Installation and Maintenance Instructions ® Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage Affix Model Number Label Here 86826 Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 1 of 12 Table of Contents Key Features ................................................. 3 Read These Warnings First ............................ 3 Check Your Package ...................................... 3 Installation Procedure .................................... 3 Set Up Water Discharge ................................ 4 Airbreak Installation ....................................... 4 Install Sensor ................................................. 5 Connect Latching Valve Cable........................ 6 Set Flush Timing............................................ 7 Maintenance Instructions ............................... 8 Completing Installation .................................. 8 Problem Solving............................................. 9 End of life disposal ........................................ 10 Notes pages .................................................. 11 Contact Details .............................................. 12 Accessories You will need one of these accessories (not included in the package). 99026 Zip FlushMaster Direct Injection Airbreak 1.50 inch BSP/ 38 mm 99025 Zip FlushMaster Direct Injection Airbreak 1.25 inch BSP/ 32 mm 99024 Zip FlushMaster Direct Injection Airbreak 1.00 inch BSP / 25 mm NOTE: Page 2 of 12 You may need the following (not included with this kit) 1) Isolation valve 2) 350 kPa Pressure reduction valve Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Key Features One of the world’s most effective, ceiling recessed, urinal flushing systems. This unit is supplied with a power pack for connection to 220-240 volt AC power. Smart Demand electronic programming allows for a variable flush cycle to meet your needs precisely. Narrow sensitivity beam protects against unwanted flushing operations. Read These Warnings First Read all instructions before attempting to install this system. Never attempt to install this system without reading all instructions. This unit is designed for indoor use only and should never be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned with a water jet. All plumbing connections must be made in accordance with AS/NZS3500 and installation with AS/NZS3500.2. Supply pressure 350kPa - 700kPa ( see recommendations on P7 ) Check Your Package Zip FlushMaster Solo package includes. Zip FlushMaster Solo WS005 Product Code 42214: Ceiling recessed Solo sensor complete with latching valve, power pack and plumbing Installation Procedure 1. 2. 3. 4. Set up water discharge with isolating valve, Latching Valve and Airbreak Install sensor Connect latching valve cable Set flush timing Isolation: An Isolation valve (not supplied) must be fitted, in an accessible position, upstream of this installation. Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 3 of 12 Set Up Water Discharge Typical Installation with Direct Injection: Model WS005 Sensor latching Valve Single stall Isolating Valve Direct injection air break Sensor latching Valve Single trough Maximum trough Width 600 mm Isolating Valve Direct injection air break Airbreak Installation. The air break must be fitted in a vertical position. Fitting in a position other than vertical will result in leakage. Fit the air break to the top of the urinal sparge pipe (in place of a cistern), as shown in the diagram. Locate as high as possible. Do not use sealing tape in the air break joints. The fittings in the latching valve will require the use of sealing tape. Supply and install a half-inch pipe from the top of the air break, to the outlet side of the latching valve. Securely fix the piping to the wall as per AS/NZS3500 to prevent possible tampering and vandalism. Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 4 of 12 Install Sensor Typical Installation with Ceiling Recessed Sensor (Model WS005) Example of minimum dimension Maximum dimension Example of maximum dimension * Ceiling sensor 424 * Ceiling sensor * * * NOTE: * dimensions may change depending on type and position of urina. * Position the centre of the ceiling sensor within *109 mm from the front of the urinal (as shown above). Typical sensor coverage from a 2400 mm ceiling will be less than 300 mm in front of the urinal. This is important to avoid false activation of the flushing program. To install the ceiling recessed sensor, cut a 64 mm diameter hole in the ceiling. Use the inbuilt clips to fasten the sensor housing in place when inserted into the hole. If any of the cable connecting the sensor to the latching valve is visible, shield it with conduit. Warning. Do not connect the power pack until all plumbing connections are completed. The power must be connected last as connection activates the system test mode (see pages 6 & 7). Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 5 of 12 Connect Latching Valve Cable 2 1 BLUE WIRE Page 6 of 12 Run the latching valve cable to the sensor in conduit or within the building wall and ceiling. Do not extend the cable as this will affect correct operation. Locate plug on cable from the latching valve and detach it from circuit board. The plug should be lifted directly upwards. Fasten the latching valve cable to the plug on the circuit board by first removing the plug from the board. Lift plug directly upwards and hold plug so fixing screws are facing you. Thread the cable through one of the holes in the the sensor lid, Secure the brown cable into the right hand screw terminal and tighten. Secure the blue cable into the left hand screw terminal and tighten. Push the plug into the socket on the circuit board, positioned so screws face towards the centre of the board. Finally, insert the cable from the power pack into the circuit board inlet socket . Once the power is connected, the system can be tested by operating in test mode.(see page 7) BROWN WIRE Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Set Flush Timing NOTE: Units supplied with a YELLOW rotary switch, will not have a test mode. For these units Position 0 will be non functional Test mode: The rotary switch on the board is marked 0 to 9 Position 0 is test mode, where the system will operate automatically for a number of cycles. Operational mode: Positions 1 to 9 are flush times in seconds (i.e. Valve opening times). When first powered the sensor will wait 2.5 minutes and then calibrate it’s surroundings, after this period it will be ready to detect. Setting Flush Time: The beam from the sensor is very narrow so care should be taken when installing so that it is mounted above the urinal where the user would be. The sensor will only accept someone as a user if they stand under the beam for 5 seconds or more, when the user walks away there is a 3 second delay and it will flush for the time you have set on the rotary switch. The unit can only be used with the supplied power pack. Mount the sensor away from lights, hot pipes, ceiling transformers and direct sunlight. Do not touch components on the board with your fingers. If the water pressure is greater than 700 kPa then a 350 kPa pressure reducing valve must be fitted upstream of the latching valve. Adjust the timing of the flush to ensure an adequate flush, by setting the flush switches on the sensor board (see diags. below) When setting the fill time ensure the water does not backup the connection pipe and spill out of the Air break. If the water is overflowing, or close to overflowing, reduce the fill time, or pressure. Alternatively, fit a 6 l/m flow restrictor. Recommended flush settings: The recommended setting for a single urinal is No.2, when supplied with 350 kPa water pressure. (see notes on page 11) Power connection (from power supply) Flush time selection (Seconds) Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 7 of 12 Maintenance Instructions Cleaning Keep the openings in the face of the sensor clear of dirt. Never clean the case with strong or abrasive cleaners. Wipe with a soft cloth, warm water and dish washing liquid. Never hose or spray any part of the flushing system. However to avoid the inconvenience associated with any malfunction of the flushing system, it is recommended that the latching valve diaphragm be replaced annually. The power must be turned off at the power point before any form of maintenance is attempted. Replacement rubber for diaphragm Valve Diaphragm Replacement Isolate power and water supply. Remove fixing clip on top of latching valve coil by levering up clip with screw driver and clicking back until clip releases from shaft. Lift coil, spring clip and spacer from latching valve shaft. Carefully undo the 4 screws retaining the valve housing. When the last screw is about to be released, grip the valve body and top section as it is spring loaded. Carefully separate the top section containing the spring and plungers from the lower body. The diaphragm should now be visible. Lift it out of position. Remove the centre plastic piece from the rubber diaphragm. Fit the new diaphragm to the plastic centre. Replace it in the same orientation. The centre plastic piece and the new diaphragm have two breather holes, try to align these together when reinstalling a new diaphragm. Re-assemble in the reverse of above. Note the position of all parts in the diaphragm for correct assembly. To order quote Zip part number 90279 Diaphragm Kit. Completing Installation After setting the desired filling time (p.7), Fit the sensor to the ceiling and wipe clean the outer surfaces.. Turn on the power and wait for 2.5 minutes. After this time the system will be ready to detect users Page 8 of 12 Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Problem Solving Symptoms System does not flush. Possible Causes Suggested Action Water supply turned off. Check water supply, turn on tap. Latching valve installed backwards. Reinstall latching valve correctly. Latching valve cable damaged or latching cable unplugged. Check cable and replug into sensor circuit board. Latching valve faulty. Replace latching valve. Sensor not activating. Check sensor as below. Not sensing user Must be visible for 5 sec, or more System flushes too long. Sensor duration time set incorrectly. Reset flush dial to a lower number See page 7 System flushes for a short period of time. Sensor duration time set incorrectly. Reset flush dial to a higher number See page 7 Sensor not active Wrong ceiling position Reposition sensor. See page 5 No Power Faulty GPO or household fuse Contact an electrician Faulty power supply Replace power pack System flushes continually except for time set as duration ‘on’ period. Sensor cable wires crossed. Uncross latching wire connection. Reversed valve polarity Change positions 1 &2 on socket (P6) System continually flushes. Valve diaphragm split Replace diaphragm. See page 8 latching valve faulty Replace latching valve False activation. Check for sensor vibration. Sensor not activating. Check sensor as below. Power turned off. Turn on power. Damaged sensor Replace Sensor Sensor lens blocked. Clean sensor lens Faulty sensor. Replace sensor. Flushing will not stop. Sensor not activating. Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 9 of 12 End of life disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details WELS Ratings: This system, when tested with a Caroma Leda urinal achieves a 4 Star WELS rating. In order to maintain the WELS ratings for alternative urinals, the flushMaster must be set to deliver the correct volume of water as specified by the urinal manufacturer. Page 10 of 12 Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 NOTES Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 11 of 12 Contact Details Head Office Zip Heaters (Aust) Pty. Ltd. ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia Website: www.zipheaters.com Facsimile: (02) 9796 3858 Telephone: (02) 9796 3100 Free Call: 1 800 638 633 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01 Page 12 of 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : vivianl Create Date : 2012:05:17 15:10:55+10:00 Modify Date : 2012:05:17 15:10:55+10:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : 86826 - WR_FlushMaster Solo Mk2_AU_04-12v1.01.indd Creator : vivianl Producer : Acrobat Distiller 9.5.1 (Windows) Document ID : uuid:20f5220e-8c89-4359-ac1a-26364f19865a Instance ID : uuid:d6bc0485-cce4-49ab-899f-9171bc17f6aa Page Count : 12EXIF Metadata provided by EXIF.tools