Zalman Tech TNN400APF-V2 Power Supply User Manual TNN400APF V2 Spec
Zalman Tech Co., Ltd. Power Supply TNN400APF V2 Spec
Users Manual
User Manual
TNN400APF-V2
Zalman Tech Co., Ltd.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
◎ Reorient or relocate the receiving antenna.
◎ Increase the separation between the equipment and receiver.
◎ Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
◎ Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void the user's authority to
operated the equipment under FCC rules.
0A
-5VDC ±10% 0.3A
ZALMAN SPECIFICATION
factor switching Power Supply. Especially, It is applied to the line input capability,
2.1 AC INPUT LINE REQUIREMENTS
+3.3VDC
-12VDC
+5VSB
±5%
Efficiency
400. Watt max Continuous
Form-factor
1. INTRODUCTION
The "TNN400APF-V2" is a Power Supply designed to be used "ATX/ATX12V" form factor
The scope of this document is limited to the requirements of "ATX/ATX12V" PC form
±5%
±5%
MODEL NO: TNN400APF-V2 REV.0
POWER
Vin FREQUENCY
MIN
Vin(230VAC)
Vin(115VAC)
NOM
5
2. ELECTRICAL SPECIFICATION
Vin(230VAC)
90
180
47
Vin(115VAC)
Parameter
VACrms
VACrms
A
A
Hz
UNIT
115
230
MAX
PAGE: 1/7
Output
voltage Requla
-tion
+12V2DC
+5VDC
±5%
±5%
+12V1DC ±5%
2.5A
Min load(Amps)
27.0A
0.8A
2A
Max load(Amps)
18
26.0A
0A
Peak current(Amps)
≥75% at Full load
1 16 18
0A
personal computers.
1.1 SCOPE
DATE: 2004. 04. 30
1
0.5A
0.5A
ATX/ATX12V
440. Watt max peak
remote ON/OFF, cooling, standby voltage("VSB") and electrical characteristics.
-
135
265
63
10
Amps+12V1DC 1.0
-5VDC
"
+12.6 Volts
-10
-
-
-
11.5
0.5
0.5
0.0
0.3-
-5VDC 0.0
+12V2DC
+5VSB
10
-5V ±10% -4.75 -5.00
+5VDC
+3.3VDC
0.0
-
"-1.0-
Load)
-0.5
"3.0
"-1.0
"
"-
-
1.0
0.0
0.0
-"0.3
"
"
16
-
+12.6 Volts
+12V2DC 1.0
-
MAX
4) It shall not exceed 17 seconds in duration at peak +12VDC output power, 234Watts.
PEAK
+5VSB
1) Maximum continuous total DC output power shall not exceed 400Watts.
±5% +5.00 Volts+4.75
2.2.2 DC output CURRENT
+12.00+12V1DC
+5VDC
+12V2DC ±5%+11.4 +12.00
±5% +11.4
-12VDC ±10%
+4.75 +5.00
+3.3VDC +3.30
-12.00-10.80
+3.14±5%
+5.25 Volts
-13.20
+5.25
-5.25 Volts
Volts
+3.47
"
"
(normal -
5.0
+5VSB
MODEL NO: TNN400APF-V2 REV.0
--12VDC
ZALMAN SPECIFICATION PAGE: 2/7
0.0
DATE: 2004. 04. 30
"-
-0.3
Load)
Range 2
1.0
0.5
+3.3VDC
-12VDC
0.5
2) Maximum +5V and +3.3V output power shall not exceed 180Watts.
Parameter
+12V1DC Amps
3) Maximum Peak Total DC output power shall not exceed 440Watts.
5) Output voltage of +5VSB shall be maintained within the power shut down.
-
NOMMIN
(high 7.0
18
-
18
+5VDC
Range
Range 1
±5%
UNIT
TEST POINT : OUTPUT CONNECTOR LOAD TERMINALS.
Parameter MIN NOMRange MAX UNIT
Volts
2.1.1 INRUSH CURRENT
Max. inrush current shall not exceed 90A(Peak to Peak).
2.2 DC OUTPUT REQUIREMENTS
2.2.1 OUTPUT REQUIREMENTS
AC INPUT PSU LOAD
±1.0% -120 mVp-p
50 "-5VDC -
20MHz.
a 0.1㎌ Ceramic capacitors at each output with measuring band width from DC to
MAXNOR
"
-±1.0%
+5VDC ±1.0%
+12V1DC
2.2.3 EFFICIENCY
+12V2DC ±1.0% -
50
+3.3VDC
AC GROUND
. Load Slew Rate : 0.2A/㎲
2.2.5 OUTPUT TRANSIENT RESPONESE & OVERSHOOT AT TURN ON/OFF
MAX step -12VDC -5V
0.1A
AC NEUTRAL
-12VDC
AC LIVE
+5VSB ±1.0%
±1.0% -
±1.0%
-
Parameter Range MIN
. The measurements should be made by crossing a 10㎌ electrolytic capacitor and
V return
Voltage range -
SCOPE
"
1) The power supply at full load provide AC/DC conversion efficiency 75% minimum.
Parameter +5VSB
0.1A
+5VDC +3.3VDC
120
50
2.2.4 OUTPUT RIPPLE/NOISE
UNIT
"
"-
200
10㎌
V OUT 0.1㎌
50 "
±3% ±3%
Shoot range
DATE: 2004. 04. 30
-
9A 7.8A 8.1A 0.1A
±10%
±3% ±3% ±3%
+12V
PAGE: 3/7ZALMAN SPECIFICATION
±10% ±10%
MODEL NO: TNN400APF-V2 REV.0
±10% ±10%
T2 T3
ZALMAN SPECIFICATION
* PW-OK sense level : 95% of nominal
2.3.1 REMOTE ON/OFF CONTROL
PAGE: 4/7
MODEL NO: TNN400APF-V2 REV.0 DATE: 2004. 04. 30
2.3.2 POWER UP DELAY
PS_ON
PS_OFF
an active-low, TTL-compatible signal("PS-ON"). The +5VSB is on whenever the
AC power is present.
DC Enable
95%
10%
T4
. When PS-ON is pulled to TTL low, the DC outputs are to be enabled.
. When PS-ON is pulled to TTL high or open circuited, the DC outputs are
to be disabled. Turn ON/OFF delay ≥ 1000mS
The power supply DC outputs (with the exception of +5VSB) shall be enabled with
PWR-OK
2.3 TIMING / HOUSE KEEPING
The output voltages shall rise from <10% of nominal to within the regulation ranges
specified in sec 2.2.1 within 2 to 30ms.
Max UnitMin
15
7.0
. Power Down Warning : T4>1ms
2.4 OUTPUT PROTECTION
2.4.1. OVER VOLTAGE PROTECTION
15.6V
V+5VDC 5.74 6.3
+12VDC
4.3
. +12V2 : 19A~ at 12V2 at no load
ZALMAN SPECIFICATION
4.2+3.3VDC
13.4
3.76
MODEL NO: TNN400APF-V2 REV.0
. Logic level Low : <0.4V 4mA
DATE: 2004. 04. 30
. +5V : 29A~ Test Condition : Output Full Load
. +3.3V : 30A~
. +12V1 : 19A~ at 12V1 at no load
PAGE: 5/7
V
V
*Change latch mode at above voltage in power supply unit.
2.4.2. SHORT CIRCUIT PROTECTION
. Shutdown or latch at short +3.3, +5V and +12V.
. No damage in compenents, PCB trace connector at continous shout.
. The maximum short circuit current shall not exceed 240VA.
2.4.3. OVER POWER PROTECTION
. Logic level High :Between 2.4VDC and 5VDC output while sourcing current, 200㎂
. Signal Type : Open Collector +5VDC, TTL compatible.
. POK Delay : 100mS<T3<500ms
2.3.4 VOLTAGE HOLD-UP TIME
The power supply shall maintain output regulation per section 2.2.1 despite
Parameter
a loss of input power at the low-end nominal range at maximum continuous
Nom
output load as specified in section 1.1 for a minimum 16ms.
2.3.3 POWER GOOD SIGNAL, POK
Primary lot is output full load at 55℃ 24HR
. Primary to Secondary : 500VDC 100㏁
. Primary to FG : 500VDC 100㏁
. UL1950
2.4.4 DC INPUT PROTECTION
2.4.7. This power supply shall comply with the followings.
On
2.4.10. INSULATION VOLTAGE WITHSTAND
. IEC950
Output Status
2.4.9. POWER SWITCH On/Off TEST
. VDE 0871/6.78 Class B
2.4.5. BURN-IN
2.4.11. LEAKAGE CURRENT(IEC950)
. The Maximum Leakage Current Following The Frame / AC Sine Conductor
PAGE: 6/7
MODEL NO: TNN400APF-V2 REV.0
ZALMAN SPECIFICATION
Shall be 1.0mA Maximum at 220VAC Input
2.4.6. MEAN TIME BETWEEN FAILURES
. Operating Time 50,000HR at 25℃.
OffLogic " High"
DATE: 2004. 04. 30
Logic " Low"
. CSA C22.2 NO220 & CSA Bulletin 1402C, Level3
Control Signal
. VDE 0806, EN60950 A3
. Use proper fuse for DC input over current protection.
. FCC Part 15 Sub Part B, Class B
2.4.8. EMI
. Between Input and Output : 1500VAC 10mA 1min or 1800VAC 10mA 3sec
. Storage : -20℃ ~ 85℃
2.4.12. DIELECTRIC STRENGTH
. Phase : 0 - 360˚
. Between Input and FG : 1500VAC 10mA 1min or 1800VAC 10mA 3sec
. Operating : 5℃ ~ 25℃
2.4.13. TEMPRATURE RANGE
. Polarity : +, -
. Mode : Common, Normal
2.4.14. HUMIDITY RANGE
. Operating : 20% ~ 80%
. Storage : 10% ~ 95%
. The power Supply Must not generate Acoustic Noise in excess of 30dB at a
2.4.15. VIBRATION TEST
. Non Operation : Sweep Test
. Frequency : 5 ⇒ 20 ⇒ 500 ⇒ 5Hz
. Acceleration :0.02G
2.4.16. ACOUSTIC NOISE
. Airection : X, Y, Z
. Period : 6 Minutes
. Cycie : 10
Distance of 1 Meter from any Point on The requirments Surface.
MODEL NO: TNN400APF-V2 REV.0 DATE: 2004. 04. 30
ZALMAN SPECIFICATION PAGE: 7/7
2.4.18. AC LINE NOISE
. The Power Supply Shall Operate Normally When AC Line Noise is Applied
. Noise Crest Value : 1000VAC
. Pulse Width : 1㎲
. Time : 3Minutes