Automatic and manual device self-test ... Control input (manual/auto reset) ... Automatic. - Manual. - Remote. • Rated control supply voltages. - 24 V AC/DC.
-- C ATA LO G Electronic relays and controls Offer overview and technical data · Interface relays and optocouplers · Time relays · Primary switch mode power supplies · Measuring and monitoring relays 2 ELECTRONIC RELAYS AND CONTROLSCATALOG -- ABB has the industry's most comprehensive range of time relays measuring and monitoring relays, interface relays and power supplies helping you to source all critical components from a single global supplier. Increase the reliability of process equipment with control devices that provide intelligent signals and smart adjustments that help you achieve maximum system availability. ELECTRONIC RELAYS AND CONTROLSCATALOG 3 -- Electronic relays and controls Table of contents 4 Overview 13 Time relays 73 Measuring and monitoring relays 247 Primary switch mode power supplies 361 Interface relays and optocouplers 458 Index 4 ELECTRONIC RELAYS AND CONTROLSCATALOG -- Interface relays and optocouplers A proven technology used worldwide Relays are universally applicable and are utilized in a diverse array of applications. They are a significant element in contemporary industrial processes and are used in applications where galvanic isolation, signal separation, voltage coupling and signal amplification are required. Optocouplers are predominantly used in applications where a high switching frequency is necessary. Furthermore, optocouplers do not contain any moving parts and are therefore bounce-free, immune to vibrations and possess a long electrical life. This wide selection of relays adheres to the highest global standards and satisfies the requirements for a diverse number of applications and needs. ABB offers a complete range of interface relays and optocouplers for increased flexibility and choice. This portfolio includes pluggable relays for easy interchangeability and optocouplers for an extended electrical life. The portfolio includes electromechanical relays and optocouplers - the electromechanical relays operate using an electromagnetic field, whereas optocouplers use light. Billions of relays operate and interface between control circuits and electrical loads Sensor 110 V AC 230 V AC Motor 380 V AC Interface relay Input 24 V DC Controller (PLC) Contactor 110 V AC 230 V AC 24 V DC out Interface relay ELECTRONIC RELAYS AND CONTROLSCATALOG 5 -- Time relays Have the perfect timing- everywhere Available in three different ranges to cover every application, the CT range time relays are used to provide reliable timing functions worldwide. In both industrial and building applications, the time relays of the CT range have proven their excellent functionality in daily use under the toughest conditions. Choose ABB as the partner for all your low voltage timing control needs to leverage our wide variety of product options. From economic to high-end solutions the range offers maximum value. Time relays are found everywhere, for example in air conditioning systems, heaters and fans in industrial and in residential buildings . On-delay, off-delay and a range of other functions cover all requirements. Shock and vibration resistant CT-S relays are perfect for use in rolling stock · Control panels · Pump controls · Star-delta motor starting · Movable equipment like cranes · Machine tools · Automatic doors · Car park barriers · Assembly machines · HVAC · Compressor controls · Transportation · Industrial refrigeration · Packaging machines · Backing ovens · Water and wastewater · Wind · Industrial cleaning processes 6 ELECTRONIC RELAYS AND CONTROLSCATALOG -- Primary switch mode power supplies Excellent reliability in harsh environments Available in four different ranges to cover every application requirement, ABB's CP range power supplies are used to power valuable assets worldwide. Emobility Emergency lighting LED lighting Communication Printing industry Food industry Escalators Packaging industry Elevators Choose ABB as your power supply partner and leverage our wide variety of product options. From economic to high-end solutions, the CP range offers maximum value. Their excellent reliability in daily use is well proven even under the toughest of conditions. ELECTRONIC RELAYS AND CONTROLSCATALOG 7 -- Measuring and monitoring relays Increase process availability and take action The relays inform users about abnormal conditions and allow them to take necessary corrective actions before severe and costly failures can occur. Measuring and monitoring relays monitor and detect operating conditions with regard to phase, current, voltage, frequency, temperature, liquid level or insulation faults. The relays inform users about abnormal conditions and allow them to take necessary corrective actions before severe and costly failures can occur. ABB offers the broadest range of measuring and monitoring relays in the industry - so you can source your critical components from a global supplier. Increase the reliability of your process equipment with controllers that deliver intelligent signals and settings to ensure maximum availability. Ensure continuous operation, engineer time savings and benefit from ABB's global support for measuring and monitoring relays. 8 ELECTRONIC RELAYS AND CONTROLSCATALOG -- Electronic relays and controls websites Your one-stop shop for product information On our web site you will also find the products in this catalog together with the current life cycle status, data sheets, certificates and tools. 3D data Life cycle information Coordination tables (SOC) E-configure Certificates new.abb.com/low-voltage/products/electronicrelays ELECTRONIC RELAYS AND CONTROLSCATALOG 9 Marketing material More brochures, catalogs and other tools about electronic relays and control products in rail applications, explosive atmospheres, as well as information about applications, safety products and motor protection and control products are available online. Online data sheets For detailed product information, use the order code to access the online data sheets as in the following example: new.abb.com/products/1SVR740110R3300 10 ELECTRONIC RELAYS AND CONTROLSCATALOG ELECTRONIC RELAYS AND CONTROLSCATALOG 11 -- ABB Connect Your digital assistant Connect to your electrification solutions with your digital assistant, access the latest news, and create your own digital workspace; search 'ABB Connect' on the Apple App Store, Google Play Store or Microsoft Store and download today. Find the latest product details Make your phone or tablet your workspace new.abb.com/low-voltage/service/abb-connect Tap and stay connected to all the latest information 12 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 13 -- Time relays Table of contents 15 Time relays for industrial applications 21 CT-C range 33 CT-S range 51 Time relays for building applications 54 CT-D range 65 Timing functions 14 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 15 -- Time relays for industrial applications Table of contents 16 Offer overview 17 Type selection 19 Applications 21 CT-C range 22 Benefits and advantages 23 Operating controls 24 Selection table 25 Ordering details 26 Technical data 30 Technical diagrams 33 CT-S range 34 Benefits and advantages 38 Selection table 39 Ordering details 42 Technical data 46 Technical diagrams 16 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- Time relays for industrial applications Offer overview CT-C: the compact range The CT-C range combines lower cost with higher value and performance by offering essential functions in a space-saving 17.5 mm housing. The range offers a choice of 11 devices, including single and multifunctional types, with timing functions that range from 0.05 seconds to 100 hours. Equipped with a wide voltage range, the CT-C range is suitable for a huge variety of applications worldwide. CT-S: the high-performance range The advanced CT-S range is ABB s universal range of electronic timers. It includes 22 single-function devices and 16 multifunction time relays, offering flexibility in operation with up to 13 functions. The devices feature seven or ten time ranges, adjustable from 0.05 seconds to 300 hours. Additionally, every device is available in two different connection technologies: familiar double-chamber cage connection terminals (screw terminals) and ABB's vibration-resistant Easy Connect technology (push-in terminals). ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 17 -- Time relays for industrial applications Type selection Timing function A ON-delay multi-functional CT-C CT-MFC, CT-MKC single-functional CT-ERC multi-functional single-functional CT-S CT-MVS, CT-MFS, CT-MBS, CT-ERS CT-WBS B OFF-delay AB ON- and OFF-delay CT-MFC, CT-MKC, CT-ARC CA Impulse-ON CT-MFC, CT-MKC CB Impulse-OFF CE DA DB DE ED H F Impulse-ON and OFF Flasher starting with ON Flasher staring with OFF Flasher starting with ON or OFF Pulse generator starting with ON or OFF Pulse former Star-delta change-over CT-MFC, CT-MKC, CT-ARC CT-MFC, CT-MKC CT-MFC, CT-MKC CT-MFC, CT-MKC CT-AHC CT-VWC CT-EBC CT-EBC CT-TGC CT-SDC, CT-SAC CT-MVS, CT-MFS, CT-MBS CT-APS, CT-AHS, CT-ARS CT-MVS, CT-MXS, CT-MFS, CT-MBS CT-MVS, CT-MFS, CT-MBS, CT-WBS CT-MVS, CT-MFS, CT-MBS CT-MXS CT-MFS, CT-MBS, CT-WBS CT-MFS, CT-MBS, CT-WBS CT-MVS CT-MXS CT-MVS, CT-MFS, CT-MBS CT-SDS FC A+ Star-delta change-over with impulse AC BC G further functions (depending on device) CT-MVS.2x, CT-MFS, CT-MBS CT-MVS, CT-MXS, CT-MFS, CT-MBS, CT-WBS A detailed explanation of the different timing functions can be found in the chapter "Timing functions". -- Synonyms Used expression 1 c/o contact 2 c/o contacts voltage-related volt-free Alternative expression(s) SPDT DPDT wet / non-floating dry / floating 18 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 19 -- Time relays for industrial applications Applications ABB offers a wide selection of time relays from economic to high-end to suit every application for businesses worldwide. ABB time relays provide simple, reliable and economical control solutions in all types of panel. They are typically used in industrial applications and OEM equipment, providing time-delayed switching to start a motor, control a load or manage a process. Remote control of time delays with a remote potentiometer. Cyclic switching of machinery, for example the weekly startup of a fan to prevent them sticking or the flushing of pipes to keep them clear. Lighting control, for example the delayed switching of multiple rows of lamps in production facilities or greenhouses. Time controlled start up or shut down of machinery equipment, for example the delayed switch off of conveyor belts or the successive shut down of a plant. Alarm triggering in case of fault detection, for example to allow the flashing of a lamp in industrial applications or rolling stock. Star-delta motor starting to reduce starting current with changeover delay to prevent interphase short-circuits. Have the perfect timing everywhere with ABB's time relays: · Control panels · Pump controls · Star-delta motor starting · Movable equipment e.g. cranes · Machine tools · Automatic doors · Car park barriers · Assembly machines · HVAC · Compressor controls · Transportation · Industrial refrigeration · Packaging machines · Backing ovens · Water and wastewater · Wind · Industrial cleaning processes 20 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 21 -- CT-C range Table of contents 22 Benefits and advantages 23 Operating controls 24 Selection table 25 Ordering details 26 Technical data 30 Technical diagrams 22 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-C range Benefits and advantages The CT-C range combines lower cost with higher value and performance by offering essential functions in a 17.5 mm housing, freeing up room in any control cabinet. The range includes 11 devices, offering both single and multifunctional types, with a time range from 0.05 seconds to 100 hours. Equipped with wide voltage ranges, CT-C time relays allow for use across a huge variety of applications worldwide. Space savings With a width of just 17.5 mm, the CT-C range is 22% smaller than standard industrial housings for time relays. Its reduced overall footprint saves space in control cabinets. For more flexibility both 1 c/o and 2 c/o output versions are offered in the compact housing. Cost effective solution The CT-C range is an economical range that combines lower cost with higher value and performance. It suits basic applications where a time relay is needed, while offering improved functionality in each device. Optimized logistics By combining more functions into each device, the CT-C range makes it possible to reduce stock by up to 75% compared to other ranges. All devices in the CT-C range offer a wide supply voltage range as well as a wide time setting range from 0.05 seconds to 100 hours. This significantly reduces order code variance, making the range more compact with just 11 order codes covering every requirement. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 23 -- CT-C range Operating controls Connection terminals Wide terminal spacing makes wiring connections easier: 2 x 1.5 mm2 (2 x 16 AWG) with wire end ferrules or 2 x 2.5 mm2 (2 x 14 AWG) without ferrules. Width 17.5 mm With a width of just 17.5mm, CT-C time relays are ideal for installations with limited space. Control input to start timing Preselection of the time range Direct reading scales Direct setting of the time delay without any additional calculation provides accurate time delay adjustment. Selection of the timing function A ON-delay B OFF-delay with aux. voltage CA Impulse-ON CB DA Impulse-OFF with aux. voltage Flasher starting with ON DB Flasher starting with OFF H Pulse former Fine adjustment of the time delay LEDs for status indication All actual operational states are displayed by front-facing LEDs, simplifying commissioning and troubleshooting. · U - green LED: V control supply voltage applied / W timing · R, R1, R2 - yellow LED: V output relay energized 24 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-C range Selection table Order number 1SVR508010R1300 1SVR508020R0000 1SVR508020R1100 1SVR508120R0000 1SVR508100R0000 1SVR508100R0100 1SVR508110R0000 1SVR508110R0100 1SVR508130R0000 1SVR508150R0000 1SVR508160R0000 1SVR508160R0100 1SVR508210R0100 1SVR508211R0100 Type CT-MKC.31 CT-MFC.12 CT-MFC.21 CT-ARC.12 CT-ERC.12 CT-ERC.22 CT-AHC.12 CT-AHC.22 CT-VWC.12 CT-EBC.12 CT-TGC.12 CT-TGC.22 CT-SAC.22 CT-SDC.22 Timing function ON-delay AJJJ JJ OFF-delay with aux. voltage BJJJ JJ OFF-delay w/o aux. voltage B J Impulse-ON CA J J J J Impulse-OFF with aux. voltage CB J J J Impulse-OFF w/o aux. voltage CB J Flasher starting with ON DA J J J J Flasher starting with OFF DB J J J J Pulse generator starting with ON or OFF ED JJ Pulse former HJJJ Star-delta change-over F JJ Features Control input, voltage-related triggering JJ JJ JJ Time range 0.05 s - 100 h 0.05 s - 10 min JJJ JJJJJJ2 2 J JJ Supply voltage 12-240 V AC/DC 24-48 V DC 24-240 V AC JJ J JJJJJJJJJJJ J JJJJJJJJJJJ Output Solid state c/o contact J 12112121112 n/o contact 22 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 25 -- CT-C range Ordering details CT-MFC.12 CT-ERC.22 M Control input with voltage-related triggering - No triggering 2CDC251029V0018 2CDC251030V0018 Description The CT-C range combines lower cost with higher value and performance in a slim 17.5 mm-wide housing. All relays have a wide time setting range from 0.05 seconds up to 100 hours. Combined with a wide voltage range they are the perfect choice for applications worldwide. -- Ordering details Timing function Rated control Time supply ranges voltage Control Output Type input Order code Multi1) 12-240 V AC/DC 7 (0.05 s - M 100 h) Multi1) 24-240 V AC M 24-48 V DC Multi1) 12-240 V M AC/DC Dual2) 24-240 V AC 7 (0.05 s - 24-48 V DC 10 min) ON-delay 24-240 V AC 7 (0.05 s - 24-48 V DC 100 h) - Solid state 1 c/o CT-MKC.31 1SVR508010R1300 CT-MFC.12 1SVR508020R0000 2 c/o CT-MFC.21 1SVR508020R1100 1 c/o CT-ARC.12 1SVR508120R0000 1 c/o CT-ERC.12 1SVR508100R0000 2 c/o CT-ERC.22 1SVR508100R0100 OFF-delay M 1 c/o CT-AHC.12 1SVR508110R0000 M 2 c/o CT-AHC.22 1SVR508110R0100 ImpulseON Flasher3) - 1 c/o CT-VWC.12 1SVR508130R0000 - CT-EBC.12 1SVR508150R0000 Pulse generator 2×7 (0.05 s - M 100 h) M CT-TGC.124) 1SVR508160R0000 2 c/o CT-TGC.224) 1SVR508160R0100 Star-delta changeover 4 (0.05 s - 10 min) - 2 n/o CT-SDC.225) 1SVR508211R0100 CT-SAC.226) 1SVR508210R0100 Weight (1 pc) kg (lb) 0.060 (0.132) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.060 (0.132) 0.060 (0.132) 0.065 (0.143) 0.065 (0.143) 1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former 2) OFF-delay without aux. voltage (True OFF-delay), True Impulse-OFF 3) Flasher starting with ON, Flasher starting with OFF 4) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h 5) Transition time 50 ms fixed 6) Transition time adjustable 26 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-C range Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated CT-C with 1 c/o contact CT-C with 2 c/o contacts CT-MFC.21 Input circuit - Supply circuit Rated control supply voltage Us 24-240 V AC / 24-48 V DC 12-240 V AC/DC Rated control supply voltage US tolerance -15...+10 % Rated frequency DC or 50/60 Hz Frequency range AC 47-63 Hz Typical power consumption max. 3.5 VA Power failure buffering time min. 20 ms Release voltage > 10 % of the minimum rated control supply voltage Us Input circuit - Control circuit Control input, control function A1-Y1/B1 start timing external Kind of triggering voltage-related triggering Resistance to reverse polarity yes Parallel load / polarized yes / yes Maximum cable length to the control inputs 50 m 100 pF/m Minimum control pulse length 20 ms Control voltage potential see rated control supply voltage Timing circuit Time ranges 7 time ranges 0.05 s - 100 h 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min 5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h 4 time ranges 0.05 s - 10 min (CT-SDC, CT-SAC) 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min Recovery time < 50 ms Accuracy within the rated control supply voltage tolerance it < 0.005 % / V Accuracy within the temperature range it < 0.06 % / °C Repeat accuracy (constant parameters) it < ± 0.5 % Setting accuracy of time delay ± 10% of full-scale value Star-delta transition time CT-SDC / CT-SAC fixed 50 ms / adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms Star-delta transition time tolerance CT-SDC / CT-SAC ±3 ms Indication of operational states Control supply voltage / timing U: green LED V: control supply voltage applied W: timing Relay energized R, R1, R2: yellow LED V: output relay energized Operating elements and controls Adjustment of the time range Fine adjustment of the time value Preselection of the timing function at multifunction devices Adjustment of the transition time front-face rotary switch, direct reading scales front-face potentiometer front-face rotary switch, direct reading scales CT-SAC front-face potentiometer Note Technical information for CT-ARC.12 and CT-MKC.31 on request. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 27 -- CT-C range Technical data CT-C with 1 c/o contact CT-C with 2 c/o contacts CT-MFC.21 Output circuit Kind of output 15-16/18 Relay, 1 c/o contact - 15-16/18; 25-26/28 - Relay, 2 c/o contacts 17-18; 17-28 Relay, 2 n/o contacts (CT-SDC, CT-SAC) Contact material AgNi alloy, Cd free Rated operational voltage Ue 250 V Minimum switching voltage / minimum switching current 12 V / 100 mA Maximum switching voltage / maximum switching current 250 V AC / 6 A 250 V AC / 5 A Rated operational current Ie AC-12 (resistive) at 230 V 4 A 4 A AC-15 (inductive) at 230 V 3 A 3 A n/o: 3 A n/c: 0.75 A DC-12 (resistive) at 24 V 4 A 4 A DC-13 (inductive) at 24 V 2 A 2 A 1 A AC rating (UL 508) utilization category (Control Circuit Rating Code) B 300 n/o: B 300 n/c: C 300 max. rated operational voltage 300 V AC maximum continuous thermal current at B300 5 A n/o: 5 A maximum continuous thermal current at C300 - n/c: 2.5 A max. making/breaking apparent power at B300 3600 VA / 360 VA n/o: 3600/360 VA max. making/breaking apparent power at C300 - n/c: 1800/180 VA Mechanical lifetime 30 x 106 switching cycles Electrical lifetime 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting 6 A fast-acting General data Mean time between failures (MTBF) on request Duty cycle 100% Dimensions see `Dimensional drawings' Mounting DIN rail (IEC/EN 60715), snap-mounting without any tool Mounting position any Minimum distance to other units horizontal / vertical no / no Degree of protection housing / terminals IP50 / IP20 Electrical connection Connecting capacity fine-stranded with(out) 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) wire and ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG) rigid 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) 1 x 0.5-4 mm2 (1 x 20-12 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.5-0.8 Nm (4.43-7.08 lb.in) Environmental data Ambient temperature range operation / storage -20 ... +60 °C / -40 ... +85 °C Climatic class EC/EN 60068-2-30 3K3 Relative humidity range 25-85% Vibration, sinusoidal IEC/EN 60068-2-6 20 m/s²; 10 cycles, 10...150...10 Hz Shock (half-sine) IEC/EN 60068-2-27 150 m/s2, 11 ms Note Technical information for CT-ARC.12 and CT-MKC.31 on request. 28 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-C range Technical data CT-C with 1 c/o contact Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Power-frequency withstand voltage test(test voltage) input circuit / output circuit 300 V output circuit 1 / output circuit 2 not available between all isolated circuits 4 kV; 1.2/50 µs between all isolated circuits 2.5 kV; 50 Hz; 60 s Basic insulation (IEC/EN 61140) input circuit / output circuit 300 V Protective separation (IEC/EN 61140, EN 50178) input circuit / output circuit 250 V Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 61812-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V / m) electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz) surge IEC/EN 61000-4-5 Level 4 (2 kV L-L) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 (10 V) Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B CT-C with 2 c/o contacts 300 V CT-MFC.21 300 V ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 29 -- CT-C range Technical diagrams -- Example of application - Star-delta changeover L1 F3 95 F2 96 S1 21 0 22 S2 13 53 I K2 14 54 17 K1T 18 17 13 13 K2 K1 28 14 14 22 K3 21 22 K1 21 K1T N A1 A1 A1 A1 K1 K3 K2 A2 A2 A2 A2 Y i N Control circuit diagram L1 L2 L3 135 -F1 246 135 -K2 2 4 6 135 135 -K3 2 4 6 -K1 2 4 6 154 -F2 326 97 95 98 96 -M1 W1 W2 V1 M V2 U1 3 ~ U2 Power circuit diagram 2CDC252128F0006 2CDC 252 128 F0b06 2CDC253009F0012 2CDC 253 009 F0012 30 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-C range Technical diagrams -- Connection diagrams CT-MFC.21 A1 15 25 Y1/ B1 A1 15 25 CT-MFC.12 A1 15 Y1/ B1 A1 Y1/B1 15 A CT-ERC.22 A1 15 25 A1 15 25 A CT-ERC.12 A1 15 A1 15 2CDC252113F0b06 2CDC 252 113 F0b06 2CDC252114F0b06 2CDC 252 114 F0b06 2CDC252115F0b06 2CDC 252 115 F0b06 2CDC252177F0b05 2CDC 252 177 F0b05 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 A1-A2 A1-Y1/B1 15-16/18 25-26/28 Supply: 12-240 V AC/DC Control input 1st c/o contact 2nd c/o contact A2 16 18 18 16 A2 A1-A2 A1-Y1/B1 15-16/18 Supply: 24-48 V DC or 24-240 V AC Control input 1st c/o contact A2 16 18 26 28 18 16 28 26 A2 A1-A2 15-16/18 25-26/28 Supply: 24-48 V DC or 24-240 V AC 1st c/o contact 2nd c/o contact A2 16 18 18 16 A2 A1-A2 15-16/18 Supply: 24-48 V DC or 24-240 V AC 1st c/o contact 2CDC252116F0b06 2CDC 252 116 F0b06 2CDC252117F0b06 2CDC 252 117 F0b06 2CDC252179F0b05 2CDC 252 179 F0b05 B CT-AHC.22 A1 15 25 Y1/ B1 A1 15 25 B CT-AHC.12 A1 15 Y1/ B1 A1 Y1/B1 15 CA CT-VWC.12 A1 15 A1 15 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 A2 16 18 18 16 A2 A2 16 18 18 16 A2 A1-A2 A1-Y1/B1 15-16/18 25-26/28 Supply: 24-48 V DC or 24240 V AC Control input 1st c/o contact 2nd c/o contact A1-A2 A1-Y1/B1 15-16/18 Supply: 24-48 V DC or 24240 V AC Control input 1st c/o contact A1-A2 15-16/18 Supply: 24-48 V DC or 24240 V AC 1st c/o contact 2CDC252118F0b06 2CDC 252 118 F0b06 2CDC252119F0b06 2CDC 252 119 F0b06 2CDC 252160F0b06 2CDC 252 160 F0b06 2CDC 252160F0b06 2CDC 252 160 F0b06 ED CT-TGC.22 A1 15 25 Y1/ B1 A1 15 25 ED CT-TGC.12 A1 15 Y1/ B1 A1 Y1/B1 15 F CT-SDC.22 A1 17 A1 17 F CT-SAC.22 A1 17 A1 17 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 A1-A2 A1-Y1/B1 15-16/18 25-26/28 Supply: 24-48 V DC or 24-240 V AC Control input 1st c/o contact 2nd c/o contact A2 16 18 18 16 A2 A2 18 28 28 18 A2 A2 18 28 28 18 A2 A1-A2 A1-Y1/B1 15-16/18 Supply: 24-48 V DC or 24240 V AC Control input 1st c/o contact A1-A2 17-18 17-28 Supply: 24-48 V DC or 24-240 V AC 1st n/o contact (star contactor) 2nd n/o contact (delta contactor) A1-A2 17-18 17-28 Supply: 24-48 V DC or 24-240 V AC 1st n/o contact (star contactor) 2nd n/o contact (delta contactor) ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 31 -- CT-C range Technical diagrams 2CDC252124F0206 2CDC 252 124 F0206 2CDC 252 148 F0206 -- Load limit curves AC load (resistive) CT-C.1x resistive load AC voltage [V] CT-C.2x AC current [A] 22CCDDC2C522502103F1032F108218 DC voltage [V] DC load (resistive) CT-C.1x resistive load CT-C.2x DC current [A] 2CDC252150F0206 2CDC 252 150 F0206 Derating factor F -- Derating factor F for inductive AC load 1.0 0.9 0.8 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos -- Contact lifetime Switching cycles 2CDC 252 150 F0206 resistive load resistive load 250 V resistive load 22CCDDCC25225021031F30F2108218 DC voltage [V] AC voltage [V] 2CDC252150F0206 AC current [A] -- Wiring notes for devices with control input A parallel load to the control input is possible L(+) A1 Y1/B1 DC current [A] -- Dimensional drawings in mm and inches 0.69" 17,5 58 2.28" 0.2" 5 43,4 1.71" A2 N(-) CT-C devices with 1 c/o contact or 2 n/o contacts Switching current [A] 0.69" 17,5 58 2.28" 0.2" 5 43,4 1.71" CT-C devices with 2 c/o contacts 2CDC252148F0206 2CDC252102F0006 2CDC 252 102 F0b06 70 2.76" 45 1.77" 2 2CCDDCC2255212311F301b0F60b06 80 3.15" 45 1.77" 2CCDDCC2522512301F3000F006b06 32 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 33 -- CT-S range Table of contents 34 Benefits and advantages 38 Selection table 39 Ordering details - multifunctional devices 40 Ordering details - singlefunctional devices 41 Ordering details - Accessories 42 Technical data 46 Technical diagrams 34 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Benefits and advantages The advanced CT-S range includes 22 single-function devices and 16 multifunction timers with up to 13 functions. The devices feature seven or ten time ranges, which are adjustable from 0.05 seconds to 300 hours. Every device is available in two different connection technologies: double-chamber cage connection terminals or ABB's vibration-resistant Push-in Technology. Improve installation efficiency The CT-S range allows simple tool free mounting and demounting on the DIN rail. Thanks to the easy connect and the double-chamber cage connection technology simplified wiring with or without wire end ferrules is no problem. Both allow simple and easy installation, even in case of different cable diameters. Reliable in harsh conditions The CT-S range's extended features make it especially suited for harsh environments. The housing material has the highest UL fire protection classification. All functions are available with Push-in terminals, making operations in environments with high vibrations possible without retightening. Additionally, the CT-S range offers devices with an extended temperature range, running operations in temperatures as low as -40 °C effortlessly. Specific types are tested according to the latest rail industry standards, making them a perfect solution for rolling stock and other rail applications Global availability Every device in the CT-S range is designed to provide a wide supply voltage range, making global differences irrelevant. Additionally, the CT-S range meets a broad range of standards and requirements. Together with ABB's global support and sales network, using CT-S gives customers the confidence of worldwide sourcing no matter where they build, install or operate their equipment. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 35 -- CT-S range Operating controls Control input Starts and pauses timing. Preselection of time range Direct assignment of the pre-selected time range to the fine adjustment potentiometer scale by multicolor scales Fine adjustment of the time delay Selection of the timing function Connection terminals Screw or push-in connection available. Remote potentiometer connection possible 2nd contact selectable as an instantaneous contact LEDs for status indication All actual operational states are displayed by front-face LEDs, thus simplifying commissioning and troubleshooting. · U/T - green LED: V control supply voltage applied / W timing · R, R1, R2 - yellow LED: V Output relay energized Integrated marker label Integrated marker labels allow the product to be marked quickly and simply. No additional marker labels are required. 36 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Benefits and advantages Easy Connect Technology Tool-free wiring and excellent vibration resistance. Easy Connect (Push-in terminals) provide connection of wires up to 2 x 0.5 - 1.5 mm² (2 x 20 -16 AWG), rigid or fine-strand with or without wire end ferrules. The extended type designators for products with push-in terminals are indicated by a P following the extended type designator e.g. CT-xxS.xxP. 2CDC253026F0011 -- 01 Tool-free mounting of wires -- 02 Wiring of double-cage chamber connection terminals with screw driver 2CDC253025F0011 Double-chamber cage connection terminals According to IEC/EN 60947-1 double-chamber cage connection terminals provide connection of wires up to 2 x 0.5-2.5 mm² (2 x 20-14 AWG) rigid or fine-strand, with or without wire end ferrules. Thanks to the technology, using different cable diameters in one terminal is easy and simple to install. Potential distribution does not require additional terminals. The extended type designators for products with double-chamber cage connection terminals (screw terminals) are indicated by an S following the extended type designator, e.g. CT-xxS.xxS. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 37 -- CT-S range Made for the most extreme conditions Selected products of the CT-S range comply to the latest rail standards like EN50155. Designed for harsh environments, not only are standard screw type terminals offered push-in terminals with excellent vibration resistance are also available. Perfect for use in rolling stock. Conductor car · In the event of the press switch not switching off the auxiliary release pumps of the breaking system, a delayed switch off is triggered by the time relays · While switching between hold-on and start-up coil on the main switch, a time relay can prolong the pulse · The reliable and safe functionality of the compressor is essential for trains Passenger cars · The control of air flow and interior lighting is controlled by time relays. A time interval can trigger a delayed start and finish for the air circulation as well as turning on or off the lights inside the cabin · The advanced CT-S range of time relays from ABB is designed to fulfill all necessary requirements for rail applications -- Electronic relays for railway solutions brochure For more information about time relays in rolling stock applications visit: new.abb.com/low-voltage/products/electronicrelays or scan the QR code 38 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Selection table CT-SDS.23l 1SVR70211R2300 CT-SDS.22l 1SVR70210R3300 CT-ARS.21l 1SVR70120R3300 CT-ARS.11l 1SVR70120R3100 CT-AHS.22l 1SVR70110R3300 CT-APS.12l 1SVR70180R3100 CT-APS.22l 1SVR70180R3300 CT-APS.21l 1SVR70180R0300 CT-ERS.12l 1SVR70100R3100 CT-ERS.22l 1SVR70100R3300 CT-ERS.21l 1SVR70100R0300 CT-WBS.22l 1SVR70040R3300 CT-MBS.22l 1SVR70010R3200 CT-MFS.21l 1SVR70010R0200 CT-MXS.22l 1SVR70030R3300 CT-MVS.12l 1SVR70020R3100 CT-MVS.23l 1SVR70021R2300 CT-MVS.22l 1SVR70020R3300 CT-MVS.21l 1SVR70020R0200 Order number* Type* -- Order number and type All devices are available either with push-in terminals (P-type) or doublechamber cage connection terminals (S-type). Terminal Push-in Screw Type l = P l = S Order number = 4 = 3 Timing function ON-delay ON-delay, accumulative OFF-delay w. aux. voltage OFF-delay w. aux. voltage, accumulative OFF-delay w/o aux. voltage ON- and OFF-delay, symmetrical ON- and OFF-delay, symmetrical, accumulative ON- and OFF-delay, asymmetrical ON/OFF function Impulse-ON Impulse-ON, accumulative Impulse-OFF w. aux. voltage Impulse-OFF w. aux. voltage, accumulative Impulse-ON and OFF Fixed impulse with adjustable time delay Adjustable impulse with fixed time delay Flasher starting with ON Flasher with reset, starting with ON Flasher starting with OFF Flasher with reset, starting with OFF Flasher starting with ON or OFF Pulse generator starting with ON or OFF Single pulse generator Pulse former Star-delta change-over Star-delta change-over with impulse AJJJJ JJJJJJ A(+) J J J J J BJJJJ JJ JJJJ B J B JJ AB J J J J J J AB J AB J GJJJJJJJJ CA J J J J J J J CA J CB J J J J J J CB J CE J AC J AC J DA JJJ DA JJ DB JJJ DB JJ DE J J J J ED J EC J HJJJJ JJ F JJ FC J J J JJ Features Control input, voltage-related triggering Control input, volt-free triggering Remote potentiometer connection 2nd c/o contact selectable as instantaneous contact Extended temperature range (-40...+60 °C) Time range JJJJJ 21 J 2 JJ J JJ J JJ JJJ J J 0.05 s - 10 min 0.05 s - 300 h JJJJ JJJJ 2 JJJJJJJJJJ Supply voltage 24-48 V DC 24-240 V AC 24-240 V AC/DC 380-440 V AC J JJ JJ JJ JJJ J J JJ JJ JJ JJJ J J JJJ JJ J J Output c/o contact 22212222221221212 n/o contact 22 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 39 -- CT-S range Ordering details - multifunctional devices CT-MVS.21P CT-MBS.22P M Control input with voltage-related triggering m Control input with volt-free triggering m / m Two control inputs with volt-free triggering - No triggering 2CDC 251 023 V0011 2CDC 251 024 V0011 Description The high-performance CT-S range is ideally suited for universal use and is available with two different connection technologies: · Double-chamber cage connection terminals (Screw terminals) · Easy Connect Technology (Push-in terminals) -- Ordering details Timing Rated control Time function 5) supply ranges voltage Control Output Type input Order code Multi 24- 240 V AC/DC 10 (0.05 s - M 300 h) 2 c/o CT-MVS.21S 1) 2) 3) 1SVR730020R0200 CT-MVS.21P 1) 2) 3) 1SVR740020R0200 24-48 V DC, 24-240 V AC CT-MVS.22S CT-MVS.22P 1SVR730020R3300 1SVR740020R3300 380-440 V AC CT-MVS.23S 1SVR730021R2300 CT-MVS.23P 1SVR740021R2300 Multi 24-48 V DC, 10 (0.05 s - M 24-240 V AC 300 h) 1 c/o CT-MVS.12S CT-MVS.12P 1SVR730020R3100 1SVR740020R3100 Multi 24-48 V DC, 2×10 (0.05 s M 24-240 V AC - 300 h) 2 c/o CT- MXS.22S 4) 1SVR730030R3300 CT-MXS.22P 4) 1SVR740030R3300 Multi 24- 240 V AC/DC 10 (0.05 s - n / n 300 h) 2 c/o CT-MFS.21S 1) 2) 3) 1SVR730010R0200 CT-MFS.21P 1) 2) 3) 1SVR740010R0200 24-48 V DC, 10 (0.05 s - n 24-240 V AC 300 h) 2 c/o CT-MBS.22S 2) 3) 1SVR730010R3200 CT-MBS.22P 2) 3) 1SVR740010R3200 Multi 24-48 V DC, 10 (0.05 s - 24-240 V AC 300 h) 2 c/o CT-WBS.22S CT-WBS.22P 1SVR730040R3300 1SVR740040R3300 1) Extended temperature range -40 °C 2) Remote potentiometer connection 3) 2nd c/o contact selectable as instantaneous contact 4) 2 remote potentiometer connections 5) See selection table on previous page S: Screw connection P: Push-in / easy connect Weight (1 pc) kg (lb) 0.148 (0.326) 0.136 (0.30) 0.142 (0.313) 0.131 (0.289) 0.144 (0.317) 0.133 (0.293) 0.107 (0.236) 0.102 (0.225) 0.142 (0.313) 0.131 (0.289) 0.145 (0.32) 0.133 (0.293) 0.14 (0.309) 0.129 (0.284) 0.123 (0.271) 0.115 (0.254) 40 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Ordering details - singlefunctional devices CT-ERS.21P CT-AHS.22P CT-SDS.23P M Control input with voltage-related triggering m Control input with volt-free triggering m / m Two control inputs with volt-free triggering - No triggering 2CDC 251 040 V0011 2CDC 251 033 V0011 2CDC 251 030 V0011 -- Ordering details Timing function Rated control Time supply ranges voltage Control Output Type input Order code ON-delay 24-240 V AC/ 10 (0.05 s - DC - 300 h) 2 c/o CT-ERS.21S1) 1SVR730100R0300 CT-ERS.21P1) 1SVR740100R0300 24-48 V DC, 24-240 V AC CT-ERS.22S 1SVR730100R3300 CT-ERS.22P 1SVR740100R3300 24-48 V DC, 24-240 V AC - 1 c/o CT-ERS.12S 1SVR730100R3100 CT-ERS.12P 1SVR740100R3100 OFFdelay 24-240 V AC/ 10 (0.05 s M DC - 300 h) 2 c/o CT-APS.21S1) 1SVR730180R0300 CT-APS.21P1) 1SVR740180R0300 24-48 V DC, 24-240 V AC CT-APS.22S 1SVR730180R3300 CT-APS.22P 1SVR740180R3300 M 1 c/o CT-APS.12S 1SVR730180R3100 CT-APS.12P 1SVR740180R3100 24-48 V DC, 10 (0.05 s n 24-240 V AC - 300 h) 2 c/o CT-AHS.22S 1SVR730110R3300 CT-AHS.22P 1SVR740110R3300 OFFdelay2) 24-240 V AC/DC 7 (0.05 s - 10 min) 1 c/o CT-ARS.11S 1SVR730120R3100 CT-ARS.11P 1SVR740120R3100 - 2 c/o CT-ARS.21S 1SVR730120R3300 CT-ARS.21P 1SVR740120R3300 Stardelta changeover3) 24-48 V DC, 24-240 V AC 7 (0.05 s - 10 min) 380-440 V AC 2 n/o CT-SDS.22S 1SVR730210R3300 CT-SDS.22P 1SVR740210R3300 CT-SDS.23S 1SVR730211R2300 CT-SDS.23P 1SVR740211R2300 1) Extended temperature range -40 °C 2) Without auxiliary voltage 3) 50 ms transition time S: Screw connection P: Push-in / easy connect Weight (1 pc) kg (lb) 0.13 (0.287) 0.121 (0.267) 0.121 (0.267) 0.113 (0.249) 0.106 (0.234) 0.101 (0.222) 0.146 (0.322) 0.125 (0.276) 0.138 (0.304) 0.127 (0.28) 0.109 (0.24) 0.103 (0.227) 0.136 (0.30) 0.125 (0.276) 0.106 (0.234) 0.10 (0.22) 0.124 (0.273) 0.115 (0.254) 0.114 (0.251) 0.108 (0.238) 0.118 (0.26) 0.112 (0.247) ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 41 -- CT-S range Ordering details - Accessories MT-x50B 30 mm adapters Marker label 29.6 x 44.5 mm Marker label with scale 0-10 48.5 x 44.5 mm Sealable transparent cover for CT-S in new housing 2CDC 252 044 F0209 2CDC 252 043 F0209 2CDC 255 006 S0011 1SFC 151 139 V0001 2CDC 252 042 F0009 The CT-S range offers the possibility of using accessories such as a remote potentiometer to adjust the time delay or a sealable, transparent cover to protect against unauthorized changes of time and threshold values. -- Remote potentiometer 50 kq ±20 % - 0.2 q, degree of protection IP66 Material Plastic, black Plastic, chrome Metal, chrome Diameter in mm 22.5 22.5 22.5 Type MT-150B MT-250B MT-350B Order code 1SFA611410R1506 1SFA611410R2506 1SFA611410R3506 Pack.unit pieces 1 1 1 Weight 1 piece g / oz 0.040 0.040 0.048 -- 30 mm adapter for attaching the potentiometer 22 mm in 30 mm mounting hole Material Plastic, black Metal, chrome Type K A1- 8029 K A1- 8030 Order code 1SFA616920R8029 1SFA616920R8030 Pack.unit pieces 1 1 Weight 1 piece g / oz -- Marker label Caption Symbol (see illustration) Scale 0 - 10 Scale 0 - 30 Type Order code SK 615 562-87 SK 615 562-88 MA16-1060 GJD6155620R0087 GJD6155620R0088 1SFA611940R1060 Pack.unit pieces 1 1 1 Weight 1 piece g / oz 0.002 0.002 0.002 -- Accessories for CT-S Description Type Adapter for screw mounting Sealable transparent cover Marker label for devices w/o DIP switches Marker label for devices with DIP switches ADP.01 COV.11 MAR.01 MAR.12 Order code 1SVR430029R0100 1SVR730005R0100 1SVR366017R0100 1SVR730006R0000 Pack.unit pieces 1 1 10 10 Weight 1 piece g / oz 0.018 (0.040) 0.004 (0.009) 0.001 (0.002) 0.001 (0.002) 42 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated CT-S Input circuit - Supply circuit Rated control supply voltage Us CT-xxx.x1 24-240 V AC/DC CT-xxx.x2 24-48 V DC, 24-240 V AC CT-xxx.x3 380-440 V AC Rated control supply voltage US tolerance Rated frequency -15...+10 % DC or 50/60 Hz Frequency range AC 47-63 Hz Typical power consumption max. 16 VA Power failure buffering time 24 V DC min. 15 ms 230/400 V AC min. 20 ms Release voltage Minimum energizing time > 10 % of the minimum rated control supply voltage Us 100 ms (CT-ARS) Formatting time 1) 5 min (CT-ARS) Input circuit - Control circuit Kind of triggering CT-MVS, CT-MXS, CT-APS voltage-related triggering Control input, Control function A1-Y1/B1 start timing external Parallel load / polarized yes / no Maximum cable length to the control input 50 m - 100 pF/m Minimum control pulse length 20 ms Control voltage potential see rated control supply voltage Current consumption of the control input 24 V DC 1.2 mA 230 V AC 8 mA 400 V AC 6 mA Kind of triggering CT-MFS, CT-MBS, CT-AHS volt-free triggering Control input, Control function Y1-Z2 start timing external X1-Z2 pause timing / accumulative functions (CT-MFS) Maximum switching current in the control circuit 1 mA Maximum cable length to the control input 50 m - 100 pF/m Minimum control pulse length 20 ms No-load voltage at the control inputs 10-40 V DC Remote potentiometer Remote potentiometer connections, resistance value Z1-Z2 50 k (CT-MFS, CT-MBS, CT-MVS.21, CT-MXS) Z3-Z2 50 k (CT-MXS) Maximum cable length to remote potentiometer 2 x 25 m, shielded with 100 pF/m Shield connection Z2 Timing circuit Time ranges 10 time ranges 0.05 s - 300 h 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s 4.) 1.5-30 s 5.) 5-100 s 6.) 15-300 s 7.) 1.5-30 min 8.) 15-300 min 9.) 1.5-30 h 10.) 15-300 h 7 time ranges 0.05 s - 10 min (CT-SDS, CT- 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s ARS) 4.) 1.5-30 s 5.) 5-100 s 6.) 15-300 s 7.) 0.5-10 min Recovery time 24-240 V AC/DC < 50 ms 24-48 V DC, 24-240 V AC < 80 ms 380-440 V AC < 60 ms Accuracy within the rated control supply voltage tolerance it < 0.004 % / V Accuracy within the temperature range Repeat accuracy (constant parameters) Setting accuracy of time delay it < 0.03 % / °C < ±0.2 % ±6 % of full-scale value Star-delta transition time Star-delta transition time tolerance fixed 50 ms (CT-SDS, CT-MBS, CT-MFS, CT-MVS.2x) ±2 ms 1) Prior to first commisioning and after a six-month stop in operation ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 43 -- CT-S range Technical data Indication of operational states Control supply voltage / timing U/T: green LED V: control supply voltage applied / W: timing Control supply voltage U: green LED V: control supply voltage applied Relay state R, R1, R2: yellow LED V: output relay energized Output circuit Kind of output 15-16/18 relay, 1 c/o contact 15-16/18; 25-26/28 relay, 2 c/o contacts 15-16/18; 25(21)-26(22)/28(24) relay, 2 c/o contacts, 2nd c/o contact selectable as inst. contact 17-18; 17-28 relay, 2 n/o contacts (CT-SDS) Contact material Cd-free, on request Rated operational voltage Ue IEC/EN 60947-1 250 V Minimum switching voltage / minimum switching current 12 V / 100 mA Maximum switching voltage / maximum switching current see load limit curves Rated operational current Ie AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A (CT-ARS; 1.5 A) AC rating (UL 508) utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC maximum continuous thermal current at B300 5 A max. making/breaking apparent power at B300 3600 VA / 360 VA Mechanical lifetime 30 x 106 switching cycles Electrical lifetime at AC-12, 230 V, 4 A 0.1 x 106 switching cycles Frequency of operation with/without load 360/72000 h-1 CT-ARS: 1200/18000 h-1 Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting General data MTBF on request Duty cycle 100% Dimensions see `Dimensional drawings' Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical / horizontal not necessary / not necessary Material of housing UL 94 V-0 Degree of protection housing / terminals IP50 / IP20 Electrical connection Screw connection technology Easy Connect Technology (Push-in) Connecting capacity fine-strand with(out) wire end 1 x 0.5-2.5 mm2 (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm2 (2 x 18-16 AWG) 2 x 0.5-1.5 mm2 (2 x 18-16 AWG) rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm2 (2 x 20-14 AWG) 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) Stripping length Tightening torque 8 mm (0.32 in) 0.6-0.8 Nm (7.08 lb.in) - 44 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Technical data Environmental data Ambient temperature ranges operation / storage -25...+60 °C / -40...+85 °C, -40...+60 °C / -40...+85 °C for CT-MVS.21, CT-MFS.21, CT-ERS.21, CT-APS.21 Relative humidity range 25 % to 85 % Vibration, sinusoidal (IEC/EN 60068-2-6) functioning 40 m/s2, 10-58/60-150 Hz resistance 60 m/s2, 10-58/60-150 Hz, 20 cycles Vibration, seismic (IEC/EN 60068-3-3) functioning 20 m/s2 Shock, half-sine (IEC/EN 60068-2-27) functioning 150 m/s2, 11 ms, 3 shocks/direction resistance 300 m/s2 , 11 ms, 3 shocks/direction Isolation data CT-S with 1 c/o CT-S with 2 c/o Rated insulation voltage Ui input circuit / output circuit 500 V output circuit 1 / output circuit 2 not available 300 V Rated impulse withstand voltage Uimp between all isolated circuits 4 kV; 1.2/50 µs except devices CT-xxx.23: input / output: 6 kV; 1.2/50 µs output 1 / output 2: 4 kV; 1.2/50 µs Power-frequency withstand voltage (test voltage) between all isolated circuits 2.0 kV; 50 Hz; 60 s Basic insulation (IEC/EN 61140) Protective separation (IEC/EN 61140; EN 50178) Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency electromagnetic field input circuit / output circuit 500 V input circuit / output circuit 250 V 3 III IEC/EN 61812-1 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) 3 V/m (2 GHz) 1 V/m (2.7 GHz) electrical fast transient / burst surge conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 Level 4, 2 kV A1-A2 IEC/EN 61000-4-6 Level 3, 10 V harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted IEC/EN 61000-4-13 Class 3 IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 45 -- CT-S range Technical diagrams -- DIP switch configuration CT-MXS.22x 4 3 21 ON OFF Pulse generator, starting with ON or OFF ON OFF Single pulse generator, starting with OFF ON OFF Asymmetrical ON- and OFF-delay ON OFF Impulse-ON and Impulse-OFF ON OFF No function ON OFF ON/OFF function Default setting: all DIP switches in position OFF -- Example of application - Star-delta changeover L1 F3 95 F2 96 S1 21 0 22 S2 13 53 I K2 14 54 17 K1T 18 17 13 13 K2 K1 28 14 14 22 K3 21 22 K1 21 K1T N A1 A1 A1 A1 K1 K3 K2 A2 A2 A2 A2 Y i N Control circuit diagram L1 L2 L3 135 -F1 246 135 -K2 2 4 6 135 135 -K3 2 4 6 -K1 2 4 6 154 -F2 326 97 95 98 96 -M1 W1 W2 V1 M V2 U1 3 ~ U2 Power circuit diagram 2CDC252128F0006 2CDC 252 128 F0b06 2CDC253009F0012 2CDC 253 009 F0012 46 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Technical diagrams 2CDC252002F0b06 2CDC 252 002 F0b06 2CDC252003F0b06 2CDC 252 003 F0b06 2CDC252003F0b06 2CDC 252 003 F0b06 2CDC252004F0b06 2CDC 252 004 F0b06 -- Connection diagrams CT-MVS.21 A1 15 Y1/B1 Z2 Y1/ B1 A1 15 25 21 Z1 25 21 CT-MVS.22 A1 15 25 Y1/B1 Y1/ B1 A1 15 25 A2 16 18 26 28 22 24 28 24 26 22 18 16 A2 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 24-240 V AC/DC A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact 21-22/24 2nd c/o contact as instantaneous contact Z1-Z2 Remote potentiometer connection A1-A2 Supply: 224-48 V DC or 24-240 V AC A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact CT-MVS.23 A1 15 25 Y1/B1 Y1/ B1 A1 15 25 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 380-440V AC A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact CT-MVS.12 A1 15 Y1/B1 Y1/ B1 A1 15 A2 16 18 18 16 A2 A1-A2 Supply: 24-48 V DC or 24-240 V AC A1-Y1/B1 Control input 15-16/18 1st c/o contact 2CDC252005F0b06 2CDC 252 005 F0b06 2CDC252006F0b06 2CDC 252 006 F0b06 2CDC252007F0b06 2CDC 252 007 F0b06 2CDC252008F0b06 2CDC 252 008 F0b06 CT-MXS.22 A1 15 25 Z3 Z2 Z1 Y1/ B1 A1 15 25 CT-MFS.21 A1 15 X1 Z2 A1 15 25 21 Z1 25 21 CT-MBS.22 A1 15 Z2 A1 15 25 21 Z1 25 21 CT-WBS.22 A1 15 25 A1 15 25 A2 16 18 26 28 28 26 Y1/B1 18 16 A2 A2 16 18 28 24 26 22 18 16 26 28 22 24 Y1 A2 A2 16 18 28 24 26 22 18 16 26 28 22 24 Y1 A2 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 24-48 V DC or 24-240 V AC A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact Z1-Z2 Remote potentiometer connection Z3-Z2 Remote potentiometer connection A1-A2 Supply: 24-240 V AC/DC 15-16/18 1st c/o contact 25-26/28 2nd c/o contact 21-22/24 2nd c/o contact as instantaneous contact Y1-Z2 X1-Z2 Z1-Z2 Control input Control input Remote potentiometer connection A1-A2 Supply: 24-48 V DC or 24-240 V AC 15-16/18 1st c/o contact 25-26/28 2nd c/o contact 21-22/24 2nd c/o contact as instantaneous contact Y1-Z2 Control input Z1-Z2 Remote potentiometer connection A1-A2 Supply: 24-48 V DC or 24-240 V AC 15-16/18 1st c/o contact 25-26/28 2nd c/o contact ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 47 -- CT-S range Technical diagrams -- Connection diagrams A CT-ERS.21 A1 15 25 A1 15 25 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 24-240 V AC/DC 15-16/18 1st c/o contact 25-26/28 2nd c/o contact B CT-APS.21 A1 15 25 Y1/B1 Y1/ B1 A1 15 25 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 24-240 V AC/DC A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact B CT-ARS.11 A1 15 A1 15 A2 16 18 18 16 A2 A1-A2 Supply: 24-240 V AC/DC 15-16/18 1st c/o contact 2CDC252014F0b06 2CDC 252 014 F0b06 2CDC252015F0b06 2CDC 252 015 F0b06 2CDC252011F0b06 2CDC 252 011 F0b06 2CDC252002F0b06 2CDC 252 009 F0b06 2CDC252010F0b06 2CDC 252 010 F0b06 2CDC252009F0b06 2CDC 252 009 F0b06 A CT-ERS.22 A1 15 25 A1 15 25 A CT-ERS.12 A1 15 A1 15 A2 16 18 26 28 28 26 18 16 A2 A2 16 18 18 16 A2 A1-A2 Supply: 24-48 V DC or 24-240 V AC 15-16/18 1st c/o contact 25-26/28 2nd c/o contact A1-A2 Supply: 24-48 V DC or 24-240 V AC 15-16/18 1st c/o contact 2CDC252013F0b06 2CDC 252 013 F0b06 2CDC252012F0b06 2CDC 252 012 F0b06 2CDC252011F0b06 2CDC 252 011 F0b06 B CT-APS.22 A1 15 25 Y1/B1 Y1/ B1 A1 15 25 B CT-APS.12 A1 15 Y1/B1 Y1/ B1 A1 15 B CT-AHS.22 A1 15 25 Z2 A1 15 25 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 24-48 V DC or 24-240 V AC A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact A2 16 18 18 16 A2 A1-A2 Supply: 24-48 V DC or 24-240 V AC A1-Y1/B1 Control input 15-16/18 1st c/o contact A2 16 18 26 28 28 26 Y1 18 16 A2 A1-A2 Supply: 24-48 V DC or 24-240 V AC Y1-Z2 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact B CT-ARS.21 A1 15 25 A1 15 25 A2 16 18 26 28 28 26 18 16 A2 A1-A2 Supply: 24-240 V AC/DC 15-16/18 1st c/o contact 25-26/28 2nd c/o contact 2CDC252016F0b06 2CDC 252 016 F0b06 2CDC252016F0b06 2CDC 252 016 F0b06 F CT-SDS.22 A1 17 A1 17 F CT-SDS.23 A1 17 A1 17 A2 18 28 18 28 A2 A1-A2 17-18 17-28 Supply: 24-48 V DC or 24-240 V AC 1st n/o contact 2nd n/o contact A2 18 28 18 28 A2 A1-A2 17-18 17-28 Supply: 380-440 V AC 1st n/o contact 2nd n/o contact 2CDC252193F0205 2CDC 252 193 F0205 48 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-S range Technical diagrams -- Load limit curves AC load (resistive) V 300 V 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F -- Derating factor F for inductive AC load 1.0 0.9 0.8 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 2CDC252124F0206 2CDC 252 124 F0206 2CDC252194F0205 2CDC 252 194 F0205 DC load (resistive) V 300 U 200 100 80 60 50 40 30 20 10 0,1 0,2 0,5 1 2 4 6 10 I A -- Contact lifetime Switching cycles 250 V resistive load Switching current [A] 2CDC 252 148 F0206 2CDC252148F0206 -- Wiring notes Control inputs (volt-free triggering) L(+) A1 X1 Y1 A2 Z2 N(-) 2CDC 252 101 F0b06 Triggering of the control inputs (volt-free) with a proximity switch (3 wire) L(+) +V A1 Y1 2CDC 252 105 F0b06 A2 Z2 N(-) 0 V 2CDC252105F0b06 2CDC252101F0b06 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 49 -- CT-S range Technical diagrams 2CDC 252 104 F0b06 2CDC252104F0b06 -- Wiring notes Control inputs (voltage-related triggering) L(+) A1 Y1/B1 L(+) L(+) A1 Y1/B1 Remote potentiometer L(+) A1 Z3 Z1 2CDC 252 103 F0b06 2CDC 252 102 F0b06 2CDC252103F0b06 2CDC252102F0b06 A2 A2 A2 Z2 N(-) N(-) L(-) N(-) The control input Y1/B1 is triggered with electric potential against A2. It is possible to use the control supply voltage from terminal A1 or any other voltage within the rated control supply voltage range. -- Dimensional drawings in mm and inches 113.4 4.47" 105.9 4.17" 22.5 0.89" 85.6 3.37" 2CDC25008F0010 2CDC252009F0011 68 2.68" 2CDC252010F0011 8 0.315" 2CDC252186F0005 Main device 103.7 4.08" 22.5 0.89" 8 0.32" 4.8 0.19" front to back 110.5 4.31" COV.11 sealable transparent cover ADP.01 adapter for screw mounting 3A11 20 0.787" MAR.01 marker label 50 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 51 -- Time relays for building applications Table of contents 53 Applications 54 CT-D range 54 Benefits and advantages 56 Selection table 57 Ordering details 58 Technical data 62 Technical diagrams 52 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 53 -- Time relays for building applications Applications The CT-D range is designed in a modular housing, making it well suited for building and residential applications. In just 12 order codes the CT-D range covers all the main timing functions needed for building automation, safely and reliably. A typical application for timers is delayed switching. Switching several rows of lamps on and off in corridors, stairwells, staircases, etc, is a widespread application in which the excellent functionality of the CT-D timers is undisputed. Air conditioning systems, heaters and fans can be found everywhere in buildings - just like the CT-D timers long used to switch them. On-delay, off-delay and a range of other functions cover all requirements. Elevators, escalators, gates, compressors and doors - here too ABB timers ensure optimum and time-delayed opening as required. ABB s CT-D timers cover most functions with just 12 order codes. 54 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-D range Benefits and advantages The CT-D range is ideal for building applications and installation panels, due to its compact modular housing. For maximum flexibility in operation, nine single-function as well as two multifunction devices with seven timing functions are available. The devices offer four or seven time ranges from 0.05 seconds up to 100 hours. Their wide supply voltage range allows their use in applications worldwide. Space savings The CT-D range is ideal for installation panels thanks to its compact modular housing. The housing's design helps make the status and configuration more clearly visible. The CT-D range also offers a higher output current than standard industrial types. As well as the 1 c/o contacts, ABB offers devices with 2 c/o contacts for maximum flexibility. Easy to install Direct reading scales help make time setting quick and easy. A pre-selection for the time range together with an additional scale for fine adjustments help improve installation efficiency. For more flexibility, the delay time can even be changed when processes are running, making optimization to fit the application even simpler. All devices can be mounted and demounted tool-free. Global availabilty The CT-D range fulfills various global standards and approvals, supporting business worldwide. Additionally, all devices from the CT-D range have a wide supply voltage from 24-48 V DC and 24-240 V AC, making it ideal for the use in installation panels around the world. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 55 -- CT-D range Operating controls Connection terminals Wide terminal spacing makes connection of wires simpler: 2 x 1.5 mm² (2 x 16 AWG) with wire end ferrules or 2 x 2.5 mm² (2 x 14 AWG) without ferrules. Width 17.5 mm With a width of just 17.5 mm, the CT-D range timers are ideally suited for installation in distribution panels. Preselection of the time range Direct reading scales Direct setting of the time delay without any additional calculation provides accurate time delay adjustment. Selection of the timing function A ON-delay B OFF-delay with aux. voltage CA Impulse-ON CB Impulse-OFF with aux. voltage DA Flasher starting with ON DB Flasher starting with OFF H Pulse former Fine adjustment of the time delay LEDs for status indication All actual operational states are displayed by front-facing LEDs, thus simplifying commissioning and troubleshooting. · U - green LED: V control supply voltage applied / W timing · R, R1, R2 - yellow LED: V output relay energized 56 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-D range Selection table Order number 1SVR500020R0000 1SVR500020R1100 1SVR500100R0000 1SVR500100R0100 1SVR500110R0000 1SVR500110R0100 1SVR500130R0000 1SVR500150R0000 1SVR500160R0000 1SVR500160R0100 1SVR500210R0100 1SVR500211R0100 Type CT-MFD.12 CT-MFD.21 CT-ERD.12 CT-ERD.22 CT-AHD.12 CT-AHD.22 CT-VWD.12 CT-EBD.12 CT-TGD.12 CT-TGD.22 CT-SAD.22 CT-SDD.22 Timing function ON-delay AJJJJ OFF-delay with aux. voltage BJJ JJ Impulse-ON CA J J J Impulse-OFF with aux. voltage CB J J Flasher starting with ON DA J J J Flasher starting with OFF DB J J Pulse generator starting with ON or OFF ED JJ Pulse former HJJ Star-delta change-over F JJ Features Control input, voltage-related triggering JJ JJ JJ Time range 0.05 s - 100 h 0.05 s - 10 min JJJJJJJJ2 2 JJ Supply voltage 12-240 V AC/DC 24-48 V DC 24-240 V AC J J JJJJJJJJJJ J JJJJJJJJJJ Output c/o contact 1212121112 n/o contact 22 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 57 -- CT-D range Ordering details Description The CT-D range with its modular design is a perfect solution for installation panels. For maximum flexibility in operation, 10 single-function as well as two multifunction devices with seven timing functions are available. The devices offer four or seven time ranges from 0.05 seconds up to 100 hours. Their wide input range allows their use in applications worldwide. 2CDC251002V0018 CT-MFD.12 CT-ERD.22 M Control input with voltage-related triggering - No triggering 2CDC251002V0018 -- Ordering details Timing function Rated control Time supply ranges voltage Control Output Type input Order code Multi1) 24-240 V AC 7 (0.05 s - M 24-48 V DC 100 h) Multi1) 12-240 V AC/DC 7 (0.05 s - M 100 h) ON-delay 24-240 V AC 7 (0.05 s - 24-48 V DC 100 h) - 1 c/o CT-MFD.12 1SVR500020R0000 2 c/o CT-MFD.21 1SVR500020R1100 1 c/o CT-ERD.12 1SVR500100R0000 2 c/o CT-ERD.22 1SVR500100R0100 OFF-delay M 1 c/o CT-AHD.12 1SVR500110R0000 M 2 c/o CT-AHD.22 1SVR500110R0100 ImpulseON Flasher starting with ON Pulse generator - 2×7 (0.05 s - M 100 h) M 1 c/o CT-VWD.12 1SVR500130R0000 CT-EBD.12 1SVR500150R0000 CT-TGD.122) 1SVR500160R0000 2 c/o CT-TGD.222) 1SVR500160R0100 Star-delta changeover 4 (0.05 s - 10 min) - 2 n/o CT-SDD.223) 1SVR500211R0100 CT-SAD.224) 1SVR500210R0100 1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former 2) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h 3) Transition time 50 ms fixed 4) Transition time adjustable Weight (1 pc) kg (lb) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.060 (0.132) 0.065 (0.143) 0.065 (0.143) 58 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-D range Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated CT-D with 1 c/o contact CT-D with 2 c/o contacts CT-MFD.21 Input circuit - Supply circuit Rated control supply voltage Us 24-240 V AC / 24-48 V DC 12-240 V AC/DC Rated control supply voltage US tolerance -15...+10 % Rated frequency DC or 50/60 Hz Frequency range AC 47-63 Hz Typical power consumption max. 3.5 VA Power failure buffering time min. 20 ms Release voltage > 10 % of the minimum rated control supply voltage Us Input circuit - Control circuit Control input, control function A1-Y1/B1 start timing external Kind of triggering voltage-related triggering Resistance to reverse polarity yes Parallel load / polarized yes / yes Maximum cable length to the control inputs 50 m 100 pF/m Minimum control pulse length 20 ms Control voltage potential see rated control supply voltage Current consumption of the control input see data sheet Timing circuit Time ranges 7 time ranges 0.05 s - 100 h 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min 5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h 4 time ranges 0.05 s - 10 min (CT-SDD, CT-SAD) 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min Recovery time < 50 ms Accuracy within the rated control supply voltage tolerance it < 0.005 % / V Accuracy within the temperature range Repeat accuracy (constant parameters) Setting accuracy of time delay Star-delta transition time it < 0.06 % / °C it < ± 0.5 % ± 10% of full-scale value CT-SDD/ CT-SAD fixed 50 ms / adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms Star-delta transition time tolerance Indication of operational states Control supply voltage / timing CT-SDD / CT-SAD ±3 ms U: green LED V: control supply voltage applied W: timing Relay energized R, R1, R2: yellow LED V: output relay energized Operating elements and controls Adjustment of the time range Fine adjustment of the time value Preselection of the timing function at multifunction devices Adjustment of the transition time front-face rotary switch, direct reading scales front-face potentiometer front-face rotary switch, direct reading scales CT-SAC front-face potentiometer ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 59 -- CT-D range Technical data CT-D with 1 c/o contact CT-D with 2 c/o contacts CT-MFD.21 Output circuit Kind of output 15-16/18 Relay, 1 c/o contact - 15-16/18; 25-26/28 - Relay, 2 c/o contacts 17-18; 17-28 Relay, 2 n/o contacts (CT-SDC, CT-SAC) Contact material AgNi alloy, Cd free Rated operational voltage Ue 250 V Minimum switching voltage / minimum switching current 12 V / 100 mA Maximum switching voltage / maximum switching current 250 V AC / 6 A 250 V AC / 5 A Rated operational current Ie AC-12 (resistive) at 230 V 6 A 5 A AC-15 (inductive) at 230 V 3 A 3 A n/o: 3 A n/c: 0.75 A DC-12 (resistive) at 24 V 6 A 5 A DC-13 (inductive) at 24 V 2 A 2 A 1 A AC rating (UL 508) utilization category (Control Circuit Rating Code) B 300 n/o: B 300 n/c: C 300 max. rated operational voltage 300 V AC maximum continuous thermal current at B300 5 A n/o: 5 A maximum continuous thermal current at C300 - n/c: 2.5 A max. making/breaking apparent power at B300 3600 VA / 360 VA n/o: 3600/360 VA max. making/breaking apparent power at C300 - n/c: 1800/180 VA Mechanical lifetime 30 x 106 switching cycles Electrical lifetime 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting 6 A fast-acting General data Mean time between failures (MTBF) on request Duty cycle 100% Dimensions see `Dimensional drawings' Mounting DIN rail (IEC/EN 60715), snap-mounting without any tool Mounting position any Minimum distance to other units horizontal / vertical no / no Degree of protection housing / terminals IP50 / IP20 Electrical connection Connecting capacity fine-stranded with(out) 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) wire and ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG) rigid 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) 1 x 0.5-4 mm2 (1 x 20-12 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.5-0.8 Nm (4.43-7.08 lb.in) Environmental data Ambient temperature range operation / storage -20 ... +60 °C / -40 ... +85 °C Climatic class EC/EN 60068-2-30 3K3 Relative humidity range 25-85% Vibration, sinusoidal IEC/EN 60068-2-6 20 m/s²; 10 cycles, 10...150...10 Hz Shock (half-sine) IEC/EN 60068-2-27 150 m/s2, 11 ms 60 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-D range Technical data CT-D with 1 c/o contact Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Power-frequency withstand voltage test(test voltage) input circuit / output circuit 300 V output circuit 1 / output circuit 2 not available between all isolated circuits 4 kV; 1.2/50 µs between all isolated circuits 2.5 kV; 50 Hz; 60 s Basic insulation (IEC/EN 61140) input circuit / output circuit 300 V Protective separation (IEC/EN 61140, EN 50178) input circuit / output circuit 250 V Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 61812-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V / m) electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz) surge IEC/EN 61000-4-5 Level 4 (2 kV L-L) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 (10 V) Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B CT-D with 2 c/o contacts 300 V CT-MFC.21 300 V ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 61 -- CT-D range Technical diagrams -- Example of application - Star-delta changeover L1 F3 95 F2 96 S1 21 0 22 S2 13 53 I K2 14 54 17 K1T 18 17 13 13 K2 K1 28 14 14 22 K3 21 22 K1 21 K1T N A1 A1 A1 A1 K1 K3 K2 A2 A2 A2 A2 Y i N Control circuit diagram L1 L2 L3 135 -F1 246 135 -K2 2 4 6 135 135 -K3 2 4 6 -K1 2 4 6 154 -F2 326 97 95 98 96 -M1 W1 W2 V1 M V2 U1 3 ~ U2 Power circuit diagram 2CDC252128F0006 2CDC 252 128 F0b06 2CDC253009F0012 2CDC 253 009 F0012 62 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- CT-D range Technical diagrams -- Connection diagrams CT-MFD.21 A1 15 25 Y1/ B1 A1 15 25 CT-MFD.12 A1 15 Y1/ B1 A1 Y1/B1 15 A CT-ERD.22 A1 15 25 A1 15 25 A CT-ERD.12 A1 15 A1 15 2CDC252113F0b06 2CDC 252 113 F0b06 2CDC252114F0b06 2CDC 252 114 F0b06 2CDC252115F0b06 2CDC 252 115 F0b06 2CDC252177F0b05 2CDC 252 177 F0b05 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 A1-A2 A1-Y1/B1 15-16/18 25-26/28 Supply: 12-240 V AC/DC Control input 1st c/o contact 2nd c/o contact A2 16 18 18 16 A2 A1-A2 A1-Y1/B1 15-16/18 Supply: 24-48 V DC or 24-240 V AC Control input 1st c/o contact A2 16 18 26 28 18 16 28 26 A2 A1-A2 15-16/18 25-26/28 Supply: 24-48 V DC or 24-240 V AC 1st c/o contact 2nd c/o contact A2 16 18 18 16 A2 A1-A2 15-16/18 Supply: 24-48 V DC or 24-240 V AC 1st c/o contact 2CDC252116F0b06 2CDC 252 116 F0b06 2CDC252117F0b06 2CDC 252 117 F0b06 2CDC252179F0b05 2CDC 252 179 F0b05 B CT-AHD.22 A1 15 25 Y1/ B1 A1 15 25 B CT-AHD.12 A1 15 Y1/ B1 A1 Y1/B1 15 CA CT-VWD.12 A1 15 A1 15 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 A2 16 18 18 16 A2 A2 16 18 18 16 A2 A1-A2 A1-Y1/B1 15-16/18 25-26/28 Supply: 24-48 V DC or 24240 V AC Control input 1st c/o contact 2nd c/o contact A1-A2 A1-Y1/B1 15-16/18 Supply: 24-48 V DC or 24240 V AC Control input 1st c/o contact A1-A2 15-16/18 Supply: 24-48 V DC or 24240 V AC 1st c/o contact 2CDC252118F0b06 2CDC 252 118 F0b06 2CDC252119F0b06 2CDC 252 119 F0b06 2CDC 252160F0b06 2CDC 252 160 F0b06 2CDC 252160F0b06 2CDC 252 160 F0b06 ED CT-TGD.22 A1 15 25 Y1/ B1 A1 15 25 ED CT-TGD.12 A1 15 Y1/ B1 A1 Y1/B1 15 F CT-SDD.22 A1 17 A1 17 F CT-SAD.22 A1 17 A1 17 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 A1-A2 A1-Y1/B1 15-16/18 25-26/28 Supply: 24-48 V DC or 24-240 V AC Control input 1st c/o contact 2nd c/o contact A2 16 18 18 16 A2 A2 18 28 28 18 A2 A2 18 28 28 18 A2 A1-A2 A1-Y1/B1 15-16/18 Supply: 24-48 V DC or 24240 V AC Control input 1st c/o contact A1-A2 17-18 17-28 Supply: 24-48 V DC or 24-240 V AC 1st n/o contact (star contactor) 2nd n/o contact (delta contactor) A1-A2 17-18 17-28 Supply: 24-48 V DC or 24-240 V AC 1st n/o contact (star contactor) 2nd n/o contact (delta contactor) ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 63 -- CT-D range Technical diagrams 2CDC252124F0206 2CDC 252 124 F0206 2CDC 252 123 F0206 -- Load limit curves AC load (resistive) CT-D.1x resistive load AC voltage [V] CT-D.2x AC current [A] 2CDC252044F0207 2CDC 252 044 F0207 DC voltage [V] DC load (resistive) CT-D.1x resistive load CT-D.2x DC current [A] 2CDC252045F0207 2CDC 252 045 F0207 Derating factor F -- Derating factor F for inductive AC load 1.0 0.9 0.8 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos -- Contact lifetime DC voltage [V] 2CDC 252 122 F0206 resistive load resistive load 250 V resistive load 2CDC2520121F0206 2CDC 252 121 F0206 Switching cycles AC voltage [V] 2CDC252122F0206 AC current [A] DC current [A] -- Wiring notes for devices with control input A parallel load to the control input is possible L(+) A1 Y1/B1 -- Dimensional drawings in mm and inches 0.69" 17,5 58 2.28" 0.2" 5 43,4 1.71" A2 N(-) CT-D devices with 1 c/o contact or 2 n/o contacts Switching current [A] 0.69" 17,5 58 2.28" 0.2" 5 43,4 1.71" CT-D devices with 2 c/o contacts 2CDC252123F0206 2CDC252102F0006 2CDC 252 102 F0b06 70 2.76" 45 1.77" 2 2CCDDCC2255212311F301b0F60b06 80 3.15" 45 1.77" 2CCDDCC2522512301F3000F006b06 64 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 65 -- Timing functions 66 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- Timing functions CT-C, CT-S, CT-D On delay functions (Delay on make) A On-delay Supply Output t This function requires a continuous control supply voltage for timing. Timing begins when a control supply voltage is applied. When the selected time delay is complete, the output relay energizes. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. ON-delay accumulative Supply Control input Output 2nd instanteous contact t t1 + t2 = t t1 t3 t2 t3 = pause OFF delay functions (Delay on break) B OFF-delay with auxiliary voltage Supply Control input Output t <t This function requires a continuous control supply voltage for timing. Timing begins when a control supply voltage is applied. When the selected time delay is complete, the output relay energizes. Timing can be paused by closing the control input. The elapsed time t1 is stored and continues from this time value when the control input is re-opened. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. If the control input is closed, the output relay energizes immediately. If the control input is opened, the time delay starts. When the selected time delay is complete, the output relay de-energizes. If control input re-closes before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when the control input re-opens. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. OFF-delay without auxiliary voltage Supply Output t The OFF-delay function without auxiliary voltage does not require a continuous control supply voltage for timing. Applying a control supply voltage energizes the output relay. If the control supply voltage is interrupted, the OFF-delay starts. When timing is complete, the output relay de-energizes. If a control supply voltage is re-applied before the time delay is complete, the time delay is reset and the output relay remains energized. A control supply voltage must be applied for the minimum energizing time (200 ms), for correct operation. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 67 -- Timing functions CT-C, CT-S, CT-D OFF-delay with auxiliary voltage, accumulative Supply Control input 1 Output 2nd instanteous contact Control input 2 t= delay t1 t3 t2 t=t1+t2 t3 = pause Impulse-ON functions CA Impulse-ON (interval) Supply Output t < t Impulse-ON, accumulative Supply Control input 1 Output 2nd instanteous contact Control input 2 t adjusted pulse time t1 t3 t2 t3 = pause This function requires a continuous control supply voltage for timing. If the control input is closed, the output relay energizes immediately. If the control input is opened, the time delay starts. When the selected time delay is complete, the output relay de-energizes. If the control input closes before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when the control input reopens. Pause timing / Accumulative OFF-delay: Timing can be paused by closing control 1. The elapsed time t1 is stored and continues from this time value when control input 1 is re-opened. This can be repeated as often as required. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. The output relay energizes immediately when the control supply voltage is applied and de-energizes after the set pulse time is complete. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. The output relay energizes immediately when the control supply voltage is applied and de-energizes after the set pulse time is complete. If control input 1 is open, timing begins when a control supply voltage is applied. Or, if control a supply voltage is already applied, opening control input 1 starts timing. When the selected pulse time is complete, the output relay de-energizes. Closing control input 1, before the pulse time is complete, de-energizes the output relay and resets the pulse time. Pause timing / Accumulative impulse-ON: Timing can be paused by closing control input 2. The elapsed time t1 is stored and continues from this time value when control input 2 is re-opened. This can be repeated as often as required. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. 68 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- Timing functions CT-C, CT-S, CT-D Impulse-OFF functions CB Impulse-OFF with auxiliary voltage Supply Control input Output t <t Impulse-OFF without auxiliary voltage Supply Output t Impulse-OFF with auxiliary voltage (Trailing edge interval) accumulative Supply Control input 1 Output t 2nd instanteous contact Control input 2 t1 t3 t2 t3 = pause t1 + t2 = t Impulse-ON and Impulse-OFF functions CE Impulse-ON and impulse-OFF Supply Control input Output t1 t2 <t1 This function requires a continuous control supply voltage for timing. The output relay energizes immediately when the control input is de-energized and the output de-energizes after the set pulse time is complete. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function does not require a continuous control supply voltage for timing. If the control supply voltage is interrupted, the output relay energizes and the OFF time starts. When timing is complete, the output relay de-energizes. If a control supply voltage is re-applied before the time delay is complete, the time delay is reset and the output relay de-energizes. A control supply voltage must be applied for the minimum energizing time (200 ms), for proper operation. This function requires a continuous control supply voltage for timing. If a control supply voltage is applied, opening control input 1 energizes the output relay immediately and starts timing. When the selected pulse time is complete, the output relay de-energizes. Closing control input 1, before the pulse time is complete, de-energizes the output relay and resets the pulse time. Pause timing / Accumulative impulse-OFF: Timing can be paused by closing control input 2. The elapsed time t1 is stored and continues from this time value when control input 2 is re-opened. This can be repeated as often as required. If the control supply voltage is interrupted, the output relay de- energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. If a control supply voltage is applied, closing the control input energizes the output relay immediately and starts the pulse time t1. When t1 is complete, the output relay de-energizes. Re-opening the control input energizes the output relay immediately and starts the pulse time t2. When t2 is complete, the output relay de-energizes. t1 and t2 are independently adjustable. If the control input changes state before the pulse time is complete, the output relay de-energizes and the pulse time is reset. If the control input changes state again, the interrupted pulse time restarts. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 69 -- Timing functions CT-C, CT-S, CT-D Flasher starting with ON functions DA Flasher starting with ON Supply Output t t Flasher with reset starting with ON Supply Control input Output t t 2nd contact instantaneous t t Flasher starting with OFF functions DB Flasher starting with OFF Supply Output t t Flasher with reset starting with OFF Supply Control input Output t t 2nd contact instantaneous t t Flasher starting with ON or OFF functions DE Flasher starting with ON or OFF Supply Control input Output t t 2nd contact instantaneous t t Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an ON time first. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an ON time first. The time delay can be reset by closing the control input. Opening the control input starts the timer pulsing again with symmetrical ON & OFF times. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an OFF time first. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an OFF time first. The time delay can be reset by closing the control input. Opening the control input starts the timer pulsing again with symmetrical ON & OFF times. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. Applying a control supply voltage starts timing with symmetrical ON / OFF times. If the control input is open while supply voltage is connected the cycle starts with an ON time first. If the control input is closed while supply voltage is connected the cycle starts with an OFF time first. 70 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS -- Timing functions CT-C, CT-S, CT-D Pulse former H Puls former (single shot) Supply Control input Output t t Single-pulse generator EC Single-pulse generator, starting with OFF Supply Control input Output t1 t2 t1 t2 Pulse generator ED Starting with the ON or OFF time (Recycling unequal times, ON or OFF first) Supply Control input Output t1 t2 t2 t1 Impulse with delay AC Fixed impulse with adjustable time delay Supply Output t1 t2 <t1 This function requires a continuous control supply voltage for timing. Closing the control input energizes the output relay immediately and starts timing. Operating the control input during the time delay has no effect. When the selected ON time is complete, the output relay de-energizes. After the ON time is complete, it can be restarted by closing the control input. If control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. Applying a control supply voltage while the control input is open energizes the output relay after the OFF time t1 is complete. When the following ON time t2 is complete, the output relay de-energizes. Alternatively, when a control supply voltage is already applied, the timing process can be started by opening control input. Closing the control input with a control supply voltage applied, de-energizes the output relay and re- sets the time delay. The ON & OFF times are independently adjustable. This function requires a continuous control supply voltage for timing. Applying a control supply voltage, with closed control input, starts timing with an OFF time first. Applying a control supply voltage, with open control input, starts timing with an ON time first. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. The time delay t1 starts when a control supply voltage is applied. When t1 is complete, the output relay energizes for the fixed impulse time t2 of 500 ms. If the control supply voltage is interrupted, the time delay is re- set. The output relay does not change state. Adjustable impulse with fixed time delay Supply Output t2 t1 t2 <t1 This function requires a continuous control supply voltage for timing. As soon as the control supply voltage is applied the output relay will close after 500 ms. When t2 is complete, the output relay energizes and the selected pulse time t1 starts. When t1 is complete, the output relay de-energizes. If the control supply voltage is interrupted, the pulse time is reset and the output relay de-energizes. ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 71 -- Timing functions CT-C, CT-S, CT-D ON- and OFF-delay AB Symmetrical ON- and OFF-delay 1) Supply Control input Output 2nd instanteous contact t1 t2 t1=t2 t1 <t2 Asymmetrical ON- and OFF-delay Supply Control input Output t1 t2 t1 <t2 Star-Delta changeover F FC Supply Output 1 Output 2 t1 t2 t1 = adjusted starting time t2 = transition time Further functions ON/OFF function G Supply Output Time sector 300 h Time sector = 300 h This function requires a continuous control supply voltage for timing. Closing the control input starts the ON-delay time t1. When timing is complete, the output relay energizes. Opening the control input starts the OFF-delay time t2. When the OFF-delay t2 is complete, the output relay de-energizes. If the control input opens before the ON-delay (<t1) is complete, the time delay is reset and the output relay remains de-energized. If control input closes before the OFF-delay time (<t2) is complete, the time delay is reset and the output relay remains energized. 1) Variant with 2nd control input for pause timing is available too. This function requires a continuous control supply voltage for timing. Closing the control input starts the ON-delay t1. When timing is complete, the output relay energizes. Opening the control input starts the OFF-delay t2. When the OFF-delay is complete, the output relay de-energizes. The ON-delay and OFF-delay are independently adjustable. If the control input opens before the ON-delay is complete (<t1), the time delay is reset and the output relay remains de-energized. If the control input closes before the OFF-delay is complete (<t2), the time delay is reset and the output relay remains energized. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset. This function requires a continuous control supply voltage for timing. Applying a control supply voltage, energizes the star contactor connected to output 1 and begins the set starting time t1. When the starting time is complete, the first output contact de-energizes the star contactor. When the transition time t2 is complete, the second output contact energizes the delta contactor. The delta contactor remains energized as long as the control supply voltage is applied. t2 is fixed to 50 ms or in some variants adjustable. This function is used for test purposes during commissioning and troubleshooting. If the selected maximum value of the time range is smaller than 300 hours (front-face potentiometer "Time sector" 300 h), applying a control supply voltage energizes the output relay immediately. Interrupting the control supply voltage, de-energizes the output relay. If the selected maximum value of the time range is 300 hours (front- face potentiometer "Time sector" = 300 h) and a control supply voltage is applied the output relay does not energize. 72 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 73 -- Measuring and monitoring relays Table of contents 74 Benefits and advantages 76 Offer overview 79 Applications 81 Single-phase monitoring relays 105 Three-phase monitoring relays 137 Grid feeding monitoring relays 151 Insulation monitoring relays 181 Thermistor motor protection relays 203 Temperature monitoring relays 219 Liquid level monitoring relays 241 Accessories 74 ERC CATALOG MEASURING AND MONITORING REL AYS -- Measuring and monitoring relays Benefits and advantages Higher utility class The plastic housing material used meets the requirements for the highest flammability class. (UL94 V-0 rated) Snap-on housing Tool-free DIN rail installation and deinstallation of the relay. Sealable transparent cover Protection against unauthorized changes of time and threshold values. ERC CATALOG MEASURING AND MONITORING REL AYS 75 -- Measuring and monitoring relays Benefits and advantages Easy Connect technology · Tool-free wiring and excellent vibration resistance. · Push-in terminals provide connection of wires up to 2 x 0.5 - 1.5 mm² (2 x 20 -16 AWG), rigid or fine-strand with or without wire end ferrules. · Excellent vibration resistance the right solution for harsh environments. Double-chamber cage connection terminals Double-chamber cage connection terminals provide connection of wires up to 2 x 0.5-2.5 mm² (2 x 20-14 AWG) rigid or fine-strand, with or without wire end ferrules. LEDs for status indication All actual operational states are displayed by front-face LEDs, simplifying commissioning and troubleshooting. Integrated marker label Integrated marker labels allow the product to be marked quickly and simply. No additional marker labels are required. 76 ERC CATALOG MEASURING AND MONITORING REL AYS -- Measuring and monitoring relays Offer overview Measuring and monitoring relays monitor and detect operating conditions with regard to phase, current, voltage, frequency, temperature, liquid level or insulation faults. The relays inform users about abnormal conditions and allow them to take necessary corrective actions before severe and costly failures can occur. Depending on the product model, measuring and monitoring relays are categorized into seven product families. Single-phase current monitoring relays · Monitoring of motor current consumption · Monitoring of lighting installations and heating circuits · Monitoring of transportation equipment overload · Monitoring of locking devices, electromechanical brake gear and locked rotors Single-phase voltage monitoring relays · Speed monitoring of DC motors · Monitoring of battery voltages and other supply networks Three-phase monitoring relays · Voltage monitoring of mobile three-phase equipment · Protection of personnel and installations against phase reversal · Monitoring of the supply voltage of machines and installations · Protection of equipment against damage caused by unstable supply voltage v · Switching to emergency or auxiliary supply · Protection of motors against damage caused by unbalanced phase voltages and phase loss · Suitable for HVAC applications L1 L2 L3 N V,f Grid feeding monitoring relays The CM-UFD.M* range monitors all voltage and frequency parameters in a grid and ensures the safe feeding of decentrally produced electrical energy into the grid. · Monitoring of the voltage with up to 2 thresholds for over- and undervoltage · Monitoring of the frequency with up to 2 thresholds for over- and under- frequency · ROCOF (rate of change of frequency) and vector shift detection · In compliance with several local standards ERC CATALOG MEASURING AND MONITORING REL AYS 77 -- Measuring and monitoring relays Offer overview Insulation monitoring relays · Monitoring of electrically isolated supply mains for insulation resistance failure · Detection of initial faults · Protection against earth faults Temperature monitoring relays Acquisition, messaging and regulation of temperatures of solid, liquid and gaseous media in processes and machines · Motor and system protection · Control panel temperature monitoring · Frost monitoring · Temperature limits for process variables, e.g. in the packing or electroplating industry · Control of systems and machines like heating, air-conditioning and ventilation systems, solar collectors, heat pumps or hot water supply systems · Bearing, gear oil and coolant monitoring Thermistor motor protection CM-MSE and CM-MSS provide full protection of motors with integrated PTC resistor sensors. Protection of motors against thermal overload, e. g. caused by insufficient cooling, heavy load starting conditions, undersized motors, etc. Liquid level monitoring relays · Protection of pumps against dry running · Protection against container overflow · Control of liquid levels · Detection of leaks · Control of mixing ratios 78 ERC CATALOG MEASURING AND MONITORING REL AYS -- Measuring and monitoring relays Offer overview CM-N range: Multifunctional range · 45 mm wide housing · Output contacts: 2 c/o (SPDT) contacts · Continuous voltage range (24-240 V AC/DC) or single-supply · Setting and operation via front-face operating controls · Adjustment of threshold values and switching hysteresis via direct reading scale · Adjustable time delays · Integrated and snap-fitted front-face marker label · Sealable transparent cover (accessory) CM-S range: Universal and multifunctional range · Only 22.5 mm wide housing · Output contacts: 1 or 2 c/o (SPDT) contacts · One supply voltage range or supplied by measuring circuit · Setting and operation via front-face operating controls · Adjustment of threshold values and switching hysteresis via direct reading scale · Integrated and snap-fitted front-face marker · Snap-on housing: The relays can be placed on a DIN rail tool-free - just snap it on or remove it tool-free · Sealable transparent cover (accessory) CM-E range: Economy range · Only 22.5 mm wide housing · Output contacts: 1 c/o contact or 1 n/o contact · One supply voltage range · One monitoring function · Cost-efficient solution for OEM applications · Preset monitoring ranges ERC CATALOG MEASURING AND MONITORING REL AYS 79 -- Measuring and monitoring relays Applications ABB offers a wide selection of measuring and monitoring relays to suit a wide range of applications for businesses worldwide. Excellent vibration resistance with the Easy Connect terminal technology and railway certifications for selected products ensure the operability, even in harsh environments. Automation panels · Textile industry - measuring and monitoring of motor voltage and current overload of, for example, looms. · Packaging industry - measuring and monitoring of motor voltage and current overload of, for example, conveyor belts. Infrastructure · Water and wastewater applications - monitoring the liquid level of water tanks and wastewater recycling plants. · Lifts - status monitoring of the three phase mains of, for example, construction lifts, passenger lifts and escalators. · Hoisting applications - construction cranes, harbor cranes. · Railway. Renewable energy · Solar - monitoring of the insulation resistance and the frequency and voltage of the public grid to keep electrical grids stable and meet local requirements. · Wind - temperature, current and voltage supervision of automation panels and electrical motors. Buildings · Lifts - status monitoring of the three phase mains of, for example, construction lifts, passenger lifts and escalators. · HVAC - monitoring of grid parameters, control and protection of loads. 80 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 81 -- Single-phase monitoring relays Table of contents 82 Benefits and advantages 84 Operating controls 86 Single-phase current monitoring relays 86 Selection table 87 Ordering details 88 Single-phase voltage monitoring relays 88 Selection table 89 Ordering details 90 Technical data 96 Technical diagrams 98 Function diagrams 82 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase monitoring relays Benefits and advantages For the monitoring of currents and voltages in single-phase AC/DC systems, ABB's CM-range contains a wide selection of powerful and compact devices, all in an only 22.5 mm wide housing. This product range includes current and voltage monitoring relays for over- and undercurrent and voltage protection from 3 mA to 15 A, and from 3 V to 600 V. Continuous operation Read the status of the relay at a glance: clear visualization of the device status via LEDs. Easy to adjust with rotary wheels and variants with push-in terminals make a quick and easy installation and setting possible. Reliable in harsh conditions All relays work reliably in environments with low temperatures down to -25 °C. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable, no matter the environment temperature, but is also durable to shock and vibration. Save time as retightening is no longer needed, and enhance the reliability and safety of the equipment. Easy installation Like all devices from the measuring and monitoring portfolio, the single-phase monitoring relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. For further configuration options, additional settings can be made via dip-switches, offering the flexibility to configure, for example, the working principle of the relays and the output configuration. The device can be set up before installation in the application and easy adjustments during the process are possible. ERC CATALOG MEASURING AND MONITORING REL AYS 83 -- Single-phase monitoring relays Benefits and advantages Characteristics current and voltage monitoring relays1) · Monitoring of DC and AC currents: 3 mA to 15 A · Monitoring of DC and AC voltages from 3-600 V · TRMS measuring principle · One device includes 3 current measuring ranges · One device includes 4 voltage measuring ranges: 3-30 V; 6-60 V; 30-300 V; 60-600 V · Over- and undercurrent monitoring · Over- and undervoltage monitoring · ON or OFF-delay configurable · Open- or closed-circuit principle configurable · Threshold values for >U and/or <U adjustable · Latching function configurable · Thresholds for >I and/or <I adjustable · Fixed hysteresis of 5 % · Start-up delay Tv adjustable 0; 0.1-30 s · Tripping delay Tv adjustable 0; 0.1-30 s · 1 x 2 c/o contacts (common signal) or 2 x 1 c/o contact (separate signals for >I and <I) configurable · 1 x 2 c/o contacts (common signal) or 2 x 1 c/o contact (separate signals for >U and <U) configurable · 22.5 mm width · 3 LEDs for the indication of operational states · Various approvals and marks 1) depending on device Applications · Protection of electronic or electromechanical devices against over- and under voltage or over- and under current · DC motor speed control · Battery monitoring · Monitoring of AC or DC supplies · Monitoring of heating or lighting circuits Current monitoring, single-phase The ABB current monitoring relays CM-SRS.xx reliably monitor the occurrence of currents that exceed or fall below the selected threshold value. The functions overcurrent or undercurrent monitoring can be preselected. Single- and multifunction devices for the monitoring of direct or alternating currents from 3 mA to 15 A are available. Current window monitoring (Imin, Imax) The window monitoring relay CM-SFS.2x is available if the application requires the simultaneous monitoring of overand undercurrents. Voltage monitoring, single-phase The ABB voltage monitoring relays CM-SRS.xx are used to monitor direct and alternating voltages within a range of 3-600 V. Over- or undervoltage detection can be preselected. Voltage window monitoring (Umin, Umax) For the simultaneous detection of over- and undervoltages, the window monitoring relay CM-EFS.2 can be used. 84 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase monitoring relays Operating controls -- Current monitoring relays Adjustment of the threshold value >I for overcurrent Adjustment of the tripping delay TV DIP switches A ON-delay B OFF-delay g Closed-circuit principle h Open-circuit principle f Latching function activated e Latching function not activated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts Adjustment of the threshold value <I for undercurrent Indication of operational states I: red LED over- / undercurrent R: yellow LED relay status U/T: green LED control supply voltage/timing Adjustment of the start-up delay TS ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase monitoring relays Operating controls -- Voltage monitoring relays Adjustment of the threshold value >U for overvoltage Adjustment of the tripping delay TV DIP switches A ON-delay B OFF-delay g Closed-circuit principle h Open-circuit principle f Latching function activated e Latching function not activated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts 85 Adjustment of the threshold value <U for undervoltage Indication of operational states U: red LED over- / undervoltage R: yellow LED relay status U/T: green LED control supply voltage/timing Adjustment of the measuring range 86 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase current monitoring relays Selection table CM-SFS.22S 1SVR730760R0500 CM-SFS.21P 1SVR740760R0400 CM-SFS.21S 1SVR730760R0400 CM-SRS.M2S 1SVR730840R0700 CM-SRS.M1P 1SVR740840R0600 CM-SRS.M1S 1SVR730840R0600 CM-SRS.22S 1SVR730841R1500 CM-SRS.22S 1SVR730841R0500 CM-SRS.22S 1SVR730840R0500 CM-SRS.21P 1SVR740841R1400 CM-SRS.21S 1SVR730841R1400 CM-SRS.21P 1SVR740841R0400 CM-SRS.21S 1SVR730841R0400 CM-SRS.21P 1SVR740840R0400 CM-SRS.21S 1SVR730840R0400 CM-SRS.12S 1SVR730841R1300 CM-SRS.12S 1SVR730841R0300 CM-SRS.12S 1SVR730840R0300 CM-SRS.11P 1SVR740841R1200 CM-SRS.11S 1SVR730841R1200 CM-SRS.11P 1SVR740841R0200 CM-SRS.11S 1SVR730841R0200 CM-SRS.11P 1SVR740840R0200 CM-SRS.11S 1SVR730840R0200 Order number Type Rated control supply voltage Us 24 - 240 V AC/DC 110 - 130 V AC 220 - 240 V AC Measuring ranges AC/DC 3 - 30 mA 10 - 100 mA 0.1 - 1 A 0.3 - 1.5 A 1 - 5 A 3 - 15 A Monitoring function Over- or undercurrent Window current monitoring Latching Open-circuit or closed-circuit principle Timing functions for tripping delay ON-delay, 0.1 - 30 s ON- or OFF-delay, 0.1 - 30 s Output c/o contact Connection type Push-in terminals Double-chamber cage connection terminals adj: adjustable sel: selectable JJ J JJ J JJJJJJ JJ J JJ J JJ J JJ J JJJJJJ JJJJJJ JJ JJ JJJJJJ JJJJJJ JJ JJ JJJJJJ JJJJJJ JJ JJ JJJ JJJ J J JJJ JJJ J J JJJ JJJ J J JJJJJJJJJJJJJJJJJJJJJ JJJ sel sel sel sel sel sel sel sel sel sel sel sel adj adj adj adj adj adj adj adj adj adj adj adj sel sel sel 111111111222222222222222 JJJ JJJ J J J J J JJJJ J J JJJJ JJ J ERC CATALOG MEASURING AND MONITORING REL AYS 87 -- Single-phase current monitoring relays Ordering details CM-SRS.22S CM-SFS.22P 2CDC 251 056 V0011 2CDC 251 054 V0011 Description The CM range current monitoring relays protect single-phase mains (DC or AC) from over- and undercurrent from 3 mA to 15 A. -- Ordering details Description Type See selection table CM-SRS.11S CM-SRS.11P CM-SRS.12S CM-SRS.21S CM-SRS.21P CM-SRS.22S S: screw connection P: push-in connection CM-SRS.M1S CM-SRS.M1P CM-SRS.M2S CM-SFS.21S CM-SFS.21P CM-SFS.22S Order code 1SVR730840R0200 1SVR730841R0200 1SVR730841R1200 1SVR740840R0200 1SVR740841R0200 1SVR740841R1200 1SVR730840R0300 1SVR730841R0300 1SVR730841R1300 1SVR730840R0400 1SVR730841R0400 1SVR730841R1400 1SVR740840R0400 1SVR740841R0400 1SVR740841R1400 1SVR730840R0500 1SVR730841R0500 1SVR730841R1500 1SVR730840R0600 1SVR740840R0600 1SVR730840R0700 1SVR730760R0400 1SVR740760R0400 1SVR730760R0500 Weight (1 pc) kg (lb) 0.145 (0.320) 0.161 (0.355) 0.161 (0.355) 0.137 (0.302) 0.153 (0.337) 0.153 (0.337) 0.137 (0.302) 0.168 (0.370) 0.168 (0.370) 0.152 (0.335) 0.179 (0.395) 0.179 (0.395) 0.141 (0.311) 0.168 (0.370) 0.168 (0.370) 0.144 (0.399) 0.181 (0.399) 0.181 (0.399) 0.153 (0.337) 0.142 (0.313) 0.155 (0.342) 0.150 (0.331) 0.139 (0.306) 0.158 (0.348) 88 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase voltage monitoring relays Selection table CM-EFS.2P 1SVR740750R0400 CM-EFS.2S 1SVR730750R0400 CM-ESS.MP 1SVR740830R0500 CM-ESS.MS 1SVR730830R0500 CM-ESS.2P 1SVR740831R1400 CM-ESS.2S 1SVR730831R1400 CM-ESS.2P 1SVR740831R0400 CM-ESS.2S 1SVR730831R0400 CM-ESS.2P 1SVR740830R0400 CM-ESS.2S 1SVR730830R0400 CM-ESS.1P 1SVR740831R1300 CM-ESS.1S 1SVR730831R1300 CM-ESS.1P 1SVR740831R0300 CM-ESS.1S 1SVR730831R0300 CM-ESS.1P 1SVR740830R0300 CM-ESS.1S 1SVR730830R0300 Order number Type Rated control supply voltage Us 24 - 240 V AC/DC 110 - 130 V AC 220 - 240 V AC Measuring ranges AC/DC 3 - 30 V 6 - 60 V 30 - 300 V 60 - 600 V Monitoring function Over- or undervoltage Windows voltage monitoring Latching Open-circuit or closed-circuit principle Timing functions for tripping delay ON-delay, 0.1 - 30 s ON- or OFF-delay, 0.1 - 30 s Output c/o contact Connection type Push-in terminals Double-chamber cage connection terminals adj: adjustable sel: selectable JJ JJ JJJJ JJ JJ JJ JJ JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJ JJ sel sel sel sel sel sel sel sel adj adj adj adj adj adj adj adj sel sel 1111112222222222 JJJJJJJJ JJJJJJJJ ERC CATALOG MEASURING AND MONITORING REL AYS 89 -- Single-phase voltage monitoring relays Ordering details CM-ESS.MP CM-EFS.2 2CDC 251 059 V0011 2CDC 251 060 V0011 Description The CM range voltage monitoring relays provide reliable monitoring of voltages, as well as the detection of phase loss in single-phase mains. -- Ordering details Description Type See selection table CM-ESS.1S CM-ESS.1P CM-ESS.2S CM-ESS.2P S: screw connection P: push-in connection CM-ESS.MS CM-ESS.MP CM-EFS.2S CM-EFS.2P Order code 1SVR730830R0300 1SVR730831R0300 1SVR730831R1300 1SVR740830R0300 1SVR740831R0300 1SVR740831R1300 1SVR730830R0400 1SVR730831R0400 1SVR730831R1400 1SVR740830R0400 1SVR740831R0400 1SVR740831R1400 1SVR730830R0500 1SVR740830R0500 1SVR730750R0400 1SVR740750R0400 Weight (1 pc) kg (lb) 0.135 (0.298) 0.164 (0.362) 0.164 (0.362) 0.126 (0.278) 0.155 (0.342) 0.155 (0.342) 0.153 (0.337) 0.181 (0.399) 0.181 (0.399) 0.142 (0.313) 0.170 (0.375) 0.170 (0.375) 0.154 (0.340) 0.143 (0.320) 0.157 (0.346) 0.146 (0.322) 90 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase current monitoring relays Technical data Type CM-SRS.1 CM-SRS.2 CM-SRS.M CM-SFS.2 Input circuit - Supply circuit A1-A2 Rated control supply voltage Us A1-A2 110-130 V AC A1-A2 220-240 V AC A1-A2 24-240 V AC/DC Rated control supply voltage Us tolerance -15...+10 % Rated frequency AC versions 50/60 Hz AC/DC versions 50/60 Hz or DC Current / power consumption see data sheets Power failure buffering time 20 ms Transient overvoltage protection Varistors Input circuit - Measuring circuit B1/B2/B3-C Monitoring function over- or undercurrent monitoring configurable over- and undercurrent monitoring Measuring method True RMS measuring principle Measuring inputs CM-SxS.x1 CM-SxS.x2 Terminal connection B1-C B2-C B3-C B1-C B2-C B3-C Measuring ranges AC/DC 3-30 mA 10-100 mA 0.1-1 A 0.3-1.5 A 1-5 A 3-15 A1) Input resistance 3.3 1 0.1 0.05 0.01 0.0025 Pulse overload 500 mA 1 A capacity t< 1 s 10 A 15 A 50 A 100 A Continuous capacity 50 mA 150 mA 1.5 A 2 A 7 A 17 A Threshold value(s) adjustable within the indicated measuring range Setting accuracy of threshold value 10 % of full-scale value Hysteresis related to the threshold value 3-30 % adjustable 5 % fixed Measuring signal frequency range DC / 15 Hz - 2 kHz Rated measuring signal frequency range DC / 50-60 Hz Maximum response time AC: 80 ms / DC: 120 ms Accuracy within the control supply voltage tolerance U m 0.5 % Accuracy within the temperature range U m 0.06 % / °C Timing circuit Start-up delay TS none 0 or 0.1-30 s adjustable Tripping delay TV none 0 or 0.1-30 s adjustable Repeat accuracy (constant parameters) w0.07 % of full scale Accuracy within the control supply voltage tolerance - t 0.5 % Accuracy within the temperature range - t 0.06 % / °C Indication of operational states Control supply voltage U/T: green LED V: control supply voltage applied, X: start-up delay TS active, W: tripping delay TV active Measured value I: red LED V: overcurrent, W: undercurrent Relay status R: yellow LED V: relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function ERC CATALOG MEASURING AND MONITORING REL AYS 91 -- Single-phase current monitoring relays Technical data Type CM-SRS.1 CM-SRS.2 CM-SRS.M CM-SFS.2 Output circuits 11(15)-12(16)/14(18), 21(25)-22(26)/24(28) - Relays Kind of output 1 c/o contact 2 c/o contacts 1x2 c/o contacts or 2x1 c/o contact configurable Operating principle open-circuit principle 2) open- or closed-circuit principle configurable2) Contact material AgNi Minimum switching voltage / minimum switching current 24 V / 10 mA Maximum switching voltage / maximum switching current 250 V AC / 4 A AC Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC rating (UL 508) Utilization category B 300 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power 3600/360 VA (Make/Break) at B 300 Mechanical lifetime 30x106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1x106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting 10 A fast-acting 6 A fast-acting (1) In case of measured currents > 10 A, lateral spacing has to be min. 10 mm (2) Open-circuit principle: output relay energizes if the measured value exceeds b / falls below a the adjusted threshold value Closed-circuit principle: output relay de-energizes if measured value exceeds b / falls below a the adjusted threshold value 92 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase current monitoring relays Technical data Type CM-SRS.1 CM-SRS.2 CM-SRS.M CM-SFS.2 General data MTBF on request Duty cycle 100% Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units 10 mm (0.39 in) at measured current > 10 A Material of housing UL 94 V-0 Degree of protection housing / terminals IP50 / IP20 Electrical connection Connecting capacity Screw connection technology fine-strand with(out) wire end 1 x 0.5-2.5 mm² (1 x 20-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (7.08 lb.in) - Environmental data Ambient temperature range operation / -20...+60 °C / storage -40...+85 °C Damp heat (IEC 60068-2-30) 55 °C, 6 cycles Vibration (sinusoidal) class 2 Shock class 2 Isolation data Rated insulation voltage supply / 600 V measuring circuit / output supply / output 1/2 250 V Rated impulse withstand voltage Uimp supply /measuring 6 kV 1.2/50 s circuit / output supply / output 1/2 4 kV 1.2/50 s Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 3 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 electrical fast transient / burst IEC/EN 61000-4-4 level 3 surge IEC/EN 61000-4-5 level 3 conducted disturbances, induced by IEC/EN 61000-4-6 level 3 radio-frequency fields Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22; EN 55022 Class B high-frequency conducted IEC/CISPR 22; EN 55022 Class B ERC CATALOG MEASURING AND MONITORING REL AYS 93 -- Single-phase voltage monitoring relays Technical data Type Input circuit - Supply circuit Rated control supply voltage Us Rated control supply voltage Us tolerance Rated frequency Current / power consumption Power failure buffering time Transient overvoltage protection Input circuit - Measuring circuit Monitoring function CM-ESS.1 CM-ESS.2 A1-A2 A1-A2 110-130 V AC A1-A2 220-240 V AC A1-A2 24-240 V AC/DC -15...+10 % AC versions 50/60 Hz AC/DC versions 50/60 Hz or DC see data sheet 20 ms varistors B-C over- or undervoltage monitoring configurable CM-ESS.M Measuring method True RMS measuring principle Measuring inputs CM-ExS Terminal connection B-C B-C B-C Measuring range AC/DC 3-30 V 6-60 V 30-300 V Input resistance 600 kq 600 kq 600 kq Pulse overload capacity 800 V t < 1 s 800 V 800 V Continuous capacity 660 V 660 V 660 V Threshold value(s) adjustable within the indicated measuring range Tolerance of the adjusted threshold value 10 % of full-scale value Hysteresis related to the threshold value 3-30 % adjustable Measuring signal frequency range DC / 15 Hz - 2 kHz Rated measuring signal frequency range DC / 50-60 Hz Maximum response time AC: 80 ms / DC: 120 ms Accuracy within the control supply voltage tolerance U m 0.5 % Accuracy within the temperature range U m 0.06 % / °C Transient overvoltage protection Varistors Timing circuit Delay time TV none 0 or 0.1-30 s adjustable Repeat accuracy (constant parameters) w0.07 % of full scale value Accuracy within the control supply voltage tolerance - t m 0.5 % Accuracy within the temperature range - t m 0.06 % / °C Indication of operational states Control supply voltage U/T: green LED V: control supply voltage applied W: tripping delay TV active Measured value U: red LED V: overvoltage, W: undervoltage Relay status R: yellow LED V: relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function CM-EFS.2 over- and under voltage monitoring configurable B-C 60-600 V 600 kq 800 V 660 V 5 % fixed 94 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase voltage monitoring relays Technical data Type Output circuits Kind of output CM-ESS.1 1 c/o contact CM-ESS.2 2 c/o contacts Operating principle open-circuit principle1) Contact material AgNi Minimum switching voltage / minimum switching current 24 V / 10 mA Maximum switching voltage / maximum switching current 250 V AC / 4 A AC Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC rating (UL 508) Utilization category B 300 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power 3600/360 VA (Make/Break) at B 300 Mechanical lifetime 30x106 switching cycles Electrical lifetime AC-12, 230 V, 4 A 0.1x106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting 10 A fast-acting CM-ESS.M CM-EFS.2 1x2 c/o contacts or 2x1 c/o contact configurable open- or closed-circuit principle configurable1) 6 A fast-acting ERC CATALOG MEASURING AND MONITORING REL AYS 95 -- Single-phase voltage monitoring relays Technical data Type CM-ESS.1 CM-ESS.2 CM-ESS.M CM-EFS.2 General data MTBF on request Duty cycle 100% Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical / horizontal not necessary / not necessary Material of housing UL 94 V-0 Degree of protection housing / terminals IP50 / IP20 Environmental data Ambient temperature ranges operation -20...+60 °C storage -40...+85 °C Damp heat, cyclic (IEC/EN 60068-2-30) 55 °C, 6 cycle Vibration, sinusoidal class 2 Shock class 2 Electrical connection Wire size Screw connection technology Easy Connect Technology (Push-in) fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm² (1 x 18-14 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (7.08 lb.in) - Isolation data Rated insulation voltage supply / measuring 600 V circuit / output supply / output 1/2 250 V Rated impulse withstand voltage Uimp supply / measuring 6 kV 1.2/50 s circuit / output supply / output 1/2 4 kV 1.2/50 s Pollution degree 3 Overvoltage category III Standards / Directives Product standard IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 3 radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 electrical fast transient / burst IEC/EN 61000-4-4 level 3 surge IEC/EN 61000-4-5 level 3 conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3 Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22; EN 55022 class B high-frequency conducted IEC/CISPR 22; EN 55022 class B 1) Open-circuit principle: output relay energizes if the measured value exceeds d / falls below c the adjusted threshold value Closed-circuit principle: output relay de-energizes if measured value exceeds d / falls below c the adjusted threshold value 96 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase current monitoring relays Technical diagrams -- Connection diagram 2CDC252205F0005 2CDC 252 205 F0005 2CDC252204F0005 2CDC 252 204 F0005 CM-SRS.1x, CM-SRS.2x A1 1115 C B1 B2 B3 B1 B2 B3 1115 C CM-SRS.Mx A1 1115 B1 B2 B1 B2 B3 1115 2125 B3 2125 C 2CDC252204F0005 2CDC 252 205 F0005 A1 A2 1216 1418 1418 1216 A2 A1 1115 B1 B2 B1 B2 B3 1115 2125 B3 2125 C A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 Control supply voltage B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A B2-C Measuring range 2: 10-100 mA or 1-5 A B3-C Measuring range 3: 0.1-1 A or 3-15 A 1115-1216/1418 Output contacts 2125-2226/2428 open-circuit principle A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 Control supply voltage B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A B2-C Measuring range 2: 10-100 mA or 1-5 A B3-C Measuring range 3: 0.1-1 A or 3-15 A 1115-1216/1418 Output contacts 2125-2226/2428 open- or closed circuit principle 2CDC252205F0005 2CDC 252 205 F0005 CM-SFS.2x A1 1115 B1 B2 B1 B2 B3 1115 2125 B3 2125 C A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 Control supply voltage B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A B2-C Measuring range 2: 10-100 mA or 1-5 A B3-C Measuring range 3: 0.1-1 A or 3-15 A 1115-1216/1418 2125-2226/2428 Output contacts open- or closed circuit principle 2CDC252205F0005 2CDC 252 205 F0005 CM-SRS.2x A1 1115 B1 B2 B1 B2 B3 1115 2125 B3 2125 C A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 Control supply voltage B1-C Measuring range 1: 3-30 mA or 0.3-1.5 A B2-C Measuring range 2: 10-100 mA or 1-5 A B3-C Measuring range 3: 0.1-1 A or 3-15 A 1115-1216/1418 2125-2226/2428 Output contacts open- or closed circuit principle -- DIP switch functions CM-SRS.1x, CM-SRS.2x 1 ON Undercurrent monitoring OFF Overcurrent monitoring OFF = Default CM-SRS.Mx Position 4 ON 3 2 1 closed I OFF open I 1 ON OFF Undercurrent monitoring Overcurrent monitoring 2 ON OFF Closed-circuit principle Open-circuit principle 3 ON OFF Latching function activated Latching function not activated OFF = Default CM-SFS.2x Position 4 3 2 1 ON 2x1 c/o closed OFF 1x2 c/o open 1 ON OFF-delay OFF ON-delay 2 ON Closed-circuit principle OFF Open-circuit principle 3 ON Latching function activated OFF Latching function not activated 4 ON 2x1 c/o contact OFF 1x2 c/o contacts OFF = Default CM-SRS.2x Position 4 ON 3 2 1 closed I OFF open I 1 ON Undercurrent monitoring OFF Overcurrent monitoring 2 ON Closed-circuit principle OFF Open-circuit principle 3 ON Latching function activated OFF Latching function not activated OFF = Default 22CCDDCC252252272F7020F005005 22CCDDCC2255227237F30F0000505 22CCDDCC2522527247F40F0000505 22CCDDCC25225227327F300F005005 ERC CATALOG MEASURING AND MONITORING REL AYS 97 -- Single-phase voltage monitoring relays Technical diagrams -- Connection diagram 2CDC252207F0005 2CDC 252 207 F0005 2CDC252206F0005 2CDC 252 206 F0005 CM-ESS.1, CM-ESS.2 A1 1115 C B B 1115 C CM-EFS.2 A1 1115 2125 B B 1115 2125 C 2CDC252207F0005 2CDC 252 207 F0005 A1 A2 1216 1418 1418 1216 A2 A1 1115 2125 B B 1115 2125 C A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 B-C Control supply voltage Measuring ranges AC/DC: 3-30 V; 6-60 V; 30-300 V; 60-600 V A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 B-C Control supply voltage Measuring ranges AC/DC: 3-30 V; 6-60 V; 30-300 V; 60-600 V 1115-1216/1418 Output contacts 2125-2226/2428 open- or closed circuit principle 1115-1216/1418 2125-2226/2428 Output contacts open-circuit principle 2CDC252207F0005 2CDC 252 207 F0005 CM-ESS.M A1 1115 2125 B B 1115 2125 C A1 A2 1216 1418 2226 2428 1418 1216 C 2428 2226 A2 A1-A2 B-C 1115-1216/1418 2125-2226/2428 Control supply voltage Measuring ranges AC/DC: 3-30 V; 6-60 V 30-300 V; 60-600 V Output contacts open- or closed circuit principle -- DIP switch functions CM-ESS.1, CM-ESS.2 1 ON Undervoltage monitoring OFF Overvoltage monitoring OFF = Default CM-EFS.2 Position 4 3 2 1 ON 2x1 c/o closed OFF 1x2 c/o open CM-ESS.M Position 4 ON 3 2 1 closed V OFF open V 1 ON ON-delay OFF OFF-delay 2 ON Closed-circuit principle OFF Open-circuit principle 3 ON Latching function activated OFF Latching function not activated 4 ON 2x1 c/o contact OFF 1x2 c/o contacts OFF = Default 1 ON OFF Undervoltage monitoring Overvoltage monitoring 2 ON OFF Closed-circuit principle Open-circuit principle 3 ON OFF Latching function activated Latching function not activated OFF = Default 2CCDDCC2522527257F500F05005 22CCDDCC2522522742F7040F005005 22CCDDCC25225227267F600F00505 98 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase monitoring relays Function diagrams CM-SRS.1x and CM-SRS.2x If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-SRS.1x - immediately, on the CM-SRS.2x - after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s). The hysteresis is adjustable within a range of 3-30 % of the threshold value. 2CDC 252 208 F0205 CM-SRS.1x Overcurrent monitoring b A1-A2 Threshold Hysteresis Measured value 11-14 (15-18) 11-12 (15-16) green LED red LED yellow LED Undercurrent monitoring a A1-A2 Measured value Hysteresis Threshold 11-14 (15-18) 11-12 (15-16) green LED red LED yellow LED 2CDC 252 209 F0205 CM-SRS.2x Overcurrent monitoring b A1-A2 Threshold Hysteresis Measured value TV < TV 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Undercurrent monitoring a A1-A2 Measured value TV < TV Hysteresis Threshold 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 211 F0205 2CDC 252 210 F0205 Further function diagrams see data sheet. ERC CATALOG MEASURING AND MONITORING REL AYS 99 -- Single-phase monitoring relays Function diagrams CM-SRS.Mx If the measured value exceeds resp. drops below the adjusted threshold value before the set start-up delay TS is complete, the output relays do not change their actual state. If the measured value exceeds resp. drops below the adjusted threshold value when TS is complete, the tripping delay TV starts. If TV is complete and the measured value is still exceeding resp. below the threshold value plus resp. minus the set hysteresis, the output relays energize h / de-energize g. If the measured value exceeds resp. drops below the threshold value minus resp. plus the set hysteresis and the latching function is not activated e, the output relays de-energize h / energize g. With activated latching function f the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. The hysteresis is adjustable within a range of 3-30 % of the threshold value. 2CDC 252 212 F0205 Overcurrent monitoring b with latching f A1-A2 Threshold Hysteresis Measured value Open-circuit principle open TS 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Reset TV TS < TV Undercurrent monitoring b with latching f A1-A2 Measured value Hysteresis Threshold Open-circuit principle open TS 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Reset TV TS < TV 2CDC 252 215 F0205 2CDC 252 214 F0205 Overcurrent monitoring b without latching e A1-A2 Threshold Hysteresis Measured value Open-circuit principle open TS TV < TV 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Undercurrent monitoring a without latching e A1-A2 Measured value Hysteresis Threshold Open-circuit principle open TS TV 11-14 (15-18) < TV 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 213 F0205 Further function diagrams see data sheet. 100 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase monitoring relays Function diagrams CM-SFS.2x Current window monitoring 1x2 c/o contact j ON-delayed A without latching f A1-A2 Thresholdmax Hysteresis Measured value TS TV Hysteresis Thresholdmin < TV Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 216 F0205 ON-delayed A current window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value before the set start-up delay TS is complete, the output relays do not change their actual state. If the measured value exceeds resp. drops below the adjusted threshold value when TS is complete, the tripping delay TV starts when A is configured. If TV is complete and the measured value is still exceeding resp. below the threshold value minus resp. plus the fixed hysteresis (5%), the output relays energize h /de-energize g. If the measured value exceeds resp. drops below the threshold value plus resp. minus the hysteresis and the latching function is not activated f, the output relays de-energize h / energize g. With activated latching function e the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays r emain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. Current window monitoring 1x2 c/o contact j OFF-delayed B without latching e A1-A2 Thresholdmax Hysteresis Measured value TS TV TV Hysteresis Thresholdmin Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 217 F0205 OFF-delayed B current window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value when the set start-up delay TS is complete, the output relays energize h / de-energize g, when B is configured, and remain in this position during the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the fixed hysteresis (5%) and the latching function is not activated e, the tripping delay TV starts. After completion of TV, the output relays de-energize h / energize g, provided that the latching function is not activated e. With activated latching function f the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. When i is adjusted on the device, the functionality is equivalent to the one described above. In this case, instead of both output relays, only one output relay each will be switched. ">I" = 1115-1216/1418 ; "<I" = 2125-2226/2428 Further function diagrams see data sheet. ERC CATALOG MEASURING AND MONITORING REL AYS 101 -- Single-phase monitoring relays Function diagrams CM-ESS.1x and CM-ESS.2x Depending on the configuration, the voltage monitoring relays CM-ESS.1 and CM-ESS.2 can be used for over- d or undervoltage monitoring c in single-phase AC and/or DC systems. The voltage to be monitored (measured value) is applied to terminals B-C. The devices work according to the open-circuit principle. If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-ESS.1 - immediately, on the CM-ESS.2 - after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s). The hysteresis is adjustable within a range of 3-30 % of the threshold value. CM-ESS.1x CM-ESS.2x Overvoltage monitoring d A1-A2 Threshold Hysteresis Measured value 11-14 (15-18) 11-12 (15-16) green LED red LED yellow LED Undervoltage monitoring c A1-A2 Measured value Hysteresis Threshold 11-14 (15-18) 11-12 (15-16) green LED red LED yellow LED Overvoltage monitoring d A1-A2 Threshold Hysteresis Measured value TV 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Undervoltage monitoring c A1-A2 Measured value TV Hysteresis Threshold 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED < TV < TV 2CDC 252 211 F0205 2CDC 252 210 F0205 2CDC 252 209 F0205 2CDC 252 208 F0205 Further function diagrams see data sheet. 102 ERC CATALOG MEASURING AND MONITORING REL AYS -- Single-phase monitoring relays Function diagrams CM-ESS.Mx If the measured value exceeds resp. drops below the adjusted threshold value, the tripping delay TV starts. If TV is complete and the measured value is still exceeding resp. below the threshold value plus resp. minus the set hysteresis, the output relays energize h / de-energize g. If the measured value exceeds resp. drops below the threshold value plus resp. minus the set hysteresis and the latching function is not activated e, the output relays de-energize h / energize g. With activated latching function f the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. The hysteresis is adjustable within a range of 3-30 % of the threshold value. 2CDC 252 230 F0205 Overvoltage monitoring d without latching e A1-A2 Threshold Hysteresis Measured value Open-circuit principle open < TV TV < TV 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Undervoltage monitoring c without latching e A1-A2 Measured value Hysteresis Threshold Open-circuit principle open < TV TV 11-14 (15-18) < TV 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 229 F0205 2CDC 252 228 F0205 Overvoltage monitoring d with latching f A1-A2 Threshold Reset Hysteresis Measured value Open-circuit principle open < TV TV < TV 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Undervoltage monitoring c without latching f A1-A2 Measured value Hysteresis Threshold Reset Open-circuit principle open < TV TV 11-14 (15-18) < TV 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 231 F0205 Further function diagrams see data sheet. ERC CATALOG MEASURING AND MONITORING REL AYS 103 -- Single-phase monitoring relays Function diagrams CM-EFS.2x Voltage window monitoring 1x2 c/o contact j ON-delayed A without latching e A1-A2 Thresholdmax Hysteresis Measured value < TV TV Hysteresis Thresholdmin < TV Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Voltage window monitoring 1x2 c/o contact j OFF-delayed B without latching e A1-A2 Thresholdmax Hysteresis Measured value TV TV Hysteresis Thresholdmin Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26) green LED red LED yellow LED 2CDC 252 233 F0205 2CDC 252 232 F0205 ON-delayed A voltage window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value, the tripping delay TV starts, when A is configured. If TV is complete and the measured value is still exceeding resp. below the threshold value minus resp. plus the fixed hysteresis (5%), the output relays energize h / de-energize g. If the measured value exceeds resp. drops below the threshold value plus resp. minus the hysteresis and the latching function is not activated e, the output relays de-energize h / energize g. With activated latching function e the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. OFF-delayed B voltage window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value, the output relays energize h / de-energize g, when B is configured, and remain in this position during the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the fixed hysteresis (5%) and the latching function is not activated e, the tripping delay TV starts. After completion of TV, the output relays de-energize h / energize g, provided that the latching function is not activated e. With activated latching function e the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. When i is adjusted on the device, the functionality is equivalent to the one described above. In this case, instead of both output relays, only one output relay each will be switched. ">U" = 1115-1216/1418 ; "<U" = 2125-2226/2428 Further function diagrams see data sheet. 104 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 105 -- Three-phase monitoring relays Table of contents 106 Benefits and advantages 109 Function 110 Operating controls 112 Selection table - singlefunctional 113 Ordering details - singlefunctional 114 Selection table - multifunctional 115 Ordering details - multifunctional 116 Technical data 127 Technical diagrams 129 Function diagrams 106 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Benefits and advantages For the monitoring of voltages in a three-phase system or network, ABB's CM range contains a wide selection of powerful and compact devices. This product range includes voltage monitoring relays for phase sequence, phase loss, unbalance and monitoring of over- and under voltage from 160 V to 820 V. Continuous operation Read the status of the relay at a glance: clear visualization of the device status via LEDs. Easy to adjust with rotary wheels and variants with push-in terminals make a quick and easy installation and setting possible. Reliable in harsh conditions All relays work reliably in environments with low temperatures down to -25°C. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable no matter the environment temperature but is also durable to shock and vibration. Save time as retightening is no longer needed and enhance the reliability and safety not only for the equipment. Easy installation Like all devices from the measuring and monitoring portfolio, the three-phase monitoring relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. For further configuration options, additional settings can be made via dip-switches, offering the flexibility to configure, for example, the working principle of the relays and the output configuration. The device can be set up before installation in the application and easy adjustments during the process are possible. ERC CATALOG MEASURING AND MONITORING REL AYS 107 -- Three-phase monitoring relays Benefits and advantages Characteristics · True RMS (TRMS) measuring principle · Device for the use in mains with a frequency of 45-440 Hz and where harmonics are to be expected1) · Adjustable phase unbalance threshold value · Adjustable ON-delay/OFF-delay time · Powered by the measuring circuit · 1 n/o contact, 1 or 2 c/o contacts · LEDs for the indication of operational states · Multifunctional and singlefunctional devices · Phase failure detection · Phase sequence monitoring · Over- and undervoltage monitoring (fixed or adjustable) · Wide-range operating voltage guarantees world-wide operation · Various approvals and marks (1) devices CM-MPS.23 and CM-MPS.43 Applications · Control for connection of moving equipment (e.g. air conditioning compressors, refrigerated trucks and containers, and cranes) · Control against reverse motor operation (lifting, handling, elevators, escalators, etc.) · Control of sensitive three-phase supplies · Overheating of the motor due to asymmetrical voltage · Protection of a plant against destruction due to overvoltage · Direction of rotation of the drive 108 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays have many functions to protect various applications ERC CATALOG MEASURING AND MONITORING REL AYS 109 -- Three-phase monitoring relays Function Phase unbalance monitoring If the supply by the three-phase system is unbalanced due to an uneven distribution of the load, the motor will convert a part of the energy into reactive power. This energy gets lost unexploited; also the motor is exposed to higher thermal stress. Other thermal protection devices fail to detect continuing unbalances, which can lead to damage or destruction of the motor. The CM range three-phase monitors with phase unbalance monitoring can reliably detect this critical situation. Phase sequence Changing the phase sequence during operation or a wrong phase sequence prior to startup causes a change of the rotational direction of the connected device. Generators, pumps or fans rotate in the wrong direction and the installation is no longer working properly. In particular, for moveable equipment, such as construction machinery, phase sequence detection prior to the startup process is highly reasonable. Phase loss In case of phase loss, undefined stats of the installation are likely to occur; e.g. the startup process of motors is disturbed. All three-phase monitors of the ABB CM range detect a phase loss as soon as the voltage of one phase drops below 60 % of its nominal value. Voltage monitoring All electric devices can be damaged when operated continuously in a network with out-of-range voltages. For example, safe starting is not ensured in case of undervoltage. Also, the switching state of a contactor is not clearly defined when operated in a "forbidden" voltage range. This can lead to undefined states of the installation and cause damage or destruction of valuable parts. Selectable phase sequence monitoring The phase sequence monitoring can be switched off by means of a rotary switch or a DIP switch. This enables monitoring of three-phase mains where phase sequence is not relevant for the application, for example in case of motors with forward and reverse rotation, heating applications, etc. Automatic phase sequence correction The automatic phase sequence correction is activated by means of a DIP switch. With activated phase sequence correction, it is e nsured that for any non-fixed or portable equipment, e.g. c onstruction machinery, the correct phase sequence is always applied to the input terminals of the load. For details regarding the wiring, please see function description / diagrams. 110 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Operating controls -- S-range housing Adjustment of the threshold value >U for overvoltage Adjustment of the threshold value Asymetry for phase unbalance DIP switches A ON-delay B OFF-delay l Phase sequence monitoring deactivated k Phase sequence monitoring activated m Phase sequence correction activated n Phase sequence correction deactivated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts Adjustment of the threshold value <U for undervoltage Indication of operational states R/T: red LED Relay status / timing F1: yellow LED Fault message F2: yellow LED Fault message Adjustment of the tripping delay T ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Operating controls -- N-range housing Adjustment of the threshold value >U for overvoltage Adjustment of the threshold value <U for undervoltage DIP switches A ON-delay B OFF-delay l Phase sequence monitoring deactivated k Phase sequence monitoring activated m Phase sequence correction activated n Phase sequence correction deactivated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts 111 Adjustment of the threshold value Asymmetry for phase unbalance Indication of operational states R/T: red LED Relay status / timing F1: yellow LED Fault message F2: yellow LED Fault message Adjustment of the tripping delay T 112 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Selection table - singlefunctional CM-PAS.41P 1SVR740774R3300 CM-PAS.41S 1SVR730774R3300 CM-PAS.31P 1SVR740774R1300 CM-PAS.31S 1SVR730774R1300 CM-PVS.81P 1SVR740794R2300 CM-PVS.81S 1SVR730794R2300 CM-PVS.41P 1SVR740794R3300 CM-PVS.41S 1SVR730794R3300 CM-PVS.31P 1SVR740794R1300 CM-PVS.31S 1SVR730794R1300 CM-PSS.41P 1SVR740784R3300 CM-PSS.41S 1SVR730784R3300 CM-PSS.31P 1SVR740784R2300 CM-PSS.31S 1SVR730784R2300 CM-PFS.P 1SVR740824R9300 CM-PFS.S 1SVR730824R9300 CM-PFE.2 1SVR550826R9100 1SVR550824R9100 1SVR550871R9500 1SVR550870R9400 1SVR550882R9500 Order number 1SVR550881R9400 CM-PFE CM-PVE CM-PVE CM-PBE Type CM-PBE Rated control supply voltage Us Phase to phase 160-300 V AC 200-400 V AC 200-500 V AC 208-440 V AC 300-500 V AC 320-460 V AC 380 V AC 380-440 V AC 400 V AC Phase to neutral 185-265 V AC 220-240 V AC Rated frequency 50/60 Hz Suitable for monitoring Single-phase mains Three-phase mains Monitoring function Phase failure Phase sequence Overvoltage Undervoltage Unbalance Neutral1) Thresholds adjustable (adj) or fixed (fix) Timing functions for tripping delay ON delay On and OFF delay Connection type Push-in terminals Double-chamber cage connection terminals JJ JJ JJ JJJ J JJ JJ JJ JJ JJ JJ J J JJJJJJJJJJJJJJJJJJJJJJ JJ JJJJJJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJJJJ J J J J sel sel sel sel sel sel sel sel sel sel J J J J JJ JJJJJJJJJJ JJ JJJJJJJJJJ JJJJ JJ fix fix fix fix fix fix fix fix fix fix fix fix fix fix adj adj adj adj adj adj adj adj fix fix sel sel sel sel fix fix fix fix fix fix adj adj adj adj adj adj adj adj adj adj JJJJJJJ JJJJJJJ (1) The external conductor voltage towards the neutral conductor is measured. adj: adjustable sel: selectable fix: fixed ERC CATALOG MEASURING AND MONITORING REL AYS 113 -- Three-phase monitoring relays Ordering details - singlefunctional CM-PBE CM-PSS.41P CM-PAS.31P 2CDC 251 064 V0011 2CDC 251 063 V0011 2CDC 251 064 V0011 Description The three-phase monitoring relays are designed for use in three-phase mains for monitoring the phase parameters like phase sequence, phase failure, over- and undervoltage, as well as phase unbalance. -- Ordering details Characteristics Type See selection table CM-PBE CM-PBE CM-PVE CM-PVE CM-PFE CM-PFE.2 Order code 1SVR550881R9400 1SVR550882R9500 1SVR550870R9400 1SVR550871R9500 1SVR550824R9100 1SVR550826R9100 Weight (1 pc) kg (lb) 0.08 (0.17) 0.08 (0.17) 0.08 (0.17) 0.08 (0.17) 0.08 (0.17) 0.067 (0.147) Characteristics Type See selection table S: screw connection P: push-in connection CM-PFS.S CM-PFS.P CM-PSS.31S CM-PSS.31P CM-PSS.41S CM-PSS.41P CM-PVS.31S CM-PVS.31P CM-PVS.41S CM-PVS.41P CM-PVS.81S CM-PVS.81P CM-PAS.31S CM-PAS.31P CM-PAS.41S CM-PAS.41P Order code 1SVR730824R9300 1SVR740824R9300 1SVR730784R2300 1SVR740784R2300 1SVR730784R3300 1SVR740784R3300 1SVR730794R1300 1SVR740794R1300 1SVR730794R3300 1SVR740794R3300 1SVR730794R2300 1SVR740794R2300 1SVR730774R1300 1SVR740774R1300 1SVR730774R3300 1SVR740774R3300 Weight (1 pc) kg (lb) 0.127 (0.280) 0.119 (0.262) 0.132 (0.291) 0.123 (0.271) 0.132 (0.291) 0.123 (0.271) 0.141 (0.311) 0.132 (0.291) 0.139 (0.306) 0.131 (0.289) 0.136 (0.300) 0.128 (0.282) 0.133 (0.293) 0.124 (0.273) 0.132 (0.291) 0.123 (0.271) 114 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Selection table - multifunctional CM-MPN.72P 1SVR760489R8300 CM-MPN.72S 1SVR750489R8300 CM-MPN.62P 1SVR760488R8300 CM-MPN.62S 1SVR750488R8300 CM-MPN.52P 1SVR760487R8300 CM-MPN.52S 1SVR750487R8300 CM-MPS.43P 1SVR740884R4300 CM-MPS.43S 1SVR730884R4300 CM-MPS.23P 1SVR740885R4300 CM-MPS.23S 1SVR730885R4300 CM-MPS.41P 1SVR740884R3300 CM-MPS.41S 1SVR730884R3300 CM-MPS.31P 1SVR740884R1300 CM-MPS.31S 1SVR730884R1300 CM-MPS.21P 1SVR740885R3300 CM-MPS.21S 1SVR730885R3300 CM-MPS.11P 1SVR740885R1300 CM-MPS.11S 1SVR730885R1300 Order number Type Rated control supply voltage Us Phase to phase 160-300 V AC 300-500 V AC 350-580 V AC 450-720 V AC 530-820 V AC Phase to neutral 90-170 V AC 180-280 V AC Rated frequency 50/60 Hz 50/60/400 Hz Suitable for monitoring Mains with harmonic content Single-phase mains Three-phase mains Monitoring function Phase failure Phase sequence Automatic phase sequence correction Overvoltage Undervoltage Unbalance Interrupted neutral monitoring 1) Thresholds Adjustable (adj) Timing functions for tripping delay On- or OFF delay Connection type Push-in terminals Double-chamber cage connection terminals JJ JJ JJ JJ JJ JJ JJ JJ JJ JJJJJJJJ JJJJJJ JJJJ JJJJ JJJJ JJ JJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJ sel sel sel sel sel sel sel sel adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj JJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJ JJJJ JJ adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj JJJJJJJJJ JJJJJJJJJ 1) The relay detects by means of a phase unbalance the interruption of the neutral conductor. The external conductor voltage towards the neutral conductor is measured too. adj: adjustable sel: selectable ERC CATALOG MEASURING AND MONITORING REL AYS 115 -- Three-phase monitoring relays Ordering details - multifunctional CM-MPS.23P CM-MPN.52P 2CDC 251 065 V0011 2CDC 251 062 V0011 Description The three-phase monitoring relays are designed for use in three-phase mains for monitoring the phase parameters, such as phase sequence, phase failure, over- and undervoltage, as well as phase unbalance. -- Ordering details Characteristics Type See selection table S: screw connection P: push-in connection CM-MPS.11S CM-MPS.11P CM-MPS.21S CM-MPS.21P CM-MPS.31S CM-MPS.31P CM-MPS.41S CM-MPS.41P CM-MPS.23S CM-MPS.23P CM-MPS.43S CM-MPS.43P CM-MPN.52S CM-MPN.52P CM-MPN.62S CM-MPN.62P CM-MPN.72S CM-MPN.72P Order code 1SVR730885R1300 1SVR740885R1300 1SVR730885R3300 1SVR740885R3300 1SVR730884R1300 1SVR740884R1300 1SVR730884R3300 1SVR740884R3300 1SVR730885R4300 1SVR740885R4300 1SVR730884R4300 1SVR740884R4300 1SVR750487R8300 1SVR760487R8300 1SVR750488R8300 1SVR760488R8300 1SVR750489R8300 1SVR760489R8300 Weight (1 pc) kg (lb) 0.148 (0.326) 0.137 (0.302) 0.146 (0.322) 0.135 (0.298) 0.142 (0.313) 0.133 (0.293) 0.140 (0.309) 0.132 (0.291) 0.149 (0.328) 0.138 (0.304) 0.148 (0.327) 0.137 (0.302) 0.230 (0.507) 0.226 (0.498) 0.229 (0.505) 0.225 (0.496) 0.224 (0.494) 0.220 (0.485) 116 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical data Type CM-PBE1) CM-PBE CM-PVE1) CM-PVE CM-PFE CM-PFE.2 Input circuit - supply circuit L1-L2-L3-N L1-L2-L3 L1-L2-L3-N L1-L2-L3 Rated control supply voltage US = measuring voltage 3x380440 V AC, 220-240 V AC 3x380440 V AC 3x320460 V AC, 185-265 V AC 3x320460 V AC 3x208440 V AC 3x200500 V AC Power consumption 13 mA / 9 VA Rated control supply voltage US tolerance Rated frequency -15...+15 % 50/60 Hz -15...+10 % 50/60 Hz (-10...+10 %) 50/60 Hz Duty time 100 % Input circuit - measuring circuit Monitoring functions Measuring ranges L1-L2-L3-N L1-L2-L3 J phase failure J phase sequence - - over- / undervoltage - - neutral J - 3x380-440 3x380V AC, 220- 440 V AC 240 V AC L1-L2-L3-N L1-L2-L3 J J - - J J J - 3x320460 V AC, 185-265 V AC 3x320460 V AC J J - - 3x208440 V AC J J - - 3x200500 V AC Thresholds Umin 0.6 x UN fixed 185 V / 320 V fixed 320 V 0.6 x UN Umax - fixed fixed - 265 V / 460 V 460 V Hysteresis related to the threshold value Measuring voltage frequency fixed 5 % fixed 5 % (release value = 0.65 x UN) 50/60 Hz (-10 %...+10 %) 50/60 Hz Response time 40 ms 80 ms 500 ms Accuracy within the temperature range - U m 0.06 % / °C Timing circuit Start-up delay tS Tripping tV fixed 500 ms (w20 %) fixed 150 ms (w20 %) at over-/ undervoltage fixed 500 ms (w20 %) fixed 500 ms fixed 500 ms Indication of operational states Relay status R: yellow LED V output relay energized Fault message F: red LED Only CM-PFS: V phase failure / V phase sequence error CM-PFS approx. 15 VA J J - - ERC CATALOG MEASURING AND MONITORING REL AYS 117 -- Three-phase monitoring relays Technical data Type Output circuits CM-PBE1) 13-14 CM-PBE CM-PVE1) CM-PVE CM-PFE 11-12/14 CM-PFE.2 Kind of output 1 n/o contact 1 c/o contact Operating principle closed-circuit principle2) Minimum switching voltage / Minimum switching current 24 V / 10 mA Maximum switching voltage / maximum switching voltage see data sheets Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category (Control Circuit B 300 pilot duty, general purpose 250 V, 4 A, cos phi 0.75 Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent 3600/360 VA power at B 300 Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 10 A fast-acting n/o contact 10 A fast-acting 6 A fast-acting Conventional thermal current Ith 4 A 1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured. 2) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. CM-PFS 1115-1216 / 1418, 2125-2226 / 2428 2 c/o contacts 118 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical data Type General data Duty cycle Dimensions Mounting Mounting position Minimum distance to other unites CM-PBE1) CM-PBE CM-PVE1) CM-PVE 100 % see dimensional drawings DIN rail (IEC/EN 60715) any horizontal not necesarry Degree of protection Electrical connection Connecting capacity Stripping length housing / terminals IP50 / IP20 fine-strand with wire end 2 x 0.75-1.5 mm² (2 x 18-16 AWG) ferrule fine-strand without wire end 2 x 1-1.5 mm² (2 x 18-16 AWG) ferrule rigid 2 x 0.75-1.5 mm² (2 x 18-16 AWG) 10 mm (0.39 in) Tightening torque Environmental data Ambient temperature range Climatic class Damp heat Damp heat, cyclic Vibration withstand Vibration, sinusoidal Shock Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Basic insulation Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive 0.6-0.8 Nm operation / storage -20..+60 °C / -40...+85 °C - IEC/EN 60068-2-30 40 °C, 93 % RH, 4 days IEC/EN 60068-2-30 IEC/EN 60068-2-6 10-57 Hz: 0.075 mm; 57-150 Hz: 1 g - between input, 400 V measuring and output circuits input circuit / output circuit output circuit 1 / output circuit 2 between input, 4 kV / 1.2 -50 s measuring and output circuits input circuit / output circuit output circuit 1 / output circuit 2 supply circuit / output circuit 3 III IEC/EN 60947-5-1, EN 50178 2014/35/EU 2014/30/EU 2011/65/EU CM-PFE CM-PFE.2 CM-PFS 10 mm if ambient 10 mm in temperature > 50 °C and case of rated operational currents > 2 A continuous measuring voltage > 440 V Same as CM-PSS.31 Same as CM-PSS.31 3K3 6 x 24 h cycle, 55 °C, 95 % RH class 2 class 2 - 600 V - 300 V 6 kV 4 kV 600 V AC IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178 ERC CATALOG MEASURING AND MONITORING REL AYS 119 -- Three-phase monitoring relays Technical data Type Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field CM-PBE1) CM-PBE CM-PVE1) CM-PVE IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 3 - 6 kV/ 8 kV IEC/EN 61000-4-3 level 3 - 10 V/m electrical fast transient / burst IEC/EN 61000-4-4 level 3 - 2 kV / 5 kHz surge IEC/EN 61000-4-5 level 4 - 2 kV L-L conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3 - 10 V voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 - harmonics and interharmonics IEC/EN 61000-4-13 - Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, Class B EN 55022 high-frequency conducted IEC/CISPR 22, Class B EN 55022 (1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured. CM-PFE CM-PFE.2 CM-PFS level 3 10 V/m (1 GHz) 3 V/m (2 GHz) 1 V/m (2.7 GHz) class 3 class 3 120 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical data Type CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41 Input circuit = Measuring circuit L1, L2, L3 Rated control supply voltage US = measuring voltage 3x380 V AC 3x400 V AC 3x160300 V AC 3x300500 V AC 3x200400 V AC 3x160300 V AC 3x300500 V AC Rated control supply voltage US tolerance Rated frequency -15...+10 % 50/60 Hz Frequency range 45-65 Hz Typical current / power consumption 25 mA / 25 mA / 25 mA / 10 25 mA / 19 mA / 25 mA / 25 mA 18 VA 18 VA VA 18 VA 10 VA 10 VA /18 VA (380 V AC) (400 V AC) (230 V AC) (400 V AC) (300 V AC) (230 V AC) (400 V AC) Measuring circuit L1, L2, L3 Monitoring functions J Phase failure J J J J J J Phase sequence can be switched off J J Automatic phase sequence - - - - - - - correction J Over- / undervoltage J J J J - - Phase unbalance - - - - - J J Neutral - - - - - - - Measuring range Overvoltage 3x418 V AC 3x440 V AC 3x220- 3x420- 3x300- - - 300 V AC 500 V AC 400 V AC Undervoltage 3x342 V AC 3x360 V AC 3x160- 3x300- 3x210- - - 230 V AC 380 V AC 300 V AC Phase - - - - - 2-25 % of average unbalance of phase voltages Thresholds Overvoltage fixed adjustable within measuring range - - Undervoltage fixed adjustable within measuring range - - Phase unbalance - - - - - adjust. within (switch-off value) measuring range Tolerance of the adjusted threshold value 6 % of full-scale value Hysteresis related to the threshold value Over- / undervoltage fixed 5 % - Phase unbalance - - - - - fixed 20 % Maximum measuring cycle time 100 ms Accuracy within the temperature range U 0.06 % / °C Measuring method true RMS Timing circuit Start-up delay tS Tripping delay tV fixed 200 ms ON- or OFF-delay 0; 0.1-30 s adjustable ON- delay 0; 0.1-30 s adjustable Repeat accuracy (constant parameters) - - - - < w 0.2 % - - Accuracy within the rated control supply voltage tolerance t 0.5 % Accuracy within the temperature range t 0.06 % / °C Indication of operational states 1 yellow LED, 2 red LEDs details see function details see operating mode and description / -diagrams function description / -diagrams details see function description / -diagrams Output circuits 15-16/18, 25-26/28 Kind of output Operating principle relay, 2 x 1 c/o contact closed-circuit principle1) Contact material AgNi alloy, Cd free Minimum switching power 24 V / 10 mA Maximum switching voltage see "Load limit curves" 1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value ERC CATALOG MEASURING AND MONITORING REL AYS 121 -- Three-phase monitoring relays Technical data Type CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41 Rated operational voltage Ue and AC-12 (resistive) 230 V 4 A rated operational current Ie AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category B 300 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking 3600/360 VA apparent power at B 300 Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting General data MTBF on request Duty cycle 100% Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units horizontal 10 mm (0.39 in) in case of continuous measuring voltages > 400 V > 400 V > 220 V > 400 V - > 220 V > 400 V Material of housing UL 94 V-0 Degree of protection housing / terminals IP50 / IP20 Electrical connection Wire size Screw connection technology Easy Connect Technology (Push-in) fine-strand with(out) wire 1 x 0.5-2.5 mm² (1 x 18-14 AWG) end ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (7.08 lb.in) - Environmental data Ambient temperature ranges operation / storage -25...+60 °C / -40...+85 °C Damp heat, cyclic (IEC 60068-2-30) 6 x 24 h cycle, 55 °C, 95 % RH Climatic class 3K3 Vibration (sinusoidal) class 2 Shock class 2 Isolation data Rated insulation voltage Ui input circuit / output circuit 600 V output circuit 1 / output circuit 2 300 V Rated impulse withstand voltage Uimp input circuit 6 kV; 1.2/50 s output circuit 4 kV; 1.2/50 s Basic insulation input circuit / output circuit 600 V Protective separation input circuit / output circuit Pollution degree 3 Overvoltage category III 122 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical data Type CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41 Standards / Directives Standards IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178 Low Voltage Directive 2014/35/EU EMC directive 2014/30/EU RoHS directive 2011/65/EU Electromagnetic compatibility Interference immunity to EN 61000-6-1 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz) surge IEC/EN 61000-4-5 Level 4 (2 kV L-L) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 (10 V) Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 class B high-frequency conducted IEC/CISPR 22, EN 55022 class B ERC CATALOG MEASURING AND MONITORING REL AYS 123 -- Three-phase monitoring relays Technical data Type CM-MPS.11 CM-MPS.21 CM-MPS.31 Input circuit = Measuring circuit L1, L2, L3, N L1, L2, L3 Rated control supply voltage US = measuring voltage 3x90-170 V AC 3x180-280 V AC 3x160-300 V AC Rated control supply voltage US tolerance -15...+10 % Rated frequency 50/60 Hz Frequency range 45-65 Hz Typical current / power consumption 25 mA / 10 VA (115 V AC) 25 mA / 18 VA (230 V AC) 25 mA / 10 VA (230 V AC) Measuring circuit Monitoring functions L1, L2, L3, N J Phase failure J L1, L2, L3 J Phase sequence can be switched off Automatic phase sequence - - - correction J Over- / undervoltage J J J Phase unbalance J J J Interrupted neutral J - Measuring range Overvoltage 3x120-170 V AC 3x240-280 V AC 3x220-300 V AC Undervoltage 3x90-130 V AC 3x180-220 V AC 3x160-230 V AC Phase unbalance 2-25 % of average of phase voltages Thresholds Overvoltage adjustable within measuring range Undervoltage adjustable within measuring range Phase unbalance (switch-off value) adjustable within measuring range Tolerance of the adjusted threshold value 6 % of full-scale value Hysteresis related to the threshold value Over- / undervoltage fixed 5 % Phase unbalance fixed 20 % Accuracy within the temperature range U 0.06 % / °C Measuring method True RMS Timing circuit Start-up delay tS fixed 200 ms Tripping delay tV ON- or OFF-delay 0; 0.1-30 s adjustable Accuracy within the rated control supply voltage tolerance t 0.5 % Accuracy within the temperature range t 0.06 % / °C Indication of operational states Details see function description / -diagrams Output circuits 15-16/18, 25-26/28 Kind of output relay, 1 x 2 c/o contacts Operating principle closed-circuit principle1) Contact material AgNi alloy, Cd free Minimum switching power 24 V / 10 mA Maximum switching voltage see load limit curves Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category B 300 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current 5 A at B 300 max. making/breaking 3600/360 VA apparent power at B 300 Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Max. fuse rating to achieve shortcircuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting 1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value CM-MPS.41 3x300-500 V AC 25 mA / 18 VA (400 V AC) J - J J 3x420-500 V AC 3x300-380 V AC 124 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical data Type General data CM-MPS.11 CM-MPS.21 CM-MPS.31 CM-MPS.41 MTBF Duty time on request 100 % Dimensions see dimension drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units Material of housing Degree of protection horizontal 10 mm (0.39 in) in case of continuous measuring voltages > 120 V > 240 V > 220 V UL 94 V-0 housing / terminals IP50 / IP20 > 400 V Electrical connection Wire size Stripping length Tightening torque Screw connection technology fine-strand with(out) wire end 1 x 0.5-2.5 mm² (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 8 mm (0.32 in) 0.6-0.8 Nm (7.08 lb.in) Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) - Environmental data Ambient temperature ranges Damp heat, cyclic operation / storage -25...+60 °C / -40...+85 °C 6 x 24 h cycle, 55 °C, 65 % RH Climatic class 3K3 Vibration Shock class 2 class 2 Isolation data Rated insulation input circuit / output circuit 600 V voltage Ui output circuit 1 / output circuit 2 300 V Rated impulse withstand input circuit 6 kV; 1.2/50 s voltage Uimp output circuit 4 kV; 1.2/50 s Test voltage between all isolated circuits (routine test) 2.5 kV, 50 Hz, 1 s Basic insulation input circuit / output circuit 600 V Protective separation (IEC/EN input circuit / yes - 61140, EN 50178) Pollution degree output circuit 3 Overvoltage category III Standards / Directives Standards Low Voltage Directive IEC/EN 60255-2, IEC/EN 60947-5-1, EN 50178 2014/35/EU EMC directive 2014/30/EU RoHS directive 2011/65/EU Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 3 (6 kV / 8 kV) radiated, radio-frequency, electromagnetic field electrical fast transient / burst IEC/EN 61000-4-3 level 3 (10 V/m) IEC/EN 61000-4-4 level 3 (2 kV / 2 kHz) surge IEC/EN 61000-4-5 level 4 (2 kV L-N) Level 4 (2 kV L-L) conducted disturbances, induced by radio-frequency fields harmonics and interharmonics IEC/EN 61000-4-6 level 3 (10 V) IEC/EN 61000-4-13 class 3 Interference emission EN 61000-6-3, EN 61000-6-4 high-frequency radiated high-frequency conducted IEC/CISPR 22, class B EN 55022 IEC/CISPR 22, class B EN 55022 ERC CATALOG MEASURING AND MONITORING REL AYS 125 -- Three-phase monitoring relays Technical data Type CM-MPS.23 CM-MPS.43 CM-MPN.52 Input circuit = Measuring circuit L1, L2, L3, N L1, L2, L3 Rated control supply voltage US = measuring voltage 3x180-280 V AC 3x300-500 V AC 3x350-580 V AC Rated control supply voltage US tolerance -15...+10 % Rated frequency 50/60/400 Hz 50/60 Hz Frequency range 45-440 Hz 45-65 Hz Typical current / power consumption 5 mA / 4 VA (230 V AC) 5 mA / 4 VA (400 V AC) 29 mA / 41 VA (480 V AC) Measuring circuit Monitoring functions L1, L2, L3, N L1, L2, L3 J Phase failure J J Phase sequence can be switched off Automatic phase sequence correction configurable J Over- / undervoltage J J J Phase unbalance J J J Interrupted neutral - - Measuring range Overvoltage 3x240-280 V AC 3x420-500 V AC 3x480-580 V AC Undervoltage 3x180-220 V AC 3x300-380 V AC 3x350-460 V AC Phase unbalance 2-25 % of average of phase voltages Thresholds Overvoltage adjustable within measuring range Undervoltage adjustable within measuring range Phase unbalance (switch-off value) adjustable within measuring range Tolerance of the adjusted thrshold value 6 % of full-scale value Hysteresis related to the threshold value Over- / undervoltage fixed 5 % Phase unbalance fixed 20 % Maximum measuring cycle time 100 ms Accuracy within the temperature range U 0.06 % / °C Measuring method True RMS Timing circuit Start-up delay tS and tS2 fixed 200 ms Start-up delay tS1 fixed 250 ms Tripping delay tV ON- or OFF-delay 0; 0.1-30 s adjustable Accuracy within the rated control supply voltage tolerance t 0.5 % Accuracy within the temperature range t 0.06 % / °C Indication of operational states Details see function description / -diagrams Output circuits 15-16/18, 25-26/28 Kind of output relay, 2 x 1 or 1 x 2 c/o contacts configurable Operating principle closed-circuit principle1) Contact material AgNi alloy, Cd free Minimum switching power 24 V / 10 mA Maximum switching voltage see load limit curves Rated operational voltage Ue and AC-12 (resistive) 230 V 4 A rated operational current Ie AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category B 300 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current 5 A at B 300 max. making/breaking apparent 3600/360 VA power at B 300 Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting 10 A fast-acting 1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value CM-MPN.62 3x450-720 V AC 29 mA / 52 VA (600 V AC) J J J 3x600-720 V AC 3x450-570 V AC CM-MPN.72 3x530-820 V AC 29 mA / 59 VA (690 V AC) J J J 3x690-820 V AC 3x530-660 V AC 126 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical data Type CM-MPS.23 CM-MPS.43 CM-MPN.52 CM-MPN.62 CM-MPN.72 General data MTBF on request Duty time 100 % Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units horizontal 10 mm (0.39 in) not necessary Material of housing UL 94 V-0 Degree of protection housing / terminals IP50 / IP20 Electrical connection Wire size Screw connection technology Easy Connect Technology (Push-in) fine-strand with(out) wire end 1 x 0.5-2.5 mm² (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 20-16 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (7.08 lb.in) - Environmental data Ambient temperature ranges operation / storage -25...+60 °C / -40...+85 °C Damp heat, cyclic (IEC 60068-2-30) 6 x 24 h cycles, 55 °C, 95 % RH Climatic category 3K3 Vibration (sinusoidal) (IEC/EN 60255-21-1) class 2 Shock (IEC/EN 60255-21-2) class 2 Isolation data Rated insulation v oltage Ui input circuit / 600 V output circuit 1000 V output circuit 1 / 2 300 V Rated impulse withstand voltage Uimp input circuit 6 kV; 1.2/50 s output circuit 4 kV; 1.2/50 s 8 kV; 1.2/50 s Basic insulation input circuit / output circuit 600 V 1000 V Protective separation (IEC/EN 61140, EN 50148) input circuit / output circuit Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 3 (6 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000-4-4 level 3 (2 kV / 2 kHz) surge IEC/EN 61000-4-5 level 4 (2 kV L-N) Level 4 (2 kV L-L) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3 (10 V) harmonics and interharmonics IEC/EN 61000-4-13 class 3 Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 class B high-frequency conducted IEC/CISPR 22, EN 55022 class B ERC CATALOG MEASURING AND MONITORING REL AYS 127 -- Three-phase monitoring relays Technical diagrams -- Connection diagrams CM-PBE, CM-PVE with neutral without neutral CM-PFE 1SVC 110 000 F0117 1SVC 110 000 F 0113 1SVC 110 000 F 0112 L1, L2, L3, (N) Control supply voltage = Measuring voltage 13-14 Output contact - closed-circuit principle CM-PVS.x1, CM-PSS.x1, CM-PAS.x1 L1 L2 L3 L1 L2 L3 15 25 2CDC 252 037 F0b08 2CDC 252 037 F0b08 16 18 26 28 26 25 28 16 15 18 L1, L2, L3 15-16/18 25-26/28 Control supply voltage = Measuring voltage Output contact - closed-circuit principle CM-MPS.11, CM-MPS.21, CM-MPS.23 L1 L2 L3 N L1 L2 L3 15 25 2CDC 252 036 F0b08 2CDC 252 036 F0b08 N 16 18 26 28 26 25 28 16 15 18 L1, L2, L3, (N) 15-16/18 25-26/28 Control supply voltage = Measuring voltage Output contact - closed-circuit principle CM-MPN.x2 L1 L2 L3 L1 L2 L3 15 25 2CDC 252 038 F0b08 2CDC 252 038 F0b08 16 18 26 28 16 15 18 26 25 28 L1, L2, L3 15-16/18 25-26/28 Control supply voltage = Measuring voltage Output contact - closed-circuit principle L1, L2, L3 Control supply voltage = Measuring voltage 11-12/14 Output contact - closed-circuit principle CM-PFS 1SVC 110 000 F 0118 L1, L2, L3 1115-1216 /1418 2125-2226/2428 Control supply voltage = Measuring voltage Output contact - closed-circuit principle CM-MPS.31, CM-MPS.41, CM-MPS.43 L1 L2 L3 L1 L2 L3 15 25 2CDC 252 037 F0b08 2CDC 252 037 F0b08 16 18 26 28 26 25 28 16 15 18 L1, L2, L3, (N) 15-16/18 25-26/28 Control supply voltage = Measuring voltage Output contact - closed-circuit principle 128 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Technical diagrams -- Rotary switch "Function" CM-PVS ON-delay with phase sequence monitoring OFF-delay with phase sequence monitoring ON-delay without phase sequence monitoring OFF-delay without phase sequence monitoring CM-PSS ON-delay with phase sequence monitoring OFF-delay with phase sequence monitoring ON-delay without phase sequence monitoring OFF-delay without phase sequence monitoring -- DIP switch functions CM-MPS.x3 and CM-MPN.x2 Position 4 3 2 1 ON OFF CM-MPS.x1 Position 2 1 ON OFF 22CCDDC 2252 04411 F00bb0088 2CDC 2252 04400FF00bb0088 1 Timing function ON ON-delayed OFF OFF-delayed 2 Phase sequence monitoring ON deactivated OFF activated 3 Operating principle of output ON 2x1 c/o contact OFF 1x2 c/o contact 4 Phase sequence correction ON activated OFF deactivated Output relay R1 is responsive to overvoltage, output relay R2 is responsive to undervoltage. In case of other faults, both output relays react synchronously. 1 Timing function ON ON-delayed OFF OFF-delayed 2 Phase sequence monitoring ON deactivated OFF activated ERC CATALOG MEASURING AND MONITORING REL AYS 129 -- Three-phase monitoring relays Function diagrams CM-PBE L1, L2, L3, N Measuring value with neutral 13-14 R: yellow LED L1, L2, L3, N ts L1, L2, N L1, L2, L3, N L2, L3, N L3 L1 tv <ts ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 150 ms L1, L2, L3, N ts L1, L2 L1, L2, L3, N L3 N <tv L1, L2, L3 Measuring value without neutral 13-14 R: yellow LED L1, L2, L3 ts L1, L2 L3 tv L1, L2, L3 <ts L1, L2 L3 ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 150 ms L1, L2, L3 ts L1, L2 L1, L2, L3 L3 <tv 2CDC 252 046 F0203 2CDC 252 045 F0203 Phase failure detection If all phases (and the neutral) are present, the output relay energizes after the start-up delay ts is complete. If a phase failure occurs, the tripping delay tv starts. When timing is complete, the output relay de-energizes. As soon as the voltage returns to the tolerance range, timing of ts starts. When timing is complete, the output relay re-energizes automatically. The yellow LED glows when the output relay is energized. CM-PVE L1, L2, L3, N Umax Umax - 5 % Measuring value with neutral Umin + 5 % Umin 13-14 R: yellow LED L1, L2, L3 Umax Umax - 5 % Measuring value without Umin + 5 % Umin neutral 13-14 R: yellow LED ts tv <ts ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms ts tv <ts ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms ts <tv tv ts ts <tv tv ts CM-PFE, CM-PFE.2 L1, L2, L3 Measuring value 11-14 11-12 R: yellow LED L1, L2, L3 ts L1, L3, L2 tv L1, L2, L3 ts ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms L1, L2 tv L3 L1, L2, L3 ts CM-PFS L1, L2, L3 Measuring value 11-14 11-12 21-24 21-22 R: yellow LED L1, L2, L3 ts L1, L3, L2 L1, L2, L3 L1, L2 L3 L1, L2, L3 L1 L2, L3 ts = start-up delay fixed 500 ms L1, L2, L3 ATTENTION If several CM-PFS units are placed side by side and the control supply voltage is higher than 415 V, spacing of at least 10mm has to be kept between the individual units. 2CDC 252 013 F0208 2CDC 252 061 F0208 2CDC 252 048 F0203 2CDC 252 047 F0203 Phase failure, under- / overvoltage detection If all phases (and the neutral) are present with correct voltage, the output relay energizes after the start-up delay ts is complete. If the voltage exceeds or falls below the fixed threshold value or if a phase failure occurs, the tripping delay tv starts. When timing is complete, the output relay deenergizes. As soon as the voltage returns to the tolerance range, timing of ts starts. When timing is complete, the output relay re-energizes automatically. The yellow LED glows when the output relay is energized. Phase failure detection, phase sequence monitoring If all phases are present with the correct phase sequence, the output relay energizes after the start-up delay ts is complete. If a phase failure or a phase sequence error occurs, the tripping delay tv starts. When timing is complete, the output relay de-energizes. The yellow LED glows when the output relay is energized. In case of motors which continue running with only two phases, the CM-PFE detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage. Phase failure detection, phase sequence monitoring If all phases are present with the correct phase sequence, the output relay energizes after the start-up delay ts is complete. If a phase failure or a phase sequence error occurs, the output relay de-energizes instantaneous. The yellow LED glows when the output relay is energized. In case of motors which continue running with only two phases, the CM-PFS detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage. 130 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Function diagrams CM-PSS.xx, CM-PVS.xx, CM.PAS.xx, CM-MPS.xx, CM-MPN.xx L1, L2, L3 Measuring value 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED L1, L2, L3 ts L1, L3, L2 L1, L2, L3 L1, L2 L3 L1, L2, L3 L1 L2, L3 ts = start-up delay fixed 200 ms L1, L2, L3 2CDC 252 094 F0207 Phase sequence monitoring and phase failure detection Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage, the output relays energize and the yellow LED R/T glows. Phase sequence monitoring If phase sequence monitoring is activated, the output relays de-energize as soon as a phase sequence error occurs. The fault is displayed by alternated flashing of the LEDs F1 and F2. The output relays re-energize automatically as soon as the phase sequence is correct again. CM-MPS.11, CM-MPS.21, CM-MPS.23 Phase failure detection The output relays de-energize instantaneous if a phase failure o ccurs. The fault is indicated by lighting of LED F1 and flashing of LED F2. The output relays re-energize automatically as soon as the voltage returns to the tolerance range. Displacement of the star point Interrupted neutral monitoring The interruption of the neutral in the main to be monitored is detected by means of phase unbalance evaluation. Determined by the system, in case of unloaded neutral (i.e. symmetrical load between all three phases) it may happen that an interruption of the neutral will not be detected. If the star point is displaced an asymmetrical load in the three-phase main, an interrupted neutral will be detected. ERC CATALOG MEASURING AND MONITORING REL AYS 131 -- Three-phase monitoring relays Function diagrams CM-MPS.x3, CM-MPN.x2 L1, L2, L3 Measuring value 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED L1, L2, L3 tS1 tS2 L1, L2 L3 L1, L2, L3 tS1 = start-up delay of R1 fixed 250 ms tS2 = start-up delay of R2 fixed 200 ms tS1 tS2 L1, L3, L2 L1 L2 L3 K1 15 18 16 25 K1 28 26 K1 N A1 A1 K2 K3 H1 A2 A2 Control circuit diagram (K1 = CM-MPS.23) L1 L2 L3 K1 15 18 16 25 K1 28 26 K1 N A1 A1 K2 K3 H1 A2 A2 Control circuit diagram (K1 = CM-MPS.43 or CM-MPN.xx) 2CDC253009F0014 2CDC253008F0014 2CDC 252 085 F0207 Automatic phase sequence correction This function can be selected only if phase sequence monitoring is activated k and operating mode 2x1 c/o (SPDT) contact j is selected. Applying control supply voltage begins the fixed start-up delay tS1. When tS1 is complete and all phases are present with correct voltage, output relay R1 energizes. Output relay R2 energizes when the fixed start-up delay tS2 is complete and all phases are present with the correct phase sequence. Output relay R2 remains de-energized if the phase sequence is incorrect. If the voltage to be monitored exceeds or falls below the set threshold values for phase unbalance, over- or undervoltage or if a phase failure occurs, output relay R1 de-energizes and the LEDs F1 and F2 indicate the fault. Output relay R2 is responsive only to a false phase sequence. In conjunction with a reversing contactor combination, this enables an automatic correction of the rotation direction. See circuit diagrams on the right. 2CDC 252 087 F0b07 L1 L2 L3 135 -F1 246 135 -K2 2 4 6 135 -K3 2 4 6 154 -F2 326 97 95 98 96 -M1 W1 V1 M U1 3 ~ Power circuit diagram 2CDC252087F0b07 132 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Function diagrams CM-PSS.xx (1), CM-PVS.xx (2), CM-MPS.xx (2), CM-MPN.xx (2) ON-delay A, 1x2 c/o contacts j 2CDC 252 090 F0207 L1, L2, L3 > U > U - 5 % Measuring value < U + 5 % < U 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED ts tv ts = start-up delay fixed 200 ms tv = adjustable tripping delay <tv tv OFF-delay B, 1x2 c/o contacts j L1, L2, L3 > U > U - 5 % Measuring value < U + 5 % < U 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED ts tv ts = start-up delay fixed 200 ms tv = adjustable tripping delay <tv <tv 2CDC 252 091 F0207 Over- and undervoltage monitoring j Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with the correct phase sequence, the output relays energize and the yellow LED R/T glows. Type of tripping delay = ON-delay If the voltage to be monitored exceeds or falls below the fixed (1) or set (2) threshold value, the output relays de-energize after the set tripping delay tV is complete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 % and the LED R/T glows. Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the fixed (1) or set (2) threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage returns to the t olerance range, taking into account a fixed hysteresis of 5 %, the output relays re-energize a utomatically after the set tripping delay tV is complete. The LED R/T flashes during timing and turns steady when timing is complete. ERC CATALOG MEASURING AND MONITORING REL AYS 133 -- Three-phase monitoring relays Function diagrams CM-MPS.x3, CM-MPN.x2 ON-delay A, 2x1 c/o contact i L1, L2, L3 > U > U - 5 % Measuring value < U + 5 % < U 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED ts tv ts = start-up delay fixed 200 ms tv = adjustable tripping delay <tv tv OFF-delay B, 2x1 c/o contact i L1, L2, L3 > U > U - 5 % Measuring value < U + 5 % < U 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED ts tv ts = start-up delay fixed 200 ms tv = adjustable tripping delay <tv <tv 2CDC 252 007 F0207 2CDC 252 006 F0207 Over- and undervoltage monitoring i Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with the correct phase sequence, the output relays energize. The yellow LED R/T glows as long as at least one output relay is energized. Type of tripping delay = ON-delay If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes after the set tripping delay tV is c omplete. The LED R/T flashes during timing. The corresponding output relay re-energizes automatically as soon as the voltage returns to the tolerance range, taking into a ccount a fixed hysteresis of 5 %. Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes instantaneously. As soon as the voltage returns to the tolerance range, taking into a ccount a fixed hysteresis of 5 %, the corresponding output relay re-energizes automatically after the set tripping delay tV is complete. The LED R/T flashes during timing. 134 ERC CATALOG MEASURING AND MONITORING REL AYS -- Three-phase monitoring relays Function diagrams CM-PAS.xx, CM-MPS.xx, CM-MPN.xx ON-delay A L1, L2, L3 Unbalance Unbalance - Hysteresis Measuring value Unbalance + Hysteresis Unbalance 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED L3 L1, L2, L3 L1, L2 ts tv ts = start-up delay fixed 200 ms tv = adjustable tripping delay <tv tv OFF-delay B L1, L2, L3 Unbalance Unbalance - Hysteresis Measuring value Unbalance + Hysteresis Unbalance 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED L3 L1, L2, L3 L1, L2 ts tv ts = start-up delay fixed 200 ms tv = adjustable tripping delay <tv <tv 2CDC 252 093 F0207 2CDC 252 092 F0207 Phase unbalance monitoring Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with the correct phase sequence, the output relays energize and the yellow LED R/T glows. Type of tripping delay = ON-delay If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize after the set tripping delay tV is c omplete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage r eturns to the tolerance range, taking into account a fixed hysteresis of 20% and the LED R/T glows. Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage r eturns to the tolerance range, taking into account a fixed hysteresis of 20%, the output relays re-energize automatically after the set tripping delay tV is complete. The LED R/T flashes during timing and turns steady when timing is complete. ERC CATALOG MEASURING AND MONITORING REL AYS 135 -- Three-phase monitoring relays Function diagrams CM-PSS.xx, CM-PSV.xx, CM-PAS.xx, CM-MPS.xx, CM-MPN.xx LED functions Function Control supply voltage applied, output relay energized Tripping delay tV active Phase failure Phase sequence Overvoltage Undervoltage Phase unbalance Interruption of the neutral Adjustment error R/T: F1: yellow LED red LED F2: red LED V- - W W - - VW W alternating V- - V VV VW WW Possible wrong adjustments of the front-facing operating controls Overlapping of the threshold values: · An overlapping of the threshold values is given if the threshold value for overvoltage is set to a smaller value than the threshold value for undervoltage. · DIP switch 3 = OFF · DIP switch 4 = ON: Automatic phase sequence correction is activated and selected operating mode is 1x2 c/o contacts · DIP switch 2 and 4 = ON: Phase sequence detection is deactivated and the automatic phase sequence correction is activated Type of tripping delay The type of tripping delay A / B can be adjusted via a rotary (CM-PxS.xx) or a DIP switch (CM-MPx.xx). Switch position ON-delay A: In case of a fault, the de-energizing of the output relays and the respective fault message are suppressed for the adjusted tripping delay tV. Switch position OFF-delay B: In case of a fault, the output relays de-energize instantaneously and a fault message is displayed and stored for the length of the adjusted tripping delay tV. Thereby, also momentary undervoltage conditions are recognized. 136 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 137 -- Grid feeding monitoring relays Table of contents 138 Benefits and advantages 143 Operating controls 144 Selection table 145 Ordering details 146 Technical data 147 Technical diagrams 138 ERC CATALOG MEASURING AND MONITORING REL AYS -- Grid feeding monitoring relays Benefits and advantages ABB's grid feeding monitoring relays detect unusual events in the public power grid and keeps it stable by automatically disconnecting and reconnecting the renewable power plant. The CM-UFD displays all relevant measuring data and events and can communicate them via a build-in communication interface. The cloud-based service AbilityTM EDCS enables customers to monitor the conditions in real-time, send the values into the cloud and access the diagnostics remotely. Optimum interface Reduce downtime by up to 70% Operate the device via LCD or remotely with the Modbus RTU. Users are informed immediately in case of an event in the public grid. Redundant microcontrollers ensure reliable measuring values and tripping. Global availability Cut installation time by up to 60% There's no need to learn every possible adjustment and its effects on your system ABB's trained staff supports your business and answers your technical questions promptly. Easy installation Commission & configure up to 60% faster Simple instructions, presets for local grid feeding standards, and ABB's intuitive menu structure make installation quicker. Commissioning and troubleshooting errors are prevented. ERC CATALOG MEASURING AND MONITORING REL AYS 139 -- Grid feeding monitoring relays Benefits and advantages ABB's CM-UFD range are multi-functional grid feeding monitoring relays, installed between the renewable energy system and the public grid. The innovative relays guarantee grid stability and prevent blackouts. If the public grid's voltage or frequency moves out of the permitted ranges, the device uses a decoupling unit (e.g. contactor or breaker Tmax XT) to separate the renewable energy system from the public grid. As soon as the grid is stable again, the system is automatically reconnected. The CM-UFD range provides different monitoring functions in accordance with several local grid feeding standards to detect over-/undervoltage and over-/underfrequency. Renewable energy system Modbus RTU Integration into ABB AbilityTM Electrical Distribution Control System Decoupling unit Modbus RTU Remote PLC for processing & visualization of measurement values Grid feeding monitoring relay CM-UFD.M*M with Modbus RTU Public grid Advantages · Highly accurate measurement and setting · Modbus RTU communication interface and ABB AbilityTM EDCS connectivity · Functional safety - single fault tolerances · Clear multiline, backlit LCD · Intuitive and user-friendly menu · Event storage · Pre-settings meet several local standards · Type-tested to a number of local grid feeding standards by TÜV Süd Functionality The device measures the ten-minute average value, voltage increases and decreases, as well as any changes in grid frequency. The rate of change of frequency (ROCOF) and vector shift monitoring to detect a loss of mains event can be easily configured. 140 ERC CATALOG MEASURING AND MONITORING REL AYS -- ABB ABILITYTM EDCS Monitor your renewable energy plant remotely with ABB´s smart ABB AbilityTM EDCS cloud platform. ERC CATALOG MEASURING AND MONITORING REL AYS 141 -- Grid feeding monitoring relays Benefits and advantages The cloud-based service AbilityTM EDCS enables customers to monitor the condition of CM-UFD.M*M in real-time and access the diagnostics remotely. This functionality is very important when operating in the field of critical power. Parametrize with ABB Ekip Connect and access data no matter where you are. -- Example architecture Ekip Com Hub Cloud Platform ABB Ability TM ABB Ability TM Ekip UP Modbus RS-485 CM-UFD The grid feeding monitoring relays can be connected to the cloud directly by using Ekip Com Hub module. Another option is to connect via Modbus RTU when there is some other device equipped with the Ekip Com Hub like the Emax 2 air-circuit breaker. In addition to the Ekip Connect 3 software, the following hardware is required: · Ekip UP (min. firmware 2.23) · Ekip Com Hub (min. firmware 1.18) · Ekip Com Modbus RTU (min. firmware 2.28) · Ekip Supply · Ekip T&P cable · CM-UFD.M*M (min. firmware 1.0.1) For further information regarding integration into ABB AbilityTM EDCS, please use the application note "2CDC112280M0101 CM-UFD.M*M integration into ABB AbilityTM EDCS". 142 ERC CATALOG MEASURING AND MONITORING REL AYS -- Grid feeding monitoring relays Benefits and advantages A reliable solution that takes country-specific requirements into account: the range is already pre-set to local requirements, making installation quick and simple. The devices can also be set manually with the display and used all over the world. Pre-set devices In accordance with a number of local standards, the CM-UFD relays can be used in all low voltage plants and in medium voltage plants. Type-tested To ensure reliability and compliance, the range is typetested to local standards by the third party authority TÜV Süd. -- Countries with a dedicated local standard (in red) Great Britain CM-UFD.M33* Austria CM-UFD.M31* France CM-UFD.M31* Italy CM-UFD.M22M Germany CM-UFD.M31* United Arabic Emirates CM-UFD.M34M -- Countries referring to an existing local standard or using a product with reference to another dedicated standard (in grey) South Africa CM-UFD.M31* CM-UFD.M22* Turkey Poland CM-UFD.M31* CM-UFD.M31* refers to DE standard Switzerland CM-UFD.M31* Jordan CM-UFD.M33* refers to GB standard Australia CM-UFD.M33* ERC CATALOG MEASURING AND MONITORING REL AYS 143 -- Grid feeding monitoring relays Operating controls Wide range power supply 24-240 V AC/DC 3 control inputs Measuring circuits L-L: 0-540 V AC L-N: 0-312 V AC Indication of operational states U/T: green LED V Control supply voltage applied W Timing F: red LED: Fault message Rx/Tx: yellow LED: Modbus frame reception and transmission Display 3 output relays Keypad ESC: escape / return to previous menu < : up / value increase < : down / value decrease OK: enter / confirm selection Modbus RTU interface 144 ERC CATALOG MEASURING AND MONITORING REL AYS -- Grid feeding monitoring relays Selection table CM-UFD.M34M 1SVR560731R3703 CM-UFD.M33M 1SVR560731R3702 CM-UFD.M33 1SVR560730R3402 CM-UFD.M31M 1SVR560731R3701 CM-UFD.M31 1SVR560730R3401 CM-UFD.M22M 1SVR560731R3700 Order number Type Rated control supply voltage Us 24-240 V AC/DC Standard CEI 0-21 VDE AR-N 4105, VDE AR-N 4110 ENA G98, G99 DRRG standard of DEWA Rated frequency DC or 50 Hz DC or 50/60 Hz Modbus RTU Suitable for monitoring Single-phase mains Three-phase mains Monitoring function Over-/undervoltage Over-/underfrequency ROCOF (rate of change of frequency) 10 minutes average value Vector shift Thresholds JJJJJJ J JJ JJ J JJJ JJJ J J JJ JJJJJJ JJJJJJ JJJJJJ JJJJJJ JJJJJJ JJJJJJ JJJJJ adj adj adj adj adj adj ERC CATALOG MEASURING AND MONITORING REL AYS 145 -- Grid feeding monitoring relays Ordering details CM-UFD.M*M 2CDC251003S0017 Description The grid feeding monitoring relays CM-UFD.M*M are designed to monitor the voltage and the frequency of the public low voltage or medium voltage grid. Whenever the measured values are not within the range of the adjusted threshold values, the CM-UFD.M*M causes tripping of the section switch (consisting of 1 or 2 switching devices according to the applicable standard). This tripping disconnects the power generation, such as photovoltaic systems, wind turbines, block-type thermal power stations from the grid. -- Ordering details Description Type See selection table CM-UFD.M22M CM-UFD.M31 CM-UFD.M31M CM-UFD.M33 CM-UFD.M33M CM-UFD.M34M Order code 1SVR560731R3700 1SVR560730R3401 1SVR560731R3701 1SVR560730R3402 1SVR560731R3702 1SVR560731R3703 Weight (1 pc) kg (lb) 0.312 (0.688) 0.304 (0.670) 0.312 (0.688) 0.304 (0.670) 0.312 (0.688) 0.312 (0.688) 146 ERC CATALOG MEASURING AND MONITORING REL AYS -- Grid feeding monitoring relays Technical data -- Data sheets For every product of the CM-UFD range, a technical data sheet is available. · Operating control and mode · Operating principles · Modbus RTU functionality where available · Electrical connection · Configuration and settings · Menu structure · Display and failure messages · Connection and wiring · Technical data · Technical diagrams · CAS system files -- Ordering data and data sheet numbers Description Type CM-UFD.M22M CM-UFD.M31 CM-UFD.M31M CM-UFD.M33 CM-UFD.M33M CM-UFD.M34M Order code 1SVR560731R3700 1SVR560730R3401 1SVR560731R3701 1SVR560730R3402 1SVR560731R3702 1SVR560731R3703 Data sheet number 2CDC112258D0201 2CDC112208D0201 2CDC112270D0201 2CDC112210D0201 2CDC112271D0201 2CDC112272D0201 For further information regarding integration into ABB AbilityTM EDCS, please use the application note "2CDC112280M0101 CM-UFD.M*M integration into ABB AbilityTM EDCS". ERC CATALOG MEASURING AND MONITORING REL AYS 147 -- Grid feeding monitoring relays Technical diagrams 2CDC252014F0017 2CDC252015F0017 -- Example of a single-phase application LN 1 230 V AC L1 N CP-E 24/X 11 L+ L- 24 V DC L+IN L-IN CP-B 24/X 12 L+OUTL-OUT 24 V DC 4 13 3 L1 N 2 -- Example of a three-phase application LN 1 230 V AC L1 N CP-E 24/X 11 L+ L- 24 V DC L+IN L-IN CP-B 24/X 12 4 L+ L- OUT OUT 24 V DC 13 3 5 L1 L2 L3 N 2 5 7 6 8 7 6 8 9 G 10 Legend 1. Control supply voltage for CM-UFD.M*M 2. Public grid 3. Protection fuse for the CM-UFD.M*M 4. Protection fuse for the measuring circuit of the CM-UFD.M*M (optional) 5. Short-circuit protection 6. Undervoltage release 7. Control input for feedback function 8. Switching device of the section switch 9. Switching device of the generator and/or inverter 10. Generator and/or inverter 11. Primary switch mode power supply unit CP-E (230 V AC / 24 V DC) for the buffer module CP-B 12. Ultra-capacitor based buffer module CP-B (24 V DC in/out) 13. Wire protection fuse for the output of the buffer module CP-B 7 6 8 7 6 8 9 G 10 148 ERC CATALOG MEASURING AND MONITORING REL AYS -- Grid feeding monitoring relays Technical diagrams -- Load limits curves V 300 V 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 1 -- AC load (resistive) 2 4 6 10 I A V 300 V 200 100 80 60 50 40 30 20 10 0.1 0.2 -- DC load (resistive) 0.5 1 2 4 6 10 I A 2CDC252193F0205 2CDC252194F0205 Switching cycles 2CDC252148F0206 1.0 0.9 0.8 F 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos -- Derating factor F at inductive AC load -- Dimensional drawings in mm and inches 67 2.64" 108 4.25" 2CDC252192F0205 -- Contact lifetime 250 V resistive load Switching current [A] 90 3.54" 2CDC252008F0013 ERC CATALOG MEASURING AND MONITORING REL AYS 149 150 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 151 -- Insulation monitoring relays for unearthed supply systems Table of contents 152 Benefits and advantages 156 Applications 157 Operating controls 160 Selection table 161 Ordering details 162 Technical data 169 Technical diagrams 152 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Benefits and advantages The insulation monitoring relays of the CM-IWx range guarantee a continuous insulation monitoring of an IT system. The devices recognize insulation faults as they develop and warn immediately if the value has fallen below the minimum set threshold. This ensures a reliable operation of the system and prevents operational interruption caused by a second, more severe, insulation fault which may lead to a short circuit tripping the main circuit breaker. 24 7 Continuous operation Keep the system online and reduce downtime with early pre-warnings which enable time for maintenance planning. Monitor voltage free networks for early fault detection. Due to variants with rail and ship approval, the devices have a wide range of applications. Safety and protection Safe and reliable detection of insulation faults according to the latest standards is what ABB's insulation monitoring relays deliver. The portfolio extends from standard to more challenging applications and can prevent fire due to fast and reliable earth fault detection. Built-in self-diagnosis and interrupted wire detection further ensure safety. Easy installation Read the status of the relay at a glance: clear visualization of the device status via LEDs. Easy to adjust with rotary wheels and variants with push-in terminals make a quick and easy installation and setting possible. ERC CATALOG MEASURING AND MONITORING REL AYS 153 -- Insulation monitoring relays Benefits and advantages Overview The CM-IWx product family offers a convincing solution for monitoring ungrounded AC, AC/DC and DC networks according to EN/IEC 61557-8. An IT network is supplied either by an isolating transformer or a voltage source, such as a battery or generator. In these systems, no active conductor is directly connected to earth potential. The high reliability of an IT system is guaranteed thanks to continuous insulation monitoring. The insulation monitoring device recognizes insulation faults (at least one conductor has a galvanic connection to earth potential) as they develop and immediately reports if the insulation resistance has fallen below a given threshold. Therefore, maintenance activities can be scheduled and executed while the plant keeps running. Main benefits · Increase plant availability and avoid costly unplanned stops of a plant / machine by quickly detecting faults first · Prevents fires due to detection of a creeping deterioration of the insulation resistance · The adjustment of the setting values is simple and done in a user-friendly way with rotary switches on the front of the device · Device status is displayed with LEDs that are easy to read and understand · Devices for standard and more challenging applications are available · Variants with rail and ship approvals are available 154 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Benefits and advantages -- CM-IWS.1 for unearthed pure AC systems The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 250 V AC and 300 V DC. It can be configured to the requirements of the applications and therefore has multi-functional uses. The device is available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals). · For monitoring the insulation resistance of unearthed IT systems up to Un = 250 V AC and 300 V DC · Test function · According to IEC/EN 61557-8 · Rated control supply voltage 24-240 V AC/DC · Prognostic measuring principle with superimposed square wave signal · One measuring range 1-100 k · 1 c/o (SPDT) contact, closed-circuit principle · Precise adjustment by front-face operating controls in 1 k steps · Interrupted wire detection · Fault storage / latching configurable by control input · Screw connection or Easy Connect Technology available · Housing material for highest fire protection classification UL 94 V-0 · Tool-free mounting on DIN rail as well as demounting · 22.5 mm width · 3 LEDs for status indication -- CM-IWS.2 for unearthed AC, DC or mixed AC/DC systems The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems with a voltage up to 400 V AC. The CM-IWS.2 can be configured to the requirements of the applications and therefore has multi-functional uses. The device is available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals). · For monitoring the insulation resistance of unearthed IT systems up to Un = 400 V AC · Test function · According to IEC/EN 61557-8 · Rated control supply voltage 24240 V AC/DC · Measuring principle with superimposed DC voltage · One measuring range 1-100 k · Fault storage / latching configurable by control input · Precise adjustment by front-face operating controls in 1 k steps · Screw connection or Easy Connect Technology available · Housing material for highest fire protection classification UL 94 V-0 · Tool-free mounting on DIN rail as well as demounting · 1 c/o (SPDT) contact, closed-circuit principle · 22.5 mm width · 3 LEDs for status indication ERC CATALOG MEASURING AND MONITORING REL AYS 155 -- Insulation monitoring relays Benefits and advantages -- CM-IWN.1 for unearthed AC, DC or mixed AC/DC systems The CM-IWN.1 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 400 V AC and 600 V DC. The measuring range can be extended up to 690 V AC and 1000 V DC by using the coupling unit CM-IVN. It can be configured to the requirements of the applications and therefore has multifunctional uses. The CM-IWN.1 is available with two different terminal versions. You can choose between the proven screw connection technology (double chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals). · For monitoring the insulation resistance of unearthed IT systems up to Un= 400 V AC and 600 V DC, expansion to 690 V AC and 1000 V DC with CM-IVN · Test function · According to IEC/EN 61557-8 · Rated control supply voltage 24-240 V AC/DC · Prognostic measuring principle with superimposed square wave signal · Two measuring ranges 1-100 k and 2-200 k · Precise adjustment of the measuring value in 1 or 2 kW steps · One (1 x 2 c/o) or two (2 x 1 c/o) threshold values Ran1/ R1 (warning) and Ran2/R2 (pre-warning) configurable(1) · Precise adjustment of the threshold values in 1 k steps (R1) and 2 k steps (R2) · Interrupted wire detection configurable · Non-volatile fault storage configurable · Open- or closed-circuit principle configurable · Screw connection or Easy Connect Technology available · Housing material for highest fire protection classification UL 94 V-0 · Tool-free mounting on DIN rail as well as demounting · 45 mm width · 3 LEDs for status indication -- CM-IWM.10 and CM-IWM.11 for unearthed AC, DC or mixed AC/DC systems with up to 1500 V measurement voltage The insulation monitors CM-IWM.10 and CM-IWM.11 provide the best and up-to-date insulation monitoring of modern IT systems in an optimum and state of-the-art way fulfilling the relevant standards. The devices can be used in the most flexible way for AC, DC and AC/DC systems even with large leakage capacity to earth (PE). The adjustment of the setting values is simple and done in a user-friendly way on two rotary switches on the front of the device. Via LEDs the measured value, device parameters and device status are indicated easy to read. · Insulation monitoring according to IEC/EN 61557-8 · Detection of symmetric and asymmetric insulation faults · 1 c/o contact each for pre-warning and warning · Measuring circuits can be disconnected via control termi- nals, e.g. for mains couplings · Pre-warning threshold setting range: 20 k ... 2 M · Warning threshold setting range: 1 k ... 250 k · Open- or closed-circuit principle configurable · Setting the maximum earth leakage capacitance to shorten the response time · Simple, clearly arranged adjustment of the device with screwdriver · LED chain to indicate the current insulation resistance · Display of active measuring circuits · Automatic and manual device self-test · Alarm storage selectable · External test and reset push button can be connected · 90 mm width 156 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Applications The CM-IWS.x and CM-IWN.x series provide L1 excellent insulation monitoring for general L2 purpose supply networks, such as: L3 N · Non-earthed AC, DC, AC/DC networks PE · UPS systems · Battery networks · Hybrid and battery-powered vehicles · Railway applications A1 11 S1 S2 S3 CMIWS.2 L w 14 12 A2 The power source in this case is the secondary side of an incoming transformer which isolates M the system for the application. 3~ Earth fault / insulation resistance monitoring of a 4-wire IT AC system with CM-IWS.2 CM-IWM.x can be additionally used in L+ special applications, such as: L- · Industrial networks with frequency PE inverters or direct current drives · Photovoltaic systems with high system leakage capacitance · Networks with system voltages up to L(+ ) L(-) *) G HM PE KE 1500 V DC or 1100 V AC without requiring a coupling unit · Installation on the AC or DC side of an 11-12/14: AL 21-22/24: VW CM-IWM.11 inverter · Networks which require measuring circuit deactivation in case two or more un- RG T A1+ A2 earthed networks are coupled DC Reset Test Power supply *) G-HM connected: Measuring circuit is off Example of a DC application with CM-IWM.11 Note: Only one insulation monitor must be connected and active in a network at the same time. ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Operating controls -- CM-IWM 157 Front-facing rotary switches to adjust threshold values Indication of operational state and measured ground fault resistance Test and reset button 158 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Operating controls -- CM-IWS Test and reset button Configuration and setting Front-face rotary switches for threshold value adjustment: · R.1 for R1 tens figures: 0, 10, 20, 30, 40, 50, 60, 70, 80, 90 k in ten k steps · R.2 for R1 units figures: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 k in one k steps Indication of operational states U: green LED - control supply voltage F: red LED - fault message R: yellow LED - relay status Marker label for devices without DIP switches ERC CATALOG MEASURING AND MONITORING REL AYS 159 -- Insulation monitoring relays Operating controls -- CM-IWN Front-face rotary switches to adjust the threshold value: · R1.1 for R1 tens figure: 0, 10, 20, 30, 40, 50, 60, 70, 80, 90 k in ten k steps · R1.2 for R1 units figure: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 k in one k steps · R2.1 for R2 tens figure: 0, 20, 40, 60, 80, 100, 120, 140, 160, 180 k in twenty k steps · R2.2 for R2 units figure: 2, 4, 6, 8, 10, 12, 14, 16, 18, 20 k in two k steps Test and reset button Indication of operational states U: green LED control supply voltage F1: red LED fault message F2: yellow LED relay status DIP switches (see DIP switch functions) 160 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Selection table CM-IWM.11 1SVR470670R1100 CM-IWM.10 1SVR470670R1000 CM-IWN.1P 1SVR760660R0200 CM-IWN.1S 1SVR750660R0200 CM-IWS.1P 1SVR740660R0100 CM-IWS.1S 1SVR730660R0100 CM-IWS.2P 1SVR740670R0200 CM-IWS.2S 1SVR730670R0200 Order number Type Rated control supply voltage Us 24 - 240 V AC/DC 24 V DC Measuring voltages 250 V AC (L-PE) 400 V AC (L-PE) 690 V AC (L-PE) 1000 V AC (L-PE) 300 V DC (L-PE) 600 V DC (L-PE) 690 V DC (L-PE) 1000 V DC (L-PE) Measuring range 1 - 100 k 2 - 200 k 2 - 250 k System leakage capacitance, max. 10 F 20 F 1000 F 3000 F Output 1 c/o 1 x 2 c/o or 2 x 1 c/o 2 c/o Operating principle Open-circuit principle Open- or closed-circuit principle adjustable Test Front-face button or control input Reset Front-face button or control input Fault storage / latching configurable Non volatile storage configurable Interrupted wire detection Threshold values configurable Control input (measuring input deactivation) Connection type Push-in terminals Double-chamber cage connection terminals Screw terminals JJJJJJ JJ JJ JJ JJ J J J (1) (1) (2) J (3) JJ JJ J (2) J J (1) (1) J (3) JJJJJJ JJ JJ JJJJ JJ J J JJJJ JJ JJ JJJJ JJ JJ JJJJJJJJ JJJJJJJJ JJJJJJ JJJJJJ JJJJ 11112222 J JJJ JJJ JJ 1) With coupling unit CM-IVN screw version CM-IVN.S: 1SVR750669R9400 push-in version CM-IVN.P: 1SVR760669R9400 2) Allowed voltage range of the supervised network: 0-760 V AC / 0-1000 V 3) Allowed voltage range of the supervised network: 0-1100 V AC / 0-1500 V DC ERC CATALOG MEASURING AND MONITORING REL AYS 161 -- Insulation monitoring relays Ordering details CM-IWS.1 CM-IWS.2 CM-IWN.1 CM-IVN 2CDC 251 017 V0012 2CDC 251 009 V0012 2CDC 252 027 V0012 2CDC 251 020 V0012 Description The CM-IWx serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or IT DC systems. The devices are able to monitor control circuits (single-phase) and main circuits (3-phase). The CM-IWM.x provides the best and up-to-date insulation monitoring of modern IT supply systems in an optimum and state of-the-art way according to IEC 61558-8 including annex C. The device can be used in the most flexible way for AC, DC and AC/DC systems, even with a large leakage capacity to earth (PE) and under adverse conditions. -- Ordering details Type Rated control supply voltage Nominal voltage Un of the distribution system to be monitored System leakage capacitance, max. Adjustment range of the specified response value Ran (threshold) Type Order code CM-IWS.x 24-240 0-250 V AC / 10 F V AC/DC 0-300 V DC 1-100 k CM-IWS.1S 1SVR730660R0100 CM-IWS.1P 1SVR740660R0100 0-400 V AC CM-IWS.2S 1SVR730670R0200 CM-IWS.2P 1SVR740670R0200 CM-IWN.x 0-400 V AC / 20 F 0-600 V DC 1-100 k 2-200 k CM-IWN.1S 1SVR750660R0200 CM-IWN.1P 1SVR760660R0200 CM-IWM.x 24 V DC 0-690 V AC/DC 1) 0-1000 V AC/DC 2) 1000 F 1-250 k 20 k-2 M 3000 F CM-IWM.10 1SVR470670R1000 CM-IWM.11 1SVR470670R1100 1) Allowed voltage range of the supervised network: 0-760 V AC / 0-1000 V DC 2) Allowed voltage range of the supervised network: 0-1100 V AC / 0-1500 V DC Weight (1 pc) kg (lb) 0.148 (0.326) 0.137 (0.302) 0.141 (0.311) 0.130 (0.287) 0.241 (0.531) 0.217 (0.478) 0.500 (1.1) Coupling unit Rated control supply voltage = measuring voltage Nominal voltage Un of the distribution system to be monitored Type Order code Passive device, no control supply voltage needed 0-690 V AC / 0-1000 V DC CM-IVN.S 1SVR750669R9400 CM-IVN.P 1SVR760669R9400 S: screw connection P: push-in connection Weight (1 pc) kg (lb) 0.179 (0.395) 0.165 (0.364) 162 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical data - CM-IWx Data at Ta = 25 °C and rated values, unless otherwise indicated CM-IWS.2 CM-IWS.1 CM-IWN.1 Input circuit - Supply circuit A1 - A2 Rated control supply voltage Us 24-240 V AC/DC Rated control supply voltage tolerance -15...+10 % Typical current / power consumption 24 V DC 30 mA / 0.7 VA 35 mA / 0.9 VA 55 mA / 1.3 VA 115 V AC 12 mA / 1.4 VA 17 mA / 2.0 VA 20 mA / 2.3 VA 230 V AC 12 mA / 2.8 VA 14 mA / 3.2 VA 15 mA / 3.5 VA Rated frequency fs DC or 15-400 Hz Frequency range AC 13.5-440 Hz Power failure buffering time min. 20 ms Start-up time ts, fixed min. 10 s max. 15 s min. 15 s Input circuit - Measuring circuit L, w L+, L-, w, KE L+, L-, w, KE Monitoring function insulation resistance monitoring of IT systems Measuring principle superimposed DC voltage prognostic measuring principle with superimposed square wave signal Nominal voltage Un of the distribution system to be monitored 0-400 V AC 0-250 V AC / 0-300 V DC 0-400 V AC / 0-600 V DC Voltage range of the distribution system to be monitored 0-460 V AC (tolerance +15 %) 0-287.5 V AC / 0-345 V DC (tolerance +15 %) 0-460 V AC / 0-690 V DC (tolerance +15 %) Rated frequency fN of the distribution system to be monitored 50-60 Hz DC or 15-400 Hz DC or 15-400 Hz System leakage capacitance Ce max. 10 F 20 F Tolerance of the rated frequency fN Extraneous DC voltage Ufg (when connected to an AC system) Number of possible response / threshold values Adjustment range of the specified response value Ran (threshold) 45-65 Hz max. none 1 min.-max. 1-100 h min.-max. R1 min.-max. R2 Adjustment resolution Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+45 °C Un = 0-115 % Us = 85-110 %, fN, fs, Ce = 1F 1 kh R1 1 kh R2 at 1-10 kW RF 15 %, max. ±0.5 kh (yellow marked scale) at 10-100 kW ±6 % RF at 1-15 kW RF at 15-200 kW RF Hysteresis related to the threshold value 25 %; min. 2 kh Internal impedance Zi at 50 Hz 135 kh Internal DC resistance Ri 185 kh Measuring voltage Um 15 V Tolerance of measuring voltage Um +10 % Measuring current Im max. 0.1 mA Response time tan pure AC system 0.5 x Ran and Ce = 1 F max. 10 s DC system or AC system with connected rectifiers Repeat accuracy (constant parameters) < 0.1 % of full scale Accuracy of Ra (measured value) within the rated control supply < 0.05 % of full scale voltage tolerance Accuracy of Ra (measured value) within the operation temperature range at 1-10 kh RF 5 W / K at 10-100 kh RF 0.05 % / K at 10-200 kh RF Transient overvoltage protection (w - terminal) Z-diode 13.5-440 Hz 290 V DC 100 kh 115 kh 22 V 0.3 mA max. 15 s avalanche diode 13.5-440 Hz 460 V DC 2 1-100 kh 2-200 kh (activated / deactivated by DIP-switch) 1 kh 2 kh 15 %, max. ± 1 kh, with CM-IVN ± 1.5 kh ± 1 kh, with CM-IVN ± 1.5 kh ±8 % 155 kh 185 kh 24 V 0.15 mA 0.05 % / K ERC CATALOG MEASURING AND MONITORING REL AYS 163 -- Insulation monitoring relays Technical data - CM-IWx CM-IWS.2 CM-IWS.1 CM-IWN.1 Input circuit - Control circuits S1 - S2 - S3 Control inputs - volt free S1-S3 remote test S2-S3 remote reset Maximum switching current in the control circuit 1 mA Maximum cable length to the control inputs 50 m - 100 pF/m [164 ft - 30.5 pF/ft] Minimum control pulse length 150 ms No-load voltage at the control input 24 V ± 5 % 24 V DC Indication of operational states Control supply voltage LED U (green) Fault message LED F (red) Relay status LED R (yellow) Output circuits Kind of output relay, 1 c/o (SPDT) contact 2 x 1 or 1 x 2 c/o (SPDT) contacts configurable Operating principle closed-circuit principle1) open- or closed circuit principle configurable1) Contact material AgNi alloy, Cd free Min. switching voltage / Min. switching current 24 V / 10 mA Max. switching voltage / Max. switching current see data sheet Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC rating (UL 508) Utilization category B 300, pilot duty general purpose 250 V, 4 A, cos 0.75 (Control Circuit Rating Code) max. rated operational voltage 250 V AC max. continuous thermal current 4 A at B 300 max. making/breaking apparent 3600/360 VA power at B 300 Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting Conventional thermal current Ith 4 A General data Duty cycle 100 % Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical not necessary horizontal 10 mm (0.39 in) at Un > 240 V not necessary 10 mm (0.39 in) at Un > 400 V Material of housing UL 94 V-0 Degree of protection housing / terminal IP50 / IP20 Electrical connection Screw connection technology Easy Connect Technology (Push-in) Wire size fine-strand with(out) 1 x 0.5-2.5 mm² (1 x 18-14 AWG) wire end ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) (1) Closed-circuit principle: Output relay(s) de-energize(s) if a fault is occurring Open-circuit principle: Output relay(s) energize(s) if a fault is occurring 164 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical data - CM-IWx CM-IWS.2 CM-IWS.1 CM-IWN.1 Environmental data Ambient temperature ranges operation / storage / transport -25...+60 °C/-40...+85 °C/-40...+85 °C Climatic class IEC/EN 60721-3-3 3K5 (no condensation, no ice formation) Damp heat, cyclic IEC/EN 60068-2-30 6 x 24 h cycle, 55 °C, 95 % RH Vibration, sinusoidal 25 Hz: 2.5 g Isolation data Rated impulse withstand voltage Uimp supply / measuring circuit 6 kV supply / output circuit 6 kV measuring / output circuit 6 kV output 1 / output circuit 2 4 kV Rated insulation voltage Ui supply / measuring circuit 400 V supply / output circuit 300 V 300 V 600 V supply / measuring circuit 400 V 300 V 600 V output 1 / output circuit 2 - - 300 V Basis insulation supply / measuring circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC supply / output circuit 250 V AC / 300 V DC measuring / output circuit 400 V AC / 300 V DC 250 V AC / 300 V DC 400 V AC / 600 V DC output 1 / output 2 250 V AC / 300 V DC Protective separation (IEC/EN 61140) supply / output circuit 250 V AC / 250 V DC supply / measuring circuit 250 V AC / 250 V DC measuring / output circuit 250 V AC / 250 V DC Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60947-5-1, IEC/EN 61557-1, IEC/EN 61557-8 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2, IEC/EN 61326-2-4 electrostatic discharge IEC/EN 61000-4-2 level 3, 6 kV / 8 kV radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) electrical fast transient/burst IEC/EN 61000-4-4 level 3, 2 kV / 5 kHz surge IEC/EN 61000-4-5 level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3, 10 V voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 class 3 harmonics and interharmonics IEC/EN 61000-4-13 class 3 Interference emissions IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 class B high-frequency conducted IEC/CISPR 22, EN 55022 class B ERC CATALOG MEASURING AND MONITORING REL AYS 165 -- Insulation monitoring relays Technical data - CM-IVN CM-IVN Input circuit - Measuring circuit VL+, VL-, Vw Function expansion of the nominal voltage range of the insulation monitoring relay CM-IWN to 690 V AC or 1000 V DC, max. length of connection cable 40 cm Measuring principle see CM-IWN Nominal voltage Un of the distribution system to be monitored 0-690 V AC / 0-1000 V DC Voltage range of the distribution system to be monitored 0-793.5 V AC / 0-1150 V DC (tolerance +15 %) Rated frequency fN of the distribution system to be monitored Tolerance of the rated frequency fN System leakage capacitance Ce Extraneous DC voltage Ufg (when connected to an AC system) DC or 15-400 Hz 13.5-440 Hz max. identical to that of the insulation monitoring relay used max. 793.5 V DC Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+ 45 °C, Un = 0-115 %, Us = 85-110 %, fN, fs, Ce = 1 F Internal impedance Zi Internal DC resistance Ri Measuring voltage Um Tolerance of measuring voltage Um Measuring current Im at 1-15 k RF ±1.5 k at 15-200 k RF ±8 % at 50 Hz 195 k 200 k 24 V +10 % 0.15 mA General data MTBF on request Duty cycle 100 % Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical not necessary Degree of protection horizontal 10 mm (0.39 in) at Un > 600 V IP50 / IP20 Electrical connection Wire size fine-strand with(out) wire 2 x 0.75-2.5 mm² (2 x 18-14 AWG) end ferrule rigid 2 x 0.5-4 mm² (2 x 20-12 AWG) Stripping length 7 mm (0.28 In) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.In) Max. length of connection cable to CM-IWN 40 cm Environmental data Ambient temperature ranges operation / storage / transport -25...+60 °C / -40...+85 °C / -40...+85 °C Climatic category IEC/EN 60721-3-3 3K5 (no condensation, no ice formation) Damp heat, cyclic IEC/EN 60068-2-30 6 x 24 h cycle, 55 °C, 95 % RH Vibration, sinusoidal IEC/EN 60255-21-1 Class 2 Shock, half-sine IEC/EN 60255-21-2 Class 2 Isolation data Rated impulse withstand voltage Uimp Rated insulation voltage Ui Pollution degree input circuit / PE 8 kV input circuit / PE 1000 V 3 Overvoltage category III Standards / Directives Standards IEC/EN 60947-5-1, IEC/EN 61557-1, IEC/EN 61557-8 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU 166 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical data - CM-IVN Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted CM-IVN IEC/EN 61000-6-2, IEC/EN 61326-2-4 IEC/EN 61000-4-2 level 3, 6 kV / 8 kV IEC/EN 61000-4-3 level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) IEC/EN 61000-4-4 level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth IEC/EN 61000-4-6 level 3, 10 V IEC/EN 61000-4-11 level 3 IEC/EN 61000-4-13 level 3 IEC/EN 61000-6-3 IEC/CISPR 22, EN 50022 class B IEC/CISPR 22, EN 50022 class B ERC CATALOG MEASURING AND MONITORING REL AYS 167 -- Insulation monitoring relays Technical data - CM-IWM Input circuit Rated control supply voltage US Voltage range Typical power consumption Measuring circuit Nominal voltage UN Allowed voltage range of the supervised network Frequency range Max. system leakage capacitance Ce Internal resistance (AC/DC) Measuring voltage Max. measured current (RE = 0) Response values RE each adjustable via rotary switches Response inaccuracy Response value hysteresis ON delay Control input Current flow No-load voltage to ground Permissible wire length Min. activation time Output Contacts Thermal current Ith Switching capacity to AC-15 Electrical life Short circuit strength max. fuse rating Mechanical life CM-IWM.10 CM-IWM.11 24 V DC 20-30 V DC max. 5 W L(+) / L(-) to PE / KE 0-690 V AC/DC 0-760 V AC / 0-1000 V DC DC or 16-1000 Hz 1000 F > 280 k approx. ± 95 V < 0.35 mA 0-1000 V AC/DC 0-1100 V AC / 0-1500 V DC DC or 16-1000 Hz 3000 F pre-warning ("VW") warning ("AL") 20 k 1 k 30 k 3 k 50 k 10 k 70 k 20 k 100 k 30 k 150 k 50 k 250 k 70 k 500 k 100 k 1000 k 150 k 2000 k 250 k IEC/EN 61557-8 ± 15 % + 1.5 k at range 10 k ... 700 k approx. 25 % out of range: approx. 40 % + 0.5 k at CE = 1 F < 10 s RE of to 0.5 * response value between T, R and G approx. 3 mA approx. 12 V < 50 m 0.5 s between HM, T, R and G 2 x 1 c/o contacts for VW and AL 4 A n/o contact 3 A / AC 230 V acc. to IEC/EN 60947-5-1 n/c contact 1 A / AC 230 V acc. to IEC/EN 60947-5-1 at 8 A, AC 250 V 1 x 104 switching cycles 4 A gL acc. to IEC/EN 60947-5-1 10 x 106 switching cycles 168 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical data - CM-IWM CM-IWM.10 CM-IWM.11 General Data Operating mode continuous operation Temperature range operation - 25 ... + 60 °C - 25 ... + 60 °C (device mounted away from heat generation components) -25 ... +45 °C (device mounted without distance to other devices) storage - 40 ... + 70 °C Relative air humidity 93 % at 40 °C Atmospheric pressure 860-1600 mbar (86-106 kPa) Altitude IEC/EN 60664-1 < 4000 m Clearance and creepage distances Rated impulse voltage / pollution degree IEC/EN 60664-1 Measuring ciruit L(+) / L(-) to auxiliary voltage DC and 8 kV / 2 relay contacts VW, AL auxiliary voltage DC to 8 kV / 2 relay contacts VW, AL relay contacts VW to relay contact AL 4 kV / 2 Insulation test voltage, routine test AC 5 kV; 1 s AC 2.5 kV; 1 s Technical data EMC Electrostatic discharge (ESD) IEC/EN 61000-4-2 8 kV (air) HF irradiation IEC/EN 61000-4-3 80 MHz-2.7 GHz: 10 V/m Fast transients IEC/EN 61000-4-4 4 kV Surge voltages IEC/EN 61000-4-5 between A1 - A2: 1 kV L(+) - L(-): 2 kV A1, A2 - PE: 4 kV L(+), L(-) - PE: 4 kV control line: 0.5 kV control line and earth: 1 kV HF-wire guided IEC/EN 61000-4-6 10 V Interference suppression EN 55011 limit value class A when connected to a low voltage public system (Class B, EN 55011) radio interference can be generated. To avoid this, appropriate measures have to be taken Degree of protection Housing IEC/EN 60529 IP 40 Terminals IEC/EN 60529 IP 20 Housing thermpolastic with V0 behaviour according to UL subject 94 Vibration resistance IEC/EN 60068-2-6 10-55 Hz: 0.35 mm 2-13.2 Hz: ± 1 mm 13.2-100 Hz: ± 7 g Shock resistance IEC/EN 60068-2-27 10 g / 11 ms, 3 pulses Climate resistance IEC/EN 60068-1 25 / 060 / 04 Terminal designation EN 50005 Connecting capacity 1 x 4 mm2 solid 1 x 2.5 mm2 stranded ferruled (isolated) 2 x 1.5 mm2 stranded ferruled (isolated) DIN 46228-1/-2/-3-4 2 x 2.5 mm2 stranded ferruled (isolated) DIN 46228-1/-2/-3 Stripping length 8 mm Tightening torque 0.8 Nm Wire fixing plus-minus terminal scews M3.5 terminal with wire protection Mounting IEC/EN 60715 DIN rail Dimensions width x height x depth 90 x 90 x 121 mm ERC CATALOG MEASURING AND MONITORING REL AYS 169 -- Insulation monitoring relays Technical diagrams -- LEDs, status information and fault messages CM-IWN.x CM-IWS.x Operational state LED U LED F (green) (red) Start-up W OFF No fault V OFF Prewarning VW Insulation fault (below threshold value) V V KE/w wire interruption VU L+/L- wire interruption during system start-up / test function W / X T System leakage capacitance too high / V T invalid measurement result Internal system fault (1) X Setting fault (2) WW Test function X OFF No fault after fault storage (3) V (4) LED R (yellow) OFF (1) W (1) (1) (1) (1) (1) W (1) X Operational state LED U (green) Start-up W No fault V Insulation fault (below threshold value) V Invalid measuring result V KE/w wire interruption (only CM-IWS. (1) V CM-IWS.1: System leakage capacitance too high / invalid measurement result X CM-IWS.2: Invalid measurement result V Internal system fault OFF Test function X No fault after fault storage (3) V LED F (red) OFF OFF V T U X T X OFF (4) LED R (yellow) OFF V OFF OFF OFF OFF OFF OFF OFF X (1) Depending on the configuration. (2) Possible faulty setting: The threshold value for final switch-off is set at a higher value than the threshold value for prewarning (3) The device has triggered after an insulation fault. The fault has been stored and the insulation resistance has returned to a higher value than the threshold value plus hysteresis. (4) Depending on the fault CM-IWM.x LED status PWR: green LED ERR: red LED Active: green LED LED chain: yellow LED VW +: yellow LED VW -: yellow LED VW + and VW -: yellow LED AL +: red LED AL -: red LED AL + and AL -: red LED LED V V S U Z Y V V V V Status Control supply voltage applied Internal device error Connection error L+/LConnection error PE/KE Measuring phase with positive polarity Measuring phase with negative polarity 8 LEDs indicate the current insulating resistance ( 10 k ... 2 M) RE lower than prewarning value to + potential RE lower than prewarning value to - potential AC fault / symmetric fault V V V RE lower than warning value to + potential RE lower than warning value to - potential AC fault / symmetric fault 170 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical diagrams -- Connection diagrams CM-IWS.2 A1 11 S1 S2 S3 Lw 11 R < w A1 A2 L 14 12 12 14 w A2 2CDC 252 102 F0009 A1-A2 S1-S3 S2-S3 L w 11-12/14 Control supply voltage Remote test Remote reset Measuring circuit/input, system connection Measuring circuit/input, earth connections Output relay, closed-circuit principle CM-IWN.1 A1 11 21 S1 S2 S3 L+ L- KE w 11 21 2CDC 252 104 F0009 R < w A1 A2 12 14 22 24 12 14 L+ VS V1+ V1- 22 24 L- KE w A2 A1-A2 S1-S3 S2-S3 L+, L w, KE VS, V1+, V1 11-12/14 21-22/24 Control supply voltage Remote test Remote reset Measuring circuit/input, system connection Measuring circuit/input, earth connections Connections for the coupling unit (if used) Output relay 1, open- or closed-circuit principle Output relay 2, open- or closed-circuit principle CM-IWS.1 A1 11 KE S1 S2 S3 L+ L- KE w 11 R < w A1 A2 12 14 L+ L- w 14 12 A2 2CDC 252 103 F0009 A1-A2 Control supply voltage S1-S3 Remote test S2-S3 Remote reset L+, L Measuring circuit/input, system connection w, KE Measuring circuit/input, earth connections 1-12/14 Output relay, closed-circuit principle CM-IVN VL+ VL- VL- VL+ 2CDC 252 010 F0013 L- V1- L+ V1+ L+ V1+ L- V1- VS VE Vw VE Connection to CM-IWN.x - w VS Connection to CM-IWN.x - VS L+ Connection to CM-IWN.x - L+ V1+ Connection to CM-IWN.x - V1+ L- Connection to CM-IWN.x - L- V1- Connection to CM-IWN.x - V1- VL+ Measuring circuit / Measuring input, VL- Connection to the system Vw Measuring circuit / Measuring input, Connection to earth ERC CATALOG MEASURING AND MONITORING REL AYS 171 -- Insulation monitoring relays Technical diagrams -- Connection diagrams CM-IWM.10 L (+) L (-) 11 12 14 21 22 24 Us GT KE PE G R L+ LPE KE 12 14 22 24 11 21 A1 + A2 CM-IWM.11 L (+) L (-) 11 12 14 21 22 24 Us G HM G T KE PE G R L+ LPE KE 12 14 22 24 11 21 A1 + A2 2CDC252005F0016 2CDC252012F0016 Terminal designation A1+, A2 L(+), L(-) KE, PE G, R G, T 11-12/14 21-22/24 Signal designation Control supply voltage Connection for measuring ciruit Connection for protective conductor Control input (manual/auto reset) · G/R not jumpered: manual reset · G/R jumpered: auto reset Control input (External test input) connection for an external device test pushbutton Output relay 1 (warning) Output relay 2 (prewarning) Terminal designation A1+, A2 L(+), L(-) KE, PE G, R G, T G, HM 11-12/14 21-22/24 Signal designation Control supply voltage Connection for measuring ciruit Connection for protective conductor Control input (manual/auto reset) · G/R not jumpered: manual reset · G/R jumpered: auto reset Control input (External test input) connection for an external device test pushbutton Control input (measuring circuit deactivation) · G/HM not jumpered: measuring circuit activated · G/HM jumpered: measuring circuit deactivated Output relay 1 (warning) Output relay 2 (prewarning) 172 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical diagrams -- DIP switches CM-IWN.1 Position 4 3 2 1 ON i u f g OFF j v e h 2CDC 252 050 F0b09 DIP switch 1 Operating principle of the output relays ON OFF (default) Closed-circuit principle g Open-circuit principle h If closed-circuit principle is selected, If open-circuit principle is selected, the output relays de-energize in case the output relays energize in case a a fault is occurring. In non-fault fault is occurring. In non-fault state state the relays are energized. the relays are de-energized. DIP switch 2 Non-volatile fault storage Fault storage activated (latching) f If the fault storage function is activated, the output relays remain in tripped position until a reset is done either by the front-face button or by the remote reset connection S2-S3. This function is non-volatile. Fault storage de-activated (non latching) e If the fault storage function is deactivated, the output relays switch back to their original position as soon as the insulation fault no longer exists. DIP switch 3 Interrupted wire detection Interrupted wire detection activated u With this configuration, the CMIWN.1 monitoring relays the wires connected to w and KE for interruptions. Interrupted wire detection deactivated v With this configuration the interrupted wire detection is de-activated. DIP switch 4 2 x 1 c/o, 1 x 2 c/o 2 x 1 c/o (SPDT) contact i If operating principle 2 x 1 c/o contact is selected, the output relay R1 (11-12/14) reacts to threshold value R1 (final switch-off) and the output relay R2 (21-22/24) reacts to threshold value R2 (prewarning) 1 x 2 c/o (SPDT) contacts j If operating principle 1 x 2 c/o contacts is selected, both output relays R1 (11-12/14) and R2 (21-22/24) react synchronously to threshold value R1. Settings of the threshold value R2 have no effect on the operation. ERC CATALOG MEASURING AND MONITORING REL AYS 173 -- Insulation monitoring relays Technical diagrams 2CDC252085F0009, 2CDC 252 088 F0009 -- Wiring diagrams CM-IWS.1 Always connect L+ and L- to different conductors. L+ and L- can be connected to any of the conductors. Un 250 V AC; 300 V DC A1 11 KE S1 S2 S3 A1 11 KE S1 S2 S3 2CDC 252 085 F0009, 2CDC252082F0009 L N PE -- 2-wire AC system L+ L- w 14 12 A2 A1 11 KE S1 S2 S3 L1 L2 L3 PE -- 3-wire AC system L+ L- w 14 12 A2 A1 11 KE S1 S2 S3 2CDC252092F0009, 2CDC252089F0009 PWM L+ DC L- PE -- 2-wire DC system L+ L- w 14 12 A2 A1 11 KE S1 S2 S3 PWM L+ DC L- PWM L+ L+ M DC L- L- PE -- 3-wire DC system L+ L- w 14 12 A2 2CDC252099F0009, 2CDC252096F0009 L1 L2 L3 N PE -- 4-wire AC system L+ L- w 14 12 A2 2CDC252092F0009, 2CDC252095F0009 174 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical diagrams 2CDC252083F0009, 2CDC252082F0009 -- Wiring diagrams CM-IWS.2 L can be connected to any of the conductors. Un 400 V AC A1 11 S1 S2 S3 L N PE -- 2-wire AC system L w 14 12 A2 A1 11 S1 S2 S3 L1 L2 L3 PE -- 3-wire AC system L w 14 12 A2 A1 11 S1 S2 S3 L1 L2 L3 N PE -- 4-wire AC system L w 14 12 A2 2CDC252090F0009, 2CDC252089F0009 2CDC252097F0009, 2CDC252096F0009 ERC CATALOG MEASURING AND MONITORING REL AYS 175 -- Insulation monitoring relays Technical diagrams -- Wiring diagrams CM-IWN.1 Always connect L+ and L- to different conductors. L+ and L- can be connected to any of the conductors. Un 400 V AC; 600 V DC (For monitoring of systems with higher voltages, use coupling unit CM-IVN.) A1 11 21 S1 S2 S3 A1 11 21 S1 S2 S3 2CDC252086F0009, 2CDC252088F0009 2CDC252086F0009, 2CDC252082F0009 L N PE -- 2-wire AC system 12 14 L+ VS V1+ V1- 22 24 L- KE w A2 A1 11 21 S1 S2 S3 L1 L2 L3 PE -- 3-wire AC system 12 14 L+ VS V1+ V1- 22 24 L- KE w A2 A1 11 21 S1 S2 S3 2CDC252093F0009, 2CDC252089F0009 PWM L+ DC L- PE -- 2-wire DC system 12 14 L+ VS V1+ V1- 22 24 L- KE w A2 A1 11 21 S1 S2 S3 PWM L+ DC L- PWM L+ L+ M DC L- L- PE -- 3-wire DC system 12 14 L+ VS V1+ V1- 22 24 L- KE w A2 2CDC252093F0009, 2CDC252095F0009 2CDC252100F0009, 2CDC252096F0009 L1 L2 L3 N PE -- 4-wire AC system 12 14 L+ VS V1+ V1- 22 24 L- KE w A2 176 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical diagrams 2CDC252010F0016 -- Wiring diagrams CM-IWM.10 3 L1 L2 L3 PE L(+) L(-) PE KE CM-IWM.10 -- Example of a AC application CM-IWM.11 3 L1 L2 L3 PE L(+) L(-) *) G HM PE KE CM-IWM.11 *) G-HM connected: Measuring circuit is off -- Example of a AC application 2CDC252007F0016 2CDC252011F0016 L+ LPE L(+ ) L(-) 11-12/14: AL 21-22/24: VW PE KE CM-IWM.10 RG T Reset Test -- Example of a DC application A1+ A2 DC Power supply L+ LPE L(+ ) L(-) *) G HM PE KE 11-12/14: AL 21-22/24: VW CM-IWM.11 RG T Reset Test A1+ A2 DC Power supply *) G-HM connected: Measuring circuit is off -- Example of a DC application 2CDC252006F0016 ERC CATALOG MEASURING AND MONITORING REL AYS 177 -- Insulation monitoring relays Technical diagrams -- Dimensional drawings in mm and inches CM-IWS.x 113.4 4.47" 105.9 4.17" 22.5 0.89" 85.6 3.37" 2CDC252009F0011 -- CM-IWS.x Accessories 103.7 4.08" 6.5 0.256" 62.5 2.461" 60 2.362" 70 2.756" -- ADP.01 Adapter for screw mounting 10 0.394" 20 0.787" 2CDC252008F0010 11.5 0.453" 22.5 0.89" 8 0.32" 4.8 0.19" 68 2.68" 8 0.315" 2CDC252186F0005 3A11 20 0.787" front to back 110.5 4.31" -- -- MAR.01 Marker label for devices without DIP COV.11 Sealable transparent cover switches 2CDC252010F0011 178 ERC CATALOG MEASURING AND MONITORING REL AYS -- Insulation monitoring relays Technical diagrams -- Dimensional drawings in mm and inches CM-IWN.x 114.5 4.51" 107.0 4.21" 45.0 1.77" 85.6 3.37" 2CDC252022F0011 -- CM-IWN.x Accessories 104.8 4.13" 45 1.772" 35 1.378" 6.5 0.256" 60 2.362" 62.5 2.461" 70 2.756" -- ADP.02 Adapter for screw mounting 10 0.394" 20 0.787" 2CDC252009F0010 11.5 0.453" 45.0 0.89" 9.3 0.37" 5.75 0.23" 7.85 0.309" 2CDC252020F0011 22.2 0.874" 4T22 19.9 0.783" -- MAR.12 Marker label for devices with DIP switches front to back 111.8 4.40" -- COV.12 Sealable transparent cover 68 2.68" 2CDC252023F0011 ERC CATALOG MEASURING AND MONITORING REL AYS 179 180 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 181 -- Thermistor motor protection relays Table of contents 182 Benefits and advantages 183 Applications 184 Features 186 Offer overview 188 Operating controls 189 Selection table 190 Ordering details 193 Technical data 199 Technical diagrams 182 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Benefits and advantages The thermistor motor protection relays of the CM-MSx range protect motors with PTC sensors against high temperature. These sensors are incorporated in the motor windings, thus measuring the motor heat directly. Continuous operation By using thermistor motor protection relays from ABB, the down and commissioning time can be reduced. The relay is continuously monitoring the sensor circuit to detect short-circuit or interrupted i.e. wire faults, thus contributing to maintenance and time saving in case of faults. In addition, the clear error messages of the front LEDs makes it possible to distinguish between the various fault causes. Reliable in harsh conditions Direct motor protection through temperature monitoring of the motor winding offers 100 % motor protection, even under the most difficult ambient conditions. The ABB thermistor motor protection relays give you access to worldwide markets and are approved by local and international standards for many applications such as industry, renewable energies, the marine sector and dangerous and explosive environments. To prove that, the CM-MSS thermistor motor protection relays are certified according to ATEX Ex II (2) G and D for environments with explosive gas or dust loads. Easy installation Due to the compliance with the latest standards, there is no need to make any adjustments on the device. All relays come with two different connection possibilities - screw or push-in - to make any adjustments on the installation a breeze. Thanks to direct measurement of the motor temperature, dimensioning of the thermistor motor protection relay, considering the size of the motor, is not necessary. ERC CATALOG MEASURING AND MONITORING REL AYS 183 -- Thermistor motor protection relays Applications Direct temperature monitoring Generally, motor damage caused by overload or overheating situations can be prevented in different ways. Compared to the indirect temperature measuring which monitors the motor current, the temperature inside the motor can be measured by direct temperature measuring. This enables direct control and evaluation of different operating conditions: Therefore, the consequences from overheating, such as abrasion as well as electrical failures, can be prevented. The direct measuring principle is carried out by a combination of the thermistor motor protection relay and three PTC sensors which are installed directly in the motor by the manufacturer. Those 3 PTC sensors are placed directly at the thermal hotspots, the motor windings. Heavy duty starting Increased switching frequencys Single phase operation Phase unbalanced Operating conditions High ambient temperature Insufficient cooling Breaking operation Motor protection using current- and temperature-dependent protective devices IEC 60204 stipulates that motors must be protected from overheating at a rating of 0.5 kW and higher. The protection can be provided or executed by overload protection, overtemperature protection or current limiting. For motors with frequent starting and braking, and in environments where cooling may be impaired (e.g. by dust), it is recommended to use the overtemperature protection option in the form of a protective device coordinated with this mode of operation. On rotor-critical motors, overtemperature detection in the stator windings can lead to delayed and hence inadequate protection. In this case, the standards stipulate additional protection, e.g. by means of an overload relay. This combination of thermistor motor protection and an overload relay is recommended for full motor protection in case of frequent starting and braking of motors, irregular intermittent duty or excessive switching frequency. Operating mode The thermistor motor protection relays are used to monitor the temperature of motors or generators equipped with PTC sensors type A according to the latest product standard IEC 60947-8. The sensors are built-in into the motor windings, measuring the motor heating. In case of an increase of the temperature in the motor, the resistance of the PTC sensors increases as well. If the motor heats-up excessively (>2.83 k), the output relay(s) de-energize(s) and the corresponding LED displays the overtemperature. A short circuit and an interrupted wire within the sensor circuit can also be detected. A reset is only possible after cooling down of the motor (<1.1 k) or after a wire interruption, or a short circuit within the sensor circuit has been removed. A reset after tripping can be done manually with the Test / Reset button, externally with a push button between S1 and 1T2/2T2, or automatically by jumpering S1-1T2/2T2. 184 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Features Test function The test function is only possible when there is no fault. By pressing the front-face combined Test / Reset button, a system test routine is executed. If the function ,,Remote Test / Reset" (DIP switch 4) is activated, the system test routine is also possible via control input S1-T2 (S1-1T2/2T2*). After starting the test routine, the output relays de-energize. They remain de-energized until the Test / Reset button is pressed again or control input S1-T2 (S1-1T2/2T2*) is closed (remote reset). Short-circuit detection x If a short circuit is detected between the two lines of a sensor circuit, the output relay(s) de-energize(s) and the LEDs will display the specific error code. Dynamic interrupted wire detection During the operation, the device is permanently monitoring the measuring circuit. If the resistance in the measuring circuit rises, the device distinguishes if there is an overtemperature or an interrupted wire. Fault storage f, reset function The fault storage is designed as non-volatile (remanent). This means that after switch-off and return of the control supply voltage the device returns to the state it was prior to the switch-off. If there was no fault prior to the interruption of the control supply voltage, the device restarts automatically after re-applying control supply voltage. If there was a fault prior to the interruption, reset can be reset manually by the Test / Reset button or externally by remote reset between S1-T2 (S1-1T2/2T2*). With deactivated fault storage, reset can be made manually by the Test / Reset button, automatically by jumpering S1-T2 (S1-1T2/2T2*) or externally by remote reset between S1-T2 (S1-1T2/2T2*). Depending on the configuration of DIP switch 1, there are several possibilities to reset the device as shown in the picture. *CM-MSS.51 DIP switch 1 S1 1T2/2T2 e 1.) Front 2.) Remote 3.) A1-A2 f 1.) Front 2.) Remote 1.) Front S1 1T2/2T2 2.) A1-A2 1.) Front 1.) Auto- S1 1T2/2T2 Reset ERC CATALOG MEASURING AND MONITORING REL AYS 185 -- Thermistor motor protection relays Features Single and accumulative evaluation Single evaluation i If a fault occurs in the measuring circuit 1, output relay 1 (11-12/14) de-energizes. If a fault occurs in the measuring circuit 2, output relay 2 (21-22/24) de-energizes. Accumulative evaluation j In case of a fault in one of the two measuring circuits, both output relays de-energize synchronously. Bimetallic switches In some applications, bimetallic switches - such as Klixon - are used as sensors instead of PTC temperature sensors. Bimetallic switches are temperature and current dependent, normally closed contacts, and are available for different temperature ranges. Since bimetallic switches have almost no resistance below their opening temperature, short-circuit detection is not possible when bimetallic switches are used. I ATEX certification Suitably selected and adjusted devices are necessary for the safe operation of explosion-protected motors. Only the sensor line is conducted into the explosive atmosphere. The motor protection relay itself must be installed outside the potentially explosive atmospheres. Marking: II (2) G I II (2) D CM-MSS functionality video 186 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Offer overview CM-MSE · Auto reset · Connection of several sensors (max. 6 sensors connected in series) · Monitoring of bimetals · 1 n/o contact · Excellent cost / performance ratio CM-MSS 1) · Different types of contacts available - 1 x 2 c/o (SPDT) contacts - 2 x 1 c/o (SPDT) contact - 1 n/o and 1 n/c contact · 1 or 2 measuring circuits · Different types of reset functions - Automatic - Manual - Remote · Rated control supply voltages - 24 V AC/DC - 24-240 V AC/DC - 110-130 V AC, 220-240 V AC · Various approvals and marks (1) Depending on device the characteristics vary, for detailed overview see "Selection table" on page 189. ERC CATALOG MEASURING AND MONITORING REL AYS 187 188 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Operating controls Test / Reset button Test - only possible if/when the relay doesn't show any fault. Reset - only possible if measured value < switch-on resistance Marker label / DIP switches (depending on device) e.g. i Single evaluation 2 x 1 c/o (SPDT) contact j Accumulative evaluation 1 x 2 c/o (SPDT) contacts y Short-circuit detection de-activated x Short-circuit detection activated f Non-volatile fault storage activated e Non-volatile fault storage de-activated Remote Reset Remote Reset Remote Test/Reset Remote Test/Reset Indication of operational states with LEDs U: green LED - Status indication of control supply voltage V Control supply voltage applied F: red LED - Fault message R: yellow LED - Status indication of the output relay For detailed status and failure analysis, please see "LEDs, status information and fault messages". ERC CATALOG MEASURING AND MONITORING REL AYS 189 -- Thermistor motor protection relays Selection table CM-MSS.51S 1SVR730712R1300 CM-MSS.51P 1SVR740712R1300 CM-MSS.41S 1SVR730712R1200 CM-MSS.41P 1SVR740712R1200 CM-MSS.33S 1SVR730712R2200 CM-MSS.33P 1SVR740712R2200 CM-MSS.32S 1SVR730712R0200 CM-MSS.32P 1SVR740712R0200 CM-MSS.31S 1SVR730712R1400 CM-MSS.31P 1SVR740712R1400 CM-MSS.23S 1SVR730700R2200 CM-MSS.23P 1SVR740700R2200 CM-MSS.22S 1SVR730700R0200 CM-MSS.22P 1SVR740700R0200 CM-MSS.21S 1SVR730722R1400 CM-MSS.21P 1SVR740722R1400 CM-MSS.13S 1SVR730700R2100 CM-MSS.13P 1SVR740700R2100 CM-MSS.12S 1SVR730700R0100 CM-MSS.12P 1SVR740700R0100 CM-MSS.11S 1SVR730720R1400 CM-MSS.11P 1SVR740720R1400 1SVR550801R9300 1SVR550800R9300 Order code 1SVR550805R9300 CM-MSE CM-MSE Type CM-MSE Characteristics ATEX approval Number of sensor circuits Single or accumulative evaluation Number of LEDs Contacts 1 c/o (SPDT) contact 2 c/o (SPDT) contacts 1 n/o 1 n/c and 1 n/o 2 x 1 c/o or 1 x 2 c/o contacts, configurable Reset Manual Remote Auto Test button Functions Short-circuit detection Short-circuit detection, configurable Dynamic interrupted wire detection Non-volatile fault storage Non-volatile fault storage, configurable Rated control supply voltage Us 24 V AC 110-130 V AC 220-240 V AC 24-240 V AC/DC 24 V AC/DC 110-130 V AC, 220-240 V AC Connection type Push-in terminals Double-chamber cage connection terminals Screw nn nn nnnnnnnnnn 1111111111111111111111122 nn 3322223322223333333333 nnnn nnnn nnnnnn nnn nn nn nn nn nnnnnnnnnnnnnn nnnnnnnnnnnnnn n n n n n n n n n n n n n n n n n n n n n n n n n (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (2) (2) nnnnnnnnnn nn nn nn nn nn nnnnnn nnnn nnnnnnnnnn nn nnnn n n n nn nn nn nnnn nn nn nn nn nn nn n n n n n n n n n n n n n n n n n n n n n n nnn 1) For automatic reset, connect terminals S1 to T2. 2) For automatic reset, connect Terminals S1 to 1T2/2T2. 190 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Ordering details CM-MSS.12S CM-MSS.41S CM-MSS.51S 2CDC 251 014 V0014 2CDC 251 013 V0014 2CDC 251 004 V0014 Description The thermistor motor protection relay CM-MSS monitors the winding temperature and thus protects the motor from overheating, overload and insufficient cooling in accordance to the product standard IEC/EN 60947-8. -- Ordering details CM-MSx Characteristics See selection table S: screw connection P: push-in connection Type CM-MSE CM-MSE CM-MSE CM-MSS.11P CM-MSS.11S CM-MSS.12P CM-MSS.12S CM-MSS.13P CM-MSS.13S CM-MSS.21P CM-MSS.21S CM-MSS.22P CM-MSS.22S CM-MSS.23P CM-MSS.23S CM-MSS.31P CM-MSS.31S CM-MSS.32P CM-MSS.32S CM-MSS.33P CM-MSS.33S CM-MSS.41P CM-MSS.41S CM-MSS.51P CM-MSS.51S Order code 1SVR550805R9300 1SVR550800R9300 1SVR550801R9300 1SVR740720R1400 1SVR730720R1400 1SVR740700R0100 1SVR730700R0100 1SVR740700R2100 1SVR730700R2100 1SVR740722R1400 1SVR730722R1400 1SVR740700R0200 1SVR730700R0200 1SVR740700R2200 1SVR730700R2200 1SVR740712R1400 1SVR730712R1400 1SVR740712R0200 1SVR730712R0200 1SVR740712R2200 1SVR730712R2200 1SVR740712R1200 1SVR730712R1200 1SVR740712R1300 1SVR730712R1300 Weight (1 pc) kg (lb) 0.11 (0.24) 0.11 (0.24) 0.11 (0.24) 0.119 (0.263) 0.127 (0.280) 0.105 (0.231) 0.113 (0.249) 0.147 (0.324) 0.155 (0.342) 0.118 (0.260) 0.126 (0.278) 0.121 (0.267) 0.132 (0.291) 0.163 (0.359) 0.174 (0.384) 0.120 (0.265) 0.128 (0.282) 0.120 (0.265) 0.130 (0.287) 0.162 (0.357) 0.172 (0.379) 0.130 (0.287) 0.141 (0.311) 0.135 (0.298) 0.145 (0.320) ERC CATALOG MEASURING AND MONITORING REL AYS 191 -- Thermistor motor protection relays Ordering details - PTC temperature sensors C011 Temperature sensor example RPTC [] 104 103 102 101 TPTC [°C] -20 °C TNF - 20 K TNF - 5 K TNF TNF + 5 K TNF + 15 K 22CCDDCC25225026806F802F008208 Temperature sensor characteristics 1SVC 110 000 F0531 Description The PTC temperature sensors (temperature-dependent with positive temperature coefficient) are selected by the manufacturer of the motor depending on: · the motor insulation class according to IEC/EN 60034-11, · the special characteristics of the motor, such as the conductor cross-section of the windings, the permissible overload factor, etc. · special conditions prescribed by the user, such as the permissible ambient temperature, risks resulting from locked rotor, extent of permitted overload, etc. One temperature sensor must be embedded in each phase winding. For instance, in case of three-phase squirrel cage motors, three sensors are embedded in the stator windings. For polechanging motors with one winding (Dahlander connection), three sensors are also required. Pole-changing motors with two windings, however, require six sensors. If an additional warning is required before the motor is switched off, separate sensors for a correspondingly lower temperature must be embedded in the winding. They have to be connected to a second control unit. The sensors are suitable for embedding in motor windings with rated operating voltages of up to 600 V AC. Conductor length: 500 mm per sensor. A 14 V varistor can be connected in parallel to protect the sensors from overvoltage. Due to their characteristics, the thermistor motor protection relays can also be used with PTC temperature sensors of other manufacturers which comply with DIN44081 and DIN 44 082. -- Ordering details CM-MSS accessories Rated response temperature TNF Color coding Type 70 °C 80 °C white-brown white-white C011-701) C011-801) 90 °C green-green C011-901) 100 °C red-red C011-1001) 110 °C brown-brown C011-1101) 120 °C gray-gray C011-1201) 130 °C blue-blue C011-1301) 140 °C white-blue C011-1401) 150 °C black-black C011-1501) 160 °C blue-red C011-1601) 170 °C white-green C011-1701) 150 °C black-black C011-3-1502) 1) Temperature sensor C011, standard version acc. to DIN 44081 2) Triple temperature sensor C011-3 Order code GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0011 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110033R0008 Weight (1 pc) kg (lb) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.05 (0.11) 192 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Technical data - PTC temperature sensors C011 Characteristic data Cold-state resistance Warm-state resistance ± 5 up to 6 K of rated response temperature TNF Thermal time constant, sensor open1) Permitted ambient temperature Sensor type C011 50 -100 q at 25 °C 10 000 q < 5 s +180 °C Rated response temperature PTC resistance R from -20 ± tolerance TNF ± TNF °C to TNF - 20 K 70 w5 °C 80 w5 °C 90 w5 °C 100 w5 °C 110 w5 °C 120 w5 °C 130 w5 °C 140 w5 °C 150 w5 °C 160 w5 °C 170 w7 °C m 100 q PTC resistance R2) at PTC temperatures of: TNF - iTNF (UPTC 2.5 V) TNF + iTNF (UPTC 2.5 V) m 570 q M 570 q m 550 q M 1330 q m 570 q M 570 q 1) Not embedded in windings. 2) For triple temperature sensor take values x 3. TNF + 15 K (UPTC 7.5 V) M 4000 q - ERC CATALOG MEASURING AND MONITORING REL AYS 193 -- Thermistor motor protection relays Technical data - CM-MSS Data at Ta = 25 °C and rated values, unless otherwise indicated Type CM-MSS.x1 CM-MSS.x2 CM-MSS.x3 Supply circuit - Input circuit Rated control supply voltage Us A1-A2 24-240 V AC/DC 24 V AC/DC 220-240 V AC A2-A3 - - 110-130 V AC Rated control supply voltage Us tolerance -15...+10 % Rated frequency 15-400 Hz 50-60 Hz Electrical insulation between supply circuit and measuring circuit yes no yes Power failure buffering time 20 ms Supply circuit - Measuring circuit / Sensor circuit Number of circuits 1 (CM-MSS.51: 2) Sensor type PTC type A (DIN/EN 44081, DIN/EN 44082) Max. total resistance of sensors connected in series, cold state < 750 W Overtemperature monitoring switch-off resistance (relay de-energizes) switch-on resistance (relay energizes) 2.83 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 2.7 kW w 5%) 1.1 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 1.2 kW w 5%) Maximum voltage in sensor circuit 1.33 kW 2.5 V 4 kW 3.7 V y kW 5.5 V Maximum current in sensor circuit 3.7 mA Maximum sensor cable length 2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm² Accuracy within the rated control supply voltage tolerance 0.50 % (CM-MSS.12 /.13 /.22 /.23: 5 %) Accuracy within the temperature range 0.01 %/K (CM-MSS.12 /.13 /.22 /.23: 0.5 %/K) Repeat accuracy (constant parameters) on request Reaction time of the safety function < 100 ms Hardware fault tolerance (HFT) 0 Control circuit Control function see "Selection table CM-MSx range" Maximum no-load voltage 5.5 V Max. current 0.6 mA (CM-MSS.12 /.13 /.22 /.23: 1.2 mA) Maximum cable length 2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm² Indication of operational states Control supply voltage U LED green Relay status R LED yellow Fault message F LED red Output circuit Kind of output see "Selection table CM-MSx range" Operating principle closed-circuit principle Contact material AgNi alloy, Cd free Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC Minimum switching voltage / Minimum switching current 24 V / 10 mA Maximum switching voltage / Maximum switching current see data sheet Rated operating current Ie (IEC/EN 60947-5-1) AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC Rating (UL 508) utilization category B 300 (Control Circuit Rating Code) maximum rated operational voltage 300 V AC maximum continuous thermal current at B 300 5 A maximum making/breaking apparent power 3600/360 VA at B 300 general purpose rating 250 V AC - 4 A Mechanical lifetime 30 x 106 switching cycles Electrical lifetime at AC12, 230 V AC, 4 A 0.1 x 106 switching cycles Maximum fuse rating to achieve shortcircuit protection n/c contact 10 A fast-acting (CM-MSS.12, CM-MSS.13, CM-MSS.51: 6 A) n/o contact 10 A fast-acting 194 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Technical data - CM-MSS Type CM-MSS.x1 CM-MSS.x2 CM-MSS.x3 General data MTBF on request Duty time 100 % Dimensions see "Dimensional drawings" Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical / horizontal 10 mm (0.394 in) if switching current > 2 A Material of housing UL 94 V-0 Degree of protection housing IP50 terminals IP20 Electrical connection Screw connection technology Easy Connect Technology (push-in) Connection capacity finestrand with(out) wire end 1 x 0.5-2.5 mm² (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (7.08 lb.in) - Environmental data Ambient temperature ranges operation -25...+60 °C (-13...+140 °F) storage -40...+85 °C (-40...+185 °F) Damp heat, cyclic (IEC/EN 60068-2-30) 6 x 24 h cycle, 55 °C, 95 % RH Climatic class (IEC/EN 60721-3-3) 3K5 (no condensation, no ice formation) Vibration, sinusoidal 5-13.2 Hz: ±1 mm; 13.2-100 Hz: 0.7 g Shock Class 2 Isolation data Rated insulation voltage Ui Supply circuit / Measuring circuit1) 300 V AC (CM-MSS.x2: n/a) Supply circuit / Output circuits 300 V AC Measuring circuit (1) / Output circuits 300 V AC Output circuit 1 / Output circuit 2 300 V AC Rated impulse withstand voltage Uimp Supply circuit / Measuring circuit1) 4 kV (CM-MSS.x2: n/a) Supply circuit / Output circuits 4 kV Measuring circuit (1) / Output circuits 4 kV Output circuit 1 / Output circuit 2 4 kV Basic insulation Supply circuit / Measuring circuit1) 600 V AC (CM-MSS.x2: n/a) Supply circuit / Output circuits 600 V AC Measuring circuit (1) / Output circuits 600 V AC Output circuit 1 / Output circuit 2 300 V AC Protective separation (IEC/EN 61140, EN 50178) Supply circuit / Measuring circuit1) yes, up to 300 V Supply circuit / Output circuits yes (CM-MSS.x2: n/a) Measuring circuit (1) / Output circuits yes Output circuit 1 / Output circuit 2 no Pollution degree (IEC/EN 60664-1) 3 Overvoltage category (IEC/EN 60664-1) III (1) Potential of measuring circuit = Potential of control circuit Standards Product standard Low Voltage Directive EMC directive ATEX directive RoHS directive EN 60947-5-1, EN 60947-8 2014/35/EU 2014/30/EU 2014/34/EU (only ATEX variants, see "Selection table CM-MSx range") 2011/65/EU ERC CATALOG MEASURING AND MONITORING REL AYS 195 -- Thermistor motor protection relays Technical data - CM-MSS Type CM-MSS.x1 CM-MSS.x2 CM-MSS.x3 Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2, IEC/EN 60947-8 electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz) electrical fast transient / burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz surge IEC/EN 61000-4-5 Level 3, Installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-N conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz) voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 Class 3 harmonics and interharmonics IEC/EN 61000-4-13 Class 3 Additional interference immunity according to product standard IEC/EN 60255-1 (reference on IEC/EN 60255-26) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 10 V/m (80 MHz - 3 GHz) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 10 V at stated frequencies damped oscillatory waves IEC/EN 61000-4-18 Signal lines, symmetric coupling: 1 kV peak voltage Power supply, asymmetric coupling: 2.5 kV peak voltage Interference emissions IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B high-frequency radiated Germanischer Lloyd increased requirements in the emergency call frequency band 196 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Technical data - CM-MSE Data at Ta = 25 °C and rated values, unless otherwise indicated Type CM-MSE Supply circuit - Input circuit Rated control supply voltage Us power consumption 1SVR550805R9300 24 V AC approx. 1.5 A 1SVR550800R9300 110-130 V AC approx. 1.5 A 1SVR550801R9300 220-240 V AC approx. 1.5 A Rated control supply voltage Us tolerance Rated frequency -15...+10 % 50-60 Hz Measuring circuit Monitoring function T1-T2 temperature monitoring by means of PTC sensors Number of sensor circuits 1 Sensor circuit Sensor type PTC type A (DIN/EN 44081, DIN/EN 44082) Max. total resistance of sensors connected in series, cold state 1.0 kW Overtemperature monitoring switch-off resistance 2.0-3.0 kW (relay de-energizes) switch-on resistance (relay energizes) 1.2-1.65 kW Maximum voltage in sensor circuit 4 kW 5 V kW 15 V Maximum current in sensor circuit 2 mA Maximum sensor cable length 2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm² Reaction time <100 ms Output circuit Kind of output 13-14 1 n/o contact Operational principle closed-circuit principle (output relay de-energizes if the measured value exceeds/drops below the adjusted threshold) Maximum switching voltage 250 V Rated operating voltage Ue and rated operating current Ie AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A DC-13 (inductive) at 24 V 2 A AC Rating (UL 508) utilization category (Control Circuit Rating Code) B 300 maximum rated operational voltage 300 V AC maximum continuous thermal current at B 300 5 A maximum making/breaking apparent power at B 300 3600/360 VA general purpose rating 250 V AC - 4 A Mechanical lifetime 30 x 106 switching cycles Electrical lifetime at AC12, 230 V AC, 4 A 0.1 x 106 switching cycles Maximum fuse rating to achieve short-circuit protection n/c contact 10 A fast-acting n/o contact 10 A fast-acting General data Dimensions see "dimensional drawings" Duty cycle 100 % Mounting DIN rail (IEC/EN 60715) Mounting position any Degree of protection housing / terminals IP50 / IP20 Electrical connection Connecting capacity fine strand with wire end ferrule 2 x 1.5 mm² (2 x 16 AWG) fine strand without wire end ferrule 2 x 0.75-1.5 mm² (2 x 18-16 AWG) rigid 2 x 1-1.5 mm² (2 x 18-16 AWG) Stripping length 2 x 0.75-1.5 mm² (2 x 18-16 AWG) Tightening torque 0.6-0.8 Nm (5.31-7.08 lb.in) Environmental data Ambient temperature ranges Operation -20..+60 °C Storage -40...+85 °C Damp heat IEC/EN 60068-2-30 40 °C, 93 % RH, 4 days Vibration withstand IEC/EN 60062-2-6 10-57 Hz: 0.075 mm; 57-150 Hz: 1 g ERC CATALOG MEASURING AND MONITORING REL AYS 197 -- Thermistor motor protection relays Technical data - CM-MSE Type Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient /burst surge conducted disturbances, induced by radio-frequency fields Interference emission high-frequency radiated high-frequency conducted CM-MSE supply, measuring / output circuit 250 V between all isolated circuits 4 kV / 1.2 - 50 s 3 III IEC/EN 60947-5-1, IEC/EN 60947-8 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 61000-6-2, IEC/EN 60947-8 IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz) IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-N IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz) IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B 198 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Technical data -- LEDs, status information and fault messages CM-MSS Operational state Absence of control supply voltage Internal fault2) Internal fault2) Control supply voltage not within the tolerance range Short circuit Interrupted wire Measuring circuit 2: Overtemperature Measuring circuit 1: Overtemperature Fault rectified but not confirmed Test function Change of configuration not confirmed No fault U: green LED OFF OFF X X V V V V V X V V 1) Depending on the fault with the highest priority 2) Restart the device. If after restart the same fault is indicated, replace the device. F: red LED OFF W X V Y Z W V - 1) OFF OFF OFF R: yellow LED OFF W X OFF OFF OFF OFF OFF X OFF X V ERC CATALOG MEASURING AND MONITORING REL AYS 199 -- Thermistor motor protection relays Technical diagrams 2CDC 252 018 F0014 2CDC 252 022 F0014 2CDC 252 020 F0014 2CDC 252 047 F0014 -- Connection diagrams CM-MSS.11x, CM-MSS.21x A1 13 21 T2 T1 T1 A1 14 22 T2 A2 13 21 14 22 A2 A1 A2 13 14 21 22 T1 T2 Control supply voltage n/o contact n/c contact Measuring circuit CM-MSS.12x A1 11 T2 T1 T1 A1 11 T2 A2 12 14 14 12 A2 A1 A2 11 12/14 T1 T2 Control supply voltage c/o contact Measuring circuit CM-MSS.13x A1 11 A3 T2 T1 T1 A1 A3 11 T2 A2 12 14 CM-MSS.31x A1 13 21 S1 T2 T1 T1 A1 14 22 S1 T2 A2 13 21 14 12 A2 A1 A2 A2 A3 11 12/14 T1 T2 Control supply voltage 220-240 V AC Control supply voltage 110-130 V AC c/o contact Measuring circuit 14 22 A2 A1 A2 13 14 21 22 S1 T2 T1 T2 Control supply voltage n/o contact n/c contact Automatic reset (jumpered) Measuring circuit 2CDC 252 019 F0014 2CDC 252 021 F0014 2CDC 252 017 F0014 1SVC 110 000 F0140 CM-MSS.22x, CM-MSS.32x, CM-MSS.41x A1 11 21 T2 T1 T1 A1 11 21 S1 T2 A2 12 14 22 24 24 22 S1 14 12 A2 CM-MSS.23x, CM-MSS.33x A1 11 21 A3 T2 T1 T1 A1 A3 11 21 S1 T2 A2 12 14 22 24 24 22 S1 14 12 A2 A1 A2 11 12/14 21 22/24 S1 T2 T1 T2 Control supply voltage 24 V AC/DC 1st c/o (SPDT) contact 2nd c/o (SPDT) contact Automatic reset (jumpered) Measuring circuit A1 A2 A2 A3 11 12/14 21 22/24 S1 T2 T1 T2 Control supply voltage 220-240 V AC Control supply voltage 110-130 V AC 1st c/o (SPDT) contact 2nd c/o (SPDT) contact Automatic reset (jumpered) Measuring circuit CM-MSS.51x CM-MSE A1 11 21 1T1 1T2/2T2 2T1 1T1 A1 11 2T1 A1 21 S1 S1 1T2/2T2 A2 12 14 1T2/2T2 A2 22 24 24 22 S1 14 12 A2 A1 A2 Control supply voltage 220-240 V AC 11 12/14 1st c/o (SPDT) contact 21 22/24 2nd c/o (SPDT) contact S1 1T2/2T2 Automatic reset (jumpered) 1T1 1T2/2T2 Measuring circuit 1 2T1 1T2/2T2 Measuring circuit 2 A1 T1 T2 T1 A1 13 T2 A2 14 13 14 A2 A1 A2 T1-T2 13-14 Control supply voltage 24 V AC Sensor circuit Output contact Closed circuit principle 200 ERC CATALOG MEASURING AND MONITORING REL AYS -- Thermistor motor protection relays Technical diagrams 2CDC 252 025 F0014 -- Circuit diagrams CM-MSS.11x, CM-MSS.21x V+ A1 14 22 T1 M 3~ µC T2 t 21 13 A2 V- CM-MSS.12x V+ A1 T1 M 3~ T2 t A2 V- CM-MSS.13x V+ 11 A1 or A3 11 T1 M 3~ T2 t 14 14 12 12 A2 V- 2CDC 252 024 F0014 2CDC 252 023 F0014 CM-MSS.22x CM-MSS.23x CM-MSS.31x V+ V+ V+ A1 11 21 A1 or A3 11 21 A1 14 22 T1 T1 T1 M 3~ M 3~ M 3~ µC T2 t T2 t T2 t 24 24 21 22 22 13 Reset S1 A2 14 Reset 12 S1 A2 14 Reset 12 S1 A2 V- V- V- 2CDC 252 027 F0014 2CDC 252 026 F0014 CM-MSS.32x, CM-MSS.41x CM-MSS.33x CM-MSS.51x V+ V+ V+ A1 11 21 A1 or A3 11 21 A1 11 21 1T1 M 3~ M 3~ T1 µC M 3~ T1 µC t 1T2/ 2T2 µC 2CDC 252 029 F0014 2CDC 252 015 F0014 T2 t T2 t 24 24 M 3~ 24 22 22 2T1 22 Reset 14 Reset 14 t 14 12 12 12 S1 S1 A2 A2 V- V- Reset S1 A2 V- CM-MSE 2CDC 252 028 F0014 2CDC 252 016 F0014 1SVC 110 000 F0141 ERC CATALOG MEASURING AND MONITORING REL AYS 201 202 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 203 -- Temperature monitoring relays Table of contents 204 Benefits and advantages 205 Applications 207 Operating controls 208 Selection table 209 Ordering details 210 Configuration and setup 212 Technical data 215 Technical diagrams 216 Function diagrams 204 ERC CATALOG MEASURING AND MONITORING REL AYS -- Temperature monitoring relays Benefits and advantages The temperature monitoring relays of the CM-TCS range are able to measure temperatures of solids, liquids and gaseous media using PT100 sensors. Overtemperature and undertemperature monitoring, as well as open- or closed-circuit principle is configurable for all devices. As soon as the temperature falls below or exceeds the set threshold value, the output relays change their positions and the front-face LED`s display the current status. 24 7 Continuous operation By using temperature monitoring relays, both the downtime and the commissioning time can be reduced. The relay is continuously monitoring the sensor circuit to detect short-circuit or interrupted wire faults. The high accuracy of the measuring input leads to a fast detection of exceeding threshold values. In case of fault, maintenance effort is reduced and time saved. Reliable in harsh conditions Easy installation All relays work reliably in environments with low temperatures down to -40 °C. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable no matter the environment temperature but is also durable to shock and vibration. Save time as retightening is no longer needed and enhance the reliability and safety not only for the equipment. Like all devices from the measuring and monitoring portfolio, the CM-TCS relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. For further configuration options, additional settings can be made via dip-switches, offering the flexibility to configure, for example, the working principle of the relays and the output configuration. The device can be set up before installation in the application and easy adjustments during the process are possible. ERC CATALOG MEASURING AND MONITORING REL AYS 205 -- Temperature monitoring relays Applications The temperature monitoring relays CM-TCS monitor overtemperature, undertemperature, or temperatures between two threshold values (window monitoring) with a PT100 sensor. As soon as the temperature falls below or exceeds the threshold value, the output relays change their positions according to the configured functionality. The current status is displayed by frontfaced LEDs. Regardless of the selected configuration, the device is monitoring its measuring circuit for interrupted wires or shortcircuits. Control cabinet temperature monitoring Air Conditioning and ventilation systems (Machine) rooms, ball bearings Application examples Temperature control of eg. equipment and machines Refrigiation plants and coolants 206 ERC CATALOG MEASURING AND MONITORING REL AYS -- Reliable temperature monitoring for critical applications up to -50°C ERC CATALOG MEASURING AND MONITORING REL AYS 207 -- Temperature monitoring relays Operating controls Push-in and screw terminals Measuring input: PT100 Adjustment of the threshold value - 50 ... + 50 °C 0 ... + 100 °C 0 ... + 200 °C Adjustment of the hysteresis for threshold value 2 - 20 % Indication of operational states U: green LED status indication of control supply voltage t: red LED fault message, state of measuring input R: yellow LED status indication of the output relays DIP switch functions / marker label p Overtemperature monitoring q Undertemperature monitoring r Temperature window monitoring activated s Temperature window monitoring de-activated g Closed-circuit principle h Open-circuit principle i 2 x 1 c/o (SPDT) contact j 1 x 2 c/o (SPDT) contacts 208 ERC CATALOG MEASURING AND MONITORING REL AYS -- Temperature monitoring relays Selection table CM-TCS.13P 1SVR 740 740 R0300 CM-TCS.13S 1SVR 730 740 R0300 CM-TCS.23P 1SVR 740 740 R9300 CM-TCS.23S 1SVR 730 740 R9300 CM-TCS.12P 1SVR 740 740 R0200 CM-TCS.12S 1SVR 730 740 R0200 CM-TCS.22P 1SVR 740 740 R9200 CM-TCS.22S 1SVR 730 740 R9200 CM-TCS.11P 1SVR 740 740 R0100 CM-TCS.11S 1SVR 730 740 R0100 CM-TCS.21P 1SVR 740 740 R9100 CM-TCS.21S 1SVR 730 740 R9100 Order number Type Rated control supply voltage Us 24 V AC/DC 24-240 V AC/DC Sensor circuits (2 or 3 wire) Number of temperature sensors Number of thresholds Measuring temperature range -50...+50 °C 0...+100 °C 0...+200 °C Monitoring function Overtemperature Undertemperature Window temperature Operating principle open or closed-circuit principle Output contacts c/o JJ JJ JJ JJ JJ JJ 111111111111 222222222222 JJJJ JJJJ JJJJ JJJJJJJJJJJJ JJJJJJJJJJJJ JJJJJJJJJJJJ JJJJJJJJJJJJ 222222222222 ERC CATALOG MEASURING AND MONITORING REL AYS 209 -- Temperature monitoring relays Ordering details CM-TCS 2CDC 251 031 V0012 Description CM-TCS The temperature monitoring relays CM-TCS are able to measure temperatures of solids, liquids and gaseous media using PT100 sensors. Overtemperature and undertemperature monitoring, as well as open- or closed-circuit principle, is configurable for all devices. As soon as the temperature falls below or exceeds the set threshold value, the output relays change their positions according to the configured functionality and the front-face LEDs display the current status. -- Ordering details Temperature monitoring relays CM-TCS Rated control supply Measuring Temperature Type voltage range sensors Order code 24-240 V AC/DC 24 V AC/DC -50...+50 °C PT100 0...+100 °C 0...+200 °C -50...+50 °C 0...+100 °C 0...+200 °C S: screw connection P: push-in connection CM-TCS.11S CM-TCS.11P CM-TCS.12S CM-TCS.12P CM-TCS.13S CM-TCS.13P CM-TCS.21S CM-TCS.21P CM-TCS.22S CM-TCS.22P CM-TCS.23S CM-TCS.23P 1SVR730740R0100 1SVR740740R0100 1SVR730740R0200 1SVR740740R0200 1SVR730740R0300 1SVR740740R0300 1SVR730740R9100 1SVR740740R9100 1SVR730740R9200 1SVR740740R9200 1SVR730740R9300 1SVR740740R9300 Weight (1 pc) kg (lb) 0.151 (0.333) 0.140 (0.309) 0.151 (0.333) 0.140 (0.309) 0.151 (0.333) 0.140 (0.309) 0.138 (0.304) 0.127 (0.280) 0.138 (0.304) 0.127 (0.280) 0.138 (0.304) 0.127 (0.280) 210 ERC CATALOG MEASURING AND MONITORING REL AYS -- Temperature monitoring relays Configuration and setup -- DIP switches Position 4 3 2 1 ON i g r p OFF j h s q DIP switch 1 Monitoring principle DIP switch 2 Temperature window monitoring DIP switch 3 Operating principle of the output relays DIP switch 4 2 x 1 c/o contact, 1 x 2 c/o contacts ON Overtemperature monitoring p If overtemperature monitoring is selected, the CM-TCS recognizes temperatures above the selected threshold and trips the output relay according to the selected operating principle. Temperature window monitoring activated r If temperature window monitoring is selected, the CMTCS monitors over- and undertemperature. If temperature window monitoring is activated, DIP switch 1 is disabled. Closed-circuit principle g If closed-circuit principle is selected, the output relays are energized. They de-energize if a fault is occurring. 2 x 1 c/o (SPDT) contact i If operating principle 2 x 1 c/o contact is selected, the output relay R1 (11-12/14) reacts to threshold value t1 and the output relay R2 (21-22/24) reacts to threshold value t2. OFF (default) Undertemperature monitoring q If undertemperature monitoring is selected, the CMTCS recognizes temperatures below the selected threshold and trips the output relay according to the selected operating principle. Temperature window monitoring de-activated s Temperature window monitoring is de-selected. Open-circuit principle h If open-circuit principle is selected, the output relays are deenergized. They energize if a fault is occurring. 1 x 2 c/o (SPDT) contacts j If operating principle 1 x 2 c/o contacts is selected, both output relays R1 (11-12/14) and R2 (21-22/24) react synchronously to one threshold value. Overtemperature monitoring: Settings of the threshold value t2 have no effect on the operation. Undertemperature monitoring: Settings of the threshold values t2 have no effect on the operation. ERC CATALOG MEASURING AND MONITORING REL AYS 211 -- Temperature monitoring relays Configuration and setup -- Connection of resistance thermometer sensors 2-wire measurement When using 2-wire temperature sensors, the sensor resistance and the wire resistance are added together. The resulting systematic errors must be taken into account when adjusting the tripping device. A jumper must be connected between the terminals T2 and T3. The following table can be used for PT100 sensors to determine the temperature errors caused by the line length. When using resistance sensors with two-wire connection a bridge must be inserted between terminals T2 and T3. PT100 3-wire measurement To minimize the influence of the wire resistance, a three-wire connection is usually used. By means of the additional wire, two measuring circuits are created. One of these two circuits is used for reference. This way, the tripping device can calculate and take into account the wire resistance automatically. PT100 T1 T2 T3 T1 T2 T3 Temperature error (depending on the line length and conductor cross section for PT100 sensors at an ambient temperature of 20 °C, in K) Line length in m 0 10 25 50 75 100 200 500 Wire size mm² 0.50 0.75 0.0 0.0 1.8 1.2 4.5 3.0 9.0 6.0 13.6 9.0 18.1 12.1 36.3 24.2 91.6 60.8 1 0.0 0.9 2.3 4.5 6.8 9.0 18.1 45.5 1.5 0.0 0.6 1.5 3.0 4.5 6.0 12.1 30.2 Error caused by the line The error resulting from the line resistance amounts to approx. 2.5 Kelvin/Ohm. If the resistance of the line is not known and it is not possible to measure it, the error caused by the line can be estimated using the following table. 212 ERC CATALOG MEASURING AND MONITORING REL AYS -- Temperature monitoring relays Technical data Type CM-TCS.11/12/13 CM-TCS.21/22/23 Input circuit Rated control supply voltage Us A1-A2 24-240 V AC/DC 24 V AC/DC Rated control supply voltage Us tolerance -15...+10 % Typical current / power / consumption 24 V DC 33 mA / 0.8 VA 18 mA / 0.45 VA 115 V AC 12.5 mA / 1.5 VA n/a 230 V AC 13 mA / 2.9 VA n/a Rated frequency AC 15-400 Hz 50/60 Hz Frequency range AC 13.5-440 Hz 45-65 Hz Power failure buffering time min. 20 ms Measuring circuit T1, T2, T3 Sensor type PT100 Connection of the sensor 2-wire yes, jumper between T2-T3 3-wire yes, use terminal T1, T2, T3 Monitoring function overtemperature, undertemperature or window monitoring Threshold values adjustable within the measuring range CM-TCS.x1 -50...+50 °C CM-TCS.x2 0...+100 °C CM-TCS.x3 0...+200 °C Number of possible thresholds 2 Tolerance of the adjusted threshold value typ. ±5 % of the range end value Hysteresis related to the threshold value 2-20 % of threshold value, min. 1 °C Measuring principle continuous current Typical current in the sensor circuit 0.8 mA Maximum current in sensor circuit 0.9 mA Interrupted wire detection yes, indicated via LED status Short-circuit detection yes, indicated via LED status Accuracy within the rated control supply voltage tolerance < 0.2 °C / or < 0.01 %/K Accuracy within the temperature range < 0.2 °C / or < 0.01 %/K Repeat accuracy (constant parameters) < 0.2 % of full scale Maximum measuring cycle 320 ms Output circuit Kind of output 2 x 1 or 1 x 2 c/o (SPDT) contacts configurable Operating principle open- or closed-circuit principle configurable (1) Contact material AgNi alloy, Cd free Minimum switching voltage / Minimum switching current 24 V / 10 mA Maximum switching voltage / Maximum switching current see `Load limit curves' Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) 230 V 4 A AC-15 (inductive 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC Rating (UL508) utilization category B 300 pilot duty; general purpose 250 V, 4 A, cos 0.75 maximum rated operational voltage 250 V AC maximum continuous thermal current at B 300 4 A maximum making/breaking apparent 3600/360 VA power at B 300 Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Maximum fuse rating to achieve short-circuit protection n/c contact 6 A fast-acting n/o contact 10 A fast-acting Conventional thermal current Ith 4 A (1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value ERC CATALOG MEASURING AND MONITORING REL AYS 213 -- Temperature monitoring relays Technical data Type General data Dimensions Mounting Mounting position Degree of protection Ambient temperature range CM-TCS.11/12/13 CM-TCS.21/22/23 see "dimensional drawings" DIN rail (IEC/EN 60715), snap-on mounting without any tool any enclosure / terminals IP50 / IP20 operation -40...+60 °C storage /transport -40...+85 °C Electrical connection Wire size fine-strand without wire end ferrule fine-strand with wire end ferrule rigid Stripping length Tightening torque Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Environmental data Ambient temperature ranges Climatic class Damp heat, cyclic Vibration, sinusoidal Shock Isolation data Rated impulse withstand voltage Uimp Rated insulation voltage Ui Screw connection technology A1, A2, 11, 12, 14, 21, 22, 24 1 x 0.5-2.5 mm² (1 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) T1, T2, T3 1 x 0.2-2.5 mm² (1 x 24-14 AWG) 2 x 0.2-1.5 mm² (2 x 24-16 AWG) A1, A2, 11, 12, 14, 21, 22, 24 1 x 0.5-2.5 mm² (1 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) T1, T2, T3 1 x 0.2-2.5 mm² (1 x 24-14 AWG) 2 x 0.2-1.5 mm² (2 x 24-16 AWG) A1, A2, 11, 12, 14, 21, 22, 24 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) T1, T2, T3 1 x 0.2-4 mm² (1 x 24-12 AWG) 2 x 0.2-2.5 mm² (2 x 24-14 AWG) 8 mm (0.32 In) < 0.5 mm² 0.5 Nm (4.43 lb.In) 0.5 mm² 0.6 - 0.8 Nm (5.31 - 7.08 lb.In) Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) connection with lever 2 x 0.2-1.5 mm² (2 x 24-16 AWG) connection with lever 2 x 0.5-1.5 mm² (2 x 20-16 AWG) connection: push-in 2 x 0.2-1.5 mm² (2 x 24-16 AWG) insulated ferrule (DIN 46228-4-E): connection: push-in ferrule (DIN 46228-1-A): < 0.5 mm², connection with lever 0.5 mm², connection: push-in 2 x 0.5-1.5 mm² (2 x 20-16 AWG) connection: push-in 2 x 0.2-1.5 mm² (2 x 24-16 AWG) < 0.5 mm², connection with lever 0.5 mm², connection: push-in - IEC/EN 60255-27, IEC/EN 60947-5-1 2014/35/EU 2014/30/EU 2011/65/EU operation/storage/ transport -40...+60°C/-40...+85°C/-40...+85°C IEC/EN 60721-3-3 3K5 (no condensation, no ice formation) IEC/EN 600068-2-30 6 x 24 h cycle, 55 °C, 95 % RH Class 2 Class 2 supply circuit / 4 kV - measuring circuit supply circuit / output circuits 4 kV measuring circuit / 4 kV output circuits output circuit 1 / 4 kV output circuit 2 supply circuit / 300 V - measuring circuit supply circuit / output circuits 300 V measuring circuit / 300 V output circuits output circuit 1 / 300 V output circuit 2 214 ERC CATALOG MEASURING AND MONITORING REL AYS -- Temperature monitoring relays Technical data Type Basis insulation Protective separation (IEC/EN 61140, EN 50178) Pollution degree Overvoltatge category Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted CM_TCS.11/12/13 supply circuit / 250 V AC / 300 V DC measuring circuit supply circuit / output circuits 250 V AC / 300 V DC measuring circuit / 250 V AC / 300 V DC output circuits output circuit 1 / 250 V AC / 300 V DC output circuit 2 supply circuit / 250 V AC / 250 V DC measuring circuit supply circuit / output circuits 250 V AC / 300 V DC measuring circuit / 250 V AC / 300 V DC output circuits 3 III CM-TCS.21/22/23 - 250 V AC / 250 V DC 250 V AC / 250 V DC IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz) IEC/EN 61000-4-4 Level 3, 2 KV / 5 kHz IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth IEC/EN 61000-4-6 Level 3, 10 V IEC/EN 61000-4-11 Class 3 IEC/EN 61000-4-13 Class 3 IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B ERC CATALOG MEASURING AND MONITORING REL AYS 215 -- Temperature monitoring relays Technical diagrams 85,6 33,70" -- Connection diagram A 1 11 21 T3 T2 T1 T1 T2 T3 11 21 A1 A2 12 14 22 24 2CDC 252 025 F0010 24 22 14 12 A2 A1 A2 11 12/14 21 22/24 T1, T2, T3 Control supply voltage Output relay R1 Output relay R2 Measuring input, connection PT100 -- Dimensional drawing in mm and inches 113,4 44,65" 105,9 41,69" 22,5 0,89" CM-TCS.xxx 103,7 40,83" 2CDC252009F0011 -- Electrical isolation CM-TCS.2x 11 12 14 T1 21 T2 22 T3 24 24 V AC/DC A1 A2 Electrical isolation 2CDC 252 019 F0010 2CDC 252 020 F0010 CM-TCS.1x 11 12 14 T1 21 T2 22 T3 24 24-240 V AC/DC A1 A2 Protective separation acc. to IEC/EN 61140; EN 50178 216 ERC CATALOG MEASURING AND MONITORING REL AYS -- Temperature monitoring relays Function diagrams A1-A2 Threshold 1 Hysteresis Measured value Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED A1-A2 Threshold 1 Hysteresis Threshold 2 Hysteresis Measured value Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED A1-A2 Measured value Hysteresis Threshold 2 Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED 2CDC 252 009 F0209 2CDC 252 010 F0209 2CDC 252 008 F0209 Overtemperature monitoring, 1 x 2 c/o contacts j With this configuration, settings via t2 have no influence on the operating function (t2 disabled). Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t1, the output relays energize. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis, the output relays de-energize. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. Overtemperature monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t2, output relay R2 (prewarning) energizes. If the measured value exceeds the adjusted threshold value t1, output relay R1 (final switch-off) energizes. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis, output relay R1 (final switch-off) de-energizes. If the measured value drops below the adjusted threshold value t2 minus the adjusted hysteresis, output relay R2 (prewarning) de-energizes. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. Undertemperature monitoring, 1 x 2 c/o contacts j With this configuration, settings via t1 have no influence on the operating function (t1 disabled). Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value drops below the adjusted threshold value t2, the output relays energize. If the measured value exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, the output relays de-energize. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. ERC CATALOG MEASURING AND MONITORING REL AYS 217 -- Temperature monitoring relays Function diagrams A1-A2 Measured value Hysteresis Threshold 1 Hysteresis Threshold 2 Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED A1-A2 Threshold 1 Hysteresis Measured value Hysteresis Threshold 2 Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED A1-A2 Threshold 1 Hysteresis Measured value Hysteresis Threshold 2 Open-circuit principle open 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED Closed-circuit principle closed 11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED 2CDC 252 013 F0209 2CDC 252 012 F0209 2CDC 252 011 F0209 Undertemperature monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value drops below the adjusted threshold value t1, output relay R1 (prewarning) energizes. If the measured value drops below the adjusted threshold value t2, output relay R2 (final switch-off) energizes. If the measured value exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, output relay R2 (final switch-off) de-energizes. If the measured value exceeds the adjusted threshold value t1 plus the adjusted hysteresis, output relay R1 (prewarning) de-energizes. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. Temperature window monitoring, 1 x 2 c/o contacts j Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t1 or drops below the adjusted threshold value t2, the output relays energize. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis or exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, the output relays de-energize. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. Temperature window monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t1 or drops below the adjusted threshold value t2, output relay R1 (> t1) or R2 (< t2) respectively energizes. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis or exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, output relay R1 (>t1) or R2 (<t2) respectively de-energizes. Closed-circuit principle: The behavior is inverse to the one with open-circuit principle. 218 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 219 -- Liquid level monitoring relays Table of contents 220 Benefits and advantages 222 Applications 226 Operating controls 228 Selection table 229 Ordering details 230 Technical data 236 Function diagrams 237 Technical diagrams 220 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Benefits and advantages ABB's liquid level monitoring relays are the ideal solution to regulate and control liquid levels and ratios of mixtures of conductive fluids. The assortment includes single- or multifunctional devices which can be used for overflow protection, dry-running protection of pumps, filling and draining applications as well as max. and min. level alarming. Global availability The liquid level monitoring relays are designed to provide a wide supply voltage range, making global differences irrelevant. Additionally, the CM-ENS range meets a broad range of standards and requirements. Together with ABB's global support and sales network, using CM-ENS gives customers the confidence of worldwide sourcing no matter where they build, install or operate their equipment. Reliable in harsh conditions High immunity against electromagnetic disturbances is ensured due to advanced measuring technology. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable no matter the environment temperature but is also durable to shock and vibration. Save time as re-tightening is no longer needed and enhance the reliability and safety not only for the equipment. Improve installation efficiency Like all devices from the measuring and monitoring portfolio, the CM-ENS relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. The device can be set up before installation in the application and easy adjustments during the process are possible. ERC CATALOG MEASURING AND MONITORING REL AYS 221 -- Liquid level monitoring relays Benefits and advantages Operating principle Liquid level control relays CM-ENS are designed to monitor levels of conductive liquids and media and is used, for example, for liquid level control in pump systems. The measuring principle is based on the resistance change sensed by single-pole electrodes. To avoid electrolytic phenomena, an AC current runs across the probes. A selector switch on the front panel allows selection of the required function and the sensitivity range. Suitability Suitable for spring water drinking water sea water sewage acids, bases liquid fertilizers milk, beer, coffee non-concentrated alcohol Not suitable for chemically pure water fuel oils explosive areas (liquid gas) ethylene glycol concentrated alcohol paraffin lacquers Characteristics CM-ENS.1x · Control of one or two liquid levels (min/max) · Fill or drain function · Adjustable response sensitivity 5-100 k CM-ENS.2x · Control of one or two liquid levels (min/max) · Fill (UP) or Drain (DOWN), adjustable via front-face potentiometer · Adjustable response sensitivity 0.1-1000 k CM-ENS.31 · Control of one or two liquid levels (min/max) · Fill (UP) or Drain (DOWN), adjustable via front-face potentiometer · Adjustable response sensitivity 0.1-1000 k · Selectable ON- or OFF-delay · 2 c/o (SPDT) contacts All CM-ENS devices · Devices with wide rated control supply voltage 24-240 V AC/DC · Cascadable · High EMC immunity · 3 LEDs for the indication of operational states · Screw connection technology or Easy Connect Technology · Housing material for highest fire protection classification UL 94 V-0 · Tool-free mounting and demounting on DIN rail · 22.5 mm (0.89 in) width 222 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Applications Liquid level monitoring relays work in conjunction with, for example, suspension electrodes, and can be used either for direct liquid level control or also for cascading devices, as well as operation modes with several electrodes, or control of two liquid levels are possible. 1SVC 110 000 F0478 Suspension electrode ERC CATALOG MEASURING AND MONITORING REL AYS 223 -- Liquid level monitoring relays Applications -- Cascading of several devices With the CM-ENS it is possible to use two devices in one tank. This enables the possibility to realize a pre-warning with additional electrodes. In this way, two additional alarm outputs for exceeding or dropping below the normal level can be implemented in addition to the filling levels MAX and MIN. In addition, a reserve pump can be connected to the additional device. Pump control Alarm, empty Device A C MAX MIN Device B C MAX MIN Pump control Reserve pump for filling Device A C MAX MIN Device B C MAX MIN Pump control Alarm, full Device A C MAX MIN Device B C MAX MIN Alarm Pump control Device A C MAX MIN Reserve pump for draining Device B C MAX MIN Reserve pump Alarm Filling with alarm empty Reserve pump Filling with reserve pump Draining with alarm full Draining with reserve pump Control pump 2CDC 252 015 F0215 Control pump 2CDC 252 016 F0215 Control pump 2CDC 252 017 F0215 Control pump 2CDC 252 018 F0215 2CDC252013F0015 Operating mode with three electrodes The CM-ENS measures the electrical resistance of the liquid between two immersion electrodes and a reference electrode. For CM-ENS.1x only: If the relay is connected to the rated control supply voltage, the output relay changes its switching state as soon as the liquid level reaches the MAX-electrode, while the minimum sensor is submerged. The relay returns to the original state as soon as the minimum sensor is no longer in contact with the monitored medium. For CM-ENS.2x and CM-ENS.31 only: The function fill () or drain () can be selected via a front-face potentiometer. If the fill function is selected, the output relay is energized until the MAX-electrode becomes wet. Then it is de-energized and not re-energized until the MIN-electrode becomes dry. If the drain function is selected, the output relay energizes as soon as the MAX-electrode becomes wet. It remains energized until the liquid level has dropped below the MIN-electrode. Operation mode with three electrodes Operation mode with two electrodes If only one level should be controlled, only the MAX-electrode shall be connected at the CM-ENS. 2CDC252073F0004 Operation mode with two electrodes 224 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Applications -- Control of two liquid levels via liquid level monitoring relay CM-ENS In combination with suspension electrodes CM-HC or CM-HCT (suitable for drinking water). Max 10 20 30 1k 10k 4 5 6 7 Min ERC CATALOG MEASURING AND MONITORING REL AYS 225 -- Liquid level monitoring relays Applications -- Overflow protection via liquid level monitoring relay CM-ENS In combination with the compact support CM-KH-3 and 3 bar electrodes CM-SE. 10 20 30 Max 1k 10k 4 5 6 7 Min 226 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Operating controls -- CM-ENS.1x Adjustment of the response sensitivity Marker label -- CM-ENS.2x Adjustment of the function Fill Drain Adjustment of the response sensitivity range Adjustment of the response sensitivity Marker label Indication of operational 40 states with LEDs 50 60 70 U: green LED - Status indication of control supply voltage V control supply voltage applied R: yellow LED - Status indication of the output relays V energized MIN/MAX: yellow LED - Status indication of the electrodes V MIN and MAX wet W MIN wet 1k Indication of operational 10k 4 states with LEDs 5 6 U: green LED - Status indication of 7 control supply voltage V control supply voltage applied R: yellow LED - Status indication of the output relays V energized MIN/MAX: yellow LED - Status indication of the electrodes V MIN and MAX wet W MIN wet ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Operating controls -- CM-ENS.31 Adjustment of the time delay 10 20 30 Adjustment of the function A ON-delayed Fill 1k A ON-delayed Drain 10k 4 B OFF-delayed Fill 5 6 B OFF-delayed Drain 7 Adjustment of the response sensitivity range Adjustment of the response sensitivity 227 Indication of operational states with LEDS U: green LED - Status indication of control supply voltage V control supply voltage applied W time delay is running R: yellow LED - Status indication of the output relays V energized MIN/MAX: yellow LED - Status indication of the electrodes V MIN and MAX wet W MIN wet Marker label 228 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Selection table CM-ENS.31P 1SVR 740 850 R0300 CM-ENS.31S 1SVR 730 850 R0300 CM-ENS.23P 1SVR 740 850 R2200 CM-ENS.23S 1SVR 730 850 R2200 CM-ENS.21P 1SVR 740 850 R0200 CM-ENS.21S 1SVR 730 850 R0200 CM-ENS.13P 1SVR 740 850 R2100 CM-ENS.13S 1SVR 730 850 R2100 CM-ENS.11P 1SVR 740 850 R0100 CM-ENS.11S 1SVR 730 850 R0100 CM-ENE MAX 1SVR 550 851 R9400 CM-ENE MAX 1SVR 550 850 R9400 CM-ENE MAX 1SVR 550 855 R9400 CM-ENE MIN 1SVR 550 851 R9500 CM-ENE MIN 1SVR 550 850 R9500 CM-ENE MIN 1SVR 550 855 R9500 Order code Type Rated control supply voltage Us 24-240 V AC/DC 24 V AC 110-130 V AC 220-240 V AC Sensor circuit Number of electrodes (including ground reference) Response sensitivity range 0-100 kOhm 5-100 kOhm 0.1-1000 kOhm Monitoring function Dry running protection Overflow protection Liquid level control Operating principle Open-circuit principle Closed-circuit principle Open- or closed-circuit principle Adjustable ON-/OFF-delay 0.1-10 s Output contacts n/o c/o (SPDT) Connection type Push-in terminals Double-chamber cage connection terminals Screw adj: adjustable sel: selectable JJ JJ JJ J J J J JJ JJ J J JJ JJ 2222223333333333 JJJJJJ adj adj adj adj adj adj adj adj adj adj JJJ JJJJJJJJJJ JJJJJJJJJJJJJ JJJJJJJJJJJJJ JJJ JJJJ JJJ sel sel sel sel sel sel JJ 111111 1111111122 JJJJJ JJJJJ JJJJJJ ERC CATALOG MEASURING AND MONITORING REL AYS 229 -- Liquid level monitoring relays Ordering details CM-ENE MIN CM-ENS.3x 1SVR 550 851 F9500 2CDC 251 004 V0015 Description The liquid level monitoring relays CM-ENS and CM-ENE monitors and controls the liquid level and ratios of mixtures of conductive fluids. It is used for filling and draining applications, to protect pumps against dry-running, to protect tanks against overflow, and for signalization of the status of the monitored liquid level. -- Ordering details Characteristics Type See selection table CM-ENE MIN CM-ENE MAX CM-ENS.11S CM-ENS.11P CM-ENS.13S CM-ENS.13P CM-ENS.21S CM-ENS.21P CM-ENS.23S CM-ENS.23P CM-ENS.31S CM-ENS.31P Order code 1SVR550855R9500 1SVR550850R9500 1SVR550851R9500 1SVR550855R9400 1SVR550850R9400 1SVR550851R9400 1SVR730850R0100 1SVR730850R2100 1SVR740850R0100 1SVR740850R2100 1SVR730850R0200 1SVR740850R0200 1SVR730850R2200 1SVR740850R2200 1SVR730850R0300 1SVR740850R0300 Weight (1 pc) kg (lb) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.124 (0.273) 0.117 (0.258) 0.153 (0.337) 0.145 (0.320) 0.125 (0.276) 0.117 (0.258) 0.154 (0.340) 0.147 (0.324) 0.143 (0.315) 0.134 (0.295) 230 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Technical data Type CM-ENE MIN Supply circuit Rated control supply voltage US power consumption A1-A2 24 V AC, approx. 1.5 VA A1-A2 110-130 V AC, approx. 1.2 VA A1-A2 220-240 V AC, approx. 1.4 VA Rated control supply voltage US tolerance -15...+15 % Rated frequency 50-60 Hz Measuring circuit MIN-C, MAX-C Monitoring function dry-running protection Response sensitivity 0-100 kq, not adjustable Maximum electrode voltage 30 V AC Maximum electrode current 1.5 mA Electrode supply line max. cable capacity 3 nF max. cable length 30 m Timing circuit Tripping delay fixed approx. 200 ms Indication of operational states Output relay energized R: yellow LED Output circuits 13-14 Kind of output 1 n/o contact Operational principle1) open-circuit principle1) Rated operational voltage Ue (IEC/EN 60947-1) 250 V Minimum switching voltage / minimum switching current - / - Maximum switching voltage 250 V Rated operational voltage Ue and rated operational current Ie AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category B 300 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 VA Mechanical lifetime 30 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.3 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c contact n/o contact 10 A fast-acting General data Duty cycle 100 % Dimensions see dimensional drawings Mounting DIN rail (IEC/EN 60715) Mounting position any Degree of protection enclosure / terminals IP50 / IP20 Ambient temperature range operation / storage -20...+60 °C / -40...+85 °C Electrical connection Wire size fine-strand with wire-end ferrule 2 x 0.75-1.5 mm² (2 x 18-16 AWG) fine-strand without wire-end ferrule 2 x 1-1.5 mm² (2 x 18-16 AWG) rigid 2 x 0.75-1.5 mm² (2 x 18-16 AWG) Stripping length 10 mm (0.39 inch) Tightening torque 0.6-0.8 Nm CM-ENE MAX overflow protection closed-circuit principle1) ERC CATALOG MEASURING AND MONITORING REL AYS 231 -- Liquid level monitoring relays Technical data Type CM-ENE MIN Standards / Directives Standard IEC/EN 60947-5-1, EN 50178 Low Voltage Directive 2014/35/EU EMC Directive 2014/35/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to EN 61000-6-2, EN 61000-6-4 Electrostatic discharge IEC/EN 61000-4-2 level 3 (6 kV / 8 kV) Radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) Electrical fast transient / burst IEC/EN 61000-4-4 level 3 (2 kV / 5 kHz) Surge IEC/EN 61000-4-5 level 4 (2 kV L-L) Conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3 (10 V) Interference emission high-frequency radiated IEC/CISPR 22, class B EN 55022 high-frequency conducted IEC/CISPR 22, class B EN 55022 Environmental data Ambient temperature ranges operation/storage -20..+60 °C / -40...+85 °C Damp heat IEC/EN 60068-2-30 40 °C, 93 % RH, 4 days Vibration withstand IEC/EN 60068-2-6 10-57 Hz: 0.075 mm; 57-150 Hz: 1 g Isolation data Rat. insulation volt. betw. supply, measuring & output circuit 250 V Rated impulse withstand voltage Uimp between all isolated circuits 4 kV / 1.2-50 µs Pollution category 3 Overvoltage category III 1) Open-circuit principle: Output relay energizes if the measured value exceeds/drops below the adjusted threshold. Closed-circuit principle: Output relay de-energizes if the measured value exceeds/drops below the adjusted threshold. CM-ENE MAX 232 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Technical data Type Supply circuit Rated control supply voltage US CM-ENS.1x CM-ENS.11, CM-ENS.21, CM-ENS.31: A1-A2 24-240 V AC/DC CM-ENS.13, CM-ENS.23: A1-A2 220-240 V AC CM-ENS.2x CM-ENS.31 Rated control supply voltage US tolerance Rated frequency Frequency range Typical current / power consumption Power failure buffering time Start-up time ts Measuring circuit Sensor type Monitoring function Measuring principle Number of electrodes Response sensitivity Maximum electrode voltage Maximum electrode current Electrode supply line Max. measuring cycle Timing circuit Time delay Indication of operational states Control supply voltage Output relay energized CM-ENS.13, CM-ENS.23: A3-A2 110-130 V AC -15...+10 % 50-60 Hz 47-63 Hz 24 V AC 25 mA / 0.6 W 25 mA / 0.6 W 25 mA / 0.6 W 110-130 V AC 20 mA / 2.6 VA 20 mA / 2.6 VA 8 mA / 1.1 VA 220-240 V AC 8.5 mA / 2.1 VA 8.5 mA / 2.1 VA 10 mA / 2.4 VA 24-240 V AC/DC 11 mA / 2.6 VA 11 mA / 2.6 VA 11 mA / 2.6 VA min. 20 ms Range 5-100 k max. 1.3 s - - Range 0.1-1 k - max. 900 ms Range 1-10 k - max. 900 ms Range 10-100 k - max. 1.3 s Range 100-1000 k - max. 6.3 s MAX-MIN-C electrode fill or drain fill or drain, selectable conductivity measurement 3 adjustable: 5-100 k adjustable: 0.1-1000 k 6 V AC 1 mA 2 mA max cable max cable max cable max cable max cable max capacity length capacity length capacity cable length Range 5-100 k 10 nF 100 m - - - - Range 0.1-1 k - - 200 nF 1000 m 200 nF 1000 m Range 1-10 k - - 200 nF 1000 m 200 nF 1000 m Range 10-100 k - - 20 nF 100 m 20 nF 100 m Range 100-1000 k - - 4 nF 20 m 4 nF 20 m Range 5-100 k 1000 ms - - Range 0.1-1 k - 700 ms Range 1-10 k - 700 ms Range 10-100 k - 1.1 s Range 100-1000 k - 5 s - 0.1-30 s, adjustable, ON- or OFF-delay U: green LED R: Yellow LED ERC CATALOG MEASURING AND MONITORING REL AYS 233 -- Liquid level monitoring relays Technical data Type CM-ENS.1x CM-ENS.2x CM-ENS.31 Electrode / alarm status MAX/MIN: Yellow LED Output circuits Kind of output 1115-1216/1418 relay, 1 c/o (SPDT) contact relay, 1st c/o (SPDT) contact 2115-2216/2418 - relay, 2nd c/o (SPDT) contact Operational principle open-circuit principle open- or closed-circuit principle (selectable) Contact material AgNi alloy, Cd free Minimum switching voltage / minimum switching current 12 V / 10 mA Maximum switching voltage / Maximum switching current see data sheets Rated operational voltage Ue and rated operational current Ie (IEC/EN 60947-5-1) AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A DC-12 (resistive) 24 V 4 A DC-13 (inductive) 24 V 2 A AC rating (UL 508) Utilization category B 300, pilot duty general purpose 250 V, 4 A, cos 0.75 (Control Circuit Rating Code) max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 VA Mechanical lifetime 10 x 106 switching cycles Electrical lifetime (AC-12, 230 V, 4 A) 0.1 x 106 switching cycles Max. fuse rating to achieve short-circuit protection n/c / n/o contact 6 A / 10 A fast-acting 10 A / 10 A fastacting Conventional thermal current Ith 4 A 234 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Technical data Type General data MTBF Duty cycle Dimensions Weight Mounting Mounting position Minimum distance to other units Degree of protection Material of housing Electrical connection Wire size Stripping length Tightening torque Standards / Directives Standard Low Voltage Directive RoHS Directive EMC Directive Environmental data Ambient temperature ranges Damp heat, cyclic (IEC/EN 60068-2-30) Climatic category (IEC/EN 60721-3-3) Vibration, sinusoidal (IEC/EN 60255-21-1) Shock (IEC/EN 60255-21-2) Isolation data Rated impulse withstand voltage Uimp Pollution degree (IEC/EN 60664-1) Overvoltage category (IEC/EN 60664-1) Rated insulation voltage Ui Basisc insulation CM-ENS.1x CM-ENS.2x CM-ENS.31 on request 100 % see dimensional drawings see ordering details DIN rail (IEC/EN 60715), snap-on mounting without any tool any CM-ENS.x1: not necessary CM-ENS.x3: 10 mm if contact current > 2 A housing / terminals IP50 / IP20 UL 94 V-0 Screw connection technology finestrand with(out) 1 x 0.5-2.5 mm² (1 x 18-14 AWG) wire end ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 8 mm (0.32 in) 0.6 - 0.8 Nm (7.08 lb.in) Easy Connect Technology (push-in) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) - IEC/EN 60255-27, IEC/EN 60947-5-1 2014/35/EU 2014/30/EU 2011/65/EU operation -25...+60 °C storage -40...+85 °C 6 x 24 h cycle, 55 °C, 95 % RH 3K5 (no condensation, no ice formation) class 2 class 2 supply circuit / 4 kV measuring circuit supply circuit / 4 kV output circuits measuring circuit / 4 kV output circuits output circuit 1 / 4 kV output circuit 2 3 III supply circuit / 300 V measuring circuit supply circuit / 300 V output circuits measuring circuit / 300 V output circuits output circuit 1 / 300 V output circuit 2 supply circuit / 250 V AC / 300 V DC measuring circuit supply circuit / 250 V AC / 300 V DC output circuits measuring circuit / 250 V AC / 300 V DC output circuits output circuit 1 / 250 V AC / 300 V DC output circuit 2 ERC CATALOG MEASURING AND MONITORING REL AYS 235 -- Liquid level monitoring relays Technical data Type Protective separation (IEC/EN 61140, EN 50178) Pollution degree Overvoltage category Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge conducted disturbances, induced by radiofrequency fields voltage dips, short interruptions and voltage variations Interference emission high-frequency radiated high-frequency conducted CM-ENS.1x supply circuit / 250 V AC / 300 V DC measuring circuit supply circuit / 250 V AC / 300 V DC output circuits measuring circuit / 250 V AC / 300 V DC output circuits 3 III CM-ENS.2x CM-ENS.31 EN 61000-6-1, EN60255-26 IEC/EN 61000-4-2 level 3 (6 kV / 8 kV) IEC/EN 61000-4-3 level 3 (10 V/m) IEC/EN 61000-4-4 level 3, 2 KV / 5 kHz IEC/EN 61000-4-5 level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth IEC/EN 61000-4-6 level 3, 10 V IEC/EN 61000-4-11 class 3 IEC/EN 61000-6-3, IEC/EN 61000-6-4 IEC/CISPR 22, EN 55022 class B IEC/CISPR 22, EN 55022 class B 236 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Function diagrams 2CDC 252 003 F0015 2CDC 252 001 F0015 CM-ENS A1-A2/A2-A3 Liquid level max. min. 11-14 11-12 U: green LED R: yellow LED MIN/MAX: yellow LED Drain: CM-ENS.1x, CM-ENS.2x A1-A2 Liquid level max. min. A t 11-14/21-24 11-12/21-22 U/T: green LED R: yellow LED MIN/MAX: yellow LED B 11-14/21-24 11-12/21-22 U/T: green LED R: yellow LED MIN/MAX: yellow LED Drain: CM-ENS.31 t t CM-ENE MIN MIN C A1-A2 13-14 CM-ENE MAX MIN C A1-A2 13-14 A1-A2/A2-A3 max. min. Liquid level 11-14 11-12 U: green LED R: yellow LED MIN/MAX: yellow LED Fill: CM-ENS.2x 2CDC 252 004 F0015 A1-A2 max. min. Liquid level t A t 11-14/21-24 11-12/21-22 U/T: green LED R: yellow LED MIN/MAX: yellow LED t t 2CDC 252 002 F0015 B t 11-14/21-24 11-12/21-22 U/T: green LED R: yellow LED MIN/MAX: yellow LED t t Fill: CM-ENS.31 1SVC 110 000 F 0151 The liquid level relays CM-ENE MIN and CM-ENE MAX are used to monitor levels of conductive liquids, for example, in pump control systems for dry-running or overflow monitoring. The measuring principle is based on the occurring resistance change when moistening single-pole electrodes. The single-pole electrodes (see also section Accessories) are connected to the terminals C and MIN or MAX. If the supply voltage is applied to A1-A2 and the electrodes are wet, the output relay of the CM-ENE MIN is energized and the output relay of the CM-ENE MAX is de-energized. The output relay of the CM-ENE MIN de-energizes if the electrodes are no longer wet. The output relay of the CM-ENE MAX energizes if the electrodes are no longer wet. 1SVC 110 000 F 0152 ERC CATALOG MEASURING AND MONITORING REL AYS 237 -- Liquid level monitoring relays Technical diagrams -- Connection diagrams CM-ENS.11x, CM-ENS.21x A1 11 C MAX MIN C MAX MIN 11 CM-ENS.13x, CM-ENS.23x A1 11 A3 C MAX MIN C MAX MIN 11 CM-ENS.31x A1 1115 C MAX MIN C MAX MIN 11 21 2CDC 252 006 F0015 2CDC 252 005 F0015 2CDC 252 007 F0015 A1 A2 12 14 14 12 A2 A1A2 1112/14 C MAX MIN Control supply voltage 1 c/o (SPDT) contact Reference electrode Maximum level electrode Minimum level electrode A1 A3 A2 12 14 14 12 A2 A1A2 A3-A2 1112/14 C MAX MIN Control supply voltage 220-240 V AC Control supply voltage 110-130 V AC 1 c/o (SPDT) contact Reference electrode Maximum level electrode Minimum level electrode 12 14 22 24 A1 A3 A2 2428 2125 2226 1418 1216 A2 A1A2 11151216/1418 2125-2226/2428 C MAX MIN Control supply voltage 1 c/o (SPDT) contact 2nd c/o (SPDT) contact Reference electrode Maximum level electrode Minimum level electrode CM-ENE MIN CM-ENE MAX 1SVC 110 000 F 0153 1SVC 110 000 F 0154 A1-A2 C MIN 13-14 Rated control supply voltage Reference electrode Minimum level Output contact -open-circuit principle A1-A2 C MIN 13-14 Rated control supply voltage Reference electrode Maximum level Output contact -open-circuit principle 238 ERC CATALOG MEASURING AND MONITORING REL AYS -- Liquid level monitoring relays Technical diagrams CM-ENS.1x 1SVC 110 000 F0157 Liquid level control - drain CM-ENS.2x, CM-ENS.31x CM-ENS.2x, CM-ENS.31x 1SVC 110 000 F0162 1SVC 110 000 F0161 Liquid level control - fill - selected function " " (UP) Liquid level control - drain - selected function " " (Down) ERC CATALOG MEASURING AND MONITORING REL AYS 239 -- Liquid level monitoring relays Technical diagrams 22CCDDC 2C52215932F1029035 F0205 -- Load limit curves CM-S (22.5 mm), CM-E (22.5 mm) AC load (resistive) V 300 V 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F for inductive AC load 1.0 0.9 0.8 F 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 2C2DCC 2D52C19225F02210592 F0205 22CDCCD25C2 12945 F20210954 F0205 DC load (resistive) V 300 V 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 1 2 4 6 10 I A Contact lifetime Switching cycles 250 V resistive load Switching current [A] 22CCDCD2C52215482 F1024086F0206 -- Dimensional drawing Dimension in mm and inches 113.4 44.65" 105.9 41.69" 22.5 0.89" 85.6 33.70" 2CDC252010F0011 103.7 40.83" CM-xxS 1SVR730xxxxxx, 1SVR740xxxxxx 240 1SVC 110 000 F0478 2CDC 251 002 F0005 1SVR 450 056 F6000 ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS 241 -- Accessories Table of contents 242 Ordering details 244 Technical diagrams 245 Technical diagrams 242 ERC CATALOG MEASURING AND MONITORING REL AYS -- Accessories Ordering details 1SVR 450 056 F6000 1SVC 110 000 F0478 Bar electrode Suspension electrode 1SVR 450 056 F6000 1SVC 110 000 F0478 -- Ordering details Accessories Description For type Width in for devices Type mm Adapter for CM-S screw CM-S.S/P mounting CM-N CM-N.S/P Marker label CM-S, CM-N CM-S.S/P CM-N.S/P CM-S, CM-N 22.5 45 CM-S.S/P CM-N.S/P Sealable CM-S transparent CM-N cover CM-S.S/P CM-N.S/P 22.5 45 22.5 45 ADP.01 ADP.02 without DIP MAR.01 switches with DIP switches with DIP switches MAR.02 MAR.12 COV.01 COV.02 COV.11 COV.12 Order code 1SVR430029R0100 1SVR440029R0100 1SVR366017R0100 1SVR430043R0000 1SVR730006R0000 1SVR430005R0100 1SVR440005R0100 1SVR730005R0100 1SVR750005R0100 Bar electrodes Description Material Type no. Order code Compact support for 3 bar electrodes Distance plate for 3 bar electrodes - Counter nut for 1" thread Length: 300 mm Length: 600 mm Length: 1000 mm 1.4301 1.4301 1.4301 CM-KH-3 1SVR450056R6000 CM-AH-3 1SVR450056R7000 CM-GM-1 CM-SE-300 1SVR450056R8000 1SVR450056R0000 CM-SE-600 1SVR450056R0100 CM-SE-1000 1SVR450056R0200 Pkg Weight qty (1 pc) g (oz) 1 18.4 (0.65) 1 36.7 (1.30) 10 0.19 (0.007) 10 0.13 (0.005) 10 0.152 (0.335) 1 5.2 (0.18) 1 7.7 (0.27) 1 4.0 (0.129) 17 (0.247) Weight (1 pc) kg (lb) 0.06 (0.132) 0.06 (0.132) 0.06 (0.132) 0.08 (0.176) 0.08 (0.176) 0.08 (0.176) Suspension electrodes Description Connec- Material Type tion no. Order code CM-HE suspension electrode high-alloy steel, material no. 1.4104 (according to EN 10088-1) Screw 1.4104 CM-HE 1SVR402902R0000 CM-HC suspension electrode high-alloy steel, material no. 1.4104 (according to EN 10088-1) Crimp CM-HCT suspension electrode suitable Crimp for drink water high-alloy steel, material no. 1.4301 (according to EN 10088-1) 1.4104 1.4301 CM-HC 1SVR402902R1000 CM-HCT 1SVR402902R2000 Weight (1 pc) kg (lb) 0.074 (0.163) 0.09 (0.198) 0.09 (0.198) ERC CATALOG MEASURING AND MONITORING REL AYS 243 -- Accessories Ordering details 2CDC 251 002 F0005 2CDC 251 003 F0005 CM-CT CM-CT with mounted accessories CM-CT-A mounted on DIN rail 2CDC 251 159 F0b06 2CDC 251 002 F0005 2CDC 251 003 F0005 Plug-in current transformers CM-CT · Without primary conductor though with foot angle, insulating protective cap and bar fastening screws · Primary / rated current from 50 A to 600 A · Secondary current of 1 A or 5 A · Class 1 -- Ordering details Rated primary Secondary Burden class Type current current Order code 50 A 75 A 100 A 150 A 200 A 300 A 400 A 500 A 600 A 50 A 75 A 100 A 150 A 200 A 300 A 400 A 500 A 600 A 1 A 1 VA / 1 CM-CT 50/1 1SVR450116R1000 1.5 VA / 1 CM-CT 75/1 1SVR450116R1100 2.5 VA / 1 CM-CT 100/1 1SVR450116R1200 2.5 VA / 1 CM-CT 150/1 1SVR450116R1300 2.5 VA / 1 CM-CT 200/1 1SVR450116R1400 5 VA / 1 CM-CT 300/1 1SVR450117R1100 5 VA / 1 CM-CT 400/1 1SVR450117R1200 5 VA / 1 CM-CT 500/1 1SVR450117R1300 5 VA / 1 CM-CT 600/1 1SVR450117R1400 5 A 1 VA / 1 CM-CT 50/5 1SVR450116R5000 1.5 VA / 1 CM-CT 75/5 1SVR450116R5100 2.5 VA / 1 CM-CT 100/5 1SVR450116R5200 2.5 VA / 1 CM-CT 150/5 1SVR450116R5300 5 VA / 1 CM-CT 200/5 1SVR450116R5400 5 VA / 1 CM-CT 300/5 1SVR450117R5100 5 VA / 1 CM-CT 400/5 1SVR450117R5200 5 VA / 1 CM-CT 500/5 1SVR450117R5300 5 VA / 1 CM-CT 600/5 1SVR450117R5400 Weight (1 pc) g (oz) 0.31 (0.683) 0.31 (0.683) 0.276 (0.608) 0.32 (0.705) 0.222 (0.489) 0.29 (0.639) 0.27 (0.595) 0.29 (0.639) 0.24 (0.529) 0.3 (0.661) 0.31 (0.683) 0.31 (0.683) 0.28 (0.617) 0.29 (0.639) 0.252 (0.556) 0.26 (0.573) 0.208 (0.459) 0.21 (0.463) Accessories Description Type Snap-on fastener for DIN rail mounting of CM-CT CM-CT A Order code 1SVR450118R1000 Weight (1 pc) g (oz) 0.009 (0.02) 2CDC 251 159 F0b06 244 ERC CATALOG MEASURING AND MONITORING REL AYS -- Accessories Technical diagrams -- Operating principle / circuit diagram CM-CT K/P1 k/S1 L/P2 l/S2 load 2C2DCDCC22552200001F10F2002606 -- Dimensional drawings in mm and inches 22.5 0.89" 8 0.32" 4.8 0.19" 45.0 0.89" 9.3 0.37" 5.75 0.23" 68 2.68" 2CDC252010F0011 68 2.68" 2CDC252023F0011 Sealable cover COV.11 3A11 20 0.787" MAR.01 8 0.315" 2CDC 252 186 F0005 front to back 110.5 4.31" Sealable cover COV:12 front to back 111.8 4.40" ERC CATALOG MEASURING AND MONITORING REL AYS 245 -- Accessories Technical diagrams -- Dimensional drawings in mm and inches 61 2.36" 48 1.89" 35 1.38" 2CDC2C252D 153C F0b06252 153 F0b06 78,5 3.09" 75,5 2.97" 31 1.22" k l 26 CM-CT K-P1 a b c d e 40 1.57" 60 2.36" a 10,5 mm b 12,5 mm c 20,5 mm d 25,5 mm e 30,5 mm 0.41 inch 0.49 inch 0.81 inch 1.00 inch 1.20 inch a b c d 6,5 0.26" e 30 1.18" 47 1.85" 62 2.40" 11,5 .453" 4,5 .177" 2CDC 252 187 F0005 11,5 .453" 32,5 1.28" 45,0 1.77" 2CDC252001F0009 4,5 .177" 62,5 2.46" ADP.01 60 2.36" 10 .394" 22,5 .886" 2CDC 252 187 F0005 62,5 2.46" ADP.02 60 2.36" 246 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 247 -- Power supplies Table of contents 248 Overview 250 Selection table 253 Power supplies for industrial applications 255 CP-E range 275 CP-T range 289 CP-C.1 range 313 Power supplies for building applications 314 CP-D range 327 CP-B range buffer modules 339 Redundancy units 349 Electronic protection devices EPD24 248 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Primary switch mode power supplies Overview Modern power supply units are a vital component in energy management and automation technology. As your global partner in these areas, ABB pays the utmost attention to the resulting requirements. Innovation is the key to ABB's power supply product program. -- Power supplies for industrial applications CP-E range: economy range The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply units can be operated at an ambient temperature of up to +70 °C. The CP-E range 24 V devices over 18 W offer an output/contact for monitoring of the output voltage and remote diagnosis. Optimized for worldwide applications, the CP-E power supplies can be supplied within a wide range of AC or DC voltages. The output voltage is continuously adjustable, ensuring optimal adaptation to the application, e.g. compensating the voltage drop caused by a long line length. For decoupling of parallel connected power supplies below or equal to 56 V, redundancy modules are available in order to achieve true redundancy. CP-T range: three-phase range The CP-T range of three-phase power supply units perfectly complements ABB's existing power supply offering in terms of design and functionality, giving you more advanced options for your three-phase applications. Solid state output for function monitoring and remote diagnostics is available. The range is to be used in 340 - 575 V AC or 480 - 820 V DC supply systems. Its continuously adjustable output voltage ensures optimal adaptation to the application, e.g. compensating the voltage drop caused by a long line length. CP-C.1 range: high-performance range The CP-C.1 power supplies are ABB's high-performance and most advanced range. With excellent efficiency, high reliability and innovative functionality, the CP-C.1 range is ready to take on the most demanding industrial applications. These power supplies have a 150 % integrated power reserve and operate at an efficiency of up to 94 %. They are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals, the CP-C.1 power supplies are the preferred choice for professional DC applications. Giving the power to control. ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 249 -- Primary switch mode power supplies Overview -- Power supplies for industrial applications CP-B range: short time buffers ABB offers an innovative and completely maintenance- free product range for buffering the 24 V DC supply in case of interrupted mains on the primary side of the switch mode power supply. · Ultra cap based buffer modules for short time UPS systems · Rated input voltage 24 V DC · Rated currents 3 A, 10 A and 20 A · Expandable with CP-B EXT.2 module · LEDs for status indication · Higher than 90% efficiency · Signaling and status outputs · Buffering times at 100 % load current from 13 s to 38 s (depending on device) -- Power supplies for building applications CP-D range: distribution panel design The CP-D range of power supply units in MDRC design (modular DIN rail components) fits into all domestic installation and distribution panels. With their width of only 18 to 90 mm, the CP-D range switch mode power supplies are ideally suited for installation in distribution panels. The range is optimized for worldwide applications: The CP-D power supplies can be supplied with 90-264 V AC or 120-375 V DC. The continuously adjustable output voltage (CP-D > 10 W) ensures optimal adaption to the application, e.g. compensating the voltage drop caused by a long line length. An additional redundancy unit CP-RUD to establish true redundancy is available. For certifications and approvals, please refer to the download section on the product web pages. 250 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Primary switch mode power supplies Selection table - Single-phase Order number 1SVR427041R1000 1SVR427043R1200 1SVR427041R0000 1SVR427043R0100 1SVR427044R0200 1SVR427045R0400 1SVR427033R3000 1SVR427032R1000 1SVR427035R1000 1SVR427030R0000 1SVR427031R0000 1SVR427032R0000 1SVR427034R0000 1SVR427035R0000 1SVR427036R0000 1SVR427030R2000 1SVR427031R2000 1SVR427034R0000 1SVR427035R2000 1SVR360563R1001 1SVR360663R1001 1SVR360763R1001 1SVR360563R2001 1SVR360663R2001 1SVR360763R2001 1SVR361563R1001 1SVR361663R1001 1SVR361763R1001 Single-phase CP-D CP-E CP-C.1 Rated output voltage 5 V DC 12 V DC N N N NN 24 V DC NNNN NNNN NN NNNNNNNNN 48 V DC NN N N Rated output 0.42 A N current 0.625 A N 0.75 A N 0.83 A N 1.25 A N N 1.3 A N 2.1 A N 2.5 A N N N 3 A N 4.2 A N 5 A N N N N N 10 A N N N N N N 20 A N N N N Rated output power 10 W N N 15 W N 18 W N 25 W N 30 W N N N N 60 W N N N 100 W N 120 W N N N N N 240 W N N N N N 480 W N N N N N Rated input voltage 100-240 V AC N N N N N N N N NNN 115/230 V AC auto select N NN NN N NNNNNNNNN 115-230 V AC N N DC input voltage range 90-300 V DC 90-375 V DC N 120-375 V DC N N N N N N N NN N NN N NNNNNNNNN N 210-375 V DC N NN N Features Power reserve design NNNNNNNNN Adjustable output voltage N NNNNN N N N N N N NNN N NNNNNNNNNN Integrated input fuse N N N N N N N N N N N N N N N N N N N N N N N N N N N N Short-circuit stable N N N N N N N N N N N N N N N N N N N N N N N N N N N N Fold-forward behavior (U/I) N NNN NN N N N N NNN N NNNNNNNNNN Fold-back behavior (hiccup) N N N N Power factor correction pas pas pas act pas act act act act act act act act act act Signalling contact NNN NN NNNNNNNNN Extended temp. range N N N N N N NN N N N N NNN N N NNN Parallel connection NN 3 N N N 3 3 3NN 3 3 5 5 5 5 5 5 5 5 5 Serial connection N N N N N N N N 2 N N N 2 2 2 N N 2 2 2 2 2 2 2 2 2 2 2 Coated PCBA NNN pas = passive, act = active ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 251 -- Primary switch mode power supplies Selection table - Three-phase Order number 1SVR427054R0000 1SVR427055R0000 1SVR427056R0000 1SVR427057R0000 1SVR427054R2000 1SVR427055R2000 1SVR427056R2000 Rated output voltage Rated output current Rated output power Rated input voltage Three-phase CP-T 24 V DC N N N N 48 V DC NNN 5A N N 10 A N N 20 A N N 40 A N 120 W N 240 W N N 480 W N N 960 W N N 3 x 400-500 V AC NNNNNNN DC input voltage range 480-820 V DC NNNNNNN Features Adjustable output voltage N N N N N N N Integrated input fuse N N N N N N N Short-circuit stable N N N N N N N Fold forward behavior (U/I) N N N NN Fold back behavior (hiccup) N N N N N N N Extended temp. range N N N N N N N Signalling contact N N N N Parallel connection 222222 Serial connection 222222 252 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 253 -- Power supplies for industrial applications Table of contents 255 CP-E range 275 CP-T range 289 CP-C.1 range 254 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 255 -- CP-E range Table of contents 256 Benefits and advantages 258 Operating controls 259 Applications 260 Ordering details 261 Technical data 271 Technical diagrams 256 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Benefits and advantages ABB's CP-E range offers enhanced functionality and a simpler, more rational selection process. All power supply units can be operated at an ambient temperature of up to +70 °C (158 °F). Affordable range Products with exactly the functions you require. Designed for best possible price-performance ratio. Global availability The product can be used in any installations in the world. Giving you the confidence of worldwide sourcing no matter where you build, install or operate your equipment. Speed up your projects Data available for common planning software: Less engineering time required. ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 257 -- CP-E range Benefits and advantages Characteristics · Output voltages 5 V, 12 V, 24 V, 48 V DC · Adjustable output voltages · Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A / 5 A / 10 A / 20 A · Power range 15 W, 18 W, 30 W, 60 W, 120 W, 240 W, 480 W · High efficiency, up to 90 % · Low power dissipation and low heating · Free convection cooling (no forced cooling with ventilators) · Open-circuit, overload and short-circuit stable · Integrated input fuse · U/I characteristic curve on devices > 18 W (fold-forward behavior at overload no switch-off) · Redundancy units offering true redundancy · LED(s) for status indication · Signalling output/contact for output voltage OK - Transistor on 24 V devices > 18 W and < 120 W - Solid-state on 24 V devices 120 W · Various approvals and marks Main benefits Signalling output / contact The CP-E range 24 V devices > 18 W offer an output/contact for monitoring of the output voltage and remote diagnosis. Wide range input Optimized for worldwide applications: The CP-E power supplies can be supplied with a wide range of AC or DC voltages. Adjustable output voltage A continuously adjustable output voltage ensures optimal adaptation to the application, e.g. compensating the voltage drop caused by a long line length. Redundancy units For decoupling of parallelized power supply units 40 A. Thus, true redundancy can be achieved. 258 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Operating controls OUTPUT Adjust: Potentiometer adjustment of output voltage Indication of operational states: OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Single/parallel: Sliding switch adjustment of single or parallel operation OUTPUT L+, L+, L, L-: Terminals output 5 V / 12 V / 24 V / 48 V 13-14: Terminals signalling contact (or solid-state) Circuit diagram INPUT L, N, PE: terminals input 90-132 V AC, 180-265 V AC / 210-375 V DC 90-264 V AC / 120-375 V DC 85-264 V AC / 90-375 V DC ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 259 -- CP-E range Applications Tooling machines Packaging industry Food industry Textile industry Printing industry Electromobility 260 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Ordering details CP-E 5/0.75 CP-E 12/2.5 CP-E 48/5.0 CP-E 24/20.0 2CDC 271 013 F0006 2CDC 271 027 F0008 2CDC 271 028 F0008 2CDC 271 017 F0006 -- Description This range offers types with output voltages from 5 V DC to 48 V DC at output currents of 0.625 A to 20 A. With their high thermal efficiency of up to 90 %, these power supplies have very low power and heat dissipation and can be operated without forced cooling. The functionality has been enhanced while the number of different types has been considerably reduced. Of course, all power supplies of the CP-E range are approved in accordance with all relevant international standards. -- Ordering details - CP-E < 100 W Input voltage range Rated output Type voltage / current 90-264 V AC / 120-375 V DC 5 V DC / 3 A CP-E 5/3.0 85-264 V AC / 90-375 V DC 12 V DC / 2.5 A CP-E 12/2.5 90-132 V AC, 180-264 V AC / 210-375 V DC 90-264 V AC / 120-375 V DC 12 V DC / 10 A 24 V DC / 0.75 A CP-E 12/10.0 CP-E 24/0.75 85-264 V AC / 90-375 V DC 24 V DC / 1.25 A CP-E 24/1.25 85-264 V AC / 90-375 V DC 24 V DC / 2.5 A CP-E 24/2.5 Order code 1SVR427033R3000 1SVR427032R1000 1SVR427035R1000 1SVR427030R0000 1SVR427031R0000 1SVR427032R0000 Weight (1 pc.) kg (lb) 0.15 (0.33) 0.29 (0.64) 1.00 (2.20) 0.15 (0.33) 0.29 (0.64) 0.36 (0.79) -- Ordering details - CP-E M 120 W Input voltage range Rated output voltage / current Type 90-132 V AC, 180-264 V AC / 210-375 V DC 90-132 V AC, 180-264 V AC / 210-375 V DC 90-264 V AC / 120-375 V DC 24 V DC / 5 A 24 V DC / 10 A 24 V DC / 20 A CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0 85-264 V AC / 90-375 V DC 48 V DC / 0.625 A CP-E 48/0.62 85-264 V AC / 90-375 V DC 48 V DC / 1.25 A CP-E 48/1.25 90-132 V AC, 180-264 V AC / 210-375 V DC 90-264 V AC / 120-375 V DC 48 V DC / 5 A 48 V DC / 10 A CP-E 48/5.0 CP-E 48/10.0 Order code 1SVR427034R0000 1SVR427035R0000 1SVR427036R0000 1SVR427030R2000 1SVR427031R2000 1SVR427034R2000 1SVR427035R2000 Weight (1 pc.) kg (lb) 1.00 (2.20) 1.36 (3.01) 1.90 (4.18) 0.29 (0.64) 0.36 (0.79) 1.36 (3.01) 1.90 (4.19) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 261 -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Input circuit Rated input voltage Uin CP-E 5/3.0 L, N 100-240 V AC CP-E 12/2.5 CP-E 12/10.0 115 / 230 V AC auto select Input voltage range 90-264 V AC / 120-375 V DC 85-264 V AC / 90-375 V DC 90-132 V AC, 180-264 V AC / 210-375 V DC Frequency range AC Typical input current Typical power consumption Inrush current Discharge current Power failure buffering time Internal input fuse 47-63 Hz at 115 V AC 335 mA 560 mA at 230 V AC 210 mA 330 mA 19.8 W 35.9 W at 115 V AC 15 A 20 A at 230 V AC 30 A 40 A input / output 0.25 mA input / PE 3.5 mA at 115 V AC min. 20 ms min. 20 ms at 230 V AC min. 75 ms min. 30 ms 2 A slow-acting / 250 V AC 2.2 A 0.83 A 143 W 24 A 48 A min. 25 ms min. 30 ms 3.15 A slow-acting / 250 V AC Power factor correction (PFC) Indication of operational states Output voltage no green LED OK: V: output voltage OK yes, passive, 0.7 OUTPUT OK: V: output voltage OK OUTPUT OK: V: output voltage OK red LED LOW: V: - output voltage too low OUTPUT LOW: V: output voltage too low Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current Maximum deviation with L+,L5 V DC 0...+1 % 4.5-5.75 V DC 15 W Ta m 60 °C 3.0 A 60 °C < Ta m 70 °C 2.5 %/°C load change statical ±2 % L+, L+, L-, L12 V DC 12-14 V DC 30 W 2.5 A 2.5 %/°C ±0.5 % 11.4-14.5 V DC 120 W 10 A ±1 % (single mode) ±5 % (parallel mode) change of output voltage ±1 % within the input voltage range ±0.5 % ±0.5 % Recovery time TR Starting time after applying the supply voltage Rise time Fall time Residual ripple and switching peaks Parallel connection Series connection < 2 ms at Ir max. 1 s with 3500 µF - max. 2 s with 7000 µF max. 1.5 s - at rated load max. 150 ms with 3500 µF - max. 500 ms with 7000 µF max. 500 ms - max. 150 ms BW = 20 MHz 50 mV yes, to enable redundancy yes, to increase voltage max. 1.5 s max. 500 ms configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir yes, to increase voltage, max. 2 devices Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Overload protection No-load protection Starting of capacitive loads 1 s - max. 7.5 V DC 1 s - max.18 V DC max. 18 V DC hiccup-mode U/I characteristic curve continuous short-circuit proof Hiccup-mode continuation with output power limiting output power limiting continuous no-load stability 7000 µF 3500 µF 7000 µF 262 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 5/3.0 CP-E 12/2.5 CP-E 12/10.0 General data Power loss typ. 5 W typ. 5.6 W typ. 24 W Efficiency typ. 75 % typ. 84 % typ. 84 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing plastic metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Connecting capacity fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) fine-strand without wire end 0.2-2.5 mm2 (24-14 AWG) ferrule 0.2-6 mm² (24-10 AWG) Stripping length Tightening torque rigid 6 mm (0.24 in) input / output 0.6 Nm (5 lb.in) 8 mm (0.31 in) 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in) Environmental data Ambient temperature range operation -20...+70 °C -40...+70 °C -35...+70 °C rated load -20...+60 °C -40...+60 °C -35...+60 °C storage -20...+85 °C -40...+85 °C -40...+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 RH, % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category II Standards / Directives Standards IEC/EN 60950-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields IEC/EN 61000-4-4 level 4 (4 kV / 2,5 kHz) level 4 (4 kV / 5 kHz) IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) IEC/EN 61000-4-6 level 3 (10 V) power frequency magnetic fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class D class A class D ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 263 -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Input circuit Rated input voltage Uin Input voltage range CP-E 24/0.75 L, N 100-240 V AC 90-264 V AC / 120-375 V DC CP-E 24/1.25 85-264 V AC / 90-375 V DC CP-E 24/2.5 Frequency range AC Typical input current Typical power consumption Inrush current Discharge current Power failure buffering time Internal input fuse Power factor correction (PFC) Indication of operational states Output voltage 47-63 Hz at 115 V AC 335 mA 560 mA at 230 V AC 210 mA 330 mA 22.8 W 36.7 W at 115 V AC 15 A 20 A (max. 3 ms) at 230 V AC 30 A 40 A (max. 3 ms) input / output 0.25 mA input / PE 3.5 mA at 115 V AC min. 20 ms min. 20 ms at 230 V AC min. 75 ms min. 30 ms 2 A slow-acting / 250 V AC no 1060 mA 590 mA 69.2 W 30 A 60 A green LED OK: V: output voltage OK OUTPUT OK: V: output voltage OK red LED LOW: V: - - output voltage too low Output circuit L+,L- L+, L+, L-, L- Rated output voltage 24 V DC Tolerance of the output voltage 0 ... +1 % Adjustment range of the output voltage 21.6-28.8 V DC 24-28 V DC Rated output power 18 W 30 W Rated output current Ir Derating of the output current Signalling output for output voltage OK Ta m 60 °C 0.75 A 60 °C < Ta m 70 °C 2.5 %/°C DC OK - 1.25 A transistor Maximum deviation with load change statical ±2 % ±0.5 % change of output voltage ±1 % within the input voltage range ±0.5 % Recovery time TA Starting time after applying the supply voltage < 2 ms at Ir max. 1 s with 3500 µF - max. 2 s with 7000 µF max. 1.5 s - Rise time at rated load max. 150 ms with 3500 µF - max. 500 ms with 7000 µF max. 500 ms - Fall time max. 150 ms Residual ripple and switching peaks BW = 20 MHz 50 mV Parallel connection yes, to enable redundancy 60 W 2.5 A max. 1.5 s max. 500 ms Series connection yes, to increase voltage Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Overload protection No-load protection Starting of capacitive loads 1 s - max. 35 V DC hiccup-mode U/I characteristic curve continuous short-circuit proof hiccup-mode continuation with output power limiting output power limiting continuous no-load stability 7000 µF 3500 µF 7000 µF 264 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 24/0.75 CP-E 24/1.25 CP-E 24/2.5 General data Power loss typ. 4.45 W typ. 5.5 W typ. 8.8 W Efficiency typ. 77 % typ. 86 % typ. 89 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Connecting capacity fine-strand with wire end ferrule fine-strand without 0.2-2.5 mm2 (24-14 AWG) wire end ferrule rigid Stripping length 6 mm (0.24 in) Tightening torque input / output 0.6 Nm (5 lb.in) Environmental data Ambient temperature range operation -20...+70 °C -40...+70 °C rated load -20...+60 °C -40...+60 °C storage -20...+85 °C -40...+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category II Standards / Directives Standards IEC/EN 60950-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 level 4 (4 kV / 2.5 kHz) level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) conducted disturbances, induced by radiofrequency fields IEC/EN 61000-4-6 level 3 (10 V) power frequency magnetic fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class D class A ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 265 -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Input circuit Rated input voltage Uin Input voltage range Frequency range AC Typical input current Typical power consumption Inrush current Discharge current Power failure buffering time Internal input fuse CP-E 24/5.0 CP-E 24/10.0 L, N 115 / 230 V AC auto select 90-132 V AC, 180-264 V AC / 210-375 V DC 90-132 V AC, 180-264 V AC / 210-375 V DC 47-63 Hz at 115 V AC 2.2 A 4.0 A at 230 V AC 0.83 A 1.55 A 140 W 270 W at 115 V AC 24 A (max. 5 ms) 30 A (max. 5 ms) at 230 V AC 48 A (max. 5 ms) 60 A (max. 5 ms) input / output 0.25 mA input / PE 3.5 mA at 115 V AC min. 25 ms at 230 V AC min. 30 ms 3.15 A slow-acting / 250 V AC 6.3 A slow-acting / 250 V AC CP-E 24/20.0 115-230 V AC 90-264 V AC, 120-375 V DC 4.9 A 2.5 A 539 W 25 A (max. 5 ms) 50 A (max. 5 ms) 10 A slow-acting / 250 V AC Power factor correction (PFC) yes, passive, 0.7 yes, passive, 0.75 yes, active 115 V AC: 0.99 230 V AC: 0.97 Indication of operational states Output voltage Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current Signalling contact for output voltage OK Minimum fuse rating to achieve short-circuit protection green LED OUTPUT OK: V: output voltage OK red LED OUTPUT LOW: V: output voltage too low L+, L+, L-, L- 24 V DC 0...+1 % 22.5-28.5 V DC 120 W 240 W Ta m 60 °C 5 A 10 A Ta m 55 °C - - 60 °C < Ta m 70 °C 2.5 %/°C 55 °C < Ta m 70 °C - - 13-14 solid-state (max. 60 V DC, 0.3 A) 13-14 M 60 V DC, m 0.3 A fast-acting 480 W 20 A 2.5 %/°C Maximum deviation with load change statical ±1 % (single mode), ±5 % (parallel mode) change of output voltage ±0.5 % within the input voltage range Recovery time TR Starting time after applying the supply voltage Rise time Fall time Residual ripple and switching peaks Parallel connection Series connection Resistance to reverse feed < 2 ms at Ir max. 1 s 2.5 s (at -40 °C / 90 V AC starting time >2.5 s has to be expected) max. 1 s with 3500 µF max. 1.5 s - - with 7000 µF - 2.5 s max. 1.5 s at rated load max. 150 ms with 3500 µF max. 500 ms - - with 7000 µF - max. 500 ms max. 150 ms BW = 20 MHz 50 mV 100 mV configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir yes, to increase voltage, max. 2 devices max. 35 V DC 266 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0 Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit proof Short-circuit behavior continuation with output power limiting Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 3500 µF 7000 µF General data Power loss typ. 20 W typ. 35 W typ. 63 W Efficiency typ. 86 % typ. 89 % typ. 89 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Connecting capacity fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG) rigid Stripping length 8 mm (0.31 in) Tightening torque input / output 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in) Environmental data Ambient temperature range operation -35...+70 °C -40...+70 °C rated load -35...+60 °C -40...+60 °C -40...+55 °C storage -40...+85 °C -40...+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC signalling contact / PE 0.5 kV DC Pollution degree 2 Overvoltage category II Standards / Directives Standards IEC/EN 60950-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 267 -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0 IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields power frequency magnetic fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-4 level 4 (4 kV / 5 kHz) level 4 (4 kV / 2.5 kHz) IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) IEC/EN 61000-4-6 level 3 (10 V) IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-3 class B class B class D 268 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 48/0.62 CP-E 48/1.25 Input circuit L, N Rated input voltage Uin 100-240 V AC CP-E 48/5.0 115 / 230 V AC auto select CP-E 48/10.0 115-230 V AC Input voltage range 85-264 V AC / 90-375 V DC 90-132 V AC, 180-264 V AC / 210-375 V DC 90-264 V AC, 120-375 V DC Frequency range AC Typical input current Typical power consumption Inrush current Discharge current Power failure buffering time Internal input fuse 47-63 Hz at 115 V AC 560 mA 1060 mA at 230 V AC 330 mA 590 mA 35.7 W 69.0 W at 115 V AC 20 A 30 A at 230 V AC 40 A 60 A input / output 0.25 mA input / PE 3.5 mA at 115 V AC min. 20 ms at 230 V AC min. 30 ms 2 A slow-acting / 250 V AC 4.0 A 1.55 A 267 W 30 A (max. 5 ms) 60 A (max. 5 ms) 4.9 A 2.5 A 528 W 25 A (max. 5 ms) 50 A (max. 5 ms) min. 25 ms min. 25 ms 6.3 A slow-acting / 10 A slow-acting / 250 V AC 250 V AC Power factor correction (PFC) no yes, passive, 0.7 yes, active 115 V AC: 0.99 230 V AC: 0.97 Indication of operational states Output voltage green LED OUTPUT OK: V: output voltage OK red LED - - OUTPUT LOW: V: output voltage too low Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current Signalling output for output voltage OK Maximum deviation with L+, L+, L-, L48 V DC 0...+1 % 48-55 V DC 30 W Ta m 60 °C 0.625 A Ta m 55 °C 60 °C < Ta m 70 °C 2.5 %/°C 55 °C < Ta m 70 °C DC OK load change statical ±0.5 % 60 W 1.25 A - - 47-56 V DC 240 W 480 W 5 A - - 10 A - - 2.5 %/°C - - ±1 % (single mode) ±5 % (parallel mode) change of output voltage ±0.5 % within the input voltage range ±0.5 % Recovery time TR Starting time after applying the supply voltage Rise time Fall time Residual ripple and switching peaks Parallel connection Series connection < 2 ms at Ir max. 1 s with 3500 µF max. 2 s - with 7000 µF - max. 1.5 s at rated load max. 150 ms with 3500 µF max. 500 ms - with 7000 µF - max. 500 ms max. 150 ms BW = 20 MHz 50 mV yes, to enable redundancy yes, to increase voltage - - max. 1.5 s - - max. 500 ms 100 mV configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir yes, to increase voltage, max. 2 devices Resistance to reverse feed 1 s - max. 63 V DC ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 269 -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 48/0.62 CP-E 48/1.25 CP-E 48/5.0 CP-E 48/10.0 Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output U/I characteristic curve Short-circuit protection continuous short-circuit proof Short-circuit behavior continuation with output power limiting Overload protection output power limiting No-load protection continuous no-load stability Starting of capacitive loads 3500 µF 7000 µF unlimited 7000 µF General data Power loss typ. 4.9 W typ. 7.8 W typ. 32 W typ. 60 W Efficiency typ. 86 % typ. 89 % typ. 90 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing plastic metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP/20 / IP20 Protection class I Electrical connection - input circuit / output circuit Connecting capacity fine-strand with 0.2-2.5 mm² (24-14 AWG) wire end ferrule 0.2-4 mm² (24-11 AWG) fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG) rigid Stripping length 6 mm (0.24 in) 8 mm (0.31 in) Tightening torque input / output 0.6 Nm (5 lb.in) 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in) Environmental data Ambient temperature range operation -40...+70 °C rated load -40...+60 °C -40...+55 °C storage -40...+85 °C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % RH, without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis Shock (half-sine) (IEC/EN 60068-2-27) 15 G, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Overvoltage category II Standards / Directives Standards EN 61204-3 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) 270 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-E 48/0.62 CP-E 48/1.25 CP-E 48/5.0 CP-E 48/10.0 Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 level 4 (4 kV / 5 kHz) level 4 (4 kV / 2.5 kHz) surge IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) conducted disturbances, induced by radiofrequency fields IEC/EN 61000-4-6 level 3 (10 V/m) power frequency magnetic fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-3 class B class B class A class D ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 271 -- CP-E range Technical diagrams 2C2DCC 2D72C020762F00b0076 F0b07 22CDCCD2C72207027 F000b708F0b08 -- Output curve at Ta = 25 °C Uout [V] 15 13 11 9 7 5 3 1 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Iout [A] CP-E 12/2.5 Uout [V] 2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Iout [A] CP-E 24/2.5 Uout [V] 28 24 20 16 12 8 4 4 8 12 16 20 24 28 32 Iout [A] CP-E 24/20.0 Uout [V] 56 48 40 32 24 16 8 1 2345678 Iout [A] CP-E 48/5.0 22CDCCD2C72207029 F000b908F0b08 22CDCCD2C72207028 F000b808F0b08 22CDCCD27C2200772F00b0077 F0b07 2CDC 272 008 F0b07 2CDC 272 008 F0b07 Uout [V] 14 12 10 8 6 4 2 2 4 6 8 10 12 14 16 Iout [A] CP-E 12/10.0 Uout [V] 28 24 20 16 12 8 4 1 2345678 Iout [A] CP-E 24/5.0 Uout [V] 70 60 50 40 30 20 10 0.6650.705 0.745 0.7850.8250.8650.9050.9450.9851.025 Iout [A] CP-E 48/0.62 Uout [V] 56 48 40 32 24 16 8 2 4 6 8 10 12 14 16 Iout [A] CP-E 48/10.0 22CCDCD2C72207120 F001b008F0b08 22CDCCD27C2 020792F00b0079 F0b07 22CDCCD27C2207062 F000b068F0b08 22CDCCD27C2207052 F000b058F0b07 Uout [V] 1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15 Iout [A] CP-E 24/1.25 Uout [V] 28 24 20 16 12 8 4 2 4 6 8 10 12 14 16 Iout [A] CP-E 24/10.0 Uout [V] 70 60 50 40 30 20 10 1.33 1.41 1.49 1.57 1.65 1.73 1.81 1.89 1.97 2.05 Iout [A] CP-E 48/1.25 22CDCCD27C2201702F00b1070 F0b07 272 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-E range Technical diagrams 2CDC 272 018 F0211 -- Temperature behavior at Ta = 25 °C Pout [%] 100 90 80 70 60 50 40 30 20 10 -35 CP-E 12/10.0, CP-E 24/5.0 60 70 Ta [°C] Pout [%] 100 90 80 70 60 50 40 30 20 10 -20 CP-E 5/3.0, CP-E 24/0.75 60 70 Ta [°C] 2CDC 272 016 F0211 2CDC 272 015 F0211 Pout [%] 100 90 80 70 60 50 40 30 20 10 -40 CP-E 24/20.0, CP-E 48/10.0 55 70 Ta [°C] Pout [%] 100 90 80 70 60 50 40 30 20 10 -40 60 70 Ta [°C] CP-E 12/2.5, CP-E 24/1.25, CP-E 48/0.62, CP-E 24/2.5, CP-E 48/1.25, CP-E 24/10.0, CP-E 48/5.0 2CDC 272 017 F0211 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 273 -- CP-E range Technical diagrams 22CCDDCC27227201071F70F2007207 -- Wiring instructions Relay RL > 700 DC OK LCP-E 24/1.25, CP-E 24/2.5 5 V Signal DC OK L- 2.2 k 0.5 W 5.1 V 0.3 W -- Dimensional drawings Dimensions in mm, inches 114 4.49" 22.5 0.89" 40.5 1.59" 90 3.54" 90 3.54" 2CDC 272 021 F0011 123.6 [4.87"] 116.6 [4.59"] CP-E 5/3.0, CP-E 24/0.75 CP-E 12/2.5, CP-E 24/1.25, CP-E 24/2.5, CP-E 48/0.62, CP-E 48/1.25 63.2 [2.49"] 83.0 [3.27"] 175.0 [6.89"] 123.6 [4.87"] 123.6 [4.87"] 123.6 [4.87"] 2CD2CCD2C72272010133FF00b0808 CP-E 12/10.0, CP-E 24/5.0 CP-E 24/10.0, CP-E 48/5.0 CP-E 24/20.0, CP-E 48/10.0 2 74 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 275 -- CP-T range Table of contents 276 Benefits and advantages 278 Operating controls 279 Applications 280 Ordering details 281 Technical data 285 Technical diagrams 276 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-T range Benefits and advantages ABB's CP-T range of three-phase power supply units perfectly complements our existing power supply offering in terms of design and functionality, giving you more advanced options for your three-phase applications. Affordable range Products with exactly the functions you require. Designed for best price-performance ratio. Global availability The product can be used in any installation in the world. Giving you the confidence of world-wide sourcing no matter where you build, install or operate your equipment. Speed up your projects Data available for common planning software: Less engineering time required ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 277 -- CP-T range Benefits and advantages Characteristics · Rated output voltages 24 V, 48 V DC · Output voltage adjustable via front-facing rotary potentiometer "OUTPUT Adjust" · Rated output currents 5 A, 10 A, 20 A, 40 A · Rated output powers 120 W, 240 W, 480 W, 960 W · Three-phase operation (see derating note) · Two-phase operation (25 % derating possible, see derating note) · Supply range 3 x 400500 V AC (3 x 340-575 V AC, 480-820 V DC) · Typical efficiency of 93 % · Low power dissipation and low heating · Free convection cooling (no forced cooling with ventilators) · Ambient temperature range during operation -40...+70 °C 1) · Open-circuit, overload and short-circuit stable · Integrated input fuse · Redundancy unit CP-C.1-A-RU (-C) offering true redundancy, available as accessory · LEDs for status indication · Signalling contact "13-14" (solid-state) for output voltage OK on 24 V devices · Various approvals and marks 1) 480 W variants: -30...+70°C Main benefits Signalling output Some devices of the CP-T series offer a solid-state output for function monitoring and remote diagnostics. Wide input range Optimized for worldwide applications: The CP-T power supplies can be used in 340 - 575 V AC or 480 - 820 V DC supply systems. Adjustable output voltage The CP-T range features a continuously adjustable output voltage. Thus, they can be optimally adapted to the applications, e.g. compensating the voltage drop caused by a long line length. 278 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-T range Operating controls Indication of operational states · OUTPUT OK: green LED green LED output voltage OK · OUTPUT LOW: red LED output voltage too low Circuit diagram INPUT L1, L2, L3, PE: Terminals - input 340-575 V AC / 480-820 V DC OUTPUT L+, L+, L, L-: Terminals output 24 V DC, 48 V DC OUTPUT Adjust: Potentiometer adjustment of output voltage 22.5...28.5V DC Single/parallel: Sliding switch adjustment of single or parallel operation 13-14: Terminals - signalling contact A solid-state output indicates the error-free operation of the output voltage ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 279 -- CP-T range Applications Tunnel drilling machines Floor conveyors Quality power management systems 280 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-T range Ordering details CP-T 24/5.0 CP-T 24/10.0, CP-T 48/5.0 CP-T 24/20.0, CP-T 48/10.0 2CDC 271 043 S0009 2CDC 271 045 S0009 2CDC 271 047 S0009 Description In terms of design and functionality, the CP-T range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a three-phase voltage as well as with two-phase mains. Here, ABB offers power supply units with 24 V DC and 48 V DC outputs with 5 A, 10 A, 20 A and 40 A and efficiency of up to 93 %. As in the case of all products, they are designed for an ambient temperature of up to 70 °C. All products can be supplied within an AC supply voltage range between 340 to 575 V AC and a DC supply voltage range between 480 to 820 V DC. -- Ordering details Input voltage range 340-575 V AC / 480-820 V DC Rated output voltage / current Type 24 V DC / 5 A CP-T 24/5.0 340-575 V AC / 480-820 V DC 24 V DC / 10 A CP-T 24/10.0 340-575 V AC / 480-820 V DC 24 V DC / 20 A CP-T 24/20.0 340-575 V AC / 480-820 V DC 24 V DC / 40 A CP-T 24/40.0 340-575 V AC / 480-820 V DC 48 V DC / 5 A CP-T 48/5.0 340-575 V AC / 480-820 V DC 48 V DC / 10 A CP-T 48/10.0 340-575 V AC / 480-820 V DC 48 V DC / 20 A CP-T 48/20.0 Order code 1SVR427054R0000 1SVR427055R0000 1SVR427056R0000 1SVR427057R0000 1SVR427054R2000 1SVR427055R2000 1SVR427056R2000 Weight (1 pc.) kg (lb) 0.80 (1.77) 1.05 (2.31) 1.75 (3.86) 3.20 (7.05) 1.05 (2.31) 1.75 (3.86) 3.40 (7.50) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 281 -- CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 24/5.0 CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0 Input circuit L1, L2, L3 Rated input voltage Uin Input voltage range 3 x 400-500 V AC 340-575 V AC 480-820 V DC Frequency range AC 47-63 Hz Typical input current 0.36 A 0.65 A 1.1 A 1.72 A Typical power consumption 135 W 270 W 538 W 1058 W Inrush current typ. 10 A 20 A 30 A Power failure buffering time min. 20 ms min. 15 ms Internal input fuse per phase 2 A / 600 V AC T 3.15 A / 500 V AC T 5 A / 500 V AC Recommended backup fuse 3 pole miniature circuit breaker ABB Type S203 Power factor correction (PFC) yes, passive Discharge current towards PE < 3.5 mA input / output < 0.25 mA Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK when the output voltage > 75 % of the rated output voltage OUTPUT LOW: red LED output voltage too low when the output voltage < 70 % of the rated output voltage Output circuit L+, L+, L-, L- Rated output voltage 24 V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 22.5-28.5 V DC Rated output power 120 W 240 W 480 W 960 W Rated output current Ir Derating of the output current Signalling contact for output voltage OK Ta 60 °C 5 A 10 A 60 °C < Ta 70 °C 2.5 %/°C 13-14 solid-state (max. 60 V DC, 0.3 A) Threshold 17.6-19.4 V 20 A 40 A 3.5 %/°C Insulation voltage 500 V DC Mininum fuse rating to achieve short-circuit protection 13-14 M 60 V DC, m 0.3 A fast-acting Maximum deviation with load change statical ±1 % ±1 % (single mode) - ±5 % (parallel mode) change of output voltage ± 0.5 % within the input voltage range Recovery time TA Starting time after applying the supply voltage Rise time Fall time Residual ripple and switching peaks Parallel connection BW = 20 MHz at nominal load < 2 ms at Ir max. 1 s with 3500 µF max. 1.5 s at nominal load max. 150 ms with 3500 µF max. 500 ms max. 150 ms 100 mV not supported configurable, to increase power, up to 2 devices, min. 0.1 Ir - max 0.9 Ir 80 mV to increase power, up to 2 devices, min. 0.1 Ir - max. 0.9 Ir,use active current balancing Series connection Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output not supported approx. 35 V yes, to increase voltage, max. 2 devices combined U/I characteristic curve U/I- or hiccup- hiccup / fold and hiccup mode mode adjustable back behavior Short-circuit protection Short-circuit behavior Overload protection No-load protection Overtemperature protection Starting of capacitive loads continuous short-circuit proof current limiting hiccup mode continuous no-load stability yes, automatic recovery after temperature went down 3500 µF 7000 µF 7000 µF 7000 µF 282 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 24/5.0 CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0 General data Efficiency typ. 89 % typ. 90 % typ. 92 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit / signalling circuit Connecting capacity fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) fine-strand without wire end 0.2-6 mm² (24-10 AWG) ferrule Stripping length Tightening torque rigid 0.2-6 mm² (24-10 AWG) 8 mm (0.31 in) input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in) Environmental data Ambient temperature range operation -40...+70 °C -30...+70 °C rated load -40...+60 °C -30...+60 °C storage -40...+85 °C Altitude during operation IEC/EN 60068-2-13 max. 5000 m Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2G, each along X, Y, Z axes 60 min / cycle Shock (half-sine) (IEC/EN 60068-2-27) 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC signalling output / PE 0.5 kV DC Pollution degree 2 Standards / Directives Standards IEC/EN 60950-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) -40...+70 °C -40...+60 °C electrical fast transient/burst IEC/EN 61000-4-4 level 4 level 4 (4 kV / 5 kHz) (4 kV / 2.5 kHz) surge conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) IEC/EN 61000-4-6 level 3 (10 V) power frequency magnetic fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms, interruptions: >95 % 250 ms Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class A ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 283 -- CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 48/5.0 CP-T 48/10.0 CP-T 48/20.0 Input circuit L1, L2, L3 Rated input voltage Uin Input voltage range 3 x 400-500 V AC 340-575 V AC 480-820 V DC Frequency range AC 47-63 Hz Typical input current 0.65 A 1.1 A 1.72 A Typical power consumption 264 W 535 W 1050 W Inrush current typ. 20 A 30 A Power failure buffering time min. 20 ms min. 15 ms Internal input fuse per phase 2 A / 600 V AC T 3.15 A / 500 V AC T 5 A / 500 V AC Power factor correction (PFC) yes, passive Discharge current towards PE < 3.5 mA input / output < 0.25 mA Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK when the output voltage > 75 % of the rated output voltage OUTPUT LOW: red LED output voltage too low when the output voltage < 70 % of the rated output voltage Output circuit L+, L+, L-, L- Rated output voltage 48 V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 47-56 V DC Rated output power 240 W 480 W 960 W Rated output current Ir Derating of the output current Maximum deviation with Ta 60 °C 5 A 60 °C < Ta 70 °C 2.5 %/°C load change statical ±1 % (single mode) 10 A 20 A 3.5 %/°C ± 5 % (parallel mode) change of output voltage within the ±0.5 % input voltage range Recovery time TA Starting time after applying the supply voltage Rise time Fall time Residual ripple and switching peaks Parallel connection at rated load < 2 ms at Ir max. 1 s with 7000 µF max. 1.5 s at rated load max. 150 ms with 7000 µF max. 500 ms max. 150 ms BW = 20 MHz 100 mV configurable, to increase power, up to 2 devices, min. 0.1 Ir - max 0.9 Ir 80 mV to increase power, up to 2 devices, min. 0.1 Ir - max. 0.9 Ir, use active current balancing Series connection Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output yes, to increase voltage, max. 2 devices approx. 35 V approx. 63 V approx. 63 V combined U/I and hiccup mode U/I or hiccup mode, configurable hiccup mode / fold back behavior Short-circuit protection Short-circuit behavior Overload protection No-load protection Over temperature protection Starting of capacitive loads continuous short-circuit proof current limiting hiccup mode continuous no-load stability yes, automatic recovery after temperature went down 7000 µF 284 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-T range Technical data Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated Type CP-T 48/5.0 CP-T 48/10.0 CP-T 48/20.0 General data Efficiency typ. 91 % typ. 93 % Duty cycle 100% Dimensions see "Dimensional drawings" Material of housing Metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Connecting capacity fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) 0.2-4 mm² (24-11 AWG) / 0.5-10 mm² (20-8 AWG) fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG) rigid Stripping length 8 mm (0.31 in) Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in) Environmental data Ambient temperature range operation -40...+70 °C -30...+70 °C -40...+70 °C rated load -40...+60 °C -30...+60 °C -40...+60 °C storage -40...+85 °C -40...+85 °C -40...+85 °C Altitude during operation IEC/EN 60068-2-13 max. 5000 m Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) 10-500 Hz, 2G, each along X, Y, Z axes 6 min / cycle Shock (half-sine) (IEC/EN 60068-2-27) 15G, 11 ms, 3 axes, 6 Faces, 3 times for each face Isolation data Rated insulation voltage Ui input circuit / output circuit 3 kV AC input / PE 1.5 kV AC output / PE 0.5 kV AC; 0.71 kV DC Pollution degree 2 Standards / Directives Standards IEC/EN 60950-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 level 4 (4 kV / 5 kHz) surge IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3 (10 V) power frequency magnetic fields voltage dips, short interruptions and voltage variations IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms interruptions: >95 % 250 ms Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class A ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 285 -- CP-T range Technical diagrams 2CDC 272 034 F0x09 2CDC 272 037 F0x09 -- Output curves at Ta = 25 °C Uout [V] 28 @ 3 x 400V supply 24 @ 3 x 500V supply 20 16 12 8 4 Hiccup mode 1 2 3 4 5 6 7 8 Iout[A] CP-T 24/5.0 Uout [V] 28 @ 3 x 400V supply 24 @ 3 x 500V supply 20 16 12 8 4 Hiccup mode 4 8 12 16 20 24 28 32 Iout[A] CP-T 24/20.0 Hiccup mode Uout [V] 56 @ 3 x 400V supply 48 @ 3 x 500V supply 40 32 24 16 8 2 4 6 8 10 12 14 16 Iout[A] CP-T 48/10.0 U/I curve 2CDC 272 038 F0x09 2CDC 272 035 F0x09 2CDC 272 032 F0x09 Uout [V] 28 @ 3 x 400V supply 24 @ 3 x 500V supply 20 16 12 8 4 Hiccup mode 2 4 6 8 10 12 14 16 Iout[A] CP-T 24/10.0 Uout in V 28 24 20 16 12 8 4 @ 3 x 400 V supply U/I Hiccup mode after 2-5 s overload 8 16 24 32 40 48 56 64 72 80 Ioutin A CP-T 24/40.0 Uout [V] 56 @ 3 x 400V supply 48 @ 3 x 500V supply 40 32 24 16 8 Hiccup mode 2 4 6 8 10 12 14 16 Iout[A] CP-T 48/10.0 Hiccup mode 2CDC 272 039 F0x09 2CDC 272 027 F0211 2CDC 272 033 F0x09 Uout [V] 28 @ 3 x 400V supply 24 @ 3 x 500V supply 20 16 12 8 4 4 8 12 16 20 24 28 32 Iout[A] CP-T 24/20.0 U/I curve Uout [V] 56 @ 3 x 400V supply 48 @ 3 x 500V supply 40 32 24 16 8 Hiccup mode 1 2 3 4 5 6 7 8 Iout[A] CP-T 48/5.0 Uout in V 56 48 40 32 24 16 8 @ 3 x 400 V supply U/I Hiccup mode after 2-5 s overload 4 8 12 16 20 24 28 32 36 40 Iout in A CP-T 48/20.0 -- Temperature curves at rated load Pout [%] 100 90 80 70 60 50 40 30 20 10 -40 CP-T 24/40.0, CP-T 48/20.0 60 70 Ta [°C] 2CDC 272 026 F0211 Pout [%] 100 90 80 70 60 50 40 30 20 10 -30 CP-T 24/20.0, CP-T 48/10.0 60 70 Ta [°C] 2CDC 272 030 F0211 Pout [%] 100 90 80 70 60 50 40 30 20 10 -40 60 70 Ta [°C] CP-T 24/5.0, CP-T 24/10.0, CP-T 48/5.0 2CDC 272 028 F0211 2CDC 272 025 F0211 286 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-T range Technical diagrams -- Dimensional drawings Dimensions in mm, inches 118.8 4.68`` 111.9 4.41`` 118.8 4.68`` 111.89943.4.51`` 150 5.91`` 2CDC 272 021 F0009 131 5.16`` 124 4.88`` 2CDC 272 022 F0009 131 5.16`` 124 4.88`` 2CDC 272 023 F0009 CP-T 24/5.0 120.9 4.76`` 112.5 4.43`` CP-T 24/40.0, CP-T 48/20.0 131 5.16`` 124 4.88`` 2CDC 272 011 F0016 CP-T 24/10.0, CP-T 48/5.0 CP-T 24/20.0, CP-T 48/10.0 275.8 10.86`` ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 287 288 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 289 -- CP-C.1 range Table of contents 290 Benefits and advantages 292 Operating controls 293 Applications 294 Ordering details 295 Technical data 307 Technical diagrams 290 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Benefits and advantages The high-performance CP-C.1 power supplies are ABB's most advanced range. With excellent efficiency, high reliability and innovative functionality, it is ready to take on the most demanding of industrial applications These power supplies have a 150 % integrated power reserve, operate at an efficiency of up to 94 % and are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals, CP-C.1 power supplies are the preferred choice for professional DC applications. ATEX and IECEx approvals are available for the use in hazardous areas. 24 7 Continuous operation · Power reserve design to allow performance with up to 150 % more current · Redundancy setup of the application possible to allow parallel operation · Long lifetime · High peak currents for switching on capacitive loads are supported $ Project cost reduction · Up to 94 % efficiency saves money for energy during operation · Less need for external cooling in the cabinet · Small size to reduce space needed in panel Reliabel in harsh conditions · Extended ambient temperature range during operation -40...+70 °C with coated PCBA version · IECEx/ATEX approvals for hazardous locations available · High MTBF values ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 291 -- CP-C.1 range Benefits and advantages Characteristics · Rated output voltage 24 V DC · Power reserve design delivers up to 150 % at Ta 40 °C · Output voltage adjustable via front-facing rotary potentiometer "OUTPUT Adjust", 22.5-28.5 V · High efficiency of up to 94 % · Low power dissipation and low heating · Free convection cooling (no forced cooling) · Devices with coated PCBAs for harsh environments and with extended temperature range · Open-circuit, overload and short-circuit stable · Integrated input fuse · OUTPUT OK - signaling output "13-14" (relay), Power reserve signaling output "I > IR (transistor) · Redundancy unit offers true redundancy, available as accessory · Various approvals and marks Main benefits The primary switch mode power supply CP-C.1 has a wide range of AC and DC input voltages. Furthermore, the CP-C.1 is equipped with capacitors that ensure a hold-up time of at least 50 ms. This enables worldwide usage and permits safe operation in fluctuating networks and battery-powered applications. With their robust metallic housing and the reliable construction, CP-C.1 power supplies are suitable for applications in industrial environments. The CP-C.1-C units have coated PCBAs, which enables their use in harsh industrial environments. The power reserve of up to 150 % enables trouble-free starting of heavy loads eliminating the need for an oversized power supply. Signaling output To communicate the status of the power supply, the CP-C.1 is equipped with a relay output to signal OUTPUT OK as well as a transistor output I > IR to indicate when the power reserve is active. These signals can be used for communication with a higher level control system, e.g. a PLC. Depending on the logic of the higher level control system, an appropriate action is initiated by forwarding the signal. The receptor of this signal could be a contactor, a signal tower, or an interface relay. 292 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Operating controls 13-14: Relay output to signal `Output OK' I > IR: Power reserve transistor output to signal `Power reserve is active' Side mounting screw holes for DIN rail adapter / lateral mounting OUTPUT Adjust: Rotary potentiometer Adjustment of output voltage 22.5-28.5 V DC OUTPUT L+, L: Output terminals 24 V DC Indication of operational states OUTPUT OK: Green LED POWER RESERVE I > IR: Yellow LED Circuit diagram INPUT L(+), N(-), PE: Input terminals 85-264 V AC / 90 - 300 V DC ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 293 -- CP-C.1 range Applications Application The primary switch mode power supply CP-C.1 has a wide range of AC and DC input voltages. Furthermore, the CP-C.1 is equipped with capacitors that ensure a hold-up time of at least 50 ms. This enables worldwide usage and permits safe operation in fluctuating networks and battery-powered applications. With their robust metallic housing and reliable construction, CP-C.1 power supplies are suitable for applications in industrial environments. The CP-C.1-C units have coated PCBAs, which enables their use in the harshest of industrial environments. usage in even harsh industrial environments. The power reserve of up to 150 % enables trouble-free starting of heavy loads eliminating the need for an oversized power supply. Adjustable output voltage The CP-C.1 range power supplies feature a continuously adjustable output voltage of 22.5 to 28.5 V DC. Thus, they can be optimally adapted to the applications, e.g. compensating the voltage drop caused by a long line length. Signaling output To communicate the status of the power supply, the CP-C.1 is equipped with a relay output to signal OUTPUT OK as well as a transistor output I > IR to indicate when the power reserve is active. These signals can be used for communication with a higher level control system, e.g. a PLC. Power reserve The primary switch mode power supply CP-C.1 is equipped with a power reserve functionality to handle the start-up of particularly heavy loads (e.g. of a capacitive load or a motor). To ensure that heavy loads are started up, the CP-C.1 delivers additionally up to 150 % of the rated output current to secure the operation of the application. This status is displayed by the yellow LED labelled POWER RESERVE I > IR. 294 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Ordering details CP-C.1 24/5.0 CP-C.1 24/5.0-C CP-C.1 24/10.0 CP-C.1 24/10.0-C CP-C.1 24/20.0 CP-C.1 24/20.0-C 2CDC 271 009 F0017 2CDC 271 010 V0017 2CDC 271 011 V0017 Description High-performance CP-C.1 power supplies are ABB's most advanced range. With excellent efficiency, high reliability, and innovative functionality, it is ready to take on the most demanding industrial applications. These power supplies have up to 50 % integrated power reserve and operate at an efficiency of up to 94 %. They are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals, the CP-C.1 power supplies are the preferred choice for professional DC applications. -- Ordering details - CP-C.1 Input voltage range 85-264 V AC, 90-300 V DC Rated output voltage / current 24 V DC / 5 A PCBA Color Type uncoated dark grey CP-C.1 24/5.0 Order code 1SVR360563R1001 24 V DC / 10 A CP-C.1 24/10.0 1SVR360663R1001 24 V DC / 20 A CP-C.1 24/20.0 1SVR360763R1001 24 V DC / 5 A coated CP-C.1 24/5.0-C 1SVR360563R2001 24 V DC / 10 A CP-C.1 24/10.0-C 1SVR360663R2001 24 V DC / 20 A CP-C.1 24/20.0-C 1SVR360763R2001 24 V DC / 5 A uncoated light grey CP-C.1 24/5.0-L 1SVR361563R1001 24 V DC / 10 A CP-C.1 24/10.0-L 1SVR361663R1001 24 V DC / 20 A CP-C.1 24/20.0-L 1SVR361763R1001 Weight (1 pc.) kg (lb) 0.87 (1.92) 1.21 (2.67) 1.70 (3.75) 0.87 (1.92) 1.24 (2.73) 1.72 (3.79) 0.87 (1.92) 1.21 (2.67) 1.70 (3.75) CP-C.1 24/5.0 light grey CP-C.1 24/10.0 light grey ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 295 -- CP-C.1 range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C Input circuit - Supply circuit L (+), N (-) Rated input voltage Uin Input voltage range 100-240 V AC, 90-300 V DC AC 85-264 V AC DC 90-300 V DC Typical input current at 115 V AC 1.1 A at 230 V AC 0.6 A Typical power consumption at 230 V AC 132 W Rated frequency DC, 50/60 Hz Frequency range AC 45-65 Hz Inrush current, cold state < 8 A Let-through energy I2t , cold state at 230 V AC < 1 A2s Discharge current towards PE < 3.5 mA Hold-up time at 115 V AC min. 50 ms at 230 V AC min. 50 ms Internal input fuse T4.0 A, not exchangeable Recommended backup fuse for wire protection at 1.5 mm2 1 pole miniature circuit breaker ABB type S 200 characteristic B or C max. rating 16 A Power factor correction (PFC) yes, active Transient overvoltage protection yes, varistor User interface Indication of operational states Output voltage Power reserve Output circuit - Power output LED `OUTPUT OK ` (green) LED `I > IR' (yellow) ON flashing OFF ON 92 % adjusted Uout 90 % adjusted Uout I IR I > IR L+, L- Rated output voltage 24V DC Tolerance of the output voltage ± 1% Adjustment range of the output voltage 22.5-28.5 V DC Rated output power 120 W Rated output current IR Reserve output current Short-circuit current limiting - 25 °C m Ta m 60°C 5.0 A - 40 °C m Ta m 60°C - 25 °C m Ta m 40 °C 7.5 A continuously - 40 °C m Ta m 40 °C - 7.6 A 5.0 A 7.5 A continuously Derating of the output current Deviation width of output voltage 60 °C < Ta m 70 °C 2.5 %/°C static output voltage deviaton 25-100 % < 1%, class C dynamical 0-100 % < 2%, class A change of input voltage within < 1 ms, class A the rated input voltage Recovery time TA Starting time after applying the supply voltage < 1 ms, class A < 500 ms, class C Rise time Residual ripple and switching peaks Parallel connection < 10 ms BW = 20 MHz < 120 mVpp, class A yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical Series connection yes, max. 2 devices to increase voltage 296 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical data Type No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C U/I characteristic curve with power reserve continuous shortcircuit stability current limiting 35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart No-load protection Starting of capacitive loads Signaling outputs OUTPUT OK signaling output Type of output ON (contact closed) OFF (contact open) Contact ratings continuous no-load stability yes 13-14 relay, n/o contact 92 % adjusted Uout 90 % adjusted Uout max. switching voltage / current 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load) min. switching voltage / current 5 V DC / 1 mA POWER RESERVE signaling output Type of output Active / ON (closed) Inactive / OFF (open) Ratings General data I > IR transistor, short-circuit proof I > IR I IR voltage/current 24 V DC / 20 mA Efficiency Power loss Duty cycle MTBF Dimensions Material of housing Mounting Mounting position Minimum distance to other units Degree of protection (IEC/EN 60529) Protection class (IEC/EN 61140) Electrical connection at rated output power up to 93 % at rated output power 12 W at 50% of rated output power 8 W at no load < 3.6 W 100 % acc. to MIL 217 HDBK on request see "Dimensional drawings" cover zinc-coated sheet-steel housing shell aluminium front plastic, PA6, V-0 DIN rail (IEC/EN 60715), snap-on mounting see "Mounting positions" in the data sheet horizontal 25 mm (0.98 in) vertical 25 mm (0.98 in) housing / terminals IP20 / IP20 I Input circuits (L(+), N(-), PE) Connecting capacity Stripping length Tightening torque Recommended screw driver Output circuits (L+, L+, L-, L-) Connecting capacity Stripping length Tightening torque Recommended screw driver rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 297 -- CP-C.1 range Technical data Type CP-C.1 24/5.0, CP-C.1 24/5.0-L Signaling output (13-14, I > IR) Connecting capacity rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) Stripping length 8 mm (0.315 in) Tightening torque 0.5 Nm (4.4 lb.in) Recommended screw driver PH1 / Ø 4.0 x 0.8 mm Maximum cable length (applicable for I>IR) 30 m Environmental data CP-C.1 24/5.0-C Ambient temperature range operation -25...+70 °C (-13... +158 °F) -40...+70 °C (-40...+158 °F) rated output power -25...+60 °C (-13... +140 °F) -40...+60 °C (-40...+140 °F) storage -40...+85 °C (-40...+185 °F) transportation -40...+85 °C (-40...+185 °F) Climatic class (IEC/EN 60721-3-1) storage 1K2 (-40...+85 °C / -40...+185 °F) Climatic class (IEC/EN 60721-3-2) transportation 2K2 (-40...+85 °C / -40...+185 °F) Climatic class (IEC/EN 60721-3-3) operation 3K3 (-25...+70 °C / -13...+158 °F) 3K3 (-40...+70 °C / -40...+158 °F) Damp heat, cyclic (IEC/EN 60068230) test Db: 55 °C, 2 cycles Vibration (IEC/EN 6006826) test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis Shock, halfsine (IEC/EN 60068227) test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis Coated PCBA no yes Gaseous corrosive environment withstand test (IEC/EN 60068-2-60) - testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S 100 ± 10 ppb - SO2/SO3 300 ± 20 ppb - Cl2 100 ± 10 ppb - NOx 1250 ± 20 ppb Isolation data Rated impulse withstand voltage Uimp (EN 50178) Rated insulation voltage Ui (EN 50178) Overvoltage category (EN 50178) Overvoltage category (IEC/EN 60950-1) Pollution degree Protective separation (IEC/EN 60950-1) input circuit / output circuit 4 kV (1.2/50 µs) input circuit / PE 4 kV (1.2/50 µs) input circuit / relay contact 4 kV (1.2/50 µs) output circuit / relay contact 0.5 kV (1.2/50 µs) relay contact / PE 0.5 kV (1.2/50 µs) output circuit / PE 0.5 kV (1.2/50 µs) input circuit / output circuit 300 V input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V relay contact / PE 50 V output circuit / PE 50 V < 2000 m III 2000...5000 m II < 2000 m II 2000...5000 m I 2 input circuit / output circuit yes input circuit / relay contact yes 298 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical data Type Standards / Directives Standards Low Voltage Directive EMC Directive ATEX Directive RoHS Directive Electrical safety Industrial control equipment Electronic equipment for use in power installations Protective extra low voltage Safety extra low voltage Limitation of harmonic line currents Electromagnetic compatibility Low-voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) Interference immunity to electrostatic discharge (ESD) radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz Interference emission limits for harmonic current emissions limitation of voltage changes etc. Information technology equipment radio disturbance characteristics limits and methods of measurement Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement Voltage sags Federal Communications Commission CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C IEC/EN 61204 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 60950-1 UL 508 / CSA 22.2 No 107.1 EN 50178 PELV (EN 50178) SELV (IEC/EN 60950-1) IEC/EN 61000-3-2 2014/34/EU IEC/EN 61204-3 IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4, 8 kV / 15 kV (criterion A) IEC/EN 61000-4-3 level 3, 10 V/m (criterion A) IEC/EN 61000-4-4 level 4, 4 kV / 2 kV (criterion A) IEC/EN 61000-4-5 level 4, L/N 2 kV (criterion A) level 4, L,N/PE 4 kV ( criterion A) IEC/EN 61000-4-6 level 3, 10 V (criterion A) IEC/EN 61000-4-11 class 3 IEC/EN 61000-4-13 class 3 (criterion A) IEC/EN 61000-4-16 level 3, 10 V IEC/EN 61000-6-3 IEC/EN 61000-3-2 class A IEC/EN 61000-3-3 compliant IEC/CISPR 22, class B EN 55022 IEC/CISPR 11, class B EN 55011 SEMI F47 passed FCC15 compliant ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 299 -- CP-C.1 range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C Input circuit - Supply circuit L (+), N (-) Rated input voltage Uin Input voltage range 100-240 V AC, 90-300 V DC AC 85-264 V AC DC 90-300 V DC Typical input current at 115 V AC 2.3 A at 230 V AC 1.2 A Typical power consumption at 230 V AC 256 W Rated frequency DC, 50/60 Hz Frequency range AC 45-65 Hz Inrush current, cold state < 11 A Let-through energy I2t , cold state at 230 V AC < 1,5 A²s Discharge current towards PE < 3.5 mA Hold-up time at 115 V AC min. 40 ms at 230 V AC min. 40 ms Internal input fuse T6.3 A, not exchangeable Recommended backup fuse for wire protection at 1.5 mm2 1 pole miniature circuit breaker ABB type S 200 characteristic B or C max. rating 16 A Power factor correction (PFC) yes, active Transient overvoltage protection yes, varistor User interface Indication of operational states Output voltage LED `OUTPUT OK ` (green) Power reserve Output circuit - Power output LED `I > IR' (yellow) ON flashing OFF ON 92 % adjusted Uout 90 % adjusted Uout I IR I > IR L+, L- Rated output voltage 24V DC Tolerance of the output voltage ±1% Adjustment range of the output voltage 22.5-28.5 V DC Rated output power 240W Rated output current IR Reserve output current Short-circuit current limiting - 25 °C m Ta m 60°C - 40 °C m Ta m 60°C - 25 °C m Ta m 40 °C - 40 °C m Ta m 60°C 10.0A 15.0A continuously 15.5 A 10.0A 15.0 A continuously 15.5 A Derating of the output current Deviation width of output voltage 60 °C < Ta m 70 °C 2.5 %/°C static output voltage deviation 25-100 % < 1%, class C 2.5 %/°C dynamic 0-100 % < 5 %, class B change of input voltage within the rated < 1 ms, class A input voltage Recovery time TA Starting time after applying the supply voltage Rise time Residual ripple and switching peaks Parallel connection < 1 ms, class A < 500 ms, class C < 10 ms BW = 20 MHz < 120 mVpp, class A yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical Series connection yes, max. 2 devices to increase voltage 300 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical data Type No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C U/I characteristic curve with power reserve continuous shortcircuit stability current limiting 35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart No-load protection Starting of capacitive loads Signaling outputs continuous no-load stability yes OUTPUT OK signaling output Type of output ON (contact closed) OFF (contact open) Contact ratings 13-14 relay, n/o contact 92 % adjusted Uout 90 % adjusted Uout max. switching voltage / current 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load) min. switching voltage / current 5 V DC / 1 mA POWER RESERVE signaling output Type of output Active / ON (closed) Inactive / OFF (open) Ratings General data I > IR voltage/current transistor, short-circuit proof I > IR I IR 24 V DC / 20 mA Efficiency Power loss Duty cycle MTBF Dimensions Material of housing Mounting Mounting position Minimum distance to other units Degree of protection (IEC/EN 60529) Protection class (IEC/EN 61140) Electrical connection Input circuits (L(+), N(-), PE) at rated output power up to 94 % at rated output power 16 W at 50% of rated output power 12 W at no load < 3.6 W 100 % acc. to MIL 217 HDBK on request see "Dimensional drawings" cover zinc-coated sheet-steel housing shell aluminium front plastic, PA6, V-0 DIN rail (IEC/EN 60715), snap-on mounting see "Mounting positions" in the data sheet horizontal 25 mm (0.98 in) vertical 25 mm (0.98 in) housing / terminals IP20 / IP20 I Connecting capacity Stripping length Tightening torque Recommended screw driver rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm Output circuits (L+, L+, L-, L-) Connecting capacity Stripping length Tightening torque Recommended screw driver rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 301 -- CP-C.1 range Technical data Type Signaling output (13-14, I > IR) Connecting capacity Stripping length Tightening torque Recommended screw driver Maximum cable length (applicable for I>IR) Environmental data CP-C.1 24/10.0, CP-C.1 24/10.0-L rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm 30 m CP-C.1 24/10.0-C Ambient temperature range Climatic class (IEC/EN 60721-3-1) Climatic class (IEC/EN 60721-3-2) Climatic class (IEC/EN 60721-3-3) operation -25...+70 °C (-13...+158 °F) rated output power -25...+60 °C (-13...+140 °F) storage -40...+85 °C (-40...+185 °F) transportation -40...+85 °C (-40...+185 °F) storage 1K2 (-40...+85 °C / -40...+185 °F) transportation 2K2 (-40...+85 °C / -40...+185 °F) operation 3K3 (-25...+70 °C / -13...+158 °F) -40...+70 °C (-40...+158 °F) -40...+60 °C (-40...+140 °F) 3K3 (-40...+70 °C / -40...+158 °F) Damp heat, cyclic (IEC/EN 60068230) Vibration (IEC/EN 6006826) test Db: 55 °C, 2 cycles test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis Shock, halfsine (IEC/EN 60068227) test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis Coated PCBA no Gaseous corrosive environment withstand test (IEC/EN 60068-2-60) - Isolation data yes testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S 100 ± 10 ppb - SO2/SO3 300 ± 20 ppb - Cl2 100 ± 10 ppb - NOx 1250 ± 20 ppb Rated impulse withstand voltage Uimp (EN 50178) Rated insulation voltage Ui (EN 50178) Overvoltage category (EN 50178) Overvoltage category (IEC/EN 60950-1) Pollution degree Protective separation (IEC/EN 60950-1) input circuit / output circuit 4 kV (1.2/50 µs) input circuit / PE 4 kV (1.2/50 µs) input circuit / relay contact 4 kV (1.2/50 µs) output circuit / relay contact 0.5 kV (1.2/50 µs) relay contact / PE 0.5 kV (1.2/50 µs) output circuit / PE 0.5 kV (1.2/50 µs) input circuit / output circuit 300 V input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V relay contact / PE 50 V output circuit / PE 50 V < 2000 m III 2000...5000 m II < 2000 m II 2000...5000 m I 2 input circuit / output circuit yes input circuit / relay contact yes 302 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical data Type Standards / Directives Standards Low Voltage Directive EMC Directive ATEX Directive RoHS Directive Electrical safety Industrial control equipment / General Use Power Supplies Electronic equipment for use in power installations Protective extra low voltage Safety extra low voltage Limitation of harmonic line currents Electromagnetic compatibility Low-voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) Interference immunity to electrostatic discharge (ESD) radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz Interference emission limits for harmonic current emissions limitation of voltage changes etc. Information technology equipment radio disturbance characteristics limits and methods of measurement Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement Voltage sags Federal Communications Commission CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C IEC/EN 61204 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 60950-1 UL 508 / CSA 22.2 No 107.1 EN 50178 PELV (EN 50178) SELV (IEC/EN 60950-1) IEC/EN 61000-3-2 2014/34/EU IEC/EN 61204-3 IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4, 8 kV / 15 kV (criterion A) IEC/EN 61000-4-3 level 3, 10 V/m (criterion A) IEC/EN 61000-4-4 level 4, 4 kV / 2 kV (criterion A) IEC/EN 61000-4-5 level 4, L/N 2 kV (criterion A) level 4, L,N/PE 4 kV (criterion A) IEC/EN 61000-4-6 level 3, 10 V (criterion A) IEC/EN 61000-4-11 class 3 IEC/EN 61000-4-13 class 3 (Criterion A) IEC/EN 61000-4-16 level 3, 10 V IEC/EN 61000-6-3 IEC/EN 61000-3-2 class A IEC/EN 61000-3-3 compliant IEC/CISPR 22, class B EN 55022 IEC/CISPR 11, class B EN 55011 SEMI F47 passed FCC15 compliant ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 303 -- CP-C.1 range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C Input circuit - Supply circuit L (+), N (-) Rated input voltage Uin Input voltage range 100-240 V AC, 90-300 V DC AC 85-264 V AC DC 90-300 V DC Typical input current at 115 V AC 4.6 A at 230 V AC 2.3 A Typical power consumption at 230 V AC 508 W Rated frequency DC, 50/60 Hz Frequency range AC 45-65 Hz Inrush current, cold state < 11 A Let-through energy I2t , cold state at 230 V AC < 3 A2s Discharge current towards PE < 3.5 mA Hold-up time at 115 V AC min. 40 ms at 230 V AC min. 40 ms Internal input fuse T12 A, not exchangeable Recommended backup fuse for wire protection at 1.5 mm2 1 pole miniature circuit breaker ABB type S 200 characteristic B or C max. rating 16 A Power factor correction (PFC) yes, active Transient overvoltage protection yes, varistor User interface Indication of operational states Output voltage LED `OUTPUT OK ` (green) Power reserve Output circuit - Power output LED `I > IR' (yellow) ON flashing OFF ON 92 % adjusted Uout 90 % adjusted Uout I IR I > IR L+, L- Rated output voltage 24V DC Tolerance of the output voltage ± 1% Adjustment range of the output voltage 22.5-28.5 V DC Rated output power 480 W Rated output current IR Reserve output current Short-circuit current limiting - 25 °C m Ta m 60°C 20 A - 40 °C m Ta m 60°C - 25 °C m Ta m 40 °C 26.0 A continuously - 40 °C m Ta m 60°C - 27.7 A 20 A 26.0 A continuously Derating of the output current Deviation width of output voltage 60 °C < Ta m 70 °C 2.5 %/°C static output voltage deviaton 25-100 % < 1 %, class C dynamical 0-100 % < 5 %, class B change of input voltage within the rated < 5 ms, class B input voltage Recovery time TA Starting time after applying the supply voltage Rise time Residual ripple and switching peaks Parallel connection < 1 ms, class A < 500 ms, class C < 10 ms BW = 20 MHz < 120 mVpp, class A yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical Series connection yes, max. 2 devices to increase voltage 304 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical data Type No-load, overload and short-circuit behavior CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection No-load protection Starting of capacitive loads Signaling outputs U/I characteristic curve with power reserve continuous shortcircuit stability current limiting 35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart continuous no-load stability yes OUTPUT OK signaling output Type of output 13-14 relay, n/o contact ON (contact closed) OFF (contact open) Contact ratings max. switching voltage / current 92 % adjusted Uout 90 % adjusted Uout 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load) min. switching voltage / current 5 V DC / 1 mA POWER RESERVE signaling output Type of output Active / ON (closed) Inactive / OFF (open) Ratings General data Efficiency Power loss Duty cycle MTBF Dimensions Material of housing Mounting Mounting position Minimum distance to other units Degree of protection (IEC/EN 60529) Protection class (IEC/EN 61140) Electrical connection Input circuits (L(+), N(-), PE) Connecting capacity Stripping length Tightening torque Recommended screw driver I > IR voltage/current transistor, short-circuit proof I > IR I IR 24 V DC / 20 mA at rated output power at rated output power at 50 % of rated output power at no load acc. to MIL 217 HDBK cover housing shell front horizontal vertical housing / terminals up to 94 % 28 W 17 W < 3.6 W 100 % on request see "Dimensional drawings" zinc-coated sheet-steel aluminium plastic, PA6, V-0 DIN rail (IEC/EN 60715), snap-on mounting see "Mounting positions" in the data sheet 25 mm (0.98 in) 25 mm (0.98 in) IP20 / IP20 I rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) 8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 305 -- CP-C.1 range Technical data Type CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C Output circuits (L+, L+, L-, L-) Connecting capacity Stripping length Tightening torque Recommended screw driver Signaling output (13-14, I > IR) Connecting capacity rigid fine-strand with(out) wire end ferrule 2.5-16.0 mm² (12-6 AWG) 2.5-10 mm² (12-8 AWG) 10 mm ( 0.394 in) 1.2 Nm (10.5 lb-in) PH1 / Ø 4.0 x 0.8 mm rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG) Stripping length 8 mm (0.315 in) Tightening torque 0.5 Nm (4.4 lb.in) Recommended screw driver PH1 / Ø 4.0 x 0.8 mm Maximum cable length (applicable for I>IR) Environmental data 30 m Ambient temperature range Climatic class (IEC/EN 60721-3-1) Climatic class (IEC/EN 60721-3-2) Climatic class (IEC/EN 60721-3-3) operation rated output power storage transportation storage transportation operation Damp heat, cyclic (IEC/EN 60068230) Vibration (IEC/EN 6006826) Shock, halfsine (IEC/EN 60068227) Coated PCBA Gaseous corrosive environment withstand test (IEC/EN 60068-2-60) -25...+70 °C (-13...+158 °F) -40...+70 °C (-40...+158 °F) -25...+60 °C (-13...+140 °F) -40...+60 °C (-40...+140 °F) -40...+85 °C (-40...+185 °F) -40...+85 °C (-40...+185 °F) 1K2 (-40...+85 °C / -40...+185 °F) 2K2 (-40...+85 °C / -40...+185 °F) 3K3 (-25...+70 °C / -13...+158 °F) 3K3 (-40...+70 °C / -40... +158 °F) test Db: 55 °C, 2 cycles test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis no yes - testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S 100 ± 10 ppb - SO2/SO3 300 ± 20 ppb - Cl2 100 ± 10 ppb - NOx 1250 ± 20 ppb 306 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical data Type Isolation data Rated impulse withstand voltage Uimp (EN 50178) Rated insulation voltage Ui (EN 50178) Overvoltage category (EN 50178) Overvoltage category (IEC/EN 60950-1) Pollution degree Protective separation (IEC/EN 60950-1) Standards / Directives CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C input circuit / output circuit 4 kV (1.2/50 µs) input circuit / PE 4 kV (1.2/50 µs) input circuit / relay contact 4 kV (1.2/50 µs) output circuit / relay contact 0.5 kV (1.2/50 µs) relay contact / PE 0.5 kV (1.2/50 µs) output circuit / PE 0.5 kV (1.2/50 µs) input circuit / output circuit 300 V input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V relay contact / PE 50 V output circuit / PE 50 V < 2000 m III 2000...5000 m II < 2000 m II 2000...5000 m I 2 input circuit / output circuit yes input circuit / relay contact yes Standards Low Voltage Directive EMC Directive ATEX Directive RoHS Directive Electrical safety Industrial control equipment / General Use Power Supplies Electronic equipment for use in power installations Protective extra low voltage Safety extra low voltage Limitation of harmonic line currents Electromagnetic compatibility IEC/EN 61204 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 60950-1 UL 508 / CSA 22.2 No 107.1 EN 50178 PELV (EN 50178) SELV (IEC/EN 60950-1) IEC/EN 61000-3-2 2014/34/EU Low-voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) IEC/EN 61204-3 Interference immunity to electrostatic discharge (ESD) radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4, 8 kV / 15 kV (criterion A) IEC/EN 61000-4-3 level 3, 10 V/m (criterion A) IEC/EN 61000-4-4 level 4, 4 kV / 2 kV (criterion A) IEC/EN 61000-4-5 level 4, L/N 2 kV (criterion A) level 4, L,N/PE 4 kV (criterion A) conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz IEC/EN 61000-4-6 level 3, 10 V (criterion A) IEC/EN 61000-4-11 class 3 IEC/EN 61000-4-13 class 3 (Criterion A) IEC/EN 61000-4-16 level 3, 10 V Interference emission limits for harmonic current emissions limitation of voltage changes etc. Information technology equipment radio disturbance characteristics limits and methods of measurement IEC/EN 61000-6-3 IEC/EN 61000-3-2 class A IEC/EN 61000-3-3 compliant IEC/CISPR 22, class B EN 55022 Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement Voltage sags Federal Communications Commission IEC/CISPR 11, class B EN 55011 SEMI F47 passed FCC15 compliant ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 307 -- CP-C.1 range Technical diagrams 2CDC 272 027 F0215 -- CP-C.1 24/5.0 , CP-C.1 24/5.0-L and CP-C.1 24/5.0-C Efficiency [%] 95.0 90.0 85.0 80.0 75.0 0 1 2 3 4 5 6 7 8 Iout [A] Typical efficiency over output current 2CDC 272 023 F0215 Efficiency [%] 94.0 93.0 92.0 91.0 90.0 89.0 85 110 130 150 170 190 210 Typical efficiency over AC input voltage 230 250 Uin [VAC] Power loss [W] 15 Power loss [W] 15 2CDC 272 025 F0215 Efficiency [%] 93.0 92.5 at 150% load at 100% load 92.0 91.5 91.0 -25 -15 -5 5 15 25 35 45 55 65 Ta [°C] Typical efficiency over ambient temperature 10 10 2CDC 272 024 F0215 5 5 2CDC 272 026 F0215 0 85 110 130 150 170 190 210 230 250 Uin [VAC] Typical power loss over AC input voltage 0 0 1 2 3 4 5 6 7 8 Iout [A] Typical power loss over output current -- CP-C.1 24/10.0, CP-C.1 24/10.0 -L and CP-C.1 24/10.0-C Efficiency [%] 95.0 90.0 85.0 0 2 4 6 8 10 12 Typical efficiency over output current 14 Iout [A] 2CDC 272 007 F0215 Efficiency [%] 94.5 94.0 93.5 93.0 92.5 92.0 85 110 130 150 170 190 210 Typical efficiency over AC input voltage 230 250 Uin [VAC] Power loss [W] 25 20 15 10 5 0 85 110 130 150 170 190 210 230 250 Uin [VAC] Typical power loss over AC input voltage 2CDC 272 010 F0215 Power loss [W] 25 20 15 10 5 0 0 2 4 6 8 10 12 14 Iout [A] Typical power loss over output current 2CDC 272 008 F0215 2CDC 272 009 F0215 Efficiency [%] 94.5 94.0 at 100% load at 150% load 93.5 93.0 92.5 92.0 -25 -15 -5 5 15 25 35 45 55 65 Ta [°C] Typical efficiency over ambient temperature 2CDC 272 011 F0215 308 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical diagrams 2CDC 272 008 F0216 -- CP-C.1 24/20.0, CP-C.1 24/20.0-L and CP-C.1 24/20.0-C Efficiency [%] 95.0 90.0 85.0 80.0 5 10 15 20 25 Iout [A] Typical efficiency over output current 2CDC 272 003 F0216 Efficiency [%] 94.5 94.0 93.5 93.0 92.5 92.0 91.5 85 110 130 150 170 190 210 230 250 Uin [VAC] Typical efficiency over AC input voltage 2CDC 272 006 F0216 Efficiency [%] 94.5 94.0 at 100% load at 130% load 93.5 93.0 92.5 92.0 -25 -15 -5 5 15 25 35 45 55 65 Ta [°C] Typical efficiency over ambient temperature 2CDC 272 005 F0216 Power loss [W] 40 35 30 25 85 110 130 150 170 190 210 230 250 Uin [VAC] Typical power loss over AC input voltage 2CDC 272 007 F0216 Power loss [W] 40 30 20 10 0 04 8 12 16 20 24 Iout [A] Typical power loss over output current ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 309 -- CP-C.1 range Technical diagrams 2CDC 272 019 F0015 -- Characteristic curve of output at Ta = 25 °C 30 25 Output voltage [ V ] 20 15 10 5 0 0 123456 Output current [A] at 24 V at 22.5 V 789 at 28.5 V CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C 2CDC 272 017 F0015 Output voltage [ V ] 30 25 20 15 10 5 0 0 2 4 6 8 10 12 14 16 18 Output current [A] at 24 V at 22.5 V at 28.5 V CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C -- Characteristic curve of temperature at Uout = 24 V Output current [A] 8 7 6 5 IR 4 3 2 1 0 -25 Power reserve -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] CP-C.1 24/5.0, CP-C.1 24/5.0-L 2CDC 272 020 F0015 Output current [A] 16 14 12 10 IR 8 6 4 2 0 -25 Power reserve -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] CP-C.1 24/10.0, CP-C.1 24/10.0-L 2CDC 272 002 F0216 Output current [A] 2CDC 272 018 F0015 Output voltage [ V ] 30 25 20 15 10 5 0 0 4 8 12 16 20 24 28 32 34 Output current [A] at 24 V at 22.5 V at 28.5 V CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C 32 28 24 20 IR 16 12 8 4 0 -25 Power reserve -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] CP-C.1 24/20.0, CP-C.1 24/20.0-L Output current [A] 8 7 6 Power reserve 5 IR 4 3 2 1 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] CP-C.1 24/5.0-C 2CDC 272 014 F0216 Output current [A] 16 14 12 Power reserve 10 IR 8 6 4 2 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] CP-C.1 24/10.0-C 2CDC 272 015 F0216 Output current [A] 32 28 24 20 IR 16 Power reserve 12 8 4 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] CP-C.1 24/20.0-C 2CDC 272 012 F0216 2CDC 272 013 F0216 310 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-C.1 range Technical diagrams -- Dimensional drawings Dimensions in mm, inches 129.8 5.11" 126.8 4.99" 136.0 5.35" 40.00 1.57" IEC/EN 60715 TH 35-7.5 TH 35-15 13 14 I > IR L+ L+ L- L- OUTPUT 24 V DC 5 A CP-C.1 24/5.0 OUTPUT OK POWER RESERVE I > IR OUTPUT Adjust 22.5-28.5 V L L+ L+ L- N PWM L- INPUT 100-240 V AC L(+) N(-) CP-C.1 24/5.0 60.00 2.36" L+ L+ L- L- 13 14 I > IR OUTPUT 24 V DC 10 A CP-C.1 24/10.0 OUTPUT OK POWER RESERVE I > IR OUTPUT Adjust 22.5-28.5 V L L+ L+ L- N PWM L- INPUT 100-240 V AC L(+) N(-) CP-C.1 24/10.0 82.00 3.23" L+ L+ L- L- 13 14 I > IR OUTPUT 24 V DC 20 A CP-C.1 24/20.0 OUTPUT OK POWER RESERVE I > IR OUTPUT Adjust 22.5-28.5 V L L+ L+ L- N PWM L- INPUT 100-240 V AC L(+) N(-) CP-C.1 24/20.0 129.4 5.09" 129.4 5.09" 129.4 5.09" 2CDC 272 012 F0017 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 311 312 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 313 -- Power supplies for building applications Table of contents 314 CP-D range 314 Benefits and advantages 316 Operation controls 317 Applications 318 Ordering details 319 Technical data 323 Technical diagrams 314 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-D range Benefits and advantages Thanks to its compact modular housing, the CP-D range is ideal for building applications and installation. For maximum flexibility in operation, six different versions are available, from 10 W up to 100 W. Their wide input voltage range allows their use in global applications. Easy to install The CP-D range is easy to adjust and ideally suited for installation in distribution panels due to its width being only 18 to 90 mm. Global availability The product can be used in any installation in the world. Giving you the confidence of worldwide sourcing no matter where you build, install or operate your equipment. Speed up your projects Data available for common planning software: Less engineering time required. ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 315 -- CP-D range Benefits and advantages Characteristics · Output voltages 12 V, 24 V DC · Adjustable output voltages (devices > 10 W) · Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A · Power range 10 W, 25 W, 30 W, 60 W, 100 W · Wide range input 100-240 V AC (90-264 V AC, 120-375 V DC) · High efficiency of up to 89 % · Low power dissipation and low heating · Free convection cooling (no forced cooling with ventilators) · Ambient temperature range during operation -40...+70 °C · Open-circuit, overload and short-circuit stable · Integrated input fuse · LEDs for status indication · Light-grey housing in RAL 7035 · Various approvals and marks Main benefits Adjustable output voltage The CP-D range types > 10 W feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, for example compensating the voltage drop caused by a long line length. Wide range input Optimized for world-wide applications: The CP-D power supplies can be supplied with 90-264 V AC or 120-375 V DC. Width and structural form With their width being only 18 to 90 mm, the CP-D range switch mode power supplies are ideally suited for installation in distribution panels. 316 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-D range Operation controls OUTPUT ++/: terminals output 12 V, 24 V OUTPUT Adjust: potentiometer adjustment of output voltage*) Indication of operational states DC ON: green LED output voltage applied DC LOW: red LED output voltage too low *) only for devices > 10 W. 12 V version: 12...14 V DC, 24 V version: 24 ... 28 V DC. Circuit diagram INPUT L, N: terminals input 90 ... 264 V AC 120 ... 375 V DC ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 317 -- CP-D range Applications Emergency lighting Communication Escalators Elevators LED lighting Venetian blind drives 318 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-D range Ordering details CP-D 12/0.83, CP-D 24/0.42 CP-D 12/2.1, CP-D 24/1.3 2CDC 271 024 F0007 2CDC 271 025 F0007 Description The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution panels. This range offers devices with output voltages of 12 V DC and 24 V DC at output currents of 0.42 A to 4.2 A. Thanks to their high thermal efficiency, these power supplies have very low power and heat dissipation and can be operated without forced cooling. All power supply units in the CP-D range are approved according to all relevant international standards. -- Ordering details Input voltage range 90-264 V AC/ 120-375 V DC Rated output voltage / current 12 V DC / 0.83 A Type CP-D 12/0.83 90-264 V AC/ 120-375 V DC 12 V DC / 2.1 A CP-D 12/2.1 90-264 V AC/ 120-375 V DC 24 V DC / 0.42 A CP-D 24/0.42 90-264 V AC/ 120-375 V DC 24 V DC / 1.3 A CP-D 24/1.3 90-264 V AC/ 120-375 V DC 24 V DC / 2.5 A CP-D 24/2.5 90-264 V AC/ 120-375 V DC 24 V DC / 4.2 A CP-D 24/4.2 Order code 1SVR427041R1000 1SVR427043R1200 1SVR427041R0000 1SVR427043R0100 1SVR427044R0200 1SVR427045R0400 Weight (1 pc.) kg (lb) 0.06 (0.13) 0.19 (0.41) 0.06 (0.13) 0.19 (0.41) 0.25 (0.56) 0.32 (0.71) 2CDC 271 028 F0007 CP-D 24/2.5 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 319 -- CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 12/0.83 Input circuit - supply circuit L, N Rated input voltage Uin Input voltage range 100-240 V AC 90-264 V AC / 120-375 V DC Frequency range AC 47-63 Hz Typical input current / typical power consumption at 115 V AC 200 mA / 12.68 W at 230 V AC 128.3 mA / 13.01 W Inrush current at 115 / 230 V AC 16 A / 32 A Power failure buffering time min. 30 ms Internal input fuse 1 A slow-acting / 250 V AC Power factor correction (PFC) no Indication of operational states Output voltage DC ON: green LED V: output voltage applied DC LOW: red LED V: output voltage too low Output circuit +, - Rated output voltage 12 V DC Tolerance of the output voltage ±1 % Adjustment range of the output voltage - Rated output power 10 W Rated output current Ir Ta m 60 °C 0.83 A Derating of the output current 60 °C < Ta m 70 °C 2.5 %/°C Maximum load change statical max. 1 % deviation with change of output voltage within the input voltage range max. 1 % CP-D 12/2.1 502 mA / 31.14 W 277 mA / 31.2 W 25 A / 50 A 2 A slow-acting / 250 V AC ++, -- 12-14 V DC 25 W 2.1 A Recover time TA Starting time after applying the supply voltage Rise time < 1 ms at Ir 1000 ms at rated load typ. 1 ms Residual ripple and switching peaks BW = 20 MHz 50 mV Parallel connection yes, using CP-D RU Series connection yes, to increase voltage Resistance to reverse feed 18 V / 1 s Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output hiccup-mode U/I characteristic curve Short-circuit protection continuous short-circuit stability Short-circuit behavior continuation with output power limiting Current limiting at short circuit typ. 1.4 A typ. 5.9 A Overload protection output power limiting Overvoltage protection 15-16.5 V DC No-load protection continuous no-load stability Starting of capacitive loads unlimited General data Efficiency typ. 78 % typ. 82 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class II 320 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 12/0.83 Electrical connection - Input circuit / Output circuit Connecting capacity fine-strand with wire end ferrule 0.2-1.5 mm2 (24-16 AWG) rigid 0.2-2.5 mm2 (26-12 AWG) Stripping length 4-5 mm (0.16-0.2 in) Tightening torque 0.6 Nm (5 lb.in) Environmental data Ambient temperature range operation -40...+70 °C (-40...+158 °F) rated load -40...+60 °C (-40...+131 °F) storage -40...+85 °C (-40...+185 °F) Altitude during operation IEC/EN 60068-2-13 max. 4850 m Damp heat (cyclic) (IEC/EN 60068-2-30) 4 x 24 cycles, 40 °C, 95 % RH Vibration (sinusoidal) (IEC/EN 60068-2-6) 50 m/s2, 10 Hz - 2 kHz Shock (half-sine) (IEC/EN 60068-2-27) 40 m/s2, 22 ms Isolation data Rated insulation voltage Ui Pollution degree input circuit / output circuit 3 kV AC 2 Overvoltage category ll Standards / Directives Standards IEC/EN 60950-1 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Protective low voltage SELV (IEC/EN 60950-1) Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 4 (4 kV / 8 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 level 4 (4 kV) surge IEC/EN 61000-4-5 level 3 (2 kV L-L) conducted disturbances, induced by radiofrequency fields IEC/EN 61000-4-6 level 3 (10 V) Interference emission high-frequency radiated high-frequency conducted IEC/EN 61000-6-3 class B class B CP-D 12/2.1 0.2-2.5 mm2 (24-14 AWG) 0.2-2.5 mm2 (24-12 AWG) 7 mm (0.28 in) 0.7 Nm (6 lb.in) level 4 (4 kV / 15 kV) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 321 -- CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 Input circuit - supply circuit L, N Rated input voltage Uin Input voltage range 100-240 V AC 90-264 V AC /120-375 V DC Frequency range AC 47-63 Hz Typical input current / typical power consumption at 115 V AC 184 mA / 11.62 W 600 mA / 37.92 W 1120 mA / 69.3 W 1800 mA / 117.3 W at 230 V AC 120.6 mA / 12 W 344 mA / 38.16 W 660 mA / 70.1 W 900 mA / 114.4 W Inrush current at 115 / 230 V AC max. 16 A / 32 A max. 25 A / 50 A max. 30 A / 60 A Power failure buffering time min. 30 ms min. 60 ms Internal input fuse 1 A slow-acting / 2 A slow-acting / 250 V AC 250 V AC 3.15 A slowacting / 250 V AC Power factor correction (PFC) Indication of operational states Output voltage Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current no DC ON: green LED V: output voltage applied DC LOW: red LED V: output voltage too low +, - 24 V DC ±1 % - 24-28 V DC 10 W 30 W Ta 60 °C: 0.42 A Ta 60 °C: 1.3 A 60 °C < Ta 70 °C: 60 °C < Ta 70 °C: 2.5 %/°C 2.5 %/°C ++, -- 60 W Ta 55 °C: 2.5 A 55 °C < Ta 70 °C: 2.5 %/°C 100 W Ta 60 °C: 4.2 A 60 °C < Ta 70 °C: 2.5 %/°C Maximum deviation with load change statical max. 1 % change of output voltage within the input voltage range max. 1 % Recover time TA Starting time after applying the supply voltage Rise time < 1 ms at Ir 1000 ms at rated load typ. 1 ms Residual ripple and switching peaks BW = 20 MHz 50 mV Parallel connection yes, using CP-D RU Series connection yes, to increase voltage Resistance to reverse feed 35 V / 1 s Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output hiccup-mode U/I characteristic curve Short-circuit protection continuous short-circuit stability Short-circuit behavior continuation with output power limiting Current limiting at short circuit typ. 0.78 A typ. 4.2 A typ. 6.05 A typ. 11.5 A Overload protection output power limiting Overvoltage protection 30-33 V DC No-load protection continuous no-load stability Starting of capacitive loads unlimited General data Efficiency typ. 80 % typ. 83 % typ. 86 % typ. 89 % Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class II 322 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-D range Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 Electrical connection - Input circuit / Output circuit Connecting capacity fine-strand with 0.2-1.5 mm2 wire end ferrule (24-16 AWG) 0.2-2.5 mm2 (24-14 AWG) rigid 0.2-2.5 mm2 (26-12 AWG) 0.2-2.5 mm2 (24-12 AWG) Stripping length Tightening torque Environmental data Ambient temperature range Altitude during operation Damp heat (cyclic) (IEC/EN 60068-2-30) Vibration (sinusoidal) (IEC/EN 60068-2-6) Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Protective low voltage Electromagnetic compatibility Interference immunity to electrostatic discharge 4-5 mm (0.16-0.2 in) 0.6 Nm (5 lb.in) operation -40...+70 °C rated load -40...+60 °C storage -40...+85 °C IEC/EN 60068-2-13 max. 4850 m 4 x 24 cycles, 40 °C, 95 % RH 50 m/s2, 10 Hz - 2 kHz 40 m/s2, 22 ms input circuit / output circuit 3 kV AC 2 ll IEC/EN 60950-1 2014/35/EU 2014/30/EU 2011/65/EU SELV (IEC/EN 60950-1) IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4 (4 kV / 8 kV) level 4 (4 kV / 15 kV) 7 mm (0.28 in) 0.7 Nm (6 lb.in) -40...+55 °C 4 kV AC radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields IEC/EN 61000-4-3 level 3 (10 V/m) IEC/EN 61000-4-4 level 4 (4 kV) IEC/EN 61000-4-5 level 3 (2 kV L-L) IEC/EN 61000-4-6 level 3 (10 V) Interference emission high-frequency radiated high-frequency conducted IEC/EN 61000-6-3 class B class B CP-D 24/4.2 -40...+60 °C 3 kV AC level 4 (4 kV / 8 kV) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 323 -- CP-D range Technical diagrams 22CCDDCC27227202002F002F007207 22CCDDCC22727202022F20F2007207 -- Characteristic curve of output at Ta = 25 °C Uout [V] 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0.25 0.5 0.75 1 CP-D 12/0.83 1.25 Iout [A] 22CCDDCC22772201091F90F2007207 Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0 0.125 0.25 CP-D 24/0.42 0.375 0.5 0.625 0.75 0.875 Iout [A] 22CCDDCC 227722002121F0F2002707 Uout [V] 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0.5 1 1.5 2 2.5 3 3.5 4 Iout [A] CP-D 12/2.1 Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0 0.5 1 CP-D 24/1.3 1.5 2 2.5 3 Iout [A] Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0 0.5 1 1.5 2 2.5 3 3.5 4 CP-D 24/2.5 Iout [A] 22CCDCC22772202032F30F2007207 Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0 0 1 2 3 45 678 CP-D 24/4.2 Iout [A] -- Characteristic curve of temperature at rated output voltage Pout [%] Pout [%] 100 90 80 70 60 50 40 30 20 10 -10 0 10 20 30 40 50 60 70 Ta [°C] CP-D except CP-D 24/2.5 2CDC 272 018 F0207 2CDC 272 018 F0207 100 90 80 70 60 50 40 30 20 10 -10 0 10 20 30 40 50 60 70 Ta [°C] CP-D 24/2.5 2CDC22C72D 0C1287F20200178 F0207 22CCDDCC22772203003F00F2007207 324 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-D range Technical diagrams -- Dimensional drawings Dimensions in mm 18.0 [0.71"] 67.0 [2.64"] 44.5 [1.75"] 53.0 [2.09"] 67.0 [2.64"] 44.5 [1.75"] 32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"] 22CCDDCC27227021201F20bF007b07 32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"] 22CCDCD 2C72207121 F001b107F0b07 91.0 [3.58"] 91.0 [3.58"] CP-D 12/0.83, CP-D 24/0.42 71.0 [2.80"] 67.0 [2.64"] 44.5 [1.75"] 91.0 [3.58"] CP-D 24/2.5 32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"] 22CCDDCC227722001133FF00bb0077 91.0 [3.58"] CP-D 12/2.1, CP-D 24/1.3 89.9 [3.54"] 67.0 [2.64"] 44.5 [1.75"] CP-D 24/4.2 32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"] 22CCDDCC 2272 014 F0b077 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 325 326 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 327 -- CP-B range Table of contents 328 Benefits and advantages 330 Operation controls 331 Applications 332 Ordering details 333 Technical data 336 Technical diagrams 328 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-B range Benefits and advantages ABB's ultra-capacitor based CP-B buffer modules serve to ensure a short-term uninterrupted power supply system with a voltage of 24 V DC by buffering the load in case of power loss. The buffer modules feature a technology for storing energy: the use of ultracapacitors obviates the need for maintenance and exempts deep discharge in comparison to batteries. Energy storage can be expanded with additional extension modules for longer buffering times and is therefore extremely adaptable. 24 7 Continuous operation · Buffering 24 V DC supply of up to 380 s · Maintenance-free, ultra-capacitor technology · Temperature resistant · No deep charge · Small footprint ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 329 -- CP-B range Benefits and advantages Power supply systems have to be highly reliable in most areas of energy management and automation technology. Often, batteries are used for supporting the supply system in case of mains failures. Batteries have limited lifetimes depending on environmental parameters and have to be maintained regularly, which causes extra work and costs. Using the ultra-capacitor technology, ABB offers an innovative and completely maintenance-free new product for buffering the 24 V DC supply in case of interrupted mains on the primary side of the switch mode power supply. The CP-B range is an ultra-capacitor buffer energy storage system for power supply units which ensures a short term uninterrupted power supply system. In case of power loss, the energy stored in the capacitor guarantees that the load is continually provided for up to several hundred seconds depending on the load current. Characteristics · 3 buffer modules for buffering 24 V DC: CP-B 24/3.0 (3 A / 1 kWs1)) CP-B 24/10.0 (10 A / 10 kWs1)) CP-B 24/20.0 (20 A / 8 kWs1)) · CP-B 24/3.0 and CP-B 24/20.0 expandable with additional extension module(s) CP-B EXT.2 (2 kWs1)) · LEDs for status indication · Relay contacts for status messaging · Very high backup times (e.g. with CP-B 24/10.0 up to 8 minutes at 1 A load current) · Short charging times · High efficiency, higher than 90 % · Wide temperature range · DIN rail mountable, compact housing · Extended temperature range -40...60 °C 1) internal energy buffer Order code Rated input voltage Rated current Energy storage (min.) Typical charging time at load current Typical buffering time1) at load current CP-B 24/3.0 1SVR427060R0300 24 V DC 3 A DC 1.000 Ws 100 % 65 s 0 % 56 s 100 % 13 s 50 % 28 s 25 % 66 s 10 % 148 s energy storage x 0.9 1) buffering time current x output voltage CP-B 24/10.0 1SVR427060R1000 24 V DC 10 A DC 10.000 Ws 134 s 82 s 38 s 76 s 140 s 380 s CP-B 24/20.0 1SVR427060R2000 24 V DC 20 A DC 8.000 Ws 135 s 62 s 15 s 30 s 60 s 150 s CP-B EXT.2 1SVR427065R0000 3 A DC 2.000 Ws 330 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-B range Operation controls Input terminals SHUT-DOWN+, SHUT-DOWN-: Input signal terminals INPUT OK, BUFFER STATUS, FAILURE: Signalling contact terminals L+IN, L-IN: Input voltage terminals Indication of operational states OPERATION: Buffer module in operation (standby or buffering) INPUT OK: Input voltage applied Output terminals L+OUT, L-OUT, L-OUT: Output voltage terminals ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 331 -- CP-B range Applications -- Example of application L N max. 20 A L+ L- CP-B 24/10.0 CP-C.1 24/20.0 L+IN L-IN L+OUT L-OUT max. 10 A L+ buffered L- load 1 ... load n L+ unbuffered L- load 1 ... load n 332 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-B range Ordering details CP-B 24/3.0 CP-B 24/10.0 2CDC 271 002 S0010 2CDC 271 001 S0010 Description Ultra capacitor based buffer units of the CP-B range offer the highest reliability also in harsh environments. Thanks to their ultra-cap based technology, the units are maintenance free, there will be no deep discharge and these products offer a very wide operational ambient temperature range. CP-B range buffer units are an excellent solution for avoiding voltage drops in solar applications, for example. -- Ordering details Rated input voltage 24 V DC Rated current 3 A DC 10 A DC 20 A DC Type Order code CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 1SVR427060R0300 1SVR427060R1000 1SVR427060R2000 Weight (1 pc.) kg (lb) 0.59 (1.31) 2.10 (4.63) 2.20 (4.85) -- Ordering details - Extension unit for CP-B 24/3.0 and CP-B 24/20.0 Rated voltage Voltage range Type Order code 24 V DC 0-26.4 V DC CP-B EXT.2 1SVR427065R0000 Weight (1 pc.) kg (lb) 1.04 (2.30) 2CDC 271 003 S0010 CP-B 24/20.0 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 333 -- CP-B range Technical data Type Input circuit - Supply circuit Rated input voltage Uin Input voltage range Minimum charging potential Rated input current Inrush current limiting Transient overvoltage protection CP-B 24/3.0 L+IN L-IN 24 V DC 23.7-26.4 V DC 23.7 V DC 3 A DC 50 A / 1 ms suppressor diode CP-B 24/10.0 23.9-27 V DC 23.9 V DC 10 A DC 35 A / 2 ms varistor / suppressor diode Internal input fuse (apparatus protection, not accessible) 4 A slow acting 15 A (FK2) Internal fuse capacitors circuit (not accessible) 25 A (FK2) Kind of input SHUT-DOWN - control input rated voltage - 24 V DC voltage range - 6-45 V DC Output circuit L+OUT L-OUT L-OUT Rated output power 69 W 240 W Rated output voltage Uout Output voltage (buffer mode) 24 V DC 23.0 V DC 23.2 V DC Tolerance of the output voltage +2...-10 % Rated output current Ir Peak output current (fully loaded capacitors required) Ta 60 °C 3 A DC Ta 60 °C 6 A DC (min. 1.5 s) 10 A DC 20 A DC (10 A power supply + 10 A CP-B, min. 1.5 s) Control of limiting current - 10.3 A DC w0.1A Shut-down if limiting current is exceeded - after 1.5 s Short-circuit protection (only via external fuse) no continuous short-circuit stability Internal output fuse (not accessible) - 15 A (FK2) Required external fuse 3.15 A slow acting 10 A slow acting Current limiting at output circuit Breaking capacity of output circuit t= 2.5 ms - 1.05...1.2 x Ir 24 V DC, 10 A Power failure buffering time 1) load-dependent, min. load-dependent, min. 13 s at 100 % load 38 s at 100 % load Overload protection thermal protection Kind of output INPUT OK n/o contact BUFFER STATUS - n/o contact FAILURE - c/o contact Contact material Ag + Au-clad Minimum switching voltage / Minimum switching current 5 V DC / 1 mA Maximum switching voltage / Maximum switching current 50 V AC / 1.0 A, 30 V DC / 0.5 A Mechanical lifetime 5 x 106 switching cycles Electrical lifetime 0.1 x 106 switching cycles Maximum fuse rating to achieve short-circuit protection n/o or n/c 1.0 A AC / 0.5 A DC contact CP-B 24/20.0 23.4-29 V DC 23.4 V DC 20 A DC 35 A / 2 ms varistor / suppressor diode 30 A (FK2) control input 24 V DC 6-45 V DC 480 W 23.2 V DC 20 A DC 40 A DC (min. 1.5 s) - 25 A slow acting load-dependent, min. 15 s at 100 % load 334 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-B range Technical data Type CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 General data Maximum internal power consumption 7 W 20 W 40 W Power consumption with unloaded output 0.75 W 3 W 1.6 W Energy storage (min.) 1000 Ws 10000 Ws 8000 Ws Typical charging time at load current 100 % 65 s 134 s 135 s 0 % 56 s 82 s 62 s Typical buffering time at load current1) 100 % 13 s 38 s 15 s 50 % 28 s 76 s 30 s 25 % 66 s 140 s 60 s 10 % 148 s 380 s 150 s Efficiency > 90 % Dimensions see "Dimensional drawings" Material cover / housing shell steel sheet powdered Mounting DIN rail (IEC/EN 60715), snap-on mounting Mounting position horizontal Minimum distance to other units horizontal not necessary vertical 40 mm (1.58 in) 80 mm (3.15 in) Pollution degree 2 Degree of protection housing / terminal IP20 Protection class (IEC/EN 61140) III SELV / PELV (condition: power supply fulfills class III) Electrical connection - Input circuit / Output circuit pull spring terminals pull spring terminals pluggable screw type terminals Connecting capacity fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) 0.08-1.5 mm² (28-18 AWG) 0.2-4.0 mm² (24-12 AWG) rigid 0.08-1.5 mm² (28-16 AWG) 0.08-4.0 mm² (28-16 AWG) 0.2-6.0 mm² (24-10 AWG) Stripping length Signaling circuit Connecting capacity 6.0 mm (0.24 in) fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) 7.0 mm (0.28 in) 0.14-1.0 mm² (26-16 AWG) rigid 0.08-1.5 mm² (28-16 AWG) 0.14-1.5 mm² (28-16 AWG) Stripping length Environmental data Ambient temperature Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radio-frequency fields 6.0 mm (0.24 in) 7.0 mm (0.28 in) operation -40...+60 °C storage -40...+60 °C EN 50178, IEC/EN 60950-1, IEC/EN 62040-2 2014/35/EU 2014/30/EU 2011/65/EC IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 3, 6 kV / 8 kV IEC/EN 61000-4-3 level 3, 10 V/m (27-1000 MHz) / level 2, 3 V/m (1400-2700 MHz) IEC/EN 61000-4-4 level 3, 2(1) kV / 5 kHz IEC/EN 61000-4-5 level 1, 0.5 kV IEC/EN 61000-4-6 level 3, 10 V (150 kHz-80 MHz) voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 buffered by ultra-capacitors Interference emission high-frequency radiated high-frequency conducted EN 61000-6-4 DIN EN 55011 B/C1 DIN EN 55011 B/C1 energy storage x 0.9 1) buffering time current x output voltage ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 335 -- CP-B range Technical data Data at Ta = 25 °C and rated values, unless otherwise indicated Type CP-B EXT 2.0 Extension circuit EXT+ EXT+ EXT- EXT- Rated voltage 24 V DC Voltage range 0-26.4 V DC Rated current 3 A DC Internal input fuse (apparatus protection, not accessible) 4 A slow acting (PTC) Short-circuit protection via internal 3 A fuse Overload protection only in combination with CP-B 24/3.0 or CP-B 24/20.0 Indication of operational states status information and fault messages of the buffer module apply General data Power consumption without load 0.5 W Energy storage (min.) 2000 Ws Material cover / housing shell steel sheet powdered Mounting DIN rail (IEC/EN 60715), snap-on mounting Mounting position horizontal Minimum distance to other units horizontal not necessary vertical 40 mm (1.58 in) Pollution degree 2 Degree of protection housing / terminal IP20 Protection class (IEC/EN 61140) III SELV / PELV (condition: power supply fulfills class III) Electrical connection - Extension circuit pull spring terminals Connecting capacity fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG) rigid 0.08-1.5 mm² (28-16 AWG) Stripping length 6.0 mm (0.24 in) Environmental data Ambient temperature operation -40...+60 °C storage -40...+60 °C Vibration, sinusoidal IEC/EN 60068-2-6 1.5 mm, 3-57.55 Hz; 2 g, 57.55-500 Hz, 10 cycles Shock, half-sine IEC/EN 60068-2-27 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face Standards / Directives Standards EN 50178, IEC/EN 60950-1, IEC/EN 62040-2 Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 3, 6 kV / 8 kV radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3, 10 V/m (27-1000 MHz) / level 2, 3 V/m (1400-2700 MHz) electrical fast transient/burst IEC/EN 61000-4-4 level 3, 2(1) kV / 5 kHz surge IEC/EN 61000-4-5 level 1, 0.5 kV conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 level 3, 10 V (150 kHz-80 MHz) voltage dips, short interruptions and voltage variations IEC/EN 61000-4-11 buffered by ultra-capacitors Interference emission EN 61000-6-4 high-frequency radiated DIN EN 55011 B/C1 high-frequency conducted DIN EN 55011 B/C1 336 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- CP-B range Technical diagrams 2CDC 272 031 F0210 -- Characteristic curve of the temperature at rated load Iout [A] A 3.0 B 1.5 -40 0 CP-B 24/3.0 Iout [A] 20 40 60 10.0 7.5 5.0 Ta [°C] A B 2CDC 272 028 F0210 Years -- Capacitors life span over temperature 60 50 40 30 20 10 0 10 20 30 40 50 60 70 Temperature [°C] 2CDC 272 029 F0210 -40 0 CP-B 24/10.0 Iout [A] 20 40 60 20 15 10 Ta [°C] A B -40 -20 0 20 40 60 CP-B 24/20.0 Ta [°C] A Normal application (up to 50 % buffer mode, 5 charging and discharging cycles in direct series) B Continuous charging and discharging in direct series. As this is not typical of a real application, this should be considered as theoretical indication 2CDC 272 030 F0210 2CDC 272 010 F0017 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 337 -- CP-B range Technical diagrams -- Dimensional drawings Dimensions in mm, inches IEC/EN 60715 TH 35-7.5 TH 35-15 IEC/EN 60715 TH 35-7.5 TH 35-15 92.5 3.64" 99.8 3.93" 92.5 3.64" 99.8 3.93" 2CDC 272 007 F0017 112.4 4.43" 121.2 4.77" 126.2 4.97" CP-B 24/3.0 60.0 2.36" 112.4 4.43" 121.2 4.77" 126.2 4.97" CP-B EXT.2 60.0 2.36" IEC/EN 60715 TH 35-7.5 TH 35-15 163.0 6.42" 167.9 6.61" 2CDC 272 008 F0017 CP-B 24/10.0 137.8 5.43" 145.3 5.72" 151.0 5.95" 115.6 4.55" IEC/EN 60715 TH 35-7.5 TH 35-15 192.5 7.58" 198.0 7.80" 2CDC 272 009 F0017 CP-B 24/20.0 187.8 7.4" 195.3 7.7" 215.8 8.5" 83.7 3.3" 338 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 339 -- Redundancy units Table of contents 341 Benefits and advantages 342 Ordering details 343 Technical data 347 Technical diagrams 340 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- --Establish true redundancy Rwehdeurenditarnecaylluynmitastters with BAeBnBe'sfiptsoawnedr asduvpapnltyages redundancy units. ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 341 -- Redundancy units Benefits and advantages ABB's redundancy units are used to establish true redundancy, which increases the availability of electrical systems significantly. Three versions are available with different output currents and power supply housings: · CP-D RU in MDRC housing · CP-RUD for a true redundant setup of two 24 V DC power supplies with a max. output current of 2.5 A per channel · CP-C.1-A-RU for a true redundant setup of two 24 V DC power supplies of the CP range 24 7 Continuous operation Highest system reliability · Redundancy setup of the application possible to allow parallel operation · Long lifetime 342 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Redundancy units Ordering details CP-C.1-A-RU CP-C.1-A-RU-L CP-D RU 2CDC 271 010 F0006 2CDC271001V0019 2CDC271001V0018 Description Whenever the highest availability and reliability are key requirements, a true redundancy setup with two power supplies connected to a redundancy unit is the best solution. In case one power supply fails, the other one keeps supplying the load. Furthermore, even a short circuit in one power supply will not affect the other one, which keeps supplying the load. The CP-C.1-A-RU is also available with coated PCBA (CP-C.1-A-RU-C) for harsh environments. -- Ordering details - CP-C.1-A-RU for decoupling of CP power supplies up to 20 A per input / channel Input voltage range Rated input current per channel Rated output voltage / current Type Order code 10 - 28.5 V DC 20 A 24 V DC / 2 x 20 A or 1 x 40 A uncoated CP-C.1-A-RU 1SVR360060R1001 coated CP-C.1-A-RU-C 1SVR360060R2001 uncoated CP-C.1-A-RU-L 1SVR361060R1001 Weight (1 pc.) kg (lb) 1.04 (2.29) 1.04 (2.29) 1.04 (2.29) -- Ordering details - CP-D RU for decoupling of two CPD power supply units Input voltage Rated input Rated output voltage / Type range current current Order code 9-35 V DC 2 x 5 A 24 V DC / 1 x 10 A CP-D RU 1SVR427049R0000 Weight (1 pc.) kg (lb) 0.075 (0.165) -- Ordering details - CP-RUD for decoupling of two CPE power supply units 35 V and < 5 A Input voltage Rated input Rated output voltage / Type range current current 5-35 V DC 0.5 - 2.5 A 24 V DC / 5 A CP-RUD Order code 1SVR423418R9000 Weight (1 pc.) kg (lb) 0.088 (0.195) 2CDC 271 006 F0003 CP-RUD ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 343 -- Redundancy units Technical data Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated Type CP-C.1-A-RU, CP-C.1-A-RU-L CP-C.1-A-RU-C Input circuit - Supply circuit (+/+, -/-) Rated input voltage Uin Input voltage range 24 V DC 10-28.5 V DC Rated input current Iin per channel Maximum input current per channel Transient overvoltage protection -25 °C m Ta m 60 °C -25 °C m Ta m 40 °C -40 °C m Ta m 40 °C 20 A 30 A yes, varistor 30 A Output circuit (++/--) Rated output voltage Uout Voltage drop input/output 24 V DC typ. 0.6 V, max. 0.9 V Rated output current Ir Max. output current (Power reserve) Derating of the output current Resistance to reverse feed -25 °C m Ta m 60 °C 2 x 20 A or 1 x 40 A -25 °C m Ta m 40 °C 2 x 30 A or 1 x 60 A -40 °C m Ta m 40 °C - 2 x 30 A or 1 x 60 A 60 °C < Ta m 70 °C 2.5 % per Kelvin temperature increase < 60 V General data Power loss input 2 x 20 A 23.0 W input 2 x 10 A 9.4 W input 2 x 5 A 4.1 W MTBF acc. to MIL 217 HDBK on request Dimensions see "Dimensional drawings" Material of housing cover / housing shell / front aluminium / zinc-coated sheet steel / plastic Mounting DIN rail (IEC/EN 60715), snap-on mounting Mounting position 1 and 7 Minimum distance to other units horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in) Degree of protection (IEC/EN 60529) housing / terminals IP20 / IP20 Protection class (IEC/EN 61140) III Electrical connection - Input circuit / Output circuit Connecting capacity fine-strand with(out) wire end ferrule 2.5-10 mm2 (12-8 AWG) rigid 2.5-16 mm2 (12-6 AWG) Stripping length 10 mm (0.39 in) Tightening torque 1.2 Nm (10.5 lb.in) Recommended screw driver PH1 / Ø 4.0 x 0.8 mm (0.16 x 0.03 in) 344 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Redundancy units Technical data Type Environmental data Ambient temperature range Climatic class (IEC/EN 60721-3-1) Climatic class (IEC/EN 60721-3-2) Climatic class (IEC/EN 60721-3-3) CP-C.1-A-RU, CP-C.1-A-RU-L CP-C.1-A-RU-C operation -25...+70 °C (-13... +158 °F) rated load -25...+60 °C (-13... +140 °F) storage -40...+85 °C (-40...+185 °F) transportation -40...+85 °C (-40...+185 °F) storage 1K2 (-40...+85 °C / -40...+185 °F) transportation 2K2 (-40...+85 °C / -40...+185 °F) operation 3K3 (-25...+70 °C / -13...+158 °F) -40...+70 °C (-40...+158 °F) -40...+60 °C (-40...+140 °F) 3K3 (-40...+70 °C / -40...+158 °F) Damp heat, cyclic (IEC/EN 60068230) Vibration (IEC/EN 6006826) test Db: 55 °C, 2 cycles test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis Shock, halfsine (IEC/EN 60068227) test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis Coated PCBA no yes Gaseous corrosive environment withstand test (IEC/EN 60068-2-60) - testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S 100 ± 10 ppb - SO2/SO3 300 ± 20 ppb - Cl2 100 ± 10 ppb - NOx 1250 ± 20 ppb Isolation data Rated impulse withstand voltage Uimp (EN 50178) input / housing 1.5 kV (1.2/50 µs) output / housing 1.5 kV (1.2/50 µs) Pollution degree 2 Standards / Directives Standards IEC/EN 61204 EMC Directive 2014/30/EU ATEX Directive - 2014/34/EU RoHS Directive 2011/65/EU Electrical safety IEC/EN 60950-1 Industrial control equipment / General Use Power Supplies UL 508 / CSA 22.2 No 107.1 Electromagnetic compatibility Interference immunity to electrostatic discharge IEC/EN 61000-4-2 Level 4, contact discharge ±8 kV, air discharge ±15 kV (criterion B) electrical fast transient / burst IEC/EN 61000-4-4 Level 3, DC mains inputs and output ±2 kV (criterion B) surge IEC/EN 61000-4-5 Level 1, DC mains inputs and output ±0.5 kV, input and output vs. PE ±1 kV (criterion B) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 345 -- Redundancy units Technical data Type CP-D RU Input circuit - Supply circuit IN 1 + + -, IN 2 + + - Rated input voltage Uin Input voltage range 24 V DC 9-35 V DC Rated input current Iin per channel Maximum input current per channel 5 A 10 A for 300 s Transient overvoltage protection no Output circuit OUT + + +, - - - Rated output voltage Uout Voltage drop 24 V DC typ. 0.5 V Rated output current Iout Resistance to reverse feed 10 A < 35 V General data MTBF on request Duty cycle 100 % Dimensions see "Dimensional drawings" Material of housing plastic Mounting DIN rail, snap-on mounting without any tool Mounting position 1, 7 Minimum distance to other units horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in) Electrical connection - Input circuit / Output circuit Connecting capacity fine-strand with (out)wire end ferrule 0.2-2.5 mm2 (24-14 AWG) rigid 0.2-2.5 mm2 (24-12 AWG) Stripping length 7.0 mm (0.28 in) Tightening torque 0.67 Nm (6 Ib.in) Environmental data Ambient temperature range operation -40...+70 °C storage -40...+85 °C Relative humidity RH at 40 °C 20-95 %, no condensation Vibration (IEC/EN 60068-2-6) mounting by rail: 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min for each axis Shock (IEC/EN 60068-2-27) Standards / Directives Standards RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst conducted disturbances, induced by radio-frequency fields Interference emission high-frequency radiated high-frequency conducted 15 G, 11 ms, 3 axis, 6 faces, 3 times for each face IEC/EN 61204-3, IEC/EN 60950-1 2011/65/EU EN 55024 IEC/EN 61000-4-2 level 3, air discharge 8 kV, contact discharge 4 kV IEC/EN 61000-4-3 level 3, 10 V/m IEC/EN 61000-4-4 level 3, 2 kV / 5 kHz IEC/EN 61000-4-6 level 3, 10 V EN 55022 IEC/CISPR 22 / EN 55022 class B IEC/CISPR 22 / EN 55022 class B 346 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Redundancy units Technical data Type CP-RUD Input circuit - Supply circuit A: U1+/-U ; B: U2+/-U Rated input voltage Uin Input voltage range 24 V DC 5-35 V DC Rated input current Iin per channel Maximum input current per channel 0.5-2.5 A 10 A for 300 s Transient overvoltage protection no Output circuit L+, L+, L+, L-, L-, L- Rated output voltage Uout Voltage drop 24 V DC typ. 0.6 V, max. 0.7 V Rated output current Iout Peak output current 0.5-5 A 20 A for 150 s Resistance to reverse feed < 35 V General data Dimensions see "Dimensional drawings" Minimum distance to other units horizontal / vertical 10 mm / 10 mm (0.39 in / 0.39 in) Degree of protection housing / terminals IP20 / IP20 Material of housing housing shell / cover plastic / plastic Protection class - Mounting DIN rail (IEC/EN 60715) Mounting position horizontal Electrical connection - Input circuit / Output circuit Connecting capacity fine-strand with wire end ferrule 2 x 0.75-2.5 mm2 (2 x 18-14 AWG) fine-strand without wire end ferrule rigid 2 x 0.5-4 mm2 (2 x 20-12 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.6-0.8 Nm Environmental data Ambient temperature range operation -20...+60 °C rated load -20...+60 °C storage -40...+85 °C Damp heat (IEC/EN 60068-2-3) 93 % at 40 °C, no condensation Isolation data Insulation voltage input / output / housing - Pollution degree (EN 50178) 2 Standards / Directives Electrical safety EN 50178 RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 level 3 (air discharge ±8 kV, contact discharge ±6 kV) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m) electrical fast transient/burst IEC/EN 61000-4-4 level 3 (w2 kV) surge conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-5 level 1 (w0.5 kV) IEC/EN 61000-4-6 level 3 (10 V) Interference emission high-frequency radiated high-frequency conducted IEC/EN 61000-6-3 class B class B ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 347 -- Redundancy units Technical diagrams -- Dimensional drawings Dimensions in mm, inches 129.8 5.11" 126.8 4.99" 56.4 2.22" INPUT 1 + - INPUT 2 + - IEC/EN 60715 TH 35-7.5 TH 35-15 CP-C.1-A-RU 136.0 5.35" CP-C.1-A-RU, CP-C.1-A-RU-L CP-C.1-A-RU-C 109.5 4.31" 102 4.02" + + - - OUTPUT 22.5 .886" 129.4 5.09" 2CDC272011F0017 91.0 3.58" 35.0 1.38" + + + + - - IN1 IN2 IN1 IN2 +++ - - O U T CP-D RU 67.0 2.64" 44.5 1.75" 32.1 1.26" 49.0 1.93" 57.5 2.26" 2CDC272033F0010 78 3.07" 2CDC252188F0B05 CP-RUD 100 3.94" 348 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 349 -- Electronic protection devices EPD24 Table of contents 350 Benefits and advantages 351 Applications 352 Ordering details 353 Operating data 354 Technical data 355 Technical information 356 Technical diagrams 357 Approvals, Safety instructions 358 Installation guidelines 350 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Electronic protection devices EPD24 Benefits and advantages With its narrow width of only 12.5 mm, EPD24 can fit everywhere it can even be mounted side-by-side. Its adjustable and fixed current ratings, projectable protection through current limitation as well as a single trip curve for all types of loads allow for use in a wide field of applications. 24 7 Continuous operation Highlights · Safety and reliability · Operational continuity · Worldwide use thanks to relevant certifications · Compact and effective ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 351 -- Electronic protection devices EPD24 Applications Features · Selective load protection, one electronic tripping characteristic. · Active current limitation for safe connection of capacitive loads up to 20,000 µF and on overload/short circuit · Current ratings 0.5...12 A · Reliable overload disconnection with 1.1 x IN · Manual ON/OFF button · Clear status and failure indication through LED and integrated auxiliary contact · Integral fail-safe element adjusted to current rating · Width per unit only 12.5 mm · Rail mounting · Ease of wiring through busbar LINE+ and 0 V as well as signal bars · UL- and CSA-approvals allow international use of the devices Applications · Packaging machines · Automation · Automation & Process Control · Automotive Manufacturing · Chemical, Oil & Gas · Medical Equipment · Pharmaceutical & Food · Power Engineering DC 24 V · Renewable Energy · Steel Production 352 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Electronic protection devices EPD24 Ordering details EPD24-TB-101-3A 2CDC 051 001 S0010 Description The protection devices EPD24 extend the ABB product range of modular DIN rail components by electronic overcurrent protection modules for selective protection of 24 V DC load circuits. This protection is achieved by a combination of active electronic current limitation in the case of a short circuit and an overload deactivation from 1.1 x In upwards. If a fault occurs in a load circuit, the protection device EPD24 will detect this rapidly and reliably, then disable the power output transistor and hence interrupt the current flow in the defective circuit. The maximum possible overcurrent is always limited to 1.3...1.8 times the selected rated current. An activation of capacitive loads up to 20,000 F is possible, deactivation only occurring in the case of overloads or short circuits. Selective deactivation of the defective current circuit means undefined error states and a complete system stop are prevented. -- Ordering details Rated current IN bbn 40 16779 EAN A 0.5 829960 1 829984 2 830003 3 830027 4 830041 6 830065 8 830089 10 830102 12 830126 Type Order code EPD24-TB-101-0.5A 2CDE601101R2905 EPD24-TB-101-1A 2CDE601101R2001 EPD24-TB-101-2A 2CDE601101R2002 EPD24-TB-101-3A 2CDE601101R2003 EPD24-TB-101-4A 2CDE601101R2004 EPD24-TB-101-6A 2CDE601101R2006 EPD24-TB-101-8A 2CDE601101R2008 EPD24-TB-101-10A 2CDE601101R2010 EPD24-TB-101-12A 2CDE601101R2012 Pkg Weight qty (1 pc.) kg (lb) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) 4 0.065 (1.433) Description bbn 40 Type 16779 EAN Busbars for LINE+ and 0 V, grey 830140 insulation, length 500 mm 1) Signal bars for aux. contacts, 830164 grey insulation, length 21 mm EPD-BB500 EPD-SB21 1) Max. load with one line entry Imax = 50 A (recommended: mid line entry) Max. load with two line entries Imax = 63 A Order code 2CDE605100R0500 2CDE605200R0021 Pkg Weight qty (1 pc.) kg (lb) 10 0.2 (0.441) 10 0.4 (0.882) ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 353 -- Electronic protection devices EPD24 Operating data Operating data Operating voltage UB Current rating IN Closed current I0 Status indication by means of Load circuit Load output Overload disconnection Short-circuit current IK Trip time For electronic disconnection Temperature disconnection Low voltage monitoring load output Starting delay tStart Disconnection of load circuit Free-wheeling circuit Several load outputs must not be connected in parallel Signal output Electrical data ON condition LED green OFF condition LED off Fault condition LED orange Fault condition LED red Aux. contact Fault 24 V DC (18...32 V) fixed current ratings: 0.5, 1, 2, 3, 4, 6, 8, 10, 12 A ON condition: typically 20...30 mA depending on signal output Green: unit is ON load circuit / Power-MOSFET is switched on Orange: in the event of overload or short circuit until electronic disconnection Red: unit electronically disconnected load circuit/Power-MOSFET OFF undervoltage (UB < 8 V) after switch-on till the end of the delay period OFF: manually switched off or device is dead potential-free auxiliary contact F ON/OFF/ condition of switch Power-MOSFET switching output (high slide switch) typically 1.1 x IN (1.05...1.35 x IN) active current limitation see time/current characteristics typically 3 s at ILoad > 1.1 x IN typically 100 ms...3 s at ILoad > 1.8 x IN (or 1.5 x IN/1.3 x IN, ) internal temperature monitoring with electronic disconnection with hysteresis, no reset required: load »OFF« at UB< 8 V typically 0.5 sec after every switch-on and after applying UB electronic disconnection suitable external free-wheeling circuit to be used with inductive load potential-free auxiliary contact max. 30 V DC/0.5 A, min. 10 V DC/10 mA voltage UB applied, switch is in ON position no overload, no short circuit device switched off (switch is in OFF position) no voltage UB applied overload condition > 1.1 x IN up to electronic disconnection electronic disconnection upon overload or short circuit Device switched off with control signal (switch is in ON position) single signal, make contact contact open, terminal 13-14 signal output fault conditions no operating voltage UB ON/OFF switch is in OFF position red LED lighted (electronic disconnection) 354 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Electronic protection devices EPD24 Technical data General data Fail-Safe element Housing material Mounting Ambient temperature Storage temperature Humidity Vibration Degree of protection EMC (EMC directive, CE logo) Isolations coordination (IEC 60934) Dielectric strength Isolation resistance (OFF condition) Approvals/Declarations of conformity Dimensions (B x H x T) Weight Terminals Screw terminals Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve Multi-lead connection (2 identical cables) rigid/flexible Flexible with wire end ferrule without plastic sleeve Flexible with TWIN wire end ferrule with plastic sleeve Wire stripping length Tightening torque (EN 60934) Terminals Screw terminals Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve Wire stripping length Tightening torque (EN 60934) backup fuse for EPD24 not required because of the integral redundant fail-safe element moulded symmetrical rail to EN 50022-35x7.5 0...+50 °C (without condensation, see EN 60204-1) -20...+70 °C 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721 3 g, test to IEC 60068-2-6 test Fc housing: IP20 DIN 40050 terminals: IP20 DIN 40050 emission: EN 61000-6-3 susceptibility: EN 61000-6-2 0.5 kV/pollution degree 2 reinforced insulation in operating area max. 32 V DC (load circuit) n/a, only electronic disconnection UL 2367 Solid State Overcurrent Protectors UL 1604, (class I, division 2, groups A, B, C, D) UL 508 CSA C22.2 No. 213 (class I, division 2) CSA C22.2 No. 142 CE logo 12.5 x 80 x 83 mm approx. 65 g Line+/LOAD+/0V M4 0.5 10 mm2 0.5 4 mm2 0.5 2.5 mm2 0.5 6 mm2 10 mm 1.5 1.8 Nm aux. contacts M3 0.25 - 2.5 mm2 8 mm 0.5 Nm Table 1: voltage drop, current limitation, max. load current current rating typically voltage drop active current IN UON at IN limitation (typically) 0.5 A 1 A 2 A 3 A 4 A 6 A 8 A 10 A 12 A 70 mV 80 mV 130 mV 80 mV 100 mV 130 mV 120 mV 150 mV 180 mV 1.8 x IN 1.8 x IN 1.8 x IN 1.8 x IN 1.8 x IN 1.8 x IN 1.5 x IN 1.5 x IN 1.3 x IN max. load current at 100 % ON duty Tambient = 40 °C Tambient = 40 °C 0.5 A 0.5 A 1 A 1 A 2 A 2 A 3 A 3 A 4 A 4 A 6 A 5 A 8 A 7 A 10 A 9 A 12 A 10.8 A Attention: when mounted side-by-side without convection, the ERD24 should carry no more than 80 % of its rated load with 100 % ON duty due to thermal effects. ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 355 -- Electronic protection devices EPD24 Technical information Time/Current characteristic curve (Tambient = 25 °C) The trip time is typically 3 s in the range between 1.1 and 1.8 x I 1) N. Electronic current limitation occurs at typically 1.8 x IN1) which means that under all overload conditions (independent of the power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x IN1) times the current rating. Trip time is between 100 ms and 3 sec (depending on overload or at short circuit). Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit. Maximum cable lenghts EPD24 reliably trips from 0 up to max. circuit resistance Rmax. Calculation of Rmax Selected rating IN (A) Operating voltage US (V DC) (= 80 % of 24 V) 2) Trip current Iab = 1.25 x IN (A) (EPD24 trips after 3 s) Rmax () = (UB/Iab) -0.050 3 19.2 3.75 5.07 2) Voltage drop of EPD24 and tolerance of trip point (typically 1.1 x IN = 1.05 ... 1.35 x IN) have been taken into account 6 19.2 7.50 2.51 Selection table for the incoming cable lengths with different cable cross-sections Cable cross section A (mm2) Cable length L (m) (= single length) 5 10 0.14 0.25 0.34 cable resistance () = (0 x 2 x L) / A 3) 1.27 0.71 0.52 2.54 1.42 1.05 0.5 0.36 0.71 15 3.81 2.14 1.57 1.07 20 5.09 2.85 2.09 1.42 25 6.36 3.56 2.62 1.78 30 7.63 4.27 3.14 2.14 35 8.90 4.98 3.66 2.49 40 10.17 5.70 4.19 2.85 45 11.44 6.41 4.71 3.20 50 12.71 7.12 5.24 3.56 75 19.07 10.68 7.85 5.34 100 25.34 14.24 10.47 7.12 125 31.79 17.80 13.09 8.90 150 38.14 21.36 15.71 10.68 175 44.50 24.92 18.32 12.46 200 50.86 28.48 20.94 14.24 225 57.21 32.04 23.56 16.02 250 63.57 35.60 26.18 17.80 0.75 0.24 0.47 0.71 0.95 1.19 1.42 1.66 1.90 2.14 2.37 3.56 4.75 5.93 7.12 8.31 9.49 10.68 11.87 3) Resistivity of copper 0 = 0.0178 ( x mm2)/m Example 1: max. length for 1.5 mm2 and 3 A: 214 m Example 2: max. length for 1.5 mm2 and 6 A: 106 m Example 3: mixed wiring: (Control cabinet --- sensor/actuator level) R1 = 40 m for 1.5 mm2 and R2 = 5 m for 0.25 mm2: R1 = 0.95 , R2 = 0.71 , total (R1 + R2) = 1.66 1.00 0.18 0.36 0.53 0.71 0.89 1.07 1.25 1.42 1.60 1.78 2.67 3.56 4.45 5.34 6.23 7.12 8.01 8.90 1.50 0.12 0.24 0.36 0.47 0.59 0.71 0.83 0.95 1.07 1.19 1.78 2.37 2.97 3.56 4.15 4.75 5.34 5.93 356 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Electronic protection devices EPD24 Technical diagrams El--Teimke/tCruorrennticshacrahcteerirsticScuircveherungsautomat ESX10-T Installations- und Sicherheitshinweise disconnection typically 1.1 x IN 1.8 x IN1) 10000 1000 ESX10-T Signaleingänge/-ausgänge (Anschlussdiagramme) trip time in seconds 100 current limitation 1) typically 1.8 x IN 10 5 1 X10-T Signaleingänge / -ausgänge (Anschlussdiagramme) e Signalkontakt0e.1 werden im Aus- oder Fehlerzustand gezeigt 0.01 0 1 X10-TA-100 ne Signaleingang/-Ausgang -- Wiring diagram 2 3 4 5 IK ...times rated current ESX10-TB-101 Ohne Signaleingang Mit Meldeausgang F (Einzelsignal, Schließer) 1) Current limitation typically 1.8 x IN at IN = 0.5 A...6 A Current limitation typically 1.5 x IN at IN = 8 A or 10 A Current limitation typically 1.3 x IN at IN = 12 A ESX10-TB-102 Ohne Signaleingang Mit Meldeausgang F (Einzelsignal, Öffner) LINEPED+24-TB1-101 without signal input with signal output F (Single signal, N/O) Operating condition: 13-14 closed Fault condition: 13-14 open LINE+ 1 14 LINE+ 1 12 13 11 2 LOAD+ 2 LOAD+ 2 LOAD+ 0V 3 0V 3 Normalzustand: 13-14 geschlossen Fehlerzustand: 13-14 geöffnet 0V 3 Normalzustand: 11-12 geöffnet Fehlerzustand: 11-12 geschlossen X10-TB-114 Steuereingang IN+ DC 24 V) Statusausgang SF 4 V = Lastausgang EIN) LINE+ 1 ESX10-TB-124 Mit Reseteingang RE (+DC 24 V ) Mit Statusausgang SF (+24 V = Lastausgang EIN) LINE+ 1 ESX10-TB-127 Mit Reseteingang RE (+DC 24 V ) Mit Statusausgang SF invertiert (0 V = Lastausgang EIN) LINE+ 1 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 357 -- Electronic protection devices EPD24 Approvals, Safety instructions Please note The user must ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the EPD24 used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 2006/42/EU and IEC/EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically by the EPD24. Information on UL approvals/CSA approvals UL1604 UL File # E 339238 CSA C22.2 No. 213 (Class I, Division 2) CSA File # 2305929 Operating Temperature Code T5 · This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only WARNING: · Exposure to some chemicals may degrade the sealing properties of materials used in the following device: relay Sealant Material: - Generic Name: Modified diglycidyl ether of bisphenol A - Supplier: Fine Polymers Corporation - Type: Epi Fine 4616L-160PK · Casing Material: - Generic Name: Liquid Crystal Polymer - Supplier: Sumitomo Chemical - Type: E4008, E4009, or E6008 RECOMMENDATION: · Periodically inspect the device named above for any degradation of properties and replace if degradation is found WARNING EXPLOSION HAZARD: · Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous · Substitution of any components may impair suitability for Class I, Division 2 UL2367 Non-hazardous use - UL File # E 339236 UL 508 Non-hazardous use - UL File # E 149922 CSA C22.2 No. 14 CSA C22.2 No. 142 - CSA File # E 2305929 Class 2 Meets requirement for Class 2 current limitation (EPD24 ... -0,5 A/1 A/2 A/3 A) 358 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES -- Electronic protection devices EPD24 Installation guidelines The EPD24 features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: · LINE+ (24 V DC) · 0V Caution: The electronic devices EPD24 require a 0 V connection · Auxiliary contacts LINE+ busbar 2CDE605100R0500 continuous busbar 500 mm length, cut (12.5 x n)-3 = length of busbars ± 0.5 e. g. (12.5 x 5)-3 = 59.5 ± 0.5 signal bar 2CDE605200R0021 remove protection against brush contact from bottom side 0 V busbar 2CDE605100R0500 insert busbars and protection slides to be flush with housing sides insert signal bars to be flush with housing and place them centrally over the contacts insert protection against brush contact 12.5 x n = width of protector block e. g. 12.5 x 5 = 62.5 Mounting procedure Before wiring insert busbars into protector block. A maximum of 10 connection cycles are permissible using connecting busbars. Recommendation After 10 units the busbars should be interrupted and receive a new entry live. Table of length for busbars (Order code 2CDE605100R0500) No. of units 2 Length of busbar (mm) ± 0.5 mm 22 3 4 34.5 47 5 6 59.5 72 7 8 84.5 97 9 10 109.5 122 ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES 359 360 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 361 -- Interface relays and optocouplers Table of contents 362 Offer overview 365 Applications 367 Pluggable interface relays and optocouplers 368 Selection tables 370 List of components 385 Benefits and advantages 386 Socket & terminal connection types 387 Relay components 389 Ordering details 410 Technical data 424 Technical diagrams 437 Boxed interface relays and optocouplers R600 range 438 Overview 440 Boxed interface relays R600 range 440 Selection table 442 Ordering details 444 Technical data 448 Technical diagrams 450 Boxed optocouplers R600 range 450 Selection table 451 Ordering details 453 Technical data 456 Technical diagrams 362 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Interface relays and optocouplers Offer overview Relays are universally applicable and are utilized in a diverse array of applications. They are a significant element in contemporary industrial processes and are used in applications where galvanic isolation, signal separation, voltage coupling and signal amplification are required. The ABB portfolio includes electromechanical relays and optocouplers. The electromechanical relays operate using an electromagnetic field whereas optocouplers use light. Optocouplers are predominantly used in applications where a high switching frequency is necessary. Furthermore, optocouplers do not contain any moving parts and are therefore bouncefree, immune to vibrations and possess a long electrical life. CR-S range The slim line of interface relays and optocouplers The pluggable interface relays and optocouplers of the CR-S range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-S range combines the flexibility of a modular system and the ability of switching high currents on a small footprint thus can be used in applications where space saving is essential. The CR-S range also includes complete versions consisting of a relay, socket and marker. CR-P range The pluggable pcb interface relays and optocouplers The pluggable interface relays of the CR-P range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-P range offers highest current switching in an IP67 rated relay housing. Furthermore, nine different coil voltages are available to suit world wide applications and even gold contact versions are available which is essential when it comes to switch sensitive signals. The CR-P range also includes complete versions consisting of a relay, socket, holder, marker and function module. ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 363 -- Interface relays and optocouplers Offer overview CR-M range The pluggable miniature interface relays The pluggable interface relays of the CR-M range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-M range offers up to 4 contacts in one relay and a built in test button which makes a circuit check fast and easy. 12 different coil voltages are available to suit world wide applications and even gold contact versions are available which is essential when it comes to switch sensitive signals. The CR-M range also includes complete versions consisting of a relay, socket, holder, marker and where applicable a function module. CR-U range The pluggable universal interface relays The pluggable interface relays of the CR-U range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-U range offers up to 3 contacts in one relay and a built in test button which makes a circuit check fast and easy. 12 different coil voltages are available to suit world wide applications. R600 range Boxed interface relays and optocouplers Boxed interface relays of the R600 range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The relay itself is built in thus the perfect solution because this design fulfills highest vibration requirements. The compact design and different connection terminal possibilities further optimize your panel installation. 364 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 365 -- Applications of interface relays A proven technology used worldwide Relays are universally applicable and are utilized in a diverse array of applications. They are a significant element in contemporary industrial processes and are used in applications where galvanic isolation, signal separation, voltage coupling and signal amplification are required. Circuit multiplication A single voltage signal may be used to simultaneously perform up to four different switching operations. Each output contact can be used to switch load circuits with different voltage and current levels. Galvanic isolation Interface relays are excellently suited to ensure safe galvanic isolation, i.e. separation between control circuit and load circuit. Voltage conversion Interface relays allow for small voltage signals to switch much larger loads. For example: a 24 V DC 10 mA signal can be used to switch a 230 V AC 16 A load. Billions of relays operate and interface between control circuits and electrical loads. Sensor 110 V AC 230 V AC Motor 380 V AC Interface relay Input 24 V DC Controller (PLC) Contactor 110 V AC 230 V AC 24 V DC Outout Interface relay 366 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 367 -- Pluggable interface relays and optocouplers Table of contents 368 Selection tables 370 List of components 385 Benefits and advantages 386 Socket & terminal connection types 387 Relay components 389 Ordering details 389 CR-S range 393 CR-P range 397 CR-M range 404 CR-P/M function modules 406 CR-U range 408 CR-U function modules 410 Technical data 410 CR-S interface relays 411 CR-S optocouplers 412 CR-S sockets 413 CR-S jumper bars 414 CR-P, CR-M, CR-U 418 CR-P optocouplers 419 CR-P and CR-M sockets 420 CR-P and CR-M jumper bars 421 CR-P and CR-M function modules 422 CR-U sockets 423 CR-U function modules 424 Technical diagrams 368 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays Selection table CR-S range How to use the selection table Choose the desired control supply voltage from the column "Control voltage", e.g. "5 V DC". Choose the desired kind of connection terminal from the column "Connection terminal", e.g. "spring". Choose the desired material of contact from the column "Contact Material" e.g. "gold plated". Control voltage 5 V DC 12 V AC Connection terminal screw spring screw spring Contact material standard gold plated standard gold plated standard gold plated standard gold plated Socket type CR-S006/024VDC1SS CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ Socket order code 1SVR405521R1100 1SVR405521R1100 1SVR405521R1200 1SVR405521R1200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 Relay type Relay order code CR-S005VDC1R CR-S005VDC1RG CR-S005VDC1R CR-S005VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG 1SVR405501R1010 1SVR405501R1020 1SVR405501R1010 1SVR405501R1020 1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 Example When you have chosen 5 V DC as control supply voltage, spring connection as connection terminal and gold plated as contact material the following order codes and type designators are valid: Socket: CR-S006/024VDC1SZ, 1SVR405521R1200 Relay: CR-S005VDC1RG, 1SVR405501R1020 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 369 -- CR-S range relay assemblies Control voltage 5 V DC Connection terminal screw spring 12 V DC screw spring 12 V AC 24 V DC screw spring screw spring 24 V AC screw spring 48 V AC/DC screw spring 60 V AC/DC screw spring 110-125 V AC/DC screw spring 220-240 V AC/DC screw spring Contact material standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated Socket type CR-S006/024VDC1SS CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S006/024VDC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S220/240VADC1SZ Socket order code 1SVR405521R1100 1SVR405521R1100 1SVR405521R1200 1SVR405521R1200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R6100 1SVR405521R6100 1SVR405521R6200 1SVR405521R6200 1SVR405521R7100 1SVR405521R7100 1SVR405521R7200 1SVR405521R7200 Relay type Relay order code CR-S005VDC1R CR-S005VDC1RG CR-S005VDC1R CR-S005VDC1RG CR-S012VDC1R 1SVR405501R1010 1SVR405501R1020 1SVR405501R1010 1SVR405501R1020 1SVR405501R2010 CR-S012VDC1RG 1SVR405501R2020 CR-S012VDC1R 1SVR405501R2010 CR-S012VDC1RG 1SVR405501R2020 CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S024VDC1R 1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 1SVR405501R3010 CR-S024VDC1RG 1SVR405501R3020 CR-S024VDC1R 1SVR405501R3010 CR-S024VDC1RG 1SVR405501R3020 CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG 1SVR405501R3010 1SVR405501R3020 1SVR405501R3010 1SVR405501R3020 1SVR405501R4010 1SVR405501R4020 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 -- CR-S optocoupler range relay assemblies Control voltage 24 V DC Connection terminal screw spring screw spring screw spring Output characteristics Transistor 100 mA - 48 V DC MOS-FET 2 A - 24 V DC Triac 2 A - 240 V AC Socket type CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ Socket order code 1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200 Opto type CR-S024VDC1TRA CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1MOS CR-S024VDC1TRI CR-S024VDC1TRI Opto order code 1SVR405510R3050 1SVR405510R3050 1SVR405510R3060 1SVR405510R3060 1SVR405510R3070 1SVR405510R3070 370 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- List of components Selection table CR-S range complete versions The complete versions of the CR-S range comprise of a pluggable interface relay, socket and marker. -- CR-S complete versions Relay Socket CR-S220/240VADC1SZ 1SVR405521R7200 CR-S220/240VADC1SS 1SVR405521R7100 CR-S110/125VADC1SZ 1SVR405521R6200 CR-S110/125VADC1SS 1SVR405521R6100 CR-S012/024VADC1SZ 1SVR405521R3200 CR-S012/024VADC1SS 1SVR405521R3100 1SVR405501R5020 1SVR405501R5010 1SVR405501R3020 Order code 1SVR405501R3010 CR-S060VDC1RG CR-S060VDC1R CR-S024VDC1RG Type CR-S024VDC1R Complete versions Order code 1SVR405541R3110 1SVR405541R3120 1SVR405541R3210 1SVR405541R3220 1SVR405541R6110 1SVR405541R6120 1SVR405541R6210 1SVR405541R6220 1SVR405541R7110 1SVR405541R7120 1SVR405541R7210 1SVR405541R7220 Type CR-S024VADC1CRS CR-S024VADC1CRGS CR-S024VADC1CRZ CR-S024VADC1CRGZ CR-S110VADC1CRS CR-S110VADC1CRGS CR-S110VADC1CRZ CR-S110VADC1CRGZ CR-S230VADC1CRS CR-S230VADC1CRGS CR-S230VADC1CRZ CR-S230VADC1CRGZ J J JJ J J J J J J J J J J J J J J J J J J J J 11111111122222222222222 JJJJ JJJJJJJJJ JJJJJJJJJJJJJJ J J J J J J J J Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 16 A 250 V 8 A Output contacts c/o Gold plated contacts J J J J J J J J J J J J J J J Type CR-P012DC1 CR-P024DC1 CR-P048DC1 CR-P110DC1 CR-P024AC1 CR-P048AC1 CR-P110AC1 CR-P120AC1 CR-P230AC1 CR-P012DC2 CR-P024DC2 CR-P048DC2 CR-P110DC2 CR-P012AC2 CR-P024AC2 CR-P048AC2 CR-P110AC2 CR-P120AC2 CR-P230AC2 CR-P024DC2G CR-P024AC2G CR-P110AC2G CR-P230AC2G Order code 1SVR405600R4000 1SVR405600R1000 1SVR405600R6000 1SVR405600R8000 1SVR405600R0000 1SVR405600R5000 1SVR405600R7000 1SVR405600R2000 1SVR405600R3000 1SVR405601R4000 1SVR405601R1000 1SVR405601R6000 1SVR405601R8000 1SVR405601R0200 1SVR405601R0000 1SVR405601R5000 1SVR405601R7000 1SVR405601R2000 1SVR405601R3000 1SVR405606R1000 1SVR405606R0000 1SVR405606R7000 1SVR405606R3000 -- CR-P pluggable relays -- Pluggable interface relays and optocouplers Selection table CR-P range 371 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS JJ JJJJJJ J JJJ J JJJJJJJJ JJJJJJJJJJJJJJJJJJ JJJJJ JJ JJJJJJ JJ JJJJ JJ JJJJ JJ JJJ JJJ 111111111122222222222222222 JJJJJJJJJJ JJJJJJJJJJJJJJJJJ Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 16 A 250 V 8 A Output contacts c/o Gold plated contacts Socket type Standard socket Logical socket Additional features LED Free-wheeling diode J JJJJJJ J JJJ J JJJJJJJ J J J JJJ J J Type CR-P012DC1SS42V CR-P024DC1SS42V CR-P024DC1LC42V CR-P024DC1LC62C CR-P110DC1SS42CV CR-P024AC1SS62CV CR-P120AC1SS92CV CR-P230AC1SS92CV CR-P230AC1LS CR-P230AC1LC92CV CR-P012DC2SS42V CR-P024DC2SS42V CR-P024DC2LS42 CR-P024DC2LS42V CR-P024DC2LC42 CR-P024DC2GLC42V CR-P024DC2GLC62C CR-P024DC2GLC62CV CR-P110DC2SS42CV CR-P024AC2SS62CV CR-P120AC2SS92CV CR-P230AC2SS92CV CR-P230AC2LS92CV CR-P230AC2LC92 CR-P230AC2GLC92 CR-P230AC2GLC92C CR-P230AC2GLC92CV Order code 1SVR405600R4010 1SVR405600R1010 1SVR405600R1011 1SVR405600R1013 1SVR405600R8010 1SVR405600R0010 1SVR405600R2010 1SVR405600R3110 1SVR405600R3011 1SVR405600R3010 1SVR405601R4010 1SVR405601R1010 1SVR405601R1013 1SVR405601R1011 1SVR405601R1012 1SVR405606R1010 1SVR405606R1013 1SVR405606R1011 1SVR405601R8010 1SVR405601R0010 1SVR405601R2010 1SVR405601R3110 1SVR405601R3011 1SVR405601R3012 1SVR405606R3013 1SVR405606R3012 1SVR405606R3010 -- CR-P range complete versions -- Pluggable interface relays and optocouplers Selection table CR-P range ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 372 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 373 -- List of components Selection table CR-P range complete versions The complete versions of the CR-P range comprise of a pluggable interface relay, socket, holder, marker and a function module. -- CR-P complete versions Relay Socket Function module Holder Order code 1SVR405601R4000 1SVR405601R1000 1SVR405606R1000 1SVR405601R8000 1SVR405601R0000 1SVR405601R2000 1SVR405601R3000 1SVR405606R3000 1SVR405650R1000 1SVR405650R0000 1SVR405650R0200 1SVR405652R0000 1SVR405652R1000 1SVR405652R9100 1SVR405655R0000 1SVR405655R1000 1SVR405654R0100 1SVR405655R0100 1SVR405655R1100 1SVR405659R0000 Type CR-P012DC2 CR-P024DC2 CR-P024DC2G CR-P110DC2 CR-P024AC2 CR-P120AC2 CR-P230AC2 CR-P230AC2G CR-PSS CR-PLS CR-PLC CR-P/M 42 CR-P/M 42V CR-P/M 42CV CR-P/M 62C CR-P/M 62CV CR-P/M 92 CR-P/M 92C CR-P/M 92CV CR-PH Complete versions Order code 1SVR405601R4010 1SVR405601R1010 1SVR405601R1013 1SVR405601R1011 1SVR405601R1012 1SVR405606R1010 1SVR405606R1013 1SVR405606R1011 1SVR405601R8010 1SVR405601R0010 1SVR405601R2010 1SVR405601R3110 1SVR405601R3011 1SVR405601R3012 1SVR405606R3013 1SVR405606R3012 1SVR405606R3010 Type CR-P012DC2SS42V CR-P024DC2SS42V CR-P024DC2LS42 CR-P024DC2LS42V CR-P024DC2LC42 CR-P024DC2GLC42V CR-P024DC2GLC62C CR-P024DC2GLC62CV CR-P110DC2SS42CV CR-P024AC2SS62CV CR-P120AC2SS92CV CR-P230AC2SS92CV CR-P230AC2LS92CV CR-P230AC2LC92 CR-P230AC2GLC92 CR-P230AC2GLC92C CR-P230AC2GLC92CV J J J J J J J J J JJ J J JJ J J JJ J J JJ J J J J J J J J J J J J J J J J J JJ JJ JJ JJ JJ JJ J J JJ J J JJ J J JJ J J JJ 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 333 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 JJJJJJJJJJJJ JJJJJJJJJJJJJ JJJJJJJJJJJJ J J J J J J J J J Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode J J J J J J J J J J J J J J J J J J J J J J J J J J J J Type CR-M012DC2 CR-M024DC2 CR-M048DC2 CR-M060DC2 CR-M110DC2 CR-M125DC2 CR-M220DC2 CR-M024AC2 CR-M048AC2 CR-M110AC2 CR-M120AC2 CR-M230AC2 CR-M012DC3 CR-M024DC3 CR-M048DC3 CR-M060DC3 CR-M110DC3 CR-M125DC3 CR-M220DC3 CR-M024AC3 CR-M048AC3 CR-M060AC3 CR-M110AC3 CR-M120AC3 CR-M230AC3 CR-M012DC4 CR-M024DC4 CR-M048DC4 CR-M060DC4 CR-M110DC4 CR-M125DC4 CR-M220DC4 CR-M024AC4 CR-M048AC4 CR-M110AC4 CR-M120AC4 CR-M230AC4 Order code 1SVR405611R4000 1SVR405611R1000 1SVR405611R6000 1SVR405611R4200 1SVR405611R8000 1SVR405611R8200 1SVR405611R9000 1SVR405611R0000 1SVR405611R5000 1SVR405611R7000 1SVR405611R2000 1SVR405611R3000 1SVR405612R4000 1SVR405612R1000 1SVR405612R6000 1SVR405612R4200 1SVR405612R8000 1SVR405612R8200 1SVR405612R9000 1SVR405612R0000 1SVR405612R5000 1SVR405612R5200 1SVR405612R7000 1SVR405612R2000 1SVR405612R3000 1SVR405613R4000 1SVR405613R1000 1SVR405613R6000 1SVR405613R4200 1SVR405613R8000 1SVR405613R8200 1SVR405613R9000 1SVR405613R0000 1SVR405613R5000 1SVR405613R7000 1SVR405613R2000 1SVR405613R3000 -- CR-M pluggable relays without LED -- Pluggable interface relays and optocouplers Selection table CR-M range ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 374 JJJ JJJ JJJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJ 2222222222222222222 JJ JJ JJ J JJ JJ JJ J J J J J J Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode Type CR-M012DC2L CR-M012DC2LD CR-M024DC2L CR-M024DC2LD CR-M048DC2L CR-M048DC2LD CR-M060DC2L CR-M110DC2L CR-M110DC2LD CR-M125DC2L CR-M125DC2LD CR-M220DC2L CR-M220DC2LD CR-M012AC2L CR-M024AC2L CR-M048AC2L CR-M110AC2L CR-M120AC2L CR-M230AC2L Order code 1SVR405611R4100 1SVR405611R4400 1SVR405611R1100 1SVR405611R1400 1SVR405611R6100 1SVR405611R6400 1SVR405611R4300 1SVR405611R8100 1SVR405611R8400 1SVR405611R8300 1SVR405611R8500 1SVR405611R9100 1SVR405611R9400 1SVR405611R0300 1SVR405611R0300 1SVR405611R5100 1SVR405611R7100 1SVR405611R2100 1SVR405611R3100 -- CR-M pluggable relays with LED -- Pluggable interface relays and optocouplers Selection table CR-M range 375 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS JJJ JJJ JJJJJJJJJJJJJJJJJJJ 3333333333333333333 JJJJJJJJJJJJJJJJJJJ JJ JJ JJ J JJ JJ JJ J J J J J J Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode Type CR-M012DC3L CR-M012DC3LD CR-M024DC3L CR-M024DC3LD CR-M048DC3L CR-M048DC3LD CR-M060DC3L CR-M110DC3L CR-M110DC3LD CR-M125DC3L CR-M125DC3LD CR-M220DC3L CR-M220DC3LD CR-M012AC3L CR-M024AC3L CR-M048AC3L CR-M110AC3L CR-M120AC3L CR-M230AC3L Order code 1SVR405612R4100 1SVR405612R4400 1SVR405612R1100 1SVR405612R1400 1SVR405612R6100 1SVR405612R6400 1SVR405612R4300 1SVR405612R8100 1SVR405612R8400 1SVR405612R8300 1SVR405612R8500 1SVR405612R9100 1SVR405612R9400 1SVR405612R0300 1SVR405612R0100 1SVR405612R5100 1SVR405612R7100 1SVR405612R2100 1SVR405612R3100 -- CR-M pluggable relays with LED -- Pluggable interface relays and optocouplers Selection table CR-M range ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 376 JJJ JJJ JJJJJJJJJJJJJJJJJJJ 4444444444444444444 JJ JJ JJ J JJ JJ JJ J J J J J J JJJJJJJJJJJJJJJJJJJ Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode Type CR-M012DC4L CR-M012DC4LD CR-M024DC4L CR-M024DC4LD CR-M048DC4L CR-M048DC4LD CR-M060DC4L CR-M110DC4L CR-M110DC4LD CR-M125DC4L CR-M125DC4LD CR-M220DC4L CR-M220DC4LD CR-M012AC4L CR-M024AC4L CR-M048AC4L CR-M110AC4L CR-M120AC4L CR-M230AC4L Order code 1SVR405613R4100 1SVR405613R4400 1SVR405613R1100 1SVR405614R1100 1SVR405613R6100 1SVR405613R6400 1SVR405613R4300 1SVR405613R8100 1SVR405613R8400 1SVR405613R8300 1SVR405613R8500 1SVR405613R9100 1SVR405613R9400 1SVR405613R0300 1SVR405613R0100 1SVR405613R5100 1SVR405613R7100 1SVR405613R2100 1SVR405613R3100 -- CR-M pluggable relays with LED -- Pluggable interface relays and optocouplers Selection table CR-M range 377 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 4444444444444444444 JJJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJ JJ JJJJJJJJJJJJJJJJJJJ J J J J JJ Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode J J J J J J J J J J J J J Type CR-M024DC4G CR-M024AC4G CR-M110AC4G CR-M230AC4G CR-M230AC4G CR-M012DC4LG CR-M024DC4LG CR-M048DC4LG CR-M060DC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG CR-M024AC4LG CR-M048AC4LG CR-M110AC4LG CR-M120AC4LG CR-M230AC4LG CR-M012DC4LDG CR-M024DC4LDG Order code 1SVR405618R1000 1SVR405618R0000 1SVR405618R7000 1SVR405618R3000 1SVR405618R3000 1SVR405618R4100 1SVR405618R1100 1SVR405618R6100 1SVR405618R4300 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 1SVR405618R0100 1SVR405618R5100 1SVR405618R7100 1SVR405618R2100 1SVR405618R3100 1SVR405618R4400 1SVR405618R1400 -- CR-M pluggable relays with Gold Plated Contacts -- Pluggable interface relays and optocouplers Selection table CR-M range ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 378 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 379 -- Pluggable interface relays and optocouplers Selection table CR-M range complete versions -- CR-M range complete versions 1SVR405618R3111 1SVR405618R3110 CR-M230AC4GSS92CV 1SVR405618R3112 1SVR405613R3012 CR-M230AC4LS92CV 1SVR405613R3011 CR-M230AC4SS92CV 1SVR405613R3110 CR-M024AC4LS62CV 1SVR405613R0010 CR-M024DC4LDGSS 1SVR405618R1410 CR-M024DC4LGLC22 1SVR405618R1110 CR-M024DC4GLC62CV 1SVR405618R1010 CR-M024DC4GSS42V 1SVR405618R1011 1SVR405613R1012 CR-M024DC4LS42V 1SVR405613R1011 CR-M024DC4SS42V 1SVR405613R1010 CR-M012DC4LDGSS 1SVR405618R4410 Order code CR-M230AC4LGSS CR-M230AC4LGLC CR-M230AC4LC92 CR-M024DC4LC42 Type Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Socket type Standard socket Logical socket Additional features LED Free-wheeling diode J JJJJJJJ J JJJJJJ JJJJJJJJJJJJJJJ 444444444444444 J JJJJ JJJ JJ J J J J J JJ JJ J JJ J JJJJJJJJJJJJJJJ JJJJJ JJ JJ 380 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- List of components Selection table CR-M range complete versions The complete versions of the CR-M range comprise of a pluggable interface relay, socket, holder, marker and where applicable a function module. -- CR-M complete versions Relay Socket Function module Holder Order code 1SVR405618R4400 1SVR405613R1000 1SVR405618R1000 1SVR405618R1100 1SVR405618R1400 1SVR405613R0000 1SVR405613R3000 1SVR405618R3000 1SVR405618R3100 1SVR405651R3000 1SVR405651R3100 1SVR405651R3200 1SVR405651R0000 1SVR405652R0000 1SVR405652R1000 1SVR405652R9100 1SVR405655R1000 1SVR405654R0100 1SVR405655R1100 1SVR405659R1000 Type CR-M012DC4LDG CR-M024DC4 CR-M024DC4G CR-M024DC4LG CR-M024DC4LDG CR-M024AC4 CR-M230AC4 CR-M230AC4G CR-M230AC4LG CR-M4SS CR-M4LS CR-M4LC CR-P/M 22 CR-P/M 42 CR-P/M 42V CR-P/M 42CV CR-P/M 62CV CR-P/M 92 CR-P/M 92CV CR-MH Complete versions Order code 1SVR405618R4410 1SVR405613R1010 1SVR405613R1011 1SVR405613R1012 1SVR405618R1011 1SVR405618R1010 1SVR405618R1110 1SVR405618R1410 1SVR405613R0010 1SVR405613R3110 1SVR405613R3011 1SVR405613R3012 1SVR405618R3112 1SVR405618R3110 1SVR405618R3111 Type CR-M012DC4LDGSS CR-M024DC4SS42V CR-M024DC4LS42V CR-M024DC4LC42 CR-M024DC4GSS42V CR-M024DC4GLC62CV CR-M024DC4LGLC22 CR-M024DC4LDGSS CR-M024AC4LS62CV CR-M230AC4SS92CV CR-M230AC4LS92CV CR-M230AC4LC92 CR-M230AC4GSS92CV CR-M230AC4LGLC CR-M230AC4LGSS J J J J J J J J J JJ J J J J J J JJ J J J J J J J J J J JJ J J JJ J J J J J J J J J J J JJ JJ JJ JJ J J JJJJJJ JJJ JJJJJJ JJJ JJJ JJJJJJ JJJJJJ JJJ J JJJJJJ J Related control supply voltage 6-220 V DC 6-24 V DC 24-60 V DC 110 V DC 110-230 V DC 6-24 V AC 24-60 V AC 110-230 V AC 24 V AC 115 V AC 230 V AC 24-240 V AC/DC Function Diode - reverse polarity protection / free-wheeling diode Diode and LED - reverse polarity protection / free-wheeling diode RC element - spark quenching Diode and LED Varistor and LED - overvoltage protection Varistor - overvoltage protection LED red LED green J J JJ JJ J JJ JJ J JJ J JJ JJ JJ J JJ JJ JJ JJJ JJ JJ JJ J Type CR-P/M 22 CR-P/M 42 CR-P/M 42V CR-P/M 42B CR-P/M 42BV CR-P/M 42C CR-P/M 42CV CR-P/M 52B CR-P/M 52D CR-P/M 52C CR-P/M 62 CR-P/M 62V CR-P/M 62E CR-P/M 62EV CR-P/M 92 CR-P/M 92V CR-P/M 62C CR-P/M 62CV CR-P/M 62D CR-P/M 62DV CR-P/M 92C CR-P/M 92CV CR-P/M 72 CR-P/M 72A CR-P/M 82 Order code 1SVR405651R0000 1SVR405652R0000 1SVR405652R1000 1SVR405652R4000 1SVR405652R4100 1SVR405652R9000 1SVR405652R9100 1SVR405653R0000 1SVR405653R4000 1SVR405653R1000 1SVR405654R0000 1SVR405654R1000 1SVR405654R4000 1SVR405654R4100 1SVR405654R0100 1SVR405654R1100 1SVR405655R0000 1SVR405655R1000 1SVR405655R4000 1SVR405655R4100 1SVR405655R0100 1SVR405655R1100 1SVR405656R0000 1SVR405656R1000 1SVR405656R2000 -- CR-P/M function modules -- Pluggable interface relays and optocouplers Selection table CR-P/M function modules 381 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 2222222222333333333333 JJJJJJJJJJJJJJJJJJJJJJ J J J J J J J J J J J Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 10 A Output contacts c/o Gold plated contacts J J J J J J J J J J J Type CR-U012DC2 CR-U024DC2 CR-U048DC2 CR-U110DC2 CR-U220DC2 CR-U024AC2 CR-U048AC2 CR-U110AC2 CR-U120AC2 CR-U230AC2 CR-U012DC3 CR-U024DC3 CR-U048DC3 CR-U110DC3 CR-U125DC3 CR-U220DC3 CR-U024AC3 CR-U048AC3 CR-U060AC3 CR-U110AC3 CR-U120AC3 CR-U230AC3 Order code 1SVR405621R4000 1SVR405621R1000 1SVR405621R6000 1SVR405621R8000 1SVR405621R9000 1SVR405621R0000 1SVR405621R5000 1SVR405621R7000 1SVR405621R2000 1SVR405621R3000 1SVR405622R4000 1SVR405622R1000 1SVR405622R6000 1SVR405622R8000 1SVR405622R8200 1SVR405622R9000 1SVR405622R0000 1SVR405622R5000 1SVR405622R5200 1SVR405622R7000 1SVR405622R2000 1SVR405622R3000 -- CR-U pluggable relays without LED -- Pluggable interface relays and optocouplers Selection table CR-U range ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 382 JJJJ JJJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ 2222222222 2 2222333333333333333 JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ J J J J J J Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 10 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode JJ JJ JJ J J J J J J JJ JJ JJ JJ J J J J Type CR-U012DC2L CR-U012DC2LD CR-U024DC2L CR-U024DC2LD CR-U048DC2L CR-U048DC2LD CR-U110DC2L CR-U110DC2LD CR-U220DC2L CR-U012AC2L CR-U024AC2L CR-U048AC2L CR-U110AC2L CR-U120AC2L CR-U230AC2L CR-U012DC3L CR-U012DC3LD CR-U024DC3L CR-U024DC3LD CR-U048DC3L CR-U048DC3LD CR-U110DC3L CR-U110DC3LD CR-U220DC3L CR-U012AC3L CR-U024AC3L CR-U048AC3L CR-U110AC3L CR-U120AC3L CR-U230AC3L Order code 1SVR405621R4100 1SVR405621R4400 1SVR405621R1100 1SVR405621R1400 1SVR405621R6100 1SVR405621R6400 1SVR405621R8100 1SVR405621R8400 1SVR405621R9100 1SVR405621R0300 1SVR405621R0100 1SVR405621R5100 1SVR405621R7100 1SVR405621R2100 1SVR405621R3100 1SVR405622R4100 1SVR405622R4400 1SVR405622R1100 1SVR405623R1100 1SVR405622R6100 1SVR405622R6400 1SVR405622R8100 1SVR405622R8400 1SVR405622R9100 1SVR405622R0300 1SVR405622R0100 1SVR405622R5100 1SVR405622R7100 1SVR405622R2100 1SVR405622R3100 -- CR-U pluggable relays with LED -- Pluggable interface relays and optocouplers Selection table CR-U range 383 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 384 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Selection table CR-U function modules -- CR-U function modules Order code 1SVR405661R0000 1SVR405662R0000 1SVR405662R1000 1SVR405662R4000 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405663R0000 1SVR405663R4000 1SVR405663R1000 1SVR405664R0000 1SVR405664R1000 1SVR405664R4000 1SVR405664R4100 1SVR405664R0100 1SVR405664R1100 1SVR405665R0000 1SVR405665R1000 1SVR405665R4000 1SVR405665R4100 1SVR405665R0100 1SVR405665R1100 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 1SVR405677R0000 Type CR-U 21 CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV CR-U 51B CR-U 51D CR-U 51C CR-U 61 CR-U 61V CR-U 61E CR-U 61EV CR-U 91 CR-U 91V CR-U 61C CR-U 61CV CR-U 61D CR-U 61DV CR-U 91C CR-U 91CV CR-U 71 CR-U 71A CR-U 81 CR-U T Related control supply voltage 6-220 V DC 6-24 V DC 24-60 V DC 110 V DC 110-230 V DC 6-24 V AC 24-60 V AC 110-230 V AC 24 V AC 115 V AC 230 V AC 24-240 V AC/DC Function Diode - reverse polarity protection / free wheeling diode Diode and LED - Reverse polarity protection / free-wheeling diode and LED to indicate energized coil RC element - Spark quenching Diode and LED - LED to indicate energized coil Varistor and LED - Overvoltage protection and LED to indicate energized coil Varistor - Overvoltage protection Multi-function time module LED red LED green J JJ J JJ JJ JJ J JJ JJ JJ J JJ JJ J JJ JJ J JJ JJ J JJ JJ J J J J J JJJJJJ JJJ JJJJJJ JJJJJJ JJJ JJJ JJJ J JJJJJJ JJJJJJ J ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 385 -- Pluggable interface relays and optocouplers Benefits and advantages ABB's interface relays and optocouplers ensure a reliable voltage conversion between process peripherals and higher level control systems. These relays ensure reliable signal switching and provide electrical isolation for sensitive electronics such as PLCs. The wide variety of pluggable interface relays with accompanied by standard or logic sockets may be used for switching AC or DC loads. Suitable for extreme environments, ABB's interface relays are offered across a wide spectrum of coil voltages, with a variety of optional function modules. Continuous operation The interface relay portfolio incorporates a large assortment of relays. It includes both electromechanical relays and optocouplers. Optocouplers allow for continuous operation without any mechanical wear-and -tear. Easy to install The interface relay includes both pluggable and non-pluggable relays. The plugggable relays allow for the easy and seamless exchange of relay modules. The ABB interface relays and optocouplers are approved for a large variety of applications, comply to Global availability the highest global approvals and are available world-wide. 386 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Socket and terminal connection types Standard sockets -- 01 Standard socket CR-P Logical sockets 2CDC291040F0004 2CDC291009S0011 -- 02 Standard socket CR-M Position of connection terminals: Coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket. Position of connection terminals: Coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on the upper side of the socket. 2CDC291006S0011 2CDC291042F0004 -- 03 Logical socket CR-P -- 04 Logical socket CR-M Terminal connection types -- 05 Screw type -- 06 Spring type -- 07 Fork type A variety of sockets are available for interface relays and optocouplers to meet the needs of different applications such as vibration- intensive environments. ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 387 -- Pluggable interface relays and optocouplers Relay components -- CR-S range Socket Marker Pluggable interface relay LED -- CR-P range Socket Pluggable function module Pluggable interface relay Plastic holder Marker 388 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Relay components -- CR-M range Socket -- CR-U range Pluggable function module Test button Pluggable interface relay Holder Marker Socket Pluggable function module Test button Pluggable interface relay Holder ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 389 -- Pluggable interface relays and optocouplers Ordering details CR-S range CR-S relay CR-S optocoupler CR-S complete interface relay 2CDC 291 003 S0016 2CDC292008F0016 2CDC 291 005 S0014 The slim pluggable interface relays and optocouplers of the CR-S range may be used for electrical isolation, amplification and signal matching. The CR-S relays are 6.2 mm wide and therefore allow for the switching high currents on a small footprint. -- Ordering details - CR-S range pluggable interface relays Rated control Outputs supply voltage Contact ratings Type Order code 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC 1 c/o (SPDT) standard contacts 250 V, 6 A 1 c/o (SPDT) gold plated contacts 12 V, 250 mA (3W)1) CR-S005VDC1R CR-S012VDC1R CR-S024VDC1R CR-S048VDC1R CR-S060VDC1R CR-S005VDC1RG CR-S012VDC1RG CR-S024VDC1RG CR-S048VDC1RG CR-S060VDC1RG 1SVR405501R1010 1SVR405501R2010 1SVR405501R3010 1SVR405501R4010 1SVR405501R5010 1SVR405501R1020 1SVR405501R2020 1SVR405501R3020 1SVR405501R4020 1SVR405501R5020 Pkg Weight (1 pc.) qty kg (lb) 10 0.005 (0.011) 10 0.005 (0.011) -- Ordering details - CR-S range pluggable optocouplers Rated control Outputs supply voltage Type 24 V DC Transistor, 100 mA - 48 V DC MOS-FET, 2 A - 24 V DC Triac, 2 A - 240 V AC CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1TRI Order code 1SVR405510R3050 1SVR405510R3060 1SVR405510R3070 Pkg Weight (1 pc.) qty kg (lb) 10 0.004 (0.009) -- Ordering details - CR-S range complete interface relays (relay + socket) Rated control Outputs Contact ratings Type supply voltage Order code 24 V AC/DC 110 V AC/DC 230 V AC/DC 24 V AC/DC 110 V AC/DC 230 V AC/DC 1 c/o (SPDT) standard contacts 250 V, 6 A 1 c/o (SPDT) gold plated contacts 12 V, 250 mA (3W)1) CR-S024VADC1CRS CR-S024VADC1CRZ CR-S110VADC1CRS CR-S110VADC1CRZ CR-S230VADC1CRS CR-S230VADC1CRZ CR-S024VADC1CRGS CR-S024VADC1CRGZ CR-S110VADC1CRGS CR-S110VADC1CRGZ CR-S230VADC1CRGS CR-S230VADC1CRGZ 1SVR405541R3110 1SVR405541R3210 1SVR405541R6110 1SVR405541R6210 1SVR405541R7110 1SVR405541R7210 1SVR405541R3120 1SVR405541R3220 1SVR405541R6120 1SVR405541R6220 1SVR405541R7120 1SVR405541R7220 Pkg Weight (1 pc.) qty kg (lb) 10 0.03 (0.066) 10 0.03 (0.066) 1) If specified maximum values exceeded, the gold plating is destroyed. The maximum values of the standard contacts are then valid. 390 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-S range CR-S socket 2CDC292008F0016 -- Ordering details - CR-S range sockets Rated control Connection type supply voltage Type 6-24 V DC 12-24 V AC/DC 48-60 V AC/DC 110-125 V AC/DC 220-240 V AC/DC screw spring screw spring screw spring screw spring screw spring CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SZ -- Ordering details - CR-S range accessories Version Type Order code 1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405521R5100 1SVR405521R5200 1SVR405521R6100 1SVR405521R6200 1SVR405521R7100 1SVR405521R7200 Order code Jumper bar 20 pole, blue color Jumper bar 20 pole, red color Jumper bar 20 pole, black color Separator CR-SJB20-BLUE CR-SJB20-RED CR-SJB20-BLACK CR-SSEP 1SVR405598R0700 1SVR405598R0800 1SVR405598R0900 1SVR405599R0000 Pkg Weight (1 pc.) qty kg (lb) 10 0.025 (0.055) Pkg Weight (1 pc.) qty kg (lb) 10 0.008 (0.018) 10 0.012 (0.026) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 391 -- Pluggable interface relays and optocouplers Ordering details CR-S range -- Relay assemblies Control voltage 5 V DC 12 V DC Connection terminal screw spring screw Contact material standard gold plated standard gold plated standard gold plated spring standard gold plated 12 V AC 24 V DC screw spring screw standard gold plated standard gold plated standard gold plated spring standard gold plated 24 V AC screw spring 48 V AC/DC screw spring 60 V AC/DC screw spring 110-125 V AC/DC screw spring 220-240 V AC/DC screw spring standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated Socket type Socket order code Relay type Relay order code CR-S006/024VDC1SS CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S006/024VDC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S220/240VADC1SZ 1SVR405521R1100 1SVR405521R1100 1SVR405521R1200 1SVR405521R1200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R6100 1SVR405521R6100 1SVR405521R6200 1SVR405521R6200 1SVR405521R7100 1SVR405521R7100 1SVR405521R7200 1SVR405521R7200 CR-S005VDC1R CR-S005VDC1RG CR-S005VDC1R CR-S005VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG 1SVR405501R1010 1SVR405501R1020 1SVR405501R1010 1SVR405501R1020 1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 1SVR405501R3010 1SVR405501R3020 1SVR405501R3010 1SVR405501R3020 1SVR405501R3010 1SVR405501R3020 1SVR405501R3010 1SVR405501R3020 1SVR405501R4010 1SVR405501R4020 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 392 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-S range -- Optocoupler assemblies Control voltage 24 V DC Connection terminal screw spring screw spring screw spring Output characteristics Transistor 100 mA - 48 V DC MOS-FET 2 A - 24 V DC Triac 2 A - 240 V AC Socket type Socket order code CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ 1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200 Opto type CR-S024VDC1TRA CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1MOS CR-S024VDC1TRI CR-S024VDC1TRI Opto order code 1SVR405510R3050 1SVR405510R3050 1SVR405510R3060 1SVR405510R3060 1SVR405510R3070 1SVR405510R3070 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 393 -- Pluggable interface relays and optocouplers Ordering details CR-P range CR-P relay CR-P optocoupler 2CDC 291 006 S0016 2CDC 291 045 F0004 The CR-P range offers the highest current switching in an IP67 rated relay housing. This range comprises of pluggable interface relays and optocouplers offered in 10 different control supply voltages. Additionally, gold plated contacts are available for applications where sensitive signals are to be switched. The CR-P range also includes complete versions consisting of a relay, socket, holder, marker and function module. -- Ordering details - CR-P range relays Rated control Outputs Contact ratings supply voltage Type 12 V DC 24 V DC 48 V DC 110 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 1 c/o (SPDT) 250 V, 16 A 2 c/o (SPDT) 250 V, 8 A CR-P012DC1 CR-P024DC1 CR-P048DC1 CR-P110DC1 CR-P024AC1 CR-P048AC1 CR-P110AC1 CR-P120AC1 CR-P230AC1 CR-P012DC2 CR-P024DC2 CR-P048DC2 CR-P110DC2 CR-P012AC2 CR-P024AC2 CR-P048AC2 CR-P110AC2 CR-P120AC2 CR-P230AC2 Order code 1SVR405600R4000 1SVR405600R1000 1SVR405600R6000 1SVR405600R8000 1SVR405600R0000 1SVR405600R5000 1SVR405600R7000 1SVR405600R2000 1SVR405600R3000 1SVR405601R4000 1SVR405601R1000 1SVR405601R6000 1SVR405601R8000 1SVR405601R0200 1SVR405601R0000 1SVR405601R5000 1SVR405601R7000 1SVR405601R2000 1SVR405601R3000 Pkg Weight (1 pc.) qty kg (lb) 10 0.014 (0.031) 10 0.014 (0.031) -- Ordering details - CR-P range relays with gold contacts Rated control Outputs Contact ratings Type supply voltage Order code 24 V DC 24 V AC 110 V AC 230 V AC 2 c/o (SPDT) gold contact 250 V, 8 A CR-P024DC2G CR-P024AC2G CR-P110AC2G CR-P230AC2G 1SVR405606R1000 1SVR405606R0000 1SVR405606R7000 1SVR405606R3000 Pkg Weight (1 pc.) qty kg (lb) 10 0.014 (0.031) -- Ordering details - CR-P range pluggable optocouplers Rated control supply voltage (Us) 10-32 V DC Outputs MOS-FET, 5 A - 35 V DC Triac, 3 A - 275 V AC Type Order code CR-P024MOS1 CR-P024TRI1 1SVR405610R4060 1SVR405610R4070 Pkg Weight (1 pc.) qty kg (lb) 10 0.011 (0.618) 394 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-P range CR-PLSX CR-PSS CR-PJ 2CDC291040F0004 2CDC 291 004 F0007 2CDC291088F0004 Standard and logical sockets for CR-P interface relays are suitable for snap-on mounting onto a DIN rail. Optional function modules for the CR-P range are plugged into both standard and logical sockets. -- Ordering details - Sockets* Version Connection terminal Type Order code Logical socket with protective separation Logical socket Standard socket screw screw spring screw *All CR-P socket packages include a set of markers. CR-PLS CR-PLSX CR-PLC CR-PSS 1SVR405650R0000 1SVR405650R0100 1SVR405650R0200 1SVR405650R1000 Pkg Weight (1 pc.) qty kg (lb) 10 0.045 (0.099) 0.043 (0.095) 0.042 (0.093) 0.038 (0.084) Standard sockets Position of connection terminals: coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket. Logical sockets Position of connection terminals: coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on the upper side of the socket. -- Ordering details - Accessories Version Plastic holder for socket Metal holder for socket Jumper bar for sockets with screw connection Marker Type CR-PH CR-PH1 CR-PJ CR-PM Order code 1SVR405659R0000 1SVR405659R0100 1SVR405658R5000 1SVR405658R0000 Pkg Weight (1 pc.) qty kg (lb) 10 0.002 (0.004) 0.4g 0.018 (0.040) 10 0.0002 (0.0004) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 395 -- Pluggable interface relays and optocouplers Ordering details CR-P range CR-P complete version 2CDC291001F0019 -- Ordering details - CR-P range complete versions Rated control supply voltage 12 V DC 24 V DC 110 V DC 24 V AC 120 V AC 230 V AC Out- Description puts Socket Connection Type type terminal Order code Pkg Weight (1 pc.) qty kg (lb) 1 c/o Reverse polarity protection and freewheeling diode, LED green, holder standard screw 1 c/o Reverse polarity protection and freewheeling diode, LED green, holder standard screw Reverse polarity protection and freewheeling diode, LED green, holder logical spring Varistor and LED red, holder logical spring 1 c/o Reverse polarity protection and freewheeling diode, LED green, holder standard screw 1 c/o Varistor and standard screw LED green, holder 1 c/o Varistor and standard screw LED green, holder 1 c/o Reverse polarity protection and freewheeling diode, LED green, holder standard screw Holder logical screw Varistor and logical spring LED green, holder CR-P012DC1SS42V 1SVR405600R4010 10 0.057 (0.126) CR-P024DC1SS42V 1SVR405600R1010 10 0.057 (0.126) CR-P024DC1LC42V 1SVR405600R1011 10 0.057 (0.126) CR-P024DC1LC62C 1SVR405600R1013 10 CR-P110DC1SS42CV 1SVR405600R8010 10 0.057 (0.126) 0.057 (0.126) CR-P024AC1SS62CV 1SVR405600R0010 10 CR-P120AC1SS92CV 1SVR405600R2010 10 CR-P230AC1SS92CV 1SVR405600R3110 10 0.057 (0.126) 0.057 (0.126) 0.057 (0.126) CR-P230AC1LS 1SVR405600R3011 10 CR-P230AC1LC92CV 1SVR405600R3010 10 0.057 (0.126) 0.057 (0.126) 396 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-P range CR-P complete version 2CDC291001F0019 -- Ordering details - CR-P range complete versions Rated control supply voltage 12 V DC 24 V DC 24 V DC 110 V DC 24 V AC 120 V AC 230 V AC 230 V AC Outputs 2 c/o 2 c/o 2 c/o gold plated 2 c/o 2 c/o 2 c/o 2 c/o 2 c/o gold plated Description Socket type Connection terminal Reverse polarity protection and freewheeling diode, LED green, holder standard screw Reverse polarity protection and freewheeling diode, LED green, holder standard screw Reverse polarity protection and freewheeling diode, LED red, holder logical screw Reverse polarity protection and freewheeling diode, LED green, holder logical screw Reverse polarity protection and freewheeling diode, LED red, holder logical spring Reverse polarity protection and freewheeling diode, LED green, holder logical spring Varistor and LED logical spring red, holder Varistor and LED logical spring green, holder Reverse polarity protection and freewheeling diode, LED green, holder standard screw Varistor and standard screw LED green, holder Varistor and standard screw LED green, holder Reverse polarity standard screw protection and freewheeling diode, LED green, holder Varistor and logical screw LED green, holder Diode and LED red, holder logical spring Diode and LED red, holder logical spring Varistor and LED red, holder logical spring Varistor and logical spring LED green, holder Type Order code Pkg Weight (1 pc.) qty kg (lb) CR-P012DC2SS42V 1SVR405601R4010 10 0.057 (0.126) CR-P024DC2SS42V 1SVR405601R1010 10 0.057 (0.126) CR-P024DC2LS42 1SVR405601R1013 10 0.057 (0.126) CR-P024DC2LS42V 1SVR405601R1011 10 0.057 (0.126) CR-P024DC2LC42 1SVR405601R1012 10 0.057 (0.126) CR-P024DC2GLC42V 1SVR405606R1010 10 0.057 (0.126) CR-P024DC2GLC62C 1SVR405606R1013 10 CR-P024DC2GLC62CV 1SVR405606R1011 10 CR-P110DC2SS42CV 1SVR405601R8010 10 0.057 (0.126) 0.057 (0.126) 0.057 (0.126) CR-P024AC2SS62CV 1SVR405601R0010 10 CR-P120AC2SS92CV 1SVR405601R2010 10 CR-P230AC2SS92CV 1SVR405601R3110 10 0.057 (0.126) 0.057 (0.126) 0.057 (0.126) CR-P230AC2LS92CV 1SVR405601R3011 10 CR-P230AC2LC92 1SVR405601R3012 10 CR-P230AC2GLC92 1SVR405606R3013 10 CR-P230AC2GLC92C 1SVR405606R3012 10 CR-P230AC2GLC92CV 1SVR405606R3010 10 0.057 (0.126) 0.057 (0.126) 0.057 (0.126) 0.057 (0.126) 0.057 (0.126) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 397 -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M 2CDC 291 002 F0015 The CR-M range offers the possibility of switching up to 4 different circuits with a single relay. The integrated LED and test button* allow for easy testing and commissioning. This range of relays are available at a wide range of different coil voltages and are accompanied by a wide variety of function modules. The CR-M range also includes complete versions consisting of a relay, socket, holder, marker and where applicable, function module. -- Ordering details - CR-M range without LED Rated control Outputs Contact supply voltage ratings Type 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 2 c/o (SPDT) 250 V, 12 A 3 c/o (SPDT) 250 V, 10 A 4 c/o (SPDT) 250 V, 6 A CR-M012DC2 CR-M024DC2 CR-M048DC2 CR-M060DC2 CR-M110DC2 CR-M125DC2 CR-M220DC2 CR-M024AC2 CR-M048AC2 CR-M110AC2 CR-M120AC2 CR-M230AC2 CR-M012DC3 CR-M024DC3 CR-M048DC3 CR-M060DC3 CR-M110DC3 CR-M125DC3 CR-M220DC3 CR-M024AC3 CR-M048AC3 CR-M060AC3 CR-M110AC3 CR-M120AC3 CR-M230AC3 CR-M012DC4 CR-M024DC4 CR-M048DC4 CR-M060DC4 CR-M110DC4 CR-M125DC4 CR-M220DC4 CR-M024AC4 CR-M048AC4 CR-M110AC4 CR-M120AC4 CR-M230AC4 Order code 1SVR405611R4000 1SVR405611R1000 1SVR405611R6000 1SVR405611R4200 1SVR405611R8000 1SVR405611R8200 1SVR405611R9000 1SVR405611R0000 1SVR405611R5000 1SVR405611R7000 1SVR405611R2000 1SVR405611R3000 1SVR405612R4000 1SVR405612R1000 1SVR405612R6000 1SVR405612R4200 1SVR405612R8000 1SVR405612R8200 1SVR405612R9000 1SVR405612R0000 1SVR405612R5000 1SVR405612R5200 1SVR405612R7000 1SVR405612R2000 1SVR405612R3000 1SVR405613R4000 1SVR405613R1000 1SVR405613R6000 1SVR405613R4200 1SVR405613R8000 1SVR405613R8200 1SVR405613R9000 1SVR405613R0000 1SVR405613R5000 1SVR405613R7000 1SVR405613R2000 1SVR405613R3000 Pkg Weight (1 pc.) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) * Note: During the operation of the relay, the temperature of the test button will increase. In order to manually operate the test button, the supply voltage should first be disconnected. The test button is only safe to operate once it has cooled down or by using protective gloves and insulated tools. During operation, the test button should be pressed smoothly and quickly. When the test button is depressed, the n/o contacts will close and remain closed. Once the button is released, the n/o contacts change status and open. A 90 degree rotation of the test button closes and holds the n/o contacts in a closed position. Reverse rotation of the test button will once again change the status of the n/o contacts to their default open position. 398 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M 2CDC 291 002 F0015 -- Ordering details - CR-M range with LED Rated control supply voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Outputs Contact ratings Type Order code 2 c/o (SPDT) 250 V, 12 A 3 c/o (SPDT) 250 V, 10 A 4 c/o (SPDT) 250 V, 6 A CR-M012DC2L CR-M024DC2L CR-M048DC2L CR-M060DC2L CR-M110DC2L CR-M125DC2L CR-M220DC2L CR-M012AC2L CR-M024AC2L CR-M048AC2L CR-M110AC2L CR-M120AC2L CR-M230AC2L CR-M012DC3L CR-M024DC3L CR-M048DC3L CR-M060DC3L CR-M110DC3L CR-M125DC3L CR-M220DC3L CR-M012AC3L CR-M024AC3L CR-M048AC3L CR-M110AC3L CR-M120AC3L CR-M230AC3L CR-M012DC4L CR-M024DC4L CR-M048DC4L CR-M060DC4L CR-M110DC4L CR-M125DC4L CR-M220DC4L CR-M012AC4L CR-M024AC4L CR-M048AC4L CR-M110AC4L CR-M120AC4L CR-M230AC4L 1SVR405611R4100 1SVR405611R1100 1SVR405611R6100 1SVR405611R4300 1SVR405611R8100 1SVR405611R8300 1SVR405611R9100 1SVR405611R0300 1SVR405611R0100 1SVR405611R5100 1SVR405611R7100 1SVR405611R2100 1SVR405611R3100 1SVR405612R4100 1SVR405612R1100 1SVR405612R6100 1SVR405612R4300 1SVR405612R8100 1SVR405612R8300 1SVR405612R9100 1SVR405612R0300 1SVR405612R0100 1SVR405612R5100 1SVR405612R7100 1SVR405612R2100 1SVR405612R3100 1SVR405613R4100 1SVR405613R1100 1SVR405613R6100 1SVR405613R4300 1SVR405613R8100 1SVR405613R8300 1SVR405613R9100 1SVR405613R0300 1SVR405613R0100 1SVR405613R5100 1SVR405613R7100 1SVR405613R2100 1SVR405613R3100 Pkg Weight (1 pc.) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 399 -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M 2CDC 291 002 F0015 -- Ordering details - CR-M range with LED and free-wheeling diode Rated control Outputs supply voltage Contact ratings Type Order code 12 V DC 24 V DC 2 c/o (SPDT) 250 V, 6 A CR-M012DC2LD 1SVR405611R4400 CR-M024DC2LD 1SVR405611R1400 48 V DC CR-M048DC2LD 1SVR405611R6400 110 V DC CR-M110DC2LD 1SVR405611R8400 125 V DC CR-M125DC2LD 1SVR405611R8500 220 V DC CR-M220DC2LD 1SVR405611R9400 12 V DC 24 V DC 3 c/o (SPDT) 250 V, 10 A CR-M012DC3LD 1SVR405612R4400 CR-M024DC3LD 1SVR405612R1400 48 V DC CR-M048DC3LD 1SVR405612R6400 110 V DC CR-M110DC3LD 1SVR405612R8400 125 V DC CR-M125DC3LD 1SVR405612R8500 220 V DC CR-M220DC3LD 1SVR405612R9400 12 VDC 24 V DC 4 c/o (SPDT) 250 V, 6 A CR-M012DC4LD 1SVR405613R4400 CR-M024DC4LD 1SVR405614R1100 48 V DC CR-M048DC4LD 1SVR405613R6400 110 V DC CR-M110DC4LD 1SVR405613R8400 125 V DC CR-M125DC4LD 1SVR405613R8500 220 V DC CR-M220DC4LD 1SVR405613R9400 -- Ordering details - CR-M range with gold contacts Rated control Outputs supply voltage Contact ratings Type Order code 24 V DC 24 V AC 110 V AC 230 V AC 4 c/o (SPDT) 250 V, 6 A CR-M024DC4G CR-M024AC4G CR-M110AC4G CR-M230AC4G 1SVR405618R1000 1SVR405618R0000 1SVR405618R7000 1SVR405618R3000 Pkg Weight (1 pc.) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) Pkg Weight (1 pc.) qty kg (lb) 10 0.033 (0.073) 400 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M 2CDC 291 002 F0015 -- Ordering details CR-M range with gold contacts and LED Rated control Outputs supply voltage Contact Type ratings Order code 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 4 c/o (SPDT) 250 V / 6 A CR-M012DC4LG CR-M024DC4LG CR-M048DC4LG CR-M060DC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG CR-M024AC4LG CR-M048AC4LG CR-M110AC4LG CR-M120AC4LG CR-M230AC4LG 1SVR405618R4100 1SVR405618R1100 1SVR405618R6100 1SVR405618R4300 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 1SVR405618R0100 1SVR405618R5100 1SVR405618R7100 1SVR405618R2100 1SVR405618R3100 Pkg Weight (1 pc.) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) -- Ordering details CR-M range with gold contacts, LED and free-wheeling diode Rated control Outputs Contact Type Order code Pkg supply voltage ratings qty 12 V DC 4 c/o 250 V / 6 CR-M012DC4LDG 1SVR405618R4400 10 24 V DC (SPDT) A CR-M024DC4LDG 1SVR405618R1400 Weight (1 pc.) kg (lb) 0.033 (0.073) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 401 -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M complete version 2CDC291002F0019 -- Ordering details CR-M range complete version Rated control supply voltage Outputs Description Socket type Connec- Type tion terminal Order code Pkg Weight (1 pc.) qty kg (lb) 12 V DC 4 c/o LED red, holder standard goldplated screw CR-M012DC4LDGSS 1SVR405618R4410 10 0.0109 (0.024) 24 V DC 4 c/o Reverse standard polarity protection and free-wheeling diode, LED green, holder screw CR-M024DC4SS42V 1SVR405613R1010 10 0.0109 (0.024) Reverse logical polarity protection and free-wheeling diode, LED green, holder screw CR-M024DC4LS42V 1SVR405613R1011 10 0.0109 (0.024) Reverse logical polarity protection and free-wheeling diode, LED red, holder spring CR-M024DC4LC42 1SVR405613R1012 10 0.0109 (0.024) 24 V DC 4 c/o Reverse standard gold- polarity plated protection and free-wheeling diode, LED green, holder screw CR-M024DC4GSS42V 1SVR405618R1011 10 0.0109 (0.024) Varistor, LED green, holder logical spring CR-M024DC4GLC62CV 1SVR405618R1010 10 0.0109 (0.024) LED, freewheeling diode, holder logical spring CR-M024DC4LGLC22 1SVR405618R1110 10 0.0109 (0.024) LED red, freewheeling diode, holder standard screw CR-M024DC4LDGSS 1SVR405618R1410 10 0.0109 (0.024) 24 V AC 4 c/o Varistor and LED green, holder logical screw CR-M024AC4LS62CV 1SVR405613R0010 10 0.0109 (0.024) 402 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M complete version 2CDC291002F0019 -- Ordering details CR-M range complete version Rated control supply voltage Outputs 230 V AC 4 c/o 230 V AC 4 c/o goldplated Description Socket Connection Type type terminal Varistor, LED green, holder standard screw Varistor, LED green, holder logical screw Diode and LED red, holder logical spring Reverse standard screw polarity protection and free-wheeling diode, LED green, holder LED red, holder logical screw LED red, holder standard screw CR-M230AC4SS92CV CR-M230AC4LS92CV CR-M230AC4LC92 CR-M230AC4GSS92CV CR-M230AC4LGLC CR-M230AC4LGSS Order code Pkg Weight (1 pc.) qty kg (lb) 1SVR405613R3110 10 0.0109 (0.024) 1SVR405613R3011 10 0.0109 (0.024) 1SVR405613R3012 10 0.0109 (0.024) 1SVR405618R3112 10 0.0109 (0.024) 1SVR405618R3110 10 1SVR405618R3111 10 0.0109 (0.024) 0.0109 (0.024) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 403 -- Pluggable interface relays and optocouplers Ordering details CR-M range CR-M2LS CR-M4SS CR-MJ 2CDC 291 005 F0007 2CDC 291 009 F0011 2CDC291042F0004 Standard and logical sockets for CR-M interface relays are suitable for snap-on mounting onto a DIN rail. Optional function modules for the CR-M range are plugged into both standard and logical sockets. -- Ordering details - Sockets* Version Connection terminal Type Logical socket for 2 c/o screw CR-M2LS Logical socket for 3 c/o CR-M3LS Logical socket for 2/4 c/o CR-M4LS Logical socket for 2 c/o spring CR-M2LC Logical socket for 2/4 c/o CR-M4LC Standard socket for 2 c/o screw CR-M2SS Standard socket for 3 c/o CR-M3SS Standard socket for 2/4 c/o CR-M4SS Standard socket for 2 c/o fork type CR-M2SF Standard socket for 2/4 c/o CR-M4SF *All CR-M socket packages include a set of markers. Order code 1SVR405651R1100 1SVR405651R2100 1SVR405651R3100 1SVR405651R1200 1SVR405651R3200 1SVR405651R1000 1SVR405651R2000 1SVR405651R3000 1SVR405651R1300 1SVR405651R3300 Pkg Weight (1 pc.) qty kg (lb) 10 0.055 (0.121) 0.062 (0.137) 0.066 (0.146) 10 0.065 (0.143) 0.066 (0.146) 10 0.066 (0.146) 0.068 (0.150) 0.070 (0.154) 10 0.040 (0.088) 0.048 (0.106) Standard sockets Position of connection terminals: coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket. Logical sockets Position of connection terminals: coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on upper side of the socket. -- Ordering details - Accessories Version Plastic holder for socket Metal holder for socket Jumper bar for sockets with screw connection Marker for CR-M standard sockets Plug for test button replacement Type CR-MH CR-MH1 CR-MJ CR-MM CR-MP Order code 1SVR405659R1000 1SVR405659R1100 1SVR405658R6000 1SVR405658R1000 1SVR405658R2000 Pkg Weight (1 pc.) qty kg (lb) 10 0.003 (0.007) 10 0.0005 (0.001) 10 0.029 (0.064) 10 0.0005 (0.001) 100 0.001 (0.002) 404 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-P/M function modules CR-P/M ... 2CDC 291 005 S0011 -- Ordering details - Diode - Reverse polarity protection / free-wheeling diode Rated control supply voltage Us 6-220 V DC Version A1+, A2- Type CR-P/M 22 Order code Pkg qty 1SVR405651R0000 10 Weight (1 pc.) kg (lb) 0.003 (0.007) -- Ordering details - Diode and LED - Reverse polarity protection / free-wheeling diode and LED to indicate energized coil Rated control supply voltage Us 6-24 V DC 6-24 V DC 24-60 V DC 24-60 V DC 110 V DC 110 V DC Version red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2- Type Order code Pkg qty CR-P/M 42 1SVR405652R0000 10 CR-P/M 42 V 1SVR405652R1000 CR-P/M 42 B 1SVR405652R4000 CR-P/M 42 BV 1SVR405652R4100 CR-P/M 42 C 1SVR405652R9000 CR-P/M 42 CV 1SVR405652R9100 Weight (1 pc.) kg (lb) 0.003 (0.007) -- Ordering details - RC element - Spark quenching Rated control supply voltage Us Version Type 6-24 V AC/DC 24-60 V AC/DC 110-230 V AC/DC CR-P/M 52B CR-P/M 52D CR-P/M 52C Order code Pkg qty 1SVR405653R0000 10 1SVR405653R4000 1SVR405653R1000 Weight (1 pc.) kg (lb) 0.003 (0.007) -- Ordering details - Diode and LED - LED to indicate energized coil Rated control supply voltage Us 6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC Version Type Order code Pkg qty red, for DC: A1+, A2- CR-P/M 62 1SVR405654R0000 10 green, for DC: A1+, A2- CR-P/M 62 V 1SVR405654R1000 red, for DC: A1+, A2- CR-P/M 62 E 1SVR405654R4000 green, for DC: A1+, A2- CR-P/M 62 EV 1SVR405654R4100 red, for DC: A1+, A2- CR-P/M 92 1SVR405654R0100 green, for DC: A1+, A2- CR-P/M 92 V 1SVR405654R1100 Weight (1 pc.) kg (lb) 0.003 (0.007) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 405 -- Pluggable interface relays and optocouplers Ordering details CR-P/M function modules CR-P/M ... 2CDC 291 005 S0011 -- Ordering details - Varistor and LED - Overvoltage protection and LED to indicate energized coil Rated control supply voltage Us 6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC Version Type Order code Pkg qty red, for DC: A1+, A2- CR-P/M 62 C 1SVR405655R0000 10 green, for DC: A1+, A2- CR-P/M 62 CV 1SVR405655R1000 red, for DC: A1+, A2- CR-P/M 62 D 1SVR405655R4000 green, for DC: A1+, A2- CR-P/M 62 DV 1SVR405655R4100 red, for DC: A1+, A2- CR-P/M 92 C 1SVR405655R0100 green, for DC: A1+, A2- CR-P/M 92 CV 1SVR405655R1100 Weight (1 pc.) kg (lb) 0.003 (0.007) -- Ordering details - Varistor - Overvoltage protection Rated control supply voltage Us Version Type 24 V AC 115 V AC 230 V AC CR-P/M 72 CR-P/M 72 A CR-P/M 82 Order code Pkg qty 1SVR405656R0000 10 1SVR405656R1000 1SVR405656R2000 Weight (1 pc.) kg (lb) 0.002 (0.004) 406 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-U range CR-U 2CDC 291 047 F0004 The CR-U range offers up to 3 change over contacts in single relay. The integrated LED and test button* allow for easy testing and commissioning. This robust range of relays are available at a wide range of different coil voltages and are accompanied by a wide variety of function modules. -- Ordering details - CR-U range without LED Rated control Outputs supply voltage Contact ratings 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 2 c/o (SPDT) 250 V, 10 A 3 c/o (SPDT) 250 V, 10 A Type Order code CR-U012DC2 CR-U024DC2 CR-U048DC2 CR-U110DC2 CR-U220DC2 CR-U024AC2 CR-U048AC2 CR-U110AC2 CR-U120AC2 CR-U230AC2 CR-U012DC3 CR-U024DC3 CR-U048DC3 CR-U110DC3 CR-U125DC3 CR-U220DC3 CR-U024AC3 CR-U048AC3 CR-U060AC3 CR-U110AC3 CR-U120AC3 CR-U230AC3 1SVR405621R4000 1SVR405621R1000 1SVR405621R6000 1SVR405621R8000 1SVR405621R9000 1SVR405621R0000 1SVR405621R5000 1SVR405621R7000 1SVR405621R2000 1SVR405621R3000 1SVR405622R4000 1SVR405622R1000 1SVR405622R6000 1SVR405622R8000 1SVR405622R8200 1SVR405622R9000 1SVR405622R0000 1SVR405622R5000 1SVR405622R5200 1SVR405622R7000 1SVR405622R2000 1SVR405622R3000 Pkg Weight (1 pc.) qty kg (lb) 10 0.083 (0.183) 10 0.083 (0.183) * Note: During the operation of the relay, the temperature of the test button will increase. In order to manually operate the test botton, the supply voltage should first be disconnected. The test button is only safe to operate once it has cooled down or by using protective gloves and insulated tools. During operation, the test button should be pressed smoothly and quickly. When the test button is depressed, the n/o contacts will close and remain closed. Once the button is released, the n/o contacts change status and open. A 90 degree rotation of the test button closes and holds the n/o contacts in a closed position. Reverse rotation of the test button will once again change the status of the n/o contacts to their default open position. -- Ordering details - CR-U range with LED Rated control Outputs supply voltage Contact ratings 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 2 c/o (SPDT) 250 V, 10 A Type Order code CR-U012DC2L 1SVR405621R4100 CR-U024DC2L 1SVR405621R1100 CR-U048DC2L 1SVR405621R6100 CR-U110DC2L 1SVR405621R8100 CR-U220DC2L 1SVR405621R9100 CR-U012AC2L 1SVR405621R0300 CR-U024AC2L 1SVR405621R0100 CR-U048AC2L 1SVR405621R5100 CR-U110AC2L 1SVR405621R7100 CR-U120AC2L 1SVR405621R2100 CR-U230AC2L 1SVR405621R3100 Pkg Weight (1 pc.) qty kg (lb) 10 0.083 (0.183) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 407 -- Pluggable interface relays and optocouplers Ordering details CR-U range CR-U CR-U2S 2CDC 291 007 S0011 2CDC 291 047 F0004 -- Ordering details - CR-U range with LED Rated control Outputs supply voltage Contact ratings 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 3 c/o (SPDT) 250 V, 10 A Type Order code CR-U012DC3L 1SVR405622R4100 CR-U024DC3L 1SVR405622R1100 CR-U048DC3L 1SVR405622R6100 CR-U110DC3L 1SVR405622R8100 CR-U220DC3L 1SVR405622R9100 CR-U012AC3L 1SVR405622R0300 CR-U024AC3L 1SVR405622R0100 CR-U048AC3L 1SVR405622R5100 CR-U110AC3L 1SVR405622R7100 CR-U120AC3L 1SVR405622R2100 CR-U230AC3L 1SVR405622R3100 Pkg Weight (1 pc.) qty kg (lb) 10 0.083 (0.183) -- Ordering details - CR-U range with LED and free-wheeling diode Rated control Outputs supply voltage Contact ratings Type Order code 12 V DC 24 V DC 2 c/o (SPDT) 250 V, 10 A CR-U012DC2LD CR-U024DC2LD 1SVR405621R4400 1SVR405621R1400 48 V DC CR-U048DC2LD 1SVR405621R6400 110 V DC CR-U110DC2LD 1SVR405621R8400 12 V DC 24 V DC 3 c/o (SPDT) CR-U012DC3LD CR-U024DC3LD 1SVR405622R4400 1SVR405623R1100 48 V DC CR-U048DC3LD 1SVR405622R6400 110 V DC CR-U110DC3LD 1SVR405622R8400 Pkg Weight (1 pc.) qty kg (lb) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) The sockets for CR-U interface relays have screw connection terminals and are suitable for snap-on mounting onto a DIN rail. Optional function modules for the CR-U range may only be plugged into compatible standard sockets. -- Ordering details - Sockets and Accessories Version Type Socket for 2 c/o and function module Socket for 3 c/o and function module Socket for 3 c/o Small socket for 2 c/o Small socket for 3 c/o Metal holder for socket CR-U2S CR-U3S CR-U3E CR-U2SM CR-U3SM CR-UH Order code 1SVR405670R0000 1SVR405660R0000 1SVR405660R0100 1SVR405670R1100 1SVR405660R1100 1SVR405669R0000 Pkg Weight (1 pc.) qty kg 10 0.065 0.065 0.065 0.054 0.058 0.001 CR-U sockets Position of connection terminals: coil connection (A1-A2) on lower side of socket, contact connections (n/o and n/c contacts) on the lower and upper side of socket. 408 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Ordering details CR-U function modules CR-U... 2CDC 291 004 S0011 CR-U function modules are compatible with the CR-U2S and CR-U3S sockets only. -- Diode - Reverse polarity protection / free-wheeling diode Rated control supply voltage 6-220 V DC Version A1+, A2- Type CR-U 21 Order code Pkg qty 1SVR405661R0000 10 Weight (1 pc.) kg (lb) 0.007 (0.015) -- Diode and LED - Reverse polarity protection / free-wheeling diode and LED to indicate energized coil Rated control supply voltage 6-24 V DC 6-24 V DC 24-60 V DC 24-60 V DC 110 V DC 110 V DC Version red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2- Type CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV Order code Pkg qty 1SVR405662R0000 10 1SVR405662R1000 1SVR405662R4000 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 Weight (1 pc.) kg (lb) 0.007 (0.015) -- RC element - Spark quenching Rated control supply voltage Version 6-24 V AC/DC 24-60 V AC/DC 110 -230 V AC/DC Type CR-U 51B CR-U 51D CR-U 51C Order code Pkg qty 1SVR405663R0000 10 1SVR405663R4000 1SVR405663R1000 Weight (1 pc.) kg (lb) 0.007 (0.015) -- Diode and LED - LED to indicate energized coil Rated control supply voltage Version Type 6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC: A1+, A2- CR-U 61 CR-U 61V CR-U 61E CR-U 61EV CR-U 91 CR-U 91V Order code Pkg qty 1SVR405664R0000 10 1SVR405664R1000 1SVR405664R4000 1SVR405664R4100 1SVR405664R0100 1SVR405664R1100 Weight (1 pc.) kg (lb) 0.007 (0.015) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 409 -- Pluggable interface relays and optocouplers Ordering details CR-U function modules CR-U... CR-U T 2CDC 291 032 F0005 2CDC 291 004 S0011 -- Varistor and LED - Overvoltage protection and LED to indicate energized coil Rated control supply voltage Version 6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2- Type CR-U 61C CR-U 61CV CR-U 61D CR-U 61DV CR-U 91C CR-U 91CV Order code Pkg qty 1SVR405665R0000 10 1SVR405665R1000 1SVR405665R4000 1SVR405665R4100 1SVR405665R0100 1SVR405665R1100 Weight (1 pc.) kg (lb) 0.007 (0.015) -- Varistor - Overvoltage protection Rated control supply voltage Version 24 V AC 115 V AC 230 V AC -- Multi-function time module* Rated control supply voltage Version 24-240 V AC/DC green LED Type CR-U 71 CR-U 71A CR-U 81 Type CR-U T * For more details, refer to the CR-U T datasheet. Order code 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 Pkg Weight (1 pc.) qty kg (lb) 10 0.007 (0.015) Order code 1SVR405667R0000 Pkg Weight (1 pc.) qty kg (lb) 10 0.014 (0.031) 410 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data - CR-S interface relays Input circuit CR-S005VDC1R(G) CR-S012VDC1R(G) CR-S024VDC1R(G) CR-S048VDC1R(G) CR-S060VDC1R(G) Rated control supply voltage Us 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC Make voltage (at 23 °C) 3.75 V DC 9 V DC 18 V DC 36 V DC 45 V DC Maximum voltage (at 55 °C) 7.5 V DC 18 V DC 36 V DC 72 V DC 90 V DC Break voltage Rated power 0.25 V DC 0.6 V DC 1.2 V DC 2.4 V DC 3 V DC 170 mW 170 mW 170 mW 210 mW 210 mW Coil resistance (at 23 °C) 147 848 3390 10600 16600 Tolerance of coil resistance ± 10 % ± 10 % ± 15 % ± 15 % ± 15 % Output circuits Output circuit(s) Kind of output Contact material Rated operational voltage Ue (IEC/EN 60947-1) Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current Ith Rated operational current (IEC/EN 60947-5-1) AC rating (UL 508; NEMA ICS-5) DC rating (UL 508; NEMA ICS-5) Maximum making (inrush) current Minimum switching power Maximum switching (breaking) power Contact resistance Maximum operating frequency Mechanical lifetime Electrical lifetime Response time Release time Isolation data Rated insulation voltage Rated impulse withstand voltage Uimp Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions Mounting Mounting position Degree of protection 11-12/14 1 c/o (SPDT) AgSnO2 or AgSnO2/Au 250 V AC 5 V at 100 mA (AgSnO2) / 5 V at 12 mA (AgSnO2/Au) 400 V AC / 250 V DC 10 mA at 10 V (AgSnO2) / 3 mA at 20 V (AgSnO2/Au) 5 A AC12 (resistive) 230 V 6 A AC15 (inductive) 230 V 1.5 A AC15 (inductive) 120 V 3 A DC12 (resistive) 24 V 6 A DC13 (inductive) 24 V 1 A DC13 (inductive) 120 V 0.22 A DC13 (inductive) 250 V 0.11 A utilization category (pilot duty) B300 (contact rating code designation) utilization category (pilot duty) R300 (contact rating code designation) 15 A, 240 V AC 100 mA/12 V (AgSnO2) / 50 mW (AgSnO2/Au) AC1 (resistive) 1500 VA, 250 V AC 100 m (at 1 A/ 6 V DC) rated load AC1 360 switching cycles/h without load 18000 switching cycles/h 1 x 107 switching cycles AC1 (resistive) (n/c) 3 x 104 switching cycles (at +85 °C) (n/o) 1 x 104 switching cycles (at +85 °C) 8 ms 4 ms 250 V AC between coil and contacts 4000 V 1 min between open contacts 1000 V 1 min between coil and contacts 5.5 mm (0.217 in) between coil and contacts 8 mm (0.315 in) III 2 see 'Dimensional drawings' on socket any RT II and RT III ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 411 -- Pluggable interface relays and optocouplers Technical data - CR-S interface relays and CR-S optocouplers Electrical connection Connection Environmental data Ambient temperature range Vibration resistance (10-150 Hz) Shock resistance Standards/directives Standards RoHS Directive by socket operation -40...+85 °C storage -40...+85 °C n/o contact 10 Hz to 55 Hz 1 mm DA n/c contact 10 Hz to 55 Hz 1 mm DA n/o contact function 49 m/s2 / destructive 980 m/s2 n/c contact function 49 m/s2 / destructive 980 m/s2 IEC/EN 61810-1 2011/65/EU -- Technical data - CR-S optocouplers Input circuit Input resistance Rated control voltage Pull-in voltage Maximum input voltage Nominal input current Input power Typical switching-on time Typical switch-off time Output circuits Output circuit(s) Kind of output Rated operational voltage Maximum switching voltage Minimum switching current Maximum switching current continuously Leakage current at maximum switching voltage Voltage drop at rated current Isolation data Rated insulation voltage Insulation class Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions Weight Mounting Environmental data Ambient temperature Standards / Directives Standards EMC Directive RoHS Directive * The output circuit should not exceed 30 m. CR-S024VDC1TRA 3400 Ohm 24 V DC* 15 V DC 30 V DC 7 mA 168 mW < 40 ms < 600 ms CR-S024VDC1MOS < 60 ms < 600 ms 11 (13+) - 14 Transistor 48 V DC 48 V DC 50 mA 100 mA <1 mA < 120 mV DC 11 (13+) - 14 MOS-FET 24 V DC 24 V DC 50 mA 2 A <1 mA < 120 mV DC input/output 2.5 kV 2 input/output 14 mm input/output 14 mm III 2 see 'Dimensional drawings' 3.5 g (0.007 lb) on socket operation -30...+80 °C storage -40...+100 °C IEC/EN 62314 2014/30/EN 2011/65/EN CR-S024VDC1TRI < 1/2 cycle < 1/2 cycle 11 (13+) - 14 Triac 240 V AC 275 V AC 22 mA 2 A < 1.5 mA < 1.6 V AC 412 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data - CR-S sockets Input circuit CR-S 6-24 V CR-S 12-24 V CR-S 48-60 V CR-S 110-125 V Rated control supply voltage Us Rated control supply voltage Us tolerance Typical current 6-24 V DC (0.8-1.2) Un 11-29 mA 12-24 V AC/DC* (0.8-1.1) Un 11-16 mA 48-60 V AC/DC 3.6-4.5 mA 110-125 V AC/DC 3.6 mA Response time 8 ms Release time 4 ms Status device green LED Protective circuit yes Output circuits Output circuit(s) 11-12/14 Number of poles 1 Rated voltage 250 V AC Rated current 6 A General data for CR-S with screw connection terminal Dimensions see 'Dimensional drawings' Degree of protection (EN 60529) Degree of protection (EN 60529) IP20 (terminals) Temperature range operation -40...+70 °C -40...+55 °C storage -40...+85 °C Connection type Screw Maximum number of wires per connection terminal 2 Connecting capacity rigid 2 x 0.5 - 1.5 mm² (2 x 20 - 16 AWG) fine-strand with wire end ferule 2 x 0.5 - 1 mm² (2 x 20 - 18 AWG) Tightening torque 0.5 Nm (4.426 lb.in) Stripping length 7 mm (0.28 in) Minimum clamping force for fine-strand wire with 0.2 mm² 10 N with 1.5 mm² 40 N Mounting (IEC/EN 60715) DIN rail Material socket PA6 +GF-V2 contacts CuZn36 contact surface 3 Ni/Sn terminals CuZn40, 3 Ni combi screw M3 Fe General data for CR-S with spring connection terminal Dimensions without holder (L x W x H) see 'Dimensional drawings' Degree of protection (EN 60529) Degree of protection (EN 60529) IP20 (terminals) Temperature range operation -40...+70 °C -40...+55 °C storage -40...+85 °C Connection type Spring Maximum number of wires per connection terminal 1 Connecting capacity 0.75 - 2.5 mm2 (20 - 14 AWG) rigid, fine-strand and with wire end ferrule Stripping length 7 mm (0.28 in) Mounting (IEC/EN 60715) DIN rail Material socket PA6 +GF-V2 contacts CuZn36 contact surface 3 Ni/Sn spring terminals SUS301 Isolation data Isolation between coil and contacts 5000 V AC Resistance to shock coil to contact 1000 M Clearance and creepage distance IEC/EN 61984 Standards / Directives Standard IEC/EN 61984 Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU CR-S 220-240 V 220-240 V AC/DC 3.6 mA * In combination with optocouplers, only DC supply is allowed ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 413 -- Pluggable interface relays and optocouplers Technical data - CR-S jumper bars Rated operational voltage / current CR-SJB20-BLUE Rated operational voltage 250 V AC Rated operational current 36 A Electrical connection Jumper bar cross section 123.2 mm (4.850 in) Step distance 6.3 mm (0.248 in) Rail length with isolation 16.7 mm (0.657 in) without isolation 6.7 mm (0.264 in) Stripping length of a connection wire that is used in combination with a jumper bar 7 mm (0.276 in) Environmental data Ambient temperature range operation -40 ... +70 °C General data Material of rail Cu Number of pins 20 Flammability V0 CR-SJB20-RED CR-SJB20-BLACK 414 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data CR-P, CR-M, CR-U -- Input circuit - coil data CR-P range Rated control supply voltage US Rated frequency Make voltage Maximum (at 20 °C) voltage (at 55 °C) Break voltage DC coils AC coils 12 V DC 24 V DC 48 V DC 110 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC CR-P optocouplers range Input circuit Input resistance Rated control voltage Pull-in voltage Maximum input voltage Nominal input current Input power Typical switching-on time Typical switch-off time 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 8.4 V DC 16.8 V DC 33.6 V DC 77 V DC 19.2 V AC 38.4 V AC 88 V AC 96 V AC 184 V AC 30.6 V DC 61.2 V DC 122.4 V DC 280 V DC 28.8 V AC 57.6 V AC 132 V AC 144 V AC 276 V AC 0.1 US 0.1 US 0.1 US 0.1 US 0.15 US 0.15 US 0.15 US 0.15 US 0.15 US CR-P024MOS1 2200 24 V DC 10 V DC 32 V DC 10 mA 260 mW 50 ms 250 ms CR-M range Rated control supply voltage US Rated frequency Make voltage Maximum (at 20 °C) voltage (at 55 °C) Break voltage DC coils AC coils 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 9.6 V DC 19.2 DC 38.4 V DC 48 V DC 88 V DC 100 V DC 176 V DC 19.2 V AC 38.4 V AC 48 V AC 88 V AC 96 V AC 184 V AC 13.2 V DC 26.4 V DC 52.8 V DC 66 V DC 121 V DC 137.5 V DC 242 V DC 26.4 V AC 52.8 V AC 66 V AC 121 V AC 132 V AC 253 V AC 0.1 US 0.1 US 0.1 US 0.1 US 0.1 US 0.1 US 0.1 US 0.2 US 0.2 US 0.2 US 0.2 US 0.2 US 0.2 US Rated power Coil resistance (at 20 °C) Tolerance of coil resistance 0.4-0.48 W 0.4-0.48 W 0.4-0.48 W 0.4-0.48 W 0.75 VA 0.75 VA 0.75 VA 0.75 VA 0.75 VA 360 1440 5700 25200 400 1550 8900 10200 38500 ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% CR-P024TRI1 1950 24 V DC 10 V DC 32 V DC 12 mA 295 mW < 1/2 cycle < 1/2 cycle Rated power Coil resistance (at 20 °C) Tolerance of coil resistance 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 1.6 VA 1.6 VA 1.6 VA 1.6 VA 1.6 VA 1.6 VA 160 640 2600 4000 13600 16000 54000 158 640 930 3450 3770 16100 ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 415 -- Pluggable interface relays and optocouplers Technical data CR-P, CR-M, CR-U CR-U range Rated control supply voltage US Rated frequency Make voltage Maximum (at 20 °C) voltage (at 55 °C) Break voltage DC coils AC coils 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 9.6 V DC 19.2 V DC 38.4 V DC 88.0 V DC 100 V DC 176.0 V DC 19.2 V AC 38.4 V AC 48.0 V AC 88.0 V AC 96.0 V AC 184.0 V AC 13.2 V DC 26.4 V DC 52.8 V DC 121.0 V DC 137.5 V DC 242.0 V DC 26.4 V AC 52.8 V AC 66.0 V AC 121.0 V AC 132.0 V AC 253.0 V AC 0.1 US 0.1 US 0.1 US 0.1 US 0.1 US 0.1 US 0.15 US 0.15 US 0.15 US 0.15 US 0.15 US 0.15 US Rated power Coil resistance (at 20 °C) Tolerance of coil resistance 1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 110 430 1750 9200 11000 37000 75 305 475 1700 1910 7080 ± 10 % ± 10 % ± 10 % ±10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % ± 10 % 416 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data CR-P, CR-M, CR-U Type CR-P...1 CR-P...2 CR-M...2 CR-M...3 CR-M...4 CR-U...2 CR-U...3 Output circuit(s) 11-12/14 11-12/14 21-22/24 11-12/14 21-22/24 11-12/14 21-22/24 31-32/34 11-12/14 21-22/24 31-32/34 41-42/44 11-12/14 31-32/34 11-12/14 21-22/24 31-32/34 Kind of output Relay, 1 c/o Relay, 2 c/o Relay, 2 c/o Relay, 3 c/o Relay, 4 c/o Relay, 2 c/o Relay, 3 c/o Contact material AgNi AgNi AgNi/Au 5 µm AgNi AgNi AgNi AgNi/Au 5 µm AgNi Rated operational voltage Ue (VDE 0110, IEC 60947-1) 250 V Minimum switching voltage 5 V 10 V (AgNi); 5 V (AgNi/Au) 10 V Maximum switching voltage DC 300 V DC 250 V DC AC 440 V AC 250 V AC 440 V AC Minimum switching current 5 mA (AgNi), 2 mA (AgNi/Au) 5 mA (AgNi) 5 mA (AgNi) 2 mA (AgNi/Au) 5 mA Rated free air thermal current Ith 16 A Rated AC-12 (resistive) 230 V 16 A operational current (IEC 60947-5-1) AC-15 (inductive) 230 V 1.5 A AC-15 (inductive) 120 V 3 A DC-12 (resistive) 24 V 16 A 8 A 8 A 1.5 A 8 A 12 A 12 A 1.5 A 12 A 10 A 10 A 1.5 A 10 A 6 A 6 A 1 A 1.5 A 6 A 10 A 10 A 1.5 A 3 A 10 A DC-13 (inductive) 24 V 2.5 A 2 A 2.5 A 2.5 A 2 A 2 A DC-13 (inductive) 120 V 0.22 A DC-13 (inductive) 250 V 0.1 A AC rating (UL 508) utilization category (pilot B300 duty) (contact rating code designation) B300 B300 max. rated operational 300 V AC voltage 300 V AC 300 V AC max. continuous 5 A thermal current at utilization category 5 A 5 A 2.5 A 5 A max. making / breaking 3600 / 360 VA apparent power at utilization category 3600 / 360 VA 1800 / 180 VA 3600/360 VA utilization category 16 A, (resistive) 250 V AC (CSA22.2 No.14....) 8 A, 250 V AC 10 A, 6 A, 250 V AC 5 A, 250 V AC 10 A, 250 V AC 250 V AC 10 A, 10 A, (resistive + single-phase) 12 A,150 V AC 150 V AC 150 V AC DC rating * (UL 508; NEMA ICS-5) utilization category R300 (pilot duty) (contact rating code designation) max. rated operational 300 V DC voltage max. continuous 1 A thermal current at utilization category max. making / breaking 28 VA apparent power at utilization category utilization category (resistive) (CSA22.2 No.14....) 10 A, 24 V DC - 10 A, 28 V DC Maximum making (inrush) current 30 A 15 A 24 A 20 A 12 A 20 A Minimum switching power 0.3 W (AgNi), 0.05 W (AgNi/Au) 0.3 W (AgNi), 0.1 W (AgNi/Au) 0.3 W Maximum switching (breaking) AC1 4000 VA power (resistive) 2000 VA 3000 VA 2500 VA 1500 VA 2500 VA Contact resistance 100 m Maximum operating frequency rated load 600 switching cycles/h AC-1 1200 switching cycles/h without 72000 switching cycles/h load 18000 switching cycles/h 12000 switching cycles/h ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 417 -- Pluggable interface relays and optocouplers Technical data CR-P, CR-M, CR-U Type Mechanical lifetime Electrical lifetime CR-P...1 CR-P...2 > 3 x 107 switching cycles electrical > 0.7 x 105 AC1 switching (resistive) cycles (16 A, 250 V) > 105 switching cycles (8 A, 250 V) CR-M...2 CR-M...3 > 2 x 107 switching cycles > 105 switching cycles (12 A, 250 V) (10 A, 250 V) CR-M...4 (6 A, 250 V) cos see reduction factor F Response time typ. 7 ms Release time typ. 3 ms Isolation data Rated insulation voltage 400 V AC Insulation class (In accordance to VDE 0110b) C250 / B400 Rated impulse withstand voltage Uimp between coil and contacts 5 kV between open contacts 1 kV between c/o (SPDT) contacts 2.5 kV Clearance between coil and contacts 10 mm Creepage distance between coil and contacts 10 mm Overvoltage category III Pollution degree 3 General data Dimensions see 'Dimensional drawings' Mounting on socket (see accessories) Mounting position any Degree of protection IP 67 Electrical connection Connection by socket Environmental data Ambient temperature range operation DC: -40...+85 °; AC: -40...+70 °C storage -40 ... +85 °C Vibration resistance 10-150 Hz n/o contact 10 g n/c contact 10 g 5 g Shock resistance n/o contact 30 g 20 g n/c contact 30 g 20 g Standards / Directives Standards IEC/EN 61810-1 Low Voltage Directive - RoHS Directive 2011/65/EU typ. 13 ms (DC), 10 ms (AC) typ. 3 ms (DC), 8 ms (AC) 250 V AC C250 / B250 2.5 kV 1.5 kV 2.5 kV 2.5 mm 4 mm III 3 2 kV 1.6 mm 3.2 mm II 2 IP 40 DC: -40...+70 °; AC: -40...+55 °C 5 g 5 g 10 g 5 g 2014/35/EU CR-U...2 CR-U...3 > 105 switching cycles (12 A, 250 V) typ. 18 ms (DC), 12 ms (AC) typ. 7 ms (DC), 10 ms (AC) C250 2 kV 3 mm 4.2 mm III 3 5 g 5 g 10 g 10 g * These ratings are based on different type tests which are not covered by the cULus or CSA approvals. 418 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data CR-P optocouplers Output circuits Output circuit(s) Kind of output Rated operational voltage Maximum switching voltage Minimum switching current Maximum switching current continuously Leakage current at maximum switching voltage Voltage drop at rated current Isolation data Rated insulation voltage Insulation class Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions Weight Mounting Environmental data Ambient temperature Standards / Directives Standards EMC Directive RoHS Directive CR-P024MOS1 11 (13+) - 14 MOS-FET 24 V DC 35 V DC 1 mA 5 A 10 uA 300 mV input/output 2.5 kV 2 input/output 19 mm input/output 19 mm III 2 see 'Dimensional drawings' 11 g (0.618 lbs) on socket operational -20...+80 °C storage -40...+100 °C IEC/EN 62314 2014/30/EU 2011/65/EU CR-P024TRI1 11 (13+) - 14 Triac 240 V AC 275 V AC 50 mA 3,5 A 1 mA 1.1 V 2.5 kV 2 19 mm 19 mm III 2 11 g (0.618 lbs) on socket -20...+80 °C -40...+100 °C IEC/EN 62314 2014/30/EU 2011/65/EU ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 419 -- Pluggable interface relays and optocouplers Technical data - CR-P and CR-M sockets Output circuits CR-PLS CR-PLSx CR-PSS CR-PLC CR-MxLS CR-MxSS CR-MxSF CR-MxLC Output circuit(s) 11-12/14, 21-22/24 11-12/14, 21-22/24, ... Number of poles 2 2, 3 or 4 2 or 4 Rated voltage 250 V AC/DC 300 V AC/DC 250 V AC/DC 250 V AC/DC 300 V AC/DC Rated current 2 x 10 A1) 2 x 12 A1) 2 x 10 A1) 7 A 10 A General data Dimensions without holder and module (L x W x H) 76 x 15.8 x 62 78.5 x 15.5 x 76 x 15.8 x mm 61 mm 42.8 mm (2.992 x (3.011 x 0.610 (2.992 x 0.622 x x 2.402 in) 0.622 x 2.441 in) 1.685 in) 97.5 x 16.3 x 45.2 mm (3.839 x 0.642 x 1.780 in) 75 x 27.2 x 60.8 mm (2.952 x 1.071 x 2.394 in) 75.2 x 27.2 x 42.6 mm (2.961 x 1.071 x 1.677 in) 66.7 x 30.3 x 95 x 31 x 42.5 29 mm (2.626 mm x 1.193 x (3.74 x 1.22 x 1.142 in) 1.67 in) Degree of protection terminals IP 20 B (EN 60529) Temperature range operation -40...+70 °C storage -40...+70 °C -40...+85 °C -40...+85 °C -40...+70 °C -40...+70 °C -40...+70 °C -40...+70 °C -25...+85 °C Connection type screw connection spring screw connection connection fork type screw spring connection Maximum number 2 of wires per connecting terminal 2 (one per 2 connection point) - 2 (one per connection point) Connecting capacity rigid 2 x 0.5 - 2.5 mm2 (2 x 20 - 14 AWG) fine-strand 2 x 0.2 - 1.5 mm2 (2 x 24 - 16 AWG) 2 x 0.5 - 2.5 mm2 (2 x 20 - 14 AWG) 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) with wire end 2 x ferrule 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) 2 x 1.5 mm2 (2 x 16 AWG) 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) 2 x 1.5 mm2 (2 x 16 AWG) 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) 2 x 1.5 mm2 (2 x 16 AWG) Stripping length 7 mm (0.28 in) 11 mm (0.43 in) 7 mm (0.28 in) 10 mm (0.39 in) Tightening torque 0.6 Nm 0.8 Nm 0.6 Nm 0.6 Nm (5.31 lb.in) Maximum with 0,2 mm2 - - - 10 N - - - 10 N clamping with 1,5 mm2 - - - 40 N - - - 40 N force with wire end - - - - > 40 N ferrule Mounting DIN rail (IEC/EN 60715) Material socket PA 6+GF - V2 PA 6+GF - V2 contacts CuZn33 CuZn33 contact surface 5 Ni 5 tinned 5 Ni 5 Ni 6 Ni 5 tinned terminals 8 Ni 8 galvanized 8 Ni XCrNi Steel 8 Ni CCSC combi screw M3 8.8 Steel, 5 Ni - 8.8 Steel, 5 Ni - Isolation data Insulation voltage > 5 kV > 3 kV > 5 kV > 3 kV > 4 kV Isolation between coil and contacts IEC/EN 61984 Clearance and creepage distance IEC/EN 61984 Standards / Directives Standards IEC/EN 61984 Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU 1) Loads >10 A ( >12 A for CR-PLSx) require jumpering of terminal 11 with 21, 12 with 22, and 14 with 24 420 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data - CR-P and CR-M jumper bars Rated operational voltage / Rated current CR-PJ Rated operational voltage (VDE 0660 / part 500) 400 V Rated current (VDE 0660 / part 500) 25 A Electrical connection Bus bar diameter 6 mm² (0.0093 in²) Step distance 15.5 mm (0.610 in) Rail length with isolation 150 mm (5.906 in) without isolation 141.5 mm (5.571 in) Stripping length of a connection wire that is used in combination with a jumper bar 6 mm (0.236 in) Environmental data Ambient temperature range operation -40... +55 °C Isolation data Rated impulse withstand voltage Uimp (VDE 0660 / part 500) 4 kV Overvoltage category (IEC/EN 60664) III Polution degree (IEC/EN 60664) 2 General data Material of rail E-Cu-F25 Type of rail pin type Number of pins 10 Number of phases 1 Color of insulating material RAL 7035 Flammability (UL 94) V0 CR-MJ 27.2 mm (1.071 in) 255 mm (10.039 in) 245 mm (9.646 in) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 421 -- Pluggable interface relays and optocouplers Technical data - CR-P and CR-M function modules CR-P/M 22 Type Version Function Control supply voltage Component data Polarized Material CR-P/M 42 Type Version Function Control supply voltage Component data Polarized Material CR-P/M 52 Type Version Function Control supply voltage Component data Polarized Material CR-P/M 62 Type Version Control supply voltage Component data Polarized Material CR-P/M 72, 82 Type Version Function Control supply voltage Component data Polarized Material CR-P/M 92 Type Version Control supply voltage Component data Polarized Material Standards / Directives Standards Low Voltage Directive RoHS Directive CR-P/M 22 Diode Reverse polarity protection 6-220 V DC diode 1 A, 1000 V yes (A1+, A2-) enclosure / base PA6 + GF V2 CR-P/M 42 CR-P/M 42V CR-P/M 42B CR-P/M 42BV CR-P/M 42C CR-P/M 42CV Diode and LED Reverse polarity protection, applied supply voltage indicated via LED 6-24 V DC 24-60 V DC 110 V DC diode 1 A, 1000 V LED red green red green red green resistance 3 k, 0.25 W 15 k, 0.25 W 200 k, 0.25 W yes (A1+, A2-) enclosure / base PA6 + GF V2 CR-P/M 52B RC element Arc elimination 6-24 V AC/DC capacitor 0.1 µF, 63 V DC resistance 10 , 0.25 W no enclosure / base PA6 + GF V2 CR-P/M 52D 24-60 V AC/DC 0.1 µF, 100 V DC 47 , 0.25 W CR-P/M 52C 110-230 V AC/DC 0.082 µF, 400 V DC 100 , 0.25 W CR-P/M 62 CR-P/M 62V CR-P/M 62E CR-P/M 62EV Diode and LED 6-24 V AC/DC 24-60 V AC/DC diode 1 A, 1000 V LED red green red green varistor 25 V AC 75 V AC resistance 3 k, 0.25 W 15 k, 0.25 W AC: no, DC: yes (A1+, A2-) enclosure / base PA6 + GF V2 CR-P/M 62C CR-P/M 62CV Varistor and LED 6-24 V AC/DC red green 25 V AC 3 k, 0.25 W CR-P/M 62D CR-P/M 62DV 24-60 V AC/DC red green 75 V AC 15 k, 0.25 W CR-P/M 72 Varistor Overvoltage protection 24 V AC varistor 25 V AC no enclosure / base PA6 + GF V2 CR-P/M 72A 115 V AC 115 V AC CR-P/M 82 230 V AC 275 V AC CR-P/M 92 CR-P/M 92V Diode and LED 110-230 V AC / 110 V DC diode 1 A, 1000 V LED red green varistor 275 V AC resistance 120 k, 0.25 W AC: no, DC: yes (A1+, A2-) enclosure / base PA6 + GF V2 CR-P/M 92C Varistor and LED CR-P/M 92CV red green IEC/EN 61984 2014/35/EU 2011/65/EU 422 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical data - CR-U sockets and function modules Output circuits CR-U2S CR-U3S Output circuit(s) 11-12/14, 21-22/24,... Number of poles 2 3 Rated voltage 250 V AC Rated current 10 A General data Dimensions see 'Dimensional drawings' Degree of protection terminals IP 20 B (EN 60529) Temperature range operation -40...+70 °C storage -40...+70 °C Connecting capacity rigid 2 x 2 x 0,5 - 2,5 mm2 (2 x 20 - 14 AWG) fine-strand with wire end ferrule 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) Stripping length 7 mm (0.28 in) Tightening torque 0.6 Nm Mounting DIN rail (IEC/EN 60715) Material socket PA 6+GF - V2 contacts CuZn33 contact surface 6 Ni terminals 8 Ni combi screw M3 8.8 steel, 5 Ni Isolation data Insulation voltage > 2 kV Isolation between coil and contacts IEC/EN 61984 Clearance and creepage distance IEC/EN 61984 Standards/Directives Standards IEC/EN 61984 Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU CR-U3E 300 V AC CR-UxSM 2 or 3 250 V -40...+85 °C -40...+85 °C 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) 0.8 Nm -40...+70 °C -40...+70 °C 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG) 0.6 Nm 8 galvanized 3 Ni 10 Ni Steel, 8 Ni -- Technical data - CR-U function modules CR-U 21 Type Version Function Control supply voltage Component data Polarized Material CR-U 41 Type Version Function Control supply voltage Component data Polarized Material CR-U 21 Diode Reverse polarity protection and elimination of the converse current 6-220 V DC Diode 1 A, 1000 V yes (A1+, A2-) Enclosure / Base PA6 + GF V2 CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV Diode and LED Reverse polarity protection and elimination of the converse current. LED to indicate the energization of coil 6-24 V DC 24-60 VDC 110 V DC Diode 1 A, 1000 V LED red green red green red green Resistance 3 k, 0.25 W 15 k, 0.25 W 200 k, 0.25 W yes (A1+, A2-) Enclosure / Base PA6 + GF V2 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 423 -- Pluggable interface relays and optocouplers Technical data - CR-U function modules CR-U 51 Type Version Function Control supply voltage Component data Polarized Material CR-U 61 Type Version Function Control supply voltage Component data Polarized Material CR-U 71, 81 Type Version Function Control supply voltage Component data Polarized Material CR-U 91 Type Version Function Control supply voltage Component data Polarized Material Standards / Directives Standards Low Voltage Directive RoHS Directive CR-U 51B RC element Arc elimination 6-24 V AC/DC Capacitor 0.1 µF, 63 V DC Resistance 10 , 0.25 W no Enclosure / Base PA6 + GF V2 CR-U 51D 24-60 V AC/DC 0.1 µF, 100 V DC 47 , 0.25 W CR-U 51C 110-230 V AC/DC 0.082 µF, 400 V DC 100 , 0.25 W CR-U 61 CR-U 61V CR-U 61E CR-U 61EV CR-U 61C CR-U 61CV CR-U 61D CR-U61DV Diode and LED Varistor and LED Reverse polarity protection and elimination of the converse current. LED to indicate the energization of coil. Overvoltage protection, LED to indicate the energized of coil 6-24 V AC/DC 24-60 V AC/DC 6-24 V AC/DC 24-60 V AC/DC Diode 1 A, 1000 V LED red green red green red green red green Resistance 3 k, 0.25 W 15 k, 0.25 W 3 k, 0.25 W 15 k, 0.25 W AC: no, DC: yes (A1+, A2-) Enclosure / Base PA6 + GF V2 CR-U 71 Varistor Overvoltage protection 24 V AC Varistor 25 V AC no Enclosure / Base PA6 + GF V2 CR-U 71A 115 V AC 115 V AC CR-U 81 230 V AC 275 V AC CR-U 91 CR-U 91V Diode and LED Reverse polarity protection and elimination of the converse current. LED to indicate the energization of coil. 110-230 V AC / 110 V DC Diode 1 A, 1000 V LED red green Resistance 120 k, 0.25 W AC: no, DC: yes (A1+, A2-) Enclosure / Base PA6 + GF V2 CR-U 91C CR-U 91CV Varistor and LED Overvoltage protection, LED to indicate the energized of coil red green IEC/EN 61984 2014/35/EU 2011/65/EU 424 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical diagrams -- Connection diagrams 2CDC 292 015 F0005 2CDC 292 014 F0005 2CDC 292 013 F0005 CR-P/M 22 CR-P/M 42, CR-P/M 42B, CR-P/M 42C, CR-P/M 42V, CR-P/M 42BV, CR-P/M 42CV CR-P/M 52B, CR-P/M 52C CR-P/M 52D, 2CDC 292 018 F0005 2CDC 292 017 F0005 2CDC 292 016 F0005 CR-P/M 62, CR-P/M 62E, CR-P/M 92, CR-P/M 62V, CR-P/M 62EV, CR-P/M 92V CR-P/M 62C, CR-P/M 62D, CR-P/M 92C, CR-P/M 62CV, CR-P/M 62DV, CR-P/M 92CV CR-P/M 72, CR-P/M 82 CR-P/M 72A, 2CDC 292 014 F0005 2CDC 292 013 F0005 CR-U 21 CR-U 41, CR-U 41B, CR-U 41C, CR-U 41V, CR-U 41BV, CR-U 41CV CR-U 51B, CR-U 51C CR-U 51D 2CDC 292 015 F0005 2CDC 292 018 F0005 2CDC 292 017 F0005 2CDC 292 016 F0005 CR-U 61, CR-U 61E, CR-U 91, CR-U 61V, CR-U 61EV, CR-U 91V CR-U 61C, CR-U 61CV, CR-U 61D, CR-U 61DV, CR-U 91C, CR-U 91CV CR-U 71, CR-U 71A , CR-U 81 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 425 -- Pluggable interface relays and optocouplers Technical diagrams -- Connection diagrams 2CDC 292 024 F0004 2CDC 292 011 F0004 2CDC 292 016 F0004 2CDC 292 001 F0004 CR-P with 1 c/o contact CR-M with 2 c/o contacts CR-M with 3 c/o contacts CR-U with 2 c/o contacts 2CDC 292 030 F0004 2CDC 292 001 F0014 2CDC 292 020 F0004 2CDC 292 008 F0004 CR-P with 2 c/o contacts A1 + A2 - CR-S optocoupler with Transistor A1 + A2 - CR-S optocoupler with MOSFET A1 + A2 - CR-S optocoupler with Triac CR-M with 4 c/o contacts CR-S + 11(13+) - 14 2CDC 292 001 F0016 + 11(13+) - 14 2CDC 292 002 F0016 2CDC 292 001 F0016 V AC 11(13+) V AC 14 CR-U with 3 c/o contacts 426 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical diagrams -- CR-P: Operating range of coils U/Us U/Us 2CDC 292 038 F0204 2CDC 292 037 F0204 Ambient temperature [°C] Operating range of DC coil Ambient temperature [°C] Operating range of AC coil A unloaded contacts, coil temperature = ambient temperature B continued with Ith (16 A at CR-P ... 1 and 8 A at CR-P ... 2) loaded contacts coil heated with 1,1 x Us 1 at unloaded contacts 2 at 50 % rated load 3 at rated load -- Electrical connection 22 12 21 11 24 14 21 11 22 2412 14 21 11 24 14 22 12 21 11 22 2412 14 A2 A1 A2 A1 CR-PLS A1-A2 11-12/14, 21-22/24 Supply voltage Relay outputs Relay outputs A2 A1 A2 A1 CR-PLSx, CR-PLC 21 11 24 14 21 11 22 2412 14 A2 A1 A2 A1 22 12 CR-PSS 2CDC 292 063 F0004 2CDC 292 083 F0004 2CDC 292 009 F0007 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 427 -- Pluggable interface relays and optocouplers Technical diagrams -- Mounting and removal of sockets 2CDC 292 061 F0004 2CDC 292 062 F0004 2CDC 292 075 F0004 2CDC 292 074 F0004 2CDC 292 073 F0004 2CDC 292 009 F0004 2CDC 292 008 F0004 Mounting -- Electrical connection 41 11 44 14 42 12 41 11 42 44 12 14 A2 A1 A2 A2 A1 CR-M2LS 41 11 44 14 42 12 41 11 42 44 12 14 A2 A1 A2 A1 CR-M2LC Removal 31 21 11 34 24 14 32 22 12 31 21 11 32 34 22 24 12 14 A2 A1 A2 A2 A1 CR-M3LS 41 31 21 11 44 34 24 14 42 32 22 12 41 31 21 11 42 4432 34 22 2412 14 A2 A1 A2 A1 CR-M4LC 41 31 21 11 44 34 24 14 42 32 22 12 41 31 21 11 42 4432 34 22 2412 14 A2 A1 A2 A2 A1 CR-M4LS 428 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical diagrams -- Electrical connection 44 14 42 12 41 11 42 44 12 14 34 24 14 32 22 12 31 21 11 32 34 22 24 12 14 44 34 24 14 42 32 22 12 41 31 21 11 42 4432 34 22 2412 14 A2 A1 A2 A1 41 11 CR-M2SS, CR-M2SF A1-A2 11-12/14, 41-42/44 Supply voltage Relay outputs Relay outputs 2CDC 292 070 F0004 2CDC 292 069 F0004 2CDC 292 068 F0004 A2 A1 A2 A1 31 21 11 CR-M3SS A1-A2 11-12/14, 21-22/24, 31-32/34 Supply voltage Relay outputs Relay outputs Relay outputs A2 A1 A2 A1 41 31 21 11 CR-M4SS, CR-M4SF A1-A2 11-12/14, 21-22/24 31-32/34 41-42/44 Supply voltage Relay outputs Relay outputs Relay outputs Relay outputs ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 429 -- Pluggable interface relays and optocouplers Technical diagrams -- Technical diagrams CR-S interface relays Operations (*1000 ops) DC current (A) 10 5 2 100 50 1 0.5 10 5 0.2 2CDC 292 012 F0214 0.1 10 20 50 100 200 DC voltage (V) Max. DC load breaking capacity 012 34 5 6 78 Contact current (A) Endurance curve -- Load limit curves CR-P, CR-M and CR-U - Electrical lifetime at resistive AC load 2CDC 292 013 F0214 22CCDDC2C922090290F00290F40204 Switching cycles 22CCDDC2C922902030F00230F40204 Switching cycles Switching cycles 22CCDDC2C92209227F002270F40204 Switching power [kVA] CR-P with 1 c/o contact Switching power [kVA] CR-P with 2 c/o contacts Switching power [kVA] CR-U with 2 and 3 c/o contacts 22CCDDC2C92209128F001280F40204 Switching cycles 22CCDDC2C92209123F001230F40204 Switching cycles Switching cycles 22CCDDC2C92290220F02220F40204 Switching power [kVA] CR-M with 2 c/o contacts Switching power [kVA] CR-M with 3 c/o contacts Switching power [kVA] CR-M with 4 c/o contacts 22CCDDCC2922902280F20820F40204 430 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical diagrams -- Load limit curves CR-P, CR-M and CR-U - Maximum switching power at resistive DC load 1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms DC current [A] DC current [A] DC current [A] 22CCDDC2C922901200F10200F40204 22CCDDC2C922902050F00520F40204 DC voltage [V] CR-P with 1 c/o contact DC voltage [V] CR-P with 2 c/o contacts DC voltage [V] CR-U with 2 and 3 c/o contacts DC current [A] DC current [A] DC current [A] 1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms 22CCDDC2C92290125F001250F40204 DC voltage [V] DC voltage [V] CR-M with 2 c/o contacts CR-M with 3 c/o contacts -- Reduction factor CR-P, CR-M and CR-U F at inductive AC load 22CCDDCC2922902190F1092F004204 1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms 1 2 DC voltage [V] CR-M with 4 c/o contacts 2CDC292023F0204 Reduction factor 2CCDDC2C922902040F00420F40204 Reduction factor Reduction factor 22CCDDC2C92290290F20290F40204 22CCDDC2C922901240F10240F40204 CR-P Power factor CR-M Power factor CR-U Power factor ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 431 -- Pluggable interface relays and optocouplers Technical diagrams -- Derating curves 120 100 80 60 40 20 -20 0 20 40 60 80 100 120 Stand alone installed optocoupler Side-by-side installed optocouplers Ambient temperature [°C] Derating curve Transistor output CR-S 2CDC 292 005 F0016 Current [A] 4 3 2 1 0 10 20 30 40 50 60 70 80 90 Stand alone installed optocoupler Side-by-side installed optocouplers Ambient temperature [°C] Derating curve MOS-FET output CR-S 2CDC 292 006 F0016 Current [A] 2 1.5 1.0 0.5 -20 0 20 40 60 Stand alone installed optocoupler Side-by-side installed optocouplers 80 100 Ambient temperature [°C] Derating curve Triac output CR-S Current [mA] 2CDC 292 007 F0016 22CCDDC2C922902010F00101F70017 Current (A) 22CCDDCC2922902020F00201F70017 Current (A) 6 5 4 3 1 = Stand alone installed 2 = Side by side installed 2 1 0 -20 0 20 40 60 80 100 Ambient temperature (°C) MOS-FET output CR-P 4 3,5 3 2,5 1 = Stand alone installed 2 = Side by side installed 2 1,5 1 0,5 0 -20 0 20 40 60 80 100 Ambient temperature (°C) Triac output CR-P 15 0.591 2CDC292004F0016 432 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical diagrams -- Dimensional drawings in mm and inches 28 1.102 28 1.102 5 0.197 3.8 0.150 15 0.591 2CDC292052F0013 3.5 0.138 0.5 0.020 0.9 0.035 0.5 0.020 16.38 0.645 3.78 0.149 CR-S relay 1 0.039 5.04 0.198 5 0.197 76.6 3.016 6.2 0.244 12 11 14 3.5 0.138 94.7 3.728 35.4 1.394 2CDC292053F0013 12-24 V A1 A2 73.2 2.882 CR-S socket - spring connection 1 0.039 1.8 0.071 CR-S optocoupler 0.8 0.031 1.3 0.051 70.9 2.791 55.4 2.181 35.8 1.409 12 11 14 44.2 1.74 28 1.102 35.4 1.394 2CDC292054F0013 88.3 3.476 69.4 2.732 52 2.047 CR-S socket - screw connection 16.7 0.657 0.8 0.031 6.7 0.264 2.8 0.110 A1 A2 6.3 0.272 20.6 0.811 40.2 1.583 59.8 2.354 71.1 2.799 2CDC292003F0014 2CDC 292 002 F0014 35.7 1.406 92.7 3.650 CR-S separator 123.2 4.850 16.7 0.657 0.8 0.031 2.8 0.110 6.3 0.248 6.7 0.264 CR-SJB20 - blue, CR-SJB20 - red, CR-SJB20 - black jumper bar ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 433 -- Pluggable interface relays and optocouplers Technical diagrams -- Dimensional drawings in mm and inches 12.7 0.5 7.5 0.296 29 1.412 29 1.412 5 0.197 15 0.591 5 0.197 15 0.591 15.7 0.618 2.5 0.098 2.5 0.098 12.7 0.5 7.5 0.296 2CDC292003F0017 2CDC292002F0004 15.7 0.618 3.9 0.154 3.9 0.154 2CDC292033F0004 CR-P relay Marker 15.8 0.622 7.5 0.295 22 NC 12 21 COM 11 24 NO 14 62 2.441 51.2 2.016 29 1.142 Relay 10 0.394 20 0.787 76 2.992 A2 COIL A1 CR-PLS - screw connection Marker 21 COM 11 24 NO 14 42.8 1.685 10 0.394 20 0.787 76 2.992 A2 COIL A1 22 NC 12 24 0.945 15.8 0.622 CR-PSS - screw connection 12.5 0.492 Holder Pluggable function module Holder Relay Pluggable function module 2CDC292007F0211 23.5 0.925 8 0.315 CR- P/Mxx function module 2CDC292006F0211 CR-P optocoupler Marker 21 COM 11 24 NO 14 22 NC 12 62 2.441 61 2.402 42.5 1.673 Relay 78.5 3.091 3.2 0.126 20.32 0.8 5.08 5.08 0.2 0.2 29.4 1.158 A2 COIL A1 7.62 0.3 15.5 0.610 24 0.945 50 1.969 Holder Pluggable function module CR-PLSx - screw connection 7.62 0.3 21 11 24 14 22 12 43.5 1.713 33.8 1.331 24.4 0.961 97.5 3.939 5.08 0.2 20.32 0.8 5.08 0.2 25.9 1.019 2CDC292010F0011 A2 A1 16.3 0.642 34.4 1.354 CR-PLC - spring connection 9x15 (=139.5) 9x0.591 (=5.492) 15.5±0.2 0.610±0.008 2±0.2 0.079±0.008 6±0.2 0.236±0.008 141.5+1 5.571+0.039 CR-PJ jumper bar 10 0.394 R1 10 0.394 1.5 0.059 2CDC292012F0011 434 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Pluggable interface relays and optocouplers Technical diagrams -- Dimensional drawings in mm and inches 6.2 6.3 6.3 4.1 27.5 1.083 35.6 1.402 6.2 6.3 6.3 4.1 27.5 1.083 35.6 1.402 6.2 6.3 6.3 4.1 27.5 1.083 35.6 1.402 2CDC292003F0015 2CDC292002F0015 2CDC292001F0015 2CDC292005F0011 6.5 6.6 0.259 21.2 0.835 2.2x0.5 0.086x0.019 CR-M relay with 2 c/o contacts 6.5 6.6 0.259 21.2 0.835 2.2x0.5 0.086x0.019 CR-M relay with 3 c/o contacts 6.5 4.4 4.4 4.4 21.2 0.835 2.2x0.5 0.086x0.019 CR-M relay with 4 c/o contacts 27.2 1.071 Marker 27.2 1.071 12 11 COM 10 9 41 31 21 11 8 7 NO 6 5 44 34 24 14 4 3 NC 2 1 42 32 22 12 9 8 COM 7 31 21 11 6 5 NO 4 34 24 14 3 2 1 32 22 12 27.2 1.071 12 11 COM 10 9 41 31 21 11 8 7 NO 6 5 44 34 24 14 4 3 NC 2 1 42 32 22 12 60.8 2.394 42.6 1.677 24 0.945 75 2.953 35.4 1.394 A2 A2 A1 14 14 COIL 13 CR-M2LS A2 A2 A1 14 14 COIL 13 CR-M3LS A2 A2 A1 14 14 COIL 13 CR-M4LS 29.1 1.456 CR-M2LS - CR-M3LS - CR-M4LS - screw connection Relay Holder Pluggable function module 2CDC 292 003 F0211 66.7 2.626 35.4 1.394 30.3 1.923 8 7 NO 6 5 44 34 24 14 4 3 NC 2 1 42 32 22 12 29 1.413 max 19 0.748 14 A2 41 31 A1 13 21 11 12 11 COM 10 9 CR-MxSF - screw connection 42.5 1.673 10 0.394 33.2 1.307 31 1.221 24 0.945 R1 12 11 COM 10 9 12.4 0.488 12.4 0.488 41 31 21 11 8 7 NO 6 5 44 34 24 14 4 3 NC 2 1 42 32 22 12 1 5 0.591 95 3.740 5.5 0.217 14 A2 COIL 13 A1 27 1.063 26 1.024 79.5 3.129 CR-M2LC , CR-M4LC - spring connection 9 x 27.2 (=244.8) 9 x 1.071 (=9.638) 246.8 9.717 6±0.2 0.236±0.0079 9.5 0.374 1 0.0394 Marker 27.2 1.071 27.2 1.071 27.2 1.071 8 7 NO 6 5 6 NO 5 4 8 NO 5 44 34 24 14 34 24 14 44 14 4 3 NC 2 1 3 NC 2 1 4 NC 1 42 32 22 12 32 22 12 42 12 42.6 1.677 24 0.945 75.2 2.961 35.4 1.395 A2 COIL COIL A1 14 41 31 21 11 12 11 COM 10 9 A2 COIL 14 31 9 COM COIL A1 13 21 11 8 7 A2 COIL COIL A1 14 13 41 11 12 COM 9 CR-M2SS - CR-M3SS - CR-M4SS - screw connection 1.0709±0.0079 27.2 ±0.2 Relay Holder 0.079±0.0079 2±0.2 2CDC292004F0211 Pluggable function module CR-MJ jumper bar 2CDC292011F0011 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 435 -- Pluggable interface relays and optocouplers Technical diagrams -- Dimensional drawings in mm and inches 2CDC 292 025 F0004 35 1.378 2CDC 292 026 F0004 35 1.378 70 2.756 2CDC292081F0004 35 1.378 13 0.512 CR-U relay with 2 c/o contacts 54.4 2.142 37.3 1.466 24 22 12 14 6 54 3 38.1 1.5 34 32 24 22 14 12 98 7 5 3 4 12 - M3 75.3 2.965 9 - M3 78 1 2 A2 A2 21 11 A1 29.8 1.173 CR-U2S CR-U2S - CR-U3S - screw connection 10 11 6 1 2 A2 A2 31 21 11 A1 29.8 1.173 CR-U3S 75.3 2.965 35.4 1.394 35 1.378 13 0.512 CR-U relay with 3 c/o contacts 54.4 2.142 38 1.496 34 32 24 22 14 12 9 87 5 3 4 Ø4.2 0.165 37.5 1.476 Ø3.2 0.126 0.52.261 32.5 1.279 4 0.157 2CDC292008F0011 10 2 11 6 1 A2 A1 31 11 21 30 1.181 CR-U3E - screw connection 26 1.024 38.1 1.5 27.8 1.094 38.1 1.5 27.8 1.094 26 1.024 8.5 0.335 23.2 0.913 2CDC 292 020 F0005 8 0.315 61.8 2.433 61.8 2.433 35.4 1.394 2CDC292009F0011 8 - M3 CR-U2SM 11 - M3 CR-U3SM CR-U2SM - CR-U3SM - screw connection 4 0.158 34.0 1.339 CR-Uxx function module 436 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 437 -- Boxed interface relays and optocouplers R600 range Table of contents 438 Overview 440 Boxed interface relays R600 range 440 Selection table 442 Ordering details 444 Technical data 448 Technical diagrams 450 Boxed optocouplers R600 range 450 Selection table 451 Ordering details 453 Technical data 456 Technical diagrams 438 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed interface relays and optocouplers R600 range Overview ABB's R600 range may be used in applications where electrical isolation, amplification and signal matching are required. The slim, compact design, incorporated with the variety of terminal connections available allow for the optimization of space within a control panel. This broad portfolio allows for the flexibility of choice and includes both electromagnetic relays and optocouplers. Continuous operation The ABB boxed interface relays portfolio incorporates a large assortment of non-pluggable relays. It includes both electro-mechanical relays and optocouplers. The R600 Optocouplers allow for continuous operation without any mechanical wear-and -tear. Space saving The 6 mm slim housing of the R600 boxed interface relays provides the possibility of space saving within control cabinets . The 75 mm depth of these relays allows for the use in compact cabinets. The ABB boxed interface relays are approved for a large variety of applications and adhere to highest Global availability levels of global approvals (UL, CSA, VDE, CCC). ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 439 -- Boxed interface relays and optocouplers R600 range Overview Complete product line 1 n/o, 1 n/c, 1 c/o, 2 c/o output configuration. Standard contact material for switching high current signals as well as gold-plated contacts for reliable switching of low current signals. 2 DPDT Marine certification The R600 range offers the LR approval, which allows usage of the boxed interface relays and optocouplers in many applications around the marine segment. The performance of the R600 range has been proven by successfully passing tests required for operating under harsh conditions. Safe operation High resistance to vibration and shock thanks to the relay soldered inside of the housing. Wrong relay replacement or relay lose not possible . Devices with immunity to leakage currents. Transistor MOS-FET Triac Longevity Optocoupler with transistor, MOS-FET and Triac output ensure a longer lifetime, higher reliability and quiet operation. Easy to mount The R600 interface relays and optocouplers are easy to mount by snapping onto a DIN-rail according to IEC/EN 60715. Time saving wiring thanks to a jumper bar. JJ J J J JJ JJ J J J J JJ JJ JJ JJJ J JJ JJ J J JJJ J J 11 1111 111122111111 1111111 JJ JJ J JJ J J J JJ J JJJ JJJJJJJJ J Input voltage 5 V DC 12 V DC 24 V DC 48-60 V DC 115 V DC 230 V DC 60-230 V DC 24 V AC 48-60 V AC 115 V AC 230 V AC 60-230 V AC Output rating 10 mA - 6 A 3 mA - 6 A 1 mA - 8 A Output contacts c/o n/o n/c Gold plated contacts Terminal type Screw Spring JJJ JJJJ JJJJJJJJJJJJJJJJ JJ JJJJJJJJJJJJ JJ Type RB121P-5VDC RB121PG-5VDC RBR121P-5VDC RB121-12VDC RB121P-12VDC RB121G-12VDC RBR121P-12VDC RB101R-24VUC RBR101R-24VUC RB111-24VUC RB111R-24VUC RBR111R-24VUC RBR111-24VUC RB121-24VUC RB121G-24VUC RBR121-24VUC RBR121G-24VUC RB122G-24VUC RBR122G-24VUC RB121-24VDC RBR121-24VDC RB121G-24VDC RBR121G-24VDC RB121-48-60VUC RB121G-48-60VUC Order number 1SNA645034R2300 1SNA645036R2500 1SNA645534R2500 1SNA645073R0000 1SNA645035R2400 1SNA645075R0000 1SNA645535R2600 1SNA645019R0400 1SNA645519R0600 1SNA645014R2700 1SNA645018R0300 1SNA645518R0500 1SNA645514R2100 1SNA645001R0300 1SNA645005R0700 1SNA645501R0500 1SNA645505R0100 1SNA645012R2500 1SNA645512R2700 1SNA645071R0000 1SNA645571R0000 1SNA645072R0000 1SNA645572R0000 1SNA645002R0400 1SNA645006R0000 -- Boxed interface relays R600 range Selection table ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 440 JJJ J J JJ J JJ J JJ J JJJJJ J JJJ J JJ J JJJ JJJ J 11 1111112211 11221111122 JJ JJ JJ J J J J J JJ JJJ JJ J J JJ J JJJJ JJJJJJJJ JJJJJJJJJ JJ Input voltage 5 V DC 12 V DC 24 V DC 48-60 V DC 115 V DC 230 V DC 60-230 V DC 24 V AC 48-60 V AC 115 V AC 230 V AC 60-230 V AC Output rating 10 mA - 6 A 3 mA - 6 A 1 mA - 8 A Output contacts c/o n/o n/c Gold plated contacts Terminal type Screw Spring JJJJ JJJJJJJJ JJJJJJJJJ JJ Type RBR121-48-60VUC RBR121G-48-60VUC RB122G-48-60VUC RBR122G-48-60VUC RB121-115VUC RB121G-115VUC RB121R-115VUC RBR121-115VUC RBR121G-115VUC RB122G-115VUC RBR122G-115VUC RB111-115VUC RB111-230VUC RB121-230VUC RB121G-230VUC RB121R-230VUC RBR121-230VUC RBR121G-230VUC RBR121R-230VUC RB122G-230VUC RBR122G-230VUC RB121-60-230VUC RBR121-60-230VUC Order number 1SNA645502R0600 1SNA645506R0200 1SNA645040R1500 1SNA645540R1700 1SNA645003R0500 1SNA645007R0100 1SNA645046R0700 1SNA645503R0700 1SNA645507R0300 1SNA645041R0200 1SNA645541R0400 1SNA645016R2100 1SNA645017R2200 1SNA645004R0400 1SNA645008R1200 1SNA645011R2400 1SNA645504R0000 1SNA645508R1400 1SNA645511R2600 1SNA645013R2600 1SNA645513R2000 1SNA645020R0100 1SNA645520R0300 -- Boxed interface relays R600 range Selection table 441 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 442 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed interface relays R600 range Ordering details R600 - 6 mm 2CDC 291 024 S0013 The R600 range comprises of boxed interface relays and optocouplers. In this range, the relay is soldered into device housing, fulfilling the highest vibration requirements. This compact range of relays are 6 mm wide and provide the possibility of switching AC and DC circuits with the same relay. All the sockets in this range are equipped with an indicator LED and available with screw or spring terminals. -- Ordering details - 1 n/c contact: 250 V, 10 mA - 6 A, width 12 mm Rated control supply voltage Connection type Particularities Type 24 V AC/DC screw spring RC circuit parallel to output contact RB101R-24VUC RBR101R-24VUC Order code Pkg qty 1SNA645019R0400 5 1SNA645519R0600 Weight (1 pc.) kg (lb) 0.04 (0.088) -- Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A, width 6 mm Rated control supply voltage Connection type Particularities Type 24 V AC/DC 115 V AC/DC 230 V AC/DC 24 V AC/DC screw screw screw spring RB111-24VUC RB111-115VUC RB111-230VUC RBR111-24VUC Order code Pkg qty 1SNA645014R2700 10 1SNA645016R2100 1SNA645017R2200 1SNA645514R2100 Weight (1 pc.) kg (lb) 0.02 (0.044) -- Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A, width 12 mm Rated control supply voltage Connection type Particularities Type 24 V AC/DC screw spring RC circuit parallel to output contact RB111R-24VUC RBR111R-24VUC Order code Pkg qty 1SNA645018R0300 5 1SNA645518R0500 Weight (1 pc.) kg (lb) 0.04 (0.088) -- Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A, width 6 mm Rated control supply voltage Connection type Particularities Type Order code Pkg qty 5 V DC 12 V DC 12 V DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC 5 V DC 12 V DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC screw screw screw screw screw screw screw screw spring spring spring spring spring spring spring A1-A2 polarized A1-A2 polarized A1-A2 polarized A1-A2 polarized RB121P-5VDC RB121P-12VDC RB121-12VDC RB121-24VDC RB121-24VUC RB121-48-60VUC RB121-115VUC RB121-230VUC RBR121P-5VDC RBR121P-12VDC RBR121-24VDC RBR121-24VUC RBR121-48-60VUC RBR121-115VUC RBR121-230VUC 1SNA645034R2300 10 1SNA645035R2400 1SNA645073R0000 1SNA645071R0000 1SNA645001R0300 1SNA645002R0400 1SNA645003R0500 1SNA645004R0400 1SNA645534R2500 1SNA645535R2600 1SNA645571R0000 1SNA645501R0500 1SNA645502R0600 1SNA645503R0700 1SNA645504R0000 Weight (1 pc.) kg (lb) 0.02 (0.044) ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 443 -- Boxed interface relays R600 range Ordering details R600 - 12 mm 2CDC 291 013 S0013 -- Ordering details - 1 c/o (SPDT) contact: 250 V, 3 mA - 6 A, gold-plated contacts, width 6 mm Rated control supply voltage Connection type Particularities Type Order code Pkg qty 5 V DC 12 V DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC screw screw screw screw screw screw screw spring spring spring spring spring A1-A2 polarized RB121PG-5VDC 1SNA645036R2500 10 RB121G-12VDC 1SNA645075R0000 RB121G-24VDC 1SNA645072R0000 RB121G-24VUC 1SNA645005R0700 RB121G-48-60VUC 1SNA645006R0000 RB121G-115VUC 1SNA645007R0100 RB121G-230VUC 1SNA645008R1200 RBR121G-24VDC 1SNA645572R0000 RBR121G-24VUC 1SNA645505R0100 RBR121G-48-60VUC 1SNA645506R0200 RBR121G-115VUC 1SNA645507R0300 RBR121G-230VUC 1SNA645508R1400 Weight (1 pc.) kg (lb) 0.02 (0.044) -- Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A, width 12 mm Rated control supply voltage Connection type Particularities Type Order code Pkg qty 60-230 V AC/DC 115 V AC/DC 230 V AC/DC 60-230 V AC/DC 230 V AC/DC screw screw screw spring spring Leakage current protection, RC circuit parallel to input Leakage current protection, RC circuit parallel to input RB121-60-230VUC RB121R-115VUC RB121R-230VUC 1SNA645020R0100 5 1SNA645046R0700 1SNA645011R2400 RBR121-60-230VUC 1SNA645520R0300 RBR121R-230VUC 1SNA645511R2600 Weight (1 pc.) kg (lb) 0.04 (0.088) -- Ordering details - 2 c/o (SPDT) contacts: 250 V, 1 mA - 8 A, gold-plated contacts, width 12 mm Rated control supply voltage 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC Connection type screw screw screw screw spring spring spring spring Type Order code Pkg qty RB122G-24VUC RB122G-48-60VUC RB122G-115VUC RB122G-230VUC RBR122G-24VUC RBR122G-48-60VUC RBR122G-115VUC RBR122G-230VUC 1SNA645012R2500 5 1SNA645040R1500 1SNA645041R0200 1SNA645013R2600 1SNA645512R2700 1SNA645540R1700 1SNA645541R0400 1SNA645513R2000 Weight (1 pc.) kg (lb) 0.04 (0.088) -- Ordering details - Accessories Description Jumper bar, 10 poles * (replacement of BJ612-10 - 1SNA290488R0100) Jumper bar, 20 poles * (replacement of BJ612-20 - 1SNA206754R0000) Separator end section Type RB-JB10 RB-JB20 SC612 Order code Pkg qty 1SVR406570R0000 10 1SVR406580R0000 1SNA290474R0200 * - Before the first and after the last jumpered R600 relay, a separator end section shall be used. - The sum of the current for jumpered devices shall not exceed 6 A on 6 mm devices and 8 A on 12 mm devices. Weight (1 pc.) kg (lb) 0.05 (0.11) 0.10 (0.22) 0.05 (0.11) 444 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed interface relays R600 range Technical data RB(R)101R- RB(R)111R- 24 V UC 24 V UC Input circuit Rated control supply voltage Us Rated control supply voltage Us tolerance 24 V AC/DC DC -15 %, +20 % AC -/+ 10 % Rated frequency 50/60 Hz Typical power consumption 0.24 W Typical current 10 mA Drop-out voltage at 20 °C 4.5 V Indication of operational states green LED V: control supply voltage applied Output circuit Kind of output 11-12 relay, 1 n/c contact - 13-14 - relay, 1 n/o contact Rated operational voltage Ue Minimum switching voltage 250 V AC 5 V Maximum switching voltage 250 V AC Minimum switching current 60 mA Rated free air thermal current Ith Rated operational current Ie 6 A AC-12 (resistive) 230 V 6 A AC-15 (inductive) 230 V 1.5 A AC-15 (inductive) 120 V 3 A DC-12 (resistive) 24 V 6 A DC-13 (inductive) 24 V 1 A DC-13 (inductive) 110 V 0.2 A DC-13 (inductive) 220 V 0.1 A AC rating (UL 508; NEMA ICS-5) utilization category (pilot duty) B300 DC rating (UL 508; NEMA ICS-5) utilization category (pilot duty) R300 Minimum switching power 300 mW Mechanical lifetime 1 x 107 switching cycles Electrical lifetime at AC-15 1 x 105 switching cycles Max. fuse rating to achieve short-circuit protection 6 A fast Response time 5 ms Release time 8 ms Input circuit Rated control supply voltage Us Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states Output circuit Kind of output Rated operational voltage Ue Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current Ith RB(R)11124 V UC 115 V UC 24 V AC/DC 115 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.24 W 0.46 W 10 mA 4 mA at 20 °C 4.5 V 17 V green LED V: control supply voltage applied 13-14 relay, 1 n/o contact 250 V AC 12 V 250 V AC 10 mA 6 A 230 V UC 230 V AC/DC -15 %, +10 % 0.8 W 3.5 mA 27 V ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 445 -- Boxed interface relays R600 range Technical data RB(R)111- 24 V UC Rated operational current Ie AC-12 (resistive) 230 V 6 A AC-15 (inductive) 230 V 1.5 A AC-15 (inductive) 120 V 3 A DC-12 (resistive) 24 V 6 A DC-13 (inductive) 24 V 1 A DC-13 (inductive) 110 V 0.2 A DC-13 (inductive) 220 V 0.1 A AC rating (UL 508; NEMA ICS-5) utilization category (pilot duty) B300 DC rating (UL 508; NEMA ICS-5) utilization category (pilot duty) R300 Minimum switching power 300 mW Mechanical lifetime 1 x 107 switching cycles Electrical lifetime at AC-15 1 x 105 switching cycles Max. fuse rating to achieve short-circuit protection 6 A fast Response time 5 ms Release time 8 ms 115 V UC 6 ms 15 ms 230 V UC 7 ms 15 ms RB(R)121(P)(G)- 5 V DC 12 V DC 24 V DC 24 V UC Input circuit Rated control supply voltage Us Rated control supply voltage Us tolerance 5 V DC 12 V DC DC -15 %, +20 % AC - 24 V DC 24 V AC/DC -/+ 10 % Rated frequency - 50/60 Hz Typical power consumption 0.2 W 0.2 W 0.24 W Typical current 40 mA 16 mA 10 mA Drop-out voltage at 20 °C 1.2 V 2.2 V 4.5 V Indication of operational states green LED control supply voltage applied Output circuit Kind of output 11-12/14 relay, 1 c/o (SPDT) contact Rated operational voltage Ue Minimum switching voltage 250 V AC 5 V / gold-plated contacts: 5 V Maximum switching voltage 250 V AC Minimum switching current 60 mA / gold-plated contacts: 10 mA Rated free air thermal current Ith 6 A Rated operational AC-12 (resistive) 230 V 6 A current Ie AC-15 (inductive) 230 V 1.5 A AC-15 (inductive) 120 V 3 A DC-12 (resistive) 24 V 6 A DC-13 (inductive) 24 V 1 A DC-13 (inductive) 110 V 0.2 A DC-13 (inductive) 220 V 0.1 A AC rating (UL 508; NEMA ICS-5) utilization category B300 (pilot duty) DC rating (UL 508; NEMA ICS-5) utilization category R300 (pilot duty) Minimum switching power 300 mW / gold-plated contacts: 50 mW Mechanical lifetime 1 x 107 switching cycles Electrical lifetime at AC-15 1 x 105 switching cycles Max. fuse rating to achieve shortcircuit protection 6 A fast Response time 5 ms 5 ms 5 ms Release time 8 ms 8 ms 8 ms 48-60 V UC 48 V AC/DC 0.33 W 7 mA 8 V 5 ms 8 ms 60 V AC/DC 0.54 W 9 mA 8 V 5 ms 8 ms 115 V UC 115 V AC/DC 0.46 W 4 mA 17 V 6 ms 15 ms 230 V UC 230 V AC/DC -15 %, +10 % 0.8 W 3.5 mA 27 V 7 ms 16 ms 446 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed interface relays R600 range Technical data RB(R)121R- 115 V UC Input circuit Rated control supply voltage Us Rated control supply voltage Us tolerance 115 V AC/DC DC -20%, +15% AC -/+ 10 % Rated frequency 50/60 Hz Typical power consumption 2 W Typical current 18 mA Drop-out voltage at 20 °C 17 V Indication of operational states green LED V: control supply voltage applied Output circuit Kind of output 11-12/14 relay, 1 c/o (SPDT) contact Rated operational voltage Ue Minimum switching voltage 250 V AC 5 V Maximum switching voltage 250 V AC Minimum switching current 60 mA Rated free air thermal current Ith 6 A Rated operational AC-12 (resistive) 230 V 6 A current Ie AC-15 (inductive) 230 V 1.5 A AC-15 (inductive) 120 V 3 A DC-12 (resistive) 24 V 6 A DC-13 (inductive) 24 V 1 A DC-13 (inductive) 110 V 0.2 A DC-13 (inductive) 220 V 0.1 A AC rating (UL 508; NEMA ICS-5) utilization category B300 (pilot duty) DC rating (UL 508; NEMA ICS-5) utilization category R300 (pilot duty) Minimum switching power 300 mW Mechanical lifetime 1 x 107 switching cycles Electrical lifetime at AC-15 1 x 105 switching cycles Max. fuse rating to achieve short-circuit protection 6 A fast Response time 6 ms Release time 15 ms 230 V UC 230 V AC/DC -10%, +15% 2.8 W 12 mA 27 V 7 ms 16 ms ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 447 -- Boxed interface relays R600 range Technical data RB(R)122G 24 V UC 48-60 V UC Input circuit Rated control supply voltage Us Rated control supply voltage Us tolerance 24 V AC/DC DC -15 %, +20 % AC -/+ 10 % 48 V AC/DC 60 V AC/DC Rated frequency 50/60 Hz Typical power consumption 0.48 W 0.62 W 0.96 W Typical current 20 mA 13 mA 16 mA Drop-out at 20 °C 5.4 V 8.8 V 8.8 V V Indication of operational states green LED V: control supply voltage applied Output circuit Kind of output 11-12/14 relay, 1st c/o (SPDT) contact 21-22/24 relay, 2nd c/o (SPDT) contact Rated operational voltage Ue Minimum switching voltage 250 V AC 5 V / gold-plated contacts: 5 V Maximum switching voltage 250 V Minimum switching current 60 mA / gold-plated contacts: 10 mA Rated free air thermal current Ith 8 A Rated operational AC-12 (resistive) 230 V 8 A current Ie AC-15 (inductive) 230 V 1.5 A DC-12 (resistive) 24 V 8 A DC-13 (inductive) 24 V 1 A DC-13 (inductive) 110 V 0.2 A DC-13 (inductive) 220 V 0.1 A Minimum switching power 300 mW / gold-plated contacts: 50 mW Mechanical lifetime 2 x 107 switching cycles Electrical lifetime at AC-15 1 x 105 switching cycles Max. fuse rating to achieve short-circuit protection 10 A fast Response time 6 ms 10 ms 10 ms Release time 10 ms 14 ms 14 ms 115 V UC 115 V AC/DC 230 V UC 230 V AC/DC -15 %, +10 % 0.58 W 5 mA 20 V 1.15 W 5 mA 10 V 6 ms 15 ms 6 ms 15 ms -- General technical data - Interface relays RB RBR General data Material of housing UL 94 V0 Mounting DIN rail Degree of protection housing / terminals IP20 NEMA1 Electrical connection Screw terminal Spring-type terminal Connecting capacity fine-strand 0.22-2.5 mm² (24-14 AWG) rigid 0.2-4 mm² (24-12 AWG) 0.2-2.5 mm² (24-14 AWG) Stripping length 9 mm (0.354 in) Tightening torque 0.4-0.6 Nm (3.5-5.3 lb.in) n/a Environmental data Ambient temperature ranges storage -40...+80 °C (-40...+176 °F) operation -20...+70 °C (-4...+158 °F) 1) Isolation data Rated insulation voltage Ui 250 V Rated impulse withstand voltage Uimp input / output 4 kV shock coil / output 4 kV output / output 1 kV Overvoltage category III Pollution degree 2 Standards/Directives Standards IEC/EN 60947-5-1 Low Voltage Directive 2014/35/EC RoHS Directive 2011/65/EC 1) Over 55 °C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting max. operation temperature is 15 °C lower. 448 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed interface relays R600 range Technical diagrams -- Load limit curves DC voltage [V] 300 200 100 resistive load 50 40 30 20 10 0.1 0.2 0.5 1 2 5 10 20 DC current [A] Versions with 1 n/o, 1 n/c or 1 c/o contact -- Dimensional drawings in mm and inches 70 2.76" 2CDC292002F0212 DC voltage [V] 300 200 100 resistive load 50 40 30 20 10 0.1 0.2 0.5 1 2 Versions with 2 c/o contacts 5 10 20 DC current [A] 75 2.95" 2CDC292028F0213 67.5 2.66" 75 2.95" 67.5 2.66" 75 2.95" A2 A1 S1 S2 13 14 A2 A1 S1 S2 12 11 14 2CDC292026F0013 2CDC292025F0013 35 1.38" R600 - screw connection 37.5 1.48" R600 - spring connection ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 449 -- Boxed interface relays R600 range Technical diagrams 2CDC292033F0013 2CDC292038F0013 -- Connection diagrams 12 A1 A2 S1 RB(R)101R - 24VUC S2 11 13 A1 A2 S1 RB(R)111R-24VUC S2 14 12 14 A1 A2 S1 RB(R)121(G)-24VUC S2 11 12 14 22 24 A1 A2 11 21 S1 RB(R)122G-24VUC/48-60VUC 2CDC292043F0013 2CDC292039F0013 2CDC292035F0013 2CDC292030F0013 13 A1 A2 S1 RB(R)111-24VUC S2 14 12 14 A1 A2 S1 S2 11 RB(R)121P(G)-5VDC/12VDC 12 14 A1 A2 S1 S2 11 RB(R)121(G)-48-60VUC/ 115VUC/230VUC/60-230VUC 12 14 22 24 A1 A2 S1 RB(R)122G-115VUC/230VUC 11 21 2CDC292044F0013 2CDC292040F0013 2CDC292036F0013 2CDC292031F0013 13 A1 A2 S1 RB111-115VUC/230VUC S2 14 12 14 A1 A2 S1 RB(R)121-12VDC/24VDC S2 11 12 14 A1 A2 S1 RB(R)121R-115VUC/230VUC S2 11 2CDC292042F0013 450 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed optocouplers R600 range Selection table Input voltage 5-12 V DC 24 V DC 48-60 V DC 115-230 V DC 115 V DC 230 V DC 24 V AC 48-60 V AC 115-230 V AC 115 V AC 230 V AC Output rating 100 mA 1 A 2 A 5 A Output voltage 58 V DC 230 V AC 400 V AC Terminal type Screw Spring Kind of output Transistor MOS-FET Triac Type Order number JJ JJ JJJJJJJJ JJ JJ JJ JJ JJ JJ JJJJJJ J J JJJJ JJ JJJ JJ J JJJJJJJJJJJJJJJJJJJJJJJ JJ J J JJ J J J J J JJJ JJJJJ J JJJ J JJJJJJJJ JJJJJJJJJJJJJJJ JJJJJJ OBIC0100-5-12VDC 1SNA645047R0000 OBRIC0100-5-12VDC 1SNA645547R0200 OBIC0100-24VDC 1SNA645021R2600 OBRIC0100-24VDC 1SNA645521R2000 OBIC0100-48-60VUC 1SNA645049R1200 OBRIC0100-48-60VUC 1SNA645549R1400 OBIC0100-115-230 1SNA645022R2700 OBRIC0100-115-230 1SNA645522R2100 OBOC2000-5-12VDC 1SNA645050R1700 OBROC2000-5-12VDC 1SNA645550R1100 OBOC2000-24VDC 1SNA645051R0400 OBOC2000-24VUC 1SNA645025R2200 OBOC5000-24VDC 1SNA645024R2100 OBROC2000-24VDC 1SNA645551R0600 OBROC2000-24VUC 1SNA645525R2400 OBROC5000-24VDC 1SNA645524R2300 JJ JJ JJ JJ J JJJ OBOC2000-48-60VUC 1SNA645053R0600 OBROC2000-48-60VUC 1SNA645553R0000 OBOC2000-115VUC 1SNA645054R0700 J OBOC5000-115VUC 1SNA645058R1300 JJJ JJJ OBOC2000-230VUC 1SNA645026R2300 JJ OBROC2000-230VUC 1SNA645526R2500 J OBROC5000-230VUC 1SNA645559R1600 JJJJ J J JJ JJ OBOA1000-24VDC 1SNA645027R2400 JJ OBOA2000-24VDC 1SNA645029R0600 JJ OBROA1000-24VDC 1SNA645527R2600 OBROA2000-24VDC 1SNA645529R0000 J J JJ OBOA1000-115VUC 1SNA645062R0700 J J OBOA1000-230VUC 1SNA645028R0500 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 451 -- Boxed optocouplers R600 range Ordering details R600 - 6 mm 2CDC 291 024 S0013 -- Ordering details - Transistor output, 58 V DC, 100 mA, width 6 mm Rated control supply voltage Connection type Type Order code 5 - 12 V DC 24 V DC 48 - 60 V AC/DC 115 - 230 V AC/DC 5 - 12 V DC 24 V DC 48 - 60 V AC/DC 115 - 230 V AC/DC screw screw screw screw spring spring spring spring OBIC0100-5-12VDC OBIC0100-24VDC OBIC0100-48-60VUC OBIC0100-115-230 OBRIC0100-5-12VDC OBRIC0100-24VDC OBRIC0100-48-60VUC OBRIC0100-115-230 1SNA645047R0000 1SNA645021R2600 1SNA645049R1200 1SNA645022R2700 1SNA645547R0200 1SNA645521R2000 1SNA645549R1400 1SNA645522R2100 Pkg Weight qty (1 pc.) kg (lb) 10 0.02 (0.044) 10 0.02 (0.044) -- Ordering details - MOS-FET output, 58 V DC, 2 A, width 6 mm Rated control supply voltage Connection type Type Order code 5 - 12 V DC 24 V DC 24 V AC/DC 48 - 60 V AC/DC 115 V AC/DC 230 V AC/DC 5 - 12 V DC 24 V DC 24 V AC/DC 48 - 60 V AC/DC 230 V AC/DC screw screw screw screw screw screw spring spring spring spring spring OBOC2000-5-12VDC 1SNA645050R1700 OBOC2000-24VDC 1SNA645051R0400 OBOC2000-24VUC 1SNA645025R2200 OBOC2000-48-60VUC 1SNA645053R0600 OBOC2000-115VUC 1SNA645054R0700 OBOC2000-230VUC 1SNA645026R2300 OBROC2000-5-12VDC 1SNA645550R1100 OBROC2000-24VDC 1SNA645551R0600 OBROC2000-24VUC 1SNA645525R2400 OBROC2000-48-60VUC 1SNA645553R0000 OBROC2000-230VUC 1SNA645526R2500 Pkg qty 10 10 Weight (1 pc.) kg (lb) 0.02 (0.044) 0.02 (0.044) -- Ordering details - MOS-FET output, 58 V DC, 5 A, width 6 mm Rated control supply voltage Connection type Type Order code 24 V DC 115 V AC/DC 24 V DC 230 V AC/DC screw screw spring spring OBOC5000-24VDC OBOC5000-115VUC OBROC5000-24VDC OBROC5000-230VUC 1SNA645024R2100 1SNA645058R1300 1SNA645524R2300 1SNA645559R1600 Pkg Weight qty (1 pc.) kg (lb) 10 0.02 (0.044) 10 0.02 (0.044) -- Ordering details - Triac output, 400 V AC, 1 A, width 6 mm Rated control supply voltage Connection type Type 24 V DC 115 V AC/DC 230 V AC/DC 24 V DC screw screw screw spring OBOA1000-24VDC OBOA1000-115VUC OBOA1000-230VUC OBROA1000-24VDC Order code 1SNA645027R2400 1SNA645062R0700 1SNA645028R0500 1SNA645527R2600 Pkg Weight qty (1 pc.) kg (lb) 10 0.03 (0.066) 10 452 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed optocouplers R600 range Ordering details R600 - 12 mm 2CDC 291 013 S0013 -- Ordering details - Triac output, 230 V AC, 2 A, width 12 mm Rated control supply voltage Connection type Type Order code 24 V DC 24 V DC screw spring OBOA2000-24VDC OBROA2000-24VDC 1SNA645029R0600 1SNA645529R0000 Pkg Weight qty (1 pc.) kg (lb) 5 0.03 5 (0.066) -- Ordering details - Accessories Description Type Jumper bar, 10 poles * RB-JB10 (replacement of BJ612-10 - 1SNA290488R0100) Jumper bar, 20 poles * RB-JB20 (replacement of BJ612-20 - 1SNA206754R0000) Separator end section SC612 Order code Pkg Weight qty (1 pc.) kg (lb) 1SVR406570R0000 10 0.05 (0.11) 1SVR406580R0000 0.10 (0.22) 1SNA290474R0200 0.05 (0.11) * - Before the first and after the last jumpered R600 optocoupler, a separator end section shall be used. - The sum of the current for jumpered devices shall not exceed 6 A on 6 mm devices and 8 A on 12 mm devices. ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 453 -- Boxed optocouplers R600 range Technical data Input circuit Input voltage Frequency Input current OB(R)IC0100-... 5-12 V DC 5 V DC 5 mA 12 V DC 9 mA Pull-in voltage 4 V Typ. switch-on time 10 µs Typ. switch-off time 500 µs Operating frequency 1000 Hz Permissible leakage current 0.9 mA Output circuit 11(13+)- 14 Kind of output Transistor Rated operational voltage 4.5-58 V DC Minimum switching current 1 mA Maximum switching current 100 mA Leakage current at max. switching voltage < 50 µA Rated operational current Ie (IEC/EN 60947-5-1) DC-12 (resistive) 58 V 0.1 A Residual voltage typical 1 V maximum 1.3 V Max. fuse rating to achieve short-circuit protection 100 mA fast Isolation data Rated insulation voltage Ui 250 V Rated impulse withstand voltage Uimp 2.5 kV Overvoltage category II Pollution degree 2 24 V DC 24 V DC 4 mA 15 V 1.0 mA 48-60 V UC 115-230 48 V AC/DC 50/60 Hz 4 mA 25 V 5 ms 20 ms 0.9 mA 60 V AC/DC 115 V AC/DC 230 V AC/DC 5 mA 7 mA (AC) 11.5 mA (AC) 16 mA (DC) 25 mA (DC) 60 V AC / 70 V DC 20 Hz 1.6 mA OB(R)OC2000-... 5-12 V DC Input circuit Input voltage 5 V DC 12 V DC Frequency - Input current 5 mA 9 mA Pull-in voltage 4 V Typ. switch-on time 15 µs Typ. switch-off time 250 µs Operating frequency 2000 Hz Permissible leakage current 1 mA Output circuit 11(13+)- 14 Kind of output MOS-FET Rated operational voltage 4.5-58 V DC Minimum switching current 1 mA Maximum switching current 2 A Leakage current at max. switching voltage < 50 µA Rated operational current Ie Residual voltage DC-12 (resistive) 58 V 2 A typical 0.1 V maximum 0.5 V Max. fuse rating to achieve short-circuit protection 2 A ultra-fast Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Overvoltage category 250 V 2.5 kV II Pollution degree 2 24 V DC 24 V UC 48-60 V UC 115 V UC 230 V UC 24 V DC 5.4 mA 12 V 30 µs 400 µs 1000 Hz 0.8 mA 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC 50/60 Hz 6.3 mA 4 mA 5.1 mA 4.2 mA 4 mA 15 V 27 V 50 V 80 V 1 ms 5 ms 500 µs 1 ms 7 ms 20 ms 10 ms 15 ms 60 Hz 20 Hz 50 Hz 35 Hz 0.9 mA 1 mA 0.3 mA 454 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed optocouplers R600 range Technical data OB(R)OC5000-... 24 V DC Input circuit Input voltage 24 V DC Frequency - Input current 5.4 mA Pull-in voltage 12 V Typ. switch-on time 30 µs Typ. switch-off time 400 µs Operating frequency 1000 Hz Permissible leakage current 0.8 mA Output circuit 11(13+)- 14 Kind of output MOS-FET Rated operational voltage 4.5-58 V DC Minimum switching current 1 mA Maximum switching current 5 A Leakage current at max. switching voltage < 50 µA Rated operational current Ie Residual voltage DC-12 (resistive) 58 V 5 A typical 0.1 V maximum 0.5 V Max. fuse rating to achieve short-circuit protection 6 A ultra-fast Isolation data Rated insulation voltage Ui 250 V Rated impulse withstand voltage Uimp 2.5 kV Overvoltage category II Pollution degree 2 115 V UC 115 V AC/DC 50/60 Hz 4.2 mA 50 V 500 µs 10 ms 50 Hz 0.3 mA 230 V UC 230 V AC/DC 4 mA 80 V 1 ms 15 ms 35 Hz 0.3 mA OB(R)OA1000-... 24 V DC Input circuit Input voltage 24 V DC Frequency - Input current 3.6 mA Pull-in voltage 14 V Typ. switch-on time 150 µs Typ. switch-off time 1 ms Operating frequency 500 Hz Permissible leakage current 1 mA Output circuit 11(13+)- 14 Kind of output Triac Rated operational voltage 24-400 V AC Minimum switching current 25 mA Maximum switching current 1 A Leakage current at max. switching voltage < 500 µA Rated operational current Ie AC-12 (resistive) 400 V 1 A AC-12 (resistive) 230 V - Residual voltage typical 1 V maximum 1.6 V Max. fuse rating to achieve short-circuit protection 4 A ultra-fast Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Overvoltage category 400 V 4 kV II Pollution degree 2 115 V UC 115 V AC/DC 50/60 Hz 4.15 mA 60 V 2.2 ms 18 ms 25 Hz 230 V UC 230 V AC/DC 4.6 mA 135 V 2.5 ms 25 ms 20 Hz OB(R)OA2000-... 24 V DC 24 V DC 3.6 mA 14 V 150 µs 1 ms 500 Hz 1 mA Triac 10-230 V AC 25 mA 2 A < 500 µA 2A 1 V 1.6 V 4 A ultra-fast 230 V 4 kV II 2 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 455 -- Boxed optocouplers R600 range Technical data -- General technical data - Optocouplers General data Material of housing Mounting Degree of protection Electrical connection Connecting capacity Stripping length Tightening torque Environmental data Ambient temperature ranges Standards/Directives Standards Low Voltage Directive RoHS Directive OB UL 94 V0 DIN Rail housing / terminals IP20 NEMA1 Screw terminal fine-strand 0.22-2.5 mm² (24-14 AWG) rigid 0.2-4 mm² (24-12 AWG) 9 mm (0.354 in) 0.4-0.6 Nm (3.5-5.3 lb.in) storage -40...+80 °C (-40...+176 °F) operation -20...+70 °C (-4...+158 °F) IEC/EN 60947-5-1 2014/35/EU 2011/65/EU OBR Spring-type terminal 0.2-2.5 mm² (24-14 AWG) n/a 456 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS -- Boxed optocouplers R600 range Technical diagrams -- Dimensional drawings in mm and inches 70 2.76" 75 2.95" 67.5 2.66" 75 2.95" 67.5 2.66" 75 2.95" A2 A1 S1 S2 13 14 A2 A1 S1 S2 12 11 14 2CDC292026F0013 2CDC292025F0013 35 1.38" R600 - screw connection -- Connection diagrams A1 A2 S1 OB(R)OC, OB(R)IC except 5-12 V DC versions 13 (+) 14 (-) S2 2CDC292019F0016 37.5 1.48" R600 - spring connection A1 A2 S1 OB(R)IC0100-5-12 V DC OB(R)OC2000-5-12 V DC 13 (+) 14 (-) S2 2CDC292017F0016 A1 A2 S1 OB(R)OA 13 (+) 14 (-) S2 2CDC292018F0016 ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS 457 458 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type ADP.01 ADP.01 ADP.02 C011-100 C011-110 C011-120 C011-130 C011-140 C011-150 C011-160 C011-170 C011-3-150 C011-70 C011-80 C011-90 CM-AH-3 CM-CT 100/1 CM-CT 100/5 CM-CT 150/1 CM-CT 150/5 CM-CT 200/1 CM-CT 200/5 CM-CT 300/1 CM-CT 300/5 CM-CT 400/1 CM-CT 400/5 CM-CT 50/1 CM-CT 50/5 CM-CT 500/1 CM-CT 500/5 CM-CT 600/1 CM-CT 600/5 CM-CT 75/1 CM-CT 75/5 CM-CT A CM-EFS.2P CM-EFS.2S CM-ENE MAX CM-ENE MAX CM-ENE MAX CM-ENE MIN CM-ENE MIN CM-ENE MIN CM-ENS.11P CM-ENS.11S CM-ENS.13P CM-ENS.13S CM-ENS.21P CM-ENS.21S CM-ENS.23P CM-ENS.23S Order code 1SVR430029R0100 1SVR430029R0100 1SVR440029R0100 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0011 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110033R0008 GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 1SVR450056R7000 1SVR450116R1200 1SVR450116R5200 1SVR450116R1300 1SVR450116R5300 1SVR450116R1400 1SVR450116R5400 1SVR450117R1100 1SVR450117R5100 1SVR450117R1200 1SVR450117R5200 1SVR450116R1000 1SVR450116R5000 1SVR450117R1300 1SVR450117R5300 1SVR450117R1400 1SVR450117R5400 1SVR450116R1100 1SVR450116R5100 1SVR450118R1000 1SVR740750R0400 1SVR730750R0400 1SVR550855R9400 1SVR550850R9400 1SVR550851R9400 1SVR550855R9500 1SVR550850R9500 1SVR550851R9500 1SVR730850R2100 1SVR730850R0100 1SVR740850R2100 1SVR740850R0100 1SVR740850R0200 1SVR730850R0200 1SVR740850R2200 1SVR730850R2200 Page 41 242 242 191 191 191 191 191 191 191 191 191 191 191 191 242 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 89 89 229 229 229 229 229 229 229 229 229 229 229 229 229 229 Type CM-ENS.31P CM-ENS.31S CM-ESS.1P CM-ESS.1P CM-ESS.1P CM-ESS.1S CM-ESS.1S CM-ESS.1S CM-ESS.2P CM-ESS.2P CM-ESS.2P CM-ESS.2S CM-ESS.2S CM-ESS.2S CM-ESS.MP CM-ESS.MS CM-GM-1 CM-HC CM-HCT CM-HE CM-IVN.P CM-IVN.S CM-IWM.10 CM-IWM.11 CM-IWN.1P CM-IWN.1S CM-IWS.1P CM-IWS.1S CM-IWS.2P CM-IWS.2S CM-KH-3 CM-MPN.52P CM-MPN.52S CM-MPN.62P CM-MPN.62S CM-MPN.72P CM-MPN.72S CM-MPS.11P CM-MPS.11S CM-MPS.21P CM-MPS.21S CM-MPS.23P CM-MPS.23S CM-MPS.31P CM-MPS.31S CM-MPS.41P CM-MPS.41S CM-MPS.43P CM-MPS.43S CM-MSE CM-MSE Order code 1SVR740850R0300 1SVR730850R0300 1SVR740830R0300 1SVR740831R0300 1SVR740831R1300 1SVR730830R0300 1SVR730831R0300 1SVR730831R1300 1SVR740830R0400 1SVR740831R0400 1SVR740831R1400 1SVR730830R0400 1SVR730831R0400 1SVR730831R1400 1SVR740830R0500 1SVR730830R0500 1SVR450056R8000 1SVR402902R1000 1SVR402902R2000 1SVR402902R0000 1SVR760669R9400 1SVR750669R9400 1SVR470670R1000 1SVR470670R1100 1SVR760660R0200 1SVR750660R0200 1SVR740660R0100 1SVR730660R0100 1SVR740670R0200 1SVR730670R0200 1SVR450056R6000 1SVR760487R8300 1SVR750487R8300 1SVR760488R8300 1SVR750488R8300 1SVR760489R8300 1SVR750489R8300 1SVR740885R1300 1SVR730885R1300 1SVR740885R3300 1SVR730885R3300 1SVR740885R4300 1SVR730885R4300 1SVR740884R1300 1SVR730884R1300 1SVR740884R3300 1SVR730884R3300 1SVR740884R4300 1SVR730884R4300 1SVR550805R9300 1SVR550800R9300 Page 229 229 89 89 89 89 89 89 89 89 89 89 89 89 89 89 242 242 242 242 161 161 161 161 161 161 161 161 161 161 242 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 190 190 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type CM-MSE CM-MSS.11P CM-MSS.11S CM-MSS.12P CM-MSS.12S CM-MSS.13P CM-MSS.13S CM-MSS.21P CM-MSS.21S CM-MSS.22P CM-MSS.22S CM-MSS.23P CM-MSS.23S CM-MSS.31P CM-MSS.31S CM-MSS.32P CM-MSS.32S CM-MSS.33P CM-MSS.33S CM-MSS.41P CM-MSS.41S CM-MSS.51P CM-MSS.51S CM-PAS.31P CM-PAS.31S CM-PAS.41P CM-PAS.41S CM-PBE CM-PBE CM-PFE CM-PFE.2 CM-PFS.P CM-PFS.S CM-PSS.31P CM-PSS.31S CM-PSS.41P CM-PSS.41S CM-PVE CM-PVE CM-PVS.31P CM-PVS.31S CM-PVS.41P CM-PVS.41S CM-PVS.81P CM-PVS.81S CM-SE-1000 CM-SE-300 CM-SE-600 CM-SFS.21P CM-SFS.21S CM-SFS.22S Order code 1SVR550801R9300 1SVR740720R1400 1SVR730720R1400 1SVR740700R0100 1SVR730700R0100 1SVR740700R2100 1SVR730700R2100 1SVR740722R1400 1SVR730722R1400 1SVR740700R0200 1SVR730700R0200 1SVR740700R2200 1SVR730700R2200 1SVR740712R1400 1SVR730712R1400 1SVR740712R0200 1SVR730712R0200 1SVR740712R2200 1SVR730712R2200 1SVR740712R1200 1SVR730712R1200 1SVR740712R1300 1SVR730712R1300 1SVR740774R1300 1SVR730774R1300 1SVR740774R3300 1SVR730774R3300 1SVR550881R9400 1SVR550882R9500 1SVR550824R9100 1SVR550826R9100 1SVR740824R9300 1SVR730824R9300 1SVR740784R2300 1SVR730784R2300 1SVR740784R3300 1SVR730784R3300 1SVR550870R9400 1SVR550871R9500 1SVR740794R1300 1SVR730794R1300 1SVR740794R3300 1SVR730794R3300 1SVR740794R2300 1SVR730794R2300 1SVR450056R0200 1SVR450056R0000 1SVR450056R0100 1SVR740760R0400 1SVR730760R0400 1SVR730760R0500 Page 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 242 242 242 87 87 87 Type CM-SRS.11P CM-SRS.11P CM-SRS.11P CM-SRS.11S CM-SRS.11S CM-SRS.11S CM-SRS.12S CM-SRS.12S CM-SRS.12S CM-SRS.21P CM-SRS.21P CM-SRS.21P CM-SRS.21S CM-SRS.21S CM-SRS.21S CM-SRS.22S CM-SRS.22S CM-SRS.22S CM-SRS.M1P CM-SRS.M1S CM-SRS.M2S CM-TCS.11P CM-TCS.11S CM-TCS.12P CM-TCS.12S CM-TCS.13P CM-TCS.13S CM-TCS.21P CM-TCS.21S CM-TCS.22P CM-TCS.22S CM-TCS.23P CM-TCS.23S CM-UFD.M22M CM-UFD.M31 CM-UFD.M31M CM-UFD.M33 CM-UFD.M33M CM-UFD.M34M COV.01 COV.02 COV.11 COV.11 COV.12 CP-B 24/10.0 CP-B 24/20.0 CP-B 24/3.0 CP-B EXT.2 CP-C.1 24/10.0 CP-C.1 24/10.0-C CP-C.1 24/10.0-L Order code 1SVR740840R0200 1SVR740841R0200 1SVR740841R1200 1SVR730840R0200 1SVR730841R0200 1SVR730841R1200 1SVR730840R0300 1SVR730841R0300 1SVR730841R1300 1SVR740840R0400 1SVR740841R0400 1SVR740841R1400 1SVR730840R0400 1SVR730841R0400 1SVR730841R1400 1SVR730840R0500 1SVR730841R0500 1SVR730841R1500 1SVR740840R0600 1SVR730840R0600 1SVR730840R0700 1SVR740740R0100 1SVR730740R0100 1SVR740740R0200 1SVR730740R0200 1SVR740740R0300 1SVR730740R0300 1SVR740740R9100 1SVR730740R9100 1SVR740740R9200 1SVR730740R9200 1SVR740740R9300 1SVR730740R9300 1SVR560731R3700 1SVR560730R3401 1SVR560731R3701 1SVR560730R3402 1SVR560731R3702 1SVR560731R3703 1SVR430005R0100 1SVR440005R0100 1SVR730005R0100 1SVR730005R0100 1SVR750005R0100 1SVR427060R1000 1SVR427060R2000 1SVR427060R0300 1SVR427065R0000 1SVR360663R1001 1SVR360663R2001 1SVR361663R1001 459 Page 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 209 209 209 209 209 209 209 209 209 209 209 209 145 145 145 145 145 145 242 242 41 242 242 332 332 332 332 294 294 294 460 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type CP-C.1 24/20.0 CP-C.1 24/20.0-C CP-C.1 24/20.0-L CP-C.1 24/5.0 CP-C.1 24/5.0-C CP-C.1 24/5.0-L CP-C.1-A-RU CP-C.1-A-RU-C CP-C.1-A-RU-L CP-D 12/0.83 CP-D 12/2.1 CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 CP-D RU CP-E 12/10.0 CP-E 12/2.5 CP-E 24/0.75 CP-E 24/1.25 CP-E 24/10.0 CP-E 24/2.5 CP-E 24/20.0 CP-E 24/5.0 CP-E 48/0.62 CP-E 48/1.25 CP-E 48/10.0 CP-E 48/5.0 CP-E 5/3.0 CP-RUD CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0 CP-T 24/5.0 CP-T 48/10.0 CP-T 48/20.0 CP-T 48/5.0 CR-M012AC2L CR-M012AC3L CR-M012AC4L CR-M012DC2 CR-M012DC2L CR-M012DC2LD CR-M012DC3 CR-M012DC3L CR-M012DC3LD CR-M012DC4 CR-M012DC4L CR-M012DC4LD CR-M012DC4LDG CR-M012DC4LDGSS Order code 1SVR360763R1001 1SVR360763R2001 1SVR361763R1001 1SVR360563R1001 1SVR360563R2001 1SVR361563R1001 1SVR360060R1001 1SVR360060R2001 1SVR361060R1001 1SVR427041R1000 1SVR427043R1200 1SVR427041R0000 1SVR427043R0100 1SVR427044R0200 1SVR427045R0400 1SVR427049R0000 1SVR427035R1000 1SVR427032R1000 1SVR427030R0000 1SVR427031R0000 1SVR427035R0000 1SVR427032R0000 1SVR427036R0000 1SVR427034R0000 1SVR427030R2000 1SVR427031R2000 1SVR427035R2000 1SVR427034R2000 1SVR427033R3000 1SVR423418R9000 1SVR427055R0000 1SVR427056R0000 1SVR427057R0000 1SVR427054R0000 1SVR427055R2000 1SVR427056R2000 1SVR427054R2000 1SVR405611R0300 1SVR405612R0300 1SVR405613R0300 1SVR405611R4000 1SVR405611R4100 1SVR405611R4400 1SVR405612R4000 1SVR405612R4100 1SVR405612R4400 1SVR405613R4000 1SVR405613R4100 1SVR405613R4400 1SVR405618R4400 1SVR405618R4410 Page 294 294 294 294 294 294 342 342 342 318 318 318 318 318 318 342 260 260 260 260 260 260 260 260 260 260 260 260 260 342 280 280 280 280 280 280 280 398 398 398 397 398 399 397 398 399 397 398 399 400 401 Type CR-M012DC4LG CR-M024AC2 CR-M024AC2L CR-M024AC3 CR-M024AC3L CR-M024AC4 CR-M024AC4G CR-M024AC4L CR-M024AC4LG CR-M024AC4LS62CV CR-M024DC2 CR-M024DC2L CR-M024DC2LD CR-M024DC3 CR-M024DC3L CR-M024DC3LD CR-M024DC4 CR-M024DC4G CR-M024DC4GLC62CV CR-M024DC4GSS42V CR-M024DC4L CR-M024DC4LC42 CR-M024DC4LD CR-M024DC4LDG CR-M024DC4LDGSS CR-M024DC4LG CR-M024DC4LGLC22 CR-M024DC4LS42V CR-M024DC4SS42V CR-M048AC2 CR-M048AC2L CR-M048AC3 CR-M048AC3L CR-M048AC4 CR-M048AC4L CR-M048AC4LG CR-M048DC2 CR-M048DC2L CR-M048DC2LD CR-M048DC3 CR-M048DC3L CR-M048DC3LD CR-M048DC4 CR-M048DC4L CR-M048DC4LD CR-M048DC4LG CR-M060AC3 CR-M060DC2 CR-M060DC2L CR-M060DC3 CR-M060DC3L Order code 1SVR405618R4100 1SVR405611R0000 1SVR405611R0100 1SVR405612R0000 1SVR405612R0100 1SVR405613R0000 1SVR405618R0000 1SVR405613R0100 1SVR405618R0100 1SVR405613R0010 1SVR405611R1000 1SVR405611R1100 1SVR405611R1400 1SVR405612R1000 1SVR405612R1100 1SVR405612R1400 1SVR405613R1000 1SVR405618R1000 1SVR405618R1010 1SVR405618R1011 1SVR405613R1100 1SVR405613R1012 1SVR405614R1100 1SVR405618R1400 1SVR405618R1410 1SVR405618R1100 1SVR405618R1110 1SVR405613R1011 1SVR405613R1010 1SVR405611R5000 1SVR405611R5100 1SVR405612R5000 1SVR405612R5100 1SVR405613R5000 1SVR405613R5100 1SVR405618R5100 1SVR405611R6000 1SVR405611R6100 1SVR405611R6400 1SVR405612R6000 1SVR405612R6100 1SVR405612R6400 1SVR405613R6000 1SVR405613R6100 1SVR405613R6400 1SVR405618R6100 1SVR405612R5200 1SVR405611R4200 1SVR405611R4300 1SVR405612R4200 1SVR405612R4300 Page 400 397 398 397 398 397 399 398 400 401 397 398 399 397 398 399 397 399 401 401 398 401 399 400 401 400 401 401 401 397 398 397 398 397 398 400 397 398 399 397 398 399 397 398 399 400 397 397 398 397 398 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type CR-M060DC4 CR-M060DC4L CR-M060DC4LG CR-M110AC2 CR-M110AC2L CR-M110AC3 CR-M110AC3L CR-M110AC4 CR-M110AC4G CR-M110AC4L CR-M110AC4LG CR-M110DC2 CR-M110DC2L CR-M110DC2LD CR-M110DC3 CR-M110DC3L CR-M110DC3LD CR-M110DC4 CR-M110DC4L CR-M110DC4LD CR-M110DC4LG CR-M120AC2 CR-M120AC2L CR-M120AC3 CR-M120AC3L CR-M120AC4 CR-M120AC4L CR-M120AC4LG CR-M125DC2 CR-M125DC2L CR-M125DC2LD CR-M125DC3 CR-M125DC3L CR-M125DC3LD CR-M125DC4 CR-M125DC4L CR-M125DC4LD CR-M125DC4LG CR-M220DC2 CR-M220DC2L CR-M220DC2LD CR-M220DC3 CR-M220DC3L CR-M220DC3LD CR-M220DC4 CR-M220DC4L CR-M220DC4LD CR-M220DC4LG CR-M230AC2 CR-M230AC2L CR-M230AC3 Order code 1SVR405613R4200 1SVR405613R4300 1SVR405618R4300 1SVR405611R7000 1SVR405611R7100 1SVR405612R7000 1SVR405612R7100 1SVR405613R7000 1SVR405618R7000 1SVR405613R7100 1SVR405618R7100 1SVR405611R8000 1SVR405611R8100 1SVR405611R8400 1SVR405612R8000 1SVR405612R8100 1SVR405612R8400 1SVR405613R8000 1SVR405613R8100 1SVR405613R8400 1SVR405618R8100 1SVR405611R2000 1SVR405611R2100 1SVR405612R2000 1SVR405612R2100 1SVR405613R2000 1SVR405613R2100 1SVR405618R2100 1SVR405611R8200 1SVR405611R8300 1SVR405611R8500 1SVR405612R8200 1SVR405612R8300 1SVR405612R8500 1SVR405613R8200 1SVR405613R8300 1SVR405613R8500 1SVR405618R8300 1SVR405611R9000 1SVR405611R9100 1SVR405611R9400 1SVR405612R9000 1SVR405612R9100 1SVR405612R9400 1SVR405613R9000 1SVR405613R9100 1SVR405613R9400 1SVR405618R9100 1SVR405611R3000 1SVR405611R3100 1SVR405612R3000 Page 397 398 400 397 398 397 398 397 399 398 400 397 398 399 397 398 399 397 398 399 400 397 398 397 398 397 398 400 397 398 399 397 398 399 397 398 399 400 397 398 399 397 398 399 397 398 399 400 397 398 397 Type CR-M230AC3L CR-M230AC4 CR-M230AC4G CR-M230AC4GSS92CV CR-M230AC4L CR-M230AC4LC92 CR-M230AC4LG CR-M230AC4LGLC CR-M230AC4LGSS CR-M230AC4LS92CV CR-M230AC4SS92CV CR-M2LC CR-M2LS CR-M2SF CR-M2SS CR-M3LS CR-M3SS CR-M4LC CR-M4LS CR-M4SF CR-M4SS CR-MH CR-MH1 CR-MJ CR-MM CR-MP CR-P/M 22 CR-P/M 42 CR-P/M 42 B CR-P/M 42 BV CR-P/M 42 C CR-P/M 42 CV CR-P/M 42 V CR-P/M 52B CR-P/M 52C CR-P/M 52D CR-P/M 62 CR-P/M 62 C CR-P/M 62 CV CR-P/M 62 D CR-P/M 62 DV CR-P/M 62 E CR-P/M 62 EV CR-P/M 62 V CR-P/M 72 CR-P/M 72 A CR-P/M 82 CR-P/M 92 CR-P/M 92 C CR-P/M 92 CV CR-P/M 92 V Order code 1SVR405612R3100 1SVR405613R3000 1SVR405618R3000 1SVR405618R3112 1SVR405613R3100 1SVR405613R3012 1SVR405618R3100 1SVR405618R3110 1SVR405618R3111 1SVR405613R3011 1SVR405613R3110 1SVR405651R1200 1SVR405651R1100 1SVR405651R1300 1SVR405651R1000 1SVR405651R2100 1SVR405651R2000 1SVR405651R3200 1SVR405651R3100 1SVR405651R3300 1SVR405651R3000 1SVR405659R1000 1SVR405659R1100 1SVR405658R6000 1SVR405658R1000 1SVR405658R2000 1SVR405651R0000 1SVR405652R0000 1SVR405652R4000 1SVR405652R4100 1SVR405652R9000 1SVR405652R9100 1SVR405652R1000 1SVR405653R0000 1SVR405653R1000 1SVR405653R4000 1SVR405654R0000 1SVR405655R0000 1SVR405655R1000 1SVR405655R4000 1SVR405655R4100 1SVR405654R4000 1SVR405654R4100 1SVR405654R1000 1SVR405656R0000 1SVR405656R1000 1SVR405656R2000 1SVR405654R0100 1SVR405655R0100 1SVR405655R1100 1SVR405654R1100 461 Page 398 397 399 402 398 402 400 402 402 402 402 403 403 403 403 403 403 403 403 403 403 403 403 403 403 403 404 404 404 404 404 404 404 404 404 404 404 405 405 405 405 404 404 404 405 405 405 404 405 405 404 462 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type CR-P012AC2 CR-P012DC1 CR-P012DC1SS42V CR-P012DC2 CR-P012DC2SS42V CR-P024AC1 CR-P024AC1SS62CV CR-P024AC2 CR-P024AC2G CR-P024AC2SS62CV CR-P024DC1 CR-P024DC1LC42V CR-P024DC1LC62C CR-P024DC1SS42V CR-P024DC2 CR-P024DC2G CR-P024DC2GLC42V CR-P024DC2GLC62C CR-P024DC2GLC62CV CR-P024DC2LC42 CR-P024DC2LS42 CR-P024DC2LS42V CR-P024DC2SS42V CR-P024MOS1 CR-P024TRI1 CR-P048AC1 CR-P048AC2 CR-P048DC1 CR-P048DC2 CR-P110AC1 CR-P110AC2 CR-P110AC2G CR-P110DC1 CR-P110DC1SS42CV CR-P110DC2 CR-P110DC2SS42CV CR-P120AC1 CR-P120AC1SS92CV CR-P120AC2 CR-P120AC2SS92CV CR-P230AC1 CR-P230AC1LC92CV CR-P230AC1LS CR-P230AC1SS92CV CR-P230AC2 CR-P230AC2G CR-P230AC2GLC92 CR-P230AC2GLC92C CR-P230AC2GLC92CV CR-P230AC2LC92 CR-P230AC2LS92CV Order code 1SVR405601R0200 1SVR405600R4000 1SVR405600R4010 1SVR405601R4000 1SVR405601R4010 1SVR405600R0000 1SVR405600R0010 1SVR405601R0000 1SVR405606R0000 1SVR405601R0010 1SVR405600R1000 1SVR405600R1011 1SVR405600R1013 1SVR405600R1010 1SVR405601R1000 1SVR405606R1000 1SVR405606R1010 1SVR405606R1013 1SVR405606R1011 1SVR405601R1012 1SVR405601R1013 1SVR405601R1011 1SVR405601R1010 1SVR405610R4060 1SVR405610R4070 1SVR405600R5000 1SVR405601R5000 1SVR405600R6000 1SVR405601R6000 1SVR405600R7000 1SVR405601R7000 1SVR405606R7000 1SVR405600R8000 1SVR405600R8010 1SVR405601R8000 1SVR405601R8010 1SVR405600R2000 1SVR405600R2010 1SVR405601R2000 1SVR405601R2010 1SVR405600R3000 1SVR405600R3010 1SVR405600R3011 1SVR405600R3110 1SVR405601R3000 1SVR405606R3000 1SVR405606R3013 1SVR405606R3012 1SVR405606R3010 1SVR405601R3012 1SVR405601R3011 Page 393 393 395 393 396 393 395 393 393 396 393 395 395 395 393 393 396 396 396 396 396 396 396 393 393 393 393 393 393 393 393 393 393 395 393 396 393 395 393 396 393 395 395 395 393 393 396 396 396 396 396 Type CR-P230AC2SS92CV CR-PH CR-PH1 CR-PJ CR-PLC CR-PLS CR-PLSX CR-PM CR-PSS CR-S005VDC1R CR-S005VDC1RG CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012VDC1R CR-S012VDC1RG CR-S024VADC1CRGS CR-S024VADC1CRGZ CR-S024VADC1CRS CR-S024VADC1CRZ CR-S024VDC1MOS CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1TRA CR-S024VDC1TRI CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S110VADC1CRGS CR-S110VADC1CRGZ CR-S110VADC1CRS CR-S110VADC1CRZ CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S230VADC1CRGS CR-S230VADC1CRGZ CR-S230VADC1CRS CR-S230VADC1CRZ CR-SJB20-BLACK CR-SJB20-BLUE CR-SJB20-RED CR-SSEP CR-U 21 CR-U 41 CR-U 41B Order code 1SVR405601R3110 1SVR405659R0000 1SVR405659R0100 1SVR405658R5000 1SVR405650R0200 1SVR405650R0000 1SVR405650R0100 1SVR405658R0000 1SVR405650R1000 1SVR405501R1010 1SVR405501R1020 1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405501R2010 1SVR405501R2020 1SVR405541R3120 1SVR405541R3220 1SVR405541R3110 1SVR405541R3210 1SVR405510R3060 1SVR405501R3010 1SVR405501R3020 1SVR405510R3050 1SVR405510R3070 1SVR405521R5100 1SVR405521R5200 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405521R6100 1SVR405521R6200 1SVR405541R6120 1SVR405541R6220 1SVR405541R6110 1SVR405541R6210 1SVR405521R7100 1SVR405521R7200 1SVR405541R7120 1SVR405541R7220 1SVR405541R7110 1SVR405541R7210 1SVR405598R0900 1SVR405598R0700 1SVR405598R0800 1SVR405599R0000 1SVR405661R0000 1SVR405662R0000 1SVR405662R4000 Page 396 394 394 394 394 394 394 394 394 389 389 390 390 390 390 389 389 389 389 389 389 389 389 389 389 389 390 390 389 389 389 389 390 390 389 389 389 389 390 390 389 389 389 389 390 390 390 390 408 408 408 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type CR-U 41BV CR-U 41C CR-U 41CV CR-U 41V CR-U 51B CR-U 51C CR-U 51D CR-U 61 CR-U 61C CR-U 61CV CR-U 61D CR-U 61DV CR-U 61E CR-U 61EV CR-U 61V CR-U 71 CR-U 71A CR-U 81 CR-U 91 CR-U 91C CR-U 91CV CR-U 91V CR-U T CR-U012AC2L CR-U012AC3L CR-U012DC2 CR-U012DC2L CR-U012DC2LD CR-U012DC3 CR-U012DC3L CR-U012DC3LD CR-U024AC2 CR-U024AC2L CR-U024AC3 CR-U024AC3L CR-U024DC2 CR-U024DC2L CR-U024DC2LD CR-U024DC3 CR-U024DC3L CR-U024DC3LD CR-U048AC2 CR-U048AC2L CR-U048AC3 CR-U048AC3L CR-U048DC2 CR-U048DC2L CR-U048DC2LD CR-U048DC3 CR-U048DC3L CR-U048DC3LD Order code 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405662R1000 1SVR405663R0000 1SVR405663R1000 1SVR405663R4000 1SVR405664R0000 1SVR405665R0000 1SVR405665R1000 1SVR405665R4000 1SVR405665R4100 1SVR405664R4000 1SVR405664R4100 1SVR405664R1000 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 1SVR405664R0100 1SVR405665R0100 1SVR405665R1100 1SVR405664R1100 1SVR405667R0000 1SVR405621R0300 1SVR405622R0300 1SVR405621R4000 1SVR405621R4100 1SVR405621R4400 1SVR405622R4000 1SVR405622R4100 1SVR405622R4400 1SVR405621R0000 1SVR405621R0100 1SVR405622R0000 1SVR405622R0100 1SVR405621R1000 1SVR405621R1100 1SVR405621R1400 1SVR405622R1000 1SVR405622R1100 1SVR405623R1100 1SVR405621R5000 1SVR405621R5100 1SVR405622R5000 1SVR405622R5100 1SVR405621R6000 1SVR405621R6100 1SVR405621R6400 1SVR405622R6000 1SVR405622R6100 1SVR405622R6400 Page 408 408 408 408 408 408 408 408 409 409 409 409 408 408 408 409 409 409 408 409 409 408 409 406 407 406 406 407 406 407 407 406 406 406 407 406 406 407 406 407 407 406 406 406 407 406 406 407 406 407 407 Type CR-U060AC3 CR-U110AC2 CR-U110AC2L CR-U110AC3 CR-U110AC3L CR-U110DC2 CR-U110DC2L CR-U110DC2LD CR-U110DC3 CR-U110DC3L CR-U110DC3LD CR-U120AC2 CR-U120AC2L CR-U120AC3 CR-U120AC3L CR-U125DC3 CR-U220DC2 CR-U220DC2L CR-U220DC3 CR-U220DC3L CR-U230AC2 CR-U230AC2L CR-U230AC3 CR-U230AC3L CR-U2S CR-U2SM CR-U3E CR-U3S CR-U3SM CR-UH CT- MXS.22S CT-AHC.12 CT-AHC.22 CT-AHD.12 CT-AHD.22 CT-AHS.22P CT-AHS.22S CT-APS.12P CT-APS.12S CT-APS.21P CT-APS.21S CT-APS.22P CT-APS.22S CT-ARC.12 CT-ARS.11P CT-ARS.11S CT-ARS.21P CT-ARS.21S CT-EBC.12 CT-EBD.12 CT-ERC.12 Order code 1SVR405622R5200 1SVR405621R7000 1SVR405621R7100 1SVR405622R7000 1SVR405622R7100 1SVR405621R8000 1SVR405621R8100 1SVR405621R8400 1SVR405622R8000 1SVR405622R8100 1SVR405622R8400 1SVR405621R2000 1SVR405621R2100 1SVR405622R2000 1SVR405622R2100 1SVR405622R8200 1SVR405621R9000 1SVR405621R9100 1SVR405622R9000 1SVR405622R9100 1SVR405621R3000 1SVR405621R3100 1SVR405622R3000 1SVR405622R3100 1SVR405670R0000 1SVR405670R1100 1SVR405660R0100 1SVR405660R0000 1SVR405660R1100 1SVR405669R0000 1SVR730030R3300 1SVR508110R0000 1SVR508110R0100 1SVR500110R0000 1SVR500110R0100 1SVR740110R3300 1SVR730110R3300 1SVR740180R3100 1SVR730180R3100 1SVR740180R0300 1SVR730180R0300 1SVR740180R3300 1SVR730180R3300 1SVR508120R0000 1SVR740120R3100 1SVR730120R3100 1SVR740120R3300 1SVR730120R3300 1SVR508150R0000 1SVR500150R0000 1SVR508100R0000 463 Page 406 406 406 406 407 406 406 407 406 407 407 406 406 406 407 406 406 406 406 407 406 406 406 407 407 407 407 407 407 407 39 25 25 57 57 40 40 40 40 40 40 40 40 25 40 40 40 40 25 57 25 464 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Product type Type CT-ERC.22 CT-ERD.12 CT-ERD.22 CT-ERS.12P CT-ERS.12S CT-ERS.21P CT-ERS.21S CT-ERS.22P CT-ERS.22S CT-MBS.22P CT-MBS.22S CT-MFC.12 CT-MFC.21 CT-MFD.12 CT-MFD.21 CT-MFS.21P CT-MFS.21S CT-MKC.31 CT-MVS.12P CT-MVS.12S CT-MVS.21P CT-MVS.21S CT-MVS.22P CT-MVS.22S CT-MVS.23P CT-MVS.23S CT-MXS.22P CT-SAC.22 CT-SAD.22 CT-SDC.22 CT-SDD.22 CT-SDS.22P CT-SDS.22S CT-SDS.23P CT-SDS.23S CT-TGC.12 CT-TGC.22 CT-TGD.12 CT-TGD.22 CT-VWC.12 CT-VWD.12 CT-WBS.22P CT-WBS.22S EPD24-TB-101-0.5A EPD24-TB-101-10A EPD24-TB-101-12A EPD24-TB-101-1A EPD24-TB-101-2A EPD24-TB-101-3A EPD24-TB-101-4A EPD24-TB-101-6A Order code 1SVR508100R0100 1SVR500100R0000 1SVR500100R0100 1SVR740100R3100 1SVR730100R3100 1SVR740100R0300 1SVR730100R0300 1SVR740100R3300 1SVR730100R3300 1SVR740010R3200 1SVR730010R3200 1SVR508020R0000 1SVR508020R1100 1SVR500020R0000 1SVR500020R1100 1SVR740010R0200 1SVR730010R0200 1SVR508010R1300 1SVR740020R3100 1SVR730020R3100 1SVR740020R0200 1SVR730020R0200 1SVR740020R3300 1SVR730020R3300 1SVR740021R2300 1SVR730021R2300 1SVR740030R3300 1SVR508210R0100 1SVR500210R0100 1SVR508211R0100 1SVR500211R0100 1SVR740210R3300 1SVR730210R3300 1SVR740211R2300 1SVR730211R2300 1SVR508160R0000 1SVR508160R0100 1SVR500160R0000 1SVR500160R0100 1SVR508130R0000 1SVR500130R0000 1SVR740040R3300 1SVR730040R3300 2CDE601101R2905 2CDE601101R2010 2CDE601101R2012 2CDE601101R2001 2CDE601101R2002 2CDE601101R2003 2CDE601101R2004 2CDE601101R2006 Page 25 57 57 40 40 40 40 40 40 39 39 25 25 57 57 39 39 25 39 39 39 39 39 39 39 39 39 25 57 25 57 40 40 40 40 25 25 57 57 25 57 39 39 352 352 352 352 352 352 352 352 Type EPD24-TB-101-8A EPD-BB500 EPD-SB21 K A1- 8029 K A1- 8030 MA16-1060 MAR.01 MAR.01 MAR.02 MAR.12 MAR.12 MT-150B MT-250B MT-350B OBIC0100-115-230 OBIC0100-24VDC OBIC0100-48-60VUC OBIC0100-5-12VDC OBOA1000-115VUC OBOA1000-230VUC OBOA1000-24VDC OBOA2000-24VDC OBOC2000-115VUC OBOC2000-230VUC OBOC2000-24VDC OBOC2000-24VUC OBOC2000-48-60VUC OBOC2000-5-12VDC OBOC5000-115VUC OBOC5000-24VDC OBRIC0100-115-230 OBRIC0100-24VDC OBRIC0100-48-60VUC OBRIC0100-5-12VDC OBROA1000-24VDC OBROA2000-24VDC OBROC2000-230VUC OBROC2000-24VDC OBROC2000-24VUC OBROC2000-48-60VUC OBROC2000-5-12VDC OBROC5000-230VUC OBROC5000-24VDC RB101R-24VUC RB111-115VUC RB111-230VUC RB111-24VUC RB111R-24VUC RB121-115VUC RB121-12VDC RB121-230VUC Order code 2CDE601101R2008 2CDE605100R0500 2CDE605200R0021 1SFA616920R8029 1SFA616920R8030 1SFA611940R1060 1SVR366017R0100 1SVR366017R0100 1SVR430043R0000 1SVR730006R0000 1SVR730006R0000 1SFA611410R1506 1SFA611410R2506 1SFA611410R3506 1SNA645022R2700 1SNA645021R2600 1SNA645049R1200 1SNA645047R0000 1SNA645062R0700 1SNA645028R0500 1SNA645027R2400 1SNA645029R0600 1SNA645054R0700 1SNA645026R2300 1SNA645051R0400 1SNA645025R2200 1SNA645053R0600 1SNA645050R1700 1SNA645058R1300 1SNA645024R2100 1SNA645522R2100 1SNA645521R2000 1SNA645549R1400 1SNA645547R0200 1SNA645527R2600 1SNA645529R0000 1SNA645526R2500 1SNA645551R0600 1SNA645525R2400 1SNA645553R0000 1SNA645550R1100 1SNA645559R1600 1SNA645524R2300 1SNA645019R0400 1SNA645016R2100 1SNA645017R2200 1SNA645014R2700 1SNA645018R0300 1SNA645003R0500 1SNA645073R0000 1SNA645004R0400 Page 352 352 352 41 41 41 41 242 242 41 242 41 41 41 451 451 451 451 451 451 451 452 451 451 451 451 451 451 451 451 451 451 451 451 451 452 451 451 451 451 451 451 451 442 442 442 442 442 442 442 442 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX 465 -- Index Product type Type RB121-24VDC RB121-24VUC RB121-48-60VUC RB121-60-230VUC RB121G-115VUC RB121G-12VDC RB121G-230VUC RB121G-24VDC RB121G-24VUC RB121G-48-60VUC RB121P-12VDC RB121P-5VDC RB121PG-5VDC RB121R-115VUC RB121R-230VUC RB122G-115VUC RB122G-230VUC RB122G-24VUC RB122G-48-60VUC RB-JB10 RB-JB20 RBR101R-24VUC RBR111-24VUC RBR111R-24VUC RBR121-115VUC RBR121-230VUC RBR121-24VDC RBR121-24VUC RBR121-48-60VUC RBR121-60-230VUC RBR121G-115VUC RBR121G-230VUC RBR121G-24VDC RBR121G-24VUC RBR121G-48-60VUC RBR121P-12VDC RBR121P-5VDC RBR121R-230VUC RBR122G-115VUC RBR122G-230VUC RBR122G-24VUC RBR122G-48-60VUC SC612 SK 615 562-87 SK 615 562-88 Order code 1SNA645071R0000 1SNA645001R0300 1SNA645002R0400 1SNA645020R0100 1SNA645007R0100 1SNA645075R0000 1SNA645008R1200 1SNA645072R0000 1SNA645005R0700 1SNA645006R0000 1SNA645035R2400 1SNA645034R2300 1SNA645036R2500 1SNA645046R0700 1SNA645011R2400 1SNA645041R0200 1SNA645013R2600 1SNA645012R2500 1SNA645040R1500 1SVR406570R0000 1SVR406580R0000 1SNA645519R0600 1SNA645514R2100 1SNA645518R0500 1SNA645503R0700 1SNA645504R0000 1SNA645571R0000 1SNA645501R0500 1SNA645502R0600 1SNA645520R0300 1SNA645507R0300 1SNA645508R1400 1SNA645572R0000 1SNA645505R0100 1SNA645506R0200 1SNA645535R2600 1SNA645534R2500 1SNA645511R2600 1SNA645541R0400 1SNA645513R2000 1SNA645512R2700 1SNA645540R1700 1SNA290474R0200 GJD6155620R0087 GJD6155620R0088 Page 442 442 442 443 443 443 443 443 443 443 442 442 443 443 443 443 443 443 443 452 452 442 442 442 442 442 442 442 442 443 443 443 443 443 443 442 442 443 443 443 443 443 443 41 41 466 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type MT-150B MT-250B MT-350B MA16-1060 K A1- 8029 K A1- 8030 SC612 RB121-24VUC RB121-48-60VUC RB121-115VUC RB121-230VUC RB121G-24VUC RB121G-48-60VUC RB121G-115VUC RB121G-230VUC RB121R-230VUC RB122G-24VUC RB122G-230VUC RB111-24VUC RB111-115VUC RB111-230VUC RB111R-24VUC RB101R-24VUC RB121-60-230VUC OBIC0100-24VDC OBIC0100-115-230 OBOC5000-24VDC OBOC2000-24VUC OBOC2000-230VUC OBOA1000-24VDC OBOA1000-230VUC OBOA2000-24VDC RB121P-5VDC RB121P-12VDC RB121PG-5VDC RB122G-48-60VUC RB122G-115VUC RB121R-115VUC OBIC0100-5-12VDC OBIC0100-48-60VUC OBOC2000-5-12VDC OBOC2000-24VDC OBOC2000-48-60VUC OBOC2000-115VUC OBOC5000-115VUC OBOA1000-115VUC RB121-24VDC RB121G-24VDC RB121-12VDC RB121G-12VDC RBR121-24VUC Order code 1SFA611410R1506 1SFA611410R2506 1SFA611410R3506 1SFA611940R1060 1SFA616920R8029 1SFA616920R8030 1SNA290474R0200 1SNA645001R0300 1SNA645002R0400 1SNA645003R0500 1SNA645004R0400 1SNA645005R0700 1SNA645006R0000 1SNA645007R0100 1SNA645008R1200 1SNA645011R2400 1SNA645012R2500 1SNA645013R2600 1SNA645014R2700 1SNA645016R2100 1SNA645017R2200 1SNA645018R0300 1SNA645019R0400 1SNA645020R0100 1SNA645021R2600 1SNA645022R2700 1SNA645024R2100 1SNA645025R2200 1SNA645026R2300 1SNA645027R2400 1SNA645028R0500 1SNA645029R0600 1SNA645034R2300 1SNA645035R2400 1SNA645036R2500 1SNA645040R1500 1SNA645041R0200 1SNA645046R0700 1SNA645047R0000 1SNA645049R1200 1SNA645050R1700 1SNA645051R0400 1SNA645053R0600 1SNA645054R0700 1SNA645058R1300 1SNA645062R0700 1SNA645071R0000 1SNA645072R0000 1SNA645073R0000 1SNA645075R0000 1SNA645501R0500 Page 41 41 41 41 41 41 443 442 442 442 442 443 443 443 443 443 443 443 442 442 442 442 442 443 451 451 451 451 451 451 451 452 442 442 443 443 443 443 451 451 451 451 451 451 451 451 442 443 442 443 442 Type RBR121-48-60VUC RBR121-115VUC RBR121-230VUC RBR121G-24VUC RBR121G-48-60VUC RBR121G-115VUC RBR121G-230VUC RBR121R-230VUC RBR122G-24VUC RBR122G-230VUC RBR111-24VUC RBR111R-24VUC RBR101R-24VUC RBR121-60-230VUC OBRIC0100-24VDC OBRIC0100-115-230 OBROC5000-24VDC OBROC2000-24VUC OBROC2000-230VUC OBROA1000-24VDC OBROA2000-24VDC RBR121P-5VDC RBR121P-12VDC RBR122G-48-60VUC RBR122G-115VUC OBRIC0100-5-12VDC OBRIC0100-48-60VUC OBROC2000-5-12VDC OBROC2000-24VDC OBROC2000-48-60VUC OBROC5000-230VUC RBR121-24VDC RBR121G-24VDC CP-C.1-A-RU CP-C.1-A-RU-C CP-C.1 24/5.0 CP-C.1 24/5.0-C CP-C.1 24/10.0 CP-C.1 24/10.0-C CP-C.1 24/20.0 CP-C.1 24/20.0-C CP-C.1-A-RU-L CP-C.1 24/5.0-L CP-C.1 24/10.0-L CP-C.1 24/20.0-L MAR.01 MAR.01 CM-HE CM-HC CM-HCT CR-S005VDC1R Order code 1SNA645502R0600 1SNA645503R0700 1SNA645504R0000 1SNA645505R0100 1SNA645506R0200 1SNA645507R0300 1SNA645508R1400 1SNA645511R2600 1SNA645512R2700 1SNA645513R2000 1SNA645514R2100 1SNA645518R0500 1SNA645519R0600 1SNA645520R0300 1SNA645521R2000 1SNA645522R2100 1SNA645524R2300 1SNA645525R2400 1SNA645526R2500 1SNA645527R2600 1SNA645529R0000 1SNA645534R2500 1SNA645535R2600 1SNA645540R1700 1SNA645541R0400 1SNA645547R0200 1SNA645549R1400 1SNA645550R1100 1SNA645551R0600 1SNA645553R0000 1SNA645559R1600 1SNA645571R0000 1SNA645572R0000 1SVR360060R1001 1SVR360060R2001 1SVR360563R1001 1SVR360563R2001 1SVR360663R1001 1SVR360663R2001 1SVR360763R1001 1SVR360763R2001 1SVR361060R1001 1SVR361563R1001 1SVR361663R1001 1SVR361763R1001 1SVR366017R0100 1SVR366017R0100 1SVR402902R0000 1SVR402902R1000 1SVR402902R2000 1SVR405501R1010 Page 442 442 442 443 443 443 443 443 443 443 442 442 442 443 451 451 451 451 451 451 452 442 442 443 443 451 451 451 451 451 451 442 443 342 342 294 294 294 294 294 294 342 294 294 294 41 242 242 242 242 389 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type CR-S005VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1TRI CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S024VADC1CRS CR-S024VADC1CRGS CR-S024VADC1CRZ CR-S024VADC1CRGZ CR-S110VADC1CRS CR-S110VADC1CRGS CR-S110VADC1CRZ CR-S110VADC1CRGZ CR-S230VADC1CRS CR-S230VADC1CRGS CR-S230VADC1CRZ CR-S230VADC1CRGZ CR-SJB20-BLUE CR-SJB20-RED CR-SJB20-BLACK CR-SSEP CR-P024AC1 CR-P024AC1SS62CV CR-P024DC1 CR-P024DC1SS42V CR-P024DC1LC42V CR-P024DC1LC62C CR-P120AC1 CR-P120AC1SS92CV CR-P230AC1 CR-P230AC1LC92CV CR-P230AC1LS CR-P230AC1SS92CV CR-P012DC1 Order code 1SVR405501R1020 1SVR405501R2010 1SVR405501R2020 1SVR405501R3010 1SVR405501R3020 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405510R3050 1SVR405510R3060 1SVR405510R3070 1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405521R5100 1SVR405521R5200 1SVR405521R6100 1SVR405521R6200 1SVR405521R7100 1SVR405521R7200 1SVR405541R3110 1SVR405541R3120 1SVR405541R3210 1SVR405541R3220 1SVR405541R6110 1SVR405541R6120 1SVR405541R6210 1SVR405541R6220 1SVR405541R7110 1SVR405541R7120 1SVR405541R7210 1SVR405541R7220 1SVR405598R0700 1SVR405598R0800 1SVR405598R0900 1SVR405599R0000 1SVR405600R0000 1SVR405600R0010 1SVR405600R1000 1SVR405600R1010 1SVR405600R1011 1SVR405600R1013 1SVR405600R2000 1SVR405600R2010 1SVR405600R3000 1SVR405600R3010 1SVR405600R3011 1SVR405600R3110 1SVR405600R4000 Page 389 389 389 389 389 389 389 389 389 389 389 389 390 390 390 390 390 390 390 390 390 390 389 389 389 389 389 389 389 389 389 389 389 389 390 390 390 390 393 395 393 395 395 395 393 395 393 395 395 395 393 Type CR-P012DC1SS42V CR-P048AC1 CR-P048DC1 CR-P110AC1 CR-P110DC1 CR-P110DC1SS42CV CR-P024AC2 CR-P024AC2SS62CV CR-P012AC2 CR-P024DC2 CR-P024DC2SS42V CR-P024DC2LS42V CR-P024DC2LC42 CR-P024DC2LS42 CR-P120AC2 CR-P120AC2SS92CV CR-P230AC2 CR-P230AC2LS92CV CR-P230AC2LC92 CR-P230AC2SS92CV CR-P012DC2 CR-P012DC2SS42V CR-P048AC2 CR-P048DC2 CR-P110AC2 CR-P110DC2 CR-P110DC2SS42CV CR-P024AC2G CR-P024DC2G CR-P024DC2GLC42V CR-P024DC2GLC62CV CR-P024DC2GLC62C CR-P230AC2G CR-P230AC2GLC92CV CR-P230AC2GLC92C CR-P230AC2GLC92 CR-P110AC2G CR-P024MOS1 CR-P024TRI1 CR-M024AC2 CR-M024AC2L CR-M012AC2L CR-M024DC2 CR-M024DC2L CR-M024DC2LD CR-M120AC2 CR-M120AC2L CR-M230AC2 CR-M230AC2L CR-M012DC2 CR-M012DC2L Order code 1SVR405600R4010 1SVR405600R5000 1SVR405600R6000 1SVR405600R7000 1SVR405600R8000 1SVR405600R8010 1SVR405601R0000 1SVR405601R0010 1SVR405601R0200 1SVR405601R1000 1SVR405601R1010 1SVR405601R1011 1SVR405601R1012 1SVR405601R1013 1SVR405601R2000 1SVR405601R2010 1SVR405601R3000 1SVR405601R3011 1SVR405601R3012 1SVR405601R3110 1SVR405601R4000 1SVR405601R4010 1SVR405601R5000 1SVR405601R6000 1SVR405601R7000 1SVR405601R8000 1SVR405601R8010 1SVR405606R0000 1SVR405606R1000 1SVR405606R1010 1SVR405606R1011 1SVR405606R1013 1SVR405606R3000 1SVR405606R3010 1SVR405606R3012 1SVR405606R3013 1SVR405606R7000 1SVR405610R4060 1SVR405610R4070 1SVR405611R0000 1SVR405611R0100 1SVR405611R0300 1SVR405611R1000 1SVR405611R1100 1SVR405611R1400 1SVR405611R2000 1SVR405611R2100 1SVR405611R3000 1SVR405611R3100 1SVR405611R4000 1SVR405611R4100 467 Page 395 393 393 393 393 395 393 396 393 393 396 396 396 396 393 396 393 396 396 396 393 396 393 393 393 393 396 393 393 396 396 396 393 396 396 396 393 393 393 397 398 398 397 398 399 397 398 397 398 397 398 468 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type CR-M060DC2 CR-M060DC2L CR-M012DC2LD CR-M048AC2 CR-M048AC2L CR-M048DC2 CR-M048DC2L CR-M048DC2LD CR-M110AC2 CR-M110AC2L CR-M110DC2 CR-M110DC2L CR-M125DC2 CR-M125DC2L CR-M110DC2LD CR-M125DC2LD CR-M220DC2 CR-M220DC2L CR-M220DC2LD CR-M024AC3 CR-M024AC3L CR-M012AC3L CR-M024DC3 CR-M024DC3L CR-M024DC3LD CR-M120AC3 CR-M120AC3L CR-M230AC3 CR-M230AC3L CR-M012DC3 CR-M012DC3L CR-M060DC3 CR-M060DC3L CR-M012DC3LD CR-M048AC3 CR-M048AC3L CR-M060AC3 CR-M048DC3 CR-M048DC3L CR-M048DC3LD CR-M110AC3 CR-M110AC3L CR-M110DC3 CR-M110DC3L CR-M125DC3 CR-M125DC3L CR-M110DC3LD CR-M125DC3LD CR-M220DC3 CR-M220DC3L CR-M220DC3LD Order code 1SVR405611R4200 1SVR405611R4300 1SVR405611R4400 1SVR405611R5000 1SVR405611R5100 1SVR405611R6000 1SVR405611R6100 1SVR405611R6400 1SVR405611R7000 1SVR405611R7100 1SVR405611R8000 1SVR405611R8100 1SVR405611R8200 1SVR405611R8300 1SVR405611R8400 1SVR405611R8500 1SVR405611R9000 1SVR405611R9100 1SVR405611R9400 1SVR405612R0000 1SVR405612R0100 1SVR405612R0300 1SVR405612R1000 1SVR405612R1100 1SVR405612R1400 1SVR405612R2000 1SVR405612R2100 1SVR405612R3000 1SVR405612R3100 1SVR405612R4000 1SVR405612R4100 1SVR405612R4200 1SVR405612R4300 1SVR405612R4400 1SVR405612R5000 1SVR405612R5100 1SVR405612R5200 1SVR405612R6000 1SVR405612R6100 1SVR405612R6400 1SVR405612R7000 1SVR405612R7100 1SVR405612R8000 1SVR405612R8100 1SVR405612R8200 1SVR405612R8300 1SVR405612R8400 1SVR405612R8500 1SVR405612R9000 1SVR405612R9100 1SVR405612R9400 Page 397 398 399 397 398 397 398 399 397 398 397 398 397 398 399 399 397 398 399 397 398 398 397 398 399 397 398 397 398 397 398 397 398 399 397 398 397 397 398 399 397 398 397 398 397 398 399 399 397 398 399 Type CR-M024AC4 CR-M024AC4LS62CV CR-M024AC4L CR-M012AC4L CR-M024DC4 CR-M024DC4SS42V CR-M024DC4LS42V CR-M024DC4LC42 CR-M024DC4L CR-M120AC4 CR-M120AC4L CR-M230AC4 CR-M230AC4LS92CV CR-M230AC4LC92 CR-M230AC4L CR-M230AC4SS92CV CR-M012DC4 CR-M012DC4L CR-M060DC4 CR-M060DC4L CR-M012DC4LD CR-M048AC4 CR-M048AC4L CR-M048DC4 CR-M048DC4L CR-M048DC4LD CR-M110AC4 CR-M110AC4L CR-M110DC4 CR-M110DC4L CR-M125DC4 CR-M125DC4L CR-M110DC4LD CR-M125DC4LD CR-M220DC4 CR-M220DC4L CR-M220DC4LD CR-M024DC4LD CR-M024AC4G CR-M024AC4LG CR-M024DC4G CR-M024DC4GLC62CV CR-M024DC4GSS42V CR-M024DC4LG CR-M024DC4LGLC22 CR-M024DC4LDG CR-M024DC4LDGSS CR-M120AC4LG CR-M230AC4G CR-M230AC4LG CR-M230AC4LGLC Order code 1SVR405613R0000 1SVR405613R0010 1SVR405613R0100 1SVR405613R0300 1SVR405613R1000 1SVR405613R1010 1SVR405613R1011 1SVR405613R1012 1SVR405613R1100 1SVR405613R2000 1SVR405613R2100 1SVR405613R3000 1SVR405613R3011 1SVR405613R3012 1SVR405613R3100 1SVR405613R3110 1SVR405613R4000 1SVR405613R4100 1SVR405613R4200 1SVR405613R4300 1SVR405613R4400 1SVR405613R5000 1SVR405613R5100 1SVR405613R6000 1SVR405613R6100 1SVR405613R6400 1SVR405613R7000 1SVR405613R7100 1SVR405613R8000 1SVR405613R8100 1SVR405613R8200 1SVR405613R8300 1SVR405613R8400 1SVR405613R8500 1SVR405613R9000 1SVR405613R9100 1SVR405613R9400 1SVR405614R1100 1SVR405618R0000 1SVR405618R0100 1SVR405618R1000 1SVR405618R1010 1SVR405618R1011 1SVR405618R1100 1SVR405618R1110 1SVR405618R1400 1SVR405618R1410 1SVR405618R2100 1SVR405618R3000 1SVR405618R3100 1SVR405618R3110 Page 397 401 398 398 397 401 401 401 398 397 398 397 402 402 398 402 397 398 397 398 399 397 398 397 398 399 397 398 397 398 397 398 399 399 397 398 399 399 399 400 399 401 401 400 401 400 401 400 399 400 402 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type CR-M230AC4LGSS CR-M230AC4GSS92CV CR-M012DC4LG CR-M060DC4LG CR-M012DC4LDG CR-M012DC4LDGSS CR-M048AC4LG CR-M048DC4LG CR-M110AC4G CR-M110AC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG CR-U024AC2 CR-U024AC2L CR-U012AC2L CR-U024DC2 CR-U024DC2L CR-U024DC2LD CR-U120AC2 CR-U120AC2L CR-U230AC2 CR-U230AC2L CR-U012DC2 CR-U012DC2L CR-U012DC2LD CR-U048AC2 CR-U048AC2L CR-U048DC2 CR-U048DC2L CR-U048DC2LD CR-U110AC2 CR-U110AC2L CR-U110DC2 CR-U110DC2L CR-U110DC2LD CR-U220DC2 CR-U220DC2L CR-U024AC3 CR-U024AC3L CR-U012AC3L CR-U024DC3 CR-U024DC3L CR-U120AC3 CR-U120AC3L CR-U230AC3 CR-U230AC3L CR-U012DC3 CR-U012DC3L CR-U012DC3LD CR-U048AC3 Order code 1SVR405618R3111 1SVR405618R3112 1SVR405618R4100 1SVR405618R4300 1SVR405618R4400 1SVR405618R4410 1SVR405618R5100 1SVR405618R6100 1SVR405618R7000 1SVR405618R7100 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 1SVR405621R0000 1SVR405621R0100 1SVR405621R0300 1SVR405621R1000 1SVR405621R1100 1SVR405621R1400 1SVR405621R2000 1SVR405621R2100 1SVR405621R3000 1SVR405621R3100 1SVR405621R4000 1SVR405621R4100 1SVR405621R4400 1SVR405621R5000 1SVR405621R5100 1SVR405621R6000 1SVR405621R6100 1SVR405621R6400 1SVR405621R7000 1SVR405621R7100 1SVR405621R8000 1SVR405621R8100 1SVR405621R8400 1SVR405621R9000 1SVR405621R9100 1SVR405622R0000 1SVR405622R0100 1SVR405622R0300 1SVR405622R1000 1SVR405622R1100 1SVR405622R2000 1SVR405622R2100 1SVR405622R3000 1SVR405622R3100 1SVR405622R4000 1SVR405622R4100 1SVR405622R4400 1SVR405622R5000 Page 402 402 400 400 400 401 400 400 399 400 400 400 400 406 406 406 406 406 407 406 406 406 406 406 406 407 406 406 406 406 407 406 406 406 406 407 406 406 406 407 407 406 407 406 407 406 407 406 407 407 406 Type CR-U048AC3L CR-U060AC3 CR-U048DC3 CR-U048DC3L CR-U048DC3LD CR-U110AC3 CR-U110AC3L CR-U110DC3 CR-U110DC3L CR-U125DC3 CR-U110DC3LD CR-U220DC3 CR-U220DC3L CR-U024DC3LD CR-PLS CR-PLSX CR-PLC CR-PSS CR-P/M 22 CR-M2SS CR-M2LS CR-M2LC CR-M2SF CR-M3SS CR-M3LS CR-M4SS CR-M4LS CR-M4LC CR-M4SF CR-P/M 42 CR-P/M 42 V CR-P/M 42 B CR-P/M 42 BV CR-P/M 42 C CR-P/M 42 CV CR-P/M 52B CR-P/M 52C CR-P/M 52D CR-P/M 62 CR-P/M 92 CR-P/M 62 V CR-P/M 92 V CR-P/M 62 E CR-P/M 62 EV CR-P/M 62 C CR-P/M 92 C CR-P/M 62 CV CR-P/M 92 CV CR-P/M 62 D CR-P/M 62 DV CR-P/M 72 Order code 1SVR405622R5100 1SVR405622R5200 1SVR405622R6000 1SVR405622R6100 1SVR405622R6400 1SVR405622R7000 1SVR405622R7100 1SVR405622R8000 1SVR405622R8100 1SVR405622R8200 1SVR405622R8400 1SVR405622R9000 1SVR405622R9100 1SVR405623R1100 1SVR405650R0000 1SVR405650R0100 1SVR405650R0200 1SVR405650R1000 1SVR405651R0000 1SVR405651R1000 1SVR405651R1100 1SVR405651R1200 1SVR405651R1300 1SVR405651R2000 1SVR405651R2100 1SVR405651R3000 1SVR405651R3100 1SVR405651R3200 1SVR405651R3300 1SVR405652R0000 1SVR405652R1000 1SVR405652R4000 1SVR405652R4100 1SVR405652R9000 1SVR405652R9100 1SVR405653R0000 1SVR405653R1000 1SVR405653R4000 1SVR405654R0000 1SVR405654R0100 1SVR405654R1000 1SVR405654R1100 1SVR405654R4000 1SVR405654R4100 1SVR405655R0000 1SVR405655R0100 1SVR405655R1000 1SVR405655R1100 1SVR405655R4000 1SVR405655R4100 1SVR405656R0000 469 Page 407 406 406 407 407 406 407 406 407 406 407 406 407 407 394 394 394 394 404 403 403 403 403 403 403 403 403 403 403 404 404 404 404 404 404 404 404 404 404 404 404 404 404 404 405 405 405 405 405 405 405 470 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type CR-P/M 72 A CR-P/M 82 CR-PM CR-MM CR-MP CR-PJ CR-MJ CR-PH CR-PH1 CR-MH CR-MH1 CR-U3S CR-U3E CR-U3SM CR-U 21 CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV CR-U 51B CR-U 51C CR-U 51D CR-U 61 CR-U 91 CR-U 61V CR-U 91V CR-U 61E CR-U 61EV CR-U 61C CR-U 91C CR-U 61CV CR-U 91CV CR-U 61D CR-U 61DV CR-U 71 CR-U 71A CR-U 81 CR-U T CR-UH CR-U2S CR-U2SM RB-JB10 RB-JB20 CP-RUD CP-E 24/0.75 CP-E 48/0.62 CP-E 24/1.25 CP-E 48/1.25 CP-E 24/2.5 Order code 1SVR405656R1000 1SVR405656R2000 1SVR405658R0000 1SVR405658R1000 1SVR405658R2000 1SVR405658R5000 1SVR405658R6000 1SVR405659R0000 1SVR405659R0100 1SVR405659R1000 1SVR405659R1100 1SVR405660R0000 1SVR405660R0100 1SVR405660R1100 1SVR405661R0000 1SVR405662R0000 1SVR405662R1000 1SVR405662R4000 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405663R0000 1SVR405663R1000 1SVR405663R4000 1SVR405664R0000 1SVR405664R0100 1SVR405664R1000 1SVR405664R1100 1SVR405664R4000 1SVR405664R4100 1SVR405665R0000 1SVR405665R0100 1SVR405665R1000 1SVR405665R1100 1SVR405665R4000 1SVR405665R4100 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 1SVR405667R0000 1SVR405669R0000 1SVR405670R0000 1SVR405670R1100 1SVR406570R0000 1SVR406580R0000 1SVR423418R9000 1SVR427030R0000 1SVR427030R2000 1SVR427031R0000 1SVR427031R2000 1SVR427032R0000 Page 405 405 394 403 403 394 403 394 394 403 403 407 407 407 408 408 408 408 408 408 408 408 408 408 408 408 408 408 408 408 409 409 409 409 409 409 409 409 409 409 407 407 407 452 452 342 260 260 260 260 260 Type CP-E 12/2.5 CP-E 5/3.0 CP-E 24/5.0 CP-E 48/5.0 CP-E 24/10.0 CP-E 12/10.0 CP-E 48/10.0 CP-E 24/20.0 CP-D 24/0.42 CP-D 12/0.83 CP-D 24/1.3 CP-D 12/2.1 CP-D 24/2.5 CP-D 24/4.2 CP-D RU CP-T 24/5.0 CP-T 48/5.0 CP-T 24/10.0 CP-T 48/10.0 CP-T 24/20.0 CP-T 48/20.0 CP-T 24/40.0 CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 CP-B EXT.2 COV.01 ADP.01 ADP.01 MAR.02 COV.02 ADP.02 CM-SE-300 CM-SE-600 CM-SE-1000 CM-KH-3 CM-AH-3 CM-GM-1 CM-CT 50/1 CM-CT 75/1 CM-CT 100/1 CM-CT 150/1 CM-CT 200/1 CM-CT 50/5 CM-CT 75/5 CM-CT 100/5 CM-CT 150/5 CM-CT 200/5 CM-CT 300/1 CM-CT 400/1 CM-CT 500/1 Order code 1SVR427032R1000 1SVR427033R3000 1SVR427034R0000 1SVR427034R2000 1SVR427035R0000 1SVR427035R1000 1SVR427035R2000 1SVR427036R0000 1SVR427041R0000 1SVR427041R1000 1SVR427043R0100 1SVR427043R1200 1SVR427044R0200 1SVR427045R0400 1SVR427049R0000 1SVR427054R0000 1SVR427054R2000 1SVR427055R0000 1SVR427055R2000 1SVR427056R0000 1SVR427056R2000 1SVR427057R0000 1SVR427060R0300 1SVR427060R1000 1SVR427060R2000 1SVR427065R0000 1SVR430005R0100 1SVR430029R0100 1SVR430029R0100 1SVR430043R0000 1SVR440005R0100 1SVR440029R0100 1SVR450056R0000 1SVR450056R0100 1SVR450056R0200 1SVR450056R6000 1SVR450056R7000 1SVR450056R8000 1SVR450116R1000 1SVR450116R1100 1SVR450116R1200 1SVR450116R1300 1SVR450116R1400 1SVR450116R5000 1SVR450116R5100 1SVR450116R5200 1SVR450116R5300 1SVR450116R5400 1SVR450117R1100 1SVR450117R1200 1SVR450117R1300 Page 260 260 260 260 260 260 260 260 318 318 318 318 318 318 342 280 280 280 280 280 280 280 332 332 332 332 242 41 242 242 242 242 242 242 242 242 242 242 243 243 243 243 243 243 243 243 243 243 243 243 243 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type CM-CT 600/1 CM-CT 300/5 CM-CT 400/5 CM-CT 500/5 CM-CT 600/5 CM-CT A CM-IWM.10 CM-IWM.11 CT-MFD.12 CT-MFD.21 CT-ERD.12 CT-ERD.22 CT-AHD.12 CT-AHD.22 CT-VWD.12 CT-EBD.12 CT-TGD.12 CT-TGD.22 CT-SAD.22 CT-SDD.22 CT-MKC.31 CT-MFC.12 CT-MFC.21 CT-ERC.12 CT-ERC.22 CT-AHC.12 CT-AHC.22 CT-ARC.12 CT-VWC.12 CT-EBC.12 CT-TGC.12 CT-TGC.22 CT-SAC.22 CT-SDC.22 CM-MSE CM-MSE CM-MSE CM-PFE CM-PFE.2 CM-ENE MAX CM-ENE MIN CM-ENE MAX CM-ENE MIN CM-ENE MAX CM-ENE MIN CM-PVE CM-PVE CM-PBE CM-PBE CM-UFD.M31 CM-UFD.M33 Order code 1SVR450117R1400 1SVR450117R5100 1SVR450117R5200 1SVR450117R5300 1SVR450117R5400 1SVR450118R1000 1SVR470670R1000 1SVR470670R1100 1SVR500020R0000 1SVR500020R1100 1SVR500100R0000 1SVR500100R0100 1SVR500110R0000 1SVR500110R0100 1SVR500130R0000 1SVR500150R0000 1SVR500160R0000 1SVR500160R0100 1SVR500210R0100 1SVR500211R0100 1SVR508010R1300 1SVR508020R0000 1SVR508020R1100 1SVR508100R0000 1SVR508100R0100 1SVR508110R0000 1SVR508110R0100 1SVR508120R0000 1SVR508130R0000 1SVR508150R0000 1SVR508160R0000 1SVR508160R0100 1SVR508210R0100 1SVR508211R0100 1SVR550800R9300 1SVR550801R9300 1SVR550805R9300 1SVR550824R9100 1SVR550826R9100 1SVR550850R9400 1SVR550850R9500 1SVR550851R9400 1SVR550851R9500 1SVR550855R9400 1SVR550855R9500 1SVR550870R9400 1SVR550871R9500 1SVR550881R9400 1SVR550882R9500 1SVR560730R3401 1SVR560730R3402 Page 243 243 243 243 243 243 161 161 57 57 57 57 57 57 57 57 57 57 57 57 25 25 25 25 25 25 25 25 25 25 25 25 25 25 190 190 190 113 113 229 229 229 229 229 229 113 113 113 113 145 145 Type CM-UFD.M22M CM-UFD.M31M CM-UFD.M33M CM-UFD.M34M COV.11 COV.11 MAR.12 MAR.12 CT-MFS.21S CT-MBS.22S CT-MVS.21S CT-MVS.12S CT-MVS.22S CT-MVS.23S CT- MXS.22S CT-WBS.22S CT-ERS.21S CT-ERS.12S CT-ERS.22S CT-AHS.22S CT-ARS.11S CT-ARS.21S CT-APS.21S CT-APS.12S CT-APS.22S CT-SDS.22S CT-SDS.23S CM-IWS.1S CM-IWS.2S CM-MSS.12S CM-MSS.22S CM-MSS.13S CM-MSS.23S CM-MSS.32S CM-MSS.41S CM-MSS.51S CM-MSS.31S CM-MSS.33S CM-MSS.11S CM-MSS.21S CM-TCS.11S CM-TCS.12S CM-TCS.13S CM-TCS.21S CM-TCS.22S CM-TCS.23S CM-EFS.2S CM-SFS.21S CM-SFS.22S CM-PAS.31S CM-PAS.41S Order code 1SVR560731R3700 1SVR560731R3701 1SVR560731R3702 1SVR560731R3703 1SVR730005R0100 1SVR730005R0100 1SVR730006R0000 1SVR730006R0000 1SVR730010R0200 1SVR730010R3200 1SVR730020R0200 1SVR730020R3100 1SVR730020R3300 1SVR730021R2300 1SVR730030R3300 1SVR730040R3300 1SVR730100R0300 1SVR730100R3100 1SVR730100R3300 1SVR730110R3300 1SVR730120R3100 1SVR730120R3300 1SVR730180R0300 1SVR730180R3100 1SVR730180R3300 1SVR730210R3300 1SVR730211R2300 1SVR730660R0100 1SVR730670R0200 1SVR730700R0100 1SVR730700R0200 1SVR730700R2100 1SVR730700R2200 1SVR730712R0200 1SVR730712R1200 1SVR730712R1300 1SVR730712R1400 1SVR730712R2200 1SVR730720R1400 1SVR730722R1400 1SVR730740R0100 1SVR730740R0200 1SVR730740R0300 1SVR730740R9100 1SVR730740R9200 1SVR730740R9300 1SVR730750R0400 1SVR730760R0400 1SVR730760R0500 1SVR730774R1300 1SVR730774R3300 471 Page 145 145 145 145 41 242 41 242 39 39 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 40 40 161 161 190 190 190 190 190 190 190 190 190 190 190 209 209 209 209 209 209 89 87 87 113 113 472 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX -- Index Order code Type CM-PSS.31S CM-PSS.41S CM-PVS.31S CM-PVS.81S CM-PVS.41S CM-PFS.S CM-ESS.1S CM-ESS.2S CM-ESS.MS CM-ESS.1S CM-ESS.2S CM-ESS.1S CM-ESS.2S CM-SRS.11S CM-SRS.12S CM-SRS.21S CM-SRS.22S CM-SRS.M1S CM-SRS.M2S CM-SRS.11S CM-SRS.12S CM-SRS.21S CM-SRS.22S CM-SRS.11S CM-SRS.12S CM-SRS.21S CM-SRS.22S CM-ENS.11S CM-ENS.21S CM-ENS.31S CM-ENS.11P CM-ENS.23S CM-MPS.31S CM-MPS.41S CM-MPS.43S CM-MPS.11S CM-MPS.21S CM-MPS.23S CT-MFS.21P CT-MBS.22P CT-MVS.21P CT-MVS.12P CT-MVS.22P CT-MVS.23P CT-MXS.22P CT-WBS.22P CT-ERS.21P CT-ERS.12P CT-ERS.22P CT-AHS.22P CT-ARS.11P Order code 1SVR730784R2300 1SVR730784R3300 1SVR730794R1300 1SVR730794R2300 1SVR730794R3300 1SVR730824R9300 1SVR730830R0300 1SVR730830R0400 1SVR730830R0500 1SVR730831R0300 1SVR730831R0400 1SVR730831R1300 1SVR730831R1400 1SVR730840R0200 1SVR730840R0300 1SVR730840R0400 1SVR730840R0500 1SVR730840R0600 1SVR730840R0700 1SVR730841R0200 1SVR730841R0300 1SVR730841R0400 1SVR730841R0500 1SVR730841R1200 1SVR730841R1300 1SVR730841R1400 1SVR730841R1500 1SVR730850R0100 1SVR730850R0200 1SVR730850R0300 1SVR730850R2100 1SVR730850R2200 1SVR730884R1300 1SVR730884R3300 1SVR730884R4300 1SVR730885R1300 1SVR730885R3300 1SVR730885R4300 1SVR740010R0200 1SVR740010R3200 1SVR740020R0200 1SVR740020R3100 1SVR740020R3300 1SVR740021R2300 1SVR740030R3300 1SVR740040R3300 1SVR740100R0300 1SVR740100R3100 1SVR740100R3300 1SVR740110R3300 1SVR740120R3100 Page 113 113 113 113 113 113 89 89 89 89 89 89 89 87 87 87 87 87 87 87 87 87 87 87 87 87 87 229 229 229 229 229 115 115 115 115 115 115 39 39 39 39 39 39 39 39 40 40 40 40 40 Type CT-ARS.21P CT-APS.21P CT-APS.12P CT-APS.22P CT-SDS.22P CT-SDS.23P CM-IWS.1P CM-IWS.2P CM-MSS.12P CM-MSS.22P CM-MSS.13P CM-MSS.23P CM-MSS.32P CM-MSS.41P CM-MSS.51P CM-MSS.31P CM-MSS.33P CM-MSS.11P CM-MSS.21P CM-TCS.11P CM-TCS.12P CM-TCS.13P CM-TCS.21P CM-TCS.22P CM-TCS.23P CM-EFS.2P CM-SFS.21P CM-PAS.31P CM-PAS.41P CM-PSS.31P CM-PSS.41P CM-PVS.31P CM-PVS.81P CM-PVS.41P CM-PFS.P CM-ESS.1P CM-ESS.2P CM-ESS.MP CM-ESS.1P CM-ESS.2P CM-ESS.1P CM-ESS.2P CM-SRS.11P CM-SRS.21P CM-SRS.M1P CM-SRS.11P CM-SRS.21P CM-SRS.11P CM-SRS.21P CM-ENS.13S CM-ENS.21P Order code 1SVR740120R3300 1SVR740180R0300 1SVR740180R3100 1SVR740180R3300 1SVR740210R3300 1SVR740211R2300 1SVR740660R0100 1SVR740670R0200 1SVR740700R0100 1SVR740700R0200 1SVR740700R2100 1SVR740700R2200 1SVR740712R0200 1SVR740712R1200 1SVR740712R1300 1SVR740712R1400 1SVR740712R2200 1SVR740720R1400 1SVR740722R1400 1SVR740740R0100 1SVR740740R0200 1SVR740740R0300 1SVR740740R9100 1SVR740740R9200 1SVR740740R9300 1SVR740750R0400 1SVR740760R0400 1SVR740774R1300 1SVR740774R3300 1SVR740784R2300 1SVR740784R3300 1SVR740794R1300 1SVR740794R2300 1SVR740794R3300 1SVR740824R9300 1SVR740830R0300 1SVR740830R0400 1SVR740830R0500 1SVR740831R0300 1SVR740831R0400 1SVR740831R1300 1SVR740831R1400 1SVR740840R0200 1SVR740840R0400 1SVR740840R0600 1SVR740841R0200 1SVR740841R0400 1SVR740841R1200 1SVR740841R1400 1SVR740850R0100 1SVR740850R0200 Page 40 40 40 40 40 40 161 161 190 190 190 190 190 190 190 190 190 190 190 209 209 209 209 209 209 89 87 113 113 113 113 113 113 113 113 89 89 89 89 89 89 89 87 87 87 87 87 87 87 229 229 ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX 473 -- Index Order code Type CM-ENS.31P CM-ENS.13P CM-ENS.23P CM-MPS.31P CM-MPS.41P CM-MPS.43P CM-MPS.11P CM-MPS.21P CM-MPS.23P COV.12 CM-MPN.52S CM-MPN.62S CM-MPN.72S CM-IWN.1S CM-IVN.S CM-MPN.52P CM-MPN.62P CM-MPN.72P CM-IWN.1P CM-IVN.P EPD24-TB-101-1A EPD24-TB-101-2A EPD24-TB-101-3A EPD24-TB-101-4A EPD24-TB-101-6A EPD24-TB-101-8A EPD24-TB-101-10A EPD24-TB-101-12A EPD24-TB-101-0.5A EPD-BB500 EPD-SB21 C011-70 C011-80 C011-90 C011-100 C011-110 C011-120 C011-130 C011-150 C011-160 C011-170 C011-140 C011-3-150 SK 615 562-87 SK 615 562-88 Order code 1SVR740850R0300 1SVR740850R2100 1SVR740850R2200 1SVR740884R1300 1SVR740884R3300 1SVR740884R4300 1SVR740885R1300 1SVR740885R3300 1SVR740885R4300 1SVR750005R0100 1SVR750487R8300 1SVR750488R8300 1SVR750489R8300 1SVR750660R0200 1SVR750669R9400 1SVR760487R8300 1SVR760488R8300 1SVR760489R8300 1SVR760660R0200 1SVR760669R9400 2CDE601101R2001 2CDE601101R2002 2CDE601101R2003 2CDE601101R2004 2CDE601101R2006 2CDE601101R2008 2CDE601101R2010 2CDE601101R2012 2CDE601101R2905 2CDE605100R0500 2CDE605200R0021 GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110003R0011 GHC0110033R0008 GJD6155620R0087 GJD6155620R0088 Page 229 229 229 115 115 115 115 115 115 242 115 115 115 161 161 115 115 115 161 161 352 352 352 352 352 352 352 352 352 352 352 191 191 191 191 191 191 191 191 191 191 191 191 41 41 -- ABB STOTZ-KONTAKT GmbH Eppelheimer Strasse 82 69123 Heidelberg Germany You can find the address of your local sales organization on the ABB homepage abb.com/lowvoltage 2CDC110004C0210 Rev. E (01/2020) -- We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG Copyright© 2020 ABB AG All rights reservedAdobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)