Cyclone LC Programmers
User Manual

Purchase Agreement
P&E Microcomputer Systems, Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. P&E Microcomputer Systems, Inc. does not assume any liability arising out of the application or use of any product or circuit described herein. This software and accompanying documentation are protected by United States Copyright law and also by International Treaty provisions. Any use of this software in violation of copyright law or the terms of this agreement will be prosecuted. All the software described in this document is copyrighted by P&E Microcomputer Systems, Inc. Copyright notices have been included in the software. P&E Microcomputer Systems authorizes you to make archival copies of the software and documentation for the sole purpose of back-up and protecting your investment from loss. Under no circumstances may you copy this software or documentation for the purpose of distribution to others. Under no conditions may you remove the copyright notices from this software or documentation. This software may be used by one person on as many computers as that person uses, provided that the software is never used on two computers at the same time. P&E expects that group programming projects making use of this software will purchase a copy of the software and documentation for each user in the group. Contact P&E for volume discounts and site licensing agreements. P&E Microcomputer Systems does not assume any liability for the use of this software beyond the original purchase price of the software. In no event will P&E Microcomputer Systems be liable for additional damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use or inability to use these programs, even if P&E Microcomputer Systems has been advised of the possibility of such damage. By using this software, you accept the terms of this agreement.
©2015-2020 P&E Microcomputer Systems, Inc. ARM and Cortex are registered trademarksof ARM Ltd. or its subsidiaries. NXP, ColdFire, and Kinetis are registered trademarks of NXP Semiconductors. Texas Instruments and TI are registered trademarks of Texas Instruments Incorporated. STMicroelectronics is a registered trademark of STMicroelectronics, Inc. macOS is a registered trademark of Apple, Inc. All other product or service names are the property of their respective owners.
P&E Microcomputer Systems, Inc. 98 Galen St. Watertown, MA 02472 617-923-0053 http://www.pemicro.com
Manual version: 1.23 November 2020

1 INTRODUCTION......................................................................................................................................... 9
1.1 Supported Devices ..........................................................................................................................................9 1.2 Distinguishing Windows-Only And macOS/Linux-Specific Content ..............................................................10
1.2.1 Minimum Required Versions ....................................................................................................................................... 10 1.3 Additional Resources ....................................................................................................................................10
2 QUICK START GUIDE FOR SAP OPERATION....................................................................................... 11
2.1 Installing The Cyclone Software....................................................................................................................11 2.2 Setting Up The Cyclone Hardware................................................................................................................11 2.3 Creating A Stand-Alone Programming Image ..............................................................................................13
2.3.1 Advanced Features ..................................................................................................................................................... 17 2.4 Launching Cyclone Programming .................................................................................................................17
3 CYCLONE LC HARDWARE ..................................................................................................................... 19
3.1 Touchscreen LCD .........................................................................................................................................19 3.2 LED Indicators...............................................................................................................................................19 3.3 Start Button ...................................................................................................................................................19 3.4 Access Panel.................................................................................................................................................19 3.5 Cyclone System Power .................................................................................................................................20 3.6 RS232 Communication (Serial Port) .............................................................................................................20 3.7 Ethernet Communication...............................................................................................................................20 3.8 USB Communications ...................................................................................................................................20 3.9 Electromechanical Relays .............................................................................................................................20 3.10 Power Connectors.........................................................................................................................................21 3.11 Reset Button..................................................................................................................................................21 3.12 SDHC Port.....................................................................................................................................................21 3.13 Optional Oscillator (MON08 Only).................................................................................................................22 3.14 Cyclone Time / Real Time Clock ...................................................................................................................22 3.15 Power Jumper Settings .................................................................................................................................22 3.16 Debug Connectors ........................................................................................................................................22 3.17 Target Headers For Part# CYCLONE-LC-ARM ............................................................................................24
3.17.1 PORT A: 10-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices) ................... 24 3.17.2 PORT B: 20-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices) ................... 25 3.17.3 PORT C: 20-Pin Debug Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices) .......................... 26 3.18 Target Headers For Part# CYCLONE-LC-UNIV ...........................................................................................27 3.18.1 PORT A: 10-Pin Keyed Mini Connector (NXP Kinetis & S32 (ARM), other PEmicro-Supported ARM devices, Infineon
TriCore) ....................................................................................................................................................................... 27 3.18.2 PORT B: 20-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices) ................... 29 3.18.3 PORT C: 14-Pin Debug Connector (MPC55xx-57xx, SPC5, DSC, S32 (Power)) ...................................................... 30 3.18.4 PORT D: 26-Pin Debug Connector (ColdFire V2/3/4)................................................................................................. 31 3.18.5 PORT E: 16-Pin Debug Connector (MON08).............................................................................................................. 32 3.18.6 PORT F: 6-Pin Debug Connector (RS08, HCS08, HC(S)12(X), S12Z, ColdFire +/V1, STM8 w/ adapter)................. 32 3.18.7 PORT G: 10-Pin Debug Connector (Power MPC5xx/8xx) .......................................................................................... 33

3.18.8 PORT H: 20-Pin Debug Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices, Infineon TriCore) . 33 3.19 Ribbon Cable.................................................................................................................................................35

4 TARGET POWER MANAGEMENT .......................................................................................................... 37

4.1 Cyclone Configuration ...................................................................................................................................37

4.2 Cyclone Setup ...............................................................................................................................................39

4.2.1 Independently Powered Target ................................................................................................................................... 39

4.2.2 4.2.3 4.2.4 4.2.5 4.3

Power provided by the Cyclone to the debug cable .................................................................................................... 39 External Power passed through the Cyclone and out 2.5 mm barrel port................................................................... 40 External Power passed through the Cyclone to the debug cable................................................................................ 40 Power provided by the Cyclone and out 2.5 mm barrel port ....................................................................................... 41 Setup Reminders...........................................................................................................................................41

5 TOUCHSCREEN LCD MENU................................................................................................................... 42

5.1 Home Screen ................................................................................................................................................42

5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.2

Icons............................................................................................................................................................................ 42 Configurable Display Area........................................................................................................................................... 42 Status Window ............................................................................................................................................................ 43 Error Information Icon.................................................................................................................................................. 43 AUX Button (Appears If Configured) ........................................................................................................................... 43 Main Menu.....................................................................................................................................................43

5.2.1 5.2.2 5.2.3 5.2.4

Select Programming Image......................................................................................................................................... 45 Current Image Options ................................................................................................................................................ 45 Configure Cyclone Settings......................................................................................................................................... 47 Status .......................................................................................................................................................................... 50

6 CREATING AND MANAGING PROGRAMMING IMAGES....................................................................... 51

6.1 Cyclone Image Creation Utility .....................................................................................................................51

6.1.1 6.1.2

Specify CPU Manufacturer.......................................................................................................................................... 52 Security Settings - Qorivva (MPC55xx-57xx) Only...................................................................................................... 54

6.1.3 6.1.4 6.1.5 6.1.6 6.1.7 6.1.8 6.1.9 6.1.10 6.1.11

Secure Boot Settings - NXP i,MX RT Only.................................................................................................................. 54 Secure JTAG Settings - NXP i,MX RT Only................................................................................................................ 55 Programming Sequence.............................................................................................................................................. 56 Programming Operations ............................................................................................................................................ 58 Communication Mode and Rate Settings.................................................................................................................... 64 Target Voltage and Power Settings............................................................................................................................. 64 Image Description ....................................................................................................................................................... 64 ProCryption Security Features .................................................................................................................................... 64 FX Exclusive Features ................................................................................................................................................ 67

6.1.12 Store Image To Cyclone.............................................................................................................................................. 67

6.1.13 Store Image To Disk.................................................................................................................................................... 68 6.1.14 Save Cyclone Configuration........................................................................................................................................ 68 6.1.15 Load Cyclone Configuration ........................................................................................................................................ 68 6.2 Managing Multiple SAP Images ....................................................................................................................68

6.2.1 Delete Images From Internal/External Memory........................................................................................................... 69

6.2.2 Add/Remove Images From The Commit Changes Panels ......................................................................................... 69

7 CYCLONE PROGRAMMER MANUAL CONTROL................................................................................... 71

7.1 Operation Via Start Button ............................................................................................................................71

7.1.1 7.1.2 7.1.3 7.2

LED Indicators............................................................................................................................................................. 71 Procedure via Start Button / LEDs .............................................................................................................................. 71 Example ...................................................................................................................................................................... 71 Operation Via LCD Touchscreen Menu ........................................................................................................72

7.3 Home Screen ................................................................................................................................................72

7.3.1 Icons............................................................................................................................................................................ 72 7.3.2 Configurable Display Area........................................................................................................................................... 72 7.4 Status Window ..............................................................................................................................................73

7.4.1 7.4.2

Error Information Icon.................................................................................................................................................. 73 AUX Button (Appears If Configured) ........................................................................................................................... 73

7.4.3 Main Menu................................................................................................................................................................... 73

8 CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE) ........................ 76

8.1 Cyclone Control Suite - Overview .................................................................................................................76

8.1.1 8.1.2 8.1.3 8.1.4 8.1.5

macOS/Linux Support Notes....................................................................................................................................... 76 Components ................................................................................................................................................................ 77 Standard Features....................................................................................................................................................... 77 Advanced Features ..................................................................................................................................................... 77 PEmicro Compatible Hardware ................................................................................................................................... 78

8.2 Cyclone Control SDK ....................................................................................................................................78

8.2.1 8.2.2 8.2.3 8.2.4 8.2.5 8.2.6

Introduction ................................................................................................................................................................. 78 Backwards Compatibility With Classic Cyclone Control API ...................................................................................... 78 Getting Started with the Cyclone Control Library File - Windows Users .................................................................... 78 Getting Started with the Cyclone Control Library File - macOS/Linux Users ............................................................ 80 Initialization.................................................................................................................................................................. 81 Finalization .................................................................................................................................................................. 82

8.2.7 Initial Cyclone Setup.................................................................................................................................................... 82 8.2.8 Typical Usage.............................................................................................................................................................. 82 8.2.9 External Memory Storage Support .............................................................................................................................. 83 8.2.10 Application Programming Interface (API) .................................................................................................................... 83 8.3 Cyclone Control Console...............................................................................................................................96

8.3.1 8.3.2

Startup......................................................................................................................................................................... 96 Command-Line Parameters ........................................................................................................................................ 96

8.3.3 Examples..................................................................................................................................................................... 99 8.4 Cyclone Control GUI ...................................................................................................................................100

8.4.1 8.4.2 8.4.3 8.5

The Connection Dialog.............................................................................................................................................. 101 The Control Tabs....................................................................................................................................................... 101 The Status and Error Window: .................................................................................................................................. 107 License ........................................................................................................................................................107

8.5.1 Hardware Licensing................................................................................................................................................... 107

9 SAP IMAGE COMPILER (SCRIPTED PROGRAMMING & IMAGE CREATION) .................................. 108
9.1 Launching From the Command Line ...........................................................................................................108 9.1.1 Command-Line Example........................................................................................................................................... 108 9.1.2 Filename and Additional Command-Line Parameters............................................................................................... 109 9.1.3 List of Valid Command-Line Parameters................................................................................................................... 109
9.2 Configuration (.CFG) File Contents.............................................................................................................110 9.2.1 Sample .CFG File...................................................................................................................................................... 110 9.2.2 Configuration Commands.......................................................................................................................................... 111 9.2.3 Programming Commands ......................................................................................................................................... 117 9.2.4 Using Command Line Parameters Inside a .CFG File .............................................................................................. 118 9.2.5 Sample Batch File ..................................................................................................................................................... 119
9.3 CSAP Error Returns ....................................................................................................................................119
10 ETHERNET CONFIGURATION.............................................................................................................. 121
10.1 Network Architectures .................................................................................................................................121 10.2 Network Parameters....................................................................................................................................121 10.3 Internet Protocol ..........................................................................................................................................122 10.4 Connecting The Cyclone Device .................................................................................................................122
10.4.1 Connecting the Cyclone to the PC over a network.................................................................................................... 122 10.4.2 Connecting Cyclone-to-PC via an Ethernet cable ..................................................................................................... 123 10.5 Cyclone IP Setup Via LCD Menu ................................................................................................................123 10.5.1 Configure Network Settings....................................................................................................................................... 123 10.6 Configuring Cyclone Network Settings using the Cyclone Control GUI ......................................................124
11 SAP IMAGE ENCRYPTION .................................................................................................................... 126
11.1 Overview .....................................................................................................................................................126 11.2 Encrypting/Decrypting a Programming Image.............................................................................................126 11.3 What is Encrypted in an eSAP File, and How .............................................................................................126 11.4 Managing Encryption For Production Programming ...................................................................................127
11.4.1 Provisioning a Cyclone with an ImageKey ................................................................................................................ 127 11.4.2 Removing ImageKeys From A Cyclone .................................................................................................................... 129 11.4.3 Loading and Programming with Encrypted SAP Images .......................................................................................... 129 11.4.4 Encryption Status of SAP Images ............................................................................................................................. 130 11.5 Safer Production That's Easy To Implement ...............................................................................................131
12 AUTOMATIC SERIAL NUMBER MECHANISM .................................................................................... 132
12.1 Understanding Serialization ........................................................................................................................132 12.2 Serialize Utility.............................................................................................................................................132
12.2.1 Startup And File Options ........................................................................................................................................... 133 12.2.2 Serial Number File..................................................................................................................................................... 134 12.2.3 Serial File Unique ID ................................................................................................................................................. 134 12.2.4 Serial File Name To Display...................................................................................................................................... 134 12.2.5 Serial File Notes ........................................................................................................................................................ 134 12.2.6 Number of Bytes in Serial Number............................................................................................................................ 134

12.2.7 Starting HEX Address ............................................................................................................................................... 134 12.2.8 Count Sequence ....................................................................................................................................................... 134 12.2.9 Serial Number Bytes as Hex ..................................................................................................................................... 134 12.2.10 Hex Upper Bounds .................................................................................................................................................... 135 12.2.11 Hex Lower Bounds .................................................................................................................................................... 135 12.2.12 Binary, Numeric, Constant, Alpha Upper, Alpha Lower, and Printable ..................................................................... 135 12.2.13 Byte Program Order .................................................................................................................................................. 135 12.3 Serial File Properties ...................................................................................................................................135 12.3.1 Serial File Example ................................................................................................................................................... 135 12.4 Serial Number Handling ..............................................................................................................................136 12.4.1 Invoking A Serial File Via Command-Line................................................................................................................. 137 12.5 Creating A SAP Image With Multiple Serial Numbers.................................................................................137 12.6 Shared Serial Numbers ...............................................................................................................................138 12.6.1 Example .................................................................................................................................................................... 138
13 CYCLONE LICENSE INSTALLATION .................................................................................................... 143
13.1 How to Install Your License.........................................................................................................................143
14 TROUBLESHOOTING ............................................................................................................................ 148
14.1 My Cyclone Is Non-Responsive, Is There A Way To Re-Activate It?..........................................................148 14.1.1 What Is Bootloader Mode?........................................................................................................................................ 148 14.1.2 When Is Bootloader Mode Used? ............................................................................................................................. 148 14.1.3 How Is Bootloader Mode Entered? ........................................................................................................................... 148
14.2 I Received A "SAP Image Needs To Be Updated" Error Using A Next-Gen Cyclone, How Do I Update? .148 14.2.1 How Do I Use SAP_Convert_Console.exe? ............................................................................................................. 148
14.3 When Trying To Install The CYCLONE Software, A Popup WDREG Error Occurs Telling Me That There Are Open Devices Using WinDriver...................................................................................................................149
15 ERROR CODES...................................................................................................................................... 150
15.1 Debug Mode Communication Related Errors..............................................................................................150 15.2 SAP Image Handling Related Errors...........................................................................................................150 15.3 SAP Communication Handling Related Errors............................................................................................151 15.4 SAP Algorithm Header Operation Handling Related Errors ........................................................................151 15.5 SAP Operation Related Errors ....................................................................................................................151 15.6 SAP Blank Check Range and Module Related Errors ................................................................................151 15.7 SAP Erase Range and Module Related Errors ...........................................................................................151 15.8 SAP Program Byte, Word, and Module Related Errors...............................................................................151 15.9 SAP Verify Checksum Related Errors.........................................................................................................152 15.10 SAP Verify Range and Module Related Errors ...........................................................................................152 15.11 SAP User Function Related Errors..............................................................................................................152 15.12 SAP Trim Related Errors.............................................................................................................................152 15.13 Unrecoverable Fatal Errors .........................................................................................................................152 15.14 Operation Security Related Errors ..............................................................................................................153 15.15 External Memory-Related Errors.................................................................................................................153

15.16 Serial Number Related Errors .....................................................................................................................154 15.17 Download Count Related Errors..................................................................................................................154 15.18 System Hardware/Firmware/Logic Recoverable Errors ..............................................................................154
16 OPTIONAL FEATURE ACTIVATIONS ................................................................................................... 155
16.1 ProCryption Security ...................................................................................................................................155 16.2 Cyclone Control Suite Advanced Features .................................................................................................155 16.3 SDHC Port Activation ..................................................................................................................................155
17 TECHNICAL INFORMATION.................................................................................................................. 156
17.1 Life Expectancy ...........................................................................................................................................156 17.2 Electrical Specifications...............................................................................................................................156 17.3 Mechanical Specifications ...........................................................................................................................156 17.4 Electromechanical Relays ...........................................................................................................................156 17.5 Debug Ports - CYCLONE-LC-ARM.............................................................................................................156 17.6 Debug Ports - CYCLONE-LC-UNIV ............................................................................................................156 17.7 International Shipping..................................................................................................................................156 17.8 Compliances/Standards ..............................................................................................................................156

1 INTRODUCTION
PEmicro's Cyclone LC production programmers are powerful, fast, and feature rich in-circuit programming solutions. PEmicro offers two models which have the same feature set and only vary by the devices supported.
Part# CYCLONE-LC-ARM supports a wide variety of ARM Cortex devices.
Part# CYCLONE-LC-UNIV supports those ARM Cortex devices as well as the following NXP device families: Kinetis, LPC, S32, MPC55xx-57xx), MPC5xx/8xx, DSC, S12Z, RS08, S08, HC08, HC(S)12(X), ColdFire. It also supports Infineon's TriCoreTM (AUDOTM TC1xx and AURIXTM TC2xx/ TC3xx) and STMicroelectronics' SPC5 & STM8 (with STM8 adapter).
Note: PEmicro refreshed Cyclone names and part numbers in July 2019. The part numbers listed on earlier Cyclones will differ slightly. CYCLONE is now called Cyclone LC, however the hardware has not changed.

1.1

Supported Devices

PART#: CYCLONE-LC-UNIV

PART#: CYCLONE-LC-ARM
ARM Cortex Devices:
Atmel: SAMxxx Cypress: CCG2, CCG3PA, EZ-BLE-
PSoC-PRoC, EZ-BLE-PSoC6, FM3 PRoC-BLE, PSoC4, PSoC5, PSoC6, Traveo II Infineon: XMC Maxim Integrated: DARWIN NordicSemi: nRF51, nRF52 NXP: Automotive, iMX, Kinetis, LPC, Sensors, Vybrid OnBright: OB90Rxx Redpine Signals: WiSeMCU Silergy (Maxim): AM0x, AM1x, MAX716xx Silicon Labs: EFM32, EFR32, SiM3 STMicroelectronics: STM32 Texas Instruments: LM3S, LM4, SimpleLink, TM4C12x Toshiba: TX00, TX03, TX04 WIZnet: W7500x

8/16/32 bit devices:
NXP: S32 ColdFire® V1 ColdFire® V2/V3/V4 Qorivva® (MPC5xxx) DSC ARM Nexus (MAC7xxx) S12Z HC(S)12(X) HC08, HCS08, RS08
Infineon: TriCore (AUDO TC1xx & AURIX TC2xx/ TC3xx)
STMicro: SPC5 STM8 (with STM8 adapter)

Figure 1-1: Cyclone LC Device Support by Part Number
Cyclone LC programmers are designed to withstand the demands of a production environment. They are Stand-Alone Programmers (SAP) that can be operated manually or used to host automated programming. In manual SAP mode the Cyclone is operated using the touchscreen LCD Menu and/or the Start button. Host-controlled SAP mode, for automated programming, is accomplished using the Cyclone Control Suite.

User Manual For Cyclone LC Programmers

9

1.2

Distinguishing Windows-Only And macOS/Linux-Specific Content

Many control and automation features offered by the Cyclone Control Suite are available for macOS and Linux platforms, in addition to Windows. See CHAPTER 8 - CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE). However, some elements such as Image Creation remain Windows-only.

The matrix below indicates at a high level which Cyclone features are available for each platform:

Cyclone Control GUI
Cyclone Control Console
Cyclone Control SDK
Image Creation Utility
SAP Image Compiler
Initiate Programming with Barcode Scanner
Automatic Serial Number Mechanism

Windows x x x x x
x
x

macOS x x x

Linux x x x

1.2.1
1.3

Table A-1. Cyclone Feature Support
In this user manual, information that pertains to the Windows platform only, or is particular to macOS/Linux, is indicated by the symbols below. Content can be considered to apply to all three platforms unless otherwise specified.
Windows-only: macOS: Linux:
Minimum Required Versions The following are the minimum versions required for macOS/Linux support. macOS: 10.13 High Sierra Linux: 18.04 LTS
Additional Resources
Several sections of this user manual will point the user to related articles that appear on the PEmicro.com blog. These articles often contain a more detailed exploration of the topic at hand. They can be browsed in aggregate under the Product Blog tab of the Cyclone LC product page:
pemicro.com/CycloneLC-blog The Cyclone LC product page also contains a Learning Center tab where important concepts related to the Cyclone are organized into Experts Corners (in-depth exploration of a topic) and User Guides (how to accomplish a specific task):
pemicro.com/CycloneLC-learning

User Manual For Cyclone LC Programmers

10

2 QUICK START GUIDE FOR SAP OPERATION
This guide will allow the user to set up and program a simple Stand-Alone Programming (SAP) image with the Cyclone by completing the following steps.
· Installing the Cyclone software
· Setting up the Cyclone hardware
· Creating a stand-alone programming image
· Launching Cyclone programming
This guide is intended as a supplement to the Cyclone's User Manual, which contains in-depth information about the topics covered here and much more.

2.1

Installing The Cyclone Software

First, the Cyclone software should be installed on the user's PC. It can be downloaded from the Support & Downloads tab on the pemicro.com Cyclone product page, or directly from https:// www.pemicro.com/downloads/download_file.cfm?download_id=481.

For macOS/Linux, download the .TGZ file from the Support & Downloads tab, or directly from https:// www.pemicro.com/downloads/download_file.cfm?download_id=577.
Once the software is downloaded, the user should install it on their PC. If Cyclone software is already installed on the PC, it is recommended that the old installation be removed before the user installs the latest software.

2.2

Setting Up The Cyclone Hardware

Step 1. Configure Cyclone power settings

The Cyclone has several different power configurations. The label on the bottom of the Cyclone indicates the appropriate Jumper settings for each. The user should install the Jumpers as indicated for their desired power configuration.

The Jumpers are located underneath the Cyclone's access panel. They are labeled "Power Jumpers." and numbered from 1-4. The Cyclone-LC-ARM is shown in the example below; the jumper location will be similar for all Cyclone models.

User Manual For Cyclone LC Programmers

11

If power is provided via the Cyclone, the user may need to configure the programming image accordingly. Image creation and configuration is discussed in Section 2.3 - Creating A Stand-Alone Programming Image. For more information on the various power configurations, the user should refer to their Cyclone's User Manual. There is a also a blog post that covers this topic at: http://www.pemicro.com/blog/ index.cfm?post_id=121 Step 2. Connect Cyclone to a PC (for programming image setup) The Cyclone programmer should be connected to the PC via USB, Serial, or Ethernet. Cables for each of these options are included with the Cyclone. Note: An Ethernet connection requires IP setup on the Cyclone unit; please refer to the Cyclone's User
Manual for more information.
Step 3. Connect Cyclone to target A ribbon cable should be connected from the appropriate Cyclone header (located under the Cyclone's access panel) to the header for your target device. Ribbon cables are provided with the Cyclone.

User Manual For Cyclone LC Programmers

12

Step 4. Plug in power to the Cyclone
The provided power supply should be plugged into the System Power jack of the Cyclone programmer. Other power connections should be made according to the power configuration selected in Step 1.

On power-up the user may need to agree to a firmware update on the Cyclone unit.

2.3

Creating A Stand-Alone Programming Image

A stand-alone programming (SAP) image is the result of pre-processing the programming algorithms, data to be programmed, programming options, and scripted programming commands. These are combined into a single encrypted file. This SAP image can then be loaded onto the Cyclone and used to program, without need for the Cyclone to be connected to a PC.

The Cyclone Image Creation Utility, shown below, allows the user to configure and save SAP images. A simple programming image can be created in 6 steps:

Step 1. Run Cyclone Image Creation Utility

Step 2. Select Device Manufacturer & Device

Step 3. Set Up Programming Sequence

Step 4. Add Basic Programming Commands

Step 5. Configure Additional Settings

Step 6. Save SAP Image To Cyclone

User Manual For Cyclone LC Programmers

13

The following instructions walk the user through each of these steps: Step 1. Run Cyclone Image Creation Utility
CreateImage.exe is in the "ImageCreation" folder, in the location where the Cyclone software was installed. For an in-depth description of the Cyclone Image Creation Utility, see Section 6.1 - Cyclone Image Creation Utility.
Step 2. Select Device Manufacturer and Device Specify CPU Manufacturer and Select New Device are used to choose the manufacturer of the target device, and then the specific device or architecture.

User Manual For Cyclone LC Programmers

14

Step 3. Programming Sequence Setup
The user should double-click on CM in the Programming Sequence window to choose the appropriate Algorithm for the target device. They can navigate to the algorithm using the dialog provided.

Based on the algorithm that was selected, additional commands will be made available in the box of programming commands on the left.
The user should then double-click on the SS command to specify the Object Code.

User Manual For Cyclone LC Programmers

15

Step 4. Adding Basic Programming Commands
The user should then add other basic programming commands, using the list of commands on the left side of the Programming Sequence area. The arrow and buttons allow the user to add, remove, and re-sequence the commands, in the box on the right. As an example, some basic commands might be
· Erase
· Program
· Verify

Note: Launch Script Wizard can also be used to quickly complete Steps 3 and 4.
Step 5. Other Settings The user should then specify any other settings that the SAP image should contain in order to program correctly, such as · Communication SWD vs JTAG · Shift frequency · Target Power and Voltage Settings

User Manual For Cyclone LC Programmers

16

These settings can be made using the corresponding areas of the Cyclone Image Creation Utility.

Step 6. Save SAP image to Cyclone
The user should then save the SAP image onto the Cyclone by clicking the button to save to "Cyclone Only" or "Cyclone & Disk." The image will be automatically selected as the current SAP image on the Cyclone.

2.3.1
2.4

Advanced Features
Cyclone programmers can take advantage of several advanced features that are beyond the scope of this Getting Started guide, such as RSA/AES encrypted programming images, programming restrictions on images (see Section 6.1.10 - ProCryption Security Features), and use of a barcode scanner to launch programming (see CHAPTER 12 - USING A BARCODE SCANNER TO SELECT AN IMAGE & INITIATE PROGRAMMING). CYCLONE FX programmers include all of these features, and CYCLONE programmers can use many of these features with the appropriate activation license.
Launching Cyclone Programming
There are three ways to launch programming. 1. Cyclone Start Button Press - The user simply presses the Start button located on top of the Cyclone programmer.

2. Cyclone Control Console (command-line utility) - The user writes a script that specifies parameters and initiates programming using the command line. More information is available in the Cyclone's User manual or at: http://www.pemicro.com/blog/

User Manual For Cyclone LC Programmers

17

index.cfm?post_id=142

3. SDK - The SDK is a software library that is used in conjunction with the user's own code. The user writes a customer application that uses this library of functions to launch programming. More information is available in the Cyclone's User Manual, or at: http:// www.pemicro.com/blog/index.cfm?post_id=139

The "Success" or "Error" LED will illuminate to let the user know the result of programming.

Note:

If programming is unsuccessful when using this quick start procedure, the user may instead wish to use the included PROG software for their target device. The PROG software allows the user to manually walk through the programming procedure step by step, which may help determine which part of setup or programming function is causing difficulty.

User Manual For Cyclone LC Programmers

18

3 CYCLONE LC HARDWARE
The following is an overview of the features and interfaces of Cyclone LC programmers. Many of these interfaces are labeled on the underside of the plastic case.

Figure 3-1: Cyclone LC Top View

3.1

Touchscreen LCD

The LCD Touchscreen displays information about the Cyclone's configuration and the programming process, and also allows the user to navigate the Cyclone's menus. The location of the Touchscreen LCD is shown in Figure 3-1.

3.2

LED Indicators

The LED indicators for Error or Success will illuminate depending on the results of the programming process and provide a clear visual indication of the results. The location of the LED Indicators is shown in Figure 3-1.

3.3

Start Button

The Start Button can be used to begin the programming process manually, provided that the Cyclone is properly configured. The location of the Start Button is shown in Figure 3-1.

3.4

Access Panel

The Access Panel can easily be opened to allow the user to connect/disconnect ribbon cables from the headers, or to configure the Cyclone's Power Jumpers to select one of the available Power Management setups. The location of the Access Panel is shown in Figure 3-1; a layout of the headers and jumpers beneath the Access Panel is shown in Figure 3-5.

User Manual For Cyclone LC Programmers

19

Figure 3-2: Cyclone LC Right Side View

3.5

Cyclone System Power

The Cyclone LC programmer requires a regulated 6V DC Center Positive power supply with 2.5/ 5.5mm female plug. Cyclones derive power from the Power Jack located on the right end of the unit. The location of Cyclone System Power is shown in Figure 3-2.

3.6

RS232 Communication (Serial Port)

The Cyclone LC provides a DB9 Female connector to communicate with a host computer through the RS232 communication (115200 Baud, 8 Data bits, No parity, 1 Stop bit). The location of the Serial Port is shown in Figure 3-2.

3.7

Ethernet Communication

The Cyclone LC provides a standard RJ45 socket to communicate with a host computer through the Ethernet Port (10/100 BaseT). The location of the Ethernet Port is shown in Figure 3-2.

3.8

USB Communications

The Cyclone LC provides a USB connector for Universal Serial Bus communications between the Cyclone and the host computer. The Cyclone LC is a USB 2.0 Full-Speed compliant device. The location of the USB Port is shown in Figure 3-2.

3.9

Electromechanical Relays

Inside the Cyclone LC programmer, two electromechanical relays are used to cycle target power. The specifications of the relays are as following:

Maximum switched power: Maximum switched current: Maximum switched voltage:
UL Rating:

30W or 125 VA 1A 150VDC or 300VAC 1A at 30 VDC 1A at 125 VAC

PEmicro only recommends switching DC voltages up to 24 Volts.

User Manual For Cyclone LC Programmers

20

3.10 3.11

Figure 3-3: Cyclone LC Front Side View
Power Connectors
The Cyclone LC programmers provide a Target Power Supply Input Jack and a Target Power Supply Output Jack with 2.5/5.5 mm Pin Diameter. The power jacks are connected or disconnected by two electromechanical relays. When connected, the Center Pin of the Target Power Supply Input Jack is connected to the Center Pin of the Target Power Supply Output Jack. When disconnected, both terminals of the Target Power Supply Output Jack are connected to GND via a 1W, 100 Ohm resistor. The location of Target Power In is shown in Figure 3-3, and the location of Target Power Out is shown in Figure 3-3.
Reset Button
The Reset Button performs a hard reset of the Cyclone system. The location of the Reset Button is shown in Figure 3-3.

Figure 3-4: Cyclone LC Rear Side View

3.12

SDHC Port
Note: The SDHC port is activated on all Cyclone FX programmers, and may be activated on Cyclone LC programmers via purchase of the SDHC Port Activation License.
The SDHC port allows the user to store programming images that are, individually or collectively, larger than the Cyclone's internal memory. It also makes it quicker and more convenient to swap programming images. PEmicro offers certified SDHC cards on our website at pemicro.com. The location of the SDHC Port is shown in Figure 3-4.
Programming images are managed on the SD card in exactly the same way as they are in the Cyclone's internal memory. Please see Section 6.2 - Managing Multiple SAP Images for more information about using the Manage Images utility.
To view detailed information about the status of the SDHC card/port, tap the icon bar at the top of the touchscreen menu. This status can provide you with relevant information if you are

User Manual For Cyclone LC Programmers

21

3.13 3.14 3.15 3.16

encountering any difficulty while trying to use an SDHC card. SDHC cards with a memory capacity up to 4GB are supported. Cards with a larger capacity may work but have not been tested by PEmicro.
Optional Oscillator (MON08 Only)
Cyclone LC programmers with MON08 support (PEmicro Part# CYCLONE-LC-UNIV only) provide a software configurable 9.8304MHz or 4.9152 MHz oscillator clock signal to Pin 13 of the MON08 Connector. The user may use this clock signal to overdrive the target RC or crystal circuitry. If this signal is not used, just leave Pin 13 of the target MON08 header unconnected. Please note that if the target already uses an oscillator as its clock, the Cyclone will NOT be able to overdrive it. The clock should have sufficient drive to be used with a target system even if the target system has an RC circuit or crystal connected.
Cyclone Time / Real Time Clock
Cyclone LC programmers are equipped with a Real Time Clock (RTC) module designed to keep accurate timing even when the Cyclone is turned off. The Date & Time are displayed on the home screen. Date/Time settings can be configured by navigating to the following menu using the touchscreen display:
Main Menu / Configure Cyclone Settings / Configure Time Settings For more information on the available configuration options, see Section 5.2.3.3 - Configure Time Settings (Cyclone Time / Real Time Clock).
Power Jumper Settings
The Power Jumpers must be set differently for various power management options that the Cyclone LC offers. If the target is being powered independently of the Cyclone LC, all pins in the Power Jumpers header must instead be left unpopulated. To reveal the Power Jumpers header, lift the access panel on the left end of the Cyclone LC. The location is indicated as Power Jumpers in Figure 3-5. Please see CHAPTER 4 - TARGET POWER MANAGEMENT for the correct jumper settings for the Cyclone's power management options. A quick guide to these settings is also located on the underside label of the Cyclone LC.
Debug Connectors
When purchasing a Cyclone LC programmer, the user is able to choose between two part numbers, each corresponding to a different level of device support. See the sticker on the underside of the Cyclone to determine the PEmicro part# for your specific Cyclone LC programmer. PEmicro Part# CYCLONE-LC-ARM supports ARM Cortex devices only, so this programmer provides one shrouded, un-keyed, 0.100-inch pitch dual row 0.025-inch square header, and two shrouded, keyed 0.050-inch pitch dual row mini headers. PEmicro Part# CYCLONE-LC-UNIV supports ARM Cortex devices and additionally supports target connections to many 8-/16-/32-bit NXP architectures, so this programmer provides six shrouded, un-keyed, 0.100-inch pitch dual row 0.025-inch square headers, and two shrouded, keyed 0.050-inch pitch dual row mini headers. To reveal the headers and connect/disconnect ribbon cables, lift the access panel on the left end of the Cyclone. Each header is designated for one or more specific target architectures, as indicated in Figure 3-5.

User Manual For Cyclone LC Programmers

22

Figure 3-5: Target Headers & Power Jumpers (CYCLONE-LC-UNIV vs.CYCLONE-LC-ARM)
Mechanical drawings are shown below whose dimensions are representative of the pin size and spacing of these headers. Note: The number of pins depicted in the mechanical drawings may differ from the Cyclone headers; the drawings are provided simply to demonstrate pin size and spacing.

Figure 3-6: 20-Pin Un-Keyed Header Dimensions

Figure 3-7: Mini 10-Pin and Mini 20-Pin Keyed Header Dimensions

User Manual For Cyclone LC Programmers

23

3.17

Target Headers For Part# CYCLONE-LC-ARM
PEmicro Part# CYCLONE-LC-ARM features 3 ports labeled A-C.

3.17.1

PORT A: 10-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices)

3.17.1.1 JTAG Pin Assignments

The Cyclone provides a keyed 10-pin 0.050-inch pitch double row connector for ARM targets. The location of the this header is indicated as PORT A in Figure 3-5. The 10-pin keyed mini connector pin definitions for JTAG mode are as follows:

10-Pin Keyed Mini Connector JTAG Mode Pin Assignments

PIN 1 - TVCC

TMS - PIN 2

PIN 3 - GND

TCK - PIN 4

PIN 5 - GND

TDO - PIN 6

PIN 7 - NC

TDI - PIN 8

PIN 9 - JTAG_MOD/NC* RESET - PIN 10

Note: * PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.

Cyclone LC programmers also support SWD Mode. This replaces the JTAG connection with a clock and single bi-directional data pin.

3.17.1.2 SWD Mode Pin Assignments

10-Pin Keyed Mini Connector SWD Mode Pin Assignments

PIN 1 - TVCC

TMS/SWDIO - PIN 2

PIN 3 - GND

TCK/SWCLK - PIN 4

PIN 5 - GND

NC* - PIN 6

PIN 7 - NC

NC* - PIN 8

PIN 9 - JTAG_MOD/NC** RESET - PIN 10

Note: *The pin is reserved for internal use within the PEmicro interface.

Note: ** PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.

SWD Mode is selected from the "Communication Mode" drop-down box in the Cyclone Image Creation Utility:

Figure 3-8: Communications Mode Selection
3.17.1.2.1 High-Performance Communications (FX ONLY) If high-performance options are available for the selected device they will appear in the "Shift Frequency in MHz" drop-down. Cyclone FX programmers are capable of high-performance communications when using certain ARM Cortex targets in SWD mode.
Note: Cyclone LC programmers cannot currently take advantage of high-performance options, although the frequencies appear in the display.

User Manual For Cyclone LC Programmers

24

Figure 3-9: High-Performance Options (FX ONLY)

3.17.2

PORT B: 20-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices)

3.17.2.1 JTAG Mode Pin Assignments

The Cyclone provides a keyed 20-pin 0.050-inch pitch double row connector for ARM targets. The location of the this header is indicated as PORT B in Figure 3-5. The 20-pin keyed mini connector pin definitions for JTAG mode are as follows:

20-Pin Keyed Mini Connector JTAG Mode Pin Assignments

PIN 1 - TVCC

TMS - PIN 2

PIN 3 - GND

TCK - PIN 4

PIN 5 - GND

TDO - PIN 6

PIN 7 - NC

TDI - PIN 8

PIN 9 - JTAG_MOD/NC** RESET - PIN 10

PIN 11 - NC

NC* - PIN 12

PIN 13 - NC

NC* - PIN 14

PIN 15 - GND

NC* - PIN 16

PIN 17 - GND

NC* - PIN 18

PIN 19 - GND

NC* - PIN 20

Note: *The pin is reserved for internal use within the PEmicro interface.

Note: ** PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.

3.17.2.2 SWD Mode Pin Assignments

Cyclone LC programmers also support SWD Mode. This replaces the JTAG connection with a clock and single bi-directional data pin.

20-Pin Keyed Mini Connector SWD Mode Pin Assignments

PIN 1 - TVCC

TMS/SWDIO - PIN 2

PIN 3 - GND

TCK/SWCLK - PIN 4

PIN 5 - GND

NC* - PIN 6

PIN 7 - NC

NC* - PIN 8

PIN 9 - JTAG_MOD/NC** RESET - PIN 10

PIN 11 - NC

NC* - PIN 12

PIN 13 - NC

NC* - PIN 14

PIN 15 - GND

NC* - PIN 16

PIN 17 - GND

NC* - PIN 18

PIN 19 - GND

NC* - PIN 20

Note: *The pin is reserved for internal use within the PEmicro interface.
Note: ** PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.

User Manual For Cyclone LC Programmers

25

SWD Mode is selected from the "Communication Mode" drop-down box in the Cyclone Image Creation Utility:
Figure 3-10: Communications Mode Selection 3.17.2.2.1 High-Performance Communications (FX ONLY)
If high-performance options are available for the selected device they will appear in the "Shift Frequency in M Hz" drop-down. Cyclone FX programmers are capable of high-performance communications when using certain ARM Cortex targets in SWD mode. Note: Cyclone LC programmers cannot currently take advantage of high-performance options, although the frequencies appear in the display.

Figure 3-11: High-Performance Options (FX ONLY)

3.17.3

PORT C: 20-Pin Debug Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices)

3.17.3.1 JTAG Mode Pin Assignments

The Cyclone provides a 20-pin 0.100-inch pitch double row connector for ARM targets. The location of the this header is indicated as PORT C under Part# CYCLONE-LC-ARM in Figure 3-5. The 20-pin standard connector pin definitions for JTAG mode are as follows:

20-Pin Standard Connector JTAG Mode Pin Assignments

PIN 1 - TVCC PIN 3 - TRST or NC PIN 5 - TDI PIN 7 - TMS PIN 9 - TCK PIN 11 - NC* PIN 13 - TDO PIN 15 - RESET PIN 17 - NC* PIN 19 - NC*

NC* - PIN 2 GND - PIN 4 GND - PIN 6 GND - PIN 8 GND - PIN 10 GND - PIN 12 GND - PIN 14 GND - PIN 16 GND - PIN 18 GND - PIN 20

Note: *The pin is reserved for internal use within the PEmicro interface.

3.17.3.2 SWD Mode Pin Assignments
Cyclone LC programmers also support SWD Mode. This replaces the JTAG connection with a clock and single bi-directional data pin.

20-Pin Standard Connector SWD Mode Pin Assignments

PIN 1 - TVCC PIN 3 - TRST or NC* PIN 5 - NC*

NC* - PIN 2 GND - PIN 4 GND - PIN 6

User Manual For Cyclone LC Programmers

26

PIN 7 - TMS/SWDIO PIN 9 - TCK/SWCLK PIN 11 - NC* PIN 13 - NC* PIN 15 - RESET PIN 17 - NC* PIN 19 - NC*

GND - PIN 8 GND - PIN 10 GND - PIN 12 GND - PIN 14 GND - PIN 16 GND - PIN 18 GND - PIN 20

Note: *The pin is reserved for internal use within the PEmicro interface.
SWD Mode is selected from the "Communication Mode" drop-down box in the Cyclone Image Creation Utility:

Figure 3-12: Communications Mode Selection
3.17.3.2.1 High-Performance Communications (FX ONLY) If high-performance options are available for the selected device they will appear in the "Shift Frequency in MHz" drop-down. Cyclone FX programmers are capable of high-performance communications when using certain ARM Cortex targets in SWD mode.
Note: Cyclone LC programmers cannot currently take advantage of high-performance options, although the frequencies appear in the display.

Figure 3-13: High-Performance Options (FX ONLY)

3.18

Target Headers For Part# CYCLONE-LC-UNIV
PEmicro Part# CYCLONE-LC-UNIV features 6 ports labeled A-H.

3.18.1

PORT A: 10-Pin Keyed Mini Connector (NXP Kinetis & S32 (ARM), other PEmicro-Supported ARM devices, Infineon TriCore)

3.18.1.1 JTAG Mode Pin Assignments

The Cyclone provides a keyed 10-pin 0.050-inch pitch double row connector for ARM targets. The location of the this header is indicated as PORT A in Figure 3-5. The 10-pin keyed mini connector pin definitions for JTAG mode are as follows:

10-Pin Keyed Mini Connector JTAG Mode Pin Assignments

PIN 1 - TVCC

TMS - PIN 2

PIN 3 - GND

TCK - PIN 4

PIN 5 - GND

TDO - PIN 6

PIN 7 - NC

TDI - PIN 8

PIN 9 - JTAG_MOD/NC* RESET - PIN 10

Note: * PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should

User Manual For Cyclone LC Programmers

27

be left as NC.

3.18.1.2 SWD Mode Pin Assignments

Cyclone LC programmers also support SWD Mode. This replaces the JTAG connection with a clock and single bi-directional data pin.

Note:

10-Pin Keyed Mini Connector SWD Mode Pin Assignments

PIN 1 - TVCC

TMS/SWDIO - PIN 2

PIN 3 - GND

TCK/SWCLK - PIN 4

PIN 5 - GND

NC* - PIN 6

PIN 7 - NC

NC* - PIN 8

PIN 9* - JTAG_MOD/NC** RESET - PIN 10

*The pin is reserved for internal use within the PEmicro interface.

Note: ** PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.

SWD Mode is selected from the "Communication Mode" drop-down box in the Cyclone Image Creation Utility:

Figure 3-14: Communications Mode Selection
3.18.1.2.1 High-Performance Communications (FX ONLY) If high-performance options are available for the selected device they will appear in the "Shift Frequency in MHz" drop-down. Cyclone FX programmers are capable of high-performance communications when using certain ARM Cortex targets in SWD mode.
Note: Cyclone LC programmers cannot currently take advantage of high-performance options, although the frequencies appear in the display.

Figure 3-15: High-Performance Options (FX ONLY)

3.18.1.3 DAP Connector Pin Assignments (Target Board Has Dedicated DAP Connector Port)

Users whose target board does not have a dedicated DAP Connector should refer instead to Port H in Section 3.20.8.3 - DAP Connector Pin Assignments (Target Board Does Not Have Dedicated DAP Connector Port).

The keyed 10-pin 0.050-inch pitch double row connector of the CYCLONE-LC-UNIV model supports Infineon TriCore targets (AUDOTM TC1xx and AURIXTM TC2xx/TC3xx). The location of the this header is indicated as PORT A in Figure 3-5. The 10-pin keyed mini connector pin definitions for DAP connectors are as follows:

10-Pin Keyed Mini Connector DAP Pin Assignments

PIN 1 - TVCC PIN 3 - GND

DAP1 - PIN 2 DAP0 - PIN 4

User Manual For Cyclone LC Programmers

28

Note:

PIN 5 - GND PIN 7 - NC PIN 9 - NC*

NC* - PIN 6 NC* - PIN 8 RESET - PIN 10

*The pin is reserved for internal use within the PEmicro interface.

3.18.2

PORT B: 20-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices)

3.18.2.1 JTAG Mode Pin Assignments

The Cyclone provides a keyed 20-pin 0.050-inch pitch double row connector for ARM targets. The location of the this header is indicated as PORT B in Figure 3-5. The 20-pin keyed mini connector pin definitions for JTAG mode are as follows:

20-Pin Keyed Mini Connector JTAG Mode Pin Assignments

PIN 1 - TVCC

TMS - PIN 2

PIN 3 - GND

TCK - PIN 4

PIN 5 - GND

TDO - PIN 6

PIN 7 - NC

TDI - PIN 8

PIN 9 - JTAG_MOD/NC** RESET - PIN 10

PIN 11 - NC

NC* - PIN 12

PIN 13 - NC

NC* - PIN 14

PIN 15 - GND

NC* - PIN 16

PIN 17 - GND

NC* - PIN 18

PIN 19 - GND

NC* - PIN 20

Note: *The pin is reserved for internal use within the PEmicro interface.

** PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.

3.18.2.2 SWD Mode Pin Assignments

Cyclone LC programmers also support SWD Mode. This replaces the JTAG connection with a clock and single bi-directional data pin.

20-Pin Keyed Mini Connector SWD Mode Pin Assignments

PIN 1 - TVCC

TMS/SWDIO - PIN 2

PIN 3 - GND

TCK/SWCLK - PIN 4

PIN 5 - GND

NC* - PIN 6

PIN 7 - NC

NC* - PIN 8

PIN 9 - JTAG_MOD/NC** RESET - PIN 10

PIN 11 - NC

NC* - PIN 12

PIN 13 - NC

NC* - PIN 14

PIN 15 - GND

NC* - PIN 16

PIN 17 - GND

NC* - PIN 18

PIN 19 - GND

NC* - PIN 20

Note: *The pin is reserved for internal use within the PEmicro interface.
** PIN9: Users of NXP i.MX processors are recommended to connect the JTAG_MOD signal to this pin to allow programming when secure JTAG is enabled. For all other processors, this pin should be left as NC.
SWD Mode is selected from the "Communication Mode" drop-down box in the Cyclone Image Creation Utility:

User Manual For Cyclone LC Programmers

29

Figure 3-16: Communications Mode Selection
3.18.2.2.1 High-Performance Communications (FX ONLY) If high-performance options are available for the selected device they will appear in the "Shift Frequency in MHz" drop-down. Cyclone FX programmers are capable of high-performance communications when using certain ARM Cortex targets in SWD mode.
Note: Cyclone LC programmers cannot currently take advantage of high-performance options, although the frequencies appear in the display.

3.18.3

Figure 3-17: High-Performance Options (FX ONLY)
PORT C: 14-Pin Debug Connector (MPC55xx-57xx, SPC5, DSC, S32 (Power)) The Cyclone provides a standard 14-pin 0.100-inch pitch dual row 0.025-inch square header for MPC55xx-57xx, DSC (MC56F8xxx), S32R, or STMicroelectronics' SPC5 targets. The location of the this header is indicated as PORT C in Figure 3-5.

MPC55xx-57xx, SPC5, or S32 (Power) Pinout

TDI 1

2 GND

TDO 3

4 GND

TCK 5

6 GND

NC 7

8 NC

RESET 9 10 TMS

VDDE7 11 12 GND

RDY 13 14 JCOMP

DSC Pinout

TDI 1

2 GND

TDO 3

4 GND

TCK 5

6 GND

NC 7

8 NC/KEY

RESET 9 10 TMS

VDD 11 12 GND

NC* 13 14 TRST

*The pin is reserved for internal use within the PEmicro interface.

3.18.3.1 BERG14-to-MICTOR38 Optional Connector
PEmicro offers a 14-pin BERG to 38-pin MICTOR adapter, sold separately, that may be used on Port C of the Cyclone LC. The PEmicro part number is BERG14-TO-MICTOR38.

User Manual For Cyclone LC Programmers

30

3.18.4

Figure 3-18: BERG14-TO-MICTOR38 Adapter (Sold Separately)
PORT D: 26-Pin Debug Connector (ColdFire V2/3/4)
The Cyclone provides a standard 26-pin 0.100-inch pitch dual row 0.025-inch square header for ColdFire MCF52xx/53xx/54xx family of microprocessors. This port connects to the target hardware using either the ColdFire extension cable for synchronous ColdFire targets such as MCF5272 & MCF5206E (PEmicro part# CABLE-CF-ADAPTER, sold separately), or a standard 26-pin ribbon cable for asynchronous ColdFire targets (included). Please refer to each processor's user manual to identify whether it is a synchronous or asynchronous interface. The location of the this header is indicated as PORT D in Figure 3-5.

ColdFire V2/3/4 Pinout

N/C 1

2 BKPT

GND 3

4 DSCLK

GND 5

6 NC*

RESET 7

8 DSI

VCC 9 10 DSO

GND 11 12 PST3

PST2 13 14 PST1

PST0 15 16 DDATA3

DDATA2 17 18 DDATA1

DDATA0 19 20 GND

N/C 21 22 N/C

GND 23 24 CLK

VCC 25 26 TEA

*The pin is reserved for internal use within the PEmicro interface.

The ColdFire adapter for Synchronous targets and ribbon cable for Asynchronous targets is pictured below:

Figure 3-19: ColdFire Adapter (part# CABLE_CF_ADAPTER (Rev. B), for synchronous ColdFire

User Manual For Cyclone LC Programmers

31

targets, sold separately)

Figure 3-20: ColdFire Ribbon Cable (for asynchronous ColdFire targets, included with Cyclone)

3.18.5

PORT E: 16-Pin Debug Connector (MON08)

The Cyclone provides a 16-pin 0.100-inch pitch double row connector for MON08 targets. The location of the this header is indicated as PORT E in Figure 3-5. The MON08 header adopts the standard pin-out from MON08 debugging with some modifications. The general pin-out is as follows:

MON08 Signals

PIN 1 - NC* PIN 3 - NC** PIN 5 - NC* PIN 7 - NC* PIN 9 - NC* PIN11 - NC* PIN13 - OSC PIN15 - Vout

GND RST IRQ MON4 MON5 MON6 MON7 MON8

- PIN 2 - PIN 4 - PIN 6 - PIN 8 - PIN10 - PIN12 - PIN14 - PIN16

*The pin is reserved for internal use within the PEmicro interface.

**The pin is reserved for internal use within the PEmicro interface only when using an MR8 target.

3.18.6

PORT F: 6-Pin Debug Connector (RS08, HCS08, HC(S)12(X), S12Z, ColdFire +/V1, STM8 w/ adapter)
The Cyclone provides a standard 6-pin 0.100-inch pitch dual row 0.025-inch square header for ColdFire V1, S12Z, 68(S)12(X), 68HCS08, RS08, and STMicroelectronics' STM8 targets. The location of the this header is indicated as PORT F in Figure 3-5. The header uses the NXP standard pin configuration, listed here for reference:

ColdFire V1, 68(S)12(X), 68HCS08, and RS08 Signals

PIN 1 - BKGD PIN 3 - NC PIN 5 - NC

GND - PIN 2 RESET - PIN 4
TVCC - PIN 6

S12Z Signals Note:* indicates optional signal

PIN 1 - BKGD PIN 3 - PDO* PIN 5 - PDOCLK*

GND - PIN 2 RESET - PIN 4
TVCC - PIN 6

User Manual For Cyclone LC Programmers

32

6-Pin STM8 Signals

PIN 1 -SWIM** PIN 3 - NC* PIN 5 - NC*

GND - PIN 2 RESET - PIN 4
TVCC - PIN 6

*The pin is reserved for internal use within the PEmicro interface.

** All the signals are direct connect except the SWIM line which requires a 680 Ohm pull-up

PEmicro also offers a separate STM8 adapter (part# CU-CUFX-STM8-ADPT) that can be plugged into the 6-pin header of the Cyclone (see Figure 3-21). The adapter offers 4 pins signals from an ERNI connector.

4-Pin STM8 Signals

(Requires STM8 Adapter, sold separately)

PIN 1 - TVCC PIN 3 - GND

SWIM - PIN 2 RESET - PIN 4

Figure 3-21: STM8 Adapter: 1) Bottom, 2) Top, 3) Connected To 6-Pin Header of Cyclone_Universal (Adapter Sold Separately)

3.18.7

PORT G: 10-Pin Debug Connector (Power MPC5xx/8xx)
The Cyclone provides a standard 10-pin 0.100-inch pitch dual row 0.025-inch square header for Power MPC5xx/8xx BDM targets. The location of the this header is indicated as PORT G in Figure 3-5.
Power MPC5xx/8xx BDM Pinout
NC* 1 2 SRESET# GND 3 4 DSCLK GND 5 6 NC* HRESET# 7 8 DSDI VDD 9 10 DSDO

*The pin is reserved for internal use within the PEmicro interface.

3.18.8

PORT H: 20-Pin Debug Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM devices, Infineon TriCore)

3.18.8.1 JTAG Mode Pin Assignments
The Cyclone provides a 20-pin 0.100-inch pitch double row connector for ARM targets. The location of the this header is indicated as PORT H under Part# CYCLONE-LC-UNIV in Figure 3-5. The 20-pin standard connector pin definitions for JTAG mode are as follows:

User Manual For Cyclone LC Programmers

33

20-Pin Standard Connector JTAG Mode Pin Assignments

PIN 1 - TVCC PIN 3 - TRST or NC* PIN 5 - TDI PIN 7 - TMS PIN 9 - TCK PIN 11 - NC* PIN 13 - TDO PIN 15 - RESET PIN 17 - NC* PIN 19 - NC*

NC - PIN 2* GND - PIN 4 GND - PIN 6 GND - PIN 8 GND - PIN 10 GND - PIN 12 GND - PIN 14 GND - PIN 16 GND - PIN 18 GND - PIN 20

*The pin is reserved for internal use within the PEmicro interface.
3.18.8.2 SWD Mode Pin Assignments Cyclone LC programmers also support SWD Mode. This replaces the JTAG connection with a clock and single bi-directional data pin.

20-Pin Standard Connector SWD Mode Pin Assignments

PIN 1 - TVCC PIN 3 - TRST or NC* PIN 5 - NC* PIN 7 - TMS/SWDIO PIN 9 - TCK/SWCLK PIN 11 - NC* PIN 13 - NC* PIN 15 - RESET PIN 17 - NC* PIN 19 - NC*

NC* - PIN 2 GND - PIN 4 GND - PIN 6 GND - PIN 8 GND - PIN 10 GND - PIN 12 GND - PIN 14 GND - PIN 16 GND - PIN 18 GND - PIN 20

*The pin is reserved for internal use within the PEmicro interface.
SWD Mode is selected from the "Communication Mode" drop-down box in the Cyclone Image Creation Utility:

Figure 3-22: Communications Mode Selection
3.18.8.2.1 High-Performance Communications (FX ONLY) If high-performance options are available for the selected device they will appear in the "Shift Frequency in MHz" drop-down. Cyclone FX programmers are capable of high-performance communications when using certain ARM Cortex targets in SWD mode.
Note: Cyclone LC programmers cannot currently take advantage of high-performance options, although the frequencies appear in the display.

User Manual For Cyclone LC Programmers

34

Figure 3-23: High-Performance Options (FX ONLY)

3.18.8.3 DAP Connector Pin Assignments (Target Board Does Not Have Dedicated DAP Connector Port)

Users whose target board has a dedicated DAP Connector should instead refer to Port A in Section 3.20.1.3 - DAP Connector Pin Assignments (Target Board Has Dedicated DAP Connector Port).

If the user's target board does not have a dedicated DAP connector port, the user may choose to wire pins to the 20-pin 0.100-inch pitch double row connector of the CYCLONE-LC-UNIV model (can be used with Infineon TriCore targets AUDOTM TC1xx and AURIXTM TC2xx/TC3xx). The location of the this header is indicated as PORT H in Figure 3-5. The 20-pin standard connector pin definitions for DAP connectors are as follows:

20-Pin Standard Connector JTAG Mode Pin Assignments

PIN 1 - TVCC PIN 3 - TRST or NC* PIN 5 - NC* PIN 7 - DAP1 PIN 9 - DAP0 PIN 11 - NC* PIN 13 - NC* PIN 15 - RESET PIN 17 - NC* PIN 19 - NC*

NC - PIN 2* GND - PIN 4 GND - PIN 6 GND - PIN 8 GND - PIN 10 GND - PIN 12 GND - PIN 14 GND - PIN 16 GND - PIN 18 GND - PIN 20

*The pin is reserved for internal use within the PEmicro interface.
Note: Pin3 - TRST needs to be high at power on reset release for enabling DAP, so short circuiting TRST to VDD may be advised.

3.19

Ribbon Cable
Cyclone LC programmers communicate with the target through ribbon cables. The ribbon cables for standard debug connectors have a 0.100-inch centerline dual row socket IDC assembly (not keyed). The ribbon cables for 10- and 20-pin mini debug connectors have a 0.050-inch centerline dual row socket IDC assembly (keyed). The ribbon cables are designed such that the Cyclone's Debug Connector has the same pinout as the Target Header, i.e., Pin 1 of the Cyclone's Debug Connector is connected to Pin 1 of the Target Header. As an example, Figure 3-25 sketches the connection mechanism (looking down into the sockets) for a 14-pin ribbon cable. Ribbon cables for other supported architectures use a similar scheme, but may have more or fewer pins.

User Manual For Cyclone LC Programmers

35

Figure 3-24: Ribbon Cable Example Diagram, When Looking Into IDC Socket

User Manual For Cyclone LC Programmers

36

4 TARGET POWER MANAGEMENT
Different target devices may require different power schemes which depend on the design of the target board, target voltages, and even the device architecture. PEmicro has designed the Cyclone LC to be capable of powering a target before, during, and after programming. Power can be sourced at many voltage levels from the Cyclone itself, or sourced by an external power supply and switched by the Cyclone.

Figure 4-1: Five different paths to power a target
The versatility of the Cyclone power scheme gives the user the utmost flexibility, and includes the following features:
· Provides power through a power jack or through the debug connector
· Provides internally generated voltage from 1.6v-5.5v at up to 500mA
· Switches an external power supply voltage, up to 24V at 1amp
· Selectively powers the target before, during, and after programming
· Powers down the target connections between programming operations
· Uses power switching to aid entry into debug mode for certain targets
· Provides target voltage and current measurement capabilities
If target power is required, each target board may vary where the power is sourced from, externally or internally, and how it is channeled to the target: through the debug header or to a separate connector to the board. Power that is passed through and managed by the Cyclone goes through power relays so it can be power cycled. This is extremely useful because it also allows the power to be off during setup and automatically powered on by the Cyclone for programming. For some devices, the process of entering debug mode requires that the device be powered down and powered back up. Power can also be left in a desired power state, either on or off.

4.1

Cyclone Configuration

There are two different places Power Management is configured and they should be matched: first, by the jumpers on the Cyclone LC, and second, in the setup of the programming image. The Cyclone jumpers are the most important because they are the physical connection to the target. The Cyclone has an easy access panel that reveals debug header connections for a variety of different architectures, and a 2x4 jumper block for configuring power management of the target. The specific location of the jumpers is indicated by the label POWER JUMPERS in Figure 4-3. This set of 4 jumpers can be used to set 5 different power management schemes for the target.

User Manual For Cyclone LC Programmers

37

Note: If these jumpers are not set correctly, the Cyclone will not function as intended. 1 Target is powered independently

Power provided externally (center +) and 2 managed by Cyclone, power out to debug
ribbon cable.
Power provided externally (center +) and 3 managed by Cyclone, power out to 2.5 mm
output jack (center +)

4

Power provided by Cyclone, power out to debug ribbon cable

5

Power provided by Cyclone, power out to 2.5 mm output jack (center +)

Figure 4-2: Cyclone Power Schemes & Corresponding Jumper Settings
The bottom edge of the Cyclone LC has a Power In jack for externally provided power, and the top edge of the Cyclone has Power Out jack, for when power schemes including these are used (see Figure 4-3). One of the provided ribbon cables is connected to the appropriate debug header based on the specific target architecture.

Figure 4-3: Cyclone Hardware Features: Power Jumpers and Target Headers The power settings that are set by the jumpers are a physical connection and take precedence.

User Manual For Cyclone LC Programmers

38

After the basic hardware setup, target power and voltage settings are also set in the creation of a SAP (stand-alone programming) image. At a minimum the SAP image contains all the commands to Erase, Program, and Verify a programming image. More sophisticated power selections in the SAP image can control the relays, target voltage, delays, and power down after SAP operations, as shown in the selection dialog.

4.2
4.2.1

Figure 4-4: Target Power & Voltage Settings
Target voltages (with appropriate jumper settings) in the range of 1.6 to 5.5 volts may be provided. There is also the option to select the internal Cyclone relays to power cycle the Cyclone during programming, and set the length of delays during power up and down. This is extremely useful to make sure the power is off when hooking up the target. Power cycling is especially important for architectures that require it to enter debug mode. The SAP image settings may even be used to turn off the target power once programming is completed, to ensure that the microcontroller is left in a halted state and not running.
Cyclone Setup
Below is a tutorial that demonstrates how to set up the Cyclone LC in each of the 5 power configurations. A very common configuration is the independently powered target. In this power scenario, the Cyclone will detect and use the power on the target for the appropriate debug communication voltages.
Independently Powered Target
In the simplest and most common scenario, no jumpers are set, so the target is powered independently from the Cyclone. No power is passed through the debug header, just the standard debug signals. The Cyclone automatically detects the target power and sets the debug signals to match.

4.2.2

Figure 4-5: Independently Powered Target
Power provided by the Cyclone to the debug cable
It is also possible for the Cyclone to generate power through an internal regulator in the range of 1.6 to 5.5 Volts. In the jumper configuration below, the Cyclone generates the power through a voltage regulator, and passes it through the power relays and out through the debug ribbon cable, which is set up during the SAP image creation. There is only one connection to the target processor which will handle both the communication and the power. In this scenario, external power must not be connected to the Power In jack since it is already being provided.

User Manual For Cyclone LC Programmers

39

4.2.3

Figure 4-6: Power Provided by the Cyclone to the Debug Cable
External Power passed through the Cyclone and out 2.5 mm barrel port
It is also possible to provide external power, passed through the Cyclone power relays, and back out to be available to power the target board externally. This is useful when the user wants to control the power to the target and the target board has an external power connector. Setting a single jumper will connect the barrel port input connector on the bottom edge of the Cyclone, through the relays, to a matched 2.5 mm barrel port output connector on the top edge of the Cyclone, so that the power can be routed into and back out of the Cyclone.

4.2.4

Figure 4-7: External Power Passed Through the Cyclone and Out 2.5 mm Barrel Port
External Power passed through the Cyclone to the debug cable
In a slightly different scenario, the user may wish to provide power to the target through the debug cable. On the bottom edge of the Cyclone is a 2.5 mm Power In port barrel which will pass power through target relays which lets the Cyclone take control of the power cycling during programming. This simple setup requires only an input to the Cyclone and a single ribbon cable connection to the target board that handles both communication and power. The external power provided must be between 1.6 to 5.5 volts.

User Manual For Cyclone LC Programmers

40

4.2.5

Figure 4-8: External Power Passed Through the Cyclone to the Debug Cable
Power provided by the Cyclone and out 2.5 mm barrel port
In a slightly different scenario, the user may wish to have the Cyclone provide power, but power the target via an external connector on the target. The voltage supplied to the target is determined by the settings in the SAP image. When generating the SAP image the Cyclone relays must be selected as well as the correct voltage level for the target.

Figure 4-9: Power Provided by the Cyclone and Out 2.5 mm Barrel Port

4.3

Setup Reminders

The most important step when providing power out to a target is to check the Cyclone's jumper settings to make sure they match the intended power setup. The jumpers control the power settings which determine how power is supplied, regardless of the SAP image settings. If the jumpers are set for power to be provided through the Cyclone, and the target is externally powered, this is a conflict and may cause damage to the board.

In the case where power is being supplied through the Cyclone and the target is not being powered on, the user should first check the jumper settings to make sure they match the intended power setup. Second, the user should check to make sure the SAP image has the `Use Cyclone Relays' box checked with the appropriate voltage level selected.

User Manual For Cyclone LC Programmers

41

5 TOUCHSCREEN LCD MENU
This chapter describes the Cyclone's touchscreen LCD menu. Figure 5-1 shows an overview of the menu structure.
Note: This menu will change as features are added to the Cyclone LC, so if your menu does not match what is displayed here, please check PEmicro's website, www.pemicro.com, for a user manual containing the latest LCD Menu operations information.

5.1

Home Screen

The home screen appears when the Cyclone LC is powered on, or when the button is tapped.

Home

5.1.1

Icons A row of icons in the upper right corner indicates the status of various attributes of the Cyclone.
Note: The user may tap on the row of icons to view the meaning of each of the currently displayed icons. Cyclone Unit Status: Ok / Bad

Programming Status: Ready / Busy

USB-To-PC Enumerated: Yes / No

Real-Time clock Enabled & Working: Yes / No

Cyclone Power Relays: Closed / Open Target Device Is Powered*: Yes / No
SDHC Memory Card: None / Valid / Unformattted / Reset Cyclone**

5.1.2

* Target Device Is Powered - "Yes" indicates that the Cyclone LC detects power on the Vcc pin of the target device programming header. ** SDHC Memory Card (Requires SDHC Activation License) - "Reset Cyclone" indicates that the Cyclone needs to be reset before the SDHC card will register as Valid. The user can push the Reset button which is located on the front side of the Cyclone, below the LED indicators.
Configurable Display Area The main area of the home screen can be configured to optionally display the following information, by using the Cyclone IP Configuration Utility (see Section 5.2.3.5.4 - Configure Home Screen): 1. Firmware version of the Cyclone (always shown). 2. IP address assigned to the Cyclone. 3. Name assigned to the Cyclone. 4. Number of programming images in the Cyclone's memory. 5. Name of the selected programming image. 6. First serial number associated with the selected image 7. Current status. 8. Results of the last operation performed. 9. Time and date. 10. Status Window and Main Menu button (always shown). 11. Programming count & limit

User Manual For Cyclone LC Programmers

42

5.1.3 5.1.4
5.1.5

12.
Status Window The status window appears in the lower left corner of the home screen and displays the results of programming operations.
Error Information Icon When the Cyclone experiences an error during programming operations, the Info icon will appear to the left of the Menu button (or AUX button, if configured). Info Icon:
Press the Info icon to view a detailed description of the error.
AUX Button (Appears If Configured) The Cyclone allows the user to add an Auxiliary (AUX) button to the home screen which will perform a specific function when pressed. The specific function is chosen by the user when the AUX button is configured. The AUX button will appear on the home screen to the left of the "Menu" button, in the lower right corner of the home screen.

Figure 5-1: AUX Button On Home Screen (configured to perform CRC32 function) For information on how to configure the AUX button, see Section 5.2.4 - Status.

5.2

Main Menu

The Main Menu is accessible by pressing the "Menu" button when the Home Screen is displayed. The Main Menu contains the following selections:

User Manual For Cyclone LC Programmers

43

Figure 5-2: Main Menu Structure

User Manual For Cyclone LC Programmers

44

5.2.1

Select Programming Image
Displays a list of the available programming images so that the user may select one for programming. Images in the Cyclone's internal memory are preceded by the designation "IN" and numbered sequentially, i.e., IN1: first image name, IN2: second image name. If the SDHC port of the Cyclone is activated and contains a memory card (and the SDHC License Activation is installed), any programming images that reside on the SD card will be preceded by the designation "EX" in similar fashion.
Encrypted (eSAP) images will display a lock icon to the left of the image description. If the ImageKey needed to decrypt an eSAP image is missing from the Cyclone, the image will appear grayed out. and cannot be selected for programming until the appropriate ImageKey is loaded onto the Cyclone (see image #2 in Figure 5-3).

Figure 5-3: Lock Icon Denotes Encrypted Images
You may tap the appropriate image to select it. The image name shown is the one specified in the Cyclone Configuration Utility when saving the image to the Cyclone/SD card.

5.2.2

Current Image Options
This menu presents options that allow the user to select or configure programming images on the Cyclone LC.

5.2.2.1

Execute Image Function
Execute Specific SAP Function presents four Stand-Alone Programming functions that you may execute by tapping the function that you wish to execute:

5.2.2.1.1 Launch Programming
This allows the user to execute the programming function. The Cyclone LC will program the target device, if able, using the currently selected programming image. This is functionally equivalent to pressing the Start button.

5.2.2.1.2 Verify Data In Target Performs a verify function on the data that has been programmed into the target device.

5.2.2.1.3 Toggle Power Toggles the target power and makes sure all ports are driven to debug mode level.

5.2.2.1.4 Power Cycle Device To Run User Code Toggles the target power and maintains tri-state mode for all signals.

5.2.2.1.5 Validate Image CRC32 Allows the user to perform a CRC32 validation on the currently selected programming image.

User Manual For Cyclone LC Programmers

45

5.2.2.1.6 Launch Image Programming Launches the selected programming image. Replaces the hardware Start Button.

5.2.2.2

Set Image Validation
Allows the user to choose between two validation settings: 1) validate the image each time the Start button is pressed, or 2) do not validate the image.

5.2.2.3

Serial Numbers
Displays the serial number information associated with the currently selected programming image. If there is none, it will display, "This Image Contains No Serial Numbers." There may be one or more Serial Files associated with the image. The user can click on a specific Serial File name to see the following information about that Serial File:
· UID - Unique identifier of the serial number
· Next Serial # ASCII - Next serial number to be programmed (shown in ASCII format)
· Algorithm ID - Displays the algorithm ID of the serial file
· CS ID - Displays the ID of the CS (Choose Serial) command in the SAP file.

Figure 5-4: Serial File Selection
The user can also click on "Modify Serial Number" to edit that serial number. It is possible to Decrease or Increase the Next Serial by -10, -1, +1, +10. This is often done to address issues in the production process, such as during initial setup.

Figure 5-5: Increase or Decrease Serial Number

The adjustment buttons will display "Increase Not Allowed" and "Decrease Not Allowed" if the image/algorithm/CS file that the user has selected does not allow for this operation.

Note:

Older serial files are specific to one programming image, unlike PEmicro's current serial files. If viewing Serial Number info for an image that references one or more older serial files, the Cyclone will not show links to the serial files but will instead display serial number info for the first serial file. The user can then Modify Next Serial to change the next serial number, or click MORE at the

User Manual For Cyclone LC Programmers

46

bottom to proceed to the next serial file (if any).

Figure 5-6: Serial Number View With Older Serial Files (CS IDs #1 & #2)

5.2.2.4

Show Image Restriction Stats (Requires FX or ProCryption Security Activation)
Displays current statistics, if any, for Image Programmed Count & Maximum Allowed, Errors Logged & Maximum Allowed, and Date Range Allowed. These limits can be set in the Security Features section of the Cyclone Image Creation Utility (see Section 6.1.10.2 - Image Restrictions).
Note: When Current Image Stats is displayed as a home screen item, only Image Programmed Count & Maximum Allowed are displayed on the home screen.

5.2.3

Configure Cyclone Settings
Presents options that allow the user to choose to configure the Cyclone LC network settings, time/ date settings, and LCD touchscreen display settings, or to set the display to dynamic.

5.2.3.1

Edit Cyclone Name
Allows the user to edit the name of the Cyclone using the on-screen keyboard. Click "Done" to save the new Cyclone name or "Cancel" to exit without saving a new Cyclone name. This name will be displayed on the Cyclone LC home screen if the Cyclone is configured to do so.

5.2.3.2

Configure Network Settings
Presents options that allows the user to view or edit various IP settings, toggle the IP settings between static and dynamic, and re-name the Cyclone LC.

5.2.3.2.1 Show Current IP Settings
This menu allows you to view the Cyclone LC IP address, Mask, and Gateway, and MAC address. You may also tap these entries to edit, as long as the Cyclone is set to Static IP mode.
Dynamic vs. Static
There are two schemes for assigning IP addresses. One is the Static IP addressing mode. This involves the user manually setting the IP address for every device on the network. In this case, it falls to the user to ensure the IPs assigned do not conflict and are within the boundaries of the network. The other is the Dynamic Host Configuration Protocol (DHCP). This involves setting up a separate server to manage the IP addresses. The server is given a list of valid IP addresses for the network. Using a predetermined set of rules, each new device that wishes to connect to the network is given an IP address by the server. This takes the task of managing the validity and uniqueness of IP addresses out of the user's hands and relegates it to the server. Cyclone LC programmers are capable of using either Static IP addressing or DHCP.

5.2.3.2.2 Edit Static IP Settings
This menu allows you to edit the Cyclone's IP address, Mask, and Gateway, and view the Cyclone's MAC address. If you are unable to edit these values, you may wish to check to be

User Manual For Cyclone LC Programmers

47

certain that the Cyclone is not set to Dynamic IP mode.
IP
Edit IP Numbers allows the user to set an IP number for the Cyclone. The current IP number is displayed on the second line. Tap a number to edit and use the touchscreen keyboard to set the new number. When you are finished, hit Done. If you change your mind and decide not to save, hit Cancel to leave the IP number as is and return to the Main Menu.
Mask
Edit IP Mask allows the user to set an IP Mask for the Cyclone. The current IP Mask is displayed on the second line. Use the Up/Down buttons to scroll through the characters. To select a character, hit the Select button. When you are finished, scroll through the characters until you reach the -> (right-arrow) character. Selecting this character will complete the process. The default IP mask is 255.255.255.0.
Gateway
Edit IP Gateway allows the user to set the IP Gateway for the Cyclone. The current IP Gateway is displayed on the second line. Use the Up/Down buttons to scroll through the characters. To select a character, hit the Select button. When you are finished, scroll through the characters until you reach the -> (right-arrow) character. Selecting this character will complete the process.
MAC Address
Show MAC Address displays the current MAC address for the Cyclone.

5.2.3.2.3 Enable/Disable Dynamic IP
Allows the user to toggle the Cyclone configuration between utilizing a Static IP address or a Dynamic IP address. The user must reset the Cyclone LC after changing from Static to Dynamic or vice-versa. The reset button on the front side of the unit may be used.

5.2.3.3

Configure Time Settings (Cyclone Time / Real Time Clock)
The Cyclone LC is equipped with a Real Time Clock (RTC) module designed to keep accurate timing even when the Cyclone is turned off. The Date & Time are displayed on the home screen.
This menu presents options that allow the user to configure the Cyclone's various date/time/ timezone settings, including formatting options.

5.2.3.3.1 Modify Date / Time
1. Update Time from Internet - Connects to an SNTP server, fetches the current time, and saves it to the Cyclone. When executed it displays a message that this can freeze the Cyclone for up to 3 minutes ­ This is due to an invalid ARP response due to a bad gateway configuration. Proper configuration will ensure the problem is resolved. If the network connection is not configured/connected this displays a message that the time failed to update. If it is successful no message is displayed.
2. Set Time Zone Hours - Allows you to set the timezone offset, in hours +/-, from GMT time
3. Set Time Zone Minutes - Allows you to set the timezone offset, in minutes +/-, from GMT time

5.2.3.3.2 Set Time-Date Display Allows you set the Cyclone's Time-Date Display to one of the following configurations: 1. Display Date Only 2. Display Time Only 3. Display Date and Time

User Manual For Cyclone LC Programmers

48

5.2.3.3.4 Set Date Formatting Allows you to select how the date is displayed. The options are: 1. YYYY-MM-DD 2. MM-DD-YYYY 3. DD-MM-YYYY 4. MM/DD/YYYY

5.2.3.3.5 Set Time Formatting Allows you to select how the time is displayed. The options are: 1. HH:MM (24-hour) 2. HH:MM (AM/PM) 3. HH:MM:SS (24-hour) 4. HH:MM:SS (AM/PM)

5.2.3.4

Configure AUX Button
Allows the user to configure an auxiliary (AUX) button which (if configured) will be labeled appropriately and displayed to the left of the Menu button on the Cyclone's touchscreen LCD. When pressed, the AUX button will perform the task for which it has been configured. The options that may be assigned to the AUX button are:
1. No Operation - No operation is assigned to the AUX button and it will not be displayed on the LCD screen.
2. Perform Verify Only - Verifies the data on the target device against the data in the programming image.
3. Toggle Power - Toggles the Cyclones power relays off/on.
4. Validate Image CRC32 - Validates the CRC32 of the data on the target device against that of the data in the programming image.
5. Power Cycle Device To Run User Code - Toggles the target power and maintains tri-state mode for all signals.
6. Launch Image Programming - Launches the selected programming image. Replaces the hardware Start Button.

5.2.3.5

Configure Screen
This menu presents options that allow the user to adjust or customize the Cyclone's LCD touchscreen display in various ways.

5.2.3.5.1 Change Screen Brightness
Allows the user to adjust the brightness of the LCD touchscreen. The "Increase" and "Decrease" buttons will raise or lower the brightness level, respectively, in increments of 10%. Brightness can be adjusted from between 100% - 10%. Press "Done" to exit.

5.2.3.5.2 Calibrate Screen
Allows the user to click on specified points on the LCD touchscreen in order to calibrate the accuracy of the touch function. Follow the on-screen instructions.

5.2.3.5.3 Set Progress Details
This configures the display to present more detailed information during the progress of programming, including the specific programming steps that are performed and specific information about the programming and verifying procedure. The user may select "Show Details, Keep Last Progress On," "Show Progress Details," or "Hide Progress Details."

User Manual For Cyclone LC Programmers

49

5.2.3.5.4 Configure Home Screen
This menu allows you to choose what information to display on Lines 2-8 of the home screen. Available elements to display consist if information such as: the current IP address, the Cyclone name, the number of images, etc. In this way the user can customize the display to provide the information that they find most useful. There is a separate button for each of Lines 2-8. Tapping on the button for a specific Line brings up a list of elements that you can choose to display on that Line of the home screen. If the list of elements is greater than one page, tap the More button to view the rest of the available elements. Tap the element that you want to display on that line and then tap Done to save your selection.

5.2.3.6

Configure Storage
This menu selection allows the user to format the Cyclone's internal memory. This menu will also allow the user to format an SD card located in the Cyclone's memory expansion slot if the SDHC Port Activation License is installed. Select "Format Internal Storage" or "Format External SD Card". The user will be prompted to ensure that they wish to format the corresponding memory. Tap "Yes" to format, or "Cancel" to go back to the previous menu option without formatting the memory.

5.2.3.7

Enable/Disable Start Button
This menu option gives the user the option to disable the physical Start Button. Programming can then be initiated via the Cyclone Control Suite, or by a digital start button on the Cyclone screen if you have the AUX button set to the "Launch Image Programming" option.
The physical Start Button can always be re-enabled via this same menu toggle.

5.2.4

Status
This menu contains a selection that allow the user to view status information regarding various aspects of the Cyclone. This menu will likely be expanded with future updates.

5.2.4.1

Show Current IP Settings
Allows the user to view the Cyclone's Current IP Mode, IP Address, Mask, Gateway, and MAC Address.

User Manual For Cyclone LC Programmers

50

6 CREATING AND MANAGING PROGRAMMING IMAGES
The Cyclone Image Creation Utility is used to create programming images which may be loaded into the Cyclone. The user creates programming images based on data sets to be programmed and programming instructions which are all self contained. The next step is to download these programming images to the Cyclone via the GUI, Console, or SDK. Programming can then be launched either manually via the button, or automatically via the Console.exe or SDK. Learn about how to download and launch programming images in CHAPTER 8 - CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE).
Note: The Cyclone Image Creation Utility is Windows only. Users that wish to manage/automate programming via macOS/Linux will need a Windows platform to create programming images.

Note:

Cyclone LC programmers, or Cyclone LC programmers with the ProCryption Security Activation License, can also use the The Cyclone Image Creation Utility to encrypt programming images, such that only Cyclones with a specific key can decrypt and program these images. Instructions on how to encrypt using the Cyclone Image Creation Utility are found in Section 6.1.10.1 - SAP Image Encryption. A more in-depth description of the encryption process is available in CHAPTER 11 - SAP IMAGE ENCRYPTION.
If the user wishes to use a programming image created with an earlier generation Cyclone (such as the Cyclone PRO or MAX, or the Cyclone for ARM devices Rev. A/B) they should first convert the image using the conversion utility described in CHAPTER 14 - TROUBLESHOOTING.

6.1

Cyclone Image Creation Utility

This section describes in detail how use the Cyclone Image Creation Utility, shown in Figure 6-1, to configure, create, and save a SAP image that will be used for stand-alone programming with the Cyclone LC. The Cyclone LC does not require a target to be connected when it is being configured. However, the Cyclone must be powered on and one of the communications interfaces must be connected to the Cyclone if an image is to be stored on it.

User Manual For Cyclone LC Programmers

51

6.1.1

Figure 6-1: Cyclone Image Creation Utility
Specify CPU Manufacturer
The user should select the manufacturer of their target device from the drop-down list. Cyclone LC programmers support ARM Cortex devices from several manufacturers, including NXP's Kinetis and LPC devices. For a complete index of PEmicro-supported ARM Cortex devices, please view pemicro.com/arm. If you are using PEmicro Part# CYCLONE-LC-UNIV, this Cyclone also supports these 8-16/32-bit architectures: Kinetis, LPC, S32, MPC55xx-57xx), MPC5xx/8xx, DSC, S12Z, RS08, S08, HC08, HC(S)12(X), and ColdFire. It also supports Infineon TriCore (AUDOTM TC1xx and AURIXTM TC2xx/ TC3xx) and STMicroelectronics' SPC5 & STM8 (with STM8 adapter). Figure 6-2 shows the Specify CPU Manufacturer drop-down box. The options are:
· ARM-based (All Manufacturers)
· NXP
· STMicroelectronics
· Infineon

User Manual For Cyclone LC Programmers

52

Figure 6-2: Specify CPU Manufacturer

6.1.1.1

ARM-Based Devices
If the user chooses "ARM Based (All Manufacturers)" they should then select their specific device. A recently used device can be selected from the Device drop-down box on the left (see Section 6.1.1.3 - Device Box). The user may also click the "Select New Device" button. The Device Selection window will then appear. This dialog directs the user how to navigate the device tree to select their ARM device.

Figure 6-3: Device Selection - Drill Down To Specific Target Device

6.1.1.2

NXP or STMicroelectronics Devices
If the user chooses NXP or STMicroelectronics from the Specify CPU Manufacturer list, they should then select the appropriate architecture from the Specify Target Architecture drop-down.

User Manual For Cyclone LC Programmers

53

Figure 6-4: Specify Target Architecture (NXP)

Figure 6-5: Specify Target Architecture (STMicroelectronics)
Note: The user can still select an ARM-based device when using the NXP or STMicroelectronics manufacturer selections.
6.1.1.3 Device Box The Device box can be used to choose from any devices that have recently been selected.

6.1.2

Figure 6-6: Device Drop-Down - Select From Recently Chosen Devices
Security Settings - Qorivva (MPC55xx-57xx) Only
If your selected target architecture was Qorivva (MPC55xx-57xx), the Cyclone Image Creation Utility will display an area called Security Settings (see Figure 6-7). If your MPC55xx-57xx device supports uncensoring, click the "Device supports uncensoring" checkbox and select the appropriate bit depth for the device's password (64-bit or 256-bit). The box to the right is where the password must be entered. Optionally you may use the Browse button to navigate to a text file that contains the correct password for the device. The contents of the text file that you select will automatically be used to fill the password text box.

6.1.3

Figure 6-7: Security Settings - Qorivva (MPC55xx-57xx) Only
Secure Boot Settings - NXP i.MX RT Only If the selected device is an NXP i.MX RT device with secure boot capability, a Secure Boot Settings area will appear:

User Manual For Cyclone LC Programmers

54

Figure 6-8: Secure Boot Settings
The area allows the user to coordinate with PEmicro's Secure Boot Helper Utility, which is a separate utility that helps the user to more easily manage secure boot settings and configurations. Settings that the user has configured in the Secure Boot Helper Utility can be loaded into the Image Creation Utility as a resulting programming sequence.
In the Secure Boot Settings area, buttons are displayed which allow the user to do the following:
· "Link/Create Secure Boot Project" prompts the user to either choose an existing Secure Boot Project (.SBP) file or to create a new one. The Secure Boot Helper Utility will then launch and load the project.
· "Edit Secure Boot Project" prompts the user to select an .SBP project file. It will then launch the Secure Boot Helper Utility and open that project for editing.
· "Clear" removes the link to any loaded .SBP project. The user will be asked if they wish to clear the programming sequence as well.
· "Regenerate Programming Sequence From SB Settings" allows the user to load re-load the programming sequence from the .SBP project if they have made changes to the project which they wish to be reflected in the programming sequence. Note that any changes made to the programming sequence in the Image Creation Utility itself will be lost when the new sequence is loaded. This typically happens only if the device or binary has been changed in the .SBP.

Figure 6-9: Secure Boot Settings - Project Linked and Programming Sequence Loaded
When a project is linked, inputs to the Secure Boot Project such as an S19 file and PEKeyfile will be displayed next to SB File Inputs. The object to be built during image creation is also displayed below.
The user can check the checkbox for "Auto-build signed application and fuse files based on the Secure Boot Project during the SAP image creation process" if they wish that to occur during image creation.
Additional Assistance
The Secure Boot Helper Utility User Manual is available at PEmicro's website:
http://www.pemicro.com/downloads/download_file.cfm?download_id=582
The website also features a blog article that walks the user through the process of setting up a production programming image with the Secure Boot Utility and the Cyclone Image Creation Utility:
http://www.pemicro.com/blog/index.cfm?post_id=204

User Manual For Cyclone LC Programmers

55

6.1.4

Secure JTAG Settings - NXP i.MX RT Only
NXP i.MX RT devices allow the user to enable Secure JTAG. This is a security feature which allows regulation of JTAG access to the device, protected by password. Users can program a device that has Secure Boot enabled by providing the correct password. PEmicro's Secure Boot Helper Utility helps the user to manage this feature by allowing the user to create named password objects which are stored in a PE Keyfile Collection.

Figure 6-10: Secure JTAG Settings
If the user checks the box provided, the Image Creation Utility prompts the user to navigate to a PE Keyfile Collection. On the line below they will then choose the appropriate password object from that collection in order to program a device with Secure JTAG enabled.

6.1.5

Figure 6-11: Image Key Collection File and Password Object
Programming Sequence This is the two-panel interface directly below the Device Selection area. This is where the user creates the sequence of commands to be carried out during programming. The left panel provides a list of available programming functions. The right panel displays the ordering of the functions.

Figure 6-12: Specify Programming Sequence There are two ways to create the programming sequence.

6.1.5.1

Manual Selection
The user can individually specify the algorithm and the object code and then add commands. To specify the programming algorithm for the target, double-click on the Choose Algorithm (CM) function in the left panel. Or, it can be highlighted and added it to the right panel using the arrow (->). This opens the "Specify Programming Algorithm to Use" dialog.

User Manual For Cyclone LC Programmers

56

Figure 6-13: Specify Programming Algorithm To Use The user should select the programming algorithm to be used. Once the algorithm is selected, the full list of programming functions becomes available in the left panel.
Figure 6-14: Programming Functions Available Similarly, to specify the S-Record to be programmed into the target, the user may double-click on Specify Object Code (SS) in the left panel or highlight it and add it using the arrow (->). This opens a dialog which allows you to select the appropriate S-Record.

Figure 6-15: Specify Object File To Load Next, the user would add additional programming functions to complete the programming script by

User Manual For Cyclone LC Programmers

57

selecting programming operation commands from the Programming Sequence area. See Section 6.1.6 - Programming Operations for a description of these commands. The commands can added by double-clicking them, or by selecting them and using the arrow (->). Commands can also be removed or resequenced; see Section 6.1.5.3 - Function Buttons.

Figure 6-16: Add Programming Functions

6.1.5.2 Script Wizard
Another method that can be used to create a programming sequence is the Launch Script Wizard button.
Note: Launch Script Wizard removes any commands that are already in the programming sequence window and begins a new sequence.
The Launch Script Wizard button will automatically prompt the user for a programming algorithm, followed by an object file, and then adds commands (EN - Erase if not blank, PM - Program module, VC - Verify Checksum) to create a default programming script. The user can then use the programming commands on the left and function buttons to modify the programming sequence as needed.

6.1.5.3

Function Buttons
The arrow (->) will add the selected programming commands to the end of the programming sequence. Double-clicking the command has the same effect.
The Clear Script button will remove all programming commands from the right panel.
The Move Up and Move Down buttons allow the user to manually re-sequence the order of the programming commands.
The Remove From List button can be used to remove a selected command from the right panel. The user can also simply hit the Delete button on their keyboard when the command is selected in the programing sequence.

6.1.5.4

Programming Sequence Complete
Once the programming sequence is complete, the programming image can be saved to a disk or to the Cyclone unit. For more information, please see Section 6.1.12 - Store Image To Cyclone.

6.1.6

Programming Operations

Figure 6-17: Programming Operations Dialog Section

User Manual For Cyclone LC Programmers

58

The Programming Sequence field, the user may specify the algorithm, object file, and operations to be carried out.

6.1.6.1

Choose Module
Presents a list of available programming files. Each programming file contains information on how to program a particular module. Usually, the name of the file indicates what kind of module it relates to.

6.1.6.2

Specify Object File
Asks for the name (and/or path) to a file of object files to be used in programming or verifying a module. If the file is not found, an error message is given. The currently-selected file is shown in the S19 file selected window. The programmer accepts S1, S2, and S3 records. All other file records are treated as comments. If you do not specify a file-name extension .S19 is used by default. The programmer also supports ELF/Dwarf 2.0, 3.0, and 4.0 object files.
Your .S19 file may contain data for both EEPROM and flash. If you know that your S19 file contains the correct data, "Ignore S19 Range" may be checked. This will cause any out of range errors to be ignored.

6.1.6.3 Erase If Not Blank This command performs a blank check of the module and erases it if it is not blank.

6.1.6.4

Erase Module
If "Erase Module" is specified, the Cyclone will erase the EEPROM/flash on the target device after entering the Monitor Mode or BDM mode.

6.1.6.5

Blank Check Module
If "Blank Check Module" is checked, the Cyclone will check to see if the flash/EEPROM on the target device is erased.

6.1.6.6

Program Bytes
Prompts for a starting address, which must be in the module. You are then asked to enter in hexadecimal a byte to be programmed into the current location. Clicking the OK button will automatically advance to the next data byte location.

6.1.6.7

Program Words
Prompts for a starting address, which must be in the module. You are then asked to enter, in hexadecimal, a word to be programmed into the current location. Clicking the OK button will automatically advance to the next data word location.

6.1.6.8

Program Module
This command will program the selected S-record file into EEPROM/flash. For this command to work, you must have previously selected an S-record file.

6.1.6.9

Program Feature Data
The Program Feature Data option on the Cyclone Image Creation Utility gives the user more options to program dynamic data programming on the target device. To use Program Feature Data select the "PF" command when creating a programming image. A window will show you the options for feature data to program.

User Manual For Cyclone LC Programmers

59

Figure 6-18: Using PF Command (Dynamic Data)
The options can be 1) a string of the current date (YYYY-MM-DD), 2) a string of the current date and time, 24-hour clock (YYYY-MM-DD HH:MM:SS), 3) run test data. Cyclone FX only: To 4) program the barcode into the flash of the target device, BARCODESTR should be selected. The next window contains the hex address of where the dynamic data will be stored:

Figure 6-19: Program Feature Address Dialog (Hex)
6.1.6.10 Verify Module This command will verify that the selected S-record file was programmed into the EEPROM/flash. For this command to work, you must have previously selected an S-record file.
6.1.6.11 Verify Checksum This command verifies the module content via a CRC calculation. This command is typically much faster than performing a full Verify Module command.
6.1.6.12 Choose Serial File This command becomes available once a programming algorithm is selected. It specifies the serial file that holds the serial numbers to be programmed to the target.
6.1.6.13 Program Serial Number This command becomes available once a programming algorithm is selected. It will instruct the Cyclone to program the serial number to the target once executed. As with other commands, the serial number will not be programmed until the SAP operations are carried out.
6.1.6.14 User Options Commands Some ARM devices have areas of flash memory dedicated to programming user configuration data. As some writes to such areas can be sensitive or permanent, it is important that the developer is able to write these options correctly the first time and avoid mis-programming adjacent options that they wish to leave untouched. http://www.pemicro.com/blog/ index.cfm?post_id=177

User Manual For Cyclone LC Programmers

60

Figure 6-20: Program User Options Commands in Programming Sequence Panel 6.1.6.14.1 Create/Modify User Options File
When the Create/Modify User Options File (CU) command is selected it allows the developer to either: a) create a new user options (.OPT) file from scratch, or b) modify an existing .OPT file. This JSON-type file represents the user options that the developer wishes to write, and will be used by the Specify User Options File (SU) and Program User Options (PU) commands later.
Figure 6-21: CU Command Dialog a. If "Create File" is selected, a new window will open, in which the names of existing user area(s) and included options are displayed. For each user option, the developer will have the ability to either "Write [a new] Value" or "Leave [the option] Unmodified." New values must be written in hexadecimal format.

User Manual For Cyclone LC Programmers

61

Figure 6-22: Create User Options File Window
Once all new values have been written in their appropriate fields, the developer can save them to a new user options (.OPT) file.

Figure 6-23: Save User Options File Dialog b. If "Modify File" is selected, the user can choose an existing .OPT file to modify.

User Manual For Cyclone LC Programmers

62

Figure 6-24: Open User Options File Dialog The values specified in that file will be displayed in their appropriate fields.

Figure 6-25: Modify User Options File Window
At this point, the developer can choose to modify any contents of the file. The developer can either overwrite the selected file, or save the modified contents to a new filename, leaving the selected file as it was before. Once a user options (.OPT) file has been created/saved, it can be used to program the device's user options by using the Specify User Options File (SU) and Program User Options (PU) commands.
6.1.6.14.2 Specify User Options File
With the Specify User Options File (SU) command, the developer can select an existing user options (.OPT) file.

User Manual For Cyclone LC Programmers

63

6.1.7 6.1.8
6.1.9

6.1.6.14.3 Program User Options
Once a file has been specified, the Program User Options (PU) command can be used to write the values specified by the file. For most devices, new option values won't take effect until the device is reset.
Communication Mode and Rate Settings
Cyclone LC programmers support multiple communication modes and communication rates. A user needs to select proper communication mode and rate from the drop down list after programming operations are specified. The debug connector pin definitions are listed for reference.
Target Voltage and Power Settings
A user may elect to use Cyclone to supply power to the target. In this case, the Target Voltage specifies the target MCU I/O voltage level. The user needs to take into account the power discharge time for the Power Down delay. The reset driver delays, power stabilization time, and the target clock stabilization time should be considered for the Power Up delay. A checkbox is available for a user to instruct the Cyclone to turn off target power after SAP operations. If unchecked, the target power will remain on. The user has the option to provide Reset Delay if certain reset monitoring devices are used. The Cyclone will delay for the specified time after allowing the target out of reset.
Image Description
The Cyclone Image Creation Utility allows the user to summarize the purpose of their current configuration for future reference by adding text to the Image Description box. The description will be either programmed into the Cyclone or saved into an encrypted file. The image description will appear on the Cyclone's touchscreen LCD for image identification. This field will not affect the Cyclone's operations with the target. Tip: If your image will be encrypted, it can be helpful to indicate this as part of the Image Description.

Figure 6-26: Image Description Box

6.1.10

ProCryption Security Features
Cyclone FX programmers, and Cyclone LC programmers with ProCryption Security activated, can take advantage of the powerful security features that can be configured in this area of the Cyclone Image Creation Utility.

6.1.10.1 SAP Image Encryption
Users can create unique ImageKeys which can be used to encrypt their programming images. SAP images encrypted in this way can only be loaded onto a Cyclone that has been provisioned with the identical ImageKey.
Note: Both the Cyclone and the ImageKey are needed to decrypt the image. If the ImageKey is later removed from the Cyclone, the encrypted SAP image cannot be decrypted for programming. Likewise, the encrypted image cannot be read on a PC.
This section will detail how to use the Cyclone Image Creation Utility to encrypt a SAP image. For a more in-depth description of Cyclone SAP image encryption, please see CHAPTER 11 - SAP IMAGE ENCRYPTION. For detailed information about how to use and manage encrypted programming images during the production process, the user should refer specifically to Section 11.4 - Managing Encryption For Production Programming.

User Manual For Cyclone LC Programmers

64

6.1.10.1.1 Creating an ImageKey If an ImageKey has not been created or a new ImageKey is required, the user should select the "Image Encryption" combo-box in the Cyclone Image Creation Utility and choose the "Create Image Encryption Key..." option.
Figure 6-27: Create Image Encryption Key - Drop Box This will pop up a box asking for a descriptive ImageKey Name (this name will be used for display in many dialogs):
Figure 6-28: Create ImageKey After entering the name, the user should click Generate Encryption Key. This will bring up a dialog which allows the user to choose the save location:

Figure 6-29: Save Image Encryption Key To File Dialog
The user should navigate to the desired location and then click "Save". The ImageKey will be generated and automatically selected in the Cyclone Image Creation Utility, such that generating an image will use this ImageKey for encrypting.

Figure 6-30: ImageKey Selected After Creation

Note:

Every ImageKey created is unique and may not be recreated. This means that once generated, the user should keep the ImageKey in a secure place. Users may also wish to keep track of which SAP images have been encrypted with each ImageKey, as the current software does not track this information.

User Manual For Cyclone LC Programmers

65

By default, the ImageKey will stay selected in the Image Creation Utility. If a different ImageKey is required for encryption, or the user does not wish to encrypt their SAP image, the corresponding change may easily be selected using the drop-down box.
6.1.10.1.2 Encrypting A SAP Image
To create an encrypted programming image, the user sets up their parameters in the Cyclone Image Creation Utility as usual, and then simply selects the desired ImageKey in the "Image Encryption" combo-box.

Figure 6-31: ImageKey Selection
The image will automatically be generated as an encrypted image, encrypted with the selected ImageKey. An encrypted stand-alone programming image is called an eSAP (Encrypted Stand Alone Programming) file. This eSAP file may be downloaded to any Cyclone which has been provisioned with the same ImageKey (i.e. the ImageKey has already been added to the Cyclone). This is discussed in Section 11.4.1 - Provisioning a Cyclone with an ImageKey.
6.1.10.2 Image Restrictions
There are any number of reasons why the user may want to place restrictions on the use of specific programming images on a Cyclone programmer: from added ease when managing production to a desire to protect intellectual property.
Cyclone FX programmers and Cyclone LC programmers with the ProCryption Security Activation License are able to restrict the use of programming images via the associated fields in the Cyclone Image Creation Utility.

Figure 6-32: Image Restrictions
This area allows you to specify one or more restrictions and tie them to specific programming images. Even if restricted programming images are deleted from Cyclone's internal memory or an SD card, the Cyclone platform has a persistent memory that continues to tie security restrictions to that programming image. Thus, if an image is removed and re-added to a Cyclone, the image counts are maintained and would continue counting from where it left off. Also, if the SD Card is moved from Cyclone to Cyclone, the count is maintained in both Cyclones as well as the SD Card.
Every time an image is generated by the Cyclone Image Creation utility, it is encoded with a unique image ID number. All counts are stored relative to this unique ID number. So, when an image is regenerated in the Cyclone Image Creation utility, it will have its own counts which will not conflict with the previously generated image, even if the images are otherwise exactly the same. In this way, the user can regenerate an image to allow a new batch of targets to be programmed.
Note: The user may set more than one type of restriction on a programming image. The ability to program the image will be restricted by whichever triggers first. E.g., if the user creates settings to allow 100 programs, and also sets an allowed date range restriction, the ability to program the image will be restricted as soon as the first of these conditions is triggered.
Currently the user may set the following restrictions:
6.1.10.2.1 Limit Image Usage Between Dates
When "Limit Usage Between Dates" is checked and the start and end dates are specified with valid dates (format: DD/MM/YYYY), the Cyclone operator will only be allowed to program the

User Manual For Cyclone LC Programmers

66

corresponding programming image when the date is on or between the dates specified. The Cyclone has an onboard battery and clock which keeps a clock running even when power to the Cyclone is removed. This clock date is the one used for comparison to the UTD Date specified in the image. The ability to limit programming to a date is useful for making sure that an image will stop working after a period of time. This could be for security purposes, or to make sure that a new and updated image will need to be uploaded to the Cyclone after a period of time (for instance, to not allow a firmware more than a year old to be programmed onto a target).

6.1.10.2.2 Limit Number of Programs Allowed
When "Limit Number of Programs Allowed" is checked and a number is specified in the corresponding box (minimum = 1), the Cyclone operator will only be able to execute a number of successful programming operations of this programming image less than or equal to the number specified. The current programming count can be displayed on the main screen of the Cyclone or it can be seen on the image's statistics page (see Section 6.1.10.2.4 - Image Restriction Statistics).

6.1.10.2.3 Limit Number of Failures Allowed
When "Limit Number of Failures Allowed" is checked and a number is specified in the corresponding box (minimum = 1), the Cyclone operator will only be able to execute programming operations on the current image until the maximum number of errors specified has been reached. This restriction exists largely to prevent an operator from intentionally generating an error as part of the programming process in an attempt to circumvent the count restrictions. A recommended limit on this number would be on the order of 5% of the allowed programming counts.

6.1.10.2.4 Image Restriction Statistics
Statistics related to any specified restrictions for the currently selected programming image may viewed by navigating in the touchscreen menu to Current Image Operations - Show Current Image Stats. For more information on viewing programming image stats, see Section 5.2.2.4 - Show Image Restriction Stats (Requires FX or ProCryption Security Activation).
In addition, the statistics for Number of Programs & Maximum Allowed can be set to display on the home screen by navigating in the touchscreen menu to Configure Cyclone Settings -> Configure Screen -> Configure Home Screen. For more information on how to configure the Cyclone's home screen, see Section 5.2.3.5.4 - Configure Home Screen.

6.1.11

FX Exclusive Features
This area contains a hardware feature that is exclusive to the Cyclone FX, and as such cannot be licensed by Cyclone LC programmers.

6.1.12

Store Image To Cyclone
"Store Image to Cyclone" allows the current configuration to be programmed into the Cyclone. The Cyclone will then be ready for operations. After you click "Store Image To Cyclone," the Cyclone Control GUI will pop up so that you can choose the Cyclone onto which you wish to save the SAP image.

Figure 6-33: Cyclone Control GUI: Choose Cyclone for Stored Image The Cyclone Control GUI drop-down list allows the user to select from all the Cyclones available.

User Manual For Cyclone LC Programmers

67

6.1.13 6.1.14 6.1.15

In the case of a Cyclone present on a different network (i.e., not displayed automatically in the drop-down list), the user may specify its IP address by using the Specify Cyclone checkbox and typing the identifier of the Cyclone. Click on "Connect" to access the specified Cyclone. A click on the "Apply Changes" button will then store the image on the selected Cyclone.
Store Image To Disk "Store Image To Disk" allows the current configuration to be saved onto the hard drive. The image can then be transferred to the Cyclone's internal flash (or an installed SD card) via the Manage Images Utility.
Save Cyclone Configuration "Save Cyclone Configuration," in the file menu, allows the user to save the configuration into a file, which may be used for future reference, e.g., comparing the Cyclone contents with the file to see if they are the same.
Load Cyclone Configuration "Load Cyclone Configuration" in the file menu allows the user to load a configuration that has previously been saved in order to create a new image.

6.2

Managing Multiple SAP Images

The Cyclone Control GUI, shown below in Figure 6-35, allows the Cyclone to store and manage multiple images in the Cyclone's internal memory and - on a Cyclone FX or a Cyclone LC with the SDHC Port Activation License installed - on any compatible memory card that is loaded into the SDHC port (CYCLONE programmers require SDHC License Activation).

Any programming images that have been created and saved to the disk using the Cyclone Image Creation Utility may be loaded collectively onto the Cyclone, with one exception. Encrypted images may only be loaded if their ImageKey resides on the Cyclone.

User Manual For Cyclone LC Programmers

68

6.2.1 6.2.2

Figure 6-34: Manage Images Utility
Upon opening a selected Cyclone in the Cyclone Control GUI, the user is provided in the first tab with a list of the images currently on the unit's internal memory which are marked with a Storage Area label of "Internal". A list of images on any installed SDHC card will also be displayed with a Storage Area label of "External"
You can add images with the "Add Image Internal" button under the images panel. These images will appear with a "Status" label of "Ready to Store". These images are not yet in the Cyclone, the "Apply Changes" button will have to be clicked for the changes to take effect.
If the Cyclone's SDHC port is activated, the user can also add images to the external memory by using the drop-down next to the "Add Image Internal" button and selecting "External". Alternatively, once an image has been added to the proposed changes and it is in the "Ready to Store" state, the user may right click on the image and click the "Switch storage to External" option.
In Figure 6-35, note that the Encryption area displays "Encrypted" or "None" to indicate whether or not each programming image is has been encrypted. The Status area will display "Key Missing!" if the ImageKey for an encrypted image has been removed from the Cyclone.
For information on how to encrypt SAP Images and the significance of the ImageKey, please refer to Section 6.1.10.1 - SAP Image Encryption. For an overview of Cyclone SAP Image encryption and the process of using encrypted images in the production process, please see CHAPTER 11 SAP IMAGE ENCRYPTION.
Delete Images From Internal/External Memory
Any images that are already stored on the Cyclone or installed SD card can be deleted by just clicking on the trash can on the left of the image or by selecting the image and clicking the Delete key on the keyboard, the image status will be changed to "Ready to Erase." The image will be removed after "Apply Changes" is clicked.
Add/Remove Images From The Commit Changes Panels
Once the images that you wish to load appear in the images tab, you must press "Apply Changes"

User Manual For Cyclone LC Programmers

69

Note:

to update the Cyclone accordingly. No actual updates will occur to the Cyclone's internal/external memory or installed SD card until the user selects "Apply Changes.
Any SAP images that are already stored on older Cyclone models such as the Cyclone PRO, MAX, Renesas, STMicro, or Cyclone LC ARM - Rev. A/B (or on a CompactFlash card in one of those units, if applicable) can not be removed individually and can only be erased by removing all images.

User Manual For Cyclone LC Programmers

70

7 CYCLONE PROGRAMMER MANUAL CONTROL
The Cyclone LC must be configured before it can serve as a Stand-Alone Programmer. The user may manually control the Cyclone via the LCD touchscreen menu and/or the Start button, or via PC software. See CHAPTER 8 - CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE) for information on how to use the Cyclone Control Suite to configure, control, and automate Cyclone operations. The target power management schemes remain the same for each control method.

7.1
7.1.1 7.1.2
7.1.3

Operation Via Start Button

There is a Start button on the top of the Cyclone which is used for stand-alone programming. It is specified as follows.

Button

Function

START

Start executing the tasks pre-configured into the Cyclone of the currently selected programming image.

LED Indicators

The Cyclone has two (2) LEDs to indicate the current operation stage.

LED

FUNCTION

Error Success

The Cyclone failed to execute the functions as instructed. The Cyclone executed the functions successfully.

Procedure via Start Button / LEDs The following steps must be followed in order for the Cyclone to operate properly after it has been configured: 1. Turn off the target power supply if the "POWER IN" Jack is adopted. 2. Turn off the Cyclone system power. 3. Set the correct Power Management jumper settings. 4. Connect the target power supply to the "POWER IN" Jack, if applicable. 5. Connect the "POWER OUT" Jack to the target board power, if applicable. 6. Connect the ribbon cable to the target board debug connector. 7. Turn on the Cyclone system power. 8. Turn on the target power supply, if applicable. 9. Press the "START" button on the Cyclone. When the "Success" LED lights up, you have successfully programmed your target.

Example
After the user programs the contents and procedures into the Cyclone's on-board flash, the Cyclone may be used as a Stand-Alone Programmer. Suppose the user wants to perform the following instructions for a target device:
1) Erase Module 2) Program Module 3) Verify Module.
If the Cyclone is providing power to the target board, the "Target Power" icon will illuminate on the LCD display.
The Cyclone will then perform the operations. If they are performed successfully, the "Success" LED will be illuminated. One stand-alone programming cycle will have just been completed.

User Manual For Cyclone LC Programmers

71

7.2

Operation Via LCD Touchscreen Menu

Once the Cyclone LC is configured for stand-alone programming it may be operated by making selections from the touchscreen LCD menu. This section describes the menu functions that allow the user to easily execute stand-alone programming functions using the touchscreen LCD.

7.3

Home Screen

The home screen appears when the Cyclone is powered on, or when the is tapped.

Home button

7.3.1

Icons A row of icons in the upper right corner indicates the status of various attributes of the Cyclone.
Note: The user may tap on the row of icons to view the meaning of each of the currently displayed icons. Cyclone Unit Status: Ok / Bad

Programming Status: Ready / Busy

USB-To-PC Enumerated: Yes / No

Real-Time clock Enabled & Working: Yes / No

Cyclone Power Relays: Closed / Open

Target Device Is Powered*: Yes / No SDHC Memory Card: None / Valid / Unformattted / Reset Cyclone**

7.3.2

* Target Device Is Powered - "Yes" indicates that the Cyclone LC detects power on the Vcc pin of the target device programming header. ** SDHC Memory Card (Requires SDHC License Activation) - "Reset Cyclone" indicates that the Cyclone needs to be reset before the SDHC card will register as Valid. The user can push the Reset button which is located on the front side of the Cyclone, below the LED indicators.
Configurable Display Area The main area of the home screen can be configured to optionally display the following information, by using the Cyclone IP Configuration Utility (see Section 5.2.3.5.4 - Configure Home Screen): 1. Firmware version of the Cyclone (always shown). 2. IP address assigned to the Cyclone. 3. Name assigned to the Cyclone. 4. Number of programming images in the Cyclone's memory. 5. Name of the selected programming image. 6. First serial number associated with the selected image 7. Current status. 8. Results of the last operation performed. 9. Time and date. 10. Status Window and Main Menu button (always shown). 11. Programming count & limit 12.

User Manual For Cyclone LC Programmers

72

7.4
7.4.1
7.4.2

Status Window
The status window appears in the lower left corner of the home screen and displays the results of programming operations.
Error Information Icon When the Cyclone experiences an error during programming operations, the Info icon will appear to the left of the Menu button (or AUX button, if configured). Info Icon:
Press the Info icon to view a detailed description of the error.
AUX Button (Appears If Configured) The Cyclone allows the user to add an Auxiliary (AUX) button to the home screen which will perform a specific function when pressed. The specific function is chosen by the user when the AUX button is configured. The AUX button will appear on the home screen to the left of the "Menu" button, in the lower right corner of the home screen.

7.4.3

Figure 7-1: AUX Button On Home Screen (configured for perform CRC32 function) For information on how to configure the AUX button, see Section 5.2.4 - Status.
Main Menu
The Main Menu is accessible by pressing the "Menu" button when the Home Screen is displayed. The Main Menu screen contains four selections. From these, select "Current Image Options."

Figure 7-2: Touchscreen LCD Menu - Standalone Functions Highlighted

The menu selections in "Current Image Options" will allow the user to execute programming operations, verify data, toggle power, validate the programming image, and modify the upcoming serial number if necessary.

7.4.3.1

Execute Image Function
Execute Specific SAP Function presents four Stand-Alone Programming functions that you may execute by tapping the function that you wish to execute:

7.4.3.1.1 Launch Programming
This allows the user to execute the programming function. The Cyclone will program the target device, if able, using the currently selected programming image. This is functionally equivalent to

User Manual For Cyclone LC Programmers

73

pressing the Start button.

7.4.3.1.2 Verify Data In Target Performs a verify function on the data that has been programmed into the target device.

7.4.3.1.3 Toggle Power Toggles the target power and makes sure all ports are driven to debug mode level.

7.4.3.1.4 Power Cycle Device To Run User Code Toggles the target power and maintains tri-state mode for all signals.

7.4.3.1.5 Validate Image CRC32 Allows the user to perform a CRC32 validation on the currently selected programming image.

7.4.3.2

Set Image Validation
Allows the user to choose between two validation settings: 1) validate the image each time the Start button is pressed, or 2) do not validate the image.

7.4.3.3

Serial Numbers
Displays the serial number information associated with the currently selected programming image. If there is none, it will display, "This Image Contains No Serial Numbers." There may be one or more Serial Files associated with the image. The user can click on a specific Serial File name to see the following information about that Serial File:
· UID - Unique identifier of the serial number
· Next Serial # ASCII - Next serial number to be programmed (shown in ASCII format)
· Algorithm ID - Displays the algorithm ID of the serial file
· CS ID - Displays the ID of the CS (Choose Serial) command in the SAP file.

Figure 7-3: Serial File Selection
The user can also click on "Modify Serial Number" to edit that serial number. It is possible to Decrease or Increase the Next Serial by -10, -1, +1, +10. This is often done to address issues in the production process, such as during initial setup.

User Manual For Cyclone LC Programmers

74

Figure 7-4: Increase or Decrease Serial Number

Note:

The adjustment buttons will display "Increase Not Allowed" and "Decrease Not Allowed" if the image/algorithm/CS file that the user has selected does not allow for this operation.
Unlike PEmicro's current serial files, earlier "legacy" serial files are specific to one programming image, When viewing Serial Number info for an image that references one or more legacy serial files, the Cyclone will not show links to the serial files but will instead display serial number info for the first serial file. The user can then Modify Next Serial to change the next serial number, or click MORE at the bottom to proceed to the next serial file (if any).

Figure 7-5: Serial Number View With Legacy Serial Files (CS IDs #1 & #2)

7.4.3.4

Show Image Restriction Stats (Requires FX or ProCryption Security Activation)
Displays current statistics, if any, for Image Programmed Count & Maximum Allowed, Errors Logged & Maximum Allowed, and Date Range Allowed. These limits can be set in the Security Features section of the Cyclone Image Creation Utility (see Section 6.1.10.2 - Image Restrictions).
Note: When Current Image Stats is displayed as a home screen item, only Image Programmed Count & Maximum Allowed are displayed on the home screen.

User Manual For Cyclone LC Programmers

75

8 CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE)
Users who wish to control, configure, and automate one or more Cyclone units have several options available via the Cyclone Control Suite. All of these options are available to Windows users, and many are also available to macOS/Linux users.

8.1

Cyclone Control Suite - Overview

The Cyclone Control Suite is a new generation of automated control software developed to support PC-based control of Cyclone LC and Cyclone FX stand-alone programmers.

Ways to control a Cyclone include programming launch, results recovery, management of images resident on a Cyclone, addition of unique programming data for each target, as well as recovery of descriptive errors.

The Cyclone Control Suite is included with all touchscreen Cyclones. Much of the feature set works for all touchscreen Cyclones, however some advanced features require a Cyclone-resident Advanced Automation License which comes built into Cyclone FX programmers and is available as an upgrade for Cyclone LC.

8.1.1

macOS/Linux Support Notes The following information applies to operation of the Cyclone with macOS andLinux.

8.1.1.1

Minimum Required Versions The following are the minimum versions required for macOS/Linux support.
macOS: 10.13 High Sierra Linux: 18.04 LTS

8.1.1.2

Usage Differences
macOS/Linux users should note some subtle differences between using the Cyclone Control Suite with macOS/Linux vs, Windows.

8.1.1.3

Advanced Control Suite Upgrade License
macOS/Linux users should note that an Advanced Control Suite Upgrade License can be installed on the Cyclone LC, in order to enable certain advanced features (see Section 8.1.3 - Standard Features). If this license has been purchased but not yet installed, the user may need to use the Cyclone Control GUI (a Windows-only application) to connect with the Cyclone and install the license. Instructions for how to use the GUI to install the license can be found in Section 8.4.2.4 Licenses Tab.
Once this step is completed on a Windows platform, all other actions can be completed on macOS and Linux machines.Other
1. Cyclones cannot be controlled via Serial Port (RS232) using the Cyclone Control SDK or Cyclone Control Console with macOS/Linux.
2. While control and automation of existing programming images is available for Windows/ macOS/Linux platforms via the Cyclone Control Suite, the utility that is used to create and configure programming images (see Section 6.1 - Cyclone Image Creation Utility) is currently Windows only. Users should plan their projects accordingly.

8.1.1.4

Distinguishing Windows-Only And macOS/Linux-Specific Content
Information that pertains to the Windows platform only, or is particular to macOS/Linux, is indicated by the symbols below. Content can be considered to apply to all three platforms unless otherwise specified.
Windows-only:
macOS:

User Manual For Cyclone LC Programmers

76

8.1.2 8.1.3 8.1.4

Linux:

Components
The Cyclone Control Suite consists of three major components:
1. Cyclone Control SDK ­ This is a Software Development Kit with a comprehensive API allowing multiple Cyclones to be managed simultaneously from a user developed custom application that loads the provided Cyclone Control library file. The library file can be loaded from many programming languages that are able to load a such a file (C/C++, Delphi, C#, Java, Python, etc) as well as environments like LabVIEW. Examples and interface code are provided in C/C++ (MSVC and GCC), and Delphi/FPC . See Section 8.2 Cyclone Control SDK.
2. Cyclone Control Console ­ This is a powerful command-line application can be launched from a script, a command-line, or another application and allows control of one or more Cyclones simultaneously. The command-line application displays comprehensive status messages and also returns an error code which can be recovered from the calling application. See Section 8.3 - Cyclone Control Console.
3. Cyclone Control GUI ­ This is an interactive GUI based application which provides an easy way to control Cyclones and manage images resident in the Cyclones. Given its graphical nature, it is very easy to explore Cyclone Control Suite capabilities to intuitively control or interact with a Cyclone. See Section 8.4 - Cyclone Control GUI.
The Console and GUI were both built using the SDK and are good examples of the types of applications that the SDK can be used to build.
Additional sample applications come as part of the installation. They contain defined build scripts that can be used to build the sample application without any modifications.

Standard Features

The three control applications all provide the following Standard features for all Cyclones:

· Cyclone control via multiple connection types:

- USB, Serial, or Ethernet

-

: USB, Ethernet

· Select and Launch Images by Name or Enumeration

· Add/Remove/Update a single image in the Cyclone

· Add/Remove/Update multiple images in the Cyclone (GUI only)

· Recover programming result and descriptive error information

· Use automatically counting local (Cyclone stored) serial numbers

· Read/write Cyclone properties

· Read Image and target Properties and Status

·

Remote Display Access and the ability to "touch" the screen

Advanced Features

The SDK and Console applications provide the following additional Advanced features for all Cyclone FX units and any Cyclone LC upgraded with a resident Cyclone Control Advanced Automation License:

· Add/Remove/Update multiple images in the Cyclone (Console, SDK)

· Simultaneously (Gang) Control multiple Cyclones

- USB, Serial, or Ethernet

-

: USB, Ethernet

· Program (and Read) Dynamic Data in addition to fixed image data

User Manual For Cyclone LC Programmers

77

8.1.5

PEmicro Compatible Hardware The following lists the PEmicro hardware that is compatible with the Cyclone Control Suite. To ensure proper operations, PEmicro recommends upgrading all Cyclone units to the latest firmware. · Cyclone FX Universal · Cyclone FX ARM · Cyclone LC Universal · Cyclone LC ARM · Cyclone PRO (Standard features only) · Cyclone MAX (Standard features only) · Cyclone for ARM (Standard features only) · Cyclone for Renesas (Standard features only) · Cyclone for STMicro (Standard features only)

8.2

Cyclone Control SDK

The Cyclone Control SDK allows a Windows/macOS/Linux user to interact with the Cyclone via a library file (such as Windows' .dll, macOS' .dylib, or Linux' .so files).

8.2.1

Introduction
The Cyclone Control SDK is one of the three components that comprise the Cyclone Control Suite. Its library allows the user to create an application on the PC that can directly control one or more PEmicro Cyclone units. These interface routines are designed to be compiled into visual and non visual applications running on Windows, macOS, or Linux operating systems. macOS/Linux SDK files are contained in a separate .tar file (see Section 8.2.4.4 - Compiling).
The actual interface routines are located in the "cyclonecontrolsdk" library file. This library file is callable from almost any 32-bit / 64-bit Windows, macOS, or Linux development environment. Since the way the library file is called varies depending on the compiler used, PEmicro provides the library interface code and sample applications for each of the following compilers.
Note: PEmicro's blog offers articles with detailed setup instructions for some of the options below; see the accompanying links where applicable:

· Borland Delphi 2.0+ (Pascal) · GCC · MicrosoftVisual C
- Setup info: http://www.pemicro.com/blog/index.cfm?post_id=139 · Microsoft Visual C#
- Setup info: http://www.pemicro.com/blog/index.cfm?post_id=161 · NI LabVIEW 2018
- Setup info: http://www.pemicro.com/blog/index.cfm?post_id=157

8.2.2

Backwards Compatibility With Classic Cyclone Control API
The "cyclonecontrolsdk" library file is backwards compatible with many of the classic Cyclone Control API calls. In each header file, there is a constant variable or define which is declared as the file name of the library file. The value of this variable should be changed to the new filename "cyclonecontrolsdk.dll" instead of the old "cyclone_control.dll". After this modification, rebuild the project and it should continue working with the new library file.

8.2.3

Getting Started with the Cyclone Control Library File - Windows Users This section outlines the steps you need to take to begin developing your own custom application

User Manual For Cyclone LC Programmers

78

Note:

and offers tips and suggestions to get the Cyclone Control Library File working with your PEmicro hardware smoothly.
Section 8.2.1 - Introduction includes links to detailed examples for certain compilers which detail how to set up a programming image and use the SDK with some advanced options.

8.2.3.1

Example Programs
Located in the installation directory of the package, you will find two example programs that you can use as a reference for your own application. The examples are located in the following directories:
INSTALLDIR\cycloneControl\controlsdk\examples\pascal\ INSTALLDIR\cycloneControl\controlsdk\examples\c\ INSTALLDIR\cycloneControl\controlsdk\examples\labview2018 INSTALLDIR\cycloneControl\controlsdk\examples\msvc INSTALLDIR\cycloneControl\controlsdk\examples\msvcsharp These example programs are a valuable reference to use when starting your own custom application.

8.2.3.2

Starting Your Own Project
To gain access to the functions available in the library file the following files need to be added to the new project workspace:

Delphi 2.0+ Projects
U

INSTALLDIR\cycloneControl\controlsdk\examples\pascal\cyclone_control_api.pas

All other source files which will call functions from the library file should include the above file using the Delphi "uses" command.

MSVC 5.0+ Projects
U

INSTALLDIR\cycloneControl\controlsdk\examples\c\cyclone_control_api.h INSTALLDIR\cycloneControl\controlsdk\examples\c\cyclone_control_api.c

All other source files which will call functions from the library file should include the above header file with the C/C++ #include directive.

MSVC# 2017 Projects

INSTALLDIR\cycloneControl\controlsdk\examples\msvcsharp\visual_sap_control\cyclone_control _api.cs

NI LabVIEW 2018 Projects

INSTALLDIR\cyclone\cycloneControl\controlsdk\examples\labview2018\user.lib\cyclonecontrolsdk \cyclonecontrolsdk.lvlib
INSTALLDIR\cyclone\cycloneControl\controlsdk\examples\labview2018\user.lib\cyclonecontrolsdk \VIs\*.vi

User Manual For Cyclone LC Programmers

79

The pre-built VIs that we provide include modifications for error handling using error clusters. Please visit our blog post "Automated Flash Programming with LabVIEW" for more information on how to develop your own LabVIEW project.

8.2.4

Getting Started with the Cyclone Control Library File - macOS/Linux Users
This section outlines the steps needed to begin developing a custom application and offers tips and suggestions to get the Cyclone Control SDK library working smoothly with PEmicro hardware.

8.2.4.1

SDK Contents
macOS/Linux users will require the CycloneControlSDK.tar file, an archived (zipped) file which includes macOS and Linux releases. The release is structured along the following directories:
· Linux: C and C++ example files, the "cyclonecontrolconsole" command line utility, CycloneControlGUI, and the "libcyclonecontrolsdk.so" library
· macOS: C and C++ example files, the "cyclonecontrolconsole" command line utility, CycloneControlGUI, and the "libcyclonecontrolsdk.dylib" library
· Firmware: The latest firmware releases
· User manuals: The user manual for the Cyclone programmer.

8.2.4.2

Example Programs
Located in the macOS and Linux directories of the package, you will find two example programs that you can use as a reference for your own application. The examples are located in the following directories:
INSTALLDIR/macOS/c: C example files for macOS INSTALLDIR/macOS/cpp: C++ example files for macOS INSTALLDIR/linux/c: C example files for Linux INSTALLDIR/linux/cpp: C example files for Linux These example programs are a valuable reference to use when starting your own custom application.

8.2.4.3

Starting Your Own Project
The Cyclone Control Console (cyclonecontrolconsole) comes ready to use. To use it, you can simply invoke a commandline command such as:
./cyclonecontrolconsole -cyclone=usb1 -listimages
./cyclonecontrolconsole -cyclone=10.1.2.3 -launchimage=1
The first command will query a Cyclone unit connected via a USB cable and list any programming images that are on board. The second command will remotely launch the first programming image that is on a Cyclone with IP number 10.1.2.3.
For a full description please see Section 8.3 - Cyclone Control Console.

8.2.4.4

Compiling
In order to compile (or use the Makefile), you will need to have the appropriate compiler (such as gcc or g++) available. These compilers are often native to Linux. Mac users will need to have Xcode and its command-line utilities installed.

8.2.4.4.1 How To Build
The examples show how you can write a custom application using the SDK library. To build the example files, change directory into the appropriate folder (such as "cd example\cpp") and invoke the Makefile by calling "make" from a command line.

User Manual For Cyclone LC Programmers

80

8.2.5

Please note that the Makefile only builds the example file, it does not copy the files necessary to immediately use the compiled program. To do that, please perform a "make install", this will copy the appropriate firmware files as well as the libcyclonecontrolsdk library, into a "deploy" folder, thereby making the custom program readily usable. Once you have peformed "make" and "make install", you can cd into the deploy directory and invoke the program as follows:
./apiExample -cyclone=usb1 -listimages This will show the programming images that are on a Cyclone connected through a USB cable.
8.2.4.4.2 Running An Application On macOS
By default, MacOS does not allow applications from unindentified developers to run on the system. This would cause a message stating that the application "cannot be opened because the developer cannot be verified." There are two ways to resolve this issue:
1. You can simply navigate to the file on an explorer, right click on the executable, and select the "Open with" option to open the application with Terminal.app. You will then be albe to open the application.
2. You can completely disable this feature through the System Preferences menu, although it is not a recommended option.
Initialization
Loading the DLL (C/C++ Projects only)
U

Before calling any routines from the DLL, the DLL must be loaded into memory. To do this, the following function has been provided in the included header files. Refer to Chapter 4 of this manual for a detailed description of this function.

loadLibrary( );

For Delphi (Pascal) and C# users, this process is transparent for the user and no action is required.

Enumerate all ports
U
After loading the DLL, a call to the following function is required in order to properly initialize all devices. This function should only be called once, typically at the beginning of the application.

enumerateAllPorts( );

Connect to the PEmicro hardware interface
U
The next step is to establish communications with the PEmicro Cyclone unit. This is accomplished with the following function call:

connectToCyclone( );

Refer to Chapter 4 of this manual for a detailed description of this function. This call returns the handle to the Cyclone unit which is used in all other routines in the DLL to identify the Cyclone. Note that the special case of a return value of 0 indicates an error contacting the Cyclone. This function will be called once for each Cyclone.

User Manual For Cyclone LC Programmers

81

8.2.6

Finalization
Before closing the application, it is recommended that the session with the PEmicro hardware be terminated and the DLL unloaded from memory.

These calls should always be made before the application closes:

disconnectFromAllCyclones( ); unloadLibrary();

Note that the "unloadLibrary" call is only required for C/C++ applications. For the Delphi and C# example projects, the DLL is automatically unloaded when the application closes.

8.2.7

Initial Cyclone Setup
The Cyclone Image Creation Utility software, which is included with each Cyclone, is used to create the standalone images that will be stored in the non-volatile memory of the Cyclone.
Note: Mac/Linux users will need a Windows platform for the image creation and configuration process.

These programming images contain the FLASH / EEPROM programming algorithms, the actual binary data to be programmed, the sequence of programming operations, and user specified Cyclone settings.
Prior to using the Cyclone Control Suite, these standalone images need to be created. Please refer to the user's manual of your Cyclone unit for more information on standalone images and image creation.

8.2.8

Typical Usage

Figure 8-1: Typical programming procedure flow chart
Figure 8-1 describes the most common sequence of calls to the DLL after successfully connecting to the Cyclone unit.
a. Initiate programming operations. "startImageExecution" carries out the programming operations defined in the stand-alone image stored on the Cyclone unit.

User Manual For Cyclone LC Programmers

82

8.2.9 8.2.10

b. Wait for programming completion. Note that no error checking is provided by the "checkCycloneExecutionStatus" call. A result of 0 will be returned even if an error has occurred or if communication with the Cyclone is lost.
c. Retrieve the error code from the Cyclone unit to determine if the programming was successful.
External Memory Storage Support
Some Cyclones support external memory storage. The Cyclone Control SDK and Cyclone Control Console both support images residing on external memory cards. The parameter "selectedMediaType" is used to select between Cyclone internal Flash and external memory.
Image numbers will go in ascending order starting with image number 1. Internal images will be counted first and external image numbers will start after the last internal image number. Image number 1 will refer to the first image in the internal memory if there are any images in the Cyclone internal memory, if there are no internal images, image 1 will refer to the first image in the external memory.
Modifying images residing in external memory will only be available on Cyclones with the proper license. Certain Cyclones may require a supplementary license to support external memory.
Application Programming Interface (API)
This chapter describes the API of the "CycloneControlSDK.dll" in detail. A C/C++ function prototype is given here. Header files are provided for the following languages:

Pascal C/C++
8.2.10.1 Constants

Name CyclonePortType_USB CyclonePortType_Ethernet CyclonePortType_Serial

32-bit Value 5 6 7

CycloneInformation_IP_Address

1

CycloneInformation_Name

2

CycloneInformation_Generic_Port_Number

3

CycloneInformation_Cyclone_Type_String

4

MEDIA_INTERNAL

1

MEDIA_EXTERNAL

2

8.2.10.2 DLL Loading / Unloading Calls 8.2.10.2.1 loadLibrary
bool loadLibrary(char *filepath);

User Manual For Cyclone LC Programmers

83

This function loads the CycloneControlSDK.dll into memory and gives the user access to all of the functions available in the library. This routine must be called before any of the other routines can be called.

@returnvalue
8.2.10.2.2 unloadLibrary
void unloadLibrary(void);

True if the load was successful, false otherwise.

This function unloads the DLL loaded with loadLibrary( ). This call should be made before the application starts to unload itself.
8.2.10.2.3 enumerateAllPorts
void enumerateAllPorts(void);

This function performs all necessary initialization in order to successfully communicate with a Cyclone. The function is called once before the first call to "connectToCyclone".
8.2.10.2.4 disconnectFromAllCyclones
void disconnectFromAllCyclones(void);

This function closes all open Cyclones (if any) and frees all dynamic memory used by the DLL. The function is called before the user application is closed.
8.2.10.2.5 version
char *version(void);

This call returns a pointer to a null-terminated string that contains the version number of the DLL.

@returnvalue A pointer to a null-terminated string containing the version number of the DLL. 8.2.10.2.6 queryNumberOfAutodetectedCyclones
uint32_t *queryNumberOfAutodetectedCyclones(void);
This function returns the number of Cyclones connected locally on USB and on your local network.

@returnvalue

The number of Cyclones.

8.2.10.2.7 queryInformationOfAutodetectedCyclone
char *queryInformationOfAutodetectedCyclone(int32_t autodetectIndex, int32_t informationType);

@parameter autodetectIndex

Specifies the index of the detected Cyclone by the function queryNumberOfAutodetectedCyclones(). The valid range for this parameter is from 1 to the number of Cyclones detected.

User Manual For Cyclone LC Programmers

84

@parameter informationType
@returnvalue

Specifies the property of the Cyclone to return. The possible values are: · CycloneInformationation_IP_Address · CycloneInformation_Name · CycloneInformation_Generic_port_number
A pointer to a null-terminated string containing the property value of the specified Cyclone.

8.2.10.3 Cyclone Connecting / Disconnecting Calls

8.2.10.3.1 connectToCyclone
uint32_t connectToCyclone(char *nameIpOrPortIdentifier) ;

This function opens a session with a Cyclone and tests the connection. The handle returned by this function is passed as a parameter to other functions provided by the DLL. If you connect to a Cyclone that already has a handle, the same handle is returned. If there is a failure contacting the Cyclone, the function returns a 0.
Note that the DLL does not support multiple Cyclones connected via the serial port. If you require more than one Cyclone to use a serial port connection, PEmicro recommends using the RS232 communication protocols.

A pointer to a null-terminated string which uniquely identifies the Cyclone connected to the host PC.

If identifying by IP address, the string should be in the format of xxx.xxx.xxx.xxx, where xxx = 0...255.

@parameter nameIPOrPortIdentifier

If identifying by name, the string should contain the name of the Cyclone.
If identifying by port and the Cyclone is connected by USB, the string should be USB# where # is 1...8. If the Cyclone is connected by Ethernet, the string should be in the format of xxx.xxx.xxx.xxx, where xxx = 0...255.

@returnvalue

If the Cyclone is connected by Serial, the string should be COM1.
The handle to the opened Cyclone unit. A return value of 0 indicates a failure to connect to the specified Cyclone unit.

8.2.10.3.2 connectToMultipleCyclones
bool connectToMultipleCyclones(char *nameIpOrPortIdentifierArray, multipleCycloneHandleArrayPtrType cycloneHandleArrayPointer, int32_t *numberOfCycloneOpensAttempted);

This function returns a array of handles to opened Cyclones from a null-terminated String of comma delimited identifiers.

User Manual For Cyclone LC Programmers

85

A null terminated string containing one or more Cyclone identifiers (name, IP address, or port number) delimited by commas.

Example: USB1,209.1.10.2,Orion,COM1

@parameter nameIpOrPortIdentifierArray

If identifying by IP address, the string should be in the format of xxx.xxx.xxx.xxx, where xxx = 0...255.

If identifying by port and the Cyclone is connected by USB, the string should be USB# where # is 1...8.

@parameter multipleCycloneHandleArrayPtrType
@parameter numberOfCycloneOpensAttempted
@returnvalue

If the Cyclone is connected by Serial, the string should be COM1.
A pointer to an array of Cyclone handles. Each element of the array corresponds to the position of the identifier in the previous parameter. If the function connected to the Cyclone, the value of the array element would correspond to its handle otherwise it will be 0.
This value will be modified with the number of Cyclones that the function attempted to open. It is also the size of the multipleCycloneHandleArrayPtrType structure.
True if every Cyclone was identified and has a valid handle.
False if there were any errors identifying or connecting to any of the Cyclones.

8.2.10.3.3 setLocalMachineIpNumber
void setLocalMachineIpNumber(char* ipNumber);

If a PC has multiple network interface cards, this function sets the IP address of the network card to use communicate with the Cyclones. This is called prior to calling any other functions.

@parameter ipNumber

A pointer to a null-terminated character string in the format xxx.xxx.xxx.xxx, where xxx = 0...255, representing the IP address of the network card.

8.2.10.4 Controlling Cyclone Programming 8.2.10.4.1 startImageExecution
bool startImageExecution(uint32_t cycloneHandle, uint32_t imageId);

User Manual For Cyclone LC Programmers

86

A Cyclone may have several independent programming images in its non-volatile internal or external memory. A programming image contains the programming algorithms, binary data, and programming sequence. This function instructs the Cyclone to start execution of an image. After invoking this call, the "checkCycloneExecutionStatus" function is used to poll the Cyclone until completion.

@parameter cycloneHandle The handle of the Cyclone to begin programming operations

@parameter imageId

Selects the image on the Cyclone to use. The valid range of this parameter is from 1 to the total number of images in the Cyclone with the count starting from internal memory and then external memory.

@returnvalue

If a Cyclone only stores one image, this parameter is 1. True if the programming process has started successfully.
False otherwise.

8.2.10.4.2 startDynamicDataProgram
bool startDynamicDataProgram(uint32_t cycloneHandle, uint32_t targetAddress, uint16_t dataLength, char *buffer);

Sometimes, in addition to the large amount of static data being programmed into a target from the Cyclone, it is advantageous for the calling application to program small sections of unique data dynamically. Examples of this include date/time, serial number, MAC addresses, and lot numbers.

This function is valid to be called only after a programming image has been programmed into the target (once startImageExecution has completed). Call the "checkCycloneExecutionStatus" function to wait for completion. If the target is reset by the Cyclone or by a power cycle after programming the image, this function will fail. The workaround for this is to execute a second image that will re-load the algorithm before you call startDynamicDataProgram.

@parameter cycloneHandle @parameter targetAddress @parameter dataLength @parameter buffer
@returnvalue

The handle of the Cyclone to begin dynamic programming. The first memory address of the target processor where the dynamic data should be written. The total number of bytes to be written. This parameter cannot be greater than 255. A pointer to the array which holds the data to be written. True if the programming process has started successfully.
False otherwise.

8.2.10.4.3 checkCycloneExecutionStatus
uint32_t checkCycloneExecutionStatus(uint32_t cycloneHandle);

User Manual For Cyclone LC Programmers

87

Checks to see if the Cyclone has completed a programming operation started with either the "startImageExecution" or "startDynamicDataProgram" functions.
After this function returns with completed value, "getLastErrorCode" should be called to determine the programming result. A result of 0 will be returned even if a programming error has occurred or if communication with the Cyclone is lost.

@parameter cycloneHandle @returnvalue

The handle of the Cyclone to perform a status check on. 1 = Currently programming 0 = Completed (with or without error)

8.2.10.4.4 dynamicReadBytes
bool dynamicReadBytes(uint32_t cycloneHandle, uint32_t targetAddress, uint16_t dataLength, char *buffer);

This function reads a specified number of bytes from a specified memory address of the target processor. This call is only valid after first having made a call to the "startImageExecution" function in the sequence of commands.

@parameter cycloneHandle @parameter targetAddress @parameter dataLength @parameter buffer
@returnvalue

The handle of the Cyclone that will perform the dynamic read.
The first memory address of the target processor where the data will be read.
The number of total bytes to read from the target processor
A pointer to the array where the data read will be stored. This array must have been allocated prior to calling this function.
True if the data was successfully read False otherwise

8.2.10.4.5 getNumberOfErrors
uint32_t getNumberOfErrors(uint32_t cycloneHandle);
This function returns a count of all the errors recorded in the DLL and in the Cyclone.

@parameter cycloneHandle @returnvalue

The handle of the Cyclone to get a count of the errors. The number of errors in the DLL and in the Cyclone.

8.2.10.4.6 getErrorCode
int32_t getErrorCode(uint32_t cycloneHandle, uint32_t errorNum);

This function returns the error code of the specified error number recorded in the DLL or in the Cyclone. It should be called when the function getNumberOfErrors() is greater than or equal to 1.

@parameter cycloneHandle @parameter errorNum

The handle of the Cyclone to retrieve the error code.
This specifies the error number. The valid range for this parameter is from 1 to the total number of errors.

User Manual For Cyclone LC Programmers

88

@returnvalue

The error code of the DLL or Cyclone

8.2.10.4.7 getLastErrorAddr
uint32_t getLastErrorAddr(uint32_t cycloneHandle);

If the "getErrorCode" function returns a non-zero value (indicating an error has occurred), this routine can be used to query the address where the error occurred.

@parameter cycloneHandle @returnvalue

The handle of the Cyclone from which to request the error address.
The memory address where the last programming error occurred.

8.2.10.4.8 getDescriptionOfErrorCode
char *getDescriptionOfErrorCode(uint32_t cycloneHandle, int32_t errorCode);

This function returns a description of the error code.

@parameter cycloneHandle The handle of the Cyclone to retrieve the error code description.

@parameter errorCode

The error code to check.

@returnvalue

A pointer to a null-terminated character string that contains the error code description.

8.2.10.4.9 resetCyclone
bool resetCyclone(uint32_t cycloneHandle, uint32_t resetDelayInMs);

This function performs a hard reset of the Cyclone. It is the same as pressing the reset button. This is considered a legacy call and does not need to be called by the application.

@parameter cycloneHandle @parameter resetDelayInMs @returnvalue

The handle of the Cyclone that will be reset.
The reset delay, specified in milliseconds. The delay should be at least 5500 ms.
True if reset was successful False otherwise

8.2.10.5 Configuration / Image Maintenance Calls 8.2.10.5.1 getImageDescription
char *getImageDescription(uint32_t cycloneHandle, uint32_t imageId) ;

This function returns the description of a particular image stored on the Cyclone (internal Flash or external memory card). This description is specified by the user when the image is created.

@parameter cycloneHandle

The handle of the Cyclone to get an image description.

User Manual For Cyclone LC Programmers

89

@parameter imageId

Used to select which image stored on the Cyclone to read the description from. The valid range of this parameter is from 1 to the total number of images in the Cyclone with the count starting from internal memory and then external memory.

@returnvalue

If a Cyclone only stores one image, this parameter should be set to 1.
A pointer to a null-terminated character string which contains the image description

8.2.10.5.2 formatCycloneMemorySpace
bool formatCycloneMemorySpace(uint32_t cycloneHandle, uint32_t selectedMediaType);

This function erases all images stored on the selected media type.

@parameter cycloneHandle @parameter selectedMediaType @returnvalue

The handle of the Cyclone that will have its images erased
This parameter selects between Cyclone internal Flash (selectedMediaType = 1) or external memory (selectedMediaType =2).
True if the erasure was successful False otherwise

8.2.10.5.3 eraseCycloneImage
bool eraseCycloneImage(uint32_t cycloneHandle, uint32_t imageId);

This function erases the specified image that is stored on the Cyclone. This function is not supported by legacy Cyclones.

@parameter cycloneHandle The handle of the Cyclone that will have its image erased

@parameter imageId

Selects the image on the Cyclone to use. The valid range of this parameter is from 1 to the total number of images in the Cyclone with the count starting from internal memory and then external memory.

@returnvalue

If a Cyclone only stores one image, this parameter is 1. True if the erasure was successful False otherwise

8.2.10.5.4 addCycloneImage
uint32_t addCycloneImage(uint32_t cycloneHandle, uint32_t selectedMediaType, bool replaceImageOfSameDescription, char *aFile);

This function adds a specified stand-alone programming image into the selected media type. The

User Manual For Cyclone LC Programmers

90

image files have a .SAP file extension and are created with the Cyclone Image Creation Utility. If the Cyclone's storage limits are reached, this routine will return an error.

@parameter cycloneHandle @parameter selectedMediaType @parameter replaceImageOfSameDescription @parameter aFile
@returnvalue

The handle of the Cyclone that will accept the new image
This parameter selects between Cyclone internal Flash (selectedMediaType = 1) or external memory (selectedMediaType =2).
Set to True if you want the image to overwrite any existing images with the same description
Set to False if you do not want the image to overwrite any existing images with the same description. An error will occur.
A pointer to a null-terminated character string which contains the full path to the .SAP file to be added.
The image number of the image that was just added. This number is used as the "imageId" parameter for some function calls.

A return value of "0" indicates an error has occurred during the process.

8.2.10.5.5 countCycloneImages
uint32_t countCycloneImages(uint32_t cycloneHandle);

This function returns the number of stand-alone programming images currently stored in the internal Flash and the external memory card of the Cyclone.

@parameter cycloneHandle @returnvalue

The handle of the Cyclone to query for the image count
The total number of images stored in internal and external memory.

8.2.10.5.6 getPropertyValue
char *getPropertyValue(uint32_t cycloneHandle, uint32_t resourceOrImageId, char *categoryName, char *propertyName);

This function reads a property value of the Cyclone or a stored SAP image. Examples of properties are Cyclone Name, Cyclone IP Address, Image Name or Image media type. There are different categories with different properties. Refer to the header file for a list of valid category and property names. The function getPropertyList will return a list of valid properties for each category.

@parameter cycloneHandle @parameter resourceOrImageId

The handle of the Cyclone from which to read the property.
The id for image properties is the image id on the Cyclone. The id for Cyclone or Network properties is 0.

User Manual For Cyclone LC Programmers

91

@parameter categoryName @parameter propertyName @returnvalue

A pointer to a null-terminated character string that contains the category of the property that will be read.
A pointer to a null-terminated character string that contains the name of the property that will be read.
A pointer to a null-terminated character string that contains the value of the property.

8.2.10.5.7 setPropertyValue
bool setPropertyValue(uint32_t cycloneHandle, uint32_t resourceOrImageId, char * categoryName, char *propertyName, char * newValue);

This function changes the property of the Cyclone to the value specified. Only certain properties can be changed using this call. This function will return false if the property was not changed. Refer to the header file for a list of valid category and property names. The function getPropertyList will return a list of valid properties for each category.

@parameter cycloneHandle

The handle of the Cyclone from which to read the property.

@parameter resourceOrImageId

The id for image properties is the image id on the Cyclone. The id for Cyclone or Network properties is 0.

@parameter categoryName

A pointer to a null-terminated character string that contains the category of the property that will be modified.

@parameter propertyName

A pointer to a null-terminated character string that contains the name of the property that will be modified.

@parameter newValue

A pointer to a null-terminated character string that contains the new value of the property.

@returnvalue

True if the data was successfully set False otherwise

8.2.10.5.8 getPropertyList
char *getPropertyList(uint32_t cycloneHandle, uint32_t resourceOrImageId, char *categoryName);

This function returns a list of valid category and property names that can be used with the "getPropertyValue" and "setPropertyValue" functions. Refer to the header file for a list of valid category and property names.

@parameter cycloneHandle @parameter resourceOrImageId @parameter categoryName @returnvalue

The handle of the Cyclone that will return the property list.
The id for image properties is the image id on the Cyclone. The id for Cyclone or Network properties is 0.
A pointer to a null-terminated character string that contains the category of the property list.
A pointer to a null-terminated character string that contains a list of property names.

User Manual For Cyclone LC Programmers

92

8.2.10.6 Features Calls 8.2.10.6.1 getFirmwareVersion
char *getFirmwareVersion(uint32_t cycloneHandle);
This function reads the firmware version of the selected Cyclone.

@parameter cycloneHandle The handle of the Cyclone of which to read the firmware version.

@returnvalue

Returns a pointer to a null-terminated character string containing the firmware version.

8.2.10.6.2 cycloneSpecialFeatures
bool cycloneSpecialFeatures(uint32_t featureNum, bool setFeature, uint32_t paramValue1, uint32_t paramValue2, uint32_t paramValue3, void *paramReference1, void *paramReference2);

This function is used for executing special features described by the featureNum parameter. Refer to the parameter specifications below for details.

@parameter featureNum

CYCLONE_GET_IMAGE_DESCRIPTION_FROM_FILE

@parameter setFeature

Indicates whether the image file has been decoded. If previous operations has already decoded the file, then set it to true. Otherwise set it to false.

@parameter paramValue1

Ignored, set it to 0.

@parameter paramValue2

Ignored, set it to 0.

@parameter paramValue3

Ignored, set it to 0.

A pointer to a pointer to a null-terminated character @parameter paramReference1 string that contains the image description of the SAP
file.

@parameter paramReference2

A pointer to a null-terminated character string which contains the full path to the specified SAP file.

@returnvalue

True if the image description was read False otherwise

@parameter featureNum @parameter setFeature @parameter paramValue1 @parameter paramValue2
User Manual For Cyclone LC Programmers

CYCLONE_GET_IMAGE_CRC32_FROM_FILE Indicates whether the image file has been decoded. If previous operations has already decoded the file, then set it to true. Otherwise set it to false. Ignored, set it to 0. Ignored, set it to 0.
93

@parameter paramValue3

Ignored, set it to 0.

@parameter paramReference1

A pointer to an unsigned 32-bit value containing the CRC32 of the SAP file.

@parameter paramReference2

A pointer to a null-terminated character string which contains the full path to the specified SAP file.

@returnvalue

True if the CRC32 was read False otherwise

@parameter featureNum

CYCLONE_GET_IMAGE_SETTINGS_FROM_FILE

@parameter setFeature

Indicates whether the image file has been decoded. If previous operations has already decoded the file, then set it to true. Otherwise set it to false.

@parameter paramValue1

The type of setting to extract {configuration script=1, image unique id etc.=2, serial numbers=3, additional settings=4, crc_exclusive settings=5}.

@parameter paramValue2

Ignored, set it to 0.

@parameter paramValue3

Ignored, set it to 0.

@parameter paramReference1

A pointer to a pointer to a null-terminated character string that contains the settings of the SAP file.

@parameter paramReference2

A pointer to a null-terminated character string which contains the full path to the specified SAP file.

@returnvalue

True if the image settings was read False otherwise

@parameter featureNum

CYCLONE_GET_IMAGE_COMMMAND_LINE_PAR AMS_FROM_FILE

@parameter setFeature

Indicates whether the image file has been decoded. If previous operations has already decoded the file, then set it to true. Otherwise set it to false.

@parameter paramValue1

Ignored, set it to 0.

@parameter paramValue2

Ignored, set it to 0.

@parameter paramValue3

Ignored, set it to 0.

A pointer to a pointer to a null-terminated character @parameter paramReference1 string that contains the command line parameters of
the SAP file.

User Manual For Cyclone LC Programmers

94

@parameter paramReference2

A pointer to a null-terminated character string which contains the full path to the specified SAP file.

@returnvalue

True if the command line parameters was read False otherwise

@parameter featureNum

CYCLONE_GET_IMAGE_SCRIPT_FILE_FROM_FI LE

@parameter setFeature

Indicates whether the image file has been decoded. If previous operations has already decoded the file, then set it to true. Otherwise set it to false.

@parameter paramValue1

Ignored, set it to 0.

@parameter paramValue2

Ignored, set it to 0.

@parameter paramValue3

Ignored, set it to 0.

@parameter paramReference1

A pointer to a null-terminated character string that contains the name of the script file.

@parameter paramReference2

A pointer to a null-terminated character string which contains the full path to the specified SAP file.

@returnvalue

True if the script file was read False otherwise

@parameter featureNum CYCLONE_TOGGLE_POWER_NO_DEBUG

@parameter setFeature

Ignored, set it to false.

@parameter paramValue1

Ignored, set it to 0.

@parameter paramValue2

Ignored, set it to 0.

@parameter paramValue3

Ignored, set it to 0.

@parameter paramReference1

Ignored, set it to null.

@parameter paramReference2

Ignored, set it to null.

@returnvalue

True if the power was toggled. False otherwise

@parameter featureNum
User Manual For Cyclone LC Programmers

CYCLONE_SET_ACTIVE_SECURITY_CODE
95

@parameter setFeature

Ignored, set it to true.

@parameter paramValue1

The security code type (e.g. MON08, Renesas, PPC Nexus 64 bit, PPC Nexus 256 bit ignored, set it to 0).

@parameter paramValue2

The length of the security code bytes.

@parameter paramValue3

Ignored, set it to 0.

@parameter paramReference1

A pointer to an array containing the security code bytes.

A pointer to a null-terminated character string @parameter paramReference2 containing the security type string (such as 'MON08',
'RENESAS', 'PPCNEXUS').

@returnvalue

True if the security code was set False otherwise

8.3
8.3.1 8.3.2

Cyclone Control Console
The Cyclone Control Console, the next component of the Cyclone Control Suite, is an application that controls Cyclone operations through the use of simple console commands. This application is very easy for Windows/macOS/Linux users to set up and use and offers functionality very similar to using the Cyclone Control library file directly.
To find the Cyclone Control Console application, navigate to the following directory:
[INSTALLDIR]\Cyclone Control\
The Cyclone Control software performs all operations specified in simple commands. A separate batch file would typically be used to launch the utility with the correct parameters.

Startup

a. Connect all Cyclone units to the PC via RS232 , USB, or Ethernet. Any combination of different connections is allowed. The exception is that only one RS232 serial port connection can be used; no more than one Cyclone can be connected via the RS232 serial port.
b. Connect all Cyclones to their target systems. This is done using a ribbon cable that connects from the Cyclone to a debug header on the target board.
c. Power up the PC, all Cyclone units, and all target systems that require external power.
d. Run the CycloneControlConsole software from the command prompt.

Command-Line Parameters The command-line utility supports the following commands:

-listcyclones
Shows a list of auto-detected Cyclones

-cyclone=[cyclone identifier]
Opens the Cyclone or Cyclones by name or identifier. The Cyclone argument can be a single identifier or a comma delimited list. Available identifiers are cyclone name, port number, or IP address.

User Manual For Cyclone LC Programmers

96

-listimages
List the images present on all open Cyclones. If there are no open Cyclones the command will list the images on all detected Cyclones.
-launchimage=[image name or number]
Launch a specific image on the open Cyclones. The image can be identified by name or image number.
-putdynamicdata=[cyclone number],[address],[data]
ONLY SUPPORTED BY CYCLONE FX OR THE CYCLONE CONTROL SUITE ADVANCED LICENSE. Performs programming of dynamic data with the selected Cyclone unit. [cyclone number] is the index of the connected Cyclone in the order in which it was entered. [address] is the starting memory address. [data] are the bytes of data to be programmed. All values should be in hexadecimal format. No more than 255 bytes may be programmed this way.
A Cyclone unit may only use this command after it has performed its "-launchimage" command.
If the target is reset after programming the image, "-putdynamicdata" will fail. The workaround to this is to execute a second blank image that will re-load the algorithm before using this command.
-putdynamicstring=[cyclone number],[address],[string]
Performs programming of dynamic data with the selected Cyclone unit. [cyclone number] is the index of the connected Cyclone in the order in which it was entered. [address] is the starting memory address. [string] is the data in string format. No more than 255 bytes may be programmed this way.
A Cyclone unit may only use this command after it has performed its "-launchimage" command.
If the target is reset after programming the image, "-putdynamicstring" will fail. The workaround to this is to execute a second blank image that will re-load the algorithm before using this command.
-showproperties=[category],[image id if applicable]
List all available properties in a [category] in the open Cyclones or a stored SAP image by using the [image id if applicable] argument. Refer to the header file for a list of valid category and property names. Using an empty string as the [category] value will return the available categories.
-addimageinternal=[filename]
Add a specific programming image to the internal memory of the open Cyclones. [filename] is the path and filename of the image to be programmed into the Cyclones.
-addimageexternal=[filename]
ONLY SUPPORTED WITH CYCLONE FX OR THE CYCLONE MEMORY EXPANSION LICENSE. Add a specific programming image to the external memory of the open Cyclones. [filename] is the path and filename of the image to be programmed into the Cyclones.

User Manual For Cyclone LC Programmers

97

-eraseallinternalimages
Preform a format of the internal memory connected to the open Cyclones. This will cause all internal images to be erased.
-eraseallexternalimages
Preform a format of the external memory connected to the open Cyclones. This will cause all external images to be erased.
-eraseimage=[image name or number]
Erase an individual image from the open Cyclones. The image can be identified by image name or by image number.
-listserialfiles
List Serial Files in Cyclone
-addserialfile=[file path]
Add Serial File to Cyclone
-deleteserialfile=[object ID or display index]
Delete Serial File from Cyclone. Can be deleted by ID or by display index.
-firmwareupdate=[firmware update mode]
Set the firmware update mode to "auto", "dontupdate", "forceupdate". The default mode is "auto."
-help
Display a list of available commands.

The following command-line parameters require a Cyclone FX, or a Cyclone LC with the ProCryption Security Activation License.

-listencryptionkeys
List Encryption Key Files that reside on Cyclone

-addencryptionkey=[file path]
Securely add ImageKey file to Cyclone (encrypted with Cyclone-specific RSA public key). The file path is the path to the ImageKey.

-deleteencryptionkey=[object ID or display index]
Delete ImageKey File from Cyclone. Can be deleted by ID, or by display index number (listencryptionkeys returns a numbered list of ImageKeys; the display index corresponds to these

User Manual For Cyclone LC Programmers

98

numbers).

8.3.3

Examples
This section provides some basic examples that demonstrate how to use the Cyclone Control Console to connect to the Cyclone, manage programming images, launch programming, etc.

Note: A more expansive list of examples is available on our website at: http://www.pemicro.com/blog/index.cfm?post_id=142

The commands should be separated by a space. Every command starts with a "-" character, arguments follow the "=" character.

8.3.3.1 Typical Usage

CycloneControlConsole.exe ­cyclone=10.0.1.1 ­launchimage=1

This example connects to a single Cyclone identified by its IP address 10.0.1.1 and executes its first image. This is the most common usage of the Cyclone Control Utility.
CycloneControlConsole.exe ­cyclone=USB1 ­launchimage=1

This example connects to a single Cyclone enumerated on USB1 and executes its first image. 8.3.3.2 Controlling Multiple Cyclones
CycloneControlConsole.exe ­cyclone=USB1,10.0.1.2,10.0.1.3 ­ launchimage=2
This example connects to three separate Cyclone units. Two units are connected via USB (10.0.1.1 and 10.0.1.2) and the third is connected via Ethernet (10.0.1.3). The three Cyclone units are configured to execute image #2. 8.3.3.3 Programming Dynamic Data
CycloneControlConsole.exe ­cyclone=CycloneFX_Table1,CycloneFX_Table2 ­launchimage=1 ­putdynamicdata=2,1080,45,44,49,53,4F,4E
Here, a Cyclone is connected via the Serial port and is identified by name rather than IP address. After executing image #1 on both cyclones, we write 6 bytes of dynamic data on Cyclone #2 starting at address 0x1080. Note that all parameters for the "-putdynamicdata" command should be hexadecimal values.

User Manual For Cyclone LC Programmers

99

8.3.3.4 Executing more than 1 image on the same Cyclone
CycloneControlConsole.exe ­cyclone=CycloneFX_1,CycloneFX_2 ­launchimage=1 ­launchimage=2

Two Cyclone units are connected via Ethernet and both Cyclone units execute their first image. Afterwards, the both Cyclones will execute their second image. This example is useful when the processor's code is split into two separate images. For example, one image could contain the bootloader while the second image contains the main application code.
8.3.3.5 Image Management ­ Modifying External Images
CycloneControlConsole.exe ­cyclone=USB1 ­eraseallexternalimages ­addexternalimage=c:\images\externalImage1.SAP
In this example, a Cyclone unit is connected via USB and it has an image stored on its external memory card. The external image is erased and a new one is added. This type of command should only be used when an image needs to be updated.
8.3.3.6 Image Management ­ Modifying Images on Two Cyclones in Parallel
CycloneControlConsole.exe ­cyclone=USB1,USB2 ­eraseallinternalimages ­addinternalimage=c:\images\Image1.SAP

In this example, two Cyclone units connected via USB have their images erased and a new image is added to both Cyclone units. This type of command should only be executed when images need to be updated.

8.4

Cyclone Control GUI

As part of the Cyclone Control Suite, PEmicro includes the Cyclone Control GUI, a graphical application that gives the users access to all the functions of the latest Cyclone Control.

Note:

This new application replaces the previous Image Manager Utility and Cyclone Config IP Utility. The Cyclone Control GUI allows users to add and remove images from the internal Cyclone memory as well as from the external memory cards. The utility also allows the user to view and edit Cyclone properties, to view the Cyclone LCD remotely, to view and add Cyclone Licenses, and to view and manage Serial Files and Encryption Keys.

The utility is composed of three main parts: a connection dialog, the control tabs, and a status window.

User Manual For Cyclone LC Programmers

100

8.4.1

Figure 8-2: Areas of the Cyclone Control GUI
The Connection Dialog
Allows the user to specify a Cyclone to connect with, as well as specify the connection options. The utility will always automatically upgrade the firmware of a Cyclone if the firmware in the Cyclone is outdated. However, firmware update can also be forced by using the checkbox in File>Force Firmware Update. This option will update the firmware on the Cyclone with the latest firmware in the same folder as the Cyclone Control GUI.
At launch, the Cyclone Control GUI will show all the Cyclones detected on the network and those attached by USB connections in a drop-down list. Cyclones can also be connected to by using the "Specify Cyclone" checkbox and specifying a Cyclone by identifier. This identifier can by the Cyclone name, its IP address or its port number.

8.4.2

Figure 8-3: Select Cyclone From Drop Down
Once the Cyclone is selected, clicking on the "Connect" button will bring a series of tabs that will allow full access to the Cyclone.
The Control Tabs The control tabs allow access to the Cyclone. Through these tabs you can view, add, and erase Cyclone images, you can view and modify properties, you can modify licenses, see the Cyclone

User Manual For Cyclone LC Programmers

101

screen remotely and view/manage Serial Files and Encryption Keys.

8.4.2.1

Images Tab
The Images tab allows the user to view and modify the Cyclone images both in internal Cyclone memory and on external memory cards. To add a new image to the Cyclone, click on the "Add Image Internal" button and selected the image you want to add. For the changes to take effect, the "Apply Changes" button needs to be clicked, this will place the image in the Cyclone memory.

Figure 8-4: Images Tab - Image Ready to Store
CYCLONE FX programmers and CYCLONE programmers with the SDHC Port Activation License can also store images in external memory (an SDHC card). The storage area for the Add Image button is toggled between Internal and External by clicking on the drop down arrow on the right of the "Add Image" button. Users can also right-click on an uncommitted image to toggle the storage between Internal and External.

User Manual For Cyclone LC Programmers

102

Figure 8-5: Changing Storage Area - Right Click or Drop-Down Selections
Note: An image displayed in blue is not yet committed, so disconnecting from the Cyclone before the "Apply Changes" button is clicked will discard any changes not committed.
Erasing an image can be done by clicking on the trashcan icon at the left of the image, it can also be done by selecting the image and click the DELETE key on the keyboard. The "Apply Changes" buttons must be clicked for any changes to the Cyclone to take place. To format the external memory card click on the "Format External Card" button. This will erase all image information stored in the external card.
8.4.2.1.1 Categories
The following information is displayed for each image in the Images Tab: Delete Image - Clicking the trash icon will designate an image for deletion. Apply Changes must be clicked to execute this action. Number - Displays the Cyclone's numbering for each image. Name - Displays the Image Name. CRC - Displays the CRC value for each image. Storage Area - "IN" designates that the image is stored in the Cyclone's internal memory; "EX" designates that it is stored in external memory (SDHC Card). Status - This displays whether the image is "Stored" on the Cyclone, "Ready to store", or "Ready to erase". A stored image that is encrypted but missing its ImageKey will always show "Key Missing!" to indicate that the user must provision the Cyclone with this key in order to program that encrypted image. Encryption - Displays "Encrpyted" for encrypted images, and "None" for images that have not been encrypted.
For more about encrypted programming images, please see Section 6.1.10 - ProCryption Security Features.
8.4.2.1.2 View Image Properties
From this tab a user can also access the image properties of images in the Cyclone. Just right click on the image then click on "View Image Properties" and a window with public image properties will pop up.

User Manual For Cyclone LC Programmers

103

Figure 8-6: Image Properties Window
Properties like the image name, the voltage settings, image CRC, encryption info, and all current serial numbers can be viewed from this window. Use this feature to make sure your image settings are correct or check that the serial numbers change accordingly.
8.4.2.2 Properties Tab

Figure 8-7: Properties Tab
The properties tab shows all the network, Cyclone and image properties. It also shows properties for the supported features of the Cyclone. From this tab the Cyclone firmware and logic versions, the cyclone type, and the number of images are available. Also from this tab some of the properties can be modified.
8.4.2.2.1 Modifying A Cyclone Property Some properties in the Cyclone are modifiable. Only the properties that can be modified will show three dots to the right of the property when the property is selected.

Figure 8-8: Modifying Cyclone Properties
Clicking on the three dots or double clicking on the property value will bring up an edit window. Write the new property value and click "OK", the property window will refresh and the value

User Manual For Cyclone LC Programmers

104

showed will be the updated value of the property.

8.4.2.3

The Remote Display Tab
This tab will show the current display of the Cyclone. The utility checks every second for changes in the display and updates the image to the current display. This image is also clickable so clicks on the virtual screen are also registered by the Cyclone.

Figure 8-9: Remote Display & Control of Cyclone Screen

8.4.2.4

Licenses Tab
New licenses can be added to the Cyclone using the Licenses tab. Clicking on "Add New License" will prompt the PEmicro License Activation Form. This form takes in the Installation Code for a product and can automatically validate and register the installation.
This tab also shows the current licenses active in the Cyclone, including the Cyclone Control Advanced Automation License, SDHC Port Activation License, and ProCryption Security Activation License.

Figure 8-10: Licenses Tab

8.4.2.5 Note:

Serial Files Tab
The Serial Files Tab displays any Serial Files that are on the Cyclone. Serial Files can be "deleted" with the "Delete Serial File" button, but in this case it simply means that they will not be displayed. An image file that uses a "deleted" Serial File will simply cause the file to re-appear and resume with its next serial number.
Older images may reference Serial Files that are image-specific and cannot be shared among images (like current Serial Files). These will not appear in the Serial Files tab. The Cyclone menu

User Manual For Cyclone LC Programmers

105

can be used to make changes to the serialization of these images.

Figure 8-11: Serial Files Tab

8.4.2.6

Encryption Keys Tab
CYCLONE FX programmers and CYCLONE programmers with the ProCryption Security Activation License are able to encrypt programming images with a user-generated ImageKey. In order to load an encrypted image onto a Cyclone, or to program with an encrypted image once it is on the Cyclone, the ImageKey used to encrypt that image must be present on the Cyclone.
The Encryption Keys tab displays any ImageKeys that reside on the Cyclone. The Name and unique ID number for each ImageKey is shown.

Figure 8-12: Encryption Keys Tab
The Add Encryption Key button allows the user to browse to an ImageKey that they wish to add to the Cyclone. Encrypted (eSAP) programming images cannot be loaded onto the Cyclone unless the ImageKey that was used to encrypt them is present on the Cyclone. The transfer of an ImageKey to a Cyclone using the Cyclone Control Suite is always secured by encrypting the ImageKey with an RSA public key specific to the Cyclone that it is connected to.
The Delete Encryption Key button will delete the selected ImageKey from the Cyclone. The user

User Manual For Cyclone LC Programmers

106

8.4.3

should bear in mind that if the ImageKey is missing for an eSAP image, that image will be locked and cannot be programmed.
The Status and Error Window:

8.5
8.5.1

Figure 8-13: Status & Error Window
This section of the Cyclone Control GUI displays the status of the utility as well as any errors during the connection or any of the actions performed by the utility. It'll show detailed errors on images that failed to be properly added or actions that require additional licensing.
This new status and error window increases the visibility of the user into the tasks the utility is performing as well as the issues that may arise.
License
The Cyclone Control Suite software does not need a license to operate when using the standard features with any touchscreen Cyclone or when using advanced features with a Cyclone FX. When using the advanced automation features of the SDK or Console with non-FX cyclones, a "Cyclone Control Advanced Automation License" needs to be present in the Cyclone. This advanced license is available for purchase for the Cyclone LC programmers.
Information on how to install the license for your Cyclone LC programmer is available in CHAPTER 8 - CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE).
Advanced automation features in the Cyclone Control Suite are not available for older, nontouchscreen Cyclone models (Cyclone MAX, Cyclone PRO, Cyclone for STMicro, and Cyclone Renesas). Please use the Classic Cyclone Automated Control Package when using advanced features with these Cyclones
Hardware Licensing
PEmicro's Cyclone licensing is hardware-based to provide the user with added flexibility. For example, a customer in Germany can configure a Cyclone for a contract manufacturer in China, without requiring the contract manufacturer to re-license PEmicro's software. The manufacturer can simply download any PEmicro software, and as long as a licensed PEmicro hardware is available on site, they can simply use the product.
Additionally, a hardware license does not require a networked or USB connection to a host PC, thereby making possible stand-alone operations that may require other licensing (such as the use of an SDHC card). Hardware licensing also simplifies the management of personal computers by IT departments. PCs can be replaced, upgraded, or re-formatted, without any impact to the functionality and /licensing in place on PEmicro's hardware.
One last beneficial feature of the hardware licensing mechanism is the fact that it requires no change to how licenses are obtained from PEmicro. It preserves backwards compatibility, and it maintains the same traditional licensing workflow that was previously used to license PEmicro software.

User Manual For Cyclone LC Programmers

107

9 SAP IMAGE COMPILER (SCRIPTED PROGRAMMING & IMAGE CREATION)
PEmicro's Cyclone SAP Image Compiler, or CSAP, is an essential component in the Stand-Alone Programming (SAP) image creation process. It is designed to work in tandem with the Cyclone Image Creation Utility, by running in the background, but it can also be called directly by the user. The CSAP image compiler typically takes the .CFG file that was generated by the Image Creation Utility and uses it to locate and combine all of the components that will be included in the specific SAP image that is being created. However the user can also use a command line to submit a CFG file and various Command-Line Parameters directly to the image compiler. This allows users to write scripts that can automate the image creation/re-creation process.
In order for the user to do this, they will need to know what Command-Line Parameters are available and how they are used, and what items can/must be included in a CFG file, including Programming Commands and Configuration Commands. There is also a specific Command-Line Parameter that allows the user to easily substitute values inside a specific CFG file. This can enable a single CFG file to be used to create different SAP images.

9.1
9.1.1

Launching From the Command Line
The image compiler can be launched from the command line to create a SAP image. Below is an example of a command-line that the user might put together, along with descriptions of its various components.
Command-Line Example Below is an example of using the command line to launch CSAP for ARM Cortex devices. The command line specifies where to locate the .CFG file and other necessary information.

>csapacmpz.exe "C:\MyWorkspace\MyProject\KL25Z128_script.cfg" /imagefile "C:\MyWorkspace\MyProject\KL25Z128_image.sap"

Most command-line parameters can be used with any device, but some are specific to certain architectures or device types.

9.1.1.1

CSAP Executable
The user must first specify the particular CSAP executable that is compatible with their device. See the area of the example in green, which is specifically for ARM devices:

>csapacmpz.exe "C:\MyWorkspace\MyProject\KL25Z128_script.cfg" /imagefile "C:\MyWorkspace\MyProject\KL25Z128_image.sap"

Below is a list of which executable corresponds to which architecture/device type.

Target Architecture / Executable Name
ARM-based devices (all manufacturers) : CSAPACMPZ.exe MAC71XX, MAC72XX: CSAPARMZ.exe HC(S)12(X): CSAPBDM12Z.exe ColdFire V1: CSAPBDMCFV1Z.exe ColdFire V2, V3, V4: CSAPBDMCFZ.exe MPC5xx/8xx: CSAPBDMPPCZ.exe DSC: CSAPDSCZ.exe HCS08: CSAPHCS08Z.exe

User Manual For Cyclone LC Programmers

108

HC08: CSAPMON08Z.exe MPC55XX-57XX: CSAPPPCNEXUSZ.exe
RS08: CSAPRS08Z.exe S12Z: CSAPS12ZZ.exe STM8: CSAPWIZ01.exe

9.1.2

Filename and Additional Command-Line Parameters
After specifying the executable, the user must also include the [filename] parameter, which represents the path and filename of the .CFG file. This is shown in blue in the example below. The user may also include one or more other command-line parameters. The area of the example in violet shows these other command-line parameters.

>csapacmpz.exe "C:\MyWorkspace\MyProject\KL25Z128_script.cfg" /imagefile "C:\MyWorkspace\MyProject\KL25Z128_image.sap"

9.1.3

List of Valid Command-Line Parameters Here is the listing of valid parameters:

[executable] Specifies the particular CSAP executable that is compatible with the user's device. Mandatory.

[filename] A configuration file containing configuration commands and comments, default = PROG.CFG. Mandatory.

[?] Use the '?' character option to cause the utility to wait and display the result of configuration in the image compiler window. If the user does not use a batch file to test error level, this provides a method to display the configuration result. This option should be the FIRST command-line option.

[hideapp]

This will cause the CSAP executable programmer to NOT display a visual presence while running, with the exception of appearing on the taskbar. (32bit applications only)

[/logfile logfilename]

This option opens a logfile of the name "logfilename" which will cause any information which is written to the status window to also be written to this file. The "logfilename" should be a full path name such as c:\mydir\mysubdir\mylog.log.

Note: When using Windows, if the logfilename path or filename include any white spaces then the logfilename path and filename must be surrounded by double quotation marks.

[/imagefile imagefilename]Used when the SAP file should be saved to disk instead of stored on the Cyclone. This specifies the path and filename for the SAP file. A user may later update a Cyclone with this image file.

Note: If the image path or filename include any white spaces then the image path and filename must be surrounded by double quotation marks.

User Manual For Cyclone LC Programmers

109

[imagecontent]

This command-line parameter is a string that can be used to describe the SAP image, whether it is stored in a file or on the Cyclone. If the configuration command :DESCRIBEIMAGE is also present in the .CFG file, this will be overwritten.

[paramn=s]

This is a type of command-line parameter that can be used within the .CFG file as a placeholder for data, and this data can then be specified on the command-line. Multiple scripts can potentially reference the same .CFG file, each specifying different data on the command-line.

The n is a numeral, which allows multiple parameters to be used within the same .CFG file.

See Section 9.2.4 - Using Command Line Parameters Inside a .CFG File for more information and examples.

9.2
9.2.1

Configuration (.CFG) File Contents
A Configuration (.CFG) file includes programming commands and the location of the binary files and programming algorithm to be used during programming. It may also include configuration commands and may refer to utilities that can augment the programming process, such as serialization, or setup information for use of a bar code scanner during programming.
Because the CFG file is essential to the process of creating a SAP image, the command-line used to call CSAP must always use the [filename] parameter to specify a .CFG file. This file will instruct the image compiler which components will be used to create the eventual SAP image and where to them, among other things.
Sample .CFG File
A .CFG file is a pure ASCII file that includes one command per line. It will always include two main types of commands: Configuration Commands and Programming Commands. It can also include a certain type of command-line parameter that can serve as a placeholder for some of the script contents.
Below is a sample .CFG for NXP's Kinetis KL25Z128 device. Lines in the file that begin with semicolons are comment lines.
The first several lines are comments that describe some of the attributes of the programming setup. The next several lines, which begin with a colon, are Configuration Commands that are read before programming. The final several lines are the Programming Commands that will be executed during the programming process.
; Automatically generated configuration file ; Silicon Manufacturer is NXP ; Silicon Architecture is ARM Based (Kinetis, LPC, etc.) ; :ALLOWOUTOFRANGE 1 :DEVICE NXP_K7x_K70FN1M0M15 :USESWD 1 :DEBUGFREQUENCY 5560 :SAPGUIVERSION 352E3737 :PROVIDEPOWER :POWERVOLTAGE 3.0 :POWERDOWNDELAY 250 :POWERUPDELAY 250 :KEEPPOWERON 0

User Manual For Cyclone LC Programmers

110

:CUSTOMTRIMREF 31250.00 :NEWIMAGE :DESCRIBEIMAGE Test_K70 CM C:\PEMicro\cyclone\supportfiles\supportFiles_ARM\NXP\K7x\freescale _k70fn1m0m15_1x32x256k_pflash.arp SS C:\test\nxp\armcortex\mk_x_32_pflash_dflash_m5_05A0_1FFF.s19 EN ;Erase if not Blank PM ;Program Module VC ;Verify Checksum

9.2.2

Configuration Commands
Configuration Commands are commands that will be executed at startup, before the programming process. You can see configuration commands used inside a sample .CFG file above in Section 9.2.1 - Sample .CFG File. They listed are in the middle of the file. They always begin with a colon.
A listing of valid Configuration Commands and their formats is included below.

9.2.2.1 Target Power Related Configuration Commands

9.2.2.1.1 :PROVIDEPOWER n Processors: All (EXCEPT MON08) Determines whether the Cyclone should provide power to the target. (This is the same as legacy option :USEPRORELAYS n).
Note: Not all hardware interfaces support this command. Valid values of n are:
0 : Cyclone does NOT provide power to target. (default) 1 : Enable Cyclone to provide power to target.

9.2.2.1.2 :POWERVOLTAGE n.n

Processors: All

Use this command if the Cyclone is providing/switching power to the target, otherwise omit this command. Specifies the target voltage as a real number. Acceptable range is from 1.6V - 5.0V.

:POWERVOLTAGE 3.3

Specifies target voltage as 3.3V

9.2.2.1.3 :KEEPPOWERON n
Processors: All Determines whether power provided to the target should be turned off when the application terminates. NOTE: Not all hardware interfaces support this command. Valid values of n are:
0 : Turn power off upon exit (default) 1 : Keep power on upon exit

9.2.2.1.4 :POWERDOWNDELAY n
Processors: All Amount of time to delay when the power to the target is turned off for the target's power supply to drop to below 0.1v. n is the time in milliseconds.

9.2.2.1.5 :POWERUPDELAY n
Processors: All
Amount of time to delay when the power to the target is turned on OR the target is reset, and before the software attempts to talk to the target. This time can be a combination of power on time and reset time (especially if a reset driver is used). n is the time in milliseconds.

User Manual For Cyclone LC Programmers

111

9.2.2.2 Trim Related (If supported) Configuration Commands
9.2.2.2.1 :CUSTOMTRIMREF nnnnnnnn.nn
Processors: All Desired internal reference clock frequency for the "PT; Program Trim" command. This frequency overrides the default internal reference clock frequency. Valid values for "nnnnnnnn.nn" depend on the particular device being programmed. Please refer to the electrical specifications of your device for valid internal reference frequency clock range.

Where: nnnnnnnn.nn : Frequency in Hertz with two decimal places

9.2.2.3 Information Processing Configuration Commands

9.2.2.3.1 :CLEARSTATUS n
Processors: All Specifies the amount of time after programming, in milliseconds, before the Success indicator (LED) will be turned off.

9.2.2.3.2 :DESCRIBEIMAGE string
Processors: All string This is a string that describes the SAP image. Will overwrite the command-line parameter
"imagecontent" if both are present in the .CFG file. Example:
:DESCRIBEIMAGE KL25Z128 TEST IMAGE

9.2.2.3.3 :ALLOWOUTOFRANGE n

Processors: All

Sets whether programming will continue when data is out of range.

:ALLOWOUTOFRANGE 1

Allows programming to continue when some data is out of range (addresses not in module). Out of range data is ignored.

:ALLOWOUTOFRANGE 0

Requires all programming data to be in range of the module. Out of range data causes an error on image creation.

9.2.2.4 Image Security Configuration Commands

9.2.2.4.1 :PROGRAMLIMIT n
Processors: All Sets a limit to the number of devices that the Cyclone may program, until this limit is removed or reset.

9.2.2.4.2 :DATERANGE mm/dd/yyyy mm/dd/yyyy

Processors: All

Sets a starting date and ending date for Cyclone programming operations. The Cyclone will then only allow devices to be programmed on or between these two dates, until the date limit is removed or reset. Dates always refer to the Cyclone's internal calendar. The character between the two dates should be a single space. The dates should be listed in chronological order, first to last.

Example:

:DATERANGE 05/10/2018 05/12/2018

Allows Cyclone programming operations on

User Manual For Cyclone LC Programmers

112

5/10/2018, 5/11/2018, and 5/12/2018. Does not allow it on any other dates.

9.2.2.4.3 :ERRORLIMIT n
Processors: All
Sets a limit to the number of errors that may occur while the Cyclone is programming devices. Once this limit has been reached, the Cyclone will no longer program devices until the error limit is removed or reset.

9.2.2.5 Image Launch Settings Configuration Commands

9.2.2.5.1 :BARFILE barfile
Processors: All Specifies that a .BAR file will be used during programming (programming initiated by bar code scanner). barfile Indicates the path and filename of the .bar file. Example:
:BARFILE C:\PEMicro\cyclone\imageCreation\barcodeTest.bar

9.2.2.6 Connection Related Configuration Commands (ARM)

9.2.2.6.1 :DEVICE string
Processors: ARM, DSC, MAC7xxx, TriCore
For ARM and TriCore devices, this is a mandatory parameter that specifies the device. It is required because the debug protocol changes between manufacturers and sometimes also between families or devices.
Where:
string: represents the device and follows the "VENDOR_FAMILY_DEVICE" format.
For ARM and TriCore devices, the easiest way to obtain the device string is from the Device Selection dialog in the Cyclone Image Configuration Utility software. In the PEMICRO Connection Manager, click "Select New Device" to open the Device Selection dialog. Expand the device tree to find your device, then right-click and select "Copy Device String to Clipboard."

9.2.2.6.2 :DEBUGFREQUENCY n

Processors: ARM, ColdFire, PPC, MAC7xxx, TriCore

Specifies the communications frequency with the target device.

n

Frequency in Kilohertz.

9.2.2.6.3 :USESWD n Processors: ARM, MAC7xxx Allows the user to specify SWD (single wire debug) mode instead of JTAG mode. 0 Specifies that JTAG mode will be used during communications (default). 1 Specifies that SWD (single wire debug) mode will be used during communications.

9.2.2.6.4 :JTAGTAPNUM n
Processors: ARM, MAC7xxx The JTAG Tap Number is the index of the target device in the daisy chain. The first device connected to TDI is index 0, the next is index 1, and so on. The index of the last device connected to the TDO of the debugger is the total number of devices in the chain minus 1.
Note: This command is mandatory for JTAG daisy chain configurations. It is also important to specify

User Manual For Cyclone LC Programmers

113

JTAG communications using the :USESWD 0 command/value.

n

Specifies the index number of a device in the daisy chain.

For more information on how to program or debug with a daisy chain setup, read:

http://www.pemicro.com/blog/index.cfm?post_id=136

9.2.2.6.5 :JTAGPREIR n
Processors: ARM, MAC7xxx Every JTAG device has an IR register that is a certain width in bits. In the daisy chain the number of Pre-IR bits is the sum of all of the IR registers between your device and the TDO pin.
Note: This command is mandatory for JTAG daisy chain configurations. It is also important to specify JTAG communications using the :USESWD 0 command/value.

n

Specifies the total length of IR registers following the target device. The first device in

the daisy chain is index 0.

For more information on how to program or debug with a daisy chain setup, read:

http://www.pemicro.com/blog/index.cfm?post_id=136

9.2.2.6.6 :RSTLOWPOSTSAP Processors: All Drives the RESET signal LOW before and after SAP operations.

9.2.2.7 Connection Related (S08, S12, ColdFire V1, RS08, S12Z) Configuration Commands

9.2.2.7.1 :DRIVEBKGDLOW n

Processors: S08, S12, CFV1, S12Z Note: Not RS08.

By default, the BKGD signal is driven low before and after programming operations are complete.

0

Do NOT drive BGND low before and after programming operations.

non-zero or missing Drive BGND signal low before and after programming operations.

Example:

:DRIVEBKGDLOW 0 Does NOT drive the BKGD signal LOW after operations are complete.

9.2.2.7.2 :RSTLOWPOSTSAP Processors: All Drives the RESET signal LOW before and after SAP operations.

9.2.2.8 Connection Related Configuration Commands (ColdFire V2, V3, V4)

9.2.2.8.1 :USEPSTSIGNALS n Processors: ColdFire Specifies whether to use PST signals during debug. 0 Do not use PST signals. 1 Use PST signals.

9.2.2.8.2 :RSTLOWPOSTSAP Processors: All Drives the RESET signal LOW before and after SAP operations.

User Manual For Cyclone LC Programmers

114

9.2.2.9 Connection Related (MPC5xxx, SPC5xxx) Processors

9.2.2.9.1 :DEBUGFREQUENCY n Processors: ARM, ColdFire, PPC, MAC7xxx, DSC, PPCNexus Specifies the communications frequency with the target device. n Frequency in Kilohertz.

9.2.2.9.2 :UNCENSOR n
Processors: PPCNexus, TriCore This parameter should be used if 64-bit and 256-bit censorship passwords are needed to bypass security. Note: The ASCII version of the password must have each long word separated by a dash.

n

Password represented as a hexadecimal value, with no symbols or spaces

9.2.2.9.3 :RSTLOWPOSTSAP Processors: All Drives the RESET signal LOW before and after SAP operations.

9.2.2.10 Connection Related - DSC Processors

9.2.2.10.1 :DEVICE string Processors: ARM, DSC, MAC7xxx, TriCore Describes the device being programmed. string Describes the device being programmed.

9.2.2.10.2 :RSTLOWPOSTSAP Processors: DSC, STM8 Drives the RESET signal LOW before and after SAP operations.

9.2.2.11 Connection Related (Infineon TriCore TC1xx, TC2xx, TC3xx) Processors

9.2.2.11.1 :DEVICE string
Processors: ARM, DSC, MAC7xxx, TriCore
For ARM and TriCore devices, this is a mandatory parameter that specifies the device. It is required because the debug protocol changes between manufacturers and sometimes also between families or devices.
Where:
string: represents the device and follows the "VENDOR_FAMILY_DEVICE" format.
For ARM and TriCore devices, the easiest way to obtain the device string is from the Device Selection dialog in the Cyclone Image Configuration Utility software. In the PEMICRO Connection Manager, click "Select New Device" to open the Device Selection dialog. Expand the device tree to find your device, then right-click and select "Copy Device String to Clipboard."

9.2.2.11.2 :DEBUGFREQUENCY n Processors: ARM, ColdFire, PPC, MAC7xxx, DSC, PPCNexus, TriCore Specifies the communications frequency with the target device. n Frequency in Kilohertz.

User Manual For Cyclone LC Programmers

115

9.2.2.11.3 :RSTLOWPOSTSAP Processors: All Drives the RESET signal LOW before and after SAP operations.

9.2.2.11.4 :UNCENSOR n
Processors: PPCNexus, TriCore This parameter should be used if 64-bit and 256-bit censorship passwords are needed to bypass security. Note: The ASCII version of the password must have each long word separated by a dash.

n

Password represented as a hexadecimal value, with no symbols or spaces

9.2.2.12 Connection Related - MON08 Processors
When using MON08 devices, the user must specify :POWERVOLTAGE and :POWERUPDELAY & :POWERDOWNDELAY.

9.2.2.12.1 :DEVICECLOCK n
For Class 5, 6, 7, and 8 devices. Controls whether the Cyclone should drive a clock to the target or whether the PEmicro interface should tristate its clock output. Valid values of n are:
0 : Clock driven by Cyclone. Must use :OUTPUTCLOCK to specify. 1 : Target self-clocked, Cyclone clock output disabled

9.2.2.12.2 :OUTPUTCLOCK n Specifies the clock when :DEVICECLOCK is set to 0 (driven by Cyclone). Valid values of n are: 0 : 4.9152 MHz 1 : 9.8304 MHz

9.2.2.12.3 :CLOCKDIVIDER n
For Class 5, 6, 7, and 8 devices. Often one of the port pins of the target processor controls the ratio of the BUS clock to the External clock. Valid values of n are:
0 : Divide by 2 (usually and if applicable) 1 : Divide by 4 (usually and if applicable)

9.2.2.12.4 :BAUD n
Sets the baud rate to n. Serial port connection only If :BAUD is specified, include :FORCEPASS followed by :SECURITYCODE.

9.2.2.12.5 :FORCEPASS
Specifies that security should be passed on startup of the software instead of waiting for an EM (Erase Module) command. The :SECURITY code command must also be provided.

9.2.2.12.6 :SECURITYCODE hh hh hh hh hh hh hh hh
Specifies the 8 bytes of security code to use at startup which correspond to the addresses $FFF6$FFFD of the target HC08 device. The parameter for this is a string containing 8 bytes of data in HEX separated by white spaces.

9.2.2.12.7 :DEVICETYPE string
Specifies the target device family. As an example, the device type for a 68HC908KX8 would be KX. The allowed device type values are:
AB,AP,AS,AT,AZ,BD,EY,GP,GR,GR4/8,GT,GZ,JB12,JB16, JB1/8,JG,JK,JL,JR,JW,KX,LB,LD, LJ,LK,LT,LV,MR4/8,MR16/32,QB,QC,QL,QT,QY,RF,RK,SR

User Manual For Cyclone LC Programmers

116

9.2.2.13 Connection Related - STMicroelectronics' STM8 Processors

9.2.2.13.1 :ARCHTYPE n Processors: STM8 Specifies the STM8 family via the numeral n, where n indicates the following: 161 = STM8S/STM8A 162 = STM8L101X 163 = STM8L15X 164 = STM8L16X 165 = STM8AF 166 = STM8AL

9.2.2.13.2 :COMMSMODE 0 Processors: STM8 Indicates that communications speed should be controlled automatically.

9.2.2.13.3 :FORCEPASS
Processors: STM8
If this command is present, read-out protection will be ignored, i.e. the target will be unsecured and the programming process will continue.
If this command is missing, read-out protection will NOT be ignored. If the device is protected the programming process will not proceed.

9.2.2.13.4 :RSTLOWPOSTSAP Processors: All Drives the RESET signal LOW before and after SAP operations.

9.2.3

Programming Commands
Programming Commands are the commands that will be executed during the programming process. These are the main commands that will manipulate and verify data on your device. A list of programming commands and their formats is included below.
See Section 9.2.1 - Sample .CFG File to view programming commands within a CFG file. The example programming commands are at the bottom of the file.
Note: The command parameter formats starting_addr, ending_addr, base_addr, and byte, word are hexadecimal by default.

BM Blank check module. BR starting_addr ending_addr Blank check range. CM Choose module (algorithm) file. Note: Certain modules may require a base address to be
specified CU either EB starting_addr ending_addr Erase byte range. EW starting_addr ending_addr Erase word range. EM Erase module. EN Blank check and erase GO Starts device running. Can be used as final command if you want the device to run for
testing. Should be immediately preceded by an 'RE' command. PB starting_addr byte ... byte Program bytes. PF feature_ID starting_addr Program feature data. feature_ID must be: datestr, datetimestr,

User Manual For Cyclone LC Programmers

117

9.2.4

barcodestr, or runtestdata. See Section 6.1.6.9 - Program Feature Data. PW starting_addr word ... word Program words. PM Program module. PT [address] Program trim (Devices with trim only. Address is only necessary for devices that have no dedicated non-volatile trim register)
RE Reset chip. SS path Specify binary data file (S19/Elf/Hex) Path indicates file path to the binary.
VC Verify the programmed device using a checksum VM starting_addr ending_addr Verify module. VR starting_addr ending_addr Verify range. VV type Verify module CRC. Type is CRC8 or CRC16. DE timeinms - Delays "timeinms" milliseconds
Using Command Line Parameters Inside a .CFG File The user may wish to make their .CFG files more versatile by inserting one or more placeholders into the script, and then specifying the values for those placeholders later, on the command line, when calling the CSAP executable that will references that script. The command-line parameter /PARAMn=s can be used to insert text into a .CFG file. It can replace any part of the script including programming commands, filenames, and parameters. n is a numeral from 0..9, which allows you to use multiple versions of this command line parameter in a .CFG file. s represents a string which will replace any occurrence of /PARAMn in the script file. As an example, the following section of a .CFG script features three instances of /PARAMn=s: / PARAM1, /PARAM2, and /PARAM3:
RE ;Reset the MCU CM /PARAM1 ;Choose Flash Module EM ;Erase the module BM ;Blank Check the module SS /PARAM2 ;Specify the S19 to use PM ;Program the module with the S19 /PARAM3 ;Verify the module again
When the user calls the CSAP executable that will reference this CFG file they will need to specify the values of these parameters on the command line. See the example below, where the first of these parameters is used to specify a programming algorithm (.SRP), the second an .S19 file, and the third a programming command (VM).

CSAPACMPZ /PARAM1=C:\PEMICRO\Freescale_MK40X256_PFlash_DFlash.ARP "/PARAM2=C:\PEMICRO\EXAMPLE FILES\TEST.S19" /PARAM3=VM

Note: Notice that /PARAM2 is enclosed in double quotation marks. This is because the parameter has a space in its value (Example Files). The surrounding double quotation marks are required in this

User Manual For Cyclone LC Programmers

118

situation, in order to indicate to Windows that it is a single parameter.
The complete example command line would be as below (note that this is one continuous line; no line breaks):

C:\PROJECT\CSAPACMPZ C:\PROJECT\GENERIC.CFG / PARAM1=C:\PEMICRO\Freescale_MK40X256_PFlash_DFlash.ARP "/ PARAM2=C:\PEMICRO\EXAMPLE FILES\TEST.S19" /PARAM3=VM

9.2.5

Sample Batch File
Here is an example of how to call a command-line programmer and test its error code return in a simple batch file. Sample batch files are given for both Windows 95/98/XP and Windows 2000/NT/ XP/Vista/7/8/10.

9.2.5.1 Windows NT/2000/Vista/7/8/10:
C:\PEMicro\CYCLONE\IMAGECREATION\IMAGECREATIONSUPPORTFILES\CSA PACMPZ.EXE C:\PROJECT\ENGINE.CFG PORT=USB1 if errorlevel 1 goto bad goto good :bad ECHO BAD BAD BAD BAD BAD BAD BAD BAD :good ECHO done
Note: Path names of files that are relative to the CSAP executable can also be used.

9.3

CSAP Error Returns

An Error code is returned by the Image Compiler so that a script file or an application launching the Image Compiler can check for it. The error codes used are:

0 - Program completed with no errors. 1 - Canceled by user. 2 - Error reading S record file. 3 - Verify error. 4 - Verify canceled by user. 5 - S record file is not selected. 6 - Starting address is not in module. 7 - Ending address is not in module or is less than starting address. 8 - Unable to open file for uploading. 9 - File write error during upload. 10 - Upload canceled by user. 11 - Error opening algorithm file. 12 - Error reading algorithm file. 13 - Device did not initialize. 14 - Error loading .PCP file. 15 - Error enabling module just selected. 16 - Specified S record file not found.

User Manual For Cyclone LC Programmers

119

17 - Insufficient buffer space specified by .PCP to hold a file S-record. 18 - Error during programming. 19 - Start address does not point into module. 20 - Error during last byte programming. 21 - Programming address no longer in module. 22 - Start address is not on an aligned word boundary. 23 - Error during last word programming. 24 - Module could not be erased. 25 - Module word not erased. 26 - Selected algorithm file does not implement byte checking. 27 - Module byte not erased. 28 - Word erase starting address must be even. 29 - Word erase ending address must be even. 30 - User parameter is not in the range. 31 - Error during algorithm-specified function. 32 - Specified port is not available or error opening port. 33 - Command is inactive for this .PCP file. 34 - Cannot enter background mode. Check connections. 35 - Not able to access processor. Try a software reset. 36 - Invalid algorithm file. 37 - Not able to access processor RAM. Try a software reset. 38 - Initialization canceled by user. 39 - Error converting hexadecimal command number. 40 - Configuration file not specified and file prog.cfg does not exist. 41 - Algorithm file does not exist. 42 - Error in io_delay number on command line. 43 - Invalid command line parameter. 44 - Error specifying decimal delay in milliseconds. 47 - Error in script file. 49 - Cable not detected 50 - S-Record file does not contain valid data. 51 - Checksum Verification failure - S-record data does not match MCU memory. 52 - Sorting must be enabled to verify flash checksum. 53 - S-Records not all in range of module. (see "v" command line parameter) 54 - Error detected in settings on command line for port/interface 60 - Error calculating device CRC value 61 - Error - Device CRC does not match value given 70 - Error - CSAP is already running 71 - Error - Must specify both the INTERFACE and PORT on the command line 72 ­ The selected target processor is not supported by the current hardware interface.

User Manual For Cyclone LC Programmers

120

10 ETHERNET CONFIGURATION
This section describes the mechanism used by the Cyclone device to transact data over an Ethernet network. It primarily focuses on the User Datagram Protocol (UDP), which is a popular method for sending data over a network when the speed of a data transaction is of more concern than the guarantee of its delivery. The Cyclone takes advantage of the UDP protocol's penchant for speed, and adds an extra layer of logic to guarantee the delivery of UDP packets in order to offer a best-of-both-worlds solution.

10.1

Network Architectures
Before delving into the innards of Ethernet message passing, it is prudent to briefly describe the different network architectures in use today, and how they pertain to the operation of the Cyclone. Computers are, of course, connected to one another through intermediary devices in order to form networks. There are several classes of these intermediary devices, but they generally fall into one of the following three groups:
Hubs
At the most basic level, computers are connected to one another through a Hub. A Hub is a device with several ports that are used to connect multiple computers together. It is a repeater device ­ a Hub simply copies the data incoming on one port as data outgoing on the other ports. In this manner, if there are four computers connected through a Hub, and if the first computer is sending data to the second computer, then the third and the fourth computers will also receive an identical copy of that data. Hubs are usually used to set up a small Local Area Network (LAN), which may have on the order of 10 to 20 computers.
Switches
The aforementioned type of process, where the data is simply replicated onto every available port, quickly becomes inefficient for larger sized networks. For this reason, a larger sized LAN employs the usage of Switches instead of Hubs. A Switch is essentially a smart Hub, in that it limits the input and output of data to the two transacting computers.
Routers
Larger networks, such as Wide Area Networks (WANs), or the Internet for that matter, use progressively more sophisticated devices to transact data. At the core of these devices is the Router, which functions as a switch between networks.
The Cyclone performs irrespective of the connection mechanism, with one very important caveat: it needs to be set up with the appropriate network parameters for the underlying network architecture.

10.2

Network Parameters
A typical network becomes operational not after the physical connections have been established, but after network parameters in the form of IP (Internet Protocol) numbers have been assigned to the individual computers. An IP number is a unique string that consists of four numbers ranging between 0 and 255, separated by dots, e.g., 192.168.1.2. Every computer that is on a network needs to have a unique IP number. The computer uses this IP number to identify itself on the network, and also to address the recipient of its data.
Assignation of this IP number is sufficient information to transact data on a simple network connected by a hub. On a more complex network, however, routing information becomes important. The routing information consists of two more IP numbers. The first of these is called the Subnet Mask, and is used to determine whether or not the destination address resides on the same subnet (i.e., doesn't need to be forwarded to another network). The other IP number is the Gateway Address, which is the address of the computer that handles forwarding and receiving of packets to and from other networks.
Before first use, the Cyclone needs to be programmed with a unique IP number, the Subnet Mask IP number, and also the default Gateway's IP number. This can be done via the USB or the Serial port, and is described in greater detail in the "Configuring the Cyclone" section of this manual.

User Manual For Cyclone LC Programmers

121

10.3

Internet Protocol
Once the network has been established, and the IP numbers have been assigned, data can be transacted over a network with one of several protocols. By far the most prevalent protocol is the Transmission Control Protocol (TCP), which runs on top of the Internet Protocol in what is collectively known as the TCP/IP protocol. The TCP/IP protocol was developed by the Department of Defense to connect different computers from different vendors by a "network of networks," which has become what is known as the Internet today.
The primary purpose of the TCP/IP protocol was to prevent a complete network outage in the case of a nuclear attack, by automatically rerouting data traffic through the functioning part of the network. As such, the TCP/IP mechanism guaranteed delivery of data packets by introducing a system of acknowledgments and sequence numbers for the data packets. This mechanism, while good for transacting large amounts of data (such as email or file transfers), is unsuitable in the real-time type environment in which the Cyclone operates. Because the Cyclone needs to transact data as quickly as possible to the target, it takes advantage of TCP/IP's alternative, the UDP/IP protocol.
Unlike TCP/IP, the UDP/IP protocol is a connectionless, single-packet protocol that sends short data packets at the expense of not guaranteeing their delivery. This makes the UDP/IP protocol efficient in real-time applications such as broadcasting video over the Internet, where the occasional loss of a frame of data is not going to hamper the overall viewing experience. Left unmodified, the UDP/IP, with its lack of guarantees for packet delivery, would be unusable in an environment where the delivery of a single byte of data needs to be guaranteed. The Cyclone firmware adds mechanisms to the UDP/IP protocol, without affecting its underlying efficiency, to guarantee delivery of data packets.

10.4

Connecting The Cyclone Device
There are two methods for establishing a connection between a Cyclone and a PC with an Ethernet cable. The most basic method is to connect the Cyclone directly to a PC, via a cross-over Ethernet cable. However, the more common method is to place the Cyclone and the PC on the same network through a Hub.

10.4.1

Connecting the Cyclone to the PC over a network

The Cyclone was intended for use on a network of multiple computers (and other Cyclones). There are many possible network configurations, and to describe them all is beyond the scope of this document. However, most configurations are a modification of a basic theme, which is that of connecting one or more PCs through a Hub to one or more Cyclones.

In order to connect these devices to the Hub, you will need to use the provided straight-through Ethernet cable. The straight-through cable, which is the "standard" Ethernet cable, is used to connect devices of different types together, such as a PC to a Hub, or a Hub to a Cyclone.

At this point it once again becomes necessary to program the Cyclone with valid IP numbers, the process for which is described in greater detail in the following section. However, it is important for the Cyclone and the PCs to have matching Subnet and Gateway IP numbers, and for each to have a unique IP number on the network. An example of a setting for above is as follows:

IP Number

Gateway IP

Subnet Mask

PC1

192.168.100.1

192.168.100.3

255.255.255.0

PC2

192.168.100.2

192.168.100.3

255.255.255.0

CYCLONE 192.168.100.4

192.168.100.3

255.255.255.0

Gateway

192.168.100.3

192.168.100.3

255.255.255.0

It is important to briefly touch upon the underlying network architecture, which can be a 10Mb (Megabit), 100Mb, 10/100Mb, half-duplex, or a full-duplex connection. The details of the underlying network architecture are beyond the scope of this document, but it is sufficient to note that most modern network cards, as well as the Cyclone device, have the capability to configure themselves for the underlying network through the Auto-negotiation mechanism. Auto-negotiation is performed as soon as a network cable is connected to the device, and it sets the operating parameters of the

User Manual For Cyclone LC Programmers

122

10.4.2

device to match those of the network.

Connecting Cyclone-to-PC via an Ethernet cable

In order to connect the Cyclone to a PC directly via an Ethernet cable, you need to use what is known as a cross-over cable. A cross-over cable, which is not provided by PEmicro, is normally used to connect two similar devices such as a PC to a PC, or a Hub to a Hub. It is a cable that has its receive and transmit wires crossed over so that the similar devices can effectively communicate with one another.

With this configuration, it is still important to assign IP numbers to both the PC and the Cyclone device. Although at first glance it may not seem necessary to assign a Gateway address in this configuration, the Cyclone was designed to operate on a network of more than two computers, and therefore it needs to be programmed with a Gateway address.

Assuming the desktop's IP number to be 192.168.100.1, this is an example of the three IP numbers that would need to be programmed into the Cyclone:

IP Number

Gateway IP

Subnet Mask

PC

192.168.100.1

none

255.255.255.0

CYCLONE 192.168.100.2

192.168.100.1 255.255.255.0

For more information on programming these IP numbers into the Cyclone device, please see the following section.

10.5

Cyclone IP Setup Via LCD Menu
When the user is connecting the Cyclone via Ethernet, before the connection is established between the Cyclone and the network the menu's Home Screen will display the Cyclone's IP address as 0.0.0.0.
Once a connection has been established, the menu's Home Screen displays the Cyclone's IP address and connection setting (Static or Dynamic).
The Ethernet cable can either be attached at the start of Cyclone startup or connected after setup is complete. The connection with the network will be established when the cable is connected. If the Ethernet cable is disconnected after setup is complete, the user should be able to simply reconnect the cable to reestablish networking. However, depending on the setup of the DHCP server, if the Ethernet cable is left unplugged for a considerable time the IP address may expire and connection will have to be set up once again. This can be accomplished by restarting the Cyclone.

10.5.1

Configure Network Settings To configure network settings for the Cyclone, navigate to the following Menu location: Main Menu / Configure Cyclone Settings / Configure Network Settings
The following options will be available under Configure Network Settings: · Show Current IP Settings · Edit Static IP Settings · Enable/Disable Dynamic IP · Edit Cyclone Name

10.5.1.1 Show Current IP Settings Show Current IP Settings displays the current IP settings, including: · Current IP Mode · IP Number · Mask · Gateway

User Manual For Cyclone LC Programmers

123

· MAC Address
If you are in Static IP mode, these settings (excluding the MAC address) may be changed by tapping on them. In this case a tap will take you to the Edit menus. If you are in Dynamic IP mode, tapping will show a message that the Cyclone settings cannot be changed.
Dynamic vs. Static There are two schemes for assigning IP addresses. One is the Static IP addressing mode. This involves the user manually setting the IP address for every device on the network. In this case, it falls to the user to ensure the IPs assigned do not conflict and are within the boundaries of the network. The other is the Dynamic Host Configuration Protocol (DHCP). This involves setting up a separate server to manage the IP addresses. The server is given a list of valid IP addresses for the network. Using a predetermined set of rules, each new device that wishes to connect to the network is given an IP address by the server. This takes the task of managing the validity and uniqueness of IP addresses out of the user's hands and relegates it to the server. Cyclone LC programmers are capable of using either Static IP addressing or DHCP.
Note: The current IP settings may also be viewed/edited by navigating to:
Main Menu / Status / Show Current IP Settings
10.5.1.2 Edit Static IP Settings
This allows editing of IP, Mask, and Gateway in Static IP mode. In the edit dialogs, the user must enter a valid IP address to continue: Format
xxx.xxx.xxx.xxx Where:
0 <= xxx <= 255
10.5.1.3 Enable/Disable Dynamic IP
Opens a dialog to toggle the IP settings between Static and Dynamic. Once an option is selected a message is displayed indicating that the Cyclone must be reset for this option to take effect. The reset button on the front side of the Cyclone may be used.

10.6

Configuring Cyclone Network Settings using the Cyclone Control GUI
Before the Cyclone device transacts data on an Ethernet network, it will need to be configured with the relevant network parameters. This configuration can be done in the "Properties" tab of the Cyclone Control GUI.
To access the "Properties" tab, select the Cyclone from the drop-down list in the Cyclone Control GUI and click on "Connect". The "Properties" tab will be accessible once the Cyclone is open.

User Manual For Cyclone LC Programmers

124

Figure 10-1: Cyclone Control GUI: Properties Tab Selected From this tab, all Cyclone and Network properties can be accessed. Some of this properties are modifiable, including all the properties needed for network configuration. A property that can be edited will show three dots to the right of the property when you select it by clicking on its box. You can click on the three dots or double click on the property value to bring up the edit window.
Figure 10-2: Dots Displayed At Right When Property Selected

Figure 10-3: Edit Property Window
Once the "OK" button is pressed, the values of the property will be updated in the Cyclone and the value of the property in the Cyclone Control GUI will be refreshed showing the new value.

User Manual For Cyclone LC Programmers

125

11 SAP IMAGE ENCRYPTION
CYCLONE FX programmers and CYCLONE programmers with the ProCryption Security Activation License allow users to create RSA/AES encrypted programming images that use their own uniquely generated ImageKey. These encrypted images may only be used to program when on Cyclones that are also pre-configured with the same ImageKey. This keeps the user securely in control of both their IP and the programming process.

11.1

Overview
PEmicro uses a combination of industry-standard RSA and AES encryption technologies to encrypt images. When a programming image has been encrypted it requires two different asymmetric keys to be decrypted. The first is a user generated RSA encryption Key that was specified when the programming image was generated. The second is a native key which comes pre-installed in the Cyclone (and does not exist on the PC). This means that an encrypted image may (A) only be loaded onto a Cyclone which holds a copy of a user generated ImageKey, and (B) only be decrypted for programming while on a Cyclone which holds a copy of a user generated ImageKey. The Cyclone Control Suite (GUI, Console, SDK) allows the user to add and delete ImageKeys from Cyclones, much like programming images may be added or deleted. While many users will use only a single ImageKey to encrypt all of their images, Cyclones may have many different keys loaded.
Encrypted images are stored in the Cyclone in their encrypted form. If the ImageKey needed by a programming image is deleted from the Cyclone, the Cyclone loses the ability to load any images encrypted with that ImageKey or program any encrypted images encrypted with that ImageKey that are already loaded. Adding the ImageKey back into a Cyclone gives that Cyclone access to those stored encrypted images which require that ImageKey.
Encrypted images can safely be sent through electronic means to production facilities since they are unusable without a Cyclone which has been pre-loaded with the appropriate ImageKey.
ImageKeys on the PC are themselves partially encrypted so that certain pieces can only by used on a Cyclone. Even with this, they should be handled with care as they can be loaded into any Cyclone.

11.2

Encrypting/Decrypting a Programming Image
The Cyclone Image Creation Utility can generate ImageKeys that are used to encrypt SAP images. The steps that are necessary to generate ImageKeys, encrypt SAP images, provision Cyclones to decrypt, and program with encrypted SAP images are detailed in Section 6.1.10 - ProCryption Security Features.

11.3

What is Encrypted in an eSAP File, and How
An encrypted image (eSAP) contains three distinct sections: an informational header, a configuration section, and a stand alone programming (SAP) data section. The ImageKey encrypts each section in different ways to control access to each portion of the eSAP file.
The three eSAP sections are:
1) Informational Header
This section includes the description of the eSAP Image, its unique ID, the ID and name of the ImageKey used to encrypt it, and a checksum of the data. This section is not encrypted.
2) Configuration Section
This section contains a copy of the configuration settings used to generate the Image including which algorithm was used, power settings, clock settings, script files, and paths to the binary data files. No programming data from the user's data files is included in this section. This section is encrypted in such a way that if a user has the appropriate ImageKey on the PC, they may import the configuration information from an eSAP file into the Image Creation Utility. This is useful for seeing the settings used to generate an image, and, if the user has all of the data files needed, generate a new programming image file with the same

User Manual For Cyclone LC Programmers

126

configuration.
3) Stand Alone Programming (SAP) Data
This section contains all of the information a Cyclone needs to program a target as specified in the image creation process. This includes all programming data, algorithms, scripts, settings, etc. This section is encrypted with several keys, including the user generated asymmetric key as well as a native asymmetric key used by the Cyclone. Once encrypted, this section may not be decrypted except by the Cyclone during the programming process.

Figure 11-4: SAP Encryption
The end result of the encryption used to proceed the Stand Alone Programming Data is that the section can only by decrypted and used internally on a Cyclone which has a copy of the specified ImageKey provisioned within it. This eSAP section cannot be decrypted on a PC even with the ImageKey

11.4

Managing Encryption For Production Programming
The steps needed to encrypt programming images using the Cyclone Image Creation Utility are detailed in Section 6.1.10.1 - SAP Image Encryption. This section details how to successfully implement the use of these encrypted (eSAP) images into the production programming process.

11.4.1

Provisioning a Cyclone with an ImageKey
Cyclones that have been provisioned with an ImageKey are the only Cyclones that are able to load and program eSAP images encrypted with that ImageKey. When the user determines that one or more Cyclone programmer(s) will have access to an encrypted image, they need to load the ImageKey that was used to encrypt that image onto the Cyclone. This can be done with the Cyclone Control Suite GUI, Console, or SDK. The transfer of an ImageKey to a Cyclone using the Cyclone Control Suite is always secured by encrypting the ImageKey with an RSA public key specific to the Cyclone that it is connected to. Instructions on the use of these Control Suite options is explained in CHAPTER 8 - CYCLONE PROGRAMMER AUTOMATED CONTROL (CYCLONE CONTROL SUITE).
Figure 11-5 shows the Cyclone Control GUI with the Encrypted Keys tab selected.

User Manual For Cyclone LC Programmers

127

Figure 11-5: ImageKey Listing for Connected Cyclone
This tab displays any ImageKeys that are present on the Cyclone to which the user is connected. Note: If there is an encrypted SAP image on the Cyclone whose corresponding ImageKey has been
removed, the required ImageKey will be displayed as "Missing," along with its Name and ID.
To provision a Cyclone with an ImageKey, the user simply clicks the "Add Encryption Key" button and browses for the ImageKey that they wish to load onto the connected Cyclone.

Figure 11-6: Browse for ImageKey

User Manual For Cyclone LC Programmers

128

11.4.2

Removing ImageKeys From A Cyclone
It is also easy to remove an ImageKey from the connected Cyclone. The user selects the ImageKey that they wish to delete and hits the "Delete Encryption Key" button.

Figure 11-7: ImageKey Selected for Deletion
If the ImageKey that was selected for deletion is one that is required to decrypt one or more eSAP images that are on the connected Cyclone, a warning message will be displayed when the Delete button is pressed. The user may then cancel the deletion or confirm that they wish to proceed.

11.4.3

Figure 11-8: Warning: ImageKey Used By SAP Image on Connected Cyclone
Loading and Programming with Encrypted SAP Images From the user's perspective, loading an eSAP file with the Cyclone Image Creation Utility and programming with that eSAP file looks the same as loading/using a SAP file which is not encrypted (as long as the appropriate ImageKey exists on the Cyclone).

Figure 11-9: Load Encrypted Image (eSAP) onto Cyclone with Corresponding ImageKey When the user attempts to load an encrypted programming image onto a Cyclone, the Cyclone will

User Manual For Cyclone LC Programmers

129

refuse to load the image unless the appropriate ImageKey resides on the Cyclone. If the ImageKey is present, the Cyclone will load the eSAP File and automatically decrypt it using both the matching ImageKey and the Cyclone's internal decryption mechanism.
A user may create and use multiple ImageKeys and corresponding eSAP images on a single Cyclone.
The decryption process is transparent to the user when the Cyclone goes to program the target. The decrypted programming image appears as usual on the Cyclone menu screen. The user can now program devices using the unencrypted SAP Image.

11.4.4

Figure 11-10: Decryption Occurs Automatically For Programming
Encryption Status of SAP Images In the Images tab of the Cyclone Control Suite GUI the user can view the encryption status of SAP images that reside on the connected Cyclone. Figure 11-11 shows the Cyclone Control GUI with the Images tab selected.

Figure 11-11: SAP Image Listing for Connected Cyclone
The rightmost column, labeled Encryption, displays whether each SAP image is unencrypted ("None"), encrypted with the required ImageKey present ("Encrypted"), or encrypted but missing the ImageKey required to decrypt ("Encrypted No Key").

User Manual For Cyclone LC Programmers

130

11.5

Safer Production That's Easy To Implement
SAP Image encryption with Cyclone programmers is simple to implement and helps keep valuable intellectual property safe. Protected programming images can safely be sent electronically to remote production facilities. This adds much needed convenience and peace of mind to the production process.

User Manual For Cyclone LC Programmers

131

12
12.1

AUTOMATIC SERIAL NUMBER MECHANISM
When producing a microcontroller- or microprocessor-based product, it is often useful to program a unique serial number into the permanent memory (FLASH) of the product.
PEmicro offers a serial number mechanism to automate this process. Each time you issue a serialization command in the programming software, the current serial number is programmed at a specified address. In addition, the serial number is incremented to the next available serial number and saved for future serialized programming operations.
The Cyclone adopts this automatic serial number mechanism for its stand-alone operations. The user can create a Serial File using PEmicro's Serialize Utility and then include commands in the programming sequence of the programming image to implement that Serial File. If needed, adjustments can later be made to the serial number of a programming image.by using the Cyclone menu screen (see Section 5.2.2.3 - Serial Numbers).

Understanding Serialization

The automatic serial number mechanism supports serial numbers from 1 to 16 bytes in length. Each byte of a serial number ranges between a lower and an upper bound. This approach allows the individual bytes of the serial number to have distinct properties. Some of the forms these properties can take are:

Type

Lower Bound (hex) Upper Bound (hex)

Constant

Constant

Constant

Binary

00

FF

ASCII Printable

20

7E

ASCII Numeric

30

39

ASCII Upper Case Letter 41

5A

ASCII Lower Case Letter 61

7A

Other

XX

YY

12.2

Each serial number and its properties are stored in a separate file. Any file name can be used for the serial number file, however the extension .ser is normally appended because it makes it simpler to locate the file.
A utility called SERIALIZE has been developed to make it easy to create, visualize, edit, and maintain these serial number files.
Serialize Utility
The serialize utility allows the user to create a serial number file with a serial number that is anywhere from 1 to 16 bytes long. Each byte may be bounded as a full binary or as a Number, Constant, Alpha Uppercase, Alpha Lowercase, or ASCII printable character. The serial number file also has a field for a starting hex address that may range from 00000000 to FFFFFFFF. Serial numbers can be programmed in order or in reverse order.

User Manual For Cyclone LC Programmers

132

12.2.1

Figure 12-1: Serialize Main Screen
Startup And File Options
On startup, the Serialize program will automatically open the last file saved. If no file has been saved, it will default to blank.
· Reset Button - Lets you reset to a screen with only a single serial number byte defaulted to binary (00), Hex Address 00000000.
· Regenerate Button - Preserves serial number bytes and bounds but assigns a new Serial Number Unique ID
· Save Button, FileSave - Brings up a dialog to which is set to save to the current serial file configuration.
· FileSave As - Brings up a dialog to select any file · FileLoad - Brings up a dialog to select a previously saved file

User Manual For Cyclone LC Programmers

133

12.2.1.1 Reset
Instructs the program to start editing a NEW (as yet un-named) serial number file. It will throw away the information for any serial number currently being edited unless that information has been saved (Save Button). The new serial number is initialized with one (1) byte of binary.

12.2.1.2 Save
Pops up a Save dialog with the current serial number being edited into the file name and path as shown in the Serial Number File window. If a file name has not been provided, a dialog will pop up to allow the user select a file name. Save will save any setup information in the file Serialize.ini. This file will initialize the setup information the next time the program is started.

12.2.2

Serial Number File Displays the path and filename of the open Serial File, if saved.

12.2.3

Serial File Unique ID
Displays the unique ID associated with the Serial File. A unique ID is generated anytime a Serial File is created or modified. Multiple programming images are able to share the same serial numbers by referencing the same ID number (see Section 13.6 - Shared Serial Numbers). The user can click the "Regenerate" button to assign a new unique ID to the current Serial File.

12.2.4

Serial File Name To Display
The name that will appear in the JSON viewer, Cyclone menu, and in the Name field of the Cyclone Control GUI. A descriptive name can help to easily differentiate Serial Files.

12.2.5

Serial File Notes
Allows the user to save notes regarding the Serial File. These will appear in the JSON viewer when viewing the properties of the Serial File, see Section 13.3 - Serial File Properties.

12.2.6

Number of Bytes in Serial Number
The up and down arrows allow the user to add or delete bytes for the serial number, the maximum in hexadecimal = 0x10 (16 base ten), the minimum = 1.
· Up Arrow Click - Adds new bytes to the Serial Number. Each byte added appears as a new column in the serial number representation. Added bytes are input as Binary Bytes, i.e. the upper bound is FF and the lower bound is 00.
· Down Arrow Click - Deletes bytes from the right end of the Serial Number. Any previously entered byte properties are lost.

12.2.7

Starting HEX Address
Assigns the starting address (in hexadecimal) of the device memory where the serial number will be programmed.

12.2.8

Count Sequence
This window lets you test the serial number by counting up or down through the sequencing of the serial number. The serial number will roll over the upper bounds of the highest serial number back to the lower bounds of the serial number, and vice versa.
· Up Arrow Click - Counts the serial number up.
· Down Arrow Click - Counts the serial number down.

12.2.9

Serial Number Bytes as Hex
There is one display column for each byte in the serial number shown as printable ASCII characters. Non-printable ASCII characters are indicated by a blank gray box. · Up Arrow Click - Counts the serial number up.

User Manual For Cyclone LC Programmers

134

12.2.10 12.2.11 12.2.12 12.2.13

· Down Arrow Click - Counts the serial number down. · Click into the edit Box to enter any number within range. Values entered will be limited by the upper and lower bounds.
Hex Upper Bounds There is one display column for each upper bound of the byte in the serial number in hex. · Up Arrow Click - Increases the upper bound by one with a maximum of FF Hex. · Down Arrow Click - Decreases the upper bound by one with a minimum of the current serial number byte value. · Click into the edit Box to enter any number within range (from the Serial number value up to a maximum of Hex FF).
Hex Lower Bounds There is one display column for each byte of the lower bound of the serial number in hex. · Up Arrow Click - Increases the lower bound by one with a maximum of the current serial number byte value. · Down Arrow Click - Decreases the lower bound by one with a minimum of 00 Hex. · Click into the edit Box to enter any number within range (from the Serial number value to a minimum of 00 Hex).
Binary, Numeric, Constant, Alpha Upper, Alpha Lower, and Printable Checkboxes at the bottom will select properties to set for each serial number byte. Selections will be highlighted in yellow. The buttons below may be used to set the boundary type for the selected serial byte(s).
Byte Program Order The user can choose whether the serial number increments from left to right, or from right to left, in the Byte Program Order section.

12.3

Serial File Properties
Serial File properties are easy to access, as the generated serial file is stored in JSON format. This makes it simple for the user to save and parse the information. Note: Serial Files in JSON format are compatible with Cyclone LC firmware version 10.13 and later.
Users that wish to retrieve the original text serial number format can parse out the JSON file: object->pesettings-> serial_number_definition -> legacyv1encoding

12.3.1

Serial File Example
An example file is provided, Example.ser, located in the Image Creation folder of your installation directory. Below is a screen snapshot of the saved serial file as seen from a JSON viewer.

User Manual For Cyclone LC Programmers

135

12.4

Figure 12-2: Example Serial File In JSON Viewer
Serial Number Handling
The Cyclone LC firmware implements the automatic serial number mechanism (see Section 5.2.2.3 - Serial Numbers). The same serial number files are used with the Cyclone Image Creation Utility, and the same commands are used to specify the serial number file and initiate serial number programming and incrementation. The serial number data structure is saved in the SAP image. Once a "PS" command is carried out, a serial number is programmed into the target. Only after all operations have been completed successfully does the Cyclone firmware automatically increment the serial number and store it in the Cyclone's flash for internal images (or external CompactFlash for external SAP images).

The CS and PS commands are not present in the Cyclone Image Creation Utility until a valid programming algorithm is specified. To complement the Cyclone's usage in production environments, the Cyclone supports multiple serial number structures for each programming algorithm block. Each SAP image may contain multiple programming algorithms for every memory module it needs to program, and each programming algorithm block may contain multiple serial number structures. The SAP image sequence below illustrates this briefly:
CM algorithm_file_1 SS object_code_1 EM PM VC CS serial_file1.ser PS CS serial_file2.ser PS

User Manual For Cyclone LC Programmers

136

12.4.1

CS serial_file_3.ser PS CM algorithm_file_2 SS object_code_2 EM PM VC CS serial_file4.ser PS CS serial_file5.ser PS
Invoking A Serial File Via Command-Line The command to invoke the serial number file in PEmicro's interactive programming software is "CS Choose Serial File". The command to actually program the serial number to target and automatically increment the serial number afterward is "PS Program Serial Number". PEmicro's command line software uses the same commands in a command line fashion to invoke the serial number file, initiate its programming, and increment: CS serial_number_file.ser PS

12.5

Creating A SAP Image With Multiple Serial Numbers
In the example shown in Figure 13-3, a SAP image was created that will select and program two different serial numbers into different locations in memory as part of the programming sequence. The first serial number counts by two with starting address 0x00020000 and the second serial number counts by four with starting address 0x00021000.
As indicated by the programming sequence, first the Algorithm is selected, followed by the S19 file. The part is erased, and then the s19 is programmed into the device. Once this is done, the first serial file is selected and programmed, and then the second serial file. These same unique serial numbers may be used by other SAP images, and each program will increase the serial number by the designated count defined in the serial number file.

Figure 12-3: Cyclone Image Creation Utility: Serial Files In Programming Sequence

User Manual For Cyclone LC Programmers

137

12.6

Shared Serial Numbers
An important feature of the Serialize utility is that it automatically creates a Unique ID anytime a serial file is created or modified. This allows Stand-Alone Programming (SAP) images stored on a Cyclone to share serial numbers that reference the same unique serial number ID. There are several cases where this is very useful. The first is when a user may want to update their firmware for a product to a new version but needs the serial number to have persistence. The user may also have different products that need to be programmed with different firmware, but need to have those products draw from the same serialization sequence.
Note: Shared serial numbers require Cyclone LC firmware version 10.13 and later.

12.6.1

Example
This sections describes how a user might configure multiple SAP images on their Cyclone to share the same Serial File.

12.6.1.1 View and Edit SAP image Via Cyclone Control GUI
In Figure 13-4, the Cyclone Control GUI has been launched and is looking at the image contents of the Cyclone. In this case it shows that the Cyclone named Colossus contains four different SAP images.To view properties of a particular image properties, the user can simply right click on the desired image and select "View properties" which will pop up an image properties window. In this case it shows Image "Kinetis K64 PE S2 and Mac S4." The Image Unique ID is visible, as well as the two serial numbers and their respective Unique IDs. It also shows the next serial numbers (in ASCII representation) to be programmed upon launch: PE-000 and MAC-00, respectively.

User Manual For Cyclone LC Programmers

138

Figure 12-4: Cyclone Control GUI: Image Properties Window
Deleting the image will not delete the associated serial number as other images stored on the Cyclone may be using that same serial number. The serial number is tracked on the Cyclone by the imageuniqueid JSON property. If any image is added back onto the Cyclone with that same Serial Unique ID, it will continue to track with that same serial number at the latest count. So if a user has a new version of their firmware, they can create a new SAP image that uses the same serial number as the previous firmware (referenced by same serial unique ID) and the programming will continue the serial number sequence from the current serial number state since that serial file is stored on the Cyclone. Once a SAP image is loaded with a serial file, and it is selected as the current image on the Cyclone, it is possible to adjust the serial count. This is done by navigating through the following screens on the Cyclone.
Menu  Current Image Options  Serial Number
If the image has more than one serial number incorporated into the SAP image, select the Serial number which is to be modified. Otherwise just select `Modify Serial'.

User Manual For Cyclone LC Programmers

139

Figure 12-5: Cyclone Menu Selection It is possible to Decrease or Increase the Next Serial by -10, -1, +1, +10. This is often done to address issues in the production process, such as during initial setup.
Figure 12-6: Increase or Decrease Serial Number Note that the Cyclone Control GUI has the ability to show all the Serial Files stored on the Cyclone. This is done by opening a Cyclone, and then navigating to the Serial Files Tab, as shown in Figure 13-7. The Serial File tab has a Delete Button at the bottom which will remove the selected serial file from view and reset the tracking of the serial number to its original state. This does not actually delete the serial file. Once any programming is initiated using this `deleted' serial file, the serial file will reappear back in the list and program using the original serial number.

User Manual For Cyclone LC Programmers

140

Figure 12-7: Cyclone Control GUI: Serial Files Tab
12.6.1.2 Program SAP images With Shared Serialization
The Cyclone screen in Figure 13-8 shows two SAP images stored on the Cyclone: The first is `Waynes SAP Image Serialx2' and the second is `Garths SAP Image Serialx2'. They both use the same serial file named `PEserial K64 Count by 2' which has a unique ID ser-4FD596BF7DDD6470-5BDAE9E7 and the next serial number to be programmed (in ASCII) is PE-002. If we select Waynes SAP image we can see this current PE-002.

Figure 12-8: View Current Serial Number for "Wayne's SAP Image"
Once programmed is initiated, PE-002 is programmed into memory and the screen shows the next serial number to be programmed is which is PE-004.

User Manual For Cyclone LC Programmers

141

Figure 12-9: Serial Number Incremented for "Wayne's SAP Image" If the Garth's SAP Image is now selected on the Cyclone, it will show the next serial number to be programmed is PE-004 because it tracks the same serial number.
Figure 12-10: Serial Number Also Incremented for "Garth's SAP Image"

User Manual For Cyclone LC Programmers

142

13 CYCLONE LICENSE INSTALLATION
PEmicro's current-generation Cyclone LC programmers can have optional licenses installed into them: the SDHC Port Activation License, the ProCryption Security Activation License, and the Cyclone Control Suite Advanced Features License. Once a license is installed into the Cyclone, it will be available to the Cyclone even after it is reset and/or powered down. Having a license installed in the Cyclone is often advantageous since it moves with the Cyclone (if the Cyclone is moved from PC to PC).

13.1

How to Install Your License
Follow the steps below to install a license on your Cyclone LC programmer: 1. Make sure the Cyclone is powered and connected to the PC or PC's network (via USB, Ethernet, or Serial). 2. Open the Cyclone Control GUI and connect to the appropriate Cyclone. 3. Click the "License" tab in the Cyclone Control GUI.

Figure 13-1: Cyclone Control GUI: License Tab

User Manual For Cyclone LC Programmers

143

4. Click the "Add New License" button. Figure 13-2: Add New License Button

User Manual For Cyclone LC Programmers

144

5. A new window will pop-up and ask for you installation code. Add the Installation code for the license, which can be found on your invoice.

Figure 13-3: Add Installation Code For License

User Manual For Cyclone LC Programmers

145

6. Once you add your Installation code, the License Activation window will now tell you the several ways you can activate the license.

Figure 13-4: Activate License

User Manual For Cyclone LC Programmers

146

When the activation process is complete, your license is stored in the Cyclone and ready for use. Figure 13-5: License Installed

User Manual For Cyclone LC Programmers

147

14 TROUBLESHOOTING
This section answers some common questions that should help the user with various aspects of Cyclone LC operation.

14.1

My Cyclone Is Non-Responsive, Is There A Way To Re-Activate It?
It is possible that the issue is outdated firmware. In this case, you may wish to use bootloader mode to update the Cyclone firmware and then try to re-start the Cyclone.

14.1.1

What Is Bootloader Mode?
Bootloader Mode is a special running mode of the Cyclone Universal and Cyclone Universal FX in which only limited functionality of the Cyclone is allowed. In this mode, the Cyclone will allow communication to a PC via USB, Ethernet or serial ports. In Bootloader Mode the user can update the Cyclone firmware via the cyclone utilities.
The Bootloader screen will display the version of the bootloader, the version of the internal and external application, the name of the Cyclone and it's IP address.

14.1.2

When Is Bootloader Mode Used?
If the Cyclone ever becomes unresponsive, communication to the PC is not possible via USB, Ethernet, or Serial ports and if the cyclone fails to power on.

14.1.3

How Is Bootloader Mode Entered? You can force the Cyclone into bootloader mode with the following sequence, with the Cyclone powered: - Press the Reset button - Press the Start button - Release the Reset button - Tap the Cyclone LCD screen 3 times - Release the Start button

14.2

I Received A "SAP Image Needs To Be Updated" Error Using A Next-Gen Cyclone, How Do I Update?
The current PEmicro software that is available for all our Cyclones generates SAP images that are compatible with our newest generation of Cyclones.
However, customers who have generated SAP images using older versions of our Cyclone software with Cyclones such as the Cyclone PRO and Cyclone MAX, etc., will find that these SAP images will not work on the newer Cyclone LC and Cyclone FX programmers. Simply recreating these images for current generation Cyclones could potentially introduce errors and lose information about commands, settings, and configurations.
Therefore, we created the "SAP_Convert_Console.exe" which can be used to convert older generation SAP images into current generation SAP images. Once converted, an image will work not only on Cyclone LC and Cyclone FX programmers, but it will also remain compatible with the Cyclone for which it was originally created.

14.2.1

How Do I Use SAP_Convert_Console.exe?
SAP_Convert_Console.exe is a Windows command line utility and the software must be run through the Windows Command Prompt. The utility can be found in the same folder as the Cyclone's software install path.
The command line parameter syntax:

>SAP_Convert_Console [old_SAP_path] [new_SAP_path]

User Manual For Cyclone LC Programmers

148

14.3

Where:

[old_SAP_path] [new_SAP_path]

The relative or full path to the SAP file. Usually has the .SAP file extension.
Optional parameter where the user can specify a relative or full path to dump the output of the conversion. If path and file name matches the input, then the output file will replace the input file. If this parameter is not specified, the output will be dumped in the same path as the input file renamed with postfix "_2". For example if the input is myfile.SAP, then the output will be myfile_2.SAP and will not replace the original input file.

When Trying To Install The CYCLONE Software, A Popup WDREG Error Occurs Telling Me That There Are Open Devices Using WinDriver.

Figure 14-1: WDREG Error Message
The error is that the USB Driver (WinDriver) used by PEmicro devices and software is currently in use and can't be upgraded as such. The simple solution is to shut down any PEmicro software and also unplug any PEmicro Cyclone, Multilink, and OpenSDA devices. If the error pops back up upon Retry, or you are remote from the machine itself, go to the Windows Device Manager and right click on each Multilink, Cyclone, and OpenSDA device and select "Disable".

Figure 14-2: Disable Interfaces In Windows Device Manager
Upon clicking the Retry button in the installer, the drivers should now install and the devices will be automatically re-enabled.

User Manual For Cyclone LC Programmers

149

15 ERROR CODES
The Cyclone LC will indicate errors using the following codes. Please contact PEmicro if instructed or if you are unsure of the specific meaning of an error code.
Note: Some code numbers in the sequence are skipped, these are old codes that have been removed.

15.1

Debug Mode Communication Related Errors
$0001: No target device response. $0002: Invalid target device response. $0003: Programming operation canceled. $0004: Error while waiting for programming operation to complete. $0005: Error attempting to detect the communication speed. $0006: Error: Attempt to unsecure the device was unsuccessful. $0007: An error occurred while entering debug mode. $0008: Error entering debug mode. The device is secured. $0009: Error entering debug mode for verification. $000A: Error writing data to target. $000B: Error enabling or disabling device for programming. $000C: Error performing timing test. $000E: Error: Vendor hardware is not supported. $000F: Error generating VPP high voltage.

15.2

SAP Image Handling Related Errors
$0011: No image selected $0012: Error validating image CRC $0014: SAP image storage was not initialized $0015: SAP image transfer error, odd length is not allowed $0016: SAP image transfer error, invalid start address $0017: SAP image transfer error while writing to storage $0018: Error writing the serial number structure storage $0019: Error writing the menu structure storage $001A: Error erasing internal memory $001B: Image requires higher firmware version $001C: Image version is not supported. Please update firmware. $001D: Out of RAM memory. Try reset Cyclone. $001E: SAP image storage failure $001F: Old SAP image format, not supported. $0020: Programming image is not accessible. $0021: Another image is being loaded. Do not interrupt. $0022: Image already exists. $0023: invalid Image ID. Image ID exceeds the maximum number of images allowed. $0024: invalid Image ID. Image ID exceeds the total number of images available in the cyclone. $0025: The ImageKey needed for decryption is not found on the Cyclone. $0026: Image file can not be loaded.

User Manual For Cyclone LC Programmers

150

15.3 15.4 15.5 15.6 15.7
15.8

SAP Communication Handling Related Errors
$0031: System reset occurred $0032: System is busy with other operations. $0033: System is busy with too many inquiries. $0034: System has not finished initialization.
SAP Algorithm Header Operation Handling Related Errors
$0061: Undefined header operation $0062: Operation in algorithm header has failed.
SAP Operation Related Errors
$0081: SAP operation is not supported. $0082: Target type mismatch $0083: SAP operation canceled $0084: Running algorithm failure
SAP Blank Check Range and Module Related Errors
$1001: Blank Check is not supported by this algorithm. $1002: Blank Check algorithm was not found. $1003: Blank Check operation failed
SAP Erase Range and Module Related Errors
$2001: Erase error, algorithm not supported $2002: Erase error, algorithm not found $2003: Erase error, module failed or canceled $2004: Erase error, module failed, target is still secured $2005: Erase error, module not performed, data is preserved
SAP Program Byte, Word, and Module Related Errors
$3001: Program error, algorithm not supported $3002: Program error, algorithm not found $3003: Program operation failed or was canceled $3004: Program operation failed, write protected $3005: Program error, Data size exceeds the limit $300A: Error during reading data range, invalid data length $300B: Error during reading data range, invalid start address $300C: Error during reading data range, no target power $300D: Error during programming data range, invalid data length $300E: Error during programming data range, invalid start address $300F: Error during programming data range, no target power $3010: Error reported while running the custom test application (RT) on the target. $3011: Error displaying feature $3012: Error programming feature $3013: Error overlaying feature

User Manual For Cyclone LC Programmers

151

$3014: Error: Run Test Operation terminated $3015: Error: Run Test Operation over character limit 255 $3016: Error run test operation failed $3017: Error: unable to allocated memory during run test. $3018: Error: Dynamic operation failure. Algorithm is not loaded. Check image settings. $3040: Error: Program may cause the device to be secured permanently

15.9

SAP Verify Checksum Related Errors
$4001: Verify Checksum not supported $4002: VC failed, invalid algorithm was used $4003: VC operation failed or was canceled $4011: VV command not supported $4012: VV failed, invalid algorithm was used $4013: VV operation failed or was canceled

15.10 SAP Verify Range and Module Related Errors
$5003: Error during verifying module.

15.11

SAP User Function Related Errors
$6003: Error during user functions.

15.12

SAP Trim Related Errors
$7001: Program Trim operation is not supported $7003: No target response during a Program Trim operation $7004: Program Trim error. Trim value is not set $7007: Program Trim error. Trim value failed $7008: Trim error. Trim value read failed $7009: Trim value invalid, value is $00 or $FF $700A: Trim value is invalid. Trim value is already programmed.

15.13

Unrecoverable Fatal Errors
$8001: Fatal Error: please contact PEmicro. $8002: Fatal Error: please contact PEmicro. $8003: Fatal Error: please contact PEmicro. $8004: Fatal Error: please contact PEmicro. $8005: Fatal Error: please contact PEmicro. $8006: Fatal Error: please contact PEmicro. $8007: Fatal Error: please contact PEmicro. $8008: Fatal Error: please contact PEmicro. $8009: Fatal Error: please contact PEmicro. $800A: Fatal Error: please contact PEmicro. $800B: Fatal Error: please contact PEmicro. $800C: Fatal Error: please contact PEmicro. $800D: Fatal Error: please contact PEmicro.

User Manual For Cyclone LC Programmers

152

$800E: Fatal Error: please contact PEmicro. $800F: Fatal Error: please contact PEmicro. $8010: Fatal Error: please contact PEmicro. $8011: Fatal Error: please contact PEmicro. $8012: Fatal Error: please contact PEmicro. $8013: Fatal Error: please contact PEmicro. $8014: Fatal Error: please contact PEmicro. $8015: Fatal Error: please contact PEmicro. $8016: Fatal Error: please contact PEmicro. $8017: Fatal Error: please contact PEmicro. $8018: Fatal Error: please contact PEmicro. $8019: Fatal Error: please contact PEmicro. $801A: Fatal Error: please contact PEmicro. $801B: Fatal Error: please contact PEmicro. $801C: Fatal Error: please contact PEmicro. $8020: Fatal Error: please contact PEmicro. $8021: Fatal Error: please contact PEmicro. $8022: Fatal Error: please contact PEmicro. $8023: Fatal Error: please contact PEmicro. $8024: Fatal Error: please contact PEmicro. $8025: Fatal Error: please contact PEmicro.

15.14

Operation Security Related Errors
$9001: Error: Exceeds image specified Program Limit
$9002: Error: Exceeds image specified Error Limit
$9003: Error: Exceeds Image specified Date Range $9004: Error: This programming image has usage restrictions enabled. Cyclone ProCryption
Security is needed.
$9005: Error: This programming image has barcode enabled. Requires Cyclone FX hardware.
$9006: Error: This programming image has command RT Run Code in Test/Calibration Mode. Requires Cyclone FX hardware.
$9007: Error: This programming image has command DF Display Feature Data. Requires Cyclone FX hardware.
$9008: Error: This programming image has command PF Program Feature Data to Address.Requires Cyclone FX hardware.
$9009: Error: This programming image has command OF Overlay Feature Data over File Data. Requires Cyclone FX hardware.
$900A: Error: A Cyclone SDHC Port Activation License is needed before you can use an SD Card.

15.15

External Memory-Related Errors
$A001: Error writing to external memory card $A002: Error formatting the external memory card $A003: External memory card was disconnected during use $A004: External memory card has unsupported format $A005: External memory card has corrupted data

User Manual For Cyclone LC Programmers

153

$A006: Faulty external memory card. $A007: Failed during internal memory verification $A008: Failed during external memory card verification $A009: Error while reading external memory card for image pointer $A00A: Error: Read-only lock is enabled in the external memory card.

15.16

Serial Number Related Errors
$B001: Error erasing the serial number storage $B002: Error writing serial number $B003: Serial number is over the limit, up to 255 can be supported at a time $B004: Error loading Serial Number structure from reset $B005: Error during serial number structure update $B006: Error: Serial Number structure was not found. $B007: Error: Serial Number structure is invalid $B008: Error programming Serial Number to target. $B009: Error obtain Serial Number from storage.

15.17

Download Count Related Errors
$C001: Error erasing the download counts storage $C002: Error writing the download counts $C003: Download counts is over the limit, up to 255 can be supported at a time $C004: Error trying to convert the download counts structure

15.18

System Hardware/Firmware/Logic Recoverable Errors
$D001: Error: Firmware does not exist $D002: Error: Firmware update is not allowed $D003: Error: Firmware update has failed $D004: Error: There is a firmware mismatch during firmware update. $D005: Error: Voltage calibration failure. $D006: Error: Cannot either read or write disk

User Manual For Cyclone LC Programmers

154

16 OPTIONAL FEATURE ACTIVATIONS
PEmicro offers Cyclone LC users the flexibility to add many of the advanced security, automation/ control, and expandable memory features included with the Cyclone FX. These features can be added by purchasing and installing the appropriate activation license.

16.1

ProCryption Security
The ProCryption Security feature offers two extremely valuable security features:
1. RSA/AES encryption of programming images
Users create unique ImageKeys which are used to encrypt their programming images. SAP images encrypted in this way can only be loaded onto a Cyclone or programmed with a Cyclone if that Cyclone has been provisioned with the identical ImageKey.
2. The ability to restrict image programming by programming count or date range.
Programming restrictions on images are easily configured during the image creation process.
Together these security features help keep the user's valuable IP safe. The user should refer to CHAPTER 11 - SAP IMAGE ENCRYPTION for more information on encrypted programming images. Image restrictions are described in Section 6.1.10.2 - Image Restrictions.

16.2

Cyclone Control Suite Advanced Features

Cyclone LC programmers include a basic version of the Cyclone Control Suite. The Advanced Cyclone Control Suite Update enables additional features that allow the user to

· Add/Remove/Update multiple images in the Cyclone (via Console, SDK)

· Simultaneously (Gang) Control multiple Cyclones

- USB, Serial, or Ethernet

-

: USB, Ethernet

· Program (and Read) Dynamic Data in addition to fixed image data

This gives the user much more control and flexibility during the production process. The user should refer to Section 8.1 - Cyclone Control Suite - Overview for more information.

16.3

SDHC Port Activation
The SDHC Port Activation activates the SDHC port of the Cyclone LC. This allows the user expand the storage capacity of the Cyclone by loading images onto SDHC cards. SDHC cards can hold more and larger images than a Cyclone LC programmer can normally accommodate. The Cyclone display and management tools allow the user to easily distinguish between "internal" and "external" images. Section 6.2 - Managing Multiple SAP Images displays an example of how external images are differentiated.

User Manual For Cyclone LC Programmers

155

17 TECHNICAL INFORMATION
This section contains information about various physical, mechanical, electrical, etc. aspects of the Cyclone LC programmers, part # CYCLONE-LC-ARM and part # CYCLONE-LC-UNIV. The information applies to both Cyclone LC part numbers unless specified.

17.1

Life Expectancy

Start Button: 1 Million Press Rated

17.2

Electrical Specifications
Input Voltage: DC 5.9V - 12V, center positive Maximum Current: Up to 2A (0.6A typical) @ 6V
Up to 2A (0.4A typical) @ 12V Barrel size: 5.5mm outer diameter, 2.5 mm inner diameter

17.3

Mechanical Specifications
Dimensions: 8" L x 4" W x 1.25" H (20.3cm L x 10.2cm W x 3.2cm H) Weight: 12.7 oz (360 g)

17.4

Electromechanical Relays
Max Recommended Switched Voltage: DC 24V Max Recommended Switched Current: 1A Output Voltage To Debug Port (when configured for internal power): DC 2V-5V Max Current To Debug Port (when configured for internal power): 0.5 A

17.5

Debug Ports - CYCLONE-LC-ARM
Ports A, B: 0.05" (1.27 mm) Pitch Ports C,: 0.1" (2.54 mm) Pitch Characteristic Impedance: 50 ohms (all ports)

17.6

Debug Ports - CYCLONE-LC-UNIV
Ports A, B: 0.05" (1.27 mm) Pitch Ports C, D, E, F, G, H: 0.1" (2.54 mm) Pitch Characteristic Impedance: 50 ohms (all ports)

17.7

International Shipping
HTS Number: 8471500150 ECCN: EAR99

17.8

Compliances/Standards
ROHS Compliant CE Certified FCC Certified

More information on PEmicro's Cyclone programmers is available at: pemicro.com/cyclone.