters. Customers have a choice of dampers with ranges of
0% to 100% or 0% to 35% outdoor air entry.
• Motorized Outdoor Air Damper - The motorized outdoor
air damper includes a slide-in/plug-in damper assembly with
an outdoor air hood and filters. The outdoor air dampers
open to the preset position when the indoor fan motor is
energized. The damper has a range of 0% to 100% outdoor
air entry. Factory installed option or field installed accessory.
• Smoke Detectors - The smoke detectors stop operation
of the unit by interrupting power to the control board if
smoke is detected within the air compartment.
• CO2 Sensor - Senses CO2 levels and automatically
overrides the economizer when levels rise above the
preset limits.
• Dirty Filter Switch - This kit includes a differential
pressure switch that energizes the fault light on the unit
thermostat, indicating that there is an abnormally high
pressure drop across the filters.
• Coil Guard - Field installed decorative wire coil guard.
• Hail Guard - This kit includes a sloped hood which installs
over the outside condenser coil and prevents damage to
the coil fins from hail strikes. Field installed accessory only.
• Flue Exhaust Extension Kit - In locations with wind or
weather conditions which may interfere with proper
exhausting of furnace combustion products, this kit can be
installed to prevent the flue exhaust from entering nearby
fresh air intakes.
• -60°F Gas Heat Kit - For installations which require gas
heat units to perform in low ambient temperatures, a gas
section heating kit is available. This kit provides electric
heat in the gas heat controls section to ensure the gas
valve and controls will continue to function properly at
extremely low temperatures.

Johnson Controls Unitary Products

• Gas Heat High Altitude Kit - This kit converts a gas heat
unit to operate at high altitudes, 2,000 to 6,000 feet.
Conversion kits are available for natural gas and propane.
• Gas Heat Propane Conversion Kit - This kit converts a
gas-fired heater from natural gas to propane. It contains the
main burner orifices and gas valve replacement springs.
• Gas Piping Kit - Contains pipe nipples, fittings and gas cock
required for gas supply connection with external shut off.
• Electric Heaters - The electric heaters range from 3kW to
54kW and are available in all the voltage options of the
base units. The 54kW/208-240 volt, field-installed heater
kit is not available with VAV units due to a lack of space to
accommodate the heater’s fuse block accessory.
All heaters are dual staged. Cooling units include an
adapter panel for easy installation of the electric heaters.
Necessary hardware and connectors are included with the
heaters. All heaters are intended for single point power
supply.
• Low Limit / Compressor Lockout Kit
• Compressor Lockout (CLO): To prevent mechanical
(compressorized) operation of the unit during cold
outdoor conditions where there is a risk of returning
liquid refrigerant back to the compressors.
• Low Limit Control (LLC): To prevent the supply air
from dropping below a specified setpoint by utilizing the
units first stage heating means when there is a demand
for cooling during cold outside conditions.
• Metal Frame Filter Kit - Metal frame with polyester filter
medium.
• Permanent Filters - Permanent filters are available.
• Roof Curbs - The roof curbs have insulated decks and are
shipped disassembled The roof curbs are available in 8” and
14” heights. For applications with security concerns, burglar
bars are available for the duct openings of the roof curbs.
• Roof Curb Transition - Single Piece Adapter (10” High) Roof curbs for transitioning from Sunline™ units to
Predator® units. Fits 7.5 to 12.5 Sunline™ roof curbs only.
• Burglar Bars - Mount in the supply and return openings
to prevent entry into the duct work.
• Thermostat - The units are designed to operate with 24volt electronic and electro-mechanical thermostats. All 6.5
thru 12.5 ton ZH,ZJ units and all 3 thru 12.5 ton ZR units
(with or without an economizer) operate with two-stage
heat/two-stage cool or two-stage cooling only
thermostats, depending upon unit configuration.

9

528150-YTG-T-0514

Accessories
Field Installed Accessories - Non-Electrical
MODEL
1BD0408

VOLTAGE DESCRIPTION
All
Burglar Bars, Downflow

1CG0419
1CG0420
1CG0427
1CG0428

All
All
All
All

Coil Guard
Coil Guard
Coil Guard
Coil Guard

1HG0411
1HG0415
1FE0412
1FF0414
1FF0415
1FL0402
1FL0423
1GP0405
1HA0442
1HA0450
1HA0451
1HA0443
1HA0452
1HA0453
1NP0442
1NP0454
1NP0455
1RC0470
1RC0471

All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All

1RC0472

All

1WC0412
1LN0407
1LN0408

All
All
All

Hail Guard Kit
Hail Guard Kit
Flue Exhaust Extension Kit
2" only Metal Filter Frame Kit
2" only Metal Filter Frame Kit
Permanent 2" only Filter Kit Includes (4) Four Filters)
Permanent 2" only Filter Kit (Includes (4) four Filters)
Gas Piping Kit
High Altitude Kit for Natural Gas
High Altitude Kit for Natural Gas
High Altitude Kit for Natural Gas
High Altitude Kit for Propane
High Altitude Kit for Propane
High Altitude Kit for Propane
Propane Conversion Kit
Propane Conversion Kit
Propane Conversion Kit
Roof Curb, 8" Height
Roof Curb, 14" Height
Roof Curb, Transition (7.5 T thru 12.5T Sunline to Predator 312T)
Wooden Crate for extra protection during shipping and
handling
Low NOx Kit
Low NOx Kit

10

WHERE USED
All Cabinets
(Electric / Electric Models), 50” Tall Standard
Cabinets
(Gas / Electric Models), 50" Tall Standard Cabinets
(Electric / Electric Models), 42” Tall Cabinets
(Gas / Electric Models), 42" Tall Cabinets
All Tall (50") Standard Cabinets, (Excludes 12.5T
"V" cabinets)
All Short (42") Standard Cabinets
All Cabinets
All Tall 50" Cabinets
All Tall 42" Cabinets
All Tall 50" Cabinets
All Tall 42" Cabinets
All Cabinets
All 6 - 12T Cabinets
3 - 5T (80, 120 & 160 MBH Input)
3 - 4T (60 MBH Input)
All 6 - 12T Cabinets
3 - 5T (80, 120 & 160 MBH Input)
3 - 4T (60 MBH Input)
All 6 - 12T Cabinets
3 - 5T (80, 120 & 160 MBH Input)
3 - 4T (60 MBH Input)
All Cabinets
All Cabinets
All Cabinets
Standard Cabinets Only (not applicable to units
119" in length)
3 - 5T (80, 120 & 160 MBH Input)
3 - 5T (60 MBH Input)

Johnson Controls Unitary Products

528150-YTG-T-0514

Accessories (Continued)
Field Installed Accessories - Electric Heat
MODEL
2TP04520925
2TP04520946
2TP04520958
2TP04531825
2TP04531846
2TP04521858
2TP04532425
2TP04532446
2TP04522458
2TP04533625
2TP04533646
2TP04523658
2TP04525425
2TP04525446
2TP04525458
2TP04540925
2TP04540946
2TP04540958
2TP04541825
2TP04541846
2TP04541858
2TP04542425
2TP04542446
2TP04542458
2TP04543625
2TP04543646
2TP04543658
2TP04510325
2TP04510346
2TP04510625
2TP04510646
2TP04510825
2TP04510846
2TP04510858
2TP04511525
2TP04511546
2TP04511558
2TP04512025
2TP04512046
2TP04512058
2TP04512325
2TP04512346
2TP04512358

VOLTAGE
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
230
460
230
460
230
460
575
230
460
575
230
460
575
230
460
575

DESCRIPTION

WHERE USED

9kW Electric Heat

All 50" Cabinet 6.5 and 8.5 Ton Models

18kW Electric Heat

All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models

24kW Electric Heat

All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models

36kW Electric Heat

All 50" Cabinet 6.5, 8.5, 10 and 12.5 Ton Models

54kW Electric Heat

All 50" 10 and 12.5 Ton Models

9kW Electric Heat

All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models

18kW Electric Heat

All 42" 6.5, 7.5 and 8.5 Ton Models

24kW Electric Heat

All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models

36kW Electric Heat

All 42" Cabinet 6.5, 7.5 and 8.5 Ton Models

3kW Electric Heat

All 42" Cabinet 3 Ton Models

6kW Electric Heat

All 42" Cabinet 3, 4 and 5 Ton Models

9kW Electric Heat

All 42" Cabinet 3, 4 and 5 Ton Models

15kW Electric Heat

All 42" Cabinet 3, 4 and 5 Ton Models

20kW Electric Heat

All 42" 4 and 5 Ton Models

24kW Electric Heat

All 42" Cabinet 5 Ton Models

Johnson Controls Unitary Products

11

528150-YTG-T-0514

Accessories (Continued)
Field Installed Accessories - Fresh Air
MODEL
1EH0408
1FA0413
1FA0414
1RD0411
2EC04700924

VOLTAGE
All
All
All
All
All

2EE04708324

All

DESCRIPTION
Barometric Relief Kit for Power Exhaust, Horizontal Application
Manual Outside Air Damper 0-35%, Downflow
Manual Outside Air Damper 0-100%, Downflow
Barometric Relief Kit for Horizontal Applications
Dual Enthalpy Control
Downflow Economizer, Slab type for ERV & Downflow
Applications, (no Barometric Relief or FA hood)

Downflow Economizer, Slab type for ERV & Downflow
Applications, (no Barometric Relief or FA hood)
All
Horizontal Economizer without Barometric Relief
2EE04706024
All
Motorized Damper, Downflow without Barometric Relief
2MD04703224
All
Motorized Damper, Horizontal
2MD04703724
230
Power Exhaust 230V Downflow or Horizontal
2PE04704706*
460
Power Exhaust 460V Downflow or Horizontal
2PE04704746*
575
Power Exhaust 575V Downflow or Horizontal
2PE04704758*
* Must be installed in return Duct on Horizontal Applications and a 1EH0408 is required.
2EE04707524

All

WHERE USED
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All 50" Cabinets
All 42" Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets

Field Installed Accessories - Controls
MODEL
2AP0401
2AQ04700324B
2AQ04700424C
2DF0402
2DH04700024
2SD04700624
2SD04700824
2SD04700924
2SD04701024

VOLTAGE
All
All
All
All
All
All
All
All
All

DESCRIPTION
Air Proving Switch
CO² Space Accessory
CO² Unit Accessory
Dirty Air Switch
Humidistat

WHERE USED
All Units
All Units
All Units
All Units
All Units
All Gen 4 or older units with 2" Filter only capable
Cabinets
All Gen 5 units with 2" & 4" Filters
All Gen 5 units with 2" & 4" Filters
All Gen 5 units with 2" & 4" Filters

Smoke Detector for Supply or Return
Smoke Detector for Supply
Smoke Detector for Return
Smoke Detector for Supply and Return

Field Installed Accessories - Electrical
MODEL
2BC04700106
2BC04700151
2BC04700154
2LA04704632

VOLTAGE
230
460
575
All

DESCRIPTION
Gas heat kit, -60ºF
Gas heat kit, -60ºF
Gas heat kit, -60ºF
Low Ambient Kit

Guide Specifications
GENERAL
Units shall be manufactured by Unitary Products in an ISO
9001 certified facility. YORK® Predator® units are convertible
single packages with a common footprint cabinet and common
roof curb for all 3 through 12-1/2 ton models. All 6-1/2 through
12-1/2 ton units have two compressors with independent R410A refrigeration circuits to provide 2 stages of cooling. The
units were designed for light commercial applications and can
be easily installed on a roof curb, slab, or frame. All Predator®
units are self-contained and assembled on rigid full perimeter
base rails allowing for 3-way forklift access and overhead
rigging. Every unit is completely charged with R-410A, wired,
piped, and tested at the factory to provide a quick and easy
field installation. All units are convertible between side and
down airflow. Independent economizer designs are used on
side and down discharge applications, as well as all tonnage
sizes. Predator® units are available in the following
configurations: cooling only, cooling with electric heat, cooling
with gas heat, reheat only, reheat with electric heat and reheat

12

WHERE USED
All Units
All Units
All Units
All 3 - 10T units (excludes 12.5T "V" cabinets)

with gas heat. Electric heaters are available as factory-installed
options or field-installed accessories.
DESCRIPTION
Units shall be factory assembled, single package, (Elec/Elec, Gas/
Elec), designed for outdoor installation. They shall have built in
field convertible duct connections for down discharge supply/return
or horizontal discharge supply/return and be available with factory
installed options or field installed accessories. The units shall be
factory wired, piped and charged with R-410A refrigerant and
factory tested prior to shipment. All unit wiring shall be both
numbered and color coded. The cooling performance shall be
rated in accordance with DOE and AHRI test procedures. Units
shall be CSA certified to ANSI Z21.47 and UL 1995/CAN/CSA No.
236-M90 standards.
UNIT CABINET
Unit cabinet shall be constructed of galvanized steel with
exterior surfaces coated with a non-chalking, powder paint
finish, certified at 1000 hour salt spray test per ASTM-B117

Johnson Controls Unitary Products

528150-YTG-T-0514
standards. Indoor blower sections shall be insulated with up to
1” thick insulation coated on the airside. Either aluminum foil
faced or elastometric rubber insulation shall be used in the
unit’s compartments and be fastened to prevent insulation from
entering the air stream. Cabinet doors shall be hinged with
toolless access for easy servicing and maintenance. Full
perimeter base rails shall be provided to assure reliable transit
of equipment, overhead rigging, fork truck access and proper
sealing on roof curb applications. Disposable 2” filters shall be
furnished as standard and be accessible through hinged access
door. Fan performance measuring ports shall be provided on
the outside of the cabinet to allow accurate air measurements
of evaporator fan performance without removing panels or
creating bypass of the coils. Condensate pan shall be slide out
design, constructed of a non corrosive material, internally
sloped and conforming to ASHRAE 62-B9 standards.
Condensate connection shall be a minimum of ¾” I.D. female
and be rigid mount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
Fan shall be a belt drive assembly and include an adjustable
pitch motor pulley. Job site selected brake horsepower shall not
exceed the motors nameplate horsepower rating plus the service factor. Units shall be designed to operate within the service
factor. Fan wheel shall be double inlet type with forward curve
blades, dynamically balanced to operate smoothly throughout
the entire range of operation. Airflow design shall be constant
volume. Bearings shall be sealed and permanently lubricated
for longer life and no maintenance. Entire blower assembly and
motor shall be slide out design.

c. Condenser coils shall have aluminum plate fins
mechanically bonded to seamless internally enhanced
copper tubes with all joints brazed or Micro-Channel
aluminum tube, aluminum fins.
d. Condenser coils shall be of the draw-thru design.
Refrigerant Circuit and Refrigerant Safety Components shall
include:
a. Independent fixed-orifice
expansion devices.

or

thermally

operated

b. Solid core filter drier/strainer to eliminate any moisture or
foreign matter.
c. Accessible service gage connections on both suction
and discharge lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing or
troubleshooting, without losing charge.
d. The 6-1/2 through 12-1/2 ton unit shall have two
independent refrigerant circuits, equally split in 50%
capacity increments.
Unit Controls:
a. Unit shall be complete with self-contained low-voltage
control circuit protected by a resettable circuit breaker on
the 24-volt transformer side.
b. Unit shall incorporate a lockout circuit which provides
reset capability at the space thermostat or base unit
should any of the following standard safety devices trip
and shut off compressor:
• Loss-of-charge/Low-pressure switch.

OUTDOOR (CONDENSER) FAN ASSEMBLY
The outdoor fans shall be of the direct drive type, discharge air
vertically, have aluminum blades riveted to corrosion resistant
steel spider brackets and shall be dynamically balanced for
smooth operation. The outdoor fan motors shall have permanently
lubricated bearings internally protected against overload
conditions and staged independently. A cleaning window shall be
provided on two sides of the units for coil cleaning.
REFRIGERANT COMPONENTS
Compressors:
a. Shall be fully hermetic type, direct drive, internally
protected with internal high-pressure relief and over
temperature protection. The hermetic motor shall be
suction gas cooled and have a voltage range of + or –
10% of the unit nameplate voltage.
b. Shall have internal spring isolation and sound muffling to
minimize vibration and noise, and be externally isolated
on a dedicated, independent mounting.
Coils:
a. Evaporator coils shall have aluminum plate fins
mechanically bonded to seamless internally enhanced
copper tubes with all joints brazed. Special Phenolic
coating shall be available as a factory option.
b. Evaporator coils shall be of the direct expansion, drawthru design.
Johnson Controls Unitary Products

• High-pressure switch.
• Freeze-protection thermostat, evaporator coil. If any of
the above safety devices trip, an LED (light-emitting
diode) indicator shall flash a diagnostic code that
indicates which safety switch has tripped.
c. Unit shall incorporate “AUTO RESET” compressor over
temperature, over current protection.
d. Unit shall operate with conventional thermostat designs
and have a low voltage terminal strip for easy hook-up.
e. Unit control board shall have on-board diagnostics and
fault code display.
f. Standard controls shall include anti-short cycle and low
voltage protection, and permit cooling operation down to
0 ºF.
g. Control board shall monitor each refrigerant safety switch
independently.
h. Control board shall retain last 5 fault codes in nonvolatile memory, which will not be lost in the event of a
power loss.
GAS HEATING SECTION (IF EQUIPPED)
Heat exchanger and exhaust system shall be constructed of
aluminized steel and shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. The heat exchanger shall

13

528150-YTG-T-0514
be of the tubular type, constructed of T1-40 aluminized steel for
corrosion resistance and allowing minimum mixed air entering
temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminum-coated steel. All gas piping shall enter the
unit cabinet at a single location, through either the side or bottom, without any field modifications. An integrated control board
shall provide timed control of evaporator fan functioning and
burner ignition. Heating section shall be provided with the following minimum protection:
a. Primary and auxiliary high-temperature limit switches.
b. Induced draft pressure sensor.
c. Flame roll out switch (manual reset).
d. Flame proving controls.
e. All two stage gas units shall have two independent
stages of capacity (70% or 75% 1st stage, 100% 2nd
stage) 3 through 5 ton and (60% 1st stage, 100% 2nd
stage) 6-1/2 through 12-1/2 ton.
ELECTRIC HEATING SECTION (IF EQUIPPED)
An electric heating section, with nickel chromium elements,
shall be provided in a range of 3 thru 54KW. The heating section shall have a primary limit control(s) (automatic reset) to prevent the heating element system from operating at an
excessive temperature. The Heating Section assembly shall
slide out of the unit for easy maintenance and service. Units
with Electric Heating Sections shall be wired for a single point
power supply with branch circuit fusing (where required).
UNIT OPERATING CHARACTERISTICS
Unit shall be capable of starting and running at 125 ºF outdoor
temperature, exceeding maximum load criteria of AHRI Standard 340/360. The compressor, with standard controls, shall be
capable of operation down to 0 ºF outdoor temperature. Unit
shall be provided with fan time delay to prevent cold air delivery
before heat exchanger warms up. (Gas heat only)
ELECTRICAL REQUIREMENTS - All unit power wiring shall
enter unit cabinet at a single factory provided location and be
capable of side or bottom entry to minimize roof penetrations
and avoid unit field modifications. Separate side and bottom
openings shall be provided for the control wiring.
STANDARD LIMITED WARRANTIES - Compressor – 5 Years,
Heat Exchanger – 10 Years, Elect. Heat Elem. – 5 Years,
Parts – 1 Year
OPTIONAL OUTDOOR AIR (Shall be made available by either/
or):
• ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER
- Outdoor and return air dampers that are interlocked and
positioned by a fully-modulating, spring-return damper
actuator. The maximum leakage rate for the outdoor air
intake dampers shall be designed to meet ASHRAE 90.12010, AMCA 511 Class 1A damper, and the International
Energy Conservation Code (IECC) certification
requirements by achieving leakage rates of 3 cfm/sq. ft. at
1" of static pressure. During economizer operation, a

14

mixed-air temperature control shall modulate the outdoor
and return air damper assembly to prevent the supply air
temperature from dropping below 55°F. Changeover from
compressor to economizer operation shall be provided by
an integral electronic enthalpy control that feeds input into
the basic module. The outdoor intake opening shall be
covered with a rain hood that matches the exterior of the
unit. Water eliminator/filters shall be provided.
Simultaneous economizer/compressor operation is also
possible. Dampers shall fully close on power loss.
Available with barometric relief and power exhaust.
• MOTORIZED OUTDOOR AIR DAMPERS - Outdoor and
return air dampers that are interlocked and positioned by
a 2- position, spring-return damper actuator. A unitmounted potentiometer shall be provided to adjust the
outdoor and return air damper assembly to take in the
design CFM of outdoor air to meet the ventilation
requirements of the conditioned space during normal
operation. Whenever the indoor fan motor is energized,
the dampers open up to one of two pre-selected positions
- regardless of the outdoor air enthalpy. Dampers return to
the fully closed position when the indoor fan motor is deenergized. Dampers shall fully close on power loss.
ADDITIONAL FACTORY INSTALLED OPTIONS
• ALTERNATE INDOOR BLOWER MOTOR – For
applications with high restrictions, units are available with
optional indoor blower motors that provide higher static
output and/or higher airflow.
• VARIABLE AIR VOLUME (VAV) - The VAV option using
a variable frequency drive (VFD) shall be available on
6-1/2 through 12-1/2 ton models for applications requiring
a constant supply-duct static pressure. Units equipped for
VAV shall be controlled by a duct pressure transducer
with a 0 - 5" WC pressure range. The pressure transducer
shall provide a 0 - 5 VDC output signal to a VAV control
board which, in turn shall provide a 2 - 10 VDC speed
reference signal to the VFD. The VAV control board shall
operate using factory-installed Supply Air, Return Air and
Outside Air Temperature Sensors with a nominal
resistance of 10,000 Ohms. Units equipped with VFD's
shall have factory-installed manual bypass as an option.
• CONVENIENCE OUTLET (POWERED/NON-POWERED)–
Unit can be provided with an optional 120VAC GFCI outlet
with cover on the corner of the unit housing the compressors.
• ELECTRIC HEAT - Electric Heaters range from 3kW to
54kW and are available in all the voltage options of the
base unit.
• PHASE MONITOR - Designed to prevent damage in outof-phase condition.
• COIL GUARD - Designed to prevent condenser coil
damage.
• BAS CONTROLS - Include supply air sensor, return air
sensor, dirty filter indicator and air proving switch.
• DIRTY FILTER SWITCH – This kit includes a differential
pressure switch that energizes the fault light on the unit

Johnson Controls Unitary Products

528150-YTG-T-0514
thermostat, indicating that there is an abnormally highpressure drop across the filters.
• BREAKER – An HACR breaker can be factory installed
on gas heat units or cooling units with electric heat.
• DISCONNECT SWITCH - A disconnect can be factory
installed on a cooling only units sized for the largest
electric heat available.

• BAROMETRIC RELIEF DAMPER – (Unit mounted –
Downflow, Duct Mounted – Horizontal) – Contains a rain
hood, air inlet screen, exhaust damper and mounting
hardware. Used to relieve internal air pressure through
the unit during economizer operation.
• PROPANE CONVERSION KIT – Contains new orifices
and gas valve springs to convert from natural to L.P. gas.

• STAINLESS STEEL HEAT EXCHANGER – For
applications in a corrosive environment, this option
provides a full stainless steel heat exchanger assembly.

• -60ºF GAS HEAT KIT – Provides an electric heat kit for
the gas compartment for use in extreme low ambient
conditions.

• SMOKE DETECTOR – A smoke detector can be factory
mounted and wired in the supply and/or return air
compartments.

• ECONOMIZER (Downflow and Horizontal flow)

OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE

• POWER EXHAUST – (Unit mount – Downflow, Duct
mount – Horizontal flow)
• DUAL ENTHALPY KIT - Provides a second input to
economizer to monitor return air.

• ROOF CURB - 14” and 8” high, full perimeter knockdown
curb, with hinged design for quick assembly.

Johnson Controls Unitary Products

15

528150-YTG-T-0514

Physical Data
ZH037-061 Single Stage Gas Physical Data
Models

Component

ZH037

ZH049

ZH061

3.0

4.0

5.0

Gross Capacity @ AHRI A point (MBh)

37000

50000

61000

AHRI net capacity (MBh)

36000

48000

58000

11.8

11.8

11.8

SEER

14

14

14

IPLV

-

-

-

CFM

1200

1600

2000

System power (KW)

3.05

4.07

4.90

R-410A

R-410A

R-410A

System 1

7-4

6-14

7-12

System 2

-

-

-

Nominal Tonnage
AHRI COOLING PERFORMANCE

EER

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

A05

A07

A09

A05

A07

A09

A07

A09

A13

Heat input (K Btu)

60

80

120

60

80

120

80

120

160

Heat output (K Btu)

49

65

97

49

65

97

65

97

129

-

-

-

-

81

81.5

81

81

81

80.5

AFUE %

-

Steady state efficiency (%)

81.5

81

81

-

No. burners

4

4

6

4

4

6

4

6

8

No. stages

1

1

1

1

1

1

1

1

1

Temperature Rise Range (ºF)
Gas Limit Setting (ºF)
Gas piping connection (in.)

20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F
235°F

200°F

255°F

235°F

200°F

255°F

200°F

245°F

240°F

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

DIMENSIONS (inches)
Length

89

89

89

Width

59

59

59

Height

42

42

42

723

763

864

Recip

Recip

Recip

OPERATING WT. (lbs.)
COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)

1

1

1

100

100

100
21.1

CONDENSER COIL DATA
Face area (Sq. Ft.)

11.9

18.5

Rows

1

1

1

Fins per inch

23

23

23

Tube diameter (in./MM)
Circuitry Type

1/25

.71/18

.71/18

2-pass Microchannel

2-pass Microchannel

2-pass Microchannel
10.6

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

8

8

Rows

3

3

3

Fins per inch

15

15

15

Tube diameter

0.375

0.375

0.375

Refrigerant control

TXV

TXV

TXV

16

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH037-061 Single Stage Gas Physical Data (Continued)
Models

Component
Nominal Tonnage

ZH037

ZH049

ZH061

3.0

4.0

5.0

1

1

2

CONDENSER FAN DATA
Quantity of fans
Fan diameter (Inch)

24

24

24

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

1

1

2

1/3

1/3

1/3

Quantity of motors
Motor HP each
No. speeds

1

1

1

RPM

850

850

850

Total CFM

3300

3700

6700

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

12 x 9

12 x 9

12 x 9

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VM34

1VL44

1VM34

1VL44

1VL40

1VP56

Blower Sheave

AK69

AK69

AK56

AK56

AK61

AK74

Belt

A47

A47

A47

A47

A47

A51

Motor HP each

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

2

RPM

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

Frame size
FILTERS
Quantity - Size

4 - (24 x 16 x 2)1,2
3

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)1,2
3

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)1,2
4 - (24 x 16 x 4)3

1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value)
2. 2 In. Pleated, Optional, MERV 7.
3. 4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

17

528150-YTG-T-0514

ZH037-061 Two Stage Gas Physical Data
Models

Component

ZH037

ZH049

ZH061

3.0

4.0

5.0

Gross Capacity @ AHRI A point (MBh)

37000

50000

61000

AHRI net capacity (MBh)

36000

48000

58000

11.8

11.8

11.8

SEER

14

14

14

IPLV

-

-

-

CFM

1200

1600

2000

System power (KW)

3.05

4.07

4.90

R-410A

R-410A

R-410A

System 1

7-4

6-14

7-12

System 2

-

-

-

Nominal Tonnage
AHRI COOLING PERFORMANCE

EER

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

N05

N07

N09

N05

N07

N09

N07

N09

N13

Heat input (K Btu)

60

80

120

60

80

120

80

120

160

Heat output (K Btu)

49

65

97

49

65

97

65

97

129

-

-

-

-

81

81.5

81

81

81

80.5

AFUE %

-

Steady state efficiency (%)

81.5

81

81

-

No. burners

4

4

6

4

4

6

4

6

8

No. stages

21

22

22

21

22

22

22

22

22

Temperature Rise Range (ºF)
Gas Limit Setting (ºF)
Gas piping connection (in.)

20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F
235°F

200°F

255°F

235°F

200°F

255°F

200°F

245°F

240°F

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

DIMENSIONS (inches)
Length

89

89

89

Width

59

59

59

Height

42

42

42

723

763

864

Recip

Recip

Recip

OPERATING WT. (lbs.)
COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)

1

1

1

100

100

100
21.1

CONDENSER COIL DATA
Face area (Sq. Ft.)

11.9

18.5

Rows

1

1

1

Fins per inch

23

23

23

Tube diameter (in./MM)
Circuitry Type

1/25

.71/18

.71/18

2-pass Microchannel

2-pass Microchannel

2-pass Microchannel
10.6

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

8

8

Rows

3

3

3

Fins per inch

15

15

15

Tube diameter

0.375

0.375

0.375

Refrigerant control

TXV

TXV

TXV

18

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH037-061 Two Stage Gas Physical Data (Continued)
Models

Component
Nominal Tonnage

ZH037

ZH049

ZH061

3.0

4.0

5.0

1

1

2

CONDENSER FAN DATA
Quantity of fans
Fan diameter (Inch)

24

24

24

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

1

1

2

1/3

1/3

1/3

Quantity of motors
Motor HP each
No. speeds

1

1

1

RPM

850

850

850

Total CFM

3300

3700

6700

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

12 x 9

12 x 9

12 x 9

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VM34

1VL44

1VM34

1VL44

1VL40

1VP56

Blower Sheave

AK69

AK69

AK56

AK56

AK61

AK74

Belt

A47

A47

A47

A47

A47

A51

Motor HP each

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

2

RPM

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

Frame size
FILTERS
Quantity - Size
1.
2.
3.
4.
5.

4 - (24 x 16 x 2)3,4
5

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)3,4
5

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)3,4
4 - (24 x 16 x 4)5

1st Stage Capacity is 75% of Full Capacity.
1st Stage Capacity is 70% of Full Capacity.
2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value)
2 In. Pleated, Optional, MERV 7.
4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

19

528150-YTG-T-0514

ZH078-150 Physical Data
Models

Component

ZH078

ZH090

ZH102

ZH120

ZH150

6.5

7.5

8.5

10

12.5

Gross Capacity @ AHRI A point (Btu)

81000

93000

107000

125000

156000

AHRI net capacity (Btu)

78000

90000

102000

120000

150000

11.71/11.52

11.71/11.52

11.71/11.52

11.7

11.71/11.52

Nominal Tonnage
AHRI COOLING PERFORMANCE

EER
SEER

-

-

-

-

-

IEER

12.81/12.62

12.81/12.62

12.81/12.62

12

12.81/12.62

IPLV

13.7

13

13.5

12.9

14.1

CFM

2600

2700

3400

4000

3750

System power (KW)

6.69

7.70

9.0

10.40

12.80

R-410A

R-410A

R-410A

R-410A

R-410A

System 1

7-0

6-0

7-6

8-8

8-2

System 2

6-0

6-0

7-2

7-7

8-2

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

10

15

10

15

10

15

15

20

15

20

Heat input (K Btu)

120

180

120

180

120

180

180

240

180

240

Heat output (K Btu)

96

144

96

144

96

144

144

192

144

192

-

-

-

-

-

-

-

-

-

-

80

80

80

80

80

80

80

80

80

80

AFUE %
Steady state efficiency (%)
No. burners

4

6

4

6

4

6

6

8

6

8

No. stages

23

23

23

23

23

23

23

23

23

23

20-50

35-65

15-45

30-60

10-40

25-55

20-50

35-65

10-40

25-55

Gas Limit Setting (ºF)

165

165

165

165

215

195

195

160

195

160

Gas piping connection (in.)

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

Temperature Rise Range (ºF)

DIMENSIONS (inches)
Length

89

89

89

89

Width

59

59

59

59

59

Height

42

42

50-3/4

50-3/4

50-3/4

910

910

1047

1090

1280

Recip

Recip

Recip

Scroll

Scroll

2

2

2

2

2

50 / 100

50 / 100

50 / 100

50 / 100

50 / 100
47.5

OPERATING WT. (lbs.)

119-1/2

COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)
CONDENSER COIL DATA
Face area (Sq. Ft.)

23.8

23.8

29.0

29.0

Rows

1

1

1

1

1

Fins per inch

23

23

23

23

23

1/25

1/25

1/25

1/25

.71/18

Tube diameter (in./MM)
Circuitry Type

2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

10.6

10.6

13.2

13.2

Rows

3

3

3

4

13.2
4

Fins per inch

15

15

15

15

15

Tube diameter

0.375

0.375

0.375

0.375

0.375

Circuitry Type

Intertwined

Intertwined

Intertwined

Intertwined

Intertwined

TXV

TXV

TXV

TXV

TXV

Refrigerant control

20

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH078-150 Physical Data (Continued)
Models

Component

ZH078

ZH090

ZH102

ZH120

ZH150

6.5

7.5

8.5

10

12.5

2

2

2

2

4

Nominal Tonnage
CONDENSER FAN DATA
Quantity of fans
Fan diameter (Inch)

24

24

24

24

24

Type

Prop

Prop

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

Direct

Direct

2

2

2

2

4

1/3

3/4

3/4

3/4

1/3

Quantity of motors
Motor HP each
No. speeds

1

1

1

1

1

RPM

850

1110

1110

1110

850

Total CFM

6700

8600

9400

9400

14000

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

1

1

12 x 12

12 x 12

15 x 15

15 x 15

15 x 15

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VP56

Blower Sheave

AK74

AK64

AK74

AK61

AK94

AK74

AK84

AK74

AK74

BK77

Belt

A49

A49

A49

A49

A56

A54

A56

A54

A54

BX55

Motor HP each

1-1/2

2

1-1/2

3

2

3

2

3

3

5

RPM

1725

1725

1725

1725

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

56

56

56

184T

Frame size
FILTERS
Quantity - Size
1.
2.
3.
4.
5.
6.

4 - (24 x 16 x 2)4,5
4 - (24 x 16 x 4)

6

4 - (24 x 16 x 2)4,5
4 - (24 x 16 x 4)

6

4 - (24 x 20 x 2)4,5
6

4 - (24 x 20 x 4)

4 - (24 x 20 x 2)4,5
6

4 - (24 x 20 x 4)

4 - (24 x 20 x 2)4,5
4 - (24 x 20 x 4)6

Cooling Only Unit
Cooling Unit with Gas or Electric Heat
1st Stage 60% of Full Capacity.
2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3.
2 In. Pleated, Optional, MERV 7.
4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

21

528150-YTG-T-0514

ZJ037-061 Single Stage Gas Heat Physical Data
Models

Component

ZJ037

ZJ049

ZJ061

3.0

4.0

5.0

Gross Capacity @ AHRI A point (MBh)

37000

50000

62000

AHRI net capacity (MBh)

36000

48000

60000

12.2

12.2

12.2

SEER

15

15

15

IPLV

-

-

-

CFM

1300

1600

2000

System power (KW)

2.95

3.95

4.90

R-410A

R-410A

R-410A

System 1

6-12

7-8

8-4

System 2

-

-

-

Nominal Tonnage
AHRI COOLING PERFORMANCE

EER

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

A05

A07

A09

A05

A07

A09

A07

A09

A13

Heat input (K Btu)

60

80

120

60

80

120

80

120

160

Heat output (K Btu)

49

65

97

49

65

97

65

97

129

-

-

-

-

81

81.5

81

81

81

80.5

AFUE %

-

Steady state efficiency (%)

81.5

81

81

-

No. burners

4

4

6

4

4

6

4

6

8

No. stages

1

1

1

1

1

1

1

1

1

Temperature Rise Range (ºF)
Gas Limit Setting (ºF)
Gas piping connection (in.)

20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F
235°F

200°F

255°F

235°F

200°F

255°F

200°F

245°F

240°F

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

DIMENSIONS (inches)
Length

89

89

89

Width

59

59

59

Height

42

42

42

740

775

770

Recip

Recip

Recip

OPERATING WT. (lbs.)
COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)

1

1

1

100

100

100
23.8

CONDENSER COIL DATA
Face area (Sq. Ft.)

18.5

23.8

Rows

1

1

1

Fins per inch

23

23

23

Tube diameter (in./MM)
Circuitry Type

.71/18

.71/18

.71/18

2-pass Microchannel

2-pass Microchannel

2-pass Microchannel
10.5

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

7.9

10.5

Rows

3

3

3

Fins per inch

15

15

15

Tube diameter

0.375

0.375

0.375

Refrigerant control

TXV

TXV

TXV

22

Johnson Controls Unitary Products

528150-YTG-T-0514
ZJ037-061 Single Stage Gas Heat Physical Data (Continued)
Models

Component
Nominal Tonnage

ZJ037

ZJ049

ZJ061

3.0

4.0

5.0

1

1

2

CONDENSER FAN DATA
Quantity of fans
Fan diameter (Inch)

24

24

24

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

1

1

2

1/3

1/3

1/3

Quantity of motors
Motor HP each
No. speeds

1

1

1

RPM

850

850

850

Total CFM

3300

3700

6300

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

12 x 9

12 x 9

12 x 9

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VM34

1VL44

1VM34

1VL44

1VL40

1VP56

Blower Sheave

AK69

AK69

AK56

AK56

AK61

AK74

Belt

A47

A47

A47

A47

A47

A51

Motor HP each

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

2

RPM

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

Frame size
FILTERS
Quantity - Size

4 - (24 x 16 x 2)1,2
3

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)1,2
3

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)1,2
4 - (24 x 16 x 4)3

1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value)
2. 2 In. Pleated, Optional, MERV 7.
3. 4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

23

528150-YTG-T-0514

ZJ037-061 Two Stage Gas Heat Physical Data
Models

Component

ZJ037

ZJ049

ZJ061

3.0

4.0

5.0

Gross Capacity @ AHRI A point (MBh)

37000

50000

62000

AHRI net capacity (MBh)

36000

48000

60000

12.2

12.2

12.2

SEER

15

15

15

IPLV

-

-

-

CFM

1300

1600

2000

System power (KW)

2.95

3.95

4.90

R-410A

R-410A

R-410A

System 1

6-12

7-8

8-4

System 2

-

-

-

Nominal Tonnage
AHRI COOLING PERFORMANCE

EER

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

N05

N07

N09

N05

N07

N09

N07

N09

N13

Heat input (K Btu)

60

80

120

60

80

120

80

120

160

Heat output (K Btu)

49

65

97

49

65

97

65

97

129

-

-

-

-

81

81.5

81

81

81

80.5

AFUE %

-

Steady state efficiency (%)

81.5

81

81

-

No. burners

4

4

6

4

4

6

4

6

8

No. stages

21

22

22

21

22

22

22

22

22

Temperature Rise Range (ºF)
Gas Limit Setting (ºF)
Gas piping connection (in.)

20-50°F 25-65°F 50-80°F 20-50°F 25-65°F 40-70°F 25-65°F 35-65°F 45-75°F
235°F

200°F

255°F

235°F

200°F

255°F

200°F

245°F

240°F

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

DIMENSIONS (inches)
Length

89

89

89

Width

59

59

59

Height

42

42

42

740

775

770

Recip

Recip

Recip

OPERATING WT. (lbs.)
COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)

1

1

1

100

100

100
23.8

CONDENSER COIL DATA
Face area (Sq. Ft.)

18.5

23.8

Rows

1

1

1

Fins per inch

23

23

23

Tube diameter (in./MM)
Circuitry Type

.71/18

.71/18

.71/18

2-pass Microchannel

2-pass Microchannel

2-pass Microchannel
10.5

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

7.9

23.8

Rows

3

3

3

Fins per inch

15

15

15

Tube diameter

0.375

0.375

0.375

Refrigerant control

TXV

TXV

TXV

24

Johnson Controls Unitary Products

528150-YTG-T-0514
ZJ037-061 Two Stage Gas Heat Physical Data (Continued)
Models

Component
Nominal Tonnage

ZJ037

ZJ049

ZJ061

3.0

4.0

5.0

1

1

2

CONDENSER FAN DATA
Quantity of fans
Fan diameter (Inch)

24

24

24

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

1

1

2

1/3

1/3

1/3

Quantity of motors
Motor HP each
No. speeds

1

1

1

RPM

850

850

850

Total CFM

3300

3700

6300

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

12 x 9

12 x 9

12 x 9

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VM34

1VL44

1VM34

1VL44

1VL40

1VP56

Blower Sheave

AK69

AK69

AK56

AK56

AK61

AK74

Belt

A47

A47

A47

A47

A47

A51

Motor HP each

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

2

RPM

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

Frame size
FILTERS
Quantity - Size
1.
2.
3.
4.
5.

4 - (24 x 16 x 2)3,4
5

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)3,4
5

4 - (24 x 16 x 4)

4 - (24 x 16 x 2)3,4
4 - (24 x 16 x 4)5

1st Stage Capacity is 75% of Full Capacity.
1st Stage Capacity is 70% of Full Capacity.
2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value)
2 In. Pleated, Optional, MERV 7.
4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

25

528150-YTG-T-0514

ZJ078-150 Physical Data
Models

Component

ZJ078

ZJ090

ZJ102

ZJ120

ZJ150

6.5

7.5

8.5

10

12.5

Gross Capacity @ AHRI A point (Btu)

80000

93000

106000

124000

154000

AHRI net capacity (Btu)

78000

90000

102000

120000

150000

12.21/12.02

12.21/12.02

12.21/12.02

12.0

12.0

SEER

-

-

-

-

-

IEER

14.0

13.1

12.2

12.8

13

IPLV

14.9

14.18

13.6

13.4

14.1

CFM

2600

2400

2800

3400

3500

Nominal Tonnage
AHRI COOLING PERFORMANCE

EER

System power (KW)

6.40

7.38

8.30

9.80

12.50

R-410A

R-410A

R-410A

R-410A

R-410A

System 1

5-10

7-12

8-8

7-14

10-8

System 2

5-12

7-10

8-12

7-14

9-12

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

10

15

10

15

10

15

15

20

15

20

Heat input (K Btu)

120

180

120

180

120

180

180

240

180

240

Heat output (K Btu)

96

144

96

144

96

144

144

192

144

192

-

-

-

-

-

-

-

-

-

-

80

80

80

80

80

80

80

80

80

80

AFUE %
Steady state efficiency (%)
No. burners

4

6

4

6

4

6

6

8

6

8

No. stages

23

23

23

23

23

23

23

23

23

23

20-50

35-65

15-45

30-60

10-40

25-55

20-50

35-65

10-40

25-55

Gas Limit Setting (ºF)

165

165

165

165

215

195

195

160

195

160

Gas piping connection (in.)

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

Temperature Rise Range (ºF)

DIMENSIONS (inches)
Length

89

89

89

89

Width

59

59

59

59

59

Height

50-3/4

50-3/4

50-3/4

50-3/4

50-3/4

1030

1050

1060

1070

1280

Recip

Recip

Recip

Scroll

Scroll

2

2

2

2

2

50 / 100

50 / 100

50 / 100

50 / 100

50 / 100
47.5

OPERATING WT. (lbs.)

119-1/2

COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)
CONDENSER COIL DATA
Face area (Sq. Ft.)

29.0

23.8

29.0

29.0

Rows

1

1

1

1

1

Fins per inch

23

23

23

23

23

.71/18

1/25

1/25

1/25

.71/18

Tube diameter (in./MM)
Circuitry Type

2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

13.2

13.2

13.2

13.2

Rows

3

4

4

4

13.2
4

Fins per inch

15

15

15

15

15

Tube diameter

0.375

0.375

0.375

0.375

0.375

Circuitry Type

Intertwined

Intertwined

Intertwined

Intertwined

Intertwined

TXV

TXV

TXV

TXV

TXV

Refrigerant control

26

Johnson Controls Unitary Products

528150-YTG-T-0514
ZJ078-150 Physical Data (Continued)
Models

Component

ZJ078

ZJ090

ZJ102

ZJ120

ZJ150

6.5

7.5

8.5

10

12.5

2

2

2

2

4

Nominal Tonnage
CONDENSER FAN DATA
Quantity of fans
Fan diameter (Inch)

24

24

24

24

24

Type

Prop

Prop

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

Direct

Direct

2

2

2

2

4

1/3

3/4

3/4

3/4

1/3

Quantity of motors
Motor HP each
No. speeds

1

1

1

1

1

RPM

850

1110

1110

1110

850

Total CFM

7400

8000

9000

9400

14000

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

1

1

15 x 15

15 x 15

15 x 15

15 x 15

15 x 15

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VL40

1VM50

1VL40

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VP56

Blower Sheave

AK74

AK74

AK69

AK69

AK89

AK74

AK84

AK74

AK74

BK77

Belt

A53

A54

A52

A54

A56

A54

A56

A54

A54

BX55

Motor HP each

1-1/2

2

1-1/2

3

2

3

2

3

3

5

RPM

1725

1725

1725

1725

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

56

56

56

184T

Frame size
FILTERS
Quantity - Size
1.
2.
3.
4.
5.
6.

4 - (24 x 20 x 2)4,5
4 - (24 x 20 x 4)

6

4 - (24 x 20 x 2)4,5
4 - (24 x 20 x 4)

6

4 - (24 x 20 x 2)4,5
4 - (24 x 20 x 4)

6

4 - (24 x 20 x 2)4,5
4 - (24 x 20 x 4)

6

4 - (24 x 20 x 2)4,5
4 - (24 x 20 x 4)6

Cooling Only Unit
Cooling Unit with Gas or Electric Heat
1st Stage 60% of Full Capacity.
2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3.
2 In. Pleated, Optional, MERV 7.
4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

27

528150-YTG-T-0514

ZR037-061 Single Stage Gas Heat Physical Data
Models

Component
Nominal Tonnage

ZR037

ZR049

ZR061

3

4

5

AHRI COOLING PERFORMANCE
Gross Capacity @ AHRI A point (Btu)

36500

49000

62000

AHRI net capacity (Btu)

35500

47500

60000

12.2

12.2

12.2

15

15

14.7

EER
SEER
IPLV

-

-

-

CFM

1200

1600

2000

System power (KW)

2.88

3.32

4.83

R-410A

R-410A

R-410A

System 1

12-8

12-0

11-0

System 2

-

-

-

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

A05

A07

A09

A05

A07

A09

A07

A09

A13

Heat input (K Btu)

60

80

120

60

80

120

80

120

160

Heat output (K Btu)

49

65

97

49

65

97

65

97

129

-

-

-

-

81

81.5

81

81

81

80.5

AFUE %

-

Steady state efficiency (%)

81.5

81

81

-

No. burners

4

4

6

4

4

6

4

6

8

No. stages

1

1

1

1

1

1

1

1

1

Temperature Rise Range (ºF)
Gas Limit Setting (ºF)
Gas piping connection (in.)

20-50°F 25-65°F 35-80°F 20-50°F 25-65°F 35-80°F 25-65°F 35-80°F 45-75°F
200°F

235°F

290°F

200°F

235°F

290°F

235°F

290°F

240°F

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

DIMENSIONS (inches)
Length

89

89

Width

59

59

59

Height

42

42

42

867

880

867

Recip

Recip

Recip

1

1

1

100

100

100
11.9

OPERATING WT. (lbs.)

89

COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)
CONDENSER COIL DATA
Face area (Sq. Ft.)

11.9

11.9

Rows

1

1

1

Fins per inch

23

23

23

Tube diameter (in./MM)
Circuitry Type

.98/25

.98/25

.71/18 - .98/25

2-pass Microchannel

2-pass Microchannel

2-pass Microchannel
10.56

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

10.56

10.56

Rows

3

3

4

Fins per inch

15

15

12

Tube diameter

0.375

0.375

0.375

Refrigerant control

TXV

TXV

TXV
8.9

REHEAT COIL DATA
Face area (Sq. Ft.)

8.9

8.9

Rows

2

2

2

Fins per inch

15

15

15

Tube diameter
Refrigerant control

28

0.375

0.375

0.375

Solenoid

Solenoid

Solenoid

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR037-061 Single Stage Gas Heat Physical Data (Continued)
Models

Component
Nominal Tonnage

ZR037

ZR049

ZR061

3

4

5

CONDENSER FAN DATA
Quantity of fans

1

2

2

Fan diameter (Inch)

24

24

24

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

Quantity of motors

1

2

2

Motor HP each

1/3

1/3

1/3

No. speeds

Var.

Var.

Var.

RPM (max.)

850

850

850

Total CFM

3500

7000

7000

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

12 x 9

12 x 9

12 x 9

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VP34

1VL44

1VP34

1VL44

1VP34

1VL44

Blower Sheave

AK61

AK59

AK61

AK59

AK61

AK59

Belt

A47

A47

A47

A47

A47

A47

Motor HP each

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

2

RPM

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

Frame size
FILTERS
Quantity - Size

4 - (25 x 16 x 2)1, 2

4 - (25 x 16 x 2) 1, 2

4 - (25 x 16 x 2)1, 2

4 - (25 x 16 x 4) 3

4 - (25 x 16 x 4) 3

4 - (25 x 16 x 4) 3

1. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value)
2. 2 In. Pleated, Optional, MERV 7.
3. 4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

29

528150-YTG-T-0514

ZR037-061 Two Stage Gas Heat Physical Data
Models

Component
Nominal Tonnage

ZR037

ZR049

ZR061

3

4

5

AHRI COOLING PERFORMANCE
Gross Capacity @ AHRI A point (Btu)

36500

49000

62000

AHRI net capacity (Btu)

35500

47500

60000

12.2

12.2

12.2

15

15

14.7

EER
SEER
IPLV

-

-

-

CFM

1200

1600

System power (KW)

2.88

3.32

4.83

R-410A

R-410A

R-410A

Refrigerant type

2000

Refrigerant charge (lb-oz)
System 1

12-8

System 2

12-0

-

11-0

-

-

AHRI HEATING PERFORMANCE
Heating model

N05

N07

N09

N05

N07

N09

N07

N09

N13

Heat input (K Btu)

60

80

120

60

80

120

80

120

160

Heat output (K Btu)

49

65

97

49

65

97

65

97

129

-

-

-

-

81

81.5

81

81

81

80.5

AFUE %

-

Steady state efficiency (%)

81.5

81

81

-

No. burners

4

4

6

4

4

6

4

6

8

No. stages

21

22

22

21

22

22

22

22

22

20-50°F

25-65°F

35-80°F

20-50°F

200°F

235°F

290°F

200°F

235°F

290°F

235°F

290°F

240°F

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

Temperature Rise Range (ºF)
Gas Limit Setting (ºF)
Gas piping connection (in.)

25-65°F 35-80°F 25-65°F 35-80°F 45-75°F

DIMENSIONS (inches)
Length

89

89

Width

59

59

59

Height

42

42

42

867

880

867

Recip

Recip

Recip

1

1

1

100

100

100
11.9

OPERATING WT. (lbs.)

89

COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)
CONDENSER COIL DATA
Face area (Sq. Ft.)

11.9

11.9

Rows

1

1

1

Fins per inch

23

23

23

Tube diameter (in./MM)
Circuitry Type

.98/25

.98/25

.71/18 - .98/25

2-pass Microchannel

2-pass Microchannel

2-pass Microchannel
10.56

EVAPORATOR COIL DATA
Face area (Sq. Ft.)

10.56

10.56

Rows

3

3

4

Fins per inch

15

15

12

Tube diameter

0.375

0.375

0.375

Refrigerant control

TXV

TXV

TXV
8.9

REHEAT COIL DATA
Face area (Sq. Ft.)

8.9

8.9

Rows

2

2

2

Fins per inch

15

15

15

Tube diameter
Refrigerant control

30

0.375

0.375

0.375

Solenoid

Solenoid

Solenoid

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR037-061 Two Stage Gas Heat Physical Data (Continued)
Models

Component
Nominal Tonnage

ZR037

ZR049

ZR061

3

4

5

CONDENSER FAN DATA
Quantity of fans

1

2

2

Fan diameter (Inch)

24

24

24

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

Quantity of motors

1

2

2

Motor HP each

1/3

1/3

1/3

No. speeds

Var.

Var.

Var.

RPM

850

850

850

Total CFM

3500

7000

7000

BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

12 x 9

12 x 9

12 x 9

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VP34

1VL44

1VP34

1VL44

1VP34

1VL44

Blower Sheave

AK61

AK59

AK61

AK59

AK61

AK59

Belt

A47

A47

A47

A47

A47

A47

Motor HP each

1-1/2

1-1/2

1-1/2

1-1/2

1-1/2

2

RPM

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

Frame size
FILTERS
Quantity - Size

4 - (25 x 16 x 2)3,4
4 - (25 x 16 x

4)5

4 - (25 x 16 x 2)3,4
4 - (25 x 16 x

4)5

4 - (25 x 16 x 2)3,4
4 - (25 x 16 x 4)5

1. 1st Stage Capacity is 75% of Full Capacity.
2. 1st Stage Capacity is 70% of Full Capacity.
3. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value)
4. 2 In. Pleated, Optional, MERV 7.
5. 4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

31

528150-YTG-T-0514

ZR078-150 Physical Data
Models

Component

ZR078

ZR090

ZR102

ZR120

ZR150

6.5

7.5

8.5

10

12.5

Gross Capacity @ AHRI A point (Mbh)

80000

90000

105000

124000

157000

AHRI net capacity (Mbh)

Nominal Tonnage
AHRI COOLING PERFORMANCE

78000

87000

102000

120000

150000

EER

11.2

11.2

11.2

11.2

11.2

IEER

12.51/12.32

11.5

12.2

11.3

11.0

IPLV

13.0

CFM

2200

2775

3350

3750

4450

System power (KW)

6.96

7.77

9.11

10.71

13.39

R-410A

R-410A

R-410A

R-410A

R-410A

System 1

9-0

6-12

11-10

8-11

20-0

System 2

5-8

6-0

10-3

7-8

19-0

Refrigerant type
Refrigerant charge (lb-oz)

AHRI HEATING PERFORMANCE
Heating model

10

15

10

15

10

15

15

20

15

20

Heat input (K Btu)

120

180

120

180

120

180

180

240

180

240

Heat output (K Btu)

96

144

96

144

96

144

144

192

144

192

-

-

-

-

-

-

-

-

-

-

80

80

80

80

80

80

80

80

80

80

AFUE %
Steady state efficiency (%)
No. burners

4

6

4

6

4

6

6

8

6

8

No. stages

23

23

23

23

23

23

23

23

23

23

Temperature Rise Range (ºF)

20-50

35-65

15-45

30-60

10-40

25-55

20-50

35-65

10-40

25-55

Gas Limit Setting (ºF)

165

165

165

165

215

195

195

160

195

160

Gas piping connection (in.)

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

DIMENSIONS (inches)
Length

89

89

89

89

119-7/16

Width

59

59

59

59

59

Height

42

42

50-3/4

50-3/4

50-3/4

957

965

1200

1200

1465

Scroll

Scroll

Scroll

Scroll

Scroll

2

2

2

2

2

50 / 100

50 / 100

50 / 100

50 / 100

50 / 100

Face area (Sq. Ft.)

23.8

23.8

29.0

29.0

47.5

Rows

OPERATING WT. (lbs.)
COMPRESSORS
Type
Quantity
Unit Capacity Steps (%)
CONDENSER COIL DATA

2/1

1

2

1

2

Fins per inch

20

23

20

23

15

Tube diameter (in.)

3/8

-

3/8

-

3/8

-

1/25

-

1/25

-

Split-face

2-pass
Microchannel

Split-face

2-pass
Microchannel

Split-face

13.2

Tube diameter (in.)/MM
Circuitry Type
EVAPORATOR COIL DATA
Face area (Sq. Ft.)

10.6

10.6

13.2

13.2

Rows

3

3

4

4

4

Fins per inch

15

15

15

15

15

Tube diameter

3/8

3/8

3/8

3/8

3/8

Circuitry Type

Split-face

Split-face

Split-face

Split-face

Split-face

TXV

TXV

TXV

TXV

TXV

Refrigerant control

32

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR078-150 Physical Data (Continued)
Models

Component

ZR078

ZR090

ZR102

ZR120

ZR150

6.5

7.5

8.5

10

12.5

6.66

6.66

10

10

10

Nominal Tonnage
REHEAT COIL DATA
Face area (Sq. Ft.)
Rows

2

2

2

2

2

Fins per inch

13

13

13

13

13

Tube diameter (in.)

3/8

3/8

3/8

3/8

3/8

CONDENSER FAN DATA
Quantity of Fans

2

2

2

2

4

Fan diameter (Inch)

24

24

24

24

24

Type

Prop

Prop

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

Direct

Direct

Quantity of motors
Motor HP each

2

2

2

2

4

1/3

1/3

1/3

1/3

1/3

No. speeds

1

1

1

1

1

850

850

850

850

850

6800

6800

6800

6800

14000

RPM
Total CFM
BELT DRIVE EVAP FAN DATA
Quantity
Fan Size (Inch)
Type

1

1

1

1

1

12 x 12

12 x 12

15 x 15

15 x 15

15 x 15

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Centrifugal

Motor Sheave

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VM50

1VP56

Blower Sheave

AK74

AK64

AK74

AK61

AK89

AK74

AK84

AK74

AK74

BK77

Belt

A49

A49

A49

A49

A56

A54

A56

A54

A54

BX55

Motor HP each

1-1/2

2

1-1/2

3

2

3

2

3

3

5

RPM

1725

1725

1725

1725

1725

1725

1725

1725

1725

1725

56

56

56

56

56

56

56

56

56

184T

Frame size
FILTERS
Quantity - Size
1.
2.
3.
4.
5.
6.

4 - (24 x 16 x 2)4,5 4 - (24 x 16 x 2)4,5 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 2)4,5
4 - (24 x 16 x 4)6

4 - (24 x 16 x 4)6

4 - (24 x 20 x 4)6

4 - (24 x 20 x 4)6

4 - (24 x 20 x 4)6

Cooling Only or Cooling with Electric Heat Unit
Cooling with Gas Heat Unit
1st Stage 60% of 2nd Stage
2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3.
2 In. Pleated, Optional, MERV 7.
4 In. Pleated, Optional, MERV 13.

Johnson Controls Unitary Products

33

528150-YTG-T-0514

ZH/ZJ/ZR078-150 Unit Limitations
Unit Limitations
Size
(Tons)

037
(3)

049
(4)

061
(5)

078
(6.5)

090
(7.5)

102
(8.5)

120
(10)

150
(12.5)

34

Model

ZH/ZJ/ZR

ZH/ZJ/ZR

ZH/ZJ/ZR

ZH/ZJ/ZR

ZH/ZJ/ZR

ZH/ZJ/ZR

ZH/ZJ/ZR

ZH/ZJ/ZR

Unit Voltage

Applied Voltage

Outdoor DB Temp

Min

Max

Max (°F)

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

208/230-3-60

187

252

125

460-3-60

432

504

125

575-3-60

540

630

125

Johnson Controls Unitary Products

528150-YTG-T-0514

Capacity Performance
ZH037-150 Cooling Capacities
ZH037 (3.0 Ton)
Air on
Evaporator Coil
CFM

750

900

1050

1200

1350

1500

750

900

1050

1200

1350

1500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

49.1
44.4
39.6
35.4
51.2
46.2
41.3
36.9
35.4
53.3
48.1
43.0
38.3
36.8
55.4
50.0
44.6
39.8
38.3
50.1
44.7
39.9
38.3
50.1
44.8
39.9
38.4

2.3
2.2
2.2
2.3
2.2
2.2
2.2
2.3
2.3
2.2
2.2
2.2
2.3
2.3
2.2
2.2
2.2
2.3
2.2
2.2
2.2
2.3
2.2
2.2
2.2
2.3
2.3

20.2
25.1
30.0
35.4
22.9
28.2
33.6
36.9
35.4
25.5
31.4
37.3
38.3
36.8
28.2
34.6
41.0
39.8
38.3
37.2
42.9
39.9
38.3
39.7
44.8
39.9
38.4

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

44.0
39.0
34.1
29.8
45.2
40.1
35.1
30.6
30.9
46.5
41.2
36.0
31.5
31.8
47.7
42.3
37.0
32.3
32.6
42.9
37.5
32.7
33.0
43.4
37.9
33.1
33.5

2.7
2.7
2.7
2.6
2.7
2.7
2.7
2.7
2.7
2.8
2.7
2.7
2.7
2.7
2.8
2.8
2.8
2.7
2.7
2.8
2.7
2.7
2.7
2.8
2.7
2.7
2.7

18.0
22.7
27.4
29.8
20.3
25.4
30.5
30.6
30.9
22.5
28.1
33.7
31.5
31.8
24.7
30.8
36.9
32.3
32.6
33.6
37.4
32.7
33.0
36.3
37.9
33.1
33.5

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
16.8
13.4
46.5
2.5
21.7
18.4
15.0
41.7
2.5
26.6
23.3
19.9
16.5
36.9
2.5
32.8
27.8
24.5
21.1
17.8
32.6
2.5
18.8
14.8
48.2
2.5
24.2
20.2
16.1
43.2
2.5
29.6
25.6
21.5
17.5
38.2
2.5
35.1
30.6
26.5
22.5
18.5
33.7
2.5
35.4
32.4
28.4
24.3
20.3
33.2
2.5
20.8
16.1
49.9
2.5
26.7
22.0
17.3
44.7
2.5
32.6
27.9
23.2
18.5
39.5
2.5
37.5
33.3
28.6
23.9
19.2
34.9
2.5
36.8
35.3
30.6
25.9
21.2
34.3
2.5
22.8
17.5
51.5
2.5
29.2
23.8
18.4
46.2
2.5
35.6
30.2
24.8
19.4
40.8
2.5
39.8
36.1
30.7
25.3
19.9
36.1
2.5
38.3
38.3
32.9
27.5
22.1
35.5
2.5
31.3
25.4
19.5
46.5
2.5
38.1
32.2
26.3
20.4
41.1
2.5
39.9
38.0
32.1
26.3
20.4
36.3
2.5
38.3
38.3
32.4
26.6
20.7
35.7
2.5
33.4
27.0
20.6
46.8
2.5
40.6
34.2
27.8
21.5
41.3
2.5
39.9
39.9
33.6
27.2
20.8
36.5
2.5
38.4
38.4
32.0
25.6
19.2
35.9
2.5
95°F
14.7
11.3
40.2
3.0
19.3
16.0
12.6
35.5
2.9
24.0
20.7
17.3
13.9
30.8
2.9
29.8
24.7
21.4
18.0
14.7
27.0
2.8
16.3
12.4
41.2
3.0
21.5
17.6
13.6
36.4
3.0
26.6
22.7
18.8
14.9
31.5
2.9
30.6
27.2
23.3
19.4
15.4
27.7
2.9
30.9
28.0
24.1
20.2
16.2
28.2
2.9
18.0
13.5
42.2
3.0
23.6
19.1
14.7
37.2
3.0
29.2
24.8
20.3
15.8
32.3
3.0
31.5
29.7
25.2
20.7
16.2
28.3
2.9
31.8
30.5
26.1
21.6
17.1
28.9
2.9
19.7
14.7
43.2
3.1
25.8
20.7
15.7
38.1
3.0
31.8
26.8
21.8
16.7
33.1
3.0
32.3
32.1
27.1
22.0
17.0
29.0
2.9
32.6
33.1
28.0
23.0
17.9
29.6
2.9
27.9
22.3
16.6
38.5
3.0
34.4
28.8
23.2
17.5
33.4
3.0
32.7
32.6
27.0
21.3
15.7
29.3
2.9
33.0
33.3
27.6
22.0
16.4
29.9
2.9
30.1
23.8
17.6
39.0
3.0
37.1
30.8
24.6
18.4
33.8
3.0
33.1
33.1
26.9
20.7
14.4
29.6
2.9
33.5
33.5
27.2
21.0
14.8
30.2
2.9

90
19.1
23.9
28.7
32.6
21.6
26.8
32.1
33.7
33.2
24.0
29.8
35.5
34.9
34.3
26.5
32.7
38.9
36.1
35.5
35.4
40.1
36.3
35.7
38.0
41.3
36.5
35.9
15.8
21.2
26.6
27.0
18.9
23.8
28.7
27.7
28.2
21.9
26.4
30.9
28.3
28.9
24.9
28.9
33.0
29.0
29.6
31.7
33.4
29.3
29.9
34.4
33.8
29.6
30.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
15.7
12.4
20.5
17.2
13.8
25.3
22.0
18.6
15.2
31.3
26.3
22.9
19.6
17.6
13.6
22.8
18.9
14.9
28.1
24.1
20.2
16.2
32.9
28.9
24.9
20.9
33.2
30.2
26.2
22.3
19.4
14.8
25.2
20.6
16.0
30.9
26.3
21.7
17.1
34.5
31.5
26.9
22.3
34.3
32.9
28.3
23.7
21.3
16.1
27.5
22.3
17.1
33.7
28.5
23.3
18.1
36.1
34.1
28.9
23.7
35.5
35.7
30.5
25.2
29.6
23.8
18.1
36.3
30.5
24.7
19.0
36.3
35.3
29.6
23.8
35.7
35.8
30.0
24.3
31.7
25.4
19.1
38.8
32.5
26.2
19.9
36.5
36.5
30.2
23.9
35.9
35.9
29.6
23.3
105°F
13.5
10.2
18.0
14.7
11.4
22.4
19.2
15.9
12.7
27.0
23.2
20.0
16.7
15.0
11.2
20.0
16.2
12.4
24.9
21.1
17.3
13.5
27.7
25.6
21.8
17.9
28.2
26.0
22.2
18.4
16.6
12.3
22.0
17.6
13.3
27.4
23.0
18.7
14.3
28.3
27.9
23.5
19.2
28.9
28.4
24.0
19.7
18.2
13.3
24.0
19.1
14.2
29.9
25.0
20.1
15.1
29.0
30.2
25.3
20.4
29.6
30.7
25.8
20.9
26.2
20.7
15.2
31.6
27.0
21.5
16.0
29.3
29.9
24.4
18.9
29.9
30.5
25.0
19.5
28.3
22.2
16.1
33.4
29.0
22.9
16.8
29.6
29.6
23.6
17.5
30.2
30.2
24.1
18.0

65
16.2
17.0
18.3
17.7
19.2
18.5
20.0
18.0
18.5
17.6
17.0
13.5
14.1
14.6
14.8
15.3
15.5
16.0
13.4
14.0
11.4
11.9

35

528150-YTG-T-0514
ZH037 (3.0 Ton) (Continued)
Air on
Evaporator Coil
CFM

750

900

1050

1200

1350

1500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

36.4
31.9
27.4
24.2
37.2
32.6
28.0
24.7
25.4
37.9
33.2
28.6
25.2
26.0
38.7
33.9
29.1
25.7
26.5
34.2
29.4
25.9
26.7
34.5
29.7
26.2
26.9

3.3
3.2
3.1
3.0
3.3
3.2
3.2
3.1
3.1
3.3
3.2
3.2
3.1
3.1
3.3
3.3
3.2
3.1
3.1
3.3
3.2
3.1
3.1
3.3
3.2
3.2
3.2

13.7
19.7
25.8
24.2
17.4
22.2
26.9
24.7
25.4
21.2
24.6
28.0
25.2
26.0
25.0
27.1
29.1
25.7
26.5
29.8
29.4
25.9
26.7
32.5
29.7
26.2
26.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
12.3
9.1
32.6
3.5
16.6
13.4
10.3
28.4
3.4
20.9
17.7
14.6
11.4
24.1
3.4
24.2
21.7
18.6
15.4
12.3
21.4
3.2
13.8
10.1
33.1
3.6
18.5
14.8
11.1
28.8
3.5
23.2
19.5
15.8
12.1
24.5
3.4
24.7
23.9
20.2
16.5
12.8
21.7
3.3
25.4
24.0
20.3
16.6
12.9
22.7
3.3
15.2
11.0
33.7
3.6
20.4
16.2
11.9
29.2
3.5
25.6
21.3
17.1
12.9
24.8
3.4
25.2
26.1
21.9
17.6
13.4
22.1
3.3
26.0
26.2
22.0
17.7
13.5
23.0
3.3
16.7
11.9
34.2
3.6
22.3
17.5
12.7
29.7
3.5
27.9
23.1
18.3
13.6
25.2
3.4
25.7
28.3
23.5
18.8
14.0
22.4
3.3
26.5
28.4
23.6
18.9
14.1
23.4
3.3
24.4
19.1
13.7
29.9
3.6
28.8
25.2
19.8
14.4
25.4
3.5
25.9
27.2
21.9
16.5
11.2
22.5
3.3
26.7
27.7
22.3
17.0
11.6
23.5
3.4
26.5
20.6
14.7
30.1
3.6
29.7
27.2
21.2
15.3
25.5
3.5
26.2
26.2
20.2
14.3
8.3
22.7
3.4
26.9
26.9
21.0
15.1
9.1
23.7
3.4

90
12.4
18.2
24.1
21.4
16.7
20.6
24.5
21.7
22.7
20.9
22.9
24.8
22.1
23.0
25.2
25.2
25.2
22.4
23.4
27.9
25.4
22.5
23.5
30.1
25.5
22.7
23.7

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
10.7
8.1
15.2
12.2
9.1
19.3
16.3
13.2
10.2
21.4
21.4
17.2
14.1
12.5
8.9
17.0
13.4
9.8
21.5
17.9
14.4
10.8
21.7
21.7
18.7
15.1
22.7
22.0
18.4
14.8
14.2
9.7
18.8
14.7
10.6
23.7
19.6
15.5
11.4
22.1
22.1
20.2
16.1
23.0
23.0
19.9
15.8
15.9
10.5
20.6
15.9
11.3
25.2
21.3
16.6
12.0
22.4
22.4
21.8
17.1
23.4
23.4
21.5
16.8
22.7
17.4
12.2
25.4
23.3
18.1
12.9
22.5
22.5
19.3
14.1
23.5
23.5
19.7
14.4
24.8
19.0
13.2
25.5
25.4
19.6
13.8
22.7
22.7
16.9
11.1
23.7
23.7
17.9
12.1

65
11.1
11.5
11.3
12.0
11.7
12.5
12.2
8.9
9.2
5.3
6.3

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

36

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH049 (4.0 Ton)
Air on
Evaporator Coil
CFM

1000

1200

1400

1600

1800

2000

1000

1200

1400

1600

1800

2000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

65.4
59.2
53.0
47.0
68.3
61.8
55.3
49.1
48.9
71.2
64.4
57.7
51.1
51.0
74.1
67.1
60.0
53.2
53.1
69.2
62.0
54.9
54.8
71.4
63.9
56.6
56.5

3.0
3.0
2.9
2.9
3.0
3.0
2.9
2.9
2.9
3.0
3.0
2.9
2.9
2.9
3.0
3.0
2.9
2.9
2.9
3.0
3.0
3.0
2.9
3.1
3.0
3.0
3.0

28.0
34.8
41.6
47.0
30.8
38.0
45.3
49.1
48.9
33.6
41.3
49.0
51.1
51.0
36.4
44.6
52.8
53.2
53.1
48.1
58.3
54.9
54.8
51.6
63.9
56.6
56.5

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

55.3
49.9
44.5
39.3
57.5
51.9
46.4
40.9
40.6
59.8
54.0
48.2
42.5
42.2
62.0
56.0
50.0
44.1
43.8
57.6
51.4
45.3
45.0
59.1
52.7
46.5
46.2

3.6
3.6
3.5
3.4
3.6
3.6
3.5
3.4
3.5
3.7
3.6
3.6
3.5
3.5
3.7
3.6
3.6
3.5
3.5
3.7
3.6
3.5
3.6
3.7
3.7
3.6
3.6

22.2
28.9
35.5
39.3
25.1
32.4
39.8
40.9
40.6
27.9
35.9
44.0
42.5
42.2
30.8
39.5
48.2
44.1
43.8
42.7
50.5
45.3
45.0
46.0
52.7
46.5
46.2

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
23.5
19.1
60.3
3.3
30.3
25.9
21.4
54.5
3.3
37.1
32.7
28.3
23.8
48.8
3.2
47.0
40.3
35.9
31.4
27.0
43.1
3.2
25.6
20.4
62.9
3.3
32.9
27.7
22.5
56.9
3.3
40.1
35.0
29.8
24.6
50.9
3.2
49.1
43.1
38.0
32.8
27.6
45.0
3.2
48.9
47.1
42.0
36.8
31.6
44.8
3.2
27.7
21.8
65.5
3.3
35.4
29.5
23.6
59.2
3.3
43.1
37.3
31.4
25.5
52.9
3.2
51.1
46.0
40.1
34.2
28.3
46.8
3.2
51.0
50.3
44.4
38.5
32.6
46.6
3.2
29.8
23.2
68.1
3.4
38.0
31.4
24.7
61.5
3.3
46.1
39.5
32.9
26.3
55.0
3.3
53.2
48.8
42.1
35.5
28.9
48.7
3.2
53.1
53.4
46.8
40.2
33.5
48.4
3.2
40.9
33.6
26.4
63.4
3.4
49.6
42.4
35.2
28.0
56.7
3.3
54.9
52.7
45.5
38.3
31.1
50.1
3.3
54.8
54.9
47.7
40.5
33.3
49.9
3.2
43.7
35.9
28.1
65.2
3.4
53.1
45.3
37.5
29.7
58.3
3.3
56.6
56.6
48.8
41.0
33.2
51.6
3.3
56.5
56.5
48.6
40.8
33.0
51.4
3.3
95°F
18.0
13.8
50.6
4.0
24.7
20.5
16.3
45.4
3.9
31.3
27.1
22.9
18.7
40.1
3.8
39.3
33.9
29.7
25.5
21.3
36.2
3.7
20.1
15.2
52.4
4.0
27.5
22.6
17.6
47.0
3.9
34.8
29.9
25.0
20.0
41.5
3.8
40.9
37.3
32.4
27.4
22.5
37.5
3.7
40.6
37.4
32.4
27.5
22.6
37.1
3.7
22.3
16.6
54.3
4.0
30.3
24.6
19.0
48.6
3.9
38.3
32.6
27.0
21.3
43.0
3.8
42.5
40.7
35.1
29.4
23.7
38.8
3.8
42.2
40.8
35.1
29.5
23.8
38.4
3.8
24.4
18.0
56.1
4.1
33.1
26.7
20.3
50.2
4.0
41.8
35.4
29.0
22.6
44.4
3.9
44.1
44.1
37.8
31.4
25.0
40.1
3.8
43.8
44.2
37.8
31.5
25.1
39.7
3.8
35.7
28.7
21.7
51.6
4.0
45.1
38.0
31.0
24.0
45.6
3.9
45.3
45.3
38.3
31.3
24.3
41.2
3.8
45.0
45.2
38.2
31.2
24.2
40.8
3.8
38.3
30.7
23.0
53.0
4.1
48.3
40.7
33.0
25.3
46.8
4.0
46.5
46.5
38.9
31.2
23.6
42.2
3.9
46.2
46.2
38.6
30.9
23.2
41.8
3.9

90
25.1
31.8
38.6
43.1
27.9
35.2
42.5
45.0
44.8
30.7
38.6
46.5
46.8
46.6
33.6
42.0
50.5
48.7
48.4
45.4
54.4
50.1
49.9
48.8
58.3
51.6
51.4
19.3
26.7
34.2
36.2
22.9
30.1
37.3
37.5
37.1
26.6
33.5
40.4
38.8
38.4
30.3
36.9
43.5
40.1
39.7
40.1
45.2
41.2
40.8
43.3
46.8
42.2
41.8

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
20.8
16.4
27.5
23.2
18.9
34.2
29.9
25.6
21.3
43.1
37.1
32.8
28.5
22.9
17.8
30.2
25.1
20.1
37.5
32.4
27.4
22.3
45.0
40.2
35.2
30.1
44.8
42.3
37.2
32.2
25.0
19.2
32.9
27.1
21.3
40.7
35.0
29.2
23.4
46.8
43.3
37.6
31.8
46.6
45.5
39.8
34.0
27.1
20.6
35.5
29.0
22.5
44.0
37.5
31.0
24.5
48.7
46.5
40.0
33.5
48.4
48.8
42.3
35.8
38.3
31.2
24.0
47.4
40.2
33.1
26.0
50.1
49.0
41.9
34.8
49.9
50.1
43.0
35.8
41.0
33.3
25.6
50.7
43.0
35.2
27.5
51.6
51.6
43.9
36.1
51.4
51.4
43.6
35.9
105°F
16.2
12.1
22.7
18.6
14.5
29.1
25.1
21.0
16.9
36.2
30.9
26.9
22.8
18.2
13.4
25.3
20.5
15.7
32.5
27.7
22.9
18.1
37.5
34.2
29.4
24.6
37.1
33.8
29.0
24.2
20.1
14.6
28.0
22.5
17.0
35.8
30.3
24.8
19.3
38.8
37.4
31.9
26.4
38.4
37.0
31.4
25.9
22.1
15.9
30.6
24.4
18.2
39.2
32.9
26.7
20.5
40.1
40.7
34.4
28.2
39.7
40.2
33.9
27.7
33.2
26.3
19.5
41.9
35.5
28.6
21.8
41.2
41.5
34.6
27.7
40.8
41.0
34.1
27.2
35.8
28.3
20.7
44.6
38.1
30.6
23.1
42.2
42.2
34.7
27.2
41.8
41.8
34.3
26.8

65
24.1
25.1
27.1
26.0
28.2
27.0
29.3
27.7
28.7
28.4
28.1
18.7
19.8
19.4
20.9
20.4
22.0
21.5
20.8
20.4
19.6
19.2

37

528150-YTG-T-0514
ZH049 (4.0 Ton) (Continued)
Air on
Evaporator Coil
CFM

1000

1200

1400

1600

1800

2000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

46.0
40.8
35.6
33.1
47.4
42.0
36.7
34.0
33.6
48.7
43.2
37.8
35.0
34.6
50.1
44.4
38.8
36.0
35.5
45.6
39.9
37.0
36.5
46.8
40.9
37.9
37.4

4.3
4.2
4.1
4.0
4.4
4.2
4.1
4.0
4.0
4.4
4.3
4.1
4.1
4.1
4.4
4.3
4.2
4.1
4.1
4.4
4.2
4.1
4.1
4.4
4.3
4.2
4.2

16.4
24.6
32.8
33.1
20.8
27.8
34.8
34.0
33.6
25.3
31.0
36.8
35.0
34.6
29.7
34.3
38.8
36.0
35.5
37.5
39.9
37.0
36.5
40.6
40.9
37.9
37.4

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
14.3
10.4
41.4
4.7
20.6
16.7
12.7
36.3
4.5
26.9
23.0
19.0
15.1
31.2
4.3
33.1
28.0
24.1
20.1
16.2
29.9
4.3
16.2
11.5
42.3
4.7
23.1
18.5
13.8
37.1
4.5
30.1
25.5
20.8
16.2
31.9
4.4
34.0
31.1
26.4
21.8
17.1
30.6
4.3
33.6
30.2
25.5
20.8
16.2
30.1
4.3
18.0
12.6
43.2
4.8
25.7
20.3
14.9
37.9
4.6
33.3
28.0
22.6
17.2
32.5
4.4
35.0
34.1
28.8
23.4
18.0
31.3
4.3
34.6
33.1
27.8
22.4
17.0
30.7
4.3
19.9
13.8
44.1
4.8
28.2
22.1
16.0
38.7
4.6
36.5
30.5
24.4
18.3
33.2
4.4
36.0
37.2
31.1
25.0
19.0
31.9
4.4
35.5
36.1
30.0
23.9
17.9
31.4
4.4
30.7
24.0
17.2
39.7
4.7
38.7
33.0
26.3
19.6
34.1
4.5
37.0
37.6
30.8
24.1
17.4
32.8
4.4
36.5
36.8
30.0
23.3
16.5
32.2
4.4
33.2
25.8
18.4
40.7
4.8
40.9
35.6
28.2
20.8
35.0
4.6
37.9
37.9
30.5
23.1
15.7
33.6
4.5
37.4
37.4
30.0
22.6
15.2
33.1
4.5

90
13.7
22.4
31.2
29.9
19.1
25.5
31.9
30.6
30.1
24.6
28.6
32.5
31.3
30.7
30.1
31.7
33.2
31.9
31.4
34.8
34.1
32.8
32.2
38.0
35.0
33.6
33.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
12.1
8.7
18.6
14.8
11.0
24.7
20.9
17.1
13.2
29.9
25.1
21.3
17.5
14.2
9.7
21.0
16.5
11.9
27.8
23.3
18.7
14.2
30.6
28.0
23.5
19.0
30.1
26.6
22.0
17.5
16.2
10.7
23.4
18.1
12.9
30.8
25.6
20.4
15.2
31.3
30.9
25.6
20.4
30.7
29.3
24.1
18.8
18.3
11.7
25.7
19.8
13.9
33.2
28.0
22.1
16.2
31.9
31.9
27.8
21.9
31.4
31.4
26.1
20.2
28.2
21.6
15.0
34.1
30.5
23.9
17.3
32.8
32.8
27.1
20.5
32.2
32.2
25.9
19.3
30.7
23.4
16.2
35.0
33.0
25.8
18.5
33.6
33.6
26.4
19.1
33.1
33.1
25.8
18.5

65
13.7
14.4
13.0
15.2
13.6
16.0
14.2
13.9
12.7
11.8
11.2

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

38

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH061 (5.0 Ton)
Air on
Evaporator Coil
CFM

1250

1500

1750

2000

2250

2500

1250

1500

1750

2000

2250

2500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

82.5
74.3
66.2
59.3
84.7
76.3
68.0
60.9
61.6
86.9
78.4
69.8
62.5
63.3
89.2
80.4
71.6
64.1
64.9
83.6
74.5
66.7
67.5
86.9
77.3
69.3
70.0

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

36.6
43.9
51.1
59.3
40.0
48.4
56.7
60.9
61.6
43.5
52.8
62.2
62.5
63.3
47.0
57.3
67.7
64.1
64.9
61.7
72.5
66.7
67.5
66.1
77.3
69.3
70.0

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

69.3
62.3
55.2
49.7
71.7
64.4
57.1
51.4
48.8
74.0
66.5
58.9
53.0
50.4
76.3
68.6
60.8
54.7
52.0
68.8
61.0
54.9
52.2
69.0
61.2
55.0
52.3

4.3
4.3
4.2
4.1
4.3
4.3
4.2
4.2
4.2
4.3
4.3
4.2
4.2
4.2
4.4
4.3
4.2
4.2
4.2
4.3
4.2
4.2
4.2
4.3
4.2
4.2
4.2

29.2
37.9
46.5
49.7
33.3
42.3
51.3
51.4
48.8
37.3
46.7
56.0
53.0
50.4
41.4
51.1
60.8
54.7
52.0
55.2
61.0
54.9
52.2
59.4
61.2
55.0
52.3

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
30.6
25.1
75.9
3.9
38.3
32.8
27.3
68.3
3.8
46.0
40.5
35.0
29.4
60.7
3.8
59.3
49.5
43.9
38.4
32.9
54.5
3.8
33.6
27.1
78.2
3.9
41.9
35.4
29.0
70.4
3.9
50.2
43.8
37.3
30.8
62.5
3.8
60.9
53.4
47.0
40.5
34.1
56.1
3.8
61.6
54.9
48.4
41.9
35.5
55.2
3.8
36.5
29.1
80.5
3.9
45.5
38.1
30.7
72.4
3.9
54.4
47.0
39.6
32.2
64.4
3.8
62.5
57.4
50.0
42.6
35.2
57.8
3.8
63.3
58.9
51.6
44.2
36.8
56.8
3.8
39.5
31.2
82.7
3.9
49.0
40.7
32.4
74.5
3.9
58.6
50.3
41.9
33.6
66.2
3.8
64.1
61.4
53.1
44.7
36.4
59.4
3.8
64.9
63.0
54.7
46.4
38.1
58.5
3.8
52.7
43.6
34.5
76.2
3.9
62.9
53.8
44.7
35.7
67.7
3.8
66.7
65.3
56.3
47.2
38.1
60.8
3.8
67.5
66.5
57.5
48.4
39.3
59.8
3.8
56.3
46.5
36.6
77.9
3.9
67.3
57.3
47.5
37.7
69.3
3.8
69.3
69.3
59.5
49.6
39.8
62.2
3.8
70.0
70.0
60.2
50.4
40.5
61.2
3.8
95°F
24.1
18.6
62.5
4.7
32.4
26.9
21.4
55.9
4.6
40.6
35.1
29.6
24.1
49.4
4.6
49.7
43.0
37.5
32.0
26.5
44.7
4.5
26.8
20.4
64.8
4.8
35.8
29.4
23.0
58.0
4.7
44.8
38.4
32.0
25.6
51.1
4.6
51.4
47.1
40.6
34.2
27.8
46.3
4.5
48.8
46.3
39.8
33.4
27.0
44.1
4.5
29.5
22.2
67.1
4.8
39.3
31.9
24.6
60.0
4.7
49.1
41.7
34.4
27.0
52.9
4.6
53.0
51.1
43.8
36.4
29.0
47.9
4.5
50.4
50.2
42.9
35.5
28.2
45.7
4.5
32.2
23.9
69.3
4.8
42.8
34.5
26.2
62.0
4.7
53.3
45.0
36.8
28.5
54.7
4.6
54.7
55.2
46.9
38.6
30.3
49.6
4.5
52.0
54.2
45.9
37.7
29.4
47.2
4.5
46.0
36.9
27.7
62.0
4.7
57.3
48.2
39.0
29.8
54.7
4.6
54.9
55.1
45.9
36.7
27.6
49.5
4.5
52.2
53.3
44.1
34.9
25.7
47.2
4.6
49.3
39.2
29.2
62.0
4.7
61.2
51.3
41.2
31.1
54.7
4.6
55.0
55.0
45.0
34.9
24.8
49.5
4.5
52.3
52.3
42.3
32.2
22.1
47.2
4.6

90
32.9
40.9
48.8
54.5
36.6
45.3
54.0
56.1
55.2
40.4
49.8
59.1
57.8
56.8
44.2
54.2
64.3
59.4
58.5
58.5
66.8
60.8
59.8
62.7
69.3
62.2
61.2
25.5
35.3
45.0
44.7
31.0
39.6
48.2
46.3
44.1
36.5
44.0
51.5
47.9
45.7
42.0
48.4
54.7
49.6
47.2
52.4
54.7
49.5
47.2
56.4
54.7
49.5
47.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
27.4
21.9
35.3
29.8
24.3
43.3
37.8
32.3
26.8
54.5
46.2
40.7
35.2
30.2
23.8
38.9
32.4
26.0
47.5
41.1
34.6
28.2
56.1
50.2
43.8
37.4
55.2
50.6
44.1
37.7
33.0
25.7
42.4
35.0
27.6
51.7
44.4
37.0
29.6
57.8
54.3
46.9
39.5
56.8
54.6
47.2
39.8
35.9
27.6
45.9
37.6
29.3
56.0
47.7
39.3
31.0
59.4
58.3
50.0
41.7
58.5
58.6
50.3
42.0
49.3
40.2
31.1
60.1
51.0
41.9
32.7
60.8
60.2
51.1
42.0
59.8
59.9
50.8
41.7
52.8
42.8
32.9
64.2
54.3
44.4
34.4
62.2
62.2
52.2
42.3
61.2
61.2
51.2
41.3
105°F
21.7
16.3
29.9
24.5
19.0
38.1
32.6
27.2
21.8
44.7
40.1
34.7
29.3
24.3
17.9
33.3
26.9
20.5
42.3
35.9
29.5
23.2
46.3
44.2
37.8
31.4
44.1
42.1
35.7
29.4
26.8
19.5
36.7
29.3
22.0
46.5
39.2
31.8
24.5
47.9
48.3
40.9
33.6
45.7
45.9
38.6
31.3
29.4
21.1
40.1
31.8
23.5
50.7
42.4
34.1
25.9
49.6
52.4
44.1
35.8
47.2
49.7
41.4
33.2
43.2
34.0
24.9
52.7
45.5
36.3
27.1
49.5
50.9
41.8
32.6
47.2
48.5
39.3
30.1
46.4
36.3
26.3
54.7
48.5
38.5
28.4
49.5
49.5
39.5
29.4
47.2
47.2
37.1
27.1

65
29.7
30.9
31.2
32.1
32.5
33.4
33.7
32.8
32.5
32.3
31.3
23.8
25.1
23.0
26.3
23.9
27.5
24.9
23.4
21.0
19.4
17.0

39

528150-YTG-T-0514
ZH061 (5.0 Ton) (Continued)
Air on
Evaporator Coil
CFM

1250

1500

1750

2000

2250

2500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

55.7
49.6
43.5
39.7
57.9
51.6
45.2
41.3
39.4
60.1
53.5
46.9
42.8
40.9
62.3
55.5
48.6
44.4
42.4
55.2
48.4
44.2
42.2
54.9
48.2
44.0
42.0

5.2
5.0
4.9
4.8
5.2
5.1
4.9
4.8
4.9
5.2
5.1
5.0
4.9
4.9
5.3
5.1
5.0
4.9
4.9
5.1
5.0
4.9
4.9
5.2
5.0
4.9
5.0

21.9
32.7
43.5
39.7
28.8
37.0
45.2
41.3
39.4
35.7
41.3
46.9
42.8
40.9
42.7
45.6
48.6
44.4
42.4
49.5
48.4
44.2
42.2
53.5
48.2
44.0
42.0

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
19.2
13.9
48.9
5.6
27.4
22.0
16.7
43.3
5.4
35.5
30.2
24.9
19.5
37.6
5.3
39.7
37.2
31.8
26.5
21.2
34.7
5.1
21.7
15.4
51.1
5.6
30.7
24.4
18.1
45.2
5.5
39.7
33.4
27.1
20.8
39.2
5.3
41.3
41.3
35.0
28.7
22.3
36.2
5.2
39.4
37.9
31.6
25.3
19.0
34.7
5.2
24.1
16.8
53.2
5.7
34.0
26.7
19.4
47.1
5.5
43.9
36.6
29.3
22.0
40.9
5.3
42.8
45.4
38.1
30.8
23.5
37.8
5.2
40.9
41.6
34.3
27.0
19.7
36.2
5.3
26.6
18.3
55.4
5.7
37.4
29.1
20.8
49.0
5.5
48.1
39.8
31.5
23.3
42.5
5.4
44.4
49.5
41.2
33.0
24.7
39.3
5.2
42.4
45.2
36.9
28.7
20.4
37.6
5.3
40.4
31.2
22.1
48.4
5.6
48.1
42.8
33.6
24.5
42.1
5.4
44.2
46.7
37.6
28.4
19.3
38.9
5.3
42.2
43.6
34.5
25.3
16.2
37.2
5.3
43.4
33.4
23.4
47.9
5.6
48.2
45.7
35.7
25.7
41.6
5.4
44.0
44.0
34.0
23.9
13.9
38.5
5.3
42.0
42.0
32.0
22.0
11.9
36.9
5.4

90
22.6
30.1
37.6
34.7
29.5
34.4
39.2
36.2
34.7
36.4
38.6
40.9
37.8
36.2
43.3
42.9
42.5
39.3
37.6
46.7
42.1
38.9
37.2
47.9
41.6
38.5
36.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
15.3
11.5
24.9
19.6
14.4
33.4
27.7
22.5
17.3
34.7
34.7
29.0
23.8
19.1
12.9
28.1
21.9
15.6
37.1
30.9
24.6
18.4
36.2
36.2
32.1
25.9
34.7
33.8
27.5
21.3
22.9
14.2
31.4
24.1
16.9
40.9
34.1
26.8
19.5
37.8
37.8
35.3
28.0
36.2
36.2
30.0
22.7
26.7
15.5
34.6
26.4
18.1
42.5
37.2
28.9
20.7
39.3
39.3
38.4
30.1
37.6
37.6
32.4
24.2
37.6
28.4
19.3
42.1
40.1
31.0
21.8
38.9
38.9
33.4
24.3
37.2
37.2
29.6
20.5
40.5
30.5
20.5
41.6
41.6
33.0
23.0
38.5
38.5
28.4
18.4
36.9
36.9
26.8
16.8

65
18.5
19.6
15.0
20.7
15.5
21.9
15.9
15.1
11.4
8.4
6.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

40

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH078 (6.5 Ton)
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

1625

1950

2275

2600

2925

3250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

100.1
92.7
85.4
74.8
105.7
97.9
90.1
79.0
77.8
111.4
103.1
94.8
83.3
82.0
117.0
108.3
99.5
87.5
86.2
110.3
101.4
89.1
87.7
112.3
103.3
90.7
89.3

4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.8
4.7
4.7
4.7
4.7
4.8
4.7
4.7
4.7
4.8
4.7
4.7
4.7
4.7
4.7
4.7

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

96.1
86.0
75.9
70.3
98.3
88.0
77.7
71.9
72.8
100.5
89.9
79.4
73.5
74.5
102.6
91.9
81.1
75.1
76.1
95.2
84.0
77.8
78.8
98.5
87.0
80.5
81.6

5.9
5.8
5.8
5.8
6.0
5.9
5.8
5.8
5.7
6.0
5.9
5.8
5.8
5.7
6.0
5.9
5.8
5.8
5.8
5.9
5.8
5.8
5.8
5.9
5.9
5.9
5.8

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
90
85
80
75
70
65
75°F
38.5
33.6
28.8
98.1
5.3
49.4
44.5
39.7
34.9
89.4
5.3
60.2
55.4
50.6
45.7
40.9
80.6
5.2
74.8
69.6
61.2
56.4
51.6
46.7
72.6
5.2
47.6
39.7
31.8
102.0
5.3
59.7
51.8
43.9
35.9
92.9
5.3
71.7
63.8
55.9
48.0
40.1
83.9
5.3
79.0
75.6
67.6
59.7
51.8
43.9
75.5
5.2
77.8
79.4
72.1
64.2
56.3
48.4
75.3
5.2
56.8
45.8
34.8
105.9
5.3
70.0
59.0
48.0
37.0
96.5
5.3
83.2
72.2
61.2
50.2
39.2
87.1
5.3
83.3
81.5
74.1
63.1
52.1
41.1
78.4
5.2
82.0
82.8
78.9
67.9
56.9
46.0
78.2
5.2
66.0
51.9
37.8
109.8
5.3
80.3
66.2
52.2
38.1
100.1
5.3
94.6
80.5
66.5
52.4
38.4
90.3
5.3
87.5
87.5
80.5
66.4
52.4
38.3
81.3
5.2
86.2
86.2
85.7
71.7
57.6
43.6
81.1
5.2
82.3
69.0
55.6
42.3
102.7
5.3
99.0
84.2
70.9
57.6
44.2
92.7
5.3
89.1
89.1
85.6
72.3
58.9
45.6
83.4
5.3
87.7
87.7
87.5
74.2
60.9
47.5
83.3
5.2
84.4
71.7
59.1
46.5
105.4
5.3
103.3 88.0
75.3
62.7
50.1
95.1
5.3
90.7
90.7
90.7
78.1
65.5
52.8
85.6
5.3
89.3
89.3
89.3
76.7
64.1
51.4
85.4
5.3
95°F
41.0
32.2
23.5
87.2
6.5
52.3
43.5
34.8
26.0
78.4
6.3
63.6
54.8
46.1
37.3
28.6
69.5
6.2
70.3
67.6
56.5
47.7
39.0
30.2
63.1
6.1
41.8
33.8
25.8
89.3
6.5
54.3
46.2
38.2
30.2
80.2
6.4
66.7
58.7
50.6
42.6
34.6
71.2
6.3
71.9
70.1
62.1
54.1
46.0
38.0
64.6
6.2
72.8
71.3
63.3
55.3
47.2
39.2
67.1
6.2
42.7
35.4
28.1
91.3
6.5
56.3
49.0
41.7
34.4
82.1
6.4
69.8
62.5
55.2
47.9
40.6
72.8
6.3
73.5
72.6
67.7
60.4
53.1
45.8
66.1
6.2
74.5
73.7
69.0
61.7
54.4
47.1
68.7
6.2
43.6
37.0
30.4
93.4
6.5
58.2
51.7
45.1
38.5
83.9
6.4
72.9
66.3
59.8
53.2
46.6
74.5
6.3
75.1
75.1
73.3
66.7
60.2
53.6
67.5
6.2
76.1
76.1
74.7
68.1
61.6
55.0
70.2
6.2
66.8
57.4
48.0
38.7
86.3
6.5
79.9
73.0
63.7
54.3
45.0
76.6
6.3
77.8
77.8
76.9
67.5
58.2
48.8
69.4
6.2
78.8
78.8
78.1
68.8
59.4
50.1
72.2
6.3
75.3
63.1
51.0
38.8
88.6
6.5
87.0
79.7
67.6
55.4
43.3
78.6
6.4
80.5
80.5
80.5
68.4
56.2
44.1
71.3
6.3
81.6
81.6
81.6
69.4
57.3
45.1
74.1
6.3

90
39.7
50.8
61.9
72.6
44.7
57.0
69.2
75.5
75.3
49.8
63.1
76.5
78.4
78.2
54.8
69.3
83.8
81.3
81.1
74.5
89.4
83.4
83.3
79.8
95.1
85.6
85.4
36.1
48.5
60.8
63.1
39.9
51.9
64.0
64.6
67.1
43.6
55.4
67.2
66.1
68.7
47.4
58.9
70.4
67.5
70.2
65.6
74.5
69.4
72.2
72.3
78.6
71.3
74.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
32.9
26.1
44.0
37.2
30.4
55.1
48.3
41.5
34.7
68.6
58.8
52.1
45.3
36.8
28.8
49.0
41.0
33.1
61.2
53.3
45.3
37.3
72.8
64.9
56.9
48.9
75.3
67.7
59.7
51.7
40.6
31.5
54.0
44.8
35.7
67.3
58.2
49.1
39.9
77.1
70.9
61.7
52.6
78.2
74.0
64.8
55.7
44.5
34.1
58.9
48.6
38.3
73.4
63.1
52.8
42.5
81.3
76.9
66.6
56.3
81.1
80.2
69.9
59.6
63.2
51.8
40.5
78.6
67.3
55.9
44.6
83.4
81.2
69.9
58.5
83.3
82.8
71.5
60.1
67.4
55.0
42.7
83.8
71.4
59.1
46.7
85.6
85.6
73.2
60.8
85.4
85.4
73.1
60.7
105°F
29.5
21.5
40.4
32.4
24.4
51.4
43.4
35.4
27.4
61.7
53.8
45.8
37.8
31.7
23.6
43.8
35.7
27.6
55.9
47.8
39.7
31.5
63.7
59.2
51.1
43.0
66.3
58.2
50.1
41.9
34.0
25.8
47.2
38.9
30.7
60.4
52.1
43.9
35.7
65.6
64.6
56.4
48.1
68.3
63.5
55.3
47.0
36.3
27.9
50.6
42.2
33.8
64.8
56.5
48.1
39.8
67.5
70.0
61.6
53.3
70.2
68.8
60.5
52.1
55.3
45.1
34.8
69.9
60.4
50.1
39.9
69.4
70.7
60.4
50.2
72.2
71.5
61.2
51.0
60.1
48.0
35.8
75.0
64.2
52.1
40.0
71.3
71.3
59.2
47.1
74.1
74.1
62.0
49.9

65
38.5
41.0
43.8
43.5
46.5
45.9
49.3
47.2
48.8
48.4
48.3
29.8
34.8
33.8
39.9
38.8
44.9
43.7
39.9
40.7
34.9
37.7

41

528150-YTG-T-0514
ZH078 (6.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

78.3
70.7
63.2
55.8
80.3
72.5
64.7
57.2
61.4
82.2
74.2
66.3
58.6
62.9
84.1
76.0
67.9
60.0
64.4
77.4
69.1
61.1
65.6
78.8
70.3
62.2
66.7

7.0
6.8
6.7
6.5
7.0
6.9
6.7
6.6
6.6
7.1
6.9
6.8
6.6
6.7
7.1
7.0
6.8
6.6
6.7
7.0
6.8
6.7
6.7
7.0
6.9
6.7
6.8

31.2
44.7
58.1
55.8
37.9
49.6
61.4
57.2
61.4
44.6
54.6
64.6
58.6
62.9
51.3
59.6
67.9
60.0
64.4
64.4
69.1
61.1
65.6
69.2
70.3
62.2
66.7

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
26.7
19.5
69.4
7.5
37.4
30.1
22.9
63.1
7.3
48.0
40.8
33.5
26.2
56.8
7.1
55.8
51.1
43.9
36.6
29.3
48.6
6.9
29.7
21.4
71.3
7.6
41.4
33.2
24.9
64.8
7.4
53.1
44.9
36.7
28.5
58.3
7.2
57.2
56.3
48.1
39.9
31.6
49.9
6.9
61.3
53.1
44.9
36.7
28.4
55.7
7.1
32.6
23.4
73.1
7.6
45.4
36.2
27.0
66.4
7.4
58.2
49.1
39.9
30.7
59.7
7.3
58.6
61.5
52.3
43.1
34.0
51.2
7.0
62.9
58.0
48.8
39.6
30.5
57.1
7.1
35.5
25.4
74.9
7.7
49.4
39.3
29.1
68.1
7.5
63.3
53.2
43.1
32.9
61.2
7.3
60.0
66.7
56.6
46.4
36.3
52.4
7.1
64.4
62.9
52.8
42.6
32.5
58.5
7.2
53.3
42.1
31.0
68.5
7.5
66.8
57.0
45.9
34.8
61.6
7.3
61.1
64.4
53.3
42.2
31.0
52.7
7.1
65.6
64.8
53.7
42.5
31.4
58.9
7.2
57.1
45.0
32.9
68.9
7.6
70.3
60.9
48.8
36.6
62.0
7.4
62.2
62.2
50.0
37.9
25.8
53.0
7.1
66.7
66.7
54.6
42.5
30.3
59.3
7.2

90
24.9
40.9
56.8
48.6
36.4
47.3
58.3
49.9
55.7
47.8
53.8
59.7
51.2
57.1
59.3
60.2
61.2
52.4
58.5
63.2
61.6
52.7
58.9
66.2
62.0
53.0
59.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
23.7
17.5
34.3
27.8
21.3
44.7
38.1
31.6
25.1
48.6
48.6
41.9
35.4
27.6
19.3
39.0
30.7
22.3
50.4
42.1
33.7
25.4
49.9
49.9
45.1
36.8
55.7
48.0
39.7
31.4
31.5
21.1
43.6
33.5
23.4
56.1
46.0
35.9
25.7
51.2
51.2
48.3
38.2
57.1
52.5
42.4
32.3
35.4
22.9
48.3
36.4
24.5
61.2
49.9
38.0
26.0
52.4
52.4
51.5
39.6
58.5
57.0
45.1
33.1
51.2
39.2
27.2
61.6
53.7
41.7
29.7
52.7
52.7
46.2
34.2
58.9
58.2
46.1
34.1
54.1
42.0
29.9
62.0
57.6
45.5
33.3
53.0
53.0
40.9
28.8
59.3
59.3
47.2
35.1

65
28.9
28.5
23.1
28.0
22.1
27.6
21.2
22.1
22.1
16.7
23.0

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

42

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH090 (7.5 Ton)
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

1875

2250

2625

3000

3375

3750

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

113.8
106.0
98.1
86.5
121.4
112.9
104.5
92.2
90.4
128.9
119.9
110.9
97.9
96.1
136.5
126.9
117.3
103.6
101.8
128.9
119.1
105.2
103.4
130.9
121.0
106.8
104.9

5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.9
5.9
5.8
5.8
5.8
5.9
5.9
5.9
5.8
5.8
5.9
5.8
5.8
5.8
5.8
5.8

49.0
62.6
76.2
86.5
54.8
69.7
84.6
92.2
90.4
60.6
76.8
93.0
97.9
96.1
66.4
83.9
101.4
103.6
101.8
88.3
110.1
105.2
103.4
92.7
118.7
106.8
104.9

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

110.3
99.9
89.5
81.3
112.2
101.6
91.0
82.7
84.9
114.1
103.3
92.5
84.1
86.3
115.9
105.0
94.0
85.5
87.8
108.3
97.0
88.2
90.5
111.6
100.0
90.9
93.3

7.1
7.0
7.0
6.9
7.1
7.1
7.0
6.9
6.9
7.2
7.1
7.0
6.9
6.9
7.2
7.1
7.1
7.0
7.0
7.1
7.1
7.0
7.0
7.2
7.1
7.0
7.0

44.2
57.2
70.2
81.3
49.0
63.2
77.4
82.7
84.9
53.8
69.2
84.6
84.1
86.3
58.6
75.2
91.7
85.5
87.8
81.4
95.9
88.2
90.5
87.7
100.0
90.9
93.3

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
41.0
33.1
112.1
6.5
54.6
46.7
38.7
102.9
6.4
68.3
60.3
52.3
44.4
93.8
6.4
80.4
71.9
64.0
56.0
48.1
83.9
6.4
45.5
36.3
116.8
6.5
60.4
51.2
41.9
107.3
6.4
75.3
66.1
56.8
47.5
97.7
6.4
88.1
78.8
69.6
60.3
51.0
87.5
6.4
91.7
85.4
76.2
66.9
57.6
87.7
6.4
50.0
39.4
121.5
6.5
66.2
55.6
45.0
111.6
6.5
82.4
71.9
61.3
50.7
101.7
6.4
95.8
85.7
75.1
64.5
54.0
91.0
6.4
96.8
92.9
82.3
71.7
61.1
91.2
6.4
54.5
42.6
126.2
6.5
72.0
60.1
48.2
115.9
6.5
89.5
77.6
65.7
53.8
105.6
6.5
103.6 92.6
80.7
68.8
56.9
94.5
6.4
101.8 100.4 88.5
76.6
64.6
94.8
6.4
75.7
63.2
50.6
118.6
6.5
94.1
81.6
69.0
56.4
108.1
6.5
105.2 99.6
87.0
74.4
61.8
96.7
6.4
103.4 102.6 90.1
77.5
64.9
96.9
6.4
79.5
66.2
53.0
121.2
6.5
98.7
85.5
72.2
59.0
110.5
6.5
106.8 106.5 93.2
80.0
66.7
98.9
6.4
104.9 104.9 91.7
78.4
65.2
99.1
6.4
95°F
36.2
28.1
103.5
7.7
49.2
41.1
33.0
93.1
7.6
62.2
54.1
46.0
37.9
82.7
7.5
77.5
65.0
57.0
48.9
40.8
78.3
7.4
39.8
30.7
103.5
7.8
54.0
44.9
35.7
93.1
7.7
68.2
59.1
49.9
40.7
82.7
7.5
80.2
71.0
61.8
52.7
43.5
78.2
7.4
83.7
74.5
65.3
56.1
47.0
80.0
7.4
43.5
33.2
103.5
7.8
58.9
48.6
38.4
93.1
7.7
74.3
64.0
53.8
43.5
82.7
7.6
82.8
77.0
66.7
56.4
46.2
78.2
7.5
85.7
80.8
70.5
60.2
49.9
79.9
7.5
47.2
35.8
103.4
7.9
63.8
52.4
41.0
93.1
7.7
80.4
69.0
57.6
46.3
82.7
7.6
85.5
83.0
71.6
60.2
48.8
78.1
7.5
87.8
87.0
75.7
64.3
52.9
79.9
7.5
68.9
56.4
43.8
97.2
7.8
86.7
74.2
61.7
49.1
86.4
7.6
88.2
86.9
74.4
61.9
49.3
81.6
7.5
90.5
90.2
77.7
65.1
52.6
83.5
7.5
74.0
60.3
46.6
101.3
7.8
93.1
79.4
65.7
52.0
90.0
7.7
90.9
90.9
77.2
63.5
49.9
85.1
7.5
93.3
93.3
79.7
66.0
52.3
87.0
7.5

90
46.6
59.9
73.2
83.9
51.9
66.5
81.0
87.5
87.7
57.2
73.0
88.8
91.0
91.2
62.5
79.5
96.6
94.5
94.8
84.9
103.0
96.7
96.9
90.2
109.4
98.9
99.1
38.5
54.2
69.8
78.3
45.5
59.6
73.7
78.2
80.0
52.4
65.0
77.6
78.2
79.9
59.4
70.5
81.6
78.1
79.9
76.7
85.8
81.6
83.5
82.8
90.0
85.1
87.0

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
38.6
30.6
51.9
43.9
35.9
65.2
57.2
49.2
41.2
79.0
68.5
60.5
52.5
42.7
33.5
57.2
48.0
38.8
71.8
62.6
53.3
44.1
84.1
74.9
65.7
56.5
87.7
80.0
70.7
61.5
46.8
36.3
62.6
52.1
41.7
78.4
67.9
57.5
47.1
89.3
81.4
70.9
60.5
91.2
86.8
76.4
66.0
50.8
39.2
67.9
56.3
44.6
85.0
73.3
61.7
50.0
94.5
87.8
76.1
64.5
94.8
93.7
82.1
70.4
72.3
59.8
47.2
90.4
77.9
65.3
52.8
96.7
93.2
80.7
68.1
96.9
96.4
83.9
71.3
76.7
63.3
49.8
95.9
82.4
69.0
55.5
98.9
98.7
85.2
71.8
99.1
99.1
85.7
72.2
105°F
33.2
25.2
46.2
38.2
30.3
59.2
51.2
43.3
35.3
75.8
62.2
54.2
46.2
36.5
27.4
50.6
41.5
32.5
64.7
55.7
46.6
37.6
76.6
67.5
58.5
49.5
78.7
69.7
60.7
51.6
39.7
29.6
54.9
44.8
34.7
70.2
60.1
50.0
39.9
77.4
72.9
62.8
52.7
79.3
75.2
65.1
55.0
43.0
31.8
59.3
48.1
37.0
75.7
64.5
53.3
42.1
78.1
78.2
67.1
55.9
79.9
80.8
69.6
58.4
64.4
52.1
39.8
81.1
69.8
57.5
45.2
81.6
81.7
69.4
57.1
83.5
83.9
71.6
59.3
69.4
56.0
42.6
86.6
75.0
61.6
48.2
85.1
85.1
71.7
58.3
87.0
87.0
73.6
60.2

65
44.4
47.3
52.3
50.1
55.5
52.9
58.8
55.6
58.8
58.3
58.7
38.3
40.4
42.6
42.6
44.9
44.7
47.2
44.8
47.0
44.9
46.8

43

528150-YTG-T-0514
ZH090 (7.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

96.7
86.3
75.9
75.3
94.8
84.6
74.4
73.8
75.0
92.9
82.9
72.9
72.3
73.5
91.0
81.2
71.4
70.8
72.0
86.1
75.7
75.1
76.4
91.0
80.1
79.4
80.7

8.4
8.2
8.0
7.9
8.4
8.2
8.1
7.9
7.9
8.5
8.3
8.1
8.0
8.0
8.5
8.3
8.2
8.0
8.0
8.4
8.2
8.1
8.1
8.4
8.2
8.1
8.1

32.9
51.1
69.4
75.3
42.0
56.0
70.0
73.8
75.0
51.1
60.9
70.7
72.3
73.5
60.2
65.8
71.4
70.8
72.0
71.9
75.7
75.1
76.4
78.0
80.1
79.4
80.7

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
30.3
22.4
89.9
9.0
43.3
35.4
27.5
79.5
8.8
56.2
48.4
40.5
32.6
69.1
8.5
74.0
59.3
51.5
43.6
35.7
72.2
8.4
33.1
24.2
86.1
9.1
47.1
38.2
29.3
76.1
8.8
61.1
52.2
43.3
34.4
66.1
8.6
73.0
64.1
55.2
46.3
37.4
69.3
8.4
73.8
64.9
56.0
47.1
38.2
70.1
8.5
35.9
26.0
82.3
9.1
51.0
41.0
31.1
72.7
8.9
66.0
56.1
46.2
36.2
63.1
8.6
71.9
68.8
58.9
48.9
39.0
66.4
8.5
72.9
69.7
59.8
49.8
39.9
67.1
8.5
38.7
27.8
78.5
9.2
54.8
43.9
32.9
69.3
8.9
70.9
60.0
49.0
38.0
60.1
8.7
70.8
73.5
62.6
51.6
40.6
63.5
8.5
72.0
74.5
63.5
52.5
41.6
64.1
8.6
59.9
47.8
35.7
75.0
9.0
75.5
65.3
53.3
41.2
65.1
8.7
75.1
76.5
64.4
52.3
40.3
68.6
8.6
76.4
77.6
65.5
53.5
41.4
69.3
8.6
64.9
51.7
38.5
80.7
9.0
80.1
70.7
57.5
44.4
70.1
8.8
79.4
79.4
66.2
53.1
39.9
73.6
8.6
80.7
80.7
67.6
54.4
41.2
74.4
8.6

90
27.0
48.1
69.1
72.2
38.7
52.4
66.1
69.3
70.1
50.5
56.8
63.1
66.4
67.1
62.2
61.2
60.1
63.5
64.1
67.2
65.1
68.6
69.3
73.2
70.1
73.6
74.4

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
24.2
19.6
40.3
32.5
24.8
53.3
45.5
37.8
30.0
72.2
56.5
48.7
40.9
29.7
20.9
43.7
34.9
26.1
57.6
48.8
40.1
31.3
69.3
60.6
51.8
43.1
68.9
60.1
51.3
42.6
35.2
22.3
47.0
37.2
27.5
61.9
52.1
42.4
32.6
66.4
64.7
54.9
45.2
66.5
64.2
54.4
44.6
40.6
23.7
50.4
39.6
28.8
60.1
55.5
44.7
33.9
63.5
63.5
58.1
47.3
64.1
64.1
57.5
46.7
55.3
43.5
31.7
65.1
60.9
49.1
37.2
68.6
68.6
59.4
47.5
69.3
69.3
59.5
47.6
60.3
47.4
34.5
70.1
66.3
53.4
40.5
73.6
73.6
60.7
47.8
74.4
74.4
61.5
48.6

65
33.2
34.3
33.8
35.4
34.8
36.5
35.9
35.7
35.8
34.9
35.7

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

44

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH102 (8.5 Ton)
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

2125

2550

2975

3400

3825

4250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

136.4
127.5
118.6
103.1
142.1
132.8
123.4
107.3
103.7
147.8
138.0
128.1
111.6
107.8
153.6
143.2
132.9
115.8
111.9
145.4
135.0
117.5
113.5
147.6
137.0
119.3
115.2

6.4
6.3
6.3
6.3
6.4
6.3
6.3
6.4
6.3
6.4
6.4
6.3
6.4
6.3
6.4
6.4
6.3
6.4
6.3
6.4
6.3
6.4
6.3
6.4
6.3
6.4
6.3

58.7
74.7
90.7
103.1
65.3
82.7
100.2
107.3
103.7
71.8
90.7
109.6
111.6
107.8
78.4
98.7
119.0
115.8
111.9
105.1
128.0
117.5
113.5
111.5
137.0
119.3
115.2

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

133.1
118.2
103.3
95.6
134.7
119.6
104.5
96.7
93.6
136.3
121.0
105.8
97.8
94.7
137.9
122.4
107.0
99.0
95.8
125.8
109.9
101.7
98.4
129.2
112.9
104.4
101.0

7.7
7.6
7.6
7.4
7.7
7.7
7.6
7.5
7.5
7.8
7.7
7.7
7.5
7.6
7.8
7.8
7.7
7.6
7.6
7.8
7.7
7.6
7.6
7.8
7.8
7.6
7.7

56.1
69.6
83.1
95.6
61.8
76.3
90.8
96.7
93.6
67.5
83.0
98.5
97.8
94.7
73.2
89.7
106.2
99.0
95.8
96.9
109.5
101.7
98.4
104.1
112.9
104.4
101.0

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
49.1
39.5
134.8
7.0
65.1
55.5
45.9
122.9
7.0
81.1
71.5
61.9
52.3
111.0
6.9
94.8
83.2
73.6
64.0
54.4
99.3
6.9
54.2
43.1
138.4
7.1
71.6
60.6
49.5
126.2
7.0
89.1
78.0
66.9
55.8
114.0
6.9
101.8 90.7
79.6
68.6
57.5
102.0
6.9
103.7 95.2
84.1
73.1
62.0
98.6
6.9
59.3
46.7
142.1
7.1
78.1
65.6
53.0
129.5
7.0
97.0
84.5
71.9
59.4
117.0
7.0
108.8 98.3
85.7
73.2
60.6
104.7
7.0
107.8 103.1 90.6
78.0
65.5
101.2
6.9
64.3
50.3
145.7
7.1
84.7
70.6
56.6
132.8
7.1
105.0 91.0
76.9
62.9
120.0
7.0
115.8 105.8 91.8
77.7
63.7
107.4
7.0
111.9 111.0 97.0
83.0
68.9
103.8
7.0
89.8
74.5
59.1
135.6
7.1
111.2 95.9
80.6
65.3
122.5
7.0
117.5 112.6 97.2
81.9
66.6
109.6
7.0
113.5 113.1 97.8
82.5
67.2
106.0
7.0
94.9
78.3
61.7
138.4
7.1
117.5 100.9 84.2
67.6
124.9
7.0
119.3 119.3 102.7 86.1
69.5
111.8
7.0
115.2 115.2 98.6
82.0
65.4
108.1
7.0
95°F
46.7
37.3
116.2
8.5
60.2
50.8
41.4
104.5
8.3
73.7
64.3
54.9
45.5
92.7
8.2
91.1
77.1
67.7
58.3
48.9
84.7
8.0
50.9
40.0
118.6
8.5
65.4
54.5
43.6
106.6
8.4
79.9
69.0
58.1
47.2
94.6
8.2
93.7
82.8
71.9
61.0
50.1
86.5
8.1
93.6
84.4
73.5
62.6
51.7
84.8
8.1
55.1
42.7
121.0
8.6
70.6
58.2
45.8
108.8
8.4
86.1
73.7
61.3
48.9
96.5
8.3
96.3
88.5
76.1
63.7
51.3
88.3
8.1
94.7
90.2
77.8
65.4
53.0
86.5
8.2
59.4
45.5
123.4
8.6
75.8
62.0
48.1
110.9
8.5
92.3
78.4
64.5
50.7
98.5
8.3
99.0
94.1
80.2
66.4
52.5
90.0
8.2
95.8
95.9
82.1
68.2
54.3
88.3
8.2
81.7
66.6
51.4
112.9
8.5
99.4
84.2
69.1
53.9
100.2
8.4
101.7 99.3
84.1
68.9
53.7
91.6
8.2
98.4
98.5
83.3
68.1
52.9
89.8
8.3
87.6
71.2
54.7
114.8
8.6
106.6 90.1
73.6
57.1
101.9
8.4
104.4 104.4 87.9
71.4
54.9
93.1
8.3
101.0 101.0 84.5
68.0
51.5
91.3
8.3

90
57.4
72.2
86.9
99.3
63.5
79.5
95.5
102.0
98.6
69.7
86.9
104.0
104.7
101.2
75.8
94.2
112.6
107.4
103.8
101.0
118.8
109.6
106.0
107.8
124.9
111.8
108.1
48.4
63.9
79.5
84.7
56.1
70.9
85.7
86.5
84.8
63.9
77.9
91.9
88.3
86.5
71.6
84.8
98.1
90.0
88.3
91.2
100.0
91.6
89.8
97.6
101.9
93.1
91.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
47.9
38.4
62.7
53.1
43.6
77.4
67.9
58.4
48.9
92.9
80.2
70.6
61.1
52.6
41.6
68.5
57.5
46.5
84.5
73.5
62.5
51.5
97.8
86.8
75.8
64.8
98.6
89.8
78.8
67.8
57.2
44.7
74.4
61.9
49.4
91.6
79.1
66.6
54.1
102.6 93.4
80.9
68.4
101.2 96.7
84.2
71.7
61.8
47.9
80.2
66.3
52.3
98.6
84.7
70.7
56.8
107.4 100.0 86.0
72.0
103.8 103.5 89.5
75.6
85.8
70.5
55.2
105.3 90.1
74.8
59.6
109.6 105.9 90.7
75.4
106.0 105.8 90.6
75.3
91.3
74.7
58.2
112.0 95.5
78.9
62.4
111.8 111.8 95.3
78.7
108.1 108.1 91.6
75.0
105°F
41.1
31.9
54.7
45.5
36.2
68.3
59.0
49.8
40.5
82.5
69.4
60.1
50.9
45.3
34.6
60.1
49.3
38.5
74.9
64.1
53.3
42.5
85.0
75.3
64.5
53.7
84.8
76.0
65.2
54.4
49.6
37.3
65.5
53.2
40.9
81.5
69.2
56.8
44.5
87.5
81.2
68.9
56.5
86.5
82.0
69.6
57.3
53.8
39.9
71.0
57.1
43.2
88.1
74.2
60.3
46.5
90.0
87.1
73.2
59.4
88.3
87.9
74.1
60.2
76.2
61.1
46.1
93.4
79.5
64.4
49.4
91.6
90.1
75.1
60.0
89.8
89.6
74.6
59.5
81.4
65.2
49.0
98.7
84.7
68.5
52.3
93.1
93.1
76.9
60.7
91.3
91.3
75.1
58.9

65
51.6
53.8
56.8
55.9
59.2
58.1
61.6
60.1
60.0
62.2
58.5
41.6
42.9
43.6
44.2
45.0
45.5
46.3
45.0
44.5
44.5
42.7

45

528150-YTG-T-0514
ZH102 (8.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

99.3
90.7
82.0
73.9
102.5
93.6
84.7
76.3
76.1
105.7
96.5
87.3
78.7
78.4
108.9
99.4
90.0
81.1
80.8
99.9
90.4
81.5
81.2
100.4
90.8
81.9
81.6

9.3
9.0
8.8
8.6
9.4
9.1
8.8
8.7
8.7
9.4
9.1
8.9
8.7
8.8
9.5
9.2
8.9
8.8
8.8
9.3
9.0
8.9
8.9
9.4
9.1
9.0
9.0

40.7
58.3
75.8
73.9
50.5
65.5
80.5
76.3
76.1
60.2
72.7
85.3
78.7
78.4
69.9
79.9
90.0
81.1
80.8
85.5
90.4
81.5
81.2
91.0
90.8
81.9
81.6

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
35.5
26.4
82.4
10.1
49.2
40.1
31.0
76.9
9.7
62.9
53.8
44.7
35.6
71.4
9.4
73.9
61.6
52.5
43.4
34.3
63.1
9.2
39.8
29.1
86.4
10.2
54.8
44.1
33.5
80.6
9.8
69.9
59.2
48.5
37.8
74.8
9.4
76.3
67.7
57.1
46.4
35.7
66.1
9.3
76.1
67.6
56.9
46.2
35.6
67.3
9.3
44.0
31.8
90.4
10.2
60.5
48.2
35.9
84.3
9.8
76.9
64.6
52.3
40.0
78.1
9.5
78.7
73.9
61.7
49.4
37.1
69.1
9.3
78.4
73.8
61.5
49.2
36.9
70.3
9.4
48.3
34.4
94.4
10.3
66.1
52.2
38.3
87.9
9.9
83.9
70.0
56.1
42.3
81.5
9.5
81.1
80.1
66.2
52.4
38.5
72.1
9.4
80.8
79.9
66.0
52.2
38.3
73.3
9.4
70.6
55.7
40.8
87.0
10.0
87.4
74.7
59.8
44.9
80.6
9.6
81.5
81.0
66.1
51.2
36.3
71.4
9.5
81.2
80.8
65.9
51.0
36.1
72.6
9.6
75.1
59.2
43.3
86.0
10.1
90.8
79.4
63.5
47.6
79.8
9.8
81.9
81.9
66.0
50.1
34.2
70.6
9.6
81.6
81.6
65.7
49.8
33.9
71.9
9.7

90
33.8
52.6
71.4
63.1
45.4
60.1
74.8
66.1
67.3
57.1
67.6
78.1
69.1
70.3
68.7
75.1
81.5
72.1
73.3
79.8
80.6
71.4
72.6
84.5
79.8
70.6
71.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
29.9
21.0
43.7
34.8
25.9
57.5
48.5
39.6
30.7
63.1
53.8
44.9
35.9
34.2
23.7
49.5
39.0
28.4
64.9
54.3
43.7
33.2
66.1
60.2
49.7
39.1
67.3
59.2
48.6
38.0
38.5
26.3
55.4
43.2
30.9
72.3
60.0
47.8
35.6
69.1
66.7
54.4
42.2
70.3
65.5
53.3
41.1
42.8
28.9
61.2
47.3
33.5
79.6
65.8
51.9
38.1
72.1
72.1
59.2
45.4
73.3
71.9
58.0
44.2
65.0
50.3
35.6
80.6
69.9
55.2
40.5
71.4
71.4
57.1
42.4
72.6
71.9
57.2
42.4
68.9
53.3
37.6
79.8
74.1
58.5
42.9
70.6
70.6
55.0
39.4
71.9
71.9
56.3
40.7

65
27.0
28.5
27.5
30.0
28.9
31.5
30.3
27.6
27.7
23.8
25.1

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

46

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH120 (10 Ton)
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

2500

3000

3500

4000

4500

5000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

148.4
138.6
128.8
119.6
155.1
144.8
134.6
124.9
122.1
161.8
151.1
140.3
130.3
127.3
168.5
157.3
146.1
135.7
132.6
157.8
146.6
136.1
133.0
158.3
147.1
136.6
133.4

7.2
7.0
6.7
6.7
7.2
7.0
6.7
6.7
6.7
7.2
6.9
6.7
6.7
6.7
7.2
6.9
6.7
6.6
6.6
7.0
6.8
6.8
6.8
7.2
6.9
6.9
6.9

37.9
56.2
74.4
103.4
54.6
74.7
94.8
114.1
116.9
71.2
93.2
115.1
124.9
124.7
87.9
111.7
135.4
135.7
132.6
102.0
126.3
136.1
133.0
92.4
117.2
136.6
133.4

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

142.1
129.8
117.5
110.7
146.4
133.7
121.1
114.0
111.4
150.6
137.6
124.6
117.3
114.6
154.9
141.5
128.1
120.7
117.9
142.7
129.1
121.6
118.8
143.8
130.2
122.6
119.8

8.5
8.5
8.5
8.4
8.5
8.5
8.6
8.5
8.5
8.5
8.6
8.6
8.5
8.5
8.6
8.6
8.6
8.5
8.5
8.6
8.6
8.5
8.5
8.6
8.6
8.5
8.5

32.5
50.0
67.4
97.7
49.2
68.3
87.5
105.4
105.8
65.8
86.7
107.6
113.0
111.9
82.5
105.1
127.6
120.7
117.9
95.3
118.5
121.6
118.8
85.5
109.4
122.6
119.8

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
39.0
40.1
145.3
7.9
57.2
58.3
59.4
134.2
7.7
75.5
76.5
77.6
78.7
123.2
7.6
95.5
94.1
95.2
96.2
97.3
115.1
7.6
49.4
44.1
150.7
7.9
69.4
64.2
59.0
139.3
7.8
89.5
84.3
79.0
73.8
127.8
7.6
108.9 103.6 98.4
93.2
87.9
119.5
7.6
111.7 106.4 101.2 95.9
90.7
116.7
7.6
59.7
48.2
156.2
7.9
81.6
70.1
58.6
144.3
7.8
103.6 92.0
80.5
68.9
132.5
7.6
122.3 113.2 101.6 90.1
78.6
123.8
7.6
122.1 116.2 104.7 93.1
81.6
121.0
7.6
70.1
52.2
161.7
7.9
93.8
76.0
58.2
149.4
7.8
117.6 99.8
81.9
64.1
137.1
7.7
135.7 122.7 104.9 87.0
69.2
128.2
7.6
132.6 126.0 108.1 90.3
72.5
125.2
7.6
89.8
77.6
65.4
150.2
7.8
114.1 101.9 89.7
77.5
137.9
7.7
136.1 125.3 113.1 100.9 88.7
128.9
7.6
133.0 128.9 116.7 104.5 92.3
125.9
7.6
85.8
79.3
72.7
151.1
7.9
110.6 104.1 97.5
91.0
138.6
7.8
136.6 128.0 121.4 114.9 108.3
129.6
7.7
133.4 131.8 125.2 118.6 112.1
126.6
7.7
95°F
34.3
36.0
130.2
9.7
51.7
53.4
55.2
120.3
9.7
69.2
70.9
72.6
74.4
110.4
9.7
90.5
87.2
88.9
90.7
92.4
104.5
9.6
44.3
39.5
133.8
9.8
63.5
58.7
53.8
123.6
9.7
82.7
77.8
73.0
68.1
113.4
9.7
100.5 95.7
90.8
86.0
81.2
107.3
9.6
101.0 96.2
91.3
86.5
81.6
104.7
9.6
54.4
43.0
137.3
9.8
75.3
63.9
52.4
126.9
9.8
96.1
84.7
73.3
61.9
116.5
9.7
110.6 104.2 92.8
81.3
69.9
110.2
9.7
109.4 104.7 93.3
81.9
70.4
107.4
9.6
64.5
46.5
140.9
9.8
87.1
69.1
51.1
130.2
9.8
109.6 91.6
73.6
55.6
119.5
9.8
120.7 112.7 94.7
76.7
58.7
113.0
9.7
117.9 113.2 95.2
77.2
59.2
110.2
9.6
83.2
71.2
59.1
131.2
9.8
106.5 94.4
82.3
70.3
120.4
9.8
121.6 116.1 104.0 92.0
79.9
113.9
9.7
118.8 116.5 104.5 92.4
80.3
111.0
9.6
79.4
73.3
67.1
132.2
9.8
103.3 97.2
91.1
84.9
121.3
9.8
122.6 119.5 113.4 107.3 101.1
114.8
9.7
119.8 119.8 113.7 107.5 101.4
111.9
9.6

90
35.2
53.1
70.9
100.5
51.9
71.5
91.1
109.7
111.4
68.5
89.9
111.3
118.9
118.3
85.2
108.4
131.5
128.2
125.2
98.7
122.4
128.9
125.9
89.0
113.3
129.6
126.6
26.3
46.3
66.3
92.5
45.2
64.6
84.0
99.4
99.7
64.0
82.8
101.6
106.2
105.0
82.8
101.0
119.2
113.0
110.2
91.1
112.4
113.9
111.0
81.2
105.5
114.8
111.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
36.6
38.0
54.5
55.9
57.3
72.3
73.7
75.1
76.5
93.0
90.7
92.1
93.5
46.8
41.8
66.5
61.4
56.4
86.1
81.0
76.0
71.0
104.7 99.7
94.6
89.6
106.3 101.3 96.3
91.2
57.1
45.6
78.5
67.0
55.5
99.8
88.4
76.9
65.4
116.4 108.7 97.2
85.7
115.8 110.4 99.0
87.5
67.3
49.4
90.4
72.5
54.6
113.6 95.7
77.8
59.9
128.2 117.7 99.8
81.8
125.2 119.6 101.7 83.8
86.5
74.4
62.3
110.3 98.2
86.0
73.9
128.9 120.7 108.6 96.5
125.9 122.7 110.6 98.4
82.6
76.3
69.9
107.0 100.6 94.3
87.9
129.6 123.8 117.4 111.1
126.6 125.8 119.4 113.1
105°F
30.7
32.7
48.4
50.4
52.5
66.1
68.2
70.2
72.3
85.6
82.2
84.3
86.3
40.5
35.9
59.9
55.3
50.6
79.3
74.7
70.0
65.4
94.7
90.1
85.4
80.8
95.1
90.4
85.8
81.1
50.3
39.0
71.4
60.1
48.7
92.5
81.2
69.8
58.5
103.9 97.9
86.6
75.2
102.6 98.3
87.0
75.6
60.2
42.1
83.0
64.9
46.8
105.7 87.7
69.6
51.6
113.0 105.8 87.7
69.7
110.2 106.2 88.1
70.1
79.1
67.1
55.1
102.7 90.7
78.7
66.7
113.9 109.4 97.4
85.4
111.0 109.0 97.1
85.1
75.3
69.4
63.4
99.6
93.7
87.8
81.9
114.8 113.0 107.1 101.2
111.9 111.9 106.0 100.1

65
94.9
84.5
86.2
74.2
76.0
63.9
65.8
84.3
86.3
104.7
106.7
88.4
76.1
76.5
63.9
64.3
51.6
52.0
73.5
73.1
95.3
94.2

47

528150-YTG-T-0514
ZH120 (10 Ton) (Continued)
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

118.3
110.8
103.3
98.3
121.2
113.5
105.8
100.7
97.9
124.0
116.2
108.3
103.0
100.2
126.9
118.9
110.8
105.4
102.5
119.7
111.6
106.2
103.3
120.5
112.4
106.9
104.0

11.0
10.9
10.9
10.8
11.0
10.9
10.9
10.8
10.7
11.0
10.9
10.9
10.8
10.7
11.0
11.0
10.9
10.8
10.7
10.9
10.9
10.8
10.7
10.9
10.9
10.8
10.7

20.1
42.7
65.2
87.3
41.1
60.8
80.4
93.4
93.6
62.1
78.9
95.6
99.4
98.1
83.1
97.0
110.8
105.4
102.5
86.9
106.2
106.2
103.3
76.8
101.6
106.9
104.0

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
27.1
29.5
106.4
12.3
45.0
47.4
49.8
101.3
12.2
63.0
65.4
67.8
70.2
96.2
12.0
80.7
77.2
79.6
82.0
84.4
92.1
12.0
36.7
32.2
108.6
12.3
56.3
51.9
47.4
103.4
12.1
76.0
71.5
67.1
62.6
98.2
12.0
88.9
84.5
80.0
75.6
71.1
94.0
12.0
89.1
84.7
80.2
75.8
71.3
91.2
11.8
46.3
35.0
110.7
12.3
67.6
56.3
45.0
105.5
12.1
88.9
77.6
66.3
55.0
100.2
12.0
97.2
91.7
80.4
69.1
57.8
95.9
12.0
95.8
91.9
80.6
69.4
58.1
93.0
11.8
55.8
37.7
112.9
12.3
78.8
60.7
42.6
107.5
12.1
101.8 83.7
65.6
47.5
102.2
12.0
105.4 98.9
80.8
62.6
44.5
97.8
12.0
102.5 99.2
81.0
62.9
44.8
94.9
11.8
75.0
63.1
51.2
108.2
12.1
98.9
87.0
75.1
63.2
102.8
12.0
106.2 102.7 90.8
78.9
67.0
98.4
12.0
103.3 101.6 89.7
77.8
65.9
95.5
11.8
71.1
65.5
59.8
108.9
12.1
95.9
90.2
84.6
78.9
103.5
12.0
106.9 106.6 100.9 95.2
89.5
99.0
12.0
104.0 104.0 98.3
92.6
86.9
96.1
11.8

90
13.8
39.0
64.1
82.1
37.1
57.0
76.9
87.3
87.5
60.4
75.0
89.7
92.6
91.2
83.6
92.9
102.2
97.8
94.9
82.7
100.1
98.4
95.5
72.5
97.7
99.0
96.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
23.5
26.2
41.7
44.4
47.1
59.9
62.6
65.4
68.1
75.7
72.3
75.0
77.7
32.8
28.6
52.7
48.5
44.2
72.6
68.4
64.1
59.8
83.1
78.8
74.6
70.3
83.2
79.0
74.7
70.4
42.2
31.0
63.7
52.5
41.3
85.3
74.1
62.8
51.6
90.4
85.4
74.2
63.0
89.1
85.5
74.3
63.1
51.5
33.3
74.7
56.6
38.4
98.0
79.8
61.6
43.4
97.8
92.0
73.8
55.6
94.9
92.1
73.9
55.8
70.9
59.1
47.2
95.1
83.3
71.4
59.6
98.4
96.0
84.2
72.4
95.5
94.1
82.3
70.5
67.0
61.5
56.1
92.2
86.8
81.3
75.8
99.0
99.0
94.6
89.2
96.1
96.1
90.6
85.2

65
80.4
66.1
66.2
51.8
51.9
37.4
37.6
60.6
58.6
83.7
79.7

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

48

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH150 (12.5 Ton)
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

3125

3750

4375

5000

5625

6250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

204.4
186.6
168.8
153.0
210.2
191.8
173.5
157.2
152.9
215.9
197.1
178.3
161.5
157.1
221.6
202.3
183.0
165.8
161.2
206.6
186.9
169.3
164.7
210.9
190.8
172.9
168.1

9.6
9.3
9.1
9.0
9.7
9.4
9.1
9.0
8.9
9.7
9.4
9.2
9.1
9.0
9.8
9.5
9.2
9.1
9.0
9.5
9.2
9.2
9.0
9.5
9.3
9.2
9.0

82.4
106.6
130.7
153.0
89.0
114.7
140.4
157.2
152.9
95.5
122.8
150.1
161.5
157.1
102.1
130.9
159.8
165.8
161.2
140.7
174.9
169.3
164.7
150.5
190.0
172.9
168.1

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

180.0
165.5
151.0
136.9
184.8
169.9
155.0
140.5
141.0
189.6
174.3
159.0
144.2
144.6
194.4
178.7
163.0
147.8
148.3
180.4
164.5
149.2
149.7
182.1
166.1
150.6
151.1

11.6
11.4
11.3
11.0
11.7
11.5
11.4
11.1
11.0
11.8
11.6
11.5
11.2
11.1
11.9
11.7
11.6
11.3
11.2
11.7
11.6
11.3
11.2
11.8
11.6
11.3
11.3

71.9
94.9
117.8
136.9
79.6
104.6
129.6
140.5
141.0
87.3
114.3
141.4
144.2
144.6
94.9
124.1
153.2
147.8
148.3
131.9
159.6
149.2
149.7
139.7
166.1
150.6
151.1

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
68.5
54.6
192.2
10.6
92.6
78.7
64.8
176.1
10.4
116.8 102.9 88.9
75.0
159.9
10.2
143.5 127.2 113.3 99.4
85.5
144.9
10.0
73.6
58.1
197.5
10.7
99.3
83.9
68.4
180.9
10.5
125.0 109.6 94.2
78.7
164.3
10.2
150.9 135.5 120.1 104.7 89.3
148.9
10.1
152.9 144.1 128.7 113.3 97.8
146.9
10.0
78.6
61.7
202.8
10.8
105.9 89.0
72.1
185.7
10.5
133.2 116.3 99.4
82.5
168.6
10.3
158.4 143.8 126.9 110.0 93.1
152.8
10.1
157.1 152.9 136.0 119.1 102.2
150.8
10.1
83.7
65.3
208.0
10.8
112.6 94.2
75.8
190.5
10.6
141.4 123.0 104.6 86.2
173.0
10.4
165.8 152.1 133.7 115.3 96.9
156.8
10.2
161.2 161.8 143.4 125.0 106.6
154.8
10.1
121.0 101.3 81.6
193.5
10.6
152.0 132.3 112.6 92.9
175.7
10.4
169.3 162.5 142.8 123.1 103.4
159.3
10.2
164.7 165.0 145.3 125.6 105.8
157.2
10.1
129.4 108.4 87.4
196.5
10.6
162.7 141.6 120.6 99.6
178.4
10.4
172.9 172.9 151.8 130.8 109.8
161.7
10.2
168.1 168.1 147.1 126.1 105.0
159.6
10.2
95°F
58.7
45.5
169.2
13.1
81.7
68.5
55.2
155.1
13.0
104.6 91.4
78.2
65.0
140.9
12.8
133.3 113.0 99.8
86.6
73.4
128.7
12.5
64.6
49.6
173.5
13.2
89.6
74.6
59.6
159.0
13.0
114.6 99.6
84.6
69.6
144.5
12.8
138.1 123.1 108.1 93.1
78.1
131.9
12.6
141.0 126.3 111.3 96.3
81.3
131.4
12.6
70.5
53.7
177.8
13.2
97.5
80.7
63.9
162.9
13.1
124.6 107.8 91.0
74.2
148.1
12.9
143.0 133.3 116.5 99.7
82.9
135.2
12.6
144.6 136.7 119.9 103.1 86.3
134.6
12.6
76.3
57.7
182.0
13.3
105.5 86.9
68.3
166.8
13.1
134.6 116.0 97.4
78.8
151.6
12.9
147.8 143.4 124.8 106.2 87.6
138.4
12.7
148.3 147.1 128.5 109.9 91.3
137.8
12.7
112.0 92.2
72.3
168.0
13.2
142.9 123.1 103.2 83.3
152.7
13.0
149.2 147.0 127.1 107.3 87.4
139.4
12.7
149.7 149.1 129.2 109.4 89.5
138.8
12.7
118.6 97.4
76.3
169.2
13.2
151.3 130.1 109.0 87.9
153.7
13.0
150.6 150.6 129.5 108.3 87.2
140.4
12.7
151.1 151.1 130.0 108.8 87.7
139.8
12.7

90
77.2
100.7
124.3
144.9
84.3
109.7
135.0
148.9
146.9
91.4
118.6
145.8
152.8
150.8
98.5
127.5
156.5
156.8
154.8
136.3
167.3
159.3
157.2
145.1
178.0
161.7
159.6
68.8
91.6
114.3
128.7
76.3
100.7
125.1
131.9
131.4
83.9
109.9
135.9
135.2
134.6
91.5
119.1
146.7
138.4
137.8
127.6
150.2
139.4
138.8
136.0
153.7
140.4
139.8

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
63.6
50.0
87.2
73.6
60.0
110.7 97.1
83.6
70.0
138.4 120.1 106.6 93.0
69.1
53.9
94.4
79.2
64.0
119.8 104.6 89.4
74.2
144.5 129.3 114.1 98.9
146.9 135.2 120.0 104.8
74.5
57.7
101.7 84.9
68.0
128.9 112.0 95.2
78.3
150.7 138.5 121.7 104.8
150.8 144.8 128.0 111.1
80.0
61.5
109.0 90.5
72.0
138.0 119.5 101.0 82.5
156.8 147.8 129.3 110.8
154.8 154.5 136.0 117.5
116.5 96.7
76.9
147.5 127.7 107.9 88.1
159.3 154.7 135.0 115.2
157.2 157.0 137.2 117.5
124.0 102.9 81.8
157.0 135.9 114.8 93.7
161.7 161.7 140.6 119.6
159.6 159.6 138.5 117.4
105°F
56.1
43.0
78.5
65.5
52.4
100.9 87.9
74.9
61.8
126.9 108.9 95.8
82.8
61.6
46.8
86.0
71.2
56.5
110.4 95.6
80.9
66.1
130.7 118.4 103.7 88.9
131.4 118.3 103.5 88.8
67.1
50.6
93.4
77.0
60.5
119.8 103.3 86.9
70.4
134.6 128.0 111.5 95.0
134.6 127.8 111.4 94.9
72.6
54.4
100.9 82.7
64.5
129.2 111.0 92.9
74.7
138.4 137.5 119.3 101.1
137.8 137.4 119.2 101.0
107.9 88.2
68.6
137.8 118.5 98.8
79.1
139.4 138.9 119.3 99.6
138.8 138.6 118.9 99.3
114.9 93.8
72.6
146.3 125.9 104.8 83.6
140.4 140.4 119.2 98.1
139.8 139.8 118.6 97.5

65
79.4
83.7
89.6
88.0
94.3
92.3
99.0
95.4
97.7
98.5
96.4
69.8
74.1
74.0
78.5
78.4
82.9
82.8
80.0
79.6
77.0
76.4

49

528150-YTG-T-0514
ZH150 (12.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

158.4
144.6
130.9
120.5
162.2
148.1
134.0
123.3
121.8
165.9
151.5
137.1
126.2
124.6
169.7
155.0
140.2
129.1
127.4
155.6
140.8
129.6
127.9
156.2
141.4
130.1
128.4

14.6
14.5
14.3
14.0
14.7
14.5
14.3
14.1
14.1
14.7
14.5
14.3
14.1
14.1
14.7
14.5
14.3
14.1
14.2
14.6
14.4
14.1
14.2
14.6
14.4
14.2
14.2

65.6
88.2
110.9
120.5
73.1
96.9
120.6
123.3
121.8
80.6
105.5
130.4
126.2
124.6
88.1
114.2
140.2
129.1
127.4
123.2
140.8
129.6
127.9
132.3
141.4
130.1
128.4

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
53.5
40.6
147.6
16.1
75.4
62.5
49.6
134.2
16.0
97.3
84.4
71.5
58.7
120.9
15.8
120.5 104.7 91.9
79.0
66.1
112.3
15.6
58.6
44.1
150.8
16.1
82.4
67.9
53.3
137.2
16.0
106.1 91.6
77.1
62.6
123.5
15.8
123.3 113.7 99.2
84.7
70.2
114.8
15.6
121.8 110.3 95.8
81.2
66.7
112.1
15.6
63.7
47.6
154.1
16.1
89.4
73.2
57.1
140.1
15.9
115.0 98.9
82.7
66.6
126.2
15.8
126.2 122.7 106.5 90.4
74.2
117.2
15.5
124.6 119.0 102.8 86.7
70.5
114.6
15.6
68.8
51.0
157.3
16.1
96.4
78.6
60.8
143.1
15.9
123.9 106.1 88.3
70.5
128.9
15.7
129.1 131.7 113.9 96.1
78.3
119.7
15.5
127.4 127.7 109.9 92.1
74.3
117.0
15.6
103.8 84.3
64.9
143.2
16.0
132.6 113.9 94.4
74.9
128.9
15.8
129.6 130.9 111.4 92.0
72.5
119.8
15.6
127.9 128.1 108.6 89.1
69.7
117.0
15.6
111.2 90.1
69.0
143.3
16.0
141.4 121.6 100.5 79.4
129.0
15.8
130.1 130.1 109.0 87.9
66.8
119.9
15.6
128.4 128.4 107.3 86.2
65.1
117.1
15.7

90
60.0
84.9
107.4
112.3
69.9
93.0
116.2
114.8
112.1
79.7
101.1
125.0
117.2
114.6
89.6
109.2
128.9
119.7
117.0
118.9
128.9
119.8
117.0
128.6
129.0
119.9
117.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
50.8
38.1
72.2
59.5
46.8
93.6
80.9
68.2
55.5
112.3 100.7 87.9
75.2
55.6
41.3
78.7
64.5
50.2
101.9 87.6
73.4
59.1
114.8 109.0 94.7
80.5
112.1 102.2 88.0
73.7
60.3
44.5
85.3
69.5
53.6
110.2 94.4
78.6
62.7
117.2 117.2 101.6 85.7
114.6 110.1 94.3
78.4
65.1
47.7
91.8
74.4
57.0
118.6 101.1 83.7
66.3
119.7 119.7 108.4 91.0
117.0 117.0 100.6 83.2
99.7
80.4
61.2
127.5 109.3 90.0
70.8
119.8 119.8 103.6 84.3
117.0 117.0 98.3
79.0
107.5 86.4
65.3
129.0 117.4 96.3
75.2
119.9 119.9 98.8
77.7
117.1 117.1 96.0
74.9

65
62.5
66.2
59.4
69.9
62.6
73.6
65.7
65.1
59.8
56.5
53.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

50

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ037-150 Cooling Capacities
ZJ037 (3.0 Ton)
Air on
Evaporator Coil
CFM

750

900

1050

1200

1350

1500

750

900

1050

1200

1350

1500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

49.2
43.8
38.4
33.2
51.6
45.9
40.3
34.8
29.4
54.0
48.1
42.2
36.4
30.8
56.4
50.2
44.1
38.1
32.2
51.5
45.1
39.0
33.0
52.7
46.2
39.9
33.8

2.1
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

19.7
24.5
29.4
33.2
22.2
27.6
33.0
34.8
29.4
24.8
30.7
36.6
36.4
30.8
27.4
33.8
40.2
38.1
32.2
36.7
43.2
39.0
33.0
39.6
46.2
39.9
33.8

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

41.1
36.5
31.9
27.6
43.3
38.5
33.6
29.0
28.3
45.4
40.4
35.3
30.5
29.7
47.6
42.3
37.0
32.0
31.2
43.0
37.6
32.4
31.6
43.6
38.1
32.9
32.1

2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.4
2.6
2.5
2.5
2.4
2.4
2.6
2.5
2.5
2.4
2.4
2.5
2.5
2.4
2.4
2.5
2.5
2.4
2.4

16.4
21.0
25.6
27.6
18.9
24.1
29.3
29.0
28.3
21.4
27.2
32.9
30.5
29.7
23.9
30.2
36.6
32.0
31.2
32.8
37.4
32.4
31.6
35.4
38.1
32.9
32.1

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
16.4
13.1
45.1
2.3
21.2
17.9
14.6
40.2
2.3
26.1
22.8
19.5
16.2
35.2
2.2
33.2
27.2
23.9
20.6
17.3
30.4
2.2
18.3
14.5
47.4
2.3
23.7
19.8
15.9
42.2
2.3
29.1
25.2
21.3
17.4
37.0
2.2
34.8
30.1
26.2
22.3
18.4
31.9
2.2
29.4
31.7
27.8
23.9
20.0
28.9
2.2
20.3
15.8
49.7
2.3
26.2
21.7
17.3
44.2
2.3
32.1
27.6
23.2
18.7
38.7
2.2
36.4
33.0
28.5
24.0
19.5
33.5
2.2
30.8
38.9
32.1
29.9
25.4
30.3
2.2
22.3
17.2
52.0
2.3
28.7
23.7
18.6
46.3
2.3
35.2
30.1
25.0
19.9
40.5
2.2
38.1
35.9
30.8
25.7
20.6
35.0
2.2
32.2
46.0
36.4
35.8
30.7
31.7
2.2
31.0
25.4
19.7
47.2
2.3
37.9
32.3
26.6
20.9
41.3
2.2
39.0
37.9
32.2
26.6
20.9
35.7
2.2
33.0
39.9
31.9
28.6
22.9
32.3
2.2
33.3
27.1
20.9
48.1
2.3
40.7
34.4
28.2
22.0
42.2
2.2
39.9
39.9
33.7
27.4
21.2
36.4
2.2
33.8
33.8
27.5
21.3
15.0
32.9
2.2
95°F
13.3
10.2
36.8
2.8
17.9
14.8
11.7
32.9
2.7
22.5
19.4
16.3
13.2
28.9
2.7
27.6
23.3
20.2
17.1
14.0
24.9
2.6
15.2
11.5
38.6
2.8
20.4
16.7
13.0
34.5
2.7
25.6
21.9
18.1
14.4
30.3
2.7
29.0
26.2
22.5
18.8
15.1
26.1
2.6
28.3
26.0
22.3
18.6
14.9
25.5
2.6
17.1
12.7
40.4
2.8
22.8
18.5
14.2
36.1
2.8
28.6
24.3
20.0
15.7
31.7
2.7
30.5
29.1
24.8
20.5
16.2
27.3
2.6
29.7
29.0
24.6
20.3
16.0
26.7
2.6
19.0
14.0
42.2
2.9
25.3
20.4
15.5
37.7
2.8
31.7
26.8
21.8
16.9
33.1
2.7
32.0
32.1
27.2
22.2
17.3
28.5
2.6
31.2
31.9
27.0
22.0
17.1
27.9
2.7
27.4
21.9
16.5
38.2
2.8
34.2
28.7
23.3
17.9
33.6
2.7
32.4
32.5
27.1
21.6
16.2
28.9
2.7
31.6
32.0
26.6
21.1
15.7
28.3
2.7
29.4
23.4
17.5
38.7
2.8
36.7
30.7
24.8
18.8
34.0
2.7
32.9
32.9
27.0
21.0
15.1
29.3
2.7
32.1
32.1
26.2
20.2
14.2
28.7
2.7

90
18.0
22.8
27.5
30.4
20.6
25.9
31.1
31.9
28.9
23.1
28.9
34.8
33.5
30.3
25.6
32.0
38.4
35.0
31.7
34.8
40.3
35.7
32.3
37.5
42.2
36.4
32.9
13.8
19.3
24.9
24.9
16.9
22.2
27.6
26.1
25.5
20.0
25.1
30.2
27.3
26.7
23.1
28.0
32.9
28.5
27.9
30.5
33.5
28.9
28.3
32.9
34.0
29.3
28.7

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
14.8
11.6
19.6
16.4
13.2
24.3
21.1
17.9
14.7
30.4
25.3
22.0
18.8
16.8
13.0
22.1
18.3
14.4
27.3
23.5
19.7
15.9
31.9
28.2
24.4
20.6
28.9
28.9
25.1
21.3
18.7
14.3
24.5
20.1
15.7
30.4
26.0
21.6
17.2
33.5
31.1
26.7
22.3
30.3
33.9
28.4
25.1
20.6
15.6
27.0
22.0
17.0
33.4
28.4
23.4
18.4
35.0
34.0
29.0
24.0
31.7
38.9
31.7
28.9
29.2
23.6
18.1
36.1
30.5
24.9
19.4
35.7
35.2
29.6
24.1
32.3
35.9
29.3
24.8
31.4
25.3
19.2
38.7
32.6
26.5
20.4
36.4
36.4
30.3
24.2
32.9
32.9
26.8
20.7
105°F
11.6
8.6
16.3
13.3
10.3
21.0
18.0
15.0
12.0
24.9
21.8
18.8
15.8
13.3
9.7
18.6
15.0
11.4
24.0
20.4
16.8
13.2
26.1
24.6
21.0
17.4
25.5
23.6
20.0
16.4
15.0
10.8
20.9
16.8
12.6
26.9
22.7
18.5
14.3
27.3
27.4
23.3
19.1
26.7
26.4
22.2
18.0
16.7
11.9
23.3
18.5
13.7
29.8
25.0
20.3
15.5
28.5
30.3
25.5
20.7
27.9
29.1
24.3
19.5
25.2
19.9
14.6
31.6
27.0
21.7
16.4
28.9
29.8
24.5
19.2
28.3
28.9
23.6
18.3
27.1
21.3
15.5
33.3
28.9
23.0
17.2
29.3
29.3
23.5
17.6
28.7
28.7
22.9
17.0

65
15.6
16.8
17.5
17.9
20.7
19.0
23.9
18.5
19.3
18.1
14.6
12.8
13.8
12.8
14.9
13.8
15.9
14.7
13.9
13.0
11.8
11.2

51

528150-YTG-T-0514
ZJ037 (3.0 Ton) (Continued)
Air on
Evaporator Coil
CFM

750

900

1050

1200

1350

1500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

32.6
29.2
25.9
22.2
34.0
30.5
27.0
23.1
22.8
35.4
31.8
28.1
24.1
23.7
36.8
33.0
29.2
25.0
24.7
33.4
29.6
25.3
24.9
33.8
29.9
25.6
25.2

3.1
3.0
2.9
2.8
3.1
3.0
2.9
2.8
2.8
3.1
3.0
2.9
2.8
2.9
3.1
3.0
2.9
2.8
2.9
3.0
2.9
2.9
2.9
3.1
3.0
2.9
2.9

11.2
17.7
24.2
22.2
14.9
20.4
25.9
23.1
22.8
18.7
23.1
27.5
24.1
23.7
22.4
25.8
29.2
25.0
24.7
28.2
29.6
25.3
24.9
30.5
29.9
25.6
25.2

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
9.9
7.0
28.3
3.3
14.8
11.8
8.9
25.6
3.2
19.6
16.6
13.7
10.8
22.9
3.1
22.2
20.3
17.4
14.4
11.5
19.5
3.0
11.4
7.9
29.4
3.4
16.9
13.4
9.9
26.5
3.2
22.4
18.9
15.4
11.9
23.7
3.1
23.1
23.0
19.5
16.0
12.5
20.2
3.0
22.8
21.2
17.8
14.3
10.8
20.0
3.1
12.9
8.9
30.4
3.4
19.1
15.0
10.9
27.5
3.3
25.2
21.1
17.0
13.0
24.5
3.1
24.1
25.7
21.7
17.6
13.6
20.9
3.0
23.7
23.8
19.7
15.6
11.6
20.7
3.1
14.5
9.8
31.4
3.4
21.2
16.6
12.0
28.4
3.3
28.0
23.3
18.7
14.1
25.4
3.1
25.0
28.5
23.8
19.2
14.6
21.6
3.0
24.7
26.3
21.6
17.0
12.4
21.4
3.1
23.0
17.9
12.7
28.6
3.3
28.9
25.2
20.0
14.9
25.6
3.2
25.3
27.0
21.9
16.7
11.6
21.8
3.1
24.9
25.7
20.6
15.4
10.3
21.6
3.1
24.8
19.2
13.5
28.9
3.3
29.9
27.0
21.3
15.6
25.8
3.2
25.6
25.6
19.9
14.3
8.6
22.0
3.1
25.2
25.2
19.6
13.9
8.2
21.8
3.2

90
9.2
16.0
22.9
19.5
13.4
18.6
23.7
20.2
20.0
17.6
21.1
24.5
20.9
20.7
21.9
23.6
25.4
21.6
21.4
25.9
25.6
21.8
21.6
28.1
25.8
22.0
21.8

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
7.9
5.4
13.2
10.3
7.5
18.1
15.3
12.4
9.6
19.5
19.5
16.0
13.1
9.6
6.2
15.2
11.8
8.4
20.8
17.4
14.0
10.6
20.2
20.2
18.0
14.7
20.0
18.8
15.5
12.1
11.3
7.0
17.2
13.2
9.3
23.4
19.5
15.6
11.7
20.9
20.9
20.1
16.2
20.7
20.7
17.2
13.3
12.9
7.7
19.1
14.7
10.2
25.4
21.6
17.2
12.7
21.6
21.6
21.6
17.7
21.4
21.4
19.0
14.5
20.9
15.9
10.9
25.6
23.4
18.4
13.4
21.8
21.8
19.3
14.3
21.6
21.6
17.6
12.6
22.6
17.0
11.5
25.8
25.1
19.6
14.0
22.0
22.0
16.4
10.9
21.8
21.8
16.2
10.7

65
10.3
11.3
8.7
12.2
9.4
13.2
10.0
9.3
7.6
5.4
5.2

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

52

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ049 (4.0 Ton)
Air on
Evaporator Coil
CFM

1000

1200

1400

1600

1800

2000

1000

1200

1400

1600

1800

2000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

79.0
68.7
58.4
54.5
78.9
68.5
58.2
54.4
54.2
78.8
68.4
58.0
54.4
54.2
78.7
68.2
57.8
54.3
54.1
62.0
52.4
49.5
49.3
55.8
47.0
44.6
44.6

3.0
2.9
2.8
2.9
3.0
2.9
2.8
2.9
2.9
2.9
2.9
2.8
2.8
2.8
2.9
2.9
2.8
2.8
2.8
3.2
3.1
3.2
3.2
3.5
3.5
3.5
3.5

29.4
35.7
42.0
54.5
32.6
39.4
46.2
54.4
54.2
35.8
43.0
50.3
54.4
54.2
38.9
46.7
54.5
54.3
54.1
44.6
50.8
49.5
49.3
42.4
47.0
44.6
44.6

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

52.8
47.4
41.9
36.1
56.2
50.4
44.6
38.4
37.7
59.6
53.4
47.3
40.7
40.0
63.0
56.5
50.0
43.0
42.3
56.7
50.1
43.2
42.4
56.9
50.3
43.3
42.6

3.4
3.4
3.4
3.3
3.5
3.5
3.4
3.3
3.3
3.5
3.5
3.5
3.4
3.4
3.6
3.5
3.5
3.4
3.4
3.5
3.5
3.4
3.4
3.5
3.5
3.4
3.4

23.9
29.8
35.7
36.1
27.2
33.7
40.3
38.4
37.7
30.5
37.7
44.9
40.7
40.0
33.8
41.6
49.4
43.0
42.3
44.9
49.9
43.2
42.4
48.3
50.3
43.3
42.6

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
25.1
20.7
65.9
3.2
31.3
27.0
22.6
58.0
3.2
37.6
33.3
28.9
24.5
50.1
3.1
51.1
39.9
35.5
31.2
26.8
45.3
3.1
27.5
22.4
67.5
3.2
34.3
29.2
24.1
59.5
3.2
41.1
36.0
30.9
25.8
51.4
3.1
52.2
43.1
38.0
32.9
27.8
46.4
3.1
54.2
46.4
41.3
36.2
31.1
46.0
3.1
29.9
24.1
69.2
3.2
37.2
31.4
25.5
60.9
3.2
44.5
38.7
32.8
27.0
52.6
3.1
53.2
46.3
40.5
34.7
28.8
47.5
3.1
54.2
50.0
44.1
38.3
32.4
47.1
3.1
32.4
25.8
70.8
3.2
40.1
33.6
27.0
62.3
3.2
47.9
41.4
34.8
28.2
53.9
3.1
54.3
49.6
43.0
36.4
29.8
48.7
3.1
54.1
53.5
46.9
40.3
33.8
48.2
3.1
37.0
29.5
22.0
59.3
3.4
43.8
36.2
28.7
21.2
51.3
3.3
49.5
47.0
39.5
32.0
24.5
46.3
3.3
49.3
49.0
41.5
34.0
26.5
45.9
3.3
33.9
25.5
17.0
56.3
3.5
39.6
31.1
22.7
14.2
48.7
3.5
44.6
44.4
36.0
27.5
19.1
44.0
3.5
44.6
44.6
36.1
27.6
19.2
43.6
3.5
95°F
19.7
15.5
49.1
3.8
25.6
21.5
17.3
43.6
3.8
31.6
27.4
23.2
19.0
38.1
3.7
36.1
33.7
29.6
25.4
21.2
33.9
3.6
22.2
17.2
51.6
3.9
28.8
23.8
18.8
45.8
3.8
35.3
30.3
25.4
20.4
40.0
3.7
38.4
37.4
32.4
27.4
22.4
35.6
3.6
37.7
36.8
31.9
26.9
21.9
35.2
3.6
24.7
18.9
54.0
3.9
31.9
26.1
20.3
48.0
3.8
39.1
33.3
27.5
21.7
42.0
3.8
40.7
41.0
35.2
29.4
23.7
37.3
3.7
40.0
40.4
34.6
28.8
23.1
36.8
3.7
27.2
20.6
56.5
3.9
35.0
28.4
21.8
50.2
3.9
42.8
36.2
29.6
23.0
43.9
3.8
43.0
44.7
38.1
31.5
24.9
39.0
3.7
42.3
44.0
37.4
30.8
24.2
38.5
3.7
37.6
30.3
23.0
49.9
3.9
46.0
38.7
31.4
24.0
43.7
3.8
43.2
44.0
36.7
29.4
22.1
38.7
3.7
42.4
43.3
36.0
28.7
21.3
38.3
3.7
40.3
32.2
24.2
49.7
3.9
49.1
41.1
33.1
25.1
43.4
3.8
43.3
43.3
35.3
27.3
19.2
38.5
3.7
42.6
42.6
34.5
26.5
18.5
38.1
3.7

90
26.7
32.8
38.9
45.3
29.9
36.6
43.2
46.4
46.0
33.1
40.4
47.6
47.5
47.1
36.4
44.2
52.0
48.7
48.2
44.7
50.3
46.3
45.9
45.3
48.7
44.0
43.6
19.3
27.0
34.7
33.9
24.5
31.1
37.7
35.6
35.2
29.6
35.1
40.7
37.3
36.8
34.7
39.2
43.6
39.0
38.5
42.3
43.5
38.7
38.3
45.4
43.4
38.5
38.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
22.4
18.1
28.5
24.2
20.0
34.6
30.3
26.1
21.8
43.6
36.8
32.6
28.3
24.8
19.8
31.5
26.5
21.4
38.2
33.1
28.1
23.1
45.3
40.3
35.2
30.2
46.0
41.6
36.6
31.6
27.3
21.5
34.5
28.7
22.9
41.8
36.0
30.2
24.3
47.0
43.7
37.9
32.1
47.1
45.2
39.4
33.6
29.8
23.2
37.6
31.0
24.4
45.4
38.8
32.2
25.6
48.7
47.1
40.5
33.9
48.2
48.7
42.1
35.6
37.3
29.9
22.5
44.9
37.5
30.0
22.6
46.3
45.5
38.1
30.7
45.9
46.1
38.7
31.3
37.1
28.9
20.6
44.4
36.1
27.9
19.6
44.0
43.9
35.6
27.4
43.6
43.6
35.3
27.1
105°F
16.9
13.0
22.9
18.9
14.8
28.9
24.7
20.7
16.6
33.9
29.9
25.8
21.8
19.5
14.6
26.1
21.2
16.2
32.7
27.8
22.8
17.9
35.6
33.6
28.7
23.7
35.2
33.2
28.3
23.3
22.1
16.1
29.3
23.5
17.7
36.5
30.8
25.0
19.2
37.3
37.3
31.5
25.6
36.8
36.9
31.0
25.2
24.7
17.7
32.5
25.8
19.1
40.3
33.9
27.2
20.5
39.0
41.0
34.3
27.6
38.5
40.5
33.8
27.1
35.1
27.6
20.2
41.6
36.3
28.9
21.5
38.7
39.7
32.3
24.9
38.3
39.3
31.9
24.4
37.6
29.5
21.3
42.8
38.7
30.6
22.4
38.5
38.5
30.4
22.2
38.1
38.1
29.9
21.8

65
24.0
25.1
26.5
26.2
27.8
27.4
29.0
23.3
23.9
19.1
18.8
17.7
18.8
18.4
19.8
19.4
20.9
20.4
17.5
17.0
14.1
13.6

53

528150-YTG-T-0514
ZJ049 (4.0 Ton) (Continued)
Air on
Evaporator Coil
CFM

1000

1200

1400

1600

1800

2000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

45.4
39.8
34.3
31.6
46.9
41.2
35.5
32.7
32.6
48.5
42.6
36.7
33.8
33.7
50.1
43.9
37.8
34.9
34.8
43.2
37.2
34.3
34.2
42.4
36.5
33.7
33.6

4.2
4.1
4.0
3.9
4.3
4.1
4.0
3.9
3.9
4.3
4.2
4.1
4.0
4.0
4.3
4.2
4.1
4.0
4.0
4.2
4.1
4.0
4.0
4.3
4.1
4.0
4.0

14.8
24.2
33.7
31.6
21.7
28.4
35.1
32.7
32.6
28.7
32.6
36.4
33.8
33.7
35.7
36.8
37.8
34.9
34.8
39.6
37.2
34.3
34.2
42.4
36.5
33.7
33.6

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
14.2
10.4
41.7
4.6
20.2
16.3
12.3
36.1
4.4
26.3
22.1
18.1
14.1
30.5
4.3
31.6
26.1
22.1
18.1
14.2
29.4
4.2
16.8
11.9
42.3
4.6
23.5
18.6
13.7
36.6
4.5
30.1
25.2
20.3
15.4
30.9
4.3
32.7
29.8
24.9
20.0
15.1
29.9
4.2
32.6
29.6
24.7
19.8
14.9
30.0
4.2
19.5
13.4
43.0
4.7
26.7
20.9
15.0
37.1
4.5
34.0
28.4
22.5
16.7
31.3
4.3
33.8
33.5
27.7
21.8
16.0
30.3
4.3
33.7
33.3
27.4
21.6
15.7
30.5
4.3
22.1
14.9
43.6
4.7
30.0
23.2
16.4
37.7
4.5
37.8
31.5
24.7
17.9
31.8
4.4
34.9
37.3
30.5
23.7
16.9
30.8
4.3
34.8
37.0
30.2
23.4
16.6
31.0
4.3
32.5
25.0
17.4
36.5
4.6
37.2
33.9
26.4
18.9
30.7
4.4
34.3
35.5
27.9
20.4
12.9
29.9
4.3
34.2
35.3
27.8
20.2
12.7
30.1
4.3
35.0
26.7
18.5
35.2
4.6
36.5
36.3
28.1
19.8
29.7
4.4
33.7
33.7
25.4
17.2
8.9
28.9
4.4
33.6
33.6
25.3
17.0
8.8
29.1
4.4

90
12.4
21.4
30.5
29.4
20.6
25.7
30.9
29.9
30.0
28.8
30.1
31.3
30.3
30.5
37.0
34.4
31.8
30.8
31.0
36.5
30.7
29.9
30.1
35.2
29.7
28.9
29.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
9.6
7.9
17.5
13.6
9.8
23.8
19.4
15.5
11.6
29.4
22.3
18.4
14.5
14.1
9.3
20.9
16.0
11.1
27.6
22.7
17.8
12.9
29.9
26.0
21.1
16.3
30.0
26.0
21.1
16.2
18.7
10.7
24.2
18.3
12.4
31.3
25.9
20.0
14.1
30.3
29.8
23.9
18.0
30.5
29.7
23.9
18.0
23.2
12.0
27.5
20.6
13.7
31.8
29.2
22.3
15.4
30.8
30.8
26.7
19.8
31.0
31.0
26.6
19.7
29.9
22.3
14.7
30.7
30.7
23.9
16.3
29.9
29.9
23.6
15.9
30.1
30.1
23.7
16.0
32.4
24.0
15.6
29.7
29.7
25.5
17.1
28.9
28.9
20.5
12.1
29.1
29.1
20.7
12.3

65
10.6
11.4
11.3
12.1
12.1
12.9
12.8
8.3
8.4
3.7
3.9

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

54

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ061 (5.0 Ton)
Air on
Evaporator Coil
CFM

1250

1500

1750

2000

2250

2500

1250

1500

1750

2000

2250

2500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

79.8
72.2
64.6
57.1
83.4
75.5
67.5
59.7
59.9
87.0
78.8
70.5
62.3
62.4
90.6
82.0
73.4
64.9
65.0
84.2
75.4
66.6
66.8
86.4
77.3
68.4
68.5

3.1
3.1
3.2
3.1
3.1
3.2
3.2
3.1
3.2
3.2
3.2
3.2
3.1
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2

35.0
42.9
50.8
57.1
38.6
47.8
57.1
59.7
59.9
42.3
52.8
63.3
62.3
62.4
45.9
57.7
69.5
64.9
65.0
62.2
73.4
66.6
66.8
66.8
77.3
68.4
68.5

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

68.5
62.1
55.7
50.1
71.1
64.5
57.8
52.0
49.8
73.7
66.8
59.9
53.9
51.6
76.3
69.2
62.0
55.8
53.4
70.6
63.3
57.0
54.5
72.0
64.6
58.1
55.7

4.1
4.1
4.0
4.0
4.1
4.1
4.1
4.0
4.0
4.2
4.1
4.1
4.0
4.0
4.2
4.1
4.1
4.0
4.0
4.2
4.1
4.0
4.0
4.2
4.1
4.0
4.0

29.0
37.6
46.2
50.1
33.4
42.4
51.5
52.0
49.8
37.8
47.3
56.7
53.9
51.6
42.2
52.1
62.0
55.8
53.4
56.4
63.3
57.0
54.5
60.7
64.6
58.1
55.7

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
28.5
22.5
74.2
3.6
36.9
30.9
24.9
67.2
3.6
45.3
39.3
33.2
27.2
60.1
3.6
57.1
47.4
41.4
35.4
29.4
53.6
3.5
31.7
24.8
77.3
3.6
40.9
34.0
27.1
70.0
3.6
50.1
43.2
36.3
29.3
62.7
3.6
59.7
52.2
45.2
38.3
31.4
55.9
3.5
59.9
55.9
49.0
42.0
35.1
54.8
3.6
34.9
27.0
80.4
3.7
44.9
37.1
29.2
72.8
3.7
55.0
47.1
39.3
31.4
65.2
3.6
62.3
56.9
49.1
41.2
33.4
58.1
3.6
62.4
61.0
53.2
45.3
37.5
57.0
3.6
38.0
29.3
83.5
3.7
48.9
40.2
31.4
75.6
3.7
59.8
51.1
42.3
33.6
67.7
3.7
64.9
61.7
52.9
44.2
35.4
60.4
3.6
65.0
66.1
57.4
48.6
39.9
59.2
3.6
52.6
43.0
33.4
77.4
3.7
64.3
54.7
45.1
35.5
69.3
3.7
66.6
65.0
55.4
45.8
36.2
61.8
3.6
66.8
67.3
57.7
48.1
38.5
60.7
3.6
56.3
45.9
35.5
79.2
3.7
68.8
58.3
47.9
37.5
70.9
3.7
68.4
68.4
57.9
47.5
37.1
63.2
3.6
68.5
68.5
58.1
47.6
37.2
62.1
3.6
95°F
23.9
18.2
63.5
4.5
32.0
26.4
20.8
57.3
4.4
40.1
34.5
28.9
23.3
51.0
4.4
50.1
41.9
36.3
30.7
25.1
46.7
4.3
26.8
20.3
65.8
4.5
35.9
29.3
22.7
59.3
4.5
44.9
38.3
31.8
25.2
52.8
4.4
52.0
46.6
40.0
33.4
26.9
48.4
4.3
49.8
44.8
38.2
31.7
25.1
46.4
4.3
29.8
22.3
68.1
4.6
39.7
32.2
24.7
61.4
4.5
49.7
42.2
34.7
27.2
54.7
4.5
53.9
51.2
43.7
36.2
28.7
50.1
4.4
51.6
49.3
41.8
34.2
26.7
48.1
4.4
32.8
24.3
70.4
4.6
43.6
35.2
26.7
63.5
4.5
54.5
46.0
37.5
29.1
56.5
4.5
55.8
55.9
47.4
38.9
30.5
51.8
4.4
53.4
53.7
45.3
36.8
28.4
49.7
4.4
47.1
37.7
28.4
64.6
4.6
58.7
49.4
40.1
30.7
57.6
4.5
57.0
57.0
47.7
38.3
29.0
52.8
4.4
54.5
54.7
45.4
36.0
26.7
50.6
4.4
50.5
40.3
30.1
65.8
4.6
63.0
52.8
42.6
32.4
58.6
4.5
58.1
58.1
48.0
37.8
27.6
53.7
4.4
55.7
55.7
45.5
35.3
25.1
51.5
4.4

90
32.0
40.3
48.5
53.6
36.0
45.1
54.3
55.9
54.8
40.0
50.0
60.0
58.1
57.0
44.0
54.9
65.7
60.4
59.2
59.3
68.3
61.8
60.7
63.7
70.9
63.2
62.1
25.6
35.7
45.7
46.7
31.5
40.4
49.3
48.4
46.4
37.3
45.1
52.9
50.1
48.1
43.1
49.8
56.5
51.8
49.7
54.1
57.6
52.8
50.6
58.3
58.6
53.7
51.5

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
26.2
20.4
34.4
28.6
22.8
42.7
36.9
31.1
25.3
53.6
44.7
38.9
33.0
29.3
22.5
38.4
31.6
24.9
47.5
40.8
34.0
27.3
55.9
49.4
42.6
35.9
54.8
50.3
43.6
36.9
32.3
24.7
42.3
34.7
27.0
52.3
44.7
37.0
29.3
58.1
54.1
46.4
38.7
57.0
55.1
47.5
39.8
35.4
26.8
46.3
37.7
29.1
57.1
48.5
39.9
31.3
60.4
58.8
50.2
41.5
59.2
59.9
51.3
42.7
49.9
40.4
30.9
61.5
52.0
42.6
33.1
61.8
61.0
51.5
42.1
60.7
61.0
51.5
42.1
53.4
43.1
32.8
65.9
55.6
45.2
34.9
63.2
63.2
52.9
42.6
62.1
62.1
51.8
41.5
105°F
22.1
16.6
30.1
24.6
19.1
38.1
32.6
27.1
21.5
46.7
38.4
32.8
27.3
25.0
18.5
33.9
27.4
20.9
42.8
36.3
29.8
23.3
48.4
42.7
36.2
29.7
46.4
41.7
35.2
28.7
27.8
20.4
37.7
30.2
22.7
47.5
40.0
32.5
25.1
50.1
47.1
39.6
32.1
48.1
45.9
38.5
31.0
30.7
22.3
41.4
33.0
24.6
52.1
43.7
35.3
26.9
51.8
51.4
43.0
34.6
49.7
50.2
41.7
33.3
44.8
35.5
26.2
55.0
47.0
37.8
28.5
52.8
52.6
43.3
34.0
50.6
50.8
41.6
32.3
48.2
38.0
27.9
57.8
50.4
40.2
30.1
53.7
53.7
43.6
33.4
51.5
51.5
41.4
31.2

65
27.2
29.1
30.1
31.0
32.1
32.9
34.1
32.6
32.6
32.3
31.1
21.8
23.2
22.2
24.7
23.5
26.2
24.9
24.7
23.0
23.3
21.1

55

528150-YTG-T-0514
ZJ061 (5.0 Ton) (Continued)
Air on
Evaporator Coil
CFM

1250

1500

1750

2000

2250

2500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

58.5
52.4
46.3
43.3
60.5
54.2
47.9
44.8
43.1
62.5
56.0
49.5
46.3
44.5
64.5
57.8
51.1
47.8
45.9
58.7
51.9
48.6
46.7
59.6
52.7
49.3
47.4

4.9
4.8
4.7
4.7
4.9
4.9
4.8
4.7
4.7
5.0
4.9
4.8
4.7
4.7
5.0
5.0
4.9
4.8
4.8
5.0
4.9
4.8
4.8
5.0
4.9
4.8
4.8

22.3
33.7
45.1
43.3
29.6
38.3
47.1
44.8
43.1
36.8
43.0
49.1
46.3
44.5
44.1
47.6
51.1
47.8
45.9
51.8
51.9
48.6
46.7
55.9
52.7
49.3
47.4

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
20.4
14.9
53.4
5.3
28.3
22.8
17.4
47.6
5.2
36.1
30.7
25.2
19.8
41.7
5.1
43.3
34.8
29.3
23.9
18.4
40.0
5.0
23.1
16.7
55.1
5.3
31.9
25.5
19.0
49.1
5.3
40.7
34.3
27.8
21.4
43.0
5.2
44.8
38.9
32.4
26.0
19.6
41.2
5.1
43.1
38.5
32.1
25.7
19.2
39.7
5.1
25.9
18.4
56.8
5.4
35.6
28.1
20.7
50.6
5.3
45.3
37.8
30.4
23.0
44.3
5.2
46.3
42.9
35.5
28.1
20.7
42.5
5.1
44.5
42.6
35.1
27.7
20.3
40.9
5.1
28.6
20.2
58.5
5.5
39.2
30.8
22.4
52.1
5.4
49.8
41.4
33.0
24.6
45.6
5.3
47.8
47.0
38.6
30.2
21.8
43.8
5.2
45.9
46.6
38.2
29.8
21.4
42.2
5.2
42.5
33.3
24.0
52.7
5.4
51.3
44.7
35.5
26.2
46.2
5.3
48.6
48.2
38.9
29.6
20.4
44.3
5.2
46.7
47.0
37.7
28.5
19.2
42.7
5.2
45.8
35.7
25.6
53.4
5.4
52.7
48.0
37.9
27.7
46.8
5.3
49.3
49.3
39.2
29.1
19.0
44.9
5.2
47.4
47.4
37.3
27.1
17.0
43.3
5.2

90
21.9
31.8
41.7
40.0
29.6
36.3
43.0
41.2
39.7
37.4
40.8
44.3
42.5
40.9
45.1
45.4
45.6
43.8
42.2
49.5
46.2
44.3
42.7
53.4
46.8
44.9
43.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
17.7
13.3
26.4
21.0
15.6
34.1
28.7
23.4
18.0
40.0
31.2
25.8
20.5
21.3
14.9
29.9
23.6
17.2
38.6
32.2
25.8
19.5
41.2
35.0
28.6
22.3
39.7
35.4
29.0
22.6
24.8
16.5
33.5
26.1
18.7
43.0
35.7
28.3
20.9
42.5
38.8
31.4
24.1
40.9
39.2
31.8
24.5
28.4
18.1
37.0
28.6
20.3
45.6
39.2
30.8
22.4
43.8
42.6
34.2
25.9
42.2
42.2
34.7
26.3
40.2
31.0
21.8
46.2
42.4
33.1
23.9
44.3
43.7
34.5
25.3
42.7
42.7
33.9
24.7
43.4
33.4
23.3
46.8
45.6
35.5
25.4
44.9
44.9
34.8
24.7
43.3
43.3
33.2
23.1

65
15.1
15.9
16.3
16.7
17.1
17.5
17.9
16.1
15.5
14.6
13.0

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

56

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ078 (6.5 Ton)
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

1625

1950

2275

2600

2925

3250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

106.7
97.0
87.2
78.3
109.7
99.7
89.6
80.4
83.1
112.6
102.3
92.1
82.6
85.3
115.6
105.0
94.5
84.8
87.6
107.5
96.7
86.7
89.6
109.9
98.8
88.7
91.6

4.6
4.5
4.5
4.6
4.6
4.6
4.5
4.6
4.6
4.6
4.6
4.5
4.6
4.6
4.6
4.6
4.5
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6

46.4
57.0
67.6
78.3
50.9
62.4
73.9
80.4
83.1
55.3
67.8
80.3
82.6
85.3
59.8
73.2
86.6
84.8
87.6
78.5
92.7
86.7
89.6
83.7
98.8
88.7
91.6

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

89.6
81.5
73.4
65.8
92.3
84.0
75.6
67.8
65.4
95.0
86.4
77.8
69.8
67.2
97.6
88.8
80.0
71.7
69.1
90.7
81.7
73.3
70.6
92.7
83.5
74.8
72.1

5.6
5.5
5.5
5.4
5.6
5.6
5.5
5.5
5.4
5.7
5.6
5.5
5.5
5.5
5.7
5.6
5.6
5.5
5.5
5.7
5.6
5.5
5.5
5.7
5.6
5.5
5.5

38.5
49.3
60.2
65.8
43.2
55.0
66.8
67.8
65.4
48.0
60.7
73.4
69.8
67.2
52.7
66.4
80.0
71.7
69.1
70.9
81.7
73.3
70.6
75.4
83.5
74.8
72.1

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
38.6
31.0
98.2
5.1
49.4
41.7
34.1
89.3
5.0
60.1
52.4
44.8
37.2
80.3
5.0
71.0
62.1
54.4
46.8
39.1
72.1
5.0
42.2
33.4
101.0
5.1
53.7
45.0
36.2
91.8
5.1
65.2
56.5
47.8
39.1
82.6
5.0
75.6
66.9
58.1
49.4
40.7
74.1
5.0
83.1
72.0
63.2
54.5
45.8
74.2
5.0
45.7
35.9
103.8
5.1
58.0
48.2
38.4
94.4
5.1
70.4
60.6
50.8
41.0
84.9
5.0
80.2
71.7
61.9
52.1
42.3
76.2
5.0
85.3
77.1
67.3
57.5
47.7
76.3
5.0
49.2
38.3
106.6
5.2
62.3
51.4
40.6
96.9
5.1
75.5
64.6
53.7
42.9
87.2
5.1
84.8
76.5
65.6
54.7
43.8
78.2
5.1
87.6
82.3
71.4
60.6
49.7
78.4
5.0
66.6
54.8
43.0
99.1
5.1
80.7
68.8
57.0
45.2
89.2
5.1
86.7
82.6
70.8
58.9
47.1
80.0
5.1
89.6
87.0
75.2
63.3
51.5
80.1
5.1
70.9
58.2
45.4
101.3
5.1
85.8
73.1
60.3
47.5
91.2
5.1
88.7
88.7
75.9
63.2
50.4
81.8
5.1
91.6
91.6
78.9
66.1
53.3
81.9
5.1
95°F
31.4
24.3
80.9
6.2
42.2
35.0
27.9
73.1
6.1
52.9
45.8
38.6
31.5
65.3
6.0
64.2
53.3
46.1
39.0
31.8
58.3
5.9
34.9
26.6
83.8
6.2
46.7
38.4
30.1
75.7
6.1
58.5
50.2
41.9
33.6
67.7
6.0
66.7
58.4
50.1
41.8
33.5
60.4
5.9
65.4
61.9
53.6
45.3
37.0
61.0
5.9
38.4
29.0
86.7
6.3
51.2
41.8
32.3
78.4
6.1
64.0
54.6
45.1
35.7
70.1
6.0
69.2
63.5
54.1
44.6
35.2
62.5
5.9
67.2
67.3
57.9
48.4
39.0
63.2
6.0
41.9
31.3
89.7
6.3
55.8
45.1
34.5
81.0
6.2
69.6
59.0
48.4
37.8
72.4
6.1
71.7
68.7
58.1
47.5
36.8
64.6
6.0
69.1
72.8
62.2
51.6
40.9
65.3
6.0
59.4
47.9
36.5
82.6
6.2
74.1
62.7
51.2
39.7
73.8
6.1
73.3
71.7
60.3
48.8
37.4
65.9
6.0
70.6
72.5
61.0
49.5
38.1
66.6
6.0
63.1
50.7
38.4
84.2
6.2
78.6
66.3
54.0
41.7
75.2
6.1
74.8
74.8
62.5
50.2
37.9
67.1
6.0
72.1
72.1
59.8
47.5
35.2
67.8
6.0

90
42.4
53.2
63.9
72.1
47.1
58.7
70.4
74.1
74.2
51.7
64.2
76.8
76.2
76.3
56.3
69.8
83.3
78.2
78.4
74.7
87.2
80.0
80.1
79.5
91.2
81.8
81.9
33.0
45.5
57.9
58.3
40.0
51.4
62.8
60.4
61.0
46.9
57.2
67.6
62.5
63.2
53.8
63.1
72.4
64.6
65.3
67.2
73.8
65.9
66.6
71.3
75.2
67.1
67.8

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
35.0
27.6
45.8
38.4
31.0
56.5
49.1
41.7
34.3
67.6
57.7
50.3
42.9
38.5
30.0
50.2
41.7
33.2
61.9
53.3
44.8
36.3
71.1
62.6
54.1
45.6
74.2
66.9
58.4
49.9
42.0
32.4
54.6
45.0
35.4
67.2
57.6
47.9
38.3
74.7
67.6
58.0
48.3
76.3
72.2
62.6
53.0
45.5
34.8
59.0
48.3
37.6
72.5
61.8
51.1
40.3
78.2
72.6
61.8
51.1
78.4
77.6
66.8
56.1
63.0
51.4
39.7
77.4
65.7
54.1
42.5
80.0
77.2
65.5
53.9
80.1
79.7
68.1
56.4
67.0
54.5
41.9
82.2
69.7
57.2
44.6
81.8
81.8
69.2
56.7
81.9
81.9
69.3
56.8
105°F
28.4
21.5
38.6
31.8
25.0
48.9
42.1
35.2
28.4
57.5
47.9
41.1
34.2
31.9
23.9
43.3
35.3
27.2
54.7
46.7
38.6
30.5
59.9
53.1
45.0
37.0
61.0
55.7
47.7
39.6
35.5
26.2
48.0
38.7
29.4
60.5
51.2
42.0
32.7
62.2
58.3
49.0
39.7
63.2
61.2
51.9
42.6
39.0
28.5
52.6
42.2
31.7
66.3
55.8
45.3
34.8
64.6
63.5
53.0
42.5
65.3
66.6
56.1
45.7
55.9
44.7
33.4
69.5
59.1
47.8
36.6
65.9
65.3
54.0
42.7
66.6
67.2
55.9
44.7
59.2
47.2
35.1
72.8
62.4
50.4
38.3
67.1
67.1
55.1
43.0
67.8
67.8
55.7
43.7

65
35.5
37.1
41.4
38.7
43.4
40.3
45.3
42.2
44.8
44.1
44.3
27.4
28.9
31.6
30.5
33.4
32.0
35.2
31.5
33.4
30.9
31.6

57

528150-YTG-T-0514
ZJ078 (6.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

72.1
64.6
57.2
50.7
75.3
67.5
59.8
53.0
56.6
78.5
70.4
62.3
55.3
59.1
81.7
73.3
64.9
57.5
61.5
74.5
65.9
58.5
62.5
75.7
67.0
59.4
63.5

6.8
6.6
6.4
6.3
6.8
6.6
6.5
6.4
6.4
6.8
6.7
6.5
6.4
6.4
6.9
6.7
6.6
6.4
6.5
6.7
6.6
6.5
6.5
6.8
6.6
6.5
6.5

27.6
41.6
55.6
50.7
36.7
47.7
58.7
53.0
56.6
45.8
53.8
61.8
55.3
59.1
54.9
59.9
64.9
57.5
61.5
63.6
65.9
58.5
62.5
67.3
67.0
59.4
63.5

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
25.3
18.8
63.3
7.3
35.1
28.6
22.1
56.2
7.1
44.9
38.4
31.9
25.4
49.1
6.9
50.7
42.5
36.0
29.5
23.0
43.2
6.8
28.9
21.1
66.8
7.4
39.9
32.1
24.3
59.3
7.2
50.9
43.1
35.3
27.5
51.8
7.0
53.0
47.8
40.0
32.2
24.4
45.6
6.8
56.6
49.6
41.8
34.0
26.2
52.3
6.9
32.5
23.4
70.2
7.4
44.7
35.6
26.6
62.4
7.2
56.9
47.8
38.8
29.7
54.6
7.0
55.3
53.0
43.9
34.9
25.8
48.0
6.8
59.1
55.0
46.0
36.9
27.8
55.0
6.9
36.1
25.7
73.7
7.5
49.5
39.2
28.8
65.5
7.2
62.9
52.6
42.2
31.9
57.3
7.0
57.5
58.3
47.9
37.5
27.2
50.4
6.9
61.5
60.5
50.1
39.7
29.4
57.6
7.0
52.5
41.4
30.3
66.4
7.3
65.0
55.6
44.5
33.4
58.0
7.1
58.5
58.8
47.7
36.6
25.5
51.1
6.9
62.5
62.0
50.9
39.8
28.7
58.4
7.0
55.4
43.6
31.8
67.2
7.3
67.0
58.5
46.7
34.9
58.8
7.1
59.4
59.4
47.6
35.8
23.9
51.7
7.0
63.5
63.5
51.7
39.8
28.0
59.2
7.1

90
26.5
37.8
49.1
43.2
36.3
44.1
51.8
45.6
52.3
46.1
50.3
54.6
48.0
55.0
56.0
56.6
57.3
50.4
57.6
59.9
58.0
51.1
58.4
63.2
58.8
51.7
59.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
21.1
16.1
31.6
25.4
19.2
40.9
34.7
28.5
22.3
43.2
37.2
31.0
24.8
25.9
18.4
36.5
29.0
21.4
47.1
39.6
32.1
24.5
45.6
42.5
34.9
27.4
52.3
43.4
35.9
28.4
30.7
20.7
41.5
32.6
23.7
53.4
44.5
35.6
26.7
48.0
47.8
38.9
30.0
55.0
48.9
40.0
31.1
35.5
23.0
46.4
36.2
25.9
57.3
49.4
39.1
28.9
50.4
50.4
42.8
32.6
57.6
54.3
44.1
33.8
49.0
38.1
27.2
58.0
52.0
41.1
30.2
51.1
51.1
41.5
30.6
58.4
56.8
45.8
34.9
51.6
40.0
28.4
58.8
54.7
43.1
31.5
51.7
51.7
40.1
28.5
59.2
59.2
47.6
36.0

65
18.6
19.8
20.8
21.1
22.2
22.3
23.6
19.6
24.0
16.9
24.4

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

58

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ090 (7.5 Ton)
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

1875

2250

2625

3000

3375

3750

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

125.0
113.1
101.1
88.8
131.0
118.5
106.0
93.1
93.6
137.0
123.9
110.8
97.3
97.8
142.9
129.3
115.7
101.6
102.1
132.4
118.4
104.0
104.6
135.5
121.2
106.4
107.0

5.7
5.6
5.6
5.5
5.7
5.7
5.6
5.6
5.5
5.7
5.7
5.6
5.6
5.6
5.8
5.7
5.7
5.6
5.6
5.7
5.7
5.6
5.6
5.7
5.7
5.6
5.6

53.1
65.8
78.5
88.8
59.5
73.4
87.3
93.1
93.6
65.8
80.9
96.1
97.3
97.8
72.1
88.5
104.9
101.6
102.1
95.5
113.0
104.0
104.6
102.5
121.2
106.4
107.0

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

107.8
97.6
87.4
77.1
111.8
101.2
90.6
79.9
81.1
115.7
104.8
93.8
82.8
84.0
119.7
108.3
97.0
85.6
86.8
110.7
99.2
87.5
88.8
113.1
101.3
89.4
90.7

7.0
6.9
6.7
6.6
7.1
6.9
6.8
6.7
6.6
7.1
7.0
6.8
6.7
6.7
7.2
7.0
6.9
6.8
6.7
7.0
6.9
6.8
6.7
7.0
6.9
6.8
6.8

45.3
58.6
71.9
77.1
50.8
65.4
79.9
79.9
81.1
56.3
72.1
88.0
82.8
84.0
61.8
78.9
96.0
85.6
86.8
86.0
98.6
87.5
88.8
93.0
101.3
89.4
90.7

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
44.4
35.6
116.4
6.3
57.1
48.3
39.5
105.3
6.2
69.8
61.0
52.2
43.5
94.3
6.1
88.8
73.3
64.6
55.8
47.0
83.0
6.1
49.2
39.0
121.4
6.4
63.2
52.9
42.7
109.8
6.3
77.1
66.8
56.6
46.4
98.3
6.2
93.1
80.4
70.2
59.9
49.7
86.5
6.1
93.6
87.2
77.0
66.8
56.5
87.3
6.1
54.1
42.4
126.3
6.4
69.3
57.6
45.9
114.3
6.3
84.4
72.7
61.0
49.3
102.3
6.2
97.3
87.5
75.8
64.1
52.4
90.0
6.1
97.8
94.9
83.2
71.5
59.8
90.9
6.1
59.0
45.8
131.3
6.5
75.4
62.2
49.1
118.8
6.4
91.7
78.6
65.4
52.3
106.3
6.3
101.6 94.5
81.3
68.2
55.0
93.6
6.2
102.1 102.5 89.4
76.2
63.1
94.5
6.2
80.9
66.2
51.6
121.6
6.4
98.3
83.7
69.0
54.4
108.8
6.3
104.0 100.5 85.8
71.2
56.6
95.7
6.2
104.6 104.8 90.1
75.5
60.9
96.7
6.2
86.4
70.3
54.2
124.3
6.4
104.8 88.7
72.7
56.6
111.2
6.3
106.4 106.4 90.3
74.2
58.2
97.9
6.2
107.0 107.0 90.9
74.8
58.7
98.8
6.2
95°F
36.6
27.9
99.1
7.6
49.9
41.2
32.5
89.4
7.5
63.2
54.5
45.8
37.1
79.6
7.3
77.1
67.2
58.4
49.7
41.0
70.5
7.1
40.7
30.5
102.3
7.7
55.2
45.1
35.0
92.2
7.5
69.8
59.7
49.5
39.4
82.2
7.3
79.9
73.5
63.4
53.2
43.1
72.7
7.2
81.1
72.4
62.2
52.1
42.0
75.0
7.2
44.7
33.2
105.4
7.8
60.6
49.0
37.4
95.1
7.6
76.4
64.8
53.3
41.7
84.7
7.4
82.8
79.9
68.3
56.8
45.2
75.0
7.2
84.0
78.6
67.1
55.5
43.9
77.3
7.2
48.8
35.8
108.6
7.8
65.9
52.9
39.9
97.9
7.6
83.0
70.0
57.0
44.0
87.3
7.4
85.6
86.3
73.3
60.3
47.3
77.2
7.3
86.8
84.9
71.9
58.9
45.9
79.6
7.3
71.5
57.0
42.5
99.7
7.7
89.9
75.4
60.9
46.4
88.9
7.5
87.5
87.8
73.3
58.8
44.3
78.7
7.3
88.8
87.8
73.3
58.8
44.3
81.1
7.3
77.0
61.0
45.0
101.6
7.7
96.7
80.7
64.7
48.7
90.5
7.5
89.4
89.4
73.4
57.4
41.4
80.1
7.3
90.7
90.7
74.7
58.7
42.7
82.5
7.3

90
49.2
62.2
75.2
83.0
55.1
69.4
83.6
86.5
87.3
61.1
76.5
92.0
90.0
90.9
67.0
83.7
100.4
93.6
94.5
90.7
105.8
95.7
96.7
97.7
111.2
97.9
98.8
39.5
55.1
70.7
70.5
47.3
61.7
76.1
72.7
75.0
55.1
68.3
81.4
75.0
77.3
62.9
74.8
86.7
77.2
79.6
81.7
88.6
78.7
81.1
88.6
90.5
80.1
82.5

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
40.5
31.7
53.5
44.7
36.0
66.5
57.7
49.0
40.3
83.0
70.3
61.5
52.8
45.0
34.8
59.2
49.0
38.8
73.4
63.3
53.1
42.9
86.5
77.0
66.8
56.6
87.3
79.8
69.6
59.4
49.4
37.8
64.9
53.3
41.7
80.4
68.8
57.1
45.5
90.0
83.7
72.0
60.4
90.9
86.8
75.1
63.5
53.9
40.8
70.6
57.6
44.5
87.4
74.3
61.2
48.1
93.6
90.4
77.3
64.2
94.5
93.7
80.6
67.6
76.2
61.6
47.0
94.1
79.5
65.0
50.4
95.7
94.1
79.6
65.0
96.7
96.3
81.7
67.2
81.7
65.7
49.6
100.8 84.7
68.7
52.7
97.9
97.9
81.9
65.8
98.8
98.8
82.8
66.8
105°F
33.4
24.8
46.5
37.9
29.3
59.6
51.0
42.4
33.8
70.5
63.1
54.5
45.9
37.3
27.3
51.7
41.7
31.6
66.0
56.0
46.0
36.0
72.7
69.3
59.3
49.3
75.0
66.9
56.9
46.9
41.1
29.7
56.8
45.4
34.0
72.5
61.1
49.6
38.2
75.0
75.5
64.1
52.7
77.3
72.9
61.5
50.1
45.0
32.2
62.0
49.1
36.3
79.0
66.1
53.3
40.4
77.2
81.8
68.9
56.0
79.6
78.9
66.1
53.2
67.4
53.0
38.6
83.6
71.3
57.0
42.6
78.7
80.9
66.6
52.2
81.1
80.7
66.4
52.0
72.8
56.9
41.0
88.2
76.5
60.7
44.8
80.1
80.1
64.3
48.4
82.5
82.5
66.7
50.8

65
44.0
46.4
49.2
48.8
51.9
51.2
54.5
50.5
52.6
49.8
50.7
37.3
39.3
36.9
41.2
38.6
43.2
40.4
37.9
37.7
32.5
34.9

59

528150-YTG-T-0514
ZJ090 (7.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

90.4
81.1
71.9
63.9
92.7
83.2
73.7
65.6
68.8
95.1
85.4
75.6
67.2
70.6
97.5
87.5
77.5
68.9
72.3
88.7
78.6
69.9
73.4
90.0
79.7
70.9
74.4

8.3
8.0
7.8
7.6
8.3
8.1
7.9
7.7
7.7
8.4
8.2
7.9
7.7
7.8
8.5
8.2
8.0
7.8
7.9
8.3
8.0
7.8
7.9
8.3
8.1
7.9
7.9

33.6
51.6
69.5
63.9
43.8
58.0
72.2
65.6
68.8
53.9
64.4
74.8
67.2
70.6
64.0
70.8
77.5
68.9
72.3
77.5
78.6
69.9
73.4
84.3
79.7
70.9
74.4

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
30.2
21.8
81.7
8.9
43.1
34.6
26.2
72.9
8.6
56.0
47.5
39.0
30.6
64.1
8.3
63.9
59.0
50.5
42.0
33.6
57.3
8.1
33.9
24.0
83.2
9.0
48.1
38.2
28.3
74.3
8.7
62.3
52.4
42.5
32.6
65.3
8.4
65.6
65.1
55.2
45.3
35.4
58.4
8.2
68.8
61.5
51.6
41.7
31.8
62.7
8.3
37.5
26.3
84.8
9.1
53.1
41.8
30.5
75.7
8.8
68.6
57.3
46.0
34.7
66.5
8.5
67.2
71.2
59.9
48.6
37.3
59.5
8.2
70.6
67.2
55.9
44.6
33.3
63.9
8.4
41.2
28.5
86.4
9.1
58.1
45.4
32.6
77.1
8.8
74.9
62.2
49.5
36.8
67.8
8.6
68.9
77.2
64.5
51.8
39.1
60.6
8.3
72.3
73.0
60.3
47.6
34.8
65.1
8.4
63.3
49.1
34.8
77.7
8.9
77.3
67.3
53.1
38.8
68.3
8.6
69.9
74.1
59.8
45.6
31.4
61.1
8.4
73.4
73.7
59.5
45.2
31.0
65.7
8.5
68.5
52.8
37.0
78.4
8.9
79.7
72.4
56.6
40.9
68.9
8.6
70.9
70.9
55.1
39.4
23.6
61.6
8.4
74.4
74.4
58.7
42.9
27.2
66.3
8.5

90
32.0
48.1
64.1
57.3
43.2
54.3
65.3
58.4
62.7
54.4
60.5
66.5
59.5
63.9
65.7
66.7
67.8
60.6
65.1
73.3
68.3
61.1
65.7
78.4
68.9
61.6
66.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
25.5
18.7
39.7
31.4
23.0
52.4
44.0
35.7
27.3
57.3
57.3
46.5
38.2
30.5
20.7
44.5
34.8
25.0
58.5
48.8
39.0
29.3
58.4
58.4
51.1
41.3
62.7
56.0
46.3
36.5
35.5
22.8
49.3
38.2
27.0
64.7
53.5
42.4
31.2
59.5
59.5
55.6
44.5
63.9
61.5
50.4
39.2
40.5
24.8
54.1
41.6
29.0
67.8
58.3
45.8
33.2
60.6
60.6
60.2
47.6
65.1
65.1
54.4
41.9
59.2
45.1
31.0
68.3
63.3
49.2
35.1
61.1
61.1
53.1
39.0
65.7
65.7
52.5
38.4
64.3
48.6
33.0
68.9
68.2
52.6
37.0
61.6
61.6
46.0
30.4
66.3
66.3
50.6
35.0

65
29.8
31.6
26.8
33.3
28.0
35.0
29.3
24.9
24.3
14.8
19.4

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

60

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ102 (8.5 Ton)
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

2125

2550

2975

3400

3825

4250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

136.0
124.0
112.1
99.3
141.0
128.6
116.2
102.9
99.4
146.0
133.1
120.3
106.5
102.9
151.0
137.7
124.4
110.2
106.5
141.1
127.5
112.9
109.1
144.5
130.6
115.6
111.7

6.1
6.0
5.9
6.2
6.1
6.0
5.9
6.2
8.7
6.1
6.0
5.9
6.1
8.7
6.0
5.9
5.8
6.1
8.7
6.0
5.9
6.2
8.7
6.1
6.0
6.2
8.8

61.5
74.1
86.7
99.3
67.2
82.2
97.3
102.9
99.4
72.8
90.4
107.9
106.5
102.9
78.5
98.5
118.5
110.2
106.5
105.2
124.6
112.9
109.1
112.0
130.6
115.6
111.7

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

119.3
107.9
96.5
84.0
123.1
111.4
99.7
86.7
87.7
127.0
114.9
102.8
89.5
90.5
130.9
118.5
106.0
92.2
93.3
121.0
108.3
94.2
95.3
123.5
110.5
96.2
97.3

7.4
7.3
7.2
7.3
7.5
7.4
7.2
7.3
7.1
7.5
7.4
7.3
7.4
7.2
7.6
7.4
7.3
7.4
7.2
7.5
7.3
7.4
7.2
7.5
7.4
7.5
7.3

51.1
66.3
81.5
84.0
58.8
74.2
89.7
86.7
87.7
66.6
82.2
97.8
89.5
90.5
74.3
90.2
106.0
92.2
93.3
97.1
108.3
94.2
95.3
104.1
110.5
96.2
97.3

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
49.5
38.6
127.6
6.8
63.2
52.4
41.5
116.0
6.7
77.0
66.1
55.3
44.4
104.3
6.6
95.1
77.6
66.8
55.9
45.0
91.6
6.7
54.7
42.3
132.1
6.8
69.8
57.4
44.9
120.0
6.7
84.9
72.5
60.0
47.6
107.9
6.6
100.1 85.0
72.6
60.1
47.7
94.8
6.7
99.4
91.2
78.7
66.3
53.8
93.6
6.5
60.0
46.0
136.5
6.8
76.4
62.4
48.4
124.0
6.7
92.8
78.8
64.8
50.8
111.6
6.6
105.1 92.4
78.4
64.4
50.4
98.0
6.7
102.9 99.1
85.1
71.1
57.1
96.7
6.5
65.2
49.7
141.0
6.8
82.9
67.4
51.8
128.1
6.7
100.6 85.1
69.5
53.9
115.2
6.6
110.2 99.8
84.3
68.7
53.1
101.2
6.8
106.5 107.0 91.5
75.9
60.3
99.9
6.5
88.2
71.1
54.0
131.1
6.7
106.8 89.8
72.7
55.6
117.9
6.6
112.9 107.7 90.6
73.6
56.5
103.5
6.8
109.1 109.4 92.3
75.2
58.2
102.2
6.6
93.4
74.8
56.3
134.0
6.8
113.0 94.5
75.9
57.3
120.6
6.7
115.6 115.6 97.0
78.4
59.9
105.9
6.8
111.7 111.7 93.2
74.6
56.0
104.5
6.6
95°F
41.8
31.4
108.3
8.2
55.9
45.4
35.0
97.7
8.0
69.9
59.5
49.1
38.6
87.1
7.8
84.0
70.3
59.9
49.5
39.1
77.3
7.9
46.7
34.5
111.8
8.2
62.1
49.9
37.7
100.9
8.1
77.5
65.3
53.1
41.0
90.0
7.9
86.7
77.2
65.1
52.9
40.7
79.8
7.9
87.7
79.5
67.4
55.2
43.0
80.7
7.8
51.5
37.6
115.3
8.3
68.3
54.4
40.5
104.1
8.1
85.1
71.2
57.2
43.3
92.8
7.9
89.5
84.1
70.2
56.3
42.4
82.3
7.9
90.5
86.6
72.7
58.8
44.9
83.2
7.8
56.3
40.7
118.9
8.3
74.5
58.8
43.2
107.3
8.1
92.7
77.0
61.3
45.7
95.7
8.0
92.2
91.0
75.4
59.7
44.1
84.8
8.0
93.3
93.8
78.1
62.4
46.8
85.8
7.8
80.1
63.0
46.0
109.5
8.2
99.5
82.5
65.4
48.4
97.7
8.0
94.2
93.6
76.5
59.5
42.5
86.6
8.0
95.3
95.5
78.5
61.4
44.4
87.5
7.9
85.6
67.2
48.8
111.7
8.2
106.4 87.9
69.5
51.1
99.6
8.0
96.2
96.2
77.7
59.3
40.8
88.4
8.0
97.3
97.3
78.8
60.4
41.9
89.3
7.9

90
56.3
70.2
84.1
91.6
63.0
78.2
93.5
94.8
93.6
69.7
86.3
102.9
98.0
96.7
76.4
94.3
112.3
101.2
99.9
101.2
116.4
103.5
102.2
108.0
120.6
105.9
104.5
44.7
62.2
79.6
77.3
55.2
70.1
85.0
79.8
80.7
65.6
78.0
90.3
82.3
83.2
76.1
85.9
95.7
84.8
85.8
92.8
97.7
86.6
87.5
99.6
99.6
88.4
89.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
45.7
35.0
59.6
48.9
38.3
73.5
62.8
52.2
41.5
89.5
74.0
63.3
52.7
50.7
38.4
65.9
53.6
41.3
81.2
68.9
56.6
44.3
93.4
81.1
68.8
56.5
93.6
85.3
73.0
60.7
55.7
41.8
72.3
58.4
44.4
88.9
75.0
61.0
47.0
97.3
88.3
74.3
60.4
96.7
92.9
78.9
65.0
60.8
45.2
78.7
63.1
47.5
96.6
81.0
65.4
49.8
101.2 95.4
79.8
64.2
99.9 100.4 84.8
69.2
84.1
67.1
50.0
103.2 86.1
69.1
52.0
103.5 100.7 83.6
66.5
102.2 102.4 85.4
68.3
89.5
71.0
52.5
109.7 91.2
72.7
54.2
105.9 105.9 87.4
68.9
104.5 104.5 86.0
67.5
105°F
38.5
28.3
52.0
41.8
31.6
65.5
55.3
45.1
34.9
77.3
65.1
54.9
44.7
43.2
31.2
58.1
46.2
34.2
73.0
61.1
49.1
37.2
79.8
71.9
60.0
48.0
80.7
72.5
60.5
48.6
47.9
34.2
64.3
50.6
36.9
80.6
66.9
53.2
39.5
82.3
78.8
65.1
51.4
83.2
79.4
65.7
51.9
52.6
37.2
70.4
55.0
39.5
88.2
72.7
57.3
41.8
84.8
85.6
70.2
54.7
85.8
86.3
70.8
55.3
75.9
59.0
42.1
92.9
78.1
61.2
44.3
86.6
87.0
70.1
53.2
87.5
87.8
70.9
54.0
81.3
63.0
44.7
97.6
83.4
65.1
46.8
88.4
88.4
70.1
51.7
89.3
89.3
71.0
52.7

65
42.0
44.2
48.4
46.4
51.0
48.6
53.6
49.5
51.3
50.4
49.0
34.5
36.1
36.6
37.6
38.2
39.2
39.9
36.3
37.1
33.4
34.4

61

528150-YTG-T-0514
ZJ102 (8.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

97.3
87.5
77.8
70.6
100.5
90.4
80.3
72.9
73.6
103.6
93.2
82.8
75.2
75.9
106.8
96.1
85.3
77.5
78.3
98.0
87.0
79.0
79.8
99.9
88.8
80.6
81.4

9.0
8.7
8.5
8.4
9.0
8.8
8.5
8.4
8.4
9.1
8.8
8.6
8.5
8.4
9.1
8.9
8.6
8.5
8.4
8.9
8.7
8.6
8.5
8.9
8.7
8.6
8.5

38.3
58.0
77.8
70.6
51.5
65.9
80.3
72.9
73.6
64.7
73.7
82.8
75.2
75.9
77.9
81.6
85.3
77.5
78.3
88.4
87.0
79.0
79.8
95.2
88.8
80.6
81.4

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
35.1
25.1
86.3
9.7
48.0
38.1
28.1
77.4
9.4
61.0
51.1
41.1
31.1
68.4
9.1
70.6
59.8
49.8
39.8
29.9
63.9
9.0
39.7
28.0
89.1
9.8
54.1
42.4
30.7
79.9
9.5
68.6
56.9
45.1
33.4
70.6
9.2
72.9
66.6
54.9
43.1
31.4
66.0
9.0
73.6
65.4
53.7
41.9
30.2
66.6
10.4
44.3
30.8
91.9
9.8
60.2
46.7
33.2
82.4
9.5
76.2
62.7
49.2
35.7
72.8
9.2
75.2
73.4
59.9
46.4
32.9
68.0
9.0
75.9
72.1
58.6
45.1
31.6
68.7
10.4
48.9
33.7
94.7
9.9
66.3
51.1
35.8
84.9
9.6
83.8
68.5
53.2
38.0
75.0
9.3
77.5
80.2
64.9
49.7
34.4
70.1
9.1
78.3
78.8
63.5
48.2
33.0
70.7
10.5
71.7
55.0
38.2
86.5
9.6
86.3
73.7
57.0
40.3
76.4
9.3
79.0
80.4
63.7
46.9
30.2
71.4
9.1
79.8
80.1
63.4
46.6
29.9
72.1
10.5
77.0
58.8
40.7
88.1
9.7
88.8
78.9
60.7
42.5
77.9
9.4
80.6
80.6
62.4
44.2
26.0
72.8
9.2
81.4
81.4
63.2
45.0
26.9
73.5
10.6

90
39.4
53.9
68.4
63.9
52.8
61.7
70.6
66.0
66.6
66.2
69.5
72.8
68.0
68.7
79.6
77.3
75.0
70.1
70.7
84.0
76.4
71.4
72.1
88.1
77.9
72.8
73.5

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
29.5
21.9
44.1
34.4
24.6
56.6
46.8
37.1
27.4
63.9
54.5
44.8
35.0
36.2
24.7
50.2
38.7
27.1
64.2
52.6
41.1
29.6
66.0
61.3
49.8
38.2
66.6
58.3
46.8
35.3
42.9
27.4
56.2
42.9
29.6
71.7
58.4
45.2
31.9
68.0
68.0
54.7
41.5
68.7
64.8
51.5
38.2
49.5
30.2
62.3
47.2
32.1
75.0
64.2
49.2
34.1
70.1
70.1
59.7
44.7
70.7
70.7
56.2
41.1
67.5
50.9
34.4
76.4
69.3
52.8
36.2
71.4
71.4
57.2
40.7
72.1
72.1
55.8
39.2
72.7
54.7
36.6
77.9
74.4
56.3
38.3
72.8
72.8
54.7
36.7
73.5
73.5
55.4
37.4

65
25.3
26.7
23.8
28.2
24.9
29.6
26.1
24.1
22.7
18.6
19.3

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

62

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ120 (10 Ton)
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

2500

3000

3500

4000

4500

5000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

159.5
145.9
132.2
123.1
164.8
150.7
136.6
127.2
125.9
170.1
155.5
140.9
131.2
129.9
175.4
160.3
145.3
135.3
133.9
164.1
148.7
138.4
137.0
167.8
152.0
141.6
140.1

7.3
7.2
7.1
7.0
7.4
7.2
7.1
7.0
7.0
7.4
7.3
7.1
7.1
7.0
7.4
7.3
7.2
7.1
7.1
7.4
7.2
7.1
7.1
7.4
7.3
7.2
7.2

63.5
83.1
102.7
123.1
71.2
92.6
114.0
127.2
125.9
78.9
102.1
125.4
131.2
129.9
86.6
111.7
136.7
135.3
133.9
118.0
144.4
138.4
137.0
124.3
152.0
141.6
140.1

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

136.9
126.4
115.8
106.6
142.5
131.5
120.5
110.9
111.2
148.1
136.7
125.3
115.3
115.6
153.7
141.9
130.0
119.6
120.0
143.9
131.8
121.3
121.7
145.9
133.7
123.0
123.4

9.0
8.9
8.9
8.8
9.0
9.0
8.9
8.8
8.8
9.1
9.0
9.0
8.9
8.9
9.1
9.0
9.0
8.9
8.9
9.1
9.0
8.9
8.9
9.1
9.0
8.9
8.9

58.8
77.3
95.9
106.6
66.0
86.3
106.7
110.9
111.2
73.2
95.4
117.5
115.3
115.6
80.4
104.4
128.3
119.6
120.0
113.1
131.0
121.3
121.7
121.9
133.7
123.0
123.4

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
52.6
41.7
148.2
8.2
72.2
61.3
50.4
136.1
8.1
91.8
80.9
70.0
59.1
124.0
8.0
118.4 99.0
88.1
77.2
66.3
114.8
7.9
58.4
45.5
153.7
8.2
79.8
67.0
54.2
141.1
8.1
101.2 88.4
75.6
62.8
128.6
8.0
124.1 108.2 95.4
82.6
69.8
119.0
7.9
125.9 113.4 100.6 87.8
75.0
118.5
7.9
64.2
49.4
159.1
8.2
87.4
72.7
57.9
146.1
8.1
110.6 95.9
81.2
66.5
133.1
8.1
129.7 117.5 102.7 88.0
73.3
123.3
8.0
129.9 123.1 108.3 93.6
78.9
122.7
7.9
70.0
53.3
164.5
8.3
95.0
78.4
61.7
151.1
8.2
120.1 103.4 86.8
70.1
137.6
8.1
135.3 126.7 110.0 93.4
76.7
127.5
8.0
133.9 132.7 116.1 99.4
82.8
126.9
8.0
100.1 82.2
64.4
154.0
8.2
126.4 108.5 90.7
72.8
140.3
8.1
138.4 134.1 116.3 98.4
80.5
129.9
8.0
137.0 136.4 118.6 100.7 82.8
129.3
8.0
105.2 86.1
67.0
156.8
8.2
132.7 113.6 94.5
75.5
142.9
8.1
141.6 141.6 122.5 103.4 84.3
132.3
8.0
140.1 140.1 121.0 101.9 82.9
131.7
8.0
95°F
47.9
37.1
125.0
10.0
66.5
55.6
44.8
115.5
10.0
85.0
74.1
63.3
52.4
105.9
10.0
106.6 92.2
81.4
70.5
59.7
98.2
9.9
53.4
40.7
131.1
10.1
73.7
61.1
48.5
121.1
10.0
94.1
81.4
68.8
56.2
111.1
10.0
110.9 101.3 88.7
76.0
63.4
102.9
9.9
111.2 100.9 88.2
75.6
63.0
103.1
9.9
58.8
44.4
137.1
10.1
80.9
66.5
52.1
126.7
10.1
103.1 88.7
74.3
59.9
116.2
10.1
115.3 110.4 96.0
81.6
67.2
107.7
10.0
115.6 109.9 95.5
81.1
66.7
107.9
9.9
64.2
48.0
143.2
10.2
88.2
72.0
55.8
132.3
10.2
112.2 96.0
79.8
63.7
121.4
10.1
119.6 119.4 103.3 87.1
70.9
112.5
10.0
120.0 118.9 102.7 86.6
70.4
112.6
10.0
95.2
77.3
59.4
133.6
10.1
121.0 103.1 85.2
67.3
122.6
10.1
121.3 121.2 103.3 85.4
67.5
113.6
10.0
121.7 121.1 103.2 85.3
67.5
113.8
10.0
102.3 82.7
63.1
134.9
10.1
129.8 110.2 90.6
71.0
123.8
10.1
123.0 123.0 103.4 83.8
64.2
114.7
10.0
123.4 123.4 103.7 84.1
64.5
114.9
10.0

90
61.1
80.2
99.3
114.8
68.6
89.5
110.4
119.0
118.5
76.0
98.7
121.5
123.3
122.7
83.5
108.0
132.5
127.5
126.9
115.6
137.7
129.9
129.3
123.1
142.9
132.3
131.7
52.9
73.3
93.6
98.2
62.3
82.5
102.6
102.9
103.1
71.7
91.6
111.6
107.7
107.9
81.1
100.8
120.5
112.5
112.6
109.0
122.2
113.6
113.8
117.2
123.8
114.7
114.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
50.3
39.4
69.3
58.4
47.6
88.4
77.5
66.6
55.8
112.5 95.6
84.8
73.9
55.9
43.1
76.7
64.0
51.3
97.6
84.9
72.2
59.5
117.5 104.8 92.1
79.3
118.5 107.1 94.4
81.7
61.5
46.9
84.2
69.6
55.0
106.9 92.3
77.7
63.2
122.5 113.9 99.3
84.8
122.7 116.5 101.9 87.3
67.1
50.7
91.6
75.2
58.8
116.1 99.7
83.3
66.9
127.5 123.0 106.6 90.2
126.9 125.8 109.4 93.0
97.7
79.8
61.9
123.7 105.8 87.9
70.1
129.9 127.7 109.8 91.9
129.3 128.8 110.9 93.0
103.7 84.4
65.0
131.3 111.9 92.6
73.2
132.3 132.3 112.9 93.6
131.7 131.7 112.4 93.0
105°F
44.3
33.5
62.5
51.7
40.9
80.7
69.9
59.1
48.3
98.2
86.0
75.2
64.5
49.7
37.2
69.9
57.3
44.7
90.0
77.5
64.9
52.3
102.9 95.3
82.7
70.2
103.1 93.2
80.6
68.0
55.1
40.8
77.3
62.9
48.5
99.4
85.0
70.7
56.3
107.7 104.6 90.3
75.9
107.9 102.3 87.9
73.5
60.5
44.4
84.7
68.5
52.3
108.8 92.6
76.4
60.3
112.5 113.9 97.8
81.6
112.6 111.3 95.2
79.0
91.2
73.5
55.7
115.3 99.4
81.6
63.8
113.6 114.3 96.6
78.8
113.8 113.1 95.4
77.6
97.8
78.5
59.1
121.9 106.1 86.8
67.4
114.7 114.7 95.4
76.1
114.9 114.9 95.5
76.2

65
63.0
66.6
69.0
70.2
72.8
73.8
76.6
74.0
75.1
74.2
73.7
53.7
57.6
55.5
61.5
59.2
65.4
62.8
61.1
59.8
56.7
56.8

63

528150-YTG-T-0514
ZJ120 (10 Ton) (Continued)
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

113.0
104.5
96.0
89.7
119.6
110.6
101.6
94.9
94.9
126.1
116.6
107.2
100.1
100.1
132.7
122.7
112.7
105.3
105.3
123.4
113.3
105.9
105.9
124.0
113.9
106.5
106.4

11.0
11.0
11.0
11.0
11.1
11.1
11.1
11.0
11.0
11.2
11.2
11.2
11.1
11.0
11.3
11.3
11.3
11.2
11.1
11.2
11.2
11.2
11.1
11.2
11.2
11.2
11.1

47.0
69.2
91.4
89.7
58.6
78.6
98.5
94.9
94.9
70.2
87.9
105.6
100.1
100.1
81.8
97.3
112.7
105.3
105.3
104.9
113.3
105.9
105.9
112.5
113.9
106.5
106.4

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
40.7
30.0
101.1
12.1
58.5
47.8
37.1
93.6
12.1
76.3
65.6
55.0
44.3
86.1
12.1
89.7
79.8
69.1
58.4
47.7
81.3
12.1
46.1
33.6
108.1
12.1
66.1
53.5
41.0
100.1
12.2
86.0
73.5
61.0
48.5
92.1
12.2
94.9
89.3
76.8
64.3
51.8
87.0
12.2
94.9
85.5
73.0
60.5
47.9
86.7
12.0
51.5
37.2
115.1
12.2
73.6
59.3
44.9
106.6
12.3
95.7
81.4
67.0
52.7
98.1
12.3
100.1 98.9
84.6
70.2
55.9
92.6
12.3
100.1 94.6
80.3
66.0
51.6
92.3
12.1
56.9
40.8
122.2
12.3
81.1
65.0
48.8
113.1
12.4
105.4 89.2
73.1
56.9
104.1
12.4
105.3 108.4 92.3
76.1
60.0
98.2
12.4
105.3 103.7 87.6
71.5
55.3
98.0
12.2
87.3
69.6
52.0
113.1
12.3
109.7 95.6
78.0
60.4
104.1
12.3
105.9 107.5 89.8
72.2
54.6
98.2
12.3
105.9 105.1 87.5
69.9
52.2
98.0
12.2
93.4
74.3
55.2
113.1
12.3
113.9 102.0 82.9
63.8
104.1
12.3
106.5 106.5 87.4
68.3
49.2
98.2
12.3
106.4 106.4 87.3
68.3
49.2
98.0
12.1

90
44.1
65.1
86.1
81.3
57.2
74.7
92.1
87.0
86.7
70.3
84.2
98.1
92.6
92.3
83.4
93.7
104.1
98.2
98.0
100.8
104.1
98.2
98.0
107.8
104.1
98.2
98.0

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
37.0
26.4
54.5
43.9
33.3
72.0
61.4
50.8
40.2
81.3
74.1
63.0
52.3
42.5
30.0
62.2
49.8
37.3
82.0
69.5
57.1
44.6
87.0
83.3
70.9
58.4
86.7
77.8
65.3
52.9
47.9
33.6
69.9
55.6
41.3
92.0
77.7
63.4
49.1
92.6
92.6
78.8
64.6
92.3
87.0
72.7
58.4
53.3
37.1
77.6
61.5
45.3
102.0 85.8
69.7
53.6
98.2
98.2
86.8
70.7
98.0
96.2
80.0
63.9
83.3
65.8
48.3
104.0 91.9
74.4
56.9
98.2
98.2
83.1
65.6
98.0
97.1
79.6
62.1
89.0
70.1
51.3
104.1 97.9
79.1
60.3
98.2
98.2
79.4
60.6
98.0
98.0
79.1
60.3

65
41.7
46.0
40.4
50.3
44.1
54.5
47.8
48.1
44.6
41.7
41.5

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

64

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ150 (12.5 Ton)
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

3125

3750

4375

5000

5625

6250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

191.5
178.7
165.9
149.9
201.3
187.9
174.5
157.6
152.3
211.1
197.0
183.0
165.3
159.7
221.0
206.2
191.5
173.0
167.2
215.4
200.0
180.7
174.6
224.6
208.5
188.4
182.0

9.8
9.5
9.2
9.1
9.8
9.5
9.3
9.1
9.1
9.8
9.6
9.3
9.1
9.1
9.9
9.6
9.3
9.1
9.1
9.6
9.3
9.2
9.1
9.6
9.3
9.2
9.2

80.3
103.3
126.3
149.9
89.4
114.7
140.0
157.6
152.3
98.5
126.2
153.8
165.3
159.7
107.6
137.6
167.5
173.0
167.2
150.0
185.5
180.7
174.6
162.3
203.5
188.4
182.0

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

177.5
163.9
150.3
136.4
185.6
171.4
157.2
142.6
139.4
193.7
178.9
164.0
148.8
145.4
201.8
186.3
170.8
155.0
151.5
193.8
177.7
161.2
157.6
201.2
184.5
167.4
163.6

11.6
11.4
11.2
11.0
11.7
11.5
11.3
11.1
11.1
11.8
11.6
11.4
11.2
11.2
11.9
11.7
11.5
11.3
11.3
11.8
11.6
11.3
11.4
11.9
11.7
11.4
11.5

71.6
94.8
118.0
136.4
80.8
106.5
132.2
142.6
139.4
89.9
118.1
146.4
148.8
145.4
99.1
129.8
160.6
155.0
151.5
142.1
172.5
161.2
157.6
154.4
184.5
167.4
163.6

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
66.9
53.5
184.5
10.7
89.9
76.4
63.0
171.3
10.5
112.8 99.4
86.0
72.6
158.1
10.2
139.5 122.9 109.5 96.1
82.7
143.1
10.1
74.2
58.9
193.5
10.7
99.5
84.2
69.0
179.6
10.5
124.8 109.5 94.3
79.1
165.8
10.3
150.7 135.4 120.2 105.0 89.7
150.1
10.1
152.3 140.7 125.5 110.2 95.0
145.8
10.1
81.5
64.4
202.4
10.8
109.1 92.0
75.0
187.9
10.6
136.7 119.7 102.6 85.5
173.5
10.3
161.8 148.0 130.9 113.8 96.8
157.0
10.1
159.7 153.7 136.6 119.6 102.5
152.6
10.2
88.8
69.9
211.4
10.9
118.7 99.8
80.9
196.3
10.6
148.7 129.8 110.9 92.0
181.2
10.4
173.0 160.5 141.6 122.7 103.8
164.0
10.2
167.2 166.7 147.8 129.0 110.1
159.3
10.2
129.1 108.3 87.5
204.6
10.7
161.6 140.8 119.9 99.1
188.8
10.4
180.7 174.4 153.6 132.8 111.9
170.9
10.2
174.6 174.4 153.5 132.7 111.9
166.1
10.3
139.5 116.7 94.0
212.9
10.7
174.5 151.8 129.0 106.2
196.5
10.5
188.4 188.4 165.6 142.8 120.0
177.9
10.3
182.0 182.0 159.2 136.5 113.7
172.8
10.3
95°F
58.3
45.1
168.0
12.8
81.5
68.2
55.0
154.2
12.7
104.7 91.4
78.1
64.9
140.3
12.6
132.1 112.1 98.9
85.6
72.3
128.6
12.4
65.4
50.0
175.2
12.9
91.1
75.7
60.3
160.8
12.8
116.8 101.4 86.0
70.6
146.4
12.7
139.7 124.3 109.0 93.6
78.2
134.1
12.5
139.4 127.2 111.8 96.5
81.1
131.5
12.5
72.4
54.9
182.4
13.0
100.6 83.1
65.6
167.4
12.9
128.8 111.3 93.8
76.3
152.4
12.8
147.4 136.6 119.1 101.5 84.0
139.6
12.6
145.4 139.7 122.2 104.7 87.2
136.9
12.6
79.4
59.8
189.6
13.1
110.2 90.5
70.9
174.0
13.0
140.9 121.3 101.7 82.0
158.5
12.9
155.0 148.8 129.2 109.5 89.9
145.1
12.7
151.5 152.2 132.6 113.0 93.4
142.3
12.7
120.4 98.6
76.9
180.7
13.1
153.9 132.1 110.4 88.7
164.5
13.0
161.2 158.1 136.4 114.6 92.9
150.7
12.8
157.6 157.9 136.2 114.5 92.7
147.8
12.8
130.6 106.7 82.9
187.3
13.2
166.8 143.0 119.2 95.3
170.5
13.1
167.4 167.4 143.6 119.7 95.9
156.2
12.9
163.6 163.6 139.8 116.0 92.1
153.2
12.9

90
76.0
99.0
122.1
143.1
85.1
110.6
136.1
150.1
145.8
94.2
122.1
150.1
157.0
152.6
103.3
133.7
164.1
164.0
159.3
146.0
179.0
170.9
166.1
158.4
194.0
177.9
172.8
67.5
90.8
114.2
128.6
77.1
102.2
127.2
134.1
131.5
86.7
113.5
140.3
139.6
136.9
96.3
124.8
153.3
145.1
142.3
136.9
161.9
150.7
147.8
149.0
170.5
156.2
153.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
62.6
49.3
85.7
72.3
59.0
108.8 95.4
82.1
68.7
135.8 117.5 104.2 90.8
69.8
54.5
95.3
80.0
64.6
120.8 105.5 90.1
74.8
145.2 129.9 114.6 99.3
145.8 134.0 118.7 103.3
76.9
59.6
104.9 87.6
70.3
132.8 115.5 98.2
80.9
154.6 142.3 125.0 107.7
152.6 146.7 129.4 112.2
84.1
64.8
114.4 95.2
75.9
144.8 125.5 106.3 87.0
164.0 154.6 135.4 116.1
159.3 159.5 140.2 121.0
124.7 103.5 82.2
157.7 136.5 115.2 93.9
170.9 166.3 145.0 123.7
166.1 166.2 144.9 123.6
135.1 111.7 88.4
170.7 147.4 124.1 100.8
177.9 177.9 154.6 131.3
172.8 172.8 149.5 126.2
105°F
55.1
42.0
77.7
64.5
51.4
100.2 87.1
73.9
60.8
126.4 106.8 93.6
80.5
61.9
46.7
86.9
71.7
56.5
112.0 96.8
81.6
66.4
132.7 118.7 103.5 88.2
131.5 118.9 103.7 88.5
68.6
51.3
96.2
78.9
61.6
123.8 106.5 89.2
71.9
138.9 130.6 113.3 96.0
136.9 130.9 113.6 96.3
75.4
56.0
105.5 86.1
66.8
135.6 116.2 96.9
77.5
145.1 142.5 123.2 103.8
142.3 142.8 123.4 104.1
115.4 94.0
72.5
148.3 126.8 105.3 83.9
150.7 149.3 127.9 106.4
147.8 148.0 126.5 105.0
125.4 101.8 78.2
161.0 137.4 113.8 90.2
156.2 156.2 132.6 109.0
153.2 153.2 129.6 106.0

65
77.5
83.9
88.0
90.4
94.9
96.9
101.7
102.4
102.3
108.0
102.9
67.3
73.0
73.3
78.7
79.0
84.5
84.7
84.9
83.6
85.4
82.4

65

528150-YTG-T-0514
ZJ150 (12.5 Ton) (Continued)
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

158.4
144.4
130.4
120.7
164.8
150.2
135.6
125.6
123.7
171.1
156.0
140.8
130.4
128.4
177.5
161.8
146.1
135.3
133.2
167.6
151.3
140.1
138.0
173.4
156.5
145.0
142.7

14.0
14.0
14.0
13.8
14.1
14.1
14.1
13.9
13.9
14.2
14.2
14.2
14.0
14.0
14.4
14.3
14.3
14.1
14.1
14.4
14.4
14.2
14.2
14.5
14.5
14.3
14.3

63.3
86.9
110.4
120.7
73.4
97.9
122.3
125.6
123.7
83.5
108.8
134.2
130.4
128.4
93.6
119.8
146.1
135.3
133.2
131.7
151.3
140.1
138.0
143.6
156.5
145.0
142.7

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
51.9
38.9
148.8
15.3
73.8
60.8
47.8
134.6
15.3
95.8
82.7
69.7
56.7
120.4
15.4
120.7 101.4 88.4
75.3
62.3
112.9
15.2
58.4
43.3
154.3
15.4
82.8
67.8
52.7
139.6
15.4
107.3 92.2
77.2
62.1
124.8
15.5
125.6 113.0 98.0
82.9
67.9
117.1
15.3
123.7 110.6 95.6
80.5
65.5
115.8
15.3
64.8
47.8
159.8
15.5
91.8
74.7
57.7
144.5
15.5
118.7 101.7 84.6
67.6
129.2
15.6
130.4 124.6 107.6 90.5
73.4
121.2
15.4
128.4 122.0 104.9 87.9
70.8
119.9
15.5
71.3
52.2
165.3
15.6
100.8 81.7
62.6
149.5
15.7
130.2 111.2 92.1
73.0
133.7
15.7
135.3 136.2 117.2 98.1
79.0
125.4
15.5
133.2 133.3 114.3 95.2
76.1
124.1
15.6
110.5 89.3
68.1
154.5
15.8
142.7 121.5 100.3 79.0
138.1
15.8
140.1 140.6 119.4 98.1
76.9
129.6
15.6
138.0 138.0 116.8 95.6
74.4
128.2
15.7
120.2 96.9
73.5
159.4
15.9
155.2 131.8 108.4 85.0
142.5
15.9
145.0 145.0 121.6 98.2
74.8
133.7
15.7
142.7 142.7 119.4 96.0
72.6
132.3
15.8

90
56.6
82.9
106.6
112.9
69.8
93.6
117.4
117.1
115.8
82.9
104.2
128.1
121.2
119.9
96.0
114.8
133.7
125.4
124.1
126.5
138.1
129.6
128.2
138.2
142.5
133.7
132.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
48.7
35.8
70.0
57.1
44.2
91.3
78.4
65.5
52.6
112.9 96.0
83.1
70.2
54.9
40.0
78.7
63.8
48.9
102.5 87.6
72.7
57.9
117.1 107.3 92.5
77.6
115.8 102.3 87.4
72.5
61.1
44.2
87.4
70.5
53.7
113.7 96.9
80.0
63.2
121.2 118.6 101.8 85.0
119.9 113.1 96.3
79.4
67.2
48.5
96.1
77.3
58.5
124.9 106.1 87.3
68.5
125.4 125.4 111.1 92.4
124.1 123.9 105.1 86.3
105.6 84.6
63.6
137.1 116.1 95.2
74.2
129.6 129.6 110.9 89.9
128.2 128.1 107.1 86.1
115.1 91.9
68.8
142.5 126.2 103.0 79.9
133.7 133.7 110.6 87.4
132.3 132.3 109.1 86.0

65
57.3
62.7
57.7
68.1
62.6
73.6
67.5
68.9
65.2
64.3
62.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

66

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR037-150 Cooling and Reheat Capacities
ZR037 (3.0 Ton) Cooling
Air on
Evaporator Coil
CFM

750

900

1050

1200

1350

1500

750

900

1050

1200

1350

1500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

48.2
43.9
39.6
35.5
50.4
45.9
41.4
37.1
33.3
52.7
47.9
43.2
38.7
34.7
54.9
50.0
45.1
40.4
36.2
50.0
45.0
40.4
36.2
49.9
45.0
40.3
36.2

0.2
0.8
1.3
1.1
0.5
1.1
1.6
1.4
1.3
0.8
1.3
1.9
1.7
1.6
1.0
1.6
2.2
2.0
1.8
1.4
2.0
1.8
1.6
1.2
1.8
1.6
1.5

20.1
24.6
29.0
35.5
22.1
27.8
33.4
37.1
33.3
24.1
31.0
37.8
38.7
34.7
26.1
34.2
42.2
40.4
36.2
36.8
43.6
40.4
36.2
39.3
45.0
40.3
36.2

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

38.8
35.6
32.5
27.3
40.5
37.2
33.9
28.5
26.2
42.2
38.7
35.3
29.7
27.2
43.9
40.3
36.7
30.8
28.3
40.1
36.5
30.7
28.2
40.0
36.4
30.6
28.1

3.1
2.8
2.6
2.7
3.0
2.7
2.5
2.7
2.4
2.8
2.6
2.4
2.6
2.3
2.7
2.5
2.3
2.5
2.2
2.5
2.3
2.5
2.2
2.5
2.3
2.5
2.2

13.9
19.9
25.9
27.3
17.2
23.4
29.5
28.5
26.2
20.6
26.8
33.1
29.7
27.2
23.9
30.3
36.7
30.8
28.3
32.4
36.5
30.7
28.2
34.4
36.4
30.6
28.1

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
16.2
13.0
43.5
1.6
21.3
18.1
14.9
39.8
1.8
26.5
23.3
20.1
16.8
36.0
2.0
32.6
28.4
25.1
21.9
18.7
31.4
1.9
18.2
14.3
45.5
1.7
23.9
20.0
16.1
41.6
1.9
29.5
25.6
21.7
17.8
37.6
2.1
35.2
31.3
27.4
23.5
19.6
32.8
2.0
33.4
30.5
26.6
22.7
18.8
29.7
1.9
20.3
15.7
47.4
1.8
26.4
21.8
17.2
43.3
2.0
32.5
27.9
23.4
18.8
39.2
2.1
37.8
34.2
29.6
25.0
20.5
34.2
2.1
34.8
33.3
28.8
24.2
19.6
31.0
1.9
22.3
17.0
49.4
1.9
28.9
23.6
18.4
45.1
2.1
35.5
30.3
25.0
19.8
40.9
2.2
40.4
37.1
31.8
26.6
21.3
35.6
2.2
36.2
36.2
30.9
25.7
20.4
32.3
2.0
31.0
25.2
19.5
45.0
2.0
38.2
32.3
26.6
20.8
40.8
2.1
40.4
38.7
33.0
27.2
21.5
35.5
2.1
36.2
36.2
30.4
24.7
18.9
32.2
1.9
33.1
26.8
20.6
45.0
1.9
40.9
34.4
28.2
21.9
40.7
2.1
40.3
40.3
34.1
27.8
21.6
35.5
2.0
36.2
36.2
29.9
23.7
17.4
32.1
1.9
95°F
11.6
8.5
36.4
2.7
16.9
13.8
10.8
32.8
2.7
22.2
19.1
16.1
13.0
29.2
2.6
26.6
21.0
18.0
14.9
11.9
25.0
2.6
13.5
9.8
37.5
2.7
19.7
16.0
12.3
33.8
2.7
25.8
22.1
18.4
14.7
30.1
2.6
28.0
24.3
20.6
16.9
13.2
25.8
2.6
26.0
22.3
18.6
14.9
11.2
24.9
2.4
15.5
11.2
38.6
2.7
22.5
18.1
13.8
34.8
2.7
29.4
25.1
20.7
16.4
31.0
2.6
29.4
27.6
23.2
18.9
14.5
26.5
2.6
27.2
25.3
21.0
16.6
12.3
25.6
2.5
17.5
12.5
39.7
2.7
25.3
20.3
15.3
35.8
2.7
33.1
28.1
23.1
18.1
31.9
2.6
30.8
30.8
25.8
20.8
15.8
27.3
2.6
28.3
28.3
23.3
18.3
13.3
26.4
2.5
26.7
21.1
15.5
35.8
2.6
34.7
29.2
23.6
17.9
31.9
2.6
30.7
30.7
25.1
19.5
13.8
27.3
2.5
28.2
28.2
22.6
17.0
11.3
26.4
2.4
28.2
21.9
15.6
35.8
2.6
36.4
30.3
24.1
17.8
31.9
2.5
30.6
30.6
24.3
18.1
11.8
27.3
2.5
28.1
28.1
21.8
15.6
9.3
26.4
2.4

90
17.0
22.2
27.5
31.4
19.7
25.6
31.5
32.8
29.7
22.3
28.9
35.4
34.2
31.0
25.0
32.2
39.4
35.6
32.3
34.6
40.1
35.5
32.2
36.9
40.7
35.5
32.1
12.7
19.0
25.3
25.0
16.5
22.0
27.5
25.8
24.9
20.4
25.0
29.7
26.5
25.6
24.2
28.0
31.9
27.3
26.4
30.4
31.9
27.3
26.4
32.7
31.9
27.3
26.4

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
13.9
10.7
19.1
16.0
12.8
24.3
21.2
18.1
14.9
29.6
24.7
21.6
18.4
15.9
12.1
21.8
18.0
14.2
27.7
23.9
20.1
16.3
31.6
27.8
24.0
20.2
29.7
26.4
22.6
18.8
17.9
13.4
24.4
20.0
15.5
31.0
26.5
22.1
17.6
33.6
30.9
26.4
21.9
31.0
29.3
24.9
20.4
19.9
14.8
27.1
22.0
16.8
34.3
29.2
24.0
18.9
35.6
34.0
28.8
23.7
32.3
32.3
27.1
22.0
28.9
23.2
17.5
36.5
30.8
25.1
19.4
35.5
34.7
29.0
23.3
32.2
32.2
26.5
20.8
30.6
24.4
18.1
38.6
32.4
26.1
19.9
35.5
35.5
29.2
23.0
32.1
32.1
25.9
19.6
105°F
11.2
8.3
16.1
13.1
10.2
20.9
17.9
15.0
12.1
24.7
19.5
16.5
13.6
13.0
9.4
18.4
14.9
11.3
23.9
20.3
16.8
13.2
25.5
22.1
18.5
14.9
24.9
21.4
17.8
14.2
14.7
10.5
20.8
16.6
12.4
26.9
22.7
18.5
14.3
26.4
24.7
20.5
16.3
25.6
23.9
19.6
15.4
16.4
11.6
23.2
18.4
13.5
30.0
25.1
20.3
15.4
27.3
27.3
22.5
17.6
26.4
26.4
21.5
16.7
24.9
19.5
14.0
30.9
26.7
21.2
15.7
27.3
27.3
21.9
16.4
26.4
26.4
20.9
15.5
26.7
20.6
14.5
31.9
28.2
22.1
16.0
27.3
27.3
21.2
15.2
26.4
26.4
20.3
14.2

65
15.3
16.4
15.0
17.5
15.9
18.6
16.9
17.6
15.1
16.7
13.4
10.7
11.4
10.6
12.1
11.2
12.8
11.8
10.9
10.0
9.1
8.2

67

528150-YTG-T-0514
ZR037 (3.0 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

750

900

1050

1200

1350

1500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

34.0
30.0
26.0
22.8
34.5
30.4
26.4
23.1
23.7
35.0
30.9
26.8
23.4
24.0
35.4
31.3
27.2
23.8
24.4
31.5
27.3
23.9
24.5
31.6
27.4
24.0
24.6

2.4
2.5
2.6
2.4
2.5
2.6
2.7
2.5
2.5
2.6
2.7
2.8
2.6
2.6
2.7
2.8
2.9
2.7
2.7
2.7
2.9
2.6
2.6
2.7
2.8
2.5
2.5

11.6
18.1
24.6
22.8
15.9
20.7
25.5
23.1
23.7
20.1
23.2
26.3
23.4
24.0
24.4
25.8
27.2
23.8
24.4
28.4
27.3
23.9
24.5
31.1
27.4
24.0
24.6

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
10.9
8.1
31.5
2.1
15.3
12.4
9.6
27.2
2.3
19.6
16.8
13.9
11.1
22.8
2.6
22.8
18.0
15.1
12.3
9.5
20.5
2.2
12.4
9.0
31.4
2.3
17.2
13.8
10.3
27.1
2.5
22.0
18.6
15.1
11.7
22.7
2.8
23.1
19.9
16.5
13.0
9.6
20.4
2.4
23.7
20.4
17.0
13.5
10.1
22.5
2.5
13.9
9.8
31.3
2.5
19.2
15.1
11.0
26.9
2.8
24.4
20.4
16.3
12.2
22.6
3.0
23.4
21.8
17.8
13.7
9.6
20.3
2.6
24.0
22.4
18.3
14.3
10.2
22.5
2.7
15.4
10.7
31.2
2.7
21.1
16.4
11.8
26.8
3.0
26.9
22.2
17.5
12.8
22.4
3.3
23.8
23.8
19.1
14.4
9.7
20.2
2.8
24.4
24.4
19.7
15.0
10.3
22.4
2.9
23.1
17.9
12.6
27.1
2.9
27.1
24.1
18.8
13.6
22.7
3.1
23.9
23.9
18.6
13.3
8.1
20.5
2.7
24.5
24.5
19.2
14.0
8.7
22.7
2.8
25.2
19.3
13.4
27.4
2.7
27.4
26.0
20.2
14.3
23.0
3.0
24.0
24.0
18.1
12.3
6.4
20.7
2.6
24.6
24.6
18.8
12.9
7.0
22.9
2.7

90
11.5
17.2
22.8
20.5
15.9
19.3
22.7
20.4
22.5
20.3
21.4
22.6
20.3
22.5
24.7
23.6
22.4
20.2
22.4
26.5
22.7
20.5
22.7
27.4
23.0
20.7
22.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
9.9
7.9
14.5
11.7
9.0
18.3
15.6
12.9
10.1
20.5
16.5
13.7
11.0
11.8
8.5
16.0
12.7
9.3
20.1
16.8
13.5
10.2
20.4
17.7
14.4
11.1
22.5
19.5
16.2
12.8
13.7
9.2
17.5
13.6
9.7
21.9
18.0
14.1
10.2
20.3
19.0
15.0
11.1
22.5
21.0
17.0
13.1
15.6
9.8
19.0
14.5
10.0
22.4
19.2
14.7
10.2
20.2
20.2
15.7
11.2
22.4
22.4
17.9
13.4
21.4
16.3
11.2
22.7
21.6
16.5
11.4
20.5
20.5
15.4
10.3
22.7
22.7
17.6
12.5
23.7
18.0
12.3
23.0
23.0
18.2
12.6
20.7
20.7
15.0
9.3
22.9
22.9
17.2
11.5

65
8.3
7.7
9.5
7.2
9.2
6.7
8.9
5.2
7.4
3.7
5.9

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

68

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR037 (3.0 Ton) Reheat
Air on
Evaporator Coil
CFM

Total
Capacity1
(MBh)

Total
Input
(kW)2

62.5
64
65.3
62.5
64
65.3
62.5
64
65.3

14.1
15.3
17.0
14.9
15.6
16.1
21.7
22.3
22.5

1.3
1.3
1.4
1.3
1.3
1.3
1.9
1.9
1.8

62.5
64
65.3
62.5
64
65.3
62.5
64
62

18.5
19.7
20.9
19.2
20.3
22.2
19.8
21.1
22.3

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

62.5
64
65.3
62.5
64
65.3
62.5
64
65.3

16.3
17.6
18.8
16.6
18.0
18.9
15.8
17.3
18.5

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

62.5
64
65.3
62.5
64
65.3
62.5
64
62

12.0
12.5
13.4
11.8
12.9
13.9
11.7
12.6
13.6

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

WB
(°F)

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
(- indicates heating)
Capacity1
Return Dry Bulb (°F)
(MBh)
75
40 °F

1050

1200

1350

50 °F
8.9
8.1
7.1
9.7
8.7
7.8
11.1
9.3
8.0

19.7
21.3
22.5
20.3
21.2
23.1
21.6
23.1
24.7

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

8.1
6.6
5.4
9.0
7.6
6.3
9.8
8.4
7.2

17.0
18.4
19.6
17.0
18.5
19.9
16.1
17.3
18.8

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

7.2
5.5
4.0
7.4
6.1
5.0
7.8
6.7
5.2

15.0
16.2
16.6
14.9
16.1
17.2
14.4
15.6
16.7

2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1

4.5
3.1
1.9
5.0
3.7
2.3
5.6
4.0
2.7

7.5
8.5
9.3
8.8
8.0
8.2
6.0
6.7
7.7

2.3
2.3
2.4
2.3
2.3
2.4
2.3
2.3
2.3

60 °F
1050

1200

1350

1200

1350

1200

1350

6.8
5.5
4.4
7.9
6.6
5.5
8.4
6.8
5.7
80 °F

85 °F
1050

8.9
7.5
6.2
9.8
8.3
7.1
10.9
9.7
8.2
70 °F

75 °F
1050

Sensible Capacity (MBh)
(- indicates heating)
Return Dry Bulb (°F)
75

Total
Input
(kW)2

5.9
4.5
3.6
6.7
5.5
3.9
7.1
5.8
4.4
95 °F
1.7
0.5
-0.9
-0.6
0.6
-0.9
1.9
0.6
-0.7

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

69

528150-YTG-T-0514

ZR049 (4.0 Ton) Cooling
Air on
Evaporator Coil
CFM

1000

1200

1400

1600

1800

2000

1000

1200

1400

1600

1800

2000

70

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

70.8
62.1
53.5
48.3
73.1
64.2
55.3
50.0
48.7
75.5
66.3
57.1
51.6
50.2
77.9
68.4
58.9
53.2
51.8
70.3
60.5
54.7
53.2
72.1
62.1
56.1
54.7

1.6
2.0
2.4
2.0
1.8
2.2
2.6
2.2
2.2
2.1
2.4
2.8
2.4
2.4
2.3
2.6
3.0
2.6
2.6
2.4
2.8
2.4
2.4
2.2
2.6
2.2
2.2

27.3
34.1
40.8
48.3
30.4
37.7
45.1
50.0
48.7
33.4
41.4
49.4
51.6
50.2
36.5
45.1
53.7
53.2
51.8
48.1
57.9
54.7
53.2
51.0
62.1
56.1
54.7

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

52.2
47.9
43.6
37.9
54.4
49.9
45.4
39.5
39.6
56.6
51.9
47.3
41.1
41.2
58.8
54.0
49.1
42.7
42.8
54.1
49.2
42.7
42.8
54.2
49.3
42.8
42.9

4.4
3.9
3.4
3.9
4.2
3.7
3.2
3.6
3.6
4.0
3.5
3.0
3.4
3.4
3.7
3.3
2.9
3.2
3.2
3.5
3.1
3.4
3.4
3.7
3.3
3.7
3.7

24.8
30.5
36.3
37.9
27.7
33.9
40.1
39.5
39.6
30.5
37.3
44.0
41.1
41.2
33.4
40.7
47.9
42.7
42.8
44.1
48.6
42.7
42.8
47.5
49.3
42.8
42.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
22.8
18.2
61.5
3.0
29.5
24.9
20.3
55.0
3.0
36.2
31.6
27.0
22.4
48.5
2.9
46.8
37.7
33.1
28.5
23.9
43.1
2.9
25.1
19.9
63.8
3.0
32.5
27.3
22.0
57.1
3.0
39.9
34.6
29.4
24.2
50.3
2.9
48.9
41.3
36.1
30.9
25.6
44.7
2.9
48.7
44.1
38.9
33.7
28.4
44.1
2.9
27.5
21.6
66.1
3.0
35.5
29.6
23.8
59.1
3.0
43.5
37.6
31.8
25.9
52.2
2.9
51.1
44.9
39.0
33.1
27.3
46.3
2.9
50.2
48.0
42.1
36.2
30.3
45.7
2.9
29.9
23.4
68.4
3.0
38.6
32.0
25.5
61.2
3.0
47.2
40.7
34.1
27.6
54.0
2.9
53.2
48.5
42.0
35.4
28.9
47.9
2.9
51.8
51.8
45.3
38.7
32.2
47.3
2.9
40.9
33.7
26.6
62.2
3.0
50.0
42.8
35.7
28.5
54.8
2.9
54.7
52.3
45.1
38.0
30.8
48.7
2.9
53.2
53.2
46.1
38.9
31.7
48.0
2.9
43.2
35.4
27.7
63.1
3.0
52.8
45.0
37.2
29.4
55.7
2.9
56.1
56.1
48.3
40.5
32.7
49.5
2.9
54.7
54.7
46.9
39.1
31.3
48.8
2.9
95°F
20.5
16.1
51.3
4.2
26.2
21.9
17.6
45.4
3.9
31.9
27.6
23.3
19.0
39.6
3.6
37.9
33.9
29.5
25.2
20.9
34.1
3.8
22.6
17.5
52.8
4.1
28.8
23.8
18.7
46.8
3.8
35.1
30.0
25.0
19.9
40.8
3.5
39.5
36.8
31.7
26.7
21.6
35.1
3.7
39.6
36.9
31.8
26.8
21.7
35.7
3.7
24.7
18.9
54.3
4.0
31.5
25.7
19.9
48.2
3.7
38.2
32.4
26.6
20.8
42.0
3.4
41.1
39.7
33.9
28.1
22.3
36.2
3.6
41.2
39.8
34.0
28.2
22.4
36.8
3.6
26.9
20.3
55.8
3.9
34.1
27.6
21.0
49.5
3.6
41.3
34.8
28.3
21.7
43.2
3.4
42.7
42.7
36.1
29.6
23.1
37.2
3.5
42.8
42.8
36.2
29.7
23.1
37.9
3.5
36.9
29.7
22.5
49.9
3.7
44.7
37.5
30.3
23.1
43.5
3.5
42.7
42.7
35.5
28.4
21.2
37.5
3.6
42.8
42.8
35.6
28.4
21.3
38.1
3.6
39.7
31.8
24.0
50.3
3.9
48.0
40.2
32.3
24.5
43.8
3.6
42.8
42.8
35.0
27.1
19.3
37.8
3.7
42.9
42.9
35.1
27.2
19.4
38.4
3.7

90
26.1
32.3
38.5
43.1
29.0
35.8
42.6
44.7
44.1
32.0
39.3
46.7
46.3
45.7
34.9
42.9
50.8
47.9
47.3
46.1
53.3
48.7
48.0
49.3
55.7
49.5
48.8
21.3
28.4
35.5
34.1
25.3
31.6
37.8
35.1
35.7
29.4
34.8
40.2
36.2
36.8
33.5
38.0
42.6
37.2
37.9
41.5
43.2
37.5
38.1
44.9
43.8
37.8
38.4

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
21.6
17.2
27.8
23.4
18.9
34.1
29.6
25.2
20.7
42.3
35.8
31.3
26.9
23.9
18.7
30.7
25.5
20.4
37.5
32.3
27.2
22.0
44.2
39.1
33.9
28.8
44.1
40.5
35.4
30.2
26.1
20.3
33.5
27.7
21.8
40.9
35.0
29.2
23.3
46.1
42.3
36.5
30.6
45.7
43.9
38.1
32.2
28.4
21.9
36.3
29.8
23.3
44.3
37.7
31.2
24.7
47.9
45.6
39.1
32.5
47.3
47.3
40.7
34.2
38.9
31.7
24.5
47.3
40.2
33.0
25.8
48.7
47.5
40.3
33.2
48.0
48.0
40.9
33.7
41.5
33.6
25.8
50.4
42.6
34.8
27.0
49.5
49.5
41.6
33.8
48.8
48.8
41.0
33.1
105°F
18.4
14.1
24.1
19.9
15.6
29.8
25.6
21.3
17.1
34.1
29.2
25.0
20.7
20.4
15.4
26.6
21.7
16.7
32.9
27.9
22.9
18.0
35.1
31.9
26.9
22.0
35.7
32.4
27.5
22.5
22.4
16.7
29.1
23.5
17.8
35.9
30.2
24.6
18.9
36.2
34.6
28.9
23.2
36.8
35.1
29.5
23.8
24.4
18.0
31.7
25.3
18.9
39.0
32.6
26.2
19.8
37.2
37.2
30.8
24.5
37.9
37.9
31.5
25.1
34.4
27.3
20.3
41.1
35.2
28.1
21.1
37.5
37.5
30.4
23.4
38.1
38.1
31.1
24.0
37.1
29.4
21.6
43.2
37.9
30.1
22.4
37.8
37.8
30.0
22.3
38.4
38.4
30.7
22.9

65
22.4
23.6
25.1
24.8
26.4
26.0
27.7
26.0
26.5
26.0
25.3
16.5
17.0
17.6
17.5
18.1
18.1
18.7
16.3
16.9
14.5
15.2

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR049 (4.0 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

1000

1200

1400

1600

1800

2000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

50.4
43.0
35.6
30.3
51.2
43.7
36.1
30.8
31.9
52.0
44.4
36.7
31.3
32.4
52.9
45.1
37.3
31.8
32.9
45.7
37.8
32.2
33.5
46.4
38.4
32.7
34.0

4.0
3.9
3.8
3.7
4.0
3.9
3.8
3.7
3.8
4.0
3.9
3.8
3.7
3.8
4.0
3.9
3.8
3.8
3.8
3.9
3.9
3.8
3.8
4.0
3.9
3.8
3.8

17.7
26.2
34.6
30.3
23.0
29.3
35.5
30.8
31.9
28.3
32.3
36.4
31.3
32.4
33.6
35.4
37.3
31.8
32.9
38.8
37.8
32.2
33.5
42.2
38.4
32.7
34.0

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
16.3
12.1
49.5
3.7
22.0
17.8
13.6
40.5
3.9
27.7
23.5
19.3
15.2
31.5
4.0
30.3
24.6
20.5
16.3
12.1
26.5
3.6
18.1
13.3
49.6
3.9
24.4
19.5
14.7
40.6
4.0
30.7
25.8
20.9
16.1
31.5
4.1
30.8
27.0
22.1
17.3
12.4
26.5
3.8
31.9
28.0
23.2
18.3
13.4
28.1
3.8
20.0
14.5
49.7
4.0
26.8
21.3
15.7
40.6
4.1
33.6
28.1
22.5
17.0
31.4
4.2
31.3
29.4
23.8
18.3
12.8
26.4
3.9
32.4
30.5
24.9
19.4
13.8
28.1
3.9
21.9
15.6
49.9
4.2
29.2
23.0
16.8
40.6
4.3
36.6
30.3
24.1
17.9
31.3
4.3
31.8
31.8
25.5
19.3
13.1
26.3
4.0
32.9
32.9
26.7
20.5
14.3
28.0
4.1
31.9
24.9
18.0
41.6
4.2
37.5
32.9
26.0
19.0
32.2
4.3
32.2
32.2
25.3
18.4
11.4
27.0
3.9
33.5
33.5
26.5
19.6
12.6
28.8
4.0
34.6
26.9
19.3
42.6
4.1
38.4
35.5
27.9
20.2
33.0
4.2
32.7
32.7
25.1
17.4
9.8
27.7
3.8
34.0
34.0
26.3
18.6
11.0
29.5
3.9

90
16.5
24.0
31.5
26.5
22.4
26.9
31.5
26.5
28.1
28.4
29.9
31.4
26.4
28.1
34.3
32.8
31.3
26.3
28.0
36.2
32.2
27.0
28.8
39.5
33.0
27.7
29.5

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
12.8
10.1
19.9
15.8
11.7
25.6
21.5
17.4
13.3
26.5
20.0
15.9
11.8
15.9
11.2
22.2
17.4
12.7
28.4
23.7
18.9
14.2
26.5
22.1
17.4
12.6
28.1
23.6
18.8
14.1
19.0
12.2
24.5
19.0
13.6
31.3
25.9
20.5
15.1
26.4
24.2
18.8
13.4
28.1
25.8
20.4
15.0
22.2
13.3
26.8
20.7
14.6
31.3
28.1
22.0
15.9
26.3
26.3
20.2
14.2
28.0
28.0
22.0
15.9
29.4
22.6
15.7
32.2
30.6
23.8
17.0
27.0
27.0
20.2
13.4
28.8
28.8
21.9
15.1
32.0
24.4
16.9
33.0
33.0
25.6
18.1
27.7
27.7
20.1
12.6
29.5
29.5
21.9
14.4

65
7.7
7.8
9.3
8.0
9.6
8.1
9.8
6.6
8.3
5.0
6.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

71

528150-YTG-T-0514

ZR049 (4.0 Ton) Reheat
Air on
Evaporator Coil
CFM

Total
Capacity1
(MBh)

Total
Input
(kW)2

62.5
64
65.3
62.5
64
65.3
62.5
64
65.3

24.5
25.7
26.6
24.0
25.8
27.1
24.3
26.2
27.1

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

62.5
64
65.3
62.5
64
65.3
62.5
64
62

21.8
25.3
26.9
22.7
25.4
26.9
20.1
22.3
23.7

2.6
2.7
2.7
2.7
2.7
2.7
2.6
2.6
2.6

62.5
64
65.3
62.5
64
65.3
62.5
64
65.3

19.0
21.5
22.2
19.3
21.3
22.6
16.9
18.2
19.9

2.7
2.8
2.8
2.8
2.8
2.8
2.7
2.7
2.8

62.5
64
65.3
62.5
64
65.3
62.5
64
62

17.7
19.0
20.4
16.2
18.2
19.6
13.3
14.8
15.8

2.9
2.9
2.9
2.9
3.0
3.0
2.9
2.9
2.9

WB
(°F)

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
(- indicates heating)
Capacity1
Return Dry Bulb (°F)
(MBh)
75
40 °F

1200

1600

2000

50 °F
9.1
7.4
6.1
12.4
10.0
8.3
12.9
11.1
9.2

22.9
26.9
27.1
24.5
26.7
28.5
22.7
24.7
26.5

2.6
2.7
2.6
2.6
2.6
2.6
2.6
2.6
2.6

7.1
6.3
4.8
9.9
8.8
7.5
10.2
8.6
6.9

19.8
23.0
23.5
20.6
22.4
24.4
18.2
20.5
21.4

2.7
2.8
2.7
2.7
2.8
2.8
2.7
2.7
2.7

5.5
5.1
2.8
8.1
6.3
4.7
7.9
6.3
4.8

17.6
20.9
21.5
17.9
19.9
21.1
15.1
16.7
18.3

2.8
2.9
2.9
2.9
2.9
2.9
2.8
2.8
2.8

5.0
3.4
2.1
6.4
5.0
3.1
6.6
4.7
3.1

12.8
13.8
14.0
9.7
10.8
12.2
6.2
7.2
8.0

3.1
3.2
3.1
3.1
3.2
3.2
3.0
3.0
3.0

60 °F
1200

1600

2000

1600

2000

1600

2000

6.2
0.0
2.9
8.8
6.8
5.9
8.9
7.7
5.3
80 °F

85 °F
1200

8.0
7.2
5.5
11.2
9.2
7.7
11.6
10.0
8.5
70 °F

75 °F
1200

Sensible Capacity (MBh)
(- indicates heating)
Return Dry Bulb (°F)
75

Total
Input
(kW)2

4.7
3.7
2.3
7.5
5.7
4.1
7.1
5.6
4.0
95 °F
3.5
-0.2
-1.5
2.4
1.0
-0.7
1.4
-0.1
-1.5

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

72

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR061 (5.0 Ton) Cooling
Air on
Evaporator Coil
CFM

1250

1500

1750

2000

2250

2500

1250

1500

1750

2000

2250

2500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

81.7
72.8
64.0
57.0
85.0
75.8
66.6
59.3
58.1
88.3
78.7
69.2
61.6
60.4
91.6
81.7
71.8
63.9
62.6
82.5
72.5
64.5
63.3
83.4
73.2
65.2
63.9

5.9
5.0
4.0
3.6
5.4
4.5
3.6
3.2
4.1
4.9
4.1
3.2
2.8
3.7
4.4
3.6
2.8
2.5
3.2
3.9
3.0
2.6
3.5
4.2
3.3
2.8
3.7

33.6
41.9
50.2
57.0
37.9
47.1
56.4
59.3
58.1
42.1
52.3
62.5
61.6
60.4
46.3
57.5
68.6
63.9
62.6
60.8
70.9
64.5
63.3
64.2
73.2
65.2
63.9

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

70.7
62.8
54.8
48.1
73.1
64.9
56.7
49.7
49.7
75.5
67.0
58.5
51.3
51.3
77.9
69.1
60.4
52.9
52.9
69.3
60.5
53.0
53.1
69.4
60.7
53.2
53.2

3.7
3.7
3.7
4.0
3.8
3.7
3.7
4.0
4.0
3.8
3.7
3.7
4.0
4.0
3.8
3.8
3.7
4.0
4.1
3.9
3.9
4.3
4.3
4.1
4.1
4.5
4.5

30.8
38.2
45.5
48.1
34.5
42.5
50.5
49.7
49.7
38.2
46.8
55.4
51.3
51.3
41.8
51.1
60.4
52.9
52.9
55.0
60.5
53.0
53.1
58.9
60.7
53.2
53.2

Johnson Controls Unitary Products

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
27.7
21.9
76.2
4.8
36.1
30.2
24.3
67.8
4.3
44.4
38.5
32.6
26.7
59.4
3.8
57.0
45.7
39.9
33.9
28.1
52.5
3.8
31.1
24.3
79.0
4.6
40.4
33.6
26.8
70.3
4.1
49.6
42.9
36.1
29.3
61.6
3.7
59.3
50.9
44.1
37.4
30.6
54.5
3.6
58.1
52.1
45.3
38.6
31.8
53.9
4.1
34.4
26.8
81.9
4.3
44.6
37.0
29.4
72.9
3.9
54.8
47.2
39.5
31.9
63.9
3.5
61.6
56.0
48.4
40.7
33.1
56.4
3.4
60.4
57.3
49.7
42.1
34.4
55.8
3.9
37.8
29.3
84.7
4.1
48.9
40.4
31.9
75.4
3.7
60.1
51.5
43.0
34.5
66.1
3.3
63.9
61.2
52.7
44.1
35.6
58.4
3.2
62.6
62.6
54.1
45.6
37.0
57.8
3.6
51.6
42.4
33.2
75.9
3.9
63.3
54.1
44.9
35.8
66.5
3.5
64.5
63.2
54.0
44.8
35.6
58.8
3.5
63.3
63.3
54.1
44.9
35.7
58.2
3.9
54.3
44.5
34.6
76.4
4.1
66.6
56.7
46.9
37.1
66.9
3.7
65.2
65.2
55.3
45.5
35.6
59.2
3.7
63.9
63.9
54.0
44.2
34.4
58.5
4.1
95°F
25.3
19.7
65.8
4.9
32.6
27.0
21.5
57.8
4.6
39.9
34.3
28.8
23.2
49.8
4.3
48.1
41.4
35.8
30.3
24.7
43.0
4.6
28.0
21.6
67.2
4.8
36.0
29.5
23.1
59.0
4.5
44.0
37.5
31.1
24.6
50.8
4.3
49.7
45.2
38.8
32.3
25.8
43.9
4.6
49.7
45.3
38.8
32.3
25.9
44.9
4.6
30.8
23.4
68.6
4.7
39.4
32.1
24.7
60.3
4.5
48.1
40.7
33.3
26.0
51.9
4.2
51.3
49.1
41.7
34.3
27.0
44.9
4.5
51.3
49.1
41.7
34.4
27.0
45.9
4.5
33.5
25.2
70.0
4.7
42.8
34.6
26.3
61.5
4.4
52.2
43.9
35.6
27.3
53.0
4.1
52.9
52.9
44.6
36.4
28.1
45.8
4.4
52.9
52.9
44.7
36.4
28.1
46.8
4.4
46.0
37.0
27.9
61.6
4.6
56.0
46.9
37.9
28.9
53.1
4.3
53.0
53.0
44.0
35.0
25.9
45.9
4.6
53.1
53.1
44.0
35.0
26.0
46.9
4.7
49.1
39.4
29.6
61.6
4.8
59.8
50.0
40.2
30.4
53.1
4.5
53.2
53.2
43.4
33.6
23.8
45.9
4.8
53.2
53.2
43.4
33.6
23.8
46.9
4.9

90
32.2
40.1
47.9
52.5
36.2
44.8
53.4
54.5
53.9
40.1
49.5
59.0
56.4
55.8
44.0
54.3
64.5
58.4
57.8
57.9
65.7
58.8
58.2
61.6
66.9
59.2
58.5
25.3
35.2
45.1
43.0
31.0
39.4
47.7
43.9
44.9
36.8
43.6
50.4
44.9
45.9
42.5
47.8
53.0
45.8
46.8
51.5
53.1
45.9
46.9
55.3
53.1
45.9
46.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
26.5
20.8
34.3
28.6
22.9
42.1
36.4
30.7
25.0
52.5
43.6
37.8
32.1
29.6
23.0
38.2
31.6
25.0
46.8
40.2
33.6
27.0
54.5
48.1
41.4
34.8
53.9
48.7
42.1
35.4
32.6
25.1
42.0
34.5
27.0
51.5
43.9
36.4
28.9
56.4
52.5
45.0
37.5
55.8
53.2
45.7
38.2
35.6
27.2
45.9
37.5
29.1
56.1
47.7
39.3
30.9
58.4
57.0
48.6
40.2
57.8
57.8
49.4
41.0
48.8
39.7
30.6
59.6
50.5
41.4
32.3
58.8
58.1
49.0
39.9
58.2
58.2
49.1
39.9
51.7
41.9
32.1
63.2
53.4
43.5
33.7
59.2
59.2
49.3
39.5
58.5
58.5
48.7
38.9
105°F
21.7
16.5
29.7
24.3
18.9
37.8
32.1
26.6
21.2
43.0
35.7
30.3
24.8
24.5
18.1
33.0
26.6
20.2
41.5
35.1
28.7
22.3
43.9
39.1
32.7
26.3
44.9
39.9
33.5
27.1
27.3
19.7
36.2
28.9
21.6
45.2
38.1
30.8
23.5
44.9
42.5
35.1
27.8
45.9
43.4
36.0
28.7
30.0
21.2
39.5
31.2
22.9
48.9
41.2
32.9
24.6
45.8
45.8
37.5
29.2
46.8
46.8
38.5
30.3
42.5
33.4
24.3
50.8
44.1
35.0
26.0
45.9
45.9
36.8
27.7
46.9
46.9
37.8
28.7
45.5
35.6
25.8
52.7
47.0
37.2
27.3
45.9
45.9
36.1
26.2
46.9
46.9
37.1
27.2

65
26.4
28.2
28.8
30.0
30.7
31.8
32.6
30.8
30.8
29.7
29.1
19.4
19.9
20.8
20.4
21.4
21.0
22.0
18.7
19.7
16.4
17.4

73

528150-YTG-T-0514
ZR061 (5.0 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

1250

1500

1750

2000

2250

2500

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

60.8
52.8
44.7
37.9
61.3
53.2
45.0
38.2
40.1
61.7
53.5
45.3
38.5
40.4
62.2
53.9
45.7
38.8
40.7
53.9
45.6
38.7
40.7
53.8
45.6
38.7
40.6

6.1
5.6
5.0
5.3
5.9
5.4
4.8
5.1
5.2
5.7
5.2
4.7
4.9
5.0
5.5
5.0
4.5
4.8
4.8
5.2
4.7
5.0
5.1
5.5
4.9
5.2
5.3

19.8
32.2
44.7
37.9
27.6
36.3
45.0
38.2
40.1
35.4
40.4
45.3
38.5
40.4
43.2
44.4
45.7
38.8
40.7
48.1
45.6
38.7
40.7
51.7
45.6
38.7
40.6

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
18.1
13.3
55.9
7.3
26.9
21.6
16.2
47.8
6.5
35.7
29.8
24.5
19.1
39.6
5.7
37.9
30.0
24.7
19.4
14.0
32.9
5.9
20.9
14.6
55.4
7.0
30.0
23.6
17.3
47.3
6.2
39.0
32.7
26.4
20.0
39.2
5.4
38.2
32.9
26.6
20.3
14.0
32.5
5.7
40.1
34.6
28.3
22.0
15.6
35.4
5.8
23.8
15.9
54.8
6.7
33.1
25.7
18.4
46.8
5.9
42.3
35.6
28.3
20.9
38.8
5.2
38.5
35.8
28.5
21.2
13.9
32.1
5.4
40.4
37.7
30.3
23.0
15.7
35.0
5.5
26.6
17.2
54.3
6.4
36.1
27.8
19.5
46.3
5.7
45.7
38.5
30.1
21.8
38.3
4.9
38.8
38.8
30.4
22.1
13.8
31.7
5.1
40.7
40.7
32.4
24.1
15.8
34.6
5.2
38.9
29.8
20.7
46.2
5.9
45.6
41.2
32.1
23.0
38.2
5.1
38.7
38.7
29.6
20.5
11.4
31.6
5.4
40.7
40.7
31.6
22.5
13.4
34.5
5.5
41.8
31.9
22.0
46.0
6.1
45.6
44.0
34.1
24.2
38.1
5.3
38.7
38.7
28.8
18.9
9.0
31.5
5.6
40.6
40.6
30.7
20.8
10.9
34.4
5.7

90
18.9
29.2
39.6
32.9
27.2
33.2
39.2
32.5
35.4
35.6
37.2
38.8
32.1
35.0
43.9
41.1
38.3
31.7
34.6
44.6
38.2
31.6
34.5
46.0
38.1
31.5
34.4

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
12.5
10.1
24.0
18.8
13.6
34.3
27.5
22.3
17.1
32.9
24.3
19.1
13.9
17.4
11.1
27.0
20.7
14.4
36.5
30.3
24.0
17.8
32.5
26.8
20.5
14.3
35.4
29.3
23.0
16.8
22.3
12.2
29.9
22.6
15.3
38.8
33.0
25.7
18.4
32.1
29.2
21.9
14.7
35.0
31.9
24.7
17.4
27.2
13.2
32.8
24.5
16.1
38.3
35.7
27.4
19.1
31.7
31.7
23.4
15.0
34.6
34.6
26.3
18.0
35.4
26.3
17.1
38.2
38.2
29.3
20.1
31.6
31.6
22.4
13.3
34.5
34.5
25.3
16.2
38.1
28.1
18.2
38.1
38.1
31.1
21.2
31.5
31.5
21.5
11.5
34.4
34.4
24.4
14.5

65
8.7
8.0
10.5
7.4
10.1
6.7
9.6
4.1
7.1
1.6
4.5

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

74

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR061 (5.0 Ton) Reheat
Air on
Evaporator Coil
CFM

Total
Capacity1
(MBh)

Total
Input
(kW)2

62.5
64
65.3
62.5
64
65.3
62.5
64
65.3

26.8
28.9
30.0
29.2
30.8
31.4
29.8
31.2
31.4

3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

62.5
64
65.3
62.5
64
65.3
62.5
64
62

26.7
28.9
31.6
27.9
31.0
32.9
26.8
29.5
31.7

3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3

62.5
64
65.3
62.5
64
65.3
62.5
64
65.3

22.8
25.5
27.8
23.2
25.7
27.8
21.6
23.8
26.1

3.5
3.5
3.5
3.5
3.5
3.5
3.4
3.5
3.5

62.5
64
65.3
62.5
64
65.3
62.5
64
62

17.4
19.7
21.6
17.3
19.4
20.9
16.0
18.0
19.4

3.5
3.6
3.6
3.6
3.6
3.6
3.5
3.6
3.6

WB
(°F)

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
(- indicates heating)
Capacity1
Return Dry Bulb (°F)
(MBh)
75
40 °F

1750

2000

2250

50 °F
8.4
6.4
4.8
11.0
8.6
5.8
10.5
7.6
6.0

29.3
32.4
34.7
30.3
32.3
35.3
29.6
32.1
34.5

3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2

9.2
6.9
5.4
10.9
8.4
6.7
9.5
6.9
4.5

24.5
27.0
28.7
25.0
27.3
29.6
23.6
26.1
28.2

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

7.1
5.1
3.3
8.0
5.9
4.3
6.8
4.5
1.9

21.3
23.9
25.8
21.3
23.7
25.7
19.5
22.0
24.1

3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5

3.9
2.0
-0.3
5.0
2.5
0.5
3.5
0.4
-1.7

8.3
9.8
11.2
7.1
8.8
10.3
5.0
6.1
8.3

3.8
3.8
3.9
3.8
3.8
3.9
3.8
3.8
3.9

60 °F
1750

2000

2250

2000

2250

2000

2250

8.0
6.4
4.3
9.0
6.9
4.9
7.3
4.7
2.7
80 °F

85 °F
1750

10.7
9.2
7.3
11.9
9.9
8.4
11.1
8.5
6.2
70 °F

75 °F
1750

Sensible Capacity (MBh)
(- indicates heating)
Return Dry Bulb (°F)
75

Total
Input
(kW)2

6.3
4.6
2.7
7.3
5.3
3.6
5.6
3.1
1.0
95 °F
-1.8
-3.9
-5.3
-0.9
-3.0
-5.2
-3.3
-6.2
-8.0

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

75

528150-YTG-T-0514

ZR078 (6.5 Ton) Cooling
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

1625

1950

2275

2600

2925

3250

76

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

99.9
91.5
83.0
72.4
106.5
97.5
88.5
77.2
78.2
113.1
103.5
93.9
81.9
83.1
119.7
109.5
99.4
86.7
87.9
109.6
99.5
86.8
88.0
109.7
99.6
86.9
88.0

5.1
5.0
5.0
4.9
5.1
5.1
5.1
5.0
5.0
5.2
5.2
5.1
5.1
5.1
5.3
5.2
5.2
5.1
5.2
5.2
5.1
5.1
5.1
5.1
5.1
5.0
5.0

39.3
50.3
61.3
72.4
45.5
57.8
70.1
77.2
78.2
51.6
65.2
78.8
81.9
83.1
57.8
72.7
87.6
86.7
87.9
74.8
91.9
86.8
88.0
76.9
96.1
86.9
88.0

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

81.2
75.9
70.7
64.9
87.0
81.4
75.8
69.7
63.0
92.9
87.0
81.0
74.4
67.3
98.8
92.5
86.1
79.1
71.5
90.8
84.5
77.6
70.2
89.1
83.0
76.2
68.9

6.5
6.5
6.4
6.4
6.6
6.5
6.5
6.4
6.5
6.7
6.6
6.6
6.5
6.5
6.7
6.7
6.6
6.6
6.6
6.6
6.6
6.5
6.6
6.6
6.5
6.5
6.5

34.6
45.6
56.7
64.9
40.1
52.5
64.9
69.7
63.0
45.5
59.3
73.2
74.4
67.3
51.0
66.2
81.4
79.1
71.5
68.3
82.2
77.6
70.2
70.4
83.0
76.2
68.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
33.2
27.1
90.5
5.8
44.2
38.1
32.1
83.7
5.7
55.2
49.2
43.1
37.0
76.9
5.7
70.1
60.9
54.9
48.8
42.7
68.7
5.7
37.9
30.3
96.8
5.9
50.2
42.6
35.1
89.5
5.8
62.5
54.9
47.4
39.8
82.2
5.8
75.6
68.1
60.5
52.9
45.4
73.4
5.7
78.2
72.6
65.0
57.5
49.9
70.6
5.7
42.6
33.5
103.0
5.9
56.2
47.1
38.0
95.2
5.9
69.8
60.7
51.6
42.6
87.5
5.8
81.2
75.2
66.2
57.1
48.0
78.1
5.8
83.1
80.3
71.2
62.1
53.1
75.2
5.8
47.3
36.7
109.3
6.0
62.2
51.6
41.0
101.0
6.0
77.0
66.5
55.9
45.3
92.8
5.9
86.7
82.4
71.8
61.3
50.7
82.9
5.9
87.9
87.9
77.4
66.8
56.2
79.7
5.9
64.0
53.1
42.2
100.2
5.9
79.3
68.4
57.5
46.7
92.0
5.9
86.8
84.6
73.8
62.9
52.0
82.2
5.8
88.0
88.0
77.1
66.2
55.3
79.1
5.8
65.7
54.6
43.4
99.4
5.8
81.5
70.3
59.1
48.0
91.3
5.8
86.9
86.9
75.7
64.5
53.4
81.5
5.8
88.0
88.0
76.8
65.6
54.4
78.5
5.8
95°F
28.4
22.3
76.9
7.3
39.5
33.3
27.2
70.8
7.3
50.5
44.4
38.2
32.1
64.7
7.2
63.3
54.3
48.1
42.0
35.8
59.4
7.2
32.5
25.0
81.8
7.4
45.0
37.5
30.0
75.3
7.4
57.4
49.9
42.4
34.9
68.8
7.3
68.6
61.0
53.5
46.0
38.5
63.2
7.3
63.0
58.6
51.1
43.5
36.0
61.6
7.3
36.7
27.8
86.7
7.5
50.5
41.6
32.8
79.8
7.5
64.3
55.4
46.6
37.7
73.0
7.4
73.8
67.8
59.0
50.1
41.2
67.0
7.3
67.3
65.1
56.2
47.3
38.5
65.2
7.4
40.8
30.6
91.6
7.6
56.0
45.8
35.6
84.3
7.6
71.2
61.0
50.8
40.5
77.1
7.5
79.1
74.6
64.4
54.2
43.9
70.8
7.4
71.5
71.5
61.3
51.1
40.9
68.9
7.4
57.6
47.0
36.3
83.1
7.5
73.2
62.6
51.9
41.3
75.9
7.4
77.6
75.4
64.7
54.1
43.4
69.7
7.4
70.2
70.2
59.6
48.9
38.3
67.9
7.4
59.3
48.2
37.1
81.8
7.4
75.3
64.2
53.1
42.0
74.8
7.4
76.2
76.2
65.1
54.0
42.9
68.6
7.3
68.9
68.9
57.8
46.8
35.7
66.9
7.3

90
36.9
48.0
59.0
68.7
42.8
55.1
67.5
73.4
70.6
48.6
62.3
76.0
78.1
75.2
54.4
69.5
84.5
82.9
79.7
71.6
87.0
82.2
79.1
73.7
89.5
81.5
78.5
31.0
43.2
55.3
59.4
37.4
49.6
61.8
63.2
61.6
43.8
56.0
68.3
67.0
65.2
50.2
62.5
74.7
70.8
68.9
64.7
74.8
69.7
67.9
66.9
74.8
68.6
66.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
30.8
24.7
41.8
35.7
29.6
52.9
46.8
40.7
34.5
66.7
57.6
51.5
45.4
35.2
27.7
47.6
40.0
32.5
60.0
52.4
44.9
37.3
72.1
64.6
57.0
49.5
70.6
65.6
58.0
50.5
39.6
30.7
53.3
44.4
35.4
67.0
58.1
49.1
40.1
77.5
71.5
62.6
53.6
75.2
72.7
63.7
54.7
44.0
33.6
59.1
48.7
38.3
74.1
63.7
53.3
42.9
82.9
78.5
68.1
57.7
79.7
79.7
69.3
59.0
60.8
50.0
39.3
76.3
65.5
54.7
44.0
82.2
80.0
69.3
58.5
79.1
79.1
68.3
57.6
62.5
51.4
40.3
78.4
67.3
56.1
45.0
81.5
81.5
70.4
59.3
78.5
78.5
67.3
56.2
105°F
26.2
20.1
37.1
31.0
24.8
47.9
41.8
35.7
29.6
58.5
49.9
43.8
37.7
30.0
22.6
42.2
34.8
27.4
54.4
47.0
39.6
32.1
62.6
56.1
48.7
41.3
61.4
55.5
48.1
40.6
33.8
25.1
47.3
38.6
29.9
60.9
52.2
43.5
34.7
66.7
62.3
53.6
44.9
65.1
61.6
52.9
44.2
37.6
27.6
52.5
42.5
32.5
67.3
57.3
47.3
37.3
70.8
68.5
58.5
48.5
68.9
67.7
57.7
47.7
54.2
43.8
33.3
69.1
59.1
48.7
38.2
69.7
68.6
58.1
47.7
67.9
67.3
56.8
46.4
56.0
45.1
34.2
70.9
60.9
50.0
39.1
68.6
68.6
57.7
46.8
66.9
66.9
56.0
45.1

65
39.3
41.9
43.0
44.6
45.8
47.3
48.6
47.7
46.8
48.1
45.1
31.6
33.9
33.2
36.2
35.5
38.5
37.7
37.2
35.9
35.9
34.2

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR078 (6.5 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

72.6
65.6
58.6
53.8
76.5
69.1
61.8
56.7
60.1
80.4
72.7
64.9
59.6
63.2
84.3
76.2
68.1
62.5
66.3
75.4
67.3
61.8
65.5
74.5
66.6
61.1
64.8

8.1
8.1
8.1
8.0
8.2
8.2
8.2
8.1
8.1
8.4
8.3
8.3
8.2
8.2
8.5
8.4
8.4
8.3
8.3
8.3
8.3
8.2
8.2
8.3
8.2
8.1
8.1

27.5
40.7
54.0
53.8
34.8
46.7
58.7
56.7
60.1
42.1
52.7
63.4
59.6
63.2
49.4
58.8
68.1
62.5
66.3
61.1
67.3
61.8
65.5
63.4
66.6
61.1
64.8

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
24.0
18.0
68.3
9.0
34.7
28.6
22.5
60.4
8.9
45.3
39.2
33.1
27.1
52.6
8.9
53.8
45.6
39.5
33.4
27.4
48.2
8.8
27.5
20.2
71.2
9.1
39.4
32.1
24.8
63.0
9.0
51.4
44.0
36.7
29.4
54.7
9.0
56.7
51.2
43.9
36.6
29.3
50.2
8.9
59.7
52.4
45.1
37.7
30.4
58.7
8.9
31.0
22.4
74.1
9.2
44.2
35.6
27.1
65.5
9.2
57.4
48.9
40.3
31.8
56.9
9.1
59.6
56.8
48.3
39.7
31.2
52.2
9.0
63.0
58.1
49.6
41.0
32.5
61.2
9.0
34.4
24.6
77.1
9.3
49.0
39.2
29.4
68.1
9.3
63.5
53.7
43.9
34.1
59.1
9.2
62.5
62.5
52.7
42.9
33.1
54.2
9.1
66.3
63.9
54.1
44.3
34.5
63.6
9.1
50.8
40.6
30.3
67.6
9.2
65.0
55.7
45.4
35.1
58.7
9.2
61.8
61.8
51.5
41.3
31.0
53.8
9.0
65.5
64.3
54.1
43.8
33.6
63.2
9.0
52.7
42.0
31.3
67.2
9.1
66.6
57.6
46.9
36.2
58.4
9.1
61.1
61.1
50.4
39.7
28.9
53.5
8.9
64.8
64.8
54.1
43.4
32.7
62.7
9.0

90
24.0
38.3
52.6
48.2
33.0
43.9
54.7
50.2
58.7
42.0
49.4
56.9
52.2
61.2
51.0
55.0
59.1
54.2
63.6
57.5
58.7
53.8
63.2
59.9
58.4
53.5
62.7

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
21.5
15.8
32.2
26.2
20.2
42.6
36.6
30.6
24.6
48.2
41.2
35.2
29.2
25.0
17.8
36.6
29.4
22.2
48.3
41.1
33.9
26.7
50.2
46.3
39.1
31.9
58.0
49.3
42.1
34.8
28.4
19.7
41.0
32.6
24.2
54.0
45.6
37.2
28.8
52.2
51.4
43.0
34.6
60.8
54.7
46.3
37.9
31.8
21.6
45.4
35.9
26.3
59.1
50.1
40.5
30.9
54.2
54.2
46.8
37.2
63.6
60.0
50.5
40.9
47.4
37.4
27.3
58.7
52.2
42.1
32.1
53.8
53.8
44.9
34.9
63.2
61.4
51.3
41.3
49.4
38.9
28.3
58.4
54.3
43.7
33.2
53.5
53.5
43.0
32.5
62.7
62.7
52.2
41.7

65
23.1
24.7
27.6
26.2
29.5
27.7
31.3
24.8
31.2
22.0
31.2

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

77

528150-YTG-T-0514

ZR078 (6.5 Ton) Reheat
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

1625

1950

2275

2600

2925

3250

78

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

31.6
32.2
28.5
36.1
36.7
32.6
34.2
40.5
41.2
36.7
38.3
45.0
45.7
40.8
42.5
42.5
43.2
38.5
40.2
40.0
40.6
36.2
37.9

4.5
4.6
4.4
4.3
4.5
4.3
4.4
4.2
4.3
4.2
4.2
4.1
4.2
4.0
4.1
4.0
4.1
4.0
4.0
3.9
4.0
3.9
4.0

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

38.2
38.2
35.5
38.4
38.4
35.7
34.7
38.6
38.6
35.9
34.9
38.8
38.9
36.1
35.1
39.0
39.1
36.3
35.3
39.2
39.3
36.5
35.5

5.7
5.1
5.3
5.5
4.9
5.1
5.1
5.2
4.7
4.9
4.8
5.0
4.4
4.6
4.6
5.2
4.6
4.8
4.8
5.3
4.8
5.0
5.0

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
35°F
1.6
1.5
1.5
34.9
5.1
1.5
1.5
1.4
1.4
35.2
4.9
1.6
1.6
1.5
1.5
1.4
32.0
4.9
2.2
1.6
0.9
37.2
4.9
6.6
5.9
5.3
4.6
37.6
4.7
10.8
10.1
9.4
8.8
8.1
34.2
4.7
17.1
16.4
15.8
15.1
14.5
34.5
4.7
2.9
1.7
0.4
39.6
4.7
11.6
10.4
9.1
7.8
39.9
4.5
19.9
18.6
17.4
16.1
14.8
36.3
4.5
29.8
29.5
28.2
26.9
25.7
36.6
4.5
3.6
1.7
-0.1
41.9
4.5
16.7
14.8
12.9
11.1
42.3
4.3
29.0
27.1
25.3
23.4
21.6
38.4
4.3
42.5
42.5
40.6
38.7
36.9
38.8
4.4
4.6
2.8
1.0
40.8
4.6
17.5
15.7
13.9
12.1
41.1
4.4
31.6
29.1
27.3
25.5
23.7
37.4
4.4
40.2
40.2
38.3
36.5
34.7
37.7
4.4
5.7
3.9
2.1
39.6
4.6
18.4
16.6
14.8
13.0
40.0
4.4
34.2
31.1
29.3
27.5
25.8
36.3
4.4
37.9
37.9
36.1
34.3
32.5
36.7
4.5
55°F
36.3
5.7
3.4
2.9
2.4
1.9
36.2
5.3
8.8
8.3
7.8
7.3
6.7
33.1
5.2
36.8
5.6
5.8
5.2
4.5
3.9
36.7
5.2
15.3
14.7
14.0
13.3
12.7
33.5
5.0
19.4
18.7
18.1
17.4
16.8
32.9
5.0
37.3
5.4
8.3
7.5
6.6
5.8
37.2
5.0
21.9
21.0
20.2
19.4
18.6
34.0
4.9
27.2
26.9
26.1
25.3
24.5
33.4
4.9
37.8
5.3
10.7
9.7
8.8
7.8
37.7
4.9
28.4
27.4
26.5
25.5
24.6
34.4
4.8
35.1
35.1
34.1
33.2
32.2
33.8
4.8
38.0
5.4
12.9
11.7
10.6
9.5
38.0
5.0
32.4
32.0
30.8
29.7
28.6
34.6
4.9
35.3
35.3
34.2
33.0
31.9
34.1
4.9
38.2
5.5
15.0
13.7
12.5
11.2
38.2
5.0
36.5
36.5
35.2
33.9
32.6
34.8
4.9
35.5
35.5
34.2
32.9
31.6
34.3
4.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
45°F
2.5
2.2
1.9
1.7
5.2
4.9
4.6
4.4
6.2
5.6
4.9
4.2
13.0
12.4
11.7
11.1
18.2
17.6
16.9
16.3
9.9
8.9
7.9
6.8
20.9
19.8
18.8
17.8
28.5
28.2
27.2
26.1
13.7
12.3
10.8
9.4
28.7
27.3
25.9
24.5
38.8
38.8
37.4
36.0
15.2
13.7
12.2
10.8
32.0
30.5
29.1
27.6
37.7
37.7
36.2
34.8
16.7
15.2
13.6
12.1
35.3
33.8
32.3
30.7
36.7
36.7
35.1
33.6
65°F
2.4
2.1
1.8
1.5
6.5
6.2
5.9
5.6
4.9
4.3
3.8
3.2
13.9
13.3
12.7
12.2
17.0
16.5
15.9
15.3
7.4
6.6
5.8
5.0
21.2
20.4
19.6
18.8
25.4
25.2
24.3
23.5
9.9
8.9
7.8
6.8
28.5
27.5
26.4
25.3
33.8
33.8
32.8
31.7
12.2
10.9
9.7
8.4
31.7
31.2
29.9
28.7
34.1
34.1
32.8
31.6
14.4
13.0
11.6
10.1
34.8
34.8
33.4
32.0
34.3
34.3
32.8
31.4

65
4.1
10.4
15.6
16.7
25.1
23.1
34.5
26.1
33.3
29.2
32.0
5.3
11.6
14.8
18.0
22.7
24.3
30.7
27.4
30.3
30.5
29.9

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR078 (6.5 Ton) Reheat (Continued)
Air on
Evaporator Coil
CFM

1625

1950

2275

2600

2925

3250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

34.3
34.2
30.6
35.1
35.0
31.3
31.2
35.9
35.8
32.0
31.9
36.7
36.6
32.7
32.6
37.0
36.9
33.0
32.8
37.2
37.1
33.2
33.1

5.7
5.4
5.0
5.7
5.4
5.0
5.0
5.7
5.4
5.0
5.0
5.7
5.4
5.0
5.0
5.6
5.4
4.9
4.9
5.6
5.3
4.9
4.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
32.4
5.6
1.3
1.2
1.1
1.0
32.2
5.6
4.3
4.2
4.1
4.0
3.9
28.2
4.8
33.5
5.8
4.0
3.5
3.0
2.6
33.3
5.7
12.4
12.0
11.5
11.0
10.6
29.1
4.9
14.6
14.2
13.7
13.3
12.8
29.4
4.9
34.5
5.9
6.6
5.8
5.0
4.2
34.4
5.8
20.5
19.7
18.9
18.1
17.3
30.1
5.1
23.6
23.4
22.6
21.8
21.0
30.4
5.0
35.6
6.0
9.2
8.1
6.9
5.7
35.5
5.9
28.7
27.5
26.3
25.2
24.0
31.0
5.2
32.6
32.6
31.4
30.3
29.1
31.3
5.2
35.9
5.8
11.5
10.2
8.8
7.4
35.8
5.8
30.9
30.4
29.0
27.6
26.2
31.3
5.0
32.8
32.8
31.5
30.1
28.7
31.6
5.0
36.2
5.7
13.9
12.3
10.7
9.1
36.1
5.6
33.2
33.2
31.6
30.0
28.4
31.6
4.9
33.1
33.1
31.5
29.9
28.3
31.9
4.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
0.3
0.4
0.5
0.6
2.1
2.2
2.2
2.3
3.0
2.7
2.3
1.9
11.0
10.6
10.3
9.9
12.2
11.9
11.5
11.2
5.7
4.9
4.1
3.3
19.9
19.1
18.3
17.4
21.8
21.6
20.8
20.0
8.5
7.2
6.0
4.7
28.8
27.5
26.3
25.0
31.3
31.3
30.1
28.8
10.9
9.4
7.9
6.4
30.2
29.6
28.0
26.5
31.6
31.6
30.1
28.6
13.3
11.5
9.8
8.0
31.6
31.6
29.8
28.1
31.9
31.9
30.1
28.4

65
2.4
9.5
10.8
16.6
19.2
23.8
27.6
25.0
27.1
26.3
26.6

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

79

528150-YTG-T-0514

ZR090 (7.5 Ton) Cooling
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

1875

2250

2625

3000

3375

3750

80

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

95.3
88.9
82.4
72.3
104.3
97.2
90.1
79.1
76.9
113.3
105.5
97.8
85.9
83.6
122.2
113.8
105.4
92.7
90.2
116.9
108.2
95.1
92.7
119.9
111.0
97.6
95.1

5.1
5.0
4.9
4.9
5.1
5.0
5.0
4.9
4.9
5.2
5.1
5.0
5.0
5.0
5.2
5.1
5.1
5.0
5.0
5.2
5.1
5.1
5.1
5.2
5.1
5.1
5.1

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

101.5
93.1
84.7
76.8
104.3
95.7
87.0
78.9
78.3
107.1
98.2
89.3
81.0
80.4
109.9
100.7
91.6
83.1
82.4
101.5
92.3
83.7
83.1
102.3
93.0
84.3
83.7

6.6
6.6
6.5
6.5
6.6
6.6
6.5
6.5
6.5
6.6
6.6
6.5
6.5
6.5
6.6
6.6
6.5
6.5
6.5
6.6
6.5
6.5
6.5
6.6
6.6
6.5
6.5

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
90
85
80
75
70
65
75°F
41.7
33.4
25.0
98.4
5.8
49.7
41.3
33.0
24.6
91.0
5.8
57.7
49.3
41.0
32.6
24.2
83.6
5.7
72.3
63.4
49.7
41.3
32.9
24.6
74.5
5.7
50.1
40.6
31.2
104.3
5.9
60.3
50.9
41.4
32.0
96.4
5.8
70.6
61.1
51.7
42.2
32.8
88.5
5.8
79.1
73.2
62.8
53.3
43.9
34.4
79.0
5.7
76.9
74.8
63.8
54.3
44.9
35.4
77.6
5.7
58.4
47.9
37.4
110.2
5.9
70.9
60.4
49.9
39.4
101.9
5.8
83.4
72.9
62.4
51.9
41.3
93.5
5.8
85.9
82.9
75.8
65.3
54.8
44.3
83.4
5.7
83.6
82.5
77.0
66.5
55.9
45.4
82.0
5.7
66.8
55.2
43.6
116.0
5.9
81.6
69.9
58.3
46.7
107.3
5.9
96.3
84.7
73.1
61.5
49.9
98.5
5.8
92.7
92.7
88.9
77.3
65.7
54.1
87.9
5.8
90.2
90.2
90.2
78.6
67.0
55.4
86.3
5.8
86.8
74.3
61.8
49.4
109.2
5.9
103.7 89.9
77.5
65.0
52.5
100.3
5.8
95.1
95.1
93.3
80.8
68.4
55.9
89.4
5.8
92.7
92.7
92.7
80.2
67.7
55.3
87.9
5.8
92.0
78.7
65.3
52.0
111.1
5.9
111.0 95.2
81.9
68.5
55.2
102.0
5.8
97.6
97.6
97.6
84.3
71.0
57.7
91.0
5.8
95.1
95.1
95.1
81.8
68.4
55.1
89.4
5.8
95°F
43.2
35.6
27.9
94.5
7.5
55.7
48.0
40.3
32.7
86.4
7.5
68.2
60.5
52.8
45.1
37.4
78.3
7.5
76.8
76.8
65.4
57.7
50.0
42.3
71.2
7.4
47.9
39.1
30.3
96.9
7.5
61.5
52.7
43.9
35.0
88.5
7.5
75.0
66.2
57.4
48.6
39.8
80.2
7.4
78.9
78.9
71.0
62.2
53.4
44.6
73.0
7.4
78.3
78.3
71.1
62.2
53.4
44.6
73.0
7.4
52.6
42.6
32.7
99.2
7.5
67.2
57.3
47.4
37.4
90.6
7.5
81.9
72.0
62.0
52.1
42.1
82.1
7.4
81.0
81.0
76.7
66.8
56.9
46.9
74.7
7.4
80.4
80.4
76.7
66.8
56.9
46.9
74.8
7.4
57.3
46.2
35.1
101.5
7.5
73.0
61.9
50.9
39.8
92.7
7.5
88.7
77.7
66.6
55.6
44.5
84.0
7.4
83.1
83.1
82.4
71.4
60.3
49.2
76.5
7.4
82.4
82.4
82.4
71.4
60.3
49.3
76.5
7.4
78.2
66.2
54.2
42.2
93.0
7.4
90.9
82.9
70.9
58.9
46.9
84.3
7.4
83.7
83.7
83.4
71.4
59.4
47.4
76.7
7.4
83.1
83.1
83.1
71.1
59.1
47.1
76.7
7.4
83.3
70.4
57.5
44.5
93.3
7.4
93.0
88.2
75.2
62.3
49.4
84.5
7.4
84.3
84.3
84.3
71.4
58.5
45.5
76.9
7.4
83.7
83.7
83.7
70.7
57.8
44.9
76.9
7.4

90
42.5
52.7
63.0
74.5
49.0
60.9
72.8
79.0
77.6
55.5
69.1
82.7
83.4
82.0
62.0
77.3
92.5
87.9
86.3
82.5
97.3
89.4
87.9
87.7
102.0
91.0
89.4
39.4
52.8
66.2
71.2
45.1
58.4
71.7
73.0
73.0
50.7
63.9
77.1
74.7
74.8
56.4
69.5
82.6
76.5
76.5
74.7
83.5
76.7
76.7
79.9
84.5
76.9
76.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
34.5
26.4
44.7
36.7
28.6
54.9
46.9
38.9
30.8
70.1
57.5
49.5
41.5
39.9
30.7
51.8
42.6
33.5
63.7
54.5
45.4
36.3
76.0
66.9
57.8
48.6
76.5
67.4
58.3
49.1
45.3
35.0
58.9
48.6
38.4
72.4
62.2
52.0
41.7
82.0
76.3
66.1
55.8
81.4
76.9
66.6
56.4
50.7
39.4
65.9
54.6
43.3
81.2
69.9
58.5
47.2
87.9
85.7
74.3
63.0
86.3
86.3
75.0
63.7
70.2
58.0
45.8
86.4
74.2
62.0
49.7
89.4
88.3
76.1
63.9
87.9
87.9
75.6
63.4
74.5
61.4
48.3
91.7
78.5
65.4
52.3
91.0
91.0
77.9
64.7
89.4
89.4
76.3
63.1
105°F
33.0
25.5
45.3
37.7
30.2
57.5
50.0
42.5
34.9
71.2
60.6
53.1
45.5
36.4
27.7
49.7
41.0
32.3
63.0
54.3
45.6
36.9
73.0
65.8
57.1
48.4
73.0
66.1
57.4
48.7
39.7
29.8
54.1
44.2
34.3
68.4
58.6
48.7
38.8
74.7
70.9
61.1
51.2
74.8
71.3
61.4
51.6
43.0
32.0
58.5
47.4
36.4
73.9
62.8
51.8
40.8
76.5
76.1
65.1
54.1
76.5
76.5
65.5
54.4
62.7
50.8
38.8
78.0
67.3
55.3
43.4
76.7
76.5
64.6
52.6
76.7
76.7
64.8
52.8
67.0
54.1
41.2
82.1
71.7
58.8
46.0
76.9
76.9
64.0
51.1
76.9
76.9
64.0
51.1

65
33.4
39.5
40.0
45.6
46.2
51.7
52.3
51.6
51.2
51.6
50.0
38.0
39.7
40.0
41.4
41.7
43.0
43.4
40.6
40.8
38.2
38.3

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR090 (7.5 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

87.6
79.7
71.9
65.7
89.4
81.4
73.4
67.1
67.8
91.2
83.1
74.9
68.5
69.2
93.1
84.7
76.4
69.8
70.6
84.5
76.2
69.6
70.4
84.3
76.0
69.5
70.2

8.4
8.4
8.4
8.3
8.3
8.3
8.4
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.2

35.5
49.9
64.3
65.7
42.2
55.2
68.3
67.1
67.8
48.9
60.6
72.3
68.5
69.2
55.5
66.0
76.4
69.8
70.6
71.2
76.2
69.6
70.4
76.5
76.0
69.5
70.2

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
30.5
23.1
80.6
9.2
42.5
35.1
27.8
73.0
9.2
54.6
47.2
39.8
32.4
65.5
9.3
65.7
55.8
48.4
41.1
33.7
60.2
9.3
33.6
25.0
82.0
9.2
46.7
38.1
29.5
74.3
9.2
59.7
51.1
42.6
34.0
66.6
9.3
67.1
60.5
51.9
43.3
34.7
61.2
9.2
67.8
61.1
52.5
43.9
35.4
62.5
9.2
36.8
27.0
83.3
9.2
50.8
41.0
31.2
75.5
9.2
64.9
55.1
45.3
35.5
67.7
9.2
68.5
65.2
55.4
45.6
35.8
62.2
9.2
69.2
65.8
56.0
46.3
36.5
63.6
9.2
39.9
28.9
84.7
9.2
55.0
44.0
33.0
76.7
9.2
70.0
59.1
48.1
37.1
68.8
9.2
69.8
69.8
58.8
47.9
36.9
63.2
9.2
70.6
70.6
59.6
48.6
37.6
64.6
9.2
59.3
47.4
35.5
76.0
9.2
73.0
63.6
51.7
39.8
68.1
9.2
69.6
69.6
57.7
45.8
33.9
62.6
9.2
70.4
70.4
58.4
46.5
34.6
64.0
9.1
63.7
50.8
38.0
75.3
9.1
76.0
68.2
55.4
42.5
67.5
9.2
69.5
69.5
56.6
43.8
30.9
62.0
9.2
70.2
70.2
57.3
44.5
31.6
63.4
9.1

90
30.9
47.0
62.3
60.2
39.3
52.1
64.9
61.2
62.5
47.7
57.3
67.6
62.2
63.6
56.1
62.4
68.8
63.2
64.6
67.8
68.1
62.6
64.0
73.1
67.5
62.0
63.4

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
27.9
20.7
39.8
32.5
25.3
51.6
44.4
37.2
29.9
60.2
51.0
43.8
36.6
30.9
22.4
43.7
35.2
26.7
56.5
48.0
39.5
31.1
61.2
55.2
46.7
38.3
62.5
56.1
47.7
39.2
33.8
24.1
47.6
37.9
28.2
61.3
51.6
41.9
32.2
62.2
59.4
49.7
40.0
63.6
60.4
50.7
40.9
36.7
25.8
51.5
40.5
29.6
66.2
55.3
44.3
33.4
63.2
63.2
52.6
41.6
64.6
64.6
53.6
42.7
55.9
44.0
32.1
68.1
60.0
48.1
36.2
62.6
62.6
50.9
39.0
64.0
64.0
52.1
40.3
60.3
47.5
34.7
67.5
64.7
51.9
39.1
62.0
62.0
49.2
36.4
63.4
63.4
50.6
37.8

65
29.4
29.8
30.7
30.2
31.2
30.7
31.7
27.1
28.4
23.6
25.0

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

81

528150-YTG-T-0514

ZR090 (7.5 Ton) Reheat
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

1875

2250

2625

3000

3375

3750

82

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

57.4
54.9
52.4
48.7
62.8
60.0
57.2
53.0
49.6
68.1
65.0
61.9
57.4
53.7
73.4
70.0
66.6
61.8
57.8
71.8
68.3
63.3
59.3
73.5
69.9
64.9
60.7

4.6
4.4
4.3
4.1
4.5
4.4
4.2
4.0
4.0
4.5
4.3
4.2
4.0
3.9
4.5
4.3
4.2
4.0
3.9
4.3
4.2
4.0
3.9
4.3
4.2
4.0
3.9

7.7
14.9
21.7
11.2
22.2
32.6
37.1
14.8
29.5
43.6
47.5
18.4
36.8
54.5
57.8
18.9
37.5
58.3
59.3
19.4
38.2
62.1
60.7

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

59.9
54.2
48.5
44.6
62.6
56.6
50.7
46.6
46.2
65.2
59.0
52.8
48.5
48.1
67.8
61.4
54.9
50.5
50.1
63.0
56.4
51.8
51.4
64.6
57.9
53.2
52.7

5.1
4.9
4.7
4.5
5.1
4.9
4.7
4.5
4.4
5.1
4.9
4.6
4.4
4.4
5.1
4.8
4.6
4.4
4.3
4.8
4.6
4.4
4.3
4.8
4.6
4.4
4.3

3.9
12.6
22.2
5.4
17.0
29.9
35.3
6.8
21.4
37.7
42.7
8.2
25.8
45.4
50.1
9.6
29.8
49.3
51.4
11.0
33.9
53.2
52.7

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
35°F
58.7
4.9
6.3
4.9
3.5
54.6
4.7
13.5
12.1
10.7
9.3
50.5
4.5
20.3
18.9
17.5
16.1
14.7
46.6
4.3
62.7
4.8
9.1
7.0
4.9
58.3
4.6
20.1
18.0
15.9
13.8
53.9
4.4
30.5
28.4
26.3
24.2
22.1
49.8
4.2
35.0
32.9
30.8
28.7
26.6
47.9
4.2
66.6
4.8
12.0
9.2
6.4
62.0
4.6
26.7
23.9
21.1
18.3
57.3
4.4
40.8
38.0
35.2
32.4
29.6
53.0
4.2
46.4
44.0
41.2
38.4
35.6
50.9
4.1
70.6
4.8
14.9
11.4
7.9
65.7
4.6
33.3
29.8
26.3
22.8
60.8
4.4
51.0
47.5
44.0
40.5
37.0
56.1
4.2
57.8
55.1
51.6
48.1
44.6
54.0
4.1
15.5
12.1
8.6
67.4
4.6
34.0
30.6
27.2
23.8
62.3
4.4
53.2
48.3
44.9
41.4
38.0
57.6
4.2
59.3
57.9
54.5
51.1
47.6
55.3
4.1
16.1
12.7
9.4
69.1
4.6
34.8
31.4
28.1
24.7
63.9
4.4
55.3
49.1
45.7
42.4
39.0
59.0
4.2
60.7
60.7
57.4
54.0
50.6
56.7
4.1
55°F
57.9
5.4
2.7
1.6
51.6
5.2
11.4
10.2
9.0
7.9
45.3
5.0
21.0
19.9
18.7
17.5
16.4
42.1
4.8
59.7
5.4
3.7
2.1
53.2
5.2
15.4
13.7
12.1
10.5
46.6
4.9
28.3
26.7
25.1
23.5
21.8
43.4
4.7
33.7
32.1
30.4
28.8
27.2
42.7
4.7
61.4
5.4
4.7
2.7
54.7
5.1
19.3
17.3
15.2
13.1
48.0
4.9
35.6
33.6
31.5
29.4
27.3
44.7
4.7
41.9
40.3
38.2
36.1
34.1
43.9
4.6
63.1
5.3
5.7
3.2
56.2
5.1
23.3
20.8
18.3
15.7
49.4
4.9
42.9
40.4
37.9
35.4
32.8
45.9
4.7
50.1
48.5
46.0
43.4
40.9
45.2
4.6
6.6
3.7
57.9
5.1
26.9
23.9
21.0
18.0
50.8
4.9
48.0
46.5
43.6
40.6
37.6
47.3
4.7
51.4
50.6
47.6
44.7
41.7
46.5
4.6
7.6
4.2
59.6
5.1
30.5
27.1
23.7
20.3
52.3
4.9
53.2
52.7
49.3
45.9
42.5
48.7
4.7
52.7
52.7
49.3
45.9
42.5
47.9
4.6

90
5.8
13.7
21.9
8.3
19.6
31.3
36.2
10.8
25.4
40.6
45.1
13.3
31.3
50.0
54.0
14.3
33.7
53.8
55.3
15.2
36.0
57.6
56.7
1.5
11.0
22.4
2.2
14.3
28.8
33.5
2.9
17.6
35.2
39.3
3.6
20.9
41.7
45.2
4.1
25.7
45.2
46.5
4.6
30.5
48.7
47.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
45°F
4.5
3.2
1.9
12.4
11.1
9.9
8.6
20.7
19.4
18.1
16.8
6.4
4.6
2.7
17.7
15.9
14.0
12.1
29.4
27.6
25.7
23.8
34.3
32.5
30.6
28.8
8.4
5.9
3.5
23.0
20.6
18.1
15.7
38.2
35.8
33.3
30.9
44.1
42.1
39.7
37.3
10.3
7.3
4.3
28.3
25.3
22.3
19.3
47.0
44.0
40.9
37.9
54.0
51.8
48.8
45.8
11.1
7.9
4.7
30.5
27.3
24.1
20.9
50.6
47.4
44.2
41.0
55.3
54.3
51.1
47.9
11.8
8.4
5.1
32.6
29.3
25.9
22.5
54.3
50.9
47.5
44.1
56.7
56.7
53.3
50.0
65°F
10.0
9.0
7.9
6.9
21.4
20.4
19.3
18.3
12.9
11.6
10.2
8.9
27.5
26.1
24.7
23.4
32.2
30.8
29.4
28.1
1.2
15.9
14.2
12.5
10.8
33.5
31.8
30.1
28.4
38.7
37.6
35.9
34.2
1.5
18.9
16.8
14.7
12.7
39.6
37.6
35.5
33.5
45.2
44.4
42.3
40.3
1.5
23.2
20.6
18.0
15.5
44.1
43.0
40.4
37.9
46.5
46.1
43.6
41.0
1.5
27.5
24.4
21.3
18.2
48.7
48.4
45.3
42.2
47.9
47.9
44.8
41.7

65
15.5
22.0
26.9
28.5
34.8
34.9
42.8
37.8
44.7
40.7
46.6
17.3
22.0
26.7
26.7
32.5
31.4
38.2
35.3
38.4
39.2
38.6

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR090 (7.5 Ton) Reheat (Continued)
Air on
Evaporator Coil
CFM

1875

2250

2625

3000

3375

3750

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

56.0
49.0
42.0
39.6
56.8
49.7
42.6
40.2
39.2
57.6
50.4
43.2
40.8
39.7
58.4
51.1
43.8
41.4
40.3
52.8
45.3
42.8
41.6
54.5
46.8
44.1
43.0

5.7
5.5
5.2
5.0
5.7
5.5
5.2
5.0
4.9
5.7
5.4
5.2
5.0
4.9
5.6
5.4
5.2
5.0
4.9
5.4
5.2
5.0
4.9
5.4
5.1
4.9
4.9

9.4
22.6
11.6
27.7
31.7
13.8
32.8
36.0
16.0
37.9
40.3
21.6
41.0
41.6
27.2
44.1
43.0

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
54.0
6.0
46.3
5.8
8.6
7.7
6.8
6.0
38.7
5.5
21.7
20.9
20.0
19.1
18.3
37.2
5.3
53.9
6.0
46.2
5.7
10.5
9.4
8.3
7.2
38.6
5.5
26.6
25.5
24.4
23.3
22.2
37.0
5.3
30.6
29.5
28.4
27.3
26.2
35.6
5.2
53.8
5.9
46.1
5.7
12.5
11.1
9.8
8.4
38.4
5.5
31.5
30.1
28.8
27.4
26.1
36.9
5.3
35.5
34.9
33.6
32.2
30.9
35.5
5.2
53.6
5.9
45.9
5.7
14.4
12.8
11.2
9.7
38.2
5.4
36.3
34.7
33.2
31.6
30.0
36.8
5.3
40.3
40.3
38.7
37.1
35.5
35.4
5.2
47.7
5.7
19.4
17.3
15.1
12.9
39.7
5.4
40.2
39.4
37.3
35.1
32.9
38.2
5.2
41.6
41.6
39.5
37.3
35.1
36.7
5.2
49.5
5.6
24.4
21.7
18.9
16.2
41.2
5.4
44.1
44.1
41.4
38.6
35.9
39.6
5.2
43.0
43.0
40.2
37.5
34.7
38.1
5.1

90
7.8
22.7
8.9
26.5
30.0
10.0
30.4
32.7
11.1
34.2
35.4
17.5
36.9
36.7
23.9
39.6
38.1

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
7.1
6.4
5.8
5.1
22.0
21.3
20.7
20.0
8.1
7.3
6.4
5.6
25.7
24.9
24.0
23.2
29.1
28.3
27.4
26.6
9.0
8.1
7.1
6.1
29.4
28.4
27.4
26.4
32.2
32.2
31.2
30.3
10.0
8.9
7.7
6.6
33.0
31.9
30.8
29.7
35.4
35.4
35.0
33.9
15.7
13.9
12.2
10.4
36.3
35.9
34.1
32.4
36.7
36.7
35.4
33.6
21.4
19.0
16.6
14.1
39.6
39.6
37.5
35.0
38.1
38.1
35.7
33.3

65
19.3
22.4
25.8
25.5
29.3
28.5
32.8
30.6
31.8
32.6
30.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

83

528150-YTG-T-0514

ZR102 (8.5 Ton) Cooling
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

2125

2550

2975

3400

3825

4250

84

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

121.9
118.1
114.3
105.8
126.3
122.4
118.4
109.7
107.0
130.7
126.6
122.6
113.5
110.8
135.1
130.9
126.7
117.3
114.5
130.9
126.8
117.4
114.5
131.0
126.8
117.4
114.6

6.4
6.4
6.3
6.2
6.5
6.4
6.4
6.2
6.3
6.5
6.4
6.4
6.3
6.3
6.5
6.5
6.4
6.3
6.4
6.5
6.4
6.3
6.4
6.5
6.5
6.3
6.4

54.3
71.1
87.8
105.8
59.7
79.1
98.4
109.7
107.0
65.1
87.0
108.9
113.5
110.8
70.6
95.0
119.5
117.3
114.5
99.4
123.1
117.4
114.5
103.7
126.8
117.4
114.6

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

115.5
107.5
99.5
91.9
119.5
111.3
103.0
95.2
92.1
123.6
115.1
106.5
98.5
95.2
127.7
118.9
110.1
101.7
98.4
119.8
110.9
102.5
99.2
120.8
111.8
103.3
99.9

8.3
8.1
8.0
7.9
8.3
8.2
8.0
7.9
7.9
8.3
8.2
8.0
7.9
8.0
8.4
8.2
8.1
8.0
8.0
8.3
8.1
8.0
8.0
8.3
8.1
8.0
8.1

50.3
66.9
83.4
91.9
57.6
75.0
92.3
95.2
92.1
64.9
83.1
101.2
98.5
95.2
72.3
91.2
110.1
101.7
98.4
97.1
110.9
102.5
99.2
103.1
111.8
103.3
99.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
43.2
32.9
118.7
7.4
60.8
50.5
40.2
112.8
7.3
78.4
68.1
57.8
47.5
106.9
7.2
98.7
83.7
73.4
63.1
52.8
98.9
7.0
47.9
36.1
122.9
7.4
67.3
55.5
43.7
116.8
7.3
86.6
74.8
63.0
51.2
110.7
7.2
104.9 92.0
80.2
68.4
56.6
102.4
7.1
107.0 97.1
85.3
73.5
61.7
99.6
7.1
52.7
39.4
127.2
7.4
73.7
60.5
47.2
120.9
7.3
94.8
81.5
68.2
54.9
114.6
7.2
111.1 100.2 86.9
73.6
60.3
106.0
7.1
110.8 105.8 92.5
79.2
65.9
103.0
7.2
57.4
42.6
131.4
7.4
80.2
65.4
50.6
124.9
7.3
103.0 88.2
73.4
58.6
118.4
7.2
117.3 108.5 93.7
78.9
64.1
109.5
7.1
114.5 114.5 99.7
84.9
70.1
106.5
7.2
84.1
68.8
53.5
125.4
7.4
108.1 92.8
77.5
62.2
118.8
7.3
117.4 112.9 97.6
82.3
67.0
109.9
7.1
114.5 114.5 99.2
83.9
68.6
106.9
7.2
87.9
72.1
56.3
125.9
7.4
113.1 97.3
81.5
65.7
119.3
7.3
117.4 117.4 101.6 85.8
70.0
110.4
7.2
114.6 114.6 98.8
83.0
67.2
107.3
7.2
95°F
41.1
31.1
108.8
9.3
56.8
46.8
36.8
100.5
9.1
72.5
62.5
52.5
42.4
92.1
9.0
91.9
76.8
66.8
56.7
46.7
85.2
8.9
46.0
34.3
112.4
9.3
63.3
51.6
39.9
103.8
9.2
80.6
68.9
57.2
45.6
95.1
9.0
95.2
84.7
73.0
61.3
49.7
88.0
8.9
92.1
82.9
71.2
59.6
47.9
85.8
9.0
50.8
37.5
115.9
9.4
69.7
56.4
43.1
107.0
9.2
88.7
75.3
62.0
48.7
98.1
9.0
98.5
92.6
79.3
65.9
52.6
90.8
8.9
95.2
90.7
77.3
64.0
50.7
88.5
9.0
55.6
40.7
119.5
9.4
76.2
61.2
46.3
110.3
9.2
96.7
81.8
66.8
51.8
101.2
9.1
101.7 100.5 85.5
70.6
55.6
93.6
8.9
98.4
98.4
83.4
68.5
53.5
91.2
9.0
81.0
64.9
48.8
111.2
9.3
102.8 86.7
70.6
54.5
102.0
9.1
102.5 101.9 85.8
69.7
53.6
94.3
9.0
99.2
99.2
83.1
67.0
50.9
92.0
9.1
85.9
68.6
51.4
112.1
9.3
108.9 91.7
74.4
57.2
102.8
9.1
103.3 103.3 86.1
68.9
51.6
95.1
9.0
99.9
99.9
82.7
65.5
48.3
92.7
9.1

90
52.3
69.0
85.6
98.9
58.7
77.0
95.3
102.4
99.6
65.0
85.0
105.1
106.0
103.0
71.4
93.1
114.8
109.5
106.5
98.3
117.0
109.9
106.9
103.4
119.3
110.4
107.3
44.7
63.5
82.4
85.2
54.4
71.5
88.6
88.0
85.8
64.2
79.5
94.9
90.8
88.5
74.0
87.6
101.2
93.6
91.2
93.4
102.0
94.3
92.0
99.2
102.8
95.1
92.7

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
42.1
32.0
58.8
48.6
38.5
75.4
65.3
55.1
45.0
95.3
80.2
70.1
59.9
46.9
35.2
65.3
53.5
41.8
83.6
71.9
60.1
48.4
100.1 88.3
76.6
64.9
99.6
90.0
78.3
66.5
51.7
38.4
71.7
58.4
45.1
91.7
78.4
65.1
51.8
104.8 96.4
83.1
69.8
103.0 98.2
84.9
71.6
56.5
41.7
78.2
63.3
48.4
99.9
85.0
70.1
55.2
109.5 104.5 89.6
74.7
106.5 106.5 91.6
76.7
82.6
66.9
51.2
105.4 89.7
74.0
58.4
109.9 107.4 91.7
76.0
106.9 106.9 91.2
75.5
86.9
70.4
53.9
111.0 94.5
78.0
61.5
110.4 110.4 93.8
77.3
107.3 107.3 90.7
74.2
105°F
38.2
28.2
53.6
43.7
33.8
69.0
59.1
49.2
39.3
85.2
70.3
60.4
50.5
42.9
31.3
60.0
48.4
36.8
77.1
65.5
53.9
42.3
88.0
77.9
66.3
54.7
85.8
76.4
64.9
53.3
47.5
34.3
66.3
53.1
39.8
85.1
71.8
58.6
45.4
90.8
85.4
72.2
58.9
88.5
83.8
70.6
57.4
52.2
37.3
72.7
57.8
42.9
93.1
78.2
63.3
48.4
93.6
93.0
78.1
63.2
91.2
91.2
76.4
61.5
77.4
61.3
45.3
97.2
83.0
67.0
51.0
94.3
94.0
78.0
61.9
92.0
92.0
75.9
59.9
82.1
64.9
47.7
101.3 87.8
70.7
53.5
95.1
95.1
77.9
60.7
92.7
92.7
75.5
58.4

65
49.8
53.1
54.8
56.5
58.3
59.8
61.8
60.3
59.8
60.8
57.7
40.6
43.1
41.7
45.7
44.1
48.3
46.6
45.9
43.9
43.5
41.2

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR102 (8.5 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

102.2
93.5
84.8
78.5
105.2
96.2
87.3
80.8
79.6
108.2
99.0
89.8
83.1
81.8
111.2
101.7
92.3
85.4
84.1
102.6
93.0
86.1
84.8
103.4
93.8
86.8
85.5

10.3
10.1
10.0
9.9
10.4
10.2
10.0
9.9
10.0
10.4
10.2
10.0
9.9
10.0
10.4
10.2
10.0
9.9
10.0
10.3
10.1
10.0
10.1
10.3
10.1
10.0
10.1

39.0
60.2
81.3
78.5
51.2
68.1
85.0
80.8
79.6
63.4
76.0
88.6
83.1
81.8
75.7
84.0
92.3
85.4
84.1
89.7
93.0
86.1
84.8
95.4
93.8
86.8
85.5

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
35.2
25.4
95.6
11.4
50.4
40.6
30.8
86.5
11.1
65.5
55.8
46.0
36.2
77.4
10.9
78.5
63.8
54.0
44.2
34.4
71.8
10.8
39.7
28.3
98.0
11.4
56.6
45.2
33.7
88.7
11.2
73.5
62.0
50.6
39.1
79.4
11.0
80.8
71.0
59.6
48.1
36.6
73.6
10.9
79.6
69.9
58.5
47.0
35.5
73.3
11.0
44.3
31.1
100.5
11.4
62.9
49.7
36.6
90.9
11.2
81.5
68.3
55.2
42.1
81.4
11.0
83.1
78.2
65.1
51.9
38.8
75.4
10.9
81.8
77.0
63.9
50.7
37.6
75.1
11.0
48.8
34.0
102.9
11.4
69.1
54.3
39.5
93.1
11.2
89.5
74.6
59.8
45.0
83.3
11.0
85.4
85.4
70.6
55.8
41.0
77.3
10.9
84.1
84.1
69.3
54.5
39.6
77.0
11.0
73.7
57.7
41.8
93.9
11.3
91.6
79.3
63.3
47.4
84.0
11.1
86.1
86.1
70.1
54.2
38.2
77.9
11.0
84.8
84.8
68.8
52.8
36.9
77.6
11.1
78.3
61.1
44.0
94.7
11.4
93.8
84.0
66.9
49.7
84.7
11.1
86.8
86.8
69.7
52.6
35.4
78.6
11.1
85.5
85.5
68.3
51.2
34.1
78.2
11.2

90
36.2
56.8
77.4
71.8
49.9
64.7
79.4
73.6
73.3
63.7
72.5
81.4
75.4
75.1
77.4
80.4
83.3
77.3
77.0
86.0
84.0
77.9
77.6
91.6
84.7
78.6
78.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
31.0
22.6
47.1
37.5
27.8
62.1
52.4
42.7
33.1
71.8
57.3
47.7
38.0
36.6
25.3
53.3
41.9
30.6
70.0
58.6
47.3
35.9
73.6
64.2
52.8
41.5
73.3
63.4
52.1
40.7
42.3
28.0
59.5
46.4
33.4
77.9
64.8
51.8
38.7
75.4
71.0
58.0
44.9
75.1
70.2
57.1
44.1
47.9
30.7
65.6
50.9
36.1
83.3
71.1
56.3
41.6
77.3
77.3
63.1
48.4
77.0
77.0
62.2
47.5
70.1
54.1
38.2
84.0
75.6
59.7
43.8
77.9
77.9
62.3
46.4
77.6
77.6
61.7
45.8
74.5
57.4
40.3
84.7
80.2
63.1
46.0
78.6
78.6
61.5
44.4
78.2
78.2
61.2
44.1

65
28.3
30.1
29.3
31.9
31.0
33.6
32.7
30.5
29.8
27.3
27.0

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

85

528150-YTG-T-0514
ZR102 (8.5 Ton) Reheat
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

2125

2550

2975

3400

3825

4250

86

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

72.0
74.0
61.6
73.3
75.3
62.6
58.2
74.5
76.7
63.6
59.2
75.7
78.1
64.7
60.2
73.9
76.5
63.0
58.8
72.0
75.0
61.4
57.4

5.0
4.9
5.1
4.9
4.8
5.0
4.7
4.8
4.7
5.0
4.7
4.7
4.6
4.9
4.6
4.7
4.6
4.9
4.6
4.7
4.6
4.9
4.6

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

53.3
49.0
46.3
56.3
51.8
49.0
43.2
59.4
54.6
51.6
45.5
62.4
57.4
54.3
47.9
66.2
60.9
57.6
50.8
70.1
64.5
60.9
53.7

6.1
5.8
5.4
6.0
5.7
5.4
5.3
6.0
5.7
5.4
5.3
6.0
5.7
5.3
5.2
5.9
5.6
5.3
5.2
5.9
5.6
5.3
5.2

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
35°F
8.5
7.1
5.7
62.7
5.5
11.6
10.2
8.8
7.3
61.5
5.3
21.8
20.4
18.9
17.5
16.1
53.9
5.3
13.4
11.3
9.2
64.8
5.5
17.9
15.8
13.7
11.6
63.6
5.3
33.6
31.5
29.4
27.3
25.2
55.8
5.2
37.4
35.3
33.2
31.2
29.1
50.7
5.0
18.2
15.5
12.7
66.9
5.4
24.1
21.4
18.7
15.9
65.7
5.2
45.3
42.6
39.9
37.1
34.4
57.6
5.2
48.8
47.8
45.0
42.3
39.6
52.4
5.0
23.0
19.6
16.2
69.1
5.3
30.4
27.0
23.6
20.2
67.8
5.1
57.1
53.7
50.4
47.0
43.6
59.5
5.1
60.2
60.2
56.8
53.5
50.1
54.0
4.9
25.8
22.4
18.9
70.1
5.3
33.7
30.2
26.8
23.3
68.7
5.1
62.0
60.1
56.7
53.2
49.8
60.3
5.1
58.8
58.8
55.4
51.9
48.4
54.8
4.9
28.7
25.1
21.6
71.0
5.3
37.0
33.5
29.9
26.4
69.7
5.1
61.4
61.4
61.4
59.5
55.9
61.2
5.1
57.4
57.4
53.9
50.4
46.8
55.6
4.9
55°F
48.0
6.2
7.3
6.5
5.7
4.9
42.2
6.1
14.6
13.9
13.1
12.3
11.5
39.1
5.8
53.6
6.1
11.9
10.5
9.1
7.7
47.0
6.1
23.8
22.4
21.0
19.6
18.1
43.5
5.7
28.6
27.1
25.7
24.3
22.9
36.3
5.7
59.2
6.1
16.6
14.5
12.5
10.4
51.7
6.0
33.0
31.0
28.9
26.8
24.8
47.8
5.7
38.2
37.5
35.4
33.4
31.3
39.8
5.6
64.8
6.1
21.3
18.5
15.8
13.1
56.5
6.0
42.2
39.5
36.8
34.1
31.4
52.2
5.7
47.9
47.9
45.2
42.4
39.7
43.3
5.6
67.4
6.0
24.7
21.4
18.1
14.9
58.8
6.0
48.8
45.6
42.3
39.0
35.8
54.4
5.6
50.8
50.8
47.5
44.3
41.0
45.2
5.6
70.0
6.0
28.1
24.2
20.4
16.6
61.1
5.9
55.5
51.6
47.8
44.0
40.2
56.5
5.6
53.7
53.7
49.9
46.1
42.3
47.1
5.5

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
45°F
3.5
2.4
1.3
9.5
8.4
7.2
6.1
18.2
17.1
16.0
14.9
5.6
3.8
2.1
14.9
13.2
11.4
9.7
28.7
26.9
25.2
23.4
33.0
31.2
29.5
27.7
7.6
5.2
2.8
20.4
18.0
15.6
13.2
39.2
36.8
34.4
32.0
43.5
42.6
40.2
37.8
9.7
6.6
3.6
25.8
22.8
19.7
16.7
49.7
46.6
43.6
40.5
54.0
54.0
51.0
47.9
10.9
7.5
4.2
29.2
25.8
22.5
19.1
55.4
52.9
49.5
46.1
54.8
54.8
51.4
48.1
12.1
8.4
4.7
32.5
28.9
25.2
21.5
61.2
59.1
55.4
51.7
55.6
55.6
51.9
48.2
65°F
4.4
4.0
3.5
3.1
9.5
9.1
8.6
8.2
9.1
8.0
6.9
5.8
20.2
19.1
18.0
16.9
22.6
21.5
20.4
19.3
13.7
12.0
10.2
8.5
30.9
29.1
27.4
25.7
33.0
32.4
30.7
28.9
18.3
15.9
13.6
11.2
41.6
39.2
36.8
34.4
43.3
43.3
41.0
38.6
22.2
19.2
16.3
13.3
47.7
45.5
42.6
39.6
45.2
45.2
42.2
39.3
26.0
22.5
19.0
15.4
53.8
51.9
48.3
44.8
47.1
47.1
43.5
40.0

65
13.8
21.7
26.0
29.6
35.4
37.5
44.9
42.8
44.7
48.0
44.5
7.7
15.8
18.2
23.9
27.2
32.0
36.2
36.6
36.3
41.2
36.4

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR102 (8.5 Ton) Reheat (Continued)
Air on
Evaporator Coil
CFM

2125

2550

2975

3400

3825

4250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

42.8
35.4
31.9
50.9
42.1
38.0
29.4
59.1
48.9
44.0
34.1
67.2
55.6
50.1
38.8
68.6
56.7
51.1
39.6
69.9
57.8
52.1
40.4

6.3
6.5
6.2
6.2
6.4
6.1
6.1
6.2
6.4
6.1
6.0
6.2
6.3
6.0
6.0
6.1
6.3
6.0
5.9
6.1
6.3
5.9
5.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
37.6
6.4
1.6
1.5
1.4
1.2
28.6
6.8
4.4
4.3
4.2
4.1
4.0
24.7
6.5
48.3
6.4
6.2
5.4
4.7
3.9
37.3
6.8
16.6
15.8
15.0
14.3
13.5
32.5
6.5
16.6
15.8
15.0
14.3
13.5
22.5
6.4
58.9
6.3
10.8
9.4
8.0
6.6
46.0
6.7
28.7
27.3
25.9
24.5
23.1
40.2
6.4
27.7
27.3
25.9
24.5
23.1
28.4
6.4
69.6
6.3
15.4
13.3
11.3
9.2
54.7
6.7
40.9
38.8
36.8
34.7
32.6
48.0
6.4
38.8
38.8
36.8
34.7
32.6
34.3
6.3
69.7
6.2
19.7
17.0
14.4
11.7
54.6
6.6
46.5
45.5
42.8
40.1
37.5
47.9
6.3
39.6
39.6
36.9
34.3
31.6
34.0
6.3
69.8
6.2
24.0
20.8
17.5
14.2
54.5
6.6
52.1
52.1
48.8
45.6
42.3
47.7
6.3
40.4
40.4
37.1
33.9
30.6
33.7
6.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
3.3
2.9
2.5
2.0
13.0
12.5
12.1
11.6
10.6
10.1
9.7
9.3
7.9
6.8
5.7
4.6
26.6
25.5
24.4
23.3
22.4
22.2
21.1
20.0
12.5
10.7
9.0
7.3
40.2
38.5
36.7
35.0
34.3
34.3
32.6
30.8
17.2
14.9
12.5
10.2
45.3
45.4
43.1
40.7
34.0
34.0
31.6
29.3
22.0
19.0
16.0
13.1
47.7
47.7
47.7
46.4
33.7
33.7
30.7
27.8

65
11.2
8.8
22.2
19.0
33.3
29.1
38.3
26.9
43.4
24.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

87

528150-YTG-T-0514

ZR120 (10 Ton) Cooling
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

2500

3000

3500

4000

4500

5000

88

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

137.8
131.8
125.8
113.9
143.9
137.6
131.3
118.9
114.8
150.0
143.4
136.9
123.9
119.6
156.1
149.3
142.5
129.0
124.5
151.7
144.8
131.1
126.6
154.2
147.2
133.3
128.6

7.3
7.1
7.0
6.9
7.4
7.2
7.0
6.9
6.9
7.4
7.2
7.1
7.0
7.0
7.4
7.3
7.1
7.0
7.0
7.3
7.1
7.0
7.0
7.3
7.2
7.1
7.1

67.5
85.5
103.5
113.9
73.5
93.3
113.1
118.9
114.8
79.5
101.1
122.7
123.9
119.6
85.5
108.9
132.2
129.0
124.5
116.7
139.7
131.1
126.6
124.5
147.2
133.3
128.6

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

127.3
119.8
112.4
103.2
132.4
124.6
116.9
107.3
106.5
137.4
129.4
121.3
111.4
110.6
142.5
134.1
125.8
115.5
114.7
136.0
127.5
117.1
116.2
137.8
129.2
118.6
117.8

9.2
9.1
9.0
9.0
9.2
9.1
9.0
9.0
8.9
9.2
9.2
9.1
9.0
9.0
9.3
9.2
9.1
9.0
9.0
9.2
9.1
9.0
9.0
9.2
9.1
9.0
9.0

57.6
75.9
94.3
103.2
65.2
85.0
104.8
107.3
106.5
72.9
94.1
115.3
111.4
110.6
80.5
103.1
125.8
115.5
114.7
110.2
127.5
117.1
116.2
117.3
129.2
118.6
117.8

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
55.5
43.9
132.5
8.2
73.9
62.3
50.6
125.8
8.1
92.3
80.6
69.0
57.4
119.1
8.0
112.8 97.5
85.8
74.2
62.6
108.5
7.9
60.4
47.3
138.1
8.3
80.2
67.1
54.0
131.1
8.2
100.0 86.9
73.8
60.7
124.1
8.0
118.2 105.1 92.0
78.9
65.8
113.1
8.0
114.8 108.3 95.2
82.2
69.1
110.6
7.9
65.3
50.8
143.7
8.3
86.5
72.0
57.4
136.4
8.2
107.7 93.2
78.6
64.0
129.1
8.1
123.6 112.7 98.1
83.5
69.0
117.7
8.0
119.6 116.2 101.6 87.0
72.5
115.1
8.0
70.2
54.2
149.3
8.4
92.8
76.8
60.8
141.7
8.2
115.4 99.4
83.4
67.4
134.1
8.1
129.0 120.2 104.2 88.2
72.2
122.2
8.0
124.5 124.0 108.0 91.9
75.9
119.6
8.0
99.1
81.6
64.0
143.8
8.2
123.1 105.6 88.0
70.5
136.2
8.1
131.1 126.7 109.2 91.6
74.1
124.1
8.0
126.6 126.3 108.8 91.2
73.7
121.4
8.0
105.4 86.4
67.3
146.0
8.3
130.9 111.8 92.7
73.6
138.2
8.1
133.3 133.3 114.2 95.1
76.0
125.9
8.1
128.6 128.6 109.6 90.5
71.4
123.2
8.0
95°F
47.1
36.2
117.5
10.5
65.0
54.1
43.3
110.8
10.4
83.0
72.1
61.2
50.3
104.0
10.3
101.2 84.7
73.8
62.9
52.0
96.1
10.2
52.5
39.8
122.4
10.5
72.3
59.6
46.9
115.4
10.4
92.1
79.4
66.7
54.0
108.3
10.3
106.0 93.3
80.6
67.9
55.2
100.1
10.2
106.5 96.1
83.4
70.7
58.0
99.2
10.2
58.0
43.5
127.3
10.5
79.6
65.1
50.6
120.0
10.4
101.2 86.7
72.2
57.7
112.6
10.3
110.7 101.8 87.3
72.8
58.3
104.0
10.2
110.6 104.9 90.4
75.9
61.4
103.2
10.2
63.5
47.2
132.1
10.5
86.8
70.5
54.3
124.6
10.4
110.2 93.9
77.6
61.3
117.0
10.3
115.5 110.4 94.1
77.8
61.5
108.0
10.2
114.7 113.7 97.4
81.1
64.8
107.1
10.2
92.4
74.7
56.9
126.1
10.4
117.2 99.4
81.7
63.9
118.4
10.3
117.1 114.5 96.7
79.0
61.2
109.4
10.2
116.2 115.8 98.0
80.2
62.5
108.4
10.2
98.0
78.8
59.5
127.6
10.4
124.2 104.9 85.7
66.4
119.8
10.3
118.6 118.6 99.4
80.2
60.9
110.7
10.2
117.8 117.8 98.6
79.3
60.1
109.8
10.2

90
62.6
80.7
98.9
108.5
69.4
89.1
108.9
113.1
110.6
76.2
97.6
119.0
117.7
115.1
83.0
106.0
129.0
122.2
119.6
113.4
133.6
124.1
121.4
120.9
138.2
125.9
123.2
52.8
72.3
91.8
96.1
61.8
81.0
100.2
100.1
99.2
70.7
89.6
108.6
104.0
103.2
79.6
98.3
117.0
108.0
107.1
105.2
118.4
109.4
108.4
112.0
119.8
110.7
109.8

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
51.3
40.0
69.5
58.2
46.9
87.6
76.4
65.1
53.9
107.0 91.1
79.8
68.6
56.5
43.6
76.3
63.4
50.5
96.0
83.1
70.2
57.4
112.1 99.2
86.3
73.4
110.6 102.2 89.3
76.4
61.7
47.1
83.0
68.5
54.0
104.4 89.9
75.4
60.9
117.1 107.2 92.7
78.2
115.1 110.5 96.0
81.5
66.8
50.7
89.8
73.7
57.5
112.8 96.7
80.5
64.4
122.2 115.3 99.2
83.0
119.6 118.9 102.7 86.5
95.8
78.1
60.5
120.2 102.5 84.9
67.2
124.1 120.6 103.0 85.3
121.4 121.0 103.4 85.7
101.7 82.6
63.4
127.5 108.3 89.2
70.0
125.9 125.9 106.8 87.6
123.2 123.2 104.1 84.9
105°F
44.2
33.5
61.6
50.9
40.3
79.1
68.4
57.7
47.0
95.1
80.3
69.6
58.9
49.3
36.9
68.5
56.1
43.7
87.8
75.3
62.9
50.5
99.4
88.5
76.0
63.6
99.2
89.5
77.0
64.6
54.5
40.3
75.5
61.3
47.2
96.5
82.3
68.1
54.0
103.7 96.6
82.5
68.3
103.2 97.7
83.6
69.4
59.6
43.7
82.4
66.5
50.6
105.2 89.3
73.4
57.5
108.0 104.8 88.9
73.0
107.1 106.0 90.1
74.2
87.8
70.5
53.1
111.2 94.6
77.2
59.9
109.4 107.8 90.4
73.1
108.4 107.9 90.5
73.2
93.2
74.4
55.6
117.3 99.9
81.1
62.2
110.7 110.7 91.9
73.1
109.8 109.8 91.0
72.1

65
57.3
60.5
63.5
63.7
67.0
66.8
70.4
67.6
68.1
68.5
65.7
48.2
51.2
52.2
54.2
55.3
57.1
58.3
55.7
55.8
54.3
53.3

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR120 (10 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

107.7
101.7
95.6
89.0
112.4
106.1
99.8
92.8
91.9
117.1
110.6
104.0
96.7
95.7
121.8
115.0
108.2
100.6
99.6
116.2
109.3
101.7
100.6
117.5
110.5
102.7
101.7

11.9
11.7
11.6
11.4
11.8
11.7
11.5
11.3
11.4
11.8
11.7
11.5
11.3
11.4
11.8
11.6
11.5
11.3
11.4
11.6
11.5
11.3
11.4
11.7
11.5
11.3
11.4

48.1
68.7
89.3
89.0
58.3
76.9
95.6
92.8
91.9
68.5
85.2
101.9
96.7
95.7
78.7
93.4
108.2
100.6
99.6
100.1
109.3
101.7
100.6
106.8
110.5
102.7
101.7

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
41.3
30.8
98.0
13.2
58.2
47.7
37.3
92.6
13.0
75.1
64.6
54.2
43.7
87.3
12.8
89.0
75.9
65.4
54.9
44.4
81.8
12.6
46.1
34.0
102.5
13.1
64.8
52.6
40.5
96.9
13.0
83.4
71.3
59.1
47.0
91.3
12.8
92.8
83.7
71.5
59.4
47.2
85.6
12.5
91.9
82.8
70.7
58.5
46.4
84.6
12.7
51.0
37.2
107.0
13.1
71.4
57.5
43.7
101.2
12.9
91.8
77.9
64.1
50.3
95.3
12.7
96.7
91.5
77.6
63.8
50.0
89.4
12.5
95.7
90.5
76.7
62.9
49.1
88.3
12.6
55.8
40.3
111.5
13.0
77.9
62.5
47.0
105.4
12.8
100.1 84.6
69.1
53.6
99.3
12.7
100.6 99.3
83.8
68.3
52.8
93.1
12.4
99.6
98.3
82.8
67.3
51.8
92.0
12.6
83.2
66.2
49.3
106.4
12.9
105.3 89.7
72.8
55.8
100.2
12.7
101.7 101.0 84.1
67.1
50.2
94.0
12.4
100.6 100.0 83.1
66.1
49.2
92.9
12.6
88.4
70.0
51.6
107.3
12.9
110.5 94.8
76.4
58.1
101.1
12.7
102.7 102.7 84.4
66.0
47.6
94.8
12.5
101.7 101.7 83.3
65.0
46.6
93.7
12.7

90
43.3
65.1
86.8
81.8
54.8
72.9
91.0
85.6
84.6
66.3
80.8
95.2
89.4
88.3
77.8
88.6
99.3
93.1
92.0
95.1
100.2
94.0
92.9
101.5
101.1
94.8
93.7

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
38.4
28.1
54.8
44.5
34.3
71.2
60.9
50.6
40.4
81.8
71.4
61.2
50.9
42.9
31.1
61.0
49.2
37.3
79.1
67.2
55.4
43.5
85.6
78.9
67.0
55.1
84.6
76.2
64.3
52.4
47.5
34.0
67.3
53.8
40.3
87.1
73.6
60.1
46.6
89.4
86.3
72.8
59.3
88.3
83.4
69.9
56.4
52.0
36.9
73.5
58.4
43.3
95.0
79.9
64.8
49.7
93.1
93.1
78.6
63.5
92.0
90.5
75.4
60.3
78.5
62.0
45.5
99.3
84.8
68.3
51.8
94.0
94.0
77.7
61.2
92.9
92.1
75.6
59.1
83.6
65.6
47.7
101.1 89.8
71.8
53.9
94.8
94.8
76.8
58.9
93.7
93.7
75.7
57.8

65
40.6
43.2
40.5
45.8
42.9
48.4
45.3
44.7
42.5
40.9
39.8

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

89

528150-YTG-T-0514

ZR120 (10 Ton) Reheat
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

2500

3000

3500

4000

4500

5000

90

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

81.3
75.9
70.6
72.8
82.4
76.7
71.0
73.6
65.6
83.5
77.5
71.5
74.3
66.1
84.7
78.3
71.9
75.1
66.6
79.5
73.3
76.3
67.8
80.8
74.7
77.5
69.0

6.2
6.1
6.0
5.8
6.2
6.0
5.9
5.7
5.7
6.1
6.0
5.9
5.7
5.6
6.1
6.0
5.9
5.7
5.6
6.0
5.9
5.7
5.6
6.0
5.9
5.7
5.6

12.0
26.3
42.2
15.1
31.5
50.1
56.8
18.1
36.6
58.0
61.7
21.2
41.8
66.0
66.6
22.5
44.3
71.7
67.8
23.8
46.7
77.5
69.0

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

52.1
55.3
58.4
52.2
56.5
59.8
63.2
56.5
55.7
60.8
64.4
68.0
60.8
60.0
65.1
69.0
72.8
65.2
64.2
66.7
70.4
63.0
62.1
64.4
68.0
60.9
60.0

7.4
6.9
6.5
6.2
7.4
6.9
6.5
6.2
6.1
7.3
6.9
6.5
6.2
6.1
7.3
6.9
6.5
6.2
6.1
7.0
6.6
6.3
6.2
7.0
6.6
6.3
6.2

1.2
16.2
28.2
2.0
22.5
39.0
46.2
2.9
28.9
49.8
55.2
3.7
35.3
60.6
64.2
4.1
37.8
60.7
62.1
4.5
40.4
60.9
60.0

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
35°F
66.7
6.8
9.6
7.1
4.7
65.6
6.5
23.9
21.5
19.1
16.6
64.5
6.2
39.7
37.3
34.9
32.5
30.0
62.5
6.0
69.4
6.8
12.1
9.2
6.2
68.3
6.5
28.6
25.6
22.7
19.7
67.1
6.2
47.2
44.2
41.3
38.3
35.4
65.0
6.0
53.9
50.9
48.0
45.0
42.1
60.6
5.9
72.1
6.7
14.7
11.2
7.8
70.9
6.5
33.2
29.7
26.3
22.8
69.7
6.2
54.6
51.1
47.7
44.2
40.8
67.6
6.0
60.2
58.7
55.3
51.8
48.4
63.0
5.9
74.9
6.7
17.2
13.3
9.3
73.6
6.4
37.8
33.9
29.9
25.9
72.4
6.2
62.0
58.0
54.1
50.1
46.1
70.1
5.9
66.6
66.6
62.6
58.6
54.7
65.4
5.9
18.3
14.1
9.9
73.1
6.5
40.1
35.9
31.7
27.5
71.9
6.2
67.7
61.5
57.3
53.1
49.0
69.7
6.0
67.8
67.8
63.6
59.4
55.2
64.9
5.9
19.4
15.0
10.6
72.6
6.5
42.3
38.0
33.6
29.2
71.4
6.2
73.5
65.0
60.6
56.2
51.8
69.2
6.0
69.0
69.0
64.6
60.2
55.8
64.5
5.9
55°F
46.4
7.7
49.0
7.3
14.7
13.2
11.7
10.2
51.6
6.9
26.7
25.2
23.7
22.3
20.8
46.1
6.5
51.3
7.7
54.1
7.3
20.3
18.1
15.8
13.6
57.0
6.8
36.8
34.5
32.3
30.1
27.8
50.8
6.5
44.0
41.7
39.5
37.3
35.0
50.2
6.5
56.1
7.7
59.2
7.3
25.9
22.9
20.0
17.0
62.3
6.8
46.8
43.9
40.9
37.9
34.9
55.6
6.5
54.1
53.0
50.0
47.0
44.0
54.9
6.5
60.9
7.7
64.3
7.2
31.5
27.8
24.1
20.4
67.6
6.8
56.9
53.2
49.4
45.7
42.0
60.4
6.5
64.2
64.2
60.5
56.8
53.0
59.6
6.5
63.3
7.3
33.8
29.7
25.7
21.6
66.7
6.9
58.9
56.8
52.8
48.7
44.7
59.5
6.6
62.1
62.1
58.0
54.0
49.9
58.8
6.5
62.4
7.3
36.0
31.7
27.3
22.9
65.7
6.9
60.9
60.5
56.2
51.8
47.4
58.6
6.6
60.0
60.0
55.6
51.2
46.8
57.9
6.5

90
6.6
21.3
35.2
8.5
27.0
44.6
51.5
10.5
32.8
53.9
58.4
12.5
38.5
63.3
65.4
13.3
41.1
66.2
64.9
14.1
43.6
69.2
64.5
13.0
23.7
19.4
34.9
40.6
25.7
46.2
50.1
32.0
57.5
59.6
36.0
58.0
58.8
40.0
58.6
57.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
45°F
4.6
2.7
19.3
17.3
15.4
13.4
33.2
31.3
29.3
27.4
6.0
3.4
24.4
21.8
19.3
16.7
42.0
39.4
36.8
34.2
48.9
46.3
43.7
41.1
7.3
4.1
29.6
26.3
23.1
19.9
50.7
47.5
44.3
41.1
57.1
55.9
52.6
49.4
8.6
4.8
34.7
30.8
27.0
23.1
59.4
55.6
51.7
47.9
65.4
65.4
61.5
57.7
9.2
5.1
36.9
32.8
28.7
24.6
63.3
59.2
55.1
50.9
64.9
64.9
60.8
56.7
9.8
5.4
39.2
34.8
30.4
26.0
67.2
62.8
58.4
54.0
64.5
64.5
60.1
55.7
65°F
11.8
10.6
9.4
8.2
22.5
21.3
20.0
18.8
17.4
15.4
13.5
11.5
33.0
31.0
29.0
27.1
38.6
36.6
34.7
32.7
23.0
20.2
17.5
14.8
43.5
40.7
38.0
35.3
49.1
48.1
45.4
42.6
28.5
25.1
21.6
18.1
54.0
50.5
47.0
43.5
59.6
59.6
56.1
52.6
32.0
28.0
24.0
20.0
56.3
54.5
50.5
46.5
58.8
58.7
54.7
50.7
35.5
31.0
26.5
22.0
58.6
58.5
53.9
49.4
57.9
57.9
53.4
48.9

65
25.4
31.6
38.6
37.8
46.2
44.1
53.8
46.8
52.6
49.6
51.3
17.6
25.1
30.7
32.5
39.9
40.0
49.1
42.5
46.7
44.9
44.4

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR120 (10 Ton) Reheat (Continued)
Air on
Evaporator Coil
CFM

2500

3000

3500

4000

4500

5000

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

40.8
42.8
44.9
39.9
46.1
48.4
50.7
45.2
44.8
51.4
54.0
56.6
50.4
49.9
56.7
59.6
62.4
55.6
55.1
60.0
62.9
56.0
55.5
60.5
63.4
56.4
55.9

8.0
7.6
7.2
6.9
8.0
7.6
7.2
6.8
6.8
8.0
7.6
7.1
6.8
6.8
8.0
7.6
7.1
6.8
6.8
7.6
7.2
6.9
6.8
7.7
7.2
6.9
6.9

9.9
19.1
16.2
30.9
34.9
22.5
42.6
45.0
28.8
54.3
55.1
34.2
55.4
55.5
39.7
56.4
55.9

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
35.1
8.4
36.6
8.0
9.0
8.1
7.1
6.2
38.1
7.5
18.2
17.3
16.3
15.4
14.5
33.8
7.2
40.9
8.4
42.7
7.9
14.5
12.8
11.1
9.4
44.5
7.5
29.2
27.5
25.7
24.0
22.3
39.5
7.2
33.2
31.5
29.8
28.1
26.4
39.3
7.1
46.7
8.3
48.8
7.9
20.0
17.5
15.1
12.6
50.9
7.5
40.1
37.6
35.1
32.7
30.2
45.1
7.1
44.2
43.2
40.7
38.3
35.8
44.9
7.1
52.5
8.3
54.9
7.9
25.6
22.3
19.0
15.8
57.3
7.4
51.1
47.8
44.6
41.3
38.0
50.8
7.1
55.1
54.9
51.7
48.4
45.1
50.5
7.1
56.7
7.9
30.3
26.3
22.4
18.4
59.2
7.5
53.7
52.1
48.1
44.2
40.2
52.5
7.2
55.5
55.4
51.4
47.5
43.5
52.2
7.1
58.5
8.0
35.0
30.4
25.7
21.0
61.0
7.5
56.4
56.4
51.7
47.1
42.4
54.2
7.2
55.9
55.9
51.2
46.6
41.9
53.9
7.2

90
6.8
14.6
13.0
26.8
29.3
19.3
39.0
39.9
25.6
50.8
50.5
32.4
52.5
52.2
39.3
54.2
53.9

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
6.1
5.5
4.8
4.2
13.9
13.3
12.6
12.0
11.6
10.2
8.7
7.3
25.3
23.9
22.5
21.0
27.9
26.4
25.0
23.6
17.1
14.8
12.6
10.4
36.8
34.5
32.3
30.0
39.2
38.4
36.1
33.9
22.6
19.5
16.5
13.4
48.2
45.1
42.1
39.1
50.5
50.3
47.2
44.2
28.5
24.6
20.7
16.8
51.2
49.7
45.8
41.9
52.2
52.1
48.2
44.2
34.5
29.7
24.9
20.1
54.2
54.2
49.5
44.7
53.9
53.9
49.1
44.3

65
11.3
19.6
22.1
27.8
31.6
36.0
41.2
38.0
40.3
39.9
39.5

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

91

528150-YTG-T-0514

ZR150 (12.5 Ton) Cooling
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

3125

3750

4375

5000

5625

6250

92

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

190.5
180.7
171.0
158.6
199.8
189.6
179.4
166.3
154.4
209.1
198.4
187.7
174.1
161.6
218.4
207.3
196.1
181.8
168.8
211.2
199.9
185.3
172.0
215.2
203.6
188.8
175.3

9.0
9.2
9.3
9.1
9.2
9.3
9.4
9.2
9.2
9.3
9.4
9.6
9.4
9.3
9.4
9.6
9.7
9.5
9.5
9.6
9.7
9.5
9.5
9.5
9.7
9.5
9.4

87.6
111.5
135.4
158.6
94.7
119.8
145.0
166.3
154.4
101.9
128.2
154.5
174.1
161.6
109.0
136.6
164.1
181.8
168.8
148.0
179.4
185.3
172.0
159.4
194.6
188.8
175.3

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

180.0
165.1
150.2
137.5
188.2
172.7
157.1
143.8
139.4
196.5
180.3
164.0
150.1
145.5
204.8
187.8
170.9
156.4
151.6
193.2
175.8
160.9
156.0
198.6
180.7
165.4
160.3

11.9
11.8
11.7
11.5
12.0
11.9
11.7
11.6
11.6
12.0
11.9
11.8
11.6
11.7
12.1
12.0
11.9
11.7
11.7
12.0
11.9
11.7
11.7
12.0
11.9
11.7
11.8

75.6
99.3
123.0
137.5
83.2
109.0
134.8
143.8
139.4
90.7
118.6
146.6
150.1
145.5
98.3
128.3
158.4
156.4
151.6
138.6
169.6
160.9
156.0
148.9
180.7
165.4
160.3

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
73.4
59.1
185.2
10.5
97.2
83.0
68.8
172.9
10.5
121.1 106.9 92.7
78.4
160.6
10.5
158.6 158.6 150.5 136.2 122.0
148.0
10.3
78.6
62.4
194.0
10.6
103.7 87.5
71.3
181.1
10.6
128.8 112.6 96.4
80.3
168.3
10.6
166.3 166.3 157.9 141.8 125.6
155.1
10.4
154.4 148.9 132.7 116.6 100.4
146.9
10.4
83.8
65.7
202.8
10.7
110.1 92.0
73.9
189.3
10.7
136.4 118.3 100.2 82.1
175.9
10.7
174.1 174.1 165.4 147.3 129.2
162.1
10.5
161.6 156.6 138.5 120.4 102.3
153.5
10.5
89.0
68.9
211.6
10.8
116.5 96.5
76.5
197.5
10.8
144.1 124.1 104.0 84.0
183.5
10.8
181.8 181.8 172.9 152.9 132.8
169.1
10.6
168.8 164.4 144.3 124.3 104.2
160.2
10.6
126.6 105.3 83.9
202.2
10.8
156.7 135.4 114.0 92.7
187.8
10.8
185.3 185.3 169.5 148.2 126.8
173.1
10.6
172.0 169.8 148.5 127.1 105.8
164.0
10.6
136.7 114.0 91.4
206.9
10.8
169.4 146.7 124.0 101.4
192.2
10.8
188.8 188.8 166.2 143.5 120.9
177.1
10.6
175.3 175.3 152.6 130.0 107.3
167.8
10.6
95°F
61.3
46.9
168.2
13.3
85.0
70.6
56.3
153.8
13.2
108.6 94.3
80.0
65.6
139.5
13.0
133.0 114.6 100.2 85.9
71.5
127.9
12.9
67.2
51.2
175.5
13.3
93.0
77.0
60.9
160.6
13.2
118.8 102.8 86.7
70.7
145.6
13.1
140.8 124.8 108.8 92.8
76.8
133.5
12.9
139.4 125.8 109.8 93.8
77.7
130.3
13.0
73.0
55.4
182.9
13.4
101.0 83.3
65.6
167.3
13.3
128.9 111.2 93.5
75.8
151.8
13.1
148.6 135.1 117.4 99.7
82.0
139.2
13.0
145.5 136.1 118.4 100.7 83.1
135.7
13.0
78.9
59.6
190.3
13.4
109.0 89.6
70.2
174.1
13.3
139.0 119.6 100.3 80.9
157.9
13.2
156.4 145.3 126.0 106.6 87.2
144.8
13.0
151.6 146.4 127.1 107.7 88.4
141.2
13.1
117.4 96.2
75.1
178.5
13.3
149.7 128.5 107.3 86.1
161.8
13.2
160.9 155.4 134.2 113.0 91.8
148.4
13.0
156.0 153.4 132.2 111.0 89.8
144.7
13.1
125.9 102.9 79.9
182.8
13.3
160.4 137.4 114.4 91.4
165.8
13.2
165.4 165.4 142.4 119.4 96.4
152.0
13.0
160.3 160.3 137.3 114.3 91.3
148.3
13.1

90
81.6
105.4
129.2
148.0
89.0
114.4
139.9
155.1
146.9
96.3
123.4
150.6
162.1
153.5
103.6
132.4
161.2
169.1
160.2
143.3
174.5
173.1
164.0
154.1
187.7
177.1
167.8
71.8
95.1
118.4
127.9
79.5
104.5
129.4
133.5
130.3
87.3
113.9
140.5
139.2
135.7
95.1
123.3
151.6
144.8
141.2
133.3
158.7
148.4
144.7
143.3
165.8
152.0
148.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
67.3
53.0
91.1
76.8
62.5
114.9 100.6 86.3
72.0
148.0 139.6 125.3 111.1
72.9
56.8
98.3
82.2
66.1
123.8 107.7 91.6
75.5
155.1 149.5 133.4 117.3
146.9 137.3 121.2 105.2
78.4
60.5
105.5 87.6
69.7
132.7 114.8 96.9
79.0
162.1 159.3 141.4 123.5
153.5 146.4 128.5 110.6
83.9
64.2
112.7 93.0
73.3
141.5 121.8 102.1 82.4
169.1 169.1 149.4 129.7
160.2 155.4 135.7 116.0
122.0 100.8 79.5
153.2 131.9 110.7 89.4
173.1 173.1 151.9 130.6
164.0 161.6 140.3 119.1
131.3 108.5 85.6
164.9 142.0 119.2 96.4
177.1 177.1 154.3 131.5
167.8 167.8 145.0 122.1
105°F
58.0
43.9
81.0
66.9
52.8
103.9 89.8
75.7
61.6
125.7 110.1 96.0
81.9
63.7
47.8
88.6
72.8
56.9
113.6 97.7
81.9
66.0
132.1 119.8 104.0 88.1
130.3 117.1 101.2 85.4
69.3
51.7
96.3
78.7
61.0
123.3 105.6 88.0
70.4
138.4 129.5 111.9 94.3
135.7 126.6 109.0 91.3
75.0
55.6
104.0 84.6
65.2
132.9 113.6 94.2
74.8
144.8 139.2 119.8 100.4
141.2 136.1 116.7 97.3
112.3 91.2
70.2
143.5 122.5 101.5 80.4
148.4 145.6 124.6 103.5
144.7 142.2 121.1 100.1
120.6 97.9
75.2
154.1 131.4 108.7 86.1
152.0 152.0 129.3 106.6
148.3 148.3 125.6 102.9

65
96.8
101.2
89.1
105.6
92.7
110.0
96.3
109.3
97.8
108.6
99.3
67.8
72.2
69.5
76.6
73.7
81.1
77.9
82.5
79.1
84.0
80.2

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR150 (12.5 Ton) Cooling (Continued)
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

90

77
72
67
62
77
72
67
62
57
77
72
67
62
57
77
72
67
62
57
72
67
62
57
72
67
62
57

156.3
142.6
128.8
118.4
162.8
148.5
134.1
123.3
121.1
169.3
154.4
139.5
128.2
126.0
175.8
160.3
144.9
133.1
130.8
163.7
147.9
135.9
133.5
167.0
150.9
138.6
136.2

14.6
14.5
14.4
14.2
14.7
14.6
14.4
14.3
14.3
14.7
14.6
14.5
14.3
14.4
14.8
14.7
14.5
14.4
14.4
14.7
14.5
14.4
14.4
14.7
14.5
14.4
14.4

67.9
90.8
113.7
118.4
75.9
100.0
124.1
123.3
121.1
83.9
109.2
134.5
128.2
126.0
91.9
118.4
144.9
133.1
130.8
128.0
147.9
135.9
133.5
137.7
150.9
138.6
136.2

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
115°F
54.8
40.9
144.5
16.0
77.0
63.1
49.3
131.3
15.9
99.1
85.3
71.5
57.6
118.1
15.7
118.4 105.7 91.8
78.0
64.1
108.8
15.6
60.2
44.5
150.2
16.0
84.3
68.6
52.9
136.4
15.9
108.4 92.7
77.0
61.3
122.7
15.8
123.3 114.8 99.1
83.4
67.7
113.0
15.6
121.1 108.4 92.7
77.0
61.3
112.0
15.7
65.6
48.0
155.8
16.1
91.6
74.1
56.5
141.5
16.0
117.6 100.1 82.5
65.0
127.2
15.8
128.2 124.0 106.4 88.8
71.3
117.3
15.7
126.0 117.1 99.5
81.9
64.4
116.2
15.7
71.0
51.6
161.4
16.2
98.9
79.5
60.1
146.6
16.0
126.9 107.5 88.1
68.6
131.8
15.9
133.1 133.1 113.7 94.3
74.9
121.5
15.7
130.8 125.7 106.3 86.9
67.5
120.4
15.8
107.1 86.2
65.3
148.9
16.0
137.4 116.5 95.6
74.7
133.9
15.9
135.9 135.9 115.0 94.1
73.2
123.4
15.7
133.5 131.0 110.1 89.2
68.3
122.3
15.8
115.3 92.9
70.5
151.2
16.0
147.9 125.5 103.1 80.7
135.9
15.8
138.6 138.6 116.3 93.9
71.5
125.3
15.7
136.2 136.2 113.9 91.5
69.1
124.2
15.7

90
60.9
86.6
110.3
108.8
72.3
95.5
118.8
113.0
112.0
83.6
104.5
127.2
117.3
116.2
95.0
113.4
131.8
121.5
120.4
122.7
133.9
123.4
122.3
132.0
135.9
125.3
124.2

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
125°F
51.5
37.9
73.0
59.4
45.8
94.4
80.8
67.2
53.6
108.8 102.4 87.6
74.0
56.7
41.2
80.0
64.4
48.9
103.2 87.7
72.1
56.6
113.0 109.8 94.3
78.7
112.0 99.7
84.2
68.6
61.9
44.4
87.0
69.5
52.0
112.0 94.5
77.0
59.5
117.3 117.3 100.9 83.4
116.2 107.5 90.0
72.6
67.0
47.6
93.9
74.5
55.1
120.8 101.4 82.0
62.5
121.5 121.5 107.6 88.1
120.4 115.4 95.9
76.5
102.0 81.2
60.4
131.3 110.5 89.7
69.0
123.4 123.4 105.4 84.6
122.3 119.8 99.0
78.3
110.0 87.9
65.8
135.9 119.6 97.5
75.4
125.3 125.3 103.2 81.1
124.2 124.2 102.1 80.0

65
60.4
63.2
53.1
65.9
55.1
68.7
57.0
63.9
57.5
59.0
58.0

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

93

528150-YTG-T-0514

ZR150 (12.5 Ton) Reheat
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

3125

3750

4375

5000

5625

6250

94

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

87.0
84.6
82.9
89.0
86.5
84.8
82.2
90.9
88.4
86.6
84.0
92.8
90.3
88.5
85.9
94.1
91.5
89.7
87.1
95.4
92.8
91.0
88.3

7.7
7.3
7.3
7.4
7.1
7.1
7.7
7.2
6.9
6.8
7.4
6.9
6.6
6.6
7.1
7.5
7.1
7.1
7.7
8.0
7.7
7.6
8.3

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

84.8
81.9
78.7
88.8
85.8
82.5
76.1
92.8
89.7
86.2
79.5
96.8
93.6
89.9
83.0
99.3
96.0
92.2
85.1
101.8
98.4
94.6
87.2

8.9
8.7
8.2
8.6
8.3
7.8
8.7
8.2
8.0
7.5
8.3
7.8
7.6
7.1
8.0
8.2
8.0
7.5
8.4
8.6
8.4
7.9
8.8

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
35°F
6.6
4.8
3.1
85.9
8.3
14.4
12.7
11.0
9.2
83.3
8.0
20.3
18.6
16.9
15.2
13.5
80.8
7.7
11.5
9.2
6.9
88.9
8.0
26.3
24.0
21.7
19.5
86.2
7.7
36.7
34.4
32.1
29.8
27.5
83.6
7.4
43.1
40.9
38.6
36.3
34.0
79.1
8.2
16.4
13.5
10.7
91.8
7.7
38.3
35.4
32.5
29.7
89.1
7.4
53.1
50.2
47.4
44.5
41.6
86.4
7.2
63.2
60.0
57.1
54.2
51.4
81.8
7.9
21.3
17.9
14.4
94.8
7.4
50.2
46.8
43.3
39.9
91.9
7.1
69.5
66.0
62.6
59.1
55.7
89.2
6.9
83.2
79.1
75.6
72.2
68.7
84.4
7.6
15.2
12.5
9.9
96.7
7.8
35.5
32.8
30.2
27.5
93.8
7.6
48.0
45.4
42.7
40.1
37.4
91.0
7.3
58.0
55.0
52.4
49.7
47.1
86.1
8.0
9.1
7.2
5.4
98.6
8.3
20.7
18.9
17.0
15.2
95.6
8.0
26.6
24.7
22.9
21.0
19.2
92.8
7.8
32.9
31.0
29.2
27.3
25.5
87.8
8.5
55°F
4.6
2.9
1.2
84.2
9.3
9.3
7.6
5.9
4.2
79.1
8.9
15.1
13.4
11.7
10.0
8.3
74.6
8.4
9.9
7.4
5.0
87.3
9.2
21.9
19.4
16.9
14.5
82.0
8.8
36.5
34.1
31.6
29.1
26.7
77.4
8.3
38.4
36.0
33.5
31.0
28.6
72.6
9.0
15.2
11.9
8.7
90.4
9.1
34.4
31.2
27.9
24.7
85.0
8.7
58.0
54.7
51.5
48.3
45.0
80.2
8.2
60.7
57.8
54.6
51.3
48.1
75.2
8.9
20.5
16.5
12.4
93.5
9.0
47.0
42.9
38.9
34.9
87.9
8.6
79.4
75.4
71.4
67.4
63.4
83.0
8.1
83.0
79.6
75.6
71.6
67.6
77.8
8.8
17.4
13.6
9.8
97.7
9.2
39.3
35.5
31.8
28.0
91.8
8.8
66.2
62.4
58.7
54.9
51.1
86.6
8.3
69.3
65.9
62.1
58.4
54.6
81.2
9.0
14.3
10.8
7.3
101.9
9.5
31.7
28.1
24.6
21.1
95.7
9.1
53.0
49.4
45.9
42.4
38.8
90.3
8.6
55.7
52.2
48.7
45.1
41.6
84.7
9.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
45°F
5.6
3.9
2.2
11.8
10.1
8.4
6.7
17.7
16.0
14.3
12.6
10.7
8.3
5.9
24.1
21.7
19.3
17.0
36.6
34.2
31.9
29.5
40.8
38.4
36.0
33.7
15.8
12.7
9.7
36.3
33.3
30.2
27.2
55.5
52.5
49.4
46.4
61.9
58.9
55.8
52.8
20.9
17.2
13.4
48.6
44.9
41.1
37.4
74.5
70.7
67.0
63.3
83.1
79.4
75.6
71.9
16.3
13.1
9.9
37.4
34.2
31.0
27.8
57.1
53.9
50.7
47.5
63.7
60.5
57.3
54.1
11.7
9.0
6.3
26.2
23.5
20.8
18.1
39.8
37.1
34.4
31.7
44.3
41.6
38.9
36.2
65°F
10.4
8.9
7.3
5.8
24.9
23.4
21.8
20.3
18.2
16.0
13.9
11.8
40.0
37.9
35.8
33.7
44.1
42.0
39.9
37.8
25.9
23.2
20.5
17.8
55.1
52.4
49.8
47.1
60.3
57.7
55.1
52.4
1.1
33.6
30.4
27.1
23.8
70.3
67.0
63.7
60.4
76.4
73.5
70.2
66.9
31.7
28.3
25.0
21.6
69.4
66.0
62.6
59.3
72.7
70.3
66.9
63.6
29.8
26.3
22.8
19.4
68.5
65.0
61.6
58.1
68.9
67.1
63.7
60.2

65
10.9
27.1
31.3
43.3
49.7
59.5
68.2
44.3
50.8
29.0
33.5
18.7
31.5
35.6
44.4
49.7
57.2
63.7
55.9
60.2
54.6
56.8

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR150 (12.5 Ton) Reheat (Continued)
Air on
Evaporator Coil
CFM

3125

3750

4375

5000

5625

6250

WB
(°F)

Total
Capacity1
(MBh)

Total
Input
(kW)2

72
67
62
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57

83.6
76.2
70.5
85.8
78.2
72.3
69.0
88.0
80.2
74.2
70.8
90.1
82.2
76.0
72.6
96.1
87.6
81.0
77.3
102.0
93.0
86.0
82.1

9.7
9.2
8.7
9.9
9.3
8.8
9.3
10.0
9.4
8.9
9.5
10.1
9.5
9.0
9.6
10.3
9.6
9.1
9.7
10.4
9.8
9.2
9.8

Temperature of Air on Condenser Coil
Sensible Capacity (MBh)
Total
Total
Return Dry Bulb (°F)
Capacity1
Input
(MBh)
(kW)2
85
80
75
70
65
75°F
83.0
10.2
11.5
10.1
8.7
7.3
73.4
9.4
34.8
33.4
32.0
30.6
29.2
66.4
8.9
84.3
10.5
14.5
12.7
10.9
9.1
74.4
9.7
43.6
41.8
40.0
38.2
36.4
67.3
9.3
49.8
48.1
46.3
44.5
42.7
65.5
9.7
85.5
10.9
17.4
15.2
13.1
10.9
75.5
10.1
52.3
50.2
48.0
45.8
43.7
68.2
9.6
59.9
57.7
55.5
53.4
51.2
66.4
10.0
86.8
11.3
20.3
17.8
15.2
12.7
76.5
10.5
61.1
58.5
56.0
53.5
50.9
69.1
10.0
69.9
67.3
64.8
62.3
59.7
67.4
10.4
94.4
11.3
24.1
21.1
18.1
15.2
83.4
10.5
72.5
69.6
66.6
63.7
60.7
75.4
9.9
76.0
74.7
71.8
68.8
65.8
73.4
10.4
102.0
11.3
27.8
24.5
21.1
17.7
90.3
10.4
84.0
80.6
77.2
73.8
70.5
81.7
9.9
82.1
82.1
78.7
75.3
71.9
79.5
10.3

Sensible Capacity (MBh)
Return Dry Bulb (°F)
85
80
75
70
85°F
12.6
11.4
10.1
8.8
44.7
43.4
42.1
40.9
10.8
9.3
7.9
6.4
47.1
45.6
44.2
42.7
55.5
54.1
52.7
51.2
8.9
7.2
5.6
4.0
49.5
47.9
46.2
44.6
59.4
57.6
56.0
54.4
7.0
5.2
3.4
1.6
51.9
50.1
48.3
46.5
63.3
61.2
59.4
57.6
16.4
13.9
11.3
8.8
75.4
73.1
70.6
68.0
73.4
73.4
73.4
73.4
25.9
22.6
19.3
16.0
81.7
81.7
81.7
81.7
79.5
79.5
79.5
79.5

65
39.6
41.3
49.8
43.0
52.8
44.7
55.8
65.5
71.5
81.7
79.5

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

Johnson Controls Unitary Products

95

528150-YTG-T-0514
Drive Selection
1.

Determine side or bottom supply duct Application.

2.

Determine desired airflow.

3.

Calculate or measure the amount of external static pressure.
• Add or deduct any additional static resistance from “Additional Static Resistance Table”.

4.

Using the operating point determined from steps 1, 2 & 3, locate this point on the appropriate supply air blower performance
table. (Linear interpolation may be necessary.)

5.

Noting the RPM and BHP from step 4, locate the appropriate motor and, or drive on the RPM selection table.

6.

Review the BHP compared to the motor options available. Select the appropriate motor and, or drive.

7.

Review the RPM range for the motor options available. Select the appropriate drive if multiple drives are available for the
chosen motor.

8.

Determine turns open to obtain the desired operation point.

Example
1.

2600 CFM

2.

1.6 iwg

3.

Using the supply air blower performance table below, the following data point was located: 1268 RPM & 1.95 BHP.

4.

Using the RPM selection table below, Size X and Model Y is found.

5.

1.95 BHP exceeds the maximum continuous BHP rating of the 1.5 HP motor. The 2 HP motor is required.

6.

1268 RPM is within the range of the 2 HP drives.

7.

Using the 2 HP motor and drive, .5 turns open will achieve 1268 RPM.

Airflow Performance
Example Supply Air Blower Performance
Air Flow
(CFM)
2200
2400
2600
2800

Available External Static Pressure - IWG
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
804
835
869
906

0.50
0.66
0.84
1.03

1.5 HP & Field Supplied Drive
866
0.71
925
0.90
982
897
0.87
956
1.06 1013
931
1.05
990
1.24 1047
968
1.25 1027 1.43 1084

1.06
1.22
1.40
1.60

1038
1069
1103
1139

Standard 1.5 HP & Drive
1.21 1092 1.35 1147
1.37 1124 1.51 1178
1.55 1158 1.69 1212
1.75 1194 1.89 1249

1.48
1.64
1.82
2.02

1203
1234
1268
1304

Alternate 2 HP & Drive
1.61 1259 1.73 1317
1.77 1290 1.90 1348
1.95 1324 2.07 1382
2.14 1361 2.27
-

1.87
2.03
2.21
-

Example RPM Selection
Size
(Tons)

Model

X

Y

Airflow
Option
Std.
H. Static

HP
1.5
2

Max
BHP
1.73
2.30

Motor
Sheave
1VM50
1VM50

Blower
Sheave
AK74
AK64

6 Turns
Open
N/A
N/A

5 Turns
Open
897
1039

4 Turns
Open
945
1094

3

6

0.00
0.00
0.01
0.01
0.01

0.00
0.00
0.01
0.01
0.01

3 Turns
Open
991
1150

2 Turns
Open
1035
1207

1 Turn
Open
1079
1256

Fully
Closed
1126
1308

Example Additional Static Resistance
Size
(Tons)

X

96

Model

Y

CFM Cooling Only
900
1000
1100
1200
1300

0.05
0.05
0.04
0.04
0.03

Economizer

4” Pleated Filter

-0.05
-0.03
-0.02
0.00
0.01

0.01
0.02
0.03
0.04
0.05

Electric Heat kW
9
15
0.00
0.00
0.01
0.01
0.01

0.01
0.02
0.02
0.02
0.03

20

24

0.01
0.02
0.02
0.02
0.03

0.01
0.02
0.02
0.02
0.03

Johnson Controls Unitary Products

528150-YTG-T-0514
Altitude and Temperature Correction for CFM, Static
Pressure and Power.

use the indoor blower tables for high altitude applications,
certain corrections are necessary.

The information below should be used to assist in application of
product when being applied at altitudes at or exceeding 1000
feet above sea level.

A centrifugal fan is a "constant volume" device. This means
that, if the rpm remains constant, the CFM delivered is the
same regardless of the density of the air. However, since the air
at high altitude is less dense, less static pressure will be
generated and less power will be required than a similar
application at sea level. Air density correction factors are shown
in Table 14 and Figure 27.

The air flow rates listed in the standard blower performance
tables are based on standard air at sea level. As the altitude or
temperature increases, the density of air decreases. In order to
Altitude/Temperature Correction Factors
Air
Temp.
40
50
60
70
80
90
100

0
1.060
1.039
1.019
1.000
0.982
0.964
0.946

1000
1.022
1.002
0.982
0.964
0.947
0.929
0.912

2000
0.986
0.966
0.948
0.930
0.913
0.897
0.880

3000
0.950
0.931
0.913
0.896
0.880
0.864
0.848

4000
0.916
0.898
0.880
0.864
0.848
0.833
0.817

Altitude (Ft.)
5000
0.882
0.864
0.848
0.832
0.817
0.802
0.787

6000
0.849
0.832
0.816
0.801
0.787
0.772
0.758

7000
0.818
0.802
0.787
0.772
0.758
0.744
0.730

8000
0.788
0.772
0.757
0.743
0.730
0.716
0.703

9000
0.758
0.743
0.729
0.715
0.702
0.689
0.676

10000
0.729
0.715
0.701
0.688
0.676
0.663
0.651

1.100
1.050

Correction Factor

1.000
Sea Level

0.950

1000 ft

0.900

2000 ft

0.850

3000 ft

0.800

5000 ft

0.750

6000 ft
7000 ft

4000 ft

8000 ft

0.700

9000 ft
10000 ft

0.650
0.600
40

50

60

70

80

90

100

Air Temperature (ºF)
The examples below will assist in determining the airflow
performance of the product at altitude.

blower tables to select the blower speed and the BHP
requirement.

Example 1: What are the corrected CFM, static pressure, and
BHP at an elevation of 5,000 ft. if the blower performance data
is 6,000 CFM, 1.5 IWC and 4.0 BHP?

Solution: As in the example above, no temperature
information is given so 70°F is assumed.

Solution: At an elevation of 5,000 ft. the indoor blower will still
deliver 6,000 CFM if the rpm is unchanged. However, Table 13
must be used to determine the static pressure and BHP. Since
no temperature data is given, we will assume an air temperature
of 70°F. Table 15 shows the correction factor to be 0.832.
Corrected static pressure = 1.5 x 0.832 = 1.248 IWC
Corrected BHP = 4.0 x 0.832 = 3.328
Example 2: A system, located at 5,000 feet of elevation, is to
deliver 6,000 CFM at a static pressure of 1.5". Use the unit
Johnson Controls Unitary Products

The 1.5" static pressure given is at an elevation of 5,000 ft. The
first step is to convert this static pressure to equivalent sea level
conditions.
Sea level static pressure = 1.5 / .832 = 1.80"
Enter the blower table at 6000 sCFM and static pressure of
1.8". The rpm listed will be the same rpm needed at 5,000 ft.
Suppose that the corresponding BHP listed in the table is 3.2.
This value must be corrected for elevation.
BHP at 5,000 ft. = 3.2 x .832 = 2.66
97

528150-YTG-T-0514

Indoor Blower Specifications
Motor

Airflow
Size
Model
Option
(Tons)
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)

ZH
ZH
ZH
ZH
ZH
ZH
ZH
ZH
ZJ
ZJ
ZJ
ZJ
ZJ
ZJ
ZJ
ZJ
ZR
ZR
ZR
ZR
ZR
ZR
ZR
ZR

Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static

HP

RPM

Eff.

SF

1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
1-1/2
2
1-1/2
3
2
3
2
3
3
5
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
1-1/2
2
1-1/2
3
2
3
2
3
3
5
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
1-1/2
2
1-1/2
3
2
3
2
3
3
5

1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725
1725

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.87
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.87
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.87

1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15

Motor Sheave
Datum Dia.
Bore (in.)
Frame
(in.)
56
2.0 - 3.0
7/8
56
3.0 - 4.0
7/8
56
2.0 - 3.0
7/8
56
3.0 - 4.0
7/8
56
2.6 - 3.6
7/8
56
4.2 - 5.2
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
184T
4.3 - 5.3
1-1/8
56
2.0 - 3.0
7/8
56
3.0 - 4.0
7/8
56
2.0 - 3.0
7/8
56
3.0 - 4.0
7/8
56
2.6 - 3.6
7/8
56
4.2 - 5.2
7/8
56
2.6 - 3.6
7/8
56
3.6 - 4.6
7/8
56
2.6 - 3.6
7/8
56
3.6 - 4.6
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
184T
4.3 - 5.3
1-1/8
56
1.2 - 2.9
7/8
56
3.0 - 4.0
7/8
56
1.2 - 2.9
7/8
56
3.0 - 4.0
7/8
56
1.2 - 2.9
7/8
56
3.0 - 4.0
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
56
3.4 - 4.4
7/8
184T
4.3 - 5.3
1-1/8

Model
1VM34
1VL44
1VM34
1VL44
1VL40
1VP56
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VP56
1VM34
1VL44
1VM34
1VL44
1VL40
1VP56
1VL40
1VM50
1VL40
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VP56
1VP34
1VL44
1VP34
1VL44
1VP34
1VL44
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VP56

Blower Sheave
Datum Dia.
Bore (in.)
(in.)
6.5
1
6.5
1
5.2
1
5.2
1
5.7
1
7.0
1
7.0
1
6.0
1
7.0
1
5.7
1
9.0
1
7.0
1
8.0
1
7.0
1
7.0
1
6.7
1
6.5
1
6.5
1
5.2
1
5.2
1
5.7
1
7.0
1
7.0
1
7.0
1
6.5
1
6.5
1
8.5
1
7.0
1
8.0
1
7.0
1
7.0
1
6.7
1
5.7
1
5.5
1
5.7
1
5.5
1
5.7
1
5.5
1
7.0
1
6.0
1
7.0
1
5.7
1
8.5
1
7.0
1
8.0
1
7.0
1
7.0
1
6.7
1

Model
AK69
AK69
AK56
AK56
AK61
AK74
AK74
AK64
AK74
AK61
AK94
AK74
AK84
AK74
AK74
BK77
AK69
AK69
AK56
AK56
AK61
AK74
AK74
AK74
AK69
AK69
AK89
AK74
AK84
AK74
AK74
BK77
AK61
AK59
AK61
AK59
AK61
AK59
AK74
AK64
AK74
AK61
AK89
AK74
AK84
AK74
AK74
BK77

Belt
A47
A47
A47
A47
A47
A51
A49
A49
A49
A49
A56
A54
A56
A54
A54
BX55
A47
A47
A47
A47
A47
A51
A53
A54
A52
A54
A56
A54
A56
A54
A54
BX55
A47
A47
A47
A47
A47
A47
A49
A49
A49
A49
A56
A54
A56
A54
A54
BX55

Power Exhaust Specifications
Model

Voltage

2PE04703225
2PE04703246
2PE04703258

208/230-1-60
460-1-60
575-1-60

HP
3/4
3/4
3/4

Motor
RPM1
1075
1075
1050

QTY
1
1
1

LRA
7.8
3.4
2.9

Motor
FLA
5
2.2
1.5

MCA
6.3
2.8
1.9

Fuse Size
10
5
4

CFM @
0.1 ESP
3800
3800
3800

1. Motors are multi-tapped and factory wired for high speed.

98

Johnson Controls Unitary Products

528150-YTG-T-0514

RPM Selection
Size
(Tons)
037
(3)

Model
ZH

049
(4)

ZH

061
(5)

ZH

078
(6.5)

ZH

090
(7.5)

ZH

102
(8.5)

ZH

120
(10)

ZH

150
(12.5)

ZH

037
(3)

ZJ

049
(4)

ZJ

061
(5)

ZJ

078
(6.5)

ZJ

090
(7.5)

ZJ

102
(8.5)

ZJ

120
(10)

ZJ

150
(12.5)

ZJ

037
(3.0)

ZR

049
(4.0)

ZR

061
(5.0)

ZR

078
(6.5)

ZR

090
(7.5)

ZR

102
(8.5)

ZR

120
(10)

ZR

150
(12.5)

ZR

Airflow
Option
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.

1.5
1.5
1.5
1.5
1.5
2
1.5
2
1.5
3
2
3
2
3
3
5
1.5
1.5
1.5
1.5
1.5
2
1.5
2
1.5
3
2
3
2
3
3
5
1.5

Max
BHP
1.5
1.5
1.5
1.5
1.5
2
1.73
2.30
1.73
3.45
2.30
3.45
2.30
3.45
3.45
5.75
1.5
1.5
1.5
1.5
1.5
2
1.73
2.30
1.73
3.45
2.30
3.45
2.30
3.45
3.45
5.75
1.5

H. Static

1.5

1.5

1VL44

AK59

N/A

Std.

1.5

1.5

1VP34

AK61

N/A

H. Static

1.5

1.5

1VL44

AK59

N/A

Std.

1.5

1.5

1VP34

AK61

N/A

HP

Motor
Sheave
1VM34
1VL44
1VM34
1VL44
1VL40
1VP56
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VP56
1VM34
1VL44
1VM34
1VL44
1VL40
1VP56
1VL40
1VM50
1VL40
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VP56
1VP34

Blower
Sheave
AK69
AK69
AK56
AK56
AK61
AK74
AK74
AK64
AK74
AK61
AK94
AK74
AK84
AK74
AK74
BK77
AK69
AK69
AK56
AK56
AK61
AK74
AK74
AK74
AK69
AK69
AK89
AK74
AK84
AK74
AK74
BK77
AK61

6 Turns
Open
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1052
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1052
N/A

5 Turns
Open
531
796
663
995
787
1035
887
1039
887
1088
690
887
776
887
887
1095
531
796
663
995
787
1035
641
887
690
955
731
887
776
887
887
1095
575

4 Turns
Open
584
849
730
1062
847
1084
936
1094
936
1147
728
936
819
936
936
1136
584
849
730
1062
847
1084
690
936
743
1008
771
936
819
936
936
1136
636

3 Turns
Open
637
902
796
1128
908
1134
986
1150
986
1205
767
986
863
986
986
1175
637
902
796
1128
908
1134
739
986
796
1062
812
986
863
986
986
1175
696

2 Turns
Open
690
955
863
1194
968
1183
1035
1207
1035
1265
805
1035
906
1035
1035
1216
690
955
863
1194
968
1183
789
1035
849
1115
852
1035
906
1035
1035
1216
757

1 Turn
Open
743
1008
929
1261
1029
1232
1084
1256
1084
1312
843
1084
949
1084
1084
1272
743
1008
929
1261
1029
1232
838
1084
902
1168
893
1084
949
1084
1084
1272
817

Fully
Closed
796
1062
995
1327
1089
1281
1134
1308
1134
1365
882
1134
992
1134
1134
N/A
796
1062
995
1327
1089
1281
887
1134
955
1221
934
1134
992
1134
1134
N/A
878

878

941

1004

1066

1129

1192

575

636

696

757

817

878

878

941

1004

1066

1129

1192

575

636

696

757

817

878

H. Static

2

2

1VL44

AK59

N/A

878

941

1004

1066

1129

1192

Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static
Std.
H. Static

1.5
2
1.5
3
2
3
2
3
3
5

1.73
2.30
1.73
3.45
2.30
3.45
2.30
3.45
3.45
5.75

1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VM50
1VP56

AK74
AK64
AK74
AK61
AK89
AK74
AK84
AK74
AK74
BK77

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1052

897
1039
897
1088
735
880
785
880
880
1095

945
1094
945
1147
775
928
821
928
928
1136

991
1150
991
1205
815
972
858
972
972
1175

1035
1207
1035
1265
851
1016
901
1016
1016
1216

1079
1256
1079
1312
889
1067
940
1067
1067
1272

1126
1308
1126
1365
930
1110
980
1110
1110
N/A

Johnson Controls Unitary Products

99

528150-YTG-T-0514

Additional Static Resistance - ZH037 thru 061
Size
(Tons)

Model

037 (3)
049 (4)

ZH

061 (5)

ZH

CFM Cooling Only1 Economizer2 3 4” Pleated Filter2
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

0.05
0.05
0.04
0.04
0.03
0.03
0.03
0.02
0.02
0.01
0.01
0.00
-0.01
-0.01
-0.01
-0.02
-0.02
-0.02
-0.03
-0.03
-0.04
-0.04
-0.05

-0.05
-0.03
-0.02
0.00
0.01
0.03
0.04
0.06
0.07
0.08
0.10
0.11
0.13
0.14
0.15
0.16
0.17
0.18
0.19
0.20
0.21
0.22
0.23

0.01
0.02
0.03
0.04
0.05
0.07
0.08
0.09
0.10
0.11
0.13
0.14
0.07
0.08
0.08
0.09
0.10
0.10
0.11
0.12
0.12
0.13
0.14

3

6

0.00
0.00
0.01
0.01
0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.06
0.07
0.08

0.00
0.00
0.01
0.01
0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.06
0.07
0.08

Electric Heat kW2
9
15
0.00
0.00
0.01
0.01
0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.06
0.07
0.08

0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.07
0.04
0.04
0.05
0.05
0.06
0.07
0.07
0.08
0.09
0.10
0.11

20

24

0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.07
0.04
0.04
0.05
0.05
0.06
0.07
0.07
0.08
0.09
0.10
0.11

0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.07
0.04
0.04
0.05
0.05
0.06
0.07
0.07
0.08
0.09
0.10
0.11

1. Add these values to the available static resistance in the respective Blower Performance Tables.
2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables.
3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct
is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

Additional Static Resistance - ZJ/ZR037 thru 061
Size
(Tons)

Model

037 (3)

ZJ/ZR

049 (4)
061 (5)

ZJ/ZR

CFM Cooling Only1 Economizer2 3 4” Pleated Filter2
900
1000
1100
1200
1300
1400
1500
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

0.05
0.05
0.04
0.04
0.03
0.03
0.03
-0.01
-0.01
-0.01
-0.01
-0.01
-0.01
-0.02
-0.02
-0.02
-0.03
-0.03
-0.04
-0.04
-0.05

-0.05
-0.03
-0.02
0.00
0.01
0.03
0.04
0.10
0.11
0.12
0.13
0.14
0.15
0.16
0.17
0.18
0.19
0.20
0.21
0.22
0.23

0.01
0.02
0.03
0.04
0.05
0.07
0.08
0.05
0.06
0.06
0.07
0.08
0.08
0.09
0.10
0.10
0.11
0.12
0.12
0.13
0.14

3

6

0.00
0.00
0.01
0.01
0.01
0.02
0.02
0.01
0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.06
0.07
0.08

0.00
0.00
0.01
0.01
0.01
0.02
0.02
0.01
0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.06
0.07
0.08

Electric Heat kW2
9
15
0.00
0.00
0.01
0.01
0.01
0.02
0.02
0.01
0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.06
0.07
0.08

0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.02
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.07
0.07
0.08
0.09
0.10
0.11

20

24

0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.02
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.07
0.07
0.08
0.09
0.10
0.11

0.01
0.02
0.02
0.02
0.03
0.03
0.04
0.02
0.03
0.03
0.04
0.04
0.05
0.05
0.06
0.07
0.07
0.08
0.09
0.10
0.11

1. Add these values to the available static resistance in the respective Blower Performance Tables.
2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables.
3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct
is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

100

Johnson Controls Unitary Products

528150-YTG-T-0514

Additional Static Resistance - ZH/ZR078 thru 150
Size
(Tons)

078 (6.5)
090 (7.5)

102 (8.5)
120 (10)
150 (12.5)

Model

CFM

Cooling Only1

Economizer2 3

4” Filter2

ZHZR

1900
2100
2300
2500
2700
2900
3100
3300
3500
3700
3900
4100
4300
4500

0.00
-0.01
-0.01
-0.02
-0.03
-0.04
-0.05
-0.06
-0.07
-0.08
-0.09
-0.09
-0.10
-0.11

0.07
0.09
0.11
0.13
0.16
0.18
0.20
0.22
0.24
0.27
0.29
0.31
0.30
0.35

1900

0.06

2100

0.07

2300

0.08

2500

0.09

2700

0.11

2900

0.12

3100

0.14

3300

0.16

3500

0.18

3700

0.20

3900

0.23

4100

0.25

4300

0.28

4500

0.30

4700

0.33

4900

0.36

5100

0.39

5300

0.42

5500

0.45

5700

0.48

5900

0.52

6100

0.56

6300

0.60

0.02
0.02
0.04
0.11
0.18
0.25
0.31
0.37
0.43
0.49
0.54
0.58
0.65
0.69
0.74
0.78
0.82
0.86
0.89
0.93
0.96
0.98
1.01

ZH/ZR

Electric Heat kW2
24
36

09

18

0.10
0.11
0.12
0.14
0.15
0.16
0.18
0.19
0.20
0.21
0.23
0.24
0.25
0.26

0.05
0.06
0.07
0.08
0.09
0.10
0.12
0.13
0.15
0.17
0.19
0.21
0.23
0.25

0.06
0.07
0.08
0.09
0.10
0.11
0.13
0.14
0.16
0.18
0.20
0.22
0.24
0.26

0.07
0.08
0.09
0.10
0.12
0.13
0.15
0.17
0.19
0.21
0.23
0.25
0.28
0.30

0.08
0.09
0.10
0.11
0.13
0.14
0.16
0.18
0.20
0.22
0.24
0.26
0.29
0.31

0.10
0.11
0.13
0.14
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37

54

0.12

0.05

0.06

0.07

0.08

0.10

0.13

0.06

0.07

0.08

0.09

0.11

0.14

0.07

0.08

0.09

0.10

0.13

0.16

0.08

0.09

0.10

0.11

0.14

0.17

0.09

0.10

0.12

0.13

0.16

0.19

0.10

0.11

0.13

0.14

0.18

0.20

0.12

0.13

0.15

0.16

0.20

0.22

0.13

0.14

0.17

0.18

0.22

0.25

0.15

0.16

0.19

0.20

0.24

0.27

0.17

0.18

0.21

0.22

0.26

0.29

0.19

0.20

0.23

0.24

0.28

0.32

0.21

0.22

0.25

0.26

0.31

0.35

0.23

0.24

0.28

0.29

0.34

0.38

0.25

0.26

0.30

0.31

0.37

0.41

0.28

0.29

0.33

0.34

0.40

0.44

0.30

0.31

0.35

0.37

0.43

0.47

0.33

0.34

0.38

0.40

0.46

0.51

0.35

0.37

0.41

0.43

0.49

0.56

0.38

0.40

0.44

0.46

0.53

0.58

0.41

0.43

0.47

0.49

0.56

0.62

0.44

0.46

0.50

0.53

0.59

0.67

0.47

0.49

0.53

0.56

0.62

0.71

0.50

0.53

0.56

0.59

0.65

1. Add these values to the available static resistance in the respective Blower Performance Tables.
2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables.
3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct
is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

Johnson Controls Unitary Products

101

528150-YTG-T-0514

Additional Static Resistance - ZJ078-150
Size
(Tons)

078 (6.5)
090 (7.5)
102 (8.5)
120 (10)
150 (12.5)

Model

CFM

Cooling Only1

Economizer2,3

4” Filter2

ZJ

1900
2100
2300
2500
2700
2900
3100
3300
3500
3700
3900
4100
4300
4500
4700
4900
5100
5300
5500
5700
5900
6100
6300

0.06
0.07
0.08
0.09
0.11
0.12
0.14
0.16
0.18
0.20
0.23
0.25
0.28
0.30
0.33
0.36
0.39
0.42
0.45
0.48
0.52
0.56
0.60

0.02
0.02
0.04
0.11
0.18
0.25
0.31
0.37
0.43
0.49
0.54
0.58
0.65
0.69
0.74
0.78
0.82
0.86
0.89
0.93
0.96
0.98
1.01

0.12
0.13
0.14
0.16
0.17
0.19
0.20
0.22
0.26
0.27
0.29
0.32
0.35
0.38
0.41
0.44
0.47
0.51
0.55
0.58
0.62
0.67
0.71

Electric Heat kW2
24
36

9

18

0.05
0.06
0.07
0.08
0.09
0.10
0.12
0.13
0.15
0.17
0.19
0.21
0.23
0.25
0.28
0.30
0.33
0.35
0.38
0.41
0.44
0.47
0.50

0.06
0.07
0.08
0.09
0.10
0.11
0.13
0.14
0.16
0.18
0.20
0.22
0.24
0.26
0.29
0.31
0.34
0.37
0.40
0.43
0.46
0.49
0.53

0.07
0.08
0.09
0.10
0.12
0.13
0.15
0.17
0.19
0.21
0.23
0.25
0.28
0.30
0.33
0.35
0.38
0.41
0.44
0.47
0.50
0.53
0.56

0.08
0.09
0.10
0.11
0.13
0.14
0.16
0.18
0.20
0.22
0.24
0.26
0.29
0.31
0.34
0.37
0.40
0.43
0.46
0.49
0.53
0.56
0.59

54
0.10
0.11
0.13
0.14
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.40
0.43
0.46
0.49
0.53
0.56
0.59
0.62
0.65

1. Add these values to the available static resistance in the respective Blower Performance Tables.
2. Deduct these values from the available external static pressure shown in the respective Blower Performance Tables.
3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct is
less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

102

Johnson Controls Unitary Products

528150-YTG-T-0514

Gas Heat Minimum Supply Air
Size
(Tons)

Model

037
(3)

ZH/ZJ/ZR

049
(4)

ZH/ZJ/ZR

061
(5)

ZH/ZJ/ZR

078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)

ZH/ZJ/ZR
ZH/ZJ/ZR
ZH/ZJ/ZR
ZH/ZJ/ZR
ZH/ZJ/ZR

Supply Air (CFM)
Heating
Min
Max
890
2220
915
2370
1130
1800
890
2220
915
2370
1290
2250
915
2370
1380
2570
1580
2630
1950
3250
1950
3250
2250
3750
2250
3750
2550
4250
2550
4250
3000
5000
3000
5000
3750
6250
3750
6250

Heat Size
A05 / N05
A07 / N07
A09 / N09
A05 / N05
A07 / N07
A09 / N09
A07 / N07
A09 / N09
A13 / N13
10
15
10
15
10
15
15
20
15
20

Electric Heat Minimum Supply Air
3 thru 5 Tons
Size
(Tons)

Model

037
(3)

ZH/ZJ/ZR

049
(4)

ZH/ZJ/ZR

061
(5)

ZH/ZJ/ZR

Voltage
208/230-3-60
460-3-60
600-3-60
208/230-3-60
460-3-60
600-3-60
208/230-3-60
460-3-60
600-3-60

Minimum Supply Air (CFM)
Heater kW
9
15
1020
1020
960
960
960
960
1420
1420
1400
1400
1400
1400
1600
1600
1600
1600
1600
1600

3
960
980
-

6
960
960
1280
1400
1600
1600
-

9
1950
1950
1950
2250
2250
2250
2550
2550
2550
-

Minimum Supply Air (CFM)
Heater kW
18
24
36
1950
1950
1950
1950
1950
1950
1950
1950
1950
2250
2250
2250
2250
2250
2250
2250
2250
2250
2550
2550
2550
2550
2550
2550
2550
2550
2550
3000
3000
3000
3000
3000
3000
3000
3000
3000
3750
3750
3750
3750
3750
3750
3750
3750
3750

20
1420
1400
1400
1600
1600
1600

24
1600
1600
1600

6-1/2 thru 12-1/5 Tons
Size
(Tons)

Model

078
(6.5)

ZH/ZJ/ZR

090
(7.5)

ZH/ZJ/ZR

102
(8.5)

ZH/ZJ/ZR

120
(10)

ZH/ZJ/ZR

150
(12.5)

ZH/ZJ/ZR

Johnson Controls Unitary Products

Voltage
208/230-3-60
460-3-60
600-3-60
208/230-3-60
460-3-60
600-3-60
208/230-3-60
460-3-60
600-3-60
208/230-3-60
460-3-60
600-3-60
208/230-3-60
460-3-60
600-3-60

54
3500
3000
3500
4000
3750
3750

103

528150-YTG-T-0514

Airflow Performance
ZH037-150 Side Duct Application
ZH037 (3.0 Ton) Side Duct
Air Flow
(CFM)
900
1000
1100
1200
1300
1400
1500

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
560
582
601
620
638
655
673

0.29
0.29
0.30
0.32
0.35
0.39
0.43

Standard 1.5 HP & Drive
628
0.35
695
0.42
650
0.34
716
0.42
670
0.35
736
0.43
688
0.37
754
0.45
706
0.40
772
0.48
724
0.44
790
0.51
741
0.48
807
0.56

760
781
801
819
837
855
872

0.51
0.51
0.52
0.54
0.57
0.60
0.65

823
845
864
883
901
918
936

0.61
0.61
0.62
0.64
0.67
0.70
0.75

Hi Static 1.5 HP & Drive
886
0.72
949
0.82
908
0.71
970
0.82
927
0.72
990
0.83
946
0.74 1008 0.85
964
0.77 1026 0.88
981
0.81 1044 0.91
999
0.85 1061 0.96

1011
1032
1052
1070
1088
1106
1124

0.92 1073 1.01 1136
0.92 1095 1.01 1158
0.93 1114 1.02 1177
0.95 1133 1.04 1196
0.98 1151 1.06 1214
1.01 1168 1.10 1231
1.06 1186 1.15 1249
1.5 HP & Field Supplied Drive

1.09
1.08
1.09
1.11
1.14
1.18
1.22

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH049 (4.0 Ton) Side Duct
Air Flow
(CFM)
1200
1300
1400
1500
1600
1700
1800
1900
2000

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
620
0.32
638
0.35
655
0.39
673
0.43
691
0.48
709
0.54
728
0.60
747
0.67
766
0.75

688
706
724
741
759
777
796
815
834

0.37
0.40
0.44
0.48
0.54
0.59
0.66
0.73
0.80

754
772
790
807
825
843
862
881
901

Standard 1.5 HP & Drive
0.45
819
0.54
883
0.48
837
0.57
901
0.51
855
0.60
918
0.56
872
0.65
936
0.61
890
0.70
954
0.67
908
0.76
972
0.73
927
0.82
991
0.80
946
0.89 1010
0.87
966
0.96 1029

0.64
0.67
0.70
0.75
0.80
0.86
0.92
0.99
1.06

946
964
981
999
1017
1035
1053
1073
1092

0.74
0.77
0.81
0.85
0.90
0.96
1.03
1.09
1.17

1008
1026
1044
1061
1079
1097
1116
1135
1155

0.85
0.88
0.91
0.96
1.01
1.07
1.13
1.20
1.27

Hi Static 1.5 HP & Drive
1070 0.95 1133 1.04
1088 0.98 1151 1.06
1106 1.01 1168 1.10
1124 1.06 1186 1.15
1141 1.11 1204 1.20
1160 1.17 1222 1.26
1178 1.23 1241 1.32
1197 1.30 1260 1.39
1217 1.37 1279 1.46

1196
1214
1231
1249
1267
1285
1303
1323
-

1.11
1.14
1.18
1.22
1.27
1.33
1.39
1.46
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZH061 (5.0 Ton) Side Duct
Air Flow
(CFM)

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive

1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

1.
2.
3.
4.

104

659
675
691
707
724
741
759
778
797
817
838

0.35
0.38
0.42
0.47
0.53
0.59
0.65
0.73
0.81
0.90
1.00

719
735
751
767
784
801
819
838
857
877
898

0.46
0.50
0.54
0.58
0.64
0.70
0.77
0.84
0.92
1.01
1.11

780
796
812
829
846
863
881
900
919
939
960

Hi Static 2 HP & Drive

Standard 1.5 HP & Drive
0.57
0.60
0.64
0.69
0.75
0.81
0.87
0.95
1.03
1.12
1.22

843
859
875
891
908
925
943
962
981
1002
1022

0.67
0.71
0.75
0.79
0.85
0.91
0.98
1.05
1.13
1.22
1.32

905
920
936
953
970
987
1005
1024
1043
1063
1084

0.77
0.81
0.85
0.90
0.95
1.01
1.08
1.15
1.23
1.32
1.42

964
980
996
1012
1029
1047
1065
1083
1103
1123
1144

0.87
0.91
0.95
0.99
1.05
1.11
1.18
1.25
1.33
1.42
1.52

1020
1036
1052
1069
1085
1103
1121
1139
1159
1179
1200

0.97
1.01
1.05
1.09
1.15
1.21
1.28
1.35
1.43
1.52
1.62

1071
1087
1103
1120
1137
1154
1172
1191
1210
1230
1251

1.07
1.11
1.15
1.20
1.25
1.31
1.38
1.45
1.53
1.62
1.72

1116
1132
1148
1165
1182
1199
1217
1236
1255
1275
1296

1.17 1154
1.21 1170
1.25 1186
1.30 1202
1.35 1219
1.41 1236
1.48 1254
1.56 1273
1.64 1292
1.73 1312
1.82 1333
FS4

1.28
1.32
1.36
1.41
1.46
1.52
1.59
1.66
1.74
1.83
1.93

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH078 (6.5 Ton) Side Duct
Air Flow
(CFM)
1800
2000
2200
2400
2600
2800
3000
3200
3400

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
751
776
804
835
869
906
945
987
1030

Field Supplied Drive
0.22
813
0.43
872
0.35
838
0.56
897
0.50
866
0.71
925
0.66
897
0.87
956
0.84
931
1.05
990
1.03
968
1.25 1027
1.25 1007 1.46 1066
1.48 1048 1.69 1107
1.73 1092 1.94 1151

0.62
0.75
0.90
1.06
1.24
1.43
1.65
1.88
2.12

929
954
982
1013
1047
1084
1123
1165
1208

0.78
0.92
1.06
1.22
1.40
1.60
1.81
2.04
2.29

Standard 1.5 HP & Drive
985
0.93 1040 1.07
1010 1.07 1064 1.20
1038 1.21 1092 1.35
1069 1.37 1124 1.51
1103 1.55 1158 1.69
1139 1.75 1194 1.89
1179 1.96 1234 2.10
1220 2.19
-

1095
1119
1147
1178
1212
1249
1288
-

1.20
1.33
1.48
1.64
1.82
2.02
2.23
-

1150
1175
1203
1234
1268
1304
-

Hi Static 2 HP & Drive
1.33 1206 1.46 1265
1.46 1231 1.59 1289
1.61 1259 1.73 1317
1.77 1290 1.90 1348
1.95 1324 2.07 1382
2.14 1361 2.27
2 HP & Field Supplied Drive

1.59
1.72
1.87
2.03
2.21
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH090 (7.5 Ton) Side Duct
Air Flow
(CFM)
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
776
0.35
838
0.56
804
0.50
866
0.71
835
0.66
897
0.87
869
0.84
931
1.05
906
1.03
968
1.25
945
1.25 1007 1.46
987
1.48 1048 1.69
1030 1.73 1092 1.94
1076 1.99 1138 2.20
1124 2.27 1185 2.48

897
925
956
990
1027
1066
1107
1151
1197
1245

0.75
0.90
1.06
1.24
1.43
1.65
1.88
2.12
2.39
2.67

954
982
1013
1047
1084
1123
1165
1208
1254
1302

Standard 1.5 HP & Drive
0.92 1010 1.07 1064
1.06 1038 1.21 1092
1.22 1069 1.37 1124
1.40 1103 1.55 1158
1.60 1139 1.75 1194
1.81 1179 1.96 1234
2.04 1220 2.19 1275
2.29 1264 2.44 1319
2.56 1310 2.71 1364
2.84 1357 2.99 1412

1.20
1.35
1.51
1.69
1.89
2.10
2.33
2.58
2.84
3.12

1119
1147
1178
1212
1249
1288
1330
1374
1419
1467

Hi Static 3 HP & Drive
1.33 1175 1.46 1231 1.59 1289
1.48 1203 1.61 1259 1.73 1317
1.64 1234 1.77 1290 1.90 1348
1.82 1268 1.95 1324 2.07 1382
2.02 1304 2.14 1361 2.27 1419
2.23 1344 2.36 1400 2.48 1458
2.46 1385 2.59 1442 2.71 1500
2.71 1429 2.84 1485 2.96 1544
2.97 1475 3.10 1531 3.23 1589
3.25 1522 3.38
3 HP & Field Supplied Drive

1.72
1.87
2.03
2.21
2.40
2.62
2.85
3.10
3.36
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH102 (8.5 Ton) Side Duct
Air Flow
(CFM)
2600
2800
3000
3200
3400
3600
3800
4000
4200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
628
0.56
678
0.76
648
0.67
698
0.87
666
0.80
717
1.00
684
0.95
735
1.15
702
1.11
753
1.31
721
1.28
772
1.48
742
1.47
793
1.67
765
1.67
815
1.86
789
1.87
840
2.07

730
750
768
786
804
824
844
867
891

Standard 2 HP & Drive
0.93
781
1.09
833
1.04
801
1.20
853
1.17
820
1.33
871
1.32
838
1.48
889
1.48
856
1.64
907
1.65
875
1.81
927
1.84
896
2.00
947
2.04
918
2.19
970
2.24
943
2.40
995

1.25
1.36
1.49
1.63
1.79
1.97
2.15
2.35
2.56

883
903
922
940
958
977
998
1020
1045

1.41
1.52
1.65
1.80
1.96
2.13
2.32
2.51
2.72

933
953
971
989
1007
1027
1047
1070
1094

Hi Static 3 HP & Drive
1.59
980
1.80 1025 2.05 1068
1.70 1000 1.91 1046 2.16 1088
1.83 1019 2.04 1064 2.29 1106
1.98 1037 2.19 1082 2.44 1124
2.14 1055 2.35 1100 2.60 1142
2.31 1074 2.52 1119 2.77
2.50 1095 2.71 1140 2.96
2.70 1117 2.91
2.90
3 HP & Field Supplied Drive

2.35
2.46
2.59
2.74
2.90
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

105

528150-YTG-T-0514

ZH120 (10 Ton) Side Duct
Air Flow
(CFM)
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
675
0.53
726
0.74
686
0.63
738
0.84
699
0.75
750
0.96
713
0.88
764
1.09
728
1.02
779
1.23
745
1.18
796
1.39
763
1.36
815
1.57
783
1.55
835
1.76
805
1.77
856
1.98
828
2.00
879
2.21
852
2.25
904
2.46
879
2.52
930
2.73
906
2.81
958
3.02

776
787
800
814
829
846
864
884
906
929
953
980
1007

0.94
1.04
1.16
1.28
1.43
1.59
1.76
1.96
2.17
2.41
2.66
2.93
3.22

824
835
847
861
877
893
912
932
953
976
1001
1027
1055

Standard 2 HP & Drive
1.12
870
1.30
914
1.23
881
1.41
925
1.34
893
1.52
938
1.47
907
1.65
952
1.61
923
1.79
967
1.77
939
1.95
984
1.95
958
2.13 1002
2.15
978
2.33 1022
2.36
999
2.54 1044
2.59 1022 2.77 1067
2.85 1047 3.03 1092
3.12 1073 3.30
3.41
-

1.48
1.58
1.70
1.83
1.97
2.13
2.31
2.50
2.72
2.95
3.20
-

957
969
981
995
1010
1027
1046
1066
1087
1110
1135
-

Hi Static 3 HP & Drive
1.65 1000 1.82 1041 1.99 1082
1.76 1011 1.93 1052 2.10 1093
1.87 1024 2.04 1065 2.21 1106
2.00 1037 2.17 1079 2.34 1119
2.14 1053 2.31 1094 2.48 1135
2.30 1069 2.47 1111 2.64 1152
2.48 1088 2.65 1129 2.82 1170
2.67 1108 2.84 1149 3.02 1190
2.89 1129 3.06 1171 3.23 1211
3.12 1152 3.29
3.37
3 HP & Field Supplied Drive

2.17
2.27
2.39
2.52
2.66
2.82
3.00
3.19
3.41
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH150 (12.5 Ton) Side Duct
Air Flow
(CFM)
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
713
728
745
763
783
805
828
852
879
906
936
966
999
1032
1067
1103

0.88
1.02
1.18
1.36
1.55
1.77
2.00
2.25
2.52
2.81
3.12
3.45
3.80
4.16
4.54
4.94

Field Supplied Drive
764
1.09
814
1.28
779
1.23
829
1.43
796
1.39
846
1.59
815
1.57
864
1.76
835
1.76
884
1.96
856
1.98
906
2.17
879
2.21
929
2.41
904
2.46
953
2.66
930
2.73
980
2.93
958
3.02 1007 3.22
987
3.33 1037 3.53
1018 3.66 1067 3.86
1050 4.01 1100 4.20
1084 4.37 1133 4.57
1119 4.75 1168 4.95
1155 5.15 1204 5.34
Hi Static 5 HP & Drive

861
877
893
912
932
953
976
1001
1027
1055
1084
1115
1147
1181
1216
1252

1.47
1.61
1.77
1.95
2.15
2.36
2.59
2.85
3.12
3.41
3.72
4.05
4.39
4.75
5.13
5.53

907
923
939
958
978
999
1022
1047
1073
1101
1130
1161
1193
1227
1262
1298

1.65
1.79
1.95
2.13
2.33
2.54
2.77
3.03
3.30
3.59
3.90
4.23
4.57
4.93
5.31
5.71

952
967
984
1002
1022
1044
1067
1092
1118
1146
1175
1206
1238
1271
1306
-

1.83
1.97
2.13
2.31
2.50
2.72
2.95
3.20
3.47
3.76
4.07
4.40
4.75
5.11
5.49
-

Standard 3 HP & Drive
995
2.00 1037 2.17
1010 2.14 1053 2.31
1027 2.30 1069 2.47
1046 2.48 1088 2.65
1066 2.67 1108 2.84
1087 2.89 1129 3.06
1110 3.12 1152 3.29
1135 3.37 1177 3.54
1161 3.65 1203 3.82
1189 3.94 1231 4.11
1218 4.24 1260 4.42
1249 4.57 1291 4.74
1281 4.92 1323 5.09
1315 5.28 1357 5.45
1350 5.66
5 HP & Field Supplied Drive

1079
1094
1111
1129
1149
1171
1194
1219
1245
1273
1302
1333
1365
1398
-

2.34
2.48
2.64
2.82
3.02
3.23
3.46
3.72
3.99
4.28
4.59
4.91
5.26
5.62
-

1119
1135
1152
1170
1190
1211
1235
1259
1285
1313
1343
1373
1405
-

2.52
2.66
2.82
3.00
3.19
3.41
3.64
3.89
4.16
4.45
4.76
5.09
5.44
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

106

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH037-150 Bottom Duct Application
ZH037 (3.0 Ton) Bottom Duct
Air Flow
(CFM)
900
1000
1100
1200
1300
1400
1500

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
605
621
637
651
666
681
697

Standard 1.5 HP & Drive
0.23
671
0.33
738
0.25
688
0.34
754
0.27
703
0.36
769
0.30
717
0.39
784
0.33
732
0.43
799
0.37
747
0.47
814
0.42
763
0.51
830

0.42
0.44
0.46
0.49
0.52
0.56
0.61

804
820
835
850
865
880
896

0.52
0.53
0.56
0.58
0.62
0.66
0.71

869
885
900
915
930
945
961

Hi Static 1.5 HP & Drive
0.62
933
0.71
995
0.63
949
0.72 1011
0.65
964
0.74 1026
0.68
979
0.77 1041
0.71
994
0.81 1056
0.75 1009 0.85 1071
0.80 1025 0.90 1087

0.80
0.82
0.84
0.87
0.90
0.94
0.99

1054 0.89 1111 0.98
1071 0.91 1127 1.00
1086 0.93 1142 1.02
1100 0.96 1157 1.05
1115 0.99 1172 1.08
1130 1.03 1187 1.12
1146 1.08 1203 1.17
1.5 HP & Field Supplied Drive

1164
1180
1195
1210
1225
1240
1256

1.07
1.09
1.11
1.13
1.17
1.21
1.26

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH049 (4.0 Ton) Bottom Duct
Air Flow
(CFM)
1200
1300
1400
1500
1600
1700
1800
1900
2000

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
651
0.30
666
0.33
681
0.37
697
0.42
714
0.47
732
0.53
751
0.60
771
0.68
793
0.75

717
732
747
763
780
798
817
837
859

0.39
0.43
0.47
0.51
0.57
0.63
0.70
0.77
0.85

784
799
814
830
846
864
883
904
925

Standard 1.5 HP & Drive
0.49
850
0.58
915
0.52
865
0.62
930
0.56
880
0.66
945
0.61
896
0.71
961
0.66
913
0.76
978
0.73
930
0.82
996
0.79
950
0.89 1015
0.87
970
0.96 1035
0.95
991
1.04 1056

0.68
0.71
0.75
0.80
0.86
0.92
0.98
1.06
1.14

979
994
1009
1025
1042
1059
1079
1099
1120

0.77
0.81
0.85
0.90
0.95
1.01
1.08
1.15
1.23

1041
1056
1071
1087
1103
1121
1140
1161
1182

0.87
0.90
0.94
0.99
1.04
1.10
1.17
1.25
1.32

Hi Static 1.5 HP & Drive
1100 0.96 1157 1.05
1115 0.99 1172 1.08
1130 1.03 1187 1.12
1146 1.08 1203 1.17
1163 1.14 1220 1.22
1181 1.20 1237 1.29
1200 1.26 1257 1.35
1220 1.34 1277 1.43
1242 1.42 1298 1.51

1210
1225
1240
1256
1273
1291
1310
-

1.13
1.17
1.21
1.26
1.31
1.37
1.44
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZH061 (5.0 Ton) Bottom Duct
Air Flow
(CFM)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive
673
0.47
736
0.54
797
693
0.49
756
0.57
817
713
0.53
777
0.60
837
734
0.57
797
0.65
858
755
0.62
819
0.70
879
776
0.69
840
0.76
900
798
0.76
861
0.84
921
819
0.84
882
0.92
943
840
0.93
903
1.01
964
861
1.03
925
1.11
985
882
1.14
946
1.22 1006

0.63
0.65
0.69
0.73
0.79
0.85
0.92
1.00
1.10
1.20
1.30

855
874
895
916
937
958
979
1001
1022
1043
1064

Standard 1.5 HP & Drive
0.72
910
0.82
964
0.75
930
0.85
984
0.78
951
0.88 1004
0.83
971
0.92 1025
0.88
992
0.98 1046
0.94 1014 1.04 1067
1.02 1035 1.11 1089
1.10 1056 1.20 1110
1.19 1077 1.29 1131
1.29 1099 1.39 1152
1.40 1120 1.50 1173

0.92
0.95
0.98
1.03
1.08
1.14
1.22
1.30
1.39
1.49
1.60

1016
1036
1057
1077
1098
1120
1141
1162
1183
1204
1226

1.03
1.06
1.09
1.14
1.19
1.25
1.32
1.41
1.50
1.60
1.71

1067
1087
1107
1128
1149
1171
1192
1213
1234
1255
1276

Hi Static 2 HP & Drive
1.14 1117 1.25 1166
1.17 1137 1.28 1186
1.20 1157 1.31 1207
1.25 1178 1.36 1228
1.30 1199 1.41 1249
1.36 1221 1.47 1270
1.44 1242 1.55 1291
1.52 1263 1.63 1312
1.61 1284 1.72 1334
1.71 1305 1.82 1355
1.82 1326 1.93 1376
3 HP & Field Supplied Drive

1.36
1.39
1.42
1.47
1.52
1.59
1.66
1.74
1.83
1.93
2.04

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

107

528150-YTG-T-0514
ZH078 (6.5 Ton) Bottom Duct
Air Flow
(CFM)
1800
2000
2200
2400
2600
2800
3000
3200
3400

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
775
0.31
850
0.53
803
0.45
878
0.67
838
0.60
913
0.82
878
0.78
953
1.00
923
0.98
997
1.20
971
1.20 1046 1.42
1023 1.44 1097 1.66
1077 1.71 1151 1.93
1133 1.99 1208 2.21

924
952
986
1027
1071
1119
1171
1225
-

Standard 1.5 HP & Drive
0.72
998
0.89 1072
0.86 1026 1.03 1100
1.01 1060 1.19 1134
1.19 1100 1.36 1174
1.39 1145 1.56 1219
1.61 1193 1.78 1267
1.85 1245 2.03 1319
2.12 1299 2.29
-

1.05
1.19
1.34
1.52
1.72
1.94
2.18
-

1147
1175
1210
1250
1294
1343
-

Hi Static 2 HP & Drive
1.20 1224 1.35 1303 1.51
1.34 1252 1.49 1331 1.65
1.49 1286 1.65 1365 1.81
1.67 1327 1.82 1405 1.98
1.87 1371 2.02 1450 2.18
2.09 1419 2.24
2 HP & Field Supplied Drive

1384
1412
1447
1487
-

1.69
1.83
1.98
2.16
-

1469
1497
1532
-

1.89
2.03
2.18
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH090 (7.5 Ton) Bottom Duct
Air Flow
(CFM)
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
803
0.45
878
0.67
838
0.60
913
0.82
878
0.78
953
1.00
923
0.98
997
1.20
971
1.20 1046 1.42
1023 1.44 1097 1.66
1077 1.71 1151 1.93
1133 1.99 1208 2.21
1192 2.30 1267 2.52
1253 2.63 1327 2.85

952
986
1027
1071
1119
1171
1225
1282
1341
1401

Standard 1.5 HP & Drive
0.86 1026 1.03 1100
1.01 1060 1.19 1134
1.19 1100 1.36 1174
1.39 1145 1.56 1219
1.61 1193 1.78 1267
1.85 1245 2.03 1319
2.12 1299 2.29 1373
2.41 1356 2.58 1430
2.71 1414 2.88 1489
3.04 1475 3.21 1549

1.19
1.34
1.52
1.72
1.94
2.18
2.45
2.73
3.04
3.37

Hi Static 3 HP & Drive
1175 1.34 1252 1.49 1331
1210 1.49 1286 1.65 1365
1250 1.67 1327 1.82 1405
1294 1.87 1371 2.02 1450
1343 2.09 1419 2.24 1498
1394 2.33 1471 2.49 1550
1448 2.60 1525 2.75 1604
1505 2.88 1582 3.04 1661
1564 3.19 1641 3.34
3 HP & Field Supplied Drive

1.65
1.81
1.98
2.18
2.40
2.65
2.91
3.20
-

1412
1447
1487
1532
1580
1632
1686
1742
-

1.83
1.98
2.16
2.36
2.58
2.82
3.09
3.37
-

1497
1532
1572
1617
1665
1717
1771
-

2.03
2.18
2.36
2.56
2.78
3.02
3.29
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH102 (8.5 Ton) Bottom Duct
Air Flow
(CFM)
2600
2800
3000
3200
3400
3600
3800
4000
4200

1.
2.
3.
4.

108

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
674
0.71
689
0.86
707
1.01
728
1.17
751
1.34
776
1.53
804
1.74
835
1.97
867
2.21

731
746
764
785
808
833
861
892
924

Standard 2 HP & Drive
0.88
786
1.05
838
1.02
801
1.20
854
1.17
819
1.35
872
1.33
840
1.51
892
1.51
863
1.68
915
1.70
888
1.87
941
1.90
916
2.08
969
2.13
947
2.31
999
2.37
979
2.55 1032

1.24
1.38
1.53
1.69
1.87
2.06
2.26
2.49
2.73

887
903
921
941
964
990
1018
1048
1081

1.42
1.56
1.71
1.87
2.05
2.24
2.44
2.67
2.91

933
948
966
987
1010
1035
1063
1094
1127

1.59
1.73
1.88
2.04
2.22
2.41
2.61
2.84
3.08

Hi Static 3 HP & Drive
974
1.74 1010 1.87 1040 1.97
989
1.88 1025 2.01 1056 2.11
1007 2.03 1043 2.16 1074 2.26
1028 2.20 1064 2.33 1094 2.42
1051 2.37 1087 2.50 1117 2.60
1076 2.56 1112 2.69 1142 2.79
1104 2.77 1140 2.90 1170 2.99
1135 2.99
3 HP & Field Supplied Drive

1064
1080
1098
1118
1141
1167
-

2.03
2.17
2.32
2.48
2.66
2.85
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH120 (10 Ton) Bottom Duct
Air Flow
(CFM)

2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied
Drive
722
0.83
744
0.97
769
1.13
797
1.32
828
1.52
861
1.75
897
2.00
935
2.27
976
2.57
1019 2.88
1065 3.22

Standard 2 HP & Drive
776
798
823
851
882
915
951
989
1030
1073
1119

0.97
1.12
1.28
1.46
1.67
1.90
2.15
2.42
2.72
3.03
3.36

828
850
875
903
934
967
1002
1041
1082
1125
-

1.11
1.26
1.42
1.60
1.81
2.04
2.29
2.56
2.86
3.17
-

878
900
925
953
983
1017
1052
1091
1132
1175
-

1.25
1.39
1.55
1.74
1.94
2.17
2.42
2.69
2.99
3.30
-

926
949
974
1001
1032
1065
1101
1139
1180
1223
-

Hi Static 3 HP & Drive
1.37
973
1.50 1018
1.52
995
1.64 1041
1.68 1020 1.80 1066
1.86 1048 1.99 1093
2.07 1078 2.19 1124
2.30 1112 2.42 1157
2.55 1147 2.67 1193
2.82 1186 2.95 1231
3.12 1227 3.24 1272
3.43
3 HP & Field Supplied Drive

1.62
1.76
1.92
2.11
2.32
2.54
2.80
3.07
3.36
-

1063
1085
1110
1138
1168
1201
1237
1275
-

1.74
1.88
2.05
2.23
2.44
2.67
2.92
3.19
-

1106
1128
1153
1181
1212
1245
1280
1319
-

1.86
2.00
2.17
2.35
2.56
2.79
3.04
3.31
-

1149
1171
1196
1224
1254
1287
1323
1362
-

1.99
2.13
2.29
2.48
2.68
2.91
3.16
3.43
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZH150 (12.5 Ton) Bottom Duct
Air Flow
(CFM)
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
797
1.32
851
1.46
828
1.52
882
1.67
861
1.75
915
1.90
897
2.00
951
2.15
935
2.27
989
2.42
976
2.57 1030 2.72
1019 2.88 1073 3.03
1065 3.22 1119 3.36
1113 3.57 1167 3.72
1163 3.94 1217 4.09
1216 4.34 1270 4.48
1270 4.75 1324 4.89
1327 5.17 1381 5.32
1385 5.62
-

903
934
967
1002
1041
1082
1125
1171
1219
1269
1321
1376
1433
-

1.60
1.81
2.04
2.29
2.56
2.86
3.17
3.50
3.86
4.23
4.62
5.03
5.46
-

953
983
1017
1052
1091
1132
1175
1221
1269
1319
1371
1426
1483
-

Standard 3 HP & Drive
1.74 1001 1.86 1048 1.99
1.94 1032 2.07 1078 2.19
2.17 1065 2.30 1112 2.42
2.42 1101 2.55 1147 2.67
2.69 1139 2.82 1186 2.95
2.99 1180 3.12 1227 3.24
3.30 1223 3.43 1270 3.55
3.64 1269 3.76 1316 3.89
3.99 1317 4.12 1364 4.24
4.36 1367 4.49 1414 4.62
4.76 1420 4.88 1466 5.01
5.17 1474 5.29 1521 5.42
5.59 1531 5.72
5 HP & Field Supplied Drive

1093
1124
1157
1193
1231
1272
1315
1361
1409
1459
1512
1566
-

2.11
2.32
2.54
2.80
3.07
3.36
3.67
4.01
4.36
4.74
5.13
5.54
-

1138
1168
1201
1237
1275
1316
1360
1405
1453
1504
1556
1611
-

Hi Static 5 HP & Drive
2.23 1181 2.35 1224
2.44 1212 2.56 1254
2.67 1245 2.79 1287
2.92 1280 3.04 1323
3.19 1319 3.31 1362
3.48 1360 3.60 1402
3.80 1403 3.92 1446
4.13 1449 4.25 1491
4.48 1497 4.61 1540
4.86 1547 4.98 1590
5.25 1600 5.37 1642
5.66
-

2.48
2.68
2.91
3.16
3.43
3.73
4.04
4.38
4.73
5.10
5.50
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

109

528150-YTG-T-0514

ZJ037-150 Side Duct Application
ZJ037 (3.0 Ton) Side Duct
Air Flow
(CFM)
900
1000
1100
1200
1300
1400
1500

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
560
582
601
620
638
655
673

0.29
0.29
0.30
0.32
0.35
0.39
0.43

Standard 1.5 HP & Drive
628
0.35
695
0.42
650
0.34
716
0.42
670
0.35
736
0.43
688
0.37
754
0.45
706
0.40
772
0.48
724
0.44
790
0.51
741
0.48
807
0.56

760
781
801
819
837
855
872

0.51
0.51
0.52
0.54
0.57
0.60
0.65

823
845
864
883
901
918
936

0.61
0.61
0.62
0.64
0.67
0.70
0.75

Hi Static 1.5 HP & Drive
886
0.72
949
0.82
908
0.71
970
0.82
927
0.72
990
0.83
946
0.74 1008 0.85
964
0.77 1026 0.88
981
0.81 1044 0.91
999
0.85 1061 0.96

1011
1032
1052
1070
1088
1106
1124

0.92 1073 1.01 1136
0.92 1095 1.01 1158
0.93 1114 1.02 1177
0.95 1133 1.04 1196
0.98 1151 1.06 1214
1.01 1168 1.10 1231
1.06 1186 1.15 1249
1.5 HP & Field Supplied Drive

1.09
1.08
1.09
1.11
1.14
1.18
1.22

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZJ049 (4.0 Ton) Side Duct
Air Flow
(CFM)
1200
1300
1400
1500
1600
1700
1800
1900
2000

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
608
0.25
623
0.28
637
0.31
650
0.35
664
0.39
678
0.44
693
0.50
708
0.56
725
0.62

677
692
706
720
734
748
763
778
794

0.34
0.37
0.40
0.44
0.49
0.54
0.59
0.65
0.72

744
758
772
786
800
814
829
844
860

0.44
0.47
0.50
0.54
0.58
0.63
0.69
0.75
0.82

Standard 1.5 HP & Drive
807
0.54
868
0.64
822
0.57
883
0.67
836
0.60
897
0.70
849
0.64
911
0.74
863
0.68
924
0.78
877
0.73
938
0.83
892
0.79
953
0.89
907
0.85
968
0.95
924
0.92
985
1.02

927
942
956
970
984
998
1013
1028
1044

0.74
0.77
0.80
0.84
0.88
0.93
0.99
1.05
1.12

986
1001
1015
1028
1042
1056
1071
1086
1102

0.84
0.86
0.90
0.93
0.98
1.03
1.08
1.15
1.21

1043
1058
1072
1086
1100
1114
1129
1144
1160

Hi Static 1.5 HP & Drive
0.93 1101 1.02 1160
0.96 1116 1.04 1175
0.99 1130 1.08 1189
1.03 1144 1.12 1202
1.07 1158 1.16 1216
1.12 1172 1.21 1230
1.18 1186 1.26 1245
1.24 1202 1.33 1260
1.30 1218 1.39 1277

1.10
1.13
1.16
1.20
1.24
1.29
1.35
1.41
1.47

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive

ZJ061 (5.0 Ton) Side Duct
Air Flow
(CFM)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

1.
2.
3.
4.

110

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
659
675
691
707
724
741
759
778
797
817
838

1.5 HP & Field Suplied Drive
0.35
719
0.46
780
0.38
735
0.50
796
0.42
751
0.54
812
0.47
767
0.58
829
0.53
784
0.64
846
0.59
801
0.70
863
0.65
819
0.77
881
0.73
838
0.84
900
0.81
857
0.92
919
0.90
877
1.01
939
1.00
898
1.11
960

0.57
0.60
0.64
0.69
0.75
0.81
0.87
0.95
1.03
1.12
1.22

843
859
875
891
908
925
943
962
981
1002
1022

0.67
0.71
0.75
0.79
0.85
0.91
0.98
1.05
1.13
1.22
1.32

905
920
936
953
970
987
1005
1024
1043
1063
1084

Standard 1.5 HP & Drive
0.77
964
0.87 1020
0.81
980
0.91 1036
0.85
996
0.95 1052
0.90 1012 0.99 1069
0.95 1029 1.05 1085
1.01 1047 1.11 1103
1.08 1065 1.18 1121
1.15 1083 1.25 1139
1.23 1103 1.33 1159
1.32 1123 1.42 1179
1.42 1144 1.52 1200

0.97
1.01
1.05
1.09
1.15
1.21
1.28
1.35
1.43
1.52
1.62

1071
1087
1103
1120
1137
1154
1172
1191
1210
1230
1251

1.07
1.11
1.15
1.20
1.25
1.31
1.38
1.45
1.53
1.62
1.72

Hi Static 2 HP & Drive
1116 1.17 1154 1.28
1132 1.21 1170 1.32
1148 1.25 1186 1.36
1165 1.30 1202 1.41
1182 1.35 1219 1.46
1199 1.41 1236 1.52
1217 1.48 1254 1.59
1236 1.56 1273 1.66
1255 1.64 1292 1.74
1275 1.73 1312 1.83
1296 1.82 1333 1.93
FS4

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

Johnson Controls Unitary Products

528150-YTG-T-0514
ZJ078 (6.5 Ton) Side Duct
Air Flow
(CFM)
1800
2000
2200
2400
2600
2800
3000
3200
3400

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
514
529
544
559
574
590
607
624
641

FS4
0.15
586
0.23
601
0.33
616
0.43
631
0.54
646
0.67
662
0.80
679
0.95
695
1.10
713

0.33
0.41
0.51
0.61
0.72
0.85
0.98
1.13
1.28

657
672
687
702
717
733
750
766
784

0.52
0.60
0.69
0.80
0.91
1.03
1.17
1.31
1.47

727
741
756
771
787
802
819
836
853

Standard 1.5 HP & Drive
0.71
794
0.89
857
0.79
808
0.97
872
0.88
823
1.07
886
0.98
838
1.17
902
1.10
853
1.28
917
1.22
869
1.41
933
1.36
886
1.54
949
1.50
903
1.69
966
1.66
920
1.84
984

1.07
1.15
1.24
1.35
1.46
1.59
1.72
1.86
2.02

917
931
946
961
977
993
1009
1026
1043

1.23
1.31
1.41
1.51
1.62
1.75
1.88
2.03
2.18

972
986
1001
1016
1032
1047
1064
1081
1098

Hi Static 2 HP & Drive
1.38 1021 1.50 1064
1.46 1036 1.58 1079
1.55 1051 1.67 1094
1.65 1066 1.78 1109
1.77 1081 1.89 1124
1.89 1097 2.02 1140
2.03 1113 2.15 1157
2.17 1130 2.29
2.33
FS4

1.59
1.67
1.77
1.87
1.98
2.11
2.24
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZJ090 (7.5 Ton) Side Duct
Air Flow
(CFM)

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4

2000
2200
2400
2600
2800
3000
3200
3400
3600
3800

1.
2.
3.
4.

619
631
642
652
663
675
688
703
718

0.07
0.16
0.27
0.39
0.53
0.68
0.84
1.03
1.23

656
670
682
692
703
714
726
739
753
769

0.24
0.32
0.41
0.52
0.64
0.77
0.92
1.09
1.28
1.47

711
724
736
747
757
768
780
793
807
823

0.48
0.57
0.66
0.76
0.88
1.02
1.17
1.34
1.52
1.72

768
781
793
804
814
825
837
850
864
880

Standard 1.5 HP & Drive
0.73
826
0.96
886
0.81
840
1.04
899
0.90
852
1.14
911
1.01
862
1.24
922
1.13
873
1.36
932
1.26
884
1.50
943
1.41
896
1.65
955
1.58
909
1.82
968
1.76
923
2.00
983
1.96
939
2.20
998

1.19
1.27
1.36
1.47
1.59
1.73
1.88
2.04
2.23
2.43

945
959
970
981
992
1003
1014
1027
1042
1058

1.41
1.49
1.58
1.69
1.81
1.94
2.09
2.26
2.44
2.64

1003
1016
1028
1039
1049
1060
1072
1085
1100
1115

Hi Static 3 HP & Drive
1.61 1058 1.79 1110
1.69 1072 1.87 1124
1.78 1084 1.97 1136
1.89 1094 2.07 1146
2.01 1105 2.19 1157
2.14 1116 2.33 1168
2.29 1128 2.48 1180
2.46 1141 2.65 1193
2.64 1155 2.83
2.84 1171 3.03
-

1.95
2.04
2.13
2.24
2.36
2.49
2.64
2.81
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZJ102 (8.5 Ton) Side Duct
Air Flow
(CFM)
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
654
0.32
706
0.53
664
0.43
716
0.64
675
0.53
726
0.74
686
0.63
738
0.84
699
0.75
750
0.96
713
0.88
764
1.09
728
1.02
779
1.23
745
1.18
796
1.39
763
1.36
815
1.57
783
1.55
835
1.76
805
1.77
856
1.98

755
765
776
787
800
814
829
846
864
884
906

0.73
0.83
0.94
1.04
1.16
1.28
1.43
1.59
1.76
1.96
2.17

Standard 2 HP & Drive
803
0.92
849
1.10
813
1.02
859
1.20
824
1.12
870
1.30
835
1.23
881
1.41
847
1.34
893
1.52
861
1.47
907
1.65
877
1.61
923
1.79
893
1.77
939
1.95
912
1.95
958
2.13
932
2.15
978
2.33
953
2.36
999
2.54

893
904
914
925
938
952
967
984
1002
1022
1044

1.27
1.38
1.48
1.58
1.70
1.83
1.97
2.13
2.31
2.50
2.72

937
947
957
969
981
995
1010
1027
1046
1066
1087

1.44
1.55
1.65
1.76
1.87
2.00
2.14
2.30
2.48
2.67
2.89

Hi Static 3 HP & Drive
979
1.62 1020 1.79 1061 1.96
989
1.72 1030 1.89 1071 2.07
1000 1.82 1041 1.99 1082 2.17
1011 1.93 1052 2.10 1093 2.27
1024 2.04 1065 2.21 1106 2.39
1037 2.17 1079 2.34 1119 2.52
1053 2.31 1094 2.48 1135 2.66
1069 2.47 1111 2.64 1152 2.82
1088 2.65 1129 2.82 1170 3.00
1108 2.84 1149 3.02 1190 3.19
1129 3.06 1171 3.23 1211 3.41
3 HP & Field Supplied Drive

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

111

528150-YTG-T-0514

ZJ120 (10 Ton) Side Duct
Air Flow
(CFM)
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
675
0.53
726
0.74
686
0.63
738
0.84
699
0.75
750
0.96
713
0.88
764
1.09
728
1.02
779
1.23
745
1.18
796
1.39
763
1.36
815
1.57
783
1.55
835
1.76
805
1.77
856
1.98
828
2.00
879
2.21
852
2.25
904
2.46
879
2.52
930
2.73
906
2.81
958
3.02

776
787
800
814
829
846
864
884
906
929
953
980
1007

0.94
1.04
1.16
1.28
1.43
1.59
1.76
1.96
2.17
2.41
2.66
2.93
3.22

824
835
847
861
877
893
912
932
953
976
1001
1027
1055

Standard 2 HP & Drive
1.12
870
1.30
914
1.23
881
1.41
925
1.34
893
1.52
938
1.47
907
1.65
952
1.61
923
1.79
967
1.77
939
1.95
984
1.95
958
2.13 1002
2.15
978
2.33 1022
2.36
999
2.54 1044
2.59 1022 2.77 1067
2.85 1047 3.03 1092
3.12 1073 3.30
3.41
-

1.48
1.58
1.70
1.83
1.97
2.13
2.31
2.50
2.72
2.95
3.20
-

957
969
981
995
1010
1027
1046
1066
1087
1110
1135
-

Hi Static 3 HP & Drive
1.65 1000 1.82 1041 1.99 1082
1.76 1011 1.93 1052 2.10 1093
1.87 1024 2.04 1065 2.21 1106
2.00 1037 2.17 1079 2.34 1119
2.14 1053 2.31 1094 2.48 1135
2.30 1069 2.47 1111 2.64 1152
2.48 1088 2.65 1129 2.82 1170
2.67 1108 2.84 1149 3.02 1190
2.89 1129 3.06 1171 3.23 1211
3.12 1152 3.29
3.37
3 HP & Field Supplied Drive

2.17
2.27
2.39
2.52
2.66
2.82
3.00
3.19
3.41
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZJ150 (12.5 Ton) Side Duct
Air Flow
(CFM)
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
713
728
745
763
783
805
828
852
879
906
936
966
999
1032
1067
1103

0.88
1.02
1.18
1.36
1.55
1.77
2.00
2.25
2.52
2.81
3.12
3.45
3.80
4.16
4.54
4.94

Field Supplied Drive
764
1.09
814
1.28
779
1.23
829
1.43
796
1.39
846
1.59
815
1.57
864
1.76
835
1.76
884
1.96
856
1.98
906
2.17
879
2.21
929
2.41
904
2.46
953
2.66
930
2.73
980
2.93
958
3.02 1007 3.22
987
3.33 1037 3.53
1018 3.66 1067 3.86
1050 4.01 1100 4.20
1084 4.37 1133 4.57
1119 4.75 1168 4.95
1155 5.15 1204 5.34
Hi Static 5 HP & Drive

861
877
893
912
932
953
976
1001
1027
1055
1084
1115
1147
1181
1216
1252

1.47
1.61
1.77
1.95
2.15
2.36
2.59
2.85
3.12
3.41
3.72
4.05
4.39
4.75
5.13
5.53

907
923
939
958
978
999
1022
1047
1073
1101
1130
1161
1193
1227
1262
1298

1.65
1.79
1.95
2.13
2.33
2.54
2.77
3.03
3.30
3.59
3.90
4.23
4.57
4.93
5.31
5.71

952
967
984
1002
1022
1044
1067
1092
1118
1146
1175
1206
1238
1271
1306
-

1.83
1.97
2.13
2.31
2.50
2.72
2.95
3.20
3.47
3.76
4.07
4.40
4.75
5.11
5.49
-

Standard 3 HP & Drive
995
2.00 1037 2.17
1010 2.14 1053 2.31
1027 2.30 1069 2.47
1046 2.48 1088 2.65
1066 2.67 1108 2.84
1087 2.89 1129 3.06
1110 3.12 1152 3.29
1135 3.37 1177 3.54
1161 3.65 1203 3.82
1189 3.94 1231 4.11
1218 4.24 1260 4.42
1249 4.57 1291 4.74
1281 4.92 1323 5.09
1315 5.28 1357 5.45
1350 5.66
5 HP & Field Supplied Drive

1079
1094
1111
1129
1149
1171
1194
1219
1245
1273
1302
1333
1365
1398
-

2.34
2.48
2.64
2.82
3.02
3.23
3.46
3.72
3.99
4.28
4.59
4.91
5.26
5.62
-

1119
1135
1152
1170
1190
1211
1235
1259
1285
1313
1343
1373
1405
-

2.52
2.66
2.82
3.00
3.19
3.41
3.64
3.89
4.16
4.45
4.76
5.09
5.44
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

112

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ037-150 Bottom Duct Application
ZJ037 (3.0 Ton) Bottom Duct
Air Flow
(CFM)
900
1000
1100
1200
1300
1400
1500

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
605
621
637
651
666
681
697

Standard 1.5 HP & Drive
0.23
671
0.33
738
0.25
688
0.34
754
0.27
703
0.36
769
0.30
717
0.39
784
0.33
732
0.43
799
0.37
747
0.47
814
0.42
763
0.51
830

0.42
0.44
0.46
0.49
0.52
0.56
0.61

804
820
835
850
865
880
896

0.52
0.53
0.56
0.58
0.62
0.66
0.71

869
885
900
915
930
945
961

Hi Static 1.5 HP & Drive
0.62
933
0.71
995
0.63
949
0.72 1011
0.65
964
0.74 1026
0.68
979
0.77 1041
0.71
994
0.81 1056
0.75 1009 0.85 1071
0.80 1025 0.90 1087

0.80
0.82
0.84
0.87
0.90
0.94
0.99

1054 0.89 1111 0.98
1071 0.91 1127 1.00
1086 0.93 1142 1.02
1100 0.96 1157 1.05
1115 0.99 1172 1.08
1130 1.03 1187 1.12
1146 1.08 1203 1.17
1.5 HP & Field Supplied Drive

1164
1180
1195
1210
1225
1240
1256

1.07
1.09
1.11
1.13
1.17
1.21
1.26

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZJ049 (4.0 Ton) Bottom Duct
Air Flow
(CFM)
1200
1300
1400
1500
1600
1700
1800
1900
2000

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
635
0.25
648
0.28
661
0.32
675
0.37
690
0.42
706
0.48
723
0.55
741
0.62
760
0.69

704
717
730
744
759
775
792
810
829

0.34
0.38
0.42
0.46
0.51
0.57
0.64
0.71
0.79

770
782
796
810
825
841
857
875
894

Standard 1.5 HP & Drive
0.44
832
0.54
893
0.47
845
0.58
906
0.51
858
0.62
919
0.56
872
0.66
933
0.61
887
0.72
948
0.67
903
0.77
964
0.74
920
0.84
981
0.81
938
0.91
999
0.88
957
0.99 1018

0.65
0.68
0.72
0.77
0.82
0.88
0.94
1.01
1.09

953
966
979
993
1008
1024
1041
1059
1078

0.75
0.78
0.82
0.87
0.92
0.98
1.04
1.11
1.19

1013
1025
1039
1053
1068
1084
1101
1118
1137

0.85
0.88
0.92
0.96
1.02
1.08
1.14
1.21
1.29

Hi Static 1.5 HP & Drive
1073 0.94 1134 1.02
1085 0.97 1147 1.05
1099 1.01 1160 1.09
1113 1.05 1174 1.14
1128 1.11 1189 1.19
1144 1.17 1205 1.25
1161 1.23 1222 1.31
1178 1.30 1240 1.38
1197 1.38 1258 1.46

1197
1210
1223
1237
1252
1268
1285
1303
1322

1.08
1.12
1.16
1.20
1.26
1.31
1.38
1.45
1.53

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZJ061 (5.0 Ton) Bottom Duct
Air Flow
(CFM)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive
673
0.47
736
0.54
797
693
0.49
756
0.57
817
713
0.53
777
0.60
837
734
0.57
797
0.65
858
755
0.62
819
0.70
879
776
0.69
840
0.76
900
798
0.76
861
0.84
921
819
0.84
882
0.92
943
840
0.93
903
1.01
964
861
1.03
925
1.11
985
882
1.14
946
1.22 1006

0.63
0.65
0.69
0.73
0.79
0.85
0.92
1.00
1.10
1.20
1.30

855
874
895
916
937
958
979
1001
1022
1043
1064

0.72
0.75
0.78
0.83
0.88
0.94
1.02
1.10
1.19
1.29
1.40

Standard 1.5 HP & Drive
910
0.82
964
0.92
930
0.85
984
0.95
951
0.88 1004 0.98
971
0.92 1025 1.03
992
0.98 1046 1.08
1014 1.04 1067 1.14
1035 1.11 1089 1.22
1056 1.20 1110 1.30
1077 1.29 1131 1.39
1099 1.39 1152 1.49
1120 1.50 1173 1.60

1016
1036
1057
1077
1098
1120
1141
1162
1183
1204
1226

1.03
1.06
1.09
1.14
1.19
1.25
1.32
1.41
1.50
1.60
1.71

1067
1087
1107
1128
1149
1171
1192
1213
1234
1255
1276

1.14
1.17
1.20
1.25
1.30
1.36
1.44
1.52
1.61
1.71
1.82

Hi Static 2 HP & Drive
1117 1.25 1166 1.36
1137 1.28 1186 1.39
1157 1.31 1207 1.42
1178 1.36 1228 1.47
1199 1.41 1249 1.52
1221 1.47 1270 1.59
1242 1.55 1291 1.66
1263 1.63 1312 1.74
1284 1.72 1334 1.83
1305 1.82 1355 1.93
1326 1.93 1376 2.04
2 HP & Field Supplied Drive

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

113

528150-YTG-T-0514

ZJ078 (6.5 Ton) Bottom Duct
Air Flow
(CFM)
1800
2000
2200
2400
2600
2800
3000
3200
3400

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
603
0.13
627
0.26
650
0.40
673
0.55
696
0.71
720
0.87
745
1.05
771
1.24
797
1.44

656
680
703
726
749
773
798
824
850

0.36
0.49
0.63
0.78
0.94
1.10
1.28
1.47
1.67

Standard 1.5 HP & Drive
718
0.58
784
0.79
742
0.71
808
0.92
765
0.85
831
1.06
788
1.00
854
1.21
811
1.16
878
1.37
835
1.32
902
1.53
860
1.50
926
1.71
886
1.69
952
1.90
912
1.89
979
2.10

851
875
898
921
944
968
993
1019
1045

0.98
1.12
1.25
1.40
1.56
1.73
1.91
2.09
2.29

914
937
961
984
1007
1031
1056
1081
1108

1.16
1.29
1.43
1.58
1.73
1.90
2.08
2.27
2.47

968
992
1015
1038
1061
1085
1110
1136
1162

Hi Static 2 HP & Drive
1.31 1010 1.43 1035 1.53
1.44 1034 1.57 1059 1.66
1.58 1057 1.71 1082 1.80
1.73 1080 1.85 1105 1.95
1.89 1103 2.01 1128 2.10
2.05 1127 2.18 1152 2.27
2.23 1152 2.36 1177 2.45
2.42 1178 2.54 1203 2.64
2.62 1204 2.74 1229 2.84
3 HP & Field Supplied Drive

1039
1063
1086
1109
1133
1157
1181
1207
1234

1.59
1.72
1.86
2.01
2.16
2.33
2.51
2.70
2.90

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZJ090 (7.5 Ton) Bottom Duct
Air Flow
(CFM)
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800

1.
2.
3.
4.

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
644
0.11
666
0.26
689
0.42
712
0.60
736
0.80
761
1.00
787
1.22
813
1.46
841
1.70
869
1.96

698
720
743
766
790
815
840
867
894
923

0.38
0.53
0.69
0.87
1.06
1.27
1.49
1.73
1.97
2.22

755
777
800
823
847
872
898
924
952
980

Standard 1.5 HP & Drive
0.62
814
0.85
874
0.77
836
1.00
896
0.93
859
1.16
919
1.11
882
1.34
942
1.31
906
1.53
967
1.52
931
1.74
991
1.74
957
1.96 1017
1.97
984
2.19 1044
2.21 1011 2.44 1071
2.47 1039 2.69 1099

1.06
1.21
1.37
1.55
1.74
1.95
2.17
2.40
2.65
2.90

933
956
978
1002
1026
1051
1076
1103
1130
1158

1.26
1.41
1.57
1.75
1.94
2.15
2.37
2.61
2.85
3.10

990
1012
1035
1058
1082
1107
1133
1160
1187
1215

1.46
1.61
1.77
1.95
2.14
2.35
2.57
2.80
3.05
3.30

Hi Static 3 HP & Drive
1043 1.66 1090 1.87 1131
1065 1.81 1113 2.02 1153
1088 1.97 1135 2.18 1176
1111 2.15 1159 2.36 1199
1135 2.34 1183 2.55 1223
1160 2.55 1208 2.76 1248
1186 2.77 1233 2.98 1274
1212 3.01 1260 3.21
3 HP & Field Supplied Drive

2.09
2.24
2.40
2.58
2.78
2.98
3.20
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZJ102 (8.5 Ton) Bottom Duct
Air Flow
(CFM)
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200

1.
2.
3.
4.

114

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4
685
0.59
702
0.70
722
0.83
744
0.97
769
1.13
797
1.32
828
1.52
861
1.75
897
2.00
935
2.27
976
2.57

739
756
776
798
823
851
882
915
951
989
1030

0.74
0.85
0.97
1.12
1.28
1.46
1.67
1.90
2.15
2.42
2.72

Standard 2 HP & Drive
791
0.88
841
1.01
808
0.99
858
1.12
828
1.11
878
1.25
850
1.26
900
1.39
875
1.42
925
1.55
903
1.60
953
1.74
934
1.81
983
1.94
967
2.04 1017 2.17
1002 2.29 1052 2.42
1041 2.56 1091 2.69
1082 2.86 1132 2.99

889
906
926
949
974
1001
1032
1065
1101
1139
1180

1.14
1.25
1.37
1.52
1.68
1.86
2.07
2.30
2.55
2.82
3.12

936
953
973
995
1020
1048
1078
1112
1147
1186
1227

Hi Static 3 HP & Drive
1.27
981
1.39 1025 1.51 1069
1.37
999
1.49 1043 1.62 1086
1.50 1018 1.62 1063 1.74 1106
1.64 1041 1.76 1085 1.88 1128
1.80 1066 1.92 1110 2.05 1153
1.99 1093 2.11 1138 2.23 1181
2.19 1124 2.32 1168 2.44 1212
2.42 1157 2.54 1201 2.67 1245
2.67 1193 2.80 1237 2.92 1280
2.95 1231 3.07 1275 3.19 1319
3.24 1272 3.36
3 HP & Field Supplied Drive

1.63
1.74
1.86
2.00
2.17
2.35
2.56
2.79
3.04
3.31
-

1111
1129
1149
1171
1196
1224
1254
1287
1323
1362
-

1.75
1.86
1.99
2.13
2.29
2.48
2.68
2.91
3.16
3.43
-

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ120 (10 Ton) Bottom Duct
Air Flow
(CFM)

2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied
Drive
722
0.83
744
0.97
769
1.13
797
1.32
828
1.52
861
1.75
897
2.00
935
2.27
976
2.57
1019 2.88
1065 3.22

Standard 2 HP & Drive
776
798
823
851
882
915
951
989
1030
1073
1119

0.97
1.12
1.28
1.46
1.67
1.90
2.15
2.42
2.72
3.03
3.36

828
850
875
903
934
967
1002
1041
1082
1125
-

1.11
1.26
1.42
1.60
1.81
2.04
2.29
2.56
2.86
3.17
-

878
900
925
953
983
1017
1052
1091
1132
1175
-

1.25
1.39
1.55
1.74
1.94
2.17
2.42
2.69
2.99
3.30
-

926
949
974
1001
1032
1065
1101
1139
1180
1223
-

Hi Static 3 HP & Drive
1.37
973
1.50 1018
1.52
995
1.64 1041
1.68 1020 1.80 1066
1.86 1048 1.99 1093
2.07 1078 2.19 1124
2.30 1112 2.42 1157
2.55 1147 2.67 1193
2.82 1186 2.95 1231
3.12 1227 3.24 1272
3.43
3 HP & Field Supplied Drive

1.62
1.76
1.92
2.11
2.32
2.54
2.80
3.07
3.36
-

1063
1085
1110
1138
1168
1201
1237
1275
-

1.74
1.88
2.05
2.23
2.44
2.67
2.92
3.19
-

1106
1128
1153
1181
1212
1245
1280
1319
-

1.86
2.00
2.17
2.35
2.56
2.79
3.04
3.31
-

1149
1171
1196
1224
1254
1287
1323
1362
-

1.99
2.13
2.29
2.48
2.68
2.91
3.16
3.43
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZJ150 (12.5 Ton) Bottom Duct
Air Flow
(CFM)
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Field Supplied Drive
797
1.32
851
1.46
828
1.52
882
1.67
861
1.75
915
1.90
897
2.00
951
2.15
935
2.27
989
2.42
976
2.57 1030 2.72
1019 2.88 1073 3.03
1065 3.22 1119 3.36
1113 3.57 1167 3.72
1163 3.94 1217 4.09
1216 4.34 1270 4.48
1270 4.75 1324 4.89
1327 5.17 1381 5.32
1385 5.62
-

903
934
967
1002
1041
1082
1125
1171
1219
1269
1321
1376
1433
-

1.60
1.81
2.04
2.29
2.56
2.86
3.17
3.50
3.86
4.23
4.62
5.03
5.46
-

953
983
1017
1052
1091
1132
1175
1221
1269
1319
1371
1426
1483
-

Standard 3 HP & Drive
1.74 1001 1.86 1048 1.99
1.94 1032 2.07 1078 2.19
2.17 1065 2.30 1112 2.42
2.42 1101 2.55 1147 2.67
2.69 1139 2.82 1186 2.95
2.99 1180 3.12 1227 3.24
3.30 1223 3.43 1270 3.55
3.64 1269 3.76 1316 3.89
3.99 1317 4.12 1364 4.24
4.36 1367 4.49 1414 4.62
4.76 1420 4.88 1466 5.01
5.17 1474 5.29 1521 5.42
5.59 1531 5.72
5 HP & Field Supplied Drive

1093
1124
1157
1193
1231
1272
1315
1361
1409
1459
1512
1566
-

2.11
2.32
2.54
2.80
3.07
3.36
3.67
4.01
4.36
4.74
5.13
5.54
-

1138
1168
1201
1237
1275
1316
1360
1405
1453
1504
1556
1611
-

Hi Static 5 HP & Drive
2.23 1181 2.35 1224
2.44 1212 2.56 1254
2.67 1245 2.79 1287
2.92 1280 3.04 1323
3.19 1319 3.31 1362
3.48 1360 3.60 1402
3.80 1403 3.92 1446
4.13 1449 4.25 1491
4.48 1497 4.61 1540
4.86 1547 4.98 1590
5.25 1600 5.37 1642
5.66
-

2.48
2.68
2.91
3.16
3.43
3.73
4.04
4.38
4.73
5.10
5.50
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

115

528150-YTG-T-0514

ZR037-150 Side Duct Application
ZR037 (3.0 Ton) Side Duct
1

Available External Static Pressure - IWG
Air
Flow
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
(CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4

Standard 1.5 HP & Drive

Hi Static 1.5 HP & Drive

900

480

0.4

582

0.4

673

0.5

756

0.5

830

0.6

898

0.7

960

0.8

1018

0.9

1072

1.0

1124

1.1

1000

489

0.4

591

0.4

682

0.5

764

0.6

839

0.6

907

0.7

969

0.8

1026

0.9

1080

1.0

1132

1.1

1100

500

0.4

602

0.4

693

0.5

776

0.6

850

0.6

918

0.7

980

0.8

1038

0.9

1092

1.0

1144

1.1

1200

513

0.4

614

0.5

706

0.5

788

0.6

863

0.7

931

0.8

993

0.8

1050

0.9

1104

1.0

1156

1.1

1300

525

0.4

627

0.5

719

0.6

801

0.6

876

0.7

943

0.8

1005

0.9

1063

1.0

1117

1.1

1169

1.2

1400

537

0.5

639

0.5

731

0.6

813

0.7

888

0.7

955

0.8

1017

0.9

1075

1.0

1129

1.1

1181

1.2

1500

549

0.5

650

0.6

742

0.6

824

0.7

899

0.8

966

0.9

1028

0.9

1086

1.0

1140

1.1

1192

1.2

1.
2.
3.
4.

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZR049 (4.0 Ton) Side Duct
1

Available External Static Pressure - IWG
Air
Flow
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
(CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field
Supplied Drive

Standard 1.5 HP & Drive

Hi Static 1.5 HP & Drive

1200

513

0.4

614

0.5

706

0.5

788

0.6

863

0.7

931

0.8

993

0.8

1050

0.9

1104

1.0

1156

1.1

1300

525

0.4

627

0.5

719

0.6

801

0.6

876

0.7

943

0.8

1005

0.9

1063

1.0

1117

1.1

1169

1.2

1400

537

0.5

639

0.5

731

0.6

813

0.7

888

0.7

955

0.8

1017

0.9

1075

1.0

1129

1.1

1181

1.2

1500

549

0.5

650

0.6

742

0.6

824

0.7

899

0.8

966

0.9

1028

0.9

1086

1.0

1140

1.1

1192

1.2

1600

558

0.6

660

0.6

752

0.7

834

0.8

909

0.8

976

0.9

1038

1.0

1096

1.1

1150

1.2

1202

1.3

1700

566

0.6

668

0.7

760

0.7

842

0.8

917

0.9

984

1.0

1046

1.1

1104

1.1

1158

1.2

1210

1.4

1800

573

0.7

675

0.7

766

0.8

849

0.9

923

1.0

991

1.0

1053

1.1

1110

1.2

1164

1.3

1216

1.4

1900

577

0.8

679

0.8

771

0.9

853

1.0

928

1.0

995

1.1

1057

1.2

1115

1.3

1169

1.4

1221

1.5

2000

580

0.8

682

0.9

773

1.0

856

1.0

930

1.1

998

1.2

1060

1.3

1117

1.4

1172

1.5

1224

1.6

FS4

1.
2.
3.
4.

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZR061 (5.0 Ton) Side Duct
Air
Flow
(CFM)

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Standard 1.5 HP & Drive

Hi Static 2 HP & Drive

1500

616

0.5

685

0.6

766

0.7

833

0.8

905

0.9

975

1.0

1035

1.0

1101

1.1

1163

1.2

1229

1600

638

0.6

707

0.7

781

0.7

848

0.8

920

0.9

990

1.0

1050

1.1

1104

1.1

1166

1.2

1232

1.3
1.3

1700

655

0.6

724

0.7

796

0.8

863

0.9

935

1.0

1005

1.1

1064

1.1

1109

1.2

1172

1.3

1238

1.4

1800

670

0.7

739

0.8

810

0.8

877

0.9

949

1.0

1018

1.1

1078

1.2

1117

1.2

1179

1.3

1245

1.5

1900

686

0.7

755

0.8

823

0.9

890

1.0

962

1.1

1032

1.2

1091

1.2

1125

1.3

1187

1.4

1253

1.5

2000

702

0.8

772

0.9

836

1.0

903

1.1

975

1.2

1045

1.3

1078

1.3

1135

1.4

1197

1.5

1263

1.6

2100

722

0.9

791

1.0

849

1.0

916

1.1

988

1.2

1058

1.3

1089

1.4

1147

1.5

1209

1.6

1275

1.7

2200

745

0.9

814

1.0

861

1.1

928

1.2

1000

1.3

1050

1.4

1102

1.5

1159

1.6

1221

1.7

1287

1.8

2300

772

1.0

841

1.1

874

1.2

941

1.3

1013

1.4

1064

1.5

1115

1.6

1173

1.7

1235

1.8

-

-

2400

804

1.1

832

1.2

886

1.3

953

1.4

1033

1.4

1078

1.6

1130

1.7

1188

1.8

-

-

-

-

2500

841

1.2

844

1.3

898

1.4

965

1.5

1049

1.5

1094

1.7

-

-

-

-

2 HP & Field Supplied Drive

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

116

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR078-150 Side Duct Application
ZR078 (6.5 Ton) Side Duct
Air Flow
(CFM)
1800
2000
2200
2400
2600
2800
3000
3200
3400

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
778
803
833
866
902
941
983
1028
1074

1.5 HP & Field Supplied Drive
0.37
838
0.56
895
0.50
864
0.69
921
0.64
893
0.83
951
0.80
926
0.99
984
0.97
962
1.16 1020
1.16 1002 1.35 1059
1.37 1043 1.56 1101
1.60 1088 1.79 1145
1.84 1134 2.03 1192

0.73
0.85
1.00
1.15
1.33
1.52
1.73
1.95
2.20

951
977
1006
1039
1076
1115
1157
1201
-

0.88
1.00
1.14
1.30
1.47
1.67
1.88
2.10
-

Standard 1.5 HP & Drive
1005 1.01 1059 1.13
1031 1.14 1085 1.26
1061 1.28 1114 1.40
1094 1.43 1147 1.56
1130 1.61 1183 1.73
1169 1.80 1222 1.92
1211 2.01 1264 2.13
1255 2.24
-

1112
1138
1168
1201
1237
1276
1318
-

Hi Static 2 HP & Drive
1.25 1166 1.36 1221 1.47 1278
1.37 1192 1.49 1247 1.60 1304
1.51 1221 1.63 1276 1.74 1333
1.67 1254 1.78 1309 1.90 1366
1.85 1291 1.96 1346 2.07 1402
2.04 1330 2.15 1385 2.26
2.25
2 HP & Field Supplied Drive

1.59
1.72
1.86
2.02
2.19
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZR090 (7.5 Ton) Side Duct
Air Flow
(CFM)
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive
803
0.50
864
0.69
833
0.64
893
0.83
866
0.80
926
0.99
902
0.97
962
1.16
941
1.16 1002 1.35
983
1.37 1043 1.56
1028 1.60 1088 1.79
1074 1.84 1134 2.03
1123 2.10 1183 2.29
1174 2.38 1234 2.57

921
951
984
1020
1059
1101
1145
1192
1241
1292

0.85
1.00
1.15
1.33
1.52
1.73
1.95
2.20
2.46
2.74

Standard 1.5 HP & Drive
977
1.00 1031 1.14
1006 1.14 1061 1.28
1039 1.30 1094 1.43
1076 1.47 1130 1.61
1115 1.67 1169 1.80
1157 1.88 1211 2.01
1201 2.10 1255 2.24
1248 2.35 1302 2.48
1297 2.61 1351 2.74
1348 2.88 1402 3.02

1085
1114
1147
1183
1222
1264
1309
1355
1404
1455

1.26
1.40
1.56
1.73
1.92
2.13
2.36
2.60
2.86
3.14

Hi Static 3 HP & Drive
1138 1.37 1192 1.49 1247 1.60
1168 1.51 1221 1.63 1276 1.74
1201 1.67 1254 1.78 1309 1.90
1237 1.85 1291 1.96 1346 2.07
1276 2.04 1330 2.15 1385 2.26
1318 2.25 1372 2.36 1427 2.47
1362 2.47 1416 2.59 1471 2.70
1409 2.72 1463 2.83 1518 2.94
1458 2.98 1512 3.09 1567 3.21
1509 3.26 1562 3.37
3 HP & Field Supplied Drive

1304
1333
1366
1402
1442
1483
1528
1574
1623
-

1.72
1.86
2.02
2.19
2.38
2.59
2.82
3.06
3.32
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZR102 (8.5 Ton) Side Duct
Air Flow
(CFM)

2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2 HP & Field
Supplied Drive
684
0.48
695
0.58
706
0.67
719
0.78
732
0.89
747
1.02
764
1.16
783
1.33
803
1.51
825
1.71
849
1.92

Standard 2 HP & Drive
735
745
756
769
782
797
814
833
853
875
899

0.67
0.76
0.86
0.96
1.08
1.21
1.35
1.51
1.69
1.89
2.11

783
793
805
817
831
846
862
881
901
923
947

0.84
0.94
1.04
1.14
1.25
1.38
1.53
1.69
1.87
2.07
2.29

829
840
851
863
877
892
909
927
948
970
993

1.01
1.11
1.20
1.31
1.42
1.55
1.69
1.86
2.04
2.23
2.45

874
885
896
908
922
937
954
972
992
1014
1038

Hi Static 3 HP & Drive
1.17
1.27
1.36
1.47
1.58
1.71
1.85
2.02
2.20
2.39
2.61

918
928
939
952
965
980
997
1016
1036
1058
1082

1.32
1.42
1.52
1.62
1.74
1.86
2.01
2.17
2.35
2.55
2.77

960
970
981
994
1007
1023
1039
1058
1078
1100
1124

1.48
1.57
1.67
1.78
1.89
2.02
2.16
2.32
2.50
2.70
2.92

1001 1.63 1041 1.78
1011 1.73 1052 1.88
1023 1.82 1063 1.98
1035 1.93 1075 2.08
1049 2.04 1089 2.19
1064 2.17 1104 2.32
1080 2.31 1121 2.47
1099 2.48 1139 2.63
1119 2.66 1159 2.81
1141 2.86 1181 3.01
1165 3.07 1205 3.23
3 HP & Field Supplied Drive

1081
1091
1103
1115
1128
1144
1160
1179
1199
1221
1245

1.94
2.04
2.13
2.24
2.35
2.48
2.62
2.79
2.97
3.16
3.38

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

117

528150-YTG-T-0514

ZR120 (10 Ton) Side Duct
Air Flow
(CFM)
2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2 HP & Field Supplied Drive
706
0.67
756
0.86
719
0.78
769
0.96
732
0.89
782
1.08
747
1.02
797
1.21
764
1.16
814
1.35
783
1.33
833
1.51
803
1.51
853
1.69
825
1.71
875
1.89
849
1.92
899
2.11
874
2.16
924
2.35
901
2.42
952
2.61
930
2.70
981
2.88
961
2.99 1011 3.18

805
817
831
846
862
881
901
923
947
972
1000
1029
1059

1.04
1.14
1.25
1.38
1.53
1.69
1.87
2.07
2.29
2.52
2.78
3.06
3.35

Standard 2 HP & Drive
851
1.20
896
1.36
863
1.31
908
1.47
877
1.42
922
1.58
892
1.55
937
1.71
909
1.69
954
1.85
927
1.86
972
2.02
948
2.04
992
2.20
970
2.23 1014 2.39
993
2.45 1038 2.61
1019 2.69 1064 2.85
1046 2.95 1091 3.11
1075 3.23 1120 3.39
-

939
952
965
980
997
1016
1036
1058
1082
1107
1134
-

1.52
1.62
1.74
1.86
2.01
2.17
2.35
2.55
2.77
3.01
3.26
-

Hi Static 3 HP & Drive
981
1.67 1023 1.82 1063 1.98
994
1.78 1035 1.93 1075 2.08
1007 1.89 1049 2.04 1089 2.19
1023 2.02 1064 2.17 1104 2.32
1039 2.16 1080 2.31 1121 2.47
1058 2.32 1099 2.48 1139 2.63
1078 2.50 1119 2.66 1159 2.81
1100 2.70 1141 2.86 1181 3.01
1124 2.92 1165 3.07 1205 3.23
1149 3.16 1190 3.31
1177 3.42
3 HP & Field Supplied Drive

1103
1115
1128
1144
1160
1179
1199
1221
1245
-

2.13
2.24
2.35
2.48
2.62
2.79
2.97
3.16
3.38
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZR150 (12.5 Ton) Side Duct
Air Flow
(CFM)
3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3 HP & Field Supplied Drive
747
1.02
797
1.21
846
764
1.16
814
1.35
862
783
1.33
833
1.51
881
803
1.51
853
1.69
901
825
1.71
875
1.89
923
849
1.92
899
2.11
947
874
2.16
924
2.35
972
901
2.42
952
2.61 1000
930
2.70
981
2.88 1029
961
2.99 1011 3.18 1059
993
3.31 1043 3.49 1092
1027 3.64 1077 3.83 1126
1063 3.99 1113 4.18 1161
1100 4.36 1150 4.55 1198
1138 4.75 1188 4.93 1237
1178 5.15 1228 5.34 1277
Hi Static 5 HP & Drive

1.38
1.53
1.69
1.87
2.07
2.29
2.52
2.78
3.06
3.35
3.67
4.00
4.35
4.72
5.11
5.51

892
909
927
948
970
993
1019
1046
1075
1106
1138
1172
1207
1244
1283
1323

1.55
1.69
1.86
2.04
2.23
2.45
2.69
2.95
3.23
3.52
3.84
4.17
4.52
4.89
5.28
5.68

937
954
972
992
1014
1038
1064
1091
1120
1151
1183
1217
1252
1289
1328
-

1.71
1.85
2.02
2.20
2.39
2.61
2.85
3.11
3.39
3.68
4.00
4.33
4.68
5.05
5.44
-

Standard 3 HP & Drive
980
1.86 1023 2.02
997
2.01 1039 2.16
1016 2.17 1058 2.32
1036 2.35 1078 2.50
1058 2.55 1100 2.70
1082 2.77 1124 2.92
1107 3.01 1149 3.16
1134 3.26 1177 3.42
1163 3.54 1206 3.69
1194 3.84 1236 3.99
1226 4.15 1269 4.30
1260 4.48 1302 4.64
1296 4.84 1338 4.99
1333 5.20 1375 5.36
1371 5.59 1413 5.74
5 HP & Field Supplied Drive

1064
1080
1099
1119
1141
1165
1190
1218
1247
1277
1310
1344
1379
1416
-

2.17
2.31
2.48
2.66
2.86
3.07
3.31
3.57
3.85
4.14
4.46
4.79
5.14
5.51
-

1104
1121
1139
1159
1181
1205
1231
1258
1287
1318
1350
1384
1419
1456
-

2.32
2.47
2.63
2.81
3.01
3.23
3.47
3.72
4.00
4.29
4.61
4.94
5.29
5.66
-

1144
1160
1179
1199
1221
1245
1270
1298
1327
1357
1390
1424
1459
-

2.48
2.62
2.79
2.97
3.16
3.38
3.62
3.88
4.16
4.45
4.77
5.10
5.45
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

118

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR037-150 Bottom Duct Application
ZR037 (3.0 Ton) Bottom Duct
1

Available External Static Pressure - IWG
Air
Flow
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
(CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
FS4

Standard 1.5 HP & Drive

Hi Static 1.5 HP & Drive

900

544

0.4

632

0.5

708

0.5

774

0.6

834

0.7

889

0.8

941

0.9

993

1.0

1047

1.1

1104

1.2

1000

549

0.4

637

0.5

713

0.5

779

0.6

839

0.7

894

0.8

946

0.9

998

1.0

1052

1.1

1109

1.2

1100

562

0.4

649

0.5

725

0.6

792

0.6

852

0.7

906

0.8

959

0.9

1010

1.0

1064

1.1

1121

1.2

1200

579

0.5

666

0.5

742

0.6

809

0.6

868

0.7

923

0.8

975

0.9

1027

1.0

1081

1.1

1138

1.2

1300

598

0.5

685

0.5

761

0.6

828

0.7

887

0.8

942

0.8

994

0.9

1046

1.0

1100

1.2

1157

1.3

1400

617

0.5

705

0.6

781

0.6

847

0.7

907

0.8

962

0.9

1014

1.0

1066

1.1

1119

1.2

1177

1.3

1500

637

0.6

724

0.6

800

0.7

867

0.8

927

0.8

981

0.9

1034

1.0

1085

1.1

1139

1.2

1196

1.4

FS4

1.
2.
3.
4.

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZR049 (4.0 Ton) Bottom Duct
1

Available External Static Pressure - IWG
Air
Flow
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
(CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Standard 1.5 HP & Drive

Hi Static 1.5 HP & Drive

1200

579

0.5

666

0.5

742

0.6

809

0.6

868

0.7

923

0.8

975

0.9

1027

1.0

1081

1.1

1138

1300

598

0.5

685

0.5

761

0.6

828

0.7

887

0.8

942

0.8

994

0.9

1046

1.0

1100

1.2

1157

1.2
1.3

1400

617

0.5

705

0.6

781

0.6

847

0.7

907

0.8

962

0.9

1014

1.0

1066

1.1

1119

1.2

1177

1.3

1500

637

0.6

724

0.6

800

0.7

867

0.8

927

0.8

981

0.9

1034

1.0

1085

1.1

1139

1.2

1196

1.4

1600

655

0.6

743

0.7

819

0.7

885

0.8

945

0.9

1000

1.0

1052

1.1

1104

1.2

1158

1.3

1215

1.4

1700

672

0.7

760

0.7

836

0.8

902

0.9

962

1.0

1017

1.0

1069

1.1

1121

1.2

1175

1.3

1232

1.5

1800

687

0.7

775

0.8

851

0.9

918

0.9

977

1.0

1032

1.1

1084

1.2

1136

1.3

1190

1.4

1247

1.5

1900

700

0.8

788

0.9

864

0.9

930

1.0

990

1.1

1045

1.2

1097

1.3

1149

1.4

1202

1.5

1260

1.6

2000

711

0.9

798

0.9

874

1.0

941

1.1

1000

1.2

1055

1.2

1107

1.3

1159

1.4

1213

1.6

1270

1.7

FS4

1.
2.
3.
4.

Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
kW = BHP x 0.932.
Field Supplied Drive.

ZR061 (5.0 Ton) Bottom Duct
1

Available External Static Pressure - IWG
Air
Flow
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
(CFM) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
Standard 1.5 HP & Drive

Hi Static 2 HP & Drive

1500

613

0.5

684

0.6

759

0.7

831

0.7

928

0.8

984

0.9

1042

1.0

1093

1.1

1149

1.2

1201

1.3

1600

629

0.6

700

0.6

775

0.7

847

0.8

929

0.8

985

0.9

1043

1.0

1098

1.1

1154

1.2

1206

1.3

1700

646

0.6

717

0.7

793

0.8

864

0.8

934

0.9

990

1.0

1048

1.1

1106

1.2

1161

1.3

1214

1.4

1800

666

0.7

737

0.7

812

0.8

884

0.9

943

1.0

999

1.1

1057

1.2

1116

1.3

1172

1.4

1224

1.5

1900

687

0.7

758

0.8

833

0.9

905

0.9

954

1.0

1010

1.1

1068

1.2

1128

1.3

1184

1.4

1236

1.5

2000

710

0.8

781

0.9

856

0.9

927

1.0

968

1.1

1024

1.2

1082

1.3

1142

1.4

1198

1.5

1250

1.6

2100

733

0.8

804

0.9

879

1.0

951

1.1

983

1.2

1039

1.3

1097

1.4

1157

1.5

1213

1.6

1265

1.7

2200

758

0.9

828

1.0

904

1.1

947

1.2

1000

1.3

1056

1.4

1116

1.5

1174

1.6

1229

1.7

1281

1.8

2300

783

1.0

854

1.1

929

1.1

964

1.3

1018

1.4

1075

1.5

1133

1.6

1191

1.7

1246

1.8

-

-

2400

809

1.1

879

1.2

932

1.3

983

1.4

1037

1.5

1094

1.6

1152

1.7

1209

1.8

-

-

-

-

2500

835

1.1

906

1.2

951

1.4

1001

1.5

1055

1.6

1112

1.7

1170

1.8

2 HP & Field Supplied Drive

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

119

528150-YTG-T-0514

ZR078-150 Bottom Duct Application
ZR078 (6.5 Ton) Bottom Duct
Air Flow
(CFM)
1800
2000
2200
2400
2600
2800
3000
3200
3400

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field Supplied Drive
801
0.45
874
0.65
831
0.59
903
0.78
867
0.74
940
0.93
910
0.91
983
1.10
957
1.10 1030 1.30
1009 1.32 1082 1.51
1064 1.56 1137 1.75
1122 1.82 1194 2.02
1182 2.10 1254 2.30

946
975
1012
1055
1102
1154
1208
1266
-

Standard 1.5 HP & Drive
0.82 1018 0.97 1090
0.95 1047 1.10 1119
1.10 1084 1.25 1156
1.27 1126 1.43 1199
1.47 1174 1.62 1246
1.69 1225 1.84 1298
1.92 1280 2.08 1353
2.19
-

1.11
1.24
1.39
1.57
1.76
1.98
2.22
-

Hi Static 2 HP & Drive
1163 1.25 1238 1.38
1193 1.38 1267 1.51
1229 1.53 1304 1.66
1272 1.70 1347 1.84
1320 1.89 1394 2.03
1371 2.11 1446 2.25
2 HP & Field Supplied Drive

1315
1344
1381
1424
1471
-

1.52
1.66
1.81
1.98
2.17
-

1395
1424
1461
1503
-

1.68
1.81
1.96
2.14
-

1477
1507
1543
-

1.86
1.99
2.14
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZR090 (7.5 Ton) Bottom Duct
Air Flow
(CFM)

2000
2200
2400
2600
2800
3000
3200
3400
3600
3800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
1.5 HP & Field
Supplied Drive
831
0.59
867
0.74
910
0.91
957
1.10
1009 1.32
1064 1.56
1122 1.82
1182 2.10
1244 2.41
1308 2.73

Standard 1.5 HP & Drive
903
940
983
1030
1082
1137
1194
1254
1317
1381

0.78
0.93
1.10
1.30
1.51
1.75
2.02
2.30
2.60
2.93

975
1012
1055
1102
1154
1208
1266
1326
1389
1453

0.95
1.10
1.27
1.47
1.69
1.92
2.19
2.47
2.77
3.10

1047
1084
1126
1174
1225
1280
1338
1398
1461
1525

1.10
1.25
1.43
1.62
1.84
2.08
2.34
2.62
2.93
3.25

Hi Static 3 HP & Drive
1119
1156
1199
1246
1298
1353
1410
1471
1533
1597

1.24 1193 1.38 1267
1.39 1229 1.53 1304
1.57 1272 1.70 1347
1.76 1320 1.89 1394
1.98 1371 2.11 1446
2.22 1426 2.35 1501
2.48 1484 2.61 1559
2.76 1544 2.90 1619
3.07 1606 3.20 1681
3.39
3 HP & Field Supplied Drive

1.51
1.66
1.84
2.03
2.25
2.49
2.75
3.03
3.33
-

1344
1381
1424
1471
1523
1578
1636
1696
-

1.66
1.81
1.98
2.17
2.39
2.63
2.89
3.17
-

1424
1461
1503
1551
1602
1657
1715
1775
-

1.81
1.96
2.14
2.33
2.55
2.79
3.05
3.33
-

1507
1543
1586
1634
1685
1740
1798
-

1.99
2.14
2.31
2.51
2.73
2.96
3.23
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZR102 (8.5 Ton) Bottom Duct
Air Flow
(CFM)

2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2 HP & Field
Supplied Drive
715
0.72
768
734
0.83
786
755
0.95
808
779
1.09
832
806
1.25
859
837
1.44
889
870
1.65
922
906
1.88
959
945
2.13
998
987
2.40 1040
1032 2.70 1084

Standard 2 HP & Drive
0.85
0.96
1.08
1.22
1.38
1.57
1.78
2.01
2.26
2.53
2.83

818
837
858
882
910
940
973
1009
1048
1090
1135

0.98
1.08
1.20
1.35
1.51
1.69
1.90
2.13
2.38
2.66
2.95

867
886
907
931
958
989
1022
1058
1097
1139
1184

1.09
1.20
1.32
1.46
1.63
1.81
2.02
2.25
2.50
2.78
3.07

Hi Static 3 HP & Drive
914
933
954
978
1005
1036
1069
1105
1144
1186
1231

1.21
1.31
1.44
1.58
1.74
1.93
2.13
2.36
2.61
2.89
3.18

960
1.32 1004 1.43
978
1.42 1022 1.53
1000 1.55 1044 1.65
1024 1.69 1068 1.80
1051 1.85 1095 1.96
1081 2.04 1125 2.14
1114 2.24 1158 2.35
1150 2.47 1195 2.58
1190 2.72 1234 2.83
1231 3.00 1276 3.11
1276 3.29 1320 3.40
3 HP & Field Supplied Drive

1047
1066
1087
1111
1138
1168
1202
1238
1277
1319
-

1.53
1.64
1.76
1.90
2.07
2.25
2.46
2.69
2.94
3.21
-

1089
1108
1129
1153
1181
1211
1244
1280
1319
1361
-

1.64
1.75
1.87
2.01
2.17
2.36
2.57
2.80
3.05
3.32
-

1131
1150
1171
1195
1222
1252
1286
1322
1361
1403
-

1.75
1.86
1.98
2.12
2.28
2.47
2.68
2.91
3.16
3.43
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

120

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR120 (10 Ton) Bottom Duct
Air Flow
(CFM)

2600
2800
3000
3200
3400
3600
3800
4000
4200
4400
4600

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
2 HP & Field
Supplied Drive
755
0.95
808
779
1.09
832
806
1.25
859
837
1.44
889
870
1.65
922
906
1.88
959
945
2.13
998
987
2.40 1040
1032 2.70 1084
1079 3.01 1132
1129 3.35
-

Standard 2 HP & Drive
1.08
1.22
1.38
1.57
1.78
2.01
2.26
2.53
2.83
3.15
-

858
882
910
940
973
1009
1048
1090
1135
1182
-

1.20
1.35
1.51
1.69
1.90
2.13
2.38
2.66
2.95
3.27
-

907
931
958
989
1022
1058
1097
1139
1184
1231
-

1.32
1.46
1.63
1.81
2.02
2.25
2.50
2.78
3.07
3.39
-

Hi Static 3 HP & Drive
954
1.44 1000 1.55
978
1.58 1024 1.69
1005 1.74 1051 1.85
1036 1.93 1081 2.04
1069 2.13 1114 2.24
1105 2.36 1150 2.47
1144 2.61 1190 2.72
1186 2.89 1231 3.00
1231 3.18 1276 3.29
3 HP & Field Supplied Drive

1044
1068
1095
1125
1158
1195
1234
1276
1320
-

1.65
1.80
1.96
2.14
2.35
2.58
2.83
3.11
3.40
-

1087
1111
1138
1168
1202
1238
1277
1319
-

1.76
1.90
2.07
2.25
2.46
2.69
2.94
3.21
-

1129
1153
1181
1211
1244
1280
1319
1361
-

1.87
2.01
2.17
2.36
2.57
2.80
3.05
3.32
-

1171
1195
1222
1252
1286
1322
1361
1403
-

1.98
2.12
2.28
2.47
2.68
2.91
3.16
3.43
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

ZR150 (12.5 Ton) Bottom Duct
Air Flow
(CFM)

3200
3400
3600
3800
4000
4200
4400
4600
4800
5000
5200
5400
5600
5800

Available External Static Pressure - IWG1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP
3 HP & Field
Supplied Drive
837
1.44
870
1.65
906
1.88
945
2.13
987
2.40
1032 2.70
1079 3.01
1129 3.35
1182 3.71
1237 4.08
1294 4.48
1354 4.89
1416 5.33
-

Standard 3 HP & Drive
889
922
959
998
1040
1084
1132
1182
1235
1290
1347
1407
1469
-

1.57
1.78
2.01
2.26
2.53
2.83
3.15
3.48
3.84
4.22
4.61
5.03
5.46
-

940
973
1009
1048
1090
1135
1182
1232
1285
1340
1398
1457
1519
-

1.69
1.90
2.13
2.38
2.66
2.95
3.27
3.61
3.96
4.34
4.74
5.15
5.58
-

989
1022
1058
1097
1139
1184
1231
1281
1334
1389
1446
1506
1568
-

1.81
2.02
2.25
2.50
2.78
3.07
3.39
3.72
4.08
4.46
4.85
5.27
5.70
-

1036 1.93 1081 2.04
1069 2.13 1114 2.24
1105 2.36 1150 2.47
1144 2.61 1190 2.72
1186 2.89 1231 3.00
1231 3.18 1276 3.29
1278 3.50 1324 3.61
1328 3.84 1374 3.95
1381 4.20 1426 4.31
1436 4.57 1481 4.68
1493 4.97 1539 5.08
1553 5.38 1599 5.49
5 HP & Field Supplied Drive

Hi Static 5 HP & Drive
1125
1158
1195
1234
1276
1320
1368
1418
1471
1526
1583
1643
-

2.14
2.35
2.58
2.83
3.11
3.40
3.72
4.06
4.41
4.79
5.19
5.60
-

1168
1202
1238
1277
1319
1364
1411
1461
1514
1569
1626
1686
-

2.25
2.46
2.69
2.94
3.21
3.51
3.83
4.16
4.52
4.90
5.29
5.71
-

1211
1244
1280
1319
1361
1406
1453
1503
1556
1611
1669
-

2.36
2.57
2.80
3.05
3.32
3.62
3.93
4.27
4.63
5.01
5.40
-

1252
1286
1322
1361
1403
1447
1495
1545
1598
1653
1710
-

2.47
2.68
2.91
3.16
3.43
3.73
4.05
4.38
4.74
5.12
5.51
-

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

Johnson Controls Unitary Products

121

528150-YTG-T-0514

Sound Performance
Indoor Sound Power Levels (3 thru 5 Ton)
Indoor Sound Power Levels (Horizontal Ducted Inlet, Standard Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Return) Ducted Inlet
612 - 3 Turns Open Equivalent

709 - 1 Turn Open Equivalent

0.5

0.4

Airflow (CFM)

850

1300

Blower Motor BHP

0.37

External Static Pressure (IWG)

0.40

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation1 (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

73

77

73

77

125

61

70

66

71

250

56

63

60

64

500

51

56

55

57

1000

44

48

51

52

2000

41

44

48

49

4000

44

47

47

48

8000

42

44

43

44

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Return) Ducted Inlet
612 - 3 Turns Open Equivalent

709 - 1 Turn Open Equivalent

External Static Pressure (IWG)

0.5

0.4

Airflow (CFM)

850

1300

Blower Motor BHP

0.37

Octave Center Freq. Hz

ID Blower Only (dB)

0.40
Cooling

Operation1

(dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

73

77

73

77

125

61

70

66

71

250

56

63

60

64

500

51

56

55

57

1000

44

48

51

52

2000

41

44

48

49

4000

44

47

47

48

8000

42

44

43

44

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

122

Johnson Controls Unitary Products

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive

TEST CONFIGURATION

Horizontal (Side Return) Ducted Inlet

Indoor Blower Speed (RPM)

814 - 3 Turns Open Equivalent

918 - 1 Turn Open Equivalent

0.6

0.8

Airflow (CFM)

1700

1950

Blower Motor BHP

0.42

External Static Pressure (IWG)

0.88

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation1 (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

77

81

85

82

125

71

80

68

81

250

63

67

64

68

500

58

60

60

61

1000

56

57

58

59

2000

52

53

55

55

4000

51

51

54

54

8000

47

47

48

48

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Indoor Sound Power Levels (Horizontal Ducted Discharge, Standard Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive

TEST CONFIGURATION

Horizontal (Side Supply) Ducted Discharge

Indoor Blower Speed (RPM)

610 - 3 Turns Open Equivalent

710 - 1 Turn Open Equivalent

External Static Pressure (IWG)

0.5

0.6

Airflow (CFM)

850

950

Blower Motor BHP

0.37

Octave Center Freq. Hz

ID Blower Only (dB)

0.42
Cooling

Operation1

(dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

77

78

79

79

125

74

75

75

76

250

66

68

70

70

500

61

61

65

64

1000

60

62

65

66

2000

52

52

58

58

4000

52

52

59

60

8000

44

44

50

50

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Johnson Controls Unitary Products

123

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Supply) Ducted Discharge
610 - 3 Turns Open Equivalent

710 - 1 Turn Open Equivalent

0.5

0.6

External Static Pressure (IWG)
Airflow (CFM)

850

950

Blower Motor BHP

0.37

0.42

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation1 (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

77

78

79

79

125

74

75

75

76

250

66

68

70

70

500

61

61

65

64

1000

60

62

65

66

2000

52

52

58

58

4000

52

52

59

60

8000

44

44

50

50

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Supply) Ducted Discharge
810 - 3 Turns Open Equivalent

External Static Pressure (IWG)

918 - 1 Turn Open Equivalent

0.4

0.8

Airflow (CFM)

2050

1950

Blower Motor BHP

0.73

0.88
1

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

85

83

83

83

125

78

79

76

79

250

69

70

69

70

500

68

68

68

68

1000

64

64

65

65

2000

63

63

64

64

4000

64

64

64

64

8000

59

59

59

60

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

124

Johnson Controls Unitary Products

528150-YTG-T-0514

Indoor Sound Power Levels (Vertical Ducted Inlet, Standard Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive

TEST CONFIGURATION

Vertical (Bottom Return) Ducted Inlet

Indoor Blower Speed (RPM)

609 - 3 Turns Open Equivalent

708 - 1 Turn Open Equivalent

0.4

0.4

Airflow (CFM)

850

1150

Blower Motor BHP

0.32

External Static Pressure (IWG)

0.38

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation1 (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

76

76

74

76

125

63

70

66

70

250

55

62

59

62

500

54

55

58

59

1000

48

48

53

53

2000

44

44

48

48

4000

41

44

45

46

8000

42

43

43

44

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive

TEST CONFIGURATION

Vertical (Bottom Return) Ducted Inlet
609 - 3 Turns Open Equivalent

Indoor Blower Speed (RPM)

708 - 1 Turn Open Equivalent

External Static Pressure (IWG)

0.4

0.4

Airflow (CFM)

850

1150

Blower Motor BHP

0.32

Octave Center Freq. Hz

ID Blower Only (dB)

0.38
Cooling

Operation1

(dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

76

76

74

76

125

63

70

66

70

250

55

62

59

62

500

54

55

58

59

1000

48

48

53

53

2000

44

44

48

48

4000

41

44

45

46

8000

42

43

43

44

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Johnson Controls Unitary Products

125

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Vertical (Bottom Return) Ducted Inlet
812 - 3 Turns Open Equivalent

915- 1 Turn Open Equivalent

0.6

0.8

Airflow (CFM)

1575

1800

Blower Motor BHP

0.64

External Static Pressure (IWG)

Octave Center Freq. Hz

ID Blower Only (dB)

0.83
Cooling Operation1 (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

75

78

80

80

125

66

80

69

81

250

59

66

62

65

500

60

60

63

63

1000

57

57

60

60

2000

52

53

55

55

4000

49

50

53

53

8000

44

45

47

47

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Indoor Sound Power Levels (Vertical Ducted Discharge, Standard Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / Standard Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Vertical (Bottom Supply) Ducted Discharge
609 - 3 Turns Open Equivalent

712 - 1 Turn Open Equivalent

External Static Pressure (IWG)

0.4

0.6

Airflow (CFM)

850

950

Blower Motor BHP

0.32

0.42
1

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

76

77

81

81

125

68

68

72

72

250

55

65

57

57

500

56

57

57

57

1000

51

57

52

56

2000

49

49

50

50

4000

48

48

49

51

8000

46

46

47

48

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

126

Johnson Controls Unitary Products

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / Standard Static Belt Drive

TEST CONFIGURATION

Vertical (Bottom Supply) Ducted Discharge

Indoor Blower Speed (RPM)

609 - 3 Turns Open Equivalent

712 - 1 Turn Open Equivalent

0.4

0.6

External Static Pressure (IWG)
Airflow (CFM)

850

950

Blower Motor BHP

0.32

0.42

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation1 (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

76

77

81

81

125

68

68

72

72

250

55

65

57

57

500

56

57

57

57

1000

51

57

52

56

2000

49

49

50

50

4000

48

48

49

51

8000

46

46

47

48

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / Standard Static Belt Drive

TEST CONFIGURATION

Vertical (Bottom Supply) Ducted Discharge

Indoor Blower Speed (RPM)

809 - 3 Turns Open Equivalent

External Static Pressure (IWG)

914 - 1 Turn Open Equivalent

0.5

0.8

Airflow (CFM)

1700

1800

Blower Motor BHP

0.64

0.83
1

Octave Center Freq. Hz

ID Blower Only (dB)

Cooling Operation (dB)

ID Blower Only (dB)

Cooling Operation1 (dB)

63

81

81

79

79

125

75

75

75

76

250

65

65

63

63

500

67

67

67

67

1000

63

63

63

63

2000

61

62

61

61

4000

62

62

61

61

8000

57

57

56

56

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Johnson Controls Unitary Products

127

528150-YTG-T-0514

Indoor Sound Power Levels (Horizontal Ducted Inlet, High Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive

TEST CONFIGURATION

Horizontal (Side Return) Ducted Inlet
876 - 4 Turns Open Equivalent

1,064 - 1/2 Turn Open Equivalent

1,190 - 2.5 Turns Open Equivalent1

1.0

1.6

2.0 1

Nominal Airflow (CFM)

1,200

1,100

1,000

Blower Motor BHP

0.64

0.93

Indoor Blower Speed (RPM)
External Static Pressure (IWG)

1.08

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

63

75

80

81

81

81

83

125

69

71

71

73

73

75

250

62

68

66

71

68

70

500

54

56

57

59

59

60

1000

52

56

56

58

58

60

2000

47

49

52

52

54

56

4000

43

45

48

49

51

53

8000

43

45

45

46

47

48

1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69.
2. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Return) Ducted Inlet
965 - 5.5 Turns Open Equivalent

1,088 - 4 Turns Open Equivalent

1.0

1.6

2.0

Nominal Airflow (CFM)

1,600

1,400

1,200

Blower Motor BHP

0.86

1.03

1.13

External Static Pressure (IWG)

1,186 - 2.5 Turns Open Equivalent

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

74

80

77

80

81

81

125

69

74

72

75

75

76

250

68

68

68

69

70

71

500

62

62

60

61

61

63

1000

60

61

58

58

59

60

2000

57

57

53

54

55

56

4000

56

56

49

50

51

52

8000

54

54

45

47

47

48

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

128

Johnson Controls Unitary Products

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Return) Ducted Inlet
1,012- 5.5 Turns Open Equivalent

1,134 - 3 Turns Open Equivalent

1,174 - 2 Turns Open Equivalent

1.0

1.6

2.0

Nominal Airflow (CFM)

2,000

1,800

1,600

Blower Motor BHP

1.04

1.25

External Static Pressure (IWG)

1.39

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

76

78

78

79

79

81

125

70

73

73

76

74

77

250

68

70

68

69

69

70

500

61

62

61

62

60

62

1000

61

62

61

62

58

60

2000

57

58

57

58

54

56

4000

56

56

55

56

52

53

8000

50

50

50

50

47

48

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Indoor Sound Power Levels (Horizontal Ducted Discharge, High Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive
Horizontal (Side Supply) Ducted Discharge

TEST CONFIGURATION

896 - 3.5 Turns Open Equivalent

1,072 - Fully Closed Equivalent

1,170 - 2.5 Turns Open Equivalent1

1.0

1.6

2.0 1

Nominal Airflow (CFM)

1,200

1,100

1,000

Blower Motor BHP

0.64

0.93

1.08

Indoor Blower Speed (RPM)
External Static Pressure (IWG)

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

63

77

81

83

84

83

84

125

74

76

76

77

80

80

250

67

68

70

70

72

73

500

65

66

67

67

67

68

1000

61

62

67

67

66

69

2000

58

60

63

63

63

64

4000

57

59

62

62

62

63

8000

51

53

56

57

56

58

1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69.
2. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Johnson Controls Unitary Products

129

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Horizontal (Side Supply) Ducted Discharge
922 - 6 Turns Open Equivalent

1,069 - 4 Turns Open Equivalent

1,165 - 2.5 Turns Open Equivalent

1.0

1.6

2.0

Nominal Airflow (CFM)

1,600

1,400

1,200

Blower Motor BHP

0.86

1.03

External Static Pressure (IWG)

1.13

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

80

82

82

83

84

84

125

76

77

76

77

78

79

250

71

72

72

72

74

74

500

69

69

69

69

70

70

1000

65

65

69

69

70

70

2000

64

64

64

64

65

65

4000

63

63

63

63

64

64

8000

58

58

58

58

59

59

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive
Horizontal (Side Supply) Ducted Discharge

TEST CONFIGURATION
Indoor Blower Speed (RPM)

1,009- 5.5 Turns Open Equivalent

1,131 - 3 Turns Open Equivalent

1.0

1.6

2.0

2,000

1,800

1,600

External Static Pressure (IWG)
Nominal Airflow (CFM)
Blower Motor BHP
Octave Center Freq. Hz

1.04
ID Blower
Only (dB)

1,184 - 2 Turns Open Equivalent

1.25

Cooling
Operation1 (dB)

ID Blower
Only (dB)

1.39

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

84

85

82

83

82

83

125

78

79

79

79

78

79

250

75

75

74

75

73

73

500

71

71

70

71

69

69

1000

69

69

71

71

71

72

2000

66

67

67

67

66

66

4000

66

66

66

67

66

66

8000

61

62

61

62

60

60

1. Cooling Operation – ID blower, compressor and outdoor fan operating at 230 VAC.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

130

Johnson Controls Unitary Products

528150-YTG-T-0514

Indoor Sound Power Levels (Vertical Ducted Inlet, High Static Belt Drive)
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive

TEST CONFIGURATION

Vertical (Bottom Return) Ducted Inlet
927 - 3 Turns Open Equivalent

1,085 - 1/2 Turn Open Equivalent

1,190 - 2.5 Turns Open Equivalent1

1.0

1.6

2.01

Nominal Airflow (CFM)

1,200

1,100

1,000

Blower Motor BHP

0.68

0.93

1.09

Indoor Blower Speed (RPM)
External Static Pressure (IWG)

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

63

77

79

82

83

79

81

125

68

69

70

71

72

73

250

60

67

62

69

64

67

500

58

58

63

63

62

63

1000

54

55

60

60

60

60

2000

48

49

56

56

55

55

4000

43

44

48

49

51

51

8000

44

44

45

46

47

47

1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69.
2. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Vertical (Bottom Return) Ducted Inlet
968 - 5.5 Turns Open Equivalent

1,120 - 3.5 Turns Open Equivalent

1,218 - 2.0 Turns Open Equivalent

1.0

1.6

2.0

Nominal Airflow (CFM)

1,600

1,400

1,200

Blower Motor BHP

0.86

1.03

1.13

External Static Pressure (IWG)

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

77

79

78

78

81

81

125

69

73

71

73

73

74

250

63

63

63

64

66

66

500

63

64

62

63

64

64

1000

59

59

59

59

61

61

2000

54

54

53

54

56

56

4000

49

49

48

48

50

51

8000

45

46

45

46

47

47

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Johnson Controls Unitary Products

131

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Vertical (Bottom Return) Ducted Inlet
1,039 - 5 Turns Open Equivalent

1,143 - 3 Turns Open Equivalent

1,201 - 2 Turns Open Equivalent

1.0

1.6

2.0

Nominal Airflow (CFM)

2,000

1,800

1,600

Blower Motor BHP

1.11

1.25

External Static Pressure (IWG)

1.39

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

79

80

77

77

81

81

125

74

75

71

73

73

74

250

63

65

63

64

63

65

500

62

63

64

64

62

62

1000

61

61

61

61

59

59

2000

55

56

55

56

54

55

4000

52

52

50

51

50

50

8000

47

47

46

46

46

46

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Indoor Sound Power Levels (Vertical Ducted Discharge, High Static Belt Drive)

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR037 / 3 Ton / High Static Belt Drive

TEST CONFIGURATION

Vertical (Bottom Supply) Ducted Discharge
920 - 3.0 Turns Open Equivalent

1,074 - Fully Closed Equivalent

1,189 - 2.0 Turns Open Equivalent1

1.0

1.6

2.01

Nominal Airflow (CFM)

1,200

1,100

1,000

Blower Motor BHP

0.68

0.93

1.09

Indoor Blower Speed (RPM)
External Static Pressure (IWG)

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

ID Blower
Only (dB)

Cooling
Operation2 (dB)

63

81

82

81

81

82

82

125

78

78

78

78

81

81

250

69

70

70

71

74

74

500

67

68

68

69

71

71

1000

62

63

67

68

70

71

2000

60

61

62

63

65

66

4000

61

61

63

63

66

66

8000

54

55

57

57

60

61

1. Requires driven pulley #AK-56, normal high static pulley is an #AK-69.
2. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

132

Johnson Controls Unitary Products

528150-YTG-T-0514

UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR049 / 4 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Vertical (Bottom Supply) Ducted Discharge
962 - 5.5 Turns Open Equivalent

1,092 - 3.5 Turns Open Equivalent

1,190 - 2.0 Turns Open Equivalent

1.0

1.6

2.0

Nominal Airflow (CFM)

1,600

1,400

1,200

Blower Motor BHP

0.86

1.03

External Static Pressure (IWG)

1.13

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

83

84

82

82

83

83

125

80

81

79

80

80

81

250

75

75

74

75

75

75

500

71

72

70

71

71

72

1000

66

67

70

71

72

72

2000

63

64

64

64

65

65

4000

64

64

64

64

65

66

8000

58

59

59

59

60

60

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.
UNIT DESCRIPTION / MODEL

ZH/ZJ/ZR061 / 5 Ton / High Static Belt Drive

TEST CONFIGURATION
Indoor Blower Speed (RPM)

Vertical (Bottom Supply) Ducted Discharge
1,033 - 5.5 Turns Open Equivalent

1,135 - 3 turns Open Equivalent

1.0

1.6

2.0

2,000

1,135

1,175

External Static Pressure (IWG)
Nominal Airflow (CFM)
Blower Motor BHP

1.11

1,175 - 2.5 Turns Open Equivalent

1.25

1.39

Octave Center Freq. Hz

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

ID Blower
Only (dB)

Cooling
Operation1 (dB)

63

83

83

83

83

85

86

125

84

84

82

82

79

81

250

79

80

77

78

66

66

500

73

73

70

71

65

66

1000

69

70

69

70

61

65

2000

67

67

65

66

60

61

4000

67

68

66

67

61

62

8000

62

63

60

61

54

54

1. Differentials for Cooling Operation (IDB, COMP, & ODF) are logarithmically calculated from the horizontal flow sound test.
• Tested in accordance with AHRI Standard 260-2001. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning
Equipment.
• Testing datum includes effect of standard inlet air filters.
• Test duct dimension: 18 in. wide x 28 in. high x 8 ft. long, no elbows.
• Test duct termination is flush with reverberant room wall.
• Duct end (sound reflection) corrections included: (7.2, 3.4, 1.2, 0.4, 0.1, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 2k, 4k, 8k) Hz respectively.

Johnson Controls Unitary Products

133

528150-YTG-T-0514

Indoor Sound Power Levels (6.5 thru 12.5 Ton)
Size
(Tons)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)

Model

CFM

ESP
(IWG)

Blower
RPM

BHP

Sound Rating1
dB (A)

63

Sound Power, dB (10-12) Watts
Octave Band Centerline Frequency (Hz)
125
250
500
1000
2000
4000

8000

ZH/ZJ/ZR

2600

0.6

812

1.14

74

71

73

73

71

69

65

65

60

ZH/ZJ/ZR

3000

0.6

854

1.47

77

74

76

76

74

72

68

68

63

ZH/ZJ/ZR

3400

0.6

872

1.65

80

77

79

79

77

75

71

71

66

ZH/ZJ/ZR

4000

0.6

959

2.29

83

80

82

82

80

78

74

74

69

ZH/ZJ/ZR

5000

0.6

1132

3.74

87

84

86

86

84

82

78

78

73

1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values
provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way
of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data
in any other form than sound power level ratings.

134

Johnson Controls Unitary Products

528150-YTG-T-0514
Outdoor Sound Power Levels
ZH/ZJ/ZR037-150
Size
(Tons)
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)
037
(3)
049
(4)
61
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)

Model

Sound Rating1
dB (A)

63

125

ZH

81

82.5

86.5

78.0

75.5

76.5

ZH

78

82.0

86.0

78.5

75.5

ZH

84

81.0

91.0

82.5

ZH

87

89.0

88.5

ZH

92

93.0

ZH

92

ZH

Octave Band Centerline Frequency (Hz)
250
500
1000
2000

4000

8000

68.5

63.0

56.5

73.0

68.0

63.0

56.0

80.5

79.0

73.5

69.5

64.5

84.5

84.5

82.0

76.5

72.0

66.5

92.0

90.5

88.0

86.5

83.0

77.5

73.5

97.0

94.0

93.5

90.5

87.0

81.5

76.0

69.0

91

99.5

91.5

91.5

89.0

86.0

80.5

76.5

71.0

ZH

86

89.5

91.0

85.5

84.0

81.0

76.5

71.0

62.5

ZJ

77

82.0

83.5

80.0

73.0

70.0

65.5

60.5

55.5

ZJ

80

80.0

87.0

77.0

75.5

75.0

70.5

65.5

62.0

ZJ

84

86.5

87.0

86.0

79.0

76.5

71.5

68.0

64.0

ZJ

85

87.5

85.0

84.0

82.0

80.0

75.5

71.5

67.0

ZJ

90

90.0

93.0

90.5

86.0

83.5

81.5

78.0

75.0

ZJ

92

97.0

94.0

93.5

90.5

87.0

81.5

76.0

69.0

ZJ

91

99.5

91.5

91.5

89.0

86.0

80.5

76.5

71.0

ZJ

85

89.0

88.0

83.5

83.5

78.5

74.0

69.5

64.5

ZR

77

82.0

83.5

80.0

73.0

70.0

65.5

60.5

55.5

ZR

81

87.5

88.5

83.0

77.5

73.5

70.5

67.0

62.0

ZR

84

86.5

87.0

86.0

79.0

76.5

71.5

68.0

64.0

ZR

83

~

88.0

82.5

81.5

78.0

73.0

69.0

62.0

ZR

83

~

89.5

83.5

82.0

78.0

72.5

68.0

60.5

ZR

83

~

89.0

84.5

81.5

78.0

72.5

68.5

70.5

ZR

83

~

89.5

83.5

81.0

78.0

72.0

68.5

70.5

ZR

84

~

90.0

84.5

81.5

77.5

72.0

68.5

61.5

1. Rated in accordance with AHRI 270 standard.

Johnson Controls Unitary Products

135

528150-YTG-T-0514

Electrical Data
ZH037-061 Standard Indoor Blower - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.1

68

14.2

1.5

6.0

5.5

0.0

230

9.1

68

14.2

1.5

6.0

5.5

0.0

460

4.5

34

7

0.8

3.0

2.2

0.0

575

3.8

28

6

0.6

2.4

1.8

0.0

208

11.2

88

17.5

1.5

6.0

5.5

0.0

230

11.2

88

17.5

1.5

6.0

5.5

0.0

460

5.6

44

8.0

0.8

3.0

2.2

0.0

575

4.5

36

7.0

0.6

2.4

1.8

0.0

208

14.1

88

22

1.5

6.0

5.5

0.0

230

14.1

88

22

1.5

6.0

5.5

0.0

460

7.7

55

12

0.8

3.0

2.2

0.0

575

5.1

36

7.5

0.6

2.4

1.8

0.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA1
(Amps)

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

18.9
18.9
23.1
31.1
46.7
18.9
18.9
25.5
34.6
52.6
9.4
9.4
12.8
17.3
26.3
7.8
13.8
21
21.5
23.1
31.1
46.7
59.5
21.7
25.5
34.6
52.6
67.6
10.8
12.8
17.3
26.3
33.8
8.6
13.8
21
27.1
26.6
26.6
31.1
46.7
59.5
70
26.6
26.6
34.6
52.6
67.6
79.7
14.2
14.2
17.3
26.3
33.8
39.8
10
13.8
21
27.1
31.9

MCA1
w/Pwr
Exh
(Amps)
24.4
24.4
30
38
53.6
24.4
24.4
32.4
41.4
59.5
11.6
11.6
15.5
20
29.1
9.6
16.1
23.3
27
30
38
53.6
66.4
27
32.4
41.4
59.5
74.5
13
15.5
20
29.1
36.6
10.4
16.1
23.3
29.3
32.1
32.1
38
53.6
66.4
76.8
32.1
32.4
41.4
59.5
74.5
86.5
16.4
16.4
20
29.1
36.6
42.6
11.8
16.1
23.3
29.3
34.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
25
30
25
30
25
30
35
40
50
60
25
30
25
30
30
35
35
45
60
60
15
15
15
15
15
20
20
20
30
30
15
15
15
20
25
25
30
35
30
35
35
40
50
60
60
70
30
35
30
35
35
45
60
60
70
80
15
15
15
20
20
20
30
30
35
40
15
15
15
20
25
25
30
30
35
45
35
45
40
45
50
60
60
70
70
80
35
45
35
45
40
45
60
60
70
80
80
90
20
20
20
20
20
20
30
30
35
40
40
45
15
15
15
20
25
25
30
30
35
35

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

136

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH078-150 Standard Motor - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.0

5.5

0.0

230

9.3

68

14.5

1.5

6.0

5.5

0.0

460

4.9

34

7.7

0.8

3.0

2.2

0.0

575

3.8

28

6

0.6

2.4

1.8

0.0

208

11.9

88

18.5

3.5

6.0

5.5

0.0

230

11.9

88

18.5

3.5

6.0

5.5

0.0

460

5.2

44

8.1

1.6

3.0

2.2

0.0

575

4.8

36

7.5

1.3

2.4

1.8

0.0

208

12.2

88

19

3.5

6.8

5.5

0.0

230

12.2

88

19

3.5

6.8

5.5

0.0

460

5.8

44

9

1.6

3.4

2.2

0.0

575

4.4

36

5.5

1.3

2.7

1.8

0.0

078
(6.5)

090
(7.5)

102
(8.5)

Johnson Controls Unitary Products

Electric Heat Option
Model

kW

Stages

Amps

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

29.9
31.1
54.3
70
96
29.9
34.6
61.6
79.7
109.7
15.6
17.3
30.8
39.8
54.9
12.2
13.8
24.7
31.9
43.9
39.8
39.8
54.3
70
96
39.8
39.8
61.6
79.7
109.7
17.9
17.9
30.8
39.8
54.9
15.8
15.8
24.7
31.9
43.9
41.3
41.3
55.3
71
97
41.3
41.3
62.6
80.7
110.7
19.7
19.7
31.3
40.3
55.4
15.2
15.2
25
32.2
44.3

35.4
38
61.2
76.8
102.9
35.4
41.4
68.5
86.5
116.6
17.8
20
33.6
42.6
57.6
14
16.1
26.9
34.1
46.1
45.3
45.3
61.2
76.8
102.9
45.3
45.3
68.5
86.5
116.6
20.1
20.1
33.6
42.6
57.6
17.6
17.6
26.9
34.1
46.1
46.8
46.8
62.2
77.8
103.9
46.8
46.8
69.5
87.5
117.6
21.9
21.9
34.1
43.1
58.1
17
17
27.3
34.5
46.5

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
40
35
40
60
70
70
80
100
110
35
40
35
45
70
70
80
90
110
125
20
20
20
20
35
35
40
45
60
60
15
15
15
20
25
30
35
35
45
50
50
50
50
50
60
70
70
80
100
110
50
50
50
50
70
70
80
90
110
125
20
25
20
25
35
35
40
45
60
60
20
20
20
20
25
30
35
35
45
50
50
50
50
50
60
70
80
80
100
110
50
50
50
50
70
70
90
90
125
125
25
25
25
25
35
35
45
45
60
60
20
20
20
20
25
30
35
35
45
50

137

528150-YTG-T-0514
ZH078-150 Standard Motor - Without Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

3.5

6.8

5.5

0.0

230

16.0 110.0 24.9

3.5

6.8

5.5

0.0

460

7.8

52.0

12.1

1.6

3.4

2.2

0.0

575

5.7

38.9

8.9

1.3

2.7

1.8

0.0

208

23.1

160

36

1.5

9.6

5.5

0.0

230

23.1

160

36

1.5

9.6

5.5

0.0

460

12.2

87

19

0.8

4.8

2.2

0.0

575

8.7

62

13.5

0.6

3.9

1.8

0.0

120
(10)

150
(12.5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

49.8
55.3
71.0
97.0
149.4
49.8
62.6
80.7
110.7
138.4
24.2
31.3
40.3
55.4
69.2
18.1
25.0
32.2
44.3
55.3
67.6
67.6
74.5
100.5
152.9
67.6
67.6
84.2
114.2
141.9
35.5
35.5
42.1
57.1
71
25.9
26.5
33.7
45.8
56.8

55.3
62.2
77.8
103.9
156.2
55.3
69.5
87.5
117.6
145.3
26.4
34.1
43.1
58.1
72.0
19.9
27.3
34.5
46.5
57.6
73.1
73.1
81.3
107.4
159.7
73.1
73.1
91
121.1
148.8
37.7
37.7
44.8
59.9
73.7
27.7
28.8
36
48
59.1

1

Model

kW

Stages

Amps

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
60
70
60
70
80
80
100
110
150
175
60
70
70
70
90
90
125
125
150
175
30
30
35
35
45
45
60
60
80
80
20
25
25
30
35
35
45
50
60
60
90
90
90
90
90
90
110
110
175
175
90
90
90
90
90
100
125
125
175
175
45
45
45
45
45
45
60
60
80
80
30
35
30
35
35
40
50
50
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

138

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.1

68

14.2

1.5

6.0

5.5

0.0

230

9.1

68

14.2

1.5

6.0

5.5

0.0

460

4.5

34

7

0.8

3.0

2.2

0.0

575

3.8

28

6

0.6

2.4

1.8

0.0

208

11.2

88

17.5

1.5

6.0

5.5

0.0

230

11.2

88

17.5

1.5

6.0

5.5

0.0

460

5.6

44

8.0

0.8

3.0

2.2

0.0

575

4.5

36

7.0

0.6

2.4

1.8

0.0

208

14.1

88

22

1.5

6.8

5.5

0.0

230

14.1

88

22

1.5

6.8

5.5

0.0

460

7.7

55

12

0.8

3.4

2.2

0.0

575

5.1

36

7.5

0.6

2.7

1.8

0.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

18.9
18.9
23.1
31.1
46.7
18.9
18.9
25.5
34.6
52.6
9.4
9.4
12.8
17.3
26.3
7.8
13.8
21
21.5
23.1
31.1
46.7
59.5
21.5
25.5
34.6
52.6
67.6
10.8
12.8
17.3
26.3
33.8
8.6
13.8
21
27.1
27.4
27.4
32.1
47.7
60.5
71
27.4
27.4
35.6
53.6
68.6
80.7
14.6
14.6
17.8
26.8
34.3
40.3
10.3
14.2
21.4
27.4
32.2

24.4
24.4
30
38
53.6
24.4
24.4
32.4
41.4
59.5
11.6
11.6
15.5
20
29.1
9.6
16.1
23.3
27
30
38
53.6
66.4
27
32.4
41.4
59.5
74.5
13
15.5
20
29.1
36.6
10.4
16.1
23.3
29.3
32.9
32.9
39
54.6
67.4
77.8
32.9
33.4
42.4
60.5
75.5
87.5
16.8
16.8
20.5
29.6
37.1
43.1
12.1
16.5
23.7
29.7
34.5

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
25
30
25
30
25
30
35
40
50
60
25
30
25
30
30
35
35
45
60
60
15
15
15
15
15
20
20
20
30
30
15
15
15
20
25
25
30
35
30
35
35
40
50
60
60
70
30
35
30
35
35
45
60
60
70
80
15
15
15
20
20
20
30
30
35
40
15
15
15
20
25
25
30
30
35
45
35
45
40
45
50
60
70
70
80
80
35
45
35
45
40
45
60
70
70
80
90
90
20
20
20
20
20
25
30
30
35
40
45
45
15
15
15
20
25
25
30
30
35
35

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

139

528150-YTG-T-0514

ZH078-150 Hi Static Motor - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.8

5.5

0.0

230

9.3

68

14.5

1.5

6.8

5.5

0.0

460

4.9

34

7.7

0.8

3.4

2.2

0.0

575

3.8

28

6

0.6

2.7

1.8

0.0

208

11.9

88

18.5

3.5

9.6

5.5

0.0

230

11.9

88

18.5

3.5

9.6

5.5

0.0

460

5.2

44

8.1

1.6

4.8

2.2

0.0

575

4.8

36

7.5

1.3

3.9

1.8

0.0

208

12.2

88

19

3.5

9.6

5.5

0.0

230

12.2

88

19

3.5

9.6

5.5

0.0

460

5.8

44

9

1.6

4.8

2.2

0.0

575

4.4

36

5.5

1.3

3.9

1.8

0.0

078
(6.5)

090
(7.5)

102
(8.5)

140

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

30.7
32.1
55.3
71
97
30.7
35.6
62.6
80.7
110.7
16
17.8
31.3
40.3
55.4
12.5
14.2
25
32.2
44.3
43.4
43.4
58.8
74.5
100.5
43.4
43.4
66.1
84.2
114.2
19.7
19.7
33.1
42.1
57.1
17.3
17.3
26.5
33.7
45.8
44.1
44.1
58.8
74.5
100.5
44.1
44.1
66.1
84.2
114.2
21.1
21.1
33.1
42.1
57.1
16.4
16.4
26.5
33.7
45.8

36.2
39
62.2
77.8
103.9
36.2
42.4
69.5
87.5
117.6
18.2
20.5
34.1
43.1
58.1
14.3
16.5
27.3
34.5
46.5
48.9
48.9
65.7
81.3
107.4
48.9
48.9
73
91
121.1
21.9
22.3
35.8
44.8
59.9
19.1
19.1
28.8
36
48
49.6
49.6
65.7
81.3
107.4
49.6
49.6
73
91
121.1
23.3
23.3
35.8
44.8
59.9
18.2
18.2
28.8
36
48

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
40
45
40
45
60
70
80
80
100
110
40
45
40
45
70
70
90
90
125
125
20
20
20
25
35
35
45
45
60
60
15
15
15
20
25
30
35
35
45
50
50
60
50
60
60
70
80
90
110
110
50
60
50
60
70
80
90
100
125
125
20
25
20
25
35
40
45
45
60
60
20
20
20
20
30
30
35
40
50
50
50
60
50
60
60
70
80
90
110
110
50
60
50
60
70
80
90
100
125
125
25
25
25
25
35
40
45
45
60
60
20
20
20
20
30
30
35
40
50
50

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

3.5

9.6

5.5

0.0

230

16.0 110.0 24.9

3.5

9.6

5.5

0.0

460

7.8

52.0

12.1

1.6

4.8

2.2

0.0

575

5.7

38.9

8.9

1.3

3.9

1.8

0.0

208

23.1

160

36

1.5

15.2

5.5

0.0

230

23.1

160

36

1.5

15.2

5.5

0.0

460

12.2

87

19

0.8

7.6

2.2

0.0

575

8.7

62

13.5

0.6

6.1

1.8

0.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

52.6
58.8
74.5
100.5
152.9
52.6
66.1
84.2
114.2
141.9
25.6
33.1
42.1
57.1
71.0
19.3
26.5
33.7
45.8
56.8
73.2
73.2
81.5
107.5
159.9
73.2
73.2
91.2
121.2
148.9
38.3
38.3
45.6
60.6
74.5
28.1
29.3
36.5
48.5
59.6

58.1
65.7
81.3
107.4
159.7
58.1
73.0
91.0
121.1
148.8
27.8
35.8
44.8
59.9
73.7
21.1
28.8
36.0
48.0
59.1
78.7
78.7
88.3
114.4
166.7
78.7
80
98
128.1
155.8
40.5
40.5
48.3
63.4
77.2
29.9
31.5
38.7
50.8
61.8

1

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
60
70
60
70
80
90
110
110
175
175
60
70
70
80
90
100
125
125
175
175
30
35
35
40
45
45
60
60
80
80
25
25
30
30
35
40
50
50
70
70
90
100
90
100
90
100
110
125
175
175
90
100
90
100
100
100
125
150
175
175
50
50
50
50
50
50
70
70
90
90
35
35
35
35
40
40
50
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

141

528150-YTG-T-0514

ZH037-061 Standard Indoor Blower - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.1

68

14.2

1.5

6.0

5.5

10.0

230

9.1

68

14.2

1.5

6.0

5.5

10.0

460

4.5

34

7

0.8

3.0

2.2

5.0

575

3.8

28

6

0.6

2.4

1.8

4.0

208

11.2

88

17.5

1.5

6.0

5.5

10.0

230

11.2

88

17.5

1.5

6.0

5.5

10.0

460

5.6

44

8.0

0.8

3.0

2.2

5.0

575

4.5

36

7.0

0.6

2.4

1.8

4.0

208

14.1

88

22

1.5

6.0

5.5

10.0

230

14.1

88

22

1.5

6.0

5.5

10.0

460

7.7

55

12

0.8

3.0

2.2

5.0

575

5.1

36

7.5

0.6

2.4

1.8

4.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

29.1
29.1
35.6
43.6
59.2
29.1
29.1
38
47.1
65.1
14.6
14.6
19
23.5
32.6
11.8
18.8
26
31.5
35.6
43.6
59.2
72
31.5
38
47.1
65.1
80.1
15.8
19
23.5
32.6
40.1
12.6
18.8
26
32.1
36.6
36.6
43.6
59.2
72
82.5
36.6
38
47.1
65.1
80.1
92.2
19.2
19.2
23.5
32.6
40.1
46.1
14
18.8
26
32.1
36.9

34.6
34.9
42.5
50.5
66.1
34.6
35.9
44.9
53.9
72
16.8
17.3
21.8
26.3
35.3
13.6
21.1
28.3
37
42.5
50.5
66.1
78.9
37
44.9
53.9
72
87
18
21.8
26.3
35.3
42.8
14.4
21.1
28.3
34.3
42.1
42.5
50.5
66.1
78.9
89.3
42.1
44.9
53.9
72
87
99
21.4
21.8
26.3
35.3
42.8
48.8
15.8
21.1
28.3
34.3
39.1

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15.0
6.0
9.0
15.0
20.0
6.0
9.0
15.0
20.0
9.0
15.0
20.0
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
40
35
40
40
45
45
60
60
70
35
40
35
40
40
45
50
60
70
80
15
20
15
20
20
25
25
30
35
40
15
15
20
25
30
30
40
45
40
45
45
60
60
70
80
80
40
45
40
45
50
60
70
80
90
90
20
20
20
25
25
30
35
40
45
45
15
15
20
25
30
30
35
35
50
50
50
50
50
60
60
70
80
80
90
90
50
50
50
50
50
60
70
80
90
90
100
100
25
25
25
25
25
30
35
40
45
45
50
50
15
20
20
25
30
30
35
35
40
40

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

142

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH078-150 Standard Motor - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.0

5.5

10.0

230

9.3

68

14.5

1.5

6.0

5.5

10.0

460

4.9

34

7.7

0.8

3.0

2.2

5.0

575

3.8

28

6

0.6

2.4

1.8

4.0

208

11.9

88

18.5

3.5

6.0

5.5

10.0

230

11.9

88

18.5

3.5

6.0

5.5

10.0

460

5.2

44

8.1

1.6

3.0

2.2

5.0

575

4.8

36

7.5

1.3

2.4

1.8

4.0

208

12.2

88

19

3.5

6.8

5.5

10.0

230

12.2

88

19

3.5

6.8

5.5

10.0

460

5.8

44

9

1.6

3.4

2.2

5.0

575

4.4

36

5.5

1.3

2.7

1.8

4.0

078
(6.5)

090
(7.5)

102
(8.5)

Johnson Controls Unitary Products

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

40.1
43.6
66.8
82.5
108.5
40.1
47.1
74.1
92.2
122.2
20.7
23.5
37.1
46.1
61.1
16.2
18.8
29.7
36.9
48.9
49.8
49.8
66.8
82.5
108.5
49.8
49.8
74.1
92.2
122.2
22.9
23.5
37.1
46.1
61.1
19.8
19.8
29.7
36.9
48.9
51.3
51.3
67.8
83.5
109.5
51.3
51.3
75.1
93.2
123.2
24.7
24.7
37.6
46.6
61.6
19.2
19.2
30
37.2
49.3

45.6
50.5
73.7
89.3
115.4
45.6
53.9
81
99
129.1
22.9
26.3
39.8
48.8
63.9
18
21.1
31.9
39.1
51.1
55.3
55.3
73.7
89.3
115.4
55.3
55.3
81
99
129.1
25.1
26.3
39.8
48.8
63.9
21.6
21.6
31.9
39.1
51.1
56.8
56.8
74.7
90.3
116.4
56.8
56.8
82
100
130.1
26.9
26.9
40.3
49.3
64.4
21
21.5
32.3
39.5
51.5

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
50
50
50
60
70
80
90
90
110
125
50
50
50
60
80
90
100
100
125
150
25
25
25
30
40
40
50
50
70
70
20
20
20
25
30
35
40
40
50
60
60
60
60
60
70
80
90
90
110
125
60
60
60
60
80
90
100
100
125
150
25
30
25
30
40
40
50
50
70
70
20
25
20
25
30
35
40
40
50
60
60
60
60
60
70
80
90
100
110
125
60
60
60
60
80
90
100
100
125
150
30
30
30
30
40
45
50
50
70
70
20
25
20
25
30
35
40
40
50
60

143

528150-YTG-T-0514
ZH078-150 Standard Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

3.5

6.8

5.5

10.0

230

16.0 110.0 24.9

3.5

6.8

5.5

10.0

460

7.8

52.0

12.1

1.6

3.4

2.2

5.0

575

5.7

38.9

8.9

1.3

2.7

1.8

4.0

208

23.1

160

36

1.5

9.6

5.5

10.0

230

23.1

160

36

1.5

9.6

5.5

10.0

460

12.2

87

19

0.8

4.8

2.2

5.0

575

8.7

62

13.5

0.6

3.9

1.8

4.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

59.8
67.8
83.5
109.5
161.9
59.8
75.1
93.2
123.2
150.9
29.2
37.6
46.6
61.6
75.5
22.1
30.0
37.2
49.3
60.3
77.6
77.6
87
113
165.4
77.6
78.6
96.7
126.7
154.4
40.5
40.5
48.3
63.4
77.2
29.9
31.5
38.7
50.8
61.8

65.3
74.7
90.3
116.4
168.7
65.3
82.0
100.0
130.1
157.8
31.4
40.3
49.3
64.4
78.2
23.9
32.3
39.5
51.5
62.6
83.1
83.1
93.8
119.9
172.2
83.1
85.5
103.5
133.6
161.3
42.7
42.7
51.1
66.1
80
31.7
33.8
41
53
64.1

1

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
70
80
70
80
90
100
110
125
175
175
70
80
80
90
100
100
125
150
175
175
35
35
40
45
50
50
70
70
80
90
25
25
30
35
40
40
50
60
70
70
100
100
100
100
100
100
125
125
175
175
100
100
100
100
100
110
150
150
175
175
50
50
50
50
50
60
70
70
90
90
35
40
35
40
40
45
60
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

144

Johnson Controls Unitary Products

528150-YTG-T-0514

ZH037-061 Hi Static Indoor Blower - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.1

68

14.2

1.5

6.0

5.5

10.0

230

9.1

68

14.2

1.5

6.0

5.5

10.0

460

4.5

34

7

0.8

3.0

2.2

5.0

575

3.8

28

6

0.6

2.4

1.8

4.0

208

11.2

88

17.5

1.5

6.0

5.5

10.0

230

11.2

88

17.5

1.5

6.0

5.5

10.0

460

5.6

44

8.0

0.8

3.0

2.2

5.0

575

4.5

36

7.0

0.6

2.4

1.8

4.0

208

14.1

88

22

1.5

6.8

5.5

10.0

230

14.1

88

22

1.5

6.8

5.5

10.0

460

7.7

55

12

0.8

3.4

2.2

5.0

575

5.1

36

7.5

0.6

2.7

1.8

4.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

29.1
29.1
35.6
43.6
59.2
29.1
29.1
38
47.1
65.1
14.6
14.6
19
23.5
32.6
11.8
18.8
26
31.5
35.6
43.6
59.2
72
31.5
38
47.1
65.1
80.1
15.8
19
23.5
32.6
40.1
12.6
18.8
26
32.1
37.4
37.4
44.6
60.2
73
83.5
37.4
39
48.1
66.1
81.1
93.2
19.6
19.6
24
33.1
40.6
46.6
14.3
19.2
26.4
32.4
37.2

34.6
34.9
42.5
50.5
66.1
34.6
35.9
44.9
53.9
72
16.8
17.3
21.8
26.3
35.3
13.6
21.1
28.3
37
42.5
50.5
66.1
78.9
37
44.9
53.9
72
87
18
21.8
26.3
35.3
42.8
14.4
21.1
28.3
34.3
42.9
43.5
51.5
67.1
79.9
90.3
42.9
45.9
54.9
73
88
100
21.8
22.3
26.8
35.8
43.3
49.3
16.1
21.5
28.7
34.7
39.5

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3.0
6.0
9.0
15.0
3.0
6.0
9.0
15.0
9.0
15.0
4.5
6.8
11.3
15.0
6.0
9.0
15.0
20.0
6.0
9.0
15.0
20.0
9.0
15.0
20.0
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
40
35
40
40
45
45
60
60
70
35
40
35
40
40
45
50
60
70
80
15
20
15
20
20
25
25
30
35
40
15
15
20
25
30
30
40
45
40
45
45
60
60
70
80
80
40
45
40
45
50
60
70
80
90
90
20
20
20
25
25
30
35
40
45
45
15
15
20
25
30
30
35
35
50
50
50
50
50
60
70
70
80
80
90
100
50
50
50
50
50
60
70
80
90
90
100
100
25
25
25
25
25
30
35
40
45
45
50
50
15
20
20
25
30
30
35
35
40
40

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

145

528150-YTG-T-0514

ZH078-150 Hi Static Motor - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.8

5.5

10.0

230

9.3

68

14.5

1.5

6.8

5.5

10.0

460

4.9

34

7.7

0.8

3.4

2.2

5.0

575

3.8

28

6

0.6

2.7

1.8

4.0

208

11.9

88

18.5

3.5

9.6

5.5

10.0

230

11.9

88

18.5

3.5

9.6

5.5

10.0

460

5.2

44

8.1

1.6

4.8

2.2

5.0

575

4.8

36

7.5

1.3

3.9

1.8

4.0

208

12.2

88

19

3.5

9.6

5.5

10.0

230

12.2

88

19

3.5

9.6

5.5

10.0

460

5.8

44

9

1.6

4.8

2.2

5.0

575

4.4

36

5.5

1.3

3.9

1.8

4.0

078
(6.5)

090
(7.5)

102
(8.5)

146

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

40.9
44.6
67.8
83.5
109.5
40.9
48.1
75.1
93.2
123.2
21.1
24
37.6
46.6
61.6
16.5
19.2
30
37.2
49.3
53.4
53.4
71.3
87
113
53.4
53.4
78.6
96.7
126.7
24.7
25.8
39.3
48.3
63.4
21.3
21.3
31.5
38.7
50.8
54.1
54.1
71.3
87
113
54.1
54.1
78.6
96.7
126.7
26.1
26.1
39.3
48.3
63.4
20.4
20.7
31.5
38.7
50.8

46.4
51.5
74.7
90.3
116.4
46.4
54.9
82
100
130.1
23.3
26.8
40.3
49.3
64.4
18.3
21.5
32.3
39.5
51.5
58.9
58.9
78.2
93.8
119.9
58.9
58.9
85.5
103.5
133.6
26.9
28.5
42.1
51.1
66.1
23.1
23.1
33.8
41
53
59.6
59.6
78.2
93.8
119.9
59.6
59.6
85.5
103.5
133.6
28.3
28.5
42.1
51.1
66.1
22.2
23
33.8
41
53

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
50
50
50
60
70
80
90
100
110
125
50
50
50
60
80
90
100
100
125
150
25
25
25
30
40
45
50
50
70
70
20
20
20
25
30
35
40
40
50
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
80
90
100
110
150
150
25
30
30
30
40
45
50
60
70
70
25
25
25
25
35
35
40
45
60
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
80
90
100
110
150
150
30
30
30
30
40
45
50
60
70
70
25
25
25
25
35
35
40
45
60
60

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH078-150 Hi Static Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

3.5

9.6

5.5

10.0

230

16.0 110.0 24.9

3.5

9.6

5.5

10.0

460

7.8

52.0

12.1

1.6

4.8

2.2

5.0

575

5.7

38.9

8.9

1.3

3.9

1.8

4.0

208

23.1

160

36

1.5

15.2

5.5

10.0

230

23.1

160

36

1.5

15.2

5.5

10.0

460

12.2

87

19

0.8

7.6

2.2

5.0

575

8.7

62

13.5

0.6

6.1

1.8

4.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

62.6
71.3
87.0
113.0
165.4
62.6
78.6
96.7
126.7
154.4
30.6
39.3
48.3
63.4
77.2
23.3
31.5
38.7
50.8
61.8
83.2
83.2
94
120
172.4
83.2
85.6
103.7
133.7
161.4
43.3
43.3
51.8
66.9
80.7
32.1
34.3
41.5
53.5
64.6

68.1
78.2
93.8
119.9
172.2
68.1
85.5
103.5
133.6
161.3
32.8
42.1
51.1
66.1
80.0
25.1
33.8
41.0
53.0
64.1
88.7
88.7
100.8
126.9
179.2
88.7
92.5
110.5
140.6
168.3
45.5
45.6
54.6
69.6
83.5
33.9
36.5
43.7
55.8
66.8

1

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
70
80
80
80
90
100
125
125
175
175
70
80
80
90
100
110
150
150
175
175
35
40
40
45
50
60
70
70
90
90
25
30
35
35
40
45
60
60
70
70
100
110
100
110
100
110
125
150
175
200
100
110
100
110
110
125
150
150
175
175
50
50
50
50
60
60
70
70
90
90
40
40
40
40
45
45
60
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

147

528150-YTG-T-0514

ZJ037-061 Standard Indoor Blower - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

0.0

230

8.7

68

13.5

1.5

6.0

5.5

0.0

460

4.6

34

7.1

0.8

3.0

2.2

0.0

575

3.5

28

5.5

0.6

2.4

1.8

0.0

208

11.2

88

17.5

1.5

6.0

5.5

0.0

230

11.2

88

17.5

1.5

6.0

5.5

0.0

460

5.6

44

8.0

0.8

3.0

2.2

0.0

575

4.5

36

7.0

0.6

2.4

1.8

0.0

208

14.1

88

22

1.5

6.0

5.5

0.0

230

14.1

88

22

1.5

6.0

5.5

0.0

460

7.7

55

12

0.8

3.0

2.2

0.0

575

5.1

36

7.5

0.6

2.4

1.8

0.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

18.4
18.4
23.1
31.1
46.7
18.4
18.4
25.5
34.6
52.6
9.6
9.6
12.8
17.3
26.3
7.4
13.8
21
21.5
23.1
31.1
46.7
59.5
21.7
25.5
34.6
52.6
67.6
10.8
12.8
17.3
26.3
33.8
8.6
13.8
21
27.1
26.6
26.6
31.1
46.7
59.5
70
26.6
26.6
34.6
52.6
67.6
79.7
14.2
14.2
17.3
26.3
33.8
39.8
10
13.8
21
27.1
31.9

23.9
23.9
30
38
53.6
23.9
23.9
32.4
41.4
59.5
11.8
11.8
15.5
20
29.1
9.2
16.1
23.3
27
30
38
53.6
66.4
27
32.4
41.4
59.5
74.5
13
15.5
20
29.1
36.6
10.4
16.1
23.3
29.3
32.1
32.1
38
53.6
66.4
76.8
32.1
32.4
41.4
59.5
74.5
86.5
16.4
16.4
20
29.1
36.6
42.6
11.8
16.1
23.3
29.3
34.1

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
25
30
25
30
25
30
35
40
50
60
25
30
25
30
30
35
35
45
60
60
15
15
15
15
15
20
20
20
30
30
15
15
15
20
25
25
30
35
30
35
35
40
50
60
60
70
30
35
30
35
35
45
60
60
70
80
15
15
15
20
20
20
30
30
35
40
15
15
15
20
25
25
30
30
35
45
35
45
40
45
50
60
60
70
70
80
35
45
35
45
40
45
60
60
70
80
80
90
20
20
20
20
20
20
30
30
35
40
40
45
15
15
15
20
25
25
30
30
35
35

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

148

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ078-150 Standard Motor - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.0

5.5

0.0

230

9.3

68

14.5

1.5

6.0

5.5

0.0

460

4.9

34

7.6

0.8

3.0

2.2

0.0

575

3.8

28

6

0.6

2.4

1.8

0.0

208

11.9

88

18.5

3.5

6.0

5.5

0.0

230

11.9

88

18.5

3.5

6.0

5.5

0.0

460

5.2

44

8.1

1.6

3.0

2.2

0.0

575

4.8

36

7.5

1.3

2.4

1.8

0.0

208

12.2

88

19

3.5

6.8

5.5

0.0

230

12.2

88

19

3.5

6.8

5.5

0.0

460

5.8

44

9

1.6

3.4

2.2

0.0

575

4.4

36

5.5

1.3

2.7

1.8

0.0

078
(6.5)

090
(7.5)

102
(8.5)

Johnson Controls Unitary Products

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

29.9
31.1
54.3
70
96
29.9
34.6
61.6
79.7
109.7
15.6
17.3
30.8
39.8
54.9
12.2
13.8
24.7
31.9
43.9
39.8
39.8
54.3
70
96
39.8
39.8
61.6
79.7
109.7
17.9
17.9
30.8
39.8
54.9
15.8
15.8
24.7
31.9
43.9
41.3
41.3
55.3
71
97
41.3
41.3
62.6
80.7
110.7
19.7
19.7
31.3
40.3
55.4
15.2
15.2
25
32.2
44.3

35.4
38
61.2
76.8
102.9
35.4
41.4
68.5
86.5
116.6
17.8
20
33.6
42.6
57.6
14
16.1
26.9
34.1
46.1
45.3
45.3
61.2
76.8
102.9
45.3
45.3
68.5
86.5
116.6
20.1
20.1
33.6
42.6
57.6
17.6
17.6
26.9
34.1
46.1
46.8
46.8
62.2
77.8
103.9
46.8
46.8
69.5
87.5
117.6
21.9
21.9
34.1
43.1
58.1
17
17
27.3
34.5
46.5

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
35
40
35
40
60
70
70
80
100
110
35
40
35
45
70
70
80
90
110
125
20
20
20
20
35
35
40
45
60
60
15
15
15
20
25
30
35
35
45
50
50
50
50
50
60
70
70
80
100
110
50
50
50
50
70
70
80
90
110
125
20
25
20
25
35
35
40
45
60
60
20
20
20
20
25
30
35
35
45
50
50
50
50
50
60
70
80
80
100
110
50
50
50
50
70
70
90
90
125
125
25
25
25
25
35
35
45
45
60
60
20
20
20
20
25
30
35
35
45
50

149

528150-YTG-T-0514
ZJ078-150 Standard Motor - Without Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16

110

24.9

3.5

6.8

5.5

0.0

230

16

110

24.9

3.5

6.8

5.5

0.0

460

7.8

52

12.1

1.6

3.4

2.2

0.0

575

5.7

38.9

8.9

1.3

2.7

1.8

0.0

208

23.1

160

36

1.5

9.6

5.5

0.0

230

23.1

160

36

1.5

9.6

5.5

0.0

460

12.2

87

19

0.8

4.8

2.2

0.0

575

8.7

62

13.5

0.6

3.9

1.8

0.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

49.8
55.3
71
97
149.4
49.8
62.6
80.7
110.7
138.4
24.2
31.3
40.3
55.4
69.2
18.1
25
32.2
44.3
55.3
67.6
67.6
74.5
100.5
152.9
67.6
67.6
84.2
114.2
141.9
35.5
35.5
42.1
57.1
71
25.9
26.5
33.7
45.8
56.8

55.3
62.2
77.8
103.9
156.2
55.3
69.5
87.5
117.6
145.3
26.4
34.1
43.1
58.1
72
19.9
27.3
34.5
46.5
57.6
73.1
73.1
81.3
107.4
159.7
73.1
73.1
91
121.1
148.8
37.7
37.7
44.8
59.9
73.7
27.7
28.8
36
48
59.1

1

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
60
70
60
70
80
80
100
110
150
175
60
70
70
70
90
90
125
125
150
175
30
30
35
35
45
45
60
60
80
80
20
25
25
30
35
35
45
50
60
60
90
90
90
90
90
90
110
110
175
175
90
90
90
90
90
100
125
125
175
175
45
45
45
45
45
45
60
60
80
80
30
35
30
35
35
40
50
50
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

150

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

0.0

230

8.7

68

13.5

1.5

6.0

5.5

0.0

460

4.6

34

7.1

0.8

3.0

2.2

0.0

575

3.5

28

5.5

0.6

2.4

1.8

0.0

208

11.2

88

17.5

1.5

6.0

5.5

0.0

230

11.2

88

17.5

1.5

6.0

5.5

0.0

460

5.6

44

8.0

0.8

3.0

2.2

0.0

575

4.5

36

7.0

0.6

2.4

1.8

0.0

208

14.1

88

22

1.5

6.8

5.5

0.0

230

14.1

88

22

1.5

6.8

5.5

0.0

460

7.7

55

12

0.8

3.4

2.2

0.0

575

5.1

36

7.5

0.6

2.7

1.8

0.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

18.4
18.4
23.1
31.1
46.7
18.4
18.4
25.5
34.6
52.6
9.6
9.6
12.8
17.3
26.3
7.4
13.8
21
21.5
23.1
31.1
46.7
59.5
21.5
25.5
34.6
52.6
67.6
10.8
12.8
17.3
26.3
33.8
8.6
13.8
21
27.1
27.4
27.4
32.1
47.7
60.5
71
27.4
27.4
35.6
53.6
68.6
80.7
14.6
14.6
17.8
26.8
34.3
40.3
10.3
14.2
21.4
27.4
32.2

23.9
23.9
30
38
53.6
23.9
23.9
32.4
41.4
59.5
11.8
11.8
15.5
20
29.1
9.2
16.1
23.3
27
30
38
53.6
66.4
27
32.4
41.4
59.5
74.5
13
15.5
20
29.1
36.6
10.4
16.1
23.3
29.3
32.9
32.9
39
54.6
67.4
77.8
32.9
33.4
42.4
60.5
75.5
87.5
16.8
16.8
20.5
29.6
37.1
43.1
12.1
16.5
23.7
29.7
34.5

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
25
30
25
30
25
30
35
40
50
60
25
30
25
30
30
35
35
45
60
60
15
15
15
15
15
20
20
20
30
30
15
15
15
20
25
25
30
35
30
35
35
40
50
60
60
70
30
35
30
35
35
45
60
60
70
80
15
15
15
20
20
20
30
30
35
40
15
15
15
20
25
25
30
30
35
45
35
45
40
45
50
60
70
70
80
80
35
45
35
45
40
45
60
70
70
80
90
90
20
20
20
20
20
25
30
30
35
40
45
45
15
15
15
20
25
25
30
30
35
35

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

151

528150-YTG-T-0514

ZJ078-150 Hi Static Motor - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.8

5.5

0.0

230

9.3

68

14.5

1.5

6.8

5.5

0.0

460

4.9

34

7.6

0.8

3.4

2.2

0.0

575

3.8

28

6

0.6

2.7

1.8

0.0

208

11.9

88

18.5

3.5

9.6

5.5

0.0

230

11.9

88

18.5

3.5

9.6

5.5

0.0

460

5.2

44

8.1

1.6

4.8

2.2

0.0

575

4.8

36

7.5

1.3

3.9

1.8

0.0

208

12.2

88

19

3.5

9.6

5.5

0.0

230

12.2

88

19

3.5

9.6

5.5

0.0

460

5.8

44

9

1.6

4.8

2.2

0.0

575

4.4

36

5.5

1.3

3.9

1.8

0.0

078
(6.5)

090
(7.5)

102
(8.5)

152

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

30.7
32.1
55.3
71
97
30.7
35.6
62.6
80.7
110.7
16
17.8
31.3
40.3
55.4
12.5
14.2
25
32.2
44.3
43.4
43.4
58.8
74.5
100.5
43.4
43.4
66.1
84.2
114.2
19.7
19.7
33.1
42.1
57.1
17.3
17.3
26.5
33.7
45.8
44.1
44.1
58.8
74.5
100.5
44.1
44.1
66.1
84.2
114.2
21.1
21.1
33.1
42.1
57.1
16.4
16.4
26.5
33.7
45.8

36.2
39
62.2
77.8
103.9
36.2
42.4
69.5
87.5
117.6
18.2
20.5
34.1
43.1
58.1
14.3
16.5
27.3
34.5
46.5
48.9
48.9
65.7
81.3
107.4
48.9
48.9
73
91
121.1
21.9
22.3
35.8
44.8
59.9
19.1
19.1
28.8
36
48
49.6
49.6
65.7
81.3
107.4
49.6
49.6
73
91
121.1
23.3
23.3
35.8
44.8
59.9
18.2
18.2
28.8
36
48

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
40
45
40
45
60
70
80
80
100
110
40
45
40
45
70
70
90
90
125
125
20
20
20
25
35
35
45
45
60
60
15
15
15
20
25
30
35
35
45
50
50
60
50
60
60
70
80
90
110
110
50
60
50
60
70
80
90
100
125
125
20
25
20
25
35
40
45
45
60
60
20
20
20
20
30
30
35
40
50
50
50
60
50
60
60
70
80
90
110
110
50
60
50
60
70
80
90
100
125
125
25
25
25
25
35
40
45
45
60
60
20
20
20
20
30
30
35
40
50
50

Johnson Controls Unitary Products

528150-YTG-T-0514
ZJ078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16

110

24.9

3.5

9.6

5.5

0.0

230

16

110

24.9

3.5

9.6

5.5

0.0

460

7.8

52

12.1

1.6

4.8

2.2

0.0

575

5.7

38.9

8.9

1.3

3.9

1.8

0.0

208

23.1

160

36

1.5

15.2

5.5

0.0

230

23.1

160

36

1.5

15.2

5.5

0.0

460

12.2

87

19

0.8

7.6

2.2

0.0

575

8.7

62

13.5

0.6

6.1

1.8

0.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

52.6
58.8
74.5
100.5
152.9
52.6
66.1
84.2
114.2
141.9
25.6
33.1
42.1
57.1
71
19.3
26.5
33.7
45.8
56.8
73.2
73.2
81.5
107.5
159.9
73.2
73.2
91.2
121.2
148.9
38.3
38.3
45.6
60.6
74.5
28.1
29.3
36.5
48.5
59.6

58.1
65.7
81.3
107.4
159.7
58.1
73
91
121.1
148.8
27.8
35.8
44.8
59.9
73.7
21.1
28.8
36
48
59.1
78.7
78.7
88.3
114.4
166.7
78.7
80
98
128.1
155.8
40.5
40.5
48.3
63.4
77.2
29.9
31.5
38.7
50.8
61.8

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
60
70
60
70
80
90
110
110
175
175
60
70
70
80
90
100
125
125
175
175
30
35
35
40
45
45
60
60
80
80
25
25
30
30
35
40
50
50
70
70
90
100
90
100
90
100
110
125
175
175
90
100
90
100
100
100
125
150
175
175
50
50
50
50
50
50
70
70
90
90
35
35
35
35
40
40
50
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

153

528150-YTG-T-0514

ZJ037-061 Standard Indoor Blower - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

10.0

230

8.7

68

13.5

1.5

6.0

5.5

10.0

460

4.6

34

7.1

0.8

3.0

2.2

5.0

575

3.5

28

5.5

0.6

2.4

1.8

4.0

208

11.2

88

17.5

1.5

6.0

5.5

10.0

230

11.2

88

17.5

1.5

6.0

5.5

10.0

460

5.6

44

8.0

0.8

3.0

2.2

5.0

575

4.5

36

7.0

0.6

2.4

1.8

4.0

208

14.1

88

22

1.5

6.0

5.5

10.0

230

14.1

88

22

1.5

6.0

5.5

10.0

460

7.7

55

12

0.8

3.0

2.2

5.0

575

5.1

36

7.5

0.6

2.4

1.8

4.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

28.7
28.7
35.6
43.6
59.2
28.7
29
38
47.1
65.1
14.7
14.7
19
23.5
32.6
11.5
18.8
26
31.5
35.6
43.6
59.2
72
31.5
38
47.1
65.1
80.1
15.8
19
23.5
32.6
40.1
12.6
18.8
26
32.1
36.6
36.6
43.6
59.2
72
82.5
36.6
38
47.1
65.1
80.1
92.2
19.2
19.2
23.5
32.6
40.1
46.1
14
18.8
26
32.1
36.9

34.2
34.9
42.5
50.5
66.1
34.2
35.9
44.9
53.9
72
16.9
17.3
21.8
26.3
35.3
13.3
21.1
28.3
37
42.5
50.5
66.1
78.9
37
44.9
53.9
72
87
18
21.8
26.3
35.3
42.8
14.4
21.1
28.3
34.3
42.1
42.5
50.5
66.1
78.9
89.3
42.1
44.9
53.9
72
87
99
21.4
21.8
26.3
35.3
42.8
48.8
15.8
21.1
28.3
34.3
39.1

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15.0
6.0
9.0
15.0
20.0
6.0
9.0
15.0
20.0
9.0
15.0
20.0
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
40
35
40
40
45
45
60
60
70
35
40
35
40
40
45
50
60
70
80
15
20
15
20
20
25
25
30
35
40
15
15
20
25
30
30
40
45
40
45
45
60
60
70
80
80
40
45
40
45
50
60
70
80
90
90
20
20
20
25
25
30
35
40
45
45
15
15
20
25
30
30
35
35
50
50
50
50
50
60
60
70
80
80
90
90
50
50
50
50
50
60
70
80
90
90
100
100
25
25
25
25
25
30
35
40
45
45
50
50
15
20
20
25
30
30
35
35
40
40

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

154

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ078-150 Standard Motor - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.0

5.5

10.0

230

9.3

68

14.5

1.5

6.0

5.5

10.0

460

4.9

34

7.6

0.8

3.0

2.2

5.0

575

3.8

28

6

0.6

2.4

1.8

4.0

208

11.9

88

18.5

3.5

6.0

5.5

10.0

230

11.9

88

18.5

3.5

6.0

5.5

10.0

460

5.2

44

8.1

1.6

3.0

2.2

5.0

575

4.8

36

7.5

1.3

2.4

1.8

4.0

208

12.2

88

19

3.5

6.8

5.5

10.0

230

12.2

88

19

3.5

6.8

5.5

10.0

460

5.8

44

9

1.6

3.4

2.2

5.0

575

4.4

36

5.5

1.3

2.7

1.8

4.0

078
(6.5)

090
(7.5)

102
(8.5)

Johnson Controls Unitary Products

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

40.1
43.6
66.8
82.5
108.5
40.1
47.1
74.1
92.2
122.2
20.7
23.5
37.1
46.1
61.1
16.2
18.8
29.7
36.9
48.9
49.8
49.8
66.8
82.5
108.5
49.8
49.8
74.1
92.2
122.2
22.9
23.5
37.1
46.1
61.1
19.8
19.8
29.7
36.9
48.9
51.3
51.3
67.8
83.5
109.5
51.3
51.3
75.1
93.2
123.2
24.7
24.7
37.6
46.6
61.6
19.2
19.2
30
37.2
49.3

45.6
50.5
73.7
89.3
115.4
45.6
53.9
81
99
129.1
22.9
26.3
39.8
48.8
63.9
18
21.1
31.9
39.1
51.1
55.3
55.3
73.7
89.3
115.4
55.3
55.3
81
99
129.1
25.1
26.3
39.8
48.8
63.9
21.6
21.6
31.9
39.1
51.1
56.8
56.8
74.7
90.3
116.4
56.8
56.8
82
100
130.1
26.9
26.9
40.3
49.3
64.4
21
21.5
32.3
39.5
51.5

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
50
50
50
60
70
80
90
90
110
125
50
50
50
60
80
90
100
100
125
150
25
25
25
30
40
40
50
50
70
70
20
20
20
25
30
35
40
40
50
60
60
60
60
60
70
80
90
90
110
125
60
60
60
60
80
90
100
100
125
150
25
30
25
30
40
40
50
50
70
70
20
25
20
25
30
35
40
40
50
60
60
60
60
60
70
80
90
100
110
125
60
60
60
60
80
90
100
100
125
150
30
30
30
30
40
45
50
50
70
70
20
25
20
25
30
35
40
40
50
60

155

528150-YTG-T-0514
ZJ078-150 Standard Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16

110

24.9

3.5

6.8

5.5

10.0

230

16

110

24.9

3.5

6.8

5.5

10.0

460

7.8

52

12.1

1.6

3.4

2.2

5.0

575

5.7

38.9

8.9

1.3

2.7

1.8

4.0

208

23.1

160

36

1.5

9.6

5.5

10.0

230

23.1

160

36

1.5

9.6

5.5

10.0

460

12.2

87

19

0.8

4.8

2.2

5.0

575

8.7

62

13.5

0.6

3.9

1.8

4.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

59.8
67.8
83.5
109.5
161.9
59.8
75.1
93.2
123.2
150.9
29.2
37.6
46.6
61.6
75.5
22.1
30
37.2
49.3
60.3
77.6
77.6
87
113
165.4
77.6
78.6
96.7
126.7
154.4
40.5
40.5
48.3
63.4
77.2
29.9
31.5
38.7
50.8
61.8

65.3
74.7
90.3
116.4
168.7
65.3
82
100
130.1
157.8
31.4
40.3
49.3
64.4
78.2
23.9
32.3
39.5
51.5
62.6
83.1
83.1
93.8
119.9
172.2
83.1
85.5
103.5
133.6
161.3
42.7
42.7
51.1
66.1
80
31.7
33.8
41
53
64.1

1

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
70
80
70
80
90
100
110
125
175
175
70
80
80
90
100
100
125
150
175
175
35
35
40
45
50
50
70
70
80
90
25
25
30
35
40
40
50
60
70
70
100
100
100
100
100
100
125
125
175
175
100
100
100
100
100
110
150
150
175
175
50
50
50
50
50
60
70
70
90
90
35
40
35
40
40
45
60
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

156

Johnson Controls Unitary Products

528150-YTG-T-0514

ZJ037-061 Hi Static Blower - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

10.0

230

8.7

68

13.5

1.5

6.0

5.5

10.0

460

4.6

34

7.1

0.8

3.0

2.2

5.0

575

3.5

28

5.5

0.6

2.4

1.8

4.0

208

11.2

88

17.5

1.5

6.0

5.5

10.0

230

11.2

88

17.5

1.5

6.0

5.5

10.0

460

5.6

44

8.0

0.8

3.0

2.2

5.0

575

4.5

36

7.0

0.6

2.4

1.8

4.0

208

14.1

88

22

1.5

6.8

5.5

10.0

230

14.1

88

22

1.5

6.8

5.5

10.0

460

7.7

55

12

0.8

3.4

2.2

5.0

575

5.1

36

7.5

0.6

2.7

1.8

4.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

28.7
28.7
35.6
43.6
59.2
28.7
29
38
47.1
65.1
14.7
14.7
19
23.5
32.6
11.5
18.8
26
31.5
35.6
43.6
59.2
72
31.5
38
47.1
65.1
80.1
15.8
19
23.5
32.6
40.1
12.6
18.8
26
32.1
37.4
37.4
44.6
60.2
73
83.5
37.4
39
48.1
66.1
81.1
93.2
19.6
19.6
24
33.1
40.6
46.6
14.3
19.2
26.4
32.4
37.2

34.2
34.9
42.5
50.5
66.1
34.2
35.9
44.9
53.9
72
16.9
17.3
21.8
26.3
35.3
13.3
21.1
28.3
37
42.5
50.5
66.1
78.9
37
44.9
53.9
72
87
18
21.8
26.3
35.3
42.8
14.4
21.1
28.3
34.3
42.9
43.5
51.5
67.1
79.9
90.3
42.9
45.9
54.9
73
88
100
21.8
22.3
26.8
35.8
43.3
49.3
16.1
21.5
28.7
34.7
39.5

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15.0
6.0
9.0
15.0
20.0
6.0
9.0
15.0
20.0
9.0
15.0
20.0
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
40
35
40
40
45
45
60
60
70
35
40
35
40
40
45
50
60
70
80
15
20
15
20
20
25
25
30
35
40
15
15
20
25
30
30
40
45
40
45
45
60
60
70
80
80
40
45
40
45
50
60
70
80
90
90
20
20
20
25
25
30
35
40
45
45
15
15
20
25
30
30
35
35
50
50
50
50
50
60
70
70
80
80
90
100
50
50
50
50
50
60
70
80
90
90
100
100
25
25
25
25
25
30
35
40
45
45
50
50
15
20
20
25
30
30
35
35
40
40

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

157

528150-YTG-T-0514

ZJ078-150 Hi Static Motor - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

9.3

68

14.5

1.5

6.8

5.5

10.0

230

9.3

68

14.5

1.5

6.8

5.5

10.0

460

4.9

34

7.6

0.8

3.4

2.2

5.0

575

3.8

28

6

0.6

2.7

1.8

4.0

208

11.9

88

18.5

3.5

9.6

5.5

10.0

230

11.9

88

18.5

3.5

9.6

5.5

10.0

460

5.2

44

8.1

1.6

4.8

2.2

5.0

575

4.8

36

7.5

1.3

3.9

1.8

4.0

208

12.2

88

19

3.5

9.6

5.5

10.0

230

12.2

88

19

3.5

9.6

5.5

10.0

460

5.8

44

9

1.6

4.8

2.2

5.0

575

4.4

36

5.5

1.3

3.9

1.8

4.0

078
(6.5)

090
(7.5)

102
(8.5)

158

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34
6.8
13.5
18
25.5
9
18
24
34
9
18
24
34
9
18
24
34

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

40.9
44.6
67.8
83.5
109.5
40.9
48.1
75.1
93.2
123.2
21.1
24
37.6
46.6
61.6
16.5
19.2
30
37.2
49.3
53.4
53.4
71.3
87
113
53.4
53.4
78.6
96.7
126.7
24.7
25.8
39.3
48.3
63.4
21.3
21.3
31.5
38.7
50.8
54.1
54.1
71.3
87
113
54.1
54.1
78.6
96.7
126.7
26.1
26.1
39.3
48.3
63.4
20.4
20.7
31.5
38.7
50.8

46.4
51.5
74.7
90.3
116.4
46.4
54.9
82
100
130.1
23.3
26.8
40.3
49.3
64.4
18.3
21.5
32.3
39.5
51.5
58.9
58.9
78.2
93.8
119.9
58.9
58.9
85.5
103.5
133.6
26.9
28.5
42.1
51.1
66.1
23.1
23.1
33.8
41
53
59.6
59.6
78.2
93.8
119.9
59.6
59.6
85.5
103.5
133.6
28.3
28.5
42.1
51.1
66.1
22.2
23
33.8
41
53

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
50
50
50
60
70
80
90
100
110
125
50
50
50
60
80
90
100
100
125
150
25
25
25
30
40
45
50
50
70
70
20
20
20
25
30
35
40
40
50
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
80
90
100
110
150
150
25
30
30
30
40
45
50
60
70
70
25
25
25
25
35
35
40
45
60
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
80
90
100
110
150
150
30
30
30
30
40
45
50
60
70
70
25
25
25
25
35
35
40
45
60
60

Johnson Controls Unitary Products

528150-YTG-T-0514
ZJ078-150 Hi Static Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16

110

24.9

3.5

9.6

5.5

10.0

230

16

110

24.9

3.5

9.6

5.5

10.0

460

7.8

52

12.1

1.6

4.8

2.2

5.0

575

5.7

38.9

8.9

1.3

3.9

1.8

4.0

208

23.1

160

36

1.5

15.2

5.5

10.0

230

23.1

160

36

1.5

15.2

5.5

10.0

460

12.2

87

19

0.8

7.6

2.2

5.0

575

8.7

62

13.5

0.6

6.1

1.8

4.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54
13.5
18
25.5
40.6
18
24
34
54
18
24
34
54
18
24
34
54

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

62.6
71.3
87
113
165.4
62.6
78.6
96.7
126.7
154.4
30.6
39.3
48.3
63.4
77.2
23.3
31.5
38.7
50.8
61.8
83.2
83.2
94
120
172.4
83.2
85.6
103.7
133.7
161.4
43.3
43.3
51.8
66.9
80.7
32.1
34.3
41.5
53.5
64.6

68.1
78.2
93.8
119.9
172.2
68.1
85.5
103.5
133.6
161.3
32.8
42.1
51.1
66.1
80
25.1
33.8
41
53
64.1
88.7
88.7
100.8
126.9
179.2
88.7
92.5
110.5
140.6
168.3
45.5
45.6
54.6
69.6
83.5
33.9
36.5
43.7
55.8
66.8

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
70
80
80
80
90
100
125
125
175
175
70
80
80
90
100
110
150
150
175
175
35
40
40
45
50
60
70
70
90
90
25
30
35
35
40
45
60
60
70
70
100
110
100
110
100
110
125
150
175
200
100
110
100
110
110
125
150
150
175
175
50
50
50
50
60
60
70
70
90
90
40
40
40
40
45
45
60
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

159

528150-YTG-T-0514

ZR037-061 Standard Indoor Blower - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

0.0

230

8.7

68

13.5

1.5

6.0

5.5

0.0

460

4.6

34

7.1

0.8

3.0

2.2

0.0

575

3.5

28

5.5

0.6

2.4

1.8

0.0

208

11.9

88

18.5

1.5

6.0

5.5

0.0

230

11.9

88

18.5

1.5

6.0

5.5

0.0

460

5.2

44

8.1

0.8

3.0

2.2

0.0

575

4.8

36

7.5

0.6

2.4

1.8

0.0

208

14.1

88

22.0

1.5

4.3

5.5

0.0

230

14.1

88

22.0

1.5

4.3

5.5

0.0

460

7.7

55

12.0

0.8

2.1

2.2

0.0

575

5.1

36

7.5

0.6

2.0

1.8

0.0

037
(3)

049
(4)

061
(4)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

18.4
18.4
23.1
31.1
46.7
18.4
18.4
25.5
34.6
52.6
9.6
9.6
12.8
17.3
26.3
7.4
13.8
21.0
23.9
23.9
31.1
46.7
59.5
23.9
25.5
34.6
52.6
67.6
11.1
12.8
17.3
26.3
33.8
9.6
13.8
21.0
27.1
26.6
26.6
31.1
46.7
59.5
70.0
26.6
26.6
34.6
52.6
67.6
79.7
14.2
14.2
17.3
26.3
33.8
39.8
10.0
13.8
21.0
27.1
31.9

23.9
23.9
30.0
38.0
53.6
23.9
23.9
32.4
41.4
59.5
11.8
11.8
15.5
20.0
29.1
9.2
16.1
23.3
29.4
30.0
38.0
53.6
66.4
29.4
32.4
41.4
59.5
74.5
13.3
15.5
20.0
29.1
36.6
11.4
16.1
23.3
29.3
32.1
32.1
38.0
53.6
66.4
76.8
32.1
32.4
41.4
59.5
74.5
86.5
16.4
16.4
20.0
29.1
36.6
42.6
11.8
16.1
23.3
29.3
34.1

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
25
30
25
30
25
30
35
40
50
60
25
30
25
30
30
35
35
45
60
60
15
15
15
15
15
20
20
20
30
30
15
15
15
20
25
25
30
40
30
40
35
40
50
60
60
70
30
40
35
40
35
45
60
60
70
80
15
15
15
20
20
20
30
30
35
40
15
15
15
20
25
25
30
30
35
45
35
45
40
45
50
60
60
70
70
80
35
45
35
45
40
45
60
60
70
80
80
90
20
20
20
20
20
20
30
30
35
40
40
45
15
15
15
20
25
25
30
30
35
35

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

160

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR078-150 Standard Motor - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

13.5

88.0

21.1

1.5

6.2

5.5

0.0

230

13.5

88.0

21.1

1.5

6.2

5.5

0.0

460

6.0

44.0

9.3

0.8

3.1

2.2

0.0

575

4.9

34.0

7.7

0.6

2.4

1.8

0.0

208

13.1

83.1

20.5

1.5

6.2

5.5

0.0

230

13.1

83.1

20.5

1.5

6.2

5.5

0.0

460

6.1

41.0

9.5

0.8

3.1

2.2

0.0

575

4.4

33.0

6.8

0.6

2.4

1.8

0.0

208

14.5

98.0

22.6

1.5

8.2

5.5

0.0

230

14.5

98.0

22.6

1.5

8.2

5.5

0.0

460

6.3

55.0

9.9

0.8

4.1

2.2

0.0

575

6.0

41.0

9.4

0.6

3.6

1.8

0.0

078
(6.5)

090
(7.5)

102
(8.5)

Johnson Controls Unitary Products

Electric Heat Option
Model

kW

Stages

Amps

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0

1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

39.6
39.6
54.6
70.2
96.2
39.6
39.6
61.9
79.9
110.0
18.2
18.2
30.9
40.0
55.0
14.6
14.6
24.7
31.9
43.9
38.7
38.7
54.6
70.2
96.2
38.7
38.7
61.9
79.9
110.0
18.4
18.4
30.9
40.0
55.0
13.5
13.8
24.7
31.9
43.9
43.8
43.8
57.1
72.7
98.7
43.8
43.8
64.4
82.4
112.5
19.9
19.9
32.2
41.2
56.2
18.3
18.3
26.2
33.4
45.4

45.1
45.1
61.5
77.1
103.1
45.1
45.1
68.8
86.8
116.9
20.4
20.4
33.7
42.7
57.7
16.4
16.4
26.9
34.1
46.1
44.2
44.2
61.5
77.1
103.1
44.2
44.2
68.8
86.8
116.9
20.6
20.6
33.7
42.7
57.7
15.3
16.1
26.9
34.1
46.1
49.3
49.3
64.0
79.6
105.6
49.3
49.3
71.3
89.3
119.4
22.1
22.1
34.9
44.0
59.0
20.1
20.1
28.4
35.6
47.6

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
50
50
50
50
60
70
80
80
100
110
50
50
50
50
70
70
80
90
110
125
20
25
20
25
35
35
40
45
60
60
15
20
15
20
25
30
35
35
45
50
50
50
50
50
60
70
80
80
100
110
50
50
50
50
70
70
80
90
110
125
20
25
20
25
35
35
40
45
60
60
15
20
15
20
25
30
35
35
45
50
50
60
50
60
60
70
80
80
100
110
50
60
50
60
70
80
90
90
125
125
25
25
25
25
35
35
45
45
60
60
20
25
20
25
30
30
35
40
50
50

161

528150-YTG-T-0514
ZR078-150 Standard Motor - Without Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

1.5

8.2

5.5

0.0

230

16.0 110.0 24.9

1.5

8.2

5.5

0.0

460

7.8

52.0

12.1

0.8

4.1

2.2

0.0

575

5.7

38.9

8.9

0.6

3.6

1.8

0.0

208

22.4 149.0 35.0

1.5

10.9

5.5

0.0

230

22.4 149.0 35.0

1.5

10.9

5.5

0.0

460

10.6

75.0

16.5

0.8

5.3

2.2

0.0

575

7.7

54.0

12.0

0.6

4.1

1.8

0.0

120
(10)

150
(12.5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

47.2
57.1
72.7
98.7
151.1
47.2
64.4
82.4
112.5
140.2
23.3
32.2
41.2
56.2
70.1
17.6
26.2
33.4
45.4
56.5
67.3
67.3
76.1
102.1
154.5
67.3
67.8
85.8
115.9
143.5
32.4
33.7
42.7
57.7
71.6
23.8
26.8
34.0
46.0
57.1

52.7
64.0
79.6
105.6
158.0
52.7
71.3
89.3
119.4
147.0
25.5
34.9
44.0
59.0
72.8
19.4
28.4
35.6
47.6
58.7
72.8
72.8
83.0
109.0
161.4
72.8
74.6
92.7
122.7
150.4
34.6
36.4
45.5
60.5
74.3
25.6
29.0
36.2
48.3
59.3

1

Model

kW

Stages

Amps

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
60
60
60
70
80
80
100
110
175
175
60
60
70
80
90
90
125
125
150
175
30
30
35
35
45
45
60
60
80
80
20
25
30
30
35
40
50
50
70
70
80
90
80
90
80
90
110
110
175
175
80
90
80
90
90
100
125
125
175
175
40
45
40
45
45
50
60
70
80
80
30
30
30
30
35
40
50
50
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

162

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR037-061 Hi Static Indoor Blower - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

0.0

230

8.7

68

13.5

1.5

6.0

5.5

0.0

460

4.6

34

7.1

0.8

3.0

2.2

0.0

575

3.5

28

5.5

0.6

2.4

1.8

0.0

208

11.9

88

18.5

1.5

6.0

5.5

0.0

230

11.9

88

18.5

1.5

6.0

5.5

0.0

460

5.2

44

8.1

0.8

3.0

2.2

0.0

575

4.8

36

7.5

0.6

2.4

1.8

0.0

208

14.1

88

22.0

1.5

4.3

5.5

0.0

230

14.1

88

22.0

1.5

4.3

5.5

0.0

460

7.7

55

12.0

0.8

2.1

2.2

0.0

575

5.1

36

7.5

0.6

2.0

1.8

0.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

18.4
18.4
23.1
31.1
46.7
18.4
18.4
25.5
34.6
52.6
9.6
9.6
12.8
17.3
26.3
7.4
13.8
21.0
23.9
23.9
31.1
46.7
59.5
23.9
25.5
34.6
52.6
67.6
11.1
12.8
17.3
26.3
33.8
9.6
13.8
21.0
27.1
27.4
27.4
32.1
47.7
60.5
71.0
27.4
27.4
35.6
53.6
68.6
80.7
14.6
14.6
17.8
26.8
34.3
40.3
10.3
14.2
21.4
27.4
32.2

23.9
23.9
30.0
38.0
53.6
23.9
23.9
32.4
41.4
59.5
11.8
11.8
15.5
20.0
29.1
9.2
16.1
23.3
29.4
30.0
38.0
53.6
66.4
29.4
32.4
41.4
59.5
74.5
13.3
15.5
20.0
29.1
36.6
11.4
16.1
23.3
29.3
32.9
32.9
39.0
54.6
67.4
77.8
32.9
33.4
42.4
60.5
75.5
87.5
16.8
16.8
20.5
29.6
37.1
43.1
12.1
16.5
23.7
29.7
34.5

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
25
25
25
35
50
25
25
30
35
60
15
15
15
20
30
15
15
25
30
30
35
50
60
30
35
35
60
70
15
15
20
30
35
15
15
25
30
35
35
40
50
70
80
35
35
40
60
70
90
20
20
20
30
35
45
15
15
25
30
35

30
30
30
40
60
30
30
35
45
60
15
15
20
20
30
15
20
25
40
40
40
60
70
40
40
45
60
80
15
20
20
30
40
15
20
25
30
45
45
45
60
70
80
45
45
45
70
80
90
20
20
25
30
40
45
15
20
25
30
35

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

163

528150-YTG-T-0514

ZR078-150 Hi Static Motor - Without Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

13.5

88.0

21.1

1.5

8.2

5.5

0.0

230

13.5

88.0

21.1

1.5

8.2

5.5

0.0

460

6.0

44.0

9.3

0.8

4.1

2.2

0.0

575

4.9

34.0

7.7

0.6

3.6

1.8

0.0

208

13.1

83.1

20.5

1.5

10.9

5.5

0.0

230

13.1

83.1

20.5

1.5

10.9

5.5

0.0

460

6.1

41.0

9.5

0.8

5.3

2.2

0.0

575

4.4

33.0

6.8

0.6

4.1

1.8

0.0

208

14.5

98.0

22.6

1.5

10.9

5.5

0.0

230

14.5

98.0

22.6

1.5

10.9

5.5

0.0

460

6.3

55.0

9.9

0.8

5.3

2.2

0.0

575

6.0

41.0

9.4

0.6

4.1

1.8

0.0

078
(6.5)

090
(7.5)

102
(8.5)

164

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

41.6
41.6
57.1
72.7
98.7
41.6
41.6
64.4
82.4
112.5
19.2
19.2
32.2
41.2
56.2
15.8
15.8
26.2
33.4
45.4
43.4
43.4
60.5
76.1
102.1
43.4
43.4
67.8
85.8
115.9
20.6
20.6
33.7
42.7
57.7
15.2
16.0
26.8
34.0
46.0
46.5
46.5
60.5
76.1
102.1
46.5
46.5
67.8
85.8
115.9
21.1
21.1
33.7
42.7
57.7
18.8
18.8
26.8
34.0
46.0

47.1
47.1
64.0
79.6
105.6
47.1
47.1
71.3
89.3
119.4
21.4
21.4
34.9
44.0
59.0
17.6
17.6
28.4
35.6
47.6
48.9
48.9
67.3
83.0
109.0
48.9
48.9
74.6
92.7
122.7
22.8
22.9
36.4
45.5
60.5
17.0
18.2
29.0
36.2
48.3
52.0
52.0
67.3
83.0
109.0
52.0
52.0
74.6
92.7
122.7
23.3
23.3
36.4
45.5
60.5
20.6
20.6
29.0
36.2
48.3

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
50
60
50
60
60
70
80
80
100
110
50
60
50
60
70
80
90
90
125
125
25
25
25
25
35
35
45
45
60
60
20
20
20
20
30
30
35
40
50
50
50
60
50
60
70
70
80
90
110
110
50
60
50
60
70
80
90
100
125
125
25
25
25
25
35
40
45
50
60
70
20
20
20
20
30
30
35
40
50
50
60
60
60
60
70
70
80
90
110
110
60
60
60
60
70
80
90
100
125
125
25
25
25
25
35
40
45
50
60
70
20
25
20
25
30
30
35
40
50
50

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

1.5

10.9

5.5

0.0

230

16.0 110.0 24.9

1.5

10.9

5.5

0.0

460

7.8

52.0

12.1

0.8

5.3

2.2

0.0

575

5.7

38.9

8.9

0.6

4.1

1.8

0.0

208

22.4 149.0 35.0

1.5

16.1

5.5

0.0

230

22.4 149.0 35.0

1.5

16.1

5.5

0.0

460

10.6

75.0

16.5

0.8

8.1

2.2

0.0

575

7.7

54.0

12.0

0.6

6.0

1.8

0.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

49.9
60.5
76.1
102.1
154.5
49.9
67.8
85.8
115.9
143.5
24.5
33.7
42.7
57.7
71.6
18.1
26.8
34.0
46.0
57.1
72.5
72.5
82.6
108.6
161.0
72.5
74.3
92.3
122.4
150.0
35.2
37.2
46.2
61.2
75.1
25.7
29.2
36.4
48.4
59.5

55.4
67.3
83.0
109.0
161.4
55.4
74.6
92.7
122.7
150.4
26.7
36.4
45.5
60.5
74.3
19.9
29.0
36.2
48.3
59.3
78.0
78.0
89.5
115.5
167.9
78.0
81.1
99.2
129.2
156.9
37.4
39.9
49.0
64.0
77.8
27.5
31.4
38.6
50.6
61.7

1

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
60
70
70
70
80
90
110
110
175
175
60
70
70
80
90
100
125
125
175
175
30
30
35
40
45
50
60
70
80
80
20
25
30
30
35
40
50
50
70
70
90
100
90
100
90
100
110
125
175
175
90
100
90
100
100
100
125
150
175
175
45
45
45
45
50
50
70
70
90
90
30
35
30
35
40
40
50
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

165

528150-YTG-T-0514
ZR037-061 Standard Indoor Blower - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

10.0

230

8.7

68

13.5

1.5

6.0

5.5

10.0

460

4.6

34

7.1

0.8

3.0

2.2

5.0

575

3.5

28

5.5

0.6

2.4

1.8

4.0

208

11.9

88

18.5

1.5

6.0

5.5

10.0

230

11.9

88

18.5

1.5

6.0

5.5

10.0

460

5.2

44

8.1

0.8

3.0

2.2

5.0

575

4.8

36

7.5

0.6

2.4

1.8

4.0

208

14.1

88

22.0

1.5

4.3

5.5

10.0

230

14.1

88

22.0

1.5

4.3

5.5

10.0

460

7.7

55

12.0

0.8

2.1

2.2

5.0

575

5.1

36

7.5

0.6

2.0

1.8

4.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

28.7
28.7
35.6
43.6
59.2
28.7
29.0
38.0
47.1
65.1
14.7
14.7
19.0
23.5
32.6
11.5
18.8
26.0
33.9
35.6
43.6
59.2
72.0
33.9
38.0
47.1
65.1
80.1
16.1
19.0
23.5
32.6
40.1
13.6
18.8
26.0
32.1
36.6
36.6
43.6
59.2
72.0
82.5
36.6
38.0
47.1
65.1
80.1
92.2
19.2
19.2
23.5
32.6
40.1
46.1
14.0
18.8
26.0
32.1
36.9

34.2
34.9
42.5
50.5
66.1
34.2
35.9
44.9
53.9
72.0
16.9
17.3
21.8
26.3
35.3
13.3
21.1
28.3
39.4
42.5
50.5
66.1
78.9
39.4
44.9
53.9
72.0
87.0
18.3
21.8
26.3
35.3
42.8
15.4
21.1
28.3
34.3
42.1
42.5
50.5
66.1
78.9
89.3
42.1
44.9
53.9
72.0
87.0
99.0
21.4
21.8
26.3
35.3
42.8
48.8
15.8
21.1
28.3
34.3
39.1

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
40
35
40
40
45
45
60
60
70
35
40
35
40
40
45
50
60
70
80
15
20
15
20
20
25
25
30
35
40
15
15
20
25
30
30
45
50
45
50
45
60
60
70
80
80
45
50
45
50
50
60
70
80
90
90
20
20
20
25
25
30
35
40
45
45
15
20
20
25
30
30
35
35
50
50
50
50
50
60
60
70
80
80
90
90
50
50
50
50
50
60
70
80
90
90
100
100
25
25
25
25
25
30
35
40
45
45
50
50
15
20
20
25
30
30
35
35
40
40

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

166

Johnson Controls Unitary Products

528150-YTG-T-0514

ZR078-150 Standard Motor - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

13.5

88.0

21.1

1.5

6.2

5.5

10.0

230

13.5

88.0

21.1

1.5

6.2

5.5

10.0

460

6.0

44.0

9.3

0.8

3.1

2.2

5.0

575

4.9

34.0

7.7

0.6

2.4

1.8

4.0

208

13.1

83.1

20.5

1.5

6.2

5.5

10.0

230

13.1

83.1

20.5

1.5

6.2

5.5

10.0

460

6.1

41.0

9.5

0.8

3.1

2.2

5.0

575

4.4

33.0

6.8

0.6

2.4

1.8

4.0

208

14.5

98.0

22.6

1.5

8.2

5.5

10.0

230

14.5

98.0

22.6

1.5

8.2

5.5

10.0

460

6.3

55.0

9.9

0.8

4.1

2.2

5.0

575

6.0

41.0

9.4

0.6

3.6

1.8

4.0

078
(6.5)

090
(7.5)

102
(8.5)

Johnson Controls Unitary Products

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

49.6
49.6
67.1
82.7
108.7
49.6
49.6
74.4
92.4
122.5
23.2
23.7
37.2
46.2
61.2
18.6
18.8
29.7
36.9
48.9
48.7
48.7
67.1
82.7
108.7
48.7
48.7
74.4
92.4
122.5
23.4
23.7
37.2
46.2
61.2
17.5
18.8
29.7
36.9
48.9
53.8
53.8
69.6
85.2
111.2
53.8
53.8
76.9
94.9
125.0
24.9
24.9
38.4
47.5
62.5
22.3
22.3
31.2
38.4
50.4

55.1
55.1
74.0
89.6
115.6
55.1
55.1
81.3
99.3
129.4
25.4
26.4
39.9
49.0
64.0
20.4
21.1
31.9
39.1
51.1
54.2
54.2
74.0
89.6
115.6
54.2
54.2
81.3
99.3
129.4
25.6
26.4
39.9
49.0
64.0
19.3
21.1
31.9
39.1
51.1
59.3
59.3
76.5
92.1
118.1
59.3
59.3
83.8
101.8
131.9
27.1
27.7
41.2
50.2
65.2
24.1
24.1
33.4
40.6
52.6

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
60
60
60
60
70
80
90
90
110
125
60
60
60
60
80
90
100
100
125
150
25
30
25
30
40
40
50
50
70
70
20
25
20
25
30
35
40
40
50
60
60
60
60
60
70
80
90
90
110
125
60
60
60
60
80
90
100
100
125
150
25
30
25
30
40
40
50
50
70
70
20
20
20
25
30
35
40
40
50
60
60
70
60
70
70
80
90
100
125
125
60
70
60
70
80
90
100
110
125
150
30
30
30
30
40
45
50
60
70
70
25
30
25
30
35
35
40
45
60
60

167

528150-YTG-T-0514
ZR078-150 Standard Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

1.5

8.2

5.5

10.0

230

16.0 110.0 24.9

1.5

8.2

5.5

10.0

460

7.8

52.0

12.1

0.8

4.1

2.2

5.0

575

5.7

38.9

8.9

0.6

3.6

1.8

4.0

208

22.4 149.0 35.0

1.5

10.9

5.5

10.0

230

22.4 149.0 35.0

1.5

10.9

5.5

10.0

460

10.6

75.0

16.5

0.8

5.3

2.2

5.0

575

7.7

54.0

12.0

0.6

4.1

1.8

4.0

120
(10)

150
(12.5)

Electric Heat Option
Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

57.2
69.6
85.2
111.2
163.6
57.2
76.9
94.9
125.0
152.7
28.3
38.4
47.5
62.5
76.3
21.6
31.2
38.4
50.4
61.5
77.3
77.3
88.6
114.6
167.0
77.3
80.3
98.3
128.4
156.0
37.4
39.9
49.0
64.0
77.8
27.8
31.8
39.0
51.0
62.1

62.7
76.5
92.1
118.1
170.5
62.7
83.8
101.8
131.9
159.5
30.5
41.2
50.2
65.2
79.1
23.4
33.4
40.6
52.6
63.7
82.8
82.8
95.5
121.5
173.9
82.8
87.1
105.2
135.2
162.9
39.6
42.7
51.7
66.7
80.6
29.6
34.0
41.2
53.3
64.3

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
70
70
70
80
90
100
125
125
175
175
70
70
80
90
100
110
125
150
175
175
35
35
40
45
50
60
70
70
90
90
25
25
35
35
40
45
60
60
70
70
90
100
90
100
90
100
125
125
175
175
90
100
90
100
100
110
150
150
175
175
45
50
45
50
50
60
70
70
90
90
35
35
35
35
40
45
60
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

168

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR037-061 Hi Static Indoor Blower - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

8.7

68

13.5

1.5

6.0

5.5

10.0

230

8.7

68

13.5

1.5

6.0

5.5

10.0

460

4.6

34

7.1

0.8

3.0

2.2

5.0

575

3.5

28

5.5

0.6

2.4

1.8

4.0

208

11.9

88

18.5

1.5

6.0

5.5

10.0

230

11.9

88

18.5

1.5

6.0

5.5

10.0

460

5.2

44

8.1

0.8

3.0

2.2

5.0

575

4.8

36

7.5

0.6

2.4

1.8

4.0

208

14.1

88

22.0

1.5

4.3

5.5

10.0

230

14.1

88

22.0

1.5

4.3

5.5

10.0

460

7.7

55

12.0

0.8

2.1

2.2

5.0

575

5.1

36

7.5

0.6

2.0

1.8

4.0

037
(3)

049
(4)

061
(5)

Electric Heat Option

MCA
(Amps)

MCA1
w/Pwr
Exh
(Amps)

28.7
28.7
35.6
43.6
59.2
28.7
29.0
38.0
47.1
65.1
14.7
14.7
19.0
23.5
32.6
11.5
18.8
26.0
33.9
35.6
43.6
59.2
72.0
33.9
38.0
47.1
65.1
80.1
16.1
19.0
23.5
32.6
40.1
13.6
18.8
26.0
32.1
37.4
37.4
44.6
60.2
73.0
83.5
37.4
39.0
48.1
66.1
81.1
93.2
19.6
19.6
24.0
33.1
40.6
46.6
14.3
19.2
26.4
32.4
37.2

34.2
34.9
42.5
50.5
66.1
34.2
35.9
44.9
53.9
72.0
16.9
17.3
21.8
26.3
35.3
13.3
21.1
28.3
39.4
42.5
50.5
66.1
78.9
39.4
44.9
53.9
72.0
87.0
18.3
21.8
26.3
35.3
42.8
15.4
21.1
28.3
34.3
42.9
43.5
51.5
67.1
79.9
90.3
42.9
45.9
54.9
73.0
88.0
100.0
21.8
22.3
26.8
35.8
43.3
49.3
16.1
21.5
28.7
34.7
39.5

1

Model

kW

Stages

Amps

None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E03
E06
E08
E15
None
E08
E15
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E06
E08
E15
E20
None
E08
E15
E20
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E06
E08
E15
E20
E23
None
E08
E15
E20
E23

2.3
4.5
6.8
11.3
3
6
9
15
3
6
9
15
9
15
4.5
6.8
11.3
15
6
9
15
20
6
9
15
20
9
15
20
4.5
6.8
11.3
15
18
6
9
15
20
24
6
9
15
20
24
9
15
20
24

1
1
1
2
1
1
1
2
1
1
1
2
1
2
1
1
2
2
1
1
2
2
1
1
2
2
1
2
2
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
1
2
2
2

6.4
12.5
18.9
31.4
7.2
14.4
21.7
36.1
3.6
7.2
10.8
18.0
8.7
14.4
12.5
18.9
31.4
41.6
14.4
21.7
36.1
48.1
7.2
10.8
18.0
24.1
8.7
14.4
19.2
12.5
18.9
31.4
41.6
50.0
14.4
21.7
36.1
48.1
57.7
7.2
10.8
18.0
24.1
28.9
8.7
14.4
19.2
23.1

2

Max Fuse2/ Max Fuse3 /
Breaker3 Breaker
Size w/
Size
Pwr Exh
(Amps)
(Amps)
35
35
40
45
60
35
35
40
50
70
15
15
20
25
35
15
20
30
45
45
45
60
80
45
45
50
70
90
20
20
25
35
45
15
20
30
35
50
50
50
70
80
90
50
50
50
70
90
100
25
25
25
35
45
50
15
20
30
35
40

40
40
45
60
70
40
40
45
60
80
20
20
25
30
40
15
25
30
50
50
60
70
80
50
50
60
80
90
20
25
30
40
45
20
25
30
35
50
50
60
70
80
100
50
50
60
80
90
100
25
25
30
40
45
50
20
25
30
35
40

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Johnson Controls Unitary Products

169

528150-YTG-T-0514

ZR078-150 Hi Static Motor - With Powered Convenience Outlet
Size
(Tons)

Volt

Compressors
(each)
RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

13.5

88.0

21.1

1.5

8.2

5.5

10.0

230

13.5

88.0

21.1

1.5

8.2

5.5

10.0

460

6.0

44.0

9.3

0.8

4.1

2.2

5.0

575

4.9

34.0

7.7

0.6

3.6

1.8

4.0

208

13.1

83.1

20.5

1.5

10.9

5.5

10.0

230

13.1

83.1

20.5

1.5

10.9

5.5

10.0

460

6.1

41.0

9.5

0.8

5.3

2.2

5.0

575

4.4

33.0

6.8

0.6

4.1

1.8

4.0

208

14.5

98.0

22.6

1.5

10.9

5.5

10.0

230

14.5

98.0

22.6

1.5

10.9

5.5

10.0

460

6.3

55.0

9.9

0.8

5.3

2.2

5.0

575

6.0

41.0

9.4

0.6

4.1

1.8

4.0

078
(6.5)

090
(7.5)

102
(8.5)

170

Electric Heat Option
Model

kW

None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36
None
E09
E18
E24
E36

6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
6.8
13.5
18.0
25.5
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0
9.0
18.0
24.0
34.0

MCA1
(Amps)

MCA1
w/Pwr
Exh
(Amps)

51.6
51.6
69.6
85.2
111.2
51.6
51.6
76.9
94.9
125.0
24.2
24.9
38.4
47.5
62.5
19.8
20.3
31.2
38.4
50.4
53.4
53.4
73.0
88.6
114.6
53.4
53.4
80.3
98.3
128.4
25.6
26.4
39.9
49.0
64.0
19.2
21.0
31.8
39.0
51.0
56.5
56.5
73.0
88.6
114.6
56.5
56.5
80.3
98.3
128.4
26.1
26.4
39.9
49.0
64.0
22.8
22.8
31.8
39.0
51.0

57.1
57.1
76.5
92.1
118.1
57.1
57.1
83.8
101.8
131.9
26.4
27.7
41.2
50.2
65.2
21.6
22.6
33.4
40.6
52.6
58.9
58.9
79.8
95.5
121.5
58.9
60.1
87.1
105.2
135.2
27.8
29.2
42.7
51.7
66.7
21.0
23.2
34.0
41.2
53.3
62.0
62.0
79.8
95.5
121.5
62.0
62.0
87.1
105.2
135.2
28.3
29.2
42.7
51.7
66.7
24.6
24.6
34.0
41.2
53.3

Stages Amps
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2
1
2
2
2

18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7
18.9
37.5
50.0
70.8
21.7
43.3
57.7
81.8
10.8
21.7
28.9
40.9
8.7
17.3
23.1
32.7

2
Max Fuse2/ Max Fuse3 /
Breaker
Breaker3
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
60
70
60
70
70
80
90
100
125
125
60
70
60
70
80
90
100
110
125
150
30
30
30
30
40
45
50
60
70
70
20
25
25
25
35
35
40
45
60
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
90
90
100
110
150
150
30
30
30
30
40
45
50
60
70
70
20
25
25
25
35
35
40
45
60
60
70
70
70
70
80
80
90
100
125
125
70
70
70
70
90
90
100
110
150
150
30
30
30
30
40
45
50
60
70
70
25
30
25
30
35
35
40
45
60
60

Johnson Controls Unitary Products

528150-YTG-T-0514
ZR078-150 Hi Static Motor - With Powered Convenience Outlet (Continued)
Size
(Tons)

Compressors
(each)

Volt

RLA LRA

MCC

OD Fan
Motors
(each)

Supply
Blower
Motor

Pwr
Exh
Motor

Pwr
Conv
Outlet

FLA

FLA

FLA

FLA

208

16.0 110.0 24.9

1.5

10.9

5.5

10.0

230

16.0 110.0 24.9

1.5

10.9

5.5

10.0

460

7.8

52.0

12.1

0.8

5.3

2.2

5.0

575

5.7

38.9

8.9

0.6

4.1

1.8

4.0

208

22.4 149.0 35.0

1.5

16.1

5.5

10.0

230

22.4 149.0 35.0

1.5

16.1

5.5

10.0

460

10.6

75.0

16.5

0.8

8.1

2.2

5.0

575

7.7

54.0

12.0

0.6

6.0

1.8

4.0

120
(10)

150
(12.5)

Electric Heat Option

MCA1
(Amps)

Model

kW

None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54
None
E18
E24
E36
E54

13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
13.5
18.0
25.5
40.6
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0
18.0
24.0
34.0
54.0

Stages Amps
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0
37.5
50.0
70.8
112.7
43.3
57.7
81.8
129.9
21.7
28.9
40.9
65.0
17.3
23.1
32.7
52.0

59.9
73.0
88.6
114.6
167.0
59.9
80.3
98.3
128.4
156.0
29.5
39.9
49.0
64.0
77.8
22.1
31.8
39.0
51.0
62.1
82.5
82.5
95.1
121.1
173.5
82.5
86.8
104.8
134.9
162.5
40.2
43.4
52.5
67.5
81.3
29.7
34.2
41.4
53.4
64.5

MCA1
w/Pwr
Exh
(Amps)
65.4
79.8
95.5
121.5
173.9
65.4
87.1
105.2
135.2
162.9
31.7
42.7
51.7
66.7
80.6
23.9
34.0
41.2
53.3
64.3
88.0
88.0
102.0
128.0
180.4
88.0
93.6
111.7
141.7
169.4
42.4
46.2
55.2
70.2
84.1
31.5
36.4
43.6
55.6
66.7

2
Max Fuse2/ Max Fuse3 /
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
70
80
80
80
90
100
125
125
175
175
70
80
90
90
100
110
150
150
175
175
35
35
40
45
50
60
70
70
90
90
25
25
35
35
40
45
60
60
70
70
100
110
100
110
100
110
125
150
175
200
100
110
100
110
110
125
150
150
175
175
50
50
50
50
60
60
70
80
90
90
35
35
35
40
45
45
60
60
70
70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

Electric Heat Multipliers
Voltage
Nominal
240
480
600

Applied
208
230
460
575

kW Capacity Multipliers1
0.75
0.92
0.92
0.92

1. Electric heaters are rated at nominal voltage. Use this table to determine the electric heat
capacity for heaters applied at lower voltages.

Johnson Controls Unitary Products

171

528150-YTG-T-0514

Typical Wiring Diagrams
ZH/ZJ037-150 Typical Wiring Diagrams
Typical ZH/ZJ037-061 Cooling Unit with Gas Heat 230 Volt Wiring Diagram

172

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZR037-061 Reheat Unit with Gas Heat 230 Volt Wiring Diagram

Johnson Controls Unitary Products

173

528150-YTG-T-0514
Typical ZH/ZJ037-061 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram

174

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZR037-061 Reheat Unit with Gas Heat 460/575 Volt Wiring Diagram

Johnson Controls Unitary Products

175

528150-YTG-T-0514
Typical ZH/ZJ037-061 Cooling Unit with/without Electric Heat Wiring Diagram

176

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZR037-061 Reheat Unit with/without Electric Heat Wiring Diagram

Johnson Controls Unitary Products

177

528150-YTG-T-0514
Typical ZH/ZJ/ZR078-120 Cooling Unit with Gas Heat 230 Volt Wiring Diagram

178

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZH/ZJ/ZR078-120 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram

Johnson Controls Unitary Products

179

528150-YTG-T-0514
Typical ZH/ZJ/ZR078-120 Cooling Unit with/without Electric Heat Wiring Diagram

180

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZH/ZJ/ZR150 Cooling Unit with Gas Heat 230 Volt Wiring Diagram

Johnson Controls Unitary Products

181

528150-YTG-T-0514
Typical ZH/ZJ/ZR150 Cooling Unit with Gas Heat 460/575 Volt Wiring Diagram

182

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZH/ZJ/ZR150 Cooling Unit with/without Electric Heat Wiring Diagram

Johnson Controls Unitary Products

183

528150-YTG-T-0514
Typical ZR037-061 Reheat Wiring Diagram

184

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZR078-120 Reheat Wiring Diagram

Johnson Controls Unitary Products

185

528150-YTG-T-0514
Typical ZR150 Reheat Wiring Diagram

186

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZH/ZJ078-150 Factory Installed VFD (Option)

Johnson Controls Unitary Products

187

528150-YTG-T-0514
Typical ZH/ZJ078-150 Factory Installed VFD with Manual Bypass (Option)

188

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZH/ZJ078-150 BAS Ready Unit with Factory Installed VFD (Option)

Johnson Controls Unitary Products

189

528150-YTG-T-0514
Typical ZH/ZJ078-150 BAS Ready Unit with Factory Installed VFD and Manual Bypass (Option)

190

Johnson Controls Unitary Products

528150-YTG-T-0514
Typical ZH/ZJ078-150 VFD Ready Unit (Option)

Johnson Controls Unitary Products

191

528150-YTG-T-0514

Weights and Dimensions
ZH/ZJ037-150 Unit Weights
Unit 4 Point Load Weight

Unit 6 Point Load Weight

FRONT

FRONT
LEFT

LEFT

B

C

B

A

A

E
F

D

Y

X

FRONT

LEFT

Weight (lbs.)
Center of Gravity
Size
Model
(Tons)
Shipping Operating
X
Y
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)
037
(3)
049
(4)
061
(5)
078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)

192

D

C

4 Point Load Location (lbs.)
A
B
C
D

A

6 Point Load Location (lbs.)
B
C
D
E

F

ZH

728

723

40

26

175

143

182

223

121

105

92

117

134

154

ZH

768

763

40

26

185

151

192

235

128

111

97

124

141

162

ZH

869

864

40

26

210

171

217

266

145

126

110

140

160

184

ZH

915

910

38

24

212

158

230

309

149

121

100

147

177

217

ZH

915

910

38

24

212

158

230

309

149

121

100

147

177

217

ZH

1052

1047

38

24

244

182

265

356

171

139

116

169

203

249

ZH

1095

1090

38

24

254

189

276

371

178

145

120

176

211

260

ZH

1285

1280

48

24

240

281

410

350

156

173

192

280

252

227

ZJ

745

740

40

26

180

147

186

228

124

108

95

120

137

157

ZJ

780

775

40

24

174

142

207

253

120

104

91

133

152

175

ZJ

775

770

40

24

172

141

205

251

119

103

91

132

151

174

ZJ

1035

1030

39

25

245

191

260

333

170

144

122

167

195

232

ZJ

1055

1050

39

25

250

195

265

340

174

146

125

170

199

236

ZJ

1065

1060

38

24

247

184

268

360

173

141

117

171

206

253

ZJ

1075

1070

39

24

245

191

278

357

170

143

122

178

209

248

ZJ

1285

1280

48

24

240

281

410

350

156

173

192

280

252

227

Johnson Controls Unitary Products

528150-YTG-T-0514

Weights and Dimensions
ZR037-150 Unit Weights
Unit 4 Point Load Weight

Unit 6 Point Load Weight

FRONT

FRONT
LEFT

LEFT

B

C

B

A

A

D

C
E
F

D

Y

X

FRONT

LEFT

Weight (lbs.)
Center of Gravity
Size
Model
(Tons)
Shipping Operating
X
Y

4 Point Load Location (lbs.)
A
B
C
D

A

6 Point Load Location (lbs.)
B
C
D
E

F

037
(3)

ZR

872

867

40.3

25.5

205

170

223

269

141

124

110

144

163

185

049
(4)

ZR

885

880

40.9

25.1

202

172

232

273

139

124

112

151

168

187

061
(5)

ZR

872

867

41

25

198

169

230

269

136

122

110

150

166

184

ZR

962

957

38

23

214

159

249

335

150

122

101

159

191

234

ZR

970

965

38

23

216

161

251

337

151

123

102

160

193

236

ZR

1205

1200

38

25.5

297

221

291

390

208

170

141

185

223

274

ZR

1205

1200

38

25.5

297

221

291

390

208

170

141

185

223

274

ZR

1470

1465

51

25.5

270

363

477

355

172

207

254

334

272

226

078
(6.5)
090
(7.5)
102
(8.5)
120
(10)
150
(12.5)

Johnson Controls Unitary Products

193

528150-YTG-T-0514

ZH/ZJ/ZR037-150 Unit Accessory Weights
Unit Accessory
Economizer
Power Exhaust
Electric Heat1
Gas Heat2
Variable Frequency Drive3

Weight (lbs.)
Shipping
Operating
90
85
40
35
49
49
110
110
30
30

1. Weight given is for the maximum heater size available
(54KW).
2. Weight given is for the maximum number of tube heat
exchangers available (8 tube).
3. Weight includes mounting hardware, controls and manual
bypass option (6-1/2 to 12-1/2 ton only).

ZH/ZJ/ZR037-150 Unit Dimensions
ZH/ZJ037-049 and ZR037
29.75
15.51

29.52

59.00

Ø 25.31

B
See detail A for gas inlet

A

C

D

E
11 3/8

F
See detail B for drain location

LEFT

4 3/16
FRONT

59

21 3/16

27 5/16
89

194

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH/ZJ 061, ZR049 - 061 and ZH/ZJ/ZR078 thru 120

29.69
15.25

15.38

59.00

15.38

2X Ø 24.38

B
SEE DETAIL A FOR GAS INLET

A

C
D
E
11.38

F

59.00

4.19

LEFT

27.31

SEE DETAIL B
FOR DRAIN LOCATION
21.19
89.00
FRONT

Johnson Controls Unitary Products

195

528150-YTG-T-0514
ZH/ZJ/ZR150

28.86

29.66
44.09
15.23

14.85
29.03

29.03
14.85

Ø 24.58 TYP. 4 PL.

15.23

B
See detail A for gas inlet

A

C
D
E

11 3/8
F
See detail B for drain location

LEFT

4 3/16

59

21 3/16
FRONT

27 5/16
89

ZH/ZJ/ZR037-150 Unit Physical Dimensions
Unit Model Number
ZH037, 049, 061, 078, 090
ZH102, 120
ZH150
ZJ037, 049, 061
ZJ078, 090, 102, 120
ZJ150
ZR037, 049, 061
ZR078, 090
ZR102, 120
ZR150

196

A
42
50 3/4
50 3/4
42
50 3/4
50 3/4
42
42
50 3/4
50 3/4

B
89
89
119 1/2
89
89
119 1/2
89
89
89
119 1/2

Dimension (in.)
C
22 1/8
18
30 3/16
24
30 3/16
24
22 1/8
18
30 3/16
24
30 3/16
24
22 1/8
18
22 1/8
18
30 3/16
24
30 3/16
24

D
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16

15
17
17
15
17
17
15
15
17
17

E
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16

6
6
6
6
6
6
6
6
6
6

F
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16

Johnson Controls Unitary Products

528150-YTG-T-0514
Detail A
3.184

3.184

Gas Pipe Inlet

Gas Pipe Inlet

Ø 2.000

Ø 2.000

Gas Exhaust Vent

Gas Exhaust Vent

Ø 3.126

Ø 3.126
17.541

14.594

7.715

7.705

4.737

4.727

42” CABINET

50 3/4” CABINET

Detail B
ZH/ZJ/ZR037-150 Unit Clearances
Direction
Top1
Front
Rear

5-3/8

Distance (in.)
72
36
36

Direction
Right
Left
Bottom2

Distance (in.)
12
36
0

1. Units must be installed outdoors. Over hanging structure or
shrubs should not obscure condenser air discharge outlet.
2. Units may be installed on combustible floors made from wood
or class A, B or C roof covering materials.

3/4” FPT

Johnson Controls Unitary Products

197

528150-YTG-T-0514
ZH/ZJ/ZR037-150 Unit Bottom Duct Openings

TOP VIEW
89
32 11/16
6 13/16

6 13/16
SUPPLY
AIR

RETURN
AIR

27 1/2
LEFT

18

24

RIGHT

21

20 1/8 19 1/8
17 1/8
12 5/16

Bottom condensate drain

14 1/2

25 9/16

Bottom gas
supply entry

16 3/8
18 1/16

FRONT

Bottom power, control
and convenience outlet
wiring entry

3X Ø 0.875

Ø 2.469

198

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH/ZJ/ZR037-150 Unit Electrical Entry

Disconnect Swith Cover

Power Entry Ø 2-1/2

Control Entry Ø 7/8

Power Entry Ø 2-1/2

Convenience Outlet Cover

Convenience Outlet
Power Entry Ø 7/8

FRONT

ZH/ZJ/ZR037-120 Unit Side Duct Openings
Dot Plugs

18-1/4

Return
Air

A

Supply Air
D
B

2-31/32
5-5/32

C
31-11/16

Johnson Controls Unitary Products

199

528150-YTG-T-0514
ZH/ZJ/ZR150 Unit Side Duct Openings
Dot Plugs
18-1/4

A

D
B
5-5/32
2-7/8
C

31-5/8

ZH/ZJ/ZR037-150 Side Duct Dimensions
Unit Model Number
ZH037, 049, 061, 078, 090
ZH102, 120
ZH150
ZJ037, 049, 061
ZJ078, 090, 102, 120
ZJ150
ZR037, 049, 061
ZR078, 090
ZR102, 120
ZR150

200

A
27 3/4
28 1/4
28 1/4
27 3/4
28 1/4
28 1/4
27 3/4
27 3/4
28 1/4
28 1/4

12
18
18
12
18
18
12
12
18
18

Dimension (in.)
B
C
1/16
27 1/2
1/16
28 1/4
1/16
28 1/4
1/16
27 1/2
1/16
28 1/4
1/16
28 1/4
1/16
27 1/2
1/16
27 1/2
1/16
28 1/4
1/16
28 1/4

D
16
18 1/4
18 1/4
16
18 1/4
18 1/4
16
16
18 1/4
18 1/4

Johnson Controls Unitary Products

528150-YTG-T-0514
ZH/ZJ/ZR037-150 Unit Left Duct Opening

30-3/8

4-5/16

ZH/ZJ/ZR037-150 Unit Accessory Dimensions
ZH/ZJ/ZR037-150 Roof Curb

RIGHT
80-5/8

INSULATED DECK UNDER
CONDENSER SECTION

20
SUPPLY
20

6

RETURN
2 TYP.

30
INSULATED DECK UNDER
COMPRESSOR SECTION

50-1/2

8 or 14

Johnson Controls Unitary Products

FRONT

201

528150-YTG-T-0514
ZH/ZJ/ZR037-150 Transition Roof Curb
2 TYP

50-1/2

23 4

30-1/2

80-5/8

26
RETURN
SUPPLY

10

76-5/8
59-1/4

94
FRONT

RIGHT

64-1/4

ZH/ZJ/ZR037-150 Economizer Assembly

58 1/4
88 1/4
24 3/4 Tall Units
26 1/8 Short Units

32 1/16

39 1/2
OR
47 1/2

Fresh Air Hood
For Economizer

Outside Air
Intake Hood

35 3/4
Relief Hood For
Power Exhaust Or
Barometric Relief
26

202

25 3/4

23 3/4

31 7/8

Johnson Controls Unitary Products

528150-YTG-T-0514

Economizer Options
Economizer Usage
Application

Cabinet Height

Description

Model

Side Return

All

Horizontal economizer without barometric relief

2EE047060241

42"

Slab Economizer, 42” tall cabinet

2EE047075242

50"

Slab Economizer, 50” tall cabinet

2EE047083242

ERV or End Return

1. Barometric relief must be ordered separately and installed in duct work.
2. Barometric relief or fresh air hood not included. Must be ordered separately.

Field Installed Horizontal Economizer W/Power Exhaust
Return Air Damper
Field Installed
Duct Work

Fresh Air Damper

Power Exhaust
Barometric
Relief Damper

Barometric
Relief Hood

Fresh Air Hood

Slab Economizer Downflow W/Power Exhaust

Fresh Air Hood

Low Leak Slab Economizer
Power Exhaust
Barometric
Relief Damper

Johnson Controls Unitary Products

Barometric Relief
Hood

203

Slab Economizer End Return W/Power Exhaust

Fresh Air Hood

Field Installed
Duct Work

Slab Low Leak
Economizer
Power Exhaust
Barometric Relief Damper
Barometric Relief Hood

Subject to change without notice. Printed in U.S.A.
Copyright © 2014 by Johnson Controls, Inc. All rights reserved.
York International Corporation
5005 York Drive
Norman, OK 73069

528150-YTG-T-0514
Supersedes: 528150-YTG-S-0414



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : clarchd
Create Date                     : 2004:07:21 16:14:32Z
Modify Date                     : 2014:06:17 13:33:43-05:00
Language                        : en
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.150055, 2012/11/19-18:45:32
Creator Tool                    : FrameMaker 12.0.2
Metadata Date                   : 2014:06:17 13:33:43-05:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Format                          : application/pdf
Title                           : 528150-YTG-T-0514.fm
Creator                         : clarchd
Document ID                     : uuid:55708b7e-24e2-417e-a54c-971852da54a9
Instance ID                     : uuid:0b3bbc5c-d1a1-4fa8-876c-cc9be163b4f4
Page Mode                       : UseOutlines
Page Count                      : 204
EXIF Metadata provided by EXIF.tools

Navigation menu