Zephyrlock 6000 ELECTRONIC RFID & KEYPAD LOCKS User Manual User manual
Zephyrlock,LLC ELECTRONIC RFID & KEYPAD LOCKS User manual
Users manual
6000 USER MANUAL ELECTRONIC RFID & KEYPAD LOCKS ZEPHYR LOCK 1. Summary 1.1 What are 6000 Locks? 6000 locks are the RFID and keypad integrated locker lock can operated by either RFID Cards or password keypads. Digital Button (0 – 9) Lock Button/Unlock Button Power Button 1.2 RFID Card Types and Functions Item Card Types Functions User Card Data Card Time Change Card Setup Card Management Card Control Card This card can open registered lock only Read the open lock record and lock information Setup lock clock Write preset functions into lock Open any lock does not clear the registered card/password Authorization Card ➊ Open any lock ➋ Clear registered card/password Authorize ELMS software and locks 1.3 Lock Operation System Composition Lock Operation System consisted of PC based Electronic Lock Management System (ELMS) software and RFID Card reader/writer, and enable the operator to issue User card, setting the lock information, lock status and to produce the statistical report. System Requirements: * OS: Windows XP/Windows7/Windows8/Windows10 * USB port for Card reader/writer interface 2. Operation Type 6000 Locker Locks are designed to work for the various operation requirements by simple setup process. Following operation modes can be programmed before or after lock installation. 2.1 Shared Use Mode 2.1.1 User can select any available locker 2.1.2 LED lamp to show the status of locks 2.1.3 Programmable to use multiple locks with one user card 2.1.4 Programmable for time based operation 2.2 Permanent Use Mode 2.2.1 Locker assigned to each user card in advance 2.2.2 Programmable to use multiple assigned lockers with one card 2.2.3 Programmable for multiple users per locker 3. Lock Operations 3.1 Shared Use Mode‐‐ Storage Personal belongings 3.1.1 User approaches the locker; locker door is open and no light is flashing, which means the locker is available 3.1.2 User opens the locker door; places device(s) inside the locker, then closes the door. 3.1.3 Presses the Power Button, Green LED starts flashing for 6 seconds, the lock is ready to accept user input by scan user RFID card or key code combination. 3.1.4 User then refocuses on the keypad and begins entering his own 4‐digit pass code. 3.1.5 As he presses the first number button, the green LED flashing turns off. 3.1.6 After the fourth number is entered, and presses the Lock Button within 5 seconds, 3.1.7 Motor will run the red LED flashes once and the user needs to turn the knob counterclockwise to lock the lock. 3.1.8 The red LED continues to flashing red, showing that the locker is in use. ‐‐ Take Personal belongings 3.1.9 User approaches the locker, press the Power Button and starts enter the 4‐digit pass code then press the Unlock Button. 3.1.10 Red LED turns off, motor will run to release the knob and the user needs to turn the knob clockwise to unlock the lock. 3.1.11 User opens the locker door and takes out his personal belongings then walk away, keep the locker door open. 3.1.12 The locker is now available for the next user. 3.2 Permanent Use Mode 3.2.1 User approaches the locker; locker door is closed and no light is flashing, which means the locker is only available for Permanent Use. 3.2.2 User pushes the Power Button and swipes registered User Card. 3.2.3 Green LED starts flashing motor will run to release the knob and the user need to turn the knob clockwise to unlock the lock. 3.2.4 User opens the locker door within 3 seconds, places (or takes) Personal belongings then closes the locker door. The motor turns again after 3 seconds and the user need to turn the knob counterclockwise to lock the lock. 3.2.5 All LED turns off showing that the locker is in use. 4. Lock Setting and Emergency open 4.1 Lock Setting 4.1.1 Use the ELMS software to pre‐set the lock’s function, then issues Cards. 4.1.2 Swipe the Authorization Card. 4.1.3 Swipe the Setup Card, Lock setting is now completed. 4.2 Emergency open In case user forgot the password, or lost his User card 4.2.1 Operator can swipe the Management Card to open the lock. 4.2.2 Or swipe the Control Card to open the lock. Note: If the lock worked in Shared Use mode, after swiped the Control Card, the registered card / password will be clear 5. Indication of sound and light 5.1 Shared Use Mode Operations 5.1.1 All the pass code is 4‐digit 0 – 9. 5.1.2 Key tone: 1 short beep. 5.1.3 Unlock or Lock : 1 short beep. 5.1.4 Less than 4‐digit are entered presses Lock Button: 4 short beeps. 5.1.5 More than 4‐digit are entered presses Lock Button: 3 short beeps. 5.1.6 Available status: No LED lights. 5.1.7 In use status: Red LED flashes. 5.1.8 Power Button: 1 short beep, green LED flashing 5 seconds. 5.2 Permanent Use Mode operations 5.2.1 Swipe User Card: 1 short beep, green LED flashing once. 5.2.2 Swipe Management Card: 1 short beep, green LED flashing 5 seconds. 5.2.3 Swipe Control Card: 1 short beep, green LED flashing 5 seconds. 5.2.4 Swipe Data Card: Start Reading: 1 short beep, Finish Reading: 2 short beeps, green LED flashing. 5.2.5 Swipe Time Change Card: 2 short beeps. 5.2.6 Swipe Setup Card: 2 short beeps. 5.2.7 Swipe Authorization Card: 1 short beep. FCCInformationandCopyright ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcan radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions, maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipment offandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: —Reorientorrelocatethereceivingantenna. —Increasetheseparationbetweentheequipmentandreceiver. —Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. —Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeused inportableexposureconditionwithoutrestriction. FCC-ID:XLY-6000
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : ntek138 Create Date : 2017:06:21 14:51:54+08:00 Modify Date : 2017:07:13 11:39:26+08:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Producer : Acrobat Distiller 9.0.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:07:13 11:39:26+08:00 Format : application/pdf Title : Microsoft Word - User manual Creator : ntek138 Document ID : uuid:59634b09-e9ce-48ff-b63a-e6beedfcda60 Instance ID : uuid:be8a768d-1415-4345-9e7f-db56d0ead86f Page Count : 7EXIF Metadata provided by EXIF.tools