ZTE MW3650 WCDMA Module User Manual

ZTE Corporation WCDMA Module

Users Manual

                           Hardware Development Guide of Module Product   Version V1.0, 2015-09-28  MW3650
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    II    MW36500 Legal Information  By receiving the document from Shenzhen ZTEWelink Technology Co., Ltd (shortly referred to as ZTEWelink),  you are deemed to  have agreed  to the following terms.  If you don’t agree  to  the following terms, please stop using the document.  Copyright © 2015 Shenzhen ZTEWelink Technology Co., Ltd. All rights reserved. The document contains  ZTEWelink’s  proprietary  information.  Without  the  prior  written  permission  of ZTEWelink, no entity or individual is allowed to reproduce, transfer, distribute, use and disclose this document or any image, table, data or other information contained in this document.    is the registered trademark of ZTEWelink. The name and logo of ZTEWelink are ZTEWelink’s trademark or registered trademark. Meanwhile, ZTEWelink is granted to use ZTE Corporation’s  registered  trademark.  The  other  products  or  company  names  mentioned  in  this document are the trademark or registered trademark of their respective owner. Without the prior written  permission  of  ZTEWelink  or  the  third-party  oblige,  no  one  is  allowed  to  read  this document.  The product meets the design requirements of environmental protection and personal security. The storage, use or disposal of products should abide by the product manual, relevant contract or the laws and regulations of relevant country.    ZTEWelink reserves the right to make modifications on the product described in this document without prior notice, and keeps the right to revise or retrieve the document any time.    If you have any question about the manual, please consult the company or its distributors promptly.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    III    MW36500  Revision History Version  Date  Description 1.0  2015-09-28  1st released version
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    IV    MW36500  Contents Figures ................................................................................................................................................. VII Tables ................................................................................................................................................. VIII 1  About This Document .................................................................................................................. 10 1.1  Application Range ......................................................................................................... 10 1.2  Purpose .......................................................................................................................... 10 1.3  Supported & Reference Documents List ....................................................................... 11 1.4  Abbreviations ................................................................................................................ 11 2  Product Overview ......................................................................................................................... 13 2.1  Technical Parameters ..................................................................................................... 14 2.2  Function Overview ........................................................................................................ 16 2.2.1  Baseband Function ................................................................................................ 16 2.2.2  Radio Frequency Function .................................................................................... 16 3  Mechanic Features ....................................................................................................................... 18 3.1  Module Illustration ........................................................................................................ 18 3.2  Module hex-vision images ............................................................................................ 19 3.3  Module Main Board PCB Encapsulation Dimension Diagram ..................................... 19 3.4  PCB Design Guidelines ................................................................................................. 21 3.5  Suggestions for Heat-dissipation Design ....................................................................... 22 4  Interfaces....................................................................................................................................... 23 4.1  Definition of PINs ......................................................................................................... 23 4.2  Hardware interface description ...................................................................................... 27 4.3  Ground ........................................................................................................................... 28 4.4  Power Interface .............................................................................................................. 28 4.4.1  V_MAIN PINS ..................................................................................................... 28 4.4.2  VREF PINS ........................................................................................................... 30 4.4.3  Power interface PCB Layout and Wiring Guidance .............................................. 30 4.5  Power-on/Power-off & Reset......................................................................................... 31 4.5.1  Power On .............................................................................................................. 31
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    V    MW36500 4.5.2  Power Off .............................................................................................................. 31 4.5.3  Reset ...................................................................................................................... 32 4.5.4  Power-on/Power-off Flow ..................................................................................... 32 4.6  UART Interface ............................................................................................................. 34 4.7  (U)SIM Card Interface .................................................................................................. 36 4.8  USB Interface ................................................................................................................ 38 4.9  Working Status Indicator Interface ................................................................................ 39 4.10  SPI Bus Interface ........................................................................................................... 40 4.11  I2C Bus .......................................................................................................................... 41 4.12  User Interface ................................................................................................................ 42 5  Antenna ......................................................................................................................................... 43 5.1  Preliminary Antenna Evaluation .................................................................................... 43 5.2  Antenna Design Guidance ............................................................................................. 43 5.3  Suggested Antenna Location ......................................................................................... 44 5.4  RF PCB wire guidelines ................................................................................................ 45 5.5  EMC Requirements ....................................................................................................... 45 5.6  Index Requirement of Antenna ...................................................................................... 46 5.6.1  Passive Index of Antenna ...................................................................................... 46 5.6.2  Active Index of Antenna ....................................................................................... 47 5.6.3  OTA Test method of Whole Machine Antenna ...................................................... 48 6  Electric Feature ............................................................................................................................ 49 6.1  Interface PWL ............................................................................................................... 49 6.2  Power Supply ................................................................................................................ 49 6.3  Working Current ............................................................................................................ 49 7  Technical Index of Radio Frequency .......................................................................................... 51 7.1  Index of RF under UMTS Mode ................................................................................... 51 7.1.1  Maximum Transmission Power ............................................................................. 51 7.1.2  Receiving Sensibility ............................................................................................ 52 7.1.3  Spurious Emission Index ....................................................................................... 52 7.2  Index of RF under GPRS/GSM/EDGE Mode ............................................................... 52 7.2.1  Maximum Transmission Power ............................................................................. 53 7.2.2  Receiving Sensibility ............................................................................................ 53
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    VI    MW36500 7.2.3  Spurious Emission Index ....................................................................................... 53 8  Related Test & Test Standard ...................................................................................................... 55 8.1  Testing Reference .......................................................................................................... 55 8.2  Description of Testing Environment .............................................................................. 56 8.3  Reliability Testing Environment .................................................................................... 56 8.4  Reliability Testing Result .............................................................................................. 57 8.5  ESD Characteristic ........................................................................................................ 58 9  SMT Process and Baking Guide ................................................................................................. 59 9.1  Storage Requirements .................................................................................................... 59 9.2  Module’s Position Requirements on Main board .......................................................... 59 9.3  Module Planeness Standard ........................................................................................... 60 9.3.1  Process Routing Selection ..................................................................................... 60 9.3.2  Solder Paste Selection ........................................................................................... 60 9.3.3  Design of module PAD’s steel mesh opening on main board................................ 61 9.3.4  Module Board’s SMT process ............................................................................... 62 9.3.5  Module Soldering Reflow Curve .......................................................................... 63 9.3.6  Reflow method ...................................................................................................... 64 9.3.7  Maintenance of defects ......................................................................................... 64 9.4  Module’s Baking Requirements .................................................................................... 64 9.4.1  Module’s Baking Environment ............................................................................. 64 9.4.2  Baking device and operation procedure ................................................................ 65 9.4.3  Module Baking Conditions ................................................................................... 65 10  Safety Warnings and Notes .......................................................................................................... 66
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    VII    MW36500  Figures Figure 2-1    System Connection Structure ............................................................................. 16 Figure 4-1    PIN Configuration Diagram ............................................................................... 23 Figure 4-2    Wakeup Waveform .............................................................................................. 26 Figure 4-3    LDO Power Supply ............................................................................................ 29 Figure 4-4    DC/DC Switching Power Supply ....................................................................... 30 Figure 4-5    Power On & Reseting Circuit Reference Diagram ............................................. 31 Figure 4-6    Power-on Sequence Chart of Module ................................................................. 33 Figure 4-7    Power-off Sequence Chart of Module ................................................................ 33 Figure 4-8    UART Interface PWL Conversion Reference Design ........................................ 35 Figure 4-9    Module Serial Port & AP Application Processor ............................................... 35 Figure 4-10    The Connection of UART and Standard RS-232-C Interface .......................... 36 Figure 4-11    (U)SIM Card Console Circuit Reference Design ............................................. 37 Figure 4-12    USB Interface Circuit Reference Design Schematic Diagram ......................... 39 Figure 5-1    Translation Circuit Diagram ............................................................................... 44 Figure 5-2    OTA Test System ............................................................................................... 48 Figure 9-1    Green oil and white oil at module’s position on main board .............................. 60 Figure 9-2    Module Board’s Steel Mesh Diagram ................................................................ 62 Figure 9-3    Material Module Pallet ....................................................................................... 62 Figure 9-4    Module Furnace Temperature Curve Diagram ................................................... 63
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    VIII    MW36500  Tables Table 1-1    Support Documents List ...................................................................................... 11 Table 1-2    Abbreviation List ................................................................................................. 11 Table 2-1    Module Frequency band configuration ................................................................ 13 Table 2-2    Major Technical Parameters ................................................................................ 14 Table 2-3    Working Frequency Band .................................................................................... 17 Table 3-1    Product Illustration .............................................................................................. 18 Table 4-1    PIN Interface Definition ...................................................................................... 23 Table 4-2    Voltage Current Characteristic ............................................................................ 29 Table 4-3    Power-on/Power-off Time ................................................................................... 33 Table 4-4    The Definition of UART Signal .......................................................................... 34 Table 4-5    The Definition of USIM Card Interface............................................................... 36 Table 4-6    The Definition of USB PINS ............................................................................... 38 Table 4-7    The Correspondence of Port Map ........................................................................ 39 Table 4-8    Indicator Light Reference Design Schematic Diagram ....................................... 40 Table 4-9    The Description of Working Status Indicator Light ............................................ 40 Table 4-10    The Definition of SPI Interface ......................................................................... 40 Table 4-11    I2C Reference Circuit Design ............................................................................ 41 Table 5-1    The Passive Index Reference of Main Antenna about PAD product ................... 46 Table 5-2    The Passive Index Reference of Diversity Antenna about PAD product ............ 46 Table 5-3    Recommended Product OTA Index Requirement ............................................... 47 Table 6-1    Main Out ward Interface PWL of Module ........................................................... 49 Table 6-2    Input Voltage ....................................................................................................... 49 Table 6-3    The Current Consumption under Sleep Mode ..................................................... 50 Table 6-4    The Working Current of MODULE .................................................................... 50 Table 7-1    Maximum Transmission Power ........................................................................... 51 Table 7-2    Reference of Receiving Sensitivity ...................................................................... 52 Table 7-3    Spurious Emission Index ..................................................................................... 52 Table 7-4    Maximum Transmission Power of GSM850/900/1800/1900 (GMSK/8PSK) .... 53 Table 7-5    Receiving Sensitivity ........................................................................................... 53 Table 8-1    Testing Standard .................................................................................................. 55 Table 8-2    Testing Environment ........................................................................................... 56 Table 8-3    Testing Instrument & Device ............................................................................... 56 Table 8-4    Reliability Features .............................................................................................. 56 Table 8-5    The Temperature Testing Result Under Windless Condition .............................. 57 Table 8-6    The High/low Temperature Running and Storage Testing Result ....................... 57 Table 8-7    Module ESD Features .......................................................................................... 58 Table 9-1    Baking parameters ............................................................................................... 59 Table 9-2    LCC module PAD’s steel mesh opening ............................................................. 61
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    IX    MW36500  R&TTE Regulation: In all cases assessment of the final product must be mass against the Essential requirements of the R&TTE Directive Articles 3.1(a) and (b), safety and EMC respectively, as well as any relevant Article 3.2 requirements.     Hereby,  ZTE  CORPORATION  declares  that  this  product is  in  complies  with  the  essential requirements of Article 3 of the R&TTE 1999/5/EC Directive.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    10    MW36500 1 About This Document 1.1 Application Range This document is applicable as the hardware development guide of MW3650 module produce. Users need to design products according to the requirement and guide of this document. This document only can be applied to the hardware application development of MW3650 module product.  1.2 Purpose This document  provides the hardware solutions and  development fundamentals for a product with the module.  By reading  this  document,  the  user  can  have  an  overall  knowledge  of  the  module  and  a  clear  understanding  of  the technical  parameters.  With  this document,  the  user can successfully fulfill  the  application  and development  of 3G wireless Internet product or equipment. Besides the product  function features  and technical parameters,  this  document also provides the product reliability tests and related testing standards, business function realization process, RF performance indexes and a guide on the design of user circuits, to provide the user with a complete design reference.    NOTE:   At present, our company has a large number of module products. Users may come across many module board welding problems when using the module. To ensure the module board welding first pass yield and guarantee the module manufacturing and welding quality in  the following  integration process, please do  as the chapter 9 of Manufacturing Guide in this document.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    11    MW36500 1.3 Supported & Reference Documents List Besides this hardware development guide, we also provide the Datasheet document, software development guide and AT command reference guide. Table 1-1 is the support document list. Table 1-1    Support Documents List Document NO.  Document Name 1  ZTEWelink Software Development Guide of Module Product(MG3732_V2A&MW3650).pdf 2  ZTEWelink MW3650 Datasheet.pdf 3  AT Command reference guide for ZTEWelink MG3732_V2A,MW3650 Module.pdf 1.4 Abbreviations Table 1-2 is a list of abbreviations involved in this document, as well as the English full names. Table 1-2    Abbreviation List Abbreviations  Full Name ADC  Analog-Digital Converter ARP  Antenna Reference Point BER  Bit Error Rate BTS  Base Transceiver Station CDMA  Code Division Multiple Access CS  Coding Scheme CSD  Circuit Switched Data CPU  Central Processing Unit DAC  Digital-to-Analog Converter DCE  Data Communication Equipment DSP  Digital Signal Processor DTE  Data Terminal Equipment DTMF  Dual Tone Multi-Frequency DTR  Data Terminal Ready EGSM  Enhanced GSM EMC  Electromagnetic Compatibility
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    12    MW36500 Abbreviations  Full Name EMI  Electro Magnetic Interference ESD  Electronic Static Discharge ETS  European Telecommunication Standard FDMA  Frequency Division Multiple Access   FR  Full Rate GPRS  General Packet Radio Service   GSM  Global Standard for Mobile Communications IC  Integrated Circuit IMEI  International Mobile Equipment Identity   ISO  International Standards Organization   ITU  International Telecommunications Union   LCD  Liquid Crystal Display LED  Light Emitting Diode MCU  Machine Control Unit PCB  Printed Circuit Board PCL  Power Control Level PCS  Personal Communication System PDU  Protocol Data Unit PPP  Point-to-point protocol   RAM  Random Access Memory RF  Radio Frequency ROM  Read-only Memory RTC  Real Time Clock SIM  Subscriber Identification Module SMS  Short Message Service SPI  Serial Peripheral Interface TE  Terminal Equipment also referred it as DTE UART  Universal asynchronous receiver-transmitter   UIM  User Identifier Management USB  Universal Serial Bus UMTS  Universal Mobile Telecommunication System WCDMA  Wideband Code Division Multi Access
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    13    MW36500 2 Product Overview MW3650 is a WCDMA/HSDPA/GSM/GPRS/EDGE industry module developed by our company, and it is a wireless Internet module with LCC interface. The module has voice(optional), short message and data service functions. The downlink  peak  data  rate  is  3.6Mbps  and  the  uplink  peak  data  rate  is  384Kbps,  so  it  can  supply  the  users  with economical  high  speed  internet  access  business,  wireless  data  business  and  so  on.  It  is  widely  applied  to  but  not limited to the various products and equipment such as modem, embedded module, wireless phone, multimedia phone and touch screen communication device, PAD, vehicle-mounted terminals and electric consumed devices, using the MW3650 module. The function features of this module are described as bellow: 1) Support  UMTS/HSDPA  850(900)/1900/2100MHz  frequency  band, GSM/GPRS/EDGE  850/900/ 1800/1900MHz frequency band. 2) Can supply GSM/GPRS/EDGE and UMTS/HSDPA  high speed data  access service in a  mobile environment. 3) Support SMS and voice functions. 4) Supply  (U)SIM  card  interface  (3.0V/1.8V),  USB2.0  interface,  8-wire  UART  (compatible  with 2-wire UART), power on/off, reset and so on. Taking MW3650 module as an example, this document introduces the logical structure, hardware interfaces and main function in detail. It also supplies the corresponding design reference of hardware and structure.  NOTE:   At present,  the  frequency  band  of  MW3650  module  in UMTS mode  can  take  proper  tailoring or  configuration according to the corresponding requirement of customers as is shown blow. Table 2-1    Module Frequency band configuration Configuration  GSM Bands  WCDMA Bands MW3650V1A  850/1900MHz  1900/850MHz MW3650V1B  900/1800MHz  2100/900MHz MW3650V1C  900/1800MHz  2100MHz
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    14    MW36500 2.1 Technical Parameters The major features of the module can be described from the aspects of mechanic feature, base band, radio frequency, technical  standard,  environment  features  and  so  on.  Table  below  is  a  list  of  the  major  technical  parameters  and features supported by module.   Table 2-2    Major Technical Parameters Type  Item  Specifications Mechanical Feature Dimensions (L × W × H)  30.0mm × 30..0mm × 2.3mm Weight  About 5g Encapsulation type  LCC with 80 pins Baseband (U)SIM/SIM  Standard SIM card interface 3V SIM card and 1.8V SIM card USB interface  USB 2.0 HIGH SPEED UART interface  8-wire UART Max Power Dissipation   About 2.2W Power Supply  DC 3.3~4.2V, typical value is 3.8V Working Current2 Peak current  About 0.6A The average current in normal working About 540mA@UMTS 2100   About 239mA@GSM 900 Standby current  About 5mA@UMTS About 5mA@GSM RF GSM Frequency Band    EDGE/GPRS/GSM:1900/1800/900/850MHz UMTS Frequency Band    HSDPA/WCDMA:2100/1900/850(900)MHz; Diversity Reception Frequency Band    NA1 Max. Transmitter Power UMTS2100/1900/900/850: Power Class 3 (+24dBm +2.5/-1.5dBm) GSM/GPRS 850MHz/900MHz: Power Class 4 (+33dBm + 2.5/-0.5 dBm) GSM/GPRS 1800MHz/1900MHz: Power Class 1 (+30dBm +2.5/-0.5 dBm) EDGE 850MHz/900MHz: Power Class E2 (+27dBm +4.5/-1.5dBm) EDGE 1800MHz/1900MHz: Power Class E2 (+26dBm +4.5/-2.5dBm)
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    15    MW36500 Type  Item  Specifications Receiving sensitivity WCDMA2100 : ≤-108dBm WCDMA1900 : ≤-109dBm WCDMA900 : ≤-109dBm WCDMA850 : ≤-109 dBm GSM850/900/1800/1900 : ≤-107dBm Main Antenna  External, Provide Antenna    PAD Technical Standard Data Rate GSM CS: UL 9.6kbps/DL 9.6kbps GPRS: Multi-slot Class 10 EDGE: Multi-slot Class 12 WCDMA CS: UL 64kbps/DL 64kbps WCDMA PS: UL 384kbps/DL 384kbps HSDPA  HSDPA: DL 3.6Mb/s(Category 6) Protocol  HSDPA/WCDMA/EDGE/GPRS/GSM 3GPP Protocol  R5, R4, R99 OS Windows XP (SP2 and later) Windows Vista & 7 WinCE Linux Android Environment Feature3 Working Temperature  -30 ~ 75° C Storage Temperature  -40 ~ 85° C Humidity  5%~ 95% Application DATA  Support SMS Support ultra-long SMS Support Text and PDU mode   Point to point MO and MT   Voice  Support MMS  Support (Not support built-in MMS protocol stack temporarily) TCP/IP  Support UDP/IP  Support Phonebook  Support Upgrade  Support
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    16    MW36500  NOTE:   “NA” indicates nonsupport. Working current value is the average value tested under the max transmitter power. The value may be different in different condition and environment. Please take the actual measurement as the reference. Please  make  sure  that  the  module  is  started  up  in  the  recommended  working  current  range  and  working temperature to avoid the damage or the abnormal working of the module. 2.2 Function Overview 2.2.1  Baseband Function When connected with the system board, the module mainly includes the following signal groups: USB signal, (U)SIM card  signal,  status  querying  signal,  UART  signal,  module  power-on/resetting  signal,  main  antenna  interface  and power-supply interface. Figure below is the system connection structure. Figure 2-1    System Connection Structure   2.2.2  Radio Frequency Function The working frequency band of module is shown in the table below.   a) Support HSDPA/WCDMA 850(900)/1900/2100MHz.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    17    MW36500 b) Support GSM/EDGE/GPRS 850/900/1800/1900MHz. c) The highest downlink rate supported by HSDPA is 3.6Mbit/s. d) PS domain supports EDGE CLASS12/GPRS CLASS10 bearer service. e) CS domain supports 64Kbit/s data service in WCDMA mode. Table 2-3    Working Frequency Band Working Frequency Band  Uplink Frequency Band  Downlink Frequency Band UMTS850 (band V)  824 MHz — 849 MHz  869 MHz    — 894 MHz UMTS900 (band VIII)  880 MHz — 915 MHz  925 MHz    — 960 MHz UMTS1900 (band II)  1850 MHz — 1910 MHz  1930 MHz — 1990 MHz UMTS2100 (band I)  1920 MHz — 1980 MHz  2110 MHz — 2170 MHz GSM850  824 MHz — 849MHz  869 MHz — 894 MHz GSM900  890 MHz — 915MHz  925 MHz — 960MHz GSM1800  1710 MHz — 1785MHz  1805 MHz — 1880MHz GSM1900  1850 MHz — 1910MHz  1930 MHz — 1990MHz
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    18    MW36500 3 Mechanic Features 3.1  Module Illustration The Product Illustration of module is shown in the Figure 3-1.   Table 3-1    Product Illustration    NOTE:   The picture above is just for reference; please take the actual products as the reference.  Dimensions (L × W × H): 30.0 mm × 30.0mm ×2.3mm  Weight: about 5g.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    19    MW36500 3.2  Module hex-vision images The module hex-vision images are shown in figure 3-2 (units: mm).  Figure 3-2    module hex-vision images  Note: the height in the figure above is without the module label, so it is 2.2mm. 3.3  Module Main Board PCB Encapsulation Dimension Diagram The detailed dimension of PCB welding panel is shown in figure 3-3 (units: mm).
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    20    MW36500 Figure 3-3    The detailed dimension of PCB welding panel   Figure 3-4    Recommended Welding Panel Design Dimension of Customer Interface Board
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    21    MW36500  Figure 3-5    PCB Bottom Welding Panel  3.4  PCB Design Guidelines To ensure the module has good performance in the application process, the users of modules should do as the following guidelines in the process of PCB wire designing:   1) For testing and maintenance convenience, the customer dev board PCB should be hollowed out to show the test pionts as is shown in the red box in figure 3-5 so as to do JTAG installation and debugging. 2) The rest round test points are used for module power supply and calibration in SMT production process. Do not short out these test points when connect the module to main board. 3) In the design process, the strongly disturbing signals such as clock signal, high-frequency digital signal and switching signal of switch power supply should be placed far away from the module. 4) Please pay attention  to the protection  of RF  and audio analog signal. If condition permits, it  is better  to separate  the  analog ground  and  digital  ground.  After  the  separation,  the signal  line  or power line should not pass over the separation channel. 5) To ensure the integrity and circulation ability, if condition permits, it is better to adopt planar form. 6) Please ensure the integrity of the module ground to reduce the leak of disturbing signal.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    22    MW36500 3.5  Suggestions for Heat-dissipation Design The  module  will  dissipate  heat  during  the  working  process,  and  might  also  be  affected  by  other high-temperature devices. When do the heat-dissipation design, please pay attention to the following items: 1) Place this product far away from the switch power supply and high speed signal line, and protect the wiring of these interference sources. 2) Place  the  antenna  and  coaxial-cable  connecting  the  network  card  and  antenna  far  away  from  these interference sources. 3) Place  the  module  far  away  from  the  devices  that  have  high  calorific  power  such  as  CPU  and Southbridge to avoid the influencing the RF performance because of the temperature rise.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    23    MW36500 4 Interfaces 4.1  Definition of PINs The definition of interface PINs on module is shown in figure 4-1. Figure 4-1    PIN Configuration Diagram   Table 4-1    PIN Interface Definition PIN  Classification  Signal Definition  I/O  Description  Remark 1  POWER_ON  ON/OFF  I  Power on/off  Pull-up internally, low pulse active
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    24    MW36500 PIN  Classification  Signal Definition  I/O  Description  Remark 2  RESET  PON_RESET_N  I  Reset signal  1.8V low level active 3  GND  --  GND  -- 4  VREF_2V8  O  Voltage output  2.85V 5  VREF_1V8  O  Voltage output  1.8V 6  NC  --  --  -- 7  GPIO  I/O  GPIO  -- 8  GPIO  I/O  GPIO  -- 9  GND  --  GND  -- 10  NC  --  --  -- 11  GND  --  GND  -- 12 Reserved Reserved  --  --  -- 13  Reserved  --  --  -- 14  Reserved  --  --  -- 15  Reserved  --  --  -- 16  Reserved  --  --  -- 17  Reserved  --  --  -- 18  Reserved  --  --  -- 19  Reserved  --  --  -- 20  GND  --  GND  -- 21  GND  --  GND  -- 22 USB VBUS  I  USB power  5V 23  USB_DM  I/O  USB data-  -- 24  USB_DP  I/O  USB data +  -- 25  NC  --  --  -- 26  NC  --  --  -- 27  NC  --  --  -- 28  NC  --  --  -- 29  NC  --  --  -- 30  NC  --  --  -- 31  GND  --  GND  -- 32 SPI SPI_MISO_DATA  --  Main input, slave output  1.8V 33  SPI_MOSI_DATA  --  Main input, slave output  1.8V 34  SPI_CLK  I/O  SPI interface clock signal  1.8V 35  SPI_CS_N  I/O  SPI strobe signal  1.8V 36  GND  --  GND  -- 37  USIM  USIM_CLK  O  USIM card clock line  1.8V/3.0V
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    25    MW36500 PIN  Classification  Signal Definition  I/O  Description  Remark 38  USIM_DATA  I/O  USIM card data line  1.8V/3.0V 39  USIM_RST  O  USIM card reset signal  1.8V/3.0V 40  VREG_USIM  O  USIM 1.8/3V power supply    1.8V/3.0V 41  USIM_DETECT  I  USIM card detect signal  1.8V 42 Reserved Reserved  --  --  -- 43  Reserved  --  --  -- 44  Reserved  --  --  -- 45  Reserved  --  --  -- 46  GND  --  GND  -- 47  ADC  ADC2  I  ADC  0-VCC 48  ADC1  I  ADC  0-VCC 49  GND  --  GND  -- 50  V_MAIN  I  Module main power supply  3.3V-4.2V 51  V_MAIN  I  Module main power supply  3.3V-4.2V 52  GND  --  GND  -- 53 UART UART_TXD  O  UART Transmit Data  DTE receive serial data 54  UART_RXD  I  UART Receive Data  DTE transmit serial data 55  UART_RTS  O  Ready for sending  DCE Request to send 56  UART_CTS  I  Ready for receiving  -- 57  UART_DSR  O  UART DCE get ready  DCE get ready 58  UART_DTR  I  UART DTE get ready  DTE get ready 59  UART_DCD  O  UART Carrier detects   60  UART_RI  O  UART Ring Indicator Notify DTE the remote call 61  GND  --  GND  -- 62  ANT  RF_ANT  I/O  Antenna interface  -- 63  GND  --  GND  -- 64  GPIO  I/O  GPIO  --
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    26    MW36500 PIN  Classification  Signal Definition  I/O  Description  Remark 65  GPIO  I/O  GPIO  -- 66  GPIO  I/O  GPIO  -- 67  NC  --  --  -- 68  NC  --  --  -- 69  WWAN_STATE  O  Network status index signal 70  SIG_LED  O  Module status indicator light 1. Power-on status: indicator light off;   2. network searching status: indicator light flickers with the frequency of 3Hz; 3.Standyby status: indicator light flickers with the frequency of 1Hz; 4.Service status: indicator light flickers with the frequency of 5Hz. 71  WAKEUP_OUT  O  output wakeup signal  -- 72  WAKEUP_IN  I  Input wakeup signal  -- 73  I2C  I2C_SCL  I  I2C clock line  1.8V 74  I2C_SDA  I/O  I2C data line  1.8V 75  GPIO  I/O  GPIO  -- 76  GPIO  I/O  GPIO  -- 77  GPIO  I/O  GPIO  -- 78  GND  --  GND  -- 79  NC  --  --  -- 80  GND  --  GND  --   NOTE:   WAKEUP is USB wake-up PIN in default. If the main controller needs to be waked up after a trigger event (such as SMS arrive) happens, a “low-high-low” PWL change is generated and each state lasts 1s. Then the level of this pin changes to high level. Then main controller needs to issues USB wake-up command to wake up the module.  Figure 4-2    Wakeup Waveform
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    27    MW36500   4.2  Hardware interface description The  interfaces  and  peripheral  circuit  should  be  designed  reasonably  in  the  process  of  hardware development.  The interface voltages  of peripheral circuit must match with  voltages of product pins., otherwise  the  performance  may  be  influenced  or  the  module  cannot  work  normally  or  even  be damaged. This  section  mainly  describes  related  interfaces  of  the  module  including  interface  logic  function, interface description, design example and match circuit. According to the interfaces description in this section,  customers  can  make  secondary  developments  about  embedded  system  and  consumer electronics. Interfaces of MW3650 module includes as following aspects.  UART interface  (U)SIM card (compatible with 1.8V/3.0V)  USB2.0 full-speed interface  External power supply  Power on/off and RESET control  I2C interface  SPI interface  ADC  Module status indicator
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    28    MW36500 4.3  Ground GND is the Ground signal of this product, and needs to be well connected to the ground on system board. If the GND signal is not connected completely, the performance of module will be affected. Well ground handing is important to module performance guarantee such as guaranteeing signal integrity, improving RF performance, reducing EMI interference and heat dissipation. In module ground handing process: 1. The module ground welding panel should have full access to mainboard welding panel; 2. All GND pins must be accessed to ground panel with shortest ground wire. All GND pins should be connected together effectively using plenty of vias; 3. For  RF  signal,  please  pay  attention to  the  resistance  wire  structure  (micro  strip  line,  strip line)  and ensure the integrity of reference ground; 4. It is wise to surround (on both sides) the PCB transmission line such as audio and clock signal with Ground, and isolate the interference source from sensitive source; 5. Line geometry should have uniform characteristics, constant cross section, avoid meanders and abrupt curves.  4.4  Power Interface 4.4.1  V_MAIN PINS According to the definition, power supply pins of module are described as V_MAIN signal group including pin50&51. Power supply pins V_MAIN are positive poles and input signals. When design the external circuit, firstly, ensure external power supply circuit has sufficient power supply ability and the power voltage range is strictly controlled between 3.4V and 4.2V (typical value 3.8V). If the voltage is higher than the voltage range, the main chip will be damaged while if the voltage is lower than the voltage range, the working of RF circuit will be influenced or shutdown/restart phenomenon will happen. When  the  network  signal  is  weak,  RF  transmit  power  and  module  transient  current  will  increase  and transient peak current value will reach about 2A. So when design the power supply circuit, choose DC/DC
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    29    MW36500 or  LDO  of  that  lager  than  2A.  In  addition,  considering  that  the  transient  current  needed  by  high-power transmit is large under GSM model, so in the circuit design process, please add a large capability (lager than 470uF) in the output of DC/DC or LDO to avoid voltage decline abruptly. Sufficient line width of power line on  system  board  should  be  guaranteed,  and  at  the  same  time,  the  power  line  should  form  a  well circumfluence with ground panel. Moreover, in the power supply circuit design process, large capacitance at kilo uF level should  be added to guarantee the  transient power supply ability. It is recommended that  on system side DC/DC power supply is adopted and power ripple is controlled within 100mV. Table 4-2    Voltage Current Characteristic Type  Minimum value  Typical value  Maximum value (transient) Input voltage  3.3 V  3.8 V  4.2 V As is shown in the following figure, using LDO power supply circuit as a reference, over-current capability of LDO needs to be above 3A. As the poor transient response of linear regulator, large capacitors should be placed at the input and output of LDO to avoid resetting or power off resulted from that too large voltage fluctuation in high-power transmitting process under GSM mode. The reference power supply circuit design with LDO is as shown in Figure below. Figure 4-3    LDO Power Supply    As is shown in the following figure, use DC/DC switch power and large capacitors (lager than 1000uF) to ensure the normal working of RF PA (power amplifier) and sufficient transient current under GSM Burst mode. The advantage of this reference design is that it can provide well transient current under  2G weak signal environment  to  satisfy modules requirements,  to  prevent  device  shutdown  and  Ports re-enumeration  as  a consequence of the supply voltage drop. The over-current ability of DC/DC switch power should be larger than 3A such as ZI1153, AAT2138 and so on. The input voltage range of ZI1153 is 2.5V~5.5V and the output voltage range is 0.6V to VIN (input). The input voltage range is 2.7V~5.5V and the output voltage range is 3.3V~5.5V.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    30    MW36500 As  shown  in  the  Figure  below,  use  DC/DC  switching  power  supply  ZI1153  as  the  buck  chip.  Place  a tantalum  capacitor  of  330UF  at the  input  of  the chip.  Place  a  2200UF  capacitor  or  place  several  330UF tantalum capacitors in parallel. This circuit fully meets the module power requirements. (If the user’s PCB size is limited, the output of buck chip can place three more 330UF tantalum capacitors of which the total capacity is more than 1000uF) Figure 4-4    DC/DC Switching Power Supply Vin=5V Vout=3.8V 4.4.2  VREF PINS MW3650 module has 2 power output pins used to supply power for external circuit on the mainboard. The voltages of these pins and the voltages of baseband processor and storage come from the same internal voltage regulator. They output  voltage  only  when  the  module  is  powered  on.  The  normal  output  voltage  is  PIN5  (VREF_1V8,1.8V)  and PIN4(VREF_2V8,2.85V).  Users  should  draw  current  as  less  as  possible  from  these  pins.  Generally,  users  are suggested that these power pins are only used for pulling up chip pins in level matching process. 4.4.3  PCB Layout Guideline of Power Supply When design the power supply of module, the layout and wiring of related components in power supply part is very important. If they are not designed appropriately, it will have effects on many aspects, such as the EMC performance , the transmission modulation spectrum, receive sensitivity and so on. The users of Modules should do as the following guidelines in the process of power supply PCB line designing: The use of a good common ground plane is suggested.   Because the power switch has strong EMC interference, place the circuit lines far away from antenna.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    31    MW36500 Considering the module power supply requirements, the PCB traces from the input connector to the power regulator IC must be wide enough to ensure no voltage drops occur when the 2A current peaks are absorbed. The recommended power wiring width is more than 100mil. The  wiring  of  power  supply  should  be  far  away  from  the  circuit  which  is  sensitive  for  noise  such  as microphone/earphone, RF cable and so on. The PCB wiring between module and bypass capacitor should be wide enough and as short as possible to ensure there is no significant voltage decline abruptly when the current is peak 2A. 4.5  Power-on/Power-off & Reset   4.5.1  Power On   After the module been normally electrified, it is in power-off status. To turn on the module, the ON/OFF pin must be tied low for at least 3 seconds and then released.   4.5.2  Power Off To turn off the module the ON/OFF pin must be tied low for at least 3 seconds and then released.   The power on/off part circuit reference design is shown in the following figure. Figure 4-5    Power On & Reseting Circuit Reference Diagram
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    32    MW36500 4.5.3  Reset   You  can  reset  the  module  by  driving  the  PON_RESET_N  to  a  low  level  voltage  for  more  than  100ms  and  then releasing. After resetting, the module will shut down first and then enter power-on status automatically.  Other advises To ensure that the data of module is well saved a, please do not cut off the module power during the module runtime. It is strongly recommended that use AT command (+ZPWROFF) to shut down the module in application. The PON_RESET_N and ON/OFF signals are sensitive. When designing a circuit on the PCB of the main board, it is recommended that the circuit length not exceed 20 mm and the circuit be kept at a distance of 2.54 mm (100 mil) at least from the PCB edge. Furthermore, you need to surround (on both sides) the signals with Ground. Otherwise, the module may be reset due to interference. 4.5.4  Power-on/Power-off Flow To guarantee the user can power on and power off stably, you can refer to the power-on sequence chart as shown in Figure 4-6 and the power-off sequence chart as shown in Figure 4-7. Table 4-3 shows the power-on and power-off time. During the process of power on the module, pay attention to the following items:   1) The power on time that the module supplies to external interfaces cannot be earlier than the module power on time. 2) Once the V_MAIN is powered on, the ON/OFF signal will be synchronized and established as the high PWL. 3) The time interval between the V_MAIN is electrified normally and ON/OFF signal is valid could not be too short. For details see T2 parameter. It is recommended not to disconnect the power supply after V_MAIN is powered off. 4) The failing edge of ON/OFF is the start of power-on time. ON/OFF should be released after being kept at low PWL for a period of time. 5) VBUS supplies power for USB PHY. It is not recommended to connect VBUS to power supply before V_MAIN. During the process of power-off, pay attention to the following items: 1) To power off by the ON/OFF signal, the T4 period needs to be designed as required. 2) After VPH_PWR and USB_VBUS are powered off, it is recommended not to disconnect the power supply.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    33    MW36500 Figure 4-6    Power-on Sequence Chart of Module V_MAINVBUSON/OFFT1T2T3 Figure 4-7    Power-off Sequence Chart of Module ON/OFFT5T4V_MAINVBUS Table 4-3    Power-on/Power-off Time Parameter  Description  Min  Typical  Max  Unit T1  The time from power-on issue to VBUS ready  0  0.5  1  second T2  From powering on V_MAIN to ON/OFF ready  1  1.5  --  second T3  The time of active low level impulse of ON/OFF pin to power on module  --  3  --  second T4  The time of active low level impulse of ON/OFF pin to power off module  --  3  --  second T5  The time from power-off issue to V_MAIN and VBUS off  1  2  --  second
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    34    MW36500 4.6  UART Interface The module provides a series of UART interfaces. The highest speed is 230.4Kbps and the typical speed is 115.2Kbps. The external interface PWL is 1.8V CMOS PWL signal used for UART communication. The definition and interface mode of UART are shown as followed. Table 4-4    The Definition of UART Signal PIN No.  Type  Definition  I/O  Description 53 UART(1.8V) UART_TXD  O  UART Send 54  UART_RXD  I  UART Receive 55  UART_RTS  O  Send get ready   56  UART_CTS  I  Receive get ready 57  UART_DSR  O  Data equipment get ready 58  UART_DTR  I  Data terminal get ready 59  UART_DCD  O  Data carrier wave detect 60  UART_RI  O  Ring indication   NOTE: 1) When the module communicates with PC or MCU trough UART, please pay attention to the direction of TX and RX. TX and RX is named in the reference direction of module. 2) The sleep of UART is realized through UART_DTR pin. When the module needs sleep, please set this pin as high PWL while when the module needs to be waked-up, please set this pin as low PWL. 3) When there is SMS, the RI pin will generate low PWL interrupt. 4) MW3650 UART interface supports 1.8V voltage, so the external UART interface which is not 1.8V needs PWL conversion.  As  is  shown  in  the  following  figure,  audion  can  be  used  to  realize  the  PWL  conversion.  The resistance is only an example in the figure. Please recount it during designing. The diode in the figure is Schottky diode (whose forward voltage drop is 0.3V). If other diodes are chosen, please choose the one whose forward voltage drop is small to ensure the PWL of RXD_1V8 is below the low PWL input threshold when the low PWL is input.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    35    MW36500 Figure 4-8    UART Interface PWL Conversion Reference Design  Figure 4-9    Module Serial Port & AP Application Processor Module APRXDRXDTXDTXDCTSRFR CTSRFRDTRDSRDSRDTRDCDRI RIDCDGND GND To catch LOG during the software debugging process, it is recommended for users to keep this interface and reserve testing points. If the module is connected with the application processor whose PWL is 1.8V, the connection way is as shown in figure 4-9. 8-line or 2-line connection way can be adopted. The PWL of module interface is 1.8V. If it does not match with the AP interface, the PWL switching circuit is suggested to be added. MW3650 module can connected with standard RS-232-C interface through chips of 232 type. If the design is related to the interconverting between TTL PWL and EIA PWL, the NLSX5014MUTAG chip is recommended to be used. For example, when 2-line UART is  used,  the  MAX3232  chip  is  recommended  and  when  8-line  UART  is  used,  SP3238  or  MAX3238  chip  is recommended to design the interface. The connection way is shown in the following figure.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    36    MW36500 Figure 4-10    The Connection of UART and Standard RS-232-C Interface  The module support standard 8-wire UART interfaces and transfer digital signals, please isolate them from sensitive signals to avoid influencing other analog signal and RF signal. 4.7  (U)SIM Card Interface Module  baseband  processor  integrates  the  (U)SIM  card  interface  to  compliance  with  ISO  7816-3  standards,  and supports 3.0V/1.8V (U)SIM cards. The signals on SIM card interface is as shown in Table below. Table 4-5    The Definition of USIM Card Interface PIN No.  Type  Definition  I/O  Description 37 USIM USIM_CLK  O  USIM card clock line 38  USIM_DATA  I/O  USIM card data line 39  USIM_RST  O  USIM card reset signal 40  VREG_USIM  O  USIM 1.8/3V power supply Notes about designing SIM card: 1) Because the typical speed of (U)SIM card interface is about 3.25MHz, it is recommended to place (U)SIM card console close to the (U)SIM card interface, to prevent the wiring from being too long (the wiring is recommended not to be longer than 100mm) to influence the normal communication of (U)SIM signal. 2) The wiring of SIM card signal wire should be placed far away from RF wire and V_MAIN power supply line. 3) The GND of SIM card console wiring and the module GND wiring should be short and thick, meanwhile the electric potential of them should be the same. The line width of SIM_VDD and GND should be ensured not less
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    37    MW36500 than 0.5mm. The bypass circuit between VREG_USIM and SIM_GND should not be bigger than 1uF, and be placed near the SIM card console. 4) To avoid the potential interference between USIM_CLK and USIM_DATA signal, please do not place the wiring of  them  too  near,  and  USIM_CLK  and  USIM_DATA  signal  need  to  be  surrounded  by  Ground.  USIM_RST signal also needs ground protection. Add a 0.1uF or 0.22uF capacitance of 0402 encapsulation on VREG_USIM, and cascade a 0Ω resistance and parallel a 33pF capacitance with USIM_CLK, USIM_DATA and USIM_RST for the convenience of matching of latter electrical performance and to avoid the interference because of too long wiring. Besides, USIM_DATA signal should be pulled up to VREG_USIM. The pull-up resistor value is about 10K to avoid the identification problem of SIM card. 5) Besides, these four signal wires should parallel TVS to avoid electrostatic discharge. The recommended reference design circuit of ESD protection of wireless module SIM card interface is shown in the following figure. 6) The wiring related to (U)SIM card need to be put together. The wiring width of VREG_USIM is related to its length. The recommended value is 10 mil wiring width. The wiring of (U)SIM card can refer the wiring of BUS. Please pay attention to the wiring protection to avoid the interference of high-speed signal and strong reference signal of clock to (U)SIM card signal. Otherwise the restart of (U)SIM card may be caused. The ESD protection components of (U)SIM card should be placed near (U)SIM card console to avoid the electrostatic interference to module. Figure 4-11    (U)SIM Card Console Circuit Reference Design
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    38    MW36500 4.8  USB Interface MW3650 module has the high-speed USB2.0 interface. It is connected to the system board side by LCC interface, which is the path for communication between the processor on the system board side and module of which the pins are PIN23(USB_DM) and PIN24(USB_DP). The definition of USB pins is shown in table 4-6. Table 4-6    The Definition of USB PINS PIN NO.  Type  Definition  I/O  Description  Remark 22 USB VBUS  I  USB power  5V 23  USB_DM  I/O  USB data-  -- 24  USB_DP  I/O  USB data+  -- VBUS  is  the  module  USB  power  supply  pin.  The  working  current  of  USB  is  4.75V~5.25V  and  typical  value  is 5V.This power supply can supply the module with 3.8V voltage after transition by the power supply circuit mentioned in  the  previous  section.  USB_DM/USB_DP  is  differential  data  line.  During  PCB  wiring,  it  should  meets  the requirements  of differential line and surrounded by Ground. If it is too close to antenna, to avoid the influence of antenna radiation,  high-speed common mode  suppression filter can be concatenated on the USB differential signal wiring circuit. USB interface needs to add TVS components to avoid damage of module components because of static electricity. The load capacitance value of TVS should be less than 3pF, to satisfy the transmission of USB2.0 high-speed signal. In the following figure, D1 is USB2.0 anti-static protective components. Meanwhile, USB_VBUS pin is vulnerable to voltage shock which can damage the pin. It is recommended to adopt appropriate  OVP measure to  avid the  voltage higher  than 5.25V. Besides,  the power-off  leakage current  exists  on USB_VBUS.  It is suggested to add power switch on power supply branch circuit  or cascade  a resistance with the resistance value between 200kΩ and 400kΩ to reduce the leakage current when the module is powered off but does not cut off the power.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    39    MW36500 Figure 4-12    USB Interface Circuit Reference Design Schematic Diagram  Usually, USB interface of module can be enumerated to several ports, such as AT port, DIAG port, Modem port and so on. These ports are enumerated in order during the load process. For example, during the load process of module under Linux system, if the enumeration of DIAG port is ttyUSB0, the ports maps on PC are shown in the following table. Table 4-7    The Correspondence of Port Map Module  VID&PID  Dial-up port  AT Command Port  DIAG Port  Audio Port USB Modem  Service Port  Diagnostics Port  Voice Port MW3650  VID_19D2& PID_FFEB Windows: 03   /Linux: ttyUSB3 Windows: 02 /Linux: ttyUSB2 Windows: 00   /Linux: ttyUSB0 Windows: 01   /Linux: ttyUSB1 USB Modem port, bearing AT commands, is mainly used for initiating data business. Service Port, bearing AT commands, is mainly used for AT command operation when MODEM port is occupied by data business. Diagnostics Port, bearing DIAG task, can be connected to the tool for catching LOG or updating to catch software LOG information or update the firmware. 4.9  Working Status Indicator Interface The SIG_LED pin is constant current output interface whose current driver capability is 20mA. It is connected with LED to indicate the working status of module.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    40    MW36500 The indicator light reference design is shown in the following figure. The luminance of LED can be regulated by the value of resistance. The indicator status of network is as defined in table below Table 4-8    Indicator Light Reference Design Schematic Diagram  Table 4-9    The Description of Working Status Indicator Light Module status  Indicator light status  Frequency Power-on status  Indicator light off   Network searching status  Standard flicker  3Hz Free status  Slow flicker  1Hz Data business status  Fast flicker  5Hz  4.10  SPI Bus Interface The SPI interface signal definition of this product is shown in the following table. Table 4-10    The Definition of SPI Interface PIN NO.  Type  Definition  I/O  Description 32 SPI SPI_MISO_DATA  --  Main input, slave output   33  SPI_MOSI_DATA  --  Main output, slave input 34  SPI_CLK  I/O  SPI interface clock signal 35  SPI_CS_N  I/O  SPI gating signal  SPI interface electric features: The SPI bus of this product is configured as the main equipment, which has three modes: Running mode—basic running mode; Waiting  mode—  The waiting  mode  of  SPI is  a  configurable  low-power  mode,  enabled by the  byte  of  the control registered. In the waiting mode, if the waiting byte is cleared, SPI works under the similar running mode. However, if SPI waits for the position byte, SPI clock stops and enters the low-power status.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    41    MW36500 Stop mode—Under the stop mode, SPI is not available, so the power consumption is reduced. If SPI is configured as the master equipment, any transmission process will be stopped, but it can enter the running mode when the waiting mode stops.   4.11  I2C Bus I2C  is  the  two-wire  bus  for  the  communication  between  ICs,  which  supports  any  IC  process  (NMOS,  CMOS, dual-polarity). The two signal wires,  serial  data (I2C_SDA)  and serial  clock (I2C_SCL),  can transmit  information between the connected equipment. Each equipment is identified by the unique address (such as the micro controller, storage, LCD driver or keyboard interface). Due to the different functions of the equipment, it can be used as both the sender and the receiver. The I2C interface has the following electric features:   1) The two-wire bus is used for the communication between chips.   2) It supports any external equipment of any manufacturing technology (1.8V).   3) It  supports  the  external  functions,  such  as  the  image  sensor,  micro  controller,  LCD  driver  and keyboard interface.   The I2C interface has two working modes with different transmission ratios: standard mode with a speed as high as 100kbps; high-speed mode with a speed as high as 400kbps. Figure 4-11 is the I2C reference circuit design diagram. Table 4-11    I2C Reference Circuit Design
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    42    MW36500  4.12  User Interface AT commands are mainly used for communication between users and the module. AT commands comply with ITU-T V.250, 3GPP 27.007  and  3GPP  27.005  standards.  Moreover, the module also supports  ZETWelink expanding  AT commands.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    43    MW36500 5 Antenna 5.1  Preliminary Antenna Evaluation The  antenna  is  a  sensitive  device  and  its  performance  is  greatly affected  by external  environments.  The  radiation performance  of the  antenna is  affected by the mainboard  dimensions,  antenna position, occupied space size  of the antenna, and the grounding of surrounding components of the antenna. Besides, the fixed assembly of the antenna, the wiring of RF cables on the antenna, and the fixed position of the antenna all are related to the problem whether the antenna exists the interference problem with structure. Thus, during the preliminary design phase of an antenna, it is critical that antenna engineers, RF engineers, baseband engineers, structure engineers, and ID engineers work together to make estimation for both 2D and 3D design. 5.2  Antenna Design Guidance Well shielding measure should be added between external antenna and RF PAD of module, and external cables should be far away from all interference source, especially high-speed digital signal, DC/DC power and so on. According to mobile equipment standard, the standing-wave ratio of antenna the module uses should be between 1.1 and 1.5. Input resistance is 50Ω. Under different environments, the requirements of antenna gain are different. Usually, antenna performance is better if intraband gain is larger and out-of-band gain is smaller. When using the multi-ports antenna,  the isolation  between the  ports  should  be  larger than  30dB.  For example, the  isolations  between  the  two different polarization ports on polarization antenna, the two different frequency ports on dual-frequency antenna and the four ports on dual-frequency dual-polarization antenna should be larger than 30dB.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    44    MW36500 Figure 5-1    Translation Circuit Diagram Microstrip line or stripline with a natural impedance of 50 ohmMicrostrip line or stripline with a natural impedance of 50 ohmDual-L matching networkRF coaxial cable of the antennaRF interface on the antenna RF cable and RF interface on the mainboardRF interface on the moduleAntenna PIN62 is antenna pin. The following items should be noticed when this pin is used an antenna feed pin. 1) The feed  cable  connected  with  PIN  62 is  microstrip  line  or  strip  line  with  resistance  value  of  50Ω.  Near the module, π-shaped or inverted-F-shaped matching network should be added for latter tuning. 2) The RF wiring should be kept certain distance with GND. Usually the distance is 3 times the line width of RF wiring. 3) Do not pile the interference sources near the RF wiring or RF ports, such as DCDC, WIFI module and so on. 5.3  Suggested Antenna Location Mainboard area has serious interference. The experiments result shows that the module performance will be poor If the module is placed in these interference regions. During the laptop design, it is better to separate the module from the mainboard PCB, instead of installing the module on the mainboard. If they cannot be separated, the module should be far from modules and components that might generate EMI, such as chip and memory, power interface, and data cable interface.   For Internet laptops products, the ideal position of antennas is on the top left corner or top right corner of the LCD, which is relatively far from the mainboard, so the electromagnetic interference is relatively small. Besides, because it is far from human bodies, it is easy to satisfy SAR indexes. The other choice is on the left or right of LCD. Other products such as router, e-book and so on should be evaluated specifically according to the features of product itself.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    45    MW36500 Because  different  antenna  manufacturers  may adopt  different  antenna  modes  and  different  terminal  products  have different  external  dimension  and  different  requirements  for  antenna  performance,  the  reserved  spaces  as  well  as antenna  dimension  and  location  are  all  different.  Take  the  3G  internet  laptops  as  an  example,  the  recommended antenna space dimension is larger than 7mm*10mm*100mm, and it is recommended to place the antenna at the top of LCD screen. 5.4  RF PCB wire guidelines   The RF wiring of antenna should be kept as short as possible. It is suggested to choose thicker RF cables considering the transmission consumption. Meanwhile, RF cables should be far away from modules and components that might generate EMI, such as chip and memory, power interface, and data cable interface. The RF wiring connecting the antenna and 3G module should not be right angle, squeezing and abraded.   Keep, if possible, at least one layer of the PCB used only for the Ground plane; If possible, use this layer as reference Ground plane for the transmission line; 5.5  EMC Requirements Electronic communications have more EMC requirements than non-communication products. It is very important that baseband engineer, RF engineer and antenna engineer must fully communicate during the design process of circuit and wiring to reduce the electromagnetic interference of produces. The following items are common problems and solutions that can be referred during the product design process. 1) During the product design, it is better to separate the module from the mainboard PCB, instead of installing the module on the ground of the mainboard. If they cannot be separated, the module should be far from modules and components that might generate EMI, such as chip and memory, power interface, and data cable interface.   2) Because the mainboard  of PAD, CPE, and Internet laptops does not have a shielding  cover, as that of mobile terminals, to shield most  circuits  to avoid  overflow  of electromagnetic interference,  you can spray conductive paint on the surface on non-antenna areas within the structural components above and below the mainboard, and the  conductive  paint  should  be  connected  to  the  ground  on  the  mainboard  by  several  points  to  shield electromagnetic interference.   3) Besides, data cables of the LCD and the camera might introduce interference signals, which affect the receiving performance  of  the  antenna.  Thus,  it  is  necessary  to  wrap  conductive  cloth  around  the  two  data  cables  and connected them to the ground.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    46    MW36500 4) RF cables of the antenna should be far from modules and components that might generate EMI, such as chip and memory, power interface, and data cable interface. The wiring of RF cables should be close to the ground of the mainboard. 5.6  Index Requirement of Antenna Module supported electronic communications pay more and more attention to collect radiation performance test. At present  there  are  two  methods  to  investigate  the  radiation  performance:  one  method  is  investigating  the  radiation performance of antenna which is a traditional antenna test method, i.e. passive test; the other method is testing the radiation power and receiving sensitivity in a specific microwave darkroom, i.e. active test. The index requirement of antenna involves passive index requirement and active index requirement. Passive indexes include S11, antenna efficiency, antenna gain, antenna pattern and so on which can used as parameters weighing the performance of antenna itself. Active indexes usually mean OTA indexes, including TPR (all-round radiation power), TIS (all-round receiving  sensitivity),  radiation pattern  and  so  on  which  are  important indexes weighing  the whole device (including antenna, module, circuit main board) radiation performance. 5.6.1  Passive Index of Antenna Different  products  have  different  requirements  about  antenna performance.  The following  is  the  passive  reference index about PAD products while the antenna radiation performance is weighed by the active index. The passive index requirements are only for the main antenna as is shown in table below. Table 5-1    The Passive Index Reference of Main Antenna about PAD product Frequency band    824-960MHz  1710-2170MHz VSWR  <3.5:1  <3.5:1 Maximum gain  >0dBi  >0dBi Average gain  >-3.5dBi  >-3.5dBi Efficiency  >40%  >40% It is recommended that the passive index reference of diversity antenna should be decided by the requirements of its performance. If it is required that the performance of diversity antenna is the same as the performance of main antenna, the requirement about passive index of diversity antenna is shown in table above. If it is required that the performance of diversity antenna reach half of performance of main antenna, see table below for passive index.   Table 5-2    The Passive Index Reference of Diversity Antenna about PAD product Frequency band  824-960MHz  1710-2170MHz
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    47    MW36500 VSWR  <3.5:1  <3.5:1 Maximum gain  >-3dBi  >-3dBi Average gain  >-6.5dBi  >-6.5dBi Efficiency  >20%  >20%  NOTE:   MW3650 module does not support diversity reception.  5.6.2  Active Index of Antenna Active index is an important index weighing the radiation performance of whole device (including antenna, module and circuit  main  board),  so the active index decides the  final  radiation  performance  of  product.  Because  different products  have  different  active  index  and  different  operators  have  different  requirements  about  active  index,  it  is suggested  that antenna engineer,  RF engineer,  baseband  engineer,  structure engineer and  ID engineer  evaluate the performance  the  whole  device  can  achieve  according  to  the  requirements  customer  provides  about  the  product performance  in  the  beginning  of  a  project  to  decide  the  active  index.  For  mobile  terminal  product,  there  is  no international general standard. The standards are all customized according to the requirements of operator. Table 5-4 is the active index provided by our company for mobile terminal products for reference. Table 5-3    Recommended Product OTA Index Requirement   Mode  Frequency band  TRP(dBm)  TIS(dBm) Free space  Free space GSM GSM850MHz  28  -104   GSM900MHz  28  -104   GSM1800MHz  26  -102   GSM1900MHz  26  -102   WCDMA Band I  19  -106   Band II  19  -104.5   Band V  19  -104.5   Band VIII  19  -104.5 The active index reference of diversity antenna should be decided by the performance of diversity antenna.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    48    MW36500 5.6.3  OTA Test method of Whole Machine Antenna Refer to the OTA test method of corresponding products in CTIA. Figure 5-6 is the structure of OTA test system in CTIA. This system mainly consists of darkroom, high-precision location system and its controller, RF test instrument and  PC  with  automatic  test  program.  The  main  RF  instruments  involve  integrated  testing  instrument,  frequency spectrograph and network analyzer. The frequency spectrograph, swivel table controller and PC with automatic test program communicate with each other through GPIB interface. Figure 5-2    OTA Test System
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    49    MW36500 6 Electric Feature This section mainly introduces the electric features of the module, including module interface PWL, power dissipation, reliability and so on. 6.1  Interface PWL See table 6-1 for the main outward interface PWL of the module. Table 6-1    Main Out ward Interface PWL of Module Interface  PWL  Min    Typical  Max UART  0  --  0  0.1*V_UART 1  0.9*V_UART  V_UART  -- UIM  0  --  0  0.1*VREG_USIM 1  0.9*VREG_USIM  VREG_USIM  -- V_UART is 1.8V, VREG_USIM is 1.8V or 3V. Please design according to the CMOS interface PWL. 6.2  Power Supply The input voltage range of MODULE is DC 3.4V~4.2V, and the typical value is 3.8V as shown in Table6-2. Table 6-2    Input Voltage Parameter  Min  Typical  Max Input voltage    3.3V  3.8V  4.2V 6.3  Working Current The working current range of module is as shown in Table 6-3. The Sleep mode indicates the power consumption of the module in standby and sleep mode. The table also provides the working current range under GSM and WCDMA mode when there is data service.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    50    MW36500 Table 6-3    The Current Consumption under Sleep Mode Mode  Frequency Band  Test value (mA)  Remark WCDMA Band I (IMT2100)  <5 Sleep mode Band II (PCS1900)  <5 BandV(850)  <5 BandVIII(900)  <5 GSM GSM1900  <5 GSM1800  <5 GSM900  <5 GSM850  <5 Note:USB bus is fully suspended under this mode. In this mode, the module can also accept SM from the network. The power consumption is decreased to the lowest level. The above test value is the average current acquired under the maximum transmission power. Under different environments, the testing results might be slightly different. Take the actual situation as the reference. Table 6-4    The Working Current of MODULE Mode  Frequency Band  Test value (mA)  Remark UMTS  Band I (IMT2100)  540 The module in state of working. Band II (PCS1900)  530 BandV(850)  389 BandVIII(900)  537 GSM/GPRS  GSM1900  226 The module in state of working. GSM1800  169 GSM900  239 GSM850  239 Note:  The  above  test  value  is  the  average  current  acquired  under  the  maximum transmission  power.  Under  different  environments,  the  testing  results  might  be  slightly different. Take the actual situation as the reference.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    51    MW36500 7 Technical Index of Radio Frequency Test Environment: Test instrument: Agilent 8960 Power supply: Agilent 66319D RF cable length: About 15 cm WCDMA 850 MHz/900 MHz compensation: 0.6dB WCDMA 2100 MHz/1900 MHz compensation: 0.8dB  NOTE:   The compensation value is set by the frequency characteristic of corresponding RF cable. The compensation mode is related to the equipment. 7.1  Index of RF under UMTS Mode The RF index should be tested strictly in accordance with the related testing specifications of 3GPP. The RF indexes of UMTS2100/1900/850/900 should satisfy the requirements of 3GPP TS 34.121 protocol. 7.1.1  Maximum Transmission Power Maximum transmission power is another very important index to weigh the module performance. It is the maximum transmission power the module can transmit tested at the antenna port. Under the normal testing environment, the test value and reference value of the maximum transmission power of UMTS2100/1900/850/900 are shown in the table 7-1. Table 7-1    Maximum Transmission Power Operating Band  Level  3GPP Protocol Claim    Test value UMTS850  Class 3  +24dBm +1/-3dBm  23.04 UMTS900  Class 3  +24dBm +1/-3dBm  23.04 UMTS1900  Class 3  +24dBm +1/-3dBm  22.89
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    52    MW36500 UMTS2100  Class 3  +24dBm +1/-3dBm  22.45 7.1.2  Receiving Sensibility The receiving sensitivity is a key parameter  that indicates  the weakest signal strength  the  module can  receive and work well with it. At the same time the BER (Bit Error Rate) must meet the 3GPP TS 34.121protocol requirements in case of the minimum signal. The test value of UMTS2100/900 receiving sensibility is shown in the Table 7-2. Table 7-2    Reference of Receiving Sensitivity Operating Band  Unit  3GPP Protocol Claim  Test value UMTS850  dBm/3.84 MHz  ≤-103.7dBm  -109.9 UMTS900  dBm/3.84 MHz  ≤-103.7dBm  -109.2 UMTS1900  dBm/3.84 MHz  ≤-104.7dBm  -110.3 UMTS2100  dBm/3.84 MHz  ≤-106.7dBm  -109.9 7.1.3  Spurious Emission Index The spurious emission is the signals the transmitter transmits beyond the frequency band the spectrum emission mask describes.  The  spurious  emission  will  interfere  other  wireless  communication  systems.  The  aims  of  meeting  the spurious emission requirements are improving the electromagnetic compatibility performance of the system for better coexisting  of  other  systems  and ensuring the  normal  running  of  the  system itself.  The  spurious emission index of UMTS2100/1900/850(900) should comply with the requirements in 3GPP TS 34.121 protocol, as illustrated below. And the test result of module in UMTS mode meets the requirement in Table 7-3. Table 7-3    Spurious Emission Index Frequency Band  Resolution Bandwidth  Minimum Requirement 9 kHz ≤ f < 150 kHz  1 kHz  -36 dBm 150 kHz ≤ f < 30 MHz  10 kHz  -36 dBm 30 MHz ≤ f < 1000 MHz  100 kHz  -36 dBm 1 GHz ≤ f < 12.75 GHz  1 MHz  -30 dBm 7.2  Index of RF under GPRS/GSM/EDGE Mode The RF indexes of GSM/GPRS/EDGE 900/1800 should satisfy the requirements of 3GPP TS 05.05 protocol.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    53    MW36500 7.2.1  Maximum Transmission Power Maximum transmission power is another very important index to weigh the module performance. It is the maximum transmission power the module can transmit tested at the antenna port. Under the normal testing environment, the test value and reference value of the maximum transmission power of GSM850/900/1800/1900 (GMSK/8PSK) are shown in the table 7-4. Table 7-4    Maximum Transmission Power of GSM850/900/1800/1900 (GMSK/8PSK) Frequency Band  Power Level  3GPP Protocol Claim  Test value GSM850  Class 4  +33dBm±2dBm  32.61 dBm GSM900  Class 4  +33dBm±2dBm  32.9 dBm GSM1800  Class 1  +30dBm ±2dBm  30.08dBm GSM1900  Class 1  +30dBm ±2dBm  29.55 dBm 7.2.2  Receiving Sensibility The receiving sensitivity is a key parameter  that indicates  the weakest signal strength  the  module can  receive and work well with it. At the same time the BER (Bit Error Rate) must meet the 3GPP TS 34.121protocol requirements in case of the minimum signal. The test value of GSM850/900/1800/1900 (GMSK/8PSK) receiving sensibility is shown in the Table 7-5. Table 7-5    Receiving Sensitivity Frequency Band  Unit  3GPP Protocol Claim  Test value GSM850  dBm/3.84 MHz  ≤-102dBm  -110.3dBm GSM900  dBm/3.84 MHz  ≤-102dBm  -110.2 dBm GSM1800  dBm/3.84 MHz  ≤-102dBm  -108.3dBm GSM1900  dBm/3.84 MHz  ≤-102dBm  -107.3 dBm 7.2.3  Spurious Emission Index The spurious emission is the signals the transmitter transmits beyond the frequency band the spectrum emission mask describes.  The  spurious  emission  will  interfere  other  wireless  communication  systems.  The  aims  of  meeting  the spurious emission requirements are improving the electromagnetic compatibility performance of the system for better coexisting  of  other  systems  and ensuring the  normal  running  of  the  system itself.  The  spurious emission index of GSM850/900/1800/1900 (GMSK/8PSK) should comply with the requirements in 3GPP TS 34.121 protocol. And the test result of module meets the requirement in following. The test power should be less than -36dBM tested under the frequency band between 9kHz and 1GHz.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    54    MW36500 The test power should be less than -30dBm tested under the frequency between 1GHz and 12.75GHz.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    55    MW36500 8 Related Test & Test Standard 8.1  Testing Reference The  related  tests  of  MODULE  comply  with  the  IEC  standard,  including  the  equipment  running  under  high/low temperature, storage under high/low temperature, temperature shock and EMC. Table 8-1 is the list of testing standard, which includes the related testing standards for MODULE. Table 8-1    Testing Standard Test Standard  Document Reference IEC6006826  Environmental testing-Part2.6:Test FC: Sinusoidal Vibration IEC60068234  Basic environment testing procedures part2. IEC60068264  Environmental testing-part2-64: Test FH: vibration,  broadband random and guidance. IEC60068214  Environmental testing-part 2-14: Test N:change of    temperature. IEC60068229  Basic environmental testing procedures-part2: Test EB and guidance. IEC6006822  Environmental testing-part2-2:Test B:dry heat IEC6006821  Environment testing-part2-1: Test A: cold. GB/T 15844.2  MS telecommunication RF wireless phone-set environment requirement & experimental method – part 4: Strict level of experimental condition GB/T 2423.11 Basic environment experiment of electronic products-Part2:Experiment method Try Fd: Broad frequency band random vibration (General requirement) TIA/EIA 603 3.3.5  TIA Standard-part3-5:Shock Stability    NOTE:   1. IECL International Electro technical Commission;   2. GB/T: Recommended national standard.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    56    MW36500 8.2  Description of Testing Environment The working temperature range of MODULE is divided into the normal working temperature range and the extreme working temperature range. Under the normal working temperature range, the testing result of RF complies with the requirements of 3GPP specifications, and its function is normal. Under the extreme temperature range, the RF index basically complies with the 3GPP specifications, and the quality of data communication is affected to a certain extent, but its  normal  function  is  not  affected.  MODULE  has  passed  the  EMC test.  Table  8-2  is  the  requirement  for  the testing environment, and Table 8-3 lists out the instruments and devices that might be used during the test.   Table 8-2    Testing Environment Working Condition  Min Temperature  Max Temperature  Remark Normal working condition  -30°C  +75°C  All the indexes are good.   Extreme  working condition -40°C  +85°C  Some indexes become poorer.   Storage  -40°C  +85°C  Storage environment of module  Table 8-3    Testing Instrument & Device Testing Item  Instrument & Device RF test  Comprehensive testing device RF cable Tower antenna Panel antenna High/Low-temperature running & storage test High/Low-temperature experimental box Temperature shock test  Temperature shock experimental box Vibration test  Vibration console 8.3  Reliability Testing Environment The  reliability  test  includes  the  vibration  test,  high/low-temperature  running,  high/low-temperature  storage  and temperature shock experiment test. Refer to Table 8-4 for the specific parameters.   Table 8-4    Reliability Features Test Item  Test Condition  Test Standard Random vibration  Frequency range: 5-20Hz, PSD:1.0m2/s3 Frequency range: 20-200Hz, -3dB/oct 3 axis, 1 hour for each axis IEC 68-2-6
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    57    MW36500 Temperature shock  Low temperature: -40°C ±2°C   High temperature: +90°C ±2°C   Temperature changing period: less than 30s   Test duration: 2 hours Cycle: 10 IEC 68-2-14 Na High-temperature running  Normal high temperature: 75 °C Extreme high temperature: 80°C Duration: 4 hours ZTE standard Low-temperature running  Normal low temperature: -30°C Extreme low temperature: -40°C Duration: 4 hours ZTE standard High  temperature  &  high humidity Temperature: +60°C Humidity: 95% Duration: 48 hours ZTE standard High temperature storage  Temperature: 85°C Duration: 24 hours IEC 68-2-1 Ab Low temperature storage  Temperature: -40°C Duration: 24 hours IEC 68-2-2 Bb 8.4  Reliability Testing Result Table 8-5    The Temperature Testing Result Under Windless Condition Mode  Environment temperature  Voltage  Transmit power  Duration  Testing result GPRS Class 10  +25°C  (3.8±10%)V  Max  ≥1hour  Pass EDGE Class 12  +25°C  (3.8±10%)V  Max  ≥1 hour  Pass WCDMA  +25°C  (3.8±10%)V  Max  ≥1 hour  Pass Table 8-6    The High/low Temperature Running and Storage Testing Result Test Item  Test Condition & Standard  Test Content  Test result Random vibration  Refer to Table 8-4  RF test & function test  Pass Temperature shock  Refer to Table 8-4  RF test & function test  Pass Low temperature running  Refer to Table 8-4  RF test & function test  Pass High temperature running  Refer to Table 8-4  RF test & function test  Pass Extreme  low  temperature running  Refer to Table 8-4  RF test & function test  Pass Extreme  high  temperature running  Refer to Table 8-4  RF test & function test  Pass Low temperature storage  Refer to Table 8-4  RF test & function test  Pass High temperature storage  Refer to Table 8-4  RF test & function test  Pass
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    58    MW36500 8.5  ESD Characteristic Module is sensitive to ESD in the process of storage, transporting and assembling. Especially, the module is mounted on the users’ mother board, The ESD components should be placed beside the connectors which human body might touch, such as USIM card holder, audio jacks, switches and keys,  etc.  The  measured  ESD  values  of  module  at  the  normal  temperature  are  shown  as  the following table. Table 8-7    Module ESD Features Interface  Test program  Test requirements Antenna Interface  Air discharge  ±8 kV Contact discharge  ±6kV Shielding case  Air discharge  ±8 kV Contact discharge  ±6kV
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    59    MW36500 9 SMT Process and Baking Guide Now  there  are  more  and  more  products  in  our  company.  Customers  may  meet  a  lot  of  welding problems. So, we provide this SMT process and baking guide particularly for customers to ensure the first pass yield of the module on customer side. 9.1  Storage Requirements Storage conditions: temperature<40℃, relative humidity<90% (RH), 12 months weldability guaranteed under this circumstances of excellent sealing package. The Moisture sensitivity level for all modules is level 3 (Conforming to IPC/JEDEC J-STD-020). After opening the package, mount within 168 hours under the environment conditions of temperature<30℃, relative humidity<60% (RH); if it doesn’t meet the above requirements, perform the baking process. See the baking parameters in Table below: Table 9-1    Baking parameters Temperature  Baking conditions  Baking time  Remarks 125±5℃  Moisture≤60%RH  8 hours The  accumulated  baking  time  must  be less than 96 hours   45±5℃  Moisture≤5%RH  192 hours   The product’s transportation, storage and processing must conform to IPC/JEDEC J-STD-033. When in the process of PAD designing of module, refer to IPC-SM-782A and following instructions. 9.2  Module’s Position Requirements on Main board It is recommended that the thickness of green oil at the module’s position on main board should be less than 0.02mm. Do not cover with white oil or cover white oil on the green oil layer to avoid excessive thickness. As the excessive thickness may cause the module cannot be effective contact with the solder paste thus affecting the quality of welding.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    60    MW36500 Figure 9-1    Green oil and white oil at module’s position on main board   (The figure is just for reference; it doesn’t represent the actual module encapsulation) In addition, do not lay out other components within 2mm around the module’s position on main board to ensure the maintenance of the module. 9.3  Module Planeness Standard The module’s planeness is required to be 0.15mm. Measurement method: put the module on the marble plane, use the feeler gage to measure the gap width at the position of maximum warp, and do not exert force on the module during the measurement. 9.3.1  Process Routing Selection The modules are manufactured with the lead-free process and meet the ROHS requirements, therefore it’s recommended to follow the lead-free manufacturing process upon the selection of process routing for module board and main board. 9.3.2  Solder Paste Selection The solder pastes with metal particle TYPE3 and TYPE4  can fulfill the  welding  requirements. It  is accordingly recommended to use the no-clean solder paste. If the solder paste which needs cleaning is used, we cannot guarantee the components on the module board could withstand the washing of the cleaning  solvents.  This  might  cause  the  functional  problems  of  such  components  and  affect  the appearance of the module. During the printing process, make sure the solder paste’s thickness at the position of module’s PAD is within 0.18mm -0.20mm. The  white oil need be removed
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    61    MW36500 9.3.3  Design of module PAD’s steel mesh opening on main board The  thickness  of  the  steel  mesh  on  main  board  is  selected  according  to  the  encapsulation  type  of components on the main board. Pay attention to the following requirements: 1) Make sure to design the module PAD on main board according to the third item as below. 2) The thickness of steel mesh is 0.15mm or 0.18mm, but the thickness at the position of module pad can be increased to 0.18~0.20mm or the thickness of steel mesh is directly 0.18mm~0.20mm on main board. 3) Requirements on the thickness of solder paste: control the thickness between 0.15mm and 0.18mm. 4) See the LCC module PAD’s steel mesh opening in the following table: Table 9-2    LCC module PAD’s steel mesh opening Module PAD GAP (G)=Center Distance (e)-PAD width (X)  Steel mesh opening  G≥0.5mm Drill  holes  at  100% scale in the direction of width;   extend 0.3mm outward in  the  direction  of length  G<0.5mm Contract  0.05~0.1mm in  the  direction  of width; Contract  0.05~0.1mm inward  in  the direction of  length,  extend 0.5mm  outward  in  the direction of length.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    62    MW36500 Figure 9-2    Module Board’s Steel Mesh Diagram 9.3.4  Module Board’s SMT process 1) SMT Pallets: The pallets, which are suitable for SMT, have been made for most ZTE modules. If the module has provided the pallets itself and meets the SMT requirements, customers can directly use it for module SMT. Figure 9-3    Material Module Pallet    (The figure is just for reference; it doesn’t represent the actual Material Module Pallet) Otherwise, customers need make a loading tool similar to the pallet. Customers can take out the module from the packaging box, put them into the pallet according to the sequence and direction, and then start SMT. 2) Mounting Pressure: 0.1mm  0.1mm 0.5mm 0.1mm Steel mesh opening Module  PAD  on PCB
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    63    MW36500 In order to ensure a good contact between the module and the solder paste on main board, the pressure of placing the module board on main board should be 2-5N according to our experiences. Different modules have different numbers of pads, therefore the pressure selected are different. Customers can select proper pressure based on their own situations to suppress the module paste as little as possible, in order to avoid the surface tension of the solder paste melts too much to drag the module during reflow. 9.3.5  Module Soldering Reflow Curve Module soldering furnace temperature curve is: Peak value: 245+0/-5℃ ≥217℃: 30~~60S 150~200 : 60℃~~120S Temperature rise slope: <3 /S℃ Temperature drop rate:  -2~-4 /S℃ Figure 9-4    Module Furnace Temperature Curve Diagram
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    64    MW36500 Note: The test board of furnace temperature must be the main board with the module board mounted on, and there must be testing points at the position of module board. 9.3.6  Reflow method If the main board used by customers is a double-sided board, it is recommended to mount the module board at the second time. In addition, it is preferable for the main board to reflow on the mesh belt when mounting at the first time and the second time. If such failure is caused by any special reason, the fixture should be also used to make such main board reflow on the track so as to avoid the deformation of PCB during the reflow process. 9.3.7  Maintenance of defects If poor welding occurs to the module board and main board, e.g., pseudo soldering of the module board and  main  board,  the  welder  can  directly  use  the  soldering  iron  to  repair  welding  according  to  the factory’s normal welding parameters.  9.4  Module’s Baking Requirements The module must be baked prior to the second reflow. 9.4.1  Module’s Baking Environment The operators must wear dust-free finger cots and anti-static wrist strap under the lead-free and good static-resistant environment. Refer to the following environment requirements:   The product’s transportation, storage and processing must conform to IPC/JEDEC J-STD-033.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    65    MW36500 9.4.2  Baking device and operation procedure Baking device: any oven where the temperature can rise up to 125°C or above. Precautions  regarding  baking:  during  the  baking  process,  the  modules  should  be  put  in  the high-temperature resistant pallet flatly and  slightly to  avoid  the  collisions and frictions between  the modules.  During  the  baking  process,  do  not  overlay  the  modules  directly  because  it  might  cause damage to the module’s chipset. 9.4.3  Module Baking Conditions See the baking parameters in Table 9-1.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    66    MW36500 10 Safety Warnings and Notes  During the process of the module secondary development, use and repair, all the safety warnings and notes in this section should be followed. The module integrator must pass the following safety information to users and operators or integrate the information into product operating manual:    When RF devices including the module are used, the electronic devices whose shielding performance is not good may  be  interfered.  Please  keep  far  away  from  ordinary  telephones,  televisions,  radios  and  places  of  office automatic, to avoid interaction with the module.    Please  consult  the  product  manufacturer  before  the  devices  containing  the  module  is  used  beside  medical equipment such as hearing-aid, cochlear implant and heart pacemaker.    Please do not use the devices containing the module in the environment which has potential explosion hazard such as oil depot and chemical plant and which has special requirements such as hospital and airport.    Please do not expose the module to the strong sunshine to avoid being excessive heated and damaged.    The module does not have waterproof performance, so please avoid liquid entering the module. Please do not use it in the high humidity environment such as the bathroom to avoid being damaged.    Non-professionals please do not detach the module to avoid people and devices been injured or damaged.    When cleaning the module, please shut down it first and use clean antistatic fabric.   Users  have  responsibility  to  follow  the  relevant  regulations  and  specific  operating  environment  regulations  about wireless  communication  module  and  equipment.  Our  company  is  not  responsible  for  the  relevant  loss  since  the customer do not follow the rules.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    67    MW36500 Federal Communication Commission Interference Statement   This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any  interference  received,  including interference that may cause undesired operation.   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications.  However,  there  is  no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:     ●  Reorient or relocate the receiving antenna.   ●  Increase the separation between the equipment and receiver.   ●  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.     ●  Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled  environment.  This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.  This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and     users, and the maximum antenna gain allowed for use with this device is 1.6dBi.   2) The transmitter module may not be co-located with any other transmitter or antenna.
  Hardware Development Guide of Module Products  All Rights reserved, No Spreading abroad without Permission of ZTEWelink    68    MW36500  As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM  integrator  is  still  responsible  for  testing  their  end-product  for  any  additional  compliance requirements required with this module installed  IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization.  End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be  labeled  in  a  visible  area  with  the  following:  “Contains  FCC  ID:SRQ-MW3650”.  The  grantee's FCC ID can be used only when all FCC compliance requirements are met.  Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.

Navigation menu