ZTE R8882L718 LTE Remote Radio Unit User Manual Users manual
ZTE Corporation LTE Remote Radio Unit Users manual
ZTE >
Users manual
ZXSDR R8882 L200 LTE Remote Radio Frequency Unit User Manual Version: V2.00 ZTE CORPORATION No. 55, Hi-tech Road South, ShenZhen, P.R.China Postcode: 518057 Tel: +86-755-26771900 Fax: +86-755-26770801 URL: http://support.zte.com.cn E-mail: support@zte.com.cn LEGAL INFORMATION Copyright © 2014 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice. Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information. The ultimate right to interpret this product resides in ZTE CORPORATION. Revision History Revision No. Revision Date Revision Reason R1.0 2011–01–19 First Edition Serial Number: SJ-20110104194923-001 Publishing Date: 2011-01-19(R1.0) SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Contents About This Manual ......................................................................................... I Chapter 1 FCC Statement .......................................................................... 1-1 Chapter 2 Product Overview ..................................................................... 2-1 2.1 Distributed eNodeB Solution ............................................................................... 2-1 2.2 Product Position in Network ................................................................................ 2-3 2.3 Product Features................................................................................................ 2-4 2.4 Product Functions .............................................................................................. 2-4 2.5 Product Appearance........................................................................................... 2-4 2.6 Installation Scenario ........................................................................................... 2-5 2.7 Product Networking ............................................................................................ 2-5 2.8 Operation and Maintenance Introduction.............................................................. 2-6 2.9 Product External Interfaces ................................................................................. 2-7 2.10 Product Indicators ............................................................................................ 2-9 Chapter 3 Product Technical Specifications............................................ 3-1 3.1 Physical Indices ................................................................................................. 3-1 3.2 Working Environment ......................................................................................... 3-1 3.3 Bandwidth.......................................................................................................... 3-2 3.4 Power Requirements .......................................................................................... 3-2 3.5 Power Consumption ........................................................................................... 3-2 3.6 Transmission Index ............................................................................................ 3-2 3.7 Performance Indices........................................................................................... 3-2 3.8 Electromagnetic Compatibility ............................................................................. 3-3 3.9 Reliability ........................................................................................................... 3-5 Chapter 4 Product Installation .................................................................. 4-1 4.1 Safety Description .............................................................................................. 4-1 4.1.1 Safety Specifications Introduction .............................................................. 4-1 4.1.2 Safety Symbols ........................................................................................ 4-1 4.1.3 Safety Operation Guidance ....................................................................... 4-3 4.2 Device Unpacking and Inspection........................................................................ 4-5 4.2.1 Unpacking and Checking ZXSDR R8882 L200........................................... 4-5 4.2.2 Goods Handover ...................................................................................... 4-6 4.3 Device Installation .............................................................................................. 4-6 4.3.1 Mounting Device on Wall .......................................................................... 4-6 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential 4.3.2 Mounting Device on Pole ........................................................................ 4-10 4.3.3 Mounting Device on Gantry..................................................................... 4-19 4.4 Cables Connection ........................................................................................... 4-23 4.4.1 Connection of External Cables ................................................................ 4-23 4.4.2 External Cable Installation Flow .............................................................. 4-24 4.4.3 Connecting Power Cable ........................................................................ 4-25 4.4.4 Connecting Grounding Cable .................................................................. 4-28 4.4.5 Connecting Fiber Between eBBU and eRRU............................................ 4-30 4.4.6 Connecting Environment Monitor Cable ................................................... 4-32 4.4.7 Connecting AISG Control Cable .............................................................. 4-33 4.4.8 Connecting the RF Jumpers.................................................................... 4-34 Figures............................................................................................................. I Tables ............................................................................................................ III Glossary .........................................................................................................V II SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential About This Manual Purpose This manual gives introduction on the product description, technical indices, and product installation. Intended Audience Hardware Installation Engineer Operation and Maintenance Engineer Prerequisite Skill and Knowledge To use this document effectively, users should have a general understanding of wireless telecommunications technology. Familiarity with LTE wireless network and its related components is helpful. What is in This Manual Chapter Summary Chapter 1, FCC Statement Introduces the FCC statements that this device complies with Chapter 2, Product Overview Describes product characteristic, interfaces, indicators Chapter 3, Product Technical Indices Describes the technical indices of the product Chapter 4, Product Installation Describes installation and cable connection of the product SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential This page intentionally left blank. II SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 1 FCC Statement FCC & IC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Caution! Changes or modifications to this unit not expressly approved by the party responsible for compliance will void the user’s authority to operate the equipment. Any change to the equipment will void FCC and IC grant. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 6.24 m between the radiator & your body. 1-1 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual This page intentionally left blank. 1-2 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 2 Product Overview Table of Contents Distributed eNodeB Solution.......................................................................................2-1 Product Position in Network........................................................................................2-3 Product Features........................................................................................................2-4 Product Functions ......................................................................................................2-4 Product Appearance...................................................................................................2-4 Installation Scenario ...................................................................................................2-5 Product Networking ....................................................................................................2-5 Operation and Maintenance Introduction ....................................................................2-6 Product External Interfaces ........................................................................................2-7 Product Indicators ......................................................................................................2-9 2.1 Distributed eNodeB Solution To supply customers with more competitive communication equipment and solution in the market, ZTE develops and promotes ZTE SDR eBBU (baseband unit) and eRRU (remote radio unit) distributed eNodeB solution timely, which jointly perform LTE eNodeB service. ZTE distributed eNodeB solution is shown in Figure 2-1. 2-1 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 2-1 ZTE Distributed eNodeB Solution ZTE's LTE eBBU+eRRU distributed eNodeB solution has the following predominance: 1. Saving labor cost and engineering cost for networking. eBBU+eRRU distributed eNodeB equipment is small in size, light in weight, and easy for transportation and engineering construction. 2. Fast networking, also saving the fees of renting equipment room. eBBU+eRRU distributed eNodeB is applicable to various sites, such as mounted on steel tower, on building top, or on wall, etc. It's more flexible in selecting installation site, and not restricted by the space of equipment room. It can help operators to deploy network rapidly. It can also save the fees of renting equipment room, and the network operation cost. 3. Convenient in upgrade and capacity expansion; saving the initial stage cost of the network. eRRU can be mounted as close to antenna as possible, to save the cost of feed cable and decrease the loss of feed cable. It also can enhance the output power of eRRU and increase the coverage. 4. Low power consumption, power-saving. 2-2 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 2 Product Overview Compared with traditional eNodeB, eBBU+eRRU distributed eNodeB has lower power consumption, which can greatly reduce the investment and cost on electric power, and thus save the network operation cost. 5. Distributed networking, making good use of operators' network resources supporting eBBU+eRRU distributed networking; supporting star networking mode between eBBU and eRRU. 6. Adopting a more perspective and generalized eNodeB platform. eBBU adopts the platform designed for the future B3G and 4G. One hardware platform can realize different standard modes, and several standard modes can coexist in one eNodeB. In this way, operators' management can be simplified, and several eNodeBs to be invested can be integrated into one eNodeB (multimode eNodeB). The operators can select the evolution direction of the future network more flexibly. 2.2 Product Position in Network ZXSDR R8882 L200 is a remote radio unit (eRRU) of distributed eNodeB. The signal is transmitted or received through ZXSDR R8882 L200 to and from base band processing unit for further processing through CPRI interface. By applying the distributed system, the feeder loss will be reduced when the remote radio unit is positioned close to the antenna. The coverage is enlarged with this solution. Figure 2-2 Product Location Note: ZXSDR R8882 L200 covers R8882 L188, R8882 L708, R8882 L808, R8882 L268 and R8882 L718. 2-3 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual 2.3 Product Features Multi-Mode eRRU ZXSDR R8882 L200 is fully software defined device. It supports multi-mode at the same frequency band simultaneously. Therefore, it fully satisfies operators’ requirements of hybrid network deployment and long term evolution with the lowest cost. MIMO Supported, Better Performance R8882 L268 supports 2T4R (license needed), R8882 L188, R8882 L708, R8882 L808 and R8882 L718 support 2T2R, which can optimize spectrum efficiency greatly and improve network uplink performance. As a result, it brings better customer experience. Higher Efficiency, Lower TCO ZXSDR R8882 L200’s PA efficiency can reach up to 30% thanks to the most advanced Doherty PA, DPD linear technology. It supports dynamic adaptive PA power supply due to the output power, which reduces power consumption. 2.4 Product Functions ZXSDR R8882 L200 is the remote radio unit of distributed base station. The signal is transmitted or received through ZXSDR R8882 L200 to/from base band processing unit for further processing via standard CPRI interface. The product basic functions are listed below: Supports the configuration of 5 MHz, 10 MHz, 15 MHz and 20 MHz scalable bandwidth. Supports 2x2 MIMO on downlink. Supports QPSK,16-QAM,64-QAM on downlink, QPSK and 16–QAM on uplink. Supports transmission and receive power detection. Supports overload power protection for power amplifier. Supports power amplifier switching on/off function. ZXSDR R8882 L200 software failure will not affect the running of eBBU and other ZXSDR R8882 L200s which are connected to it. Supports field strength scanning, temperature query, VSWR query, dry contact, hardware/software resetting. 2.5 Product Appearance The appearance of ZXSDR R8882 L200 is as shown in Figure 2-3. 2-4 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 2 Product Overview Figure 2-3 Product Overall Appearance 2.6 Installation Scenario The ZXSDR R8882 L200 usually installed on wall or on pole or on gantry. 2.7 Product Networking ZXSDR R8882 L200 supports star networking mode with eBBU, as shown in Figure 2-4. 2-5 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 2-4 Star Networking Mode 2.8 Operation and Maintenance Introduction ZXSDR R8882 L200 supports system operation and maintenance remotely or locally. Operate and Maintain System Remotely Remotely operates and maintains system by using NetNumen management system, as shown in Figure 2-5. Figure 2-5 Operate and Maintain System Remotely 2-6 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 2 Product Overview Operate and Maintain System Locally locally operates and maintains system by using ZTE’s Local Maintenance Terminal (LMT) software kit, as shown in Figure 2-6. Figure 2-6 Operate and Maintain System Locally 2.9 Product External Interfaces The ZXSDR R8882 L200 external interfaces are shown in Figure 2-7 and Figure 2-8. Figure 2-7 Product External Interfaces and Grounding Terminal 2-7 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 2-8 LMT Interface Table 2-1 shows the detailed description of all the external interfaces. Table 2-1 Product External Interfaces Description No. Label Interface/Terminal Interface type/connector PWR Power interface/1 dry contact DC interface: Connector XCG18T4K1P101+XC18FJJP1-10.5 Section area of cable is 1.5 mm2 MON 485 Serial /2 dry contacts 8-cores socket (IEC 60130-9-ED) AISG AISG device interface 8-cores aviation socket OPT1 eBBU Interface LC type optical interface OPT2 Reserved LC type optical interface ANT4(TX1/RX1) Antenna TX/RX interface on channel 1 50 Ohm DIN-7/16 Connector ANT3(RX3) Antenna RX interface on channel 3 50 Ohm DIN-7/16 Connector Grounding Terminal ANT2(RX2) Antenna RX interface on channel 2 50 Ohm DIN-7/16 Connector 10 ANT1(TX0/RX0) Antenna TX/RX interface on channel 0 50 Ohm DIN-7/16 Connector 11 LMT Operation and Maintenance Interface 8P8C Ethernet interface 2-8 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 2 Product Overview Note: There are no ANT2 and ANT3 interfaces for L708 and L808. 2.10 Product Indicators ZXSDR R8882 L200 provides six LED indicators, which are located at the right bottom side of the device. The LED indicators are used to show product working status and alarm status, as shown in Figure 2-9. Figure 2-9 Product Indicators Table 2-2 shows the detailed information of the indicators. Table 2-2 Product Indicator Description Name Color Meaning Working Mode RUN Green Running status Blinking every 1.5 second: physical link in the process of initialization Blinking every 0.07 second: the link between eBBU and eRRU is in the process of establishment, or the link is broken Blinking every 0.3 second: device is in good state 2-9 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Name Color Meaning Working Mode ALM Red Alarm indicator Solid ON: there is alarm OFF: there is no alarm Solid ON: physical link is good, logical link is OPT1 Green Optical interface running indicator abnormal OFF: physical link is abnormal Blinking every 0.3 second: interface is in good state OPT2 Green Optical interface running indicator Solid ON: physical link is good, logical link is abnormal OFF: physical link is abnormal Blinking every 0.3 second: interface is in good state VSWR1 Red Transmission Solid ON: there are VSWR alarms channel 1 VSWR OFF: there is no VSWR alarm Transmission Solid ON: there are VSWR alarms channel 4 VSWR OFF: there is no VSWR alarm indicator VSWR2 Red indicator 2-10 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 3 Product Technical Specifications Table of Contents Physical Indices .........................................................................................................3-1 Working Environment .................................................................................................3-1 Bandwidth ..................................................................................................................3-2 Power Requirements..................................................................................................3-2 Power Consumption ...................................................................................................3-2 Transmission Index ....................................................................................................3-2 Performance Indices ..................................................................................................3-2 Electromagnetic Compatibility ....................................................................................3-3 Reliability....................................................................................................................3-5 3.1 Physical Indices Item Index Dimension 380 mm x 320 mm x 140 mm (HxWxD) Weight 20 kg 3.2 Working Environment Item Working Storage Index Temperature -40℃~55℃ Relative Humidity 5%~100% Temperature -55℃~70℃ Relative Humidity 5%~98% Ground ≤5 Ω, earth resistance can be less than 10 Ω in thunder-less area where thunderstorm days is less than 20 days per year Waterproof/Dustproof IP65 3-1 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual 3.3 Bandwidth ZXSDR R8882 L200 supports 5 MHz, 10 MHz, 15 MHz and 20 MHz. Note: L708 does not support 20 MHz. 3.4 Power Requirements The power supply of the ZXSDR R8882 L200 is -48 VDC (range: -37 VDC ~-57 VDC). 3.5 Power Consumption The maximum power consumption of ZXSDR R8882 L200 is 330 W. 3.6 Transmission Index ZXSDR R8882 L200 connects to eBBU through CPRI interfaces. The detailed information of the CPRI interface is shown in Table 3-1. Table 3-1 CPRI Interface Index Item CPRI interface Quantity Interface type SFP (LC) Speed 2x3.072 Gbps or Standard CPRI V4.1 2x2.4576 Gbps 3.7 Performance Indices Operation Frequency Band R8882 L188: 1730 MHz~1785 MHz(uplink)/1825 MHz~1880 MHz(downlink) or 1710 MHz~1765 MHz(uplink)/1805 MHz~1860 MHz(downlink) R8882 L268: 2500 MHz~2570 MHz(uplink)/2620 MHz~2690 MHz(downlink) R8882 L708: 698 MHz~716 MHz(uplink)/728 MHz~746 MHz(downlink) R8882 L808: 832 MHz~862 MHz(uplink)/791 MHz~821 MHz(downlink) R8882 L718: 777 MHz~798 MHz(uplink)/746 MHz~768 MHz(downlink) Output Power R8882 L188, R8882 L708, R8882 L808, R8882 L718: 2x40 W R8882 L268: 2x30 W 3-2 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 3 Product Technical Specifications Receiver Sensitivity The receiver sensitivity of ZXSDR R8882 L200 is shown in Table 3-2. Table 3-2 Receiver Sensitivity Channel bandwidth (MHz) 5/10/15/20 Reference measurement Reference sensitivity power channel level (dBm) FRC A1-3 -104 Transmission The maximum transmission distance is 10 kilometers. Supports two kinds of optical fiber interface mode: 2x3.072 Gbps and 2x2.4576 Gbps. 3.8 Electromagnetic Compatibility The decision rule used in this section is describes as follows: 1. Rule A l A communication channel is set up for the test, and it is always available during the test. l FER of the forward channel and reverse channel are less than or equal to 1 during the test. l When the test task accomplished, equipment under test (EUT) works normally under pre-scheduled method, there is no information loss of user control function and the saved data, and the communication channel is still available. l If the EUT is a transmitter only, test should be done under idle-mode, and there is no unintentional radiation during the test. 2. Rule B l A communication channel is set up for the test, and it is always available during test. l EUT works normally under pre-scheduled method, there is no information loss of user control function and the saved data, and the communication channel is still available. l If the EUT is a transmitter only, test should be done under idle-mode, and there is no unintentional radiation during the test. 3. Rule R There is no device damage or interference (such as software malfunction or protection device mis-operation) during the test. The EUT works normally under the defined boundary after transient electromagnetic incident. Electronic Static Discharge Immunity Item Contact discharge Air discharge Decision Rule Basic testing 6 kV 8 kV Rule B Enhanced testing 8 kV 15 kV Rule R 3-3 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual RF Electromagnetic Field Radiation Immunity Range Feature Field Strength Decision Rule 80 MHz~800MHz 80%AM(1kHz) 10 V/m Rule A 800 MHz~960 MHz 80%AM(1kHz) 10 V/m Rule A 960 MHz~1400MHz 80%AM(1kHz) 10 V/m Rule A 1400 MHz~2700 MHz 80%AM(1kHz) 10 V/m Rule A 2700 MHz~6000 MHz 80%AM(1kHz) 10 V/m Rule A Electrical Fast Transient Burst Immunity Item Voltage Repetition Frequency Decision Rule Basic test ±1 kV 5 kHz Rule B Enhanced test ±2 kV 5 kHz Rule B signal generator waveform 5/50ns Lightning Tolerance Signal Type Nominal Required Antenna feeder port 10 kA ± 5 times The 10 KA protection is guaranteed by the duplex of the RF module. An external lightning protection unit is needed for the higher protection other than 10 KA DC power port(external SPD) 20 kA ± 5 times, Residual Voltage is less than 250 V. Shielded cable is used for the R8882 remote power supply Signal port—dry contact 3KA Signal port—RS485 signal 3KA AISG power 5KA Signal port—AISG 485 port 3KA Radiation Transmission Frequency range (MHz) Quasi-peak limit (dBuV/m) (m) ) Distance( 30~230 30 10 230~1000 37 10 1G~3G 50 10 3G~6G 54 10 3-4 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 3 Product Technical Specifications Power Conducted Transmission Frequency range (MHz) Sum limit(dBuV) Quasi-peak Average value 0.15~0.50 56~66 46~56 0.50~5 56 46 5~30 60 50 Signal Conducted Transmission Frequency range 0.15 MHz~0.5 MHz 0.5 MHz~30 MHz Sum limit Quasi-peak Average value 84 dBuV~74 dBuV (Voltage) or40 74 dBuV~64dBuV (Voltage) or 30 dBuV~30 dBuA (Current) dBuV~20 dBuA (Current) 74 dBuV (Voltage) or 30dBuA 64dBuV (Voltage) or 20dBuA (Current) (Current) RF Electromagnetic Field Conducted Immunity Frequency range Voltage Feature Decision Rule 0.15 MHz~80 MHz 10 V 80%AM(1kHz) Rule A Surge Immunity Site Indoor Open circuit Voltage Type Wire—Wire Wire—Ground DC power 0.5 Long distance wire (wire length longer than 10 meters) Short distance wire (wire length less than 10 meters) 3.9 Reliability Item Characteristics MTBF ≥34,0000 hours MTTR 1 hour Availability ≥99.999842% 3-5 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual This page intentionally left blank. 3-6 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Table of Contents Safety Description ......................................................................................................4-1 Device Unpacking and Inspection...............................................................................4-5 Device Installation ......................................................................................................4-6 Cables Connection ...................................................................................................4-23 4.1 Safety Description 4.1.1 Safety Specifications Introduction In order to avoid accidents, before installing or maintaining the ZXSDR R8882 L200, please read this manual carefully for safety issues. If there are any local safety specifications, use the safety specifications described in this manual as a supplement. If there is any conflict between them, please follow the local safety specifications. The personnel who install or maintain the ZXSDR R8882 L200 must be equipped with knowledge of safety operation, technical training, correct knowledge of equipment operation and maintenance, and corresponding qualifications. When installing or maintaining the ZXSDR R8882 L200, the operator must follow the precautions of the equipment and special instructions provided by ZTE CORPORATION. Furthermore, the security issues listed in this manual are only friendly reminders by ZTE CORPORATION from safety point of view. ZTE is not responsible for any accident caused by violations of general safety operating requirements, or by violations of the design, production and use of equipment safety standards. 4.1.2 Safety Symbols Common safety symbols are shown in Table 4-1. These symbols are used to remind the user with safety matters when they maintain the equipment. Table 4-1 Symbol type and meanings Symbols Meanings No Touch Sign: DO NOT touch General Warning Sign: General security issues 4-1 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Symbols Meanings Electric Shock Warning Sign: Beware of high voltage Antistatic Sign: The device is sensitive to electrostatic charge or static electricity Microwave Warning Sign: Be careful of strong electromagnetic fields Laser Warning Sign: Be careful of intense laser beam Burn Warning Sign: Be careful of high temperature The general warning sign falls into three safety severities: Danger, Warning and Caution, from major to minor. The severity is marked on the right of the symbol and detailed descriptions are placed under the symbol. Their formats and descriptions are shown as below. Danger! Ignoring the safety warning may cause death or serious personal injuries, or equipment damage or breakdown. Warning! Ignoring the safety warning may cause major serious injuries, equipment damage or service interruption. Caution! Ignoring the safety warning may cause serious injuries, equipment damages or interruption of some services. 4-2 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation 4.1.3 Safety Operation Guidance Electrical Safety 1. Tool When operating in the case of high voltage, use special tools. Do not use general tools. 2. Power Cable l Cut off the power before installing or removing the power cable. l Before connecting the power cable, make sure the cable connection and labels on the cable comply with the actual installation situation. Danger! Do not install or remove the power cable when the power is ON. Sparks or electric arc may happen when the power cable touches the conductor, which may cause fire or eye injury. 3. Drilling l Unqualified drilling will damage the lines and cables in the cabinet. The metal splashes may enter the cabinet and cause the short circuit on the circuit board. l When drilling on the cabinets is needed, wear insulating gloves and remove the cables inside the cabinet before the operation. Take care of your eyes when drilling, because metal splashes may hurt your eyes. Clean up the metal filings once the drilling is done. Warning! Do not drill on the cabinet at will. 4. Thunderstorm During thunderstorm, strong electromagnetic field will be produced in the atmosphere. Thus, to avoid lightning strike, take lightning grounding measures on the equipment immediately. Danger! During thunderstorm, do not perform operations of high voltage, and do not perform operations on the iron tower or mast. 4-3 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Antistatic The friction caused by human activities is the reason to produce the accumulation of electrostatic charge. In dry climates, electrostatic voltage carried by the human body can be accumulated up to 30 kV, which will be kept in the body for couple of hours. Operators carrying electrostatic charge will be discharged through the device, causing equipment damage. To avoid damaging sensitive components by human static electricity, before touching the devices, such as boards, circuit boards, IC chips, operators should wear antistatic wristband, and make sure the other end of wristband touches the ground. To protect people from accidental electric shock, a resistance over 1 MΩ should be added between the antistatic wristband and the ground. The antistatic wristband should be inspected periodically. Do not replace the electric wires on the wristband by any other unqualified ones. Those electrostatic sensitive boards or modules should not have any contact with the objects of electrostatic charge or which carries static electricity easily. For example, friction between the packages of insulating materials and transmission belt could make the components carrying static electricity. Damages may happen when it is discharged by contacting human body. Those electrostatic sensitive boards can be only contacted with qualified discharged materials, such as antistatic bag. Equipment components need to be stored or transported in the antistatic bags. Before the testing equipment is wired with boards or modules, it should be connected to ground for discharging. Do not place the boards or modules near strong DC magnetic field. For example, those monitors with Cathode-ray tube, safety distance is over 10 cm. Caution! Electrostatic charge produced by human body will damage the electrostatic sensitive components on the circuit board, such as Integrated Circuit (IC), etc. Lifting Weights The adequate facilities with lifting capacity must be used for assembling, moving or replacing the heavy equipments. The staff for lifting operations are required to have qualified training. Lifting tools must have periodic inspection, and must be used when it is a complete tool kit. Ensure that the lifting tool can be firmly fixed on the fixture or load-bearing wall before any lifting operations. Use simplified commands to prevent misoperation. 4-4 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Warning! During lifting operations, do not walk at the bottom of any crane or lifting objects. Plugging/Unplugging Boards or Modules To avoid crooking the pin on backplane, plug the boards or modules gently. Plug the boards or modules along the slot to prevent any short circuit. When carrying the boards or modules, do not touch the circuits, as well as the components, connection heads, slots on the boards. Others Replacing the components or modifying the equipments may cause extra dangers. Do not replace the components or modify the equipments without authorization. From safety point of view, please contact ZTE CORPORATION for any queries. Caution! Do not perform maintenance or debugging inside the device, unless there is another qualified engineer working with you. 4.2 Device Unpacking and Inspection 4.2.1 Unpacking and Checking ZXSDR R8882 L200 Unpacking the Carton ZXSDR R8882 L200 is transported in a carton. 1. Check the packaging for damage. If it is damaged, make an immediate complaint to the transport company. 2. Unpack the equipment and check if it is complete according to the packing list. Inspecting the Device Check the Device and make sure: There are no dents, protrusions, bendings, peelings, or marks on the surface. Fastening bolts are properly tightened in place. The fittings and accessories required for installation are matched and complete. Connector links are not broken or missing. 4-5 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual The supplier should be responsible for inspecting the devices and instruments that are easy to be damaged. Separate the inspected parts by category. 4.2.2 Goods Handover After equipment inspection both the parties should sign the Unpacking and Inspection Report with each party keeping a copy, with the top copy returned within seven days to the vendor. Caution! If any goods are found to be wrong, missing, or damaged, record the details on the form and ask for replacements. 4.3 Device Installation 4.3.1 Mounting Device on Wall Context Note: The eRRU in this chapter are only for demonstrating installation scenario. Prerequisite Before installing R8882, you should at least leave the following space for product future maintenance. Front side: 600 mm Back side: 40 mm Left and right side: 100 mm UP and down side: 250 mm Steps 1. Mark on installation positions based on layout marking template on wall, as shown in Figure 4-1, and then drill holes. 4-6 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-1 Template Hole Position 2. Fix the wall-mounting components onto the wall firmly with the bolts, as shown in Figure 4-2. Figure 4-2 Installing Wall-mounting Components 1. Hex Bolt 2. Spring Washer 3. Flat Washer 4. Insulation Washer 5. Wall-Mounting components 6. Expansion Bolt The wall-mounting components is installed on the wall, as shown in Figure 4-3. 4-7 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-3 Wall-mounting Components Fixed on Wall 3. Hang the device on the wall-mounting components on the notch department, as shown in Figure 4-4. Figure 4-4 Hang the Device on the Wall-mounting Components 4. Mount the ZXSDR R8882 L200 onto the wall-mounting components, and then fasten it with the M6x20 bolts, as shown in Figure 4-5. 4-8 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-5 Fasten Device 1. Insulation washer 2. Spring washer 3. Bolt The ZXSDR R8882 L200 is installed on wall, as shown in Figure 4-6. Figure 4-6 ZXSDR R8882 L200 Is Installed on Wall – End of Steps – 4-9 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual 4.3.2 Mounting Device on Pole 4.3.2.1 Mounting One Device on Pole Context The installation accessory for the lightning protection box is needed to be attached in advance, as shown in Figure 4-7. Figure 4-7 Attach Installation Accessory for Lightning Protection Box Steps 1. Fix the wall-mounting components and pole clip together, as shown in Figure 4-8. Figure 4-8 Fix Wall-mounting Components and Pole Clips 2. Fix the wall-mounting components and pole clips on the pole, as shown in Figure 4-9. 4-10 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-9 Fix Wall-mounting Components and Pole Clips on Pole 1. Bolt 2. Spring washer 3. Flat washer 4. Wall-mounting components 5. Pole Clips 3. Hang the device on the notch part of the wall-mounting components, as shown in Figure 4-10. Figure 4-10 Hang the Device on the Wall-mounting Components 4. Fix the device on the wall-mounting components, as shown in Figure 4-11. 4-11 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-11 Fix the Device on the Wall-mounting Components ZXSDR R8882 L200 is installed firmly on the pole, as shown in Figure 4-12. Figure 4-12 ZXSDR R8882 L200 Is Installed on Pole 5. Align the lightning protection box to the hole of the installation accessory, and the fasten the screws, as shown in Figure 4-13. 4-12 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-13 Attach Lightning Protection Box – End of Steps – 4.3.2.2 Mounting Two Devices on Pole Context The installation accessory for the lightning protection box is needed to be attached in advance, as shown in Figure 4-14. Figure 4-14 Attach Installation Accessory for Lightning Protection Box Steps 1. Fix the wall-mounting components and pole clip together, as shown in Figure 4-15. 4-13 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-15 Fix Wall-mounting Components and Pole Clips 2. Fix the wall-mounting components and pole clips on the pole, as shown in Figure 4-16. Figure 4-16 Fix Wall-mounting Components and Pole Clips on Pole 1. Bolt 2. Spring washer 3. Flat washer 4. Wall-mounting components 5. Pole Clips 3. Hang the devices on the notch part of the wall-mounting components respectively, as shown in Figure 4-17. 4-14 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-17 Hang the Devices on the Wall-mounting Components 4. Fix the devices on the wall-mounting components, as shown in Figure 4-18. Figure 4-18 Fix the Devices on the Wall-mounting Components 5. Align the lightning protection box to the hole of the installation accessory, and the fasten the screws, as shown in Figure 4-19. 4-15 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-19 Attach Lightning Protection Box – End of Steps – 4.3.2.3 Mounting Three devices on Pole Context The installation accessory for the lightning protection box is needed to be attached in advance, as shown in Figure 4-20. Figure 4-20 Attach Installation Accessory for Lightning Protection Box Steps 1. Fix the wall-mounting components and pole clip together, as shown in Figure 4-21. 4-16 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-21 Fix Wall-mounting Components and Pole Clips 2. Fix the wall-mounting components and pole clips on the pole, as shown in Figure 4-22. Figure 4-22 Fix Wall-mounting Components and Pole Clips on Pole 1. Bolt 2. Spring washer 3. Flat washer 4. Wall-mounting components 5. Pole Clips 3. Fix the third wall-mounting components by using the expansion components to the other two ones, as shown in Figure 4-23. 4-17 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-23 Fix the Third Wall-mounting Components 4. Hang devices on the notch part of the wall-mounting components respectively, as shown in Figure 4-24. Figure 4-24 Hang the Devices on the Wall-mounting Components 5. Align the lightning protection box to the hole of the installation accessory, and the fasten the screws, as shown in Figure 4-25. 4-18 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-25 Attach Lightning Protection Box – End of Steps – 4.3.3 Mounting Device on Gantry Steps 1. Assemble the gantry. a. Install the vertical shaft and the bottom plate by using the M5x16 screw, as shown in Figure 4-26. Figure 4-26 Install the Vertical Shaft and the Bottom Plate b. Fasten the vertical shaft and the cover plate by using the M5x16 screw, as shown in Figure 4-27. 4-19 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-27 Fasten the Vertical Shaft and the Cover Plate c. Install the slanted rack by using the M5x16 screw, as shown in Figure 4-28. Figure 4-28 Install the Slanted Rack 2. Drill holes a. According to the engineering design drawing, determine the installation position of the gantry and mark installation holes by using the marking pen.Figure 4-29 shows the installation holes of the gantry. 4-20 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-29 Mark the Drilling Holes Position b. Drill holes by using the electric percussion drill (drill bit: φ12) at the places where installation holes are marked. At the same time, use the vacuum cleaner to remove the dust generated during the drilling of holes. c. Put the expansion sleeve onto the metal cone of the expansion bolt, fasten the nut slightly, strike the expansion bolt into the installation hole by using the rubber hammer, fasten the nut tightly to make the bolt fully expanded, and then remove the nut, as shown in Figure 4-30. Figure 4-30 Install the Expansion Bolt 3. Install the gantry. 4-21 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual If the gantry is installed on the concrete floor, use the M10x100 expansion bolt, as shown in Figure 4-31; if the gantry is installed on the wooden floor, use the M10x40 tapping screw, as shown in Figure 4-32. Figure 4-31 Install the Gantry on Concrete Floor Figure 4-32 Install the Gantry on Wooden Floor 4. Install the wall-mounting components on the gantry. 5. Install the ZXSDR R8882 L200 on the wall-mounting components. The device is installed firmly on the gantry, as shown in Figure 4-33. 4-22 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-33 ZXSDR R8882 L200 Is Installed on Gantry Note: A copper bar is needed to attach at the side of the gantry to connect to the grounding bar. – End of Steps – 4.4 Cables Connection 4.4.1 Connection of External Cables Table 4-2 describes the connection of ZXSDR R8882 L200 external cables. Table 4-2 Connection of ZXSDR R8882 L200 External Cables Cable type Connection relation Description 4-23 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Power cable Connects the ZXSDR R8882 One end is circular 6-core cable L200 power interface to the connector (hole) with plastic power supply equipment cover, the other end is reserved interface for power cable and dry contact cable. The length of cable is based on the engineering survey. Grounding cable Connects one ZXSDR R8882 The grounding cable is made L200 ground bolt to the copper up of strands of flame-retardant bar wire. The cross sectional area of ZXSDR R8882 L200 grounding cable is 16 mm2. Copper lugs are crimped at both ends of the grounding cable. Fiber Connects to eBBU Environment monitor cable Connects the ZXSDR R8882 For the environment monitor L200 environment monitor cable, end A is PIN header. interface to the external monitor End B, with 3m length in total, components or the dry contact. is made depending on the field engineering conditions. AISG control cable Connects the ZXSDR R8882 AISG is used to control the L200 debugging interface electrical-adjustment antenna. (AISG) to the control interface of electrical-adjustment antenna. Antenna jumper Connects ZXSDR R8882 L200 The RF jumper usually uses to main feeder the finished 1/2″ jumper with 2m length. The jumper can be customized depending on actual conditions. One end of the jumper is N connector (male) and the other end is DIN connector (female). 4.4.2 External Cable Installation Flow Figure 4-34 lists the installation flow of external cable. This flow can be adjusted based on actual conditions. 4-24 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-34 External Cable Installation Flow 4.4.3 Connecting Power Cable Context Figure 4-35 shows power cable connection of PIMDC. 4-25 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-35 PIMDC Power Cable Connection 1. Power input cable of the PIMDC 2. Power input cable of the R8882 3. Dry contact cable Figure 4-36 shows the power cable of ZXSDR R8882 L200. Figure 4-36 Power Cable Table 4-3 describes the color and definition of inner core of the power cable. Table 4-3 Color and Definition of Inner Core of the Power Cable Core color Definition Signal Description Blue -48V -48V Blue -48V -48V Black -48 V GND -48V ground Black -48 V GND -48V ground White NODE_IN+ Dry contact Brown NODE_IN- Dry contact 4-26 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Note: 1. If the two-core cable is adopted, the blue core cable stands for -48 V and the black core cable stands for -48 V GND. 2. If the four-core cable is adopted, the two blue core cables connected in parallel stand for -48 V and the black core cables connected in parallel stand for -48 V GND. Steps 1. Connect power cable from PIMDC to ZXSDR R8882 L200 a. Connect end A of power cable to the PWR interface of the ZXSDR R8882 L200. b. Strip the protective coat of end B, and then connect the blue wires to -48V terminal and the black wires to -48VRTN terminal. Connect the white and blue dry contact wires to the Alarm terminals, as shown in Figure 4-37. Figure 4-37 PIMDC Connection (to R8882) 2. Connect power cable from PIMDC to lightning protection box a. Peel off an appropriate length of insulating layer of the PIMDC power input cable. b. Lead the end A of the cable through the waterproof plastic ring of the PIMDC, and then connect the blue wires to the -48V terminal and the black wires to the -48VRTN terminal. Fasten the power cable with a latch, as shown in Figure 4-38. 4-27 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-38 PIMDC Connection (to Lightning Protection Box) Note: This latch should be fully contacted with the shielded layer of the PIMDC input power cable. c. Connect the end B of the PIMDC input power cable to the output port of the indoor DC lightning protection box. Connect the blue wires to the -48V terminal and the black wires to the -48VRTN terminal. Note: Power for sectors α, β, and γ are connected to SPD-1, SPD-2, and SPD-3 terminals respectively. – End of Steps – 4.4.4 Connecting Grounding Cable Context The grounding cable of ZXSDR R8882 L200 is made up of strands of flame-retardant wire. Copper lugs are needed to be crimped at both ends of the grounding cable in advance, as shown in Figure 4-39. 4-28 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-39 Grounding Cable Steps 1. Connect one end of grounding cable to the grounding terminal of the device, as shown in Figure 4-40. Figure 4-40 R8882 Grounding Bar Connection 2. Connect the other end of the ground cable to PIMDC, and then connection the PIMDC to outdoor grounding bar, as shown in Figure 4-41. 4-29 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-41 PIMDC Grounding Bar Connection 3. Attach the label on the grounding cable. 4. Measure the grounding resistance and make sure it is less than 5 ohms. – End of Steps – 4.4.5 Connecting Fiber Between eBBU and eRRU Steps 1. Remove the protection cap from the optical fiber, and then detach the outer protection cover, as shown in Figure 4-42. Figure 4-42 Remove Protection Cap 2. Remove two white covers, as shown in Figure 4-43. 4-30 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-43 Remove Covers 3. Insert the optical fiber into the OPT1 port until it locks into place with a snap, as shown in Figure 4-44. Figure 4-44 Insert Optical Fiber 4. Insert the transparent sleeve into the OPT port fully, as shown in Figure 4-45. Figure 4-45 Insert Transparent Sleeve 5. Tighten the outer protection cover fully. 4-31 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-46 Tighten Connection 6. Connect the optical fibers of sectors α, β, and γ to the TX0/RX0, TX1/RX1, and TX2/RX2 ports of the BPL board located in the eBBU. – End of Steps – 4.4.6 Connecting Environment Monitor Cable Context The environment monitor cable provides a 485 interface, used for ZXSDR R8882 L200 environment monitor. It also provides four extension accesses for external dry contact monitor. End A is circular 8-core plug and end B is made depending on actual conditions. The total length is 3m. Figure 4-47 shows the structure of environment monitor cable. Figure 4-47 Environment Monitor Cable The connector, connecting the environment monitoring cable to ZXSDR R8882 L200, is 8-core straight welded connector (pin) mounted on panel. The connector appearance is shown in Figure 4-48. 4-32 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Chapter 4 Product Installation Figure 4-48 Appearance of Environment Monitor Cable The cable connector pins and connection are shown in Table 4-4. Table 4-4 Cable Pin Description Pin Core color Signal Description PIN1 Brown Dry contact input, positive polarity PIN2 Yellow Dry contact input, negative polarity PIN3 Blue Dry contact input, positive polarity PIN4 White Dry contact input, negative polarity PIN5 Green Positive RS485 bus signal PIN6 Grey Negative RS485 bus signal PIN7 Red Positive RS485 bus signal PIN8 Black Negative RS485 bus signal Note: Connect the first dry contact of eRRU to outdoor DC lightning protection box. Steps 1. Connect end A of environment monitor cable to environment monitor interface of ZXSDR R8882 L200 cabinet. 2. Connect end B of environment monitor cable to external monitor part or dry contact. 3. Attach the labels on end B. – End of Steps – 4.4.7 Connecting AISG Control Cable Context AISG is used to control the electrical-adjustment antenna. Figure 4-49 shows the structure of AISG control cable. 4-33 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-49 Structure of AISG Control Cable Table 4-5 describes the meaning of sequence number of AISG control cable. Table 4-5 Meaning of Sequence Number of AISG Control Cable Pins at end A Pins at End B Name Meaning PIN3 PIN1 RS485B RS485- PIN5 PIN2 RS485A RS485+ PIN6 PIN3, PIN4 DC DC output PIN7 PIN5, PIN6 DC RTN DC RTN NC Null PIN1, PIN2, PIN4, PIN8 Steps 1. Connect end A to ZXSDR R8882 L200 debugging interface (AISG) and screw down the bolt. 2. Connect end B to the control interface of electrical adjustment antenna and screw down the bolt. – End of Steps – 4.4.8 Connecting the RF Jumpers Steps 1. Connect the A-ends of two RF jumpers to the ANT1 and ANT4 ports of the ZXSDR R8882 L200. Connect the B-end to the corresponding port of the main antenna. 2. Spiral-wrap two-layer ultraviolet-proof adhesive tape around the ANT2 and ANT3 ports, and then tighten them fully by using black ultraviolet-proof cable ties. – End of Steps – 4-34 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Figures Figure 2-1 ZTE Distributed eNodeB Solution............................................................. 2-2 Figure 2-2 Product Location...................................................................................... 2-3 Figure 2-3 Product Overall Appearance .................................................................... 2-5 Figure 2-4 Star Networking Mode ............................................................................. 2-6 Figure 2-5 Operate and Maintain System Remotely .................................................. 2-6 Figure 2-6 Operate and Maintain System Locally ...................................................... 2-7 Figure 2-7 Product External Interfaces and Grounding Terminal................................ 2-7 Figure 2-8 LMT Interface .......................................................................................... 2-8 Figure 2-9 Product Indicators.................................................................................... 2-9 Figure 4-1 Template Hole Position ............................................................................ 4-7 Figure 4-2 Installing Wall-mounting Components ..................................................... 4-7 Figure 4-3 Wall-mounting Components Fixed on Wall ............................................... 4-8 Figure 4-4 Hang the Device on the Wall-mounting Components ............................... 4-8 Figure 4-5 Fasten Device.......................................................................................... 4-9 Figure 4-6 ZXSDR R8882 L200 Is Installed on Wall .................................................. 4-9 Figure 4-7 Attach Installation Accessory for Lightning Protection Box ..................... 4-10 Figure 4-8 Fix Wall-mounting Components and Pole Clips...................................... 4-10 Figure 4-9 Fix Wall-mounting Components and Pole Clips on Pole ......................... 4-11 Figure 4-10 Hang the Device on the Wall-mounting Components............................ 4-11 Figure 4-11 Fix the Device on the Wall-mounting Components ............................... 4-12 Figure 4-12 ZXSDR R8882 L200 Is Installed on Pole.............................................. 4-12 Figure 4-13 Attach Lightning Protection Box ........................................................... 4-13 Figure 4-14 Attach Installation Accessory for Lightning Protection Box ................... 4-13 Figure 4-15 Fix Wall-mounting Components and Pole Clips .................................... 4-14 Figure 4-16 Fix Wall-mounting Components and Pole Clips on Pole ....................... 4-14 Figure 4-17 Hang the Devices on the Wall-mounting Components.......................... 4-15 Figure 4-18 Fix the Devices on the Wall-mounting Components ............................. 4-15 Figure 4-19 Attach Lightning Protection Box ........................................................... 4-16 Figure 4-20 Attach Installation Accessory for Lightning Protection Box ................... 4-16 Figure 4-21 Fix Wall-mounting Components and Pole Clips .................................... 4-17 Figure 4-22 Fix Wall-mounting Components and Pole Clips on Pole ....................... 4-17 Figure 4-23 Fix the Third Wall-mounting Components............................................. 4-18 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential ZXSDR R8882 L200 User Manual Figure 4-24 Hang the Devices on the Wall-mounting Components.......................... 4-18 Figure 4-25 Attach Lightning Protection Box .......................................................... 4-19 Figure 4-26 Install the Vertical Shaft and the Bottom Plate ..................................... 4-19 Figure 4-27 Fasten the Vertical Shaft and the Cover Plate ..................................... 4-20 Figure 4-28 Install the Slanted Rack ....................................................................... 4-20 Figure 4-29 Mark the Drilling Holes Position ........................................................... 4-21 Figure 4-30 Install the Expansion Bolt..................................................................... 4-21 Figure 4-31 Install the Gantry on Concrete Floor.................................................... 4-22 Figure 4-32 Install the Gantry on Wooden Floor ...................................................... 4-22 Figure 4-33 ZXSDR R8882 L200 Is Installed on Gantry .......................................... 4-23 Figure 4-34 External Cable Installation Flow ........................................................... 4-25 Figure 4-35 PIMDC Power Cable Connection ......................................................... 4-26 Figure 4-36 Power Cable ........................................................................................ 4-26 Figure 4-37 PIMDC Connection (to R8882)............................................................. 4-27 Figure 4-38 PIMDC Connection (to Lightning Protection Box) ................................. 4-28 Figure 4-39 Grounding Cable.................................................................................. 4-29 Figure 4-40 R8882 Grounding Bar Connection ....................................................... 4-29 Figure 4-41 PIMDC Grounding Bar Connection ...................................................... 4-30 Figure 4-42 Remove Protection Cap ....................................................................... 4-30 Figure 4-43 Remove Covers ................................................................................... 4-31 Figure 4-44 Insert Optical Fiber............................................................................... 4-31 Figure 4-45 Insert Transparent Sleeve .................................................................... 4-31 Figure 4-46 Tighten Connection .............................................................................. 4-32 Figure 4-47 Environment Monitor Cable.................................................................. 4-32 Figure 4-48 Appearance of Environment Monitor Cable .......................................... 4-33 Figure 4-49 Structure of AISG Control Cable .......................................................... 4-34 II SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Tables Table 2-1 Product External Interfaces Description ..................................................... 2-8 Table 2-2 Product Indicator Description..................................................................... 2-9 Table 3-1 CPRI Interface Index ................................................................................. 3-2 Table 3-2 Receiver Sensitivity ................................................................................... 3-3 Table 4-1 Symbol type and meanings ...................................................................... 4-1 Table 4-2 Connection of ZXSDR R8882 L200 External Cables ............................... 4-23 Table 4-3 Color and Definition of Inner Core of the Power Cable............................. 4-26 Table 4-4 Cable Pin Description .............................................................................. 4-33 Table 4-5 Meaning of Sequence Number of AISG Control Cable............................. 4-34 III SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Tables This page intentionally left blank. IV SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential Glossary AISG - Antenna Interface Standards Group - 天线接口标准组 CPRI - Common Public Radio Interface - 通用公共无线接口 CRC - Cyclic Redundancy Check - 循环冗余校验 FCC - Federal Communication Commission - 联邦通信委员会(美国) LED - Light Emitting Diode - 发光二极管 QAM - Quadrature Amplitude Modulation - 正交幅度调制 QPSK - Quadrature Phase Shift Keying - 四相移相键控/正交移相键控 SDR - Software Defined Radio - 软件定义无线电设备 VSWR - Voltage Standing Wave Ratio - 电压驻波比 eBBU - evolved Base Band Unit - 演进的基带资源单元 eRRU - evolved Remote Radio Unit - 演进的远端射频单元 SJ-20110104194923-001|2011-01-19(R1.0) ZTE Proprietary and Confidential
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Creator : Arbortext 5.4 Modify Date : 2014:04:30 10:48:15+08:00 Config File : C:\Program Files\PTC\Arbortext PE M010\lib\standard.pdfcf Create Date : 2014:04:30 10:30:11+08:00 JPEG Quality : 80 EPS Processor : PStill version 1.74.14 Compression Type : auto Compression Level : 6 Graphics Resolution : 600 Graphics Resolution Threshold : 900 Page Count : 63 XMP Toolkit : XMP Core 4.1.1 Creator Tool : Arbortext 5.4 Format : application/pdf Producer : PDF-XChange Viewer [Version: 2.0 (Build 42.3) (Aug 14 2009; 21:00:02)] Page Layout : SinglePageEXIF Metadata provided by EXIF.tools