Zhuhai Unitech Power Technology DNYS-2C Smart key User Manual

Zhuhai Unitech Power Technology Co., Ltd. Smart key

User Manual

Download: Zhuhai Unitech Power Technology DNYS-2C Smart key User Manual
Mirror Download [FCC.gov]Zhuhai Unitech Power Technology DNYS-2C Smart key User Manual
Document ID2456965
Application ID8y2A0njyhd6RL6PxRFI1ng==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize46.56kB (581940 bits)
Date Submitted2014-11-26 00:00:00
Date Available2014-11-26 00:00:00
Creation Date2014-11-18 10:19:40
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2014-11-21 17:42:37
Document Titleuntitled

Confidentiality: ■ O open
□ S Confidential
□ TS Confidential
Document Category: R & D Doc
Document Number: UM‐DNYS2C‐002
Version: V1.00
DNYS‐2C smart key
Operating Manual
Total 30 pages
Zhuhai Unitech Power Technology Co., Ltd.
OCT 20, 2014
Approval for Documents:
Department / Position
Date
Signature
Prepared by
Product development / software engineer
Lu Haijiang, Tan
Yi
2014.10.20
Checked by
R & D Management Department /RQA
Xu Lan
2014.10.20
Verified by
Structure Department / Project Manager
Yin Xuewen
2014.10.20
Countersigned by
Hardware
Department
representative
hardware
Chen Pengzhi
2014.10.20
Countersigned by
Structure
Department
Representative
Structure
Li Qiping
2014.10.20
Countersigned by
ProductDevelopment
Department
Software Representative
Tan Yi
2014.10.20
Approved by
Product Planning Department / product
manager
Xiu Hongjiang
2014.10.20
Document Revision History:
Version
Summary of modification
Modified by
Approved by
Effective date
1.00
Initial version
Lu Haijiang
Xiu Hongjiang
2014.10.20
Copyright
The copyright of the DNYS‐2C MiniSmart Key Operating Manual is owned by Zhuhai Unitech
Power Technology Co., Ltd. No part of the Manual shall be copied or disseminated in any form by
any means, electronically or mechanically, including photocopying or recording, or for any
purpose, without written permission of Zhuhai Unitech Power Technology Co., Ltd.
(c)Copyright 2014 Zhuhai Unitech Power Technology Co., Ltd.
All rights reserved.
is a registered trademark of Zhuhai Unitech Power Technology Co., Ltd.
Guide
READING GUIDE
Manual Objective:
The Manual mainly provides operating instructions on DNYS‐2C Smart Keys and auxiliary
iAdapterE-1 transmission adapter and iCDZE-1 recharge stand products supplied by Zhuhai
Unitech Power Technology Co., Ltd. To enable product users to have a basic understanding
of product functions, performance and characteristics and grasp product operating and
maintenance methods.
Audience:
The Manual, prepared for DNYS‐2C Smart Key users, mainly includes contents such as
operation, parameter settings and production maintenance, and is mainly to provide the
operating method of this product for operators.
Structure:
This Manual contains the following contents: general information and features are introduced in
the first chapter. Product installation and precautions are described in the second chapter. The
appearance and basic operations, as well as each menu to be operated by users are described in
the third chapter. The defaulting parameter settings are introduced in the fourth chapter. Display
information and data during using process are described in the fifth chapter. The sixth chapter
describes the product maintenance and troubleshooting methods.
Conventions:
The manual complies with the following conventions:
1 All the menus come with “”;
2 All references adopt Italic;
“NOTE” means the matters requiring readers to pay attention.
“WARNING” means the matters that may cause serious errors and must be attended.
Foreword
The products are mainly used in power industry interlock by foreign terminals, such as
substations, power plants, etc. It is capable to receive operating orders from Smart interlock hosts,
and then to operate all kinds of locks in strict operating orders. In Smart interlock system, the
smart key is used as a handheld device between the host and device on site, and regarded as one
of the most critical system components. This product is developed base on the company's existing
key, which integrates current new technologies on the market, and satisfies the needs of users,
thus to have powerful competitiveness of the Smart interlock system market.
Warning: Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
● Consult the dealer or an experienced radio/TV technician for help.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
Table of Contents
CHAPTER 1 OVERVIEW ......................................................................... 1
1.1 INTRODUCTION ............................................................................. 1
1.2 SCOPE OF APPLICATION .................................................................... 1
1.3 FUNCTIONS AND FEATURES ................................................................ 1
1.4 MODEL AND CONFIGURATION ............................................................ 2
CHAPTER 2 INSTALLATION .................................................................... 2
2.1 INSTALLATION STEPS ....................................................................... 2
2.2 INSTALLATION CAUTIONS .................................................................. 2
CHAPTER 3 OPERATION ........................................................................ 3
3.1 DISPLAY PANEL .............................................................................. 3
3.2 OPERATIONS ................................................................................ 4
3.2.1 Basic operations .................................................................. 4
3.2.2 Synchronization ................................................................... 5
3.2.3 Receive Operation Orders ..................................................... 6
3.2.4 Unlock ................................................................................ 7
3.2.5 Post Back .......................................................................... 15
3.2.6 Browse orders ................................................................... 16
3.2.7 Function ........................................................................... 17
3.2.8 Settings ............................................................................ 19
3.2.9 About ............................................................................... 26
CHAPTER 4: PARAMETER SETTINGS .....................................................27
4.1 AUTO POWER‐OFF ....................................................................... 27
4.2 AUTO SLEEP MODE ....................................................................... 27
4.3 INTERFACE BRIGHTNESS ................................................................. 27
4.4 DISPLAY L ANGUAGE ...................................................................... 27
4.5. INTERFACE THEMES ...................................................................... 27
4.6 SPEAKER STATUS .......................................................................... 27
4.7. RECORDING FUNCTION .................................................................. 27
4.8 AUDIO COMPRESSION .................................................................... 27
CHAPTER 5 DISPLAY DESCRIPTIONS .................................................... 28
CHAPTER 6 PRODUCTS MAINTENANCE............................................... 29
6.1 UPGRADE MAINTENANCE ................................................................ 29
6.2 ROUTINE MAINTENANCE................................................................. 29
6.3 TROUBLESHOOTING ...................................................................... 29
Chapter 1 Overview
1.1 Introduction
DNYS‐2C smart key is a new type of OLED color‐screen smart key based on the “Double‐less” technology of the
company, based on our application and development experience over the years, which can be operated in
conjunction with JOYO series of microcomputer safety interlock systems. The “Double‐less” technology is a new
acquiring and coding technique developed by the company under huge investments, which has gained many
patents and is especially applicable to the Smart interlock field, characterized by limitless coding and wireless
acquiring.
The DNYS‐2C smart key has been essentially upgraded and improved, no matter in technology, performance, and
manufacture process, compared with the previous type of smart keys, and it is capable of meeting the customer’s
new requirements on interlock devices such as the applications in centralized control station.
1.2 Scope of application
Applicable to intetlock of substations, power plants, etc.
1.3 Functions and features
The product has the following functions and features:
9 Limitless coding; and the coding system adopts the GUID;
9 Wireless code acquiring; the smart key adopts the non‐contact acquisition mode.
9 “Black Box” function: Recording and browsing the operation orders and the operation information; the data
can be well saved within 10 years after power‐off;
9 The smart key functions as order clearance, synchronization, memory, lock code checking, termination of the
current operation order, step‐skipping, real‐time clock, battery electric quantity detection, self‐diagnosis, etc.
9 It can release and detect various locks as follows:
‹
Mechanical coding lock
‹
fixed program lock
‹
Electric cording lock
‹
Locking box
‹
Electroscope
‹
State detector
‹
High‐voltage presence indicating systems
The system is provided high‐speed data transmission module such as high‐speed infrared IRDA module.
Voice prompt in English;
9
Available in recording function, equipped with large‐capacity recording & storage device, available to be
selected according to needs.
OLED color screen to enhance the visual effects.
High‐contrast, multi‐line Chinese character display.
OLED screen, adjustable display brightness, thus to meet the needs of different users.
Friendly interface, easy to use, simple.
Intelligent power management technology, automatic detection of battery failure, thus to ensure the
system is running at low power consumption and extends battery life.
Lithium‐ion battery, with built‐in design.
Compatible with Chinese characters & English characters under GBK encoding standards
Super capacity memory; expandable as needed;
Developed based on the Real‐Time Operating System (RTOS); high stability; convenient extension;
Integrated mechanism and overall metal frame design to enhance its fall resistance and impact
resistance;
Brand new structure integrating functions such as code acquisition, detection, and releasing mechanical
lock, for a simple and convenient operation and the improvement on the stability, reliability, and
productbility.
1.4 Model and configuration
Product Name: smart Key
Model: DNYS‐2C
Chapter 2 Installation
2.1 Installation Steps
Handheld standalone product, no needs in on‐site installation; available to be placed directly on the adapter
2.2 Installation cautions
1. When it is being placed on the adapter, please ensure the adapter needles are properly contacted with charging
contacts.
2. Placement: when the smart key is not in service, please place the smart key in a fixed place, rather than random
places.
3. Do not place the smart key in any specially wet environment in a long term, to extend the service life of the
smart key.
4. The smart key is product integrating machinery, optic, and electric technologies, with a complex internal
structure, except as authorized by its manufacturer, please do not disassemble to avoid any damage to internal
components.
5. Please keep its data transmission ports clean, to avoid any damage to data transmission performance.
6. Smart key is a precision power handheld devices; please avoid damage and abnormality resulting from strong
shock or falling.
Chapter 3 Operation
3.1 Display Panel
1‐‐‐‐‐‐‐ Release rod: release the mechanical coding lock, or other locks;
2 ‐‐‐‐‐‐‐ Disk, determining the rotating direction of release rod in unlocking.
3 ‐‐‐‐‐‐‐ Conductive electrode, powering on locks needing external power supply.
4‐‐‐‐‐‐‐ OLED color screen: displaying the operation information by characters and graphics information;
5‐‐‐‐‐‐‐ Keys, including the Return key (the Switch on/off key), the Up key, the Down key, and the Enter key
6‐‐‐‐‐‐‐ Speaker and phonic hole;
7 ‐‐‐‐‐‐‐ MiC microphone for recording.
8 ‐‐‐‐‐‐‐ Infrared tube communication interface.
9 ‐‐‐‐‐‐‐ USB data line interface.
10 ‐‐‐‐‐‐ Charging electrode contacting with the charging mount.
11 ‐‐‐‐‐‐ High speed infrared IRDA transmission device for exchanging data with mis‐operation prevention hosts.
3.2 Operations
3.2.1 Basic operations
¾
Power‐on
(1) Ensure that the smart key is available to be powered. If the battery runs low, the smart key can’t start, please
operate in accordance with the second step. When the power is enough, please operate in accordance with the
third step.
(2) Place the smart key on the charger and check if it is properly placed and is stably connected to the charger.
(3) Press the on / off key on the panel, and then release it, the smart key produces “Beep” sound and displays the
dynamic LOGO on the interface, and shows the following standby interface later:
Thereinto:
z“
“ is a symbol of battery, indicating the current running level of the battery, the full‐green color indicates
that the battery runs in full level; the full‐black color indicates that the battery runs out. When the battery symbol
is empty, indicates the battery runs out, please charge the battery immediately. “
“icon indicates smart key’s
current communication mode, the above icon means IRDA communication mode.“
”icon indicates the current
voice state, and availability in playing voice. The above figure shows enablement state of the function, and “
”
shows disablement state. See specific setting method in the “Settings” ‐> “VoiceFunc” ‐> “SetVoice” as described
in 3.2.8 Voice Settings.
¾
Power‐off
It is available to close the smart key at any state after starting. A user can press and hold down the On / Off key on
the panel for about 2 seconds, the smart key produces the sound “beep…beep…”, then the user can release the key,
the key can switch off the power supply automatically.
¾
Preparation before Operation
The smart key is a general‐purpose smart key, which can be applied to any station, and it is required to enable the
“Sync” function before operation, thus to transmit the station's device information to the smart key. If the device
information is not modified in a station, the smart key can be used forever as long as enabled “Sync”.
¾
Menu Operation
In the standby interface, press the “Menu” key to enter main menu: Then press the UP or Down keys to browse the
whole main menu, as shown below:
Thereinto:
z The “Receive” is the default option on the menu, indicating the option is selected. Now a user presses the Down
key to select the next option on the menu, similarly, it is available to press the Up key to select the previous option.
z When selecting an option on the menu, press the Enter key to enter the function menu interface or the
submenu interface; press the Cancel key to the standby interface or the option's parent menu.
z When a user operates on a submenu, it can display the scroll bar icon on the right side of the screen, to show
the current position of the selected submenu.
3.2.2 Synchronization
The smart key features good interchangeability and versatility, it can be applicable to different substations or
power plants once successfully synchronized before the first operation.
It is available to receive synchronous data directly in the standby interface, or select “Function” on the main menu,
and then select the “Sync” option to directly enter the synchronous interface; the smart key can receive the
synchronous data atomically.
Thereinto:
z Press the Return key to the previous menu。
When the key is being charged on the transmission adapter, the key can receive synchronous data if the user sets
host system to the synchronous state, and the smart key enters the synchronous interface.
When the key starts receiving synchronous data, it can display the following interface, the progress bar shows the
receiving progress of synchronous data.
When the synchronous data have been received, the smart key is capable of processing and saving the received
data.
3.2.3 Receive Operation Orders
A user can press the Upward or Downward key to select the option “Receive” on the main menu, and press Enter;
it can enter the order‐receiving interface. Then Smart Key can enter order‐receiving interface directly.
Thereinto:
z If the key hasn’t synchronized, it can not enter the order‐receiving interface, the screen displays the information
“Without sync, cannot receive order”, and a user must conduct synchronization before receiving orders.
z Press the On / Off key to the main menu.
When the key is being charged on the transmission adapter, the key can receive orders if the user sets host system
to the order‐sending state, and the smart key enters the order‐receiving interface.
When the key starts receiving order data, it can display the following interface, the progress bar shows the
receiving progress of order data.
When the smart key has processed and saved the received data, the key can switch to the following operating
interface automatically.
A user can operate on site now in accordance with the displayed content.
3.2.4 Unlock
Unlock the Devices Locked by Mechanical Coding Locks Such as Manual Disconnector, Grounding‐switch, and
Temporary Grounding Connector Locking Box
The smart key can display the specific device information under operating while unlocking the mechanical coding
locks such as manual disconnector, grounding‐switch, and temporary grounding connector, web door, etc. For
example, if a user wants to “61E line: Open Breaker”, the key can display the following information at this moment:
Find the corresponding device matched with the displayed by the key on site, and insert the smart key into the
keyhole, if the code is correct, the smart key can ring “beep” or make a voice prompt “Correct, Please Operate.”
(Available to set in the system) and display as follows:
Rotate the smart key to open the mechanical coding lock at this moment and then switch.
When the correct operation is completed, the smart key can ring “beep” and prompt “Operation finished”
Then the operator can continue the next operation.
Note: for exmaple, in “Confirm 61E Breaker operation”, if the inserted lock’ code is not consistent with the
displayed in the key, the key can ring “beep” three times or make a voice prompt “Error, Please Check.” (Available
to set in the system) and display below, the above is the same to other types of locks.
At this moment, the operator can’t unlock because the interlocking gear is locked. Please pull out the key and find
the correct code before continuing.
Unlock the Devices Interlocked by Electric Coding Locks Such as Circuit Breaker, Electric Disconnector, etc.
When the smart key displays the device information of circuit breaker or electric disconnector, such as “74E line:
Open Breaker”, please insert the smart key into the electric coding lock of corresponding device, it can ring “beep
“ or prompt by voice “Correct, Please Operate.” (Available to set in the system) and display “Correct Code, Please
Operate!”
Switch the breaker at this moment, the key rings “Beep” and displays “the operation is completed, please
continue!” indicating that the key has detected the completion signal. It is available to unplug the smart key and
continue.
If the key is unplugged when it has not detected the complete operation signal within 2 seconds under the
operation of electric coding lock, it can show as below:
Press and hold down the “success” or “failure” key (for 2 seconds) to select the operating results, “success”
indicates that this step is complete, the key can enter the next step; “failure” indicates that this step is not
completed and will be restarted.
If the key is unplugged when it has not detected the complete operation signal over 2 seconds under the operation
of electric coding lock, it can show as below:
Press and hold down the “success” or “failure” key ( for 2 seconds) to select the operating results, “success”
indicates that this step is complete, the key can enter the next step; “failure” indicates that this step is not
completed and will be restarted.
Unlock the Devices Interlocked by Electric Coding Lock and Mechanical Coding Lock Such as Electric
Disconnector.
When the smart key displays the information of the devices to be operated, please insert the smart key into the
electric coding lock or mechanical coding lock of corresponding device, it can ring “beep…” or prompt by voice
“Correct, Please Operate!” (Available to set in the system) and display “Correct Code, Please Operate.”
A user can operate electric coding lock or mechanical lock as needed, then the user chose to insert the mechanical
locks and Rotate the smart key to unlock, the smart key rings “beep” and displays the following information:
It indicates that the smart key has completed its working; the user can remove the smart key and continue the next
operation.
While inserting the corresponding electric coding lock, it is available to operate in accordance with the steps
described in “3.4.2 Unlock the Devices Interlocked by Electric Coding Locks Such as Circuit Breaker, Electric
Disconnector, etc.”
z State Detection
The smart key shows the state of the device to be detected, please find the corresponding connection or
disconnection state detectors, electrical switching state detectors in accordance with the device number shown on
the smart key, and insert the smart key; the smart key can continue its working only after detecting the correct
state. Take Confirm 81E Breaker in close position as an example.
Insert the key into corresponding locks, if code value is wrong, the smart key will beep for continuous three times,
or even prompt a voice “Error, please check.” If the code value is correct, the smart key will further determine the
status of locks and prompt detecting status:
10
z
Electriferous Detection(electroscope, high‐voltage live locking device)
Insert the smart key into the corresponding electroscope for further electriferous detection, when the smart key
displays electriferous detection and the next option.if the electriferous detection is correct, and the operation is
successful, it is available to enter the next step.
Taking “Verified that 73E Breaker has no voltage” as an example:
When the smart key displays the following information in the detecting process:
11
And produces rapid alarm sound “Beep…Beep…Beep…”indicating the circuits are electriferous, and can’t enter the
next operation.
When the smart key displays the following information, and rings “Beep,” it indicates that the circuits aren’t
electriferous, remove the smart key from the electroscope and enter the next operation.
Lock disconnectors and related equipments with fixed program lock
Locking disconnectors and related equipments with fixed program is mainly divided into three cases according to
fixed program lock specific types. Firstly, the fixed program locks can be divided into three types: the first type is
fixed program lock (one‐way lock), unlock and then lock; the second type is one‐way fixed program lock (one‐way
lock), unlock or lock; the third type is fixed program lock (two‐way lock).
As for the first type, fixed program lock (one‐way lock), taking “62E Line: Open Breaker” as an example. Insert the
key into the fixed program lock, until the smart key beeps and prompts “Correct, please operate” (available in
system settings); and it displays as follows:
Rotate the smart key to unlock; the smart key prompts the following interface after unlocking is successful; then it
is available to operate related devices:
12
After operation is completed, please lock as prompted by the smart key; insert the smart key. When it prompts the
lock code is correct, rotate the smart key to lock:
The above is operation steps for the first type of fixed program lock.
Secondly, as for one‐way fixed program lock (one‐way lock), taking “62E Line: Open Breaker” as an example. Insert
the key into the fixed program lock, until the smart key beeps and prompts “Correct, please operate” (available in
system settings); and it displays as follows:
Rotate the smart key to unlock; the smart key prompts the following interface after unlocking is successful; then it
is available to operate related devices:
The above is operation steps for the second type of fixed program lock.
13
Thereinto:
The operating procedures for the second type are only half of the first type’s. the whole operation can be
completed only after unlocking or locking ends.
Finally, as for the third type of fixed program lock (two‐way locking), such fixed program lock requires four code
values, which are twice more than the first two locks’, respectively connecting fixed program locks unlocking code;
connecting fixed program locks locking code; disconnecting fixed program locks unlocking code; disconnecting fixed
program locks locking code. Take “62E Line: Open Breaker” as an example. Insert the key into the fixed program
lock, until the smart key beeps and prompts “Correct, please operate” (available in system settings); and it displays
as follows:
In unlocking process of Close Breaker, the first step is disconnecting unlocking, after the lock code is verified as
correct, please rotate the key to unlock:
When the disconnecting unlocking is successful, unplug the smart key, and the key prompts:
Operate corresponding switching devices, and after the operation is successful, insert the smart key to lock
connecting position. After the lock code is verified as correct, please rotate the key to lock:
14
The above is operation steps for the third type of fixed program lock.
The third category of fixed program lock operation is complete.
Thereinto:
As for the third type of fixed program lock, its unlocking is similar with the first type’s, the only difference is that
the third type of fixed program lock operates twice on two fixed program locks on the same device, while the first
type operates a fixed program lock.
Open Breaker’s operation is similar with Close breaker’s, and the difference is only lock order and operation,
connecting unlocking is firstly done, and then the disconnecting locking is performed.
3.2.5 Post Back
The data postback is a transmission process of the operation processes and results and other information from the
smart key to the mimic panel, (or integrated operating panel, etc.) When the key completes the current operation
order, it will automatically prompt the postback information on the completion of operation. If the key is closed
before postback, it can prompt such information again automatically when it restarts; the normal postback
interface is shown as follows:
If the operation orders are fully executed, it can put back to the adaptor for posted back, but you also can uses the
“function” menu’s feature. Select the “Suspend “option, it can directly postback data no matter the operation
orders finished or what.” It is available to execute the postback if the mimic panel (or the integrated operation
panel) is being in the postback state. It can return to the main menu automatically;
The suspension postback interface is shown as follows:
15
3.2.6 Browse orders
Browse Order Contents
The order browsing functions as browsing and checking the content of the current operating order in the smart key.
Select the Main Menu‐ “Browse” – > “Current” Contents to enter the option. If the smart key has not any
operating order, it will prompt “No operation order to review”, if the smart key has received the operating order,
press the Enter key to show the contents on the first item of the current operation order. Press the Down key to
show the contents of the next item, press the Up key to select the content of previous item, as shown below. Press
the Return key to the previous menu.
z Browse Recall
The option is to browse and check the content of the recalling data in the smart key. Select the Main Menu‐
“Browse” –> “ Previous” to enter the option. If the smart key did’t have any operating order, it will prompt “No
operation order to review”, if the smart key have the recalling data, press the Enter key to show the content on the
first page of the recall records. Press the Down key to select the contents of the next page, press the Up key to
select the content of previous page, and press the Enter key to browse the currently‐selected page, as shown
below.
It displays recalling order SNs from up to bottom; step number that has been operated under a SN, total step
number of operating orders; type of operating orders; ending status of operating order; receiving date and time of
operating order.
16
3.2.7 Function
Synchronization
See details in the section 3.2.2 Synchronization
z Check Code
The option is to check the code value or RFID value of the current lock. And it is also capable of showing the
corresponding device name. Select the Main Menu‐ “Function” –> “ChkCode” to enter the option, press the Enter
key to read the lock code or RFID code value. The code’s equipment name can be shown if exists. If the device
name doesn’t exist, it can show “This Dev isn’t exist”. Press the Return key to the previous menu. The interface is
shown as follows:
z Advance
In the main menu, select “Function” ‐ > “Advance” to enter the accessibility menu.
‹ Skip
Skip operation can be defined as to skip the option (that has been forcedly operated) currently displayed on the
smart key when the lock is abnormal and is unavailable to be unlocked by the smart key, and requires forced
unlocking by approval of the director in charge, thus continuing the next operation.
17
Insert the smart key step into the skipping key, the smart key begins to identify the skipping key and execute
skipping.
If skip operation is successful 5 seconds later, the smart key displays as follows:
If fails, the key displays:
Please remove the smart key from the skipping key when the skipping operation is successful, the smart key loads
the next operation automatically, and continues its operations.
‹ Clear Orders
If doesn’t want to operate an received operating order or post the result back, a user can press the Up or Down key
to select “Advance”‐> “ClearOdr”, and press Enter key, the key will show the following interface:
18
Thereinto:
z Press the Enter key to delete the order, the smart key will automatically return to the main menu; or press the
Return key to directly return to the main menu, rather than to delete the operation order.
Deploy
This menu provides a series of debugging programs special for professional test personal, and such test options are
unavailable to final users for further safe and reliable operations.
If a user enters the menu, the key will display an interface for inputting password, the user can ignore it, or press
The Return key to the previous menu, the operating interface is as shown as below:
Internal
This menu provides a series of debugging programs special for production personal, and such test options are
unavailable to final users for further safe and reliable operations.
If a user enters the menu, the key will display an interface for inputting password, the user can ignore it, or press
the Return key to the previous menu, the operating interface is as shown as below:
19
3.2.8 Settings
z NetWork
This menu provides a debugging tools special for professional deployment user, which is not available for normal
use. You have to enter the access password before enter the setting menu for further operation.
VoiceFunc
Select “Settings” ‐> “VoiceFunc” to enter this menu, and then set voice‐related options by operating various
sub‐menus.
‹ SetVoice
Select “VoiceFunc” ‐> “SetVoice” to enter Voice Settings interface, and press the “Close” button or the “Open”
button to disenable or enable voice setting state, or check voice setting status by small icons, as shown below:
‹ RecSet
Select “VoiceFunc” ‐> “RecSet” to enter Recording Settings interfaces, and press the “Close” button or the “Open”
button to disenable or enable recording function.
20
After the recording function is enabled, “record” or “ stop” button will appear on the user interface, as shown
below,
It is available to start up or stop recording as needed.
‹ Recpress
Select “VoiceFunc” ‐> “Recpress” to enter Audio compression interface, and press the “Close” button or the
“Open” button to disenable or enable the function. After the function is enabled, the system will compress and
save recorded audio, thus saving memory space.
‹
RecCopy
Select “VoiceFunc” ‐> “RecCopy” to enter Copy recording interface, and press the “Close” button or the “Open”
button to disenable or enable the function. After the function is enabled, connect smart keys to PC via USB cable, a
U disk icon will appear on PC, which is read‐only, enter the U disk to check REC folder, where the recording files are
saved by date and time. It is available to copy and import them into PC.
21
‹
RecTest
Select “VoiceFunc” ‐> “RecTest” to enter Recording test interface, and press the “Close” button or the “Open”
button to disenable or enable the function. the recording process is shown below:
Enter the menu, and wait for recording:
Press the “Record” button to start up recording:
Press the “Stop” button to stop recording, waiting for the next recording or press Back key to return:
22
‹
PlayTest
Select “VoiceFunc” ‐> “ PlayTest” to enter Playing test interface, and these audio files are stored in the REC folder
directory; a user can select an audio file by the “UP “ and “Down” buttons, and then play or delete such a file.
z Brightness
The menu functions as setting backlight brightness, Select “Settings” ‐> “ Brightness” on the main menu, to enter
the menu. Press the arrow keys to increase or decrease the backlight brightness; press the Enter key to save the
current backlight brightness level. Press the Cancel key to the previous menu.
z Time
The menu functions as setting time and date, Select “Settings” ‐> “ Time” on the main menu, to enter the menu,
as shown as below.
‹ Date Setting
Select “Time” ‐> “Date” to enter the option, and then move the cursor by operating the Down button, and adjust
the value by the Up button. Press the Enter key to confirm after setting is completed.
23
z Time Setting
Select “Time” ‐> “Time” to enter the option, and then move the cursor by operating the Down button, and
adjust the value by the Up button. Press the Enter key to confirm after setting is completed.
z Background
The menu functions as setting the background pattern of the user interface, Select“Settings” ‐> “ Background”to
enter the menu, as shown as below. Press the Up or Down key to select the background image, press the Enter key
to set, press the Return key to cancel the operation. The currently available backgrounds are two options as follows
(theme 2 is not available currently):
24
z Language
Select “Settings” ‐> “Language” to enter the option, and the optional languages include Chinese and English.
‹ Chinese
Select “Language” ‐ > “Chinese” to enter, and press the Enter key to select the Chinese.
‹ English
Select “Language” ‐ > “English” to enter, and press the Enter key to select the English.
25
3.2.9 About
Enter this option to check the software version, model number and manufacturer name.
Thereinto:
A user can press the return key directly to the main menu interface.
26
Chapter 4: Parameter settings
4.1 Auto Power‐off
The smart key will automatically power off if continues its standby state for 6 minutes, If it is being charged or
fully‐charged state, or being under cycle unlocking test for electric‐controlled lock or discharging test, the key will
cancel the auto power‐off, till the above state is canceled.
4.2 Auto sleep mode
If no button is pressed or the key is free of any operation orders or synchronization, the smart key will
automatically enter in sleep mode, and its screen will become black and indicator can flashes green periodically. If
any button is pressed or the key start receiving operation orders or synchronization, the key will exit the automatic
sleep mode, light up the screen, and display interface.
4.3 Interface Brightness
Under default conditions, the screen brightness is 6.
4.4 Display Language
The default interface language is English.
4.5. Interface themes
The default theme is theme 1. Only theme 1 is currently available.
4.6 Speaker status
The default speaker status is enabled
4.7. Recording function
The recording function is defaulted to disenabled
4.8 Audio compression
Under default conditions, the function is enabled.
27
Chapter 5 Display Descriptions
Under the standby mode, the green indicator flashes every 5 seconds,
The blue backlight lights up under key‐operating state,
From start‐up, running to normal operation, related prompts show the current state of the key, and part of
prompts s are shown in the following table:
Prompt
Description
Hardware fault,format is failed!
iNand mass storage device is damaged
Battery error!
The battery is improperly contracted or the
battery is damaged.
Same task number,cannot receive order
The same operating order has existed in the
system, and it fails to receive your new receiving
order
Memory is full,cannot receive order
Norflash is lack of storage space, unavailable to
receive operating order
Without sync, cannot receive order
The key should not receive operating order unless
completing synchronization
Creat or open file error!
file system is abnormal
Receive the data error!
RFID code is not sorted in descending order
Electrified! Locked out.
No electricity, please operate.
Error occurs during order receiving and
synchronization, the key will automatically delete
incorrect data.
RFID sequence isn’t correct in synchronous data
transmission from misoperation‐prevention host
to the key
The key detects the equipment is live and may
cause electric shock, prompts users not to operate
the device.
The key detects the equipment is safe, prompts
users to operate the device.
The above content is only part of prompt messages, which may vary under different operating state and different
modes. See details in the third chapter of this manual.
28
Chapter 6 Products Maintenance
6.1 Upgrade maintenance
If need to upgrade and maintain the product, please contact your local service personnel.
6.2 Routine maintenance
Please read the operating manual in details as well as Troubleshooting as shown in the next section to implement
routine maintenance.
6.3 Troubleshooting
Troubles
Causes
Solutions
The smart key cannot
synchronize , or is
abnormal in
synchronization.
1. Battery voltage is low.
2. synchronization
program is incorrectly
operated.
3. Transmission port of the
main control equipment is
damaged.
Mechanical coding lock is
opened, but unlocking
program cannot
continue.
1. Send the smart key back to Zhuhai
1. The internal IRDA
Unitech Power Technology Co., Ltd.
device of the smart key is
for repairing.
damaged.
2. Re‐adjust the horizontal position
2. Unlocking stem is offset.
or send it back to our company.
The smart key cannot
receive the operation
order sent from the
transmission port
1. The smart key has an
1. Clear the smart key, and then
operation order that is out
insert the transmission port to
of receiving state.
receive the operation order.
2. Internal IRDA device of
2. Send the smart key back to Zhuhai
the smart key is damaged.
Unitech Power Technology Co., Ltd.
3. IR transmission cover is
3. Sweep the dirt and clear the IR
blocked badly by dirt.
transmission cover.
4. The transmission port
4. Renew the transmission port of
of main control equipment
operation order.
is damaged.
29
1. Charge the smart key.
2. Operate the synchronization
program correctly.
3. Renew the transmission port of
the main control equipment.
1. The internal
components of the lock
are unsmooth.
The smart key shows
2. The ring is blocked by
“Code correctly, please external components.
unlock the mechanical
3. Battery voltage is low.
lock.” But the mechanical
4.
coding lock still cannot be Internal unlocking
components of the smart
opened.
key do not work.
5. The mechanical coding
lock is damaged.
When operating the
breaker, the breaker can
not be connected;
though the smart key
shows “Electric coding
lock can be opened.”
1. Internal relay of the
smart key is damaged.
2. The battery voltage is
low.
3. The smart key is in an
improper connection to
the electric coding lock.
The smart key says “The
The smart key did not
key has not synchronized,
synchronized before
not prepared for normal
operating normally.
operation.”
1. Renew the mechanical coding
lock.
2. When unlocking, press the
“Unlock” key, and then pull the lock
lightly manually.
3. Ensure charge adequate power
before operating the smart key.
4. Send the smart key back to Zhuhai
Unitech Power Technology Co., Ltd.
5. Renew the mechanical coding
lock.
1. Send the smart key back to Zhuhai
Unitech Power Technology Co., Ltd.
2. Ensure charge adequate power
before operating the smart key.
3. Clear the conductivity pole of the
electric coding lock, and renew the
electric coding lock if necessary.
Please synchronize.
1. The charger is damaged.
2. The battery has been
1. Repair or renew the charger.
used for such a long time 2. Renew the battery.
Fully charged in a charger,
that it causes the battery
but the battery runs out
3. Send the smart key back to Zhuhai
aging.
in a very short time.
Unitech Power Technology Co., Ltd.
3. The detection circuit for
power within the battery
is damaged.
30

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Modify Date                     : 2014:11:21 17:42:37+08:00
Create Date                     : 2014:11:18 10:19:40+08:00
Metadata Date                   : 2014:11:21 17:42:37+08:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:1cb7bbd9-6742-498a-9a65-c6b9ea121180
Instance ID                     : uuid:480b4101-591a-4972-90bf-071ea1c7ede8
Has XFA                         : No
Page Count                      : 37
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Z5FDNYS-2C

Navigation menu