User manual Part 2
ZXSDR R8119 Pico Remote Radio Unit Hardware Installation Version: V2.0 ZTE CORPORATION No. 55, Hi-tech Road South, ShenZhen, P.R.China Postcode: 518057 Tel: +86-755-26771900 Fax: +86-755-26770801 URL: http://support.zte.com.cn E-mail: 800@zte.com.cn LEGAL INFORMATION Copyright © 2017 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice. Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information. The ultimate right to interpret this product resides in ZTE CORPORATION. Revision History Revision No. Revision Date Revision Reason R1.3 2016-08-18 Updated Chapter 2 Device Installation. R1.2 2016-03-30 Modifed the way of description R1.1 2016–01–10 Modifed “2 Device Installation”. Add the caution: “The device does not need to be grounded.” Modifed “3 Cables”. Modified “CAT5 Ethernet cables” to “CAT5e UTP Ethernet cables”. Add the caution: “Do not use STP Ethernet cables.” R1.0 2015-09-22 First edition Serial Number: SJ-20150805085318-002 Publishing Date: 2016-08-18 (R1.3) SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Contents About This Manual ......................................................................................... I Chapter 1 Installation Interfaces ............................................................... 1-1 Chapter 2 Installing the ZXSDR R8119 ..................................................... 2-1 2.1 Installing the Device on a Pole ............................................................................ 2-1 2.2 Installing the Device on a Concrete Wall .............................................................. 2-4 2.3 Installing the Device on a Concrete Ceiling .......................................................... 2-8 2.4 Installing a Removable Ceiling ...........................................................................2-11 Chapter 3 Installing a Cable ...................................................................... 3-1 Figures............................................................................................................. I Tables ............................................................................................................ III Glossary .........................................................................................................V SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential This page intentionally left blank. II SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential About This Manual Purpose This manual describes how to install the ZXSDR R8119 Pico Remote Radio Unit. Intended Audience Installation engineers Device supervision engineers Maintenance engineers What Is in This Manual This manual contains the following chapters. Chapter 1, Installation Describes the interfaces involved in installation. Interfaces Chapter 2, Installing the Describes how to install the ZXSDR R8119. ZXSDR R8119 Chapter 3, Installing a Cable Describes how to install cables. Conventions This manual uses the following conventions. Caution: indicates a potentially hazardous situation. Failure to comply can result in moderate injury, equipment damage, or interruption of minor services. Note: provides additional information about a topic. SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential This page intentionally left blank. II SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 1 Installation Interfaces Figure 1-1 shows the external interfaces of the ZXSDR R8119. Figure 1-1 External Installation Interfaces 1. U-shape groove 2. ETH interface 3. ANT interface For a description of the interfaces, refer to Table 1-1. Table 1-1 Interface Descriptions No. External Interfaces Description U-shape grooves Mounts the ZXSDR R8119 to installation components. ETH interface RJ45 network interface, supports the PoE function, used for the ZXSDR R8119 to connect to the ETH interface of the Pbridge (a remote convergence unit) through an Ethernet cable. ANT interface Interface complete with external antenna connection 1-1 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation This page intentionally left blank. 1-2 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 For installation modes available for the ZXSDR R8119, refer to Table 2-1. Table 2-1 ZXSDR R8119 Installation Mode Installation Type Installation Mode Installing the ZXSDR R8119 against a pole 2.1 Installing the Device on a Pole Installing the ZXSDR R8119 against a wall 2.2 Installing the Device on a Concrete Wall Installing the ZXSDR R8119 against a 2.3 Installing the Device on a Concrete Ceiling ceiling 2.4 Installing a Removable Ceiling Caution! The device does not need to be grounded. Table of Contents Installing the Device on a Pole ...................................................................................2-1 Installing the Device on a Concrete Wall.....................................................................2-4 Installing the Device on a Concrete Ceiling.................................................................2-8 Installing a Removable Ceiling .................................................................................2-11 2.1 Installing the Device on a Pole This procedure describes how to install the ZXSDR R8119 against a vertical pole. The diameter of a pole is 8 to 30 mm. For the installation components, refer to the following table. Component Quantity Two-point hanging plate Overview 2-1 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Component Quantity Pole holder Vertical pole fixture M5 × 25 countersunk screw Wing nut and washer Slide-proof rubber mat Overview Steps 1. Wrap the slide-proof rubber mat around the pole, see Figure 2-1. 2-2 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 Figure 2-1 Wrapping the Slide-Proof Rubber Mat Around the Pole 2. Secure the two-point mounting plate to the L-shaped bracket with two countersunk-head screws (M5 × 25) and two wing nuts and washers, see Figure 2-2. Figure 2-2 Securing the Two-Point Mounting Plate to the L-shaped Bracket 3. Install the L-shaped bracket and the Pole holder on the pole and tighten the screws, see Figure 2-3. 2-3 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Figure 2-3 Securing the Pole Bracket to the Pole 4. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point hanging board and push the ZXSDR R8119 to the end to fix it on the two-point hanging plate, see Figure 2-4. Figure 2-4 Mounting the ZXSDR R8119 – End of Steps – 2.2 Installing the Device on a Concrete Wall This procedure describes how to install the ZXSDR R8119 against a wall. 2-4 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 Context For the installation components, refer to the following table. Component Quantity Two-point hanging plate L-shaped bracket Wing nut and washer M5 × 25 countersunk screw ST4.2 × 32 countersunk Overview self-tapping screws φ6×30 Expansion pipe Steps 1. Secure the two-point mounting plate to the horizontal mounting bracket with two countersunk-head screws (M5 × 25) and two wing nuts and washers, see Figure 2-5. 2-5 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Figure 2-5 Securing the Two-Point Mounting Plate to the L—shaped Bracket 2. On the wall, mark locations for drilling holes based on the hole positions of the L-shaped bracket, and drill four holes at the marks with an electric drill. The holes must be at least 55 mm deep, see Figure 2-6. Figure 2-6 Drilling Holes 3. Hammer the expansion tubes into the holes with a rubber hammer, see Figure 2-7. 2-6 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 Figure 2-7 Installing the Expansion Tubes 4. Secure the L-shaped bracket to the wall with four countersunk-head self-tapping screws (ST4.2 × 32), see Figure 2-8. Figure 2-8 Securing the L-shaped Bracket to the Wall 5. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point hanging plate, and push the ZXSDR R8119 to the end to fix it on the two-point hanging plate, see Figure 2-9. 2-7 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Figure 2-9 Mounting the ZXSDR R8119 – End of Steps – 2.3 Installing the Device on a Concrete Ceiling When installing the ZXSDR R8119 against a cement ceiling, ensure that the distance between the plastic shell top of the ZXSDR R8119 and the ceiling is not less than 40 mm. This requirement can be met through the wall-mount fixture between the ZXSDR R8119 and the cement ceiling. Note: For non-cement ceilings, for example, irremovable plasterboard ceiling and PVC board ceiling, you must fix a wooden bar on the ceiling. For how to install the wooden bar, refer to “Figure 2-15”. It is not allowed to fix the two-point hanging board to the ceiling by using self-tapping screws. Context For the installation components, refer to the following table. Component Quantity Two-point hanging plate Overview 2-8 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 Component Quantity Wall-mount fixture ST4.2 × 19 countersunk Overview self-tapping screws ST4.2 × 32 countersunk self-tapping screws φ6×30 Expansion pipe Steps 1. Drill holes in the ceiling. a. Make marks on the cement ceiling in accordance with the holes of the wall-mount fixture to determine the locations of the holes to be drilled. b. Use an electric hammer drill to make three holes in the cement ceiling in accordance with the marks made on the cement ceiling. The holes must be at least 35 mm deep. Note: After the holes are drilled, clear the dust by using a dust collector. 2. Hammer expansion pipes into the holes in the ceiling by using a rubber hammer, see Figure 2-10. 2-9 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Figure 2-10 Installing Expansion Pipes 3. Use two countersunk self-tapping screws (ST4.2 × 19) to fix the two-point hanging board to the wall-mount fixture, see Figure 2-11. Figure 2-11 Fixing Two-Point Hanging Plate to the Wall-Mount Fixture 4. Use three ST4.2 × 32 countersunk self-tapping screws to fix the wall-mount fixture to the expansion pipes on the ceiling (torque: 2.4 N×m), see Figure 2-12. 2-10 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 Figure 2-12 Fixing the Wall-Mount Fixture to the Ceiling 5. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point hanging plate, and push the ZXSDR R8119 to the end to fix it on the two-point hanging plate, see Figure 2-13. Figure 2-13 Mounting the ZXSDR R8119 – End of Steps – 2.4 Installing a Removable Ceiling This procedure describes how to install the ZXSDR R8119 against a removable ceiling board. 2-11 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Context For the installation components, refer to the following table. Component Quantity Two-point hanging board L-shaped bracket M5 × 25 countersunk- head Overview screw Wing nut and washer Steps 1. Remove the ceiling, mark the positions for drilling holes on the wall based the hole positions of the L-shaped bracket, see Figure 2-14. 2-12 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 2 Installing the ZXSDR R8119 Figure 2-14 Marking Holes 2. On the removed ceiling, drill two mounting holes and one network cable hole, seeFigure 2-15. Figure 2-15 Hole Template of the Removable Ceiling Board 1. Installation hole of the network cable 2. Installation hole of the two-point hanging board Caution! The network cable hole must be drilled in accordance with the size specified on the hole template. If the hole size is smaller than that of the template hole, the network cable will be stuck when the ZXSDR R8119 is dismounted. 2-13 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation 3. Secure the two-point mounting plate and the L-shaped bracket to the ceiling with two countersunk-head screws (M5 × 25) and two wing nuts and washers, see Figure 2-16. Figure 2-16 Securing the Bracket 4. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point hanging plate, and push the ZXSDR R8119 to the end to fix it on the two-point hanging plate, see Figure 2-17. Figure 2-17 Mounting the ZXSDR R8119 5. Install the ceiling board to the original location. – End of Steps – 2-14 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Chapter 3 Installing a Cable A CAT5e UTP cable is used as the Ethernet cable. For the cable overview, see Figure 3-1. Figure 3-1 CAT5e Ethernet Cable Prerequisite The Ethernet cable is as long as needed. Caution! Do not use STP Ethernet cables. The maximum length of an Ethernet cable from the ZXSDR R8119 to the Pbridge should be less than 100 m. Steps 1. Connect one end of the Ethernet cable to the ETH interface of the ZXSDR R8119, see Figure 3-2. 3-1 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential ZXSDR R8119 Hardware Installation Figure 3-2 Connecting the Ethernet Cable 2. Connect the other end of the Ethernet cable to the Ethernet electrical interface of the Pbridge, which is a remote convergence unit. Note: Bind the cable with cable ties orderly, reserve an equal distance between every two cable ties, with a proper tension and towards the same direction. Cut up extra ties smoothly and cleanly. 3. Root and bind the cable. 4. Stick a label on the cover of the ZXSDR R8119 and write information on the label to indicate the port and Pbridge that the ZXSDR R8119 is connected. For example, PB1-PORT1 indicates that the ZXSDR R8119 is connected to the first port on the first Pbridge. – End of Steps – 3-2 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Figures Figure 1-1 External Installation Interfaces ................................................................. 1-1 Figure 2-1 Wrapping the Slide-Proof Rubber Mat Around the Pole............................ 2-3 Figure 2-2 Securing the Two-Point Mounting Plate to the L-shaped Bracket ............. 2-3 Figure 2-3 Securing the Pole Bracket to the Pole ...................................................... 2-4 Figure 2-4 Mounting the ZXSDR R8119 .................................................................... 2-4 Figure 2-5 Securing the Two-Point Mounting Plate to the L—shaped Bracket ........... 2-6 Figure 2-6 Drilling Holes ........................................................................................... 2-6 Figure 2-7 Installing the Expansion Tubes................................................................. 2-7 Figure 2-8 Securing the L-shaped Bracket to the Wall............................................... 2-7 Figure 2-9 Mounting the ZXSDR R8119 .................................................................... 2-8 Figure 2-10 Installing Expansion Pipes ................................................................... 2-10 Figure 2-11 Fixing Two-Point Hanging Plate to the Wall-Mount Fixture.................... 2-10 Figure 2-12 Fixing the Wall-Mount Fixture to the Ceiling ......................................... 2-11 Figure 2-13 Mounting the ZXSDR R8119 ................................................................ 2-11 Figure 2-14 Marking Holes...................................................................................... 2-13 Figure 2-15 Hole Template of the Removable Ceiling Board ................................... 2-13 Figure 2-16 Securing the Bracket............................................................................ 2-14 Figure 2-17 Mounting the ZXSDR R8119 ................................................................ 2-14 Figure 3-1 CAT5e Ethernet Cable ............................................................................. 3-1 Figure 3-2 Connecting the Ethernet Cable ................................................................ 3-2 SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Figures This page intentionally left blank. II SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Tables Table 1-1 Interface Descriptions................................................................................ 1-1 Table 2-1 ZXSDR R8119 Installation Mode ............................................................... 2-1 III SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Tables This page intentionally left blank. IV SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential Glossary PoE SJ-20150805085318-002|2016-08-18 (R1.3) ZTE Proprietary and Confidential
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 29 Page Layout : SinglePage EPS Processor : PStill version 1.74.14 JPEG Quality : 80 Compression Level : 6 Compression Type : auto Graphics Resolution Threshold : 900 Graphics Resolution : 600 Config File : C:\Program Files (x86)\PTC\Arbortext PE\lib\standard.pdfcf Creator : Arbortext 5.4 Create Date : 2017:07:24 09:25:29+08:00 Producer : PDFlib+PDI 7.0.4 (Win32)EXIF Metadata provided by EXIF.tools