ZTE R8882S8500 ZXSDR R8882 S8500 is Macro Radio Remote Unit User Manual III
ZTE Corporation ZXSDR R8882 S8500 is Macro Radio Remote Unit III
ZTE >
Contents
User Manual III
ZXSDR R8882 Macro Radio Remote Unit Hardware Installation Guide Hardware Version: HV2.0 ZTE CORPORATION NO. 55, Hi-tech Road South, ShenZhen, P.R.China Postcode: 518057 Tel: +86-755-26771900 Fax: +86-755-26770801 URL: http://ensupport.zte.com.cn E-mail: support@zte.com.cn LEGAL INFORMATION Copyright © 2011 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice. Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information. The ultimate right to interpret this product resides in ZTE CORPORATION. Revision History Serial No. Publishing Date Publishing Reason R1.1 2012–01–30 Modified the following sections: R1.0 2011–11–30 Serial Number: SJ-20111021104623-004 Publishing Date: 2012–01-30 (R1.1) 1.1, Device Appearance 1.5, Installation Flow 3.2, Installation Assemblies 4.3, Connecting the DC Power Cable Appendix C, Assembling the Portal Frame First Edition Contents About This Manual ......................................................................................... I Chapter 1 Installation Overview ................................................................ 1-1 1.1 Device Appearance ............................................................................................ 1-1 1.2 Preparation for Installation .................................................................................. 1-2 1.2.1 Environment Inspection ............................................................................ 1-2 1.2.2 Equipment Table ...................................................................................... 1-2 1.2.3 Tools and Meters List................................................................................ 1-2 1.3 Installation Space Requirement........................................................................... 1-3 1.4 Unpacking Inspection ......................................................................................... 1-5 1.4.1 Counting Goods ....................................................................................... 1-5 1.4.2 Unpacking Crate ...................................................................................... 1-6 1.4.3 Unpacking Carton .................................................................................... 1-6 1.4.4 Acceptance and Handover ........................................................................ 1-7 1.5 Installation Flow ................................................................................................. 1-7 Chapter 2 PIMDC Installation .................................................................... 2-1 2.1 Overview ........................................................................................................... 2-1 2.2 Installing the PIMDC on the Front of the Device ................................................... 2-2 2.3 Installing the PIMDC on the Side of the Device..................................................... 2-2 Chapter 3 Device Installation .................................................................... 3-1 3.1 Overview ........................................................................................................... 3-1 3.2 Installation Assemblies ....................................................................................... 3-2 3.3 Wall-Mounted Installation.................................................................................... 3-7 3.3.1 Using Mounting Kit 1 to Mount the Device on a Wall ................................... 3-7 3.3.2 Using Mounting Kit 2 to Mount the Device on a Wall ................................. 3-10 3.4 Pole-Mounted Installation.................................................................................. 3-14 3.4.1 Using Mounting Kit 1 to Mount the Device on a Pole................................. 3-14 3.4.2 Using Mounting Kit 2 to Mount the Device on a Pole................................. 3-17 3.5 Portal Frame-Mounted Installation ..................................................................... 3-23 3.5.1 Using Mounting Kit 1 to Mount the Device on a Portal Frame .................... 3-23 3.5.2 Using Mounting Kit 2 to Mount the Device on a Portal Frame .................... 3-25 3.6 Installing the Protection Shade .......................................................................... 3-26 Chapter 4 Cabling....................................................................................... 4-1 4.1 Flow of Connecting External Cables .................................................................... 4-1 4.2 Connecting the Protective Grounding Cable ......................................................... 4-2 4.3 Connecting the DC Power Cable ......................................................................... 4-3 4.4 Connecting the Optical Fiber ............................................................................... 4-7 4.5 Connecting the Monitoring Cable......................................................................... 4-9 4.6 Connecting the AISG Cable ...............................................................................4-11 4.7 Connecting the Feeder Jumper ......................................................................... 4-12 Chapter 5 Post-Installation Check ............................................................ 5-1 Chapter 6 Concluding Routines................................................................ 6-1 Appendix A Waterproofing Outdoor Connectors ................................... A-1 Appendix B Labeling Specifications ....................................................... B-1 Appendix C Assembling the Portal Frame.............................................. C-1 Figures............................................................................................................. I Tables ............................................................................................................ III Index ...............................................................................................................V Glossary .......................................................................................................VII II About This Manual Purpose This manual describes how to install the ZXSDR R8882(take ZXSDR R8882 S9000(C) as an example) including installation overview, PIMDC installation, device installation, cabling, and post-installation check. There are two types of protection shades which are optional parts, here we take the old type for example to describe installation steps. Intended Audience This manual is intended for the following personnel: Personnel who install ZXSDR R8882 Maintenance engineers Related Documents Before installation, installation personnel must read and understand the following documents: Personal Health and Safety Information System Safety Information Installation personnel should make sure that the following documents are kept handy: ZXSDR ZXSDR ZXSDR ZXSDR ZXSDR ZXSDR ZXSDR R8882 Product Description R8882 Hardware Description R8882 Project Survey Report R8882 Environment Acceptance Report R8882 Installation Design Drawing R8882 Parts List R8882 Tools and Meters List What is in This Manual Chapter Summary Chapter 1, Installation Overview Describes the ZXSDR R8882 appearance, installation preparations, unpacking inspection and installation flow. Chapter 2, PIMDC Installation Describes the PIMDC installation. Chapter 3, Device Installation Describes three installation modes for R8882. Chapter 4, Cabling Describes R8882 external cables installation. Chapter 5, Post-Installation Check Describes post-installation check items. Chapter Summary Chapter 6, Concluding Routines Describes the follow-up tasks after installation. Appendix A, Waterproofing Outdoor Connectors Describes how to connect and seal outdoor connectors. Appendix B, Labeling Specifications Describes labeling specifications. Appendix C, Assembling the Portal Frame Describes how to install the portal frame. Conventions ZTE documents employ the following typographical conventions. Typeface Meaning Italics References to other Manuals and documents. “Quotes” Links on screens. Bold Menus, menu options, function names, input fields, radio button names, check boxes, drop-down lists, dialog box names, window names. CAPS Keys on the keyboard and buttons on screens and company name. Note: Provides additional information about a certain topic. Checkpoint: Indicates that a particular step needs to be checked before proceeding further. Tip: Indicates a suggestion or hint to make things easier or more productive for the reader. II Chapter 1 Installation Overview Table of Contents Device Appearance ....................................................................................................1-1 Preparation for Installation..........................................................................................1-2 Installation Space Requirement ..................................................................................1-3 Unpacking Inspection .................................................................................................1-5 Installation Flow .........................................................................................................1-7 1.1 Device Appearance Figure 1-1 shows the ZXSDR R8882 device appearance. Figure 1-1 ZXSDR R8882 1-1 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Dimensions: 480 mm (height) × 320 mm (width) × 150 mm (depth) Weight: 27 kg 1.2 Preparation for Installation 1.2.1 Environment Inspection Before installing the device, installation personnel should make sure that the site environment is inspected and the Environment Acceptance Report is issued. 1.2.2 Equipment Table This table gives the Materiel Description and Quantity required installing a ZXSDR R8882. Table 1-1 ZTE Parts and Equipment List for a RRU Material Name Quantity R8882 (RRU) RRU engineering accessory RRU installation assembly (wall-mounted installation assembly, pole-mounted installation assembly, or L-shaped portal frame) Device hook (U-shaped hook) 0–2 (used for Mounting Kit 1) RRU mounting piece 0–1 (used for Mounting Kit 2) RRU protection shade 0–1 (used for the RRU base) RRU external cable PIMDC 0–1 (used when the R8882 has no built-in lightning arrester, currently does not supporting AC) PIMDC mounting piece 0–1 (optional, used to secure the PIMDC to the front or flank sides of the R8882) 1.2.3 Tools and Meters List This table lists tools and meters required installing ZXSDR R8882. 1-2 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 1 Installation Overview Table 1-2 Tools and Meters List Item List General-purpose Measuring and ruling 5 m steel tape, 1 m ruler, gradienter, marker, drilling tools tools template (delivered with the device) Drilling tools Electric percussion drill (auxiliary drill bits) and vacuum cleaner Tightening tools Cross screwdrivers (M3–M6), Allen key (M6), adjustable wrench (M10), and torque wrench Small tools Snipe-nose pliers, diagonal pliers, vices, file, hacksaw, and hydraulic pressure pliers Auxiliary tools Chain wheel, Ladder, Rope, scissors, slip-proof gloves, safety helmet, connector card, paintbrush, and hot air blower Special-purpose tools Multi-functional crimping pliers and feeder connector knife Meters Digital multimeter, VSWR tester, earth resistance tester, base station tester, compass, field strength tester (for special purpose), and spectrum analyzer (for special purpose) 1.3 Installation Space Requirement Figure 1-2 shows the recommended space for installing ZXSDR R8882. 1-3 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Figure 1-2 Recommended Space for Installing ZXSDR R8882 (Unit: mm) Figure 1-3 shows the minimum space for installing ZXSDR R8882. 1-4 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 1 Installation Overview Figure 1-3 Minimum Space for Installing ZXSDR R8882 (Unit: mm) 1.4 Unpacking Inspection 1.4.1 Counting Goods Prerequisite The goods have been delivered to the site for installation. Context The goods counting needs to be jointly completed by the engineer- ing technicians from both ZTE and the operator. Steps 1. Count the total number of cargos, the status of packing crate and the shipping address on the cargo need to be checked. When all inspections are passed, start the unpacking inspection. 1-5 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide 2. Equipment check list and unpacking inspection report are packed in crate #1. The unpacking inspection report need to be checked out and archived first. 3. If any goods missing, default, wrong equipments, inaccuracy in number or damages are found, the Feedback For Unpacking Inspection needs to be filled out by engineering supervisor with relevant reason. It should be send back to ZTE as soon as possible for processing. – End of Steps – 1.4.2 Unpacking Crate Context The required tools are claw hammer, pliers, straight screw driver and crow bar. Steps 1. Insert a straight screw driver or a claw hammer into the metal lock on the cover of the wooden crate. Rotate the screw driver or the claw hammer to loosen the iron sheet. Then open it with crow bar and pliers. 2. Open up all the other metal locks on the wooden crate top surface and remove the top cover. 3. Take out the carton from the wooden crate. – End of Steps – 1.4.3 Unpacking Carton Context Cartons are generally used for packing spare parts for electronic equipments, terminal devices and ancillary materials. Spare parts for electronic equipments are delivered in static-free bags. The static-free protective measures are needed when unpacking. Unpacking tools: Oblique clamp, paper cutter Follow the two points during the unpacking process: The static-free bag should not be broken for future storage or repair purpose. Desiccant in the carton should be properly disposed and be kept away from children. Steps 1. Cut off packing bands with the oblique clamp. 2. Slice along the tapes on the edges of the case cover and mind the depth when cutting. 3. Open up the carton and take out the bubbles. 4. Check out the goods according to the check list attached to the carton. 1-6 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 1 Installation Overview 5. Take out the static-free bag. 6. Open up the static-free bag and take out the electronic device. – End of Steps – 1.4.4 Acceptance and Handover Steps 1. Inspection Check the good's name, model, number etc against the packing list. Verify each goods according to the following items: Any concave, convex, scratches, peeling, blistering, blot outside the case. Any paint stripping, scratches on the case. Any loosing screw, drop bolts or dislocation. Any missing parts. Place the goods inspected by categories. 2. Delivery The customer representative and engineering supervisor need to sign on the Unpacking inspection report after the inspection. If the contract specifies the goods be kept by the customer after the inspection, both parties need to sign on the Unpacking Inspection Report and transfer the goods to the customer. – End of Steps – 1.5 Installation Flow Figure 1-4 shows the flowchart of installing ZXSDR R8882, including PIMDC installation, device installation, and cabling. 1-7 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Figure 1-4 Flowchart of Installing ZXSDR R8882 1-8 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 2 PIMDC Installation Table of Contents Overview ....................................................................................................................2-1 Installing the PIMDC on the Front of the Device .........................................................2-2 Installing the PIMDC on the Side of the Device...........................................................2-2 2.1 Overview Figure 2-1 shows the appearance of the power interface module DC (PIMDC). Figure 2-1 PIMDC Appearance The dimensions of a PIMDC are 233.2 mm (Height) × 119 mm (Width) × 55 mm (Depth). If the device is configured with a PIMDC , installation personnel can install the PIMDC onto the device before installing the device. The PIMDC can be installed on the front or side of the device. 2-1 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide 2.2 Installing the PIMDC on the Front of the Device Steps 1. Put the PIMDC mounting piece in place and align the holes on the PIMDC mounting piece with the mounting holes on the device. 2. Tighten the four M6 screws with a screwdriver, as shown in Figure 2-2. Figure 2-2 Securing the PIMDC Mounting Base on the Front of the Device 3. Place the PIMDC on the mounting piece and tighten the two captive screws with a screwdriver, as shown in Figure 2-3. Figure 2-3 Securing the PIMDC on the Front of the Device – End of Steps – 2.3 Installing the PIMDC on the Side of the Device Steps 1. Unscrew the four screws on the left side of the RRU with an Allen key. 2-2 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 2 PIMDC Installation 2. Put the PIMDC mounting piece in place and tighten the four M6 screws with an Allen key, as shown in Figure 2-4. Figure 2-4 Securing the PIMDC Mounting Base on the Side of the Device 3. Place the PIMDC on the mounting piece and tighten the two captive screws with a screwdriver, as shown in Figure 2-5. Figure 2-5 Securing the PIMDC on the Side of the Device – End of Steps – 2-3 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide This page intentionally left blank. 2-4 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 3 Device Installation Table of Contents Overview ....................................................................................................................3-1 Installation Assemblies ...............................................................................................3-2 Wall-Mounted Installation ...........................................................................................3-7 Pole-Mounted Installation .........................................................................................3-14 Portal Frame-Mounted Installation............................................................................3-23 Installing the Protection Shade .................................................................................3-26 3.1 Overview Depending on the configured installation assemblies, installation personnel can install ZXSDR R8882 in one of the following modes: Wall-mounted installation Pole-mounted installation Portal frame-mounted installation The following table describes the installation positions supported by the installation assemblies of ZXSDR R8882. Table 3-1 Installation Positions Supported by the Installation Assemblies of ZXSDR R8882 Installation Position Description Round pole φ60 mm–φ120 mm (GB/T8162-99, φ60, φ76, φ89, and φ114): supports single-unit, double-unit, triple-unit, and quadro-unit solutions. φ40 mm–φ60 mm: supports only single-unit and double-unit solutions. Channel steel 60 mm–100 mm (GB/T707—1988 6.3, 6.5, 8, and 10): supports the single-unit solution. Angle steel 63 mm–100 mm (angle steel No. 6.3, 7, 7.5, 8, 9, and 10): supports the single-unit solution. High-speed railway tunnel Supports the single-unit solution. Installation personnel can use some assembly parts of the wall-mounted mode and design some new assembly parts as required. The designed assembly parts should support the RRU installation interfaces. 3-1 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Installation Position Description Indoor/Outdoor wall Supports the single-unit solution. The assembly parts are the same as that in pole-mounted mode. Indoor portal frame Supports four RRUs. The assembly parts are the same as that in pole-mounted mode. 3.2 Installation Assemblies Based on the installation mode and installation assembly, installation personnel can install ZXSDR R8882 in one of the following six ways: Use mounting kit 1 to mount the device on a wall. Use mounting kit 2 to mount the device on a wall. Use mounting kit 1 to mount the device on a pole. Use mounting kit 2 to mount the device on a pole. Use mounting kit 1 to mount the device on a portal frame. Use mounting kit 2 to mount the device on a portal frame. Installation Assembly of Mounting Kit 1 (Wall-Mounted) Table 3-2 describes the installation assembly of mounting kit 1 for wall-mounted installation. Table 3-2 Installation Assembly of Mounting Kit 1 (Wall-Mounted) Name Appearance Function Wall mounting assembly It is used to mount ZXSDR R8882 on a wall. Device hook (U-shaped hook) Install two U-shaped hooks at the back of the device to connect and secureZXSDR R8882 Installation Assemblies of Mounting Kit 2 (Wall-Mounted) Table 3-3 describes the installation assemblies of mounting kit 2 for wall-mounted installation. 3-2 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 3 Device Installation Table 3-3 Installation Assemblies of Mounting Kit 2 (Wall-Mounted) Name Appearance Function Wall mounting assembly It is used to mount ZXSDR R8882 on a wall. RRU mounting base It is installed on the back or side of ZXSDR R8882 to secure ZXSDR R8882 on the wall mounting assembly, pole mounting assembly, parallel mounting base, or pole mounting clamp. Installation Assemblies of Mounting Kit 1 (Pole-Mounted) Table 3-4 describes the installation assemblies of mounting kit 1 for pole-mounted installation. Table 3-4 Installation Assemblies of Mounting Kit 1 (Pole-Mounted) Name Appearance Wall mounting assembly Function It is used to mount ZXSDR R8882. Pole mounting piece It is used to secure ZXSDR R8882 on a pole. 3-3 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Name Appearance Function Device hook (U-shaped hook) Install two U-shaped hooks at the back of the device to connect and secureZXSDR R8882 Extension piece It is used to extend the pole mounting piece to mount ZXSDR R8882 with the wall mounting assembly. Installation Assemblies of Mounting Kit 2 (Pole-Mounted) Table 3-5 describes the installation assemblies of mounting kit 2 for pole-mounted installation. Table 3-5 Installation Assemblies of Mounting Kit 2 (Pole-Mounted) Name Appearance Pole mounting assembly Function It is used to secure ZXSDR R8882 on a pole. Parallel mounting base It is used to mount three ZXSDR R8882s on a pole. One parallel mounting base can mount two ZXSDR R8882s. The parallel mounting base is located between the RRU mounting base and pole mounting piece. RRU mounting base It is installed on the back or side of ZXSDR R8882 to secure ZXSDR R8882 on the wall mounting assembly, pole mounting assembly, parallel mounting base, or pole mounting clamp. 3-4 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 3 Device Installation Installation Assemblies of Mounting Kit 1(Portal Frame-Mounted) Table 3-6 describes the installation assemblies of the mounting kit 1 for portal frame-mounted installation. Table 3-6 Installation Assemblies of the Mounting Kit 1 (Portal Frame-Mounted) Name Appearance Portal frame Function It is fixed on the indoor floor to mount the mounting panel. Mounting panel It is installed on the portal frame to secure ZXSDR R8882. Device hook (U-shaped hook) Install two U-shaped hooks at the back of the device to connect and secureZXSDR R8882 3-5 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Installation Assemblies of Mounting Kit 2 (Portal Frame-Mounted) Table 3-7 describes the installation assemblies of mounting kit 2 for portal frame-mounted installation. Table 3-7 Installation Assemblies of Mounting Kit 2 (Portal Frame-Mounted) Name Appearance Portal frame Function It is fixed on the indoor floor to mount the pole mounting clamp. Pole mounting clamp It is installed on the portal frame to secure ZXSDR R8882. Transition board It is used to secure the pole clips to the portal frame. 3-6 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 3 Device Installation Name Appearance RRU mounting base Function It is installed on the back or side of ZXSDR R8882 to secure ZXSDR R8882 on the wall mounting assembly, pole mounting assembly, parallel mounting base, or pole mounting clamp. 3.3 Wall-Mounted Installation 3.3.1 Using Mounting Kit 1 to Mount the Device on a Wall Steps 1. Identify the installation position on the wall and draw lines: Draw lines on the wall by using the drilling template and mark the four drilling positions, as shown in Figure 3-1. Figure 3-1 Drilling Positions 3-7 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide 2. Drill holes and install expansion bolts: Drill four Ф16 mm×80 mm holes at the marked drilling positions by using a percussion drill and install expansion bolts. Use a vacuum cleaner to clean the dust when drilling holes. 3. Secure the wall mounting assembly: Secure the wall mounting assembly on the wall with the nuts removed from the expansion bolts, as shown in Figure 3-2. Figure 3-2 Securing the Wall Mounting Assembly 1. Nut 2. Spring washer 3. Flat washer 4. Insulation washer 5. Wall mounting assembly 6. Insulation plate 7. Expansion bolts 4. Install device hooks (two U-shaped hooks): Use the 12 M16 bolts disassembled from the ZXSDR R8882 to secure the two U-shaped hooks to the back of the device. See Figure 3-3. 3-8 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 3 Device Installation Figure 3-3 Install Device Hooks (Two U-shaped Hooks) 5. Mount the device on the wall mounting assembly: Hang ZXSDR R8882 on the hook on the wall mounting assembly, as shown in Figure 3-4. Figure 3-4 Mounting the Device on the Wall Mounting Assembly 6. Secure the device: Secure ZXSDR R8882 on the wall mounting assembly with four M6 screws, as shown in Figure 3-5. 3-9 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Figure 3-5 Securing the Device – End of Steps – 3.3.2 Using Mounting Kit 2 to Mount the Device on a Wall Steps 1. Identify the installation position on the wall and draw lines: Draw lines on the wall by using the drilling template and mark the four drilling positions, as shown in Figure 3-6. 3-10 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential Chapter 3 Device Installation Figure 3-6 Drilling Positions 2. Drill holes and install expansion bolts: Drill four Ф16 mm×80 mm holes at the marked drilling positions by using a percussion drill and install expansion bolts. Use a vacuum cleaner to clean the dust when drilling holes. 3. Secure the wall mounting assembly: Secure the wall mounting assembly on the wall with the nuts removed from the expansion bolts, as shown in Figure 3-7. 3-11 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential ZXSDR R8882 Hardware Installation Guide Figure 3-7 Securing the Wall Mounting Assembly 4. Install the RRU mounting base on the back of the device: Align the holes on the back of the device with the holes on the RRU mounting base and secure the RRU mounting base on the back of the device with four M6 screws, as shown in Figure 3-8. Figure 3-8 Installing the RRU Mounting Base on the Back of the Device 5. Mount and secure the device: Mount the RRU mounting base on the wall mounting assembly, push the locking shim to lock the RRU mounting base, and then tighten the two screws on the locking shim, as shown in Figure 3-9 and Figure 3-10. 3-12 SJ-20111021104623-004|2012–01-30 (R1.1) ZTE Proprietary and Confidential
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 30 Producer : PDF Editor 2.0 - Foxit Software Author : Create Date : 2012:04:26 16:07:22 Modify Date : 2012:04:26 16:07:22EXIF Metadata provided by EXIF.tools