Zip G4 Vent Tray Kit June 2015 v1.00
ZIP Vent Tray Kit Installation
1.
Before installing the Vent Tray Kit.
Ensure the 4mm silicon door buffers are fitted
to the inside of the cupboard doors to allow
sufficient air to enter the cupboard space.
If there is insufficient air flow through the
cupboard, an air inlet grill (not supplied) will
need to be fitted to the upper part of the door or
to an exterior wall of the same cupboard space.
2.
For marking purposes, place the assembled vent
tray kit in a suitable position on the cupboard
floor. Check there will be sufficient clearance
around, the final placement of, the undersink
unit and that the undersink unit will be close to
the Hydrotap hose and tube connections, as
specified in the main installation instructions.
3.
With the vent tray assembly in position, secure
the outlet duct section to the front of the
cupboard floor, using the two small screws
supplied.
4.
Adjust the depth of the main box section by
sliding the box back to suit the size of your
undersink unit. Check both sides of the box are
square with the outlet duct section.
5.
Mark the final position of the main box on the
cupboard floor and then remove the outlet
duct section to reveal all four of the main box
mounting locations.
6.
With the main box in place (check against the
marks made in step 5) mark and drill out the 4
main box mounting locations.
7.
With the vent tray assembly removed from the
cupboard, cut an outlet vent into the front edge
of the cupboard floor so that it is located evenly
between the two screw holes made in step 3.
The cut out should be between 300-450mm wide
and cut back close to the kickboard (nominal
43mm).
8.
Replace the main box and secure in place with
the 4 large screws supplied.
9.
Refit the outlet duct section to the front of the
main box and secure in place with the 2 small
screws supplied (as in step 3).
NOTE: The Vent Tray Kits 93540 (for BC and BCS models) and 93541 (for C and CS models) are both
installed in the same way.
93540 assembled
vent tray kit
Main Box
Outlet Duct
300-450mm
cut out
Finished assembly
2
3
4
7
9
Head Office
Zip Heaters (Aust) Pty. Ltd.
ABN: 46 000 578 727
67 Allingham Street
Condell Park NSW 2200
Postal: Locked Bag 80
Bankstown 1885 Australia
Website:
www.zipindustries.com
Facsimile: (02) 9796 3858
Telephone: (02) 9796 3100
Sales & Service.
Free Call: 1 800 63 86 33
Customer Care.
Free Call: 1 800 42 43 44

Navigation menu