iHealth Labs HS4S Wireless Scale Lite User Manual HS4S OM

iHealth Lab Inc. Wireless Scale Lite HS4S OM

User Manual

iHealth Wireless Scale Lite User Manual TABLE OF CONTENTS WELCOME BOX CONTENTS MOBILE DEVICE COMPATIBILITY COMPANION MOBILE APP ACCESS IHEALTH CLOUD USING THE IHEALTH WIRELESS SCALE LITE SCALE HANDLING & USAGE SOFTWARE UPDATES PRODUCT SPECIFICATIONS SAFETY INFORMATION TROUBLESHOOTING CARE & MAINTENANCE WARRANTY INFORMATION EXPLANATION OF SYMBOLS ON UNIT
WELCOME Congratulations  on  your  new  iHealth  Wireless  Scale  Lite  with  Bluetooth® Smart  Ready technology. This Scale tracks your weight and BMI and, along with the free companion “iHealth MyVitals” app, can help you stay motivated and reach your weight goals.  BOX CONTENTS Your iHealth Wireless Scale Lite package contains: • 1 iHealth Wireless Scale Lite • 4 AAA batteries, not installed • 1 Quick Start Guide • 1 User Manual  MOBILE DEVICE COMPATIBILITY The iHealth Wireless Scale Lite works with the following devices: Apple devices using iOS system version 6.0 and higher:   • iPhone 4S or later • iPad mini or later • iPad (3rd generation) or later • iPod touch (5th generation) or later                                                                                                      Android devices using system version 4.0 and higher :   • Samsung® GALAXY S2, S3, S4, S5 • Samsung® NOTE II , III • Samsung® Mega 6.3 • LG® NEXUS 4,5 • HTC One® M7, M8 • HTC Droid DNA  Compatible devices are subject to change. For the latest compatibility list, go to www.ihealthlabs.com/support/  COMPANION MOBILE APP Scan the QR code to download the free “iHealth MyVitals” companion app or directly from the Apple App Store or the Google play. Follow the on-screen instructions to register and set up your iHealth ID.  ACCESS IHEALTH CLOUD Upon setting up your iHealth ID, you will also have access to a free, secure iHealth cloud account.
Go to www.ihealthlabs.com, then click on “Sign In” to access your cloud account from a PC or Mac using your iHealth ID. USING THE IHEALTH WIRELESS SCALE LITE 1. Install the batteries   Open the battery compartment on the bottom of the Scale and install the batteries. 2. First-time Use For your first weigh-in, follow these steps to ensure the Scale and the app are connected and that the date and time synchronize correctly. If you have an iOS device:  1. Enable the Bluetooth on your mobile device (Settings->Bluetooth->On).  2. Tap the Scale to turn it on.    3. Launch the app to initiate the connection. The Bluetooth icon on your device will light up and stop flashing when a successful connection is established. You will also see the Bluetooth icon on your Scale lights up. The Scale is now connected and ready for your weigh-in.  If you have an Android device: Go to Settings, and turn on the Bluetooth .You may need to press “Scan” or “Search” to find the Scale.   “iHealth HS4Sxxxx” and “Not Paired ” should appear on the device list momentarily. Select the scale name “iHealth HS4Sxxxx” to pair and connect. If the connection is successful, you will see "Connected" appear on the device screen.  3. Your Next Weigh-in Subsequent daily weigh-ins can be taken without being connected to your mobile device, as your weight data is stored in the Scale and uploaded to the app upon your next connection. Real-time weight results are viewable in the app if the Scale is connected to your mobile device and the app is running when your weigh-in occurs. The Scale can store up to 200 weight measurements. When the memory is full, any new measurements will overwrite the oldest ones.
SCALE HANDLING & USAGE • The iHealth Wireless Scale Lite can measure weights up to 400 lb. • For best results, the Scale should be used on a flat, hard surface. Soft surfaces, such as carpeting or rugs, may affect the accuracy of your reading. • The iHealth Wireless Scale Lite has an automatic shut-down feature to conserve battery power. The following scenarios will cause the Scale to go into automatic shutdown mode: º One minute has passed after completion of successful weigh-in. º The battery level is too low to capture an accurate weight reading. SOFTWARE UPDATES From time to time, the Scale's firmware will be updated to enhance performance. When a software update is available, a notification message will appear in the app. Complete the following steps to install the update: 1) Follow steps in the "First-time Use" section. 2) You will see a notification message in the app asking for permission to proceed. Select "Yes". 3) The update will begin to download. You will see a cursor on the scale display moving from left to right. The scale will display "0.0" when the update is complete. Software Update Troubleshooting If the software update fails for any reason, you might experience one of the following: 1. An error message reading “Er 10” appears in the display area. In this case, the Scale software will automatically revert to factory settings. The Scale will count up to 100 and then back to 0.0. This step requires no user action. When the Scale has finished counting down to 0.0, repeat Steps 1-2 above to restart the software update. 2.  The  count up  from 1  to  100  freezes  and  stops progressing. Restart the  Scale  by pressing  the “Set” key on the back of the Scale next to the battery compartment and hold it for 8 seconds.  PRODUCT SPECIFICATIONS 1. Product name: iHealth Wireless Scale Lite 2. Model: HS4S 3. Classification: Internally powered 4. Machine dimensions: 13.8"x13.8"x1.1" (350 mm×350 mm×28.5 mm) 5. Weight: Approximately 5.5 lb (2500 g) 6. Measuring method: Automatic full electronic measurement 7. Power: 4×1.5V    AAA batteries     Battery life: Approximately 3 months with twice daily usage 8. Measurement range:
    Body Weight: 11 lb - 400 lb / 5 kg - 180 kg 9. Accuracy:       Body Weight: ±0.5kg/1.1Lb (5kg~50kg/11Lb~110Lb);                             ±1% (50kg~180kg/110Lb~400Lb); 10. Operating temperature: 5   ℃- 40   (41°F~104°F)℃ 11. Operating humidity:    20 - 85%RH 12. Environmental pressure for operation: 86~106kPa 13. Storage and transport temperature: -20   ℃- 55  (℃-4°F~131°F) 14. Storage and transport humidity: ≤90%RH 15. Environmental pressure for storage: 50~106kPa 16. Scale resolution:0.2lb/0.1kg  Note: These specifications are subject to change without notice. SAFETY INFORMATION Read all of the information in the User Manual and any other documents in the box before using the unit. 1. Please stand on the Scale, keep as still as possible until the result appears on the display. 2.  Do  not  stand  on  the  edge of  Scale, as  you  may fall  over  or  influence  the accuracy of  the measurement. 3.  Do not use the Scale on a tiled or wet floor, as this may result in a fall. 4.  Make sure the surface of the Scale is clean and dry before you step onto it, to prevent any slippage. 5.  Treat your Scale with care. Do not drop it or jump on it. The Scale is designed to be stood on; misuse  or  abuse  may  break  the  electronic  sensors,  cause  injury,  or  result  in  inaccurate measurements. 6.  Never immerse the Scale in water. Clean the surface with a damp cloth. 7. Do not use the Scale on an uneven floor or soft surfaces such as carpets or rugs while weighing, as doing so may result in unreliable measurements. 8. To avoid damage as a result of battery leakage, remove the batteries if the Scale is not going to be used for 3 months or more. 9. Do not use or store near strong magnetic fields, such as microwave ovens. 10. The Scale may not perform accurately if it is stored or used outside the specified temperature and humidity ranges specified in the “Specifications”. 11. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause undesired operation. Cet appareil est conforme à la section 15  des réglementations de la FCC. Le fonctionnement de l’appareil est sujetaux deux conditions suivantes : (1) cet appareil ne doit pas provoquer d’interférences néfastes, et (2) cet appareil doit tolérer les interférences reçues, y compris celles qui risquent de provoquer un fonctionnement indésirable. 12.  Changes  or  modifications  not  expressly  approved  by  iHealth  Lab  Inc.  invalidate  the  user’s
warranty for this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the instructions,  may  cause  harmful  interference  to  radio  communications.  However,  there  is  no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect  the  equipment  to  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is connected. —Consult the dealer or an experienced radio/TV technician for help. Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 13.  This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1)This device may not cause interference, and 2)This  device  must  accept  any  interference,  including  interference  that  may  cause  undesired operation of the device. Le  présent  appareil  est  conforme  aux  CNR  d'Industrie  Canada  applicables  aux  appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)  l'utilisateur  de  l'appareil  doit  accepter  tout  brouillage  radioélectrique  subi,  même  si  le brouillage est susceptible d'en compromettre le fonctionnement. 14.  Under  Industry  Canada  regulations,  this  radio  transmitter  may  only  operate  using  an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce  potential radio interference to other users, the antenna type and its gain should  be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. TROUBLESHOOTING Issue Possible Cause Troubleshooting Steps Bluetooth icon on the Scale display won’t stop flashing. Bluetooth connection failed. Make sure Bluetooth is enabled, the Scale is turned on and the app is running. If  the  problem  persists,  restart the mobile device and try again. Scale display shows “Lo.” Battery level is low. Change the batteries. Scale displays shows “Er 0.” The Scale failed to initialize. Remove the batteries, wait for one minute, then reinstall them.
Scale display shows “Er 1.” Maximum weight has been exceeded. The maximum weight allowed is 400 lb/180 kg. Scale displays “Er 2.” The Scale can’t capture a steady reading. 1. Allow the Scale to shut off completely before trying again. 2. Place feet on the center of glass platform and stand still. Scale displays “Er 4.” Bluetooth connection error. Reset the Bluetooth connection  by  turning  it  off and  on  in  your  mobile  device setting. Scale displays “Er 9.” Scale memory access error. Remove the batteries, wait one minute, then reinstall. Scale displays “Er10.” Software update error. Refer to the “Software Update” sectionfor instructions. CARE & MAINTENANCE 1. Avoid high temperatures and irradiation. 2. If the Scale is stored close to freezing point, allow it to acclimate to room temperature before use. 3. Do not attempt to disassemble the Scale. 4. Remove the batteries if the Scale is not going to be used for 3 months or more. 5.  Clean  the  Scale  with  a  soft  damp  cloth.  Do  not  use  abrasive  or  solvent-based  cleaners,  and never immerse it in water. 6. The device will maintain its safety and performance features for at least 3,000 measurements. WARRANTY INFORMATION iHealth Lab, Inc. ("IHealth") warrants the iHealth hardware (the "Product"), and only the Product, against defects in materials and workmanship under normal use for a period of one year (365 days) from  the  date  of  purchase  by  the  original  purchaser  ("Warranty  Period").  Under  this  Limited Warranty, if  a defect  arises  and a  valid claim  is received by iHealth within the  Warranty  Period regarding the Product, at its option and to the extent permitted by law, iHealth will either (1) repair the Product using new or refurbished replacement parts or (2) exchange the Product with a new or refurbished Product. In the event of a defect, to the extent permitted by law, these are the sole and exclusive remedies. You can read our full return and warranty policy on our website by visiting www.ihealthlabs.com/ Manufactured for iHealth Lab, Inc. 719 N. Shoreline Blvd, Mountain View, CA 94043 USA +1-855-816-7705 www.ihealthlabs.com Made in China EXPLANATION OF SYMBOLS ON UNIT Refer to the User Manual Warning
Please recycle where facilities exist. Waste electrical products should not be disposed of with household waste. Check with your local authority or retailer for recycling advice. Manufacturer Keep dry Complies with RTTE 99/5/EC Requirements ANDON HEALTH CO., LTD. No. 3 Jinping Street, YaAn Road, Nankai District, Tianjin 300190, China. Tel: 86-22-60526161 Bluetooth® associated logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by iHealth Lab Inc.is permitted under license. Other trademarks and trade names are those of their respective owners.