etatronix EXM10RXLINK Wireless Power Receiver User Manual exm10 series datasheet Draft 01
etatronix GmbH Wireless Power Receiver exm10 series datasheet Draft 01
Contents
- 1. Users Manual
- 2. Integration manual
Users Manual
etatronix exm10 series 10W Wireless Power Receiver with Battery Charger exm10 series 10W Wireless Power Receiver with Battery Charger Introduction The exm module series provides easy to use plug and play solutions for high performance wireless power transmission between a power transmitter (Tx) and a power receiver (Rx). In combination with a proprietary data transmission channel, the series provides a fast regulation loop and the ability to transfer customer data in parallel. Compliance to global safety and EMC standards qualifies the series for worldwide markets. The exm10 series contains easy to use power receiver modules that can be wirelessly powered with any etatronix exm10 power receiver. They provide up to 10 W at the DC output. A LiIon charge function as well as a battery management system including a state of charge algorithm is available. In combination with an exm10 power transmitter, the system complies to CE and FCC regulations. It has a modular approval which minimizes the certification effort of the application containing the module. Features • Up to 85% Efficiency • 10 W Continuous Output Power • Fast Dynamic Response • Foreign Object Detection • Up to 2kbps Data Transmission • Low Standby Consumption • Battery Management Functionality • Low Emissions, Compliance to – EN 55011/CISPR 11 class B – FCC, part 15 & 18 – IEC / EN 61000-4-3,4,5,6,8 – Works with any exm10 Wireless Power Transmitter exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 1 / 10 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger Table of Contents 1 Electrical Specification 1.1 Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Mechanical Specification 2.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Interfaces 3.1 Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Battery Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 Signal Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Functional Description 5 Compliance 5.1 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . References 10 Revision History Revision Date Changes Draft-01 11/2017 First Draft Release 2 / 10 exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger 1 Electrical Specification 1.1 Operating Conditions Min Typ Max Unit Output voltage1 20 Output current1,2 2.7 Parameter -25 70 Standby current 3 tbd. mA Data transmission frequency MHz Ambient temperature ◦ In case of a connected battery, output current and voltage depend on actual charge state. The module works in CC/CV mode. Output current limitation can be tailored to specific load and battery requirements. Receiver module not connected with power transmitter, BMS active. 1.2 Interface Parameter Min Typ Max Unit Low level digital interface 1 -0.1 0.6 High level digital interface 1 2.7 3.4 Maximum voltage at PG 1,2 4.2 Maximum current PG 1 10 mA Output Capacity 440 µF Battery Fuse Rating T7 Battery Fuse Melting Integral 8.7 A2 Sec Internal limiting series resistor: 330 Ω. Voltage at PG-pin shall not exceed the output voltage. 1.3 Compliance Regulation Description EN 55011 class B EMI regulation for home equipment exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 3 / 10 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger 2 Mechanical Specification 2.1 Dimensions Figure 1: Dimensions Length Width Height Weight 60.0mm +/-0.2 46.0mm +/-0.2 10.6mm +/-0.21 tbd Notice that the height varies and will be higher at the solder points. 4 / 10 exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger 2.2 Mounting Figure 2 shows two possible examples for the mounting of the exm module. Using the provided holes, the module can be mounted on a separate carrier (a) or on the surface which faces the power coil (b). In order to fit onto the module, the screw-head should have a maximum diameter of 5.5mm. The height of the standoffs should be at least 6mm. (a) Carrier Mounting (b) Surface Mounting Figure 2: Mounting Examples exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 5 / 10 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger 3 Interfaces The interface of the exm module consists of a power output to connect the load, a signal output for communication with the module or via the wireless link and a separate battery connector. Figure 3: Interfaces 3.1 Power Connector Type: TE Connectivity 1-292173-3 Pin Name Function Vout- Output GND PG Power Good1 Vout+ Output Voltage Open collector to GND 3.2 Battery Connector Type: TE Connectivity 1-292173-3 6 / 10 exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 exm10 series 10W Wireless Power Receiver with Battery Charger Pin Name Function GND Battery - NTC Thermistor of the battery to GND1 Vbat+ etatronix Battery +2 Open collector to GND Protected by an internal Fuse 3.3 Signal Connector Connection to the signal connector is not necessary for power transmission but can be used for status updated and customer-specific data transmission. More details are specified in [1]. Type: JST SM04B-SRSS-TB Pin Name Function VCCint Internal Supply Voltage COM1 I2 C SDA, UART Tx1 COM2 I2 C SCL, UART Rx1 GNDint Internal GND Depending on configuration exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 7 / 10 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger 4 Functional Description Figure 4: Block Diagram To maximize the power transmission efficiency, the power transmission between transmitter and receiver modules of the exm10 series is realized using resonant circuits. These resonant circuits additionally provide the ability to vary the transmitted power by changing the switching frequency. By increasing the switching frequency, the available power in the receiver side decreases. For the accurate output voltage regula- 8 / 10 tion, a control loop is necessary. The output conditions like output current, voltage and power are measured on the receiver side and sent to the power transmitter. If corrections are necessary, the transmitter will change the switching frequency to the desired value. An appropriate control loop needs a fast signal transmission with little delay. Often it’s advantageous to transfer status or customer-specific information between both units. To meet these two demands, the exm10 series provides a data channel that allows the parallel transmission of analog regulation information as well as digital status and customer-specific information. This transmission is done using a second pair of coupled coils. Like the power transmission coils, the signal coils are forming a near field coupling system thus the intended use of radio waves isn’t necessary. exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 exm10 series 10W Wireless Power Receiver with Battery Charger etatronix 5 Compliance 5.1 Compliance Regulation Description EN 55011/CISPR11 class B Industrial, scientific and medical equipment - Radiofrequency disturbance characteristics - Limits and methods of measurement IEC/EN 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radiofrequency, electromagnetic field immunity test IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4:Testing and measurement techniques - Electrical fast transient/burst immunity test IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017 9 / 10 etatronix exm10 series 10W Wireless Power Receiver with Battery Charger References [1] etatronix GmbH, FDD - Kommunikation über UART mit WirelessPower Modul Beschreibung der UART Kommunikation mit einem etatronix Lademodul, Jun. 14, 2017. 10 / 10 exm10 series-datasheet-Draft-01.pdf © etatronix GmbH, November 2017
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 10 Page Mode : UseOutlines Author : etatronix GmbH Title : exm10 series-datasheet-Draft-01 Subject : Creator : MiKTeX, TeXnic Center with KOMA-Script and hyperref Producer : pdfTeX-1.40.17 Create Date : 2018:05:09 08:24:55+02:00 Modify Date : 2018:05:09 08:24:55+02:00 Trapped : False PTEX Fullbanner : This is MiKTeX-pdfTeX 2.9.6211 (1.40.17)EXIF Metadata provided by EXIF.tools