Zephyrlock 6000 ELECTRONIC RFID & KEYPAD LOCKS User Manual User manual

Zephyrlock,LLC ELECTRONIC RFID & KEYPAD LOCKS User manual

Users manual

Download: Zephyrlock 6000 ELECTRONIC RFID & KEYPAD LOCKS User Manual User  manual
Mirror Download [FCC.gov]Zephyrlock 6000 ELECTRONIC RFID & KEYPAD LOCKS User Manual User  manual
Document ID3468004
Application IDbly97XjEMb2SJYpTC40MnQ==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize23.38kB (292197 bits)
Date Submitted2017-07-17 00:00:00
Date Available2017-07-17 00:00:00
Creation Date2017-06-21 14:51:54
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-07-13 11:39:26
Document TitleMicrosoft Word - User manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: ntek138

6000 USER MANUAL
ELECTRONIC RFID & KEYPAD LOCKS
ZEPHYR LOCK
1. Summary
1.1 What are 6000 Locks?
6000 locks are the RFID and keypad integrated locker lock can operated by either RFID Cards or
password keypads.
Digital Button (0 – 9)
Lock
Button/Unlock
Button
Power Button
1.2 RFID Card Types and Functions
Item
Card Types
Functions
User Card
Data Card
Time Change Card
Setup Card
Management Card
Control Card
This card can open registered lock only
Read the open lock record and lock information
Setup lock clock
Write preset functions into lock
Open any lock does not clear the registered card/password
Authorization Card
➊ Open any lock ➋ Clear registered card/password
Authorize ELMS software and locks
1.3 Lock Operation System Composition
Lock Operation System consisted of PC based Electronic Lock Management System (ELMS) software and
RFID Card reader/writer, and enable the operator to issue User card, setting the lock information, lock
status and to produce the statistical report.
System Requirements:
* OS: Windows XP/Windows7/Windows8/Windows10
* USB port for Card reader/writer interface
2. Operation Type
6000 Locker Locks are designed to work for the various operation requirements by simple setup process.
Following operation modes can be programmed before or after lock installation.
2.1 Shared Use Mode
2.1.1 User can select any available locker
2.1.2 LED lamp to show the status of locks
2.1.3 Programmable to use multiple locks with one user card
2.1.4 Programmable for time based operation
2.2 Permanent Use Mode
2.2.1 Locker assigned to each user card in advance
2.2.2 Programmable to use multiple assigned lockers with one card
2.2.3 Programmable for multiple users per locker
3. Lock Operations
3.1 Shared Use Mode‐‐ Storage Personal belongings
3.1.1 User approaches the locker; locker door is open and no light is flashing, which means the locker is
available
3.1.2 User opens the locker door; places device(s) inside the locker, then closes the door.
3.1.3 Presses the Power Button, Green LED starts flashing for 6 seconds, the lock is ready to accept user
input by scan user RFID card or key code combination.
3.1.4 User then refocuses on the keypad and begins entering his own 4‐digit pass code.
3.1.5 As he presses the first number button, the green LED flashing turns off.
3.1.6 After the fourth number is entered, and presses the Lock Button within 5 seconds,
3.1.7 Motor will run the red LED flashes once and the user needs to turn the knob counterclockwise to
lock the lock.
3.1.8 The red LED continues to flashing red, showing that the locker is in use.
‐‐ Take Personal belongings
3.1.9 User approaches the locker, press the Power Button and starts enter the 4‐digit pass code then
press the Unlock Button.
3.1.10 Red LED turns off, motor will run to release the knob and the user needs to turn the knob
clockwise to unlock the lock.
3.1.11 User opens the locker door and takes out his personal belongings then walk away, keep the
locker door open.
3.1.12 The locker is now available for the next user.
3.2 Permanent Use Mode
3.2.1 User approaches the locker; locker door is closed and no light is flashing, which means the locker is only
available for Permanent Use.
3.2.2 User pushes the Power Button and swipes registered User Card.
3.2.3 Green LED starts flashing motor will run to release the knob and the user need to turn the knob clockwise to
unlock the lock.
3.2.4 User opens the locker door within 3 seconds, places (or takes) Personal belongings then closes the locker
door. The motor turns again after 3 seconds and the user need to turn the knob counterclockwise to lock the lock.
3.2.5 All LED turns off showing that the locker is in use.
4. Lock Setting and Emergency open
4.1 Lock Setting
4.1.1 Use the ELMS software to pre‐set the lock’s function, then issues Cards.
4.1.2 Swipe the Authorization Card.
4.1.3 Swipe the Setup Card, Lock setting is now completed.
4.2 Emergency open
In case user forgot the password, or lost his User card
4.2.1 Operator can swipe the Management Card to open the lock.
4.2.2 Or swipe the Control Card to open the lock.
Note: If the lock worked in Shared Use mode, after swiped the Control Card, the registered card
/ password will be clear
5. Indication of sound and light
5.1 Shared Use Mode Operations
5.1.1 All the pass code is 4‐digit 0 – 9.
5.1.2 Key tone: 1 short beep.
5.1.3 Unlock or Lock : 1 short beep.
5.1.4 Less than 4‐digit are entered presses Lock Button: 4 short beeps.
5.1.5 More than 4‐digit are entered presses Lock Button: 3 short beeps.
5.1.6 Available status: No LED lights.
5.1.7 In use status: Red LED flashes.
5.1.8 Power Button: 1 short beep, green LED flashing 5 seconds.
5.2 Permanent Use Mode operations
5.2.1 Swipe User Card: 1 short beep, green LED flashing once.
5.2.2 Swipe Management Card: 1 short beep, green LED flashing 5 seconds.
5.2.3 Swipe Control Card: 1 short beep, green LED flashing 5 seconds.
5.2.4 Swipe Data Card: Start Reading: 1 short beep, Finish Reading: 2 short beeps, green LED flashing.
5.2.5 Swipe Time Change Card: 2 short beeps.
5.2.6 Swipe Setup Card: 2 short beeps.
5.2.7 Swipe Authorization Card: 1 short beep.

FCCInformationandCopyright
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,
pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection
againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcan
radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,
maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful
interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipment
offandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
—Reorientorrelocatethereceivingantenna.
—Increasetheseparationbetweentheequipmentandreceiver.
—Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris
connected.
—Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement.Thedevicecanbeused
inportableexposureconditionwithoutrestriction.
FCC-ID:XLY-6000

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : ntek138
Create Date                     : 2017:06:21 14:51:54+08:00
Modify Date                     : 2017:07:13 11:39:26+08:00
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:07:13 11:39:26+08:00
Format                          : application/pdf
Title                           : Microsoft Word - User  manual
Creator                         : ntek138
Document ID                     : uuid:59634b09-e9ce-48ff-b63a-e6beedfcda60
Instance ID                     : uuid:be8a768d-1415-4345-9e7f-db56d0ead86f
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XLY-6000

Navigation menu