Zebra Technologies MC3090Z Mobile Computing Terminal User Manual Manual 1

Zebra Technologies Corporation Mobile Computing Terminal Manual 1

Contents

Manual 1

MC3090-Z RFID Mobile ComputerIntegrator Guide
MC3090-Z RFID Mobile ComputerIntegrator Guide72E-125046-01Revision .2November 2009
ii MC3090-Z RFID Mobile Computer Integrator Guide© 2009 by Motorola, Inc. All rights reserved.No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Motorola. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. Motorola grants to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of Motorola. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Motorola. The user agrees to maintain Motorola’s copyright notice on the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof.Motorola reserves the right to make changes to any software or product to improve reliability, function, or design.Motorola does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.No license is granted, either expressly or by implication, estoppel, or otherwise under any Motorola, Inc., intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in Motorola products.MOTOROLA and the Stylized M Logo and Symbol and the Symbol logo are registered in the US Patent & Trademark Office. Bluetooth is a registered trademark of Bluetooth SIG. Microsoft, Windows and ActiveSync are either registered trademarks or trademarks of Microsoft Corporation. All other product or service names are the property of their respective owners. Motorola, Inc.One Motorola PlazaHoltsville, New York 11742-1300http://www.motorola.com/enterprisemobilityPatentsThis product is covered by one or more of the patents listed on the website:  http://www.motorola.com/enterprisemobility/patents.WarrantyFor the complete Motorola hardware product warranty statement, go to: http://www.motorola.com/enterprisemobility/warranty.
 iiiRevision HistoryChanges to the original manual are listed below:Change Date Description-01 Rev .1 10/2009 Beta draft-01 Rev .2 11/2009 Post-beta draft
iv MC3090-Z RFID Mobile Computer Integrator Guide
Table of ContentsAbout This GuideIntroduction .................................................................................................................... viiConfigurations................................................................................................................ viiChapter Descriptions ..................................................................................................... viiiNotational Conventions.................................................................................................. viiiRelated Documents and Software................................................................................. ixService Information........................................................................................................ ixChapter 1: Getting StartedIntroduction ................................................................................................................... 1-1RFID Technology Overview .......................................................................................... 1-1RFID Components  .................................................................................................. 1-2MC3090-Z RFID Mobile Computer  ............................................................................... 1-3MC3090-Z RFID Mobile Computer Parts ................................................................ 1-4MC3090-Z RFID Mobile Computer LEDs  ............................................................... 1-5Reading Tags  ............................................................................................................... 1-5Chapter 2: Updating the Mobile ComputerIntroduction ................................................................................................................... 2-1Updating the Device Image  .......................................................................................... 2-1Downloading an Update Loader Package  .............................................................. 2-1Updating Images via ActiveSync  ............................................................................ 2-1Updating Images via AirBEAM ................................................................................ 2-2Updating the RFID Firmware  ........................................................................................ 2-2Downloading Firmware Files ................................................................................... 2-2Updating the Firmware using the RFID_FLASH Utility  ........................................... 2-3Chapter 3: LLRP FunctionalityIntroduction ................................................................................................................... 3-1LLRP Icons  ................................................................................................................... 3-2LLRP Menu ................................................................................................................... 3-2
vi MC3090-Z RFID Mobile Computer Integrator GuideConfigure LLRP  ...................................................................................................... 3-3Version Information ................................................................................................. 3-3Exit LLRP ................................................................................................................ 3-4LLRP Registry Entries  .................................................................................................. 3-4Chapter 4: RFID Sample ApplicationIntroduction ................................................................................................................... 4-1Launching the RFID Sample Application  ...................................................................... 4-2Sample Application Menu Options ................................................................................ 4-3Configuration Menu Options  ................................................................................... 4-3Operations Menu Options ....................................................................................... 4-6Management Menu Options .................................................................................... 4-11About ....................................................................................................................... 4-13Reading Tags  ............................................................................................................... 4-14Chapter 5: TroubleshootingIntroduction ................................................................................................................... 5-1Troubleshooting ............................................................................................................ 5-1Appendix A: Technical SpecificationsTechnical Specifications  ............................................................................................... A-1Cable Pinouts  ............................................................................................................... A-4USB Client Connector ............................................................................................. A-4GPIO Port Connections  .......................................................................................... A-5Appendix B: RFID APIsIndex
About This GuideIntroductionThis MC3090-Z RFID Integrator Guide provides the unique set up and operating procedures for the MC3090-Z RFID mobile computers. This guide is intended as a supplement to the MC3000 Integrator Guide, p/n 72E-68900-xx. Procedures common to MC3000 products are addressed in the MC3000 Integrator Guide.ConfigurationsThis guide covers the following configuration:NOTE     Screens and windows pictured in this guide are samples and may differ from actual screens.Configuration Radios Display Memory Data Capture OperatingSystem KeypadMC3090Z-LC48HBAQE1 (US only) WLAN: 802.11a/b/gWPAN: Bluetooth Color 128 MB RAM/1 GB Flash ImagerRFID Windows Mobile 6.1 Classic48 alpha- numeric keysMC3090Z-LC48HBAQE2(Canada and other countries in US band 902-928MHz)WLAN: 802.11a/b/gWPAN: Bluetooth Color 128 MB RAM/1 GB Flash ImagerRFID Windows Mobile 6.1 Classic48 alpha- numeric keys
viii MC3090-Z RFID Mobile Computer Integrator GuideChapter DescriptionsTopics covered in this guide are as follows:•Chapter 1, Getting Started provides an overview of RFID technology and components and a description of the MC3090-Z RFID mobile computer and features.•Chapter 2, Updating the Mobile Computer describes how to update the device image and radio firmware.•Chapter 3, LLRP Functionality includes information on configuring the LLRP RFID application and reading tags.•Chapter 4, RFID Sample Application provides information on the RFID sample application and how to use it to assist in custom application development.•Chapter 5, Troubleshooting describes MC3090-Z RFID mobile computer troubleshooting procedures. •Appendix A, Technical Specifications includes the technical specifications for the reader.•Appendix B, RFID APIs provides a reference for information on supported RFID APIs.Notational ConventionsThe following conventions are used in this document:•“Mobile computer” or “reader” refers to the MC3090-Z RFID mobile computer. •Italics are used to highlight the following:•Chapters and sections in this and related documents•Dialog box, window, links, software names, and screen names•Drop-down list, columns and list box names•Check box and radio button names•Icons on a screen •Bold text is used to highlight the following:•Dialog box, window and screen names•Drop-down list and list box names•Check box and radio button names•Icons on a screen•Key names on a keypad•Button names on a screen•Bullets (•) indicate:•Action items•Lists of alternatives•Lists of required steps that are not necessarily sequential.•Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.
About This Guide ixRelated Documents and SoftwareThe following documents provide more information about the reader.•MC3090-Z RFID Mobile Computer Quick Start Guide, p/n 72-71347-xx•MC3090-Z RFID Mobile Computer Regulatory Guide, p/n 72-68903-xx•MC3000 Mobile Computer User Guide, p/n 72E-68899-xx•MC3000 Mobile Computer Integrator Guide, p/n 72E-68900-xx•Microsoft Applications for Windows Mobile 6 User Guide, p/n 72E-108299-xx•Application Guide for Motorola Enterprise Mobility Devices, p/n 72E-68902-xx•Wireless Fusion Enterprise Mobility Suite User Guide for Version 2.55, p/n 72E-107170-01•Mobility Services Platform 3.2 User’s Guide, p/n 72E-100158-xx•MC3090-Z RFID Enterprise Mobility Developer KitFor the latest version of this guide and all guides, go to: http://www.motorola.com/enterprisemobility/manuals.Service InformationIf you have a problem with your equipment, contact Motorola Enterprise Mobility support for your region. Contact information is available at: http://www.motorola.com/enterprisemobility/contactsupport. When contacting Enterprise Mobility support, please have the following information available:•Serial number of the unit •Model number or product name •Software type and version number Motorola responds to calls by e-mail, telephone or fax within the time limits set forth in service agreements.If your problem cannot be solved by Motorola Enterprise Mobility Support, you may need to return your equipment for servicing and will be given specific directions. Motorola is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty.If you purchased your Enterprise Mobility business product from a Motorola business partner, please contact that business partner for support.
x MC3090-Z RFID Mobile Computer Integrator Guide
Chapter 1 Getting StartedIntroductionThis chapter provides an overview of RFID technology and components, and describes the MC3090-Z RFID mobile computer and its features.RFID Technology OverviewRFID (Radio Frequency Identification) is an advanced automatic identification (Auto ID) technology that uses radio frequency signals to identify tagged items. An RFID tag contains a circuit that can store data. This data may be pre-encoded or can be encoded in the field. The tags come in a variety of shapes and sizes. To read a tag the mobile computer sends out radio frequency waves using its integrated antenna. This RF field powers and charges the tags, which are tuned to receive radio waves. The tags use this power to modulate the carrier signal. The reader interprets the modulated signal and converts the data to a format for computer storage. The computer application translates the data into an understandable format.Figure 1-1    RFID System ElementsHost ComputerTagsMobile ComputerPhysical/Network ConnectionRF Wave and Response
1 - 2 MC3090-Z RFID Mobile Computer Integrator GuideRFID ComponentsMotorola RFID solutions offer low cost, long read range, and a high read rate. These features provide real time end-to-end visibility of products and assets in the factory, distribution center, retail outlet, or other facility. The MC3090-Z RFID system consists of the following components: •Silicon-based RFID tags that attach to retail products, vehicles, trailers, containers, pallets, boxes, etc.•An integrated antenna that supports applications such as item level tracking and asset tracking.•An embedded radio module that powers and communicates with tags for data capture and provides host connectivity for data migration.TagsTags contain embedded chips that store unique information. Available in various shapes and sizes, tags, often called transponders, receive and respond to data requests. Tags require power to send data, and are available with two power options:•Active Tags: typically powered by light-weight batteries and have limited life.•Passive Tags: the RFID reader generates an RF field that powers the tag. Passive tags are much lighter, less expensive, and have a much longer life than active tags.AntennaAntennas transmit and receive radio frequency signals. A read point is the RF range of an antenna.Radio ModuleThe radio module communicates with the tags and transfers the data to a host computer. It also provides features such as filtering, CRC check, and tag writing. The MC3090-Z RFID mobile computer reads Gen2 (dense reader mode) RFID tags.
Getting Started 1 - 3MC3090-Z RFID Mobile ComputerThe Motorola MC3090-Z RFID mobile computer includes an intelligent C1G2 UHF RFID reader with RFID read performance that provides real-time, seamless EPC-compliant tags processing. MC3090-Z RFID mobile computers are designed for indoor inventory management and asset tracking applications, and can host third-party, customer-driven embedded applications. Features include: •ISO 18000-6C standard (EPC Class 1 Gen 2)•Read, write, kill, and lock tag functionality•48-key alphanumeric keypad•3” color display•Orientation-insensitive integrated external antenna•Laser-based bar code reader•Windows® Mobile 6.1•WLAN 802.11 a/b/g wireless connectivity•Application-specific setup for ease of installation•Low Level Reader Protocol (LLRP)•Sample application and support for custom or third-party applications•RFID API support•Event and tag management supportFigure 1-2    MC3090-Z RFID Mobile ComputerIllustration to come
1 - 4 MC3090-Z RFID Mobile Computer Integrator GuideThe MC3090-Z RFID mobile computer provides a wide range of features that enable implementation of complete, high-performance, intelligent RFID solutions. MC3090-Z RFID Mobile Computer PartsFigure 1-3    MC3090-Z RFID Mobile Computer PartsNOTE     The MC3090-Z RFID mobile computer supports a 2x battery only, and does not work with a 1x battery.The MC3090-Z RFID mobile computer does not support the Four-Slot Cradle.Due to component tolerances, some users may experience undesired behavior when using battery part number 55-060112-xx. If the unit turns off without proper warning messages during heavy use, use battery part number 55-002152-xx. KeypadIndicator LED BarDisplayPowerScan ButtonBeeperTriggerScan LED Indicators (red/green)Charge LED Indicator (amber)Scan LEDIndicator(red/green)Updated illustration to come
Getting Started 1 - 5MC3090-Z RFID Mobile Computer LEDsThe mobile computer LEDs indicate charging and reader status as described in Table 1-1.Reading TagsTo read RFID tags: 1. Remove the MC3090 from AC power and ensure the LLRP icon is green.2. Use an RFID reader application to enable tag reading. For a sample application, browse to the MC3090 Application directory and select RFIDSample3Plus.exe. See Chapter 4, RFID Sample Application.3. Aim the mobile computer at the tag, oriented horizontally or vertically depending on the tag orientation. The distance between the tag and the antenna is the approximate read range.4. Press the trigger or tap the on-screen Read command within the application to interrogate all RFID tags within the radio frequency (RF) field of view and capture data from each new tag found. Release the trigger or tap the Stop Read command to stop interrogating tags.Table 1-1     LED Status IndicatorsLED IndicationCharging IndicatorsOff Mobile computer not placed correctly in the cradle; cable not connected correctly; charger is not powered.Fast Blinking Amber Error in charging; check placement of mobile computer. Slow Blinking Amber Mobile computer is charging.Solid Amber Charging complete.Note: When the battery is initially inserted in the mobile computer, the amber LED flashes once if the battery power is low or the battery is not fully inserted.NOTE When connected to power, the mobile computer cannot read RFID tags.
1 - 6 MC3090-Z RFID Mobile Computer Integrator Guide
Chapter 2 Updating the Mobile ComputerIntroductionThis chapter describes how to update the device image and radio firmware.Updating the Device ImageWindows Mobile contains an Image Update feature that updates all operating system components. Motorola distributes all updates as update packages on the Support Central Web Site http://www.motorola.com/enterprisemobility/support. These packages contain either partial or complete updates for the operating system.To update an operating system component, copy the update package to the mobile computer using ActiveSync, AirBEAM, or MSP. Downloading an Update Loader Package1. Download the appropriate update loader package from the Motorola Support Central web site http://www.motorola.com/enterprisemobility/support to a host computer.2. Locate the update loader package file on the host computer and un-compress the file into a separate directory:•30XXw61RFIDSCxxxxx.zip for updating via ActiveSync•30XXw61RFIDABxxxxx.zip for updating via AirBEAMUpdating Images via ActiveSyncTo install an update loader package using ActiveSync:1. Insert the mobile computer into the cradle and connect the cradle to AC power. 2. Connect the mobile computer to the host computer using ActiveSync. 3. In ActiveSync on the host computer, open Explorer for the mobile computer.4. Copy the contents of 30XXw61MenUPR10903\UpdateLoader (the files only, not the folder) into the \Storage Card folder on the mobile computer.
2 - 2 MC3090-Z RFID Mobile Computer Integrator Guide5. On the mobile computer, navigate to the \Storage Card folder and tap the program STARTUPDLDR.EXE. The update takes approximately 10 minutes. Do not remove AC power during this time.6. Copy the contents of 30XXw61RFIDPkgXXXX (the files only, not the folder) into the \Storage Card folder on the mobile computer.7. Remove the mobile computer from the cradle or AC power if charged. 8. On the mobile computer, navigate to the \Storage Card folder and tap the program RFIDSetup.exeThe device boots after the installation. Note that the RFID LLRP application disconnects when the mobile computer is charging, and re-connects when the mobile computer is removed from AC power.Updating Images via AirBEAMInstall the AirBEAM package files within 30XXw61RFIDABxxxxx.zip in sequence:1. 30XXw61MenUPRXXXXX.apf2. 30XXw61RFIDPkgXXXX.apf30XXw61RFIDPkgXXXX.apf executes silently and the mobile computer boots after installation, which takes approximately 7-10 seconds. Refer to the MC3000 Integrator Guide for more information on AirBEAM.Updating the RFID FirmwareUse the RFID_FLASH utility to update the firmware for the RFID radio. Motorola distributes the firmware update files on the Support Central Web Site http://www.motorola.com/enterprisemobility/support.Downloading Firmware Files1. Download the firmware update files from the Motorola Support Central web site http://www.motorola.com/enterprisemobility/support to a host computer.2. Connect the mobile computer to the host computer using ActiveSync. 3. In ActiveSync on the host computer, open Explorer for the mobile computer.4. Copy the firmware file and the OEM data file into the \Application folder on the mobile computer.NOTE If you exit LLRP via the icon menu, to restart it use File Explorer on the mobile computer to navigate to \Application\LLRP\ and tap the OzoneLLRP.exe application.
Updating the Mobile Computer 2 - 3Updating the Firmware using the RFID_FLASH Utility1. On the mobile computer, navigate to the \Application folder and tap the program RFID_FLASH. Figure 2-1    RFID_FLASH Window2. Tap Browse for Firmware File.3. In the Open window, select the firmware file.Figure 2-2    Selecting the Firmware File4. Tap Start Firmware and wait until the progress bar completes.Figure 2-3    Starting Firmware Update
2 - 4 MC3090-Z RFID Mobile Computer Integrator Guide5. Tap Browse for OEM Data File.6. In the Open window, select the OEM data file.Figure 2-4    Selecting the OEM File7. Tap Start OEM to start the update. Wait until the progress bar completes and OEM LOADED appears.Figure 2-5    Updating OEMNOTE When updating the OEM data file, the mobile computer displays a progress bar. This bar may indicate some progress, then move quickly to complete.
Chapter 3 LLRP FunctionalityIntroductionLow Level Reader Protocol (LLRP) is an RFID server application that runs in the background on the mobile computer. The LS icon in the system tray represents LLRP. This chapter includes information on using and configuring the LLRP RFID application.Figure 3-1    LLRP IconLLRP Server Icon
3 - 2 MC3090-Z RFID Mobile Computer Integrator GuideLLRP IconsThe LLRP icon indicates radio status as described in Table 3-1.LLRP MenuTap the LLRP icon to display the option menu shown in Figure 3-2.Figure 3-2    LLRP MenuTable 3-1     LLRP Icon IndicatorsIcon Icon State IndicationGreen LLRP is enabled.Crossed icon No radio connection or radio disconnected.Yellow Radio is reading at a lower power than set.Red Radio initiated Tx mute. This condition can occur when the battery is very low.
LLRP Functionality 3 - 3Configure LLRP LLRP is in Server Mode by default. To configure LLRP to operate in Client Mode:1. Tap the LLRP icon, then tap Configure LLRP.Figure 3-3    LLRP Configuration Window2. Select the Client Mode check box. 3. In the Server IP field, enter the server IP for the remote host to which LLRP communicates as a client.4. In the LLRP Port field, enter the port number on which the server waits for the LLRP client to communicate. The default is 5084.5. Select Apply.6. Select Exit to close the window, or Refresh to check the status of the connection.Version InformationTo view software version information for the LLRP application, tap the LLRP icon, then tap Version Info.Figure 3-4    LLRP Versions WindowThis window displays the LLRP server application version, RFID library version, radio firmware version, and radio OEM data version.NOTE The version information in Figure 3-4 may differ from the information on the actual mobile computer screen. Also, downloading data using LLRP scripts or the RFID_FLASH application updates the version information.
3 - 4 MC3090-Z RFID Mobile Computer Integrator GuideExit LLRPTap the LLRP icon, then tap Exit to close the LLRP application. To restart LLRP after exiting, use File Explorer to browse to the \Application\LLRP folder and tap the LLRP executable (OzoneLLRP.exe).LLRP Registry Entries RFID (LLRP) does not run when the MC3090-Z is charging. Developers who require using the cradle with RFID enabled can select Developer Mode by modifying a registry entry.•User Mode - In this default mode, placing the mobile computer in the cradle (with charging on) disables LLRP and the LLRP icon indicates that it is disconnected. Placing the mobile computer on AC power charges the device and disables LLRP. Removing AC power reconnects LLRP.•Developer Mode - Selecting Developer Mode disables charging and the developer can place the mobile computer in the cradle for debugging and development. The device remains in Developer Mode regardless of whether it is charging until re-enabling User Mode.To select Developer Mode via registry, set the DevMode registry entry value to 1:[HKEY_LOCAL_MACHINE\SOFTWARE\Symbol\RFID\Ozone]"DevMode"=dword:00000001Warm boot the device after registry merge and restart LLRP (if it is not already running).LLRP checks AC power every five seconds and takes the appropriate action based on whether or not it is in User Mode.
Chapter 4 RFID Sample ApplicationIntroductionApplication developers can use the RFID sample application RFIDSample3Plus.exe for an overview of how the application works and to assist in custom application development. The mobile computer can read, write, lock, kill, and program Gen2 tags. Each tag contains the EPC number (64 or 96 bits), CRC, and kill code. The mobile computer can also collect data by decoding in-range EPC Gen2 RFID tags.Initiating the read command within the sample application causes the mobile computer to interrogate all RFID tags within the radio frequency (RF) field of view. The reader captures data from each new tag and adds it to the list box in the EPC ID window. Select Stop Read to stop interrogating tags.
4 - 2 MC3090-Z RFID Mobile Computer Integrator GuideLaunching the RFID Sample ApplicationRemove the mobile computer from AC power and enable LLRP, then use File Explorer on the mobile computer to navigate to the Application folder. Select RFIDSample3Plus.exe to start the sample application. Figure 4-1    RFID Sample Application Window•Tap Menu to select the menu options. See Sample Application Menu Options on page 4-3.•Tap the Start Read button to initiate the tag read. Tap Stop Read to terminate tag reading. See Reading Tags on page 4-14. •Use the Mem Bank drop-down to select a tag memory bank to read. The default memory bank is EPC (None). Other options are TID, Reserved, and User.•Tap the note icon to generate an audio notification (beep) when the reader finds a new tag in the field of view.NOTE The version numbers displayed in this window are examples. Actual version numbers are based on the versions of the files on the device.
RFID Sample Application 4 - 3Sample Application Menu Options The Menu options include:•Configuration options•Operations options•Reader management options•AboutFigure 4-2    Sample Application MenuConfiguration Menu OptionsThe Config menu includes the following options:•Connection information•Configuration options•Capabilities •Reset Factory defaults •ExitFigure 4-3    Configuration Menu
4 - 4 MC3090-Z RFID Mobile Computer Integrator GuideConnectionSelect Config > Connection to display the reader IP and port number.Figure 4-4    Connection WindowSelect Disconnect to disconnect the reader.AntennaSelect Config > Configuration > Antenna to configure the antenna.Figure 4-5    Antenna Configuration WindowThis window includes the following fields:•Antenna - Selecting an antenna ID updates the configuration values in the other fields. •Receive Sensitivity(dB) - Lists the reader-supported values for the selected antenna.•Transmit Power - Lists the reader-supported values for the selected antenna. •Hop Index - Updates the Hop Frequency list with its corresponding frequencies. •Apply - Select to apply the configuration changes.
RFID Sample Application 4 - 5SingulationSelect Config > Configuration > Singulation to set the options for identifying an individual tag in a multiple-tag environment.Figure 4-6    Singulation WindowThis window includes the following fields:•Antenna - Selecting an antenna ID updates the configuration values in the other fields. •Session - The session number for the inventory operation.•Tag Transmit Time - The time in milliseconds that the tag typically remains in the RF field of the antenna.•Tag Population - The approximate tag population in the RF field of the antenna.•Inventory State - Select a tag of state A or B.•SL Flag •Apply - Select to apply the configuration changes.CapabilitiesSelect Config > Capabilities to retrieve the capabilities of the connected reader.Figure 4-7    Capabilities WindowSelect OK to close the window.
4 - 6 MC3090-Z RFID Mobile Computer Integrator GuideReset Factory DefaultsSelect Config > Reset Factory Defaults to restore the default reader configuration.Operations Menu OptionsThe Operations menu options include:•Tag Storage Settings•Filter options•Access options•Trigger settings•Antenna informationFigure 4-8    Operations MenuTag Storage SettingsSelect Operations > Tag Storage Settings to change the tag storage settings.Figure 4-9    Tag Storage WindowThis window includes the following fields:•Max tag count - The maximum number of tags to store in the DLL. •Max tag ID length - The maximum tag length.
RFID Sample Application 4 - 7•Max size of memory bank - Storage to allocate for the memory bank's data.•Apply - Select to apply the configuration changes.Filter SettingsUse the sample application’s filter settings to set filters for tag reading. The application supports up to two pre-filters and two post-filters. By default, the window displays the latest filter information. Add or delete the filter by selecting Use Filter. Pre-FilterTo select pre-filter settings, select Operations > Filter > Pre-Filter.Figure 4-10    Pre-Filter WindowThis window includes the following fields:•Antenna - Selecting an antenna ID updates the configuration values in the other fields. •Memory Bank - Select the memory bank.•Offset - The first (msb) bit location of the specified memory bank against which to compare the tag mask.•Tag Mask - The pattern against which to compare the specified memory bank.•Filter action - Select the required filter action. For more information, refer the Gen2 specification available at http://www.epcglobalinc.org/standards/.
4 - 8 MC3090-Z RFID Mobile Computer Integrator GuidePost-FilterTo select post-filter settings, select Operations > Filter > Post-Filter.Figure 4-11    Post Filter WindowThis window includes the following fields:•Match Pattern - Select the tag pattern to match (A, B, both, or neither). •Memory Bank - Select the memory bank.•Offset - The first (msb) bit location of the specified memory bank against which to compare the tag mask.•Bank Data •Tag Mask - The pattern against which to compare the specified memory bank.Access FilterTo select filter settings to apply to tags, select Operations > Filter > Access Filter.Figure 4-12    Post Filter WindowSee Post-Filter for descriptions of the window fields.
RFID Sample Application 4 - 9AccessSelect Operations > Access to select from a menu of access parameters to set for tags, or tap and hold a tag in the list to open a context menu with similar options in order to set operation parameters for that tag.Figure 4-13    Access and Context MenusSelecting an option from the context menu applies the operation to the single tag selected. Selecting an option from the Access menu updates the tag data for multiple tags in the main window. Select an option from the Access or context menu to set access parameters and the access filter. Figure 4-14    Read and Access Filter WindowsWindows are similar to the Read window in Figure 4-14 for the menu options Write, Lock, Kill, Block Write, and Block Erase. Set options as required in the various parameter windows. Not all windows include all options.•Tag ID - The name of the selected tag. •Password - Set a password before performing any access operation (except Kill).•Memory Bank - Select the memory bank. Options are:•Reserved•EPC•TID •User•Offset - Offset of the first word to read from the selected memory bank.
4 - 10 MC3090-Z RFID Mobile Computer Integrator Guide•Length - Tag/data length.•Write Data - The data to write to the selected tag (Write window only).•Lock Privilege - Access options for the selected tag (Write window only):•None - The can not change the lock privilege of the particular memory bank.•Read_Write - The user can read and write to the tag.•Perma_Lock - Permanent lock.•Perma_Unlock - Permanent unlock.•Unlock - The user can unlock the tag for writing.•Access Filter - Select this tab to set access filter parameters. See Post-Filter on page 4-8 for more information.TriggersSelect Operations > Triggers... to set start and stop triggers. Selecting the type of trigger from the Trigger drop-down menu updates the window with that trigger’s applicable parameters.Figure 4-15    Triggers WindowAntenna InformationSelect Operations > Antenna Info to select the antennas to use.Figure 4-16    Antenna Information Window
RFID Sample Application 4 - 11Management Menu OptionsThe Management menu provides access to reader management functionality such as updating firmware, selecting an antenna mode, and rebooting. The Management menu options include:•Login and Logout options•Reboot option•OEM Update option•Software/Firmware Update optionFigure 4-17    Management MenuLogin/Logout SettingsThe Reader Management functionality requires login authentication. Select Mgmt > Login/Logout... to log in or out of this functionality.Figure 4-18    Login WindowThis window includes the following fields:•Reader Type - MC indicates the MC3090-Z. •User name - Enter the user name used to gain access to reader management functionality.•Password - Enter the password used to gain access to reader management functionality.•IP - IP address of the host. For MC3090-Z, the default is 127.0.0.1 or localhost.
4 - 12 MC3090-Z RFID Mobile Computer Integrator GuideReboot SettingsSelect Mgmt > Reboot... to restart the reader.OEM UpdateSelect Mgmt > OEM Update to update the reader configuration file.Figure 4-19    OEM Update WindowEnter the Path Name indicating the location and name of the configuration file, and select Start Update.Software/Firmware UpdateSelect Mgmt > Software/Firmware Update to update the reader firmware software. First download the firmware update file to the mobile computer. See Downloading Firmware Files on page 2-2.Figure 4-20    OEM Update WindowEnter the Path Name indicating the location and name of the update file, and select Start Update.
RFID Sample Application 4 - 13AboutThe About window displays the sample application version informationFigure 4-21    About WindowNOTE The version numbers displayed in this window are examples. Actual version numbers are based on the versions of the files on the device.
4 - 14 MC3090-Z RFID Mobile Computer Integrator GuideReading TagsTo use the sample application to read tags:1. Aim the mobile computer at the tag, oriented horizontally or vertically depending on the tag orientation. The distance between the tag and the antenna is the approximate read range.Figure 4-22    RFID Tag Read2. Tap Start Read to interrogate all RFID tags within the radio frequency (RF) field of view, and capture data from each new tag found. Figure 4-23    RFID Tag ListThe sample application lists the following information for each tag read:•EPC ID - The data content of the tag.•RSSI - Received Signal Strength for the tag.•Count - The number of times the mobile computer read the tag.•Data Memory Bank - The memory bank data if you selected Reserved, TID, User, or EPC with offset.•MB - The selected memory bank (TID, RSVD, USER or EPC).Tap Stop Read to stop interrogating tags.
Chapter 5 TroubleshootingIntroductionTable 5-1 on page 5-1 provides the FX Series troubleshooting information.TroubleshootingTable 5-1    TroubleshootingProblem Possible Causes Possible SolutionsMobile computer does not turn on. Lithium-ion battery not charged.Charge or replace the lithium-ion battery.Lithium-ion battery not installed properly.Ensure battery is installed properly. Refer to the MC3000 Mobile Computer Integrator Guide.System crash. Perform a warm boot. If the RFID reader still does not turn on, perform a cold boot. Refer to the MC3000 Mobile Computer Integrator Guide.Rechargeable lithium-ion battery did not charge.Battery failed.  Replace battery. If the mobile computer still does not operate, try a warm boot, then a cold boot. Refer to the MC3000 Mobile Computer Integrator Guide.Mobile computer removed from cradle while battery was charging. Insert mobile computer in cradle and begin charging. The lithium-ion battery requires less than four hours to recharge fully.Mobile computer turns off without proper warning messages during heavy use.Due to component tolerances, this can occur when using battery part number 55-060112-xx.Use battery part number 55-002152-xx.No sound. Volume setting is low or turned off.Increase the volume setting.
5 - 2 MC3090-Z RFID Mobile Computer Integrator GuideTapping the window buttons or icons does not activate the corresponding feature.LCD screen not aligned correctly.Re-calibrate the screen.Battery is not inserted properly.Insert the battery properly. Refer to the MC3000 Mobile Computer Integrator Guide.A message appears stating that the mobile computer memory is full.Too many files stored on the mobile computer.Delete unused memos and records. Save these records on the host computer.Too many applications installed on the mobile computer.If additional applications have been installed on the RFID reader, remove them to recover memory.Tap Start > Settings > System tab > Remove Programs icon.Reader error LED lights after the reader has been in operation.The CPU cannot communicate.Refer to the system log for error messages.Reader error LED stays lit on power up.An error occurred during the power up sequence.Refer to the system log for error messages.Reader is not reading tags. The tag is out of its read range.Tags are damaged. Tags are not EPCgen2.Read application is not loaded.Move the tag into the read range. See Reading Tags on page 1-5.Use tags of good quality.Use EPCgen2 tags.Verify that the unit is loaded with a read application.Table 5-1    Troubleshooting (Continued)Problem Possible Causes Possible SolutionsNOTE If problems still occur, contact the distributor or call the local contact. See  page ix for contact information.
Appendix A  Technical SpecificationsTechnical SpecificationsThe following tables summarize the RFID reader intended operating environment and technical hardware specifications.Table A-1    Technical SpecificationsItem MC3090-Z RFIDPhysical and Environmental CharacteristicsDimensions  9.1 in. L x 3.6 in. W x 7.6 in. H23.1 cm L x 9.1 cm H x 19.3 cm HWeight 23 oz. / 650 g (includes battery, RFID, scanner, and radio)Keypad 48 keyTerminal Emulation (5250, 3270, VT)Display 3 in. 320 x 320 pixel colorBattery Extended capacity (2X) battery packPerformance CharacteristicsCPU Intel® XScale® Bulverde PXA270 processor at 624MHzOperating System Microsoft Windows Mobile 6.1Memory (RAM/ROM) 128 MB RAM/1 GB FlashApplication Development SMDKs available through the Support Web SiteData Capture Options Laser engine reads 1D and 2D symbologies with intuitive laser aiming.RFID reader reads Gen2 tags.
A - 2 MC3090-Z RFID Mobile Computer Integrator GuideLaser Decode Capability Code 39 Code 128 Code 93Codabar Code 11 Discrete 2 of 5Interleaved 2 of 5 EAN-8 EAN-13MSI UPCA UPCEUPC/EAN supplementals Coupon Code Trioptic 39Webcode RSS-14 RSS LimitedRSS Expanded EAN-128  TLC39Composite Code  PDF417  Micro PDF417Macro PDF417 MSI Plessey Maxi CodeData Matrix US Planet  UK 4-State Australian 4-State Canadian 4-State Japanese 4-StateDutch Kix Aztec USPS 4-State(US4CB)MicroQR User EnvironmentOperating Temperature -4°F to 122°F (-20°C to 50°C)Battery Charging Temperature32° to 104° F (0° to 40° C) ambient temperature rangeStorage Temperature -25°F to 160°F (-40°C to 70°C)Humidity 0% to 95% non condensingDrop Specification Multiple 6 ft. (1.8m) drops to concrete across operating temperature rangeTumble 2,000 one-meter tumbles at room temperature (4,000 hits)Environmental Sealing IP64 ESD +/-15kVdc air discharge+/-8kVdc direct discharge+/-8kVdc indirect dischargeRFIDStandards Supported EPC Generation 2 UHF Nominal read range110 ft./3.04 m with the RFX6000 4x4 tag optimally oriented.Field Half read range beam width: +/- 80 degrees (with tags optimally oriented).Antenna Integrated, circularly polarized, 1.5 dB effective linear gain per axis (nominal); Antenna port for future support of optional external antenna. Frequency Range 902-928 MHzOutput power 1W conducted (1.4W EIRP with integrated antenna)Wireless Data CommunicationsWLAN 802.11a/b/gOutput Power 100mW U.S. and InternationalTable A-1    Technical Specifications (Continued)Item MC3090-Z RFID
Technical Specifications A - 3Data Rate 802.11a: 54Mb per second802.11b: 11Mb per second802.11g: 54Mb per secondAntenna InternalFrequency Range: 802.11a: 5 GHz; country-dependent802.11b: 2.4 GHz; country-dependent802.11g: 2.4 GHz; country-dependentBluetooth Bluetooth® Version 1.2 with BTExplorer™ (manager) included Peripherals and AccessoriesCradles Single-slot availablePrinters Supports extensive line of Symbol approved printers, cables and accessoriesCharger 4-Slot universal battery chargerOther Accessories Cable Adapter Module; Magnetic Stripe Reader; Modem; Full set of holstersIn accordance with the SymbolPlus partner programRegulatoryElectrical Safety Certified to UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, IEC 60950-1.WLAN and Bluetooth® USA — FCC Part 15.247, 15.407; Canada — RSS-210.RF Exposure USA — FCC Part 2, FCC OET Bulletin 65 Supplement C; Canada — RSS-102.RFID USA — FCC Part 15.247, 15.205, 15.209: Canada — RSS-210.EMI/RFI USA — FCC Part 15; Canada — ICES-003.Table A-1    Technical Specifications (Continued)Item MC3090-Z RFID
A - 4 MC3090-Z RFID Mobile Computer Integrator GuideCable PinoutsUSB Client ConnectorThe USB Client port is supplied on a USB Type B connector.Figure A-1    USB Client ConnectorTable A-2     USB Client Port Connector PinoutPin Pin Name Direction DescriptionPin 1 5.0V_USB 1 5.0V USB Power Rail Pin 2 USB_DN I/O Data Negative RailPin 3 USB_DP I/O Data Positive RailPin 4 GND - Ground
Technical Specifications A - 5GPIO Port ConnectionsThese are plug terminal block types, allowing connecting and disconnecting individual wires independently. Separate connectors are used for inputs and outputs. See Table A-3 for pin descriptions.Figure A-2    FX Series RFID Reader GPIO ConnectionTable A-3    GPIO Pin OutsPin # Pin Name Direction Description1 +24V DC Power Input Supplies +24V DC at up to 1 Amp 2 GP output #1 Input Signal for GP output #13 GP output #2 Input Signal for GP output #24 GP input #1 Output Signal for GP input #15 GND Output Ground connection6 GP input #2 Output Signal for GP input #27 GND Output Ground connection1  2  3  4  5  6  7
A - 6 MC3090-Z RFID Mobile Computer Integrator Guide
Appendix B  RFID APIsFor information on supported RFID APIs, refer to the MC3090-Z RFID Enterprise Mobility Developer Kit.
B - 2 MC3090-Z RFID Mobile Computer Integrator Guide
IndexAactivesync  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1airbeam  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2antenna  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2, 1-3configuring   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-4information   . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-10APIs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1Bbattery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5-1, A-1battery charging temperature   . . . . . . . . . . . . . . . . . . A-2Ccable pinoutsGPIO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4charge LED indicator  . . . . . . . . . . . . . . . . . . . . . . . . .  1-4configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiconfiguring LLRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3connectionports   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4conventionsnotational   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiiCPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1Ddata capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  vii, A-1demo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-1access parameters  . . . . . . . . . . . . . . . . . . . . . . . 4-9antenna  . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4, 4-10configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-3connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-4filtering   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7firmware update  . . . . . . . . . . . . . . . . . . . . . . . .  4-12launching   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-2management . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-11menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-3OEM update  . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-12operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-6reader capabilities   . . . . . . . . . . . . . . . . . . . . . . .  4-5rebooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-12singulation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-5tag storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-6triggers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-10dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A-1display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A-1drop specification   . . . . . . . . . . . . . . . . . . . . . . . . . . .  A-2Eelectrical safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A-3Ffiltering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-7firmware update   . . . . . . . . . . . . . . . . . . . . . . . . 2-2, 4-12GGPIO pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A-5Hhumidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2IiconsLLRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-2image update   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1
Index - 2 MC3090-Z RFID Mobile Computer Integrator Guideactivesync  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-1airbeam  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-2update loader   . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1indicator LED bar . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-4Kkeypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  vii, A-1LLEDs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4, 1-5troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2LLRP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-1client mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-3configuring   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-3developer mode   . . . . . . . . . . . . . . . . . . . . . . . . .  3-4exiting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-4icons  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-2menu  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2registry entries   . . . . . . . . . . . . . . . . . . . . . . . . . .  3-4server mode   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3user mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-4version information  . . . . . . . . . . . . . . . . . . . . . . . 3-3Mmemory  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  vii, A-1OOEM update   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-12operating system  . . . . . . . . . . . . . . . . . . . . . . . . .  vii, A-1operating temperature  . . . . . . . . . . . . . . . . . . . . . . . . A-2PpinoutsGPIO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-4Rradio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii, 1-2reading tags . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5, 4-14problems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2reboot   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12registry updateLLRP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4regulatory standards  . . . . . . . . . . . . . . . . . . . . . . . . . A-3RFIDmenu  . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3, 4-6, 4-11settings  . . . . . . . . . . . . . . . . . . .  4-3, 4-6, 4-11, 4-13RFID APIs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1RFID components  . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2antennas  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2radio   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2tags  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2RFID demoreading tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14RFID firmware update  . . . . . . . . . . . . . . . . . . . . . . . . 2-2RFID overview  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Ssample application  . . . . . . . . . . . . . . . . . . . 4-1, 4-6, 4-12access parameters   . . . . . . . . . . . . . . . . . . . . . . . 4-9antenna  . . . . . . . . . . . . . . . . . . . . . . . . . . .  4-4, 4-10configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7launching  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2management  . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11menu  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3operations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6reader capabilities  . . . . . . . . . . . . . . . . . . . . . . . . 4-5rebooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12singulation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5triggers   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10scan buttons   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4scan LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4service information . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ixsingulation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . A-2support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ixTtag storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6tags   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7problems reading . . . . . . . . . . . . . . . . . . . . . . . . . 5-2reading   . . . . . . . . . . . . . . . . . . . . . . . . . . .  1-5, 4-14storage settings  . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6technical specifications   . . . . . . . . . . . . . . . . . . . . . . . A-1temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2triggers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10troubleshooting   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1Uupdating device  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1activesync  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1airbeam  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2firmware . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-2, 4-12OEM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12RFID firmware  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Index - 3update loader   . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1USBcable pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4port  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4Vvolume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1Wweight   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1WLAN 802.11a/b/g   . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Index - 4 MC3090-Z RFID Mobile Computer Integrator Guide
72E-125046-01 - Revision .2 - November 2009Motorola, Inc.One Motorola PlazaHoltsville, New York 11742, USA1-800-927-9626http://www.motorola.com/enterprisemobilityMOTOROLA and the Stylized M Logo and Symbol and the Symbol logo are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. © Motorola, Inc. 2009