Zebra Technologies WPT-3200 Proximity Communications Device User Manual Installation020921

Zebra Technologies Corporation Proximity Communications Device Installation020921

Contents

WherePort Installation Manual

Download: Zebra Technologies WPT-3200 Proximity Communications Device User Manual Installation020921
Mirror Download [FCC.gov]Zebra Technologies WPT-3200 Proximity Communications Device User Manual Installation020921
Document ID143377
Application IDoarQsnEk8gevznWqQDDFAA==
Document DescriptionWherePort Installation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize93.83kB (1172861 bits)
Date Submitted2001-04-05 00:00:00
Date Available2001-04-05 00:00:00
Creation Date2001-02-21 14:36:48
Producing SoftwareAcrobat PDFWriter 4.05 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleInstallation020921
Document CreatorMicrosoft Word
Document Author: Default

__________________________________________________________________________
Infrastructure Installation Guide
WHEREPORT INSTALLATION
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-1
__________________________________________________________________________
Infrastructure Installation Guide
Table of Contents
Page
WHEREPORT INSTALLATION
8.1
EQUIPMENT REQUIRED
8.2
SWITCH SETTINGS
8.3
POWER SUPPLIES
8.4
WIRING
8.5
MOUNTING
8.6
INDICATOR LIGHT
Table of Figures
Page
FIGURE 8-1
WHEREPORT SWITCH
FIGURE 8-2
POWER AND SIGNAL WIRING
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-2
__________________________________________________________________________
Infrastructure Installation Guide
WHEREPORT INSTALLATION
Every WherePort installation should be accompanied by a worksheet from the
responsible WhereNet Account Manager indicating required mounting location,
orientation and switch settings.
8.1
Equipment required
In addition to the WherePort(s) the following equipment is required:
•
AC power supply (see 8.3)
•
Interconnect power cable: Belden pn 9156
8.2
Switch settings
Removing the black rubber plug on the side of the WherePort gives access to the
switches. The one closest to the front is the power/phase switch; the one closest to
the metal heat sink is the ID switch. Set the switches according to the worksheet by
turning the arrowhead to point to the desired setting with a small straight screwdriver.
Replace the plug by applying pressure to the center of it until it seats.
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-3
__________________________________________________________________________
Infrastructure Installation Guide
Cove r
Pow er / P hase s w itc h
W he r eP or t ID sw itc h
Figure 8-1 WherePort switch
8.3
Power Supplies
The WherePort units require 24VAC at 250mA for operation. This is supplied by
transformer from either a 120VAC (US and Canada) or 230VAC (Europe) line.
Common wall mount transformers are recommended. Models available through
WhereNet are:
•
120 VAC for US/Canada: WhereNet P/N 20473
•
230 VAC for Europe: : WhereNet P/N 20474
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-4
__________________________________________________________________________
Infrastructure Installation Guide
These are both rated at 833mA so they can supply up to three WherePorts.
The WherePort can also be powered from DC. The DC is connected to the same
power wires as the AC; polarity doesn’t matter, the WherePort sorts it out.
Note: the metal heat sink will be common with the negative side of the DC supply.
Do not use a DC supply rated at a higher voltage than 36VDC.
8.4
Wiring
The cable pigtail from the WherePort contains three twisted pairs with functions as
follows:
•
White and Black: Power
•
Green and Black: Sync lines, connect to previous WherePort
•
Red and Black: Sync Lines, connect to next WherePort
____________
The black wires in the twisted pairs all carry a unique signal or power, they are
Note
not common within the unit so a miss-connection of them results in a non-
____________ functional unit.
____________
In locations subject to rain or spray, never mount the unit so that the pigtail points
upward and always dress the pigtail so it has a downward slope upon exiting the
WherePort housing.
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-5
__________________________________________________________________________
Infrastructure Installation Guide
Junction boxes are used for all connections. If using the recommended power
transformers outdoors, a NEMA rated box is recommended to house the
transformer. Power and sync connections are made by wire nuts appropriate for the
wire size. Belden Cable, part number 9156 or equivalent, is used to connect between
WherePort units and to remote transformers. It has two twisted pairs, a white and
black pair for connecting power and red and black pair for the sync connection
between units. The Sync lines are connected in a serial fashion. The red and black
twisted pair of one unit, connects to the red and black twisted pair in the cable
running between the units. This in turn connects to the green and black twisted pair
of the next unit, and so on. The sync lines can be used to connect up to nine
WherePorts together so their function is coordinated.
The power is feed in parallel using the white and black twisted pair. Care must be
taken not to exceed the rating of the transformer used for power. For example the
recommended transformers can support up to three WherePorts. Separate
transformers must be used to supply each set of three WherePorts. The circuit
distributing the power from one transformer is not permitted to connect to the circuit
distributing power from another transformer. The sync lines are permitted to connect
between WherePorts supplied by different transformers. The total length of the
twisted pair cable from any transformer to a WherePort shall not exceed 100 feet.
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-6
__________________________________________________________________________
Infrastructure Installation Guide
Wi r ing to W her eP ort
Rec ei ve si gnal s fr om
pr evi ous Wher e Por t on
gr een & b lac k w ir e pai r
Cabl e fr om pr evi ous
Whe re Por t or pow er
suppl y
Tr ans mi t si gna ls to
ne xt Wher eP or t on
r ed & bl ac k w ir e pai r
Cabl e to ne xt
Whe re Por t in cha in
Pow e r suppl y o n
w hit e and bl ack pa ir
Figure 8-2 Power and signal wiring
Applicable electrical and building codes shall be applied for supplying the line voltage
to the transformer.
8.5
Mounting
A bracket is supplied with the WherePort for mounting it to various supports with
180° of orientation adjustment on one axis. The desired placement and orientation is
included on the installation worksheet. The bracket is installed with screws or anchors
appropriate to the mounting material. Slots are provided in the bracket for mounting
to poles or pipes using band clamps or strapping. Stainless steal hardware is
recommended for all outdoor and wet installations. The bracket can be adjusted in
the distance the WherePort extends from mounting support by snapping off excess
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-7
__________________________________________________________________________
Infrastructure Installation Guide
bracket material at the break lines provided. Do not remove the material unless you
are sure the bracket will reach in the final mounting orientation.
The WherePort also has four standoffs built into the base that will accept ¼ inch
plastite thread forming screws. These allow mounting to any sheet material. A typical
application would be to mount them directly to the enclosure used to house the
transformer although care is required to get the proper orientation since this
eliminates the adjustable bracket.
8.6
Indicator Light
To verify correct wiring and operation, an indicator light visible through the window
on the front of the WherePort is provided. Upon the application of power, the light
will be amber and begin to blink. First it will blink the number of times equivalent to
the ID setting, then pause, blink the power setting, then pause and finally blink the
phase setting. After a moment, it will repeat the blink sequence. The ID blinks
directly correspond to the ID setting and the power/phase blinks are:
Number of Blinks
Power
Phase
0°
90°
180°
270°
After the amber blink sequence, the light will turn green if it is operating correctly,
red if not. A red indication can result from several different conditions:
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-8
__________________________________________________________________________
Infrastructure Installation Guide
•
Power supplied to the unit is insufficient for the power level setting. Check
connections and for proper power transformer or voltage.
•
Sync lines are miss-connected or shorted. Unused lines must not be connected to
anything, including each-other; used lines must be properly connected.
•
Too much metal surrounds the unit.
•
Unit has failed; very unlikely if it is new.
Settings can be changed while the unit is powered. If this is done, the indicator light
will turn amber and soon restart the blink sequence. Cycling power will also restart
the blink sequence.
___________________________________________________________________
WherePort Installation
 Copyright WhereNet Corp. 2001
WhereNet - Confidential
D0060 rev C
8-9

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 9
Creator                         : Microsoft Word
Create Date                     : 2001:02:21 14:36:48
Title                           : Installation020921
Author                          : Default
Producer                        : Acrobat PDFWriter 4.05 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NSQWPT-3200

Navigation menu