ZXSDR R8119
Pico Remote Radio Unit
Hardware Installation
Version: V2.0
ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://support.zte.com.cn
E-mail: 800@zte.com.cn
LEGAL INFORMATION
Copyright © 2017 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.
Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History
Revision No.
Revision Date
Revision Reason
R1.3
2016-08-18
Updated Chapter 2 Device Installation.
R1.2
2016-03-30
Modifed the way of description
R1.1
2016–01–10
Modifed “2 Device Installation”. Add the caution: “The device
does not need to be grounded.”
Modifed “3 Cables”. Modified “CAT5 Ethernet cables” to
“CAT5e UTP Ethernet cables”. Add the caution: “Do not use
STP Ethernet cables.”
R1.0
2015-09-22
First edition
Serial Number: SJ-20150805085318-002
Publishing Date: 2016-08-18 (R1.3)
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Contents
About This Manual ......................................................................................... I
Chapter 1 Installation Interfaces ............................................................... 1-1
Chapter 2 Installing the ZXSDR R8119 ..................................................... 2-1
2.1 Installing the Device on a Pole ............................................................................ 2-1
2.2 Installing the Device on a Concrete Wall .............................................................. 2-4
2.3 Installing the Device on a Concrete Ceiling .......................................................... 2-8
2.4 Installing a Removable Ceiling ...........................................................................2-11
Chapter 3 Installing a Cable ...................................................................... 3-1
Figures............................................................................................................. I
Tables ............................................................................................................ III
Glossary .........................................................................................................V
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
This page intentionally left blank.
II
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
About This Manual
Purpose
This manual describes how to install the ZXSDR R8119 Pico Remote Radio Unit.
Intended Audience
Installation engineers
Device supervision engineers
Maintenance engineers
What Is in This Manual
This manual contains the following chapters.
Chapter 1, Installation
Describes the interfaces involved in installation.
Interfaces
Chapter 2, Installing the
Describes how to install the ZXSDR R8119.
ZXSDR R8119
Chapter 3, Installing a Cable
Describes how to install cables.
Conventions
This manual uses the following conventions.
Caution: indicates a potentially hazardous situation. Failure to comply
can result in moderate injury, equipment damage, or interruption of
minor services.
Note: provides additional information about a topic.
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
This page intentionally left blank.
II
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 1
Installation Interfaces
Figure 1-1 shows the external interfaces of the ZXSDR R8119.
Figure 1-1 External Installation Interfaces
1. U-shape groove
2. ETH interface
3. ANT interface
For a description of the interfaces, refer to Table 1-1.
Table 1-1 Interface Descriptions
No.
External Interfaces
Description
U-shape grooves
Mounts the ZXSDR R8119 to installation components.
ETH interface
RJ45 network interface, supports the PoE function, used for the
ZXSDR R8119 to connect to the ETH interface of the Pbridge (a
remote convergence unit) through an Ethernet cable.
ANT interface
Interface complete with external antenna connection
1-1
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
This page intentionally left blank.
1-2
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2
Installing the ZXSDR R8119
For installation modes available for the ZXSDR R8119, refer to Table 2-1.
Table 2-1 ZXSDR R8119 Installation Mode
Installation Type
Installation Mode
Installing the ZXSDR R8119 against a pole
2.1 Installing the Device on a Pole
Installing the ZXSDR R8119 against a wall
2.2 Installing the Device on a Concrete Wall
Installing the ZXSDR R8119 against a
2.3 Installing the Device on a Concrete Ceiling
ceiling
2.4 Installing a Removable Ceiling
Caution!
The device does not need to be grounded.
Table of Contents
Installing the Device on a Pole ...................................................................................2-1
Installing the Device on a Concrete Wall.....................................................................2-4
Installing the Device on a Concrete Ceiling.................................................................2-8
Installing a Removable Ceiling .................................................................................2-11
2.1 Installing the Device on a Pole
This procedure describes how to install the ZXSDR R8119 against a vertical pole. The
diameter of a pole is 8 to 30 mm.
For the installation components, refer to the following table.
Component
Quantity
Two-point hanging plate
Overview
2-1
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Component
Quantity
Pole holder
Vertical pole fixture
M5 × 25 countersunk screw
Wing nut and washer
Slide-proof rubber mat
Overview
Steps
1. Wrap the slide-proof rubber mat around the pole, see Figure 2-1.
2-2
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2 Installing the ZXSDR R8119
Figure 2-1 Wrapping the Slide-Proof Rubber Mat Around the Pole
2. Secure the two-point mounting plate to the L-shaped bracket with two
countersunk-head screws (M5 × 25) and two wing nuts and washers, see Figure 2-2.
Figure 2-2 Securing the Two-Point Mounting Plate to the L-shaped Bracket
3. Install the L-shaped bracket and the Pole holder on the pole and tighten the screws,
see Figure 2-3.
2-3
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Figure 2-3 Securing the Pole Bracket to the Pole
4. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point
hanging board and push the ZXSDR R8119 to the end to fix it on the two-point hanging
plate, see Figure 2-4.
Figure 2-4 Mounting the ZXSDR R8119
– End of Steps –
2.2 Installing the Device on a Concrete Wall
This procedure describes how to install the ZXSDR R8119 against a wall.
2-4
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2 Installing the ZXSDR R8119
Context
For the installation components, refer to the following table.
Component
Quantity
Two-point hanging plate
L-shaped bracket
Wing nut and washer
M5 × 25 countersunk screw
ST4.2 × 32 countersunk
Overview
self-tapping screws
φ6×30 Expansion pipe
Steps
1. Secure the two-point mounting plate to the horizontal mounting bracket with two
countersunk-head screws (M5 × 25) and two wing nuts and washers, see Figure 2-5.
2-5
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Figure 2-5 Securing the Two-Point Mounting Plate to the L—shaped Bracket
2. On the wall, mark locations for drilling holes based on the hole positions of the
L-shaped bracket, and drill four holes at the marks with an electric drill. The holes
must be at least 55 mm deep, see Figure 2-6.
Figure 2-6 Drilling Holes
3. Hammer the expansion tubes into the holes with a rubber hammer, see Figure 2-7.
2-6
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2 Installing the ZXSDR R8119
Figure 2-7 Installing the Expansion Tubes
4. Secure the L-shaped bracket to the wall with four countersunk-head self-tapping
screws (ST4.2 × 32), see Figure 2-8.
Figure 2-8 Securing the L-shaped Bracket to the Wall
5. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point
hanging plate, and push the ZXSDR R8119 to the end to fix it on the two-point hanging
plate, see Figure 2-9.
2-7
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Figure 2-9 Mounting the ZXSDR R8119
– End of Steps –
2.3 Installing the Device on a Concrete Ceiling
When installing the ZXSDR R8119 against a cement ceiling, ensure that the distance
between the plastic shell top of the ZXSDR R8119 and the ceiling is not less than 40 mm.
This requirement can be met through the wall-mount fixture between the ZXSDR R8119
and the cement ceiling.
Note:
For non-cement ceilings, for example, irremovable plasterboard ceiling and PVC board
ceiling, you must fix a wooden bar on the ceiling. For how to install the wooden bar, refer
to “Figure 2-15”. It is not allowed to fix the two-point hanging board to the ceiling by using
self-tapping screws.
Context
For the installation components, refer to the following table.
Component
Quantity
Two-point hanging plate
Overview
2-8
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2 Installing the ZXSDR R8119
Component
Quantity
Wall-mount fixture
ST4.2 × 19 countersunk
Overview
self-tapping screws
ST4.2 × 32 countersunk
self-tapping screws
φ6×30 Expansion pipe
Steps
1. Drill holes in the ceiling.
a. Make marks on the cement ceiling in accordance with the holes of the wall-mount
fixture to determine the locations of the holes to be drilled.
b. Use an electric hammer drill to make three holes in the cement ceiling in
accordance with the marks made on the cement ceiling. The holes must be at
least 35 mm deep.
Note:
After the holes are drilled, clear the dust by using a dust collector.
2. Hammer expansion pipes into the holes in the ceiling by using a rubber hammer, see
Figure 2-10.
2-9
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Figure 2-10 Installing Expansion Pipes
3. Use two countersunk self-tapping screws (ST4.2 × 19) to fix the two-point hanging
board to the wall-mount fixture, see Figure 2-11.
Figure 2-11 Fixing Two-Point Hanging Plate to the Wall-Mount Fixture
4. Use three ST4.2 × 32 countersunk self-tapping screws to fix the wall-mount fixture to
the expansion pipes on the ceiling (torque: 2.4 N×m), see Figure 2-12.
2-10
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2 Installing the ZXSDR R8119
Figure 2-12 Fixing the Wall-Mount Fixture to the Ceiling
5. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point
hanging plate, and push the ZXSDR R8119 to the end to fix it on the two-point hanging
plate, see Figure 2-13.
Figure 2-13 Mounting the ZXSDR R8119
– End of Steps –
2.4 Installing a Removable Ceiling
This procedure describes how to install the ZXSDR R8119 against a removable ceiling
board.
2-11
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Context
For the installation components, refer to the following table.
Component
Quantity
Two-point hanging board
L-shaped bracket
M5 × 25 countersunk- head
Overview
screw
Wing nut and washer
Steps
1. Remove the ceiling, mark the positions for drilling holes on the wall based the hole
positions of the L-shaped bracket, see Figure 2-14.
2-12
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 2 Installing the ZXSDR R8119
Figure 2-14 Marking Holes
2. On the removed ceiling, drill two mounting holes and one network cable hole,
seeFigure 2-15.
Figure 2-15 Hole Template of the Removable Ceiling Board
1. Installation hole of the
network cable
2. Installation hole of
the two-point hanging
board
Caution!
The network cable hole must be drilled in accordance with the size specified on the
hole template. If the hole size is smaller than that of the template hole, the network
cable will be stuck when the ZXSDR R8119 is dismounted.
2-13
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
3. Secure the two-point mounting plate and the L-shaped bracket to the ceiling with two
countersunk-head screws (M5 × 25) and two wing nuts and washers, see Figure 2-16.
Figure 2-16 Securing the Bracket
4. Align the two U-shape grooves of the ZXSDR R8119 with the two rivets on the two-point
hanging plate, and push the ZXSDR R8119 to the end to fix it on the two-point hanging
plate, see Figure 2-17.
Figure 2-17 Mounting the ZXSDR R8119
5. Install the ceiling board to the original location.
– End of Steps –
2-14
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Chapter 3
Installing a Cable
A CAT5e UTP cable is used as the Ethernet cable. For the cable overview, see Figure 3-1.
Figure 3-1 CAT5e Ethernet Cable
Prerequisite
The Ethernet cable is as long as needed.
Caution!
Do not use STP Ethernet cables.
The maximum length of an Ethernet cable from the ZXSDR R8119 to the Pbridge
should be less than 100 m.
Steps
1. Connect one end of the Ethernet cable to the ETH interface of the ZXSDR R8119, see
Figure 3-2.
3-1
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
ZXSDR R8119 Hardware Installation
Figure 3-2 Connecting the Ethernet Cable
2. Connect the other end of the Ethernet cable to the Ethernet electrical interface of the
Pbridge, which is a remote convergence unit.
Note:
Bind the cable with cable ties orderly, reserve an equal distance between every two
cable ties, with a proper tension and towards the same direction. Cut up extra ties
smoothly and cleanly.
3. Root and bind the cable.
4. Stick a label on the cover of the ZXSDR R8119 and write information on the label to
indicate the port and Pbridge that the ZXSDR R8119 is connected.
For example, PB1-PORT1 indicates that the ZXSDR R8119 is connected to the first
port on the first Pbridge.
– End of Steps –
3-2
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Figures
Figure 1-1 External Installation Interfaces ................................................................. 1-1
Figure 2-1 Wrapping the Slide-Proof Rubber Mat Around the Pole............................ 2-3
Figure 2-2 Securing the Two-Point Mounting Plate to the L-shaped Bracket ............. 2-3
Figure 2-3 Securing the Pole Bracket to the Pole ...................................................... 2-4
Figure 2-4 Mounting the ZXSDR R8119 .................................................................... 2-4
Figure 2-5 Securing the Two-Point Mounting Plate to the L—shaped Bracket ........... 2-6
Figure 2-6 Drilling Holes ........................................................................................... 2-6
Figure 2-7 Installing the Expansion Tubes................................................................. 2-7
Figure 2-8 Securing the L-shaped Bracket to the Wall............................................... 2-7
Figure 2-9 Mounting the ZXSDR R8119 .................................................................... 2-8
Figure 2-10 Installing Expansion Pipes ................................................................... 2-10
Figure 2-11 Fixing Two-Point Hanging Plate to the Wall-Mount Fixture.................... 2-10
Figure 2-12 Fixing the Wall-Mount Fixture to the Ceiling ......................................... 2-11
Figure 2-13 Mounting the ZXSDR R8119 ................................................................ 2-11
Figure 2-14 Marking Holes...................................................................................... 2-13
Figure 2-15 Hole Template of the Removable Ceiling Board ................................... 2-13
Figure 2-16 Securing the Bracket............................................................................ 2-14
Figure 2-17 Mounting the ZXSDR R8119 ................................................................ 2-14
Figure 3-1 CAT5e Ethernet Cable ............................................................................. 3-1
Figure 3-2 Connecting the Ethernet Cable ................................................................ 3-2
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Figures
This page intentionally left blank.
II
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Tables
Table 1-1 Interface Descriptions................................................................................ 1-1
Table 2-1 ZXSDR R8119 Installation Mode ............................................................... 2-1
III
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Tables
This page intentionally left blank.
IV
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential
Glossary
PoE
SJ-20150805085318-002|2016-08-18 (R1.3)
ZTE Proprietary and Confidential

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 29
Page Layout                     : SinglePage
EPS Processor                   : PStill version 1.74.14
JPEG Quality                    : 80
Compression Level               : 6
Compression Type                : auto
Graphics Resolution Threshold   : 900
Graphics Resolution             : 600
Config File                     : C:\Program Files (x86)\PTC\Arbortext PE\lib\standard.pdfcf
Creator                         : Arbortext 5.4
Create Date                     : 2017:07:24 09:25:29+08:00
Producer                        : PDFlib+PDI 7.0.4 (Win32)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q78-R8119F851719A

Navigation menu