ZKTECO KR611DR Card Reader User Manual RSKR611D RS

ZKTECO CO., LTD. Card Reader RSKR611D RS

Users Manual

KR610D-RS User manual1 Overview KR61*D-RS 13.56MHZ Contactless IC card reader, is based on ISO / EM4001 international standard protocol development of non-contact smart card serial number reader. It uses the company's own design of high-performance RF card reader circuit design; with a high degree of integration, anti-interference ability, small size, stable performance, cost-effective features. Can provide RS485 and Wiegand communication interface for access control, time and attendance, fees, security, Patrol and other radio frequency identification applications。 2. FeaturesThe card reader is equipped with a card-reading antenna that works at 13.56MHz.The effective distance ranges from 0 to 5cm, depending on the working environment and card type.The data receiving time is less than 80ms within the effective distance.The  card  reader  adopts  the  single  +12  VDC  power  supply,  and  the  operating  current  is  less  than100mA.The  data  is  output  in  the  standard  Wiegand34 bits  format  by  default.  The  format  can  be  convertedbetween Wiegand34 and Wiegand66.The  card  reader  is  produced  using  the  fully  closed  rubber  injecting  operation  to  achieve  thewaterproof and moisture-proof effects.The effective distance is associated with the voltage of the power supply, used IC cards, and operatingenvironment.3. Wire Function DescriptionRed wire: VCC; +12V Black wire: GND   Green wire: Wiegand D0 White wire: Wiegand D1 Grey wire: Green LED Purple wire: Beeper Yellow wire: NC Blue wire:    485- Orange wire :485+
4. Specifications4.1 Limit Parameters 4.2    Electrical, mechanical properties  (No special instructions TA=25,Vcc=12V) project Min typical Max  unit +12V,Vcc 7  12  14  V Working current,Ic  70  110  mA working frequency,FRES  13.52  13.56  13.58  MHz effective distance,D *  20  30  40  mm Decoding time,TDEC  65  100  ms Data0,Data1,Hold/ ata,Clock,Card, Present,Output  high potential, VoH 2.4(IoH=80uA), 0.75Vcc(IoH=30uA) V 0.9Vcc(IoH=12uA) Data0,Data1,Hold/ ata,Clock,Card, Present  Output  low potential,VoL 0.5 ( IoL=20mA,Vcc=5V,IoL=20mA,Vcc=3.3V) V R485+,R485-Input voltage -7<Output<12 V R485+,R485-output voltage -7<Output<12 V project Value unit +12V,Vcc 12.5  V Data0,I0/Clock,ICK  20mA Data1,I1/Data,IC     20mA R485-  200mA R485+   200mA Hold,IH/Card Present,ICP  25mA antenna ,IAN  43mA Operating temperature ,TOPR  -1070 CStorage temperature ,TSTR  -55~+125 C
5. Connections5.1    Wiegand Connections5.2    485 Connections 6    Precautions 1. The  operating  frequency  of  the  card  reader  is  13.56MHz.  Therefore,  interference  frequency  ranging
from 13MHz to 15MHz cannot exist on the site where the card reader is installed. 2. To prevent emission magnetic fields of card readers from affecting each other, the installation distancebetween every two card readers must be greater than 10 cm.Attachment 1
"Hereby, ZKTECO CO., LTD. declares that this Card Reader is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and(2) This device must accept any interference received,including interference that may cause undesired operation.Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device,   pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against   harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver isconnected.Consult the dealer or an experienced radio/TV technician for help.
Manufacturer: ZKTECO CO., LTD. Address: No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong Province, China Importers: ZKTECO EUROPE SRL Address: AVDA CAMINO DE LO CORTAO(DE), NUM.10, PLANTA NAV, PUERTA 1 POLIGONO INDUSTRIAL SUR- S SEBASTIAN DE LOS REYES, 28703, MADRID