Installation and Maintenance Instructions
®

Zip FlushMaster Solo
Water Saver Urinal Flushing System
Keeps Urinals Clean & Reduces Water Wastage

Affix Model Number Label Here
86826

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 1 of 12

Table of Contents

Key Features ................................................. 3
Read These Warnings First ............................ 3
Check Your Package ...................................... 3
Installation Procedure .................................... 3
Set Up Water Discharge ................................ 4
Airbreak Installation ....................................... 4
Install Sensor ................................................. 5
Connect Latching Valve Cable........................ 6
Set Flush Timing............................................ 7
Maintenance Instructions ............................... 8
Completing Installation .................................. 8
Problem Solving............................................. 9
End of life disposal ........................................ 10
Notes pages .................................................. 11
Contact Details .............................................. 12

Accessories
You will need one of these accessories (not included in the package).

99026 Zip FlushMaster Direct Injection Airbreak 1.50 inch BSP/ 38 mm
99025 Zip FlushMaster Direct Injection Airbreak 1.25 inch BSP/ 32 mm
99024 Zip FlushMaster Direct Injection Airbreak 1.00 inch BSP / 25 mm

NOTE:

Page 2 of 12

You may need the following (not included with this kit)
1) Isolation valve
2) 350 kPa Pressure reduction valve

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Key Features
One of the world’s most effective, ceiling recessed, urinal flushing systems.
This unit is supplied with a power pack for connection to 220-240 volt AC power.
Smart Demand electronic programming allows for a variable flush cycle to meet
your needs precisely.
Narrow sensitivity beam protects against unwanted flushing operations.

Read These Warnings First
Read all instructions before attempting to install this system.
Never attempt to install this system without reading all instructions.
This unit is designed for indoor use only and should never be installed outdoors or
exposed to the elements of nature. This unit must not be positioned in an area that
may be cleaned by a water jet. This unit must not be cleaned with a water jet.
All plumbing connections must be made in accordance with AS/NZS3500 and
installation with AS/NZS3500.2.
Supply pressure 350kPa - 700kPa ( see recommendations on P7 )

Check Your Package
Zip FlushMaster
Solo package
includes.

Zip FlushMaster Solo WS005 Product Code
42214:
Ceiling recessed Solo sensor complete with
latching valve, power pack and plumbing

Installation Procedure
1.
2.
3.
4.

Set up water discharge with isolating valve, Latching Valve and Airbreak
Install sensor
Connect latching valve cable
Set flush timing

Isolation:
An Isolation valve (not supplied) must be fitted, in an accessible position, upstream
of this installation.
Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 3 of 12

Set Up Water Discharge
Typical Installation with Direct Injection: Model WS005
Sensor

latching Valve

Single stall

Isolating Valve
Direct injection
air break

Sensor
latching Valve

Single trough
Maximum trough
Width 600 mm
Isolating Valve
Direct injection
air break

Airbreak Installation.


The air break must be fitted in a vertical position. Fitting in a position other
than vertical will result in leakage.



Fit the air break to the top of the urinal sparge pipe (in place of a cistern),
as shown in the diagram. Locate as high as possible.



Do not use sealing tape in the air break joints. The fittings in the latching
valve will require the use of sealing tape.



Supply and install a half-inch pipe from the top of the air break, to the
outlet side of the latching valve.



Securely fix the piping to the wall as per AS/NZS3500 to prevent possible
tampering and vandalism.

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 4 of 12

Install Sensor
Typical Installation with Ceiling Recessed Sensor (Model WS005)

Example of
minimum
dimension

Maximum
dimension
Example of
maximum
dimension

*

Ceiling sensor

424
*

Ceiling sensor

*

*

*

NOTE: * dimensions may change depending
on type and position of urina.

*

Position the centre of the ceiling sensor within *109 mm from the front of the
urinal (as shown above).
Typical sensor coverage from a 2400 mm ceiling will be less than 300 mm
in front of the urinal. This is important to avoid false activation of the flushing
program.
To install the ceiling recessed sensor, cut a 64 mm diameter hole in the
ceiling.
Use the inbuilt clips to fasten the sensor housing in place when inserted into
the hole.
If any of the cable connecting the sensor to the latching valve is visible, shield
it with conduit.
Warning. Do not connect the power pack until all plumbing connections are
completed. The power must be connected last as connection activates the
system test mode (see pages 6 & 7).

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 5 of 12

Connect Latching Valve Cable

2

1

BLUE
WIRE

Page 6 of 12

Run the latching valve cable to the sensor in conduit or within the building wall
and ceiling.
Do not extend the cable as this will affect correct operation.
Locate plug on cable from the latching valve and detach it from circuit board.
The plug should be lifted directly upwards.
Fasten the latching valve cable to the plug on the circuit board by first
removing the plug from the board. Lift plug directly upwards and hold plug so
fixing screws are facing you.
Thread the cable through one of the holes in the the sensor lid,
Secure the brown cable into the right hand screw terminal and tighten.
Secure the blue cable into the left hand screw terminal and tighten.
Push the plug into the socket on the circuit board, positioned so screws face
towards the centre of the board.
Finally, insert the cable from the power pack into the circuit board inlet socket
.
Once the power is connected, the system can be tested by operating in test
mode.(see page 7)

BROWN
WIRE

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Set Flush Timing
NOTE:
Units supplied with
a YELLOW rotary
switch, will not have
a test mode.
For these units
Position 0 will be
non functional

Test mode:
The rotary switch on the board is marked 0 to 9
Position 0 is test mode, where the system will operate automatically for a number of cycles.
Operational mode:
Positions 1 to 9 are flush times in seconds (i.e. Valve opening times).
When first powered the sensor will wait 2.5 minutes and then calibrate it’s surroundings,
after this period it will be ready to detect.
Setting Flush Time:
The beam from the sensor is very narrow so care should be taken when installing so that it
is mounted above the urinal where the user would be.
The sensor will only accept someone as a user if they stand under the beam for 5 seconds
or more, when the user walks away there is a 3 second delay and it will flush for the time
you have set on the rotary switch.
The unit can only be used with the supplied power pack.
Mount the sensor away from lights, hot pipes, ceiling transformers and direct sunlight.
Do not touch components on the board with your fingers.
If the water pressure is greater than 700 kPa then a 350 kPa pressure reducing valve must
be fitted upstream of the latching valve.
Adjust the timing of the flush to ensure an adequate flush, by setting the flush switches on
the sensor board (see diags. below)
When setting the fill time ensure the water does not backup the connection pipe and spill
out of the Air break. If the water is overflowing, or close to overflowing, reduce the fill time,
or pressure. Alternatively, fit a 6 l/m flow restrictor.
Recommended flush settings:
The recommended setting for a single urinal is No.2, when supplied with 350 kPa water
pressure. (see notes on page 11)

Power connection (from power supply)
Flush time selection (Seconds)
Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 7 of 12

Maintenance Instructions

Cleaning
Keep the openings in the face of the sensor clear of dirt.
Never clean the case with strong or abrasive cleaners.
Wipe with a soft cloth, warm water and dish washing liquid.
Never hose or spray any part of the flushing system.
However to avoid the inconvenience associated with any malfunction of the
flushing system, it is recommended that the latching valve diaphragm be
replaced annually.
The power must be turned off at the power point before any form of
maintenance is attempted.

Replacement
rubber for
diaphragm

Valve Diaphragm Replacement
Isolate power and water supply.
Remove fixing clip on top of latching valve coil by levering up clip with screw
driver and clicking back until clip releases from shaft.
Lift coil, spring clip and spacer from latching valve shaft.
Carefully undo the 4 screws retaining the valve housing. When the last screw
is about to be released, grip the valve body and top section as it is spring
loaded.
Carefully separate the top section containing the spring and plungers from the
lower body. The diaphragm should now be visible. Lift it out of position.
Remove the centre plastic piece from the rubber diaphragm. Fit the new
diaphragm to the plastic centre. Replace it in the same orientation. The centre
plastic piece and the new diaphragm have two breather holes, try to align
these together when reinstalling a new diaphragm.
Re-assemble in the reverse of above. Note the position of all parts in the
diaphragm for correct assembly. To order quote Zip part number 90279
Diaphragm Kit.

Completing Installation

After setting the desired filling time (p.7), Fit the sensor to the ceiling and wipe
clean the outer surfaces.. Turn on the power and wait for 2.5 minutes. After
this time the system will be ready to detect users

Page 8 of 12

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Problem Solving

Symptoms
System does not flush.

Possible Causes

Suggested Action

Water supply turned off.

Check water supply, turn on tap.

Latching valve installed backwards.

Reinstall latching valve correctly.

Latching valve cable damaged or
latching cable unplugged.

Check cable and replug into sensor
circuit board.

Latching valve faulty.

Replace latching valve.

Sensor not activating.

Check sensor as below.

Not sensing user

Must be visible for 5 sec, or more

System flushes too long.

Sensor duration time set incorrectly.

Reset flush dial to a lower number
See page 7

System flushes for a short period of
time.

Sensor duration time set incorrectly.

Reset flush dial to a higher number
See page 7

Sensor not active

Wrong ceiling position

Reposition sensor.
See page 5

No Power

Faulty GPO or household fuse

Contact an electrician

Faulty power supply

Replace power pack

System flushes continually except for
time set as duration ‘on’ period.

Sensor cable wires crossed.

Uncross latching wire connection.

Reversed valve polarity

Change positions 1 &2 on socket (P6)

System continually flushes.

Valve diaphragm split

Replace diaphragm. See page 8

latching valve faulty

Replace latching valve

False activation.

Check for sensor vibration.

Sensor not activating.

Check sensor as below.

Power turned off.

Turn on power.

Damaged sensor

Replace Sensor

Sensor lens blocked.

Clean sensor lens

Faulty sensor.

Replace sensor.

Flushing will not stop.

Sensor not activating.

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 9 of 12

End of life disposal
In order to help preserve our environment we ask that you dispose of this
product correctly. Please contact your local city council for collection centre
details

WELS Ratings:
This system, when tested with a Caroma Leda urinal achieves a 4 Star WELS
rating. In order to maintain the WELS ratings for alternative urinals, the
flushMaster must be set to deliver the correct volume of water as specified by
the urinal manufacturer.

Page 10 of 12

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

NOTES

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 11 of 12

Contact Details

Head Office
Zip Heaters (Aust) Pty. Ltd.
ABN 46 000 578 727
67 Allingham Street
Condell Park NSW 2200
Postal: Locked Bag 80
Bankstown 1885 Australia
Website: www.zipheaters.com
Facsimile: (02) 9796 3858
Telephone: (02) 9796 3100
Free Call: 1 800 638 633

As Zip policy is one of continuous product improvement, changes to specifications may
be made without prior notice. Images in this booklet have been modified and may not be
true representations of the finished goods

Zip FlushMaster Solo Installation & Maintenance Instructions - 86826 - April 2012 v1.01

Page 12 of 12



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : vivianl
Create Date                     : 2012:05:17 15:10:55+10:00
Modify Date                     : 2012:05:17 15:10:55+10:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : 86826 - WR_FlushMaster Solo Mk2_AU_04-12v1.01.indd
Creator                         : vivianl
Producer                        : Acrobat Distiller 9.5.1 (Windows)
Document ID                     : uuid:20f5220e-8c89-4359-ac1a-26364f19865a
Instance ID                     : uuid:d6bc0485-cce4-49ab-899f-9171bc17f6aa
Page Count                      : 12
EXIF Metadata provided by EXIF.tools

Navigation menu