Yulong Computer Telecommunication Scientific YLWM0404 Wireless Data Modem User Manual 419825

Yulong Computer Telecommunication Scientific (Shenzhen) Co. LTD Wireless Data Modem 419825

users manual

Download: Yulong Computer Telecommunication Scientific YLWM0404 Wireless Data Modem User Manual 419825
Mirror Download [FCC.gov]Yulong Computer Telecommunication Scientific YLWM0404 Wireless Data Modem User Manual 419825
Document ID419825
Application ID5h+7dFv6AcVqscsaNAwoGw==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize13.68kB (171009 bits)
Date Submitted2004-05-04 00:00:00
Date Available2004-05-04 00:00:00
Creation Date2004-05-05 07:21:57
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-05-05 07:21:57
Document TitleMicrosoft Word - 419825.DOC
Document CreatorPScript5.dll Version 5.2
Document Author: Administrator

Modem setup manual
1. PC requirement: must have a Serial COM , Operation System can use Windows 98 or
Windows 2000.
2. Connect PC and PIP900 modem
PI P900
COM
TALK / DATA
TALK
RS CS TR RD TD CD
POWER I N
PC
AC I N
AC
ADAPTER
7V- 12VDC
PI P900 CONNECT WI TH PC
diagram 1: Connect PC and PIP900 modem
3. Start modemsetup software
There are two dialogs in the modemsetup software. The first dialog is SETUP (diagram 2 and
diagram 3). This dialog used to setup COM parameter. After finished set COM parameter, push the
Connect[C] button to connect the PIP900 modem. The second dialog is Test Transmit (diagram 3).
This dialog used to select Transmit Power, Modulate Data kinds and Transmit Duty. If you want to
output Max Power, please select Power level 4(MAX). Operation Step:
a. Connect PC and PIP900 use special cable.
b. In SETUP dialog select the COM (COM1 or COM2 etc.) then push the Open[O] button to
open COM port, If success to connect the PIP900 modem, you can change to the Test
Transmit dialog to test the modem transmit functions.
c. In Test Transmit dialog, select Power Level 4(Max) in functions window. You may
change Modulation kinds and Transmit Duty value then select Send button to send
command to PIP900. (Note: items means in the Modulation kinds, only 1 means positive
frequency deviation, only 0 means negative frequency deviation, center means center
frequency, PN9 scramble means use PN9 modulation data, dynamic frequency use to test
dynamic frequency deviation)
d. The continuous transmission of a modulation carrier (PN9 modulation or dynamic
frequency with fixed Data modulation) for longer periods when you set the Duty_off
to 0. but you can’t change the parameters again in this mode, till you reset the
pip900 modem(by power down).
e. The item others may not use.
diagram 2:SETUP menu 1
diagram 3 : SETUP menu 2
diagram 4:Test Transmit menu
FCC Part 2 certification requires all integrated products to have
routine environmental evaluation for radio-frequency (RF) exposure
prior to equipment authorization or use in accordance with FCC rules
2.1091 and 2.1093 and FCC Guidelines for Human Exposure to Radio
Frequency Electromagnetic Fields, OET Bulletin 65 and its
Supplement C.
For “mobile or fixed devices”, defined as transmitting devices
designed to be generally used such that a separation distance of at least
20 cm is maintained between the body of the user and the transmitting
radiated structure, Maximum Permissible Exposure (MPE) limits may
be used with field strength or power density limit of 0.597 mW/cm2 (at
896 MHz).
"To satisfy FCC RF exposure requirements a separation
distance of 20 cm or more should be maintained between the
antenna of this device and persons during device operation. To
ensure compliance, operations at closer than this distance is not
recommended."
“Regulatory Notice of Compliance
This equipment has been tested and found to comply within the
limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.”

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2004:05:05 07:21:57-04:00
Modify Date                     : 2004:05:05 07:21:57-04:00
Page Count                      : 4
Creation Date                   : 2004:05:05 11:21:57Z
Mod Date                        : 2004:05:05 11:21:57Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Administrator
Metadata Date                   : 2004:05:05 11:21:57Z
Creator                         : Administrator
Title                           : Microsoft Word - 419825.DOC
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R38YLWM0404

Navigation menu