ABB Time relays: CT-C, CT-S, CT-D ranges

Electronic timers, time relays, CT-C, CT-S, CT-D

ABB Time relays - RS Components

Automatic and manual device self-test ... Control input (manual/auto reset) ... Automatic. - Manual. - Remote. • Rated control supply voltages. - 24 V AC/DC.

ABB Time relays: CT-C, CT-S, CT-D ranges

1010-elec-prod-relay-20
--
C ATA LO G
Electronic relays and controls Offer overview and technical data
· Interface relays and optocouplers · Time relays · Primary switch mode power supplies · Measuring and monitoring relays

2

ELECTRONIC RELAYS AND CONTROLSCATALOG

-- ABB has the industry's most comprehensive range of time relays measuring and monitoring relays, interface relays and power supplies ­ helping you to source all critical components from a single global supplier.

Increase the reliability of process equipment with control devices that provide intelligent signals and smart adjustments that help you achieve maximum system availability.

ELECTRONIC RELAYS AND CONTROLSCATALOG

3

-- Electronic relays and controls
Table of contents

4

Overview

13

Time relays

73

Measuring and

monitoring relays

247

Primary switch mode

power supplies

361

Interface relays and

optocouplers

458

Index

4

ELECTRONIC RELAYS AND CONTROLSCATALOG

-- Interface relays and optocouplers A proven technology used worldwide

Relays are universally applicable and are utilized in a diverse array of applications. They are a significant element in contemporary industrial processes and are used in applications where galvanic isolation, signal separation, voltage coupling and signal amplification are required.
Optocouplers are predominantly used in applications where a high switching frequency is necessary. Furthermore, optocouplers do not contain any moving parts and are therefore bounce-free, immune to vibrations and possess a long electrical life. This wide selection of relays adheres to the highest global standards and satisfies the requirements for a diverse number of applications and needs.

ABB offers a complete range of interface relays and optocouplers for increased flexibility and choice. This portfolio includes pluggable relays for easy interchangeability and optocouplers for an extended electrical life. The portfolio includes electromechanical relays and optocouplers - the electromechanical relays operate using an electromagnetic field, whereas optocouplers use light.

Billions
of relays operate and interface between control circuits and electrical loads

Sensor

110 V AC 230 V AC

Motor

380 V AC

Interface relay Input
24 V DC

Controller (PLC)

Contactor
110 V AC 230 V AC

24 V DC out Interface relay

ELECTRONIC RELAYS AND CONTROLSCATALOG

5

--
Time relays Have the perfect timing- everywhere

Available in three different ranges to cover every application, the CT range time relays are used to provide reliable timing functions worldwide. In both industrial and building applications, the time relays of the CT range have proven their excellent functionality in daily use under the toughest conditions.
Choose ABB as the partner for all your low voltage timing control needs to leverage our wide variety of product options. From economic to high-end solutions ­ the range offers maximum value. Time relays are found everywhere, for example in air conditioning systems, heaters and fans in industrial and in residential buildings . On-delay, off-delay and a range of other functions cover all requirements.

Shock
and vibration resistant CT-S relays are perfect for use in rolling stock

· Control panels · Pump controls · Star-delta motor starting · Movable equipment like
cranes · Machine tools · Automatic doors · Car park barriers · Assembly machines · HVAC

· Compressor controls · Transportation · Industrial refrigeration · Packaging machines · Backing ovens · Water and wastewater · Wind · Industrial cleaning
processes

6

ELECTRONIC RELAYS AND CONTROLSCATALOG

-- Primary switch mode power supplies Excellent reliability in harsh environments

Available in four different ranges to cover every application requirement, ABB's CP range power supplies are used to power valuable assets worldwide.

Emobility

Emergency lighting

LED lighting

Communication

Printing industry

Food industry

Escalators

Packaging industry
Elevators

Choose ABB as your power supply partner and leverage our wide variety of product options. From economic to high-end solutions, the CP range offers maximum value. Their excellent reliability in daily use is well proven even under the toughest of conditions.

ELECTRONIC RELAYS AND CONTROLSCATALOG

7

--
Measuring and monitoring relays Increase process availability and take action

The relays inform users about abnormal conditions and allow them to take necessary corrective actions before severe and costly failures can occur.

Measuring and monitoring relays monitor and detect operating conditions with regard to phase, current, voltage, frequency, temperature, liquid level or insulation faults. The relays inform users about abnormal conditions and allow them to take necessary corrective actions before severe and costly failures can occur.

ABB offers the broadest range of measuring and monitoring relays in the industry - so you can source your critical components from a global supplier. Increase the reliability of your process equipment with controllers that deliver intelligent signals and settings to ensure maximum availability. Ensure continuous operation, engineer time savings and benefit from ABB's global support for measuring and monitoring relays.

8

ELECTRONIC RELAYS AND CONTROLSCATALOG

-- Electronic relays and controls websites Your one-stop shop for product information
On our web site you will also find the products in this catalog together with the current life cycle status, data sheets, certificates and tools.

3D data

Life cycle information

Coordination tables (SOC)

E-configure

Certificates

new.abb.com/low-voltage/products/electronicrelays

ELECTRONIC RELAYS AND CONTROLSCATALOG

9

Marketing material More brochures, catalogs and other tools about electronic relays and control products in rail applications, explosive atmospheres, as well as information about applications, safety products and motor protection and control products are available online.
Online data sheets For detailed product information, use the order code to access the online data sheets as in the following example:
new.abb.com/products/1SVR740110R3300

10

ELECTRONIC RELAYS AND CONTROLSCATALOG

ELECTRONIC RELAYS AND CONTROLSCATALOG

11

-- ABB Connect Your digital assistant
Connect to your electrification solutions with your digital assistant, access the latest news, and create your own digital workspace; search 'ABB Connect' on the Apple App Store, Google Play Store or Microsoft Store and download today.

Find the latest product details

Make your phone or tablet your workspace

new.abb.com/low-voltage/service/abb-connect

Tap and stay connected to all the latest information

12

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

13

-- Time relays Table of contents

15

Time relays for industrial

applications

21

CT-C range

33

CT-S range

51

Time relays for building

applications

54

CT-D range

65

Timing functions

14

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

15

-- Time relays for industrial applications Table of contents

16

Offer overview

17

Type selection

19

Applications

21

CT-C range

22

Benefits and advantages

23

Operating controls

24

Selection table

25

Ordering details

26

Technical data

30

Technical diagrams

33

CT-S range

34

Benefits and advantages

38

Selection table

39

Ordering details

42

Technical data

46

Technical diagrams

16

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- Time relays for industrial applications Offer overview

CT-C: the compact range The CT-C range combines lower cost with higher value and performance by offering essential functions in a space-saving 17.5 mm housing. The range offers a choice of 11 devices, including single and multifunctional types, with timing functions that range from 0.05 seconds to 100 hours. Equipped with a wide voltage range, the CT-C range is suitable for a huge variety of applications worldwide.

CT-S: the high-performance range The advanced CT-S range is ABB s universal range of electronic timers. It includes 22 single-function devices and 16 multifunction time relays, offering flexibility in operation with up to 13 functions. The devices feature seven or ten time ranges, adjustable from 0.05 seconds to 300 hours. Additionally, every device is available in two different connection technologies: familiar double-chamber cage connection terminals (screw terminals) and ABB's vibration-resistant Easy Connect technology (push-in terminals).

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

17

-- Time relays for industrial applications Type selection

Timing function

A

ON-delay

multi-functional CT-C CT-MFC, CT-MKC

single-functional CT-ERC

multi-functional

single-functional

CT-S

CT-MVS, CT-MFS, CT-MBS, CT-ERS CT-WBS

B

OFF-delay

AB ON- and OFF-delay

CT-MFC, CT-MKC, CT-ARC

CA Impulse-ON

CT-MFC, CT-MKC

CB Impulse-OFF

CE DA DB DE
ED
H F

Impulse-ON and OFF Flasher starting with ON Flasher staring with OFF Flasher starting with ON or OFF Pulse generator starting with ON or OFF Pulse former Star-delta change-over

CT-MFC, CT-MKC, CT-ARC CT-MFC, CT-MKC CT-MFC, CT-MKC
CT-MFC, CT-MKC

CT-AHC CT-VWC
CT-EBC CT-EBC CT-TGC CT-SDC, CT-SAC

CT-MVS, CT-MFS, CT-MBS CT-APS, CT-AHS, CT-ARS
CT-MVS, CT-MXS, CT-MFS, CT-MBS CT-MVS, CT-MFS, CT-MBS, CT-WBS CT-MVS, CT-MFS, CT-MBS
CT-MXS CT-MFS, CT-MBS, CT-WBS CT-MFS, CT-MBS, CT-WBS CT-MVS
CT-MXS
CT-MVS, CT-MFS, CT-MBS CT-SDS

FC A+

Star-delta change-over with impulse
AC BC G further functions (depending on device)

CT-MVS.2x, CT-MFS, CT-MBS
CT-MVS, CT-MXS, CT-MFS, CT-MBS, CT-WBS

A detailed explanation of the different timing functions can be found in the chapter "Timing functions".

-- Synonyms
Used expression 1 c/o contact 2 c/o contacts voltage-related volt-free

Alternative expression(s) SPDT DPDT wet / non-floating dry / floating

18

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

19

-- Time relays for industrial applications Applications

ABB offers a wide selection of time relays ­ from economic to high-end ­ to suit every application for businesses worldwide. ABB time relays provide simple, reliable and economical control solutions in all types of panel. They are typically used in industrial applications and OEM equipment, providing time-delayed switching to start a motor, control a load or manage a process.

Remote control of time delays with a remote potentiometer.

Cyclic switching of machinery, for example the weekly startup of a fan to prevent them sticking or the flushing of pipes to keep them clear.

Lighting control, for example the delayed switching of multiple rows of lamps in production facilities or greenhouses.

Time controlled start up or shut down of machinery equipment, for example the delayed switch off of conveyor belts or the successive shut down of a plant.

Alarm triggering in case of fault detection, for example to allow the flashing of a lamp in industrial applications or rolling stock.

Star-delta motor starting to reduce starting current with changeover delay to prevent interphase short-circuits.

Have the perfect timing everywhere with ABB's time relays:

· Control panels · Pump controls · Star-delta motor starting · Movable equipment e.g. cranes · Machine tools · Automatic doors

· Car park barriers · Assembly machines · HVAC · Compressor controls · Transportation · Industrial refrigeration

· Packaging machines · Backing ovens · Water and wastewater · Wind · Industrial cleaning processes

20

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

21

-- CT-C range Table of contents

22

Benefits and advantages

23

Operating controls

24

Selection table

25

Ordering details

26

Technical data

30

Technical diagrams

22

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-C range Benefits and advantages

The CT-C range combines lower cost with higher value and performance by offering essential functions in a 17.5 mm housing, freeing up room in any control cabinet. The range includes 11 devices, offering both single and multifunctional types, with a time range from 0.05 seconds to 100 hours. Equipped with wide voltage ranges, CT-C time relays allow for use across a huge variety of applications worldwide.

Space savings

With a width of just 17.5 mm, the CT-C range is 22% smaller than standard industrial housings for time relays. Its reduced overall footprint saves space in control cabinets. For more flexibility both 1 c/o and 2 c/o output versions are offered in the compact housing.

Cost effective solution

The CT-C range is an economical range that combines lower cost with higher value and performance. It suits basic applications where a time relay is needed, while offering improved functionality in each device.

Optimized logistics

By combining more functions into each device, the CT-C range makes it possible to reduce stock by up to 75% compared to other ranges. All devices in the CT-C range offer a wide supply voltage range as well as a wide time setting range from 0.05 seconds to 100 hours. This significantly reduces order code variance, making the range more compact with just 11 order codes covering every requirement.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

23

-- CT-C range Operating controls

Connection terminals Wide terminal spacing makes wiring connections easier: 2 x 1.5 mm2 (2 x 16 AWG) with wire end ferrules or 2 x 2.5 mm2 (2 x 14 AWG) without ferrules.

Width 17.5 mm With a width of just 17.5mm, CT-C time relays are ideal for installations with limited space.
Control input to start timing

Preselection of the time range
Direct reading scales Direct setting of the time delay without any additional calculation provides accurate time delay adjustment.

Selection of the timing

function

A

ON-delay

B

OFF-delay with

aux. voltage

CA Impulse-ON

CB DA

Impulse-OFF with aux. voltage
Flasher starting with ON

DB Flasher starting with OFF

H

Pulse former

Fine adjustment of the time delay
LEDs for status indication All actual operational states are displayed by front-facing LEDs, simplifying commissioning and troubleshooting. · U - green LED:
V control supply voltage applied / W timing · R, R1, R2 - yellow LED: V output relay energized

24

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-C range Selection table

Order number 1SVR508010R1300 1SVR508020R0000 1SVR508020R1100 1SVR508120R0000 1SVR508100R0000 1SVR508100R0100 1SVR508110R0000 1SVR508110R0100 1SVR508130R0000 1SVR508150R0000 1SVR508160R0000 1SVR508160R0100 1SVR508210R0100 1SVR508211R0100

Type CT-MKC.31 CT-MFC.12 CT-MFC.21 CT-ARC.12 CT-ERC.12 CT-ERC.22 CT-AHC.12 CT-AHC.22 CT-VWC.12 CT-EBC.12 CT-TGC.12 CT-TGC.22 CT-SAC.22 CT-SDC.22

Timing function

ON-delay

AJJJ JJ

OFF-delay with aux. voltage

BJJJ

JJ

OFF-delay w/o aux. voltage

B

J

Impulse-ON

CA J J J

J

Impulse-OFF with aux. voltage

CB J J J

Impulse-OFF w/o aux. voltage

CB

J

Flasher starting with ON

DA J J J

J

Flasher starting with OFF

DB J J J

J

Pulse generator starting with ON or OFF ED

JJ

Pulse former

HJJJ

Star-delta change-over

F

JJ

Features Control input, voltage-related triggering

JJ

JJ JJ

Time range 0.05 s - 100 h 0.05 s - 10 min

JJJ JJJJJJ2 2

J

JJ

Supply voltage 12-240 V AC/DC 24-48 V DC 24-240 V AC

JJ J JJJJJJJJJJJ J JJJJJJJJJJJ

Output

Solid state c/o contact

J
12112121112

n/o contact

22

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

25

-- CT-C range Ordering details

CT-MFC.12
CT-ERC.22 M Control input with
voltage-related triggering - No triggering

2CDC251029V0018

2CDC251030V0018

Description The CT-C range combines lower cost with higher value and performance in a slim 17.5 mm-wide housing. All relays have a wide time setting range from 0.05 seconds up to 100 hours. Combined with a wide voltage range they are the perfect choice for applications worldwide.
-- Ordering details

Timing function

Rated control Time

supply

ranges

voltage

Control Output Type input

Order code

Multi1)

12-240 V AC/DC

7 (0.05 s - M 100 h)

Multi1)

24-240 V AC

M

24-48 V DC

Multi1)

12-240 V

M

AC/DC

Dual2)

24-240 V AC 7 (0.05 s - 24-48 V DC 10 min)

ON-delay 24-240 V AC 7 (0.05 s - 24-48 V DC 100 h)

-

Solid state
1 c/o

CT-MKC.31 1SVR508010R1300 CT-MFC.12 1SVR508020R0000

2 c/o CT-MFC.21 1SVR508020R1100

1 c/o CT-ARC.12 1SVR508120R0000

1 c/o CT-ERC.12 1SVR508100R0000

2 c/o CT-ERC.22 1SVR508100R0100

OFF-delay

M

1 c/o CT-AHC.12 1SVR508110R0000

M

2 c/o CT-AHC.22 1SVR508110R0100

ImpulseON
Flasher3)

-

1 c/o CT-VWC.12 1SVR508130R0000

-

CT-EBC.12 1SVR508150R0000

Pulse generator

2×7 (0.05 s - M 100 h)
M

CT-TGC.124) 1SVR508160R0000 2 c/o CT-TGC.224) 1SVR508160R0100

Star-delta changeover

4 (0.05 s - 10 min)
-

2 n/o CT-SDC.225) 1SVR508211R0100 CT-SAC.226) 1SVR508210R0100

Weight (1 pc)
kg (lb)
0.060 (0.132)
0.060 (0.132)
0.065 (0.143)
0.060 (0.132)
0.060 (0.132)
0.065 (0.143)
0.060 (0.132)
0.065 (0.143)
0.060 (0.132)
0.060 (0.132)
0.060 (0.132)
0.065 (0.143)
0.065 (0.143)

1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former
2) OFF-delay without aux. voltage (True OFF-delay), True Impulse-OFF 3) Flasher starting with ON, Flasher starting with OFF 4) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h 5) Transition time 50 ms fixed 6) Transition time adjustable

26

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-C range Technical data

Data at Ta = 25 °C and rated values, unless otherwise indicated

CT-C with 1 c/o contact

CT-C with 2 c/o contacts

CT-MFC.21

Input circuit - Supply circuit

Rated control supply voltage Us

24-240 V AC / 24-48 V DC

12-240 V AC/DC

Rated control supply voltage US tolerance

-15...+10 %

Rated frequency

DC or 50/60 Hz

Frequency range AC

47-63 Hz

Typical power consumption

max. 3.5 VA

Power failure buffering time

min. 20 ms

Release voltage

> 10 % of the minimum rated control supply voltage Us

Input circuit - Control circuit

Control input, control function

A1-Y1/B1 start timing external

Kind of triggering

voltage-related triggering

Resistance to reverse polarity

yes

Parallel load / polarized

yes / yes

Maximum cable length to the control inputs

50 m  100 pF/m

Minimum control pulse length

20 ms

Control voltage potential

see rated control supply voltage

Timing circuit

Time ranges

7 time ranges 0.05 s - 100 h 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min 5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h

4 time ranges 0.05 s - 10 min (CT-SDC, CT-SAC) 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min

Recovery time

< 50 ms

Accuracy within the rated control supply voltage tolerance

it < 0.005 % / V

Accuracy within the temperature range

it < 0.06 % / °C

Repeat accuracy (constant parameters)

it < ± 0.5 %

Setting accuracy of time delay

± 10% of full-scale value

Star-delta transition time

CT-SDC / CT-SAC fixed 50 ms / adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms

Star-delta transition time tolerance

CT-SDC / CT-SAC ±3 ms

Indication of operational states Control supply voltage / timing

U: green LED V: control supply voltage applied W: timing

Relay energized

R, R1, R2: yellow LED V: output relay energized

Operating elements and controls Adjustment of the time range Fine adjustment of the time value Preselection of the timing function at multifunction devices Adjustment of the transition time

front-face rotary switch, direct reading scales front-face potentiometer front-face rotary switch, direct reading scales CT-SAC front-face potentiometer

Note Technical information for CT-ARC.12 and CT-MKC.31 on request.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

27

-- CT-C range Technical data

CT-C with 1 c/o contact

CT-C with 2 c/o contacts

CT-MFC.21

Output circuit

Kind of output

15-16/18 Relay, 1 c/o contact -

15-16/18; 25-26/28 -

Relay, 2 c/o contacts

17-18; 17-28

Relay, 2 n/o contacts (CT-SDC, CT-SAC)

Contact material

AgNi alloy, Cd free

Rated operational voltage Ue

250 V

Minimum switching voltage / minimum switching current

12 V / 100 mA

Maximum switching voltage / maximum switching current

250 V AC / 6 A

250 V AC / 5 A

Rated operational current Ie

AC-12 (resistive) at 230 V 4 A

4 A

AC-15 (inductive) at 230 V 3 A

3 A

n/o: 3 A n/c: 0.75 A

DC-12 (resistive) at 24 V 4 A

4 A

DC-13 (inductive) at 24 V 2 A

2 A

1 A

AC rating (UL 508)

utilization category (Control Circuit Rating Code) B 300

n/o: B 300 n/c: C 300

max. rated operational voltage 300 V AC

maximum continuous thermal current at B300 5 A

n/o: 5 A

maximum continuous thermal current at C300 -

n/c: 2.5 A

max. making/breaking apparent power at B300 3600 VA / 360 VA

n/o: 3600/360 VA

max. making/breaking apparent power at C300 -

n/c: 1800/180 VA

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

6 A fast-acting

General data

Mean time between failures (MTBF)

on request

Duty cycle

100%

Dimensions

see `Dimensional drawings'

Mounting

DIN rail (IEC/EN 60715), snap-mounting without any tool

Mounting position

any

Minimum distance to other units

horizontal / vertical no / no

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Connecting capacity

fine-stranded with(out) 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) wire and ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG)

rigid 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) 1 x 0.5-4 mm2 (1 x 20-12 AWG)

Stripping length

7 mm (0.28 in)

Tightening torque

0.5-0.8 Nm (4.43-7.08 lb.in)

Environmental data

Ambient temperature range

operation / storage -20 ... +60 °C / -40 ... +85 °C

Climatic class

EC/EN 60068-2-30 3K3

Relative humidity range

25-85%

Vibration, sinusoidal

IEC/EN 60068-2-6 20 m/s²; 10 cycles, 10...150...10 Hz

Shock (half-sine)

IEC/EN 60068-2-27 150 m/s2, 11 ms

Note Technical information for CT-ARC.12 and CT-MKC.31 on request.

28

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-C range Technical data

CT-C with 1 c/o contact

Isolation data Rated insulation voltage Ui
Rated impulse withstand voltage Uimp Power-frequency withstand voltage test(test voltage)

input circuit / output circuit 300 V output circuit 1 / output circuit 2 not available
between all isolated circuits 4 kV; 1.2/50 µs between all isolated circuits 2.5 kV; 50 Hz; 60 s

Basic insulation (IEC/EN 61140)

input circuit / output circuit 300 V

Protective separation (IEC/EN 61140, EN 50178)

input circuit / output circuit 250 V

Pollution degree

3

Overvoltage category

III

Standards / Directives

Standards

IEC/EN 61812-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3 (10 V / m)

electrical fast transient / burst

IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)

surge

IEC/EN 61000-4-5 Level 4 (2 kV L-L)

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 Level 3 (10 V)

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

CT-C with 2 c/o contacts
300 V

CT-MFC.21 300 V

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

29

-- CT-C range Technical diagrams

-- Example of application - Star-delta changeover

L1 F3

95
F2
96
S1 21 0
22

S2 13

53

I

K2

14

54

17
K1T
18

17

13

13

K2

K1

28

14

14

22
K3 21

22
K1 21

K1T N

A1

A1

A1

A1

K1

K3

K2

A2

A2

A2

A2

Y

i

N

Control circuit diagram

L1 L2 L3
135
-F1
246

135
-K2 2 4 6

135

135

-K3 2 4 6 -K1 2 4 6

154
-F2
326

97 95 98 96

-M1

W1

W2

V1

M

V2

U1 3 ~ U2

Power circuit diagram

2CDC252128F0006
2CDC 252 128 F0b06
2CDC253009F0012
2CDC 253 009 F0012

30

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-C range Technical diagrams

-- Connection diagrams
CT-MFC.21

A1

15

25

Y1/ B1 A1 15 25

CT-MFC.12

A1 15 Y1/ B1 A1

Y1/B1 15

A CT-ERC.22

A1

15

25

A1

15

25

A CT-ERC.12

A1

15

A1

15

2CDC252113F0b06
2CDC 252 113 F0b06
2CDC252114F0b06
2CDC 252 114 F0b06
2CDC252115F0b06
2CDC 252 115 F0b06
2CDC252177F0b05
2CDC 252 177 F0b05

A2 16 18 26 28

18

16 Y1/B1

28

26

A2

A1-A2
A1-Y1/B1 15-16/18 25-26/28

Supply: 12-240 V AC/DC Control input
1st c/o contact
2nd c/o contact

A2 16 18

18

16

A2

A1-A2
A1-Y1/B1 15-16/18

Supply: 24-48 V DC or 24-240 V AC
Control input
1st c/o contact

A2 16 18 26 28

18

16

28

26

A2

A1-A2
15-16/18 25-26/28

Supply: 24-48 V DC or 24-240 V AC
1st c/o contact
2nd c/o contact

A2

16 18

18

16

A2

A1-A2 15-16/18

Supply: 24-48 V DC or 24-240 V AC
1st c/o contact

2CDC252116F0b06
2CDC 252 116 F0b06
2CDC252117F0b06
2CDC 252 117 F0b06
2CDC252179F0b05
2CDC 252 179 F0b05

B CT-AHC.22

A1

15

25

Y1/ B1 A1 15 25

B CT-AHC.12

A1 15 Y1/ B1 A1

Y1/B1 15

CA CT-VWC.12

A1

15

A1

15

A2 16 18 26 28

18

16 Y1/B1

28

26

A2

A2 16 18

18

16

A2

A2

16 18

18

16

A2

A1-A2
A1-Y1/B1 15-16/18 25-26/28

Supply: 24-48 V DC or 24240 V AC Control input
1st c/o contact
2nd c/o contact

A1-A2
A1-Y1/B1 15-16/18

Supply: 24-48 V DC or 24240 V AC
Control input
1st c/o contact

A1-A2 15-16/18

Supply: 24-48 V DC or 24240 V AC
1st c/o contact

2CDC252118F0b06
2CDC 252 118 F0b06
2CDC252119F0b06
2CDC 252 119 F0b06
2CDC 252160F0b06
2CDC 252 160 F0b06
2CDC 252160F0b06
2CDC 252 160 F0b06

ED CT-TGC.22

A1

15

25

Y1/ B1 A1 15 25

ED CT-TGC.12

A1 15 Y1/ B1 A1

Y1/B1 15

F CT-SDC.22

A1

17

A1

17

F CT-SAC.22

A1

17

A1

17

A2 16 18 26 28

18

16 Y1/B1

28

26

A2

A1-A2
A1-Y1/B1 15-16/18 25-26/28

Supply: 24-48 V DC or 24-240 V AC Control input
1st c/o contact
2nd c/o contact

A2 16 18

18

16

A2

A2 18 28

28

18

A2

A2 18 28

28

18

A2

A1-A2
A1-Y1/B1 15-16/18

Supply: 24-48 V DC or 24240 V AC Control input
1st c/o contact

A1-A2 17-18 17-28

Supply: 24-48 V DC or 24-240 V AC
1st n/o contact (star contactor)
2nd n/o contact (delta contactor)

A1-A2 17-18 17-28

Supply: 24-48 V DC or 24-240 V AC
1st n/o contact (star contactor)
2nd n/o contact (delta contactor)

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

31

-- CT-C range Technical diagrams

2CDC252124F0206
2CDC 252 124 F0206

2CDC 252 148 F0206

-- Load limit curves AC load (resistive) CT-C.1x
resistive load

AC voltage [V]

CT-C.2x

AC current [A]

22CCDDC2C522502103F1032F108218 DC voltage [V]

DC load (resistive) CT-C.1x
resistive load

CT-C.2x

DC current [A]

2CDC252150F0206

2CDC 252 150 F0206

Derating factor F

-- Derating factor F for inductive AC load
1.0 0.9 0.8 0.7 0.6 0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 
-- Contact lifetime

Switching cycles

2CDC 252 150 F0206

resistive load

resistive load

250 V resistive load

22CCDDCC25225021031F30F2108218 DC voltage [V]

AC voltage [V]

2CDC252150F0206

AC current [A]

-- Wiring notes for devices with control input
A parallel load to the control input is possible
L(+)

A1

Y1/B1

DC current [A]

-- Dimensional drawings in mm and inches

0.69" 17,5

58 2.28" 0.2"
5 43,4 1.71"

A2 N(-)

CT-C devices with 1 c/o contact or 2 n/o contacts

Switching current [A]

0.69" 17,5

58 2.28"

0.2"

5

43,4 1.71"

CT-C devices with 2 c/o contacts

2CDC252148F0206

2CDC252102F0006 2CDC 252 102 F0b06
70 2.76" 45 1.77" 2 2CCDDCC2255212311F301b0F60b06
80 3.15" 45 1.77" 2CCDDCC2522512301F3000F006b06

32

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

33

-- CT-S range Table of contents

34

Benefits and advantages

38

Selection table

39

Ordering details -

multifunctional devices

40

Ordering details -

singlefunctional devices

41

Ordering details - Accessories

42

Technical data

46

Technical diagrams

34

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Benefits and advantages

The advanced CT-S range includes 22 single-function devices and 16 multifunction timers with up to 13 functions. The devices feature seven or ten time ranges, which are adjustable from 0.05 seconds to 300 hours. Every device is available in two different connection technologies: double-chamber cage connection terminals or ABB's vibration-resistant Push-in Technology.

Improve installation efficiency

The CT-S range allows simple tool free mounting and demounting on the DIN rail. Thanks to the easy connect and the double-chamber cage connection technology simplified wiring with or without wire end ferrules is no problem. Both allow simple and easy installation, even in case of different cable diameters.

Reliable in harsh conditions

The CT-S range's extended features make it especially suited for harsh environments. The housing material has the highest UL fire protection classification. All functions are available with Push-in terminals, making operations in environments with high vibrations possible without retightening. Additionally, the CT-S range offers devices with an extended temperature range, running operations in temperatures as low as -40 °C effortlessly. Specific types are tested according to the latest rail industry standards, making them a perfect solution for rolling stock and other rail applications

Global availability

Every device in the CT-S range is designed to provide a wide supply voltage range, making global differences irrelevant. Additionally, the CT-S range meets a broad range of standards and requirements. Together with ABB's global support and sales network, using CT-S gives customers the confidence of worldwide sourcing ­ no matter where they build, install or operate their equipment.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

35

-- CT-S range Operating controls

Control input Starts and pauses timing.
Preselection of time range Direct assignment of the pre-selected time range to the fine adjustment potentiometer scale by multicolor scales
Fine adjustment of the time delay
Selection of the timing function

Connection terminals Screw or push-in connection available.
Remote potentiometer connection possible
2nd contact selectable as an instantaneous contact
LEDs for status indication All actual operational states are displayed by front-face LEDs, thus simplifying commissioning and troubleshooting. · U/T - green LED:
V control supply voltage applied / W timing · R, R1, R2 - yellow LED: V Output relay energized
Integrated marker label Integrated marker labels allow the product to be marked quickly and simply. No additional marker labels are required.

36

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Benefits and advantages

Easy Connect Technology Tool-free wiring and excellent vibration resistance. Easy Connect (Push-in terminals) provide connection of wires up to 2 x 0.5 - 1.5 mm² (2 x 20 -16 AWG), rigid or fine-strand with or without wire end ferrules. The extended type designators for products with push-in terminals are indicated by a P following the extended type designator e.g. CT-xxS.xxP.

2CDC253026F0011

-- 01 Tool-free mounting of wires
-- 02 Wiring of double-cage chamber connection terminals with screw driver

2CDC253025F0011

Double-chamber cage connection terminals According to IEC/EN 60947-1 double-chamber cage connection terminals provide connection of wires up to 2 x 0.5-2.5 mm² (2 x 20-14 AWG) rigid or fine-strand, with or without wire end ferrules. Thanks to the technology, using different cable diameters in one terminal is easy and simple to install. Potential distribution does not require additional terminals. The extended type designators for products with double-chamber cage connection terminals (screw terminals) are indicated by an S following the extended type designator, e.g. CT-xxS.xxS.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

37

-- CT-S range Made for the most extreme conditions

Selected products of the CT-S range comply to the latest rail standards like EN50155. Designed for harsh environments, not only are standard screw type terminals offered ­ push-in terminals with excellent vibration resistance are also available. Perfect for use in rolling stock.

Conductor car · In the event of the press switch not switching off the
auxiliary release pumps of the breaking system, a delayed switch off is triggered by the time relays · While switching between hold-on and start-up coil on the main switch, a time relay can prolong the pulse · The reliable and safe functionality of the compressor is essential for trains

Passenger cars · The control of air flow and interior lighting is controlled by
time relays. A time interval can trigger a delayed start and finish for the air circulation as well as turning on or off the lights inside the cabin · The advanced CT-S range of time relays from ABB is designed to fulfill all necessary requirements for rail applications
-- Electronic relays for railway solutions brochure
For more information about time relays in rolling stock applications visit:
new.abb.com/low-voltage/products/electronicrelays
or scan the QR code

38

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Selection table

CT-SDS.23l 1SVR70211R2300

CT-SDS.22l 1SVR70210R3300

CT-ARS.21l 1SVR70120R3300

CT-ARS.11l 1SVR70120R3100

CT-AHS.22l 1SVR70110R3300

CT-APS.12l 1SVR70180R3100

CT-APS.22l 1SVR70180R3300

CT-APS.21l 1SVR70180R0300

CT-ERS.12l 1SVR70100R3100

CT-ERS.22l 1SVR70100R3300

CT-ERS.21l 1SVR70100R0300

CT-WBS.22l 1SVR70040R3300

CT-MBS.22l 1SVR70010R3200

CT-MFS.21l 1SVR70010R0200

CT-MXS.22l 1SVR70030R3300

CT-MVS.12l 1SVR70020R3100

CT-MVS.23l 1SVR70021R2300

CT-MVS.22l 1SVR70020R3300

CT-MVS.21l 1SVR70020R0200

Order number*

Type*

-- Order number and type All devices are available either with push-in terminals (P-type) or doublechamber cage connection terminals (S-type).

Terminal
Push-in Screw

Type
l = P l = S

Order number  = 4  = 3

Timing function

ON-delay ON-delay, accumulative OFF-delay w. aux. voltage OFF-delay w. aux. voltage, accumulative OFF-delay w/o aux. voltage ON- and OFF-delay, symmetrical ON- and OFF-delay, symmetrical, accumulative ON- and OFF-delay, asymmetrical ON/OFF function Impulse-ON Impulse-ON, accumulative Impulse-OFF w. aux. voltage Impulse-OFF w. aux. voltage, accumulative Impulse-ON and OFF Fixed impulse with adjustable time delay Adjustable impulse with fixed time delay Flasher starting with ON Flasher with reset, starting with ON Flasher starting with OFF Flasher with reset, starting with OFF Flasher starting with ON or OFF Pulse generator starting with ON or OFF Single pulse generator Pulse former Star-delta change-over Star-delta change-over with impulse

AJJJJ JJJJJJ

A(+) J J J J J

BJJJJ JJ

JJJJ

B

J

B

JJ

AB J J J J J J

AB

J

AB

J

GJJJJJJJJ

CA J J J J J J J

CA

J

CB J J J J J J

CB

J

CE

J

AC

J

AC

J

DA

JJJ

DA

JJ

DB

JJJ

DB

JJ

DE J J J J

ED

J

EC

J

HJJJJ JJ

F

JJ

FC J J J

JJ

Features

Control input, voltage-related triggering Control input, volt-free triggering Remote potentiometer connection 2nd c/o contact selectable as instantaneous contact Extended temperature range (-40...+60 °C) Time range

JJJJJ

21

J

2 JJ

J

JJ

J

JJ

JJJ J
J

0.05 s - 10 min 0.05 s - 300 h

JJJJ JJJJ 2 JJJJJJJJJJ

Supply voltage

24-48 V DC 24-240 V AC 24-240 V AC/DC 380-440 V AC

J JJ JJ JJ JJJ J

J JJ JJ JJ JJJ J

J

JJJ

JJ

J

J

Output

c/o contact

22212222221221212

n/o contact

22

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

39

-- CT-S range Ordering details - multifunctional devices

CT-MVS.21P

CT-MBS.22P

M

Control input with

voltage-related

triggering

m

Control input with

volt-free triggering

m / m Two control inputs with volt-free triggering

-

No triggering

2CDC 251 023 V0011

2CDC 251 024 V0011

Description The high-performance CT-S range is ideally suited for universal use and is available with two different connection technologies: · Double-chamber cage connection terminals (Screw terminals) · Easy Connect Technology (Push-in terminals)

-- Ordering details

Timing Rated control Time

function 5) supply

ranges

voltage

Control Output Type input

Order code

Multi

24- 240 V AC/DC

10 (0.05 s - M 300 h)

2 c/o CT-MVS.21S 1) 2) 3) 1SVR730020R0200 CT-MVS.21P 1) 2) 3) 1SVR740020R0200

24-48 V DC, 24-240 V AC

CT-MVS.22S CT-MVS.22P

1SVR730020R3300 1SVR740020R3300

380-440 V AC

CT-MVS.23S

1SVR730021R2300

CT-MVS.23P

1SVR740021R2300

Multi

24-48 V DC, 10 (0.05 s - M 24-240 V AC 300 h)

1 c/o CT-MVS.12S CT-MVS.12P

1SVR730020R3100 1SVR740020R3100

Multi

24-48 V DC, 2×10 (0.05 s M 24-240 V AC - 300 h)

2 c/o CT- MXS.22S 4) 1SVR730030R3300 CT-MXS.22P 4) 1SVR740030R3300

Multi

24- 240 V AC/DC

10 (0.05 s - n / n 300 h)

2 c/o

CT-MFS.21S 1) 2) 3) 1SVR730010R0200 CT-MFS.21P 1) 2) 3) 1SVR740010R0200

24-48 V DC, 10 (0.05 s - n 24-240 V AC 300 h)

2 c/o CT-MBS.22S 2) 3) 1SVR730010R3200 CT-MBS.22P 2) 3) 1SVR740010R3200

Multi

24-48 V DC, 10 (0.05 s - 24-240 V AC 300 h)

2 c/o CT-WBS.22S CT-WBS.22P

1SVR730040R3300 1SVR740040R3300

1) Extended temperature range -40 °C 2) Remote potentiometer connection 3) 2nd c/o contact selectable as instantaneous contact 4) 2 remote potentiometer connections 5) See selection table on previous page
S: Screw connection P: Push-in / easy connect

Weight (1 pc)
kg (lb) 0.148 (0.326)
0.136 (0.30)
0.142 (0.313)
0.131 (0.289)
0.144 (0.317)
0.133 (0.293)
0.107 (0.236)
0.102 (0.225)
0.142 (0.313)
0.131 (0.289)
0.145 (0.32)
0.133 (0.293)
0.14 (0.309)
0.129 (0.284)
0.123 (0.271)
0.115 (0.254)

40

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Ordering details - singlefunctional devices

CT-ERS.21P CT-AHS.22P

CT-SDS.23P

M

Control input with

voltage-related

triggering

m

Control input with

volt-free triggering

m / m Two control inputs with volt-free triggering

-

No triggering

2CDC 251 040 V0011

2CDC 251 033 V0011

2CDC 251 030 V0011

-- Ordering details

Timing function

Rated control Time

supply

ranges

voltage

Control Output Type input

Order code

ON-delay 24-240 V AC/ 10 (0.05 s -

DC

- 300 h)

2 c/o CT-ERS.21S1) 1SVR730100R0300 CT-ERS.21P1) 1SVR740100R0300

24-48 V DC, 24-240 V AC

CT-ERS.22S 1SVR730100R3300 CT-ERS.22P 1SVR740100R3300

24-48 V DC, 24-240 V AC

-

1 c/o CT-ERS.12S 1SVR730100R3100

CT-ERS.12P 1SVR740100R3100

OFFdelay

24-240 V AC/ 10 (0.05 s M

DC

- 300 h)

2 c/o CT-APS.21S1) 1SVR730180R0300 CT-APS.21P1) 1SVR740180R0300

24-48 V DC, 24-240 V AC

CT-APS.22S 1SVR730180R3300 CT-APS.22P 1SVR740180R3300

M

1 c/o CT-APS.12S 1SVR730180R3100

CT-APS.12P 1SVR740180R3100

24-48 V DC, 10 (0.05 s n 24-240 V AC - 300 h)

2 c/o CT-AHS.22S 1SVR730110R3300 CT-AHS.22P 1SVR740110R3300

OFFdelay2)

24-240 V AC/DC

7 (0.05 s - 10 min)

1 c/o CT-ARS.11S 1SVR730120R3100 CT-ARS.11P 1SVR740120R3100

-

2 c/o CT-ARS.21S 1SVR730120R3300

CT-ARS.21P 1SVR740120R3300

Stardelta changeover3)

24-48 V DC, 24-240 V AC

7 (0.05 s - 10 min)

380-440 V AC

2 n/o CT-SDS.22S 1SVR730210R3300 CT-SDS.22P 1SVR740210R3300 CT-SDS.23S 1SVR730211R2300

CT-SDS.23P 1SVR740211R2300

1) Extended temperature range -40 °C 2) Without auxiliary voltage 3) 50 ms transition time
S: Screw connection P: Push-in / easy connect

Weight (1 pc)
kg (lb)
0.13 (0.287)
0.121 (0.267)
0.121 (0.267)
0.113 (0.249)
0.106 (0.234)
0.101 (0.222)
0.146 (0.322)
0.125 (0.276)
0.138 (0.304)
0.127 (0.28)
0.109 (0.24)
0.103 (0.227)
0.136 (0.30)
0.125 (0.276)
0.106 (0.234)
0.10 (0.22)
0.124 (0.273)
0.115 (0.254)
0.114 (0.251)
0.108 (0.238)
0.118 (0.26)
0.112 (0.247)

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

41

-- CT-S range Ordering details - Accessories

MT-x50B
30 mm adapters
Marker label 29.6 x 44.5 mm
Marker label with scale 0-10 48.5 x 44.5 mm
Sealable transparent cover for CT-S in new housing

2CDC 252 044 F0209

2CDC 252 043 F0209

2CDC 255 006 S0011

1SFC 151 139 V0001

2CDC 252 042 F0009

The CT-S range offers the possibility of using accessories such as a remote potentiometer to adjust the time delay or a sealable, transparent cover to protect against unauthorized changes of time and threshold values.

-- Remote potentiometer 50 kq ±20 % - 0.2 q, degree of protection IP66

Material
Plastic, black Plastic, chrome Metal, chrome

Diameter
in mm 22.5 22.5 22.5

Type
MT-150B MT-250B MT-350B

Order code
1SFA611410R1506 1SFA611410R2506 1SFA611410R3506

Pack.unit pieces 1
1
1

Weight 1 piece g / oz 0.040
0.040
0.048

-- 30 mm adapter for attaching the potentiometer 22 mm in 30 mm mounting hole

Material
Plastic, black Metal, chrome

Type
K A1- 8029 K A1- 8030

Order code
1SFA616920R8029 1SFA616920R8030

Pack.unit pieces
1
1

Weight 1 piece g / oz

-- Marker label
Caption
Symbol (see illustration) Scale 0 - 10 Scale 0 - 30

Type

Order code

SK 615 562-87 SK 615 562-88 MA16-1060

GJD6155620R0087 GJD6155620R0088 1SFA611940R1060

Pack.unit pieces 1
1
1

Weight 1 piece g / oz 0.002
0.002
0.002

-- Accessories for CT-S
Description

Type

Adapter for screw mounting
Sealable transparent cover
Marker label for devices w/o DIP switches Marker label for devices with DIP switches

ADP.01 COV.11 MAR.01 MAR.12

Order code
1SVR430029R0100 1SVR730005R0100 1SVR366017R0100 1SVR730006R0000

Pack.unit pieces 1
1
10
10

Weight 1 piece g / oz 0.018 (0.040)
0.004 (0.009)
0.001 (0.002)
0.001 (0.002)

42

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Technical data

Data at Ta = 25 °C and rated values, unless otherwise indicated

CT-S

Input circuit - Supply circuit

Rated control supply voltage Us

CT-xxx.x1 24-240 V AC/DC

CT-xxx.x2 24-48 V DC, 24-240 V AC

CT-xxx.x3 380-440 V AC

Rated control supply voltage US tolerance Rated frequency

-15...+10 % DC or 50/60 Hz

Frequency range AC

47-63 Hz

Typical power consumption

max. 16 VA

Power failure buffering time

24 V DC min. 15 ms

230/400 V AC min. 20 ms

Release voltage Minimum energizing time

> 10 % of the minimum rated control supply voltage Us 100 ms (CT-ARS)

Formatting time 1)

5 min (CT-ARS)

Input circuit - Control circuit

Kind of triggering

CT-MVS, CT-MXS, CT-APS voltage-related triggering

Control input, Control function

A1-Y1/B1 start timing external

Parallel load / polarized

yes / no

Maximum cable length to the control input

50 m - 100 pF/m

Minimum control pulse length

20 ms

Control voltage potential

see rated control supply voltage

Current consumption of the control input

24 V DC 1.2 mA

230 V AC 8 mA

400 V AC 6 mA

Kind of triggering

CT-MFS, CT-MBS, CT-AHS volt-free triggering

Control input, Control function

Y1-Z2 start timing external

X1-Z2 pause timing / accumulative functions (CT-MFS)

Maximum switching current in the control circuit

1 mA

Maximum cable length to the control input

50 m - 100 pF/m

Minimum control pulse length

20 ms

No-load voltage at the control inputs

10-40 V DC

Remote potentiometer

Remote potentiometer connections, resistance value

Z1-Z2 50 k (CT-MFS, CT-MBS, CT-MVS.21, CT-MXS)

Z3-Z2 50 k (CT-MXS)

Maximum cable length to remote potentiometer

2 x 25 m, shielded with 100 pF/m

Shield connection

Z2

Timing circuit

Time ranges

10 time ranges 0.05 s - 300 h 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s 4.) 1.5-30 s 5.) 5-100 s 6.) 15-300 s 7.) 1.5-30 min 8.) 15-300 min 9.) 1.5-30 h 10.) 15-300 h

7 time ranges 0.05 s - 10 min (CT-SDS, CT- 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s ARS) 4.) 1.5-30 s 5.) 5-100 s 6.) 15-300 s 7.) 0.5-10 min

Recovery time

24-240 V AC/DC < 50 ms

24-48 V DC, 24-240 V AC < 80 ms

380-440 V AC < 60 ms

Accuracy within the rated control supply voltage tolerance

it < 0.004 % / V

Accuracy within the temperature range Repeat accuracy (constant parameters) Setting accuracy of time delay

it < 0.03 % / °C < ±0.2 % ±6 % of full-scale value

Star-delta transition time Star-delta transition time tolerance

fixed 50 ms (CT-SDS, CT-MBS, CT-MFS, CT-MVS.2x) ±2 ms

1) Prior to first commisioning and after a six-month stop in operation

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

43

-- CT-S range Technical data

Indication of operational states

Control supply voltage / timing

U/T: green LED V: control supply voltage applied / W: timing

Control supply voltage

U: green LED V: control supply voltage applied

Relay state

R, R1, R2: yellow LED V: output relay energized

Output circuit

Kind of output

15-16/18 relay, 1 c/o contact

15-16/18; 25-26/28 relay, 2 c/o contacts

15-16/18; 25(21)-26(22)/28(24) relay, 2 c/o contacts, 2nd c/o contact selectable as inst. contact

17-18; 17-28 relay, 2 n/o contacts (CT-SDS)

Contact material

Cd-free, on request

Rated operational voltage Ue

IEC/EN 60947-1 250 V

Minimum switching voltage / minimum switching current

12 V / 100 mA

Maximum switching voltage / maximum switching current

see load limit curves

Rated operational current Ie

AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A

DC-12 (resistive) at 24 V 4 A

DC-13 (inductive) at 24 V 2 A (CT-ARS; 1.5 A)

AC rating (UL 508)

utilization category (Control Circuit Rating Code) B 300

max. rated operational voltage 300 V AC

maximum continuous thermal current at B300 5 A

max. making/breaking apparent power at B300 3600 VA / 360 VA

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime

at AC-12, 230 V, 4 A 0.1 x 106 switching cycles

Frequency of operation

with/without load 360/72000 h-1 CT-ARS: 1200/18000 h-1

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting

n/o contact 10 A fast-acting

General data

MTBF

on request

Duty cycle

100%

Dimensions

see `Dimensional drawings'

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

vertical / horizontal not necessary / not necessary

Material of housing

UL 94 V-0

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Screw connection technology

Easy Connect Technology (Push-in)

Connecting capacity

fine-strand with(out) wire end 1 x 0.5-2.5 mm2 (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm2 (2 x 18-16 AWG)

2 x 0.5-1.5 mm2 (2 x 18-16 AWG)

rigid 1 x 0.5-4 mm2 (1 x 20-12 AWG) 2 x 0.5-2.5 mm2 (2 x 20-14 AWG)

2 x 0.5-1.5 mm2 (2 x 20-16 AWG)

Stripping length Tightening torque

8 mm (0.32 in)

0.6-0.8 Nm (7.08 lb.in)

-

44

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Technical data

Environmental data

Ambient temperature ranges

operation / storage -25...+60 °C / -40...+85 °C, -40...+60 °C / -40...+85 °C for CT-MVS.21, CT-MFS.21, CT-ERS.21, CT-APS.21

Relative humidity range

25 % to 85 %

Vibration, sinusoidal (IEC/EN 60068-2-6)

functioning 40 m/s2, 10-58/60-150 Hz

resistance 60 m/s2, 10-58/60-150 Hz, 20 cycles

Vibration, seismic (IEC/EN 60068-3-3)

functioning 20 m/s2

Shock, half-sine (IEC/EN 60068-2-27)

functioning 150 m/s2, 11 ms, 3 shocks/direction

resistance 300 m/s2 , 11 ms, 3 shocks/direction

Isolation data

CT-S with 1 c/o

CT-S with 2 c/o

Rated insulation voltage Ui

input circuit / output circuit 500 V

output circuit 1 / output circuit 2 not available

300 V

Rated impulse withstand voltage Uimp

between all isolated circuits 4 kV; 1.2/50 µs except devices CT-xxx.23: input / output: 6 kV; 1.2/50 µs output 1 / output 2: 4 kV; 1.2/50 µs

Power-frequency withstand voltage (test voltage)

between all isolated circuits 2.0 kV; 50 Hz; 60 s

Basic insulation (IEC/EN 61140) Protective separation (IEC/EN 61140; EN 50178) Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to
electrostatic discharge radiated, radio-frequency electromagnetic field

input circuit / output circuit 500 V input circuit / output circuit 250 V
3 III
IEC/EN 61812-1 2014/35/EU 2014/30/EU 2011/65/EU
IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) 3 V/m (2 GHz) 1 V/m (2.7 GHz)

electrical fast transient / burst surge conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 Level 4, 2 kV A1-A2 IEC/EN 61000-4-6 Level 3, 10 V

harmonics and interharmonics Interference emission
high-frequency radiated high-frequency conducted

IEC/EN 61000-4-13 Class 3 IEC/EN 61000-6-3
IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

45

-- CT-S range Technical diagrams

-- DIP switch configuration CT-MXS.22x

4 3 21
ON OFF

Pulse generator, starting with ON or OFF

ON OFF

Single pulse generator, starting with OFF

ON OFF

Asymmetrical ON- and OFF-delay

ON OFF

Impulse-ON and Impulse-OFF

ON OFF

No function

ON OFF

ON/OFF function

Default setting: all DIP switches in position OFF

-- Example of application - Star-delta changeover

L1 F3

95
F2
96
S1 21 0
22

S2 13

53

I

K2

14

54

17
K1T
18

17

13

13

K2

K1

28

14

14

22
K3 21

22
K1 21

K1T N

A1

A1

A1

A1

K1

K3

K2

A2

A2

A2

A2

Y

i

N

Control circuit diagram

L1 L2 L3
135
-F1
246

135
-K2 2 4 6

135

135

-K3 2 4 6 -K1 2 4 6

154
-F2
326

97 95 98 96

-M1

W1

W2

V1

M

V2

U1 3 ~ U2

Power circuit diagram

2CDC252128F0006
2CDC 252 128 F0b06
2CDC253009F0012
2CDC 253 009 F0012

46

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Technical diagrams

2CDC252002F0b06
2CDC 252 002 F0b06
2CDC252003F0b06
2CDC 252 003 F0b06
2CDC252003F0b06
2CDC 252 003 F0b06
2CDC252004F0b06
2CDC 252 004 F0b06

-- Connection diagrams

CT-MVS.21

A1

15

Y1/B1 Z2

Y1/ B1 A1 15

25 21 Z1
25
21

CT-MVS.22

A1

15

25

Y1/B1

Y1/

B1 A1 15

25

A2 16 18 26 28
22 24

28 24 26 22

18

16

A2

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 24-240 V AC/DC

A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact 21-22/24 2nd c/o contact as
instantaneous contact

Z1-Z2

Remote potentiometer connection

A1-A2

Supply: 224-48 V DC or 24-240 V AC

A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact

CT-MVS.23

A1

15

25

Y1/B1

Y1/

B1 A1 15

25

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 380-440V AC

A1-Y1/B1 Control input

15-16/18 1st c/o contact 25-26/28 2nd c/o contact

CT-MVS.12
A1 15 Y1/B1 Y1/ B1 A1 15

A2 16 18

18

16

A2

A1-A2

Supply: 24-48 V DC or 24-240 V AC

A1-Y1/B1 Control input

15-16/18 1st c/o contact

2CDC252005F0b06
2CDC 252 005 F0b06
2CDC252006F0b06
2CDC 252 006 F0b06
2CDC252007F0b06
2CDC 252 007 F0b06
2CDC252008F0b06
2CDC 252 008 F0b06

CT-MXS.22

A1

15

25

Z3

Z2

Z1

Y1/

B1 A1 15

25

CT-MFS.21

A1 15

X1

Z2

A1

15

25 21 Z1
25
21

CT-MBS.22

A1 15 Z2

A1

15

25 21 Z1
25
21

CT-WBS.22

A1

15

25

A1

15

25

A2 16 18 26 28

28

26 Y1/B1

18

16

A2

A2 16 18

28 24 26 22

18

16

26 28
22 24
Y1 A2

A2 16 18

28 24 26 22

18

16

26 28
22 24
Y1 A2

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 24-48 V DC or 24-240 V AC

A1-Y1/B1 Control input

15-16/18 1st c/o contact

25-26/28 2nd c/o contact

Z1-Z2

Remote potentiometer connection

Z3-Z2

Remote potentiometer connection

A1-A2

Supply: 24-240 V AC/DC

15-16/18 1st c/o contact 25-26/28 2nd c/o contact 21-22/24 2nd c/o contact as
instantaneous contact

Y1-Z2 X1-Z2 Z1-Z2

Control input
Control input
Remote potentiometer connection

A1-A2

Supply: 24-48 V DC or 24-240 V AC

15-16/18 1st c/o contact

25-26/28 2nd c/o contact

21-22/24 2nd c/o contact as instantaneous contact

Y1-Z2 Control input

Z1-Z2

Remote potentiometer connection

A1-A2

Supply: 24-48 V DC or 24-240 V AC

15-16/18 1st c/o contact 25-26/28 2nd c/o contact

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

47

-- CT-S range Technical diagrams

-- Connection diagrams

A CT-ERS.21

A1

15

25

A1

15

25

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 24-240 V AC/DC

15-16/18 1st c/o contact 25-26/28 2nd c/o contact

B CT-APS.21

A1

15

25

Y1/B1

Y1/

B1 A1 15

25

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 24-240 V AC/DC

A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact

B CT-ARS.11
A1 15

A1

15

A2 16 18

18

16

A2

A1-A2

Supply: 24-240 V AC/DC

15-16/18 1st c/o contact

2CDC252014F0b06
2CDC 252 014 F0b06
2CDC252015F0b06
2CDC 252 015 F0b06

2CDC252011F0b06
2CDC 252 011 F0b06

2CDC252002F0b06
2CDC 252 009 F0b06

2CDC252010F0b06
2CDC 252 010 F0b06

2CDC252009F0b06
2CDC 252 009 F0b06

A CT-ERS.22

A1

15

25

A1

15

25

A CT-ERS.12

A1

15

A1

15

A2 16 18 26 28

28

26

18

16

A2

A2 16 18

18

16

A2

A1-A2

Supply: 24-48 V DC or 24-240 V AC

15-16/18 1st c/o contact 25-26/28 2nd c/o contact

A1-A2

Supply: 24-48 V DC or 24-240 V AC

15-16/18 1st c/o contact

2CDC252013F0b06
2CDC 252 013 F0b06

2CDC252012F0b06
2CDC 252 012 F0b06

2CDC252011F0b06
2CDC 252 011 F0b06

B CT-APS.22

A1

15

25

Y1/B1

Y1/

B1 A1 15

25

B CT-APS.12

A1 15 Y1/B1

Y1/

B1 A1

15

B CT-AHS.22

A1

15

25

Z2

A1

15

25

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 24-48 V DC or 24-240 V AC

A1-Y1/B1 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact

A2 16 18

18

16

A2

A1-A2

Supply: 24-48 V DC or 24-240 V AC

A1-Y1/B1 Control input 15-16/18 1st c/o contact

A2 16 18 26 28

28

26

Y1

18

16

A2

A1-A2

Supply: 24-48 V DC or 24-240 V AC

Y1-Z2 Control input 15-16/18 1st c/o contact 25-26/28 2nd c/o contact

B CT-ARS.21

A1

15

25

A1

15

25

A2 16 18 26 28

28

26

18

16

A2

A1-A2

Supply: 24-240 V AC/DC

15-16/18 1st c/o contact

25-26/28 2nd c/o contact

2CDC252016F0b06
2CDC 252 016 F0b06

2CDC252016F0b06
2CDC 252 016 F0b06

F CT-SDS.22

A1

17

A1

17

F CT-SDS.23

A1

17

A1

17

A2 18 28

18

28

A2

A1-A2
17-18 17-28

Supply: 24-48 V DC or 24-240 V AC
1st n/o contact 2nd n/o contact

A2 18 28

18

28

A2

A1-A2 17-18 17-28

Supply: 380-440 V AC 1st n/o contact 2nd n/o contact

2CDC252193F0205 2CDC 252 193 F0205

48

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-S range Technical diagrams

-- Load limit curves

AC load (resistive)
V 300 V 200

100 80 60 50 40 30
20

10 0.1 0.2

0.5 1

2 4 6 10

I

A

Derating factor F

-- Derating factor F for inductive AC load
1.0 0.9 0.8 0.7 0.6 0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 

2CDC252124F0206
2CDC 252 124 F0206

2CDC252194F0205 2CDC 252 194 F0205

DC load (resistive)
V 300 U 200

100 80 60 50 40 30
20

10 0,1 0,2

0,5 1

2 4 6 10

I

A

-- Contact lifetime

Switching cycles

250 V resistive load
Switching current [A]

2CDC 252 148 F0206

2CDC252148F0206

-- Wiring notes
Control inputs (volt-free triggering)

L(+)

A1

X1 Y1

A2

Z2

N(-)

2CDC 252 101 F0b06

Triggering of the control inputs (volt-free) with a proximity switch (3 wire)

L(+)

+V

A1

Y1

2CDC 252 105 F0b06

A2

Z2

N(-)

0 V

2CDC252105F0b06

2CDC252101F0b06

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

49

-- CT-S range Technical diagrams

2CDC 252 104 F0b06

2CDC252104F0b06

-- Wiring notes Control inputs (voltage-related triggering)
L(+)

A1

Y1/B1

L(+)

L(+)

A1

Y1/B1

Remote potentiometer

L(+) A1

Z3 Z1

2CDC 252 103 F0b06

2CDC 252 102 F0b06

2CDC252103F0b06

2CDC252102F0b06

A2

A2

A2

Z2

N(-)

N(-)

L(-)

N(-)

The control input Y1/B1 is triggered with electric potential against A2. It is possible to use the control supply voltage from terminal A1 or any other voltage within the rated control supply voltage range.

-- Dimensional drawings in mm and inches
113.4 4.47" 105.9 4.17"

22.5 0.89"

85.6 3.37"

2CDC25008F0010

2CDC252009F0011

68 2.68" 2CDC252010F0011
8 0.315"
2CDC252186F0005

Main device

103.7 4.08"

22.5 0.89"

8 0.32" 4.8 0.19"

front to back 110.5 4.31"
COV.11 sealable transparent cover

ADP.01 adapter for screw mounting
3A11
20 0.787"
MAR.01 marker label

50

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

51

-- Time relays for building applications Table of contents

53

Applications

54

CT-D range

54

Benefits and advantages

56

Selection table

57

Ordering details

58

Technical data

62

Technical diagrams

52

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

53

-- Time relays for building applications Applications

The CT-D range is designed in a modular housing, making it well suited for building and residential applications. In just 12 order codes the CT-D range covers all the main timing functions needed for building automation, safely and reliably.

A typical application for timers is delayed switching. Switching several rows of lamps on and off in corridors, stairwells, staircases, etc, is a widespread application in which the excellent functionality of the CT-D timers is undisputed.

Air conditioning systems, heaters and fans can be found everywhere in buildings - just like the CT-D timers long used to switch them. On-delay, off-delay and a range of other functions cover all requirements.

Elevators, escalators, gates, compressors and doors - here too ABB timers ensure optimum and time-delayed opening as required. ABB s CT-D timers cover most functions with just 12 order codes.

54

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-D range Benefits and advantages

The CT-D range is ideal for building applications and installation panels, due to its compact modular housing. For maximum flexibility in operation, nine single-function as well as two multifunction devices with seven timing functions are available. The devices offer four or seven time ranges from 0.05 seconds up to 100 hours. Their wide supply voltage range allows their use in applications worldwide.

Space savings

The CT-D range is ideal for installation panels thanks to its compact modular housing. The housing's design helps make the status and configuration more clearly visible. The CT-D range also offers a higher output current than standard industrial types. As well as the 1 c/o contacts, ABB offers devices with 2 c/o contacts for maximum flexibility.

Easy to install

Direct reading scales help make time setting quick and easy. A pre-selection for the time range together with an additional scale for fine adjustments help improve installation efficiency. For more flexibility, the delay time can even be changed when processes are running, making optimization to fit the application even simpler. All devices can be mounted and demounted tool-free.

Global availabilty

The CT-D range fulfills various global standards and approvals, supporting business worldwide. Additionally, all devices from the CT-D range have a wide supply voltage from 24-48 V DC and 24-240 V AC, making it ideal for the use in installation panels around the world.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

55

-- CT-D range Operating controls

Connection terminals Wide terminal spacing makes connection of wires simpler: 2 x 1.5 mm² (2 x 16 AWG) with wire end ferrules or 2 x 2.5 mm² (2 x 14 AWG) without ferrules.

Width 17.5 mm With a width of just 17.5 mm, the CT-D range timers are ideally suited for installation in distribution panels.

Preselection of the time range
Direct reading scales Direct setting of the time delay without any additional calculation provides accurate time delay adjustment.
Selection of the timing function A ON-delay B OFF-delay with
aux. voltage CA Impulse-ON CB Impulse-OFF with
aux. voltage DA Flasher starting
with ON DB Flasher starting
with OFF H Pulse former

Fine adjustment of the time delay
LEDs for status indication All actual operational states are displayed by front-facing LEDs, thus simplifying commissioning and troubleshooting. · U - green LED:
V control supply voltage applied / W timing · R, R1, R2 - yellow LED: V output relay energized

56

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-D range Selection table

Order number 1SVR500020R0000 1SVR500020R1100 1SVR500100R0000 1SVR500100R0100 1SVR500110R0000 1SVR500110R0100 1SVR500130R0000 1SVR500150R0000 1SVR500160R0000 1SVR500160R0100 1SVR500210R0100 1SVR500211R0100

Type CT-MFD.12 CT-MFD.21 CT-ERD.12 CT-ERD.22 CT-AHD.12 CT-AHD.22 CT-VWD.12 CT-EBD.12 CT-TGD.12 CT-TGD.22 CT-SAD.22 CT-SDD.22

Timing function

ON-delay

AJJJJ

OFF-delay with aux. voltage

BJJ

JJ

Impulse-ON

CA J J

J

Impulse-OFF with aux. voltage

CB J J

Flasher starting with ON

DA J J

J

Flasher starting with OFF

DB J J

Pulse generator starting with ON or OFF ED

JJ

Pulse former

HJJ

Star-delta change-over

F

JJ

Features Control input, voltage-related triggering

JJ

JJ

JJ

Time range 0.05 s - 100 h 0.05 s - 10 min

JJJJJJJJ2 2 JJ

Supply voltage 12-240 V AC/DC 24-48 V DC 24-240 V AC

J J JJJJJJJJJJ J JJJJJJJJJJ

Output

c/o contact

1212121112

n/o contact

22

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

57

-- CT-D range Ordering details

Description The CT-D range with its modular design is a perfect solution for installation panels. For maximum flexibility in operation, 10 single-function as well as two multifunction devices with seven timing functions are available. The devices offer four or seven time ranges from 0.05 seconds up to 100 hours. Their wide input range allows their use in applications worldwide.

2CDC251002V0018

CT-MFD.12
CT-ERD.22 M Control input with
voltage-related triggering - No triggering

2CDC251002V0018

-- Ordering details

Timing function

Rated control Time

supply

ranges

voltage

Control Output Type input

Order code

Multi1)

24-240 V AC 7 (0.05 s - M 24-48 V DC 100 h)

Multi1)

12-240 V AC/DC

7 (0.05 s - M 100 h)

ON-delay 24-240 V AC 7 (0.05 s - 24-48 V DC 100 h)

-

1 c/o CT-MFD.12 1SVR500020R0000 2 c/o CT-MFD.21 1SVR500020R1100 1 c/o CT-ERD.12 1SVR500100R0000 2 c/o CT-ERD.22 1SVR500100R0100

OFF-delay

M

1 c/o CT-AHD.12 1SVR500110R0000

M

2 c/o CT-AHD.22 1SVR500110R0100

ImpulseON
Flasher starting with ON
Pulse generator

-
2×7 (0.05 s - M 100 h)
M

1 c/o CT-VWD.12 1SVR500130R0000 CT-EBD.12 1SVR500150R0000
CT-TGD.122) 1SVR500160R0000 2 c/o CT-TGD.222) 1SVR500160R0100

Star-delta changeover

4 (0.05 s - 10 min)
-

2 n/o CT-SDD.223) 1SVR500211R0100 CT-SAD.224) 1SVR500210R0100

1) Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former
2) ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h 3) Transition time 50 ms fixed
4) Transition time adjustable

Weight (1 pc)
kg (lb) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132) 0.065 (0.143) 0.060 (0.132)
0.060 (0.132) 0.065 (0.143) 0.065 (0.143)

58

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-D range Technical data

Data at Ta = 25 °C and rated values, unless otherwise indicated

CT-D with 1 c/o contact

CT-D with 2 c/o contacts

CT-MFD.21

Input circuit - Supply circuit

Rated control supply voltage Us

24-240 V AC / 24-48 V DC

12-240 V AC/DC

Rated control supply voltage US tolerance

-15...+10 %

Rated frequency

DC or 50/60 Hz

Frequency range AC

47-63 Hz

Typical power consumption

max. 3.5 VA

Power failure buffering time

min. 20 ms

Release voltage

> 10 % of the minimum rated control supply voltage Us

Input circuit - Control circuit

Control input, control function

A1-Y1/B1 start timing external

Kind of triggering

voltage-related triggering

Resistance to reverse polarity

yes

Parallel load / polarized

yes / yes

Maximum cable length to the control inputs

50 m  100 pF/m

Minimum control pulse length

20 ms

Control voltage potential

see rated control supply voltage

Current consumption of the control input

see data sheet

Timing circuit

Time ranges

7 time ranges 0.05 s - 100 h 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min 5.) 5-100 min 6.) 0.5-10 h 7.) 5-100 h

4 time ranges 0.05 s - 10 min (CT-SDD, CT-SAD) 1.) 0.05-1 s 2.) 0.5-10 s 3.) 5-100 s 4.) 0.5-10 min

Recovery time

< 50 ms

Accuracy within the rated control supply voltage tolerance

it < 0.005 % / V

Accuracy within the temperature range Repeat accuracy (constant parameters) Setting accuracy of time delay Star-delta transition time

it < 0.06 % / °C it < ± 0.5 % ± 10% of full-scale value CT-SDD/ CT-SAD fixed 50 ms / adjustable: 20 ms, 30 ms, 40 ms, 50 ms, 60 ms, 80 ms or 100 ms

Star-delta transition time tolerance Indication of operational states Control supply voltage / timing

CT-SDD / CT-SAD ±3 ms
U: green LED V: control supply voltage applied W: timing

Relay energized

R, R1, R2: yellow LED V: output relay energized

Operating elements and controls Adjustment of the time range Fine adjustment of the time value Preselection of the timing function at multifunction devices Adjustment of the transition time

front-face rotary switch, direct reading scales front-face potentiometer front-face rotary switch, direct reading scales CT-SAC front-face potentiometer

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

59

-- CT-D range Technical data

CT-D with 1 c/o contact

CT-D with 2 c/o contacts

CT-MFD.21

Output circuit

Kind of output

15-16/18 Relay, 1 c/o contact -

15-16/18; 25-26/28 -

Relay, 2 c/o contacts

17-18; 17-28

Relay, 2 n/o contacts (CT-SDC, CT-SAC)

Contact material

AgNi alloy, Cd free

Rated operational voltage Ue

250 V

Minimum switching voltage / minimum switching current

12 V / 100 mA

Maximum switching voltage / maximum switching current

250 V AC / 6 A

250 V AC / 5 A

Rated operational current Ie

AC-12 (resistive) at 230 V 6 A

5 A

AC-15 (inductive) at 230 V 3 A

3 A

n/o: 3 A n/c: 0.75 A

DC-12 (resistive) at 24 V 6 A

5 A

DC-13 (inductive) at 24 V 2 A

2 A

1 A

AC rating (UL 508)

utilization category (Control Circuit Rating Code) B 300

n/o: B 300 n/c: C 300

max. rated operational voltage 300 V AC

maximum continuous thermal current at B300 5 A

n/o: 5 A

maximum continuous thermal current at C300 -

n/c: 2.5 A

max. making/breaking apparent power at B300 3600 VA / 360 VA

n/o: 3600/360 VA

max. making/breaking apparent power at C300 -

n/c: 1800/180 VA

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

6 A fast-acting

General data

Mean time between failures (MTBF)

on request

Duty cycle

100%

Dimensions

see `Dimensional drawings'

Mounting

DIN rail (IEC/EN 60715), snap-mounting without any tool

Mounting position

any

Minimum distance to other units

horizontal / vertical no / no

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Connecting capacity

fine-stranded with(out) 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) wire and ferrule 1 x 0.5-2.5 mm2 (1 x 20-14 AWG)

rigid 2 x 0.5-1.5 mm2 (2 x 20-16 AWG) 1 x 0.5-4 mm2 (1 x 20-12 AWG)

Stripping length

7 mm (0.28 in)

Tightening torque

0.5-0.8 Nm (4.43-7.08 lb.in)

Environmental data

Ambient temperature range

operation / storage -20 ... +60 °C / -40 ... +85 °C

Climatic class

EC/EN 60068-2-30 3K3

Relative humidity range

25-85%

Vibration, sinusoidal

IEC/EN 60068-2-6 20 m/s²; 10 cycles, 10...150...10 Hz

Shock (half-sine)

IEC/EN 60068-2-27 150 m/s2, 11 ms

60

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-D range Technical data

CT-D with 1 c/o contact

Isolation data Rated insulation voltage Ui
Rated impulse withstand voltage Uimp Power-frequency withstand voltage test(test voltage)

input circuit / output circuit 300 V output circuit 1 / output circuit 2 not available
between all isolated circuits 4 kV; 1.2/50 µs between all isolated circuits 2.5 kV; 50 Hz; 60 s

Basic insulation (IEC/EN 61140)

input circuit / output circuit 300 V

Protective separation (IEC/EN 61140, EN 50178)

input circuit / output circuit 250 V

Pollution degree

3

Overvoltage category

III

Standards / Directives

Standards

IEC/EN 61812-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3 (10 V / m)

electrical fast transient / burst

IEC/EN 61000-4-4 Level 3 (2 kV / 5 kHz)

surge

IEC/EN 61000-4-5 Level 4 (2 kV L-L)

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 Level 3 (10 V)

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

CT-D with 2 c/o contacts
300 V

CT-MFC.21 300 V

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

61

-- CT-D range Technical diagrams

-- Example of application - Star-delta changeover

L1 F3

95
F2
96
S1 21 0
22

S2 13

53

I

K2

14

54

17
K1T
18

17

13

13

K2

K1

28

14

14

22
K3 21

22
K1 21

K1T N

A1

A1

A1

A1

K1

K3

K2

A2

A2

A2

A2

Y

i

N

Control circuit diagram

L1 L2 L3
135
-F1
246

135
-K2 2 4 6

135

135

-K3 2 4 6 -K1 2 4 6

154
-F2
326

97 95 98 96

-M1

W1

W2

V1

M

V2

U1 3 ~ U2

Power circuit diagram

2CDC252128F0006
2CDC 252 128 F0b06
2CDC253009F0012
2CDC 253 009 F0012

62

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- CT-D range Technical diagrams

-- Connection diagrams
CT-MFD.21

A1

15

25

Y1/ B1 A1 15 25

CT-MFD.12

A1 15 Y1/ B1 A1

Y1/B1 15

A CT-ERD.22

A1

15

25

A1

15

25

A CT-ERD.12

A1

15

A1

15

2CDC252113F0b06
2CDC 252 113 F0b06
2CDC252114F0b06
2CDC 252 114 F0b06
2CDC252115F0b06
2CDC 252 115 F0b06
2CDC252177F0b05
2CDC 252 177 F0b05

A2 16 18 26 28

18

16 Y1/B1

28

26

A2

A1-A2
A1-Y1/B1 15-16/18 25-26/28

Supply: 12-240 V AC/DC Control input
1st c/o contact
2nd c/o contact

A2 16 18

18

16

A2

A1-A2
A1-Y1/B1 15-16/18

Supply: 24-48 V DC or 24-240 V AC
Control input
1st c/o contact

A2 16 18 26 28

18

16

28

26

A2

A1-A2
15-16/18 25-26/28

Supply: 24-48 V DC or 24-240 V AC
1st c/o contact
2nd c/o contact

A2

16 18

18

16

A2

A1-A2 15-16/18

Supply: 24-48 V DC or 24-240 V AC
1st c/o contact

2CDC252116F0b06
2CDC 252 116 F0b06
2CDC252117F0b06
2CDC 252 117 F0b06
2CDC252179F0b05
2CDC 252 179 F0b05

B CT-AHD.22

A1

15

25

Y1/ B1 A1 15 25

B CT-AHD.12

A1 15 Y1/ B1 A1

Y1/B1 15

CA CT-VWD.12

A1

15

A1

15

A2 16 18 26 28

18

16 Y1/B1

28

26

A2

A2 16 18

18

16

A2

A2

16 18

18

16

A2

A1-A2
A1-Y1/B1 15-16/18 25-26/28

Supply: 24-48 V DC or 24240 V AC Control input
1st c/o contact
2nd c/o contact

A1-A2
A1-Y1/B1 15-16/18

Supply: 24-48 V DC or 24240 V AC
Control input
1st c/o contact

A1-A2 15-16/18

Supply: 24-48 V DC or 24240 V AC
1st c/o contact

2CDC252118F0b06
2CDC 252 118 F0b06
2CDC252119F0b06
2CDC 252 119 F0b06
2CDC 252160F0b06
2CDC 252 160 F0b06
2CDC 252160F0b06
2CDC 252 160 F0b06

ED CT-TGD.22

A1

15

25

Y1/ B1 A1 15 25

ED CT-TGD.12

A1 15 Y1/ B1 A1

Y1/B1 15

F CT-SDD.22

A1

17

A1

17

F CT-SAD.22

A1

17

A1

17

A2 16 18 26 28

18

16 Y1/B1

28

26

A2

A1-A2
A1-Y1/B1 15-16/18 25-26/28

Supply: 24-48 V DC or 24-240 V AC Control input
1st c/o contact
2nd c/o contact

A2 16 18

18

16

A2

A2 18 28

28

18

A2

A2 18 28

28

18

A2

A1-A2
A1-Y1/B1 15-16/18

Supply: 24-48 V DC or 24240 V AC Control input
1st c/o contact

A1-A2 17-18 17-28

Supply: 24-48 V DC or 24-240 V AC
1st n/o contact (star contactor)
2nd n/o contact (delta contactor)

A1-A2 17-18 17-28

Supply: 24-48 V DC or 24-240 V AC
1st n/o contact (star contactor)
2nd n/o contact (delta contactor)

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

63

-- CT-D range Technical diagrams

2CDC252124F0206
2CDC 252 124 F0206

2CDC 252 123 F0206

-- Load limit curves AC load (resistive) CT-D.1x
resistive load

AC voltage [V]

CT-D.2x

AC current [A]

2CDC252044F0207

2CDC 252 044 F0207

DC voltage [V]

DC load (resistive) CT-D.1x
resistive load

CT-D.2x

DC current [A]

2CDC252045F0207

2CDC 252 045 F0207

Derating factor F

-- Derating factor F for inductive AC load
1.0 0.9 0.8 0.7 0.6 0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 
-- Contact lifetime

DC voltage [V]

2CDC 252 122 F0206

resistive load

resistive load

250 V resistive load

2CDC2520121F0206 2CDC 252 121 F0206 Switching cycles

AC voltage [V]

2CDC252122F0206

AC current [A]

DC current [A]

-- Wiring notes for devices with control input
A parallel load to the control input is possible
L(+)

A1

Y1/B1

-- Dimensional drawings in mm and inches

0.69" 17,5

58 2.28" 0.2"
5 43,4 1.71"

A2 N(-)

CT-D devices with 1 c/o contact or 2 n/o contacts

Switching current [A]

0.69" 17,5

58 2.28"

0.2"

5

43,4 1.71"

CT-D devices with 2 c/o contacts

2CDC252123F0206

2CDC252102F0006 2CDC 252 102 F0b06
70 2.76" 45 1.77" 2 2CCDDCC2255212311F301b0F60b06
80 3.15" 45 1.77" 2CCDDCC2522512301F3000F006b06

64

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

65

-- Timing functions

66

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- Timing functions CT-C, CT-S, CT-D

On delay functions (Delay on make) A
On-delay
Supply Output
t

This function requires a continuous control supply voltage for timing. Timing begins when a control supply voltage is applied. When the selected time delay is complete, the output relay energizes. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.

ON-delay accumulative

Supply Control input
Output
2nd instanteous contact

t t1 + t2 = t

t1

t3

t2

t3 = pause

OFF delay functions (Delay on break) B

OFF-delay with auxiliary voltage

Supply Control input

Output

t

<t

This function requires a continuous control supply voltage for timing. Timing begins when a control supply voltage is applied. When the selected time delay is complete, the output relay energizes. Timing can be paused by closing the control input. The elapsed time t1 is stored and continues from this time value when the control input is re-opened. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. If the control input is closed, the output relay energizes immediately. If the control input is opened, the time delay starts. When the selected time delay is complete, the output relay de-energizes. If control input re-closes before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when the control input re-opens. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.

OFF-delay without auxiliary voltage
Supply Output
t

The OFF-delay function without auxiliary voltage does not require a continuous control supply voltage for timing. Applying a control supply voltage energizes the output relay. If the control supply voltage is interrupted, the OFF-delay starts. When timing is complete, the output relay de-energizes. If a control supply voltage is re-applied before the time delay is complete, the time delay is reset and the output relay remains energized. A control supply voltage must be applied for the minimum energizing time (200 ms), for correct operation.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

67

-- Timing functions CT-C, CT-S, CT-D

OFF-delay with auxiliary voltage, accumulative

Supply Control input 1
Output
2nd instanteous contact
Control input 2

t= delay

t1 t3

t2

t=t1+t2 t3 = pause

Impulse-ON functions CA

Impulse-ON (interval)

Supply

Output

t

< t

Impulse-ON, accumulative

Supply Control input 1
Output
2nd instanteous contact
Control input 2

t adjusted pulse time

t1 t3

t2

t3 = pause

This function requires a continuous control supply voltage for timing. If the control input is closed, the output relay energizes immediately. If the control input is opened, the time delay starts. When the selected time delay is complete, the output relay de-energizes. If the control input closes before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when the control input reopens.
Pause timing / Accumulative OFF-delay: Timing can be paused by closing control 1. The elapsed time t1 is stored and continues from this time value when control input 1 is re-opened. This can be repeated as often as required. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. The output relay energizes immediately when the control supply voltage is applied and de-energizes after the set pulse time is complete. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. The output relay energizes immediately when the control supply voltage is applied and de-energizes after the set pulse time is complete. If control input 1 is open, timing begins when a control supply voltage is applied. Or, if control a supply voltage is already applied, opening control input 1 starts timing. When the selected pulse time is complete, the output relay de-energizes. Closing control input 1, before the pulse time is complete, de-energizes the output relay and resets the pulse time.
Pause timing / Accumulative impulse-ON: Timing can be paused by closing control input 2. The elapsed time t1 is stored and continues from this time value when control input 2 is re-opened. This can be repeated as often as required. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.

68

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- Timing functions CT-C, CT-S, CT-D

Impulse-OFF functions CB

Impulse-OFF with auxiliary voltage

Supply

Control input

Output

t

<t

Impulse-OFF without auxiliary voltage
Supply Output
t

Impulse-OFF with auxiliary voltage (Trailing edge interval) accumulative
Supply Control input 1
Output t
2nd instanteous contact
Control input 2

t1

t3

t2

t3 = pause t1 + t2 = t

Impulse-ON and Impulse-OFF functions CE

Impulse-ON and impulse-OFF

Supply

Control input

Output

t1

t2

<t1

This function requires a continuous control supply voltage for timing. The output relay energizes immediately when the control input is de-energized and the output de-energizes after the set pulse time is complete. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function does not require a continuous control supply voltage for timing. If the control supply voltage is interrupted, the output relay energizes and the OFF time starts. When timing is complete, the output relay de-energizes. If a control supply voltage is re-applied before the time delay is complete, the time delay is reset and the output relay de-energizes. A control supply voltage must be applied for the minimum energizing time (200 ms), for proper operation.
This function requires a continuous control supply voltage for timing. If a control supply voltage is applied, opening control input 1 energizes the output relay immediately and starts timing. When the selected pulse time is complete, the output relay de-energizes. Closing control input 1, before the pulse time is complete, de-energizes the output relay and resets the pulse time. Pause timing / Accumulative impulse-OFF: Timing can be paused by closing control input 2. The elapsed time t1 is stored and continues from this time value when control input 2 is re-opened. This can be repeated as often as required. If the control supply voltage is interrupted, the output relay de- energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. If a control supply voltage is applied, closing the control input energizes the output relay immediately and starts the pulse time t1. When t1 is complete, the output relay de-energizes. Re-opening the control input energizes the output relay immediately and starts the pulse time t2. When t2 is complete, the output relay de-energizes. t1 and t2 are independently adjustable. If the control input changes state before the pulse time is complete, the output relay de-energizes and the pulse time is reset. If the control input changes state again, the interrupted pulse time restarts. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

69

-- Timing functions CT-C, CT-S, CT-D

Flasher starting with ON functions DA

Flasher starting with ON

Supply Output

t

t

Flasher with reset starting with ON

Supply

Control input

Output

t

t

2nd contact instantaneous

t

t

Flasher starting with OFF functions DB

Flasher starting with OFF

Supply Output

t

t

Flasher with reset starting with OFF

Supply

Control input

Output

t

t

2nd contact instantaneous

t

t

Flasher starting with ON or OFF functions DE Flasher starting with ON or OFF

Supply

Control input

Output

t

t

2nd contact instantaneous

t

t

Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an ON time first. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an ON time first. The time delay can be reset by closing the control input. Opening the control input starts the timer pulsing again with symmetrical ON & OFF times. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an OFF time first. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
Applying a control supply voltage starts timing with symmetrical ON & OFF times. The cycle starts with an OFF time first. The time delay can be reset by closing the control input. Opening the control input starts the timer pulsing again with symmetrical ON & OFF times. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
Applying a control supply voltage starts timing with symmetrical ON / OFF times. If the control input is open while supply voltage is connected the cycle starts with an ON time first. If the control input is closed while supply voltage is connected the cycle starts with an OFF time first.

70

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

-- Timing functions CT-C, CT-S, CT-D

Pulse former H

Puls former (single shot)

Supply

Control input

Output

t

t

Single-pulse generator EC

Single-pulse generator, starting with OFF

Supply

Control input

Output

t1

t2

t1

t2

Pulse generator ED

Starting with the ON or OFF time (Recycling unequal times, ON or OFF first)

Supply

Control input

Output

t1

t2

t2

t1

Impulse with delay AC

Fixed impulse with adjustable time delay

Supply

Output

t1

t2

<t1

This function requires a continuous control supply voltage for timing. Closing the control input energizes the output relay immediately and starts timing. Operating the control input during the time delay has no effect. When the selected ON time is complete, the output relay de-energizes. After the ON time is complete, it can be restarted by closing the control input. If control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. Applying a control supply voltage while the control input is open energizes the output relay after the OFF time t1 is complete. When the following ON time t2 is complete, the output relay de-energizes. Alternatively, when a control supply voltage is already applied, the timing process can be started by opening control input. Closing the control input with a control supply voltage applied, de-energizes the output relay and re- sets the time delay. The ON & OFF times are independently adjustable.
This function requires a continuous control supply voltage for timing. Applying a control supply voltage, with closed control input, starts timing with an OFF time first. Applying a control supply voltage, with open control input, starts timing with an ON time first. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. The time delay t1 starts when a control supply voltage is applied. When t1 is complete, the output relay energizes for the fixed impulse time t2 of 500 ms. If the control supply voltage is interrupted, the time delay is re- set. The output relay does not change state.

Adjustable impulse with fixed time delay

Supply

Output

t2

t1

t2 <t1

This function requires a continuous control supply voltage for timing. As soon as the control supply voltage is applied the output relay will close after 500 ms. When t2 is complete, the output relay energizes and the selected pulse time t1 starts. When t1 is complete, the output relay de-energizes. If the control supply voltage is interrupted, the pulse time is reset and the output relay de-energizes.

ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS

71

-- Timing functions CT-C, CT-S, CT-D

ON- and OFF-delay AB

Symmetrical ON- and OFF-delay 1)

Supply Control input
Output
2nd instanteous contact

t1

t2

t1=t2

t1

<t2

Asymmetrical ON- and OFF-delay

Supply

Control input

Output

t1

t2

t1

<t2

Star-Delta changeover F FC

Supply

Output 1 Output 2

t1

t2

t1 = adjusted starting time

t2 = transition time

Further functions

ON/OFF function G

Supply Output

Time sector  300 h

Time sector = 300 h

This function requires a continuous control supply voltage for timing. Closing the control input starts the ON-delay time t1. When timing is complete, the output relay energizes. Opening the control input starts the OFF-delay time t2. When the OFF-delay t2 is complete, the output relay de-energizes. If the control input opens before the ON-delay (<t1) is complete, the time delay is reset and the output relay remains de-energized. If control input closes before the OFF-delay time (<t2) is complete, the time delay is reset and the output relay remains energized.
1) Variant with 2nd control input for pause timing is available too.
This function requires a continuous control supply voltage for timing. Closing the control input starts the ON-delay t1. When timing is complete, the output relay energizes. Opening the control input starts the OFF-delay t2. When the OFF-delay is complete, the output relay de-energizes. The ON-delay and OFF-delay are independently adjustable. If the control input opens before the ON-delay is complete (<t1), the time delay is reset and the output relay remains de-energized. If the control input closes before the OFF-delay is complete (<t2), the time delay is reset and the output relay remains energized. If the control supply voltage is interrupted, the output relay de-energizes and the time delay is reset.
This function requires a continuous control supply voltage for timing. Applying a control supply voltage, energizes the star contactor connected to output 1 and begins the set starting time t1. When the starting time is complete, the first output contact de-energizes the star contactor. When the transition time t2 is complete, the second output contact energizes the delta contactor. The delta contactor remains energized as long as the control supply voltage is applied. t2 is fixed to 50 ms or in some variants adjustable.
This function is used for test purposes during commissioning and troubleshooting. If the selected maximum value of the time range is smaller than 300 hours (front-face potentiometer "Time sector"  300 h), applying a control supply voltage energizes the output relay immediately. Interrupting the control supply voltage, de-energizes the output relay. If the selected maximum value of the time range is 300 hours (front- face potentiometer "Time sector" = 300 h) and a control supply voltage is applied the output relay does not energize.

72

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

73

-- Measuring and monitoring relays Table of contents

74

Benefits and advantages

76

Offer overview

79

Applications

81

Single-phase

monitoring relays

105

Three-phase

monitoring relays

137

Grid feeding

monitoring relays

151

Insulation monitoring relays

181

Thermistor motor

protection relays

203

Temperature monitoring relays

219

Liquid level monitoring relays

241

Accessories

74

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Measuring and monitoring relays Benefits and advantages

Higher utility class The plastic housing material used meets the requirements for the highest flammability class. (UL94 V-0 rated)
Snap-on housing Tool-free DIN rail installation and deinstallation of the relay.
Sealable transparent cover Protection against unauthorized changes of time and threshold values.

ERC CATALOG MEASURING AND MONITORING REL AYS

75

-- Measuring and monitoring relays Benefits and advantages

Easy Connect technology · Tool-free wiring and excellent vibration resistance. · Push-in terminals provide connection of wires up to
2 x 0.5 - 1.5 mm² (2 x 20 -16 AWG), rigid or fine-strand with or without wire end ferrules. · Excellent vibration resistance ­ the right solution for harsh environments.
Double-chamber cage connection terminals Double-chamber cage connection terminals provide connection of wires up to 2 x 0.5-2.5 mm² (2 x 20-14 AWG) rigid or fine-strand, with or without wire end ferrules.
LEDs for status indication All actual operational states are displayed by front-face LEDs, simplifying commissioning and troubleshooting.
Integrated marker label Integrated marker labels allow the product to be marked quickly and simply. No additional marker labels are required.

76

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Measuring and monitoring relays Offer overview

Measuring and monitoring relays monitor and detect operating conditions with regard to phase, current, voltage, frequency, temperature, liquid level or insulation faults. The relays inform users about abnormal conditions and allow them to take necessary corrective actions before severe and costly failures can occur. Depending on the product model, measuring and monitoring relays are categorized into seven product families.

Single-phase current monitoring relays · Monitoring of motor current consumption · Monitoring of lighting installations and heating circuits · Monitoring of transportation equipment overload · Monitoring of locking devices, electromechanical brake gear and locked rotors
Single-phase voltage monitoring relays · Speed monitoring of DC motors · Monitoring of battery voltages and other supply networks

Three-phase monitoring relays

· Voltage monitoring of mobile three-phase equipment

· Protection of personnel and installations against phase reversal

· Monitoring of the supply voltage of machines and installations

· Protection of equipment against damage caused by unstable supply voltage

v

· Switching to emergency or auxiliary supply · Protection of motors against damage caused by unbalanced phase voltages

and phase loss

· Suitable for HVAC applications

L1 L2 L3 N
V,f

Grid feeding monitoring relays The CM-UFD.M* range monitors all voltage and frequency parameters in a grid and ensures the safe feeding of decentrally produced electrical energy into the grid. · Monitoring of the voltage with up to 2 thresholds for over- and undervoltage · Monitoring of the frequency with up to 2 thresholds for over- and under-
frequency · ROCOF (rate of change of frequency) and vector shift detection · In compliance with several local standards

ERC CATALOG MEASURING AND MONITORING REL AYS

77

-- Measuring and monitoring relays Offer overview

Insulation monitoring relays · Monitoring of electrically isolated supply mains for insulation resistance failure · Detection of initial faults · Protection against earth faults

Temperature monitoring relays

Acquisition, messaging and regulation of temperatures of solid, liquid and

gaseous media in processes and machines

· Motor and system protection

· Control panel temperature monitoring



· Frost monitoring · Temperature limits for process variables, e.g. in the packing or electroplating

industry

· Control of systems and machines like heating, air-conditioning and ventilation

systems, solar collectors, heat pumps or hot water supply systems

· Bearing, gear oil and coolant monitoring

Thermistor motor protection CM-MSE and CM-MSS provide full protection of motors with integrated PTC resistor sensors.
Protection of motors against thermal overload, e. g. caused by insufficient cooling, heavy load starting conditions, undersized motors, etc.


Liquid level monitoring relays · Protection of pumps against dry running · Protection against container overflow · Control of liquid levels · Detection of leaks · Control of mixing ratios

78

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Measuring and monitoring relays Offer overview

CM-N range: Multifunctional range · 45 mm wide housing · Output contacts: 2 c/o (SPDT) contacts · Continuous voltage range (24-240 V AC/DC) or single-supply · Setting and operation via front-face operating controls · Adjustment of threshold values and switching hysteresis via direct reading scale · Adjustable time delays · Integrated and snap-fitted front-face marker label · Sealable transparent cover (accessory)

CM-S range: Universal and multifunctional range · Only 22.5 mm wide housing · Output contacts: 1 or 2 c/o (SPDT) contacts · One supply voltage range or supplied by measuring circuit · Setting and operation via front-face operating controls · Adjustment of threshold values and switching hysteresis via direct reading scale · Integrated and snap-fitted front-face marker · Snap-on housing: The relays can be placed on a DIN rail tool-free - just snap it on
or remove it tool-free · Sealable transparent cover (accessory)
CM-E range: Economy range · Only 22.5 mm wide housing · Output contacts: 1 c/o contact or 1 n/o contact · One supply voltage range · One monitoring function · Cost-efficient solution for OEM applications · Preset monitoring ranges

ERC CATALOG MEASURING AND MONITORING REL AYS

79

-- Measuring and monitoring relays Applications

ABB offers a wide selection of measuring and monitoring relays to suit a wide range of applications for businesses worldwide. Excellent vibration resistance with the Easy Connect terminal technology and railway certifications for selected products ensure the operability, even in harsh environments.

Automation panels · Textile industry - measuring and monitoring of motor
voltage and current overload of, for example, looms. · Packaging industry - measuring and monitoring of motor
voltage and current overload of, for example, conveyor belts.

Infrastructure · Water and wastewater applications - monitoring the liquid
level of water tanks and wastewater recycling plants. · Lifts - status monitoring of the three phase mains of, for
example, construction lifts, passenger lifts and escalators. · Hoisting applications - construction cranes, harbor cranes. · Railway.

Renewable energy
· Solar - monitoring of the insulation resistance and the frequency and voltage of the public grid to keep electrical grids stable and meet local requirements.
· Wind - temperature, current and voltage supervision of automation panels and electrical motors.

Buildings · Lifts - status monitoring of the three phase mains of, for
example, construction lifts, passenger lifts and escalators. · HVAC - monitoring of grid parameters, control and
protection of loads.

80

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

81

-- Single-phase monitoring relays Table of contents

82

Benefits and advantages

84

Operating controls

86

Single-phase current

monitoring relays

86

Selection table

87

Ordering details

88

Single-phase voltage

monitoring relays

88

Selection table

89

Ordering details

90

Technical data

96

Technical diagrams

98

Function diagrams

82

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase monitoring relays Benefits and advantages

For the monitoring of currents and voltages in single-phase AC/DC systems, ABB's CM-range contains a wide selection of powerful and compact devices, all in an only 22.5 mm wide housing. This product range includes current and voltage monitoring relays for over- and undercurrent and voltage protection ­ from 3 mA to 15 A, and from 3 V to 600 V.

Continuous operation

Read the status of the relay at a glance: clear visualization of the device status via LEDs. Easy to adjust with rotary wheels and variants with push-in terminals make a quick and easy installation and setting possible.

Reliable in harsh conditions

All relays work reliably in environments with low temperatures down to -25 °C. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable, no matter the environment temperature, but is also durable to shock and vibration. Save time as retightening is no longer needed, and enhance the reliability and safety of the equipment.

Easy installation

Like all devices from the measuring and monitoring portfolio, the single-phase monitoring relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. For further configuration options, additional settings can be made via dip-switches, offering the flexibility to configure, for example, the working principle of the relays and the output configuration. The device can be set up before installation in the application and easy adjustments during the process are possible.

ERC CATALOG MEASURING AND MONITORING REL AYS

83

-- Single-phase monitoring relays Benefits and advantages

Characteristics current and voltage monitoring relays1) · Monitoring of DC and AC currents: 3 mA to 15 A · Monitoring of DC and AC voltages from 3-600 V · TRMS measuring principle · One device includes 3 current measuring ranges · One device includes 4 voltage measuring ranges:
3-30 V; 6-60 V; 30-300 V; 60-600 V · Over- and undercurrent monitoring · Over- and undervoltage monitoring · ON or OFF-delay configurable · Open- or closed-circuit principle configurable · Threshold values for >U and/or <U adjustable · Latching function configurable

· Thresholds for >I and/or <I adjustable · Fixed hysteresis of 5 % · Start-up delay Tv adjustable 0; 0.1-30 s · Tripping delay Tv adjustable 0; 0.1-30 s · 1 x 2 c/o contacts (common signal) or 2 x 1 c/o contact
(separate signals for >I and <I) configurable · 1 x 2 c/o contacts (common signal) or 2 x 1 c/o contact
(separate signals for >U and <U) configurable · 22.5 mm width · 3 LEDs for the indication of operational states · Various approvals and marks
1) depending on device

Applications · Protection of electronic or electromechanical devices
against over- and under voltage or over- and under current · DC motor speed control

· Battery monitoring · Monitoring of AC or DC supplies · Monitoring of heating or lighting circuits

Current monitoring, single-phase The ABB current monitoring relays CM-SRS.xx reliably monitor the occurrence of currents that exceed or fall below the selected threshold value. The functions overcurrent or undercurrent monitoring can be preselected. Single- and multifunction devices for the monitoring of direct or alternating currents from 3 mA to 15 A are available.
Current window monitoring (Imin, Imax) The window monitoring relay CM-SFS.2x is available if the application requires the simultaneous monitoring of overand undercurrents.

Voltage monitoring, single-phase The ABB voltage monitoring relays CM-SRS.xx are used to monitor direct and alternating voltages within a range of 3-600 V. Over- or undervoltage detection can be preselected.
Voltage window monitoring (Umin, Umax) For the simultaneous detection of over- and undervoltages, the window monitoring relay CM-EFS.2 can be used.

84

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase monitoring relays Operating controls

-- Current monitoring relays

Adjustment of the threshold value >I for overcurrent
Adjustment of the tripping delay TV
DIP switches A ON-delay B OFF-delay g Closed-circuit principle h Open-circuit principle f Latching function activated e Latching function not activated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts

Adjustment of the threshold value <I for undercurrent
Indication of operational states I: red LED ­ over- / undercurrent R: yellow LED ­ relay status U/T: green LED ­ control supply voltage/timing
Adjustment of the start-up delay TS

ERC CATALOG MEASURING AND MONITORING REL AYS
-- Single-phase monitoring relays Operating controls
-- Voltage monitoring relays
Adjustment of the threshold value >U for overvoltage
Adjustment of the tripping delay TV
DIP switches A ON-delay B OFF-delay g Closed-circuit principle h Open-circuit principle f Latching function activated e Latching function not activated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts

85
Adjustment of the threshold value <U for undervoltage
Indication of operational states U: red LED ­ over- / undervoltage R: yellow LED ­ relay status U/T: green LED ­ control supply voltage/timing
Adjustment of the measuring range

86

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase current monitoring relays Selection table

CM-SFS.22S 1SVR730760R0500

CM-SFS.21P 1SVR740760R0400

CM-SFS.21S 1SVR730760R0400

CM-SRS.M2S 1SVR730840R0700

CM-SRS.M1P 1SVR740840R0600

CM-SRS.M1S 1SVR730840R0600

CM-SRS.22S 1SVR730841R1500

CM-SRS.22S 1SVR730841R0500

CM-SRS.22S 1SVR730840R0500

CM-SRS.21P 1SVR740841R1400

CM-SRS.21S 1SVR730841R1400

CM-SRS.21P 1SVR740841R0400

CM-SRS.21S 1SVR730841R0400

CM-SRS.21P 1SVR740840R0400

CM-SRS.21S 1SVR730840R0400

CM-SRS.12S 1SVR730841R1300

CM-SRS.12S 1SVR730841R0300

CM-SRS.12S 1SVR730840R0300

CM-SRS.11P 1SVR740841R1200

CM-SRS.11S 1SVR730841R1200

CM-SRS.11P 1SVR740841R0200

CM-SRS.11S 1SVR730841R0200

CM-SRS.11P 1SVR740840R0200

CM-SRS.11S 1SVR730840R0200

Order number

Type

Rated control supply voltage Us 24 - 240 V AC/DC 110 - 130 V AC 220 - 240 V AC Measuring ranges AC/DC 3 - 30 mA 10 - 100 mA 0.1 - 1 A 0.3 - 1.5 A 1 - 5 A 3 - 15 A Monitoring function Over- or undercurrent Window current monitoring Latching Open-circuit or closed-circuit principle Timing functions for tripping delay ON-delay, 0.1 - 30 s ON- or OFF-delay, 0.1 - 30 s Output c/o contact Connection type Push-in terminals Double-chamber cage connection terminals
adj: adjustable sel: selectable

JJ

J

JJ

J

JJJJJJ

JJ

J

JJ

J

JJ

J

JJ

J

JJJJJJ

JJJJJJ

JJ JJ

JJJJJJ

JJJJJJ

JJ JJ

JJJJJJ

JJJJJJ

JJ JJ

JJJ

JJJ

J

J

JJJ

JJJ

J

J

JJJ

JJJ

J

J

JJJJJJJJJJJJJJJJJJJJJ JJJ
sel sel sel sel sel sel
sel sel sel sel sel sel

adj adj adj adj adj adj adj adj adj adj adj adj sel sel sel

111111111222222222222222

JJJ

JJJ

J

J

J J J JJJJ J J JJJJ JJ J

ERC CATALOG MEASURING AND MONITORING REL AYS

87

-- Single-phase current monitoring relays Ordering details

CM-SRS.22S CM-SFS.22P

2CDC 251 056 V0011

2CDC 251 054 V0011

Description The CM range current monitoring relays protect single-phase mains (DC or AC) from over- and undercurrent from 3 mA to 15 A.

-- Ordering details

Description

Type

See selection table

CM-SRS.11S

CM-SRS.11P

CM-SRS.12S

CM-SRS.21S

CM-SRS.21P

CM-SRS.22S

S: screw connection P: push-in connection

CM-SRS.M1S CM-SRS.M1P CM-SRS.M2S CM-SFS.21S CM-SFS.21P CM-SFS.22S

Order code
1SVR730840R0200 1SVR730841R0200 1SVR730841R1200 1SVR740840R0200 1SVR740841R0200 1SVR740841R1200 1SVR730840R0300 1SVR730841R0300 1SVR730841R1300 1SVR730840R0400 1SVR730841R0400 1SVR730841R1400 1SVR740840R0400 1SVR740841R0400 1SVR740841R1400 1SVR730840R0500 1SVR730841R0500 1SVR730841R1500 1SVR730840R0600 1SVR740840R0600 1SVR730840R0700 1SVR730760R0400 1SVR740760R0400 1SVR730760R0500

Weight (1 pc) kg (lb) 0.145 (0.320) 0.161 (0.355) 0.161 (0.355) 0.137 (0.302) 0.153 (0.337) 0.153 (0.337) 0.137 (0.302) 0.168 (0.370) 0.168 (0.370) 0.152 (0.335) 0.179 (0.395) 0.179 (0.395) 0.141 (0.311) 0.168 (0.370) 0.168 (0.370) 0.144 (0.399) 0.181 (0.399) 0.181 (0.399) 0.153 (0.337) 0.142 (0.313) 0.155 (0.342) 0.150 (0.331) 0.139 (0.306) 0.158 (0.348)

88

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase voltage monitoring relays Selection table

CM-EFS.2P 1SVR740750R0400

CM-EFS.2S 1SVR730750R0400

CM-ESS.MP 1SVR740830R0500

CM-ESS.MS 1SVR730830R0500

CM-ESS.2P 1SVR740831R1400

CM-ESS.2S 1SVR730831R1400

CM-ESS.2P 1SVR740831R0400

CM-ESS.2S 1SVR730831R0400

CM-ESS.2P 1SVR740830R0400

CM-ESS.2S 1SVR730830R0400

CM-ESS.1P 1SVR740831R1300

CM-ESS.1S 1SVR730831R1300

CM-ESS.1P 1SVR740831R0300

CM-ESS.1S 1SVR730831R0300

CM-ESS.1P 1SVR740830R0300

CM-ESS.1S 1SVR730830R0300

Order number

Type

Rated control supply voltage Us 24 - 240 V AC/DC 110 - 130 V AC 220 - 240 V AC Measuring ranges AC/DC 3 - 30 V 6 - 60 V 30 - 300 V 60 - 600 V Monitoring function Over- or undervoltage Windows voltage monitoring Latching Open-circuit or closed-circuit principle Timing functions for tripping delay ON-delay, 0.1 - 30 s ON- or OFF-delay, 0.1 - 30 s Output c/o contact Connection type Push-in terminals Double-chamber cage connection terminals
adj: adjustable sel: selectable

JJ

JJ

JJJJ

JJ

JJ

JJ

JJ

JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJ

JJJJJJJJJJJJJJ JJ
sel sel sel sel
sel sel sel sel

adj adj adj adj adj adj adj adj sel sel

1111112222222222

JJJJJJJJ JJJJJJJJ

ERC CATALOG MEASURING AND MONITORING REL AYS

89

-- Single-phase voltage monitoring relays Ordering details

CM-ESS.MP CM-EFS.2

2CDC 251 059 V0011

2CDC 251 060 V0011

Description The CM range voltage monitoring relays provide reliable monitoring of voltages, as well as the detection of phase loss in single-phase mains.

-- Ordering details

Description

Type

See selection table

CM-ESS.1S

CM-ESS.1P

CM-ESS.2S

CM-ESS.2P

S: screw connection P: push-in connection

CM-ESS.MS CM-ESS.MP CM-EFS.2S CM-EFS.2P

Order code
1SVR730830R0300 1SVR730831R0300 1SVR730831R1300 1SVR740830R0300 1SVR740831R0300 1SVR740831R1300 1SVR730830R0400 1SVR730831R0400 1SVR730831R1400 1SVR740830R0400 1SVR740831R0400 1SVR740831R1400 1SVR730830R0500 1SVR740830R0500 1SVR730750R0400 1SVR740750R0400

Weight (1 pc) kg (lb) 0.135 (0.298) 0.164 (0.362) 0.164 (0.362) 0.126 (0.278) 0.155 (0.342) 0.155 (0.342) 0.153 (0.337) 0.181 (0.399) 0.181 (0.399) 0.142 (0.313) 0.170 (0.375) 0.170 (0.375) 0.154 (0.340) 0.143 (0.320) 0.157 (0.346) 0.146 (0.322)

90

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase current monitoring relays Technical data

Type

CM-SRS.1

CM-SRS.2

CM-SRS.M

CM-SFS.2

Input circuit - Supply circuit

A1-A2

Rated control supply voltage Us

A1-A2 110-130 V AC A1-A2 220-240 V AC

A1-A2 24-240 V AC/DC

Rated control supply voltage Us tolerance

-15...+10 %

Rated frequency

AC versions 50/60 Hz

AC/DC versions 50/60 Hz or DC

Current / power consumption

see data sheets

Power failure buffering time

20 ms

Transient overvoltage protection

Varistors

Input circuit - Measuring circuit

B1/B2/B3-C

Monitoring function

over- or undercurrent monitoring configurable

over- and undercurrent monitoring

Measuring method

True RMS measuring principle

Measuring inputs

CM-SxS.x1

CM-SxS.x2

Terminal connection B1-C

B2-C

B3-C

B1-C

B2-C

B3-C

Measuring ranges AC/DC 3-30 mA

10-100 mA 0.1-1 A

0.3-1.5 A

1-5 A

3-15 A1)

Input resistance 3.3 

1 

0.1 

0.05 

0.01 

0.0025 

Pulse overload 500 mA

1 A

capacity t< 1 s

10 A

15 A

50 A

100 A

Continuous capacity 50 mA

150 mA

1.5 A

2 A

7 A

17 A

Threshold value(s)

adjustable within the indicated measuring range

Setting accuracy of threshold value

10 % of full-scale value

Hysteresis related to the threshold value

3-30 % adjustable

5 % fixed

Measuring signal frequency range

DC / 15 Hz - 2 kHz

Rated measuring signal frequency range

DC / 50-60 Hz

Maximum response time

AC: 80 ms / DC: 120 ms

Accuracy within the control supply voltage tolerance

U m 0.5 %

Accuracy within the temperature range

U m 0.06 % / °C

Timing circuit

Start-up delay TS

none

0 or 0.1-30 s adjustable

Tripping delay TV

none

0 or 0.1-30 s adjustable

Repeat accuracy (constant parameters)

w0.07 % of full scale

Accuracy within the control supply voltage tolerance

-

t  0.5 %

Accuracy within the temperature range

-

t  0.06 % / °C

Indication of operational states

Control supply voltage

U/T: green LED V: control supply voltage applied, X: start-up delay TS active, W: tripping delay TV active

Measured value

I: red LED V: overcurrent, W: undercurrent

Relay status

R: yellow LED V: relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function

ERC CATALOG MEASURING AND MONITORING REL AYS

91

-- Single-phase current monitoring relays Technical data

Type

CM-SRS.1

CM-SRS.2

CM-SRS.M

CM-SFS.2

Output circuits

11(15)-12(16)/14(18), 21(25)-22(26)/24(28) - Relays

Kind of output

1 c/o contact

2 c/o contacts

1x2 c/o contacts or 2x1 c/o contact configurable

Operating principle

open-circuit principle 2)

open- or closed-circuit principle configurable2)

Contact material

AgNi

Minimum switching voltage / minimum switching current 24 V / 10 mA

Maximum switching voltage / maximum switching current 250 V AC / 4 A AC

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A

DC-13 (inductive) at 24 V 2 A

AC rating (UL 508)

Utilization category B 300 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current at B 300 5 A

max. making/breaking apparent power 3600/360 VA (Make/Break) at B 300

Mechanical lifetime

30x106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1x106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

10 A fast-acting

6 A fast-acting

(1) In case of measured currents > 10 A, lateral spacing has to be min. 10 mm (2) Open-circuit principle: output relay energizes if the measured value exceeds b / falls below a the adjusted threshold value
Closed-circuit principle: output relay de-energizes if measured value exceeds b / falls below a the adjusted threshold value

92

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase current monitoring relays Technical data

Type

CM-SRS.1

CM-SRS.2

CM-SRS.M

CM-SFS.2

General data

MTBF

on request

Duty cycle

100%

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

10 mm (0.39 in) at measured current > 10 A

Material of housing

UL 94 V-0

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Connecting capacity

Screw connection technology
fine-strand with(out) wire end 1 x 0.5-2.5 mm² (1 x 20-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm² (2 x 20-16 AWG)

rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)

2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (7.08 lb.in)

-

Environmental data

Ambient temperature range

operation / -20...+60 °C / storage -40...+85 °C

Damp heat (IEC 60068-2-30)

55 °C, 6 cycles

Vibration (sinusoidal)

class 2

Shock

class 2

Isolation data

Rated insulation voltage

supply / 600 V measuring circuit / output

supply / output 1/2 250 V

Rated impulse withstand voltage Uimp

supply /measuring 6 kV 1.2/50 s circuit / output

supply / output 1/2 4 kV 1.2/50 s

Pollution degree

3

Overvoltage category

III

Standards / Directives

Standards

IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 3

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3

electrical fast transient / burst

IEC/EN 61000-4-4 level 3

surge

IEC/EN 61000-4-5 level 3

conducted disturbances, induced by IEC/EN 61000-4-6 level 3 radio-frequency fields

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22; EN 55022 Class B

high-frequency conducted

IEC/CISPR 22; EN 55022 Class B

ERC CATALOG MEASURING AND MONITORING REL AYS

93

-- Single-phase voltage monitoring relays Technical data

Type Input circuit - Supply circuit Rated control supply voltage Us
Rated control supply voltage Us tolerance Rated frequency
Current / power consumption Power failure buffering time Transient overvoltage protection Input circuit - Measuring circuit Monitoring function

CM-ESS.1

CM-ESS.2

A1-A2

A1-A2 110-130 V AC

A1-A2 220-240 V AC

A1-A2 24-240 V AC/DC

-15...+10 %

AC versions 50/60 Hz

AC/DC versions 50/60 Hz or DC

see data sheet

20 ms

varistors

B-C

over- or undervoltage monitoring configurable

CM-ESS.M

Measuring method

True RMS measuring principle

Measuring inputs

CM-ExS

Terminal connection B-C

B-C

B-C

Measuring range AC/DC 3-30 V

6-60 V

30-300 V

Input resistance 600 kq

600 kq

600 kq

Pulse overload capacity 800 V t < 1 s

800 V

800 V

Continuous capacity 660 V

660 V

660 V

Threshold value(s)

adjustable within the indicated measuring range

Tolerance of the adjusted threshold value

10 % of full-scale value

Hysteresis related to the threshold value

3-30 % adjustable

Measuring signal frequency range

DC / 15 Hz - 2 kHz

Rated measuring signal frequency range

DC / 50-60 Hz

Maximum response time

AC: 80 ms / DC: 120 ms

Accuracy within the control supply voltage tolerance

U m 0.5 %

Accuracy within the temperature range

U m 0.06 % / °C

Transient overvoltage protection

Varistors

Timing circuit

Delay time TV

none

0 or 0.1-30 s adjustable

Repeat accuracy (constant parameters)

w0.07 % of full scale value

Accuracy within the control supply voltage tolerance

-

t m 0.5 %

Accuracy within the temperature range

-

t m 0.06 % / °C

Indication of operational states

Control supply voltage

U/T: green LED V: control supply voltage applied W: tripping delay TV active

Measured value

U: red LED V: overvoltage, W: undervoltage

Relay status

R: yellow LED V: relay energized, no latching function Z: relay energized, active latching function Y: relay de-energized, active latching function

CM-EFS.2
over- and under voltage monitoring configurable B-C 60-600 V 600 kq 800 V 660 V 5 % fixed

94

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase voltage monitoring relays Technical data

Type Output circuits Kind of output

CM-ESS.1 1 c/o contact

CM-ESS.2 2 c/o contacts

Operating principle

open-circuit principle1)

Contact material

AgNi

Minimum switching voltage / minimum switching current 24 V / 10 mA

Maximum switching voltage / maximum switching current 250 V AC / 4 A AC

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A DC-12 (resistive) at 24 V 4 A

DC-13 (inductive) at 24 V 2 A

AC rating (UL 508)

Utilization category B 300 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current at B 300 5 A

max. making/breaking apparent power 3600/360 VA (Make/Break) at B 300

Mechanical lifetime

30x106 switching cycles

Electrical lifetime

AC-12, 230 V, 4 A 0.1x106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

10 A fast-acting

CM-ESS.M

CM-EFS.2

1x2 c/o contacts or 2x1 c/o contact configurable
open- or closed-circuit principle configurable1)

6 A fast-acting

ERC CATALOG MEASURING AND MONITORING REL AYS

95

-- Single-phase voltage monitoring relays Technical data

Type

CM-ESS.1

CM-ESS.2

CM-ESS.M

CM-EFS.2

General data

MTBF

on request

Duty cycle

100%

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

vertical / horizontal not necessary / not necessary

Material of housing

UL 94 V-0

Degree of protection

housing / terminals IP50 / IP20

Environmental data

Ambient temperature ranges

operation -20...+60 °C

storage -40...+85 °C

Damp heat, cyclic (IEC/EN 60068-2-30)

55 °C, 6 cycle

Vibration, sinusoidal

class 2

Shock

class 2

Electrical connection

Wire size

Screw connection technology

Easy Connect Technology (Push-in)

fine-strand with(out) wire end ferrule 1 x 0.5-2.5 mm² (1 x 18-14 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG)

2 x 0.5-1.5 mm² (2 x 18-16 AWG)

rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)

2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (7.08 lb.in)

-

Isolation data

Rated insulation voltage

supply / measuring 600 V circuit / output

supply / output 1/2 250 V

Rated impulse withstand voltage Uimp supply / measuring 6 kV 1.2/50 s circuit / output

supply / output 1/2 4 kV 1.2/50 s

Pollution degree

3

Overvoltage category

III

Standards / Directives

Product standard

IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 3

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3

electrical fast transient / burst

IEC/EN 61000-4-4 level 3

surge

IEC/EN 61000-4-5 level 3

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22; EN 55022 class B

high-frequency conducted

IEC/CISPR 22; EN 55022 class B

1) Open-circuit principle: output relay energizes if the measured value exceeds d / falls below c the adjusted threshold value Closed-circuit principle: output relay de-energizes if measured value exceeds d / falls below c the adjusted threshold value

96

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase current monitoring relays Technical diagrams

-- Connection diagram

2CDC252205F0005
2CDC 252 205 F0005

2CDC252204F0005
2CDC 252 204 F0005

CM-SRS.1x, CM-SRS.2x

A1

1115

C

B1 B2 B3

B1 B2 B3

1115

C

CM-SRS.Mx

A1

1115

B1 B2

B1 B2 B3 1115

2125 B3
2125

C

2CDC252204F0005
2CDC 252 205 F0005

A1 A2 1216 1418

1418 1216

A2

A1

1115

B1 B2

B1 B2 B3 1115

2125 B3
2125

C

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2

Control supply voltage

B1-C

Measuring range 1: 3-30 mA or 0.3-1.5 A

B2-C

Measuring range 2: 10-100 mA or 1-5 A

B3-C

Measuring range 3: 0.1-1 A or 3-15 A

1115-1216/1418 Output contacts 2125-2226/2428 open-circuit
principle

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2

Control supply voltage

B1-C

Measuring range 1: 3-30 mA or 0.3-1.5 A

B2-C

Measuring range 2: 10-100 mA or 1-5 A

B3-C

Measuring range 3: 0.1-1 A or 3-15 A

1115-1216/1418 Output contacts 2125-2226/2428 open- or
closed circuit principle

2CDC252205F0005
2CDC 252 205 F0005

CM-SFS.2x

A1

1115

B1 B2

B1 B2 B3 1115

2125 B3
2125

C

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2

Control supply voltage

B1-C

Measuring range 1: 3-30 mA or 0.3-1.5 A

B2-C

Measuring range 2: 10-100 mA or 1-5 A

B3-C

Measuring range 3: 0.1-1 A or 3-15 A

1115-1216/1418 2125-2226/2428

Output contacts open- or closed circuit principle

2CDC252205F0005
2CDC 252 205 F0005

CM-SRS.2x

A1

1115

B1 B2

B1 B2 B3 1115

2125 B3
2125

C

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2

Control supply voltage

B1-C

Measuring range 1: 3-30 mA or 0.3-1.5 A

B2-C

Measuring range 2: 10-100 mA or 1-5 A

B3-C

Measuring range 3: 0.1-1 A or 3-15 A

1115-1216/1418 2125-2226/2428

Output contacts open- or closed circuit principle

-- DIP switch functions CM-SRS.1x, CM-SRS.2x
1 ON Undercurrent monitoring
OFF Overcurrent monitoring
OFF = Default

CM-SRS.Mx

Position

4

ON

3

2

1

closed I

OFF

open

I

1 ON OFF

Undercurrent monitoring Overcurrent monitoring

2 ON OFF

Closed-circuit principle Open-circuit principle

3 ON OFF

Latching function activated Latching function not activated

OFF = Default

CM-SFS.2x

Position

4

3

2

1

ON

2x1 c/o

closed

OFF

1x2 c/o

open

1 ON OFF-delay OFF ON-delay
2 ON Closed-circuit principle
OFF Open-circuit principle
3 ON Latching function activated
OFF Latching function not activated
4 ON 2x1 c/o contact OFF 1x2 c/o contacts
OFF = Default

CM-SRS.2x

Position

4

ON

3

2

1

closed I

OFF

open

I

1 ON Undercurrent monitoring
OFF Overcurrent monitoring
2 ON Closed-circuit principle OFF Open-circuit principle
3 ON Latching function activated
OFF Latching function not activated
OFF = Default

22CCDDCC252252272F7020F005005 22CCDDCC2255227237F30F0000505 22CCDDCC2522527247F40F0000505 22CCDDCC25225227327F300F005005

ERC CATALOG MEASURING AND MONITORING REL AYS

97

-- Single-phase voltage monitoring relays Technical diagrams

-- Connection diagram

2CDC252207F0005
2CDC 252 207 F0005

2CDC252206F0005
2CDC 252 206 F0005

CM-ESS.1, CM-ESS.2

A1

1115

C

B

B

1115

C

CM-EFS.2

A1

1115 2125

B

B

1115 2125

C

2CDC252207F0005
2CDC 252 207 F0005

A1 A2 1216 1418

1418 1216

A2

A1

1115 2125

B

B

1115 2125

C

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2 B-C

Control supply voltage
Measuring ranges AC/DC: 3-30 V; 6-60 V; 30-300 V; 60-600 V

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2 B-C

Control supply voltage
Measuring ranges AC/DC: 3-30 V; 6-60 V; 30-300 V; 60-600 V

1115-1216/1418 Output contacts 2125-2226/2428 open- or closed
circuit principle

1115-1216/1418 2125-2226/2428

Output contacts open-circuit principle

2CDC252207F0005
2CDC 252 207 F0005

CM-ESS.M

A1

1115 2125

B

B

1115 2125

C

A1 A2 1216 1418 2226 2428

1418 1216

C

2428 2226

A2

A1-A2 B-C
1115-1216/1418 2125-2226/2428

Control supply voltage
Measuring ranges AC/DC: 3-30 V; 6-60 V 30-300 V; 60-600 V
Output contacts open- or closed circuit principle

-- DIP switch functions CM-ESS.1, CM-ESS.2
1 ON Undervoltage monitoring
OFF Overvoltage monitoring
OFF = Default

CM-EFS.2

Position

4

3

2

1

ON

2x1 c/o

closed

OFF

1x2 c/o

open

CM-ESS.M

Position

4

ON

3

2

1

closed V

OFF

open

V

1 ON ON-delay OFF OFF-delay
2 ON Closed-circuit principle
OFF Open-circuit principle
3 ON Latching function activated
OFF Latching function not activated
4 ON 2x1 c/o contact OFF 1x2 c/o contacts
OFF = Default

1 ON OFF

Undervoltage monitoring Overvoltage monitoring

2 ON OFF

Closed-circuit principle Open-circuit principle

3 ON OFF

Latching function activated Latching function not activated

OFF = Default

2CCDDCC2522527257F500F05005 22CCDDCC2522522742F7040F005005 22CCDDCC25225227267F600F00505

98

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase monitoring relays Function diagrams

CM-SRS.1x and CM-SRS.2x
If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-SRS.1x - immediately, on the CM-SRS.2x - after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s). The hysteresis is adjustable within a range of 3-30 % of the threshold value.

2CDC 252 208 F0205

CM-SRS.1x

Overcurrent monitoring b
A1-A2 Threshold Hysteresis Measured value 11-14 (15-18) 11-12 (15-16) green LED
red LED yellow LED
Undercurrent monitoring a
A1-A2 Measured value
Hysteresis Threshold 11-14 (15-18) 11-12 (15-16) green LED
red LED yellow LED

2CDC 252 209 F0205

CM-SRS.2x

Overcurrent monitoring b

A1-A2

Threshold

Hysteresis

Measured value

TV

< TV

11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Undercurrent monitoring a

A1-A2

Measured value

TV

< TV

Hysteresis

Threshold

11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED

2CDC 252 211 F0205

2CDC 252 210 F0205

Further function diagrams see data sheet.

ERC CATALOG MEASURING AND MONITORING REL AYS

99

-- Single-phase monitoring relays Function diagrams

CM-SRS.Mx
If the measured value exceeds resp. drops below the adjusted threshold value before the set start-up delay TS is complete, the output relays do not change their actual state. If the measured value exceeds resp. drops below the adjusted threshold value when TS is complete, the tripping delay TV starts. If TV is complete and the measured value is still exceeding resp. below the threshold value plus resp. minus the set hysteresis, the output relays energize h / de-energize g.
If the measured value exceeds resp. drops below the threshold value minus resp. plus the set hysteresis and the latching function is not activated e, the output relays de-energize h / energize g. With activated latching function f the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. The hysteresis is adjustable within a range of 3-30 % of the threshold value.

2CDC 252 212 F0205

Overcurrent monitoring b with latching f

A1-A2

Threshold

Hysteresis

Measured value

Open-circuit principle open

TS

11-14 (15-18) 11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Reset

TV

TS

< TV

Undercurrent monitoring b with latching f

A1-A2

Measured value Hysteresis Threshold

Open-circuit principle open

TS

11-14 (15-18)

11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Reset

TV

TS

< TV

2CDC 252 215 F0205

2CDC 252 214 F0205

Overcurrent monitoring b without latching e

A1-A2

Threshold

Hysteresis

Measured value

Open-circuit principle open

TS

TV

< TV

11-14 (15-18) 11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Undercurrent monitoring a without latching e

A1-A2

Measured value Hysteresis Threshold

Open-circuit principle open

TS

TV

11-14 (15-18)

< TV

11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

2CDC 252 213 F0205

Further function diagrams see data sheet.

100

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase monitoring relays Function diagrams

CM-SFS.2x Current window monitoring 1x2 c/o contact j ON-delayed A without latching f

A1-A2

Thresholdmax Hysteresis

Measured value

TS

TV

Hysteresis

Thresholdmin

< TV

Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED
Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED

2CDC 252 216 F0205

ON-delayed A current window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value before the set start-up delay TS is complete, the output relays do not change their actual state. If the measured value exceeds resp. drops below the adjusted threshold value when TS is complete, the tripping delay TV starts when A is configured. If TV is complete and the measured value is still exceeding resp. below the threshold value minus resp. plus the fixed hysteresis (5%), the output relays energize h /de-energize g. If the measured value exceeds resp. drops below the threshold value plus resp. minus the hysteresis and the latching function is not activated f, the output relays de-energize h / energize g. With activated latching function e the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays r emain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset.

Current window monitoring 1x2 c/o contact j OFF-delayed B without latching e

A1-A2

Thresholdmax Hysteresis

Measured value

TS

TV

TV

Hysteresis

Thresholdmin

Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED

2CDC 252 217 F0205

OFF-delayed B current window monitoring with parallel switching c/o contacts j:
If the measured value exceeds resp. drops below the adjusted threshold value when the set start-up delay TS is complete, the output relays energize h / de-energize g, when B is configured, and remain in this position during the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the fixed hysteresis (5%) and the latching function is not activated e, the tripping delay TV starts. After completion of TV, the output relays de-energize h / energize g, provided that the latching function is not activated e. With activated latching function f the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. When i is adjusted on the device, the functionality is equivalent to the one described above. In this case, instead of both output relays, only one output relay each will be switched. ">I" = 1115-1216/1418 ; "<I" = 2125-2226/2428

Further function diagrams see data sheet.

ERC CATALOG MEASURING AND MONITORING REL AYS

101

-- Single-phase monitoring relays Function diagrams

CM-ESS.1x and CM-ESS.2x
Depending on the configuration, the voltage monitoring relays CM-ESS.1 and CM-ESS.2 can be used for over- d or undervoltage monitoring c in single-phase AC and/or DC systems. The voltage to be monitored (measured value) is applied to terminals B-C. The devices work according to the open-circuit principle. If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-ESS.1 - immediately, on the CM-ESS.2 - after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s). The hysteresis is adjustable within a range of 3-30 % of the threshold value.

CM-ESS.1x CM-ESS.2x

Overvoltage monitoring d
A1-A2 Threshold Hysteresis Measured value 11-14 (15-18) 11-12 (15-16) green LED
red LED yellow LED
Undervoltage monitoring c
A1-A2 Measured value
Hysteresis Threshold 11-14 (15-18) 11-12 (15-16) green LED
red LED yellow LED

Overvoltage monitoring d

A1-A2

Threshold

Hysteresis

Measured value

TV

11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Undervoltage monitoring c

A1-A2

Measured value

TV

Hysteresis

Threshold

11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED

< TV < TV

2CDC 252 211 F0205

2CDC 252 210 F0205

2CDC 252 209 F0205

2CDC 252 208 F0205

Further function diagrams see data sheet.

102

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Single-phase monitoring relays Function diagrams

CM-ESS.Mx
If the measured value exceeds resp. drops below the adjusted threshold value, the tripping delay TV starts. If TV is complete and the measured value is still exceeding resp. below the threshold value plus resp. minus the set hysteresis, the output relays energize h / de-energize g. If the measured value exceeds resp. drops below the threshold value plus resp. minus the set hysteresis and the latching function is not activated e, the output relays de-energize h / energize g. With activated latching function f the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. The hysteresis is adjustable within a range of 3-30 % of the threshold value.

2CDC 252 230 F0205

Overvoltage monitoring d without latching e

A1-A2

Threshold

Hysteresis

Measured value

Open-circuit principle open

< TV

TV

< TV

11-14 (15-18) 11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Undervoltage monitoring c without latching e

A1-A2
Measured value Hysteresis Threshold

Open-circuit principle open

< TV

TV

11-14 (15-18)

< TV

11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

2CDC 252 229 F0205

2CDC 252 228 F0205

Overvoltage monitoring d with latching f

A1-A2 Threshold

Reset

Hysteresis

Measured value

Open-circuit principle open

< TV

TV

< TV

11-14 (15-18) 11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Undervoltage monitoring c without latching f

A1-A2
Measured value Hysteresis Threshold

Reset

Open-circuit principle open

< TV

TV

11-14 (15-18)

< TV

11-12 (15-16)

21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

Closed-circuit principle closed
11-14 (15-18) 11-12 (15-16)
21-24 (25-28) 21-22 (25-26)

green LED

red LED

yellow LED

2CDC 252 231 F0205

Further function diagrams see data sheet.

ERC CATALOG MEASURING AND MONITORING REL AYS

103

-- Single-phase monitoring relays Function diagrams

CM-EFS.2x
Voltage window monitoring 1x2 c/o contact j ON-delayed A without latching e

A1-A2

Thresholdmax Hysteresis

Measured value

< TV

TV

Hysteresis

Thresholdmin

< TV

Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED
Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED

Voltage window monitoring 1x2 c/o contact j OFF-delayed B without latching e

A1-A2

Thresholdmax Hysteresis

Measured value

TV

TV

Hysteresis

Thresholdmin

Open-circuit principle open 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED
Closed-circuit principle closed 11-14 (15-18) 11-12 (15-16) 21-24 (25-28) 21-22 (25-26)
green LED
red LED
yellow LED

2CDC 252 233 F0205

2CDC 252 232 F0205

ON-delayed A voltage window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value, the tripping delay TV starts, when A is configured. If TV is complete and the measured value is still exceeding resp. below the threshold value minus resp. plus the fixed hysteresis (5%), the output relays energize h / de-energize g. If the measured value exceeds resp. drops below the threshold value plus resp. minus the hysteresis and the latching function is not activated e, the output relays de-energize h / energize g. With activated latching function e the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset.
OFF-delayed B voltage window monitoring with parallel switching c/o contacts j: If the measured value exceeds resp. drops below the adjusted threshold value, the output relays energize h / de-energize g, when B is configured, and remain in this position during the set tripping delay TV.
If the measured value exceeds resp. drops below the threshold value plus resp. minus the fixed hysteresis (5%) and the latching function is not activated e, the tripping delay TV starts.
After completion of TV, the output relays de-energize h / energize g, provided that the latching function is not activated e. With activated latching function e the output relays remain energized h and de-energize only when the supply voltage is interrupted / the output relays remain de-energized g and energize only when the supply voltage is switched off and then again switched on = Reset. When i is adjusted on the device, the functionality is equivalent to the one described above. In this case, instead of both output relays, only one output relay each will be switched. ">U" = 1115-1216/1418 ; "<U" = 2125-2226/2428

Further function diagrams see data sheet.

104

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

105

-- Three-phase monitoring relays Table of contents

106

Benefits and advantages

109

Function

110

Operating controls

112

Selection table - singlefunctional

113

Ordering details - singlefunctional

114

Selection table - multifunctional

115

Ordering details - multifunctional

116

Technical data

127

Technical diagrams

129

Function diagrams

106

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Benefits and advantages

For the monitoring of voltages in a three-phase system or network, ABB's CM range contains a wide selection of powerful and compact devices. This product range includes voltage monitoring relays for phase sequence, phase loss, unbalance and monitoring of over- and under voltage from 160 V to 820 V.

Continuous operation

Read the status of the relay at a glance: clear visualization of the device status via LEDs. Easy to adjust with rotary wheels and variants with push-in terminals make a quick and easy installation and setting possible.

Reliable in harsh conditions

All relays work reliably in environments with low temperatures down to -25°C. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable no matter the environment temperature but is also durable to shock and vibration. Save time as retightening is no longer needed and enhance the reliability and safety not only for the equipment.

Easy installation

Like all devices from the measuring and monitoring portfolio, the three-phase monitoring relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. For further configuration options, additional settings can be made via dip-switches, offering the flexibility to configure, for example, the working principle of the relays and the output configuration. The device can be set up before installation in the application and easy adjustments during the process are possible.

ERC CATALOG MEASURING AND MONITORING REL AYS

107

-- Three-phase monitoring relays Benefits and advantages

Characteristics · True RMS (TRMS) measuring principle · Device for the use in mains with a frequency of 45-440 Hz
and where harmonics are to be expected1) · Adjustable phase unbalance threshold value · Adjustable ON-delay/OFF-delay time · Powered by the measuring circuit · 1 n/o contact, 1 or 2 c/o contacts · LEDs for the indication of operational states

· Multifunctional and singlefunctional devices · Phase failure detection · Phase sequence monitoring · Over- and undervoltage monitoring (fixed or adjustable) · Wide-range operating voltage guarantees
world-wide operation · Various approvals and marks
(1) devices CM-MPS.23 and CM-MPS.43

Applications
· Control for connection of moving equipment (e.g. air conditioning compressors, refrigerated trucks and containers, and cranes)
· Control against reverse motor operation (lifting, handling, elevators, escalators, etc.)

· Control of sensitive three-phase supplies · Overheating of the motor due to asymmetrical voltage · Protection of a plant against destruction due
to overvoltage · Direction of rotation of the drive

108

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays have many functions to protect various applications

ERC CATALOG MEASURING AND MONITORING REL AYS

109

-- Three-phase monitoring relays Function

Phase unbalance monitoring If the supply by the three-phase system is unbalanced due to an uneven distribution of the load, the motor will convert a part of the energy into reactive power. This energy gets lost unexploited; also the motor is exposed to higher thermal stress. Other thermal protection devices fail to detect continuing unbalances, which can lead to damage or destruction of the motor. The CM range three-phase monitors with phase unbalance monitoring can reliably detect this critical situation.
Phase sequence Changing the phase sequence during operation or a wrong phase sequence prior to startup causes a change of the rotational direction of the connected device. Generators, pumps or fans rotate in the wrong direction and the installation is no longer working properly. In particular, for moveable equipment, such as construction machinery, phase sequence detection prior to the startup process is highly reasonable.
Phase loss In case of phase loss, undefined stats of the installation are likely to occur; e.g. the startup process of motors is disturbed. All three-phase monitors of the ABB CM range detect a phase loss as soon as the voltage of one phase drops below 60 % of its nominal value.
Voltage monitoring All electric devices can be damaged when operated continuously in a network with out-of-range voltages. For example, safe starting is not ensured in case of undervoltage. Also, the switching state of a contactor is not clearly defined when operated in a "forbidden" voltage range. This can lead to undefined states of the installation and cause damage or destruction of valuable parts.
Selectable phase sequence monitoring The phase sequence monitoring can be switched off by means of a rotary switch or a DIP switch. This enables monitoring of three-phase mains where phase sequence is not relevant for the application, for example in case of motors with forward and reverse rotation, heating applications, etc.
Automatic phase sequence correction The automatic phase sequence correction is activated by means of a DIP switch. With activated phase sequence correction, it is e nsured that for any non-fixed or portable equipment, e.g. c onstruction machinery, the correct phase sequence is always applied to the input terminals of the load. For details regarding the wiring, please see function description / diagrams.

110

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Operating controls

-- S-range housing

Adjustment of the threshold value >U for overvoltage

Adjustment of the threshold value Asymetry for phase unbalance
DIP switches A ON-delay B OFF-delay l Phase sequence monitoring deactivated k Phase sequence monitoring activated m Phase sequence correction activated n Phase sequence correction deactivated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts

Adjustment of the threshold value <U for undervoltage
Indication of operational states R/T: red LED ­ Relay status / timing F1: yellow LED ­ Fault message F2: yellow LED ­ Fault message
Adjustment of the tripping delay T

ERC CATALOG MEASURING AND MONITORING REL AYS
-- Three-phase monitoring relays Operating controls
-- N-range housing
Adjustment of the threshold value >U for overvoltage
Adjustment of the threshold value <U for undervoltage
DIP switches A ON-delay B OFF-delay l Phase sequence monitoring deactivated k Phase sequence monitoring activated m Phase sequence correction activated n Phase sequence correction deactivated i 2x1 c/o (SPDT) contact j 1x2 c/o (SPDT) contacts

111
Adjustment of the threshold value Asymmetry for phase unbalance
Indication of operational states R/T: red LED ­ Relay status / timing F1: yellow LED ­ Fault message F2: yellow LED ­ Fault message
Adjustment of the tripping delay T

112

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Selection table - singlefunctional

CM-PAS.41P 1SVR740774R3300

CM-PAS.41S 1SVR730774R3300

CM-PAS.31P 1SVR740774R1300

CM-PAS.31S 1SVR730774R1300

CM-PVS.81P 1SVR740794R2300

CM-PVS.81S 1SVR730794R2300

CM-PVS.41P 1SVR740794R3300

CM-PVS.41S 1SVR730794R3300

CM-PVS.31P 1SVR740794R1300

CM-PVS.31S 1SVR730794R1300

CM-PSS.41P 1SVR740784R3300

CM-PSS.41S 1SVR730784R3300

CM-PSS.31P 1SVR740784R2300

CM-PSS.31S 1SVR730784R2300

CM-PFS.P 1SVR740824R9300

CM-PFS.S 1SVR730824R9300

CM-PFE.2 1SVR550826R9100

1SVR550824R9100

1SVR550871R9500

1SVR550870R9400

1SVR550882R9500

Order number 1SVR550881R9400

CM-PFE

CM-PVE

CM-PVE

CM-PBE

Type CM-PBE

Rated control supply voltage Us Phase to phase 160-300 V AC 200-400 V AC 200-500 V AC 208-440 V AC 300-500 V AC 320-460 V AC 380 V AC 380-440 V AC 400 V AC Phase to neutral 185-265 V AC 220-240 V AC Rated frequency 50/60 Hz Suitable for monitoring Single-phase mains Three-phase mains Monitoring function Phase failure Phase sequence Overvoltage Undervoltage Unbalance Neutral1) Thresholds adjustable (adj) or fixed (fix) Timing functions for tripping delay ON delay On and OFF delay Connection type Push-in terminals Double-chamber cage connection terminals

JJ

JJ

JJ

JJJ

J

JJ

JJ

JJ

JJ

JJ

JJ

J J

JJJJJJJJJJJJJJJJJJJJJJ
JJ JJJJJJJJJJJJJJJJJJJJJJ

JJJJJJJJJJJJJJJJJJJJJJ

J J J J sel sel sel sel sel sel sel sel sel sel J J J J

JJ

JJJJJJJJJJ

JJ

JJJJJJJJJJ

JJJJ

JJ

fix fix fix fix fix fix fix fix fix fix fix fix fix fix adj adj adj adj adj adj adj adj

fix fix

sel sel sel sel

fix fix fix fix fix fix

adj adj adj adj adj adj adj adj adj adj

JJJJJJJ JJJJJJJ

(1) The external conductor voltage towards the neutral conductor is measured.

adj: adjustable sel: selectable fix: fixed

ERC CATALOG MEASURING AND MONITORING REL AYS

113

-- Three-phase monitoring relays Ordering details - singlefunctional

CM-PBE CM-PSS.41P CM-PAS.31P

2CDC 251 064 V0011

2CDC 251 063 V0011

2CDC 251 064 V0011

Description The three-phase monitoring relays are designed for use in three-phase mains for monitoring the phase parameters like phase sequence, phase failure, over- and undervoltage, as well as phase unbalance.

-- Ordering details

Characteristics

Type

See selection table

CM-PBE CM-PBE CM-PVE CM-PVE CM-PFE CM-PFE.2

Order code
1SVR550881R9400 1SVR550882R9500 1SVR550870R9400 1SVR550871R9500 1SVR550824R9100 1SVR550826R9100

Weight (1 pc) kg (lb)
0.08 (0.17) 0.08 (0.17) 0.08 (0.17) 0.08 (0.17) 0.08 (0.17) 0.067 (0.147)

Characteristics

Type

See selection table
S: screw connection P: push-in connection

CM-PFS.S CM-PFS.P CM-PSS.31S CM-PSS.31P CM-PSS.41S CM-PSS.41P CM-PVS.31S CM-PVS.31P CM-PVS.41S CM-PVS.41P CM-PVS.81S CM-PVS.81P CM-PAS.31S CM-PAS.31P CM-PAS.41S CM-PAS.41P

Order code
1SVR730824R9300 1SVR740824R9300 1SVR730784R2300 1SVR740784R2300 1SVR730784R3300 1SVR740784R3300 1SVR730794R1300 1SVR740794R1300 1SVR730794R3300 1SVR740794R3300 1SVR730794R2300 1SVR740794R2300 1SVR730774R1300 1SVR740774R1300 1SVR730774R3300 1SVR740774R3300

Weight (1 pc) kg (lb) 0.127 (0.280) 0.119 (0.262) 0.132 (0.291) 0.123 (0.271) 0.132 (0.291) 0.123 (0.271) 0.141 (0.311) 0.132 (0.291) 0.139 (0.306) 0.131 (0.289) 0.136 (0.300) 0.128 (0.282) 0.133 (0.293) 0.124 (0.273) 0.132 (0.291) 0.123 (0.271)

114

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Selection table - multifunctional

CM-MPN.72P 1SVR760489R8300

CM-MPN.72S 1SVR750489R8300

CM-MPN.62P 1SVR760488R8300

CM-MPN.62S 1SVR750488R8300

CM-MPN.52P 1SVR760487R8300

CM-MPN.52S 1SVR750487R8300

CM-MPS.43P 1SVR740884R4300

CM-MPS.43S 1SVR730884R4300

CM-MPS.23P 1SVR740885R4300

CM-MPS.23S 1SVR730885R4300

CM-MPS.41P 1SVR740884R3300

CM-MPS.41S 1SVR730884R3300

CM-MPS.31P 1SVR740884R1300

CM-MPS.31S 1SVR730884R1300

CM-MPS.21P 1SVR740885R3300

CM-MPS.21S 1SVR730885R3300

CM-MPS.11P 1SVR740885R1300

CM-MPS.11S 1SVR730885R1300

Order number

Type

Rated control supply voltage Us Phase to phase 160-300 V AC 300-500 V AC 350-580 V AC 450-720 V AC 530-820 V AC Phase to neutral 90-170 V AC 180-280 V AC Rated frequency 50/60 Hz 50/60/400 Hz Suitable for monitoring Mains with harmonic content Single-phase mains Three-phase mains Monitoring function Phase failure Phase sequence Automatic phase sequence correction Overvoltage Undervoltage Unbalance Interrupted neutral monitoring 1) Thresholds Adjustable (adj) Timing functions for tripping delay On- or OFF delay Connection type Push-in terminals Double-chamber cage connection terminals

JJ JJ

JJ JJ JJ JJ

JJ

JJ

JJ

JJJJJJJJ

JJJJJJ

JJJJ

JJJJ

JJJJ

JJ

JJJJJJJJJJJJJJJJJJ

JJJJJJJJJJJJJJJJJJ

sel sel sel sel sel sel sel sel adj adj adj adj adj adj adj adj adj adj

adj adj adj adj adj adj adj adj adj adj

JJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJ

JJJJJJJJJJJJJJJJJJ

JJJJ

JJ

adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj

adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj adj

JJJJJJJJJ JJJJJJJJJ

1) The relay detects by means of a phase unbalance the interruption of the neutral conductor. The external conductor voltage towards the neutral conductor is measured too.

adj: adjustable sel: selectable

ERC CATALOG MEASURING AND MONITORING REL AYS

115

-- Three-phase monitoring relays Ordering details - multifunctional

CM-MPS.23P CM-MPN.52P

2CDC 251 065 V0011

2CDC 251 062 V0011

Description The three-phase monitoring relays are designed for use in three-phase mains for monitoring the phase parameters, such as phase sequence, phase failure, over- and undervoltage, as well as phase unbalance.

-- Ordering details

Characteristics

Type

See selection table
S: screw connection P: push-in connection

CM-MPS.11S CM-MPS.11P CM-MPS.21S CM-MPS.21P CM-MPS.31S CM-MPS.31P CM-MPS.41S CM-MPS.41P CM-MPS.23S CM-MPS.23P CM-MPS.43S CM-MPS.43P CM-MPN.52S CM-MPN.52P CM-MPN.62S CM-MPN.62P CM-MPN.72S CM-MPN.72P

Order code
1SVR730885R1300 1SVR740885R1300 1SVR730885R3300 1SVR740885R3300 1SVR730884R1300 1SVR740884R1300 1SVR730884R3300 1SVR740884R3300 1SVR730885R4300 1SVR740885R4300 1SVR730884R4300 1SVR740884R4300 1SVR750487R8300 1SVR760487R8300 1SVR750488R8300 1SVR760488R8300 1SVR750489R8300 1SVR760489R8300

Weight (1 pc) kg (lb) 0.148 (0.326) 0.137 (0.302) 0.146 (0.322) 0.135 (0.298) 0.142 (0.313) 0.133 (0.293) 0.140 (0.309) 0.132 (0.291) 0.149 (0.328) 0.138 (0.304) 0.148 (0.327) 0.137 (0.302) 0.230 (0.507) 0.226 (0.498) 0.229 (0.505) 0.225 (0.496) 0.224 (0.494) 0.220 (0.485)

116

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical data

Type

CM-PBE1) CM-PBE

CM-PVE1) CM-PVE

CM-PFE

CM-PFE.2

Input circuit - supply circuit

L1-L2-L3-N L1-L2-L3 L1-L2-L3-N L1-L2-L3

Rated control supply voltage US = measuring voltage

3x380440 V AC, 220-240 V AC

3x380440 V AC

3x320460 V AC, 185-265 V AC

3x320460 V AC

3x208440 V AC

3x200500 V AC

Power consumption

13 mA / 9 VA

Rated control supply voltage US tolerance Rated frequency

-15...+15 % 50/60 Hz

-15...+10 % 50/60 Hz (-10...+10 %)

50/60 Hz

Duty time

100 %

Input circuit - measuring circuit Monitoring functions
Measuring ranges

L1-L2-L3-N L1-L2-L3

J phase failure

J

phase sequence -

-

over- / undervoltage -

-

neutral J

-

3x380-440 3x380V AC, 220- 440 V AC 240 V AC

L1-L2-L3-N L1-L2-L3

J

J

-

-

J

J

J

-

3x320460 V AC, 185-265 V AC

3x320460 V AC

J J
-
-
3x208440 V AC

J J
-
-
3x200500 V AC

Thresholds

Umin 0.6 x UN

fixed 185 V / 320 V

fixed 320 V

0.6 x UN

Umax -

fixed

fixed

-

265 V /

460 V

460 V

Hysteresis related to the threshold value Measuring voltage frequency

fixed 5 %

fixed 5 %

(release value = 0.65 x UN)

50/60 Hz (-10 %...+10 %)

50/60 Hz

Response time

40 ms

80 ms

500 ms

Accuracy within the temperature range

-

U m 0.06 % / °C

Timing circuit

Start-up delay tS Tripping tV

fixed 500 ms (w20 %)
fixed 150 ms (w20 %)

at over-/ undervoltage fixed 500 ms (w20 %)

fixed 500 ms fixed 500 ms

Indication of operational states

Relay status

R: yellow LED V output relay energized

Fault message

F: red LED Only CM-PFS: V phase failure / V phase sequence error

CM-PFS
approx. 15 VA
J J
-
-

ERC CATALOG MEASURING AND MONITORING REL AYS

117

-- Three-phase monitoring relays Technical data

Type Output circuits

CM-PBE1) 13-14

CM-PBE

CM-PVE1) CM-PVE

CM-PFE 11-12/14

CM-PFE.2

Kind of output

1 n/o contact

1 c/o contact

Operating principle

closed-circuit principle2)

Minimum switching voltage / Minimum switching current

24 V / 10 mA

Maximum switching voltage / maximum switching voltage

see data sheets

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A
DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC rating (UL 508)

Utilization category (Control Circuit B 300 pilot duty, general purpose 250 V, 4 A, cos phi 0.75 Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current at B 300 5 A

max. making/breaking apparent 3600/360 VA power at B 300

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 10 A fast-acting n/o contact 10 A fast-acting

6 A fast-acting

Conventional thermal current Ith

4 A

1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured. 2) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold.

CM-PFS
1115-1216 / 1418, 2125-2226 / 2428
2 c/o contacts

118

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical data

Type General data Duty cycle Dimensions Mounting Mounting position Minimum distance to other unites

CM-PBE1) CM-PBE CM-PVE1) CM-PVE
100 % see dimensional drawings DIN rail (IEC/EN 60715) any horizontal not necesarry

Degree of protection Electrical connection Connecting capacity
Stripping length

housing / terminals IP50 / IP20
fine-strand with wire end 2 x 0.75-1.5 mm² (2 x 18-16 AWG) ferrule
fine-strand without wire end 2 x 1-1.5 mm² (2 x 18-16 AWG) ferrule rigid 2 x 0.75-1.5 mm² (2 x 18-16 AWG) 10 mm (0.39 in)

Tightening torque Environmental data Ambient temperature range Climatic class Damp heat Damp heat, cyclic Vibration withstand Vibration, sinusoidal Shock Isolation data Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Basic insulation
Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive

0.6-0.8 Nm
operation / storage -20..+60 °C / -40...+85 °C -
IEC/EN 60068-2-30 40 °C, 93 % RH, 4 days IEC/EN 60068-2-30
IEC/EN 60068-2-6 10-57 Hz: 0.075 mm; 57-150 Hz: 1 g -
between input, 400 V measuring and output circuits
input circuit / output circuit output circuit 1 / output circuit 2 between input, 4 kV / 1.2 -50 s measuring and output circuits input circuit / output circuit output circuit 1 / output circuit 2 supply circuit / output circuit
3 III
IEC/EN 60947-5-1, EN 50178 2014/35/EU 2014/30/EU 2011/65/EU

CM-PFE CM-PFE.2 CM-PFS

 10 mm if ambient

 10 mm in

temperature > 50 °C and case of

rated operational currents > 2 A

continuous measuring voltage

> 440 V

Same as CM-PSS.31

Same as CM-PSS.31

3K3 6 x 24 h cycle, 55 °C, 95 % RH class 2 class 2
-

600 V -

300 V

6 kV

4 kV 600 V AC

IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178

ERC CATALOG MEASURING AND MONITORING REL AYS

119

-- Three-phase monitoring relays Technical data

Type Electromagnetic compatibility Interference immunity to
electrostatic discharge radiated, radio-frequency, electromagnetic field

CM-PBE1) CM-PBE CM-PVE1) CM-PVE
IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 3 - 6 kV/ 8 kV IEC/EN 61000-4-3 level 3 - 10 V/m

electrical fast transient / burst IEC/EN 61000-4-4 level 3 - 2 kV / 5 kHz

surge

IEC/EN 61000-4-5 level 4 - 2 kV L-L

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3 - 10 V

voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-11 -

harmonics and interharmonics IEC/EN 61000-4-13 -

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, Class B EN 55022

high-frequency conducted

IEC/CISPR 22, Class B EN 55022

(1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured.

CM-PFE

CM-PFE.2 CM-PFS
level 3 10 V/m (1 GHz) 3 V/m (2 GHz) 1 V/m (2.7 GHz)
class 3
class 3

120

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical data

Type

CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41

Input circuit = Measuring circuit

L1, L2, L3

Rated control supply voltage US = measuring voltage

3x380 V AC 3x400 V AC 3x160300 V AC

3x300500 V AC

3x200400 V AC

3x160300 V AC

3x300500 V AC

Rated control supply voltage US tolerance Rated frequency

-15...+10 % 50/60 Hz

Frequency range

45-65 Hz

Typical current / power consumption

25 mA / 25 mA / 25 mA / 10 25 mA / 19 mA / 25 mA / 25 mA

18 VA

18 VA

VA

18 VA

10 VA

10 VA

/18 VA

(380 V AC) (400 V AC) (230 V AC) (400 V AC) (300 V AC) (230 V AC) (400 V AC)

Measuring circuit

L1, L2, L3

Monitoring functions

J Phase failure

J

J

J

J

J

J

Phase sequence can be switched off

J

J

Automatic phase sequence -

-

-

-

-

-

-

correction

J Over- / undervoltage

J

J

J

J

-

-

Phase unbalance -

-

-

-

-

J

J

Neutral -

-

-

-

-

-

-

Measuring range

Overvoltage 3x418 V AC 3x440 V AC 3x220-

3x420-

3x300-

-

-

300 V AC 500 V AC 400 V AC

Undervoltage 3x342 V AC 3x360 V AC 3x160-

3x300-

3x210-

-

-

230 V AC 380 V AC 300 V AC

Phase -

-

-

-

-

2-25 % of average

unbalance

of phase voltages

Thresholds

Overvoltage fixed

adjustable within measuring range -

-

Undervoltage fixed

adjustable within measuring range -

-

Phase unbalance -

-

-

-

-

adjust. within

(switch-off value)

measuring range

Tolerance of the adjusted threshold value

6 % of full-scale value

Hysteresis related to the threshold value

Over- / undervoltage fixed 5 %

-

Phase unbalance -

-

-

-

-

fixed 20 %

Maximum measuring cycle time

100 ms

Accuracy within the temperature range

U  0.06 % / °C

Measuring method

true RMS

Timing circuit

Start-up delay tS Tripping delay tV

fixed 200 ms
ON- or OFF-delay 0; 0.1-30 s adjustable

ON- delay 0; 0.1-30 s adjustable

Repeat accuracy (constant parameters)

-

-

-

-

< w 0.2 % -

-

Accuracy within the rated control supply voltage tolerance t  0.5 %

Accuracy within the temperature range

t  0.06 % / °C

Indication of operational states

1 yellow LED, 2 red LEDs

details see function

details see operating mode and

description / -diagrams function description / -diagrams

details see function description / -diagrams

Output circuits

15-16/18, 25-26/28

Kind of output Operating principle

relay, 2 x 1 c/o contact closed-circuit principle1)

Contact material

AgNi alloy, Cd free

Minimum switching power

24 V / 10 mA

Maximum switching voltage

see "Load limit curves"

1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value

ERC CATALOG MEASURING AND MONITORING REL AYS

121

-- Three-phase monitoring relays Technical data

Type

CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41

Rated operational voltage Ue and AC-12 (resistive) 230 V 4 A

rated operational current Ie

AC-15 (inductive) 230 V 3 A

DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC rating (UL 508)

Utilization category B 300 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current at B 300 5 A

max. making/breaking 3600/360 VA apparent power at B 300

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

General data

MTBF

on request

Duty cycle

100%

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

horizontal 10 mm (0.39 in) in case of continuous measuring voltages

> 400 V

> 400 V

> 220 V

> 400 V

-

> 220 V

> 400 V

Material of housing

UL 94 V-0

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Wire size

Screw connection technology

Easy Connect Technology (Push-in)

fine-strand with(out) wire 1 x 0.5-2.5 mm² (1 x 18-14 AWG) end ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG)

2 x 0.5-1.5 mm² (2 x 18-16 AWG)

rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)

2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (7.08 lb.in)

-

Environmental data

Ambient temperature ranges

operation / storage -25...+60 °C / -40...+85 °C

Damp heat, cyclic (IEC 60068-2-30)

6 x 24 h cycle, 55 °C, 95 % RH

Climatic class

3K3

Vibration (sinusoidal)

class 2

Shock

class 2

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 600 V output circuit 1 / output circuit 2 300 V

Rated impulse withstand voltage Uimp

input circuit 6 kV; 1.2/50 s output circuit 4 kV; 1.2/50 s

Basic insulation

input circuit / output circuit 600 V

Protective separation

input circuit / output circuit

Pollution degree

3

Overvoltage category

III

122

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical data

Type

CM-PSS.31 CM-PSS.41 CM-PVS.31 CM-PVS.41 CM-PVS.81 CM-PAS.31 CM-PAS.41

Standards / Directives

Standards

IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178

Low Voltage Directive

2014/35/EU

EMC directive

2014/30/EU

RoHS directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

EN 61000-6-1

electrostatic discharge

IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3 (10 V/m)

electrical fast transient / burst

IEC/EN 61000-4-4 Level 3 (2 kV / 2 kHz)

surge

IEC/EN 61000-4-5 Level 4 (2 kV L-L)

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 Level 3 (10 V)

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 class B

high-frequency conducted

IEC/CISPR 22, EN 55022 class B

ERC CATALOG MEASURING AND MONITORING REL AYS

123

-- Three-phase monitoring relays Technical data

Type

CM-MPS.11

CM-MPS.21

CM-MPS.31

Input circuit = Measuring circuit

L1, L2, L3, N

L1, L2, L3

Rated control supply voltage US = measuring voltage

3x90-170 V AC

3x180-280 V AC

3x160-300 V AC

Rated control supply voltage US tolerance

-15...+10 %

Rated frequency

50/60 Hz

Frequency range

45-65 Hz

Typical current / power consumption

25 mA / 10 VA (115 V AC)

25 mA / 18 VA (230 V AC)

25 mA / 10 VA (230 V AC)

Measuring circuit Monitoring functions

L1, L2, L3, N

J Phase failure

J

L1, L2, L3
J

Phase sequence can be switched off

Automatic phase sequence -

-

-

correction

J Over- / undervoltage

J

J

J Phase unbalance

J

J

J Interrupted neutral

J

-

Measuring range

Overvoltage 3x120-170 V AC

3x240-280 V AC

3x220-300 V AC

Undervoltage 3x90-130 V AC

3x180-220 V AC

3x160-230 V AC

Phase unbalance 2-25 % of average of phase voltages

Thresholds

Overvoltage adjustable within measuring range

Undervoltage adjustable within measuring range

Phase unbalance (switch-off value) adjustable within measuring range

Tolerance of the adjusted threshold value

6 % of full-scale value

Hysteresis related to the threshold value

Over- / undervoltage fixed 5 % Phase unbalance fixed 20 %

Accuracy within the temperature range

U  0.06 % / °C

Measuring method

True RMS

Timing circuit

Start-up delay tS

fixed 200 ms

Tripping delay tV

ON- or OFF-delay 0; 0.1-30 s adjustable

Accuracy within the rated control supply voltage tolerance t  0.5 %

Accuracy within the temperature range

t  0.06 % / °C

Indication of operational states

Details see function description / -diagrams

Output circuits

15-16/18, 25-26/28

Kind of output

relay, 1 x 2 c/o contacts

Operating principle

closed-circuit principle1)

Contact material

AgNi alloy, Cd free

Minimum switching power

24 V / 10 mA

Maximum switching voltage

see load limit curves

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A

DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC rating (UL 508)

Utilization category B 300 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current 5 A at B 300

max. making/breaking 3600/360 VA apparent power at B 300

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Max. fuse rating to achieve shortcircuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value

CM-MPS.41
3x300-500 V AC
25 mA / 18 VA (400 V AC)
J
-
J J
3x420-500 V AC 3x300-380 V AC

124

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical data

Type General data

CM-MPS.11

CM-MPS.21

CM-MPS.31

CM-MPS.41

MTBF Duty time

on request 100 %

Dimensions

see dimension drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units
Material of housing Degree of protection

horizontal 10 mm (0.39 in) in case of continuous measuring voltages

> 120 V

> 240 V

> 220 V

UL 94 V-0

housing / terminals IP50 / IP20

> 400 V

Electrical connection Wire size
Stripping length Tightening torque

Screw connection technology fine-strand with(out) wire end 1 x 0.5-2.5 mm² (1 x 18-14 AWG)
ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 8 mm (0.32 in)
0.6-0.8 Nm (7.08 lb.in)

Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG)
-

Environmental data Ambient temperature ranges Damp heat, cyclic

operation / storage -25...+60 °C / -40...+85 °C 6 x 24 h cycle, 55 °C, 65 % RH

Climatic class

3K3

Vibration Shock

class 2 class 2

Isolation data

Rated insulation

input circuit / output circuit 600 V

voltage Ui

output circuit 1 / output circuit 2 300 V

Rated impulse withstand

input circuit 6 kV; 1.2/50 s

voltage Uimp

output circuit 4 kV; 1.2/50 s

Test voltage between all isolated circuits (routine test)

2.5 kV, 50 Hz, 1 s

Basic insulation

input circuit / output circuit 600 V

Protective separation (IEC/EN

input circuit / yes

-

61140, EN 50178) Pollution degree

output circuit 3

Overvoltage category

III

Standards / Directives Standards Low Voltage Directive

IEC/EN 60255-2, IEC/EN 60947-5-1, EN 50178 2014/35/EU

EMC directive

2014/30/EU

RoHS directive

2011/65/EU

Electromagnetic compatibility Interference immunity to
electrostatic discharge

IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 3 (6 kV / 8 kV)

radiated, radio-frequency,
electromagnetic field electrical fast transient / burst

IEC/EN 61000-4-3 level 3 (10 V/m) IEC/EN 61000-4-4 level 3 (2 kV / 2 kHz)

surge

IEC/EN 61000-4-5 level 4 (2 kV L-N)

Level 4 (2 kV L-L)

conducted disturbances, induced by radio-frequency fields harmonics and interharmonics

IEC/EN 61000-4-6 level 3 (10 V) IEC/EN 61000-4-13 class 3

Interference emission

EN 61000-6-3, EN 61000-6-4

high-frequency radiated high-frequency conducted

IEC/CISPR 22, class B EN 55022
IEC/CISPR 22, class B EN 55022

ERC CATALOG MEASURING AND MONITORING REL AYS

125

-- Three-phase monitoring relays Technical data

Type

CM-MPS.23

CM-MPS.43

CM-MPN.52

Input circuit = Measuring circuit

L1, L2, L3, N

L1, L2, L3

Rated control supply voltage US = measuring voltage

3x180-280 V AC 3x300-500 V AC 3x350-580 V AC

Rated control supply voltage US tolerance

-15...+10 %

Rated frequency

50/60/400 Hz

50/60 Hz

Frequency range

45-440 Hz

45-65 Hz

Typical current / power consumption

5 mA / 4 VA (230 V AC)

5 mA / 4 VA (400 V AC)

29 mA / 41 VA (480 V AC)

Measuring circuit
Monitoring functions

L1, L2, L3, N

L1, L2, L3

J Phase failure

J

J

Phase sequence can be switched off

Automatic phase sequence correction configurable

J Over- / undervoltage

J

J

J Phase unbalance

J

J

J Interrupted neutral

-

-

Measuring range

Overvoltage 3x240-280 V AC 3x420-500 V AC 3x480-580 V AC

Undervoltage 3x180-220 V AC 3x300-380 V AC 3x350-460 V AC

Phase unbalance 2-25 % of average of phase voltages

Thresholds

Overvoltage adjustable within measuring range

Undervoltage adjustable within measuring range

Phase unbalance (switch-off value) adjustable within measuring range

Tolerance of the adjusted thrshold value

6 % of full-scale value

Hysteresis related to the threshold value

Over- / undervoltage fixed 5 % Phase unbalance fixed 20 %

Maximum measuring cycle time

100 ms

Accuracy within the temperature range

U  0.06 % / °C

Measuring method

True RMS

Timing circuit

Start-up delay tS and tS2

fixed 200 ms

Start-up delay tS1

fixed 250 ms

Tripping delay tV

ON- or OFF-delay 0; 0.1-30 s adjustable

Accuracy within the rated control supply voltage tolerance t  0.5 %

Accuracy within the temperature range

t  0.06 % / °C

Indication of operational states

Details see function description / -diagrams

Output circuits

15-16/18, 25-26/28

Kind of output

relay, 2 x 1 or 1 x 2 c/o contacts configurable

Operating principle

closed-circuit principle1)

Contact material

AgNi alloy, Cd free

Minimum switching power

24 V / 10 mA

Maximum switching voltage

see load limit curves

Rated operational voltage Ue and AC-12 (resistive) 230 V 4 A

rated operational current Ie

AC-15 (inductive) 230 V 3 A

DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC rating (UL 508)

Utilization category B 300 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current 5 A at B 300

max. making/breaking apparent 3600/360 VA power at B 300

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

10 A fast-acting

1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value

CM-MPN.62
3x450-720 V AC
29 mA / 52 VA (600 V AC)
J
J J
3x600-720 V AC 3x450-570 V AC

CM-MPN.72
3x530-820 V AC
29 mA / 59 VA (690 V AC)
J
J J
3x690-820 V AC 3x530-660 V AC

126

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical data

Type

CM-MPS.23

CM-MPS.43

CM-MPN.52

CM-MPN.62

CM-MPN.72

General data

MTBF

on request

Duty time

100 %

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

horizontal 10 mm (0.39 in)

not necessary

Material of housing

UL 94 V-0

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Wire size

Screw connection technology

Easy Connect Technology (Push-in)

fine-strand with(out) wire end 1 x 0.5-2.5 mm² (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 20-16 AWG)

2 x 0.5-1.5 mm² (2 x 18-16 AWG)

rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)

2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (7.08 lb.in)

-

Environmental data Ambient temperature ranges

operation / storage -25...+60 °C / -40...+85 °C

Damp heat, cyclic (IEC 60068-2-30)

6 x 24 h cycles, 55 °C, 95 % RH

Climatic category

3K3

Vibration (sinusoidal) (IEC/EN 60255-21-1)

class 2

Shock (IEC/EN 60255-21-2)

class 2

Isolation data Rated insulation v oltage Ui

input circuit / 600 V output circuit

1000 V

output circuit 1 / 2 300 V

Rated impulse withstand voltage Uimp

input circuit 6 kV; 1.2/50 s output circuit 4 kV; 1.2/50 s

8 kV; 1.2/50 s

Basic insulation

input circuit / output circuit 600 V

1000 V

Protective separation (IEC/EN 61140, EN 50148)

input circuit / output circuit

Pollution degree

3

Overvoltage category

III

Standards / Directives

Standards

IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 3 (6 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient / burst

IEC/EN 61000-4-4 level 3 (2 kV / 2 kHz)

surge

IEC/EN 61000-4-5 level 4 (2 kV L-N) Level 4 (2 kV L-L)

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3 (10 V)

harmonics and interharmonics

IEC/EN 61000-4-13 class 3

Interference emission

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 class B

high-frequency conducted

IEC/CISPR 22, EN 55022 class B

ERC CATALOG MEASURING AND MONITORING REL AYS

127

-- Three-phase monitoring relays Technical diagrams

-- Connection diagrams

CM-PBE, CM-PVE
with neutral

without neutral

CM-PFE

1SVC 110 000 F0117

1SVC 110 000 F 0113

1SVC 110 000 F 0112

L1, L2, L3, (N) Control supply voltage = Measuring voltage

13-14

Output contact - closed-circuit principle

CM-PVS.x1, CM-PSS.x1, CM-PAS.x1

L1

L2

L3

L1 L2 L3 15 25

2CDC 252 037 F0b08
2CDC 252 037 F0b08

16 18 26 28

26

25

28

16

15

18

L1, L2, L3
15-16/18 25-26/28

Control supply voltage = Measuring voltage Output contact - closed-circuit principle

CM-MPS.11, CM-MPS.21, CM-MPS.23
L1 L2 L3 N L1 L2 L3 15 25

2CDC 252 036 F0b08
2CDC 252 036 F0b08

N 16 18 26 28
26 25 28 16 15 18

L1, L2, L3, (N)
15-16/18 25-26/28

Control supply voltage = Measuring voltage Output contact - closed-circuit principle

CM-MPN.x2

L1

L2

L3

L1 L2 L3 15 25

2CDC 252 038 F0b08
2CDC 252 038 F0b08

16 18 26 28

16 15 18 26 25 28

L1, L2, L3
15-16/18 25-26/28

Control supply voltage = Measuring voltage Output contact - closed-circuit principle

L1, L2, L3 Control supply voltage = Measuring voltage 11-12/14 Output contact - closed-circuit principle
CM-PFS

1SVC 110 000 F 0118

L1, L2, L3
1115-1216 /1418 2125-2226/2428

Control supply voltage = Measuring voltage Output contact - closed-circuit principle

CM-MPS.31, CM-MPS.41, CM-MPS.43
L1 L2 L3 L1 L2 L3 15 25

2CDC 252 037 F0b08
2CDC 252 037 F0b08

16 18 26 28
26 25 28 16 15 18

L1, L2, L3, (N)
15-16/18 25-26/28

Control supply voltage = Measuring voltage Output contact - closed-circuit principle

128

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Technical diagrams

-- Rotary switch "Function"

CM-PVS
ON-delay with phase sequence monitoring
OFF-delay with phase sequence monitoring
ON-delay without phase sequence monitoring
OFF-delay without phase sequence monitoring

CM-PSS
ON-delay with phase sequence monitoring
OFF-delay with phase sequence monitoring
ON-delay without phase sequence monitoring
OFF-delay without phase sequence monitoring

-- DIP switch functions

CM-MPS.x3 and CM-MPN.x2

Position

4

3

2

1

ON

OFF

CM-MPS.x1

Position

2

1

ON

OFF

22CCDDC 2252 04411 F00bb0088 2CDC 2252 04400FF00bb0088

1 Timing function ON ON-delayed OFF OFF-delayed
2 Phase sequence monitoring ON deactivated OFF activated
3 Operating principle of output
ON 2x1 c/o contact OFF 1x2 c/o contact
4 Phase sequence correction
ON activated OFF deactivated
Output relay R1 is responsive to overvoltage, output relay R2 is responsive to undervoltage. In case of other faults, both output relays react synchronously.

1 Timing function
ON ON-delayed OFF OFF-delayed
2 Phase sequence monitoring ON deactivated OFF activated

ERC CATALOG MEASURING AND MONITORING REL AYS

129

-- Three-phase monitoring relays Function diagrams

CM-PBE

L1, L2, L3, N Measuring value
with neutral
13-14 R: yellow LED

L1, L2, L3, N ts

L1, L2, N L1, L2, L3, N L2, L3, N

L3

L1

tv

<ts

ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 150 ms

L1, L2, L3, N ts

L1, L2 L1, L2, L3, N L3
N
<tv

L1, L2, L3 Measuring value

without

neutral

13-14

R: yellow LED

L1, L2, L3 ts

L1, L2 L3
tv

L1, L2, L3 <ts

L1, L2 L3

ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 150 ms

L1, L2, L3 ts

L1, L2 L1, L2, L3 L3
<tv

2CDC 252 046 F0203

2CDC 252 045 F0203

Phase failure detection If all phases (and the neutral) are present, the output relay energizes after the start-up delay ts is complete. If a phase failure occurs, the tripping delay tv starts. When timing is complete, the output relay de-energizes. As soon as the voltage returns to the tolerance range, timing of ts starts. When timing is complete, the output relay re-energizes automatically. The yellow LED glows when the output relay is energized.

CM-PVE

L1, L2, L3, N
Umax Umax - 5 %

Measuring value

with neutral

Umin + 5 % Umin

13-14

R: yellow LED

L1, L2, L3
Umax Umax - 5 %

Measuring value

without

Umin + 5 % Umin

neutral

13-14

R: yellow LED

ts

tv

<ts

ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms

ts

tv

<ts

ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms

ts

<tv

tv

ts

ts

<tv

tv

ts

CM-PFE, CM-PFE.2

L1, L2, L3 Measuring value
11-14 11-12 R: yellow LED

L1, L2, L3 ts

L1, L3, L2 tv

L1, L2, L3 ts

ts = Start-up delay fixed 500 ms tv = Tripping delay fixed 500 ms

L1, L2

tv

L3

L1, L2, L3 ts

CM-PFS

L1, L2, L3 Measuring value
11-14 11-12 21-24 21-22 R: yellow LED

L1, L2, L3 ts

L1, L3, L2 L1, L2, L3

L1, L2 L3

L1, L2, L3

L1 L2, L3

ts = start-up delay fixed 500 ms

L1, L2, L3

ATTENTION
If several CM-PFS units are placed side by side and the control supply voltage is higher than 415 V, spacing of at least 10mm has to be kept between the individual units.

2CDC 252 013 F0208

2CDC 252 061 F0208

2CDC 252 048 F0203

2CDC 252 047 F0203

Phase failure, under- / overvoltage detection If all phases (and the neutral) are present with correct voltage, the output relay energizes after the start-up delay ts is complete. If the voltage exceeds or falls below the fixed threshold value or if a phase failure occurs, the tripping delay tv starts. When timing is complete, the output relay deenergizes. As soon as the voltage returns to the tolerance range, timing of ts starts. When timing is complete, the output relay re-energizes automatically. The yellow LED glows when the output relay is energized.
Phase failure detection, phase sequence monitoring If all phases are present with the correct phase sequence, the output relay energizes after the start-up delay ts is complete. If a phase failure or a phase sequence error occurs, the tripping delay tv starts. When timing is complete, the output relay de-energizes. The yellow LED glows when the output relay is energized. In case of motors which continue running with only two phases, the CM-PFE detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage.
Phase failure detection, phase sequence monitoring If all phases are present with the correct phase sequence, the output relay energizes after the start-up delay ts is complete. If a phase failure or a phase sequence error occurs, the output relay de-energizes instantaneous. The yellow LED glows when the output relay is energized. In case of motors which continue running with only two phases, the CM-PFS detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage.

130

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Function diagrams

CM-PSS.xx, CM-PVS.xx, CM.PAS.xx, CM-MPS.xx, CM-MPN.xx

L1, L2, L3 Measuring value
15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED

L1, L2, L3 ts

L1, L3, L2 L1, L2, L3

L1, L2 L3

L1, L2, L3

L1 L2, L3

ts = start-up delay fixed 200 ms

L1, L2, L3

2CDC 252 094 F0207

Phase sequence monitoring and phase failure detection Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage, the output relays energize and the yellow LED R/T glows.
Phase sequence monitoring If phase sequence monitoring is activated, the output relays de-energize as soon as a phase sequence error occurs. The fault is displayed by alternated flashing of the LEDs F1 and F2. The output relays re-energize automatically as soon as the phase sequence is correct again.

CM-MPS.11, CM-MPS.21, CM-MPS.23

Phase failure detection The output relays de-energize instantaneous if a phase failure o ccurs. The fault is indicated by lighting of LED F1 and flashing of LED F2. The output relays re-energize automatically as soon as the voltage returns to the tolerance range.

Displacement of the star point

Interrupted neutral monitoring The interruption of the neutral in the main to be monitored is detected by means of phase unbalance evaluation. Determined by the system, in case of unloaded neutral (i.e. symmetrical load between all three phases) it may happen that an interruption of the neutral will not be detected. If the star point is displaced an asymmetrical load in the three-phase main, an interrupted neutral will be detected.

ERC CATALOG MEASURING AND MONITORING REL AYS

131

-- Three-phase monitoring relays Function diagrams

CM-MPS.x3, CM-MPN.x2

L1, L2, L3 Measuring value
15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED

L1, L2, L3 tS1 tS2

L1, L2 L3

L1, L2, L3

tS1 = start-up delay of R1 fixed 250 ms tS2 = start-up delay of R2 fixed 200 ms

tS1 tS2

L1, L3, L2

L1 L2 L3
K1
15 18
16

25

K1

28

26

K1 N

A1

A1

K2

K3

H1

A2

A2

Control circuit diagram (K1 = CM-MPS.23)

L1 L2 L3
K1
15 18
16

25

K1

28

26

K1 N

A1

A1

K2

K3

H1

A2

A2

Control circuit diagram (K1 = CM-MPS.43 or CM-MPN.xx)

2CDC253009F0014

2CDC253008F0014

2CDC 252 085 F0207

Automatic phase sequence correction This function can be selected only if phase sequence monitoring is activated k and operating mode 2x1 c/o (SPDT) contact j is selected.
Applying control supply voltage begins the fixed start-up delay tS1. When tS1 is complete and all phases are present with correct voltage, output relay R1 energizes. Output relay R2 energizes when the fixed start-up delay tS2 is complete and all phases are present with the correct phase sequence. Output relay R2 remains de-energized if the phase sequence is incorrect.
If the voltage to be monitored exceeds or falls below the set threshold values for phase unbalance, over- or undervoltage or if a phase failure occurs, output relay R1 de-energizes and the LEDs F1 and F2 indicate the fault. Output relay R2 is responsive only to a false phase sequence. In conjunction with a reversing contactor combination, this enables an automatic correction of the rotation direction. See circuit diagrams on the right.

2CDC 252 087 F0b07

L1 L2 L3
135
-F1
246
135
-K2 2 4 6

135
-K3 2 4 6

154
-F2
326

97 95 98 96

-M1

W1

V1

M

U1 3 ~

Power circuit diagram

2CDC252087F0b07

132

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Function diagrams

CM-PSS.xx (1), CM-PVS.xx (2), CM-MPS.xx (2), CM-MPN.xx (2)

ON-delay A, 1x2 c/o contacts j

2CDC 252 090 F0207

L1, L2, L3 > U
> U - 5 %
Measuring value < U + 5 % < U
15-18 15-16 25-28 25-26
F1: red LED F2: red LED R/T: yellow LED

ts

tv

ts = start-up delay fixed 200 ms tv = adjustable tripping delay

<tv

tv

OFF-delay B, 1x2 c/o contacts j

L1, L2, L3 > U
> U - 5 %
Measuring value < U + 5 % < U
15-18 15-16 25-28 25-26
F1: red LED F2: red LED R/T: yellow LED

ts

tv

ts = start-up delay fixed 200 ms tv = adjustable tripping delay

<tv

<tv

2CDC 252 091 F0207

Over- and undervoltage monitoring j Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with the correct phase sequence, the output relays energize and the yellow LED R/T glows.
Type of tripping delay = ON-delay If the voltage to be monitored exceeds or falls below the fixed (1) or set (2) threshold value, the output relays de-energize after the set tripping delay tV is complete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 % and the LED R/T glows.
Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the fixed (1) or set (2) threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage returns to the t olerance range, taking into account a fixed hysteresis of 5 %, the output relays re-energize a utomatically after the set tripping delay tV is complete. The LED R/T flashes during timing and turns steady when timing is complete.

ERC CATALOG MEASURING AND MONITORING REL AYS

133

-- Three-phase monitoring relays Function diagrams

CM-MPS.x3, CM-MPN.x2

ON-delay A, 2x1 c/o contact i

L1, L2, L3 > U
> U - 5 %
Measuring value < U + 5 % < U
15-18 15-16 25-28 25-26
F1: red LED F2: red LED R/T: yellow LED

ts

tv

ts = start-up delay fixed 200 ms tv = adjustable tripping delay

<tv

tv

OFF-delay B, 2x1 c/o contact i

L1, L2, L3 > U
> U - 5 %
Measuring value < U + 5 % < U
15-18 15-16
25-28 25-26 F1: red LED F2: red LED R/T: yellow LED

ts

tv

ts = start-up delay fixed 200 ms tv = adjustable tripping delay

<tv

<tv

2CDC 252 007 F0207

2CDC 252 006 F0207

Over- and undervoltage monitoring i Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with the correct phase sequence, the output relays energize. The yellow LED R/T glows as long as at least one output relay is energized.
Type of tripping delay = ON-delay If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes after the set tripping delay tV is c omplete. The LED R/T flashes during timing. The corresponding output relay re-energizes automatically as soon as the voltage returns to the tolerance range, taking into a ccount a fixed hysteresis of 5 %.
Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes instantaneously. As soon as the voltage returns to the tolerance range, taking into a ccount a fixed hysteresis of 5 %, the corresponding output relay re-energizes automatically after the set tripping delay tV is complete. The LED R/T flashes during timing.

134

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Three-phase monitoring relays Function diagrams

CM-PAS.xx, CM-MPS.xx, CM-MPN.xx

ON-delay A

L1, L2, L3 Unbalance Unbalance - Hysteresis
Measuring value Unbalance + Hysteresis
Unbalance
15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED

L3

L1, L2, L3 L1, L2

ts

tv

ts = start-up delay fixed 200 ms tv = adjustable tripping delay

<tv

tv

OFF-delay B

L1, L2, L3 Unbalance Unbalance - Hysteresis
Measuring value Unbalance + Hysteresis
Unbalance
15-18 15-16 25-28 25-26
F1: red LED F2: red LED R/T: yellow LED

L3

L1, L2, L3 L1, L2

ts

tv

ts = start-up delay fixed 200 ms tv = adjustable tripping delay

<tv

<tv

2CDC 252 093 F0207

2CDC 252 092 F0207

Phase unbalance monitoring Applying control supply voltage begins the fixed start-up delay tS. When tS is complete and all phases are present with correct voltage and with the correct phase sequence, the output relays energize and the yellow LED R/T glows.
Type of tripping delay = ON-delay If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize after the set tripping delay tV is c omplete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage r eturns to the tolerance range, taking into account a fixed hysteresis of 20% and the LED R/T glows.
Type of tripping delay = OFF-delay If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage r eturns to the tolerance range, taking into account a fixed hysteresis of 20%, the output relays re-energize automatically after the set tripping delay tV is complete. The LED R/T flashes during timing and turns steady when timing is complete.

ERC CATALOG MEASURING AND MONITORING REL AYS

135

-- Three-phase monitoring relays Function diagrams

CM-PSS.xx, CM-PSV.xx, CM-PAS.xx, CM-MPS.xx, CM-MPN.xx

LED functions
Function
Control supply voltage applied, output relay energized Tripping delay tV active Phase failure Phase sequence Overvoltage Undervoltage Phase unbalance Interruption of the neutral Adjustment error

R/T:

F1:

yellow LED red LED

F2: red LED

V-

-

W W

-

-

VW

W alternating

V-

-

V

VV

VW

WW

Possible wrong adjustments of the front-facing operating controls Overlapping of the threshold values: · An overlapping of the threshold values is given if the
threshold value for overvoltage is set to a smaller value than the threshold value for undervoltage. · DIP switch 3 = OFF · DIP switch 4 = ON: Automatic phase sequence correction is activated and selected operating mode is 1x2 c/o contacts · DIP switch 2 and 4 = ON: Phase sequence detection is deactivated and the automatic phase sequence correction is activated

Type of tripping delay The type of tripping delay A / B can be adjusted via a rotary (CM-PxS.xx) or a DIP switch (CM-MPx.xx).
Switch position ON-delay A: In case of a fault, the de-energizing of the output relays and the respective fault message are suppressed for the adjusted tripping delay tV.
Switch position OFF-delay B: In case of a fault, the output relays de-energize instantaneously and a fault message is displayed and stored for the length of the adjusted tripping delay tV. Thereby, also momentary undervoltage conditions are recognized.

136

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

137

-- Grid feeding monitoring relays Table of contents

138

Benefits and advantages

143

Operating controls

144

Selection table

145

Ordering details

146

Technical data

147

Technical diagrams

138

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Grid feeding monitoring relays Benefits and advantages

ABB's grid feeding monitoring relays detect unusual events in the public power grid and keeps it stable by automatically disconnecting and reconnecting the renewable power plant. The CM-UFD displays all relevant measuring data and events and can communicate them via a build-in communication interface. The cloud-based service AbilityTM EDCS enables customers to monitor the conditions in real-time, send the values into the cloud and access the diagnostics remotely.

Optimum interface

Reduce downtime by up to 70% Operate the device via LCD or remotely with the Modbus RTU. Users are informed immediately in case of an event in the public grid. Redundant microcontrollers ensure reliable measuring values and tripping.

Global availability

Cut installation time by up to 60% There's no need to learn every possible adjustment and its effects on your system ­ ABB's trained staff supports your business and answers your technical questions promptly.

Easy installation

Commission & configure up to 60% faster Simple instructions, presets for local grid feeding standards, and ABB's intuitive menu structure make installation quicker. Commissioning and troubleshooting errors are prevented.

ERC CATALOG MEASURING AND MONITORING REL AYS

139

-- Grid feeding monitoring relays Benefits and advantages

ABB's CM-UFD range are multi-functional grid feeding monitoring relays, installed between the renewable energy system and the public grid. The innovative relays guarantee grid stability and prevent blackouts. If the public grid's voltage or frequency moves out of the permitted ranges, the device uses a decoupling unit (e.g. contactor or breaker Tmax XT) to separate the renewable energy system from the public grid. As soon as the grid is stable again, the system is automatically reconnected.
The CM-UFD range provides different monitoring functions in accordance with several local grid feeding standards to detect over-/undervoltage and over-/underfrequency.

Renewable energy system
Modbus RTU
Integration into ABB AbilityTM Electrical Distribution Control System

Decoupling unit

Modbus RTU
Remote PLC for processing & visualization of measurement values

Grid feeding monitoring relay CM-UFD.M*M with Modbus RTU

Public grid

Advantages
· Highly accurate measurement and setting · Modbus RTU communication interface and ABB AbilityTM
EDCS connectivity · Functional safety - single fault tolerances · Clear multiline, backlit LCD · Intuitive and user-friendly menu · Event storage · Pre-settings meet several local standards · Type-tested to a number of local grid feeding
standards by TÜV Süd

Functionality The device measures the ten-minute average value, voltage increases and decreases, as well as any changes in grid frequency. The rate of change of frequency (ROCOF) and vector shift monitoring to detect a loss of mains event can be easily configured.

140

ERC CATALOG MEASURING AND MONITORING REL AYS

--
ABB ABILITYTM EDCS
Monitor your renewable energy plant remotely with ABB´s smart ABB AbilityTM EDCS cloud platform.

ERC CATALOG MEASURING AND MONITORING REL AYS

141

-- Grid feeding monitoring relays Benefits and advantages

The cloud-based service AbilityTM EDCS enables customers to monitor the condition of CM-UFD.M*M in real-time and access the diagnostics remotely. This functionality is very important when operating in the field of critical power. Parametrize with ABB Ekip Connect and access data no matter where you are.

-- Example architecture
Ekip Com Hub

Cloud Platform

ABB Ability TM

ABB Ability TM

Ekip UP Modbus RS-485

CM-UFD
The grid feeding monitoring relays can be connected to the cloud directly by using Ekip Com Hub module. Another option is to connect via Modbus RTU when there is some other device equipped with the Ekip Com Hub like the Emax 2 air-circuit breaker.

In addition to the Ekip Connect 3 software, the following hardware is required: · Ekip UP (min. firmware 2.23) · Ekip Com Hub (min. firmware 1.18) · Ekip Com Modbus RTU (min. firmware 2.28) · Ekip Supply · Ekip T&P cable · CM-UFD.M*M (min. firmware 1.0.1)

For further information regarding integration into ABB AbilityTM EDCS, please use the application note "2CDC112280M0101 CM-UFD.M*M integration into ABB AbilityTM EDCS".

142

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Grid feeding monitoring relays Benefits and advantages

A reliable solution that takes country-specific requirements into account: the range is already pre-set to local requirements, making installation quick and simple. The devices can also be set manually with the display and used all over the world.

Pre-set devices In accordance with a number of local standards, the CM-UFD relays can be used in all low voltage plants and in medium voltage plants.

Type-tested To ensure reliability and compliance, the range is typetested to local standards by the third party authority TÜV Süd.

-- Countries with a dedicated local standard (in red)

Great Britain CM-UFD.M33*

Austria CM-UFD.M31*

France CM-UFD.M31*

Italy CM-UFD.M22M

Germany CM-UFD.M31*

United Arabic Emirates CM-UFD.M34M

-- Countries referring to an existing local standard or using a product with reference to another dedicated standard (in grey)

South Africa CM-UFD.M31* CM-UFD.M22*

Turkey

Poland

CM-UFD.M31*

CM-UFD.M31*

refers to DE standard

Switzerland CM-UFD.M31*

Jordan CM-UFD.M33* refers to GB standard

Australia CM-UFD.M33*

ERC CATALOG MEASURING AND MONITORING REL AYS

143

-- Grid feeding monitoring relays Operating controls

Wide range power supply 24-240 V AC/DC

3 control inputs

Measuring circuits L-L: 0-540 V AC L-N: 0-312 V AC

Indication of operational states U/T: green LED V Control supply voltage applied W Timing F: red LED: Fault message Rx/Tx: yellow LED: Modbus frame reception and transmission

Display

3 output relays

Keypad

ESC: escape / return to previous

menu

<

:

up / value increase

<

:

down / value decrease

OK: enter / confirm selection

Modbus RTU interface

144

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Grid feeding monitoring relays Selection table

CM-UFD.M34M 1SVR560731R3703

CM-UFD.M33M 1SVR560731R3702

CM-UFD.M33 1SVR560730R3402

CM-UFD.M31M 1SVR560731R3701

CM-UFD.M31 1SVR560730R3401

CM-UFD.M22M 1SVR560731R3700

Order number

Type

Rated control supply voltage Us 24-240 V AC/DC Standard CEI 0-21 VDE AR-N 4105, VDE AR-N 4110 ENA G98, G99 DRRG standard of DEWA Rated frequency DC or 50 Hz DC or 50/60 Hz Modbus RTU Suitable for monitoring Single-phase mains Three-phase mains Monitoring function Over-/undervoltage Over-/underfrequency ROCOF (rate of change of frequency) 10 minutes average value Vector shift Thresholds

JJJJJJ
J JJ JJ J
JJJ JJJ
J J JJ
JJJJJJ JJJJJJ
JJJJJJ JJJJJJ JJJJJJ JJJJJJ
JJJJJ
adj adj adj adj adj adj

ERC CATALOG MEASURING AND MONITORING REL AYS

145

-- Grid feeding monitoring relays Ordering details

CM-UFD.M*M

2CDC251003S0017

Description The grid feeding monitoring relays CM-UFD.M*M are designed to monitor the voltage and the frequency of the public low voltage or medium voltage grid. Whenever the measured values are not within the range of the adjusted threshold values, the CM-UFD.M*M causes tripping of the section switch (consisting of 1 or 2 switching devices according to the applicable standard). This tripping disconnects the power generation, such as photovoltaic systems, wind turbines, block-type thermal power stations from the grid.

-- Ordering details

Description

Type

See selection table

CM-UFD.M22M CM-UFD.M31 CM-UFD.M31M CM-UFD.M33 CM-UFD.M33M CM-UFD.M34M

Order code
1SVR560731R3700 1SVR560730R3401 1SVR560731R3701 1SVR560730R3402 1SVR560731R3702 1SVR560731R3703

Weight (1 pc) kg (lb)
0.312 (0.688) 0.304 (0.670) 0.312 (0.688) 0.304 (0.670) 0.312 (0.688) 0.312 (0.688)

146

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Grid feeding monitoring relays Technical data

-- Data sheets For every product of the CM-UFD range, a technical data sheet is available.
· Operating control and mode · Operating principles · Modbus RTU functionality where available · Electrical connection · Configuration and settings · Menu structure · Display and failure messages · Connection and wiring · Technical data · Technical diagrams · CAS system files

-- Ordering data and data sheet numbers

Description

Type CM-UFD.M22M CM-UFD.M31 CM-UFD.M31M CM-UFD.M33 CM-UFD.M33M CM-UFD.M34M

Order code 1SVR560731R3700 1SVR560730R3401 1SVR560731R3701 1SVR560730R3402 1SVR560731R3702 1SVR560731R3703

Data sheet number 2CDC112258D0201 2CDC112208D0201 2CDC112270D0201 2CDC112210D0201 2CDC112271D0201 2CDC112272D0201

For further information regarding integration into ABB AbilityTM EDCS, please use the application note "2CDC112280M0101 CM-UFD.M*M integration into ABB AbilityTM EDCS".

ERC CATALOG MEASURING AND MONITORING REL AYS

147

-- Grid feeding monitoring relays Technical diagrams

2CDC252014F0017 2CDC252015F0017

-- Example of a single-phase application

LN

1

230 V AC

L1 N

CP-E 24/X

11

L+ L-
24 V DC
L+IN L-IN

CP-B 24/X

12

L+OUTL-OUT

24 V DC

4

13

3

L1 N 2

-- Example of a three-phase application

LN

1

230 V AC

L1 N

CP-E 24/X

11

L+ L-

24 V DC
L+IN L-IN

CP-B 24/X

12

4

L+ L- OUT OUT
24 V DC

13

3

5

L1 L2 L3 N 2
5

7

6

8

7

6

8

9

G

10

Legend
1. Control supply voltage for CM-UFD.M*M 2. Public grid 3. Protection fuse for the CM-UFD.M*M 4. Protection fuse for the measuring circuit of the CM-UFD.M*M (optional) 5. Short-circuit protection 6. Undervoltage release 7. Control input for feedback function 8. Switching device of the section switch 9. Switching device of the generator and/or inverter 10. Generator and/or inverter 11. Primary switch mode power supply unit CP-E (230 V AC / 24 V DC) for the buffer module CP-B 12. Ultra-capacitor based buffer module CP-B (24 V DC in/out) 13. Wire protection fuse for the output of the buffer module CP-B

7

6

8

7 6

8

9

G

10

148

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Grid feeding monitoring relays Technical diagrams

-- Load limits curves
V 300
V 200

100 80 60 50 40 30
20

10 0.1 0.2

0.5 1

-- AC load (resistive)

2 4 6 10

I

A

V 300 V 200
100 80 60 50 40 30 20
10 0.1 0.2
-- DC load (resistive)

0.5 1

2 4 6 10

I

A

2CDC252193F0205

2CDC252194F0205
Switching cycles

2CDC252148F0206

1.0 0.9 0.8 F 0.7 0.6
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 
-- Derating factor F at inductive AC load

-- Dimensional drawings in mm and inches
67 2.64"

108 4.25"

2CDC252192F0205

-- Contact lifetime

250 V resistive load
Switching current [A]

90 3.54"
2CDC252008F0013

ERC CATALOG MEASURING AND MONITORING REL AYS

149

150

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

151

-- Insulation monitoring relays for unearthed supply systems Table of contents

152

Benefits and advantages

156

Applications

157

Operating controls

160

Selection table

161

Ordering details

162

Technical data

169

Technical diagrams

152

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Benefits and advantages

The insulation monitoring relays of the CM-IWx range guarantee a continuous insulation monitoring of an IT system. The devices recognize insulation faults as they develop and warn immediately if the value has fallen below the minimum set threshold. This ensures a reliable operation of the system and prevents operational interruption caused by a second, more severe, insulation fault which may lead to a short circuit tripping the main circuit breaker.

24 7
Continuous operation

Keep the system online and reduce downtime with early pre-warnings which enable time for maintenance planning. Monitor voltage free networks for early fault detection. Due to variants with rail and ship approval, the devices have a wide range of applications.

Safety and protection

Safe and reliable detection of insulation faults according to the latest standards is what ABB's insulation monitoring relays deliver. The portfolio extends from standard to more challenging applications and can prevent fire due to fast and reliable earth fault detection. Built-in self-diagnosis and interrupted wire detection further ensure safety.

Easy installation

Read the status of the relay at a glance: clear visualization of the device status via LEDs. Easy to adjust with rotary wheels and variants with push-in terminals make a quick and easy installation and setting possible.

ERC CATALOG MEASURING AND MONITORING REL AYS

153

-- Insulation monitoring relays Benefits and advantages

Overview The CM-IWx product family offers a convincing solution for monitoring ungrounded AC, AC/DC and DC networks according to EN/IEC 61557-8. An IT network is supplied either by an isolating transformer or a voltage source, such as a battery or generator. In these systems, no active conductor is directly connected to earth potential.
The high reliability of an IT system is guaranteed thanks to continuous insulation monitoring. The insulation monitoring device recognizes insulation faults (at least one conductor has a galvanic connection to earth potential) as they develop and immediately reports if the insulation resistance has fallen below a given threshold. Therefore, maintenance activities can be scheduled and executed while the plant keeps running.
Main benefits · Increase plant availability and avoid costly unplanned stops of a plant / machine by quickly detecting faults first · Prevents fires due to detection of a creeping deterioration of the insulation resistance · The adjustment of the setting values is simple and done in a user-friendly way with rotary switches on the front of
the device · Device status is displayed with LEDs that are easy to read and understand · Devices for standard and more challenging applications are available · Variants with rail and ship approvals are available

154

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Benefits and advantages

-- CM-IWS.1 ­ for unearthed pure AC systems
The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 250 V AC and 300 V DC. It can be configured to the requirements of the applications and therefore has multi-functional uses. The device is available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals).

· For monitoring the insulation resistance of unearthed IT systems up to Un = 250 V AC and 300 V DC
· Test function · According to IEC/EN 61557-8 · Rated control supply voltage 24-240 V AC/DC · Prognostic measuring principle with superimposed square
wave signal · One measuring range 1-100 k · 1 c/o (SPDT) contact, closed-circuit principle · Precise adjustment by front-face operating controls in
1 k steps

· Interrupted wire detection · Fault storage / latching configurable by control input · Screw connection or Easy Connect Technology available · Housing material for highest fire protection classification
UL 94 V-0 · Tool-free mounting on DIN rail as well as demounting · 22.5 mm width · 3 LEDs for status indication

-- CM-IWS.2 ­ for unearthed AC, DC or mixed AC/DC systems
The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems with a voltage up to 400 V AC. The CM-IWS.2 can be configured to the requirements of the applications and therefore has multi-functional uses. The device is available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals).

· For monitoring the insulation resistance of unearthed IT systems up to Un = 400 V AC
· Test function · According to IEC/EN 61557-8 · Rated control supply voltage 24­240 V AC/DC · Measuring principle with superimposed DC voltage · One measuring range 1-100 k · Fault storage / latching configurable by control input · Precise adjustment by front-face operating controls in 1 k
steps

· Screw connection or Easy Connect Technology available · Housing material for highest fire protection classification
UL 94 V-0 · Tool-free mounting on DIN rail as well as demounting · 1 c/o (SPDT) contact, closed-circuit principle · 22.5 mm width · 3 LEDs for status indication

ERC CATALOG MEASURING AND MONITORING REL AYS

155

-- Insulation monitoring relays Benefits and advantages

-- CM-IWN.1 ­ for unearthed AC, DC or mixed AC/DC systems
The CM-IWN.1 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or unearthed IT DC systems with a voltage up to 400 V AC and 600 V DC. The measuring range can be extended up to 690 V AC and 1000 V DC by using the coupling unit CM-IVN. It can be configured to the requirements of the applications and therefore has multifunctional uses. The CM-IWN.1 is available with two different terminal versions. You can choose between the proven screw connection technology (double chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals).

· For monitoring the insulation resistance of unearthed IT systems up to Un= 400 V AC and 600 V DC, expansion to 690 V AC and 1000 V DC with CM-IVN
· Test function · According to IEC/EN 61557-8 · Rated control supply voltage 24-240 V AC/DC · Prognostic measuring principle with superimposed square
wave signal · Two measuring ranges 1-100 k and 2-200 k · Precise adjustment of the measuring value in 1 or 2 kW
steps · One (1 x 2 c/o) or two (2 x 1 c/o) threshold values Ran1/ R1
(warning) and Ran2/R2 (pre-warning) configurable(1)

· Precise adjustment of the threshold values in 1 k steps (R1) and 2 k steps (R2)
· Interrupted wire detection configurable · Non-volatile fault storage configurable · Open- or closed-circuit principle configurable · Screw connection or Easy Connect Technology available · Housing material for highest fire protection classification
UL 94 V-0 · Tool-free mounting on DIN rail as well as demounting · 45 mm width · 3 LEDs for status indication

-- CM-IWM.10 and CM-IWM.11 ­ for unearthed AC, DC or mixed AC/DC systems with up to 1500 V measurement voltage
The insulation monitors CM-IWM.10 and CM-IWM.11 provide the best and up-to-date insulation monitoring of modern IT systems in an optimum and state of-the-art way fulfilling the relevant standards. The devices can be used in the most flexible way for AC, DC and AC/DC systems even with large leakage capacity to earth (PE). The adjustment of the setting values is simple and done in a user-friendly way on two rotary switches on the front of the device. Via LEDs the measured value, device parameters and device status are indicated easy to read.

· Insulation monitoring according to IEC/EN 61557-8 · Detection of symmetric and asymmetric insulation faults · 1 c/o contact each for pre-warning and warning · Measuring circuits can be disconnected via control termi-
nals, e.g. for mains couplings · Pre-warning threshold setting range: 20 k ... 2 M · Warning threshold setting range: 1 k ... 250 k · Open- or closed-circuit principle configurable · Setting the maximum earth leakage capacitance to
shorten the response time

· Simple, clearly arranged adjustment of the device with screwdriver
· LED chain to indicate the current insulation resistance · Display of active measuring circuits · Automatic and manual device self-test · Alarm storage selectable · External test and reset push button can be connected · 90 mm width

156

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Applications

The CM-IWS.x and CM-IWN.x series provide

L1

excellent insulation monitoring for general

L2

purpose supply networks, such as:

L3

N

· Non-earthed AC, DC, AC/DC networks

PE

· UPS systems

· Battery networks

· Hybrid and battery-powered vehicles

· Railway applications

A1

11

S1

S2

S3

CMIWS.2

L

w

14

12

A2

The power source in this case is

the secondary side of an incoming transformer which isolates

M

the system for the application.

3~

Earth fault / insulation resistance monitoring of a 4-wire IT AC system with CM-IWS.2

CM-IWM.x can be additionally used in

L+

special applications, such as:

L-

· Industrial networks with frequency

PE

inverters or direct current drives

· Photovoltaic systems with high system leakage capacitance
· Networks with system voltages up to

L(+ ) L(-)

*) G HM PE KE

1500 V DC or 1100 V AC without requiring a coupling unit · Installation on the AC or DC side of an

11-12/14: AL 21-22/24: VW

CM-IWM.11

inverter

· Networks which require measuring circuit deactivation in case two or more un-

RG T

A1+ A2

earthed networks are coupled

DC

Reset

Test

Power supply

*) G-HM connected: Measuring circuit is off
Example of a DC application with CM-IWM.11

Note: Only one insulation monitor must be connected and active in a network at the same time.

ERC CATALOG MEASURING AND MONITORING REL AYS
-- Insulation monitoring relays Operating controls
-- CM-IWM

157
Front-facing rotary switches to adjust threshold values

Indication of operational state and measured ground fault resistance

Test and reset button

158

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Operating controls

-- CM-IWS

Test and reset button
Configuration and setting Front-face rotary switches for threshold value adjustment: · R.1 for R1 tens figures:
0, 10, 20, 30, 40, 50, 60, 70, 80, 90 k in ten k steps · R.2 for R1 units figures: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 k in one k steps

Indication of operational states U: green LED - control supply voltage F: red LED - fault message R: yellow LED - relay status
Marker label for devices without DIP switches

ERC CATALOG MEASURING AND MONITORING REL AYS

159

-- Insulation monitoring relays Operating controls

-- CM-IWN

Front-face rotary switches to adjust the threshold value: · R1.1 for R1 tens figure:
0, 10, 20, 30, 40, 50, 60, 70, 80, 90 k in ten k steps · R1.2 for R1 units figure: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 k in one k steps · R2.1 for R2 tens figure: 0, 20, 40, 60, 80, 100, 120, 140, 160, 180 k in twenty k steps · R2.2 for R2 units figure: 2, 4, 6, 8, 10, 12, 14, 16, 18, 20 k in two k steps

Test and reset button
Indication of operational states U: green LED ­ control supply voltage F1: red LED ­ fault message F2: yellow LED ­ relay status
DIP switches (see DIP switch functions)

160

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Selection table

CM-IWM.11 1SVR470670R1100

CM-IWM.10 1SVR470670R1000

CM-IWN.1P 1SVR760660R0200

CM-IWN.1S 1SVR750660R0200

CM-IWS.1P 1SVR740660R0100

CM-IWS.1S 1SVR730660R0100

CM-IWS.2P 1SVR740670R0200

CM-IWS.2S 1SVR730670R0200

Order number

Type

Rated control supply voltage Us 24 - 240 V AC/DC 24 V DC Measuring voltages 250 V AC (L-PE) 400 V AC (L-PE) 690 V AC (L-PE) 1000 V AC (L-PE) 300 V DC (L-PE) 600 V DC (L-PE) 690 V DC (L-PE) 1000 V DC (L-PE) Measuring range 1 - 100 k 2 - 200 k 2 - 250 k System leakage capacitance, max. 10 F 20 F 1000 F 3000 F Output 1 c/o 1 x 2 c/o or 2 x 1 c/o 2 c/o Operating principle Open-circuit principle Open- or closed-circuit principle adjustable Test Front-face button or control input Reset Front-face button or control input Fault storage / latching configurable Non volatile storage configurable Interrupted wire detection Threshold values configurable Control input (measuring input deactivation) Connection type Push-in terminals Double-chamber cage connection terminals Screw terminals

JJJJJJ JJ

JJ

JJ

JJ

J J J (1)

(1)

(2)

J (3)

JJ

JJ

J (2)

J J (1)

(1)

J (3)

JJJJJJ JJ JJ

JJJJ JJ J J

JJJJ JJ JJ

JJJJ

JJ

JJ

JJJJJJJJ

JJJJJJJJ JJJJJJ JJJJJJ
JJJJ
11112222
J

JJJ JJJ
JJ

1) With coupling unit CM-IVN screw version

CM-IVN.S: 1SVR750669R9400

push-in version

CM-IVN.P: 1SVR760669R9400

2) Allowed voltage range of the supervised network: 0-760 V AC / 0-1000 V

3) Allowed voltage range of the supervised network: 0-1100 V AC / 0-1500 V DC

ERC CATALOG MEASURING AND MONITORING REL AYS

161

-- Insulation monitoring relays Ordering details

CM-IWS.1 CM-IWS.2 CM-IWN.1 CM-IVN

2CDC 251 017 V0012

2CDC 251 009 V0012

2CDC 252 027 V0012

2CDC 251 020 V0012

Description The CM-IWx serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems, IT AC systems with galvanically connected DC circuits, or IT DC systems. The devices are able to monitor control circuits (single-phase) and main circuits (3-phase).
The CM-IWM.x provides the best and up-to-date insulation monitoring of modern IT supply systems in an optimum and state of-the-art way according to IEC 61558-8 including annex C. The device can be used in the most flexible way for AC, DC and AC/DC systems, even with a large leakage capacity to earth (PE) and under adverse conditions.

-- Ordering details

Type

Rated control supply voltage

Nominal voltage Un of the distribution system to be monitored

System leakage capacitance, max.

Adjustment range of the specified response value Ran (threshold)

Type

Order code

CM-IWS.x 24-240 0-250 V AC / 10 F V AC/DC 0-300 V DC

1-100 k

CM-IWS.1S 1SVR730660R0100 CM-IWS.1P 1SVR740660R0100

0-400 V AC

CM-IWS.2S 1SVR730670R0200

CM-IWS.2P 1SVR740670R0200

CM-IWN.x

0-400 V AC / 20 F 0-600 V DC

1-100 k 2-200 k

CM-IWN.1S 1SVR750660R0200 CM-IWN.1P 1SVR760660R0200

CM-IWM.x 24 V DC

0-690 V AC/DC 1)
0-1000 V AC/DC 2)

1000 F 1-250 k 20 k-2 M
3000 F

CM-IWM.10 1SVR470670R1000 CM-IWM.11 1SVR470670R1100

1) Allowed voltage range of the supervised network: 0-760 V AC / 0-1000 V DC 2) Allowed voltage range of the supervised network: 0-1100 V AC / 0-1500 V DC

Weight (1 pc)
kg (lb) 0.148 (0.326) 0.137 (0.302) 0.141 (0.311) 0.130 (0.287) 0.241 (0.531) 0.217 (0.478) 0.500 (1.1)

Coupling unit
Rated control supply voltage = measuring voltage

Nominal voltage Un of the distribution system to be monitored

Type

Order code

Passive device, no control supply voltage needed

0-690 V AC / 0-1000 V DC

CM-IVN.S 1SVR750669R9400 CM-IVN.P 1SVR760669R9400

S: screw connection P: push-in connection

Weight (1 pc)
kg (lb) 0.179 (0.395) 0.165 (0.364)

162

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical data - CM-IWx

Data at Ta = 25 °C and rated values, unless otherwise indicated

CM-IWS.2

CM-IWS.1

CM-IWN.1

Input circuit - Supply circuit

A1 - A2

Rated control supply voltage Us

24-240 V AC/DC

Rated control supply voltage tolerance

-15...+10 %

Typical current / power consumption

24 V DC 30 mA / 0.7 VA

35 mA / 0.9 VA

55 mA / 1.3 VA

115 V AC 12 mA / 1.4 VA

17 mA / 2.0 VA

20 mA / 2.3 VA

230 V AC 12 mA / 2.8 VA

14 mA / 3.2 VA

15 mA / 3.5 VA

Rated frequency fs

DC or 15-400 Hz

Frequency range AC

13.5-440 Hz

Power failure buffering time

min. 20 ms

Start-up time ts, fixed

min. 10 s

max. 15 s

min. 15 s

Input circuit - Measuring circuit

L, w

L+, L-, w, KE

L+, L-, w, KE

Monitoring function

insulation resistance monitoring of IT systems

Measuring principle

superimposed DC voltage prognostic measuring principle with superimposed square wave signal

Nominal voltage Un of the distribution system to be monitored 0-400 V AC

0-250 V AC / 0-300 V DC

0-400 V AC / 0-600 V DC

Voltage range of the distribution system to be monitored

0-460 V AC (tolerance +15 %)

0-287.5 V AC / 0-345 V DC (tolerance +15 %)

0-460 V AC / 0-690 V DC (tolerance +15 %)

Rated frequency fN of the distribution system to be monitored 50-60 Hz

DC or 15-400 Hz

DC or 15-400 Hz

System leakage capacitance Ce

max. 10 F

20 F

Tolerance of the rated frequency fN
Extraneous DC voltage Ufg (when connected to an AC system) Number of possible response / threshold values
Adjustment range of the specified response value Ran (threshold)

45-65 Hz max. none
1 min.-max. 1-100 h min.-max. R1 ­ min.-max. R2 ­

Adjustment resolution
Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+45 °C Un = 0-115 % Us = 85-110 %, fN, fs, Ce = 1F

1 kh
R1 1 kh
R2 ­ at 1-10 kW RF  15 %, max. ±0.5 kh
(yellow marked scale)
at 10-100 kW ±6 % RF
at 1-15 kW RF ­

at 15-200 kW ­ RF

Hysteresis related to the threshold value

25 %; min. 2 kh

Internal impedance Zi

at 50 Hz 135 kh

Internal DC resistance Ri

185 kh

Measuring voltage Um

15 V

Tolerance of measuring voltage Um

+10 %

Measuring current Im

max. 0.1 mA

Response time tan

pure AC system

0.5 x Ran and Ce = 1 F max. 10 s

DC system or AC system with connected

­

rectifiers

Repeat accuracy (constant parameters)

< 0.1 % of full scale

Accuracy of Ra (measured value) within the rated control supply < 0.05 % of full scale voltage tolerance

Accuracy of Ra (measured value) within the operation temperature range

at 1-10 kh RF 5 W / K at 10-100 kh RF 0.05 % / K at 10-200 kh RF ­

Transient overvoltage protection (w - terminal)

Z-diode

13.5-440 Hz 290 V DC
100 kh 115 kh 22 V 0.3 mA max. 15 s
avalanche diode

13.5-440 Hz 460 V DC 2 ­ 1-100 kh 2-200 kh (activated / deactivated by DIP-switch)
1 kh 2 kh  15 %, max. ± 1 kh, with CM-IVN ± 1.5 kh ­ ± 1 kh, with CM-IVN ± 1.5 kh ±8 %
155 kh 185 kh 24 V
0.15 mA
­ 0.05 % / K

ERC CATALOG MEASURING AND MONITORING REL AYS

163

-- Insulation monitoring relays Technical data - CM-IWx

CM-IWS.2

CM-IWS.1

CM-IWN.1

Input circuit - Control circuits

S1 - S2 - S3

Control inputs - volt free

S1-S3 remote test

S2-S3 remote reset

Maximum switching current in the control circuit

1 mA

Maximum cable length to the control inputs

50 m - 100 pF/m [164 ft - 30.5 pF/ft]

Minimum control pulse length

150 ms

No-load voltage at the control input

 24 V ± 5 %

 24 V DC

Indication of operational states

Control supply voltage

LED U (green)

Fault message

LED F (red)

Relay status

LED R (yellow)

Output circuits

Kind of output

relay, 1 c/o (SPDT) contact

2 x 1 or 1 x 2 c/o (SPDT) contacts configurable

Operating principle

closed-circuit principle1)

open- or closed circuit principle configurable1)

Contact material

AgNi alloy, Cd free

Min. switching voltage / Min. switching current

24 V / 10 mA

Max. switching voltage / Max. switching current

see data sheet

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A
DC-12 (resistive) at 24 V 4 A

DC-13 (inductive) at 24 V 2 A

AC rating (UL 508)

Utilization category B 300, pilot duty general purpose 250 V, 4 A, cos  0.75 (Control Circuit Rating Code)

max. rated operational voltage 250 V AC

max. continuous thermal current 4 A at B 300

max. making/breaking apparent 3600/360 VA power at B 300

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

Conventional thermal current Ith

4 A

General data

Duty cycle

100 %

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

vertical not necessary

horizontal 10 mm (0.39 in) at Un > 240 V

not necessary

10 mm (0.39 in) at Un > 400 V

Material of housing

UL 94 V-0

Degree of protection

housing / terminal IP50 / IP20

Electrical connection

Screw connection technology

Easy Connect Technology (Push-in)

Wire size

fine-strand with(out) 1 x 0.5-2.5 mm² (1 x 18-14 AWG) wire end ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG)

2 x 0.5-1.5 mm² (2 x 18-16 AWG)

rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)

2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (5.31-7.08 lb.in)

(1) Closed-circuit principle: Output relay(s) de-energize(s) if a fault is occurring Open-circuit principle: Output relay(s) energize(s) if a fault is occurring

164

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical data - CM-IWx

CM-IWS.2

CM-IWS.1

CM-IWN.1

Environmental data

Ambient temperature ranges operation / storage / transport -25...+60 °C/-40...+85 °C/-40...+85 °C

Climatic class

IEC/EN 60721-3-3 3K5 (no condensation, no ice formation)

Damp heat, cyclic

IEC/EN 60068-2-30 6 x 24 h cycle, 55 °C, 95 % RH

Vibration, sinusoidal

25 Hz: 2.5 g

Isolation data

Rated impulse withstand voltage Uimp

supply / measuring circuit 6 kV supply / output circuit 6 kV

measuring / output circuit 6 kV

output 1 / output circuit 2

4 kV

Rated insulation voltage Ui

supply / measuring circuit 400 V supply / output circuit 300 V

300 V

600 V

supply / measuring circuit 400 V

300 V

600 V

output 1 / output circuit 2 -

-

300 V

Basis insulation

supply / measuring circuit 400 V AC / 300 V DC

250 V AC / 300 V DC

400 V AC / 600 V DC

supply / output circuit 250 V AC / 300 V DC

measuring / output circuit 400 V AC / 300 V DC

250 V AC / 300 V DC

400 V AC / 600 V DC

output 1 / output 2 250 V AC / 300 V DC

Protective separation (IEC/EN 61140)

supply / output circuit 250 V AC / 250 V DC supply / measuring circuit 250 V AC / 250 V DC

measuring / output circuit 250 V AC / 250 V DC

Pollution degree

3

Overvoltage category

III

Standards / Directives

Standards

IEC/EN 60947-5-1, IEC/EN 61557-1, IEC/EN 61557-8

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2, IEC/EN 61326-2-4

electrostatic discharge

IEC/EN 61000-4-2 level 3, 6 kV / 8 kV

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)

electrical fast transient/burst

IEC/EN 61000-4-4 level 3, 2 kV / 5 kHz

surge

IEC/EN 61000-4-5 level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-earth

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3, 10 V

voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-11 class 3

harmonics and interharmonics

IEC/EN 61000-4-13 class 3

Interference emissions

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 class B

high-frequency conducted

IEC/CISPR 22, EN 55022 class B

ERC CATALOG MEASURING AND MONITORING REL AYS

165

-- Insulation monitoring relays Technical data - CM-IVN

CM-IVN

Input circuit - Measuring circuit

VL+, VL-, Vw

Function

expansion of the nominal voltage range of the insulation monitoring relay CM-IWN to 690 V AC or 1000 V DC, max. length of connection cable 40 cm

Measuring principle

see CM-IWN

Nominal voltage Un of the distribution system to be monitored

0-690 V AC / 0-1000 V DC

Voltage range of the distribution system to be monitored

0-793.5 V AC / 0-1150 V DC (tolerance +15 %)

Rated frequency fN of the distribution system to be monitored Tolerance of the rated frequency fN System leakage capacitance Ce Extraneous DC voltage Ufg (when connected to an AC system)

DC or 15-400 Hz 13.5-440 Hz max. identical to that of the insulation monitoring relay used max. 793.5 V DC

Tolerance of the adjusted threshold value / Relative percentage uncertainty A at -5...+ 45 °C, Un = 0-115 %, Us = 85-110 %, fN, fs, Ce = 1 F Internal impedance Zi Internal DC resistance Ri Measuring voltage Um Tolerance of measuring voltage Um Measuring current Im

at 1-15 k RF ±1.5 k at 15-200 k RF ±8 %
at 50 Hz 195 k 200 k 24 V +10 % 0.15 mA

General data

MTBF

on request

Duty cycle

100 %

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

vertical not necessary

Degree of protection

horizontal 10 mm (0.39 in) at Un > 600 V IP50 / IP20

Electrical connection

Wire size

fine-strand with(out) wire 2 x 0.75-2.5 mm² (2 x 18-14 AWG) end ferrule

rigid 2 x 0.5-4 mm² (2 x 20-12 AWG)

Stripping length

7 mm (0.28 In)

Tightening torque

0.6-0.8 Nm (5.31-7.08 lb.In)

Max. length of connection cable to CM-IWN

40 cm

Environmental data

Ambient temperature ranges

operation / storage / transport -25...+60 °C / -40...+85 °C / -40...+85 °C

Climatic category

IEC/EN 60721-3-3 3K5 (no condensation, no ice formation)

Damp heat, cyclic

IEC/EN 60068-2-30 6 x 24 h cycle, 55 °C, 95 % RH

Vibration, sinusoidal

IEC/EN 60255-21-1 Class 2

Shock, half-sine

IEC/EN 60255-21-2 Class 2

Isolation data

Rated impulse withstand voltage Uimp Rated insulation voltage Ui Pollution degree

input circuit / PE 8 kV input circuit / PE 1000 V
3

Overvoltage category

III

Standards / Directives

Standards

IEC/EN 60947-5-1, IEC/EN 61557-1, IEC/EN 61557-8

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

166

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical data - CM-IVN

Electromagnetic compatibility Interference immunity to
electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge
conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted

CM-IVN
IEC/EN 61000-6-2, IEC/EN 61326-2-4 IEC/EN 61000-4-2 level 3, 6 kV / 8 kV IEC/EN 61000-4-3 level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
IEC/EN 61000-4-4 level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 level 3, installation class 3, supply circuit
and measuring circuit 1 kV L-L, 2 kV L-earth IEC/EN 61000-4-6 level 3, 10 V
IEC/EN 61000-4-11 level 3
IEC/EN 61000-4-13 level 3 IEC/EN 61000-6-3
IEC/CISPR 22, EN 50022 class B IEC/CISPR 22, EN 50022 class B

ERC CATALOG MEASURING AND MONITORING REL AYS

167

-- Insulation monitoring relays Technical data - CM-IWM

Input circuit Rated control supply voltage US Voltage range Typical power consumption Measuring circuit Nominal voltage UN Allowed voltage range of the supervised network Frequency range Max. system leakage capacitance Ce Internal resistance (AC/DC) Measuring voltage Max. measured current (RE = 0) Response values RE each adjustable via rotary switches
Response inaccuracy Response value hysteresis
ON delay
Control input Current flow No-load voltage to ground Permissible wire length Min. activation time Output Contacts Thermal current Ith Switching capacity to AC-15
Electrical life Short circuit strength max. fuse rating Mechanical life

CM-IWM.10

CM-IWM.11

24 V DC 20-30 V DC max. 5 W L(+) / L(-) to PE / KE 0-690 V AC/DC 0-760 V AC / 0-1000 V DC DC or 16-1000 Hz 1000 F > 280 k approx. ± 95 V < 0.35 mA

0-1000 V AC/DC 0-1100 V AC / 0-1500 V DC DC or 16-1000 Hz 3000 F

pre-warning ("VW") warning ("AL") 20 k 1 k 30 k 3 k 50 k 10 k 70 k 20 k
100 k 30 k 150 k 50 k 250 k 70 k 500 k 100 k 1000 k 150 k 2000 k 250 k IEC/EN 61557-8 ± 15 % + 1.5 k at range 10 k ... 700 k approx. 25 % out of range: approx. 40 % + 0.5 k at CE = 1 F < 10 s RE of  to 0.5 * response value
between T, R and G approx. 3 mA approx. 12 V < 50 m 0.5 s

between HM, T, R and G

2 x 1 c/o contacts for VW and AL 4 A n/o contact 3 A / AC 230 V acc. to IEC/EN 60947-5-1 n/c contact 1 A / AC 230 V acc. to IEC/EN 60947-5-1 at 8 A, AC 250 V 1 x 104 switching cycles 4 A gL acc. to IEC/EN 60947-5-1 10 x 106 switching cycles

168

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical data - CM-IWM

CM-IWM.10

CM-IWM.11

General Data

Operating mode

continuous operation

Temperature range

operation - 25 ... + 60 °C

- 25 ... + 60 °C (device mounted away from heat generation components) -25 ... +45 °C (device mounted without distance to other devices)

storage - 40 ... + 70 °C

Relative air humidity

93 % at 40 °C

Atmospheric pressure

860-1600 mbar (86-106 kPa)

Altitude

IEC/EN 60664-1 < 4000 m

Clearance and creepage distances

Rated impulse voltage / pollution degree

IEC/EN 60664-1

Measuring ciruit L(+) / L(-) to

auxiliary voltage DC and 8 kV / 2 relay contacts VW, AL

auxiliary voltage DC to 8 kV / 2 relay contacts VW, AL

relay contacts VW to relay contact AL 4 kV / 2

Insulation test voltage, routine test

AC 5 kV; 1 s AC 2.5 kV; 1 s

Technical data

EMC

Electrostatic discharge (ESD)

IEC/EN 61000-4-2 8 kV (air)

HF irradiation

IEC/EN 61000-4-3 80 MHz-2.7 GHz: 10 V/m

Fast transients

IEC/EN 61000-4-4 4 kV

Surge voltages

IEC/EN 61000-4-5 between A1 - A2: 1 kV L(+) - L(-): 2 kV A1, A2 - PE: 4 kV L(+), L(-) - PE: 4 kV control line: 0.5 kV control line and earth: 1 kV

HF-wire guided

IEC/EN 61000-4-6 10 V

Interference suppression

EN 55011 limit value class A when connected to a low voltage public system (Class B, EN 55011) radio interference can be generated. To avoid this, appropriate measures have to be taken

Degree of protection

Housing

IEC/EN 60529 IP 40

Terminals

IEC/EN 60529 IP 20

Housing

thermpolastic with V0 behaviour according to UL subject 94

Vibration resistance

IEC/EN 60068-2-6 10-55 Hz: 0.35 mm 2-13.2 Hz: ± 1 mm 13.2-100 Hz: ± 7 g

Shock resistance

IEC/EN 60068-2-27 10 g / 11 ms, 3 pulses

Climate resistance

IEC/EN 60068-1 25 / 060 / 04

Terminal designation

EN 50005

Connecting capacity

1 x 4 mm2 solid

1 x 2.5 mm2 stranded ferruled (isolated)

2 x 1.5 mm2 stranded ferruled (isolated) DIN 46228-1/-2/-3-4

2 x 2.5 mm2 stranded ferruled (isolated) DIN 46228-1/-2/-3

Stripping length

8 mm

Tightening torque

0.8 Nm

Wire fixing

plus-minus terminal scews M3.5 terminal with wire protection

Mounting

IEC/EN 60715 DIN rail

Dimensions

width x height x depth 90 x 90 x 121 mm

ERC CATALOG MEASURING AND MONITORING REL AYS

169

-- Insulation monitoring relays Technical diagrams

-- LEDs, status information and fault messages

CM-IWN.x

CM-IWS.x

Operational state

LED U LED F (green) (red)

Start-up

W OFF

No fault

V OFF

Prewarning

VW

Insulation fault (below threshold value) V V

KE/w wire interruption

VU

L+/L- wire interruption during system start-up / test function

W / X

T

System leakage capacitance too high / V T invalid measurement result

Internal system fault

(1)

X

Setting fault (2)

WW

Test function

X OFF

No fault after fault storage (3)

V (4)

LED R (yellow) OFF (1) W (1) (1)
(1)
(1)
(1) W (1) X

Operational state

LED U (green)

Start-up

W

No fault

V

Insulation fault (below threshold value) V

Invalid measuring result

V

KE/w wire interruption (only CM-IWS. (1) V

CM-IWS.1: System leakage capacitance too high / invalid measurement result

X

CM-IWS.2: Invalid measurement result V

Internal system fault

OFF

Test function

X

No fault after fault storage (3)

V

LED F (red) OFF OFF V T U
X
T X OFF (4)

LED R (yellow) OFF V OFF OFF OFF
OFF
OFF OFF OFF X

(1) Depending on the configuration. (2) Possible faulty setting: The threshold value for final switch-off is set at a higher value than the threshold value for prewarning (3) The device has triggered after an insulation fault. The fault has been stored and the insulation resistance has returned to a higher value than the threshold value plus hysteresis. (4) Depending on the fault

CM-IWM.x
LED status PWR: green LED ERR: red LED
Active: green LED
LED chain: yellow LED VW +: yellow LED VW -: yellow LED VW + and VW -: yellow LED AL +: red LED AL -: red LED AL + and AL -: red LED

LED V V S U Z Y V V V V

Status Control supply voltage applied Internal device error Connection error L+/LConnection error PE/KE Measuring phase with positive polarity Measuring phase with negative polarity 8 LEDs indicate the current insulating resistance ( 10 k ...  2 M) RE lower than prewarning value to + potential RE lower than prewarning value to - potential AC fault / symmetric fault

V V V

RE lower than warning value to + potential RE lower than warning value to - potential AC fault / symmetric fault

170

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical diagrams

-- Connection diagrams
CM-IWS.2

A1

11

S1

S2

S3

Lw

11

R < w

A1 A2

L

14

12

12 14
w
A2

2CDC 252 102 F0009

A1-A2 S1-S3 S2-S3 L w 11-12/14

Control supply voltage Remote test Remote reset Measuring circuit/input, system connection Measuring circuit/input, earth connections Output relay, closed-circuit principle

CM-IWN.1

A1 11 21 S1 S2 S3

L+ L- KE w 11 21

2CDC 252 104 F0009

R < w

A1 A2 12 14 22 24

12 14 L+ VS V1+ V1-
22 24 L- KE w A2

A1-A2 S1-S3 S2-S3 L+, L­ w, KE VS, V1+, V1 11-12/14 21-22/24

Control supply voltage Remote test Remote reset Measuring circuit/input, system connection Measuring circuit/input, earth connections Connections for the coupling unit (if used) Output relay 1, open- or closed-circuit principle Output relay 2, open- or closed-circuit principle

CM-IWS.1

A1

11

KE

S1

S2

S3

L+ L- KE w

11

R < w

A1 A2 12 14

L+

L-

w

14

12

A2

2CDC 252 103 F0009

A1-A2 Control supply voltage S1-S3 Remote test S2-S3 Remote reset L+, L­ Measuring circuit/input, system connection w, KE Measuring circuit/input, earth connections 1-12/14 Output relay, closed-circuit principle

CM-IVN
VL+
VL-

VL-
VL+

2CDC 252 010 F0013

L- V1-

L+ V1+

L+ V1+ L- V1-
VS VE Vw

VE

Connection to CM-IWN.x - w

VS

Connection to CM-IWN.x - VS

L+

Connection to CM-IWN.x - L+

V1+

Connection to CM-IWN.x - V1+

L-

Connection to CM-IWN.x - L-

V1-

Connection to CM-IWN.x - V1-

VL+

Measuring circuit / Measuring input,

VL-

Connection to the system

Vw

Measuring circuit / Measuring input, Connection to earth

ERC CATALOG MEASURING AND MONITORING REL AYS

171

-- Insulation monitoring relays Technical diagrams

-- Connection diagrams
CM-IWM.10

L (+)

L (-)

11 12 14

21 22 24

Us
GT KE PE G R

L+ LPE KE

12 14 22 24

11

21

A1 +

A2

CM-IWM.11

L (+)

L (-)

11 12 14

21 22 24

Us
G HM G T KE PE G R

L+ LPE KE

12 14 22 24

11

21

A1 +

A2

2CDC252005F0016

2CDC252012F0016

Terminal designation A1+, A2 L(+), L(-) KE, PE G, R
G, T
11-12/14 21-22/24

Signal designation
Control supply voltage
Connection for measuring ciruit
Connection for protective conductor
Control input (manual/auto reset) · G/R not jumpered: manual reset · G/R jumpered: auto reset Control input (External test input) connection for an external device test pushbutton Output relay 1 (warning) Output relay 2 (prewarning)

Terminal designation A1+, A2 L(+), L(-) KE, PE G, R
G, T
G, HM
11-12/14 21-22/24

Signal designation
Control supply voltage
Connection for measuring ciruit
Connection for protective conductor
Control input (manual/auto reset) · G/R not jumpered: manual reset · G/R jumpered: auto reset Control input (External test input) connection for an external device test pushbutton Control input (measuring circuit deactivation) · G/HM not jumpered: measuring circuit
activated · G/HM jumpered: measuring circuit
deactivated Output relay 1 (warning)
Output relay 2 (prewarning)

172

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical diagrams

-- DIP switches

CM-IWN.1

Position

4

3

2

1

ON i u f g

OFF j v e h

2CDC 252 050 F0b09

DIP switch 1 Operating principle of the output relays

ON

OFF (default)

Closed-circuit principle g

Open-circuit principle h

If closed-circuit principle is selected, If open-circuit principle is selected,

the output relays de-energize in case the output relays energize in case a

a fault is occurring. In non-fault

fault is occurring. In non-fault state

state the relays are energized.

the relays are

de-energized.

DIP switch 2 Non-volatile fault storage

Fault storage activated (latching) f If the fault storage function is activated, the output relays remain in tripped position until a reset is done either by the front-face button or by the remote reset connection S2-S3. This function is non-volatile.

Fault storage de-activated (non latching) e If the fault storage function is deactivated, the output relays switch back to their original position as soon as the insulation fault no longer exists.

DIP switch 3 Interrupted wire detection

Interrupted wire detection activated u With this configuration, the CMIWN.1 monitoring relays the wires connected to w and KE for interruptions.

Interrupted wire detection deactivated v With this configuration the interrupted wire detection is de-activated.

DIP switch 4 2 x 1 c/o, 1 x 2 c/o

2 x 1 c/o (SPDT) contact i If operating principle 2 x 1 c/o contact is selected, the output relay R1 (11-12/14) reacts to threshold value R1 (final switch-off) and the output relay R2 (21-22/24) reacts to threshold value R2 (prewarning)

1 x 2 c/o (SPDT) contacts j If operating principle 1 x 2 c/o contacts is selected, both output relays R1 (11-12/14) and R2 (21-22/24) react synchronously to threshold value R1. Settings of the threshold value R2 have no effect on the operation.

ERC CATALOG MEASURING AND MONITORING REL AYS

173

-- Insulation monitoring relays Technical diagrams

2CDC252085F0009, 2CDC 252 088 F0009

-- Wiring diagrams CM-IWS.1
Always connect L+ and L- to different conductors. L+ and L- can be connected to any of the conductors. Un  250 V AC; 300 V DC

A1

11

KE

S1

S2

S3

A1

11

KE

S1

S2

S3

2CDC 252 085 F0009, 2CDC252082F0009

L
N PE
-- 2-wire AC system

L+

L-

w

14

12

A2

A1

11

KE

S1

S2

S3

L1 L2 L3 PE
-- 3-wire AC system

L+

L-

w

14

12

A2

A1

11

KE

S1 S2 S3

2CDC252092F0009, 2CDC252089F0009

PWM

L+

DC

L-

PE

-- 2-wire DC system

L+

L-

w

14

12

A2

A1

11

KE

S1

S2

S3

PWM

L+

DC L-

PWM

L+

L+

M

DC L-

L-

PE

-- 3-wire DC system

L+

L-

w

14

12

A2

2CDC252099F0009, 2CDC252096F0009

L1 L2 L3 N PE
-- 4-wire AC system

L+

L-

w

14

12

A2

2CDC252092F0009, 2CDC252095F0009

174

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical diagrams

2CDC252083F0009, 2CDC252082F0009

-- Wiring diagrams CM-IWS.2 L can be connected to any of the conductors. Un  400 V AC
A1 11 S1 S2 S3

L
N PE
-- 2-wire AC system

L

w

14

12

A2

A1 11 S1 S2 S3

L1 L2 L3 PE
-- 3-wire AC system

L

w

14

12

A2

A1 11 S1 S2 S3

L1 L2 L3 N PE
-- 4-wire AC system

L

w

14

12

A2

2CDC252090F0009, 2CDC252089F0009

2CDC252097F0009, 2CDC252096F0009

ERC CATALOG MEASURING AND MONITORING REL AYS

175

-- Insulation monitoring relays Technical diagrams

-- Wiring diagrams
CM-IWN.1 Always connect L+ and L- to different conductors. L+ and L- can be connected to any of the conductors. Un  400 V AC; 600 V DC (For monitoring of systems with higher voltages, use coupling unit CM-IVN.)

A1 11 21 S1 S2 S3

A1 11 21 S1 S2 S3

2CDC252086F0009, 2CDC252088F0009

2CDC252086F0009, 2CDC252082F0009

L
N PE
-- 2-wire AC system

12 14 L+ VS V1+ V1-
22 24 L- KE w A2
A1 11 21 S1 S2 S3

L1 L2 L3 PE
-- 3-wire AC system

12 14 L+ VS V1+ V1-
22 24 L- KE w A2
A1 11 21 S1 S2 S3

2CDC252093F0009, 2CDC252089F0009

PWM

L+

DC

L-

PE

-- 2-wire DC system

12 14 L+ VS V1+ V1-
22 24 L- KE w A2
A1 11 21 S1 S2 S3

PWM

L+

DC L-

PWM

L+

L+

M

DC L-

L-

PE

-- 3-wire DC system

12 14 L+ VS V1+ V1-
22 24 L- KE w A2

2CDC252093F0009, 2CDC252095F0009

2CDC252100F0009, 2CDC252096F0009

L1 L2 L3 N PE
-- 4-wire AC system

12 14 L+ VS V1+ V1-
22 24 L- KE w A2

176

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical diagrams

2CDC252010F0016

-- Wiring diagrams CM-IWM.10
3 L1 L2 L3 PE

L(+) L(-)

PE KE

CM-IWM.10
-- Example of a AC application

CM-IWM.11

3 L1 L2 L3 PE

L(+) L(-)

*) G HM PE KE

CM-IWM.11
*) G-HM connected: Measuring circuit is off

-- Example of a AC application

2CDC252007F0016

2CDC252011F0016

L+ LPE

L(+ ) L(-)
11-12/14: AL 21-22/24: VW

PE KE
CM-IWM.10

RG T

Reset

Test

-- Example of a DC application

A1+ A2 DC
Power supply

L+ LPE

L(+ ) L(-)

*) G HM PE KE

11-12/14: AL 21-22/24: VW

CM-IWM.11

RG T

Reset

Test

A1+ A2 DC
Power supply

*) G-HM connected: Measuring circuit is off
-- Example of a DC application

2CDC252006F0016

ERC CATALOG MEASURING AND MONITORING REL AYS

177

-- Insulation monitoring relays Technical diagrams

-- Dimensional drawings in mm and inches CM-IWS.x
113.4 4.47" 105.9 4.17"

22.5 0.89"

85.6 3.37"

2CDC252009F0011

-- CM-IWS.x
Accessories

103.7 4.08"

6.5 0.256"

62.5 2.461"
60 2.362" 70 2.756" -- ADP.01  Adapter for screw mounting

10 0.394"
20 0.787"
2CDC252008F0010

11.5 0.453"

22.5 0.89"

8 0.32" 4.8 0.19"

68 2.68"

8 0.315"
2CDC252186F0005

3A11
20 0.787"

front to back 110.5 4.31"

--

--

MAR.01  Marker label for devices without DIP COV.11  Sealable transparent cover

switches

2CDC252010F0011

178

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Insulation monitoring relays Technical diagrams

-- Dimensional drawings in mm and inches CM-IWN.x
114.5 4.51" 107.0 4.21"

45.0 1.77"

85.6 3.37"

2CDC252022F0011

-- CM-IWN.x
Accessories

104.8 4.13"

45 1.772" 35 1.378"
6.5 0.256"

60 2.362" 62.5 2.461"
70 2.756"
-- ADP.02  Adapter for screw mounting

10 0.394"
20 0.787"
2CDC252009F0010

11.5 0.453"

45.0 0.89"

9.3 0.37" 5.75 0.23"

7.85 0.309"
2CDC252020F0011

22.2 0.874"
4T22
19.9 0.783"
-- MAR.12  Marker label for devices with DIP switches

front to back 111.8 4.40"
-- COV.12  Sealable transparent cover

68 2.68" 2CDC252023F0011

ERC CATALOG MEASURING AND MONITORING REL AYS

179

180

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

181

-- Thermistor motor protection relays Table of contents

182

Benefits and advantages

183

Applications

184

Features

186

Offer overview

188

Operating controls

189

Selection table

190

Ordering details

193

Technical data

199

Technical diagrams

182

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Benefits and advantages

The thermistor motor protection relays of the CM-MSx range protect motors with PTC sensors against high temperature. These sensors are incorporated in the motor windings, thus measuring the motor heat directly.

Continuous operation

By using thermistor motor protection relays from ABB, the down and commissioning time can be reduced. The relay is continuously monitoring the sensor circuit to detect short-circuit or interrupted i.e. wire faults, thus contributing to maintenance and time saving in case of faults. In addition, the clear error messages of the front LEDs makes it possible to distinguish between the various fault causes.

Reliable in harsh conditions

Direct motor protection through temperature monitoring of the motor winding offers 100 % motor protection, even under the most difficult ambient conditions. The ABB thermistor motor protection relays give you access to worldwide markets and are approved by local and international standards for many applications such as industry, renewable energies, the marine sector and dangerous and explosive environments. To prove that, the CM-MSS thermistor motor protection relays are certified according to ATEX Ex II (2) G and D for environments with explosive gas or dust loads.

Easy installation

Due to the compliance with the latest standards, there is no need to make any adjustments on the device. All relays come with two different connection possibilities - screw or push-in - to make any adjustments on the installation a breeze. Thanks to direct measurement of the motor temperature, dimensioning of the thermistor motor protection relay, considering the size of the motor, is not necessary.

ERC CATALOG MEASURING AND MONITORING REL AYS

183

-- Thermistor motor protection relays Applications

Direct temperature monitoring Generally, motor damage caused by overload or overheating situations can be prevented in different ways. Compared to the indirect temperature measuring which monitors the motor current, the temperature inside the motor can be measured by direct temperature measuring. This enables direct control and evaluation of different operating conditions: Therefore, the consequences from overheating, such as abrasion as well as electrical failures, can be prevented. The direct measuring principle is carried out by a combination of the thermistor motor protection relay and three PTC sensors which are installed directly in the motor by the manufacturer. Those 3 PTC sensors are placed directly at the thermal hotspots, the motor windings.

Heavy duty starting

Increased switching frequencys
Single phase operation
Phase unbalanced

Operating conditions

High ambient temperature

Insufficient cooling

Breaking operation

Motor protection using current- and temperature-dependent protective devices IEC 60204 stipulates that motors must be protected from overheating at a rating of 0.5 kW and higher. The protection can be provided or executed by overload protection, overtemperature protection or current limiting. For motors with frequent starting and braking, and in environments where cooling may be impaired (e.g. by dust), it is recommended to use the overtemperature protection option in the form of a protective device coordinated with this mode of operation.
On rotor-critical motors, overtemperature detection in the stator windings can lead to delayed and hence inadequate protection. In this case, the standards stipulate additional protection, e.g. by means of an overload relay. This combination of thermistor motor protection and an overload relay is recommended for full motor protection in case of frequent starting and braking of motors, irregular intermittent duty or excessive switching frequency.

Operating mode The thermistor motor protection relays are used to monitor the temperature of motors or generators equipped with PTC sensors type A according to the latest product standard IEC 60947-8. The sensors are built-in into the motor windings, measuring the motor heating. In case of an increase of the temperature in the motor, the resistance of the PTC sensors increases as well. If the motor heats-up excessively (>2.83 k), the output relay(s) de-energize(s) and the corresponding LED displays the overtemperature. A short circuit and an interrupted wire within the sensor circuit can also be detected. A reset is only possible after cooling down of the motor (<1.1 k) or after a wire interruption, or a short circuit within the sensor circuit has been removed. A reset after tripping can be done manually with the Test / Reset button, externally with a push button between S1 and 1T2/2T2, or automatically by jumpering S1-1T2/2T2.

184

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Features

Test function The test function is only possible when there is no fault. By pressing the front-face combined Test / Reset button, a system test routine is executed. If the function ,,Remote Test / Reset" (DIP switch 4) is activated, the system test routine is also possible via control input S1-T2 (S1-1T2/2T2*). After starting the test routine, the output relays de-energize. They remain de-energized until the Test / Reset button is pressed again or control input S1-T2 (S1-1T2/2T2*) is closed (remote reset).

Short-circuit detection x
If a short circuit is detected between the two lines of a sensor circuit, the output relay(s) de-energize(s) and the LEDs will display the specific error code.

Dynamic interrupted wire detection During the operation, the device is permanently monitoring the measuring circuit. If the resistance in the measuring circuit rises, the device distinguishes if there is an overtemperature or an interrupted wire.

Fault storage f, reset function
The fault storage is designed as non-volatile (remanent). This means that after switch-off and return of the control supply voltage the device returns to the state it was prior to the switch-off. If there was no fault prior to the interruption of the control supply voltage, the device restarts automatically after re-applying control supply voltage. If there was a fault prior to the interruption, reset can be reset manually by the Test / Reset button or externally by remote reset between S1-T2 (S1-1T2/2T2*). With deactivated fault storage, reset can be made manually by the Test / Reset button, automatically by jumpering S1-T2 (S1-1T2/2T2*) or externally by remote reset between S1-T2 (S1-1T2/2T2*). Depending on the configuration of DIP switch 1, there are several possibilities to reset the device as shown in the picture.
*CM-MSS.51

DIP switch 1 S1 1T2/2T2

e
1.) Front 2.) Remote 3.) A1-A2

f
1.) Front 2.) Remote

1.) Front S1 1T2/2T2 2.) A1-A2

1.) Front

1.) Auto-

S1 1T2/2T2

Reset

ERC CATALOG MEASURING AND MONITORING REL AYS

185

-- Thermistor motor protection relays Features

Single and accumulative evaluation
Single evaluation i
If a fault occurs in the measuring circuit 1, output relay 1 (11-12/14) de-energizes. If a fault occurs in the measuring circuit 2, output relay 2 (21-22/24) de-energizes.
Accumulative evaluation j
In case of a fault in one of the two measuring circuits, both output relays de-energize synchronously.
Bimetallic switches In some applications, bimetallic switches - such as Klixon - are used as sensors instead of PTC temperature sensors. Bimetallic switches are temperature and current dependent, normally closed contacts, and are available for different temperature ranges. Since bimetallic switches have almost no resistance below their opening temperature, short-circuit detection is not possible when bimetallic switches are used.

I
ATEX certification
Suitably selected and adjusted devices are necessary for the safe operation of explosion-protected motors. Only the sensor line is conducted into the explosive atmosphere. The motor protection relay itself must be installed outside the potentially explosive atmospheres. Marking:
II (2) G
I II (2) D

CM-MSS functionality video

186

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Offer overview

CM-MSE · Auto reset · Connection of several sensors (max. 6 sensors connected
in series) · Monitoring of bimetals · 1 n/o contact · Excellent cost / performance ratio

CM-MSS 1) · Different types of contacts available
- 1 x 2 c/o (SPDT) contacts - 2 x 1 c/o (SPDT) contact - 1 n/o and 1 n/c contact · 1 or 2 measuring circuits · Different types of reset functions - Automatic - Manual - Remote · Rated control supply voltages - 24 V AC/DC - 24-240 V AC/DC - 110-130 V AC, 220-240 V AC · Various approvals and marks

(1) Depending on device the characteristics vary, for detailed overview see "Selection table" on page 189.

ERC CATALOG MEASURING AND MONITORING REL AYS

187

188

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Operating controls

Test / Reset button Test - only possible if/when the relay doesn't show any fault. Reset - only possible if measured value < switch-on resistance
Marker label / DIP switches (depending on device) e.g. i Single evaluation 2 x 1 c/o (SPDT) contact j Accumulative evaluation 1 x 2 c/o (SPDT) contacts y Short-circuit detection de-activated x Short-circuit detection activated f Non-volatile fault storage activated e Non-volatile fault storage de-activated Remote Reset Remote
Reset
Remote Test/Reset Remote
Test/Reset

Indication of operational states with LEDs U: green LED - Status indication of control supply voltage V Control supply voltage applied F: red LED - Fault message R: yellow LED - Status indication of the output relay
For detailed status and failure analysis, please see "LEDs, status information and fault messages".

ERC CATALOG MEASURING AND MONITORING REL AYS

189

-- Thermistor motor protection relays Selection table

CM-MSS.51S 1SVR730712R1300

CM-MSS.51P 1SVR740712R1300

CM-MSS.41S 1SVR730712R1200

CM-MSS.41P 1SVR740712R1200

CM-MSS.33S 1SVR730712R2200

CM-MSS.33P 1SVR740712R2200

CM-MSS.32S 1SVR730712R0200

CM-MSS.32P 1SVR740712R0200

CM-MSS.31S 1SVR730712R1400

CM-MSS.31P 1SVR740712R1400

CM-MSS.23S 1SVR730700R2200

CM-MSS.23P 1SVR740700R2200

CM-MSS.22S 1SVR730700R0200

CM-MSS.22P 1SVR740700R0200

CM-MSS.21S 1SVR730722R1400

CM-MSS.21P 1SVR740722R1400

CM-MSS.13S 1SVR730700R2100

CM-MSS.13P 1SVR740700R2100

CM-MSS.12S 1SVR730700R0100

CM-MSS.12P 1SVR740700R0100

CM-MSS.11S 1SVR730720R1400

CM-MSS.11P 1SVR740720R1400

1SVR550801R9300

1SVR550800R9300

Order code 1SVR550805R9300

CM-MSE

CM-MSE

Type CM-MSE

Characteristics ATEX approval Number of sensor circuits Single or accumulative evaluation Number of LEDs Contacts 1 c/o (SPDT) contact 2 c/o (SPDT) contacts 1 n/o 1 n/c and 1 n/o 2 x 1 c/o or 1 x 2 c/o contacts, configurable Reset Manual Remote Auto Test button Functions Short-circuit detection Short-circuit detection, configurable Dynamic interrupted wire detection Non-volatile fault storage Non-volatile fault storage, configurable Rated control supply voltage Us 24 V AC 110-130 V AC 220-240 V AC 24-240 V AC/DC 24 V AC/DC 110-130 V AC, 220-240 V AC Connection type Push-in terminals Double-chamber cage connection terminals Screw

nn

nn

nnnnnnnnnn

1111111111111111111111122

nn

3322223322223333333333

nnnn

nnnn

nnnnnn

nnn

nn

nn

nn

nn

nnnnnnnnnnnnnn nnnnnnnnnnnnnn n n n n n n n n n n n n n n n n n n n n n n n n n (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (2) (2)
nnnnnnnnnn

nn nn

nn
nn nn

nnnnnn nnnn
nnnnnnnnnn nn
nnnn

n

n

n

nn

nn

nn

nnnn

nn

nn

nn

nn

nn

nn

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

n

nnn

1) For automatic reset, connect terminals S1 to T2. 2) For automatic reset, connect Terminals S1 to 1T2/2T2.

190

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Ordering details

CM-MSS.12S CM-MSS.41S CM-MSS.51S

2CDC 251 014 V0014

2CDC 251 013 V0014

2CDC 251 004 V0014

Description The thermistor motor protection relay CM-MSS monitors the winding temperature and thus protects the motor from overheating, overload and insufficient cooling in accordance to the product standard IEC/EN 60947-8.

-- Ordering details
CM-MSx
Characteristics See selection table
S: screw connection P: push-in connection

Type
CM-MSE CM-MSE CM-MSE CM-MSS.11P CM-MSS.11S CM-MSS.12P CM-MSS.12S CM-MSS.13P CM-MSS.13S CM-MSS.21P CM-MSS.21S CM-MSS.22P CM-MSS.22S CM-MSS.23P CM-MSS.23S CM-MSS.31P CM-MSS.31S CM-MSS.32P CM-MSS.32S CM-MSS.33P CM-MSS.33S CM-MSS.41P CM-MSS.41S CM-MSS.51P CM-MSS.51S

Order code
1SVR550805R9300 1SVR550800R9300 1SVR550801R9300 1SVR740720R1400 1SVR730720R1400 1SVR740700R0100 1SVR730700R0100 1SVR740700R2100 1SVR730700R2100 1SVR740722R1400 1SVR730722R1400 1SVR740700R0200 1SVR730700R0200 1SVR740700R2200 1SVR730700R2200 1SVR740712R1400 1SVR730712R1400 1SVR740712R0200 1SVR730712R0200 1SVR740712R2200 1SVR730712R2200 1SVR740712R1200 1SVR730712R1200 1SVR740712R1300 1SVR730712R1300

Weight (1 pc) kg (lb) 0.11 (0.24) 0.11 (0.24) 0.11 (0.24) 0.119 (0.263) 0.127 (0.280) 0.105 (0.231) 0.113 (0.249) 0.147 (0.324) 0.155 (0.342) 0.118 (0.260) 0.126 (0.278) 0.121 (0.267) 0.132 (0.291) 0.163 (0.359) 0.174 (0.384) 0.120 (0.265) 0.128 (0.282) 0.120 (0.265) 0.130 (0.287) 0.162 (0.357) 0.172 (0.379) 0.130 (0.287) 0.141 (0.311) 0.135 (0.298) 0.145 (0.320)

ERC CATALOG MEASURING AND MONITORING REL AYS

191

-- Thermistor motor protection relays Ordering details - PTC temperature sensors C011

Temperature sensor example

RPTC [] 104
103
102 101

TPTC [°C]

-20 °C TNF - 20 K
TNF - 5 K TNF
TNF + 5 K TNF + 15 K 22CCDDCC25225026806F802F008208

Temperature sensor characteristics

1SVC 110 000 F0531

Description The PTC temperature sensors (temperature-dependent with positive temperature coefficient) are selected by the manufacturer of the motor depending on: · the motor insulation class according to IEC/EN 60034-11, · the special characteristics of the motor, such as the conductor cross-section of the windings,
the permissible overload factor, etc. · special conditions prescribed by the user, such as the permissible ambient temperature, risks
resulting from locked rotor, extent of permitted overload, etc.
One temperature sensor must be embedded in each phase winding. For instance, in case of three-phase squirrel cage motors, three sensors are embedded in the stator windings. For polechanging motors with one winding (Dahlander connection), three sensors are also required. Pole-changing motors with two windings, however, require six sensors. If an additional warning is required before the motor is switched off, separate sensors for a correspondingly lower temperature must be embedded in the winding. They have to be connected to a second control unit. The sensors are suitable for embedding in motor windings with rated operating voltages of up to 600 V AC. Conductor length: 500 mm per sensor. A 14 V varistor can be connected in parallel to protect the sensors from overvoltage. Due to their characteristics, the thermistor motor protection relays can also be used with PTC temperature sensors of other manufacturers which comply with DIN44081 and DIN 44 082.

-- Ordering details

CM-MSS accessories

Rated response temperature TNF

Color coding

Type

70 °C 80 °C

white-brown white-white

C011-701) C011-801)

90 °C

green-green

C011-901)

100 °C

red-red

C011-1001)

110 °C

brown-brown

C011-1101)

120 °C

gray-gray

C011-1201)

130 °C

blue-blue

C011-1301)

140 °C

white-blue

C011-1401)

150 °C

black-black

C011-1501)

160 °C

blue-red

C011-1601)

170 °C

white-green

C011-1701)

150 °C

black-black

C011-3-1502)

1) Temperature sensor C011, standard version acc. to DIN 44081 2) Triple temperature sensor C011-3

Order code
GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0011 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110033R0008

Weight (1 pc) kg (lb) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.02 (0.044) 0.05 (0.11)

192

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Technical data - PTC temperature sensors C011

Characteristic data Cold-state resistance Warm-state resistance ± 5 up to 6 K of rated response temperature TNF Thermal time constant, sensor open1) Permitted ambient temperature

Sensor type C011 50 -100 q at 25 °C 10 000 q < 5 s +180 °C

Rated response temperature PTC resistance R from -20

± tolerance TNF ± TNF

°C to TNF - 20 K

70 w5 °C 80 w5 °C 90 w5 °C 100 w5 °C 110 w5 °C 120 w5 °C 130 w5 °C 140 w5 °C 150 w5 °C 160 w5 °C 170 w7 °C

m 100 q

PTC resistance R2) at PTC temperatures of:

TNF - iTNF (UPTC  2.5 V)

TNF + iTNF (UPTC  2.5 V)

m 570 q

M 570 q

m 550 q

M 1330 q

m 570 q

M 570 q

1) Not embedded in windings. 2) For triple temperature sensor take values x 3.

TNF + 15 K (UPTC  7.5 V) M 4000 q
-

ERC CATALOG MEASURING AND MONITORING REL AYS

193

-- Thermistor motor protection relays Technical data - CM-MSS

Data at Ta = 25 °C and rated values, unless otherwise indicated

Type

CM-MSS.x1

CM-MSS.x2

CM-MSS.x3

Supply circuit - Input circuit

Rated control supply voltage Us

A1-A2 24-240 V AC/DC

24 V AC/DC

220-240 V AC

A2-A3 -

-

110-130 V AC

Rated control supply voltage Us tolerance

-15...+10 %

Rated frequency

15-400 Hz

50-60 Hz

Electrical insulation between supply circuit and measuring circuit yes

no

yes

Power failure buffering time

20 ms

Supply circuit - Measuring circuit / Sensor circuit

Number of circuits

1 (CM-MSS.51: 2)

Sensor type

PTC type A (DIN/EN 44081, DIN/EN 44082)

Max. total resistance of sensors connected in series, cold state

< 750 W

Overtemperature monitoring

switch-off resistance (relay de-energizes) switch-on resistance (relay energizes)

2.83 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 2.7 kW w 5%) 1.1 kW w 1% (CM-MSS.12 /.13 /.22 /.23: 1.2 kW w 5%)

Maximum voltage in sensor circuit

1.33 kW 2.5 V

4 kW 3.7 V

y kW 5.5 V

Maximum current in sensor circuit

3.7 mA

Maximum sensor cable length

2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²

Accuracy within the rated control supply voltage tolerance

0.50 % (CM-MSS.12 /.13 /.22 /.23: 5 %)

Accuracy within the temperature range

0.01 %/K (CM-MSS.12 /.13 /.22 /.23: 0.5 %/K)

Repeat accuracy (constant parameters)

on request

Reaction time of the safety function

< 100 ms

Hardware fault tolerance (HFT)

0

Control circuit

Control function

see "Selection table CM-MSx range"

Maximum no-load voltage

5.5 V

Max. current

0.6 mA (CM-MSS.12 /.13 /.22 /.23: 1.2 mA)

Maximum cable length

2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²

Indication of operational states

Control supply voltage

U LED green

Relay status

R LED yellow

Fault message

F LED red

Output circuit

Kind of output

see "Selection table CM-MSx range"

Operating principle

closed-circuit principle

Contact material

AgNi alloy, Cd free

Rated operational voltage Ue (IEC/EN 60947-1)

250 V AC

Minimum switching voltage / Minimum switching current

24 V / 10 mA

Maximum switching voltage / Maximum switching current

see data sheet

Rated operating current Ie (IEC/EN 60947-5-1)

AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A

DC-12 (resistive) at 24 V 4 A

DC-13 (inductive) at 24 V 2 A

AC Rating (UL 508)

utilization category B 300 (Control Circuit Rating Code)

maximum rated operational voltage 300 V AC

maximum continuous thermal current at B 300 5 A

maximum making/breaking apparent power 3600/360 VA at B 300

general purpose rating 250 V AC - 4 A

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime

at AC12, 230 V AC, 4 A 0.1 x 106 switching cycles

Maximum fuse rating to achieve shortcircuit protection

n/c contact 10 A fast-acting (CM-MSS.12, CM-MSS.13, CM-MSS.51: 6 A) n/o contact 10 A fast-acting

194

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Technical data - CM-MSS

Type

CM-MSS.x1

CM-MSS.x2

CM-MSS.x3

General data

MTBF

on request

Duty time

100 %

Dimensions

see "Dimensional drawings"

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

any

Minimum distance to other units

vertical / horizontal 10 mm (0.394 in) if switching current > 2 A

Material of housing

UL 94 V-0

Degree of protection

housing IP50

terminals IP20

Electrical connection

Screw connection technology

Easy Connect Technology (push-in)

Connection capacity

finestrand with(out) wire end 1 x 0.5-2.5 mm² (1 x 18-14 AWG) ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG)

2 x 0.5-1.5 mm² (2 x 18-16 AWG)

rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)

2 x 0.5-1.5 mm² (2 x 20-16 AWG)

Stripping length

8 mm (0.32 in)

Tightening torque

0.6-0.8 Nm (7.08 lb.in)

-

Environmental data

Ambient temperature ranges

operation -25...+60 °C (-13...+140 °F)

storage -40...+85 °C (-40...+185 °F)

Damp heat, cyclic (IEC/EN 60068-2-30)

6 x 24 h cycle, 55 °C, 95 % RH

Climatic class (IEC/EN 60721-3-3)

3K5 (no condensation, no ice formation)

Vibration, sinusoidal

5-13.2 Hz: ±1 mm; 13.2-100 Hz: 0.7 g

Shock

Class 2

Isolation data

Rated insulation voltage Ui

Supply circuit / Measuring circuit1) 300 V AC (CM-MSS.x2: n/a) Supply circuit / Output circuits 300 V AC

Measuring circuit (1) / Output circuits 300 V AC

Output circuit 1 / Output circuit 2 300 V AC

Rated impulse withstand voltage Uimp

Supply circuit / Measuring circuit1) 4 kV (CM-MSS.x2: n/a) Supply circuit / Output circuits 4 kV

Measuring circuit (1) / Output circuits 4 kV

Output circuit 1 / Output circuit 2 4 kV

Basic insulation

Supply circuit / Measuring circuit1) 600 V AC (CM-MSS.x2: n/a)

Supply circuit / Output circuits 600 V AC

Measuring circuit (1) / Output circuits 600 V AC

Output circuit 1 / Output circuit 2 300 V AC

Protective separation (IEC/EN 61140, EN 50178)

Supply circuit / Measuring circuit1) yes, up to 300 V Supply circuit / Output circuits yes (CM-MSS.x2: n/a)

Measuring circuit (1) / Output circuits yes

Output circuit 1 / Output circuit 2 no

Pollution degree (IEC/EN 60664-1)

3

Overvoltage category (IEC/EN 60664-1)

III

(1) Potential of measuring circuit = Potential of control circuit

Standards Product standard Low Voltage Directive EMC directive ATEX directive RoHS directive

EN 60947-5-1, EN 60947-8 2014/35/EU 2014/30/EU 2014/34/EU (only ATEX variants, see "Selection table CM-MSx range") 2011/65/EU

ERC CATALOG MEASURING AND MONITORING REL AYS

195

-- Thermistor motor protection relays Technical data - CM-MSS

Type

CM-MSS.x1

CM-MSS.x2

CM-MSS.x3

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2, IEC/EN 60947-8

electrostatic discharge

IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz)

electrical fast transient / burst

IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz

surge

IEC/EN 61000-4-5 Level 3, Installation class 3, supply circuit and measuring circuit 1 kV L-L, 2 kV L-N

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz)

voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-11 Class 3

harmonics and interharmonics

IEC/EN 61000-4-13 Class 3

Additional interference immunity according to product standard IEC/EN 60255-1 (reference on IEC/EN 60255-26)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 10 V/m (80 MHz - 3 GHz)

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 10 V at stated frequencies

damped oscillatory waves

IEC/EN 61000-4-18 Signal lines, symmetric coupling: 1 kV peak voltage Power supply, asymmetric coupling: 2.5 kV peak voltage

Interference emissions

IEC/EN 61000-6-3

high-frequency radiated

IEC/CISPR 22, EN 55022 Class B

high-frequency conducted

IEC/CISPR 22, EN 55022 Class B

high-frequency radiated

Germanischer Lloyd increased requirements in the emergency call frequency band

196

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Technical data - CM-MSE

Data at Ta = 25 °C and rated values, unless otherwise indicated

Type

CM-MSE

Supply circuit - Input circuit

Rated control supply voltage Us power consumption

1SVR550805R9300 24 V AC approx. 1.5 A 1SVR550800R9300 110-130 V AC approx. 1.5 A

1SVR550801R9300 220-240 V AC approx. 1.5 A

Rated control supply voltage Us tolerance Rated frequency

-15...+10 % 50-60 Hz

Measuring circuit

Monitoring function

T1-T2 temperature monitoring by means of PTC sensors

Number of sensor circuits

1

Sensor circuit

Sensor type

PTC type A (DIN/EN 44081, DIN/EN 44082)

Max. total resistance of sensors connected in series, cold state

1.0 kW

Overtemperature monitoring

switch-off resistance 2.0-3.0 kW (relay de-energizes)

switch-on resistance (relay energizes) 1.2-1.65 kW

Maximum voltage in sensor circuit

4 kW 5 V

 kW 15 V

Maximum current in sensor circuit

2 mA

Maximum sensor cable length

2 x 100 m at 0.75 mm², 2 x 400 m at 2.5 mm²

Reaction time

<100 ms

Output circuit

Kind of output

13-14 1 n/o contact

Operational principle

closed-circuit principle (output relay de-energizes if the measured value exceeds/drops below the adjusted threshold)

Maximum switching voltage

250 V

Rated operating voltage Ue and rated operating current Ie

AC-12 (resistive) at 230 V 4 A AC-15 (inductive) at 230 V 3 A

DC-12 (resistive) at 24 V 4 A

DC-13 (inductive) at 24 V 2 A

AC Rating (UL 508)

utilization category (Control Circuit Rating Code) B 300

maximum rated operational voltage 300 V AC

maximum continuous thermal current at B 300 5 A

maximum making/breaking apparent power at B 300 3600/360 VA

general purpose rating 250 V AC - 4 A

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime

at AC12, 230 V AC, 4 A 0.1 x 106 switching cycles

Maximum fuse rating to achieve short-circuit protection

n/c contact 10 A fast-acting n/o contact 10 A fast-acting

General data

Dimensions

see "dimensional drawings"

Duty cycle

100 %

Mounting

DIN rail (IEC/EN 60715)

Mounting position

any

Degree of protection

housing / terminals IP50 / IP20

Electrical connection

Connecting capacity

fine strand with wire end ferrule 2 x 1.5 mm² (2 x 16 AWG)

fine strand without wire end ferrule 2 x 0.75-1.5 mm² (2 x 18-16 AWG)

rigid 2 x 1-1.5 mm² (2 x 18-16 AWG)

Stripping length

2 x 0.75-1.5 mm² (2 x 18-16 AWG)

Tightening torque

0.6-0.8 Nm (5.31-7.08 lb.in)

Environmental data

Ambient temperature ranges

Operation -20..+60 °C

Storage -40...+85 °C

Damp heat

IEC/EN 60068-2-30 40 °C, 93 % RH, 4 days

Vibration withstand

IEC/EN 60062-2-6 10-57 Hz: 0.075 mm; 57-150 Hz: 1 g

ERC CATALOG MEASURING AND MONITORING REL AYS

197

-- Thermistor motor protection relays Technical data - CM-MSE

Type Isolation data Rated insulation voltage Ui Rated impulse withstand voltage Uimp Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to
electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient /burst surge
conducted disturbances, induced by radio-frequency fields Interference emission high-frequency radiated high-frequency conducted

CM-MSE
supply, measuring / output circuit 250 V between all isolated circuits 4 kV / 1.2 - 50 s 3 III
IEC/EN 60947-5-1, IEC/EN 60947-8 2014/35/EU 2014/30/EU 2011/65/EU
IEC/EN 61000-6-2, IEC/EN 60947-8 IEC/EN 61000-4-2 Level 3, 6 kV contact discharge, 8 kV air discharge IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz), 3 V/m (2 GHz), 1 V/m (2.7 GHz)
IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz IEC/EN 61000-4-5 Level 3, installation class 3,
supply circuit and measuring circuit 1 kV L-L, 2 kV L-N IEC/EN 61000-4-6 Level 3, 0.15-80 MHz, 10 V, 80 % AM (1kHz)
IEC/EN 61000-6-3 IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B

198

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Technical data

-- LEDs, status information and fault messages

CM-MSS

Operational state Absence of control supply voltage Internal fault2) Internal fault2) Control supply voltage not within the tolerance range Short circuit Interrupted wire Measuring circuit 2: Overtemperature Measuring circuit 1: Overtemperature Fault rectified but not confirmed Test function Change of configuration not confirmed No fault

U: green LED OFF OFF X X V V V V V X V V

1) Depending on the fault with the highest priority 2) Restart the device. If after restart the same fault is indicated, replace the device.

F: red LED OFF W X V Y Z W V - 1) OFF OFF OFF

R: yellow LED OFF W X OFF OFF OFF OFF OFF X OFF X V

ERC CATALOG MEASURING AND MONITORING REL AYS

199

-- Thermistor motor protection relays Technical diagrams

2CDC 252 018 F0014 2CDC 252 022 F0014 2CDC 252 020 F0014 2CDC 252 047 F0014

-- Connection diagrams
CM-MSS.11x, CM-MSS.21x

A1

13

21

T2

T1

T1 A1 14

22



T2 A2 13 21

14

22

A2

A1 ­ A2
13 ­ 14 21 ­ 22 T1 ­ T2

Control supply voltage n/o contact n/c contact Measuring circuit

CM-MSS.12x

A1

11

T2

T1

T1 A1

11



T2 A2

12 14

14

12

A2

A1 ­ A2
11 ­ 12/14 T1 ­ T2

Control supply voltage c/o contact Measuring circuit

CM-MSS.13x

A1

11

A3

T2

T1

T1 A1 A3

11



T2 A2

12 14

CM-MSS.31x

A1

13

21

S1

T2

T1

T1 A1 14

22

S1 

T2 A2 13 21

14

12

A2

A1 ­ A2
A2 ­ A3
11 ­ 12/14 T1 ­ T2

Control supply voltage 220-240 V AC Control supply voltage 110-130 V AC c/o contact
Measuring circuit

14

22

A2

A1 ­ A2
13 ­ 14 21 ­ 22 S1 ­ T2
T1 ­ T2

Control supply voltage n/o contact n/c contact Automatic reset (jumpered) Measuring circuit

2CDC 252 019 F0014 2CDC 252 021 F0014 2CDC 252 017 F0014 1SVC 110 000 F0140

CM-MSS.22x, CM-MSS.32x, CM-MSS.41x

A1

11

21

T2

T1

T1 A1

11

21

S1 

T2 A2 12 14 22 24

24

22

S1

14

12

A2

CM-MSS.23x, CM-MSS.33x

A1

11

21

A3

T2

T1

T1 A1 A3

11

21

S1 

T2 A2

12 14 22 24

24

22

S1

14

12

A2

A1 ­ A2 11 ­ 12/14 21 ­ 22/24 S1 ­ T2 T1 ­ T2

Control supply voltage 24 V AC/DC
1st c/o (SPDT) contact
2nd c/o (SPDT) contact
Automatic reset (jumpered)
Measuring circuit

A1 ­ A2
A2 ­ A3
11 ­ 12/14 21 ­ 22/24 S1 ­ T2 T1 ­ T2

Control supply voltage 220-240 V AC
Control supply voltage 110-130 V AC
1st c/o (SPDT) contact
2nd c/o (SPDT) contact
Automatic reset (jumpered)
Measuring circuit

CM-MSS.51x

CM-MSE

A1

11

21

1T1 1T2/2T2 2T1

1T1 A1

11

2T1 A1

21

S1 

S1 

1T2/2T2 A2 12 14 1T2/2T2 A2 22 24

24

22

S1

14

12

A2

A1 ­ A2

Control supply voltage 220-240 V AC

11 ­ 12/14

1st c/o (SPDT) contact

21 ­ 22/24

2nd c/o (SPDT) contact

S1 ­ 1T2/2T2 Automatic reset (jumpered)

1T1 ­ 1T2/2T2 Measuring circuit 1

2T1 ­ 1T2/2T2 Measuring circuit 2

A1

T1

T2

T1 A1

13



T2 A2

14

13

14

A2

A1 ­ A2
T1-T2 13-14

Control supply voltage 24 V AC
Sensor circuit
Output contact Closed circuit principle

200

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Thermistor motor protection relays Technical diagrams

2CDC 252 025 F0014

-- Circuit diagrams CM-MSS.11x, CM-MSS.21x
V+
A1 14 22

T1

M 3~

µC

T2 t
21 13

A2 V-

CM-MSS.12x
V+ A1
T1 M 3~
T2 t
A2 V-

CM-MSS.13x

V+ 11

A1 or A3 11

T1

M 3~

T2 t

14

14

12

12

A2 V-

2CDC 252 024 F0014

2CDC 252 023 F0014

CM-MSS.22x

CM-MSS.23x

CM-MSS.31x

V+

V+

V+

A1 11
21

A1 or A3 11
21

A1 14
22

T1

T1

T1

M 3~

M 3~

M 3~

µC

T2 t

T2 t

T2 t

24

24

21

22

22

13

Reset

S1 A2

14

Reset

12 S1 A2

14

Reset

12 S1 A2

V-

V-

V-

2CDC 252 027 F0014

2CDC 252 026 F0014

CM-MSS.32x, CM-MSS.41x

CM-MSS.33x

CM-MSS.51x

V+

V+

V+

A1 11
21

A1 or A3 11
21

A1 11
21
1T1

M 3~

M 3~

T1 µC

M 3~

T1 µC

t

1T2/

2T2

µC

2CDC 252 029 F0014

2CDC 252 015 F0014

T2 t

T2 t

24

24

M 3~

24

22

22

2T1

22

Reset

14

Reset

14

t

14

12

12

12

S1

S1

A2

A2

V-

V-

Reset

S1 A2
V-

CM-MSE

2CDC 252 028 F0014

2CDC 252 016 F0014

1SVC 110 000 F0141

ERC CATALOG MEASURING AND MONITORING REL AYS

201

202

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

203

-- Temperature monitoring relays Table of contents

204

Benefits and advantages

205

Applications

207

Operating controls

208

Selection table

209

Ordering details

210

Configuration and setup

212

Technical data

215

Technical diagrams

216

Function diagrams

204

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Temperature monitoring relays Benefits and advantages

The temperature monitoring relays of the CM-TCS range are able to measure temperatures of solids, liquids and gaseous media using PT100 sensors. Overtemperature and undertemperature monitoring, as well as open- or closed-circuit principle is configurable for all devices. As soon as the temperature falls below or exceeds the set threshold value, the output relays change their positions and the front-face LED`s display the current status.

24 7
Continuous operation

By using temperature monitoring relays, both the downtime and the commissioning time can be reduced. The relay is continuously monitoring the sensor circuit to detect short-circuit or interrupted wire faults. The high accuracy of the measuring input leads to a fast detection of exceeding threshold values. In case of fault, maintenance effort is reduced and time saved.

Reliable in harsh conditions
Easy installation

All relays work reliably in environments with low temperatures down to -40 °C. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable no matter the environment temperature but is also durable to shock and vibration. Save time as retightening is no longer needed and enhance the reliability and safety not only for the equipment.
Like all devices from the measuring and monitoring portfolio, the CM-TCS relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. For further configuration options, additional settings can be made via dip-switches, offering the flexibility to configure, for example, the working principle of the relays and the output configuration. The device can be set up before installation in the application and easy adjustments during the process are possible.

ERC CATALOG MEASURING AND MONITORING REL AYS

205

-- Temperature monitoring relays Applications

The temperature monitoring relays CM-TCS monitor overtemperature, undertemperature, or temperatures between two threshold values (window monitoring) with a PT100 sensor.

As soon as the temperature falls below or exceeds the threshold value, the output relays change their positions according to the configured functionality.
The current status is displayed by frontfaced LEDs. Regardless of the selected configuration, the device is monitoring its measuring circuit for interrupted wires or shortcircuits.

Control cabinet temperature monitoring
Air Conditioning and ventilation systems

(Machine) rooms, ball bearings

Application examples

Temperature control of eg. equipment and machines

Refrigiation plants and coolants

206

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Reliable temperature monitoring for critical applications up to -50°C

ERC CATALOG MEASURING AND MONITORING REL AYS

207

-- Temperature monitoring relays Operating controls

Push-in and screw terminals
Measuring input: PT100
Adjustment of the threshold value - 50 ... + 50 °C 0 ... + 100 °C 0 ... + 200 °C

Adjustment of the hysteresis for threshold value 2 - 20 %
Indication of operational states U: green LED ­ status indication of
control supply voltage t: red LED ­ fault message, state of
measuring input R: yellow LED ­ status indication of
the output relays
DIP switch functions / marker label p Overtemperature monitoring q Undertemperature monitoring r Temperature window
monitoring activated s Temperature window
monitoring de-activated g Closed-circuit principle h Open-circuit principle i 2 x 1 c/o (SPDT) contact j 1 x 2 c/o (SPDT) contacts

208

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Temperature monitoring relays Selection table

CM-TCS.13P 1SVR 740 740 R0300

CM-TCS.13S 1SVR 730 740 R0300

CM-TCS.23P 1SVR 740 740 R9300

CM-TCS.23S 1SVR 730 740 R9300

CM-TCS.12P 1SVR 740 740 R0200

CM-TCS.12S 1SVR 730 740 R0200

CM-TCS.22P 1SVR 740 740 R9200

CM-TCS.22S 1SVR 730 740 R9200

CM-TCS.11P 1SVR 740 740 R0100

CM-TCS.11S 1SVR 730 740 R0100

CM-TCS.21P 1SVR 740 740 R9100

CM-TCS.21S 1SVR 730 740 R9100

Order number

Type

Rated control supply voltage Us 24 V AC/DC 24-240 V AC/DC Sensor circuits (2 or 3 wire) Number of temperature sensors Number of thresholds Measuring temperature range -50...+50 °C 0...+100 °C 0...+200 °C Monitoring function Overtemperature Undertemperature Window temperature Operating principle open or closed-circuit principle Output contacts c/o

JJ

JJ

JJ

JJ

JJ

JJ

111111111111 222222222222

JJJJ JJJJ JJJJ

JJJJJJJJJJJJ JJJJJJJJJJJJ JJJJJJJJJJJJ

JJJJJJJJJJJJ

222222222222

ERC CATALOG MEASURING AND MONITORING REL AYS

209

-- Temperature monitoring relays Ordering details

CM-TCS

2CDC 251 031 V0012

Description CM-TCS The temperature monitoring relays CM-TCS are able to measure temperatures of solids, liquids and gaseous media using PT100 sensors. Overtemperature and undertemperature monitoring, as well as open- or closed-circuit principle, is configurable for all devices. As soon as the temperature falls below or exceeds the set threshold value, the output relays change their positions according to the configured functionality and the front-face LEDs display the current status.

-- Ordering details

Temperature monitoring relays CM-TCS

Rated control supply Measuring Temperature Type

voltage

range

sensors

Order code

24-240 V AC/DC 24 V AC/DC

-50...+50 °C PT100 0...+100 °C 0...+200 °C -50...+50 °C 0...+100 °C 0...+200 °C

S: screw connection P: push-in connection

CM-TCS.11S CM-TCS.11P CM-TCS.12S CM-TCS.12P CM-TCS.13S CM-TCS.13P CM-TCS.21S CM-TCS.21P CM-TCS.22S CM-TCS.22P CM-TCS.23S CM-TCS.23P

1SVR730740R0100 1SVR740740R0100 1SVR730740R0200 1SVR740740R0200 1SVR730740R0300 1SVR740740R0300 1SVR730740R9100 1SVR740740R9100 1SVR730740R9200 1SVR740740R9200 1SVR730740R9300 1SVR740740R9300

Weight (1 pc) kg (lb) 0.151 (0.333) 0.140 (0.309) 0.151 (0.333) 0.140 (0.309) 0.151 (0.333) 0.140 (0.309) 0.138 (0.304) 0.127 (0.280) 0.138 (0.304) 0.127 (0.280) 0.138 (0.304) 0.127 (0.280)

210

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Temperature monitoring relays Configuration and setup

-- DIP switches

Position

4

3

2

1

ON i g r p

OFF j h s q

DIP switch 1 Monitoring principle
DIP switch 2 Temperature window monitoring
DIP switch 3 Operating principle of the output relays
DIP switch 4 2 x 1 c/o contact, 1 x 2 c/o contacts

ON
Overtemperature monitoring p If overtemperature monitoring is selected, the CM-TCS recognizes temperatures above the selected threshold and trips the output relay according to the selected operating principle.
Temperature window monitoring activated r If temperature window monitoring is selected, the CMTCS monitors over- and undertemperature. If temperature window monitoring is activated, DIP switch 1 is disabled.
Closed-circuit principle g If closed-circuit principle is selected, the output relays are energized. They de-energize if a fault is occurring.
2 x 1 c/o (SPDT) contact i If operating principle 2 x 1 c/o contact is selected, the output relay R1 (11-12/14) reacts to threshold value t1 and the output relay R2 (21-22/24) reacts to threshold value t2.

OFF (default) Undertemperature monitoring q If undertemperature monitoring is selected, the CMTCS recognizes temperatures below the selected threshold and trips the output relay according to the selected operating principle.
Temperature window monitoring de-activated s Temperature window monitoring is de-selected.
Open-circuit principle h If open-circuit principle is selected, the output relays are deenergized. They energize if a fault is occurring.
1 x 2 c/o (SPDT) contacts j If operating principle 1 x 2 c/o contacts is selected, both output relays R1 (11-12/14) and R2 (21-22/24) react synchronously to one threshold value. Overtemperature monitoring: Settings of the threshold value t2 have no effect on the operation. Undertemperature monitoring: Settings of the threshold values t2 have no effect on the operation.

ERC CATALOG MEASURING AND MONITORING REL AYS

211

-- Temperature monitoring relays Configuration and setup

-- Connection of resistance thermometer sensors
2-wire measurement When using 2-wire temperature sensors, the sensor resistance and the wire resistance are added together. The resulting systematic errors must be taken into account when adjusting the tripping device. A jumper must be connected between the terminals T2 and T3. The following table can be used for PT100 sensors to determine the temperature errors caused by the line length. When using resistance sensors with two-wire connection a bridge must be inserted between terminals T2 and T3.
PT100

3-wire measurement To minimize the influence of the wire resistance, a three-wire connection is usually used. By means of the additional wire, two measuring circuits are created. One of these two circuits is used for reference. This way, the tripping device can calculate and take into account the wire resistance automatically.
PT100

T1

T2 T3

T1

T2 T3

Temperature error (depending on the line length and conductor cross section for PT100 sensors at an ambient temperature of 20 °C, in K)

Line length in m
0 10 25 50 75 100 200 500

Wire size mm²

0.50

0.75

0.0

0.0

1.8

1.2

4.5

3.0

9.0

6.0

13.6

9.0

18.1

12.1

36.3

24.2

91.6

60.8

1 0.0 0.9 2.3 4.5 6.8 9.0 18.1 45.5

1.5 0.0 0.6 1.5 3.0 4.5 6.0 12.1 30.2

Error caused by the line The error resulting from the line resistance amounts to approx. 2.5 Kelvin/Ohm. If the resistance of the line is not known and it is not possible to measure it, the error caused by the line can be estimated using the following table.

212

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Temperature monitoring relays Technical data

Type

CM-TCS.11/12/13

CM-TCS.21/22/23

Input circuit

Rated control supply voltage Us

A1-A2 24-240 V AC/DC

24 V AC/DC

Rated control supply voltage Us tolerance

-15...+10 %

Typical current / power / consumption

24 V DC 33 mA / 0.8 VA

18 mA / 0.45 VA

115 V AC 12.5 mA / 1.5 VA

n/a

230 V AC 13 mA / 2.9 VA

n/a

Rated frequency

AC 15-400 Hz

50/60 Hz

Frequency range

AC 13.5-440 Hz

45-65 Hz

Power failure buffering time

min. 20 ms

Measuring circuit

T1, T2, T3

Sensor type

PT100

Connection of the sensor

2-wire yes, jumper between T2-T3

3-wire yes, use terminal T1, T2, T3

Monitoring function

overtemperature, undertemperature or window monitoring

Threshold values adjustable within the measuring range

CM-TCS.x1 -50...+50 °C CM-TCS.x2 0...+100 °C

CM-TCS.x3 0...+200 °C

Number of possible thresholds

2

Tolerance of the adjusted threshold value

typ. ±5 % of the range end value

Hysteresis related to the threshold value

2-20 % of threshold value, min. 1 °C

Measuring principle

continuous current

Typical current in the sensor circuit

0.8 mA

Maximum current in sensor circuit

0.9 mA

Interrupted wire detection

yes, indicated via LED status

Short-circuit detection

yes, indicated via LED status

Accuracy within the rated control supply voltage tolerance

< 0.2 °C / or < 0.01 %/K

Accuracy within the temperature range

< 0.2 °C / or < 0.01 %/K

Repeat accuracy (constant parameters)

< 0.2 % of full scale

Maximum measuring cycle

320 ms

Output circuit

Kind of output

2 x 1 or 1 x 2 c/o (SPDT) contacts configurable

Operating principle

open- or closed-circuit principle configurable (1)

Contact material

AgNi alloy, Cd free

Minimum switching voltage / Minimum switching current

24 V / 10 mA

Maximum switching voltage / Maximum switching current

see `Load limit curves'

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) 230 V 4 A AC-15 (inductive 230 V 3 A

DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC Rating (UL508)

utilization category B 300 pilot duty; general purpose 250 V, 4 A, cos  0.75

maximum rated operational voltage 250 V AC

maximum continuous thermal current at B 300 4 A

maximum making/breaking apparent 3600/360 VA power at B 300

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Maximum fuse rating to achieve short-circuit protection

n/c contact 6 A fast-acting n/o contact 10 A fast-acting

Conventional thermal current Ith

4 A

(1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value

ERC CATALOG MEASURING AND MONITORING REL AYS

213

-- Temperature monitoring relays Technical data

Type General data Dimensions Mounting Mounting position Degree of protection Ambient temperature range

CM-TCS.11/12/13

CM-TCS.21/22/23

see "dimensional drawings" DIN rail (IEC/EN 60715), snap-on mounting without any tool any enclosure / terminals IP50 / IP20 operation -40...+60 °C storage /transport -40...+85 °C

Electrical connection Wire size
fine-strand without wire end ferrule
fine-strand with wire end ferrule
rigid
Stripping length Tightening torque
Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Environmental data Ambient temperature ranges Climatic class Damp heat, cyclic Vibration, sinusoidal Shock Isolation data Rated impulse withstand voltage Uimp
Rated insulation voltage Ui

Screw connection technology A1, A2, 11, 12, 14, 21, 22, 24 1 x 0.5-2.5 mm² (1 x 20-14 AWG)
2 x 0.5-1.5 mm² (2 x 20-16 AWG) T1, T2, T3 1 x 0.2-2.5 mm² (1 x 24-14 AWG)
2 x 0.2-1.5 mm² (2 x 24-16 AWG) A1, A2, 11, 12, 14, 21, 22, 24 1 x 0.5-2.5 mm² (1 x 20-14 AWG)
2 x 0.5-1.5 mm² (2 x 20-16 AWG) T1, T2, T3 1 x 0.2-2.5 mm² (1 x 24-14 AWG)
2 x 0.2-1.5 mm² (2 x 24-16 AWG)
A1, A2, 11, 12, 14, 21, 22, 24 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG)
T1, T2, T3 1 x 0.2-4 mm² (1 x 24-12 AWG) 2 x 0.2-2.5 mm² (2 x 24-14 AWG)
8 mm (0.32 In) < 0.5 mm² 0.5 Nm (4.43 lb.In)  0.5 mm² 0.6 - 0.8 Nm (5.31 - 7.08 lb.In)

Easy Connect Technology (Push-in) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) connection with lever 2 x 0.2-1.5 mm² (2 x 24-16 AWG) connection with lever 2 x 0.5-1.5 mm² (2 x 20-16 AWG) connection: push-in 2 x 0.2-1.5 mm² (2 x 24-16 AWG) insulated ferrule (DIN 46228-4-E): connection: push-in ferrule (DIN 46228-1-A): < 0.5 mm², connection with lever  0.5 mm², connection: push-in 2 x 0.5-1.5 mm² (2 x 20-16 AWG) connection: push-in 2 x 0.2-1.5 mm² (2 x 24-16 AWG) < 0.5 mm², connection with lever  0.5 mm², connection: push-in
-

IEC/EN 60255-27, IEC/EN 60947-5-1 2014/35/EU 2014/30/EU 2011/65/EU

operation/storage/ transport -40...+60°C/-40...+85°C/-40...+85°C IEC/EN 60721-3-3 3K5 (no condensation, no ice formation)
IEC/EN 600068-2-30 6 x 24 h cycle, 55 °C, 95 % RH Class 2 Class 2

supply circuit / 4 kV

-

measuring circuit

supply circuit / output circuits 4 kV

measuring circuit / 4 kV output circuits

output circuit 1 / 4 kV output circuit 2

supply circuit / 300 V

-

measuring circuit

supply circuit / output circuits 300 V

measuring circuit / 300 V output circuits

output circuit 1 / 300 V output circuit 2

214

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Temperature monitoring relays Technical data

Type Basis insulation
Protective separation (IEC/EN 61140, EN 50178)
Pollution degree Overvoltatge category Electromagnetic compatibility Interference immunity to
electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge
conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics Interference emission high-frequency radiated high-frequency conducted

CM_TCS.11/12/13 supply circuit / 250 V AC / 300 V DC measuring circuit supply circuit / output circuits 250 V AC / 300 V DC measuring circuit / 250 V AC / 300 V DC output circuits output circuit 1 / 250 V AC / 300 V DC output circuit 2 supply circuit / 250 V AC / 250 V DC measuring circuit supply circuit / output circuits 250 V AC / 300 V DC measuring circuit / 250 V AC / 300 V DC output circuits
3 III

CM-TCS.21/22/23 -
250 V AC / 250 V DC 250 V AC / 250 V DC

IEC/EN 61000-6-2 IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) / 3 V/m (2 GHz) / 1 V/m (2.7 GHz)
IEC/EN 61000-4-4 Level 3, 2 KV / 5 kHz IEC/EN 61000-4-5 Level 3, installation class 3, supply circuit and
measuring circuit 1 kV L-L, 2 kV L-earth IEC/EN 61000-4-6 Level 3, 10 V
IEC/EN 61000-4-11 Class 3
IEC/EN 61000-4-13 Class 3 IEC/EN 61000-6-3
IEC/CISPR 22, EN 55022 Class B IEC/CISPR 22, EN 55022 Class B

ERC CATALOG MEASURING AND MONITORING REL AYS

215

-- Temperature monitoring relays Technical diagrams

85,6 33,70"

-- Connection diagram
A 1 11 21 T3 T2 T1
T1 T2 T3 11 21

A1 A2 12 14 22 24

2CDC 252 025 F0010

24 22 14 12 A2

A1 ­ A2
11 ­ 12/14 21 ­ 22/24 T1, T2, T3

Control supply voltage Output relay R1
Output relay R2
Measuring input, connection PT100

-- Dimensional drawing in mm and inches
113,4 44,65" 105,9 41,69"

22,5 0,89"

CM-TCS.xxx

103,7 40,83"

2CDC252009F0011

-- Electrical isolation
CM-TCS.2x
11 12 14

T1

21

T2

22

T3

24

24 V AC/DC A1 A2
Electrical isolation

2CDC 252 019 F0010 2CDC 252 020 F0010

CM-TCS.1x 11 12 14

T1

21

T2

22

T3

24

24-240 V AC/DC A1 A2
Protective separation acc. to IEC/EN 61140; EN 50178

216

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Temperature monitoring relays Function diagrams

A1-A2 Threshold 1
Hysteresis Measured value
Open-circuit principle open 11-14 11-12 21-24 21-22
U: green LED : red LED
R: yellow LED Closed-circuit principle closed
11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED
A1-A2 Threshold 1
Hysteresis
Threshold 2 Hysteresis
Measured value
Open-circuit principle open 11-14 11-12 21-24 21-22
U: green LED : red LED
R: yellow LED Closed-circuit principle closed
11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED
A1-A2 Measured value
Hysteresis Threshold 2
Open-circuit principle open 11-14 11-12 21-24 21-22
U: green LED : red LED
R: yellow LED Closed-circuit principle closed
11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED

2CDC 252 009 F0209

2CDC 252 010 F0209

2CDC 252 008 F0209

Overtemperature monitoring, 1 x 2 c/o contacts j With this configuration, settings via t2 have no influence on the operating function (t2 disabled).
Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t1, the output relays energize. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis, the output relays de-energize.
Closed-circuit principle: The behavior is inverse to the one with open-circuit principle.
Overtemperature monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t2, output relay R2 (prewarning) energizes. If the measured value exceeds the adjusted threshold value t1, output relay R1 (final switch-off) energizes. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis, output relay R1 (final switch-off) de-energizes. If the measured value drops below the adjusted threshold value t2 minus the adjusted hysteresis, output relay R2 (prewarning) de-energizes.
Closed-circuit principle: The behavior is inverse to the one with open-circuit principle.
Undertemperature monitoring, 1 x 2 c/o contacts j With this configuration, settings via t1 have no influence on the operating function (t1 disabled).
Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value drops below the adjusted threshold value t2, the output relays energize. If the measured value exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, the output relays de-energize.
Closed-circuit principle: The behavior is inverse to the one with open-circuit principle.

ERC CATALOG MEASURING AND MONITORING REL AYS

217

-- Temperature monitoring relays Function diagrams

A1-A2
Measured value Hysteresis
Threshold 1
Hysteresis Threshold 2
Open-circuit principle open 11-14 11-12 21-24 21-22
U: green LED : red LED
R: yellow LED Closed-circuit principle closed
11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED
A1-A2
Threshold 1 Hysteresis
Measured value Hysteresis
Threshold 2
Open-circuit principle open 11-14 11-12 21-24 21-22
U: green LED : red LED
R: yellow LED Closed-circuit principle closed
11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED
A1-A2
Threshold 1 Hysteresis
Measured value Hysteresis
Threshold 2
Open-circuit principle open 11-14 11-12 21-24 21-22
U: green LED : red LED
R: yellow LED Closed-circuit principle closed
11-14 11-12 21-24 21-22 U: green LED : red LED R: yellow LED

2CDC 252 013 F0209

2CDC 252 012 F0209

2CDC 252 011 F0209

Undertemperature monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value drops below the adjusted threshold value t1, output relay R1 (prewarning) energizes. If the measured value drops below the adjusted threshold value t2, output relay R2 (final switch-off) energizes. If the measured value exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, output relay R2 (final switch-off) de-energizes. If the measured value exceeds the adjusted threshold value t1 plus the adjusted hysteresis, output relay R1 (prewarning) de-energizes.
Closed-circuit principle: The behavior is inverse to the one with open-circuit principle.
Temperature window monitoring, 1 x 2 c/o contacts j Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t1 or drops below the adjusted threshold value t2, the output relays energize. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis or exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, the output relays de-energize.
Closed-circuit principle: The behavior is inverse to the one with open-circuit principle.
Temperature window monitoring, 2 x 1 c/o contact i Open-circuit principle: If the measured value is correct, the output relays remain de-energized when control supply voltage is applied. If the measured value exceeds the adjusted threshold value t1 or drops below the adjusted threshold value t2, output relay R1 (> t1) or R2 (< t2) respectively energizes. If the measured value drops again below the adjusted threshold value t1 minus the adjusted hysteresis or exceeds again the adjusted threshold value t2 plus the adjusted hysteresis, output relay R1 (>t1) or R2 (<t2) respectively de-energizes.
Closed-circuit principle: The behavior is inverse to the one with open-circuit principle.

218

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

219

-- Liquid level monitoring relays Table of contents

220

Benefits and advantages

222

Applications

226

Operating controls

228

Selection table

229

Ordering details

230

Technical data

236

Function diagrams

237

Technical diagrams

220

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Benefits and advantages

ABB's liquid level monitoring relays are the ideal solution to regulate and control liquid levels and ratios of mixtures of conductive fluids. The assortment includes single- or multifunctional devices which can be used for overflow protection, dry-running protection of pumps, filling and draining applications as well as max. and min. level alarming.

Global availability

The liquid level monitoring relays are designed to provide a wide supply voltage range, making global differences irrelevant. Additionally, the CM-ENS range meets a broad range of standards and requirements. Together with ABB's global support and sales network, using CM-ENS gives customers the confidence of worldwide sourcing ­ no matter where they build, install or operate their equipment.

Reliable in harsh conditions

High immunity against electromagnetic disturbances is ensured due to advanced measuring technology. Additionally, the housing fulfills the UL 94 V-0 flammability standard requirements. Together with the vibration resistant push-in terminals, the relay is not only reliable no matter the environment temperature but is also durable to shock and vibration. Save time as re-tightening is no longer needed and enhance the reliability and safety not only for the equipment.

Improve installation efficiency

Like all devices from the measuring and monitoring portfolio, the CM-ENS relays are easily configurable via front facing potentiometers. Easy threshold configuration without calculation is accomplished by direct reading scales. The device can be set up before installation in the application and easy adjustments during the process are possible.

ERC CATALOG MEASURING AND MONITORING REL AYS

221

-- Liquid level monitoring relays Benefits and advantages

Operating principle
Liquid level control relays CM-ENS are designed to monitor levels of conductive liquids and media and is used, for example, for liquid level control in pump systems. The measuring principle is based on the resistance change sensed by single-pole electrodes. To avoid electrolytic phenomena, an AC current runs across the probes. A selector switch on the front panel allows selection of the required function and the sensitivity range.

Suitability
Suitable for spring water drinking water sea water sewage

acids, bases liquid fertilizers milk, beer, coffee non-concentrated alcohol

Not suitable for chemically pure water fuel oils explosive areas (liquid gas)

ethylene glycol concentrated alcohol paraffin lacquers

Characteristics
CM-ENS.1x · Control of one or two liquid levels (min/max) · Fill or drain function · Adjustable response sensitivity 5-100 k
CM-ENS.2x · Control of one or two liquid levels (min/max) · Fill (UP) or Drain (DOWN), adjustable via front-face
potentiometer · Adjustable response sensitivity 0.1-1000 k
CM-ENS.31 · Control of one or two liquid levels (min/max) · Fill (UP) or Drain (DOWN), adjustable via front-face
potentiometer · Adjustable response sensitivity 0.1-1000 k · Selectable ON- or OFF-delay · 2 c/o (SPDT) contacts

All CM-ENS devices · Devices with wide rated control supply voltage 24-240 V
AC/DC · Cascadable · High EMC immunity · 3 LEDs for the indication of operational states · Screw connection technology or Easy Connect Technology · Housing material for highest fire protection classification
UL 94 V-0 · Tool-free mounting and demounting on DIN rail · 22.5 mm (0.89 in) width

222

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Applications

Liquid level monitoring relays work in conjunction with, for example, suspension electrodes, and can be used either for direct liquid level control or also for cascading devices, as well as operation modes with several electrodes, or control of two liquid levels are possible.

1SVC 110 000 F0478

Suspension electrode

ERC CATALOG MEASURING AND MONITORING REL AYS

223

-- Liquid level monitoring relays Applications

-- Cascading of several devices With the CM-ENS it is possible to use two devices in one tank. This enables the possibility to realize a pre-warning with additional electrodes. In this way, two additional alarm outputs for exceeding or dropping below the normal level can be implemented in addition to the filling levels MAX and MIN. In addition, a reserve pump can be connected to the additional device.

Pump control

Alarm, empty

Device A C MAX MIN

Device B C MAX MIN

Pump control

Reserve pump for filling

Device A C MAX MIN

Device B C MAX MIN

Pump control

Alarm, full

Device A C MAX MIN

Device B C MAX MIN

Alarm

Pump control
Device A C MAX MIN

Reserve pump for draining
Device B C MAX MIN

Reserve pump

Alarm Filling with alarm empty

Reserve pump Filling with reserve pump

Draining with alarm full

Draining with reserve pump

Control pump 2CDC 252 015 F0215
Control pump 2CDC 252 016 F0215
Control pump 2CDC 252 017 F0215
Control pump
2CDC 252 018 F0215

2CDC252013F0015

Operating mode with three electrodes The CM-ENS measures the electrical resistance of the liquid between two immersion electrodes and a reference electrode.
For CM-ENS.1x only: If the relay is connected to the rated control supply voltage, the output relay changes its switching state as soon as the liquid level reaches the MAX-electrode, while the minimum sensor is submerged. The relay returns to the original state as soon as the minimum sensor is no longer in contact with the monitored medium.
For CM-ENS.2x and CM-ENS.31 only: The function fill () or drain () can be selected via a front-face potentiometer. If the fill function is selected, the output relay is energized until the MAX-electrode becomes wet. Then it is de-energized and not re-energized until the MIN-electrode becomes dry. If the drain function is selected, the output relay energizes as soon as the MAX-electrode becomes wet. It remains energized until the liquid level has dropped below the MIN-electrode.

Operation mode with three electrodes

Operation mode with two electrodes If only one level should be controlled, only the MAX-electrode shall be connected at the CM-ENS.

2CDC252073F0004

Operation mode with two electrodes

224

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Applications

-- Control of two liquid levels via liquid level monitoring relay CM-ENS
In combination with suspension electrodes CM-HC or CM-HCT (suitable for drinking water).

Max
10 20
30
1k 10k 4 5 6 7
Min

ERC CATALOG MEASURING AND MONITORING REL AYS

225

-- Liquid level monitoring relays Applications

-- Overflow protection via liquid level monitoring relay CM-ENS
In combination with the compact support CM-KH-3 and 3 bar electrodes CM-SE.

10 20
30
Max
1k 10k 4 5 6 7
Min

226

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Operating controls

-- CM-ENS.1x

Adjustment of the response sensitivity
Marker label
-- CM-ENS.2x
Adjustment of the function Fill Drain
Adjustment of the response sensitivity range Adjustment of the response sensitivity
Marker label

Indication of operational

40

states with LEDs

50 60
70

U: green LED - Status indication of

control supply voltage

V control supply voltage applied

R: yellow LED - Status indication of the

output relays

V energized

MIN/MAX: yellow LED - Status

indication of the electrodes

V MIN and MAX wet

W MIN wet

1k

Indication of operational

10k 4

states with LEDs

5

6

U: green LED - Status indication of

7

control supply voltage

V control supply voltage

applied

R: yellow LED - Status indication of the

output relays

V energized

MIN/MAX: yellow LED - Status

indication of the electrodes

V MIN and MAX wet

W MIN wet

ERC CATALOG MEASURING AND MONITORING REL AYS
-- Liquid level monitoring relays Operating controls

-- CM-ENS.31

Adjustment of the time delay

10 20
30

Adjustment of the function

A ON-delayed Fill

1k

A ON-delayed Drain

10k

4

B OFF-delayed Fill

5

6

B OFF-delayed Drain

7

Adjustment of the response sensitivity range
Adjustment of the response sensitivity

227
Indication of operational states with LEDS U: green LED - Status indication of control supply voltage V control supply voltage applied W time delay is running R: yellow LED - Status indication of the output relays V energized MIN/MAX: yellow LED - Status indication of the electrodes V MIN and MAX wet W MIN wet

Marker label

228

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Selection table

CM-ENS.31P 1SVR 740 850 R0300

CM-ENS.31S 1SVR 730 850 R0300

CM-ENS.23P 1SVR 740 850 R2200

CM-ENS.23S 1SVR 730 850 R2200

CM-ENS.21P 1SVR 740 850 R0200

CM-ENS.21S 1SVR 730 850 R0200

CM-ENS.13P 1SVR 740 850 R2100

CM-ENS.13S 1SVR 730 850 R2100

CM-ENS.11P 1SVR 740 850 R0100

CM-ENS.11S 1SVR 730 850 R0100

CM-ENE MAX 1SVR 550 851 R9400

CM-ENE MAX 1SVR 550 850 R9400

CM-ENE MAX 1SVR 550 855 R9400

CM-ENE MIN 1SVR 550 851 R9500

CM-ENE MIN 1SVR 550 850 R9500

CM-ENE MIN 1SVR 550 855 R9500

Order code

Type

Rated control supply voltage Us 24-240 V AC/DC 24 V AC 110-130 V AC 220-240 V AC Sensor circuit Number of electrodes (including ground reference) Response sensitivity range 0-100 kOhm 5-100 kOhm 0.1-1000 kOhm Monitoring function Dry running protection Overflow protection Liquid level control Operating principle Open-circuit principle Closed-circuit principle Open- or closed-circuit principle Adjustable ON-/OFF-delay 0.1-10 s Output contacts n/o c/o (SPDT) Connection type Push-in terminals Double-chamber cage connection terminals Screw
adj: adjustable sel: selectable

JJ

JJ

JJ

J

J

J

J

JJ

JJ

J

J

JJ

JJ

2222223333333333

JJJJJJ
adj adj adj adj
adj adj adj adj adj adj

JJJ

JJJJJJJJJJ

JJJJJJJJJJJJJ

JJJJJJJJJJJJJ

JJJ

JJJJ

JJJ

sel sel sel sel sel sel

JJ

111111 1111111122

JJJJJ JJJJJ JJJJJJ

ERC CATALOG MEASURING AND MONITORING REL AYS

229

-- Liquid level monitoring relays Ordering details

CM-ENE MIN CM-ENS.3x

1SVR 550 851 F9500

2CDC 251 004 V0015

Description The liquid level monitoring relays CM-ENS and CM-ENE monitors and controls the liquid level and ratios of mixtures of conductive fluids. It is used for filling and draining applications, to protect pumps against dry-running, to protect tanks against overflow, and for signalization of the status of the monitored liquid level.

-- Ordering details
Characteristics

Type

See selection table CM-ENE MIN

CM-ENE MAX

CM-ENS.11S CM-ENS.11P CM-ENS.13S CM-ENS.13P CM-ENS.21S CM-ENS.21P CM-ENS.23S CM-ENS.23P CM-ENS.31S CM-ENS.31P

Order code
1SVR550855R9500 1SVR550850R9500 1SVR550851R9500 1SVR550855R9400 1SVR550850R9400 1SVR550851R9400 1SVR730850R0100 1SVR730850R2100 1SVR740850R0100 1SVR740850R2100 1SVR730850R0200 1SVR740850R0200 1SVR730850R2200 1SVR740850R2200 1SVR730850R0300 1SVR740850R0300

Weight (1 pc) kg (lb) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.15 (0.33) 0.124 (0.273) 0.117 (0.258) 0.153 (0.337) 0.145 (0.320) 0.125 (0.276) 0.117 (0.258) 0.154 (0.340) 0.147 (0.324) 0.143 (0.315) 0.134 (0.295)

230

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Technical data

Type

CM-ENE MIN

Supply circuit

Rated control supply voltage US power consumption

A1-A2 24 V AC, approx. 1.5 VA A1-A2 110-130 V AC, approx. 1.2 VA

A1-A2 220-240 V AC, approx. 1.4 VA

Rated control supply voltage US tolerance

-15...+15 %

Rated frequency

50-60 Hz

Measuring circuit

MIN-C, MAX-C

Monitoring function

dry-running protection

Response sensitivity

0-100 kq, not adjustable

Maximum electrode voltage

30 V AC

Maximum electrode current

1.5 mA

Electrode supply line

max. cable capacity 3 nF

max. cable length 30 m

Timing circuit

Tripping delay

fixed approx. 200 ms

Indication of operational states

Output relay energized

R: yellow LED

Output circuits

13-14

Kind of output

1 n/o contact

Operational principle1)

open-circuit principle1)

Rated operational voltage Ue

(IEC/EN 60947-1) 250 V

Minimum switching voltage / minimum switching current

- / -

Maximum switching voltage

250 V

Rated operational voltage Ue and rated operational current Ie

AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A

DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC rating (UL 508)

Utilization category B 300 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current at B 300 5 A

max. making/breaking apparent power at B 300 3600/360 VA

Mechanical lifetime

30 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.3 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c contact n/o contact 10 A fast-acting

General data

Duty cycle

100 %

Dimensions

see dimensional drawings

Mounting

DIN rail (IEC/EN 60715)

Mounting position

any

Degree of protection

enclosure / terminals IP50 / IP20

Ambient temperature range

operation / storage -20...+60 °C / -40...+85 °C

Electrical connection

Wire size

fine-strand with wire-end ferrule 2 x 0.75-1.5 mm² (2 x 18-16 AWG)

fine-strand without wire-end ferrule 2 x 1-1.5 mm² (2 x 18-16 AWG)

rigid 2 x 0.75-1.5 mm² (2 x 18-16 AWG)

Stripping length

10 mm (0.39 inch)

Tightening torque

0.6-0.8 Nm

CM-ENE MAX overflow protection closed-circuit principle1)

ERC CATALOG MEASURING AND MONITORING REL AYS

231

-- Liquid level monitoring relays Technical data

Type

CM-ENE MIN

Standards / Directives

Standard

IEC/EN 60947-5-1, EN 50178

Low Voltage Directive

2014/35/EU

EMC Directive

2014/35/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

EN 61000-6-2, EN 61000-6-4

Electrostatic discharge

IEC/EN 61000-4-2 level 3 (6 kV / 8 kV)

Radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

Electrical fast transient / burst

IEC/EN 61000-4-4 level 3 (2 kV / 5 kHz)

Surge

IEC/EN 61000-4-5 level 4 (2 kV L-L)

Conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3 (10 V)

Interference emission

high-frequency radiated

IEC/CISPR 22, class B EN 55022

high-frequency conducted

IEC/CISPR 22, class B EN 55022

Environmental data

Ambient temperature ranges

operation/storage -20..+60 °C / -40...+85 °C

Damp heat

IEC/EN 60068-2-30 40 °C, 93 % RH, 4 days

Vibration withstand

IEC/EN 60068-2-6 10-57 Hz: 0.075 mm; 57-150 Hz: 1 g

Isolation data

Rat. insulation volt. betw. supply, measuring & output circuit

250 V

Rated impulse withstand voltage Uimp between all isolated circuits

4 kV / 1.2-50 µs

Pollution category

3

Overvoltage category

III

1) Open-circuit principle: Output relay energizes if the measured value exceeds/drops below the adjusted threshold. Closed-circuit principle: Output relay de-energizes if the measured value exceeds/drops below the adjusted threshold.

CM-ENE MAX

232

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Technical data

Type Supply circuit Rated control supply voltage US

CM-ENS.1x
CM-ENS.11, CM-ENS.21, CM-ENS.31: A1-A2 24-240 V AC/DC CM-ENS.13, CM-ENS.23: A1-A2 220-240 V AC

CM-ENS.2x

CM-ENS.31

Rated control supply voltage US tolerance Rated frequency Frequency range Typical current / power consumption
Power failure buffering time Start-up time ts
Measuring circuit Sensor type Monitoring function Measuring principle Number of electrodes Response sensitivity Maximum electrode voltage Maximum electrode current
Electrode supply line
Max. measuring cycle
Timing circuit Time delay Indication of operational states Control supply voltage Output relay energized

CM-ENS.13, CM-ENS.23: A3-A2 110-130 V AC

-15...+10 %

50-60 Hz

47-63 Hz

24 V AC 25 mA / 0.6 W

25 mA / 0.6 W

25 mA / 0.6 W

110-130 V AC 20 mA / 2.6 VA

20 mA / 2.6 VA

8 mA / 1.1 VA

220-240 V AC 8.5 mA / 2.1 VA

8.5 mA / 2.1 VA

10 mA / 2.4 VA

24-240 V AC/DC 11 mA / 2.6 VA

11 mA / 2.6 VA

11 mA / 2.6 VA

min. 20 ms

Range 5-100 k max. 1.3 s

-

-

Range 0.1-1 k -

max. 900 ms

Range 1-10 k -

max. 900 ms

Range 10-100 k -

max. 1.3 s

Range 100-1000 k -

max. 6.3 s

MAX-MIN-C

electrode

fill or drain

fill or drain, selectable

conductivity measurement

3

adjustable: 5-100 k adjustable: 0.1-1000 k

6 V AC

1 mA

2 mA

max cable max cable max cable max cable max cable max

capacity length

capacity length

capacity cable

length

Range 5-100 k 10 nF

100 m

-

-

-

-

Range 0.1-1 k -

-

200 nF

1000 m

200 nF 1000 m

Range 1-10 k -

-

200 nF

1000 m

200 nF 1000 m

Range 10-100 k -

-

20 nF

100 m

20 nF

100 m

Range 100-1000 k -

-

4 nF

20 m

4 nF

20 m

Range 5-100 k 1000 ms

-

-

Range 0.1-1 k -

700 ms

Range 1-10 k -

700 ms

Range 10-100 k -

1.1 s

Range 100-1000 k -

5 s

-

0.1-30 s, adjustable,

ON- or OFF-delay

U: green LED R: Yellow LED

ERC CATALOG MEASURING AND MONITORING REL AYS

233

-- Liquid level monitoring relays Technical data

Type

CM-ENS.1x

CM-ENS.2x

CM-ENS.31

Electrode / alarm status

MAX/MIN: Yellow LED

Output circuits

Kind of output

1115-1216/1418 relay, 1 c/o (SPDT) contact

relay, 1st c/o (SPDT) contact

2115-2216/2418 -

relay, 2nd c/o (SPDT) contact

Operational principle

open-circuit principle open- or closed-circuit principle (selectable)

Contact material

AgNi alloy, Cd free

Minimum switching voltage / minimum switching current

12 V / 10 mA

Maximum switching voltage / Maximum switching current

see data sheets

Rated operational voltage Ue and rated operational current Ie (IEC/EN 60947-5-1)

AC-12 (resistive) 230 V 4 A AC-15 (inductive) 230 V 3 A

DC-12 (resistive) 24 V 4 A

DC-13 (inductive) 24 V 2 A

AC rating (UL 508)

Utilization category B 300, pilot duty general purpose 250 V, 4 A, cos  0.75 (Control Circuit Rating Code)

max. rated operational voltage 300 V AC

max. continuous thermal current at B 300 5 A

max. making/breaking apparent power at B 300 3600/360 VA

Mechanical lifetime

10 x 106 switching cycles

Electrical lifetime (AC-12, 230 V, 4 A)

0.1 x 106 switching cycles

Max. fuse rating to achieve short-circuit protection

n/c / n/o contact 6 A / 10 A fast-acting

10 A / 10 A fastacting

Conventional thermal current Ith

4 A

234

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Technical data

Type General data MTBF Duty cycle Dimensions Weight Mounting Mounting position Minimum distance to other units Degree of protection Material of housing Electrical connection
Wire size
Stripping length Tightening torque Standards / Directives Standard Low Voltage Directive RoHS Directive EMC Directive Environmental data Ambient temperature ranges
Damp heat, cyclic (IEC/EN 60068-2-30) Climatic category (IEC/EN 60721-3-3) Vibration, sinusoidal (IEC/EN 60255-21-1) Shock (IEC/EN 60255-21-2) Isolation data Rated impulse withstand voltage Uimp
Pollution degree (IEC/EN 60664-1) Overvoltage category (IEC/EN 60664-1) Rated insulation voltage Ui
Basisc insulation

CM-ENS.1x

CM-ENS.2x

CM-ENS.31

on request 100 % see dimensional drawings see ordering details DIN rail (IEC/EN 60715), snap-on mounting without any tool any CM-ENS.x1: not necessary CM-ENS.x3: 10 mm if contact current > 2 A housing / terminals IP50 / IP20 UL 94 V-0

Screw connection technology
finestrand with(out) 1 x 0.5-2.5 mm² (1 x 18-14 AWG) wire end ferrule 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 8 mm (0.32 in) 0.6 - 0.8 Nm (7.08 lb.in)

Easy Connect Technology (push-in) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG)
-

IEC/EN 60255-27, IEC/EN 60947-5-1 2014/35/EU 2014/30/EU 2011/65/EU
operation -25...+60 °C storage -40...+85 °C 6 x 24 h cycle, 55 °C, 95 % RH 3K5 (no condensation, no ice formation) class 2 class 2

supply circuit / 4 kV measuring circuit
supply circuit / 4 kV output circuits
measuring circuit / 4 kV output circuits
output circuit 1 / 4 kV output circuit 2
3
III
supply circuit / 300 V measuring circuit
supply circuit / 300 V output circuits
measuring circuit / 300 V output circuits
output circuit 1 / 300 V output circuit 2
supply circuit / 250 V AC / 300 V DC measuring circuit
supply circuit / 250 V AC / 300 V DC output circuits
measuring circuit / 250 V AC / 300 V DC output circuits
output circuit 1 / 250 V AC / 300 V DC output circuit 2

ERC CATALOG MEASURING AND MONITORING REL AYS

235

-- Liquid level monitoring relays Technical data

Type Protective separation (IEC/EN 61140, EN 50178)
Pollution degree Overvoltage category Electromagnetic compatibility Interference immunity to
electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge
conducted disturbances, induced by radiofrequency fields voltage dips, short interruptions and voltage variations Interference emission high-frequency radiated high-frequency conducted

CM-ENS.1x
supply circuit / 250 V AC / 300 V DC measuring circuit
supply circuit / 250 V AC / 300 V DC output circuits measuring circuit / 250 V AC / 300 V DC output circuits
3 III

CM-ENS.2x

CM-ENS.31

EN 61000-6-1, EN60255-26 IEC/EN 61000-4-2 level 3 (6 kV / 8 kV) IEC/EN 61000-4-3 level 3 (10 V/m)
IEC/EN 61000-4-4 level 3, 2 KV / 5 kHz IEC/EN 61000-4-5 level 3, installation class 3, supply circuit and measuring circuit 1 kV L-L,
2 kV L-earth IEC/EN 61000-4-6 level 3, 10 V
IEC/EN 61000-4-11 class 3
IEC/EN 61000-6-3, IEC/EN 61000-6-4 IEC/CISPR 22, EN 55022 class B IEC/CISPR 22, EN 55022 class B

236

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Function diagrams

2CDC 252 003 F0015

2CDC 252 001 F0015

CM-ENS
A1-A2/A2-A3 Liquid level max.
min.

11-14 11-12 U: green LED R: yellow LED MIN/MAX: yellow LED
Drain: CM-ENS.1x, CM-ENS.2x
A1-A2 Liquid level
max.
min.

A

t

11-14/21-24 11-12/21-22

U/T: green LED

R: yellow LED

MIN/MAX: yellow LED

B
11-14/21-24 11-12/21-22
U/T: green LED
R: yellow LED
MIN/MAX: yellow LED

Drain: CM-ENS.31

t t

CM-ENE MIN
MIN C
A1-A2 13-14
CM-ENE MAX
MIN C
A1-A2 13-14

A1-A2/A2-A3
max.
min. Liquid level
11-14 11-12 U: green LED R: yellow LED MIN/MAX: yellow LED
Fill: CM-ENS.2x

2CDC 252 004 F0015

A1-A2

max.

min.

Liquid level

t

A

t

11-14/21-24 11-12/21-22

U/T: green LED

R: yellow LED

MIN/MAX: yellow LED

t

t

2CDC 252 002 F0015

B

t

11-14/21-24 11-12/21-22

U/T: green LED

R: yellow LED

MIN/MAX: yellow LED

t

t

Fill: CM-ENS.31

1SVC 110 000 F 0151

The liquid level relays CM-ENE MIN and CM-ENE MAX are used to monitor levels of conductive liquids, for example, in pump control systems for dry-running or overflow monitoring. The measuring principle is based on the occurring resistance change when moistening single-pole electrodes. The single-pole electrodes (see also section Accessories) are connected to the terminals C and MIN or MAX. If the supply voltage is applied to A1-A2 and the electrodes are wet, the output relay of the CM-ENE MIN is energized and the output relay of the CM-ENE MAX is de-energized. The output relay of the CM-ENE MIN de-energizes if the electrodes are no longer wet. The output relay of the CM-ENE MAX energizes if the electrodes are no longer wet.

1SVC 110 000 F 0152

ERC CATALOG MEASURING AND MONITORING REL AYS

237

-- Liquid level monitoring relays Technical diagrams

-- Connection diagrams
CM-ENS.11x, CM-ENS.21x
A1 11 C MAX MIN C MAX MIN 11

CM-ENS.13x, CM-ENS.23x
A1 11 A3 C MAX MIN C MAX MIN 11

CM-ENS.31x

A1 1115 C MAX MIN

C MAX MIN

11

21

2CDC 252 006 F0015 2CDC 252 005 F0015 2CDC 252 007 F0015

A1

A2 12 14

14 12 A2

A1­A2 11­12/14 C MAX MIN

Control supply voltage
1 c/o (SPDT) contact
Reference electrode
Maximum level electrode
Minimum level electrode

A1 A3 A2 12 14

14 12 A2

A1­A2
A3-A2
11­12/14 C MAX
MIN

Control supply voltage 220-240 V AC
Control supply voltage 110-130 V AC
1 c/o (SPDT) contact
Reference electrode
Maximum level electrode
Minimum level electrode

12 14 22 24 A1 A3 A2

2428

2125

2226

1418

1216 A2

A1­A2 1115­1216/1418 2125-2226/2428 C MAX MIN

Control supply voltage
1 c/o (SPDT) contact
2nd c/o (SPDT) contact
Reference electrode
Maximum level electrode
Minimum level electrode

CM-ENE MIN

CM-ENE MAX

1SVC 110 000 F 0153 1SVC 110 000 F 0154

A1-A2
C MIN 13-14

Rated control supply voltage
Reference electrode
Minimum level
Output contact -open-circuit principle

A1-A2
C MIN 13-14

Rated control supply voltage
Reference electrode
Maximum level
Output contact -open-circuit principle

238

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Liquid level monitoring relays Technical diagrams

CM-ENS.1x

1SVC 110 000 F0157

Liquid level control - drain
CM-ENS.2x, CM-ENS.31x

CM-ENS.2x, CM-ENS.31x

1SVC 110 000 F0162

1SVC 110 000 F0161

Liquid level control - fill - selected function " " (UP)

Liquid level control - drain - selected function " " (Down)

ERC CATALOG MEASURING AND MONITORING REL AYS

239

-- Liquid level monitoring relays Technical diagrams

22CCDDC 2C52215932F1029035 F0205

-- Load limit curves

CM-S (22.5 mm), CM-E (22.5 mm)

AC load (resistive)
V 300 V 200

100 80 60 50 40 30
20

10 0.1 0.2

0.5 1

2 4 6 10

I

A

Derating factor F for inductive AC load 1.0 0.9 0.8
F 0.7 0.6 0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos 

2C2DCC 2D52C19225F02210592 F0205

22CDCCD25C2 12945 F20210954 F0205

DC load (resistive)
V 300 V 200

100 80 60 50 40 30
20

10 0.1 0.2

0.5 1

2 4 6 10

I

A

Contact lifetime

Switching cycles

250 V resistive load

Switching current [A]

22CCDCD2C52215482 F1024086F0206

-- Dimensional drawing Dimension in mm and inches
113.4 44.65" 105.9 41.69"

22.5 0.89"

85.6 33.70"

2CDC252010F0011

103.7 40.83"
CM-xxS 1SVR730xxxxxx, 1SVR740xxxxxx

240

1SVC 110 000 F0478
2CDC 251 002 F0005 1SVR 450 056 F6000

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

ELECTRONIC RELAYS AND CONTROLS CATALOG MEASURING AND MONITORING REL AYS

241

-- Accessories Table of contents

242

Ordering details

244

Technical diagrams

245

Technical diagrams

242

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Accessories Ordering details

1SVR 450 056 F6000

1SVC 110 000 F0478

Bar electrode Suspension electrode

1SVR 450 056 F6000

1SVC 110 000 F0478

-- Ordering details
Accessories
Description For type

Width in for devices Type mm

Adapter for CM-S

screw

CM-S.S/P

mounting

CM-N CM-N.S/P

Marker label CM-S, CM-N CM-S.S/P CM-N.S/P

CM-S, CM-N

22.5 45

CM-S.S/P CM-N.S/P

Sealable

CM-S

transparent CM-N cover

CM-S.S/P CM-N.S/P

22.5 45
22.5 45

ADP.01

ADP.02

without DIP MAR.01 switches

with DIP switches
with DIP switches

MAR.02
MAR.12
COV.01 COV.02

COV.11 COV.12

Order code
1SVR430029R0100
1SVR440029R0100 1SVR366017R0100
1SVR430043R0000 1SVR730006R0000 1SVR430005R0100 1SVR440005R0100 1SVR730005R0100 1SVR750005R0100

Bar electrodes
Description

Material Type no.

Order code

Compact support for 3 bar electrodes

Distance plate for 3 bar electrodes

-

Counter nut for 1" thread Length: 300 mm
Length: 600 mm
Length: 1000 mm

1.4301 1.4301 1.4301

CM-KH-3

1SVR450056R6000

CM-AH-3

1SVR450056R7000

CM-GM-1 CM-SE-300

1SVR450056R8000 1SVR450056R0000

CM-SE-600 1SVR450056R0100

CM-SE-1000 1SVR450056R0200

Pkg Weight qty (1 pc)
g (oz) 1 18.4 (0.65)
1 36.7 (1.30)
10 0.19 (0.007)
10 0.13 (0.005)
10 0.152 (0.335)
1 5.2 (0.18) 1 7.7
(0.27) 1 4.0 (0.129) 17
(0.247)
Weight (1 pc) kg (lb) 0.06 (0.132)
0.06 (0.132) 0.06 (0.132) 0.08 (0.176)
0.08 (0.176)
0.08 (0.176)

Suspension electrodes
Description

Connec- Material Type

tion

no.

Order code

CM-HE suspension electrode high-alloy steel, material no. 1.4104 (according to EN 10088-1)

Screw 1.4104 CM-HE 1SVR402902R0000

CM-HC suspension electrode high-alloy steel, material no. 1.4104 (according to EN 10088-1)

Crimp

CM-HCT suspension electrode suitable Crimp for drink water high-alloy steel, material no. 1.4301 (according to EN 10088-1)

1.4104 1.4301

CM-HC 1SVR402902R1000 CM-HCT 1SVR402902R2000

Weight (1 pc) kg (lb) 0.074 (0.163)
0.09 (0.198)
0.09 (0.198)

ERC CATALOG MEASURING AND MONITORING REL AYS

243

-- Accessories Ordering details

2CDC 251 002 F0005

2CDC 251 003 F0005

CM-CT
CM-CT with mounted accessories
CM-CT-A mounted on DIN rail

2CDC 251 159 F0b06

2CDC 251 002 F0005

2CDC 251 003 F0005

Plug-in current transformers CM-CT · Without primary conductor though with foot angle, insulating protective cap and bar
fastening screws · Primary / rated current from 50 A to 600 A · Secondary current of 1 A or 5 A · Class 1

-- Ordering details

Rated primary Secondary Burden class Type

current

current

Order code

50 A 75 A 100 A 150 A 200 A 300 A 400 A 500 A 600 A 50 A 75 A 100 A 150 A 200 A 300 A 400 A 500 A 600 A

1 A

1 VA / 1

CM-CT 50/1

1SVR450116R1000

1.5 VA / 1

CM-CT 75/1

1SVR450116R1100

2.5 VA / 1

CM-CT 100/1 1SVR450116R1200

2.5 VA / 1

CM-CT 150/1 1SVR450116R1300

2.5 VA / 1

CM-CT 200/1 1SVR450116R1400

5 VA / 1

CM-CT 300/1 1SVR450117R1100

5 VA / 1

CM-CT 400/1 1SVR450117R1200

5 VA / 1

CM-CT 500/1 1SVR450117R1300

5 VA / 1

CM-CT 600/1 1SVR450117R1400

5 A

1 VA / 1

CM-CT 50/5

1SVR450116R5000

1.5 VA / 1

CM-CT 75/5

1SVR450116R5100

2.5 VA / 1

CM-CT 100/5 1SVR450116R5200

2.5 VA / 1

CM-CT 150/5 1SVR450116R5300

5 VA / 1

CM-CT 200/5 1SVR450116R5400

5 VA / 1

CM-CT 300/5 1SVR450117R5100

5 VA / 1

CM-CT 400/5 1SVR450117R5200

5 VA / 1

CM-CT 500/5 1SVR450117R5300

5 VA / 1

CM-CT 600/5 1SVR450117R5400

Weight (1 pc) g (oz) 0.31 (0.683) 0.31 (0.683) 0.276 (0.608) 0.32 (0.705) 0.222 (0.489) 0.29 (0.639) 0.27 (0.595) 0.29 (0.639) 0.24 (0.529) 0.3 (0.661) 0.31 (0.683) 0.31 (0.683) 0.28 (0.617) 0.29 (0.639) 0.252 (0.556) 0.26 (0.573) 0.208 (0.459) 0.21 (0.463)

Accessories
Description

Type

Snap-on fastener for DIN rail mounting of CM-CT

CM-CT A

Order code 1SVR450118R1000

Weight (1 pc) g (oz) 0.009 (0.02)

2CDC 251 159 F0b06

244

ERC CATALOG MEASURING AND MONITORING REL AYS

-- Accessories Technical diagrams

-- Operating principle / circuit diagram
CM-CT

K/P1

k/S1

L/P2

l/S2

load

2C2DCDCC22552200001F10F2002606

-- Dimensional drawings in mm and inches
22.5 0.89"

8 0.32" 4.8 0.19"

45.0 0.89"

9.3 0.37" 5.75 0.23"

68 2.68"
2CDC252010F0011

68 2.68"

2CDC252023F0011

Sealable cover COV.11
3A11
20 0.787"
MAR.01

8 0.315"
2CDC 252 186 F0005

front to back 110.5 4.31"

Sealable cover COV:12

front to back 111.8 4.40"

ERC CATALOG MEASURING AND MONITORING REL AYS

245

-- Accessories Technical diagrams

-- Dimensional drawings in mm and inches
61 2.36"

48 1.89" 35 1.38"

2CDC2C252D 153C F0b06252 153 F0b06

78,5 3.09" 75,5 2.97" 31 1.22"

k

l

26

CM-CT

K-P1

a b c d e 40 1.57" 60 2.36"

a 10,5 mm b 12,5 mm c 20,5 mm d 25,5 mm e 30,5 mm

0.41 inch 0.49 inch 0.81 inch 1.00 inch 1.20 inch

a

b

c

d

6,5 0.26"

e

30 1.18" 47 1.85" 62 2.40"

11,5 .453"

4,5 .177"

2CDC 252 187 F0005

11,5 .453"

32,5 1.28" 45,0 1.77"
2CDC252001F0009

4,5 .177"

62,5 2.46"

ADP.01

60 2.36"

10 .394" 22,5 .886"

2CDC 252 187 F0005

62,5 2.46"

ADP.02

60 2.36"

246

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

247

-- Power supplies Table of contents

248

Overview

250

Selection table

253

Power supplies for

industrial applications

255

CP-E range

275

CP-T range

289

CP-C.1 range

313

Power supplies for

building applications

314

CP-D range

327

CP-B range buffer modules

339

Redundancy units

349

Electronic protection

devices EPD24

248

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Primary switch mode power supplies Overview

Modern power supply units are a vital component in energy management and automation technology. As your global partner in these areas, ABB pays the utmost attention to the resulting requirements. Innovation is the key to ABB's power supply product program.
-- Power supplies for industrial applications
CP-E range: economy range The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply units can be operated at an ambient temperature of up to +70 °C. The CP-E range 24 V devices over 18 W offer an output/contact for monitoring of the output voltage and remote diagnosis. Optimized for worldwide applications, the CP-E power supplies can be supplied within a wide range of AC or DC voltages. The output voltage is continuously adjustable, ensuring optimal adaptation to the application, e.g. compensating the voltage drop caused by a long line length. For decoupling of parallel connected power supplies below or equal to 56 V, redundancy modules are available in order to achieve true redundancy.

CP-T range: three-phase range The CP-T range of three-phase power supply units perfectly complements ABB's existing power supply offering in terms of design and functionality, giving you more advanced options for your three-phase applications. Solid state output for function monitoring and remote diagnostics is available. The range is to be used in 340 - 575 V AC or 480 - 820 V DC supply systems. Its continuously adjustable output voltage ensures optimal adaptation to the application, e.g. compensating the voltage drop caused by a long line length.

CP-C.1 range: high-performance range The CP-C.1 power supplies are ABB's high-performance and most advanced range. With excellent efficiency, high reliability and innovative functionality, the CP-C.1 range is ready to take on the most demanding industrial applications. These power supplies have a 150 % integrated power reserve and operate at an efficiency of up to 94 %. They are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals, the CP-C.1 power supplies are the preferred choice for professional DC applications. Giving the power to control.

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

249

-- Primary switch mode power supplies Overview

-- Power supplies for industrial applications
CP-B range: short time buffers ABB offers an innovative and completely maintenance- free product range for buffering the 24 V DC supply in case of interrupted mains on the primary side of the switch mode power supply. · Ultra cap based buffer modules for short time UPS systems · Rated input voltage 24 V DC · Rated currents 3 A, 10 A and 20 A · Expandable with CP-B EXT.2 module · LEDs for status indication · Higher than 90% efficiency · Signaling and status outputs · Buffering times at 100 % load current from 13 s to 38 s (depending on device)
-- Power supplies for building applications
CP-D range: distribution panel design The CP-D range of power supply units in MDRC design (modular DIN rail components) fits into all domestic installation and distribution panels. With their width of only 18 to 90 mm, the CP-D range switch mode power supplies are ideally suited for installation in distribution panels. The range is optimized for worldwide applications: The CP-D power supplies can be supplied with 90-264 V AC or 120-375 V DC. The continuously adjustable output voltage (CP-D > 10 W) ensures optimal adaption to the application, e.g. compensating the voltage drop caused by a long line length. An additional redundancy unit CP-RUD to establish true redundancy is available.

For certifications and approvals, please refer to the download section on the product web pages.

250

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Primary switch mode power supplies Selection table - Single-phase

Order number 1SVR427041R1000 1SVR427043R1200 1SVR427041R0000 1SVR427043R0100 1SVR427044R0200 1SVR427045R0400 1SVR427033R3000 1SVR427032R1000 1SVR427035R1000 1SVR427030R0000 1SVR427031R0000 1SVR427032R0000 1SVR427034R0000 1SVR427035R0000 1SVR427036R0000 1SVR427030R2000 1SVR427031R2000 1SVR427034R0000 1SVR427035R2000 1SVR360563R1001 1SVR360663R1001 1SVR360763R1001 1SVR360563R2001 1SVR360663R2001 1SVR360763R2001 1SVR361563R1001 1SVR361663R1001 1SVR361763R1001

Single-phase

CP-D

CP-E

CP-C.1

Rated output voltage

5 V DC 12 V DC N N

N NN

24 V DC

NNNN

NNNN NN

NNNNNNNNN

48 V DC

NN N N

Rated output

0.42 A

N

current

0.625 A

N

0.75 A

N

0.83 A N

1.25 A

N

N

1.3 A

N

2.1 A

N

2.5 A

N

N

N

3 A

N

4.2 A

N

5 A

N

N

N

N

N

10 A

N

N

N

N

N

N

20 A

N

N

N

N

Rated output power

10 W N

N

15 W

N

18 W

N

25 W

N

30 W

N

N

N

N

60 W

N

N

N

100 W

N

120 W

N

N

N

N

N

240 W

N

N

N

N

N

480 W

N

N

N

N

N

Rated input voltage

100-240 V AC N N N N N N N N

NNN

115/230 V AC auto select

N

NN

NN N

NNNNNNNNN

115-230 V AC

N

N

DC input voltage range

90-300 V DC

90-375 V DC

N

120-375 V DC N N N N N N N

NN N

NN N

NNNNNNNNN N

210-375 V DC

N

NN

N

Features Power reserve design

NNNNNNNNN

Adjustable output voltage

N

NNNNN N N N N N N NNN N NNNNNNNNNN

Integrated input fuse N N N N N N N N N N N N N N N N N N N N N N N N N N N N

Short-circuit stable N N N N N N N N N N N N N N N N N N N N N N N N N N N N

Fold-forward behavior (U/I)

N

NNN

NN

N N N N NNN N NNNNNNNNNN

Fold-back behavior (hiccup) N

N

N

N

Power factor correction

pas

pas pas act

pas act act act act act act act act act act

Signalling contact

NNN NN

NNNNNNNNN

Extended temp. range N N N N N N

NN

N N N N NNN N N

NNN

Parallel connection

NN 3 N N N 3 3 3NN 3 3 5 5 5 5 5 5 5 5 5

Serial connection N N N N N N N N 2 N N N 2 2 2 N N 2 2 2 2 2 2 2 2 2 2 2

Coated PCBA

NNN

pas = passive, act = active

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

251

-- Primary switch mode power supplies Selection table - Three-phase

Order number 1SVR427054R0000 1SVR427055R0000 1SVR427056R0000 1SVR427057R0000 1SVR427054R2000 1SVR427055R2000 1SVR427056R2000

Rated output voltage Rated output current
Rated output power
Rated input voltage

Three-phase

CP-T

24 V DC N N N N

48 V DC

NNN

5A N

N

10 A

N

N

20 A

N

N

40 A

N

120 W N

240 W

N

N

480 W

N

N

960 W

N

N

3 x 400-500 V AC
NNNNNNN

DC input voltage range

480-820 V DC
NNNNNNN

Features

Adjustable output voltage N N N N N N N

Integrated input fuse N N N N N N N

Short-circuit stable N N N N N N N

Fold forward behavior (U/I) N N N

NN

Fold back behavior (hiccup) N N N N N N N

Extended temp. range N N N N N N N

Signalling contact N N N N

Parallel connection

222222

Serial connection

222222

252

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

253

-- Power supplies for industrial applications Table of contents

255

CP-E range

275

CP-T range

289

CP-C.1 range

254

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

255

-- CP-E range Table of contents

256

Benefits and advantages

258

Operating controls

259

Applications

260

Ordering details

261

Technical data

271

Technical diagrams

256

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Benefits and advantages

ABB's CP-E range offers enhanced functionality and a simpler, more rational selection process. All power supply units can be operated at an ambient temperature of up to +70 °C (158 °F).

Affordable range

Products with exactly the functions you require. Designed for best possible price-performance ratio.

Global availability

The product can be used in any installations in the world. Giving you the confidence of worldwide sourcing ­ no matter where you build, install or operate your equipment.

Speed up your projects

Data available for common planning software: Less engineering time required.

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

257

-- CP-E range Benefits and advantages

Characteristics · Output voltages 5 V, 12 V, 24 V, 48 V DC · Adjustable output voltages · Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / 3 A / 5 A / 10 A / 20 A · Power range 15 W, 18 W, 30 W, 60 W, 120 W, 240 W, 480 W · High efficiency, up to 90 % · Low power dissipation and low heating · Free convection cooling (no forced cooling with ventilators) · Open-circuit, overload and short-circuit stable · Integrated input fuse · U/I characteristic curve on devices > 18 W (fold-forward behavior at overload ­ no switch-off) · Redundancy units offering true redundancy · LED(s) for status indication · Signalling output/contact for output voltage OK
- Transistor on 24 V devices > 18 W and < 120 W - Solid-state on 24 V devices  120 W · Various approvals and marks

Main benefits
Signalling output / contact The CP-E range 24 V devices > 18 W offer an output/contact for monitoring of the output voltage and remote diagnosis.

Wide range input Optimized for worldwide applications: The CP-E power supplies can be supplied with a wide range of AC or DC voltages.

Adjustable output voltage A continuously adjustable output voltage ensures optimal adaptation to the application, e.g. compensating the voltage drop caused by a long line length.

Redundancy units For decoupling of parallelized power supply units  40 A. Thus, true redundancy can be achieved.

258

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Operating controls

OUTPUT Adjust: Potentiometer  adjustment of output voltage
Indication of operational states: OUTPUT OK: green LED  output voltage OK OUTPUT LOW: red LED  output voltage too low

Single/parallel: Sliding switch adjustment of single or parallel operation
OUTPUT L+, L+, L, L-: Terminals  output 5 V / 12 V / 24 V / 48 V
13-14: Terminals  signalling contact (or solid-state)
Circuit diagram

INPUT L, N, PE: terminals  input 90-132 V AC, 180-265 V AC / 210-375 V DC 90-264 V AC / 120-375 V DC 85-264 V AC / 90-375 V DC

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

259

-- CP-E range Applications

Tooling machines

Packaging industry

Food industry

Textile industry

Printing industry

Electromobility

260

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Ordering details

CP-E 5/0.75 CP-E 12/2.5 CP-E 48/5.0 CP-E 24/20.0

2CDC 271 013 F0006

2CDC 271 027 F0008

2CDC 271 028 F0008

2CDC 271 017 F0006

-- Description This range offers types with output voltages from 5 V DC to 48 V DC at output currents of 0.625 A to 20 A. With their high thermal efficiency of up to 90 %, these power supplies have very low power and heat dissipation and can be operated without forced cooling. The functionality has been enhanced while the number of different types has been considerably reduced. Of course, all power supplies of the CP-E range are approved in accordance with all relevant international standards.

-- Ordering details - CP-E < 100 W

Input voltage range

Rated output

Type

voltage / current

90-264 V AC / 120-375 V DC

5 V DC / 3 A

CP-E 5/3.0

85-264 V AC / 90-375 V DC

12 V DC / 2.5 A

CP-E 12/2.5

90-132 V AC, 180-264 V AC / 210-375 V DC
90-264 V AC / 120-375 V DC

12 V DC / 10 A 24 V DC / 0.75 A

CP-E 12/10.0 CP-E 24/0.75

85-264 V AC / 90-375 V DC

24 V DC / 1.25 A CP-E 24/1.25

85-264 V AC / 90-375 V DC

24 V DC / 2.5 A

CP-E 24/2.5

Order code
1SVR427033R3000 1SVR427032R1000 1SVR427035R1000 1SVR427030R0000 1SVR427031R0000 1SVR427032R0000

Weight (1 pc.) kg (lb)
0.15 (0.33)
0.29 (0.64)
1.00 (2.20)
0.15 (0.33)
0.29 (0.64)
0.36 (0.79)

-- Ordering details - CP-E M 120 W

Input voltage range

Rated output voltage / current

Type

90-132 V AC, 180-264 V AC / 210-375 V DC
90-132 V AC, 180-264 V AC / 210-375 V DC
90-264 V AC / 120-375 V DC

24 V DC / 5 A 24 V DC / 10 A 24 V DC / 20 A

CP-E 24/5.0 CP-E 24/10.0 CP-E 24/20.0

85-264 V AC / 90-375 V DC

48 V DC / 0.625 A CP-E 48/0.62

85-264 V AC / 90-375 V DC

48 V DC / 1.25 A CP-E 48/1.25

90-132 V AC, 180-264 V AC / 210-375 V DC
90-264 V AC / 120-375 V DC

48 V DC / 5 A 48 V DC / 10 A

CP-E 48/5.0 CP-E 48/10.0

Order code
1SVR427034R0000 1SVR427035R0000 1SVR427036R0000 1SVR427030R2000 1SVR427031R2000 1SVR427034R2000 1SVR427035R2000

Weight (1 pc.) kg (lb)
1.00 (2.20)
1.36 (3.01)
1.90 (4.18)
0.29 (0.64)
0.36 (0.79)
1.36 (3.01)
1.90 (4.19)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

261

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type Input circuit Rated input voltage Uin

CP-E 5/3.0 L, N 100-240 V AC

CP-E 12/2.5

CP-E 12/10.0
115 / 230 V AC auto select

Input voltage range

90-264 V AC / 120-375 V DC

85-264 V AC / 90-375 V DC

90-132 V AC, 180-264 V AC / 210-375 V DC

Frequency range AC Typical input current
Typical power consumption Inrush current
Discharge current
Power failure buffering time
Internal input fuse

47-63 Hz

at 115 V AC 335 mA

560 mA

at 230 V AC 210 mA

330 mA

19.8 W

35.9 W

at 115 V AC 15 A

20 A

at 230 V AC 30 A

40 A

input / output 0.25 mA

input / PE 3.5 mA

at 115 V AC min. 20 ms

min. 20 ms

at 230 V AC min. 75 ms

min. 30 ms

2 A slow-acting / 250 V AC

2.2 A 0.83 A 143 W 24 A 48 A
min. 25 ms min. 30 ms 3.15 A slow-acting / 250 V AC

Power factor correction (PFC) Indication of operational states Output voltage

no
green LED OK: V: output voltage OK

yes, passive, 0.7

OUTPUT OK: V: output voltage OK

OUTPUT OK: V: output voltage OK

red LED LOW: V:

-

output voltage too low

OUTPUT LOW: V: output voltage too low

Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current Maximum deviation with

L+,L5 V DC 0...+1 % 4.5-5.75 V DC 15 W Ta m 60 °C 3.0 A 60 °C < Ta m 70 °C 2.5 %/°C load change statical ±2 %

L+, L+, L-, L12 V DC
12-14 V DC 30 W 2.5 A 2.5 %/°C ±0.5 %

11.4-14.5 V DC 120 W 10 A
±1 % (single mode) ±5 % (parallel mode)

change of output voltage ±1 % within the input voltage range

±0.5 %

±0.5 %

Recovery time TR Starting time after applying the supply voltage
Rise time
Fall time Residual ripple and switching peaks Parallel connection
Series connection

< 2 ms

at Ir max. 1 s with 3500 µF -

max. 2 s

with 7000 µF max. 1.5 s

-

at rated load max. 150 ms

with 3500 µF -

max. 500 ms

with 7000 µF max. 500 ms

-

max. 150 ms

BW = 20 MHz 50 mV

yes, to enable redundancy

yes, to increase voltage

max. 1.5 s
max. 500 ms
configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir yes, to increase voltage, max. 2 devices

Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Overload protection No-load protection Starting of capacitive loads

1 s - max. 7.5 V DC

1 s - max.18 V DC

max. 18 V DC

hiccup-mode

U/I characteristic curve

continuous short-circuit proof

Hiccup-mode

continuation with output power limiting

output power limiting

continuous no-load stability

7000 µF

3500 µF

7000 µF

262

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-E 5/3.0

CP-E 12/2.5

CP-E 12/10.0

General data

Power loss

typ. 5 W

typ. 5.6 W

typ. 24 W

Efficiency

typ. 75 %

typ. 84 %

typ. 84 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

plastic

metal

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit

Connecting capacity

fine-strand with wire end ferrule

0.2-4 mm² (24-11 AWG)

fine-strand without wire end 0.2-2.5 mm2 (24-14 AWG) ferrule

0.2-6 mm² (24-10 AWG)

Stripping length Tightening torque

rigid 6 mm (0.24 in)
input / output 0.6 Nm (5 lb.in)

8 mm (0.31 in)
1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)

Environmental data

Ambient temperature range

operation -20...+70 °C

-40...+70 °C

-35...+70 °C

rated load -20...+60 °C

-40...+60 °C

-35...+60 °C

storage -20...+85 °C

-40...+85 °C

-40...+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 RH, % without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 3 kV AC input / PE 1.5 kV AC

output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Overvoltage category

II

Standards / Directives

Standards

IEC/EN 60950-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields

IEC/EN 61000-4-4 level 4 (4 kV / 2,5 kHz) level 4 (4 kV / 5 kHz) IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) IEC/EN 61000-4-6 level 3 (10 V)

power frequency magnetic fields
voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-8 level 4 (30 A/m)
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms

Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions

IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class D

class A

class D

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

263

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type Input circuit Rated input voltage Uin Input voltage range

CP-E 24/0.75 L, N 100-240 V AC 90-264 V AC / 120-375 V DC

CP-E 24/1.25
85-264 V AC / 90-375 V DC

CP-E 24/2.5

Frequency range AC Typical input current
Typical power consumption Inrush current
Discharge current
Power failure buffering time
Internal input fuse Power factor correction (PFC) Indication of operational states Output voltage

47-63 Hz

at 115 V AC 335 mA

560 mA

at 230 V AC 210 mA

330 mA

22.8 W

36.7 W

at 115 V AC 15 A

20 A (max. 3 ms)

at 230 V AC 30 A

40 A (max. 3 ms)

input / output 0.25 mA

input / PE 3.5 mA

at 115 V AC min. 20 ms

min. 20 ms

at 230 V AC min. 75 ms

min. 30 ms

2 A slow-acting / 250 V AC

no

1060 mA 590 mA 69.2 W 30 A 60 A

green LED OK: V: output voltage OK

OUTPUT OK: V: output voltage OK

red LED LOW: V:

-

-

output voltage too low

Output circuit

L+,L-

L+, L+, L-, L-

Rated output voltage

24 V DC

Tolerance of the output voltage

0 ... +1 %

Adjustment range of the output voltage

21.6-28.8 V DC

24-28 V DC

Rated output power

18 W

30 W

Rated output current Ir Derating of the output current Signalling output for output voltage OK

Ta m 60 °C 0.75 A 60 °C < Ta m 70 °C 2.5 %/°C
DC OK -

1.25 A transistor

Maximum deviation with

load change statical ±2 %

±0.5 %

change of output voltage ±1 % within the input voltage range

±0.5 %

Recovery time TA Starting time after applying the supply voltage

< 2 ms at Ir max. 1 s with 3500 µF -

max. 2 s

with 7000 µF max. 1.5 s

-

Rise time

at rated load max. 150 ms

with 3500 µF -

max. 500 ms

with 7000 µF max. 500 ms

-

Fall time

max. 150 ms

Residual ripple and switching peaks

BW = 20 MHz 50 mV

Parallel connection

yes, to enable redundancy

60 W 2.5 A
max. 1.5 s max. 500 ms

Series connection

yes, to increase voltage

Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Overload protection No-load protection Starting of capacitive loads

1 s - max. 35 V DC

hiccup-mode

U/I characteristic curve

continuous short-circuit proof

hiccup-mode

continuation with output power limiting

output power limiting

continuous no-load stability

7000 µF

3500 µF

7000 µF

264

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-E 24/0.75

CP-E 24/1.25

CP-E 24/2.5

General data

Power loss

typ. 4.45 W

typ. 5.5 W

typ. 8.8 W

Efficiency

typ. 77 %

typ. 86 %

typ. 89 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit

Connecting capacity

fine-strand with wire end ferrule

fine-strand without 0.2-2.5 mm2 (24-14 AWG) wire end ferrule

rigid

Stripping length

6 mm (0.24 in)

Tightening torque

input / output 0.6 Nm (5 lb.in)

Environmental data

Ambient temperature range

operation -20...+70 °C

-40...+70 °C

rated load -20...+60 °C

-40...+60 °C

storage -20...+85 °C

-40...+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % RH, without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 3 kV AC input / PE 1.5 kV AC

output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Overvoltage category

II

Standards / Directives

Standards

IEC/EN 60950-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 level 4 (4 kV / 2.5 kHz) level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields

IEC/EN 61000-4-6 level 3 (10 V)

power frequency magnetic fields
voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms

Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions

IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class D

class A

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

265

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type Input circuit Rated input voltage Uin Input voltage range
Frequency range AC Typical input current
Typical power consumption Inrush current
Discharge current
Power failure buffering time
Internal input fuse

CP-E 24/5.0

CP-E 24/10.0

L, N

115 / 230 V AC auto select

90-132 V AC, 180-264 V AC / 210-375 V DC

90-132 V AC, 180-264 V AC / 210-375 V DC

47-63 Hz

at 115 V AC 2.2 A

4.0 A

at 230 V AC 0.83 A

1.55 A

140 W

270 W

at 115 V AC 24 A (max. 5 ms)

30 A (max. 5 ms)

at 230 V AC 48 A (max. 5 ms)

60 A (max. 5 ms)

input / output 0.25 mA

input / PE 3.5 mA

at 115 V AC min. 25 ms

at 230 V AC min. 30 ms

3.15 A slow-acting / 250 V AC

6.3 A slow-acting / 250 V AC

CP-E 24/20.0
115-230 V AC 90-264 V AC, 120-375 V DC
4.9 A 2.5 A 539 W 25 A (max. 5 ms) 50 A (max. 5 ms)
10 A slow-acting / 250 V AC

Power factor correction (PFC)

yes, passive, 0.7

yes, passive, 0.75

yes, active 115 V AC: 0.99 230 V AC: 0.97

Indication of operational states Output voltage
Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir
Derating of the output current
Signalling contact for output voltage OK Minimum fuse rating to achieve short-circuit protection

green LED OUTPUT OK: V: output voltage OK

red LED OUTPUT LOW: V: output voltage too low

L+, L+, L-, L-

24 V DC

0...+1 %

22.5-28.5 V DC

120 W

240 W

Ta m 60 °C 5 A

10 A

Ta m 55 °C -

-

60 °C < Ta m 70 °C 2.5 %/°C

55 °C < Ta m 70 °C -

-

13-14 solid-state (max. 60 V DC, 0.3 A)

13-14 M 60 V DC, m 0.3 A fast-acting

480 W 20 A 2.5 %/°C

Maximum deviation with

load change statical ±1 % (single mode), ±5 % (parallel mode)
change of output voltage ±0.5 % within the input voltage range

Recovery time TR Starting time after applying the supply voltage
Rise time
Fall time Residual ripple and switching peaks Parallel connection Series connection Resistance to reverse feed

< 2 ms

at Ir max. 1 s

2.5 s (at -40 °C / 90 V AC starting time >2.5 s has to be expected)

max. 1 s

with 3500 µF max. 1.5 s

-

-

with 7000 µF -

2.5 s

max. 1.5 s

at rated load max. 150 ms

with 3500 µF max. 500 ms

-

-

with 7000 µF -

max. 500 ms

max. 150 ms

BW = 20 MHz 50 mV

100 mV

configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir yes, to increase voltage, max. 2 devices

max. 35 V DC

266

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-E 24/5.0

CP-E 24/10.0

CP-E 24/20.0

Output circuit - No-load, overload and short-circuit behavior

Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit proof

Short-circuit behavior

continuation with output power limiting

Overload protection

output power limiting

No-load protection

continuous no-load stability

Starting of capacitive loads

3500 µF

7000 µF

General data

Power loss

typ. 20 W

typ. 35 W

typ. 63 W

Efficiency

typ. 86 %

typ. 89 %

typ. 89 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

metal

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit

Connecting capacity

fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)

fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)

rigid

Stripping length

8 mm (0.31 in)

Tightening torque

input / output 1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)

Environmental data

Ambient temperature range

operation -35...+70 °C

-40...+70 °C

rated load -35...+60 °C

-40...+60 °C

-40...+55 °C

storage -40...+85 °C

-40...+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % RH, without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 3 kV AC input / PE 1.5 kV AC

output / PE 0.5 kV AC; 0.71 kV DC

signalling contact / PE 0.5 kV DC

Pollution degree

2

Overvoltage category

II

Standards / Directives

Standards

IEC/EN 60950-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

267

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field

CP-E 24/5.0

CP-E 24/10.0

CP-E 24/20.0

IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV) IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields power frequency magnetic fields voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-4 level 4 (4 kV / 5 kHz)

level 4 (4 kV / 2.5 kHz)

IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV)

IEC/EN 61000-4-6 level 3 (10 V)

IEC/EN 61000-4-8 level 4 (30 A/m)
IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms interruptions: >95 % 5000 ms

Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions

IEC/EN 61000-6-3 class B class B class D

268

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-E 48/0.62

CP-E 48/1.25

Input circuit

L, N

Rated input voltage Uin

100-240 V AC

CP-E 48/5.0
115 / 230 V AC auto select

CP-E 48/10.0 115-230 V AC

Input voltage range

85-264 V AC / 90-375 V DC

90-132 V AC, 180-264 V AC / 210-375 V DC

90-264 V AC, 120-375 V DC

Frequency range AC Typical input current
Typical power consumption Inrush current
Discharge current
Power failure buffering time
Internal input fuse

47-63 Hz

at 115 V AC 560 mA

1060 mA

at 230 V AC 330 mA

590 mA

35.7 W

69.0 W

at 115 V AC 20 A

30 A

at 230 V AC 40 A

60 A

input / output 0.25 mA

input / PE 3.5 mA

at 115 V AC min. 20 ms

at 230 V AC min. 30 ms

2 A slow-acting / 250 V AC

4.0 A 1.55 A 267 W 30 A (max. 5 ms) 60 A (max. 5 ms)

4.9 A 2.5 A 528 W 25 A (max. 5 ms) 50 A (max. 5 ms)

min. 25 ms

min. 25 ms

6.3 A slow-acting / 10 A slow-acting /

250 V AC

250 V AC

Power factor correction (PFC)

no

yes, passive, 0.7 yes, active

115 V AC: 0.99

230 V AC: 0.97

Indication of operational states Output voltage

green LED OUTPUT OK: V: output voltage OK

red LED -

-

OUTPUT LOW: V:

output voltage too low

Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir
Derating of the output current
Signalling output for output voltage OK Maximum deviation with

L+, L+, L-, L48 V DC 0...+1 % 48-55 V DC 30 W Ta m 60 °C 0.625 A Ta m 55 °C 60 °C < Ta m 70 °C 2.5 %/°C 55 °C < Ta m 70 °C DC OK load change statical ±0.5 %

60 W 1.25 A -
-

47-56 V DC

240 W

480 W

5 A

-

-

10 A

-

-

2.5 %/°C

-

-

±1 % (single mode) ±5 % (parallel mode)

change of output voltage ±0.5 % within the input voltage range

±0.5 %

Recovery time TR Starting time after applying the supply voltage
Rise time
Fall time Residual ripple and switching peaks Parallel connection
Series connection

< 2 ms

at Ir max. 1 s

with 3500 µF max. 2 s

-

with 7000 µF -

max. 1.5 s

at rated load max. 150 ms

with 3500 µF max. 500 ms

-

with 7000 µF -

max. 500 ms

max. 150 ms

BW = 20 MHz 50 mV

yes, to enable redundancy

yes, to increase voltage

-

-

max. 1.5 s

-

-

max. 500 ms

100 mV
configurable, to increase power, up to 3 devices, min. 0.1 Ir - max. 0.9 Ir
yes, to increase voltage, max. 2 devices

Resistance to reverse feed

1 s - max. 63 V DC

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

269

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-E 48/0.62

CP-E 48/1.25

CP-E 48/5.0

CP-E 48/10.0

Output circuit - No-load, overload and short-circuit behavior

Characteristic curve of output

U/I characteristic curve

Short-circuit protection

continuous short-circuit proof

Short-circuit behavior

continuation with output power limiting

Overload protection

output power limiting

No-load protection

continuous no-load stability

Starting of capacitive loads

3500 µF

7000 µF

unlimited

7000 µF

General data

Power loss

typ. 4.9 W

typ. 7.8 W

typ. 32 W

typ. 60 W

Efficiency

typ. 86 %

typ. 89 %

typ. 90 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

plastic

metal

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP/20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit

Connecting capacity

fine-strand with 0.2-2.5 mm² (24-14 AWG) wire end ferrule

0.2-4 mm² (24-11 AWG)

fine-strand without wire end ferrule

0.2-6 mm² (24-10 AWG)

rigid

Stripping length

6 mm (0.24 in)

8 mm (0.31 in)

Tightening torque

input / output 0.6 Nm (5 lb.in)

1.0 Nm (9 lb.in) / 0.62 Nm (5.5 lb.in)

Environmental data

Ambient temperature range

operation -40...+70 °C

rated load -40...+60 °C

-40...+55 °C

storage -40...+85 °C

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % RH, without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2 G, along X, Y, Z each axis, 60 min. for each axis

Shock (half-sine) (IEC/EN 60068-2-27)

15 G, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 3 kV AC input / PE 1.5 kV AC

output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Overvoltage category

II

Standards / Directives

Standards

EN 61204-3

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

270

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-E 48/0.62

CP-E 48/1.25

CP-E 48/5.0

CP-E 48/10.0

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 level 4 (4 kV / 5 kHz)

level 4 (4 kV / 2.5 kHz)

surge

IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV)

conducted disturbances, induced by radiofrequency fields

IEC/EN 61000-4-6 level 3 (10 V/m)

power frequency magnetic fields
voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dip: >95 % 10 ms / >30 % 500 ms, interruptions: >95 % 5000 ms

Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions

IEC/EN 61000-6-3 class B class B class A

class D

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

271

-- CP-E range Technical diagrams

2C2DCC 2D72C020762F00b0076 F0b07

22CDCCD2C72207027 F000b708F0b08

-- Output curve at Ta = 25 °C
Uout [V] 15 13 11
9 7 5 3 1
2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Iout [A]
CP-E 12/2.5
Uout [V]
2.75 2.85 2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Iout [A]
CP-E 24/2.5
Uout [V] 28 24 20 16 12 8 4
4 8 12 16 20 24 28 32 Iout [A]
CP-E 24/20.0
Uout [V] 56 48 40 32 24 16 8
1 2345678 Iout [A]
CP-E 48/5.0

22CDCCD2C72207029 F000b908F0b08

22CDCCD2C72207028 F000b808F0b08

22CDCCD27C2200772F00b0077 F0b07

2CDC 272 008 F0b07
2CDC 272 008 F0b07

Uout [V]
14 12 10 8 6 4 2
2 4 6 8 10 12 14 16 Iout [A]
CP-E 12/10.0
Uout [V]
28 24 20 16 12 8 4
1 2345678 Iout [A]
CP-E 24/5.0
Uout [V]
70 60 50 40 30 20 10
0.6650.705 0.745 0.7850.8250.8650.9050.9450.9851.025 Iout [A]
CP-E 48/0.62
Uout [V]
56 48 40 32 24 16 8
2 4 6 8 10 12 14 16 Iout [A]
CP-E 48/10.0

22CCDCD2C72207120 F001b008F0b08

22CDCCD27C2 020792F00b0079 F0b07

22CDCCD27C2207062 F000b068F0b08

22CDCCD27C2207052 F000b058F0b07

Uout [V]
1.25 1.35 1.45 1.55 1.65 1.75 1.85 1.95 2.05 2.15 Iout [A]
CP-E 24/1.25
Uout [V] 28 24 20 16 12 8 4
2 4 6 8 10 12 14 16 Iout [A]
CP-E 24/10.0
Uout [V] 70 60 50 40 30 20 10
1.33 1.41 1.49 1.57 1.65 1.73 1.81 1.89 1.97 2.05 Iout [A]
CP-E 48/1.25

22CDCCD27C2201702F00b1070 F0b07

272

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-E range Technical diagrams

2CDC 272 018 F0211

-- Temperature behavior at Ta = 25 °C
Pout [%]

100 90 80 70 60 50 40 30 20 10
-35
CP-E 12/10.0, CP-E 24/5.0

60 70 Ta [°C]

Pout [%]
100 90 80 70 60 50 40 30 20 10
-20
CP-E 5/3.0, CP-E 24/0.75

60 70 Ta [°C]

2CDC 272 016 F0211

2CDC 272 015 F0211

Pout [%]
100 90 80 70 60 50 40 30 20 10
-40
CP-E 24/20.0, CP-E 48/10.0

55

70

Ta [°C]

Pout [%]

100 90 80 70 60 50 40 30 20 10

-40

60 70

Ta [°C]

CP-E 12/2.5, CP-E 24/1.25, CP-E 48/0.62, CP-E 24/2.5, CP-E 48/1.25, CP-E 24/10.0, CP-E 48/5.0

2CDC 272 017 F0211

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

273

-- CP-E range Technical diagrams

22CCDDCC27227201071F70F2007207

-- Wiring instructions

Relay
RL > 700  DC OK
LCP-E 24/1.25, CP-E 24/2.5

5 V Signal

DC OK L-

2.2 k 0.5 W 5.1 V 0.3 W

-- Dimensional drawings Dimensions in mm, inches

114 4.49"

22.5 0.89"

40.5 1.59"

90 3.54" 90 3.54"
2CDC 272 021 F0011

123.6 [4.87"] 116.6 [4.59"]

CP-E 5/3.0, CP-E 24/0.75

CP-E 12/2.5, CP-E 24/1.25, CP-E 24/2.5, CP-E 48/0.62, CP-E 48/1.25

63.2 [2.49"]

83.0 [3.27"]

175.0 [6.89"]

123.6 [4.87"] 123.6 [4.87"] 123.6 [4.87"]

2CD2CCD2C72272010133FF00b0808

CP-E 12/10.0, CP-E 24/5.0

CP-E 24/10.0, CP-E 48/5.0

CP-E 24/20.0, CP-E 48/10.0

2 74

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

275

-- CP-T range Table of contents

276

Benefits and advantages

278

Operating controls

279

Applications

280

Ordering details

281

Technical data

285

Technical diagrams

276

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-T range Benefits and advantages

ABB's CP-T range of three-phase power supply units perfectly complements our existing power supply offering in terms of design and functionality, giving you more advanced options for your three-phase applications.

Affordable range

Products with exactly the functions you require. Designed for best price-performance ratio.

Global availability

The product can be used in any installation in the world. Giving you the confidence of world-wide sourcing ­ no matter where you build, install or operate your equipment.

Speed up your projects

Data available for common planning software: Less engineering time required

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

277

-- CP-T range Benefits and advantages

Characteristics · Rated output voltages 24 V, 48 V DC · Output voltage adjustable via front-facing rotary potentiometer "OUTPUT Adjust" · Rated output currents 5 A, 10 A, 20 A, 40 A · Rated output powers 120 W, 240 W, 480 W, 960 W · Three-phase operation (see derating note) · Two-phase operation (25 % derating possible, see derating note) · Supply range 3 x 400­500 V AC (3 x 340-575 V AC, 480-820 V DC) · Typical efficiency of 93 % · Low power dissipation and low heating · Free convection cooling (no forced cooling with ventilators) · Ambient temperature range during operation -40...+70 °C 1) · Open-circuit, overload and short-circuit stable · Integrated input fuse · Redundancy unit CP-C.1-A-RU (-C) offering true redundancy, available as accessory · LEDs for status indication · Signalling contact "13-14" (solid-state) for output voltage OK on 24 V devices · Various approvals and marks
1) 480 W variants: -30...+70°C

Main benefits
Signalling output Some devices of the CP-T series offer a solid-state output for function monitoring and remote diagnostics.

Wide input range Optimized for worldwide applications: The CP-T power supplies can be used in 340 - 575 V AC or 480 - 820 V DC supply systems.

Adjustable output voltage The CP-T range features a continuously adjustable output voltage. Thus, they can be optimally adapted to the applications, e.g. compensating the voltage drop caused by a long line length.

278

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-T range Operating controls

Indication of operational states · OUTPUT OK: green
LED  green LED  output voltage OK · OUTPUT LOW: red LED  output voltage too low

Circuit diagram
INPUT L1, L2, L3, PE: Terminals - input 340-575 V AC / 480-820 V DC
OUTPUT L+, L+, L, L-: Terminals  output 24 V DC, 48 V DC

OUTPUT Adjust: Potentiometer  adjustment of output voltage 22.5...28.5V DC
Single/parallel: Sliding switch adjustment of single or parallel operation
13-14: Terminals - signalling contact A solid-state output indicates the error-free operation of the output voltage

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

279

-- CP-T range Applications

Tunnel drilling machines

Floor conveyors

Quality power management systems

280

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-T range Ordering details

CP-T 24/5.0 CP-T 24/10.0, CP-T 48/5.0 CP-T 24/20.0, CP-T 48/10.0

2CDC 271 043 S0009

2CDC 271 045 S0009

2CDC 271 047 S0009

Description
In terms of design and functionality, the CP-T range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a three-phase voltage as well as with two-phase mains. Here, ABB offers power supply units with 24 V DC and 48 V DC outputs with 5 A, 10 A, 20 A and 40 A and efficiency of up to 93 %.

As in the case of all products, they are designed for an ambient temperature of up to 70 °C. All products can be supplied within an AC supply voltage range between 340 to 575 V AC and a DC supply voltage range between 480 to 820 V DC.

-- Ordering details
Input voltage range
340-575 V AC / 480-820 V DC

Rated output voltage / current

Type

24 V DC / 5 A

CP-T 24/5.0

340-575 V AC / 480-820 V DC

24 V DC / 10 A

CP-T 24/10.0

340-575 V AC / 480-820 V DC

24 V DC / 20 A

CP-T 24/20.0

340-575 V AC / 480-820 V DC

24 V DC / 40 A

CP-T 24/40.0

340-575 V AC / 480-820 V DC

48 V DC / 5 A

CP-T 48/5.0

340-575 V AC / 480-820 V DC

48 V DC / 10 A

CP-T 48/10.0

340-575 V AC / 480-820 V DC

48 V DC / 20 A

CP-T 48/20.0

Order code
1SVR427054R0000 1SVR427055R0000 1SVR427056R0000 1SVR427057R0000 1SVR427054R2000 1SVR427055R2000 1SVR427056R2000

Weight (1 pc.) kg (lb)
0.80 (1.77)
1.05 (2.31)
1.75 (3.86)
3.20 (7.05)
1.05 (2.31)
1.75 (3.86)
3.40 (7.50)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

281

-- CP-T range Technical data

Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated

Type

CP-T 24/5.0

CP-T 24/10.0

CP-T 24/20.0

CP-T 24/40.0

Input circuit

L1, L2, L3

Rated input voltage Uin Input voltage range

3 x 400-500 V AC 340-575 V AC

480-820 V DC

Frequency range AC

47-63 Hz

Typical input current

0.36 A

0.65 A

1.1 A

1.72 A

Typical power consumption

135 W

270 W

538 W

1058 W

Inrush current

typ. 10 A

20 A

30 A

Power failure buffering time

min. 20 ms

min. 15 ms

Internal input fuse

per phase 2 A / 600 V AC

T 3.15 A / 500 V AC T 5 A / 500 V AC

Recommended backup fuse

3 pole miniature circuit breaker ABB Type S203

Power factor correction (PFC)

yes, passive

Discharge current

towards PE < 3.5 mA

input / output < 0.25 mA

Indication of operational states

Output voltage

OUTPUT OK: green LED output voltage OK when the output voltage > 75 % of the rated output voltage

OUTPUT LOW: red LED output voltage too low when the output voltage < 70 % of the rated output voltage

Output circuit

L+, L+, L-, L-

Rated output voltage

24 V DC

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

22.5-28.5 V DC

Rated output power

120 W

240 W

480 W

960 W

Rated output current Ir Derating of the output current
Signalling contact for output voltage OK

Ta  60 °C 5 A

10 A

60 °C < Ta  70 °C 2.5 %/°C

13-14 solid-state (max. 60 V DC, 0.3 A)

Threshold 17.6-19.4 V

20 A

40 A 3.5 %/°C

Insulation voltage 500 V DC

Mininum fuse rating to achieve short-circuit protection

13-14 M 60 V DC, m 0.3 A fast-acting

Maximum deviation with

load change statical ±1 %

±1 % (single mode)

-

±5 % (parallel mode)

change of output voltage ± 0.5 % within the input voltage range

Recovery time TA Starting time after applying the supply voltage
Rise time

Fall time Residual ripple and switching peaks Parallel connection

BW = 20 MHz

at nominal load < 2 ms at Ir max. 1 s
with 3500 µF max. 1.5 s at nominal load max. 150 ms
with 3500 µF max. 500 ms max. 150 ms 100 mV not supported

configurable, to increase power, up to 2 devices, min. 0.1 Ir - max 0.9 Ir

80 mV
to increase power, up to 2 devices, min. 0.1 Ir - max. 0.9 Ir,use active current balancing

Series connection Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output

not supported approx. 35 V

yes, to increase voltage, max. 2 devices

combined U/I characteristic curve U/I- or hiccup- hiccup / fold

and hiccup mode

mode adjustable back behavior

Short-circuit protection Short-circuit behavior Overload protection No-load protection Overtemperature protection Starting of capacitive loads

continuous short-circuit proof

current limiting

hiccup mode

continuous no-load stability

yes, automatic recovery after temperature went down

3500 µF

7000 µF

7000 µF

7000 µF

282

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-T range Technical data

Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated

Type

CP-T 24/5.0

CP-T 24/10.0

CP-T 24/20.0

CP-T 24/40.0

General data

Efficiency

typ. 89 %

typ. 90 %

typ. 92 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

metal

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit / signalling circuit

Connecting capacity

fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)

fine-strand without wire end 0.2-6 mm² (24-10 AWG) ferrule

Stripping length Tightening torque

rigid 0.2-6 mm² (24-10 AWG) 8 mm (0.31 in)
input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in)

1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in)

Environmental data

Ambient temperature range

operation -40...+70 °C

-30...+70 °C

rated load -40...+60 °C

-30...+60 °C

storage -40...+85 °C

Altitude during operation

IEC/EN 60068-2-13 max. 5000 m

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2G, each along X, Y, Z axes 60 min / cycle

Shock (half-sine) (IEC/EN 60068-2-27)

15 g, 11 ms, 3 axes, 6 faces, 3 times for each face

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 3 kV AC input / PE 1.5 kV AC

output / PE 0.5 kV AC; 0.71 kV DC

signalling output / PE 0.5 kV DC

Pollution degree

2

Standards / Directives

Standards

IEC/EN 60950-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

-40...+70 °C -40...+60 °C

electrical fast transient/burst

IEC/EN 61000-4-4 level 4

level 4 (4 kV / 5 kHz)

(4 kV / 2.5 kHz)

surge
conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV) IEC/EN 61000-4-6 level 3 (10 V)

power frequency magnetic fields
voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-8 level 4 (30 A/m) IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms, interruptions: >95 % 250 ms

Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions

IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class A

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

283

-- CP-T range Technical data

Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated

Type

CP-T 48/5.0

CP-T 48/10.0

CP-T 48/20.0

Input circuit

L1, L2, L3

Rated input voltage Uin Input voltage range

3 x 400-500 V AC 340-575 V AC

480-820 V DC

Frequency range AC

47-63 Hz

Typical input current

0.65 A

1.1 A

1.72 A

Typical power consumption

264 W

535 W

1050 W

Inrush current

typ. 20 A

30 A

Power failure buffering time

min. 20 ms

min. 15 ms

Internal input fuse

per phase 2 A / 600 V AC

T 3.15 A / 500 V AC

T 5 A / 500 V AC

Power factor correction (PFC)

yes, passive

Discharge current

towards PE < 3.5 mA

input / output < 0.25 mA

Indication of operational states

Output voltage

OUTPUT OK: green LED output voltage OK when the output voltage > 75 % of the rated output voltage

OUTPUT LOW: red LED output voltage too low when the output voltage < 70 % of the rated output voltage

Output circuit

L+, L+, L-, L-

Rated output voltage

48 V DC

Tolerance of the output voltage

0...+1 %

Adjustment range of the output voltage

47-56 V DC

Rated output power

240 W

480 W

960 W

Rated output current Ir Derating of the output current Maximum deviation with

Ta  60 °C 5 A 60 °C < Ta  70 °C 2.5 %/°C load change statical ±1 % (single mode)

10 A

20 A 3.5 %/°C

± 5 % (parallel mode)

change of output voltage within the ±0.5 % input voltage range

Recovery time TA Starting time after applying the supply voltage
Rise time
Fall time Residual ripple and switching peaks Parallel connection

at rated load < 2 ms at Ir max. 1 s
with 7000 µF max. 1.5 s at rated load max. 150 ms with 7000 µF max. 500 ms
max. 150 ms BW = 20 MHz 100 mV
configurable, to increase power, up to 2 devices, min. 0.1 Ir - max 0.9 Ir

80 mV
to increase power, up to 2 devices, min. 0.1 Ir - max. 0.9 Ir, use active current balancing

Series connection Resistance to reverse feed Output circuit - No-load, overload and short-circuit behavior Characteristic curve of output

yes, to increase voltage, max. 2 devices

approx. 35 V

approx. 63 V

approx. 63 V

combined U/I and hiccup mode

U/I or hiccup mode, configurable

hiccup mode / fold back behavior

Short-circuit protection Short-circuit behavior Overload protection No-load protection Over temperature protection Starting of capacitive loads

continuous short-circuit proof current limiting hiccup mode continuous no-load stability yes, automatic recovery after temperature went down 7000 µF

284

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-T range Technical data

Data at Ta = 25 °C, Uin = 3 x 400 V AC and rated values, unless otherwise indicated

Type

CP-T 48/5.0

CP-T 48/10.0

CP-T 48/20.0

General data

Efficiency

typ. 91 %

typ. 93 %

Duty cycle

100%

Dimensions

see "Dimensional drawings"

Material of housing

Metal

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

I

Electrical connection - input circuit / output circuit

Connecting capacity

fine-strand with wire end ferrule 0.2-4 mm² (24-11 AWG)

0.2-4 mm² (24-11 AWG) / 0.5-10 mm² (20-8 AWG)

fine-strand without wire end ferrule 0.2-6 mm² (24-10 AWG)

rigid

Stripping length

8 mm (0.31 in)

Tightening torque

input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in)

1 Nm (9 lb.in) / 1.8 Nm (15.6 lb.in)

Environmental data

Ambient temperature range

operation -40...+70 °C

-30...+70 °C

-40...+70 °C

rated load -40...+60 °C

-30...+60 °C

-40...+60 °C

storage -40...+85 °C

-40...+85 °C

-40...+85 °C

Altitude during operation

IEC/EN 60068-2-13 max. 5000 m

Damp heat (cyclic) (IEC/EN 60068-2-30)

95 % without condensation

Vibration (sinusoidal) (IEC/EN 60068-2-6)

10-500 Hz, 2G, each along X, Y, Z axes 6 min / cycle

Shock (half-sine) (IEC/EN 60068-2-27)

15G, 11 ms, 3 axes, 6 Faces, 3 times for each face

Isolation data

Rated insulation voltage Ui

input circuit / output circuit 3 kV AC input / PE 1.5 kV AC

output / PE 0.5 kV AC; 0.71 kV DC

Pollution degree

2

Standards / Directives

Standards

IEC/EN 60950-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 4 (air discharge 15 kV / contact discharge 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 level 4 (4 kV / 5 kHz)

surge

IEC/EN 61000-4-5 L-L level 3 (2 kV) / L-PE level 4 (4 kV)

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3 (10 V)

power frequency magnetic fields
voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-8 level 4 (30 A/m)
IEC/EN 61000-4-11 dips: >95 % 0.5 ms / >30 % 0.5 ms interruptions: >95 % 250 ms

Interference emission high-frequency radiated high-frequency conducted limits for harmonic current emissions

IEC/EN 61000-6-3 class B class B IEC/EN 61000-3-2 class A

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

285

-- CP-T range Technical diagrams

2CDC 272 034 F0x09

2CDC 272 037 F0x09

-- Output curves at Ta = 25 °C
Uout [V]

28

@ 3 x 400V supply

24

@ 3 x 500V supply

20

16

12

8

4

Hiccup mode

1 2 3 4 5 6 7 8 Iout[A]

CP-T 24/5.0

Uout [V]

28

@ 3 x 400V supply

24

@ 3 x 500V supply

20

16

12

8

4

Hiccup mode

4 8 12 16 20 24 28 32 Iout[A]

CP-T 24/20.0 Hiccup mode

Uout [V]

56

@ 3 x 400V supply

48

@ 3 x 500V supply

40

32

24

16

8

2 4 6 8 10 12 14 16 Iout[A]
CP-T 48/10.0 U/I curve

2CDC 272 038 F0x09

2CDC 272 035 F0x09

2CDC 272 032 F0x09

Uout [V]

28

@ 3 x 400V supply

24

@ 3 x 500V supply

20

16

12

8

4

Hiccup mode

2 4 6 8 10 12 14 16 Iout[A]

CP-T 24/10.0

Uout in V
28 24 20 16 12 8 4

@ 3 x 400 V supply
U/I
Hiccup mode after 2-5 s overload

8 16 24 32 40 48 56 64 72 80 Ioutin A

CP-T 24/40.0

Uout [V]

56

@ 3 x 400V supply

48

@ 3 x 500V supply

40

32

24

16

8

Hiccup mode

2 4 6 8 10 12 14 16 Iout[A]

CP-T 48/10.0 Hiccup mode

2CDC 272 039 F0x09

2CDC 272 027 F0211

2CDC 272 033 F0x09

Uout [V]

28

@ 3 x 400V supply

24

@ 3 x 500V supply

20

16

12

8

4

4 8 12 16 20 24 28 32 Iout[A]
CP-T 24/20.0 U/I curve

Uout [V]

56

@ 3 x 400V supply

48

@ 3 x 500V supply

40

32

24

16

8

Hiccup mode

1 2 3 4 5 6 7 8 Iout[A]

CP-T 48/5.0

Uout in V
56 48 40 32 24 16
8

@ 3 x 400 V supply
U/I
Hiccup mode after 2-5 s overload

4

8

12

16

20

24

28

32

36

40 Iout in A

CP-T 48/20.0

-- Temperature curves at rated load

Pout [%]
100 90 80 70 60 50 40 30 20 10
-40
CP-T 24/40.0, CP-T 48/20.0

60 70 Ta [°C]

2CDC 272 026 F0211

Pout [%]
100 90 80 70 60 50 40 30 20 10
-30
CP-T 24/20.0, CP-T 48/10.0

60 70 Ta [°C]

2CDC 272 030 F0211

Pout [%]

100 90 80 70 60 50 40 30 20 10

-40

60 70

Ta [°C]

CP-T 24/5.0, CP-T 24/10.0, CP-T 48/5.0

2CDC 272 028 F0211

2CDC 272 025 F0211

286

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-T range Technical diagrams

-- Dimensional drawings Dimensions in mm, inches

118.8 4.68`` 111.9 4.41``

118.8 4.68`` 111.89943.4.51``

150 5.91``

2CDC 272 021 F0009 131 5.16`` 124 4.88``
2CDC 272 022 F0009 131 5.16`` 124 4.88``
2CDC 272 023 F0009

CP-T 24/5.0
120.9 4.76`` 112.5 4.43``
CP-T 24/40.0, CP-T 48/20.0

131 5.16`` 124 4.88`` 2CDC 272 011 F0016

CP-T 24/10.0, CP-T 48/5.0

CP-T 24/20.0, CP-T 48/10.0

275.8 10.86``

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

287

288

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

289

-- CP-C.1 range Table of contents

290

Benefits and advantages

292

Operating controls

293

Applications

294

Ordering details

295

Technical data

307

Technical diagrams

290

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Benefits and advantages

The high-performance CP-C.1 power supplies are ABB's most advanced range. With excellent efficiency, high reliability and innovative functionality, it is ready to take on the most demanding of industrial applications These power supplies have a 150 % integrated power reserve, operate at an efficiency of up to 94 % and are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals, CP-C.1 power supplies are the preferred choice for professional DC applications. ATEX and IECEx approvals are available for the use in hazardous areas.

24 7
Continuous operation

· Power reserve design to allow performance with up to 150 % more current · Redundancy setup of the application possible to allow parallel operation · Long lifetime · High peak currents for switching on capacitive loads are supported

$
Project cost reduction

· Up to 94 % efficiency saves money for energy during operation · Less need for external cooling in the cabinet · Small size to reduce space needed in panel

Reliabel in harsh conditions

· Extended ambient temperature range during operation -40...+70 °C with coated PCBA version · IECEx/ATEX approvals for hazardous locations available · High MTBF values

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

291

-- CP-C.1 range Benefits and advantages

Characteristics · Rated output voltage 24 V DC · Power reserve design delivers up to 150 % at Ta  40 °C · Output voltage adjustable via front-facing rotary potentiometer "OUTPUT Adjust", 22.5-28.5 V · High efficiency of up to 94 % · Low power dissipation and low heating · Free convection cooling (no forced cooling) · Devices with coated PCBAs for harsh environments and with extended
temperature range · Open-circuit, overload and short-circuit stable · Integrated input fuse · OUTPUT OK - signaling output "13-14" (relay), Power reserve signaling output "I > IR (transistor) · Redundancy unit offers true redundancy, available as accessory · Various approvals and marks

Main benefits
The primary switch mode power supply CP-C.1 has a wide range of AC and DC input voltages. Furthermore, the CP-C.1 is equipped with capacitors that ensure a hold-up time of at least 50 ms. This enables worldwide usage and permits safe operation in fluctuating networks and battery-powered applications.
With their robust metallic housing and the reliable construction, CP-C.1 power supplies are suitable for applications in industrial environments. The CP-C.1-C units have coated PCBAs, which enables their use in harsh industrial environments. The power reserve of up to 150 % enables trouble-free starting of heavy loads eliminating the need for an oversized power supply.
Signaling output To communicate the status of the power supply, the CP-C.1 is equipped with a relay output to signal OUTPUT OK as well as a transistor output I > IR to indicate when the power reserve is active. These signals can be used for communication with a higher level control system, e.g. a PLC. Depending on the logic of the higher level control system, an appropriate action is initiated by forwarding the signal. The receptor of this signal could be a contactor, a signal tower, or an interface relay.

292

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Operating controls

13-14: Relay output to signal `Output OK'

I > IR: Power reserve transistor output to signal `Power reserve is active'

Side mounting screw holes for DIN rail adapter / lateral mounting
OUTPUT Adjust: Rotary potentiometer Adjustment of output voltage 22.5-28.5 V DC

OUTPUT L+, L: Output terminals 24 V DC
Indication of operational states OUTPUT OK: Green LED POWER RESERVE I > IR: Yellow LED
Circuit diagram
INPUT L(+), N(-), PE: Input terminals 85-264 V AC / 90 - 300 V DC

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

293

-- CP-C.1 range Applications

Application The primary switch mode power supply CP-C.1 has a wide range of AC and DC input voltages. Furthermore, the CP-C.1 is equipped with capacitors that ensure a hold-up time of at least 50 ms. This enables worldwide usage and permits safe operation in fluctuating networks and battery-powered applications. With their robust metallic housing and reliable construction, CP-C.1 power supplies are suitable for applications in industrial environments. The CP-C.1-C units have coated PCBAs, which enables their use in the harshest of industrial environments. usage in even harsh industrial environments. The power reserve of up to 150 % enables trouble-free starting of heavy loads eliminating the need for an oversized power supply.
Adjustable output voltage The CP-C.1 range power supplies feature a continuously adjustable output voltage of 22.5 to 28.5 V DC. Thus, they can be optimally adapted to the applications, e.g. compensating the voltage drop caused by a long line length.
Signaling output To communicate the status of the power supply, the CP-C.1 is equipped with a relay output to signal OUTPUT OK as well as a transistor output I > IR to indicate when the power reserve is active. These signals can be used for communication with a higher level control system, e.g. a PLC.
Power reserve The primary switch mode power supply CP-C.1 is equipped with a power reserve functionality to handle the start-up of particularly heavy loads (e.g. of a capacitive load or a motor). To ensure that heavy loads are started up, the CP-C.1 delivers additionally up to 150 % of the rated output current to secure the operation of the application. This status is displayed by the yellow LED labelled POWER RESERVE I > IR.

294

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Ordering details

CP-C.1 24/5.0 CP-C.1 24/5.0-C
CP-C.1 24/10.0 CP-C.1 24/10.0-C
CP-C.1 24/20.0 CP-C.1 24/20.0-C

2CDC 271 009 F0017

2CDC 271 010 V0017

2CDC 271 011 V0017

Description
High-performance CP-C.1 power supplies are ABB's most advanced range. With excellent efficiency, high reliability, and innovative functionality, it is ready to take on the most demanding industrial applications. These power supplies have up to 50 % integrated power reserve and operate at an efficiency of up to 94 %. They are equipped with overheat protection and active power factor correction. Combined with a broad AC and DC input range and extensive worldwide approvals, the CP-C.1 power supplies are the preferred choice for professional DC applications.

-- Ordering details - CP-C.1

Input voltage range
85-264 V AC, 90-300 V DC

Rated output voltage / current
24 V DC / 5 A

PCBA

Color

Type

uncoated dark grey CP-C.1 24/5.0

Order code 1SVR360563R1001

24 V DC / 10 A

CP-C.1 24/10.0 1SVR360663R1001

24 V DC / 20 A

CP-C.1 24/20.0 1SVR360763R1001

24 V DC / 5 A coated

CP-C.1 24/5.0-C 1SVR360563R2001

24 V DC / 10 A

CP-C.1 24/10.0-C 1SVR360663R2001

24 V DC / 20 A

CP-C.1 24/20.0-C 1SVR360763R2001

24 V DC / 5 A uncoated light grey CP-C.1 24/5.0-L 1SVR361563R1001

24 V DC / 10 A

CP-C.1 24/10.0-L 1SVR361663R1001

24 V DC / 20 A

CP-C.1 24/20.0-L 1SVR361763R1001

Weight (1 pc.) kg (lb)
0.87 (1.92)
1.21 (2.67)
1.70 (3.75)
0.87 (1.92)
1.24 (2.73)
1.72 (3.79)
0.87 (1.92)
1.21 (2.67)
1.70 (3.75)

CP-C.1 24/5.0 light grey
CP-C.1 24/10.0 light grey

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

295

-- CP-C.1 range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C

Input circuit - Supply circuit

L (+), N (-)

Rated input voltage Uin Input voltage range

100-240 V AC, 90-300 V DC AC 85-264 V AC

DC 90-300 V DC

Typical input current

at 115 V AC 1.1 A

at 230 V AC 0.6 A

Typical power consumption

at 230 V AC 132 W

Rated frequency

DC, 50/60 Hz

Frequency range

AC 45-65 Hz

Inrush current, cold state

< 8 A

Let-through energy I2t , cold state

at 230 V AC < 1 A2s

Discharge current towards PE

< 3.5 mA

Hold-up time

at 115 V AC min. 50 ms

at 230 V AC min. 50 ms

Internal input fuse

T4.0 A, not exchangeable

Recommended backup fuse for wire protection at 1.5 mm2

1 pole miniature circuit breaker ABB type S 200 characteristic B or C

max. rating 16 A

Power factor correction (PFC)

yes, active

Transient overvoltage protection

yes, varistor

User interface

Indication of operational states

Output voltage Power reserve Output circuit - Power output

LED `OUTPUT OK ` (green) LED `I > IR' (yellow)

ON flashing
OFF ON

92 % adjusted Uout 90 % adjusted Uout I  IR I > IR

L+, L-

Rated output voltage

24V DC

Tolerance of the output voltage

± 1%

Adjustment range of the output voltage

22.5-28.5 V DC

Rated output power

120 W

Rated output current IR Reserve output current Short-circuit current limiting

- 25 °C m Ta m 60°C 5.0 A - 40 °C m Ta m 60°C - 25 °C m Ta m 40 °C 7.5 A continuously - 40 °C m Ta m 40 °C -
7.6 A

5.0 A 7.5 A continuously

Derating of the output current Deviation width of output voltage

60 °C < Ta m 70 °C 2.5 %/°C static output voltage deviaton 25-100 % < 1%, class C

dynamical 0-100 % < 2%, class A

change of input voltage within < 1 ms, class A the rated input voltage

Recovery time TA Starting time after applying the supply voltage

< 1 ms, class A < 500 ms, class C

Rise time Residual ripple and switching peaks Parallel connection

< 10 ms
BW = 20 MHz < 120 mVpp, class A yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical

Series connection

yes, max. 2 devices to increase voltage

296

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical data

Type No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection

CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C
U/I characteristic curve with power reserve continuous shortcircuit stability current limiting  35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart

No-load protection Starting of capacitive loads Signaling outputs OUTPUT OK signaling output Type of output ON (contact closed) OFF (contact open) Contact ratings

continuous no-load stability yes
13-14 relay, n/o contact 92 % adjusted Uout 90 % adjusted Uout
max. switching voltage / current 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load) min. switching voltage / current 5 V DC / 1 mA

POWER RESERVE signaling output Type of output Active / ON (closed) Inactive / OFF (open) Ratings General data

I > IR transistor, short-circuit proof I > IR I  IR
voltage/current 24 V DC /  20 mA

Efficiency Power loss
Duty cycle MTBF Dimensions Material of housing
Mounting Mounting position Minimum distance to other units
Degree of protection (IEC/EN 60529) Protection class (IEC/EN 61140) Electrical connection

at rated output power up to 93 % at rated output power 12 W at 50% of rated output power 8 W
at no load < 3.6 W 100 %
acc. to MIL 217 HDBK on request see "Dimensional drawings"
cover zinc-coated sheet-steel housing shell aluminium
front plastic, PA6, V-0 DIN rail (IEC/EN 60715), snap-on mounting see "Mounting positions" in the data sheet
horizontal 25 mm (0.98 in) vertical 25 mm (0.98 in)
housing / terminals IP20 / IP20 I

Input circuits (L(+), N(-), PE) Connecting capacity
Stripping length Tightening torque Recommended screw driver Output circuits (L+, L+, L-, L-) Connecting capacity
Stripping length Tightening torque Recommended screw driver

rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)
8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm
rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)
8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

297

-- CP-C.1 range Technical data

Type

CP-C.1 24/5.0, CP-C.1 24/5.0-L

Signaling output (13-14, I > IR)

Connecting capacity

rigid 0.5-4.0 mm² (20-10 AWG)

fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)

Stripping length

8 mm (0.315 in)

Tightening torque

0.5 Nm (4.4 lb.in)

Recommended screw driver

PH1 / Ø 4.0 x 0.8 mm

Maximum cable length (applicable for I>IR)

30 m

Environmental data

CP-C.1 24/5.0-C

Ambient temperature range

operation -25...+70 °C (-13... +158 °F)

-40...+70 °C (-40...+158 °F)

rated output power -25...+60 °C (-13... +140 °F)

-40...+60 °C (-40...+140 °F)

storage -40...+85 °C (-40...+185 °F)

transportation -40...+85 °C (-40...+185 °F)

Climatic class (IEC/EN 60721-3-1)

storage 1K2 (-40...+85 °C / -40...+185 °F)

Climatic class (IEC/EN 60721-3-2)

transportation 2K2 (-40...+85 °C / -40...+185 °F)

Climatic class (IEC/EN 60721-3-3)

operation 3K3 (-25...+70 °C / -13...+158 °F) 3K3 (-40...+70 °C / -40...+158 °F)

Damp heat, cyclic (IEC/EN 60068230)

test Db: 55 °C, 2 cycles

Vibration (IEC/EN 6006826)

test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis

Shock, halfsine (IEC/EN 60068227)

test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis

Coated PCBA

no

yes

Gaseous corrosive environment withstand test (IEC/EN 60068-2-60)

-

testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S  100 ± 10 ppb - SO2/SO3  300 ± 20 ppb - Cl2  100 ± 10 ppb - NOx  1250 ± 20 ppb

Isolation data

Rated impulse withstand voltage Uimp (EN 50178)
Rated insulation voltage Ui (EN 50178)
Overvoltage category (EN 50178) Overvoltage category (IEC/EN 60950-1) Pollution degree Protective separation (IEC/EN 60950-1)

input circuit / output circuit 4 kV (1.2/50 µs) input circuit / PE 4 kV (1.2/50 µs)
input circuit / relay contact 4 kV (1.2/50 µs) output circuit / relay contact 0.5 kV (1.2/50 µs)
relay contact / PE 0.5 kV (1.2/50 µs) output circuit / PE 0.5 kV (1.2/50 µs) input circuit / output circuit 300 V
input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V
relay contact / PE 50 V output circuit / PE 50 V
< 2000 m III 2000...5000 m II
< 2000 m II 2000...5000 m I
2 input circuit / output circuit yes input circuit / relay contact yes

298

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical data

Type Standards / Directives
Standards Low Voltage Directive EMC Directive ATEX Directive RoHS Directive Electrical safety Industrial control equipment Electronic equipment for use in power installations Protective extra low voltage Safety extra low voltage Limitation of harmonic line currents Electromagnetic compatibility Low-voltage power supplies, d.c. output ­ Part 3: Electromagnetic compatibility (EMC)
Interference immunity to electrostatic discharge (ESD) radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge
conducted disturbances, induced by radio-frequency fields
voltage dips, short interruptions and voltage variations harmonics and interharmonics conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
Interference emission limits for harmonic current emissions limitation of voltage changes etc. Information technology equipment radio disturbance characteristics limits and methods of measurement
Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement Voltage sags Federal Communications Commission

CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C

IEC/EN 61204 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 60950-1 UL 508 / CSA 22.2 No 107.1 EN 50178 PELV (EN 50178) SELV (IEC/EN 60950-1) IEC/EN 61000-3-2

2014/34/EU

IEC/EN 61204-3
IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4, 8 kV / 15 kV (criterion A) IEC/EN 61000-4-3 level 3, 10 V/m (criterion A) IEC/EN 61000-4-4 level 4, 4 kV / 2 kV (criterion A) IEC/EN 61000-4-5 level 4, L/N 2 kV (criterion A)
level 4, L,N/PE 4 kV ( criterion A) IEC/EN 61000-4-6 level 3, 10 V (criterion A)
IEC/EN 61000-4-11 class 3 IEC/EN 61000-4-13 class 3 (criterion A) IEC/EN 61000-4-16 level 3, 10 V
IEC/EN 61000-6-3 IEC/EN 61000-3-2 class A IEC/EN 61000-3-3 compliant
IEC/CISPR 22, class B EN 55022
IEC/CISPR 11, class B EN 55011
SEMI F47 passed FCC15 compliant

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

299

-- CP-C.1 range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C

Input circuit - Supply circuit

L (+), N (-)

Rated input voltage Uin Input voltage range

100-240 V AC, 90-300 V DC AC 85-264 V AC

DC 90-300 V DC

Typical input current

at 115 V AC 2.3 A

at 230 V AC 1.2 A

Typical power consumption

at 230 V AC 256 W

Rated frequency

DC, 50/60 Hz

Frequency range

AC 45-65 Hz

Inrush current, cold state

< 11 A

Let-through energy I2t , cold state

at 230 V AC < 1,5 A²s

Discharge current towards PE

< 3.5 mA

Hold-up time

at 115 V AC min. 40 ms

at 230 V AC min. 40 ms

Internal input fuse

T6.3 A, not exchangeable

Recommended backup fuse for wire protection at 1.5 mm2

1 pole miniature circuit breaker ABB type S 200 characteristic B or C

max. rating 16 A

Power factor correction (PFC)

yes, active

Transient overvoltage protection

yes, varistor

User interface

Indication of operational states

Output voltage

LED `OUTPUT OK ` (green)

Power reserve Output circuit - Power output

LED `I > IR' (yellow)

ON flashing
OFF ON

92 % adjusted Uout 90 % adjusted Uout I  IR I > IR

L+, L-

Rated output voltage

24V DC

Tolerance of the output voltage

±1%

Adjustment range of the output voltage

22.5-28.5 V DC

Rated output power

240W

Rated output current IR Reserve output current Short-circuit current limiting

- 25 °C m Ta m 60°C - 40 °C m Ta m 60°C - 25 °C m Ta m 40 °C - 40 °C m Ta m 60°C

10.0A 15.0A continuously 15.5 A

10.0A 15.0 A continuously 15.5 A

Derating of the output current Deviation width of output voltage

60 °C < Ta m 70 °C 2.5 %/°C static output voltage deviation 25-100 % < 1%, class C

2.5 %/°C

dynamic 0-100 % < 5 %, class B

change of input voltage within the rated < 1 ms, class A input voltage

Recovery time TA Starting time after applying the supply voltage Rise time Residual ripple and switching peaks Parallel connection

< 1 ms, class A < 500 ms, class C < 10 ms BW = 20 MHz < 120 mVpp, class A yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical

Series connection

yes, max. 2 devices to increase voltage

300

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical data

Type No-load, overload and short-circuit behavior Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection

CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C
U/I characteristic curve with power reserve continuous shortcircuit stability current limiting  35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart

No-load protection Starting of capacitive loads Signaling outputs

continuous no-load stability yes

OUTPUT OK signaling output

Type of output ON (contact closed) OFF (contact open) Contact ratings

13-14 relay, n/o contact 92 % adjusted Uout 90 % adjusted Uout
max. switching voltage / current 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load) min. switching voltage / current 5 V DC / 1 mA

POWER RESERVE signaling output Type of output Active / ON (closed) Inactive / OFF (open) Ratings General data

I > IR voltage/current

transistor, short-circuit proof
I > IR I  IR 24 V DC /  20 mA

Efficiency Power loss
Duty cycle MTBF Dimensions Material of housing
Mounting Mounting position Minimum distance to other units
Degree of protection (IEC/EN 60529) Protection class (IEC/EN 61140) Electrical connection Input circuits (L(+), N(-), PE)

at rated output power up to 94 % at rated output power 16 W at 50% of rated output power 12 W
at no load < 3.6 W 100 %
acc. to MIL 217 HDBK on request see "Dimensional drawings"
cover zinc-coated sheet-steel housing shell aluminium
front plastic, PA6, V-0 DIN rail (IEC/EN 60715), snap-on mounting see "Mounting positions" in the data sheet
horizontal 25 mm (0.98 in) vertical 25 mm (0.98 in)
housing / terminals IP20 / IP20 I

Connecting capacity
Stripping length Tightening torque Recommended screw driver

rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)
8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm

Output circuits (L+, L+, L-, L-) Connecting capacity
Stripping length Tightening torque Recommended screw driver

rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)
8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

301

-- CP-C.1 range Technical data

Type Signaling output (13-14, I > IR) Connecting capacity
Stripping length Tightening torque Recommended screw driver Maximum cable length (applicable for I>IR) Environmental data

CP-C.1 24/10.0, CP-C.1 24/10.0-L
rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)
8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm 30 m

CP-C.1 24/10.0-C

Ambient temperature range
Climatic class (IEC/EN 60721-3-1) Climatic class (IEC/EN 60721-3-2) Climatic class (IEC/EN 60721-3-3)

operation -25...+70 °C (-13...+158 °F) rated output power -25...+60 °C (-13...+140 °F)
storage -40...+85 °C (-40...+185 °F) transportation -40...+85 °C (-40...+185 °F)
storage 1K2 (-40...+85 °C / -40...+185 °F) transportation 2K2 (-40...+85 °C / -40...+185 °F)
operation 3K3 (-25...+70 °C / -13...+158 °F)

-40...+70 °C (-40...+158 °F) -40...+60 °C (-40...+140 °F)
3K3 (-40...+70 °C / -40...+158 °F)

Damp heat, cyclic (IEC/EN 60068230) Vibration (IEC/EN 6006826)

test Db: 55 °C, 2 cycles
test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis

Shock, halfsine (IEC/EN 60068227)

test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis

Coated PCBA

no

Gaseous corrosive environment withstand test (IEC/EN 60068-2-60)

-

Isolation data

yes
testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S  100 ± 10 ppb - SO2/SO3  300 ± 20 ppb - Cl2  100 ± 10 ppb - NOx  1250 ± 20 ppb

Rated impulse withstand voltage Uimp (EN 50178)
Rated insulation voltage Ui (EN 50178)
Overvoltage category (EN 50178) Overvoltage category (IEC/EN 60950-1) Pollution degree Protective separation (IEC/EN 60950-1)

input circuit / output circuit 4 kV (1.2/50 µs) input circuit / PE 4 kV (1.2/50 µs)
input circuit / relay contact 4 kV (1.2/50 µs) output circuit / relay contact 0.5 kV (1.2/50 µs)
relay contact / PE 0.5 kV (1.2/50 µs) output circuit / PE 0.5 kV (1.2/50 µs) input circuit / output circuit 300 V
input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V
relay contact / PE 50 V output circuit / PE 50 V
< 2000 m III 2000...5000 m II
< 2000 m II 2000...5000 m I
2 input circuit / output circuit yes input circuit / relay contact yes

302

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical data

Type
Standards / Directives
Standards Low Voltage Directive EMC Directive ATEX Directive RoHS Directive Electrical safety Industrial control equipment / General Use Power Supplies Electronic equipment for use in power installations Protective extra low voltage Safety extra low voltage Limitation of harmonic line currents Electromagnetic compatibility
Low-voltage power supplies, d.c. output ­ Part 3: Electromagnetic compatibility (EMC) Interference immunity to
electrostatic discharge (ESD) radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge
conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz Interference emission limits for harmonic current emissions limitation of voltage changes etc. Information technology equipment radio disturbance characteristics limits and methods of measurement Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement Voltage sags Federal Communications Commission

CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C

IEC/EN 61204 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 60950-1 UL 508 / CSA 22.2 No 107.1 EN 50178 PELV (EN 50178) SELV (IEC/EN 60950-1) IEC/EN 61000-3-2

2014/34/EU

IEC/EN 61204-3
IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4, 8 kV / 15 kV (criterion A) IEC/EN 61000-4-3 level 3, 10 V/m (criterion A) IEC/EN 61000-4-4 level 4, 4 kV / 2 kV (criterion A) IEC/EN 61000-4-5 level 4, L/N 2 kV (criterion A)
level 4, L,N/PE 4 kV (criterion A) IEC/EN 61000-4-6 level 3, 10 V (criterion A) IEC/EN 61000-4-11 class 3 IEC/EN 61000-4-13 class 3 (Criterion A) IEC/EN 61000-4-16 level 3, 10 V
IEC/EN 61000-6-3 IEC/EN 61000-3-2 class A IEC/EN 61000-3-3 compliant
IEC/CISPR 22, class B EN 55022
IEC/CISPR 11, class B EN 55011
SEMI F47 passed FCC15 compliant

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

303

-- CP-C.1 range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C

Input circuit - Supply circuit

L (+), N (-)

Rated input voltage Uin Input voltage range

100-240 V AC, 90-300 V DC AC 85-264 V AC

DC 90-300 V DC

Typical input current

at 115 V AC 4.6 A

at 230 V AC 2.3 A

Typical power consumption

at 230 V AC 508 W

Rated frequency

DC, 50/60 Hz

Frequency range

AC 45-65 Hz

Inrush current, cold state

< 11 A

Let-through energy I2t , cold state

at 230 V AC < 3 A2s

Discharge current towards PE

< 3.5 mA

Hold-up time

at 115 V AC min. 40 ms

at 230 V AC min. 40 ms

Internal input fuse

T12 A, not exchangeable

Recommended backup fuse for wire protection at 1.5 mm2

1 pole miniature circuit breaker ABB type S 200 characteristic B or C

max. rating 16 A

Power factor correction (PFC)

yes, active

Transient overvoltage protection

yes, varistor

User interface

Indication of operational states

Output voltage

LED `OUTPUT OK ` (green)

Power reserve Output circuit - Power output

LED `I > IR' (yellow)

ON flashing
OFF ON

92 % adjusted Uout 90 % adjusted Uout I  IR I > IR

L+, L-

Rated output voltage

24V DC

Tolerance of the output voltage

± 1%

Adjustment range of the output voltage

22.5-28.5 V DC

Rated output power

480 W

Rated output current IR Reserve output current Short-circuit current limiting

- 25 °C m Ta m 60°C 20 A - 40 °C m Ta m 60°C - 25 °C m Ta m 40 °C 26.0 A continuously - 40 °C m Ta m 60°C -
27.7 A

20 A 26.0 A continuously

Derating of the output current Deviation width of output voltage

60 °C < Ta m 70 °C 2.5 %/°C static output voltage deviaton 25-100 % < 1 %, class C

dynamical 0-100 % < 5 %, class B

change of input voltage within the rated < 5 ms, class B input voltage

Recovery time TA Starting time after applying the supply voltage Rise time Residual ripple and switching peaks Parallel connection

< 1 ms, class A < 500 ms, class C < 10 ms BW = 20 MHz < 120 mVpp, class A yes, up to 5 devices, to enable redundancy and to increase power, current not symmetrical

Series connection

yes, max. 2 devices to increase voltage

304

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical data

Type No-load, overload and short-circuit behavior

CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C

Characteristic curve of output Short-circuit protection Short-circuit behavior Resistance to reverse feed Overload protection Overtemperature protection
No-load protection Starting of capacitive loads Signaling outputs

U/I characteristic curve with power reserve continuous shortcircuit stability current limiting  35 V DC constant current limitation protection by switch off in case of overtemperature (thermal protection), automatic restart continuous no-load stability yes

OUTPUT OK signaling output Type of output

13-14 relay, n/o contact

ON (contact closed) OFF (contact open) Contact ratings

max. switching voltage / current

92 % adjusted Uout 90 % adjusted Uout 30 V AC - 0.5 A / 24 V DC - 1 A (resistive load)

min. switching voltage / current 5 V DC / 1 mA

POWER RESERVE signaling output Type of output Active / ON (closed) Inactive / OFF (open) Ratings General data Efficiency Power loss
Duty cycle MTBF Dimensions Material of housing
Mounting Mounting position Minimum distance to other units
Degree of protection (IEC/EN 60529) Protection class (IEC/EN 61140) Electrical connection Input circuits (L(+), N(-), PE) Connecting capacity
Stripping length Tightening torque Recommended screw driver

I > IR voltage/current

transistor, short-circuit proof I > IR I  IR 24 V DC /  20 mA

at rated output power at rated output power at 50 % of rated output power
at no load
acc. to MIL 217 HDBK
cover housing shell
front
horizontal vertical
housing / terminals

up to 94 % 28 W 17 W < 3.6 W 100 % on request see "Dimensional drawings" zinc-coated sheet-steel aluminium plastic, PA6, V-0 DIN rail (IEC/EN 60715), snap-on mounting see "Mounting positions" in the data sheet 25 mm (0.98 in) 25 mm (0.98 in) IP20 / IP20 I

rigid 0.5-4.0 mm² (20-10 AWG) fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)
8 mm (0.315 in) 0.5 Nm (4.4 lb.in) PH1 / Ø 4.0 x 0.8 mm

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

305

-- CP-C.1 range Technical data

Type

CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C

Output circuits (L+, L+, L-, L-)

Connecting capacity
Stripping length Tightening torque Recommended screw driver Signaling output (13-14, I > IR) Connecting capacity

rigid fine-strand with(out) wire end ferrule

2.5-16.0 mm² (12-6 AWG) 2.5-10 mm² (12-8 AWG) 10 mm ( 0.394 in) 1.2 Nm (10.5 lb-in) PH1 / Ø 4.0 x 0.8 mm

rigid 0.5-4.0 mm² (20-10 AWG)

fine-strand with(out) wire end ferrule 0.5-2.5 mm² (20-12 AWG)

Stripping length

8 mm (0.315 in)

Tightening torque

0.5 Nm (4.4 lb.in)

Recommended screw driver

PH1 / Ø 4.0 x 0.8 mm

Maximum cable length (applicable for I>IR) Environmental data

30 m

Ambient temperature range
Climatic class (IEC/EN 60721-3-1) Climatic class (IEC/EN 60721-3-2) Climatic class (IEC/EN 60721-3-3)

operation rated output power
storage transportation
storage transportation
operation

Damp heat, cyclic (IEC/EN 60068230) Vibration (IEC/EN 6006826)

Shock, halfsine (IEC/EN 60068227)

Coated PCBA Gaseous corrosive environment withstand test (IEC/EN 60068-2-60)

-25...+70 °C (-13...+158 °F)

-40...+70 °C (-40...+158 °F)

-25...+60 °C (-13...+140 °F)

-40...+60 °C (-40...+140 °F)

-40...+85 °C (-40...+185 °F)

-40...+85 °C (-40...+185 °F)

1K2 (-40...+85 °C / -40...+185 °F)

2K2 (-40...+85 °C / -40...+185 °F)

3K3 (-25...+70 °C / -13...+158 °F)

3K3 (-40...+70 °C / -40... +158 °F)

test Db: 55 °C, 2 cycles

test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis

test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis

no

yes

-

testing method: 4

testing period: 21 days

ambient conditions: 25 °C,

75 % r.h.

air/volume change rate per

hour: 3-6

sample not energized

during exposure

gas concentrations

acc. ISA-S71.04.2013 Harsh

Group A, G3

IEC 60721-3.3 acc. 3C2/3C3

- H2S  100 ± 10 ppb

- SO2/SO3  300 ± 20 ppb

- Cl2  100 ± 10 ppb

- NOx  1250 ± 20 ppb

306

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical data

Type Isolation data Rated impulse withstand voltage Uimp (EN 50178)
Rated insulation voltage Ui (EN 50178)
Overvoltage category (EN 50178) Overvoltage category (IEC/EN 60950-1) Pollution degree Protective separation (IEC/EN 60950-1) Standards / Directives

CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C
input circuit / output circuit 4 kV (1.2/50 µs) input circuit / PE 4 kV (1.2/50 µs)
input circuit / relay contact 4 kV (1.2/50 µs) output circuit / relay contact 0.5 kV (1.2/50 µs)
relay contact / PE 0.5 kV (1.2/50 µs) output circuit / PE 0.5 kV (1.2/50 µs) input circuit / output circuit 300 V
input circuit / PE 300 V input circuit / relay contact 300 V output circuit / relay contact 50 V
relay contact / PE 50 V output circuit / PE 50 V
< 2000 m III 2000...5000 m II
< 2000 m II 2000...5000 m I
2 input circuit / output circuit yes input circuit / relay contact yes

Standards Low Voltage Directive EMC Directive ATEX Directive RoHS Directive Electrical safety Industrial control equipment / General Use Power Supplies Electronic equipment for use in power installations Protective extra low voltage Safety extra low voltage Limitation of harmonic line currents Electromagnetic compatibility

IEC/EN 61204 2014/35/EU 2014/30/EU 2011/65/EU IEC/EN 60950-1 UL 508 / CSA 22.2 No 107.1 EN 50178 PELV (EN 50178) SELV (IEC/EN 60950-1) IEC/EN 61000-3-2

2014/34/EU

Low-voltage power supplies, d.c. output ­ Part 3: Electromagnetic compatibility (EMC)

IEC/EN 61204-3

Interference immunity to electrostatic discharge (ESD) radiated, radio-frequency, electromagnetic field electrical fast transient / burst surge

IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 4, 8 kV / 15 kV (criterion A) IEC/EN 61000-4-3 level 3, 10 V/m (criterion A) IEC/EN 61000-4-4 level 4, 4 kV / 2 kV (criterion A) IEC/EN 61000-4-5 level 4, L/N 2 kV (criterion A)
level 4, L,N/PE 4 kV (criterion A)

conducted disturbances, induced by radio-frequency fields voltage dips, short interruptions and voltage variations harmonics and interharmonics conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz

IEC/EN 61000-4-6 level 3, 10 V (criterion A) IEC/EN 61000-4-11 class 3 IEC/EN 61000-4-13 class 3 (Criterion A) IEC/EN 61000-4-16 level 3, 10 V

Interference emission limits for harmonic current emissions limitation of voltage changes etc. Information technology equipment radio disturbance characteristics limits and methods of measurement

IEC/EN 61000-6-3 IEC/EN 61000-3-2 class A IEC/EN 61000-3-3 compliant
IEC/CISPR 22, class B EN 55022

Industrial scientific and medical (ISM) radio-frequency equipment electromagnetic disturbance characteristics limits and methods of measurement
Voltage sags
Federal Communications Commission

IEC/CISPR 11, class B EN 55011
SEMI F47 passed FCC15 compliant

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

307

-- CP-C.1 range Technical diagrams

2CDC 272 027 F0215

-- CP-C.1 24/5.0 , CP-C.1 24/5.0-L and CP-C.1 24/5.0-C

Efficiency [%]
95.0
90.0
85.0
80.0
75.0 0 1 2 3 4 5 6 7 8 Iout [A]
Typical efficiency over output current

2CDC 272 023 F0215

Efficiency [%]

94.0

93.0

92.0

91.0

90.0

89.0 85 110 130 150 170 190 210
Typical efficiency over AC input voltage

230 250 Uin [VAC]

Power loss [W] 15

Power loss [W] 15

2CDC 272 025 F0215

Efficiency [%] 93.0
92.5

at 150% load at 100% load

92.0

91.5

91.0 -25 -15 -5 5 15 25 35 45 55 65 Ta [°C]
Typical efficiency over ambient temperature

10

10

2CDC 272 024 F0215

5

5

2CDC 272 026 F0215

0 85 110 130 150 170 190 210 230 250 Uin [VAC]
Typical power loss over AC input voltage

0 0 1 2 3 4 5 6 7 8 Iout [A]
Typical power loss over output current

-- CP-C.1 24/10.0, CP-C.1 24/10.0 -L and CP-C.1 24/10.0-C

Efficiency [%]

95.0

90.0

85.0 0 2 4 6 8 10 12
Typical efficiency over output current

14 Iout [A]

2CDC 272 007 F0215

Efficiency [%]

94.5

94.0

93.5

93.0

92.5

92.0 85 110 130 150 170 190 210
Typical efficiency over AC input voltage

230 250 Uin [VAC]

Power loss [W] 25

20

15

10

5

0 85

110 130 150 170 190 210 230 250 Uin [VAC]

Typical power loss over AC input voltage

2CDC 272 010 F0215

Power loss [W] 25 20 15 10 5 0 0 2 4 6 8 10 12 14 Iout [A]
Typical power loss over output current

2CDC 272 008 F0215

2CDC 272 009 F0215

Efficiency [%] 94.5 94.0

at 100% load at 150% load

93.5

93.0

92.5

92.0 -25 -15 -5

5 15 25 35 45 55 65 Ta [°C]

Typical efficiency over ambient temperature

2CDC 272 011 F0215

308

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical diagrams

2CDC 272 008 F0216

-- CP-C.1 24/20.0, CP-C.1 24/20.0-L and CP-C.1 24/20.0-C

Efficiency [%]

95.0

90.0

85.0

80.0

5

10

15

20

25 Iout [A]

Typical efficiency over output current

2CDC 272 003 F0216

Efficiency [%]

94.5

94.0

93.5

93.0

92.5

92.0

91.5 85

110 130 150 170 190 210 230 250 Uin [VAC]

Typical efficiency over AC input voltage

2CDC 272 006 F0216

Efficiency [%] 94.5 94.0

at 100% load at 130% load

93.5

93.0

92.5

92.0 -25 -15 -5 5 15 25 35 45 55 65 Ta [°C]
Typical efficiency over ambient temperature

2CDC 272 005 F0216

Power loss [W] 40

35

30

25 85

110 130 150 170 190 210 230 250 Uin [VAC]

Typical power loss over AC input voltage

2CDC 272 007 F0216

Power loss [W] 40

30 20

10

0 04

8

12 16

20

24 Iout [A]

Typical power loss over output current

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

309

-- CP-C.1 range Technical diagrams

2CDC 272 019 F0015

-- Characteristic curve of output at Ta = 25 °C

30

25

Output voltage [ V ]

20

15

10

5

0 0

123456

Output current [A]

at 24 V

at 22.5 V

789 at 28.5 V

CP-C.1 24/5.0, CP-C.1 24/5.0-L CP-C.1 24/5.0-C

2CDC 272 017 F0015
Output voltage [ V ]

30

25

20

15

10

5

0 0

2 4 6 8 10 12 14 16 18

Output current [A]

at 24 V

at 22.5 V

at 28.5 V

CP-C.1 24/10.0, CP-C.1 24/10.0-L CP-C.1 24/10.0-C

-- Characteristic curve of temperature at Uout = 24 V

Output current [A]

8 7 6 5
IR 4 3 2 1 0
-25

Power reserve
-10 0 10 20 30 40 50 60 70 Ambient temperature [°C]

CP-C.1 24/5.0, CP-C.1 24/5.0-L

2CDC 272 020 F0015
Output current [A]

16 14 12 10
IR 8 6 4 2 0
-25

Power reserve
-10 0 10 20 30 40 50 60 70 Ambient temperature [°C]

CP-C.1 24/10.0, CP-C.1 24/10.0-L

2CDC 272 002 F0216
Output current [A]

2CDC 272 018 F0015
Output voltage [ V ]

30

25

20

15

10

5

0 0

4 8 12 16 20 24 28 32 34

Output current [A]

at 24 V

at 22.5 V

at 28.5 V

CP-C.1 24/20.0, CP-C.1 24/20.0-L CP-C.1 24/20.0-C

32 28 24 20
IR 16 12
8 4 0
-25

Power reserve
-10 0 10 20 30 40 50 60 70 Ambient temperature [°C]

CP-C.1 24/20.0, CP-C.1 24/20.0-L

Output current [A]

8

7

6

Power reserve

5 IR
4

3

2

1

0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C]

CP-C.1 24/5.0-C

2CDC 272 014 F0216 Output current [A]

16

14

12

Power reserve

10 IR
8

6

4

2

0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C]

CP-C.1 24/10.0-C

2CDC 272 015 F0216 Output current [A]

32

28

24
20 IR
16

Power reserve

12

8

4

0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C]

CP-C.1 24/20.0-C

2CDC 272 012 F0216

2CDC 272 013 F0216

310

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-C.1 range Technical diagrams

-- Dimensional drawings Dimensions in mm, inches
129.8 5.11" 126.8 4.99"
136.0 5.35"

40.00 1.57"

IEC/EN 60715 TH 35-7.5 TH 35-15

13 14 I > IR
L+ L+ L- L-
OUTPUT 24 V DC 5 A
CP-C.1 24/5.0
OUTPUT OK POWER RESERVE I > IR

OUTPUT Adjust 22.5-28.5 V

L

L+

L+

L-

N

PWM

L-

INPUT 100-240 V AC L(+) N(-)
CP-C.1 24/5.0

60.00 2.36"

L+ L+ L- L- 13 14 I > IR OUTPUT 24 V DC 10 A

CP-C.1 24/10.0
OUTPUT OK POWER RESERVE I > IR

OUTPUT Adjust 22.5-28.5 V

L

L+

L+

L-

N

PWM

L-

INPUT 100-240 V AC L(+) N(-)
CP-C.1 24/10.0

82.00 3.23"

L+ L+ L- L- 13 14 I > IR OUTPUT 24 V DC 20 A
CP-C.1 24/20.0
OUTPUT OK POWER RESERVE I > IR

OUTPUT Adjust 22.5-28.5 V

L

L+

L+

L-

N

PWM

L-

INPUT 100-240 V AC L(+) N(-)
CP-C.1 24/20.0

129.4 5.09" 129.4 5.09" 129.4 5.09"
2CDC 272 012 F0017

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

311

312

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

313

-- Power supplies for building applications Table of contents

314

CP-D range

314

Benefits and advantages

316

Operation controls

317

Applications

318

Ordering details

319

Technical data

323

Technical diagrams

314

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-D range Benefits and advantages

Thanks to its compact modular housing, the CP-D range is ideal for building applications and installation. For maximum flexibility in operation, six different versions are available, from 10 W up to 100 W. Their wide input voltage range allows their use in global applications.

Easy to install

The CP-D range is easy to adjust and ideally suited for installation in distribution panels due to its width being only 18 to 90 mm.

Global availability

The product can be used in any installation in the world. Giving you the confidence of worldwide sourcing ­ no matter where you build, install or operate your equipment.

Speed up your projects

Data available for common planning software: Less engineering time required.

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

315

-- CP-D range Benefits and advantages

Characteristics · Output voltages 12 V, 24 V DC · Adjustable output voltages (devices > 10 W) · Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A · Power range 10 W, 25 W, 30 W, 60 W, 100 W · Wide range input 100-240 V AC (90-264 V AC, 120-375 V DC) · High efficiency of up to 89 % · Low power dissipation and low heating · Free convection cooling (no forced cooling with ventilators) · Ambient temperature range during operation -40...+70 °C · Open-circuit, overload and short-circuit stable · Integrated input fuse · LEDs for status indication · Light-grey housing in RAL 7035 · Various approvals and marks

Main benefits
Adjustable output voltage The CP-D range types > 10 W feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, for example compensating the voltage drop caused by a long line length.

Wide range input Optimized for world-wide applications: The CP-D power supplies can be supplied with 90-264 V AC or 120-375 V DC.

Width and structural form With their width being only 18 to 90 mm, the CP-D range switch mode power supplies are ideally suited for installation in distribution panels.

316

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-D range Operation controls

OUTPUT ++/: terminals  output 12 V, 24 V

OUTPUT Adjust: potentiometer  adjustment of output voltage*)

Indication of operational states DC ON: green LED  output voltage applied DC LOW: red LED  output voltage too low
*) only for devices > 10 W. 12 V version: 12...14 V DC, 24 V version: 24 ... 28 V DC.

Circuit diagram
INPUT L, N: terminals  input 90 ... 264 V AC 120 ... 375 V DC

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

317

-- CP-D range Applications

Emergency lighting

Communication

Escalators

Elevators

LED lighting

Venetian blind drives

318

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-D range Ordering details

CP-D 12/0.83, CP-D 24/0.42 CP-D 12/2.1, CP-D 24/1.3

2CDC 271 024 F0007

2CDC 271 025 F0007

Description The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution panels. This range offers devices with output voltages of 12 V DC and 24 V DC at output currents of 0.42 A to 4.2 A. Thanks to their high thermal efficiency, these power supplies have very low power and heat dissipation and can be operated without forced cooling. All power supply units in the CP-D range are approved according to all relevant international standards.

-- Ordering details
Input voltage range
90-264 V AC/ 120-375 V DC

Rated output voltage / current
12 V DC / 0.83 A

Type CP-D 12/0.83

90-264 V AC/ 120-375 V DC 12 V DC / 2.1 A

CP-D 12/2.1

90-264 V AC/ 120-375 V DC 24 V DC / 0.42 A

CP-D 24/0.42

90-264 V AC/ 120-375 V DC 24 V DC / 1.3 A

CP-D 24/1.3

90-264 V AC/ 120-375 V DC 24 V DC / 2.5 A

CP-D 24/2.5

90-264 V AC/ 120-375 V DC 24 V DC / 4.2 A

CP-D 24/4.2

Order code
1SVR427041R1000 1SVR427043R1200 1SVR427041R0000 1SVR427043R0100 1SVR427044R0200 1SVR427045R0400

Weight (1 pc.) kg (lb)
0.06 (0.13)
0.19 (0.41)
0.06 (0.13)
0.19 (0.41)
0.25 (0.56)
0.32 (0.71)

2CDC 271 028 F0007

CP-D 24/2.5

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

319

-- CP-D range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-D 12/0.83

Input circuit - supply circuit

L, N

Rated input voltage Uin Input voltage range

100-240 V AC 90-264 V AC / 120-375 V DC

Frequency range AC

47-63 Hz

Typical input current / typical power consumption

at 115 V AC 200 mA / 12.68 W at 230 V AC 128.3 mA / 13.01 W

Inrush current

at 115 / 230 V AC 16 A / 32 A

Power failure buffering time

min. 30 ms

Internal input fuse

1 A slow-acting / 250 V AC

Power factor correction (PFC)

no

Indication of operational states

Output voltage

DC ON: green LED V: output voltage applied

DC LOW: red LED V: output voltage too low

Output circuit

+, -

Rated output voltage

12 V DC

Tolerance of the output voltage

±1 %

Adjustment range of the output voltage

-

Rated output power

10 W

Rated output current Ir

Ta m 60 °C 0.83 A

Derating of the output current

60 °C < Ta m 70 °C 2.5 %/°C

Maximum

load change statical max. 1 %

deviation with

change of output voltage within the input voltage range max. 1 %

CP-D 12/2.1
502 mA / 31.14 W 277 mA / 31.2 W 25 A / 50 A 2 A slow-acting / 250 V AC
++, --
12-14 V DC 25 W 2.1 A

Recover time TA Starting time after applying the supply voltage Rise time

< 1 ms at Ir 1000 ms at rated load typ. 1 ms

Residual ripple and switching peaks

BW = 20 MHz 50 mV

Parallel connection

yes, using CP-D RU

Series connection

yes, to increase voltage

Resistance to reverse feed

18 V / 1 s

Output circuit - No-load, overload and short-circuit behavior

Characteristic curve of output

hiccup-mode

U/I characteristic curve

Short-circuit protection

continuous short-circuit stability

Short-circuit behavior

continuation with output power limiting

Current limiting at short circuit

typ. 1.4 A

typ. 5.9 A

Overload protection

output power limiting

Overvoltage protection

15-16.5 V DC

No-load protection

continuous no-load stability

Starting of capacitive loads

unlimited

General data

Efficiency

typ. 78 %

typ. 82 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

II

320

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-D range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-D 12/0.83

Electrical connection - Input circuit / Output circuit

Connecting capacity

fine-strand with wire end ferrule 0.2-1.5 mm2 (24-16 AWG)

rigid 0.2-2.5 mm2 (26-12 AWG)

Stripping length

4-5 mm (0.16-0.2 in)

Tightening torque

0.6 Nm (5 lb.in)

Environmental data

Ambient temperature range

operation -40...+70 °C (-40...+158 °F)

rated load -40...+60 °C (-40...+131 °F)

storage -40...+85 °C (-40...+185 °F)

Altitude during operation

IEC/EN 60068-2-13 max. 4850 m

Damp heat (cyclic) (IEC/EN 60068-2-30)

4 x 24 cycles, 40 °C, 95 % RH

Vibration (sinusoidal) (IEC/EN 60068-2-6)

50 m/s2, 10 Hz - 2 kHz

Shock (half-sine) (IEC/EN 60068-2-27)

40 m/s2, 22 ms

Isolation data

Rated insulation voltage Ui Pollution degree

input circuit / output circuit 3 kV AC 2

Overvoltage category

ll

Standards / Directives

Standards

IEC/EN 60950-1

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Protective low voltage

SELV (IEC/EN 60950-1)

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 4 (4 kV / 8 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 level 4 (4 kV)

surge

IEC/EN 61000-4-5 level 3 (2 kV L-L)

conducted disturbances, induced by radiofrequency fields

IEC/EN 61000-4-6 level 3 (10 V)

Interference emission high-frequency radiated high-frequency conducted

IEC/EN 61000-6-3 class B class B

CP-D 12/2.1 0.2-2.5 mm2 (24-14 AWG) 0.2-2.5 mm2 (24-12 AWG) 7 mm (0.28 in) 0.7 Nm (6 lb.in)
level 4 (4 kV / 15 kV)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

321

-- CP-D range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-D 24/0.42

CP-D 24/1.3

CP-D 24/2.5

CP-D 24/4.2

Input circuit - supply circuit

L, N

Rated input voltage Uin Input voltage range

100-240 V AC 90-264 V AC /120-375 V DC

Frequency range AC

47-63 Hz

Typical input current / typical power consumption

at 115 V AC 184 mA / 11.62 W 600 mA / 37.92 W 1120 mA / 69.3 W 1800 mA / 117.3 W at 230 V AC 120.6 mA / 12 W 344 mA / 38.16 W 660 mA / 70.1 W 900 mA / 114.4 W

Inrush current

at 115 / 230 V AC max. 16 A / 32 A max. 25 A / 50 A max. 30 A / 60 A

Power failure buffering time

min. 30 ms

min. 60 ms

Internal input fuse

1 A slow-acting / 2 A slow-acting /

250 V AC

250 V AC

3.15 A slowacting / 250 V AC

Power factor correction (PFC) Indication of operational states Output voltage
Output circuit Rated output voltage Tolerance of the output voltage Adjustment range of the output voltage Rated output power Rated output current Ir Derating of the output current

no

DC ON: green LED V: output voltage applied

DC LOW: red LED V: output voltage too low

+, -

24 V DC

±1 %

-

24-28 V DC

10 W

30 W

Ta  60 °C: 0.42 A Ta  60 °C: 1.3 A

60 °C < Ta  70 °C: 60 °C < Ta  70 °C:

2.5 %/°C

2.5 %/°C

++, --
60 W Ta  55 °C: 2.5 A 55 °C < Ta  70 °C: 2.5 %/°C

100 W
Ta  60 °C: 4.2 A 60 °C < Ta  70 °C: 2.5 %/°C

Maximum deviation with

load change statical max. 1 % change of output voltage within the input voltage range max. 1 %

Recover time TA Starting time after applying the supply voltage Rise time

< 1 ms at Ir 1000 ms at rated load typ. 1 ms

Residual ripple and switching peaks

BW = 20 MHz 50 mV

Parallel connection

yes, using CP-D RU

Series connection

yes, to increase voltage

Resistance to reverse feed

35 V / 1 s

Output circuit - No-load, overload and short-circuit behavior

Characteristic curve of output

hiccup-mode

U/I characteristic curve

Short-circuit protection

continuous short-circuit stability

Short-circuit behavior

continuation with output power limiting

Current limiting at short circuit

typ. 0.78 A

typ. 4.2 A

typ. 6.05 A

typ. 11.5 A

Overload protection

output power limiting

Overvoltage protection

30-33 V DC

No-load protection

continuous no-load stability

Starting of capacitive loads

unlimited

General data

Efficiency

typ. 80 %

typ. 83 %

typ. 86 %

typ. 89 %

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting without any tool

Mounting position

horizontal

Minimum distance to other units

horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in)

Degree of protection

housing / terminals IP20 / IP20

Protection class

II

322

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-D range Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-D 24/0.42

CP-D 24/1.3

CP-D 24/2.5

Electrical connection - Input circuit / Output circuit

Connecting capacity

fine-strand with 0.2-1.5 mm2 wire end ferrule (24-16 AWG)

0.2-2.5 mm2 (24-14 AWG)

rigid 0.2-2.5 mm2 (26-12 AWG)

0.2-2.5 mm2 (24-12 AWG)

Stripping length Tightening torque Environmental data Ambient temperature range
Altitude during operation Damp heat (cyclic) (IEC/EN 60068-2-30) Vibration (sinusoidal) (IEC/EN 60068-2-6) Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage Ui Pollution degree Overvoltage category Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Protective low voltage Electromagnetic compatibility Interference immunity to electrostatic discharge

4-5 mm (0.16-0.2 in) 0.6 Nm (5 lb.in)

operation -40...+70 °C rated load -40...+60 °C
storage -40...+85 °C IEC/EN 60068-2-13 max. 4850 m
4 x 24 cycles, 40 °C, 95 % RH 50 m/s2, 10 Hz - 2 kHz 40 m/s2, 22 ms

input circuit / output circuit 3 kV AC 2 ll

IEC/EN 60950-1 2014/35/EU 2014/30/EU 2011/65/EU SELV (IEC/EN 60950-1)

IEC/EN 61000-6-2

IEC/EN 61000-4-2 level 4 (4 kV / 8 kV)

level 4 (4 kV / 15 kV)

7 mm (0.28 in) 0.7 Nm (6 lb.in) -40...+55 °C
4 kV AC

radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radiofrequency fields

IEC/EN 61000-4-3 level 3 (10 V/m) IEC/EN 61000-4-4 level 4 (4 kV) IEC/EN 61000-4-5 level 3 (2 kV L-L) IEC/EN 61000-4-6 level 3 (10 V)

Interference emission high-frequency radiated high-frequency conducted

IEC/EN 61000-6-3 class B class B

CP-D 24/4.2
-40...+60 °C 3 kV AC
level 4 (4 kV / 8 kV)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

323

-- CP-D range Technical diagrams

22CCDDCC27227202002F002F007207

22CCDDCC22727202022F20F2007207

-- Characteristic curve of output at Ta = 25 °C

Uout [V]

12

11

10

9

8

7

6

5

4

3

2

1

0

0

0.25 0.5

0.75

1

CP-D 12/0.83

1.25 Iout [A]

22CCDDCC22772201091F90F2007207

Uout [V] 24 22 20 18 16 14 12 10 8 6 4 2 0
0 0.125 0.25
CP-D 24/0.42

0.375 0.5

0.625 0.75 0.875 Iout [A]

22CCDDCC 227722002121F0F2002707

Uout [V]
12 11 10
9 8 7 6 5 4 3 2 1 0
0 0.5 1 1.5 2 2.5 3 3.5 4 Iout [A]
CP-D 12/2.1

Uout [V]

24

22

20

18

16

14

12

10

8

6

4

2

0

0

0.5 1

CP-D 24/1.3

1.5

2

2.5 3 Iout [A]

Uout [V]

24

22

20

18

16

14

12

10

8

6

4

2

0

0 0.5 1 1.5 2 2.5 3 3.5 4

CP-D 24/2.5

Iout [A]

22CCDCC22772202032F30F2007207

Uout [V]

24

22

20

18

16

14

12

10

8

6

4

2

0

0 1 2 3 45 678

CP-D 24/4.2

Iout [A]

-- Characteristic curve of temperature at rated output voltage
Pout [%]

Pout [%]

100 90 80 70 60 50 40 30 20 10
-10 0 10 20 30 40 50 60 70 Ta [°C]
CP-D except CP-D 24/2.5

2CDC 272 018 F0207 2CDC 272 018 F0207

100 90 80 70 60 50 40 30 20 10
-10 0 10 20 30 40 50 60 70 Ta [°C]
CP-D 24/2.5

2CDC22C72D 0C1287F20200178 F0207

22CCDDCC22772203003F00F2007207

324

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-D range Technical diagrams

-- Dimensional drawings Dimensions in mm

18.0 [0.71"]

67.0 [2.64"] 44.5 [1.75"]

53.0 [2.09"]

67.0 [2.64"] 44.5 [1.75"]

32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"]
22CCDDCC27227021201F20bF007b07

32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"]
22CCDCD 2C72207121 F001b107F0b07 91.0 [3.58"]

91.0 [3.58"]

CP-D 12/0.83, CP-D 24/0.42

71.0 [2.80"]

67.0 [2.64"] 44.5 [1.75"]

91.0 [3.58"]

CP-D 24/2.5

32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"]
22CCDDCC227722001133FF00bb0077 91.0 [3.58"]

CP-D 12/2.1, CP-D 24/1.3

89.9 [3.54"]

67.0 [2.64"] 44.5 [1.75"]

CP-D 24/4.2

32.1 [1.26"] 49.0 [1.93"] 57.5 [2.26"]
22CCDDCC 2272 014 F0b077

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

325

326

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

327

-- CP-B range Table of contents

328

Benefits and advantages

330

Operation controls

331

Applications

332

Ordering details

333

Technical data

336

Technical diagrams

328

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-B range Benefits and advantages

ABB's ultra-capacitor based CP-B buffer modules serve to ensure a short-term uninterrupted power supply system with a voltage of 24 V DC by buffering the load in case of power loss.
The buffer modules feature a technology for storing energy: the use of ultracapacitors obviates the need for maintenance and exempts deep discharge in comparison to batteries.
Energy storage can be expanded with additional extension modules for longer buffering times and is therefore extremely adaptable.

24 7
Continuous operation

· Buffering 24 V DC supply of up to 380 s · Maintenance-free, ultra-capacitor technology · Temperature resistant · No deep charge · Small footprint

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

329

-- CP-B range Benefits and advantages

Power supply systems have to be highly reliable in most areas of energy management and automation technology. Often, batteries are used for supporting the supply system in case of mains failures. Batteries have limited lifetimes depending on environmental parameters and have to be maintained regularly, which causes extra work and costs.
Using the ultra-capacitor technology, ABB offers an innovative and completely maintenance-free new product for buffering the 24 V DC supply in case of interrupted mains on the primary side of the switch mode power supply.
The CP-B range is an ultra-capacitor buffer energy storage system for power supply units which ensures a short term uninterrupted power supply system. In case of power loss, the energy stored in the capacitor guarantees that the load is continually provided for up to several hundred seconds depending on the load current.

Characteristics · 3 buffer modules for buffering 24 V DC:
CP-B 24/3.0 (3 A / 1 kWs1)) CP-B 24/10.0 (10 A / 10 kWs1)) CP-B 24/20.0 (20 A / 8 kWs1)) · CP-B 24/3.0 and CP-B 24/20.0 expandable with additional extension module(s) CP-B EXT.2 (2 kWs1)) · LEDs for status indication · Relay contacts for status messaging · Very high backup times (e.g. with CP-B 24/10.0 up to 8 minutes at 1 A load current) · Short charging times · High efficiency, higher than 90 % · Wide temperature range · DIN rail mountable, compact housing · Extended temperature range -40...60 °C
1) internal energy buffer

Order code Rated input voltage Rated current Energy storage (min.) Typical charging time at load current
Typical buffering time1) at load current

CP-B 24/3.0 1SVR427060R0300 24 V DC 3 A DC 1.000 Ws 100 % 65 s 0 % 56 s 100 % 13 s 50 % 28 s 25 % 66 s 10 % 148 s

energy storage x 0.9
1) buffering time  current x output voltage

CP-B 24/10.0 1SVR427060R1000 24 V DC 10 A DC 10.000 Ws 134 s 82 s 38 s 76 s 140 s 380 s

CP-B 24/20.0 1SVR427060R2000 24 V DC 20 A DC 8.000 Ws 135 s 62 s 15 s 30 s 60 s 150 s

CP-B EXT.2 1SVR427065R0000 ­ 3 A DC 2.000 Ws

330

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-B range Operation controls

Input terminals SHUT-DOWN+, SHUT-DOWN-: Input signal terminals INPUT OK, BUFFER STATUS, FAILURE: Signalling contact ­ terminals L+IN, L-IN: Input voltage terminals

Indication of operational states OPERATION: Buffer module in operation (standby or buffering) INPUT OK: Input voltage applied

Output terminals L+OUT, L-OUT, L-OUT: Output voltage terminals

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

331

-- CP-B range Applications

-- Example of application

L

N

max. 20 A

L+ L-

CP-B 24/10.0 CP-C.1 24/20.0

L+IN L-IN

L+OUT L-OUT
max. 10 A L+

buffered

L-

load 1 ...

load n

L+ unbuffered L-

load 1

...

load n

332

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-B range Ordering details

CP-B 24/3.0 CP-B 24/10.0

2CDC 271 002 S0010

2CDC 271 001 S0010

Description Ultra capacitor based buffer units of the CP-B range offer the highest reliability also in harsh environments. Thanks to their ultra-cap based technology, the units are maintenance free, there will be no deep discharge and these products offer a very wide operational ambient temperature range. CP-B range buffer units are an excellent solution for avoiding voltage drops in solar applications, for example.

-- Ordering details

Rated input voltage 24 V DC

Rated current
3 A DC 10 A DC 20 A DC

Type

Order code

CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0

1SVR427060R0300 1SVR427060R1000 1SVR427060R2000

Weight (1 pc.) kg (lb) 0.59 (1.31)
2.10 (4.63)
2.20 (4.85)

-- Ordering details - Extension unit for CP-B 24/3.0 and CP-B 24/20.0

Rated voltage

Voltage range

Type

Order code

24 V DC

0-26.4 V DC

CP-B EXT.2

1SVR427065R0000

Weight (1 pc.) kg (lb)
1.04 (2.30)

2CDC 271 003 S0010

CP-B 24/20.0

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

333

-- CP-B range Technical data

Type Input circuit - Supply circuit Rated input voltage Uin Input voltage range Minimum charging potential Rated input current Inrush current limiting Transient overvoltage protection

CP-B 24/3.0 L+IN L-IN 24 V DC 23.7-26.4 V DC 23.7 V DC 3 A DC 50 A / 1 ms suppressor diode

CP-B 24/10.0
23.9-27 V DC 23.9 V DC 10 A DC 35 A / 2 ms varistor / suppressor diode

Internal input fuse (apparatus protection, not accessible)

4 A slow acting

15 A (FK2)

Internal fuse capacitors circuit (not accessible)

25 A (FK2)

Kind of input

SHUT-DOWN -

control input

rated voltage -

24 V DC

voltage range -

6-45 V DC

Output circuit

L+OUT L-OUT L-OUT

Rated output power

69 W

240 W

Rated output voltage Uout Output voltage (buffer mode)

24 V DC 23.0 V DC

23.2 V DC

Tolerance of the output voltage

+2...-10 %

Rated output current Ir Peak output current (fully loaded capacitors required)

Ta  60 °C 3 A DC Ta  60 °C 6 A DC (min. 1.5 s)

10 A DC
20 A DC (10 A power supply + 10 A CP-B, min. 1.5 s)

Control of limiting current

-

10.3 A DC w0.1A

Shut-down if limiting current is exceeded

-

after 1.5 s

Short-circuit protection (only via external fuse)

no continuous short-circuit stability

Internal output fuse (not accessible)

-

15 A (FK2)

Required external fuse

3.15 A slow acting

10 A slow acting

Current limiting at output circuit Breaking capacity of output circuit

t= 2.5 ms -

1.05...1.2 x Ir 24 V DC, 10 A

Power failure buffering time 1)

load-dependent, min. load-dependent, min.

13 s at 100 % load

38 s at 100 % load

Overload protection

thermal protection

Kind of output

INPUT OK n/o contact

BUFFER STATUS -

n/o contact

FAILURE -

c/o contact

Contact material

Ag + Au-clad

Minimum switching voltage / Minimum switching current

5 V DC / 1 mA

Maximum switching voltage / Maximum switching current

50 V AC / 1.0 A, 30 V DC / 0.5 A

Mechanical lifetime

5 x 106 switching cycles

Electrical lifetime

0.1 x 106 switching cycles

Maximum fuse rating to achieve short-circuit protection

n/o or n/c 1.0 A AC / 0.5 A DC contact

CP-B 24/20.0
23.4-29 V DC 23.4 V DC 20 A DC 35 A / 2 ms varistor / suppressor diode 30 A (FK2)
control input 24 V DC 6-45 V DC
480 W
23.2 V DC
20 A DC 40 A DC (min. 1.5 s)
-
25 A slow acting load-dependent, min. 15 s at 100 % load

334

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-B range Technical data

Type

CP-B 24/3.0

CP-B 24/10.0

CP-B 24/20.0

General data

Maximum internal power consumption

7 W

20 W

40 W

Power consumption with unloaded output

0.75 W

3 W

1.6 W

Energy storage (min.)

1000 Ws

10000 Ws

8000 Ws

Typical charging time at load current

100 % 65 s

134 s

135 s

0 % 56 s

82 s

62 s

Typical buffering time at load current1)

100 % 13 s

38 s

15 s

50 % 28 s

76 s

30 s

25 % 66 s

140 s

60 s

10 % 148 s

380 s

150 s

Efficiency

> 90 %

Dimensions

see "Dimensional drawings"

Material

cover / housing shell steel sheet powdered

Mounting

DIN rail (IEC/EN 60715), snap-on mounting

Mounting position

horizontal

Minimum distance to other units

horizontal not necessary

vertical 40 mm (1.58 in)

80 mm (3.15 in)

Pollution degree

2

Degree of protection

housing / terminal IP20

Protection class (IEC/EN 61140)

III SELV / PELV (condition: power supply fulfills class III)

Electrical connection - Input circuit / Output circuit

pull spring terminals

pull spring terminals pluggable screw type terminals

Connecting capacity

fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)

0.08-1.5 mm² (28-18 AWG)

0.2-4.0 mm² (24-12 AWG)

rigid 0.08-1.5 mm² (28-16 AWG)

0.08-4.0 mm² (28-16 AWG)

0.2-6.0 mm² (24-10 AWG)

Stripping length Signaling circuit Connecting capacity

6.0 mm (0.24 in) fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)

7.0 mm (0.28 in)
0.14-1.0 mm² (26-16 AWG)

rigid 0.08-1.5 mm² (28-16 AWG)

0.14-1.5 mm² (28-16 AWG)

Stripping length Environmental data Ambient temperature
Standards / Directives Standards Low Voltage Directive EMC Directive RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst surge conducted disturbances, induced by radio-frequency fields

6.0 mm (0.24 in)

7.0 mm (0.28 in)

operation -40...+60 °C storage -40...+60 °C

EN 50178, IEC/EN 60950-1, IEC/EN 62040-2 2014/35/EU 2014/30/EU 2011/65/EC

IEC/EN 61000-6-2 IEC/EN 61000-4-2 level 3, 6 kV / 8 kV IEC/EN 61000-4-3 level 3, 10 V/m (27-1000 MHz) / level 2, 3 V/m (1400-2700 MHz) IEC/EN 61000-4-4 level 3, 2(1) kV / 5 kHz IEC/EN 61000-4-5 level 1, 0.5 kV IEC/EN 61000-4-6 level 3, 10 V (150 kHz-80 MHz)

voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-11 buffered by ultra-capacitors

Interference emission high-frequency radiated high-frequency conducted

EN 61000-6-4 DIN EN 55011 B/C1 DIN EN 55011 B/C1

energy storage x 0.9 1) buffering time 
current x output voltage

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

335

-- CP-B range Technical data

Data at Ta = 25 °C and rated values, unless otherwise indicated

Type

CP-B EXT 2.0

Extension circuit

EXT+ EXT+ EXT- EXT-

Rated voltage

24 V DC

Voltage range

0-26.4 V DC

Rated current

3 A DC

Internal input fuse (apparatus protection, not accessible)

4 A slow acting (PTC)

Short-circuit protection

via internal 3 A fuse

Overload protection

only in combination with CP-B 24/3.0 or CP-B 24/20.0

Indication of operational states

status information and fault messages of the buffer module apply

General data

Power consumption without load

0.5 W

Energy storage (min.)

2000 Ws

Material

cover / housing shell steel sheet powdered

Mounting

DIN rail (IEC/EN 60715), snap-on mounting

Mounting position

horizontal

Minimum distance to other units

horizontal not necessary

vertical 40 mm (1.58 in)

Pollution degree

2

Degree of protection

housing / terminal IP20

Protection class (IEC/EN 61140)

III SELV / PELV (condition: power supply fulfills class III)

Electrical connection - Extension circuit

pull spring terminals

Connecting capacity

fine-strand with(out) wire end ferrule 0.08-1.0 mm² (28-18 AWG)

rigid 0.08-1.5 mm² (28-16 AWG)

Stripping length

6.0 mm (0.24 in)

Environmental data

Ambient temperature

operation -40...+60 °C

storage -40...+60 °C

Vibration, sinusoidal

IEC/EN 60068-2-6 1.5 mm, 3-57.55 Hz; 2 g, 57.55-500 Hz, 10 cycles

Shock, half-sine

IEC/EN 60068-2-27 15 g, 11 ms, 3 axes, 6 faces, 3 times for each face

Standards / Directives

Standards

EN 50178, IEC/EN 60950-1, IEC/EN 62040-2

Low Voltage Directive

2014/35/EU

EMC Directive

2014/30/EU

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 3, 6 kV / 8 kV

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3, 10 V/m (27-1000 MHz) / level 2, 3 V/m (1400-2700 MHz)

electrical fast transient/burst

IEC/EN 61000-4-4 level 3, 2(1) kV / 5 kHz

surge

IEC/EN 61000-4-5 level 1, 0.5 kV

conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-6 level 3, 10 V (150 kHz-80 MHz)

voltage dips, short interruptions and voltage variations

IEC/EN 61000-4-11 buffered by ultra-capacitors

Interference emission

EN 61000-6-4

high-frequency radiated

DIN EN 55011 B/C1

high-frequency conducted

DIN EN 55011 B/C1

336

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- CP-B range Technical diagrams

2CDC 272 031 F0210

-- Characteristic curve of the temperature at rated load
Iout [A]
A
3.0
B
1.5

-40 0
CP-B 24/3.0
Iout [A]

20 40 60

10.0 7.5 5.0

Ta [°C]
A B

2CDC 272 028 F0210

Years

-- Capacitors life span over temperature
60
50
40
30
20
10
0 10 20 30 40 50 60 70 Temperature [°C]

2CDC 272 029 F0210

-40 0
CP-B 24/10.0
Iout [A]

20 40 60

20 15 10

Ta [°C]
A B

-40 -20

0

20 40 60

CP-B 24/20.0

Ta [°C]

A Normal application (up to 50 % buffer mode, 5 charging and discharging cycles in direct series)
B Continuous charging and discharging in direct series. As this is not typical of a real application, this should be considered as theoretical indication

2CDC 272 030 F0210

2CDC 272 010 F0017

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

337

-- CP-B range Technical diagrams

-- Dimensional drawings Dimensions in mm, inches

IEC/EN 60715 TH 35-7.5 TH 35-15

IEC/EN 60715 TH 35-7.5 TH 35-15

92.5 3.64" 99.8 3.93"

92.5 3.64" 99.8 3.93"

2CDC 272 007 F0017

112.4 4.43" 121.2 4.77" 126.2 4.97"
CP-B 24/3.0

60.0 2.36"

112.4 4.43" 121.2 4.77" 126.2 4.97"
CP-B EXT.2

60.0 2.36"

IEC/EN 60715 TH 35-7.5 TH 35-15

163.0 6.42" 167.9 6.61"

2CDC 272 008 F0017

CP-B 24/10.0

137.8 5.43" 145.3 5.72" 151.0 5.95"

115.6 4.55"

IEC/EN 60715 TH 35-7.5 TH 35-15

192.5 7.58" 198.0 7.80"

2CDC 272 009 F0017

CP-B 24/20.0

187.8 7.4" 195.3 7.7" 215.8 8.5"

83.7 3.3"

338

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

339

-- Redundancy units Table of contents

341

Benefits and advantages

342

Ordering details

343

Technical data

347

Technical diagrams

340

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- --Establish true redundancy Rwehdeurenditarnecaylluynmitastters with BAeBnBe'sfiptsoawnedr asduvpapnltyages redundancy units.

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

341

-- Redundancy units Benefits and advantages

ABB's redundancy units are used to establish true redundancy, which increases the availability of electrical systems significantly. Three versions are available with different output currents and power supply housings:
· CP-D RU in MDRC housing · CP-RUD for a true redundant setup of two 24 V DC power supplies with a
max. output current of 2.5 A per channel · CP-C.1-A-RU for a true redundant setup of two 24 V DC power supplies
of the CP range

24 7
Continuous operation

Highest system reliability · Redundancy setup of the application possible to allow parallel operation · Long lifetime

342

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Redundancy units Ordering details

CP-C.1-A-RU CP-C.1-A-RU-L CP-D RU

2CDC 271 010 F0006

2CDC271001V0019

2CDC271001V0018

Description Whenever the highest availability and reliability are key requirements, a true redundancy setup with two power supplies connected to a redundancy unit is the best solution. In case one power supply fails, the other one keeps supplying the load. Furthermore, even a short circuit in one power supply will not affect the other one, which keeps supplying the load. The CP-C.1-A-RU is also available with coated PCBA (CP-C.1-A-RU-C) for harsh environments.

-- Ordering details - CP-C.1-A-RU for decoupling of CP power supplies up to 20 A per input / channel

Input voltage range

Rated input current per channel

Rated output voltage / current

Type

Order code

10 - 28.5 V DC 20 A

24 V DC / 2 x 20 A or 1 x 40 A

uncoated CP-C.1-A-RU

1SVR360060R1001

coated CP-C.1-A-RU-C 1SVR360060R2001

uncoated CP-C.1-A-RU-L 1SVR361060R1001

Weight (1 pc.)
kg (lb) 1.04 (2.29)
1.04 (2.29) 1.04 (2.29)

-- Ordering details - CP-D RU for decoupling of two CPD power supply units

Input voltage Rated input Rated output voltage / Type

range

current

current

Order code

9-35 V DC

2 x 5 A

24 V DC / 1 x 10 A

CP-D RU

1SVR427049R0000

Weight (1 pc.) kg (lb)
0.075 (0.165)

-- Ordering details - CP-RUD for decoupling of two CPE power supply units  35 V and < 5 A

Input voltage Rated input Rated output voltage / Type

range

current

current

5-35 V DC

0.5 - 2.5 A 24 V DC / 5 A

CP-RUD

Order code 1SVR423418R9000

Weight (1 pc.) kg (lb)
0.088 (0.195)

2CDC 271 006 F0003

CP-RUD

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

343

-- Redundancy units Technical data

Data at Ta = 25 °C, Uin = 230 V AC and rated values, unless otherwise indicated

Type

CP-C.1-A-RU, CP-C.1-A-RU-L

CP-C.1-A-RU-C

Input circuit - Supply circuit

(+/+, -/-)

Rated input voltage Uin Input voltage range

24 V DC 10-28.5 V DC

Rated input current Iin per channel Maximum input current per channel
Transient overvoltage protection

-25 °C m Ta m 60 °C -25 °C m Ta m 40 °C -40 °C m Ta m 40 °C

20 A 30 A yes, varistor

30 A

Output circuit

(++/--)

Rated output voltage Uout Voltage drop input/output

24 V DC typ. 0.6 V, max. 0.9 V

Rated output current Ir Max. output current (Power reserve)
Derating of the output current Resistance to reverse feed

-25 °C m Ta m 60 °C 2 x 20 A or 1 x 40 A

-25 °C m Ta m 40 °C 2 x 30 A or 1 x 60 A

-40 °C m Ta m 40 °C -

2 x 30 A or 1 x 60 A

60 °C < Ta m 70 °C 2.5 % per Kelvin temperature increase

< 60 V

General data

Power loss

input 2 x 20 A 23.0 W

input 2 x 10 A 9.4 W

input 2 x 5 A 4.1 W

MTBF

acc. to MIL 217 HDBK on request

Dimensions

see "Dimensional drawings"

Material of housing

cover / housing shell / front aluminium / zinc-coated sheet steel / plastic

Mounting

DIN rail (IEC/EN 60715), snap-on mounting

Mounting position

1 and 7

Minimum distance to other units

horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in)

Degree of protection (IEC/EN 60529)

housing / terminals IP20 / IP20

Protection class (IEC/EN 61140)

III

Electrical connection - Input circuit / Output circuit

Connecting capacity

fine-strand with(out) wire end ferrule 2.5-10 mm2 (12-8 AWG)

rigid 2.5-16 mm2 (12-6 AWG)

Stripping length

10 mm (0.39 in)

Tightening torque

1.2 Nm (10.5 lb.in)

Recommended screw driver

PH1 / Ø 4.0 x 0.8 mm (0.16 x 0.03 in)

344

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Redundancy units Technical data

Type Environmental data Ambient temperature range
Climatic class (IEC/EN 60721-3-1) Climatic class (IEC/EN 60721-3-2) Climatic class (IEC/EN 60721-3-3)

CP-C.1-A-RU, CP-C.1-A-RU-L

CP-C.1-A-RU-C

operation -25...+70 °C (-13... +158 °F) rated load -25...+60 °C (-13... +140 °F)
storage -40...+85 °C (-40...+185 °F) transportation -40...+85 °C (-40...+185 °F)
storage 1K2 (-40...+85 °C / -40...+185 °F) transportation 2K2 (-40...+85 °C / -40...+185 °F)
operation 3K3 (-25...+70 °C / -13...+158 °F)

-40...+70 °C (-40...+158 °F) -40...+60 °C (-40...+140 °F)
3K3 (-40...+70 °C / -40...+158 °F)

Damp heat, cyclic (IEC/EN 60068230) Vibration (IEC/EN 6006826)

test Db: 55 °C, 2 cycles
test Fc: 10-58 Hz, amplitude ±0.15 mm, 58-150 Hz, 2 g, 10 sweep cycles each axis

Shock, halfsine (IEC/EN 60068227)

test Ea: 30 g, 6 ms, 3 pulses each axis; bump 20 g, 11 ms, 100 pulses each axis

Coated PCBA

no

yes

Gaseous corrosive environment withstand test (IEC/EN 60068-2-60)

-

testing method: 4 testing period: 21 days ambient conditions: 25 °C, 75 % r.h. air/volume change rate per hour: 3-6 sample not energized during exposure gas concentrations acc. ISA-S71.04.2013 Harsh Group A, G3 IEC 60721-3.3 acc. 3C2/3C3 - H2S  100 ± 10 ppb - SO2/SO3  300 ± 20 ppb - Cl2  100 ± 10 ppb - NOx  1250 ± 20 ppb

Isolation data

Rated impulse withstand voltage Uimp (EN 50178)

input / housing 1.5 kV (1.2/50 µs) output / housing 1.5 kV (1.2/50 µs)

Pollution degree

2

Standards / Directives

Standards

IEC/EN 61204

EMC Directive

2014/30/EU

ATEX Directive

-

2014/34/EU

RoHS Directive

2011/65/EU

Electrical safety

IEC/EN 60950-1

Industrial control equipment / General Use Power Supplies

UL 508 / CSA 22.2 No 107.1

Electromagnetic compatibility

Interference immunity to

electrostatic discharge

IEC/EN 61000-4-2 Level 4, contact discharge ±8 kV, air discharge ±15 kV (criterion B)

electrical fast transient / burst

IEC/EN 61000-4-4 Level 3, DC mains inputs and output ±2 kV (criterion B)

surge

IEC/EN 61000-4-5 Level 1, DC mains inputs and output ±0.5 kV, input and output vs. PE ±1 kV (criterion B)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

345

-- Redundancy units Technical data

Type

CP-D RU

Input circuit - Supply circuit

IN 1 + + -, IN 2 + + -

Rated input voltage Uin Input voltage range

24 V DC 9-35 V DC

Rated input current Iin per channel Maximum input current per channel

5 A 10 A for 300 s

Transient overvoltage protection

no

Output circuit

OUT + + +, - - -

Rated output voltage Uout Voltage drop

24 V DC typ. 0.5 V

Rated output current Iout Resistance to reverse feed

10 A < 35 V

General data

MTBF

on request

Duty cycle

100 %

Dimensions

see "Dimensional drawings"

Material of housing

plastic

Mounting

DIN rail, snap-on mounting without any tool

Mounting position

1, 7

Minimum distance to other units

horizontal / vertical 25 mm (0.98 in) / 25 mm (0.98 in)

Electrical connection - Input circuit / Output circuit

Connecting capacity

fine-strand with (out)wire end ferrule 0.2-2.5 mm2 (24-14 AWG)

rigid 0.2-2.5 mm2 (24-12 AWG)

Stripping length

7.0 mm (0.28 in)

Tightening torque

0.67 Nm (6 Ib.in)

Environmental data

Ambient temperature range

operation -40...+70 °C

storage -40...+85 °C

Relative humidity

RH at 40 °C 20-95 %, no condensation

Vibration (IEC/EN 60068-2-6)

mounting by rail: 10-500 Hz, 2 G, along X, Y, Z each axis, 60 min for each axis

Shock (IEC/EN 60068-2-27) Standards / Directives Standards RoHS Directive Electromagnetic compatibility Interference immunity to electrostatic discharge radiated, radio-frequency, electromagnetic field electrical fast transient/burst conducted disturbances, induced by radio-frequency fields Interference emission high-frequency radiated high-frequency conducted

15 G, 11 ms, 3 axis, 6 faces, 3 times for each face
IEC/EN 61204-3, IEC/EN 60950-1 2011/65/EU
EN 55024 IEC/EN 61000-4-2 level 3, air discharge 8 kV, contact discharge 4 kV IEC/EN 61000-4-3 level 3, 10 V/m IEC/EN 61000-4-4 level 3, 2 kV / 5 kHz IEC/EN 61000-4-6 level 3, 10 V
EN 55022 IEC/CISPR 22 / EN 55022 class B IEC/CISPR 22 / EN 55022 class B

346

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Redundancy units Technical data

Type

CP-RUD

Input circuit - Supply circuit

A: U1+/-U ; B: U2+/-U

Rated input voltage Uin Input voltage range

24 V DC 5-35 V DC

Rated input current Iin per channel Maximum input current per channel

0.5-2.5 A 10 A for 300 s

Transient overvoltage protection

no

Output circuit

L+, L+, L+, L-, L-, L-

Rated output voltage Uout Voltage drop

24 V DC typ. 0.6 V, max. 0.7 V

Rated output current Iout Peak output current

0.5-5 A 20 A for 150 s

Resistance to reverse feed

< 35 V

General data

Dimensions

see "Dimensional drawings"

Minimum distance to other units

horizontal / vertical 10 mm / 10 mm (0.39 in / 0.39 in)

Degree of protection

housing / terminals IP20 / IP20

Material of housing

housing shell / cover plastic / plastic

Protection class

-

Mounting

DIN rail (IEC/EN 60715)

Mounting position

horizontal

Electrical connection - Input circuit / Output circuit

Connecting capacity

fine-strand with wire end ferrule 2 x 0.75-2.5 mm2 (2 x 18-14 AWG)

fine-strand without wire end ferrule

rigid 2 x 0.5-4 mm2 (2 x 20-12 AWG)

Stripping length

7 mm (0.28 in)

Tightening torque

0.6-0.8 Nm

Environmental data

Ambient temperature range

operation -20...+60 °C

rated load -20...+60 °C

storage -40...+85 °C

Damp heat (IEC/EN 60068-2-3)

93 % at 40 °C, no condensation

Isolation data

Insulation voltage

input / output / housing -

Pollution degree (EN 50178)

2

Standards / Directives

Electrical safety

EN 50178

RoHS Directive

2011/65/EU

Electromagnetic compatibility

Interference immunity to

IEC/EN 61000-6-2

electrostatic discharge

IEC/EN 61000-4-2 level 3 (air discharge ±8 kV, contact discharge ±6 kV)

radiated, radio-frequency, electromagnetic field

IEC/EN 61000-4-3 level 3 (10 V/m)

electrical fast transient/burst

IEC/EN 61000-4-4 level 3 (w2 kV)

surge
conducted disturbances, induced by radio-frequency fields

IEC/EN 61000-4-5 level 1 (w0.5 kV) IEC/EN 61000-4-6 level 3 (10 V)

Interference emission high-frequency radiated high-frequency conducted

IEC/EN 61000-6-3 class B class B

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

347

-- Redundancy units Technical diagrams

-- Dimensional drawings Dimensions in mm, inches

129.8 5.11" 126.8 4.99"

56.4 2.22"

INPUT 1

+

-

INPUT 2

+

-

IEC/EN 60715 TH 35-7.5 TH 35-15

CP-C.1-A-RU

136.0 5.35" CP-C.1-A-RU, CP-C.1-A-RU-L CP-C.1-A-RU-C
109.5 4.31" 102 4.02"

+

+

-

-

OUTPUT

22.5 .886"

129.4 5.09"
2CDC272011F0017 91.0 3.58"

35.0 1.38"

+ + + + - - IN1

IN2

IN1 IN2

+++ - - O U T
CP-D RU

67.0 2.64" 44.5 1.75"

32.1 1.26" 49.0 1.93" 57.5 2.26"
2CDC272033F0010

78 3.07"
2CDC252188F0B05

CP-RUD

100 3.94"

348

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

349

-- Electronic protection devices EPD24 Table of contents

350

Benefits and advantages

351

Applications

352

Ordering details

353

Operating data

354

Technical data

355

Technical information

356

Technical diagrams

357

Approvals, Safety instructions

358

Installation guidelines

350

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Electronic protection devices EPD24 Benefits and advantages

With its narrow width of only 12.5 mm, EPD24 can fit everywhere ­ it can even be mounted side-by-side.
Its adjustable and fixed current ratings, projectable protection through current limitation as well as a single trip curve for all types of loads allow for use in a wide field of applications.

24 7
Continuous operation

Highlights · Safety and reliability · Operational continuity · Worldwide use thanks to relevant certifications · Compact and effective

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

351

-- Electronic protection devices EPD24 Applications

Features · Selective load protection, one electronic tripping
characteristic. · Active current limitation for safe connection of capacitive
loads up to 20,000 µF and on overload/short circuit · Current ratings 0.5...12 A · Reliable overload disconnection with 1.1 x IN · Manual ON/OFF button · Clear status and failure indication through LED and
integrated auxiliary contact · Integral fail-safe element adjusted to current rating · Width per unit only 12.5 mm · Rail mounting · Ease of wiring through busbar LINE+ and 0 V as well
as signal bars · UL- and CSA-approvals allow international use
of the devices

Applications · Packaging machines · Automation · Automation & Process Control · Automotive Manufacturing · Chemical, Oil & Gas · Medical Equipment · Pharmaceutical & Food · Power Engineering DC 24 V · Renewable Energy · Steel Production

352

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Electronic protection devices EPD24 Ordering details

EPD24-TB-101-3A

2CDC 051 001 S0010

Description The protection devices EPD24 extend the ABB product range of modular DIN rail components by electronic overcurrent protection modules for selective protection of 24 V DC load circuits. This protection is achieved by a combination of active electronic current limitation in the case of a short circuit and an overload deactivation from 1.1 x In upwards. If a fault occurs in a load circuit, the protection device EPD24 will detect this rapidly and reliably, then disable the power output transistor and hence interrupt the current flow in the defective circuit. The maximum possible overcurrent is always limited to 1.3...1.8 times the selected rated current. An activation of capacitive loads up to 20,000 F is possible, deactivation only occurring in the case of overloads or short circuits. Selective deactivation of the defective current circuit means undefined error states and a complete system stop are prevented.
-- Ordering details

Rated current IN bbn 40 16779 EAN

A

0.5

829960

1

829984

2

830003

3

830027

4

830041

6

830065

8

830089

10

830102

12

830126

Type

Order code

EPD24-TB-101-0.5A 2CDE601101R2905 EPD24-TB-101-1A 2CDE601101R2001 EPD24-TB-101-2A 2CDE601101R2002 EPD24-TB-101-3A 2CDE601101R2003 EPD24-TB-101-4A 2CDE601101R2004 EPD24-TB-101-6A 2CDE601101R2006 EPD24-TB-101-8A 2CDE601101R2008 EPD24-TB-101-10A 2CDE601101R2010 EPD24-TB-101-12A 2CDE601101R2012

Pkg Weight qty (1 pc.)
kg (lb)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

4

0.065

(1.433)

Description

bbn 40

Type

16779 EAN

Busbars for LINE+ and 0 V, grey 830140 insulation, length 500 mm 1)
Signal bars for aux. contacts, 830164 grey insulation, length 21 mm

EPD-BB500 EPD-SB21

1) Max. load with one line entry Imax = 50 A (recommended: mid line entry) Max. load with two line entries Imax = 63 A

Order code 2CDE605100R0500 2CDE605200R0021

Pkg Weight qty (1 pc.)
kg (lb)
10 0.2 (0.441)
10 0.4 (0.882)

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

353

-- Electronic protection devices EPD24 Operating data

Operating data Operating voltage UB Current rating IN Closed current I0 Status indication by means of
Load circuit Load output Overload disconnection Short-circuit current IK Trip time For electronic disconnection
Temperature disconnection Low voltage monitoring load output Starting delay tStart Disconnection of load circuit Free-wheeling circuit Several load outputs must not be connected in parallel Signal output Electrical data
ON condition LED green
OFF condition LED off
Fault condition LED orange Fault condition LED red
Aux. contact
Fault

24 V DC (18...32 V) fixed current ratings: 0.5, 1, 2, 3, 4, 6, 8, 10, 12 A ON condition: typically 20...30 mA depending on signal output Green: unit is ON load circuit / Power-MOSFET is switched on Orange: in the event of overload or short circuit until electronic disconnection Red: unit electronically disconnected load circuit/Power-MOSFET OFF undervoltage (UB < 8 V) after switch-on till the end of the delay period OFF: manually switched off or device is dead potential-free auxiliary contact F ON/OFF/ condition of switch
Power-MOSFET switching output (high slide switch) typically 1.1 x IN (1.05...1.35 x IN) active current limitation see time/current characteristics typically 3 s at ILoad > 1.1 x IN typically 100 ms...3 s at ILoad > 1.8 x IN (or 1.5 x IN/1.3 x IN, ) internal temperature monitoring with electronic disconnection with hysteresis, no reset required: load »OFF« at UB< 8 V typically 0.5 sec after every switch-on and after applying UB electronic disconnection suitable external free-wheeling circuit to be used with inductive load
potential-free auxiliary contact max. 30 V DC/0.5 A, min. 10 V DC/10 mA
voltage UB applied, switch is in ON position no overload, no short circuit
device switched off (switch is in OFF position) no voltage UB applied overload condition > 1.1 x IN up to electronic disconnection electronic disconnection upon overload or short circuit Device switched off with control signal (switch is in ON position)
single signal, make contact contact open, terminal 13-14
signal output fault conditions no operating voltage UB ON/OFF switch is in OFF position red LED lighted (electronic disconnection)

354

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Electronic protection devices EPD24 Technical data

General data Fail-Safe element
Housing material Mounting Ambient temperature Storage temperature Humidity
Vibration Degree of protection
EMC (EMC directive, CE logo) Isolations coordination (IEC 60934) Dielectric strength Isolation resistance (OFF condition) Approvals/Declarations of conformity
Dimensions (B x H x T) Weight Terminals Screw terminals Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve Multi-lead connection (2 identical cables) rigid/flexible Flexible with wire end ferrule without plastic sleeve Flexible with TWIN wire end ferrule with plastic sleeve Wire stripping length Tightening torque (EN 60934) Terminals Screw terminals Max. cable cross section flexible with wire end ferrule w/wo plastic sleeve Wire stripping length Tightening torque (EN 60934)

backup fuse for EPD24 not required because of the integral redundant fail-safe element
moulded symmetrical rail to EN 50022-35x7.5 0...+50 °C (without condensation, see EN 60204-1) -20...+70 °C 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721
3 g, test to IEC 60068-2-6 test Fc housing: IP20 DIN 40050 terminals: IP20 DIN 40050
emission: EN 61000-6-3 susceptibility: EN 61000-6-2
0.5 kV/pollution degree 2 reinforced insulation in operating area
max. 32 V DC (load circuit) n/a, only electronic disconnection UL 2367 Solid State Overcurrent Protectors UL 1604, (class I, division 2, groups A, B, C, D) UL 508 CSA C22.2 No. 213 (class I, division 2) CSA C22.2 No. 142 CE logo 12.5 x 80 x 83 mm approx. 65 g Line+/LOAD+/0V M4 0.5 ­ 10 mm2 0.5 ­ 4 mm2 0.5 ­ 2.5 mm2 0.5 ­ 6 mm2 10 mm 1.5 ­ 1.8 Nm aux. contacts M3 0.25 - 2.5 mm2
8 mm 0.5 Nm

Table 1: voltage drop, current limitation, max. load current

current rating

typically voltage drop

active current

IN

UON at IN

limitation (typically)

0.5 A 1 A 2 A 3 A 4 A 6 A 8 A 10 A 12 A

70 mV 80 mV 130 mV 80 mV 100 mV 130 mV 120 mV 150 mV 180 mV

1.8 x IN 1.8 x IN 1.8 x IN 1.8 x IN 1.8 x IN 1.8 x IN 1.5 x IN 1.5 x IN 1.3 x IN

max. load current at 100 % ON duty

Tambient = 40 °C

Tambient = 40 °C

0.5 A

0.5 A

1 A

1 A

2 A

2 A

3 A

3 A

4 A

4 A

6 A

5 A

8 A

7 A

10 A

9 A

12 A

10.8 A

Attention: when mounted side-by-side without convection, the ERD24 should carry no more than 80 % of its rated load with 100 % ON duty due to thermal effects.

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

355

-- Electronic protection devices EPD24 Technical information

Time/Current characteristic curve (Tambient = 25 °C)

The

trip

time

is

typically

3

s

in

the

range

between

1.1

and

1.8

x

I 1) N.

Electronic current limitation occurs at typically 1.8 x IN1) which means that under all overload conditions (independent of the

power supply and the resistance of the load circuit) the max. overload before disconnection will not exceed 1.8 x IN1) times

the current rating. Trip time is between 100 ms and 3 sec (depending on overload or at short circuit).

Without this current limitation a considerably higher overload current would flow in the event of an overload or short circuit.

Maximum cable lenghts EPD24 reliably trips from 0  up to max. circuit resistance Rmax.

Calculation of Rmax
Selected rating IN (A) Operating voltage US (V DC) (= 80 % of 24 V) 2) Trip current Iab = 1.25 x IN (A) (EPD24 trips after 3 s) Rmax () = (UB/Iab) -0.050

3 19.2 3.75 5.07

2) Voltage drop of EPD24 and tolerance of trip point (typically 1.1 x IN = 1.05 ... 1.35 x IN) have been taken into account

6 19.2 7.50 2.51

Selection table for the incoming cable lengths with different cable cross-sections

Cable cross section A (mm2) Cable length L (m) (= single length) 5 10

0.14

0.25

0.34

cable resistance () = (0 x 2 x L) / A 3)

1.27

0.71

0.52

2.54

1.42

1.05

0.5
0.36 0.71

15

3.81

2.14

1.57

1.07

20

5.09

2.85

2.09

1.42

25

6.36

3.56

2.62

1.78

30

7.63

4.27

3.14

2.14

35

8.90

4.98

3.66

2.49

40

10.17

5.70

4.19

2.85

45

11.44

6.41

4.71

3.20

50

12.71

7.12

5.24

3.56

75

19.07

10.68

7.85

5.34

100

25.34

14.24

10.47

7.12

125

31.79

17.80

13.09

8.90

150

38.14

21.36

15.71

10.68

175

44.50

24.92

18.32

12.46

200

50.86

28.48

20.94

14.24

225

57.21

32.04

23.56

16.02

250

63.57

35.60

26.18

17.80

0.75
0.24 0.47 0.71 0.95 1.19 1.42 1.66 1.90 2.14 2.37 3.56 4.75 5.93 7.12 8.31 9.49 10.68 11.87

3) Resistivity of copper 0 = 0.0178 ( x mm2)/m Example 1: max. length for 1.5 mm2 and 3 A: 214 m
Example 2: max. length for 1.5 mm2 and 6 A: 106 m

Example 3: mixed wiring: (Control cabinet --- sensor/actuator level) R1 = 40 m for 1.5 mm2 and R2 = 5 m for 0.25 mm2: R1 = 0.95 , R2 = 0.71 , total (R1 + R2) = 1.66 

1.00
0.18 0.36 0.53 0.71 0.89 1.07 1.25 1.42 1.60 1.78 2.67 3.56 4.45 5.34 6.23 7.12 8.01 8.90

1.50
0.12 0.24 0.36 0.47 0.59 0.71 0.83 0.95 1.07 1.19 1.78 2.37 2.97 3.56 4.15 4.75 5.34 5.93

356

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Electronic protection devices EPD24 Technical diagrams

El--Teimke/tCruorrennticshacrahcteerirsticScuircveherungsautomat ESX10-T Installations- und Sicherheitshinweise
disconnection typically 1.1 x IN 1.8 x IN1) 10000
1000 ESX10-T Signaleingänge/-ausgänge (Anschlussdiagramme)

trip time in seconds

100 current limitation 1) typically 1.8 x IN
10 5
1
X10-T Signaleingänge / -ausgänge (Anschlussdiagramme) e Signalkontakt0e.1 werden im Aus- oder Fehlerzustand gezeigt

0.01

0

1

X10-TA-100 ne Signaleingang/-Ausgang
--
Wiring diagram

2

3

4

5 IK

...times rated current

ESX10-TB-101 Ohne Signaleingang Mit Meldeausgang F (Einzelsignal, Schließer)

1) Current limitation typically 1.8 x IN at IN = 0.5 A...6 A Current limitation typically 1.5 x IN at IN = 8 A or 10 A Current limitation typically 1.3 x IN at IN = 12 A
ESX10-TB-102 Ohne Signaleingang Mit Meldeausgang F (Einzelsignal, Öffner)

LINEPED+24-TB1-101
without signal input with signal output F (Single signal, N/O)
Operating condition: 13-14 closed Fault condition: 13-14 open

LINE+ 1 14

LINE+ 1 12

13

11

2

LOAD+

2 LOAD+

2 LOAD+

0V 3

0V

3

Normalzustand: 13-14 geschlossen Fehlerzustand: 13-14 geöffnet

0V 3
Normalzustand: 11-12 geöffnet Fehlerzustand: 11-12 geschlossen

X10-TB-114 Steuereingang IN+ DC 24 V) Statusausgang SF 4 V = Lastausgang EIN)
LINE+ 1

ESX10-TB-124
Mit Reseteingang RE (+DC 24 V ) Mit Statusausgang SF
(+24 V = Lastausgang EIN)

LINE+

1

ESX10-TB-127
Mit Reseteingang RE (+DC 24 V ) Mit Statusausgang SF invertiert
(0 V = Lastausgang EIN)

LINE+

1

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

357

-- Electronic protection devices EPD24 Approvals, Safety instructions

Please note The user must ensure that the cable cross sections of the relevant load circuit are suitable for the current rating of the EPD24 used. Automatic start-up of machinery after shut down must be prevented (Machinery Directive 2006/42/EU and IEC/EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically by the EPD24.
Information on UL approvals/CSA approvals UL1604 UL File # E 339238
CSA C22.2 No. 213 (Class I, Division 2) CSA File # 2305929
Operating Temperature Code T5 · This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only WARNING: · Exposure to some chemicals may degrade the sealing properties of materials used in the following device: relay
Sealant Material: - Generic Name: Modified diglycidyl ether of bisphenol A - Supplier: Fine Polymers Corporation - Type: Epi Fine 4616L-160PK · Casing Material: - Generic Name: Liquid Crystal Polymer - Supplier: Sumitomo Chemical - Type: E4008, E4009, or E6008
RECOMMENDATION: · Periodically inspect the device named above for any degradation of properties and replace if degradation is found
WARNING ­ EXPLOSION HAZARD: · Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous · Substitution of any components may impair suitability for Class I, Division 2
UL2367 Non-hazardous use - UL File # E 339236
UL 508 Non-hazardous use - UL File # E 149922
CSA C22.2 No. 14 CSA C22.2 No. 142 - CSA File # E 2305929
Class 2 Meets requirement for Class 2 current limitation (EPD24 ... -0,5 A/1 A/2 A/3 A)

358

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

-- Electronic protection devices EPD24 Installation guidelines

The EPD24 features an integral power distribution system. The following wiring modes are possible with various pluggable current and signal busbars: · LINE+ (24 V DC) · 0V
Caution: The electronic devices EPD24 require a 0 V connection · Auxiliary contacts

LINE+ busbar 2CDE605100R0500

continuous busbar 500 mm length, cut

(12.5 x n)-3 = length of busbars ± 0.5 e. g. (12.5 x 5)-3 = 59.5 ± 0.5

signal bar 2CDE605200R0021

remove protection against brush contact from bottom side

0 V busbar 2CDE605100R0500

insert busbars and protection slides to be flush with housing sides

insert signal bars to be flush with housing and place them centrally over the contacts

insert protection against brush contact
12.5 x n = width of protector block e. g. 12.5 x 5 = 62.5

Mounting procedure Before wiring insert busbars into protector block. A maximum of 10 connection cycles are permissible using connecting busbars.

Recommendation After 10 units the busbars should be interrupted and receive a new entry live.

Table of length for busbars

(Order code 2CDE605100R0500)

No. of units

2

Length of busbar (mm) ± 0.5 mm

22

3

4

34.5

47

5

6

59.5

72

7

8

84.5

97

9

10

109.5

122

ELECTRONIC RELAYS AND CONTROLS CATALOG PRIMARY SWITCH MODE POWER SUPPLIES

359

360

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

361

-- Interface relays and optocouplers Table of contents

362

Offer overview

365

Applications

367

Pluggable interface relays

and optocouplers

368

Selection tables

370

List of components

385

Benefits and advantages

386

Socket & terminal connection types

387

Relay components

389

Ordering details

410

Technical data

424

Technical diagrams

437

Boxed interface relays and

optocouplers R600 range

438

Overview

440

Boxed interface relays R600 range

440

Selection table

442

Ordering details

444

Technical data

448

Technical diagrams

450

Boxed optocouplers R600 range

450

Selection table

451

Ordering details

453

Technical data

456

Technical diagrams

362

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Interface relays and optocouplers Offer overview

Relays are universally applicable and are utilized in a diverse array of applications. They are a significant element in contemporary industrial processes and are used in applications where galvanic isolation, signal separation, voltage coupling and signal amplification are required.

The ABB portfolio includes electromechanical relays and optocouplers. The electromechanical relays operate using an electromagnetic field whereas optocouplers use light. Optocouplers are predominantly used in applications where a high switching frequency is necessary. Furthermore, optocouplers do not contain any moving parts and are therefore bouncefree, immune to vibrations and possess a long electrical life.
CR-S range The slim line of interface relays and optocouplers The pluggable interface relays and optocouplers of the CR-S range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-S range combines the flexibility of a modular system and the ability of switching high currents on a small footprint thus can be used in applications where space saving is essential. The CR-S range also includes complete versions consisting of a relay, socket and marker.

CR-P range The pluggable pcb interface relays and optocouplers The pluggable interface relays of the CR-P range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-P range offers highest current switching in an IP67 rated relay housing. Furthermore, nine different coil voltages are available to suit world wide applications and even gold contact versions are available which is essential when it comes to switch sensitive signals. The CR-P range also includes complete versions consisting of a relay, socket, holder, marker and function module.

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

363

-- Interface relays and optocouplers Offer overview

CR-M range The pluggable miniature interface relays The pluggable interface relays of the CR-M range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-M range offers up to 4 contacts in one relay and a built in test button which makes a circuit check fast and easy. 12 different coil voltages are available to suit world wide applications and even gold contact versions are available which is essential when it comes to switch sensitive signals. The CR-M range also includes complete versions consisting of a relay, socket, holder, marker and where applicable a function module.

CR-U range The pluggable universal interface relays The pluggable interface relays of the CR-U range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The CR-U range offers up to 3 contacts in one relay and a built in test button which makes a circuit check fast and easy. 12 different coil voltages are available to suit world wide applications.

R600 range Boxed interface relays and optocouplers Boxed interface relays of the R600 range are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC, iPC or field bus systems and the sensor / actuator level. The relay itself is built in thus the perfect solution because this design fulfills highest vibration requirements. The compact design and different connection terminal possibilities further optimize your panel installation.

364

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

365

-- Applications of interface relays A proven technology used worldwide

Relays are universally applicable and are utilized in a diverse array of applications. They are a significant element in contemporary industrial processes and are used in applications where galvanic isolation, signal separation, voltage coupling and signal amplification are required.

Circuit multiplication
A single voltage signal may be used to simultaneously perform up to four different switching operations. Each output contact can be used to switch load circuits with different voltage and current levels.

Galvanic isolation
Interface relays are excellently suited to ensure safe galvanic isolation, i.e. separation between control circuit and load circuit.

Voltage conversion Interface relays allow for small voltage signals to switch much larger loads. For example: a 24 V DC 10 mA signal can be used to switch a 230 V AC 16 A load.

Billions
of relays operate and interface between control circuits and electrical
loads.

Sensor

110 V AC 230 V AC

Motor

380 V AC

Interface relay Input
24 V DC

Controller (PLC)

Contactor
110 V AC 230 V AC

24 V DC Outout Interface relay

366

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

367

-- Pluggable interface relays and optocouplers Table of contents

368

Selection tables

370

List of components

385

Benefits and advantages

386

Socket & terminal connection types

387

Relay components

389

Ordering details

389

CR-S range

393

CR-P range

397

CR-M range

404

CR-P/M function modules

406

CR-U range

408

CR-U function modules

410

Technical data

410

CR-S interface relays

411

CR-S optocouplers

412

CR-S sockets

413

CR-S jumper bars

414

CR-P, CR-M, CR-U

418

CR-P optocouplers

419

CR-P and CR-M sockets

420

CR-P and CR-M jumper bars

421

CR-P and CR-M function modules

422

CR-U sockets

423

CR-U function modules

424

Technical diagrams

368

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays Selection table CR-S range

How to use the selection table Choose the desired control supply voltage from the column "Control voltage", e.g. "5 V DC". Choose the desired kind of connection terminal from the column "Connection terminal", e.g. "spring". Choose the desired material of contact from the column "Contact Material" e.g. "gold plated".

Control voltage 5 V DC
12 V AC

Connection terminal screw
spring
screw
spring

Contact material standard gold plated standard gold plated standard gold plated standard gold plated

Socket type
CR-S006/024VDC1SS CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ

Socket order code
1SVR405521R1100 1SVR405521R1100 1SVR405521R1200 1SVR405521R1200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200

Relay type

Relay order code

CR-S005VDC1R CR-S005VDC1RG CR-S005VDC1R CR-S005VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG

1SVR405501R1010 1SVR405501R1020 1SVR405501R1010 1SVR405501R1020 1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020

Example When you have chosen 5 V DC as control supply voltage, spring connection as connection terminal and gold plated as contact material the following order codes and type designators are valid:
Socket: CR-S006/024VDC1SZ, 1SVR405521R1200 Relay: CR-S005VDC1RG, 1SVR405501R1020

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

369

-- CR-S range relay assemblies

Control voltage 5 V DC

Connection terminal
screw

spring

12 V DC

screw

spring

12 V AC 24 V DC

screw spring screw

spring

24 V AC

screw

spring

48 V AC/DC

screw

spring

60 V AC/DC

screw

spring

110-125 V AC/DC screw

spring

220-240 V AC/DC screw

spring

Contact material standard gold plated standard gold plated standard
gold plated
standard
gold plated
standard gold plated standard gold plated standard
gold plated
standard
gold plated
standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated

Socket type
CR-S006/024VDC1SS CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S006/024VDC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S220/240VADC1SZ

Socket order code
1SVR405521R1100 1SVR405521R1100 1SVR405521R1200 1SVR405521R1200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R6100 1SVR405521R6100 1SVR405521R6200 1SVR405521R6200 1SVR405521R7100 1SVR405521R7100 1SVR405521R7200 1SVR405521R7200

Relay type

Relay order code

CR-S005VDC1R CR-S005VDC1RG CR-S005VDC1R CR-S005VDC1RG CR-S012VDC1R

1SVR405501R1010 1SVR405501R1020 1SVR405501R1010 1SVR405501R1020 1SVR405501R2010

CR-S012VDC1RG 1SVR405501R2020

CR-S012VDC1R

1SVR405501R2010

CR-S012VDC1RG 1SVR405501R2020

CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S024VDC1R

1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 1SVR405501R3010

CR-S024VDC1RG 1SVR405501R3020

CR-S024VDC1R

1SVR405501R3010

CR-S024VDC1RG 1SVR405501R3020

CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG

1SVR405501R3010 1SVR405501R3020 1SVR405501R3010 1SVR405501R3020 1SVR405501R4010 1SVR405501R4020 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020

-- CR-S optocoupler range relay assemblies

Control voltage
24 V DC

Connection terminal screw spring screw spring screw spring

Output characteristics Transistor 100 mA - 48 V DC
MOS-FET 2 A - 24 V DC
Triac 2 A - 240 V AC

Socket type
CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ

Socket order code
1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200

Opto type
CR-S024VDC1TRA CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1MOS CR-S024VDC1TRI CR-S024VDC1TRI

Opto order code
1SVR405510R3050 1SVR405510R3050 1SVR405510R3060 1SVR405510R3060 1SVR405510R3070 1SVR405510R3070

370

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- List of components Selection table CR-S range complete versions

The complete versions of the CR-S range comprise of a pluggable interface relay, socket and marker.

-- CR-S complete versions

Relay

Socket

CR-S220/240VADC1SZ 1SVR405521R7200

CR-S220/240VADC1SS 1SVR405521R7100

CR-S110/125VADC1SZ 1SVR405521R6200

CR-S110/125VADC1SS 1SVR405521R6100

CR-S012/024VADC1SZ 1SVR405521R3200

CR-S012/024VADC1SS 1SVR405521R3100

1SVR405501R5020

1SVR405501R5010

1SVR405501R3020

Order code 1SVR405501R3010

CR-S060VDC1RG

CR-S060VDC1R

CR-S024VDC1RG

Type CR-S024VDC1R

Complete versions Order code 1SVR405541R3110 1SVR405541R3120 1SVR405541R3210 1SVR405541R3220 1SVR405541R6110 1SVR405541R6120 1SVR405541R6210 1SVR405541R6220 1SVR405541R7110 1SVR405541R7120 1SVR405541R7210 1SVR405541R7220

Type CR-S024VADC1CRS CR-S024VADC1CRGS CR-S024VADC1CRZ CR-S024VADC1CRGZ CR-S110VADC1CRS CR-S110VADC1CRGS CR-S110VADC1CRZ CR-S110VADC1CRGZ CR-S230VADC1CRS CR-S230VADC1CRGS CR-S230VADC1CRZ CR-S230VADC1CRGZ

J

J

JJ

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

11111111122222222222222
JJJJ

JJJJJJJJJ JJJJJJJJJJJJJJ

J

J

J

J

J

J

J

J

Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 16 A 250 V 8 A Output contacts c/o Gold plated contacts

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

Type CR-P012DC1 CR-P024DC1 CR-P048DC1 CR-P110DC1 CR-P024AC1 CR-P048AC1 CR-P110AC1 CR-P120AC1 CR-P230AC1 CR-P012DC2 CR-P024DC2 CR-P048DC2 CR-P110DC2 CR-P012AC2 CR-P024AC2 CR-P048AC2 CR-P110AC2 CR-P120AC2 CR-P230AC2 CR-P024DC2G CR-P024AC2G CR-P110AC2G CR-P230AC2G

Order code 1SVR405600R4000 1SVR405600R1000 1SVR405600R6000 1SVR405600R8000 1SVR405600R0000 1SVR405600R5000 1SVR405600R7000 1SVR405600R2000 1SVR405600R3000 1SVR405601R4000 1SVR405601R1000 1SVR405601R6000 1SVR405601R8000 1SVR405601R0200 1SVR405601R0000 1SVR405601R5000 1SVR405601R7000 1SVR405601R2000 1SVR405601R3000 1SVR405606R1000 1SVR405606R0000 1SVR405606R7000 1SVR405606R3000

-- CR-P pluggable relays

-- Pluggable interface relays and optocouplers Selection table CR-P range

371

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

JJ

JJJJJJ J

JJJ J

JJJJJJJJ JJJJJJJJJJJJJJJJJJ

JJJJJ

JJ JJJJJJ

JJ

JJJJ

JJ JJJJ JJ

JJJ

JJJ

111111111122222222222222222

JJJJJJJJJJ JJJJJJJJJJJJJJJJJ

Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 16 A 250 V 8 A Output contacts c/o Gold plated contacts Socket type Standard socket Logical socket Additional features LED Free-wheeling diode

J JJJJJJ

J JJJ

J JJJJJJJ
J
J

J JJJ
J
J

Type CR-P012DC1SS42V CR-P024DC1SS42V CR-P024DC1LC42V CR-P024DC1LC62C CR-P110DC1SS42CV CR-P024AC1SS62CV CR-P120AC1SS92CV CR-P230AC1SS92CV CR-P230AC1LS CR-P230AC1LC92CV CR-P012DC2SS42V CR-P024DC2SS42V CR-P024DC2LS42 CR-P024DC2LS42V CR-P024DC2LC42 CR-P024DC2GLC42V CR-P024DC2GLC62C CR-P024DC2GLC62CV CR-P110DC2SS42CV CR-P024AC2SS62CV CR-P120AC2SS92CV CR-P230AC2SS92CV CR-P230AC2LS92CV CR-P230AC2LC92 CR-P230AC2GLC92 CR-P230AC2GLC92C CR-P230AC2GLC92CV

Order code 1SVR405600R4010 1SVR405600R1010 1SVR405600R1011 1SVR405600R1013 1SVR405600R8010 1SVR405600R0010 1SVR405600R2010 1SVR405600R3110 1SVR405600R3011 1SVR405600R3010 1SVR405601R4010 1SVR405601R1010 1SVR405601R1013 1SVR405601R1011 1SVR405601R1012 1SVR405606R1010 1SVR405606R1013 1SVR405606R1011 1SVR405601R8010 1SVR405601R0010 1SVR405601R2010 1SVR405601R3110 1SVR405601R3011 1SVR405601R3012 1SVR405606R3013 1SVR405606R3012 1SVR405606R3010

-- CR-P range complete versions

-- Pluggable interface relays and optocouplers Selection table CR-P range

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

372

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

373

-- List of components Selection table CR-P range complete versions

The complete versions of the CR-P range comprise of a pluggable interface relay, socket, holder, marker and a function module.

-- CR-P complete versions

Relay

Socket Function module

Holder

Order code 1SVR405601R4000 1SVR405601R1000 1SVR405606R1000 1SVR405601R8000 1SVR405601R0000 1SVR405601R2000 1SVR405601R3000 1SVR405606R3000 1SVR405650R1000 1SVR405650R0000 1SVR405650R0200 1SVR405652R0000 1SVR405652R1000 1SVR405652R9100 1SVR405655R0000 1SVR405655R1000 1SVR405654R0100 1SVR405655R0100 1SVR405655R1100 1SVR405659R0000

Type CR-P012DC2 CR-P024DC2 CR-P024DC2G CR-P110DC2 CR-P024AC2 CR-P120AC2 CR-P230AC2 CR-P230AC2G CR-PSS CR-PLS CR-PLC CR-P/M 42 CR-P/M 42V CR-P/M 42CV CR-P/M 62C CR-P/M 62CV CR-P/M 92 CR-P/M 92C CR-P/M 92CV CR-PH

Complete versions Order code 1SVR405601R4010 1SVR405601R1010 1SVR405601R1013 1SVR405601R1011 1SVR405601R1012 1SVR405606R1010 1SVR405606R1013 1SVR405606R1011 1SVR405601R8010 1SVR405601R0010 1SVR405601R2010 1SVR405601R3110 1SVR405601R3011 1SVR405601R3012 1SVR405606R3013 1SVR405606R3012 1SVR405606R3010

Type CR-P012DC2SS42V CR-P024DC2SS42V CR-P024DC2LS42 CR-P024DC2LS42V CR-P024DC2LC42 CR-P024DC2GLC42V CR-P024DC2GLC62C CR-P024DC2GLC62CV CR-P110DC2SS42CV CR-P024AC2SS62CV CR-P120AC2SS92CV CR-P230AC2SS92CV CR-P230AC2LS92CV CR-P230AC2LC92 CR-P230AC2GLC92 CR-P230AC2GLC92C CR-P230AC2GLC92CV

J

J

J

J

J

J

J

J

J

JJ

J

J

JJ

J

J

JJ

J

J

JJ

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

JJ

JJ

JJ

JJ

JJ

JJ

J

J

JJ

J

J

JJ

J

J

JJ

J

J

JJ

2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 333 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4

JJJJJJJJJJJJ JJJJJJJJJJJJJ JJJJJJJJJJJJ

J

J

J

J

J

J

J

J

J

Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

Type CR-M012DC2 CR-M024DC2 CR-M048DC2 CR-M060DC2 CR-M110DC2 CR-M125DC2 CR-M220DC2 CR-M024AC2 CR-M048AC2 CR-M110AC2 CR-M120AC2 CR-M230AC2 CR-M012DC3 CR-M024DC3 CR-M048DC3 CR-M060DC3 CR-M110DC3 CR-M125DC3 CR-M220DC3 CR-M024AC3 CR-M048AC3 CR-M060AC3 CR-M110AC3 CR-M120AC3 CR-M230AC3 CR-M012DC4 CR-M024DC4 CR-M048DC4 CR-M060DC4 CR-M110DC4 CR-M125DC4 CR-M220DC4 CR-M024AC4 CR-M048AC4 CR-M110AC4 CR-M120AC4 CR-M230AC4

Order code 1SVR405611R4000 1SVR405611R1000 1SVR405611R6000 1SVR405611R4200 1SVR405611R8000 1SVR405611R8200 1SVR405611R9000 1SVR405611R0000 1SVR405611R5000 1SVR405611R7000 1SVR405611R2000 1SVR405611R3000 1SVR405612R4000 1SVR405612R1000 1SVR405612R6000 1SVR405612R4200 1SVR405612R8000 1SVR405612R8200 1SVR405612R9000 1SVR405612R0000 1SVR405612R5000 1SVR405612R5200 1SVR405612R7000 1SVR405612R2000 1SVR405612R3000 1SVR405613R4000 1SVR405613R1000 1SVR405613R6000 1SVR405613R4200 1SVR405613R8000 1SVR405613R8200 1SVR405613R9000 1SVR405613R0000 1SVR405613R5000 1SVR405613R7000 1SVR405613R2000 1SVR405613R3000

-- CR-M pluggable relays without LED

-- Pluggable interface relays and optocouplers Selection table CR-M range

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

374

JJJ

JJJ

JJJJJJJJJJJJJJJJJJJ

JJJJJJJJJJJJJJJJJJJ
2222222222222222222

JJ JJ JJ J JJ JJ JJ J J J
J J J

Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode

Type CR-M012DC2L CR-M012DC2LD CR-M024DC2L CR-M024DC2LD CR-M048DC2L CR-M048DC2LD CR-M060DC2L CR-M110DC2L CR-M110DC2LD CR-M125DC2L CR-M125DC2LD CR-M220DC2L CR-M220DC2LD CR-M012AC2L CR-M024AC2L CR-M048AC2L CR-M110AC2L CR-M120AC2L CR-M230AC2L

Order code 1SVR405611R4100 1SVR405611R4400 1SVR405611R1100 1SVR405611R1400 1SVR405611R6100 1SVR405611R6400 1SVR405611R4300 1SVR405611R8100 1SVR405611R8400 1SVR405611R8300 1SVR405611R8500 1SVR405611R9100 1SVR405611R9400 1SVR405611R0300 1SVR405611R0300 1SVR405611R5100 1SVR405611R7100 1SVR405611R2100 1SVR405611R3100

-- CR-M pluggable relays with LED

-- Pluggable interface relays and optocouplers Selection table CR-M range

375

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

JJJ

JJJ

JJJJJJJJJJJJJJJJJJJ

3333333333333333333

JJJJJJJJJJJJJJJJJJJ

JJ JJ JJ J JJ JJ JJ J J J
J J J

Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode

Type CR-M012DC3L CR-M012DC3LD CR-M024DC3L CR-M024DC3LD CR-M048DC3L CR-M048DC3LD CR-M060DC3L CR-M110DC3L CR-M110DC3LD CR-M125DC3L CR-M125DC3LD CR-M220DC3L CR-M220DC3LD CR-M012AC3L CR-M024AC3L CR-M048AC3L CR-M110AC3L CR-M120AC3L CR-M230AC3L

Order code 1SVR405612R4100 1SVR405612R4400 1SVR405612R1100 1SVR405612R1400 1SVR405612R6100 1SVR405612R6400 1SVR405612R4300 1SVR405612R8100 1SVR405612R8400 1SVR405612R8300 1SVR405612R8500 1SVR405612R9100 1SVR405612R9400 1SVR405612R0300 1SVR405612R0100 1SVR405612R5100 1SVR405612R7100 1SVR405612R2100 1SVR405612R3100

-- CR-M pluggable relays with LED

-- Pluggable interface relays and optocouplers Selection table CR-M range

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

376

JJJ

JJJ

JJJJJJJJJJJJJJJJJJJ

4444444444444444444

JJ JJ JJ J JJ JJ JJ J J J
J J J
JJJJJJJJJJJJJJJJJJJ

Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode

Type CR-M012DC4L CR-M012DC4LD CR-M024DC4L CR-M024DC4LD CR-M048DC4L CR-M048DC4LD CR-M060DC4L CR-M110DC4L CR-M110DC4LD CR-M125DC4L CR-M125DC4LD CR-M220DC4L CR-M220DC4LD CR-M012AC4L CR-M024AC4L CR-M048AC4L CR-M110AC4L CR-M120AC4L CR-M230AC4L

Order code 1SVR405613R4100 1SVR405613R4400 1SVR405613R1100 1SVR405614R1100 1SVR405613R6100 1SVR405613R6400 1SVR405613R4300 1SVR405613R8100 1SVR405613R8400 1SVR405613R8300 1SVR405613R8500 1SVR405613R9100 1SVR405613R9400 1SVR405613R0300 1SVR405613R0100 1SVR405613R5100 1SVR405613R7100 1SVR405613R2100 1SVR405613R3100

-- CR-M pluggable relays with LED

-- Pluggable interface relays and optocouplers Selection table CR-M range

377

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

4444444444444444444
JJJJJJJJJJJJJJJJJJJ
JJJJJJJJJJJJJ JJ

JJJJJJJJJJJJJJJJJJJ

J J J

J JJ

Input voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode

J

J

J

J

J

J

J

J

J

J

J

J

J

Type CR-M024DC4G CR-M024AC4G CR-M110AC4G CR-M230AC4G CR-M230AC4G CR-M012DC4LG CR-M024DC4LG CR-M048DC4LG CR-M060DC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG CR-M024AC4LG CR-M048AC4LG CR-M110AC4LG CR-M120AC4LG CR-M230AC4LG CR-M012DC4LDG CR-M024DC4LDG

Order code 1SVR405618R1000 1SVR405618R0000 1SVR405618R7000 1SVR405618R3000 1SVR405618R3000 1SVR405618R4100 1SVR405618R1100 1SVR405618R6100 1SVR405618R4300 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 1SVR405618R0100 1SVR405618R5100 1SVR405618R7100 1SVR405618R2100 1SVR405618R3100 1SVR405618R4400 1SVR405618R1400

-- CR-M pluggable relays with Gold Plated Contacts

-- Pluggable interface relays and optocouplers Selection table CR-M range

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

378

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

379

-- Pluggable interface relays and optocouplers Selection table CR-M range complete versions

-- CR-M range complete versions

1SVR405618R3111

1SVR405618R3110

CR-M230AC4GSS92CV 1SVR405618R3112

1SVR405613R3012

CR-M230AC4LS92CV 1SVR405613R3011

CR-M230AC4SS92CV 1SVR405613R3110

CR-M024AC4LS62CV 1SVR405613R0010

CR-M024DC4LDGSS 1SVR405618R1410

CR-M024DC4LGLC22 1SVR405618R1110

CR-M024DC4GLC62CV 1SVR405618R1010

CR-M024DC4GSS42V 1SVR405618R1011

1SVR405613R1012

CR-M024DC4LS42V 1SVR405613R1011

CR-M024DC4SS42V 1SVR405613R1010

CR-M012DC4LDGSS 1SVR405618R4410

Order code

CR-M230AC4LGSS

CR-M230AC4LGLC

CR-M230AC4LC92

CR-M024DC4LC42

Type

Input voltage 12 V DC 24 V DC 48 V DC
60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 6 A 250 V 10 A 250 V 12 A Output contacts c/o Gold plated contacts Socket type Standard socket Logical socket Additional features LED Free-wheeling diode

J JJJJJJJ

J

JJJJJJ JJJJJJJJJJJJJJJ

444444444444444

J

JJJJ

JJJ

JJ J J J J J JJ JJ J JJ J

JJJJJJJJJJJJJJJ

JJJJJ JJ

JJ

380

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- List of components Selection table CR-M range complete versions

The complete versions of the CR-M range comprise of a pluggable interface relay, socket, holder, marker and where applicable a function module.

-- CR-M complete versions

Relay

Socket Function module

Holder

Order code 1SVR405618R4400 1SVR405613R1000 1SVR405618R1000 1SVR405618R1100 1SVR405618R1400 1SVR405613R0000 1SVR405613R3000 1SVR405618R3000 1SVR405618R3100 1SVR405651R3000 1SVR405651R3100 1SVR405651R3200 1SVR405651R0000 1SVR405652R0000 1SVR405652R1000 1SVR405652R9100 1SVR405655R1000 1SVR405654R0100 1SVR405655R1100 1SVR405659R1000

Type CR-M012DC4LDG CR-M024DC4 CR-M024DC4G CR-M024DC4LG CR-M024DC4LDG CR-M024AC4 CR-M230AC4 CR-M230AC4G CR-M230AC4LG CR-M4SS CR-M4LS CR-M4LC CR-P/M 22 CR-P/M 42 CR-P/M 42V CR-P/M 42CV CR-P/M 62CV CR-P/M 92 CR-P/M 92CV CR-MH

Complete versions Order code 1SVR405618R4410 1SVR405613R1010 1SVR405613R1011 1SVR405613R1012 1SVR405618R1011 1SVR405618R1010 1SVR405618R1110 1SVR405618R1410 1SVR405613R0010 1SVR405613R3110 1SVR405613R3011 1SVR405613R3012 1SVR405618R3112 1SVR405618R3110 1SVR405618R3111

Type CR-M012DC4LDGSS CR-M024DC4SS42V CR-M024DC4LS42V CR-M024DC4LC42 CR-M024DC4GSS42V CR-M024DC4GLC62CV CR-M024DC4LGLC22 CR-M024DC4LDGSS CR-M024AC4LS62CV CR-M230AC4SS92CV CR-M230AC4LS92CV CR-M230AC4LC92 CR-M230AC4GSS92CV CR-M230AC4LGLC CR-M230AC4LGSS

J

J

J

J

J

J

J

J

J

JJ

J

J

J

J

J

J

JJ

J

J

J

J

J

J

J

J

J

J

JJ

J

J

JJ

J

J

J

J

J

J

J

J

J

J

J

JJ

JJ

JJ

JJ

J

J

JJJJJJ

JJJ

JJJJJJ

JJJ

JJJ

JJJJJJ

JJJJJJ

JJJ

J JJJJJJ

J

Related control supply voltage 6-220 V DC 6-24 V DC 24-60 V DC 110 V DC 110-230 V DC 6-24 V AC 24-60 V AC 110-230 V AC 24 V AC 115 V AC 230 V AC 24-240 V AC/DC Function Diode - reverse polarity protection / free-wheeling diode Diode and LED - reverse polarity protection / free-wheeling diode RC element - spark quenching Diode and LED Varistor and LED - overvoltage protection Varistor - overvoltage protection LED red LED green

J

J

JJ

JJ

J

JJ

JJ

J

JJ

J JJ

JJ

JJ

J

JJ

JJ

JJ

JJJ

JJ

JJ

JJ

J

Type CR-P/M 22 CR-P/M 42 CR-P/M 42V CR-P/M 42B CR-P/M 42BV CR-P/M 42C CR-P/M 42CV CR-P/M 52B CR-P/M 52D CR-P/M 52C CR-P/M 62 CR-P/M 62V CR-P/M 62E CR-P/M 62EV CR-P/M 92 CR-P/M 92V CR-P/M 62C CR-P/M 62CV CR-P/M 62D CR-P/M 62DV CR-P/M 92C CR-P/M 92CV CR-P/M 72 CR-P/M 72A CR-P/M 82

Order code 1SVR405651R0000 1SVR405652R0000 1SVR405652R1000 1SVR405652R4000 1SVR405652R4100 1SVR405652R9000 1SVR405652R9100 1SVR405653R0000 1SVR405653R4000 1SVR405653R1000 1SVR405654R0000 1SVR405654R1000 1SVR405654R4000 1SVR405654R4100 1SVR405654R0100 1SVR405654R1100 1SVR405655R0000 1SVR405655R1000 1SVR405655R4000 1SVR405655R4100 1SVR405655R0100 1SVR405655R1100 1SVR405656R0000 1SVR405656R1000 1SVR405656R2000

-- CR-P/M function modules

-- Pluggable interface relays and optocouplers Selection table CR-P/M function modules

381

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

2222222222333333333333

JJJJJJJJJJJJJJJJJJJJJJ

J J J J J J

J J
J J J

Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 10 A Output contacts c/o Gold plated contacts

J J J J J J

J J J J
J

Type CR-U012DC2 CR-U024DC2 CR-U048DC2 CR-U110DC2 CR-U220DC2 CR-U024AC2 CR-U048AC2 CR-U110AC2 CR-U120AC2 CR-U230AC2 CR-U012DC3 CR-U024DC3 CR-U048DC3 CR-U110DC3 CR-U125DC3 CR-U220DC3 CR-U024AC3 CR-U048AC3 CR-U060AC3 CR-U110AC3 CR-U120AC3 CR-U230AC3

Order code 1SVR405621R4000 1SVR405621R1000 1SVR405621R6000 1SVR405621R8000 1SVR405621R9000 1SVR405621R0000 1SVR405621R5000 1SVR405621R7000 1SVR405621R2000 1SVR405621R3000 1SVR405622R4000 1SVR405622R1000 1SVR405622R6000 1SVR405622R8000 1SVR405622R8200 1SVR405622R9000 1SVR405622R0000 1SVR405622R5000 1SVR405622R5200 1SVR405622R7000 1SVR405622R2000 1SVR405622R3000

-- CR-U pluggable relays without LED

-- Pluggable interface relays and optocouplers Selection table CR-U range

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

382

JJJJ

JJJJ

JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ

2222222222 2 2222333333333333333

JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ

J J J

J J J

Input voltage 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC Output rating 250 V 10 A Output contacts c/o Gold plated contacts Additional features LED Free-wheeling diode

JJ JJ JJ J J J J J J

JJ JJ JJ JJ
J J J J

Type CR-U012DC2L CR-U012DC2LD CR-U024DC2L CR-U024DC2LD CR-U048DC2L CR-U048DC2LD CR-U110DC2L CR-U110DC2LD CR-U220DC2L CR-U012AC2L CR-U024AC2L CR-U048AC2L CR-U110AC2L CR-U120AC2L CR-U230AC2L CR-U012DC3L CR-U012DC3LD CR-U024DC3L CR-U024DC3LD CR-U048DC3L CR-U048DC3LD CR-U110DC3L CR-U110DC3LD CR-U220DC3L CR-U012AC3L CR-U024AC3L CR-U048AC3L CR-U110AC3L CR-U120AC3L CR-U230AC3L

Order code 1SVR405621R4100 1SVR405621R4400 1SVR405621R1100 1SVR405621R1400 1SVR405621R6100 1SVR405621R6400 1SVR405621R8100 1SVR405621R8400 1SVR405621R9100 1SVR405621R0300 1SVR405621R0100 1SVR405621R5100 1SVR405621R7100 1SVR405621R2100 1SVR405621R3100 1SVR405622R4100 1SVR405622R4400 1SVR405622R1100 1SVR405623R1100 1SVR405622R6100 1SVR405622R6400 1SVR405622R8100 1SVR405622R8400 1SVR405622R9100 1SVR405622R0300 1SVR405622R0100 1SVR405622R5100 1SVR405622R7100 1SVR405622R2100 1SVR405622R3100

-- CR-U pluggable relays with LED

-- Pluggable interface relays and optocouplers Selection table CR-U range

383

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

384

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Selection table CR-U function modules

-- CR-U function modules

Order code 1SVR405661R0000 1SVR405662R0000 1SVR405662R1000 1SVR405662R4000 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405663R0000 1SVR405663R4000 1SVR405663R1000 1SVR405664R0000 1SVR405664R1000 1SVR405664R4000 1SVR405664R4100 1SVR405664R0100 1SVR405664R1100 1SVR405665R0000 1SVR405665R1000 1SVR405665R4000 1SVR405665R4100 1SVR405665R0100 1SVR405665R1100 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 1SVR405677R0000

Type CR-U 21 CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV CR-U 51B CR-U 51D CR-U 51C CR-U 61 CR-U 61V CR-U 61E CR-U 61EV CR-U 91 CR-U 91V CR-U 61C CR-U 61CV CR-U 61D CR-U 61DV CR-U 91C CR-U 91CV CR-U 71 CR-U 71A CR-U 81 CR-U T

Related control supply voltage 6-220 V DC 6-24 V DC 24-60 V DC 110 V DC 110-230 V DC 6-24 V AC 24-60 V AC 110-230 V AC 24 V AC 115 V AC 230 V AC 24-240 V AC/DC Function Diode - reverse polarity protection / free wheeling diode Diode and LED - Reverse polarity protection / free-wheeling diode and LED to indicate energized coil RC element - Spark quenching Diode and LED - LED to indicate energized coil Varistor and LED - Overvoltage protection and LED to indicate energized coil Varistor - Overvoltage protection Multi-function time module LED red LED green

J

JJ

J JJ

JJ

JJ

J

JJ

JJ

JJ

J

JJ

JJ

J JJ

JJ

J

JJ

JJ

J

JJ

JJ

J

J

J

J

J

JJJJJJ

JJJ JJJJJJ

JJJJJJ

JJJ JJJ

JJJ

J

JJJJJJ

JJJJJJ

J

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

385

-- Pluggable interface relays and optocouplers Benefits and advantages

ABB's interface relays and optocouplers ensure a reliable voltage conversion between process peripherals and higher level control systems. These relays ensure reliable signal switching and provide electrical isolation for sensitive electronics such as PLCs. The wide variety of pluggable interface relays with accompanied by standard or logic sockets may be used for switching AC or DC loads. Suitable for extreme environments, ABB's interface relays are offered across a wide spectrum of coil voltages, with a variety of optional function modules.

Continuous operation

The interface relay portfolio incorporates a large assortment of relays. It includes both electromechanical relays and optocouplers. Optocouplers allow for continuous operation without any mechanical wear-and -tear.

Easy to install

The interface relay includes both pluggable and non-pluggable relays. The plugggable relays allow for the easy and seamless exchange of relay modules.

The ABB interface relays and optocouplers are approved for a large variety of applications, comply to Global availability the highest global approvals and are available world-wide.

386

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Socket and terminal connection types

Standard sockets

-- 01 Standard socket CR-P
Logical sockets

2CDC291040F0004 2CDC291009S0011

-- 02 Standard socket CR-M

Position of connection terminals: Coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket.

Position of connection terminals: Coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on the upper side of the socket.

2CDC291006S0011 2CDC291042F0004

-- 03 Logical socket CR-P

-- 04 Logical socket CR-M

Terminal connection types

-- 05 Screw type

-- 06 Spring type

-- 07 Fork type

A variety of sockets are available for interface relays and optocouplers to meet the needs of different applications such as vibration- intensive environments.

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

387

-- Pluggable interface relays and optocouplers Relay components

-- CR-S range

Socket Marker Pluggable interface relay LED

-- CR-P range

Socket Pluggable function module Pluggable interface relay Plastic holder Marker

388

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Relay components

-- CR-M range

Socket

-- CR-U range

Pluggable function module Test button Pluggable interface relay Holder Marker
Socket
Pluggable function module Test button Pluggable interface relay Holder

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

389

-- Pluggable interface relays and optocouplers Ordering details ­ CR-S range

CR-S relay
CR-S optocoupler CR-S complete interface relay

2CDC 291 003 S0016

2CDC292008F0016

2CDC 291 005 S0014

The slim pluggable interface relays and optocouplers of the CR-S range may be used for electrical isolation, amplification and signal matching. The CR-S relays are 6.2 mm wide and therefore allow for the switching high currents on a small footprint.

-- Ordering details - CR-S range pluggable interface relays

Rated control Outputs supply voltage

Contact ratings Type

Order code

5 V DC 12 V DC 24 V DC 48 V DC 60 V DC 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC

1 c/o (SPDT) standard contacts

250 V, 6 A

1 c/o (SPDT) gold plated contacts

12 V, 250 mA (3W)1)

CR-S005VDC1R CR-S012VDC1R CR-S024VDC1R CR-S048VDC1R CR-S060VDC1R CR-S005VDC1RG CR-S012VDC1RG CR-S024VDC1RG CR-S048VDC1RG CR-S060VDC1RG

1SVR405501R1010 1SVR405501R2010 1SVR405501R3010 1SVR405501R4010 1SVR405501R5010 1SVR405501R1020 1SVR405501R2020 1SVR405501R3020 1SVR405501R4020 1SVR405501R5020

Pkg Weight (1 pc.)
qty kg (lb) 10 0.005
(0.011)
10 0.005 (0.011)

-- Ordering details - CR-S range pluggable optocouplers

Rated control Outputs supply voltage

Type

24 V DC

Transistor, 100 mA - 48 V DC MOS-FET, 2 A - 24 V DC Triac, 2 A - 240 V AC

CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1TRI

Order code
1SVR405510R3050 1SVR405510R3060 1SVR405510R3070

Pkg Weight (1 pc.)
qty kg (lb)
10 0.004 (0.009)

-- Ordering details - CR-S range complete interface relays (relay + socket)

Rated control Outputs Contact ratings Type supply voltage

Order code

24 V AC/DC 110 V AC/DC 230 V AC/DC 24 V AC/DC 110 V AC/DC 230 V AC/DC

1 c/o (SPDT) standard contacts

250 V, 6 A

1 c/o (SPDT) gold plated contacts

12 V, 250 mA (3W)1)

CR-S024VADC1CRS CR-S024VADC1CRZ CR-S110VADC1CRS CR-S110VADC1CRZ CR-S230VADC1CRS CR-S230VADC1CRZ CR-S024VADC1CRGS CR-S024VADC1CRGZ CR-S110VADC1CRGS CR-S110VADC1CRGZ CR-S230VADC1CRGS CR-S230VADC1CRGZ

1SVR405541R3110 1SVR405541R3210 1SVR405541R6110 1SVR405541R6210 1SVR405541R7110 1SVR405541R7210 1SVR405541R3120 1SVR405541R3220 1SVR405541R6120 1SVR405541R6220 1SVR405541R7120 1SVR405541R7220

Pkg Weight (1 pc.)
qty kg (lb) 10 0.03
(0.066)
10 0.03 (0.066)

1) If specified maximum values exceeded, the gold plating is destroyed. The maximum values of the standard contacts are then valid.

390

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-S range

CR-S socket

2CDC292008F0016

-- Ordering details - CR-S range sockets

Rated control Connection type supply voltage

Type

6-24 V DC
12-24 V AC/DC
48-60 V AC/DC
110-125 V AC/DC 220-240 V AC/DC

screw spring screw spring screw spring screw spring screw spring

CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SZ

-- Ordering details - CR-S range accessories

Version

Type

Order code
1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405521R5100 1SVR405521R5200 1SVR405521R6100 1SVR405521R6200 1SVR405521R7100 1SVR405521R7200
Order code

Jumper bar 20 pole, blue color Jumper bar 20 pole, red color Jumper bar 20 pole, black color Separator

CR-SJB20-BLUE CR-SJB20-RED CR-SJB20-BLACK CR-SSEP

1SVR405598R0700 1SVR405598R0800 1SVR405598R0900 1SVR405599R0000

Pkg Weight (1 pc.)
qty kg (lb)

10

0.025

(0.055)

Pkg Weight (1 pc.)
qty kg (lb)

10

0.008

(0.018)

10

0.012

(0.026)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

391

-- Pluggable interface relays and optocouplers Ordering details ­ CR-S range

-- Relay assemblies

Control voltage 5 V DC
12 V DC

Connection terminal screw
spring
screw

Contact material standard gold plated standard gold plated standard

gold plated

spring

standard

gold plated

12 V AC 24 V DC

screw spring screw

standard gold plated standard gold plated standard

gold plated

spring

standard

gold plated

24 V AC

screw

spring

48 V AC/DC

screw

spring

60 V AC/DC

screw

spring

110-125 V AC/DC screw

spring

220-240 V AC/DC screw

spring

standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated standard gold plated

Socket type

Socket order code

Relay type

Relay order code

CR-S006/024VDC1SS CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S006/024VDC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SS or CR-S012/024VADC1SS CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S006/024VDC1SZ or CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S220/240VADC1SZ

1SVR405521R1100 1SVR405521R1100 1SVR405521R1200 1SVR405521R1200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1100 or 1SVR405521R3100 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R1200 or 1SVR405521R3200 1SVR405521R3100 1SVR405521R3100 1SVR405521R3200 1SVR405521R3200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R5100 1SVR405521R5100 1SVR405521R5200 1SVR405521R5200 1SVR405521R6100 1SVR405521R6100 1SVR405521R6200 1SVR405521R6200 1SVR405521R7100 1SVR405521R7100 1SVR405521R7200 1SVR405521R7200

CR-S005VDC1R CR-S005VDC1RG CR-S005VDC1R CR-S005VDC1RG CR-S012VDC1R
CR-S012VDC1RG
CR-S012VDC1R
CR-S012VDC1RG
CR-S012VDC1R CR-S012VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S024VDC1R
CR-S024VDC1RG
CR-S024VDC1R
CR-S024VDC1RG
CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S060VDC1R CR-S060VDC1RG

1SVR405501R1010 1SVR405501R1020 1SVR405501R1010 1SVR405501R1020 1SVR405501R2010
1SVR405501R2020
1SVR405501R2010
1SVR405501R2020
1SVR405501R2010 1SVR405501R2020 1SVR405501R2010 1SVR405501R2020 1SVR405501R3010
1SVR405501R3020
1SVR405501R3010
1SVR405501R3020
1SVR405501R3010 1SVR405501R3020 1SVR405501R3010 1SVR405501R3020 1SVR405501R4010 1SVR405501R4020 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020 1SVR405501R5010 1SVR405501R5020

392

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-S range

-- Optocoupler assemblies

Control voltage 24 V DC

Connection terminal screw spring screw spring screw spring

Output characteristics Transistor 100 mA - 48 V DC
MOS-FET 2 A - 24 V DC
Triac 2 A - 240 V AC

Socket type

Socket order code

CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ

1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200 1SVR405521R3100 1SVR405521R3200

Opto type
CR-S024VDC1TRA CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1MOS CR-S024VDC1TRI CR-S024VDC1TRI

Opto order code
1SVR405510R3050 1SVR405510R3050 1SVR405510R3060 1SVR405510R3060 1SVR405510R3070 1SVR405510R3070

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

393

-- Pluggable interface relays and optocouplers Ordering details ­ CR-P range

CR-P relay CR-P optocoupler

2CDC 291 006 S0016

2CDC 291 045 F0004

The CR-P range offers the highest current switching in an IP67 rated relay housing. This range comprises of pluggable interface relays and optocouplers offered in 10 different control supply voltages. Additionally, gold plated contacts are available for applications where sensitive signals are to be switched. The CR-P range also includes complete versions consisting of a relay, socket, holder, marker and function module.

-- Ordering details - CR-P range relays
Rated control Outputs Contact ratings supply voltage

Type

12 V DC 24 V DC 48 V DC 110 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

1 c/o (SPDT)

250 V, 16 A

2 c/o (SPDT)

250 V, 8 A

CR-P012DC1 CR-P024DC1 CR-P048DC1 CR-P110DC1 CR-P024AC1 CR-P048AC1 CR-P110AC1 CR-P120AC1 CR-P230AC1 CR-P012DC2 CR-P024DC2 CR-P048DC2 CR-P110DC2 CR-P012AC2 CR-P024AC2 CR-P048AC2 CR-P110AC2 CR-P120AC2 CR-P230AC2

Order code
1SVR405600R4000 1SVR405600R1000 1SVR405600R6000 1SVR405600R8000 1SVR405600R0000 1SVR405600R5000 1SVR405600R7000 1SVR405600R2000 1SVR405600R3000 1SVR405601R4000 1SVR405601R1000 1SVR405601R6000 1SVR405601R8000 1SVR405601R0200 1SVR405601R0000 1SVR405601R5000 1SVR405601R7000 1SVR405601R2000 1SVR405601R3000

Pkg Weight (1 pc.)
qty kg (lb)

10

0.014

(0.031)

10

0.014

(0.031)

-- Ordering details - CR-P range relays with gold contacts

Rated control Outputs Contact ratings Type supply voltage

Order code

24 V DC 24 V AC 110 V AC 230 V AC

2 c/o (SPDT) gold contact

250 V, 8 A

CR-P024DC2G CR-P024AC2G CR-P110AC2G CR-P230AC2G

1SVR405606R1000 1SVR405606R0000 1SVR405606R7000 1SVR405606R3000

Pkg Weight (1 pc.)
qty kg (lb)

10

0.014

(0.031)

-- Ordering details - CR-P range pluggable optocouplers

Rated control supply voltage (Us)
10-32 V DC

Outputs
MOS-FET, 5 A - 35 V DC Triac, 3 A - 275 V AC

Type

Order code

CR-P024MOS1 CR-P024TRI1

1SVR405610R4060 1SVR405610R4070

Pkg Weight (1 pc.)
qty kg (lb)

10

0.011

(0.618)

394

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-P range

CR-PLSX CR-PSS CR-PJ

2CDC291040F0004

2CDC 291 004 F0007

2CDC291088F0004

Standard and logical sockets for CR-P interface relays are suitable for snap-on mounting onto a DIN rail. Optional function modules for the CR-P range are plugged into both standard and logical sockets.

-- Ordering details - Sockets*

Version

Connection terminal

Type

Order code

Logical socket with protective separation Logical socket
Standard socket

screw screw spring screw

*All CR-P socket packages include a set of markers.

CR-PLS CR-PLSX CR-PLC CR-PSS

1SVR405650R0000 1SVR405650R0100 1SVR405650R0200 1SVR405650R1000

Pkg Weight (1 pc.)
qty kg (lb)
10 0.045 (0.099)
0.043 (0.095)
0.042 (0.093)
0.038 (0.084)

Standard sockets
Position of connection terminals: coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket.

Logical sockets Position of connection terminals: coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on the upper side of the socket.

-- Ordering details - Accessories
Version
Plastic holder for socket Metal holder for socket Jumper bar for sockets with screw connection Marker

Type
CR-PH CR-PH1 CR-PJ CR-PM

Order code
1SVR405659R0000 1SVR405659R0100 1SVR405658R5000 1SVR405658R0000

Pkg Weight (1 pc.)
qty kg (lb)
10 0.002 (0.004)
0.4g
0.018 (0.040)
10 0.0002 (0.0004)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

395

-- Pluggable interface relays and optocouplers Ordering details ­ CR-P range

CR-P complete version

2CDC291001F0019

-- Ordering details - CR-P range complete versions

Rated control supply voltage 12 V DC
24 V DC
110 V DC
24 V AC 120 V AC 230 V AC

Out- Description puts

Socket Connection Type

type

terminal

Order code

Pkg Weight (1 pc.)
qty kg (lb)

1 c/o

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

1 c/o

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

Reverse polarity protection and freewheeling diode, LED green, holder

logical

spring

Varistor and LED red, holder

logical spring

1 c/o

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

1 c/o Varistor and

standard screw

LED green, holder

1 c/o Varistor and

standard screw

LED green, holder

1 c/o

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

Holder

logical screw

Varistor and

logical spring

LED green, holder

CR-P012DC1SS42V 1SVR405600R4010 10 0.057 (0.126)

CR-P024DC1SS42V 1SVR405600R1010 10 0.057 (0.126)

CR-P024DC1LC42V 1SVR405600R1011 10 0.057 (0.126)

CR-P024DC1LC62C 1SVR405600R1013 10 CR-P110DC1SS42CV 1SVR405600R8010 10

0.057 (0.126)
0.057 (0.126)

CR-P024AC1SS62CV 1SVR405600R0010 10 CR-P120AC1SS92CV 1SVR405600R2010 10 CR-P230AC1SS92CV 1SVR405600R3110 10

0.057 (0.126)
0.057 (0.126)
0.057 (0.126)

CR-P230AC1LS

1SVR405600R3011 10

CR-P230AC1LC92CV 1SVR405600R3010 10

0.057 (0.126)
0.057 (0.126)

396

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-P range

CR-P complete version

2CDC291001F0019

-- Ordering details - CR-P range complete versions

Rated control supply voltage 12 V DC 24 V DC
24 V DC
110 V DC 24 V AC 120 V AC 230 V AC
230 V AC

Outputs 2 c/o 2 c/o
2 c/o gold plated
2 c/o 2 c/o 2 c/o 2 c/o
2 c/o gold plated

Description

Socket type

Connection terminal

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

Reverse polarity protection and freewheeling diode, LED red, holder

logical screw

Reverse polarity protection and freewheeling diode, LED green, holder

logical

screw

Reverse polarity protection and freewheeling diode, LED red, holder

logical spring

Reverse polarity protection and freewheeling diode, LED green, holder

logical

spring

Varistor and LED logical spring red, holder

Varistor and LED logical spring green, holder

Reverse polarity protection and freewheeling diode, LED green, holder

standard screw

Varistor and

standard screw

LED green, holder

Varistor and

standard screw

LED green, holder

Reverse polarity standard screw protection and freewheeling diode, LED green, holder

Varistor and

logical screw

LED green, holder

Diode and LED red, holder

logical spring

Diode and LED red, holder

logical spring

Varistor and LED red, holder

logical spring

Varistor and

logical spring

LED green, holder

Type

Order code

Pkg Weight (1 pc.)
qty kg (lb)

CR-P012DC2SS42V 1SVR405601R4010 10 0.057 (0.126)

CR-P024DC2SS42V 1SVR405601R1010 10 0.057 (0.126)

CR-P024DC2LS42 1SVR405601R1013 10 0.057 (0.126)

CR-P024DC2LS42V 1SVR405601R1011 10 0.057 (0.126)

CR-P024DC2LC42 1SVR405601R1012 10 0.057 (0.126)

CR-P024DC2GLC42V 1SVR405606R1010 10 0.057 (0.126)

CR-P024DC2GLC62C 1SVR405606R1013 10 CR-P024DC2GLC62CV 1SVR405606R1011 10 CR-P110DC2SS42CV 1SVR405601R8010 10

0.057 (0.126)
0.057 (0.126)
0.057 (0.126)

CR-P024AC2SS62CV 1SVR405601R0010 10 CR-P120AC2SS92CV 1SVR405601R2010 10 CR-P230AC2SS92CV 1SVR405601R3110 10

0.057 (0.126)
0.057 (0.126)
0.057 (0.126)

CR-P230AC2LS92CV 1SVR405601R3011 10 CR-P230AC2LC92 1SVR405601R3012 10 CR-P230AC2GLC92 1SVR405606R3013 10 CR-P230AC2GLC92C 1SVR405606R3012 10 CR-P230AC2GLC92CV 1SVR405606R3010 10

0.057 (0.126)
0.057 (0.126)
0.057 (0.126)
0.057 (0.126)
0.057 (0.126)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

397

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M

2CDC 291 002 F0015

The CR-M range offers the possibility of switching up to 4 different circuits with a single relay. The integrated LED and test button* allow for easy testing and commissioning. This range of relays are available at a wide range of different coil voltages and are accompanied by a wide variety of function modules. The CR-M range also includes complete versions consisting of a relay, socket, holder, marker and where applicable, function module.

-- Ordering details - CR-M range without LED

Rated control Outputs Contact

supply voltage

ratings

Type

12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

2 c/o (SPDT)

250 V, 12 A

3 c/o (SPDT)

250 V, 10 A

4 c/o (SPDT)

250 V, 6 A

CR-M012DC2 CR-M024DC2 CR-M048DC2 CR-M060DC2 CR-M110DC2 CR-M125DC2 CR-M220DC2 CR-M024AC2 CR-M048AC2 CR-M110AC2 CR-M120AC2 CR-M230AC2 CR-M012DC3 CR-M024DC3 CR-M048DC3 CR-M060DC3 CR-M110DC3 CR-M125DC3 CR-M220DC3 CR-M024AC3 CR-M048AC3 CR-M060AC3 CR-M110AC3 CR-M120AC3 CR-M230AC3 CR-M012DC4 CR-M024DC4 CR-M048DC4 CR-M060DC4 CR-M110DC4 CR-M125DC4 CR-M220DC4 CR-M024AC4 CR-M048AC4 CR-M110AC4 CR-M120AC4 CR-M230AC4

Order code
1SVR405611R4000 1SVR405611R1000 1SVR405611R6000 1SVR405611R4200 1SVR405611R8000 1SVR405611R8200 1SVR405611R9000 1SVR405611R0000 1SVR405611R5000 1SVR405611R7000 1SVR405611R2000 1SVR405611R3000 1SVR405612R4000 1SVR405612R1000 1SVR405612R6000 1SVR405612R4200 1SVR405612R8000 1SVR405612R8200 1SVR405612R9000 1SVR405612R0000 1SVR405612R5000 1SVR405612R5200 1SVR405612R7000 1SVR405612R2000 1SVR405612R3000 1SVR405613R4000 1SVR405613R1000 1SVR405613R6000 1SVR405613R4200 1SVR405613R8000 1SVR405613R8200 1SVR405613R9000 1SVR405613R0000 1SVR405613R5000 1SVR405613R7000 1SVR405613R2000 1SVR405613R3000

Pkg Weight (1 pc.)
qty kg (lb) 10 0.033
(0.073)
10 0.033 (0.073)
10 0.033 (0.073)

* Note: During the operation of the relay, the temperature of the test button will increase. In order to manually operate the test button, the supply voltage should first be disconnected. The test button is only safe to operate once it has cooled down or by using protective gloves and insulated tools. During operation, the test button should be pressed smoothly and quickly. When the test button is depressed, the n/o contacts will close and remain closed. Once the button is released, the n/o contacts change status and open. A 90 degree rotation of the test button closes and holds the n/o contacts in a closed position. Reverse rotation of the test button will once again change the status of the n/o contacts to their default open position.

398

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M

2CDC 291 002 F0015

-- Ordering details - CR-M range with LED

Rated control supply voltage 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

Outputs Contact ratings Type

Order code

2 c/o (SPDT)

250 V, 12 A

3 c/o (SPDT)

250 V, 10 A

4 c/o (SPDT)

250 V, 6 A

CR-M012DC2L CR-M024DC2L CR-M048DC2L CR-M060DC2L CR-M110DC2L CR-M125DC2L CR-M220DC2L CR-M012AC2L CR-M024AC2L CR-M048AC2L CR-M110AC2L CR-M120AC2L CR-M230AC2L CR-M012DC3L CR-M024DC3L CR-M048DC3L CR-M060DC3L CR-M110DC3L CR-M125DC3L CR-M220DC3L CR-M012AC3L CR-M024AC3L CR-M048AC3L CR-M110AC3L CR-M120AC3L CR-M230AC3L CR-M012DC4L CR-M024DC4L CR-M048DC4L CR-M060DC4L CR-M110DC4L CR-M125DC4L CR-M220DC4L CR-M012AC4L CR-M024AC4L CR-M048AC4L CR-M110AC4L CR-M120AC4L CR-M230AC4L

1SVR405611R4100 1SVR405611R1100 1SVR405611R6100 1SVR405611R4300 1SVR405611R8100 1SVR405611R8300 1SVR405611R9100 1SVR405611R0300 1SVR405611R0100 1SVR405611R5100 1SVR405611R7100 1SVR405611R2100 1SVR405611R3100 1SVR405612R4100 1SVR405612R1100 1SVR405612R6100 1SVR405612R4300 1SVR405612R8100 1SVR405612R8300 1SVR405612R9100 1SVR405612R0300 1SVR405612R0100 1SVR405612R5100 1SVR405612R7100 1SVR405612R2100 1SVR405612R3100 1SVR405613R4100 1SVR405613R1100 1SVR405613R6100 1SVR405613R4300 1SVR405613R8100 1SVR405613R8300 1SVR405613R9100 1SVR405613R0300 1SVR405613R0100 1SVR405613R5100 1SVR405613R7100 1SVR405613R2100 1SVR405613R3100

Pkg Weight (1 pc.)
qty kg (lb) 10 0.033
(0.073)
10 0.033 (0.073)
10 0.033 (0.073)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

399

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M

2CDC 291 002 F0015

-- Ordering details - CR-M range with LED and free-wheeling diode

Rated control Outputs supply voltage

Contact ratings

Type

Order code

12 V DC 24 V DC

2 c/o (SPDT)

250 V, 6 A CR-M012DC2LD 1SVR405611R4400 CR-M024DC2LD 1SVR405611R1400

48 V DC

CR-M048DC2LD 1SVR405611R6400

110 V DC

CR-M110DC2LD 1SVR405611R8400

125 V DC

CR-M125DC2LD 1SVR405611R8500

220 V DC

CR-M220DC2LD 1SVR405611R9400

12 V DC 24 V DC

3 c/o (SPDT)

250 V, 10 A CR-M012DC3LD 1SVR405612R4400 CR-M024DC3LD 1SVR405612R1400

48 V DC

CR-M048DC3LD 1SVR405612R6400

110 V DC

CR-M110DC3LD 1SVR405612R8400

125 V DC

CR-M125DC3LD 1SVR405612R8500

220 V DC

CR-M220DC3LD 1SVR405612R9400

12 VDC 24 V DC

4 c/o (SPDT)

250 V, 6 A CR-M012DC4LD 1SVR405613R4400 CR-M024DC4LD 1SVR405614R1100

48 V DC

CR-M048DC4LD 1SVR405613R6400

110 V DC

CR-M110DC4LD 1SVR405613R8400

125 V DC

CR-M125DC4LD 1SVR405613R8500

220 V DC

CR-M220DC4LD 1SVR405613R9400

-- Ordering details - CR-M range with gold contacts

Rated control Outputs supply voltage

Contact ratings

Type

Order code

24 V DC 24 V AC 110 V AC 230 V AC

4 c/o (SPDT)

250 V, 6 A

CR-M024DC4G CR-M024AC4G CR-M110AC4G CR-M230AC4G

1SVR405618R1000 1SVR405618R0000 1SVR405618R7000 1SVR405618R3000

Pkg Weight (1 pc.)
qty kg (lb) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073) 10 0.033
(0.073)
Pkg Weight (1 pc.)
qty kg (lb) 10 0.033
(0.073)

400

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M

2CDC 291 002 F0015

-- Ordering details ­ CR-M range with gold contacts and LED

Rated control Outputs supply voltage

Contact Type ratings

Order code

12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

4 c/o (SPDT)

250 V / 6 A

CR-M012DC4LG CR-M024DC4LG CR-M048DC4LG CR-M060DC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG CR-M024AC4LG CR-M048AC4LG CR-M110AC4LG CR-M120AC4LG CR-M230AC4LG

1SVR405618R4100 1SVR405618R1100 1SVR405618R6100 1SVR405618R4300 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 1SVR405618R0100 1SVR405618R5100 1SVR405618R7100 1SVR405618R2100 1SVR405618R3100

Pkg Weight (1 pc.)
qty kg (lb)

10

0.033

(0.073)

10 0.033 (0.073)

-- Ordering details ­ CR-M range with gold contacts, LED and free-wheeling diode

Rated control Outputs Contact Type

Order code

Pkg

supply voltage

ratings

qty

12 V DC

4 c/o

250 V / 6 CR-M012DC4LDG 1SVR405618R4400

10

24 V DC

(SPDT)

A

CR-M024DC4LDG 1SVR405618R1400

Weight (1 pc.) kg (lb)
0.033 (0.073)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

401

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M complete version

2CDC291002F0019

-- Ordering details ­ CR-M range complete version

Rated control supply voltage

Outputs

Description

Socket type Connec- Type tion terminal

Order code

Pkg Weight (1 pc.)
qty kg (lb)

12 V DC 4 c/o LED red, holder standard goldplated

screw

CR-M012DC4LDGSS 1SVR405618R4410 10 0.0109 (0.024)

24 V DC

4 c/o

Reverse

standard

polarity

protection and

free-wheeling

diode,

LED green,

holder

screw

CR-M024DC4SS42V 1SVR405613R1010 10 0.0109 (0.024)

Reverse

logical

polarity

protection and

free-wheeling

diode,

LED green,

holder

screw

CR-M024DC4LS42V 1SVR405613R1011 10 0.0109 (0.024)

Reverse

logical

polarity

protection and

free-wheeling

diode,

LED red, holder

spring

CR-M024DC4LC42

1SVR405613R1012 10 0.0109 (0.024)

24 V DC

4 c/o Reverse

standard

gold- polarity

plated protection and

free-wheeling

diode,

LED green,

holder

screw

CR-M024DC4GSS42V 1SVR405618R1011 10 0.0109 (0.024)

Varistor, LED green, holder

logical

spring

CR-M024DC4GLC62CV 1SVR405618R1010 10 0.0109 (0.024)

LED, freewheeling diode, holder

logical

spring

CR-M024DC4LGLC22 1SVR405618R1110 10 0.0109 (0.024)

LED red, freewheeling diode, holder

standard

screw

CR-M024DC4LDGSS 1SVR405618R1410 10 0.0109 (0.024)

24 V AC 4 c/o Varistor and LED green, holder

logical

screw

CR-M024AC4LS62CV 1SVR405613R0010 10 0.0109 (0.024)

402

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M complete version

2CDC291002F0019

-- Ordering details ­ CR-M range complete version

Rated control supply voltage

Outputs

230 V AC 4 c/o

230 V AC 4 c/o goldplated

Description Socket Connection Type

type

terminal

Varistor, LED green, holder

standard screw

Varistor, LED green, holder

logical screw

Diode and LED red, holder

logical spring

Reverse

standard screw

polarity

protection and

free-wheeling

diode, LED

green, holder

LED red, holder logical screw

LED red, holder standard screw

CR-M230AC4SS92CV CR-M230AC4LS92CV CR-M230AC4LC92 CR-M230AC4GSS92CV
CR-M230AC4LGLC CR-M230AC4LGSS

Order code

Pkg Weight (1 pc.)

qty kg (lb)
1SVR405613R3110 10 0.0109 (0.024)

1SVR405613R3011 10 0.0109 (0.024)

1SVR405613R3012 10 0.0109 (0.024)

1SVR405618R3112 10 0.0109 (0.024)

1SVR405618R3110 10 1SVR405618R3111 10

0.0109 (0.024)
0.0109 (0.024)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

403

-- Pluggable interface relays and optocouplers Ordering details ­ CR-M range

CR-M2LS CR-M4SS
CR-MJ

2CDC 291 005 F0007

2CDC 291 009 F0011

2CDC291042F0004

Standard and logical sockets for CR-M interface relays are suitable for snap-on mounting onto a DIN rail. Optional function modules for the CR-M range are plugged into both standard and logical sockets.

-- Ordering details - Sockets*

Version

Connection terminal

Type

Logical socket for 2 c/o

screw

CR-M2LS

Logical socket for 3 c/o

CR-M3LS

Logical socket for 2/4 c/o

CR-M4LS

Logical socket for 2 c/o

spring

CR-M2LC

Logical socket for 2/4 c/o

CR-M4LC

Standard socket for 2 c/o

screw

CR-M2SS

Standard socket for 3 c/o

CR-M3SS

Standard socket for 2/4 c/o

CR-M4SS

Standard socket for 2 c/o

fork type

CR-M2SF

Standard socket for 2/4 c/o

CR-M4SF

*All CR-M socket packages include a set of markers.

Order code
1SVR405651R1100 1SVR405651R2100 1SVR405651R3100 1SVR405651R1200 1SVR405651R3200 1SVR405651R1000 1SVR405651R2000 1SVR405651R3000 1SVR405651R1300 1SVR405651R3300

Pkg Weight (1 pc.)
qty kg (lb)
10 0.055 (0.121)
0.062 (0.137)
0.066 (0.146)
10 0.065 (0.143)
0.066 (0.146)
10 0.066 (0.146)
0.068 (0.150)
0.070 (0.154)
10 0.040 (0.088)
0.048 (0.106)

Standard sockets
Position of connection terminals: coil connection (A1-A2) on lower side of the socket, contact connections (n/o and n/c contacts) on the lower and upper side of the socket.

Logical sockets Position of connection terminals: coil connection (A1-A2) on lower side of the socket, all contact connections (common contacts, n/o and n/c contacts) on upper side of the socket.

-- Ordering details - Accessories
Version
Plastic holder for socket
Metal holder for socket
Jumper bar for sockets with screw connection Marker for CR-M standard sockets
Plug for test button replacement

Type
CR-MH CR-MH1 CR-MJ CR-MM CR-MP

Order code
1SVR405659R1000 1SVR405659R1100 1SVR405658R6000 1SVR405658R1000 1SVR405658R2000

Pkg Weight (1 pc.)
qty kg (lb)
10 0.003 (0.007)
10 0.0005 (0.001)
10 0.029 (0.064)
10 0.0005 (0.001)
100 0.001 (0.002)

404

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-P/M function modules

CR-P/M ...

2CDC 291 005 S0011

-- Ordering details - Diode - Reverse polarity protection / free-wheeling diode

Rated control supply voltage Us
6-220 V DC

Version A1+, A2-

Type CR-P/M 22

Order code

Pkg

qty 1SVR405651R0000 10

Weight (1 pc.) kg (lb)
0.003 (0.007)

-- Ordering details - Diode and LED - Reverse polarity protection / free-wheeling diode and LED to indicate energized coil

Rated control supply voltage Us
6-24 V DC 6-24 V DC 24-60 V DC 24-60 V DC 110 V DC 110 V DC

Version
red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2-

Type

Order code

Pkg

qty

CR-P/M 42

1SVR405652R0000 10

CR-P/M 42 V

1SVR405652R1000

CR-P/M 42 B

1SVR405652R4000

CR-P/M 42 BV 1SVR405652R4100

CR-P/M 42 C

1SVR405652R9000

CR-P/M 42 CV 1SVR405652R9100

Weight (1 pc.) kg (lb)
0.003 (0.007)

-- Ordering details - RC element - Spark quenching

Rated control supply voltage Us

Version

Type

6-24 V AC/DC 24-60 V AC/DC 110-230 V AC/DC

CR-P/M 52B CR-P/M 52D CR-P/M 52C

Order code

Pkg

qty 1SVR405653R0000 10 1SVR405653R4000 1SVR405653R1000

Weight (1 pc.) kg (lb)
0.003 (0.007)

-- Ordering details - Diode and LED - LED to indicate energized coil

Rated control supply voltage Us
6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC

Version

Type

Order code

Pkg

qty

red, for DC: A1+, A2- CR-P/M 62

1SVR405654R0000 10

green, for DC: A1+, A2- CR-P/M 62 V

1SVR405654R1000

red, for DC: A1+, A2- CR-P/M 62 E

1SVR405654R4000

green, for DC: A1+, A2- CR-P/M 62 EV 1SVR405654R4100

red, for DC: A1+, A2- CR-P/M 92

1SVR405654R0100

green, for DC: A1+, A2- CR-P/M 92 V

1SVR405654R1100

Weight (1 pc.) kg (lb)
0.003 (0.007)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

405

-- Pluggable interface relays and optocouplers Ordering details ­ CR-P/M function modules

CR-P/M ...

2CDC 291 005 S0011

-- Ordering details - Varistor and LED - Overvoltage protection and LED to indicate energized coil

Rated control supply voltage Us
6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC

Version

Type

Order code

Pkg

qty

red, for DC: A1+, A2- CR-P/M 62 C

1SVR405655R0000 10

green, for DC: A1+, A2- CR-P/M 62 CV 1SVR405655R1000

red, for DC: A1+, A2- CR-P/M 62 D

1SVR405655R4000

green, for DC: A1+, A2- CR-P/M 62 DV 1SVR405655R4100

red, for DC: A1+, A2- CR-P/M 92 C

1SVR405655R0100

green, for DC: A1+, A2- CR-P/M 92 CV 1SVR405655R1100

Weight (1 pc.) kg (lb)
0.003 (0.007)

-- Ordering details - Varistor - Overvoltage protection

Rated control supply voltage Us

Version

Type

24 V AC 115 V AC 230 V AC

CR-P/M 72 CR-P/M 72 A CR-P/M 82

Order code

Pkg

qty 1SVR405656R0000 10 1SVR405656R1000 1SVR405656R2000

Weight (1 pc.) kg (lb)
0.002 (0.004)

406

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-U range

CR-U

2CDC 291 047 F0004

The CR-U range offers up to 3 change over contacts in single relay. The integrated LED and test
button* allow for easy testing and commissioning. This robust range of relays are available at a
wide range of different coil voltages and are accompanied by a wide variety of function
modules. -- Ordering details - CR-U range without LED

Rated control Outputs supply voltage

Contact ratings

12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC

2 c/o (SPDT) 250 V, 10 A 3 c/o (SPDT) 250 V, 10 A

Type

Order code

CR-U012DC2 CR-U024DC2 CR-U048DC2 CR-U110DC2 CR-U220DC2 CR-U024AC2 CR-U048AC2 CR-U110AC2 CR-U120AC2 CR-U230AC2 CR-U012DC3 CR-U024DC3 CR-U048DC3 CR-U110DC3 CR-U125DC3 CR-U220DC3 CR-U024AC3 CR-U048AC3 CR-U060AC3 CR-U110AC3 CR-U120AC3 CR-U230AC3

1SVR405621R4000 1SVR405621R1000 1SVR405621R6000 1SVR405621R8000 1SVR405621R9000 1SVR405621R0000 1SVR405621R5000 1SVR405621R7000 1SVR405621R2000 1SVR405621R3000 1SVR405622R4000 1SVR405622R1000 1SVR405622R6000 1SVR405622R8000 1SVR405622R8200 1SVR405622R9000 1SVR405622R0000 1SVR405622R5000 1SVR405622R5200 1SVR405622R7000 1SVR405622R2000 1SVR405622R3000

Pkg Weight (1 pc.)
qty kg (lb) 10 0.083
(0.183)
10 0.083 (0.183)

* Note: During the operation of the relay, the temperature of the test button will increase. In order to manually operate the test botton, the supply voltage should first be disconnected. The test button is only safe to operate once it has cooled down or by using protective gloves and insulated tools. During operation, the test button should be pressed smoothly and quickly. When the test button is depressed, the n/o contacts will close and remain closed. Once the button is released, the n/o contacts change status and open. A 90 degree rotation of the test button closes and holds the n/o contacts in a closed position. Reverse rotation of the test button will once again change the status of the n/o contacts to their default open position.

-- Ordering details - CR-U range with LED

Rated control Outputs supply voltage

Contact ratings

12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

2 c/o (SPDT) 250 V, 10 A

Type

Order code

CR-U012DC2L 1SVR405621R4100 CR-U024DC2L 1SVR405621R1100 CR-U048DC2L 1SVR405621R6100 CR-U110DC2L 1SVR405621R8100 CR-U220DC2L 1SVR405621R9100 CR-U012AC2L 1SVR405621R0300 CR-U024AC2L 1SVR405621R0100 CR-U048AC2L 1SVR405621R5100 CR-U110AC2L 1SVR405621R7100 CR-U120AC2L 1SVR405621R2100 CR-U230AC2L 1SVR405621R3100

Pkg Weight (1 pc.)
qty kg (lb)
10 0.083 (0.183)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

407

-- Pluggable interface relays and optocouplers Ordering details ­ CR-U range

CR-U CR-U2S

2CDC 291 007 S0011

2CDC 291 047 F0004

-- Ordering details - CR-U range with LED

Rated control Outputs supply voltage

Contact ratings

12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 12 V AC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

3 c/o (SPDT) 250 V, 10 A

Type

Order code

CR-U012DC3L 1SVR405622R4100 CR-U024DC3L 1SVR405622R1100 CR-U048DC3L 1SVR405622R6100 CR-U110DC3L 1SVR405622R8100 CR-U220DC3L 1SVR405622R9100 CR-U012AC3L 1SVR405622R0300 CR-U024AC3L 1SVR405622R0100 CR-U048AC3L 1SVR405622R5100 CR-U110AC3L 1SVR405622R7100 CR-U120AC3L 1SVR405622R2100 CR-U230AC3L 1SVR405622R3100

Pkg Weight (1 pc.)
qty kg (lb)
10 0.083 (0.183)

-- Ordering details - CR-U range with LED and free-wheeling diode

Rated control Outputs supply voltage

Contact ratings

Type

Order code

12 V DC 24 V DC

2 c/o (SPDT)

250 V, 10 A CR-U012DC2LD CR-U024DC2LD

1SVR405621R4400 1SVR405621R1400

48 V DC

CR-U048DC2LD

1SVR405621R6400

110 V DC

CR-U110DC2LD

1SVR405621R8400

12 V DC 24 V DC

3 c/o (SPDT)

CR-U012DC3LD CR-U024DC3LD

1SVR405622R4400 1SVR405623R1100

48 V DC

CR-U048DC3LD

1SVR405622R6400

110 V DC

CR-U110DC3LD

1SVR405622R8400

Pkg Weight (1 pc.)
qty kg (lb)
10 0.033 (0.073)
10 0.033 (0.073)
10 0.033 (0.073)
10 0.033 (0.073)
10 0.033 (0.073)
10 0.033 (0.073)
10 0.033 (0.073)
10 0.033 (0.073)

The sockets for CR-U interface relays have screw connection terminals and are suitable for snap-on mounting onto a DIN rail. Optional function modules for the CR-U range may only be plugged into compatible standard sockets.

-- Ordering details - Sockets and Accessories

Version

Type

Socket for 2 c/o and function module Socket for 3 c/o and function module Socket for 3 c/o Small socket for 2 c/o Small socket for 3 c/o Metal holder for socket

CR-U2S CR-U3S CR-U3E CR-U2SM CR-U3SM CR-UH

Order code
1SVR405670R0000 1SVR405660R0000 1SVR405660R0100 1SVR405670R1100 1SVR405660R1100 1SVR405669R0000

Pkg Weight (1 pc.)
qty kg 10 0.065
0.065 0.065 0.054 0.058 0.001

CR-U sockets Position of connection terminals: coil connection (A1-A2) on lower side of socket, contact connections (n/o and n/c contacts) on the lower and upper side of socket.

408

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Ordering details ­ CR-U function modules

CR-U...

2CDC 291 004 S0011

CR-U function modules are compatible with the CR-U2S and CR-U3S sockets only.

-- Diode - Reverse polarity protection / free-wheeling diode

Rated control supply voltage
6-220 V DC

Version A1+, A2-

Type CR-U 21

Order code

Pkg

qty

1SVR405661R0000

10

Weight (1 pc.) kg (lb)
0.007 (0.015)

-- Diode and LED - Reverse polarity protection / free-wheeling diode and LED to indicate energized coil

Rated control supply voltage
6-24 V DC 6-24 V DC 24-60 V DC 24-60 V DC 110 V DC 110 V DC

Version
red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2red, A1+, A2green, A1+, A2-

Type
CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV

Order code

Pkg

qty

1SVR405662R0000

10

1SVR405662R1000

1SVR405662R4000

1SVR405662R4100

1SVR405662R9000

1SVR405662R9100

Weight (1 pc.) kg (lb)
0.007 (0.015)

-- RC element - Spark quenching

Rated control supply voltage

Version

6-24 V AC/DC 24-60 V AC/DC 110 -230 V AC/DC

Type
CR-U 51B CR-U 51D CR-U 51C

Order code

Pkg

qty 1SVR405663R0000 10 1SVR405663R4000 1SVR405663R1000

Weight (1 pc.) kg (lb)
0.007 (0.015)

-- Diode and LED - LED to indicate energized coil

Rated control supply voltage

Version

Type

6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC

red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC: A1+, A2-

CR-U 61 CR-U 61V CR-U 61E CR-U 61EV CR-U 91 CR-U 91V

Order code

Pkg

qty 1SVR405664R0000 10 1SVR405664R1000 1SVR405664R4000 1SVR405664R4100 1SVR405664R0100 1SVR405664R1100

Weight (1 pc.) kg (lb)
0.007 (0.015)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

409

-- Pluggable interface relays and optocouplers Ordering details ­ CR-U function modules

CR-U... CR-U T

2CDC 291 032 F0005

2CDC 291 004 S0011

-- Varistor and LED - Overvoltage protection and LED to indicate energized coil

Rated control supply voltage

Version

6-24 V AC/DC 6-24 V AC/DC 24-60 V AC/DC 24-60 V AC/DC 110-230 V AC/DC 110-230 V AC/DC

red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2-

Type
CR-U 61C CR-U 61CV CR-U 61D CR-U 61DV CR-U 91C CR-U 91CV

Order code

Pkg

qty

1SVR405665R0000

10

1SVR405665R1000

1SVR405665R4000

1SVR405665R4100

1SVR405665R0100

1SVR405665R1100

Weight (1 pc.) kg (lb)
0.007 (0.015)

-- Varistor - Overvoltage protection

Rated control supply voltage

Version

24 V AC 115 V AC 230 V AC

-- Multi-function time module*

Rated control supply voltage

Version

24-240 V AC/DC

green LED

Type CR-U 71 CR-U 71A CR-U 81
Type CR-U T

* For more details, refer to the CR-U T datasheet.

Order code
1SVR405666R0000 1SVR405666R1000 1SVR405666R2000

Pkg Weight

(1 pc.)

qty

kg (lb)

10

0.007

(0.015)

Order code 1SVR405667R0000

Pkg Weight

(1 pc.)

qty

kg (lb)

10

0.014

(0.031)

410

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data - CR-S interface relays

Input circuit
CR-S005VDC1R(G) CR-S012VDC1R(G) CR-S024VDC1R(G) CR-S048VDC1R(G) CR-S060VDC1R(G)

Rated control supply voltage Us 5 V DC 12 V DC 24 V DC 48 V DC 60 V DC

Make voltage (at 23 °C)
3.75 V DC 9 V DC 18 V DC 36 V DC 45 V DC

Maximum voltage (at 55 °C) 7.5 V DC 18 V DC 36 V DC 72 V DC 90 V DC

Break voltage Rated power

0.25 V DC 0.6 V DC 1.2 V DC 2.4 V DC 3 V DC

170 mW 170 mW 170 mW 210 mW 210 mW

Coil resistance (at 23 °C) 147  848  3390  10600  16600 

Tolerance of coil resistance ± 10 % ± 10 % ± 15 % ± 15 % ± 15 %

Output circuits Output circuit(s) Kind of output Contact material Rated operational voltage Ue (IEC/EN 60947-1) Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current Ith Rated operational current (IEC/EN 60947-5-1)
AC rating (UL 508; NEMA ICS-5)
DC rating (UL 508; NEMA ICS-5)
Maximum making (inrush) current Minimum switching power Maximum switching (breaking) power Contact resistance Maximum operating frequency
Mechanical lifetime Electrical lifetime
Response time Release time Isolation data Rated insulation voltage Rated impulse withstand voltage Uimp
Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions Mounting Mounting position Degree of protection

11-12/14 1 c/o (SPDT) AgSnO2 or AgSnO2/Au 250 V AC 5 V at 100 mA (AgSnO2) / 5 V at 12 mA (AgSnO2/Au) 400 V AC / 250 V DC 10 mA at 10 V (AgSnO2) / 3 mA at 20 V (AgSnO2/Au) 5 A AC12 (resistive) 230 V 6 A AC15 (inductive) 230 V 1.5 A AC15 (inductive) 120 V 3 A DC12 (resistive) 24 V 6 A DC13 (inductive) 24 V 1 A DC13 (inductive) 120 V 0.22 A DC13 (inductive) 250 V 0.11 A utilization category (pilot duty) B300 (contact rating code designation) utilization category (pilot duty) R300 (contact rating code designation) 15 A, 240 V AC 100 mA/12 V (AgSnO2) / 50 mW (AgSnO2/Au) AC1 (resistive) 1500 VA, 250 V AC 100 m (at 1 A/ 6 V DC) rated load AC1 360 switching cycles/h without load 18000 switching cycles/h 1 x 107 switching cycles AC1 (resistive) (n/c) 3 x 104 switching cycles (at +85 °C) (n/o) 1 x 104 switching cycles (at +85 °C) 8 ms 4 ms
250 V AC between coil and contacts 4000 V 1 min
between open contacts 1000 V 1 min between coil and contacts 5.5 mm (0.217 in) between coil and contacts 8 mm (0.315 in)
III 2
see 'Dimensional drawings' on socket any RT II and RT III

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

411

-- Pluggable interface relays and optocouplers Technical data - CR-S interface relays and CR-S optocouplers

Electrical connection Connection Environmental data Ambient temperature range
Vibration resistance (10-150 Hz)
Shock resistance
Standards/directives Standards RoHS Directive

by socket
operation -40...+85 °C storage -40...+85 °C
n/o contact 10 Hz to 55 Hz 1 mm DA n/c contact 10 Hz to 55 Hz 1 mm DA n/o contact function 49 m/s2 / destructive 980 m/s2 n/c contact function 49 m/s2 / destructive 980 m/s2
IEC/EN 61810-1 2011/65/EU

-- Technical data - CR-S optocouplers

Input circuit Input resistance Rated control voltage Pull-in voltage Maximum input voltage Nominal input current Input power Typical switching-on time Typical switch-off time Output circuits Output circuit(s) Kind of output Rated operational voltage Maximum switching voltage Minimum switching current Maximum switching current continuously Leakage current at maximum switching voltage Voltage drop at rated current Isolation data Rated insulation voltage Insulation class Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions Weight Mounting Environmental data Ambient temperature
Standards / Directives Standards EMC Directive RoHS Directive
* The output circuit should not exceed 30 m.

CR-S024VDC1TRA 3400 Ohm 24 V DC* 15 V DC 30 V DC 7 mA 168 mW < 40 ms < 600 ms

CR-S024VDC1MOS
< 60 ms < 600 ms

11 (13+) - 14 Transistor 48 V DC 48 V DC 50 mA 100 mA <1 mA < 120 mV DC

11 (13+) - 14 MOS-FET 24 V DC 24 V DC 50 mA 2 A <1 mA < 120 mV DC

input/output 2.5 kV 2
input/output 14 mm input/output 14 mm
III 2

see 'Dimensional drawings' 3.5 g (0.007 lb) on socket

operation -30...+80 °C storage -40...+100 °C

IEC/EN 62314 2014/30/EN 2011/65/EN

CR-S024VDC1TRI
< 1/2 cycle < 1/2 cycle
11 (13+) - 14 Triac 240 V AC 275 V AC 22 mA 2 A < 1.5 mA < 1.6 V AC

412

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data - CR-S sockets

Input circuit

CR-S 6-24 V

CR-S 12-24 V CR-S 48-60 V CR-S 110-125 V

Rated control supply voltage Us Rated control supply voltage Us tolerance Typical current

6-24 V DC (0.8-1.2) Un 11-29 mA

12-24 V AC/DC* (0.8-1.1) Un 11-16 mA

48-60 V AC/DC 3.6-4.5 mA

110-125 V AC/DC 3.6 mA

Response time

8 ms

Release time

4 ms

Status device

green LED

Protective circuit

yes

Output circuits

Output circuit(s)

11-12/14

Number of poles

1

Rated voltage

250 V AC

Rated current

6 A

General data for CR-S with screw connection terminal

Dimensions

see 'Dimensional drawings'

Degree of protection (EN 60529)

Degree of protection (EN 60529) IP20 (terminals)

Temperature range

operation -40...+70 °C

-40...+55 °C

storage -40...+85 °C

Connection type

Screw

Maximum number of wires per connection terminal

2

Connecting capacity

rigid 2 x 0.5 - 1.5 mm² (2 x 20 - 16 AWG)

fine-strand

with wire end ferule 2 x 0.5 - 1 mm² (2 x 20 - 18 AWG)

Tightening torque

0.5 Nm (4.426 lb.in)

Stripping length

7 mm (0.28 in)

Minimum clamping force for fine-strand wire

with 0.2 mm² 10 N with 1.5 mm² 40 N

Mounting (IEC/EN 60715)

DIN rail

Material

socket PA6 +GF-V2

contacts CuZn36

contact surface 3  Ni/Sn

terminals CuZn40, 3  Ni

combi screw M3 Fe

General data for CR-S with spring connection terminal

Dimensions without holder (L x W x H)

see 'Dimensional drawings'

Degree of protection (EN 60529)

Degree of protection (EN 60529) IP20 (terminals)

Temperature range

operation -40...+70 °C

-40...+55 °C

storage -40...+85 °C

Connection type

Spring

Maximum number of wires per connection terminal

1

Connecting capacity

0.75 - 2.5 mm2 (20 - 14 AWG) rigid, fine-strand and with wire end ferrule

Stripping length

7 mm (0.28 in)

Mounting (IEC/EN 60715)

DIN rail

Material

socket PA6 +GF-V2

contacts CuZn36

contact surface 3  Ni/Sn

spring terminals SUS301

Isolation data

Isolation between coil and contacts

5000 V AC

Resistance to shock coil to contact

1000 M

Clearance and creepage distance

IEC/EN 61984

Standards / Directives

Standard

IEC/EN 61984

Low Voltage Directive

2014/35/EU

RoHS Directive

2011/65/EU

CR-S 220-240 V 220-240 V AC/DC
3.6 mA

* In combination with optocouplers, only DC supply is allowed

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

413

-- Pluggable interface relays and optocouplers Technical data - CR-S jumper bars

Rated operational voltage / current

CR-SJB20-BLUE

Rated operational voltage

250 V AC

Rated operational current

36 A

Electrical connection

Jumper bar cross section

123.2 mm (4.850 in)

Step distance

6.3 mm (0.248 in)

Rail length

with isolation 16.7 mm (0.657 in)

without isolation 6.7 mm (0.264 in)

Stripping length of a connection wire that is used in combination with a jumper bar

7 mm (0.276 in)

Environmental data

Ambient temperature range

operation -40 ... +70 °C

General data

Material of rail

Cu

Number of pins

20

Flammability

V0

CR-SJB20-RED

CR-SJB20-BLACK

414

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data ­ CR-P, CR-M, CR-U

-- Input circuit - coil data

CR-P range

Rated control supply voltage US

Rated frequency

Make voltage Maximum

(at 20 °C)

voltage

(at 55 °C)

Break voltage

DC coils AC coils

12 V DC 24 V DC 48 V DC 110 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC

CR-P optocouplers range
Input circuit Input resistance Rated control voltage Pull-in voltage Maximum input voltage Nominal input current
Input power Typical switching-on time Typical switch-off time

50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz

8.4 V DC 16.8 V DC 33.6 V DC 77 V DC 19.2 V AC 38.4 V AC 88 V AC 96 V AC 184 V AC

30.6 V DC 61.2 V DC 122.4 V DC 280 V DC 28.8 V AC 57.6 V AC 132 V AC 144 V AC 276 V AC

 0.1 US  0.1 US  0.1 US  0.1 US  0.15 US  0.15 US  0.15 US  0.15 US  0.15 US

CR-P024MOS1 2200  24 V DC 10 V DC 32 V DC 10 mA
260 mW 50 ms 250 ms

CR-M range

Rated control supply voltage US

Rated frequency

Make voltage Maximum

(at 20 °C)

voltage

(at 55 °C)

Break voltage

DC coils AC coils

12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC

50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz

9.6 V DC 19.2 DC 38.4 V DC 48 V DC 88 V DC 100 V DC 176 V DC 19.2 V AC 38.4 V AC 48 V AC 88 V AC 96 V AC 184 V AC

13.2 V DC 26.4 V DC 52.8 V DC 66 V DC 121 V DC 137.5 V DC 242 V DC 26.4 V AC 52.8 V AC 66 V AC 121 V AC 132 V AC 253 V AC

 0.1 US  0.1 US  0.1 US  0.1 US  0.1 US  0.1 US  0.1 US  0.2 US  0.2 US  0.2 US  0.2 US  0.2 US  0.2 US

Rated power

Coil resistance (at 20 °C)

Tolerance of coil resistance

0.4-0.48 W 0.4-0.48 W 0.4-0.48 W 0.4-0.48 W 0.75 VA 0.75 VA 0.75 VA 0.75 VA 0.75 VA

360  1440  5700  25200  400  1550  8900  10200  38500 

± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10%

CR-P024TRI1 1950  24 V DC 10 V DC 32 V DC 12 mA
295 mW < 1/2 cycle < 1/2 cycle

Rated power

Coil resistance (at 20 °C)

Tolerance of coil resistance

0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 1.6 VA 1.6 VA 1.6 VA 1.6 VA 1.6 VA 1.6 VA

160  640  2600  4000  13600  16000  54000  158  640  930  3450  3770  16100 

± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10%

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

415

-- Pluggable interface relays and optocouplers Technical data ­ CR-P, CR-M, CR-U

CR-U range

Rated control supply voltage US

Rated frequency

Make voltage Maximum

(at 20 °C)

voltage

(at 55 °C)

Break voltage

DC coils AC coils

12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 24 V AC
48 V AC
60 V AC
110 V AC
120 V AC
230 V AC

50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz

9.6 V DC 19.2 V DC 38.4 V DC 88.0 V DC 100 V DC 176.0 V DC 19.2 V AC
38.4 V AC
48.0 V AC
88.0 V AC
96.0 V AC
184.0 V AC

13.2 V DC 26.4 V DC 52.8 V DC 121.0 V DC 137.5 V DC 242.0 V DC 26.4 V AC
52.8 V AC
66.0 V AC
121.0 V AC
132.0 V AC
253.0 V AC

 0.1 US  0.1 US  0.1 US  0.1 US  0.1 US  0.1 US  0.15 US
 0.15 US
 0.15 US
 0.15 US
 0.15 US
 0.15 US

Rated power

Coil resistance (at 20 °C)

Tolerance of coil resistance

1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz)

110  430  1750  9200  11000  37000  75 
305 
475 
1700 
1910 
7080 

± 10 % ± 10 % ± 10 % ±10 % ± 10 % ± 10 % ± 10 %
± 10 %
± 10 %
± 10 %
± 10 %
± 10 %

416

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data ­ CR-P, CR-M, CR-U

Type

CR-P...1

CR-P...2

CR-M...2

CR-M...3

CR-M...4

CR-U...2

CR-U...3

Output circuit(s)

11-12/14

11-12/14 21-22/24

11-12/14 21-22/24

11-12/14 21-22/24 31-32/34

11-12/14 21-22/24 31-32/34 41-42/44

11-12/14 31-32/34

11-12/14 21-22/24 31-32/34

Kind of output

Relay, 1 c/o Relay, 2 c/o Relay, 2 c/o Relay, 3 c/o Relay, 4 c/o Relay, 2 c/o Relay, 3 c/o

Contact material

AgNi

AgNi AgNi/Au 5 µm

AgNi

AgNi

AgNi AgNi/Au 5 µm

AgNi

Rated operational voltage Ue (VDE 0110, IEC 60947-1)

250 V

Minimum switching voltage

5 V

10 V (AgNi); 5 V (AgNi/Au)

10 V

Maximum switching voltage

DC 300 V DC

250 V DC

AC 440 V AC

250 V AC

440 V AC

Minimum switching current

5 mA (AgNi), 2 mA (AgNi/Au)

5 mA (AgNi) 5 mA (AgNi) 2 mA (AgNi/Au)

5 mA

Rated free air thermal current Ith

16 A

Rated

AC-12 (resistive) 230 V 16 A

operational current (IEC 60947-5-1)

AC-15 (inductive) 230 V 1.5 A AC-15 (inductive) 120 V 3 A
DC-12 (resistive) 24 V 16 A

8 A 8 A 1.5 A
8 A

12 A 12 A 1.5 A
12 A

10 A 10 A 1.5 A
10 A

6 A 6 A 1 A 1.5 A 6 A

10 A 10 A 1.5 A 3 A 10 A

DC-13 (inductive) 24 V 2.5 A

2 A

2.5 A

2.5 A

2 A

2 A

DC-13 (inductive) 120 V 0.22 A

DC-13 (inductive) 250 V 0.1 A

AC rating (UL 508)

utilization category (pilot B300 duty) (contact rating code
designation)

B300

B300

max. rated operational 300 V AC voltage

300 V AC

300 V AC

max. continuous 5 A thermal current at utilization category

5 A

5 A

2.5 A

5 A

max. making / breaking 3600 / 360 VA apparent
power at utilization category

3600 / 360 VA

1800 / 180 VA

3600/360 VA

utilization category 16 A, (resistive) 250 V AC
(CSA22.2 No.14....)

8 A, 250 V AC 10 A,

6 A, 250 V AC 5 A, 250 V AC 10 A, 250 V AC

250 V AC

10 A,

10 A,

(resistive + single-phase)

12 A,150 V AC 150 V AC

150 V AC

DC rating * (UL 508; NEMA ICS-5)

utilization category R300 (pilot duty)
(contact rating code designation)

max. rated operational 300 V DC voltage

max. continuous 1 A thermal current at utilization category

max. making / breaking 28 VA apparent
power at utilization category

utilization category (resistive)
(CSA22.2 No.14....)

10 A, 24 V DC -

10 A, 28 V DC

Maximum making (inrush) current

30 A

15 A

24 A

20 A

12 A

20 A

Minimum switching power

0.3 W (AgNi), 0.05 W (AgNi/Au)

0.3 W (AgNi), 0.1 W (AgNi/Au)

0.3 W

Maximum switching (breaking)

AC1 4000 VA

power

(resistive)

2000 VA

3000 VA

2500 VA

1500 VA

2500 VA

Contact resistance

 100 m

Maximum operating frequency rated load 600 switching cycles/h AC-1

1200 switching cycles/h

without 72000 switching cycles/h load

18000 switching cycles/h

12000 switching cycles/h

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

417

-- Pluggable interface relays and optocouplers Technical data ­ CR-P, CR-M, CR-U

Type Mechanical lifetime Electrical lifetime

CR-P...1

CR-P...2

> 3 x 107 switching cycles

electrical > 0.7 x 105 AC1 switching
(resistive) cycles (16 A, 250 V)

> 105 switching cycles (8 A, 250 V)

CR-M...2

CR-M...3

> 2 x 107 switching cycles

> 105 switching cycles

(12 A, 250 V) (10 A, 250 V)

CR-M...4 (6 A, 250 V)

cos  see reduction factor F

Response time

typ. 7 ms

Release time

typ. 3 ms

Isolation data

Rated insulation voltage

400 V AC

Insulation class (In accordance to VDE 0110b)

C250 / B400

Rated impulse withstand voltage Uimp

between coil and contacts 5 kV between open contacts 1 kV between c/o (SPDT) contacts

2.5 kV

Clearance between coil and contacts

 10 mm

Creepage distance between coil and contacts

 10 mm

Overvoltage category

III

Pollution degree

3

General data

Dimensions

see 'Dimensional drawings'

Mounting

on socket (see accessories)

Mounting position

any

Degree of protection

IP 67

Electrical connection

Connection

by socket

Environmental data

Ambient temperature range

operation DC: -40...+85 °; AC: -40...+70 °C

storage -40 ... +85 °C

Vibration resistance 10-150 Hz

n/o contact 10 g

n/c contact 10 g

5 g

Shock resistance

n/o contact 30 g

20 g

n/c contact 30 g

20 g

Standards / Directives

Standards

IEC/EN 61810-1

Low Voltage Directive

-

RoHS Directive

2011/65/EU

typ. 13 ms (DC), 10 ms (AC) typ. 3 ms (DC), 8 ms (AC)

250 V AC C250 / B250
2.5 kV 1.5 kV 2.5 kV
 2.5 mm  4 mm
III 3

 2 kV
 1.6 mm  3.2 mm
II 2

IP 40
DC: -40...+70 °; AC: -40...+55 °C
5 g 5 g 10 g 5 g
2014/35/EU

CR-U...2

CR-U...3

> 105 switching cycles (12 A, 250 V)

typ. 18 ms (DC), 12 ms (AC) typ. 7 ms (DC), 10 ms (AC)
C250

2 kV
 3 mm  4.2 mm
III 3

5 g 5 g 10 g 10 g

* These ratings are based on different type tests which are not covered by the cULus or CSA approvals.

418

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data ­ CR-P optocouplers

Output circuits Output circuit(s) Kind of output Rated operational voltage Maximum switching voltage Minimum switching current Maximum switching current continuously Leakage current at maximum switching voltage Voltage drop at rated current Isolation data Rated insulation voltage Insulation class Clearance Creepage distance Overvoltage category Pollution degree General data Dimensions Weight Mounting Environmental data Ambient temperature
Standards / Directives Standards EMC Directive RoHS Directive

CR-P024MOS1 11 (13+) - 14 MOS-FET 24 V DC 35 V DC 1 mA 5 A 10 uA 300 mV
input/output 2.5 kV 2
input/output 19 mm input/output 19 mm
III 2
see 'Dimensional drawings' 11 g (0.618 lbs) on socket
operational -20...+80 °C
storage -40...+100 °C
IEC/EN 62314 2014/30/EU 2011/65/EU

CR-P024TRI1 11 (13+) - 14 Triac 240 V AC 275 V AC 50 mA 3,5 A 1 mA 1.1 V
2.5 kV 2 19 mm 19 mm III 2
11 g (0.618 lbs) on socket
-20...+80 °C
-40...+100 °C
IEC/EN 62314 2014/30/EU 2011/65/EU

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

419

-- Pluggable interface relays and optocouplers Technical data - CR-P and CR-M sockets

Output circuits

CR-PLS

CR-PLSx

CR-PSS

CR-PLC

CR-MxLS

CR-MxSS

CR-MxSF

CR-MxLC

Output circuit(s)

11-12/14, 21-22/24

11-12/14, 21-22/24, ...

Number of poles

2

2, 3 or 4

2 or 4

Rated voltage

250 V AC/DC 300 V AC/DC 250 V AC/DC

250 V AC/DC

300 V AC/DC

Rated current

2 x 10 A1)

2 x 12 A1)

2 x 10 A1)

7 A

10 A

General data

Dimensions without holder and module (L x W x H)

76 x 15.8 x 62 78.5 x 15.5 x 76 x 15.8 x

mm

61 mm

42.8 mm

(2.992 x

(3.011 x 0.610 (2.992 x

0.622 x

x 2.402 in) 0.622 x

2.441 in)

1.685 in)

97.5 x 16.3 x 45.2 mm (3.839 x 0.642 x 1.780 in)

75 x 27.2 x 60.8 mm (2.952 x 1.071 x 2.394 in)

75.2 x 27.2 x 42.6 mm (2.961 x 1.071 x 1.677 in)

66.7 x 30.3 x 95 x 31 x 42.5

29 mm (2.626 mm

x 1.193 x

(3.74 x 1.22 x

1.142 in)

1.67 in)

Degree of protection

terminals IP 20 B (EN 60529)

Temperature range

operation -40...+70 °C storage -40...+70 °C

-40...+85 °C -40...+85 °C

-40...+70 °C -40...+70 °C

-40...+70 °C -40...+70 °C

-25...+85 °C

Connection type

screw connection

spring

screw connection

connection

fork type screw

spring connection

Maximum number

2

of wires per

connecting terminal

2 (one per 2 connection point)

-

2 (one per

connection

point)

Connecting capacity

rigid 2 x 0.5 - 2.5 mm2 (2 x 20 - 14 AWG) fine-strand

2 x 0.2 - 1.5 mm2 (2 x 24 - 16 AWG)

2 x 0.5 - 2.5 mm2 (2 x 20 - 14 AWG)

2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)

with wire end 2 x ferrule 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)

2 x 1.5 mm2 (2 x 16 AWG)

2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)

2 x 1.5 mm2 (2 x 16 AWG)

2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)

2 x 1.5 mm2 (2 x 16 AWG)

Stripping length

7 mm (0.28 in)

11 mm (0.43 in)

7 mm (0.28 in)

10 mm (0.39 in)

Tightening torque

0.6 Nm

0.8 Nm

0.6 Nm

0.6 Nm (5.31 lb.in)

Maximum

with 0,2 mm2 -

-

-

10 N

-

-

-

10 N

clamping

with 1,5 mm2 -

-

-

40 N

-

-

-

40 N

force

with wire end -

-

-

-

> 40 N

ferrule

Mounting

DIN rail (IEC/EN 60715)

Material

socket PA 6+GF - V2

PA 6+GF - V2

contacts CuZn33

CuZn33

contact surface 5  Ni

5  tinned 5  Ni

5  Ni

6  Ni

5  tinned

terminals 8  Ni

8  galvanized

8  Ni

XCrNi Steel 8  Ni

CCSC

combi screw M3 8.8 Steel, 5 Ni

-

8.8 Steel, 5 Ni

-

Isolation data

Insulation voltage

> 5 kV

> 3 kV

> 5 kV

> 3 kV

> 4 kV

Isolation between coil and contacts

IEC/EN 61984

Clearance and creepage distance

IEC/EN 61984

Standards / Directives

Standards

IEC/EN 61984

Low Voltage Directive

2014/35/EU

RoHS Directive

2011/65/EU

1) Loads >10 A ( >12 A for CR-PLSx) require jumpering of terminal 11 with 21, 12 with 22, and 14 with 24

420

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data - CR-P and CR-M jumper bars

Rated operational voltage / Rated current

CR-PJ

Rated operational voltage (VDE 0660 / part 500)

400 V

Rated current (VDE 0660 / part 500)

25 A

Electrical connection

Bus bar diameter

6 mm² (0.0093 in²)

Step distance

15.5 mm (0.610 in)

Rail length

with isolation 150 mm (5.906 in)

without isolation 141.5 mm (5.571 in)

Stripping length of a connection wire that is used in combination with a jumper bar

6 mm (0.236 in)

Environmental data

Ambient temperature range

operation -40... +55 °C

Isolation data

Rated impulse withstand voltage Uimp (VDE 0660 / part 500)

4 kV

Overvoltage category (IEC/EN 60664)

III

Polution degree (IEC/EN 60664)

2

General data

Material of rail

E-Cu-F25

Type of rail

pin type

Number of pins

10

Number of phases

1

Color of insulating material

RAL 7035

Flammability (UL 94)

V0

CR-MJ
27.2 mm (1.071 in) 255 mm (10.039 in) 245 mm (9.646 in)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

421

-- Pluggable interface relays and optocouplers Technical data - CR-P and CR-M function modules

CR-P/M 22 Type Version Function Control supply voltage Component data Polarized Material CR-P/M 42 Type Version Function Control supply voltage Component data
Polarized Material CR-P/M 52 Type Version Function Control supply voltage Component data
Polarized Material CR-P/M 62 Type
Version Control supply voltage Component data
Polarized Material CR-P/M 72, 82 Type Version Function Control supply voltage Component data Polarized Material CR-P/M 92 Type Version Control supply voltage Component data
Polarized Material Standards / Directives Standards Low Voltage Directive RoHS Directive

CR-P/M 22 Diode Reverse polarity protection 6-220 V DC diode 1 A, 1000 V yes (A1+, A2-) enclosure / base PA6 + GF V2

CR-P/M 42

CR-P/M 42V CR-P/M 42B CR-P/M 42BV CR-P/M 42C CR-P/M 42CV

Diode and LED

Reverse polarity protection, applied supply voltage indicated via LED

6-24 V DC

24-60 V DC

110 V DC

diode 1 A, 1000 V

LED red

green

red

green

red

green

resistance 3 k, 0.25 W

15 k, 0.25 W

200 k, 0.25 W

yes (A1+, A2-)

enclosure / base PA6 + GF V2

CR-P/M 52B RC element Arc elimination 6-24 V AC/DC capacitor 0.1 µF, 63 V DC resistance 10 , 0.25 W no enclosure / base PA6 + GF V2

CR-P/M 52D
24-60 V AC/DC 0.1 µF, 100 V DC 47 , 0.25 W

CR-P/M 52C
110-230 V AC/DC 0.082 µF, 400 V DC 100 , 0.25 W

CR-P/M 62

CR-P/M 62V

CR-P/M 62E

CR-P/M 62EV

Diode and LED

6-24 V AC/DC

24-60 V AC/DC

diode 1 A, 1000 V

LED red

green

red

green

varistor 25 V AC

75 V AC

resistance 3 k, 0.25 W

15 k, 0.25 W

AC: no, DC: yes (A1+, A2-)

enclosure / base PA6 + GF V2

CR-P/M 62C

CR-P/M 62CV

Varistor and LED

6-24 V AC/DC

red

green

25 V AC

3 k, 0.25 W

CR-P/M 62D

CR-P/M 62DV

24-60 V AC/DC

red

green

75 V AC

15 k, 0.25 W

CR-P/M 72 Varistor Overvoltage protection 24 V AC varistor 25 V AC no enclosure / base PA6 + GF V2

CR-P/M 72A
115 V AC 115 V AC

CR-P/M 82
230 V AC 275 V AC

CR-P/M 92

CR-P/M 92V

Diode and LED

110-230 V AC / 110 V DC

diode 1 A, 1000 V

LED red

green

varistor 275 V AC

resistance 120 k, 0.25 W

AC: no, DC: yes (A1+, A2-)

enclosure / base PA6 + GF V2

CR-P/M 92C Varistor and LED

CR-P/M 92CV

red

green

IEC/EN 61984 2014/35/EU 2011/65/EU

422

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical data - CR-U sockets and function modules

Output circuits

CR-U2S

CR-U3S

Output circuit(s)

11-12/14, 21-22/24,...

Number of poles

2

3

Rated voltage

250 V AC

Rated current

10 A

General data

Dimensions

see 'Dimensional drawings'

Degree of protection

terminals IP 20 B (EN 60529)

Temperature range

operation -40...+70 °C

storage -40...+70 °C

Connecting capacity

rigid 2 x 2 x 0,5 - 2,5 mm2 (2 x 20 - 14 AWG) fine-strand

with wire end ferrule 2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)

Stripping length

7 mm (0.28 in)

Tightening torque

0.6 Nm

Mounting

DIN rail (IEC/EN 60715)

Material

socket PA 6+GF - V2

contacts CuZn33

contact surface 6  Ni

terminals 8  Ni

combi screw M3 8.8 steel, 5 Ni

Isolation data

Insulation voltage

> 2 kV

Isolation between coil and contacts IEC/EN 61984

Clearance and creepage distance IEC/EN 61984

Standards/Directives

Standards

IEC/EN 61984

Low Voltage Directive

2014/35/EU

RoHS Directive

2011/65/EU

CR-U3E 300 V AC

CR-UxSM
2 or 3 250 V

-40...+85 °C -40...+85 °C
2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)
0.8 Nm

-40...+70 °C -40...+70 °C
2 x 0.5 - 1.5 mm2 (2 x 20 - 16 AWG)
0.6 Nm

8  galvanized

3  Ni 10  Ni Steel, 8  Ni

-- Technical data - CR-U function modules

CR-U 21 Type Version Function Control supply voltage Component data Polarized Material CR-U 41 Type Version Function
Control supply voltage Component data
Polarized Material

CR-U 21 Diode Reverse polarity protection and elimination of the converse current 6-220 V DC Diode 1 A, 1000 V yes (A1+, A2-) Enclosure / Base PA6 + GF V2

CR-U 41

CR-U 41V

CR-U 41B

CR-U 41BV

CR-U 41C

CR-U 41CV

Diode and LED

Reverse polarity protection and elimination of the converse current. LED to indicate the energization of coil

6-24 V DC

24-60 VDC

110 V DC

Diode 1 A, 1000 V

LED red

green

red

green

red

green

Resistance 3 k, 0.25 W

15 k, 0.25 W

200 k, 0.25 W

yes (A1+, A2-)

Enclosure / Base PA6 + GF V2

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

423

-- Pluggable interface relays and optocouplers Technical data - CR-U function modules

CR-U 51 Type Version Function Control supply voltage Component data
Polarized Material CR-U 61 Type Version Function
Control supply voltage Component data
Polarized Material CR-U 71, 81 Type Version Function Control supply voltage Component data Polarized Material CR-U 91 Type Version Function
Control supply voltage Component data
Polarized Material Standards / Directives Standards Low Voltage Directive RoHS Directive

CR-U 51B RC element Arc elimination 6-24 V AC/DC Capacitor 0.1 µF, 63 V DC Resistance 10 , 0.25 W no Enclosure / Base PA6 + GF V2

CR-U 51D
24-60 V AC/DC 0.1 µF, 100 V DC 47 , 0.25 W

CR-U 51C
110-230 V AC/DC 0.082 µF, 400 V DC 100 , 0.25 W

CR-U 61 CR-U 61V CR-U 61E CR-U 61EV CR-U 61C CR-U 61CV CR-U 61D CR-U61DV

Diode and LED

Varistor and LED

Reverse polarity protection and elimination of the converse current. LED to indicate the energization of coil.

Overvoltage protection, LED to indicate the energized of coil

6-24 V AC/DC

24-60 V AC/DC

6-24 V AC/DC

24-60 V AC/DC

Diode 1 A, 1000 V

LED red

green

red

green

red

green

red

green

Resistance 3 k, 0.25 W

15 k, 0.25 W

3 k, 0.25 W

15 k, 0.25 W

AC: no, DC: yes (A1+, A2-)

Enclosure / Base PA6 + GF V2

CR-U 71 Varistor Overvoltage protection 24 V AC Varistor 25 V AC no Enclosure / Base PA6 + GF V2

CR-U 71A
115 V AC 115 V AC

CR-U 81
230 V AC 275 V AC

CR-U 91

CR-U 91V

Diode and LED

Reverse polarity protection and elimination of the converse current. LED to indicate the energization of coil.

110-230 V AC / 110 V DC

Diode 1 A, 1000 V

LED red

green

Resistance 120 k, 0.25 W

AC: no, DC: yes (A1+, A2-)

Enclosure / Base PA6 + GF V2

CR-U 91C

CR-U 91CV

Varistor and LED

Overvoltage protection, LED to indicate the energized of coil

red

green

IEC/EN 61984 2014/35/EU 2011/65/EU

424

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical diagrams

-- Connection diagrams

2CDC 292 015 F0005

2CDC 292 014 F0005

2CDC 292 013 F0005

CR-P/M 22

CR-P/M 42, CR-P/M 42B, CR-P/M 42C, CR-P/M 42V, CR-P/M 42BV, CR-P/M 42CV

CR-P/M 52B, CR-P/M 52C CR-P/M 52D,

2CDC 292 018 F0005

2CDC 292 017 F0005

2CDC 292 016 F0005

CR-P/M 62, CR-P/M 62E, CR-P/M 92, CR-P/M 62V, CR-P/M 62EV, CR-P/M 92V

CR-P/M 62C, CR-P/M 62D, CR-P/M 92C, CR-P/M 62CV, CR-P/M 62DV, CR-P/M 92CV

CR-P/M 72, CR-P/M 82 CR-P/M 72A,

2CDC 292 014 F0005

2CDC 292 013 F0005

CR-U 21

CR-U 41, CR-U 41B, CR-U 41C, CR-U 41V, CR-U 41BV, CR-U 41CV

CR-U 51B, CR-U 51C CR-U 51D

2CDC 292 015 F0005

2CDC 292 018 F0005

2CDC 292 017 F0005

2CDC 292 016 F0005

CR-U 61, CR-U 61E, CR-U 91, CR-U 61V, CR-U 61EV, CR-U 91V

CR-U 61C, CR-U 61CV, CR-U 61D, CR-U 61DV, CR-U 91C, CR-U 91CV

CR-U 71, CR-U 71A , CR-U 81

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

425

-- Pluggable interface relays and optocouplers Technical diagrams

-- Connection diagrams

2CDC 292 024 F0004

2CDC 292 011 F0004 2CDC 292 016 F0004

2CDC 292 001 F0004

CR-P with 1 c/o contact

CR-M with 2 c/o contacts

CR-M with 3 c/o contacts

CR-U with 2 c/o contacts

2CDC 292 030 F0004

2CDC 292 001 F0014

2CDC 292 020 F0004

2CDC 292 008 F0004

CR-P with 2 c/o contacts
A1 +
A2 -
CR-S optocoupler with Transistor
A1 +
A2 -
CR-S optocoupler with MOSFET
A1 +
A2 -
CR-S optocoupler with Triac

CR-M with 4 c/o contacts

CR-S
+ 11(13+)
-
14

2CDC 292 001 F0016

+ 11(13+)
-
14

2CDC 292 002 F0016

2CDC 292 001 F0016

V AC 11(13+)
V AC 14

CR-U with 3 c/o contacts

426

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical diagrams

-- CR-P: Operating range of coils

U/Us

U/Us

2CDC 292 038 F0204

2CDC 292 037 F0204

Ambient temperature [°C] Operating range of DC coil

Ambient temperature [°C] Operating range of AC coil

A

unloaded contacts, coil temperature = ambient temperature

B

continued with Ith (16 A at CR-P ... 1 and 8 A at CR-P ... 2) loaded contacts coil heated with 1,1 x Us

1

at unloaded contacts

2

at 50 % rated load

3

at rated load

-- Electrical connection
22 12 21 11 24 14
21 11
22 2412 14

21 11 24 14 22 12
21 11
22 2412 14

A2 A1

A2 A1

CR-PLS

A1-A2 11-12/14, 21-22/24

Supply voltage Relay outputs Relay outputs

A2 A1
A2 A1
CR-PLSx, CR-PLC

21 11 24 14
21 11
22 2412 14
A2 A1
A2 A1 22 12
CR-PSS

2CDC 292 063 F0004 2CDC 292 083 F0004 2CDC 292 009 F0007

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

427

-- Pluggable interface relays and optocouplers Technical diagrams

-- Mounting and removal of sockets

2CDC 292 061 F0004 2CDC 292 062 F0004

2CDC 292 075 F0004 2CDC 292 074 F0004 2CDC 292 073 F0004

2CDC 292 009 F0004 2CDC 292 008 F0004

Mounting

-- Electrical connection

41

11

44

14

42

12

41

11

42 44 12 14

A2 A1

A2 A2

A1

CR-M2LS

41

11

44

14

42

12

41

11

42 44 12 14

A2 A1

A2

A1

CR-M2LC

Removal

31 21 11 34 24 14 32 22 12
31 21 11
32 34 22 24 12 14

A2 A1

A2 A2

A1

CR-M3LS

41 31 21 11 44 34 24 14 42 32 22 12
41 31 21 11
42 4432 34 22 2412 14

A2 A1

A2

A1

CR-M4LC

41 31 21 11 44 34 24 14 42 32 22 12
41 31 21 11
42 4432 34 22 2412 14

A2 A1

A2 A2

A1

CR-M4LS

428

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical diagrams

-- Electrical connection

44

14

42

12

41

11

42 44 12 14

34 24 14 32 22 12

31

21

11

32 34 22 24 12 14

44 34 24 14 42 32 22 12
41 31 21 11
42 4432 34 22 2412 14

A2 A1

A2

A1

41

11

CR-M2SS, CR-M2SF

A1-A2 11-12/14, 41-42/44

Supply voltage Relay outputs Relay outputs

2CDC 292 070 F0004 2CDC 292 069 F0004 2CDC 292 068 F0004

A2 A1

A2

A1

31 21 11

CR-M3SS

A1-A2 11-12/14, 21-22/24, 31-32/34

Supply voltage Relay outputs Relay outputs Relay outputs

A2 A1

A2

A1

41 31 21 11

CR-M4SS, CR-M4SF

A1-A2 11-12/14, 21-22/24 31-32/34 41-42/44

Supply voltage Relay outputs Relay outputs Relay outputs Relay outputs

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

429

-- Pluggable interface relays and optocouplers Technical diagrams

-- Technical diagrams CR-S interface relays

Operations (*1000 ops)

DC current (A)

10 5

2

100

50

1
0.5 10
5 0.2

2CDC 292 012 F0214

0.1 10

20

50 100

200

DC voltage (V)

Max. DC load breaking capacity

012

34

5

6

78

Contact current (A)

Endurance curve

-- Load limit curves CR-P, CR-M and CR-U - Electrical lifetime at resistive AC load

2CDC 292 013 F0214

22CCDDC2C922090290F00290F40204 Switching cycles

22CCDDC2C922902030F00230F40204 Switching cycles

Switching cycles

22CCDDC2C92209227F002270F40204

Switching power [kVA] CR-P with 1 c/o contact

Switching power [kVA] CR-P with 2 c/o contacts

Switching power [kVA] CR-U with 2 and 3 c/o contacts

22CCDDC2C92209128F001280F40204 Switching cycles

22CCDDC2C92209123F001230F40204 Switching cycles

Switching cycles

22CCDDC2C92290220F02220F40204

Switching power [kVA] CR-M with 2 c/o contacts

Switching power [kVA] CR-M with 3 c/o contacts

Switching power [kVA] CR-M with 4 c/o contacts

22CCDDCC2922902280F20820F40204

430

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical diagrams

-- Load limit curves CR-P, CR-M and CR-U - Maximum switching power at resistive DC load
1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms

DC current [A]

DC current [A]

DC current [A]

22CCDDC2C922901200F10200F40204

22CCDDC2C922902050F00520F40204

DC voltage [V] CR-P with 1 c/o contact

DC voltage [V] CR-P with 2 c/o contacts

DC voltage [V]
CR-U with 2 and 3 c/o contacts

DC current [A]

DC current [A]

DC current [A]

1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms

22CCDDC2C92290125F001250F40204

DC voltage [V]

DC voltage [V]

CR-M with 2 c/o contacts

CR-M with 3 c/o contacts

-- Reduction factor CR-P, CR-M and CR-U ­ F at inductive AC load

22CCDDCC2922902190F1092F004204

1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms
1 2
DC voltage [V] CR-M with 4 c/o contacts

2CDC292023F0204

Reduction factor

2CCDDC2C922902040F00420F40204 Reduction factor

Reduction factor

22CCDDC2C92290290F20290F40204

22CCDDC2C922901240F10240F40204

CR-P

Power factor

CR-M

Power factor

CR-U

Power factor

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

431

-- Pluggable interface relays and optocouplers Technical diagrams

-- Derating curves

120 100
80 60 40 20

-20

0

20

40

60

80

100

120

Stand alone installed optocoupler Side-by-side installed optocouplers

Ambient temperature [°C]

Derating curve Transistor output CR-S

2CDC 292 005 F0016

Current [A]

4 3 2 1

0

10

20

30

40

50

60

70

80

90

Stand alone installed optocoupler Side-by-side installed optocouplers

Ambient temperature [°C]

Derating curve MOS-FET output CR-S

2CDC 292 006 F0016

Current [A]

2 1.5 1.0 0.5

-20

0

20

40

60

Stand alone installed optocoupler Side-by-side installed optocouplers

80

100

Ambient temperature [°C]

Derating curve Triac output CR-S

Current [mA]

2CDC 292 007 F0016

22CCDDC2C922902010F00101F70017
Current (A)
22CCDDCC2922902020F00201F70017

Current (A)

6

5

4

3

1 = Stand alone installed

2 = Side by side installed

2

1

0 -20

0

20

40

60

80

100

Ambient temperature (°C)

MOS-FET output CR-P

4

3,5

3

2,5

1 = Stand alone installed

2 = Side by side installed
2

1,5

1

0,5

0 -20

0

20

40

60

80

100

Ambient temperature (°C)

Triac output CR-P

15 0.591
2CDC292004F0016

432

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical diagrams

-- Dimensional drawings in mm and inches
28 1.102

28 1.102

5 0.197

3.8 0.150

15 0.591

2CDC292052F0013

3.5 0.138

0.5 0.020

0.9 0.035

0.5 0.020

16.38 0.645

3.78 0.149

CR-S relay

1 0.039 5.04 0.198

5 0.197

76.6 3.016

6.2 0.244
12 11 14
3.5 0.138

94.7 3.728

35.4 1.394

2CDC292053F0013

12-24 V  A1 A2
73.2 2.882
CR-S socket - spring connection

1 0.039 1.8 0.071 CR-S optocoupler

0.8 0.031

1.3 0.051

70.9 2.791 55.4 2.181

35.8 1.409

12

11

14

44.2 1.74 28 1.102 35.4 1.394
2CDC292054F0013

88.3 3.476 69.4 2.732 52 2.047

CR-S socket - screw connection

16.7 0.657

0.8 0.031 6.7 0.264

2.8 0.110

A1 A2
6.3 0.272

20.6 0.811 40.2 1.583 59.8 2.354 71.1 2.799
2CDC292003F0014 2CDC 292 002 F0014

35.7 1.406 92.7 3.650
CR-S separator

123.2 4.850

16.7 0.657

0.8 0.031

2.8 0.110

6.3 0.248

6.7 0.264

CR-SJB20 - blue, CR-SJB20 - red, CR-SJB20 - black jumper bar

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

433

-- Pluggable interface relays and optocouplers Technical diagrams

-- Dimensional drawings in mm and inches

12.7 0.5 7.5 0.296

29 1.412

29 1.412

5 0.197

15 0.591

5 0.197

15 0.591

15.7 0.618

2.5 0.098
2.5 0.098

12.7 0.5 7.5 0.296

2CDC292003F0017

2CDC292002F0004

15.7 0.618 3.9 0.154

3.9 0.154

2CDC292033F0004

CR-P relay

Marker 15.8 0.622

7.5 0.295

22

NC

12

21

COM

11

24

NO

14

62 2.441 51.2 2.016 29 1.142

Relay

10 0.394 20 0.787
76 2.992

A2 COIL A1

CR-PLS - screw connection

Marker

21

COM

11

24

NO

14

42.8 1.685

10 0.394 20 0.787 76 2.992

A2 COIL

A1

22

NC

12

24 0.945 15.8 0.622 CR-PSS - screw connection

12.5 0.492

Holder Pluggable function module
Holder Relay Pluggable function module

2CDC292007F0211

23.5 0.925 8 0.315

CR- P/Mxx function module

2CDC292006F0211

CR-P optocoupler
Marker

21

COM

11

24

NO

14

22

NC

12

62 2.441 61 2.402 42.5 1.673

Relay

78.5 3.091

3.2 0.126

20.32 0.8 5.08 5.08 0.2 0.2

29.4 1.158

A2

COIL

A1

7.62 0.3
15.5 0.610

24 0.945 50 1.969

Holder
Pluggable function module

CR-PLSx - screw connection

7.62 0.3

21

11

24

14

22

12

43.5 1.713 33.8 1.331 24.4 0.961

97.5 3.939

5.08 0.2

20.32 0.8

5.08 0.2

25.9 1.019 2CDC292010F0011

A2

A1

16.3 0.642
34.4 1.354
CR-PLC - spring connection

9x15 (=139.5) 9x0.591 (=5.492)
15.5±0.2 0.610±0.008

2±0.2 0.079±0.008

6±0.2 0.236±0.008

141.5+1 5.571+0.039

CR-PJ jumper bar

10 0.394 R1

10 0.394 1.5 0.059
2CDC292012F0011

434

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Pluggable interface relays and optocouplers Technical diagrams

-- Dimensional drawings in mm and inches

6.2 6.3 6.3 4.1 27.5 1.083

35.6 1.402

6.2 6.3 6.3 4.1 27.5 1.083

35.6 1.402

6.2 6.3 6.3 4.1 27.5 1.083

35.6 1.402

2CDC292003F0015

2CDC292002F0015

2CDC292001F0015

2CDC292005F0011

6.5

6.6 0.259 21.2 0.835 2.2x0.5 0.086x0.019
CR-M relay with 2 c/o contacts

6.5

6.6 0.259 21.2 0.835 2.2x0.5 0.086x0.019
CR-M relay with 3 c/o contacts

6.5

4.4 4.4 4.4 21.2 0.835 2.2x0.5 0.086x0.019
CR-M relay with 4 c/o contacts

27.2 1.071 Marker 27.2 1.071

12

11

COM

10

9

41

31

21

11

8

7

NO

6

5

44 34

24

14

4

3

NC

2

1

42 32

22 12

9

8 COM

7

31

21

11

6

5 NO

4

34

24

14

3

2

1

32

22

12

27.2 1.071

12

11

COM

10

9

41

31

21

11

8

7

NO

6

5

44

34

24

14

4

3

NC

2

1

42

32

22

12

60.8 2.394
42.6 1.677 24 0.945

75 2.953 35.4 1.394

A2

A2

A1

14

14 COIL 13

CR-M2LS

A2

A2

A1

14

14

COIL

13

CR-M3LS

A2

A2

A1

14

14

COIL

13

CR-M4LS

29.1 1.456

CR-M2LS - CR-M3LS - CR-M4LS - screw connection

Relay Holder
Pluggable function module

2CDC 292 003 F0211 66.7 2.626 35.4 1.394

30.3 1.923

8 7 NO 6 5

44 34

24 14

4 3 NC 2 1

42 32

22 12

29 1.413 max 19 0.748

14 A2 41 31

A1 13 21 11

12 11 COM 10 9

CR-MxSF - screw connection

42.5 1.673

10 0.394

33.2 1.307

31 1.221

24 0.945

R1

12

11 COM 10

9

12.4 0.488 12.4 0.488

41

31

21

11

8

7 NO 6

5

44

34

24

14

4

3 NC 2

1

42

32

22

12

1 5 0.591

95 3.740

5.5 0.217

14 A2

COIL

13 A1

27 1.063 26 1.024
79.5 3.129
CR-M2LC , CR-M4LC - spring connection

9 x 27.2 (=244.8) 9 x 1.071 (=9.638) 246.8 9.717

6±0.2 0.236±0.0079
9.5 0.374 1
0.0394

Marker

27.2 1.071

27.2 1.071

27.2 1.071

8

7

NO 6

5

6

NO

5

4

8

NO

5

44 34

24 14

34

24

14

44

14

4

3

NC

2

1

3

NC

2

1

4

NC

1

42 32

22 12

32

22

12

42

12

42.6 1.677 24 0.945

75.2 2.961 35.4 1.395

A2 COIL

COIL A1

14 41 31

21 11

12 11 COM 10 9

A2 COIL

14 31

9

COM

COIL A1

13

21

11

8

7

A2 COIL

COIL A1

14

13

41

11

12

COM

9

CR-M2SS - CR-M3SS - CR-M4SS - screw connection

1.0709±0.0079

27.2 ±0.2

Relay Holder

0.079±0.0079

2±0.2

2CDC292004F0211

Pluggable function module

CR-MJ jumper bar

2CDC292011F0011

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

435

-- Pluggable interface relays and optocouplers Technical diagrams

-- Dimensional drawings in mm and inches

2CDC 292 025 F0004
35 1.378
2CDC 292 026 F0004

35 1.378

70 2.756 2CDC292081F0004

35 1.378

13 0.512

CR-U relay with 2 c/o contacts

54.4 2.142

37.3 1.466 24 22 12 14 6 54 3

38.1 1.5
34 32 24 22 14 12
98 7 5 3 4
12 - M3

75.3 2.965

9 - M3

78 1

2

A2 A2 21 11 A1

29.8 1.173 CR-U2S
CR-U2S - CR-U3S - screw connection

10 11 6 1 2 A2 A2 31 21 11 A1
29.8 1.173 CR-U3S

75.3 2.965 35.4 1.394

35 1.378

13 0.512

CR-U relay with 3 c/o contacts

54.4 2.142

38 1.496

34 32 24 22 14 12 9 87 5 3 4

Ø4.2 0.165

37.5 1.476 Ø3.2 0.126

0.52.261

32.5 1.279

4 0.157

2CDC292008F0011

10

2

11 6 1

A2

A1

31

11

21

30 1.181

CR-U3E - screw connection

26 1.024

38.1 1.5 27.8 1.094

38.1 1.5 27.8 1.094

26 1.024

8.5 0.335

23.2 0.913

2CDC 292 020 F0005

8 0.315

61.8 2.433 61.8 2.433 35.4 1.394
2CDC292009F0011

8 - M3

CR-U2SM

11 - M3

CR-U3SM

CR-U2SM - CR-U3SM - screw connection

4 0.158

34.0 1.339
CR-Uxx function module

436

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

437

-- Boxed interface relays and optocouplers R600 range Table of contents

438

Overview

440

Boxed interface relays R600 range

440

Selection table

442

Ordering details

444

Technical data

448

Technical diagrams

450

Boxed optocouplers R600 range

450

Selection table

451

Ordering details

453

Technical data

456

Technical diagrams

438

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed interface relays and optocouplers R600 range Overview

ABB's R600 range may be used in applications where electrical isolation, amplification and signal matching are required. The slim, compact design, incorporated with the variety of terminal connections available allow for the optimization of space within a control panel. This broad portfolio allows for the flexibility of choice and includes both electromagnetic relays and optocouplers.

Continuous operation

The ABB boxed interface relays portfolio incorporates a large assortment of non-pluggable relays. It includes both electro-mechanical relays and optocouplers. The R600 Optocouplers allow for continuous operation without any mechanical wear-and -tear.

Space saving

The 6 mm slim housing of the R600 boxed interface relays provides the possibility of space saving within control cabinets . The 75 mm depth of these relays allows for the use in compact cabinets.

The ABB boxed interface relays are approved for a large variety of applications and adhere to highest Global availability levels of global approvals (UL, CSA, VDE, CCC).

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

439

-- Boxed interface relays and optocouplers R600 range Overview

Complete product line 1 n/o, 1 n/c, 1 c/o, 2 c/o output configuration. Standard contact material for switching high current signals as well as gold-plated contacts for reliable switching of low current signals.

2 DPDT

Marine certification The R600 range offers the LR approval, which allows usage of the boxed interface relays and optocouplers in many applications around the marine segment. The performance of the R600 range has been proven by successfully passing tests required for operating under harsh conditions.

Safe operation High resistance to vibration and shock thanks to the relay soldered inside of the housing. Wrong relay replacement or relay lose not possible . Devices with immunity to leakage currents.

Transistor

MOS-FET

Triac

Longevity Optocoupler with transistor, MOS-FET and Triac output ensure a longer lifetime, higher reliability and quiet operation.

Easy to mount The R600 interface relays and optocouplers are easy to mount by snapping onto a DIN-rail according to IEC/EN 60715. Time saving wiring thanks to a jumper bar.

JJ J J J

JJ

JJ

J

J J J JJ

JJ

JJ JJJ J JJ

JJ J

J JJJ

J

J

11

1111

111122111111

1111111

JJ

JJ J

JJ

J

J

J

JJ

J JJJ JJJJJJJJ J

Input voltage 5 V DC 12 V DC 24 V DC 48-60 V DC 115 V DC 230 V DC 60-230 V DC 24 V AC 48-60 V AC 115 V AC 230 V AC 60-230 V AC Output rating 10 mA - 6 A 3 mA - 6 A 1 mA - 8 A Output contacts c/o n/o n/c Gold plated contacts Terminal type Screw Spring

JJJ JJJJ JJJJJJJJJJJJJJJJ JJ
JJJJJJJJJJJJ JJ

Type
RB121P-5VDC RB121PG-5VDC RBR121P-5VDC RB121-12VDC RB121P-12VDC RB121G-12VDC RBR121P-12VDC RB101R-24VUC RBR101R-24VUC RB111-24VUC RB111R-24VUC RBR111R-24VUC RBR111-24VUC RB121-24VUC RB121G-24VUC RBR121-24VUC RBR121G-24VUC RB122G-24VUC RBR122G-24VUC RB121-24VDC RBR121-24VDC RB121G-24VDC RBR121G-24VDC RB121-48-60VUC RB121G-48-60VUC

Order number
1SNA645034R2300 1SNA645036R2500 1SNA645534R2500 1SNA645073R0000 1SNA645035R2400 1SNA645075R0000 1SNA645535R2600 1SNA645019R0400 1SNA645519R0600 1SNA645014R2700 1SNA645018R0300 1SNA645518R0500 1SNA645514R2100 1SNA645001R0300 1SNA645005R0700 1SNA645501R0500 1SNA645505R0100 1SNA645012R2500 1SNA645512R2700 1SNA645071R0000 1SNA645571R0000 1SNA645072R0000 1SNA645572R0000 1SNA645002R0400 1SNA645006R0000

-- Boxed interface relays R600 range Selection table

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

440

JJJ J J

JJ J

JJ J

JJ

J JJJJJ

J JJJ

J JJ

J

JJJ

JJJ J

11

1111112211

11221111122

JJ

JJ

JJ

J

J

J

J

J

JJ

JJJ JJ J

J JJ

J

JJJJ JJJJJJJJ JJJJJJJJJ JJ

Input voltage 5 V DC 12 V DC 24 V DC 48-60 V DC 115 V DC 230 V DC 60-230 V DC 24 V AC 48-60 V AC 115 V AC 230 V AC 60-230 V AC Output rating 10 mA - 6 A 3 mA - 6 A 1 mA - 8 A Output contacts c/o n/o n/c Gold plated contacts Terminal type Screw Spring

JJJJ JJJJJJJJ JJJJJJJJJ JJ

Type RBR121-48-60VUC RBR121G-48-60VUC RB122G-48-60VUC RBR122G-48-60VUC RB121-115VUC RB121G-115VUC RB121R-115VUC RBR121-115VUC RBR121G-115VUC RB122G-115VUC RBR122G-115VUC RB111-115VUC RB111-230VUC RB121-230VUC RB121G-230VUC RB121R-230VUC RBR121-230VUC RBR121G-230VUC RBR121R-230VUC RB122G-230VUC RBR122G-230VUC RB121-60-230VUC RBR121-60-230VUC

Order number 1SNA645502R0600 1SNA645506R0200 1SNA645040R1500 1SNA645540R1700 1SNA645003R0500 1SNA645007R0100 1SNA645046R0700 1SNA645503R0700 1SNA645507R0300 1SNA645041R0200 1SNA645541R0400 1SNA645016R2100 1SNA645017R2200 1SNA645004R0400 1SNA645008R1200 1SNA645011R2400 1SNA645504R0000 1SNA645508R1400 1SNA645511R2600 1SNA645013R2600 1SNA645513R2000 1SNA645020R0100 1SNA645520R0300

-- Boxed interface relays R600 range Selection table

441

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

442

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed interface relays R600 range Ordering details

R600 - 6 mm

2CDC 291 024 S0013

The R600 range comprises of boxed interface relays and optocouplers. In this range, the relay is soldered into device housing, fulfilling the highest vibration requirements. This compact range of relays are 6 mm wide and provide the possibility of switching AC and DC circuits with the same relay. All the sockets in this range are equipped with an indicator LED and available with screw or spring terminals.

-- Ordering details - 1 n/c contact: 250 V, 10 mA - 6 A, width 12 mm

Rated control supply voltage

Connection type Particularities Type

24 V AC/DC

screw spring

RC circuit parallel to output contact

RB101R-24VUC RBR101R-24VUC

Order code

Pkg

qty

1SNA645019R0400 5 1SNA645519R0600

Weight (1 pc.) kg (lb)
0.04 (0.088)

-- Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A, width 6 mm

Rated control supply voltage

Connection type Particularities Type

24 V AC/DC 115 V AC/DC 230 V AC/DC 24 V AC/DC

screw screw screw spring

RB111-24VUC RB111-115VUC RB111-230VUC RBR111-24VUC

Order code

Pkg

qty

1SNA645014R2700 10 1SNA645016R2100 1SNA645017R2200 1SNA645514R2100

Weight (1 pc.) kg (lb)
0.02 (0.044)

-- Ordering details - 1 n/o contact: 250 V, 10 mA - 6 A, width 12 mm

Rated control supply voltage

Connection type Particularities Type

24 V AC/DC

screw spring

RC circuit parallel to output contact

RB111R-24VUC RBR111R-24VUC

Order code

Pkg

qty

1SNA645018R0300 5 1SNA645518R0500

Weight (1 pc.) kg (lb)
0.04 (0.088)

-- Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A, width 6 mm

Rated control supply voltage

Connection type Particularities Type

Order code

Pkg

qty

5 V DC 12 V DC 12 V DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC 5 V DC 12 V DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC

screw screw screw screw screw screw screw screw spring spring spring spring spring spring spring

A1-A2 polarized A1-A2 polarized
A1-A2 polarized A1-A2 polarized

RB121P-5VDC RB121P-12VDC RB121-12VDC RB121-24VDC RB121-24VUC RB121-48-60VUC RB121-115VUC RB121-230VUC RBR121P-5VDC RBR121P-12VDC RBR121-24VDC RBR121-24VUC RBR121-48-60VUC RBR121-115VUC RBR121-230VUC

1SNA645034R2300 10 1SNA645035R2400 1SNA645073R0000 1SNA645071R0000 1SNA645001R0300 1SNA645002R0400 1SNA645003R0500 1SNA645004R0400 1SNA645534R2500 1SNA645535R2600 1SNA645571R0000 1SNA645501R0500 1SNA645502R0600 1SNA645503R0700 1SNA645504R0000

Weight (1 pc.) kg (lb)
0.02 (0.044)

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

443

-- Boxed interface relays R600 range Ordering details

R600 - 12 mm

2CDC 291 013 S0013

-- Ordering details - 1 c/o (SPDT) contact: 250 V, 3 mA - 6 A, gold-plated contacts, width 6 mm

Rated control supply voltage

Connection type Particularities Type

Order code

Pkg

qty

5 V DC 12 V DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC

screw screw screw screw screw screw screw spring spring spring spring spring

A1-A2 polarized RB121PG-5VDC

1SNA645036R2500 10

RB121G-12VDC

1SNA645075R0000

RB121G-24VDC

1SNA645072R0000

RB121G-24VUC

1SNA645005R0700

RB121G-48-60VUC 1SNA645006R0000

RB121G-115VUC

1SNA645007R0100

RB121G-230VUC

1SNA645008R1200

RBR121G-24VDC

1SNA645572R0000

RBR121G-24VUC

1SNA645505R0100

RBR121G-48-60VUC 1SNA645506R0200

RBR121G-115VUC 1SNA645507R0300

RBR121G-230VUC 1SNA645508R1400

Weight (1 pc.) kg (lb)
0.02 (0.044)

-- Ordering details - 1 c/o (SPDT) contact: 250 V, 10 mA - 6 A, width 12 mm

Rated control supply voltage

Connection type

Particularities Type

Order code

Pkg

qty

60-230 V AC/DC 115 V AC/DC 230 V AC/DC
60-230 V AC/DC 230 V AC/DC

screw screw screw
spring spring

Leakage current protection, RC circuit parallel to input
Leakage current protection, RC circuit parallel to input

RB121-60-230VUC RB121R-115VUC RB121R-230VUC

1SNA645020R0100 5 1SNA645046R0700 1SNA645011R2400

RBR121-60-230VUC 1SNA645520R0300 RBR121R-230VUC 1SNA645511R2600

Weight (1 pc.) kg (lb)
0.04 (0.088)

-- Ordering details - 2 c/o (SPDT) contacts: 250 V, 1 mA - 8 A, gold-plated contacts, width 12 mm

Rated control supply voltage
24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V AC/DC 48-60 V AC/DC 115 V AC/DC 230 V AC/DC

Connection type
screw screw screw screw spring spring spring spring

Type

Order code

Pkg

qty

RB122G-24VUC RB122G-48-60VUC RB122G-115VUC RB122G-230VUC RBR122G-24VUC RBR122G-48-60VUC RBR122G-115VUC RBR122G-230VUC

1SNA645012R2500 5 1SNA645040R1500 1SNA645041R0200 1SNA645013R2600 1SNA645512R2700 1SNA645540R1700 1SNA645541R0400 1SNA645513R2000

Weight (1 pc.) kg (lb)
0.04 (0.088)

-- Ordering details - Accessories
Description
Jumper bar, 10 poles * (replacement of BJ612-10 - 1SNA290488R0100) Jumper bar, 20 poles * (replacement of BJ612-20 - 1SNA206754R0000) Separator end section

Type
RB-JB10 RB-JB20 SC612

Order code

Pkg

qty

1SVR406570R0000 10

1SVR406580R0000

1SNA290474R0200

* - Before the first and after the last jumpered R600 relay, a separator end section shall be used. - The sum of the current for jumpered devices shall not exceed 6 A on 6 mm devices and 8 A on 12 mm devices.

Weight (1 pc.) kg (lb)
0.05 (0.11)
0.10 (0.22)
0.05 (0.11)

444

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed interface relays R600 range Technical data

RB(R)101R-

RB(R)111R-

24 V UC

24 V UC

Input circuit

Rated control supply voltage Us Rated control supply voltage Us tolerance

24 V AC/DC DC -15 %, +20 % AC -/+ 10 %

Rated frequency

50/60 Hz

Typical power consumption

0.24 W

Typical current

10 mA

Drop-out voltage

at 20 °C 4.5 V

Indication of operational states

green LED V: control supply voltage applied

Output circuit

Kind of output

11-12 relay, 1 n/c contact

-

13-14 -

relay, 1 n/o contact

Rated operational voltage Ue Minimum switching voltage

250 V AC 5 V

Maximum switching voltage

250 V AC

Minimum switching current

60 mA

Rated free air thermal current Ith Rated operational current Ie

6 A AC-12 (resistive) 230 V 6 A AC-15 (inductive) 230 V 1.5 A

AC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 A

DC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 A

DC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

utilization category (pilot duty) B300

DC rating (UL 508; NEMA ICS-5)

utilization category (pilot duty) R300

Minimum switching power

300 mW

Mechanical lifetime

1 x 107 switching cycles

Electrical lifetime

at AC-15 1 x 105 switching cycles

Max. fuse rating to achieve short-circuit protection

6 A fast

Response time

5 ms

Release time

8 ms

Input circuit Rated control supply voltage Us Rated control supply voltage Us tolerance
Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states
Output circuit Kind of output Rated operational voltage Ue Minimum switching voltage Maximum switching voltage Minimum switching current Rated free air thermal current Ith

RB(R)11124 V UC

115 V UC

24 V AC/DC

115 V AC/DC

DC -15 %, +20 %

AC -/+ 10 %

50/60 Hz

0.24 W

0.46 W

10 mA

4 mA

at 20 °C 4.5 V

17 V

green LED V: control supply voltage applied

13-14 relay, 1 n/o contact 250 V AC 12 V 250 V AC 10 mA 6 A

230 V UC
230 V AC/DC -15 %, +10 %
0.8 W 3.5 mA 27 V

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

445

-- Boxed interface relays R600 range Technical data

RB(R)111-

24 V UC

Rated operational current Ie

AC-12 (resistive) 230 V 6 A AC-15 (inductive) 230 V 1.5 A

AC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 A

DC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 A

DC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

utilization category (pilot duty) B300

DC rating (UL 508; NEMA ICS-5) utilization category (pilot duty) R300

Minimum switching power

300 mW

Mechanical lifetime

1 x 107 switching cycles

Electrical lifetime

at AC-15 1 x 105 switching cycles

Max. fuse rating to achieve short-circuit protection

6 A fast

Response time

5 ms

Release time

8 ms

115 V UC
6 ms 15 ms

230 V UC
7 ms 15 ms

RB(R)121(P)(G)-

5 V DC 12 V DC 24 V DC 24 V UC

Input circuit

Rated control supply voltage Us Rated control supply voltage Us tolerance

5 V DC 12 V DC DC -15 %, +20 % AC -

24 V DC

24 V AC/DC -/+ 10 %

Rated frequency

-

50/60 Hz

Typical power consumption

0.2 W 0.2 W 0.24 W

Typical current

40 mA 16 mA 10 mA

Drop-out voltage

at 20 °C 1.2 V 2.2 V

4.5 V

Indication of operational states

green LED control supply voltage applied

Output circuit

Kind of output

11-12/14 relay, 1 c/o (SPDT) contact

Rated operational voltage Ue Minimum switching voltage

250 V AC 5 V / gold-plated contacts: 5 V

Maximum switching voltage

250 V AC

Minimum switching current

60 mA / gold-plated contacts: 10 mA

Rated free air thermal current Ith

6 A

Rated operational

AC-12 (resistive) 230 V 6 A

current Ie

AC-15 (inductive) 230 V 1.5 A

AC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 A

DC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 A

DC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

utilization category B300 (pilot duty)

DC rating (UL 508; NEMA ICS-5)

utilization category R300 (pilot duty)

Minimum switching power

300 mW / gold-plated contacts: 50 mW

Mechanical lifetime

1 x 107 switching cycles

Electrical lifetime

at AC-15 1 x 105 switching cycles

Max. fuse rating to achieve shortcircuit protection

6 A fast

Response time

5 ms 5 ms

5 ms

Release time

8 ms 8 ms

8 ms

48-60 V UC 48 V AC/DC 0.33 W 7 mA 8 V
5 ms 8 ms

60 V AC/DC 0.54 W 9 mA 8 V
5 ms 8 ms

115 V UC 115 V AC/DC 0.46 W 4 mA 17 V
6 ms 15 ms

230 V UC 230 V AC/DC -15 %, +10 % 0.8 W 3.5 mA 27 V
7 ms 16 ms

446

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed interface relays R600 range Technical data

RB(R)121R-

115 V UC

Input circuit

Rated control supply voltage Us
Rated control supply voltage Us tolerance

115 V AC/DC DC -20%, +15% AC -/+ 10 %

Rated frequency

50/60 Hz

Typical power consumption

2 W

Typical current

18 mA

Drop-out voltage

at 20 °C 17 V

Indication of operational states

green LED V: control supply voltage applied

Output circuit

Kind of output

11-12/14 relay, 1 c/o (SPDT) contact

Rated operational voltage Ue Minimum switching voltage

250 V AC 5 V

Maximum switching voltage

250 V AC

Minimum switching current

60 mA

Rated free air thermal current Ith

6 A

Rated operational

AC-12 (resistive) 230 V 6 A

current Ie

AC-15 (inductive) 230 V 1.5 A

AC-15 (inductive) 120 V 3 A

DC-12 (resistive) 24 V 6 A

DC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 A

DC-13 (inductive) 220 V 0.1 A

AC rating (UL 508; NEMA ICS-5)

utilization category B300 (pilot duty)

DC rating (UL 508; NEMA ICS-5)

utilization category R300 (pilot duty)

Minimum switching power

300 mW

Mechanical lifetime

1 x 107 switching cycles

Electrical lifetime

at AC-15 1 x 105 switching cycles

Max. fuse rating to achieve short-circuit protection

6 A fast

Response time

6 ms

Release time

15 ms

230 V UC 230 V AC/DC -10%, +15% 2.8 W 12 mA 27 V
7 ms 16 ms

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

447

-- Boxed interface relays R600 range Technical data

RB(R)122G

24 V UC

48-60 V UC

Input circuit

Rated control supply voltage Us
Rated control supply voltage Us tolerance

24 V AC/DC DC -15 %, +20 % AC -/+ 10 %

48 V AC/DC

60 V AC/DC

Rated frequency

50/60 Hz

Typical power consumption

0.48 W

0.62 W

0.96 W

Typical current

20 mA

13 mA

16 mA

Drop-out

at 20 °C 5.4 V

8.8 V

8.8 V V

Indication of operational states

green LED V: control supply voltage applied

Output circuit

Kind of output

11-12/14 relay, 1st c/o (SPDT) contact

21-22/24 relay, 2nd c/o (SPDT) contact

Rated operational voltage Ue Minimum switching voltage

250 V AC 5 V / gold-plated contacts: 5 V

Maximum switching voltage

250 V

Minimum switching current

60 mA / gold-plated contacts: 10 mA

Rated free air thermal current Ith

8 A

Rated operational

AC-12 (resistive) 230 V 8 A

current Ie

AC-15 (inductive) 230 V 1.5 A

DC-12 (resistive) 24 V 8 A

DC-13 (inductive) 24 V 1 A

DC-13 (inductive) 110 V 0.2 A

DC-13 (inductive) 220 V 0.1 A

Minimum switching power

300 mW / gold-plated contacts: 50 mW

Mechanical lifetime

2 x 107 switching cycles

Electrical lifetime

at AC-15 1 x 105 switching cycles

Max. fuse rating to achieve short-circuit protection 10 A fast

Response time

6 ms

10 ms

10 ms

Release time

10 ms

14 ms

14 ms

115 V UC 115 V AC/DC

230 V UC
230 V AC/DC -15 %, +10 %

0.58 W 5 mA 20 V

1.15 W 5 mA 10 V

6 ms 15 ms

6 ms 15 ms

-- General technical data - Interface relays

RB

RBR

General data

Material of housing

UL 94 V0

Mounting

DIN rail

Degree of protection

housing / terminals IP20 NEMA1

Electrical connection

Screw terminal

Spring-type terminal

Connecting capacity

fine-strand 0.22-2.5 mm² (24-14 AWG)

rigid 0.2-4 mm² (24-12 AWG)

0.2-2.5 mm² (24-14 AWG)

Stripping length

9 mm (0.354 in)

Tightening torque

0.4-0.6 Nm (3.5-5.3 lb.in)

n/a

Environmental data

Ambient temperature ranges

storage -40...+80 °C (-40...+176 °F)

operation -20...+70 °C (-4...+158 °F) 1)

Isolation data

Rated insulation voltage Ui

250 V

Rated impulse withstand voltage Uimp

input / output 4 kV shock coil / output 4 kV

output / output 1 kV

Overvoltage category

III

Pollution degree

2

Standards/Directives

Standards

IEC/EN 60947-5-1

Low Voltage Directive

2014/35/EC

RoHS Directive

2011/65/EC

1) Over 55 °C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting max. operation temperature is 15 °C lower.

448

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed interface relays R600 range Technical diagrams

-- Load limit curves

DC voltage [V]

300 200

100

resistive load

50 40

30

20

10 0.1 0.2 0.5 1 2

5

10 20

DC current [A]

Versions with 1 n/o, 1 n/c or 1 c/o contact

-- Dimensional drawings in mm and inches
70 2.76"

2CDC292002F0212

DC voltage [V]

300 200

100

resistive load

50 40
30

20

10 0.1 0.2 0.5 1 2
Versions with 2 c/o contacts

5 10 20
DC current [A]

75 2.95"

2CDC292028F0213

67.5 2.66" 75 2.95"

67.5 2.66" 75 2.95"

A2 A1
S1
S2 13
14
A2 A1
S1
S2 12
11 14

2CDC292026F0013

2CDC292025F0013

35 1.38" R600 - screw connection

37.5 1.48" R600 - spring connection

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

449

-- Boxed interface relays R600 range Technical diagrams

2CDC292033F0013

2CDC292038F0013

-- Connection diagrams
12 A1

A2 S1
RB(R)101R - 24VUC

S2 11

13 A1

A2 S1
RB(R)111R-24VUC

S2 14

12 14 A1

A2 S1
RB(R)121(G)-24VUC

S2 11

12 14 22 24 A1

A2

11 21

S1

RB(R)122G-24VUC/48-60VUC

2CDC292043F0013

2CDC292039F0013

2CDC292035F0013

2CDC292030F0013

13 A1

A2 S1
RB(R)111-24VUC

S2 14

12 14 A1

A2
S1 S2 11
RB(R)121P(G)-5VDC/12VDC

12 14 A1

A2 S1
S2 11 RB(R)121(G)-48-60VUC/ 115VUC/230VUC/60-230VUC
12 14 22 24 A1

A2 S1
RB(R)122G-115VUC/230VUC

11 21

2CDC292044F0013

2CDC292040F0013

2CDC292036F0013

2CDC292031F0013

13 A1

A2 S1
RB111-115VUC/230VUC

S2 14

12 14 A1

A2 S1
RB(R)121-12VDC/24VDC

S2 11

12 14 A1

A2 S1
RB(R)121R-115VUC/230VUC

S2 11

2CDC292042F0013

450

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed optocouplers R600 range Selection table

Input voltage 5-12 V DC 24 V DC 48-60 V DC 115-230 V DC 115 V DC 230 V DC 24 V AC 48-60 V AC 115-230 V AC 115 V AC 230 V AC Output rating 100 mA 1 A 2 A 5 A Output voltage 58 V DC 230 V AC 400 V AC Terminal type Screw Spring Kind of output Transistor MOS-FET Triac

Type

Order number

JJ

JJ

JJJJJJJJ

JJ

JJ

JJ

JJ

JJ

JJ

JJJJJJ

J

J

JJJJ JJ JJJ JJ

J

JJJJJJJJJJJJJJJJJJJJJJJ JJ
J J JJ

J J J J J JJJ

JJJJJ

J

JJJ J

JJJJJJJJ JJJJJJJJJJJJJJJ JJJJJJ

OBIC0100-5-12VDC

1SNA645047R0000

OBRIC0100-5-12VDC 1SNA645547R0200

OBIC0100-24VDC

1SNA645021R2600

OBRIC0100-24VDC

1SNA645521R2000

OBIC0100-48-60VUC 1SNA645049R1200

OBRIC0100-48-60VUC 1SNA645549R1400

OBIC0100-115-230

1SNA645022R2700

OBRIC0100-115-230

1SNA645522R2100

OBOC2000-5-12VDC

1SNA645050R1700

OBROC2000-5-12VDC 1SNA645550R1100

OBOC2000-24VDC

1SNA645051R0400

OBOC2000-24VUC

1SNA645025R2200

OBOC5000-24VDC

1SNA645024R2100

OBROC2000-24VDC

1SNA645551R0600

OBROC2000-24VUC

1SNA645525R2400

OBROC5000-24VDC

1SNA645524R2300

JJ

JJ

JJ

JJ

J JJJ

OBOC2000-48-60VUC 1SNA645053R0600

OBROC2000-48-60VUC 1SNA645553R0000

OBOC2000-115VUC

1SNA645054R0700

J

OBOC5000-115VUC

1SNA645058R1300

JJJ

JJJ

OBOC2000-230VUC

1SNA645026R2300

JJ

OBROC2000-230VUC 1SNA645526R2500

J

OBROC5000-230VUC 1SNA645559R1600

JJJJ

J J JJ

JJ

OBOA1000-24VDC

1SNA645027R2400

JJ

OBOA2000-24VDC

1SNA645029R0600

JJ

OBROA1000-24VDC

1SNA645527R2600

OBROA2000-24VDC

1SNA645529R0000

J

J

JJ

OBOA1000-115VUC

1SNA645062R0700

J

J

OBOA1000-230VUC

1SNA645028R0500

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

451

-- Boxed optocouplers R600 range Ordering details

R600 - 6 mm

2CDC 291 024 S0013

-- Ordering details - Transistor output, 58 V DC, 100 mA, width 6 mm

Rated control supply voltage

Connection type

Type

Order code

5 - 12 V DC 24 V DC 48 - 60 V AC/DC 115 - 230 V AC/DC 5 - 12 V DC 24 V DC 48 - 60 V AC/DC 115 - 230 V AC/DC

screw screw screw screw spring spring spring spring

OBIC0100-5-12VDC OBIC0100-24VDC OBIC0100-48-60VUC OBIC0100-115-230 OBRIC0100-5-12VDC OBRIC0100-24VDC OBRIC0100-48-60VUC OBRIC0100-115-230

1SNA645047R0000 1SNA645021R2600 1SNA645049R1200 1SNA645022R2700 1SNA645547R0200 1SNA645521R2000 1SNA645549R1400 1SNA645522R2100

Pkg Weight qty (1 pc.)
kg (lb) 10 0.02
(0.044)
10 0.02 (0.044)

-- Ordering details - MOS-FET output, 58 V DC, 2 A, width 6 mm

Rated control supply voltage

Connection type

Type

Order code

5 - 12 V DC 24 V DC 24 V AC/DC 48 - 60 V AC/DC 115 V AC/DC 230 V AC/DC 5 - 12 V DC 24 V DC 24 V AC/DC 48 - 60 V AC/DC 230 V AC/DC

screw screw screw screw screw screw spring spring spring spring spring

OBOC2000-5-12VDC 1SNA645050R1700

OBOC2000-24VDC

1SNA645051R0400

OBOC2000-24VUC

1SNA645025R2200

OBOC2000-48-60VUC 1SNA645053R0600

OBOC2000-115VUC

1SNA645054R0700

OBOC2000-230VUC

1SNA645026R2300

OBROC2000-5-12VDC 1SNA645550R1100

OBROC2000-24VDC

1SNA645551R0600

OBROC2000-24VUC

1SNA645525R2400

OBROC2000-48-60VUC 1SNA645553R0000

OBROC2000-230VUC 1SNA645526R2500

Pkg qty 10
10

Weight (1 pc.) kg (lb) 0.02 (0.044)
0.02 (0.044)

-- Ordering details - MOS-FET output, 58 V DC, 5 A, width 6 mm

Rated control supply voltage

Connection type

Type

Order code

24 V DC 115 V AC/DC 24 V DC 230 V AC/DC

screw screw spring spring

OBOC5000-24VDC OBOC5000-115VUC OBROC5000-24VDC OBROC5000-230VUC

1SNA645024R2100 1SNA645058R1300 1SNA645524R2300 1SNA645559R1600

Pkg Weight qty (1 pc.)
kg (lb)
10 0.02 (0.044)
10 0.02 (0.044)

-- Ordering details - Triac output, 400 V AC, 1 A, width 6 mm

Rated control supply voltage

Connection type

Type

24 V DC 115 V AC/DC 230 V AC/DC 24 V DC

screw screw screw spring

OBOA1000-24VDC OBOA1000-115VUC OBOA1000-230VUC OBROA1000-24VDC

Order code
1SNA645027R2400 1SNA645062R0700 1SNA645028R0500 1SNA645527R2600

Pkg Weight qty (1 pc.)
kg (lb) 10 0.03
(0.066)
10

452

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed optocouplers R600 range Ordering details

R600 - 12 mm

2CDC 291 013 S0013

-- Ordering details - Triac output, 230 V AC, 2 A, width 12 mm

Rated control supply voltage

Connection type

Type

Order code

24 V DC 24 V DC

screw spring

OBOA2000-24VDC OBROA2000-24VDC

1SNA645029R0600 1SNA645529R0000

Pkg Weight qty (1 pc.)
kg (lb)

5

0.03

5

(0.066)

-- Ordering details - Accessories

Description

Type

Jumper bar, 10 poles *

RB-JB10

(replacement of BJ612-10 - 1SNA290488R0100)

Jumper bar, 20 poles *

RB-JB20

(replacement of BJ612-20 - 1SNA206754R0000)

Separator end section

SC612

Order code

Pkg Weight qty (1 pc.)
kg (lb)

1SVR406570R0000 10

0.05 (0.11)

1SVR406580R0000

0.10 (0.22)

1SNA290474R0200

0.05 (0.11)

* - Before the first and after the last jumpered R600 optocoupler, a separator end section shall be used. - The sum of the current for jumpered devices shall not exceed 6 A on 6 mm devices and 8 A on 12 mm devices.

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

453

-- Boxed optocouplers R600 range Technical data

Input circuit Input voltage Frequency Input current

OB(R)IC0100-... 5-12 V DC

5 V DC 5 mA

12 V DC 9 mA

Pull-in voltage

4 V

Typ. switch-on time

10 µs

Typ. switch-off time

500 µs

Operating frequency

1000 Hz

Permissible leakage current

0.9 mA

Output circuit

11(13+)- 14

Kind of output

Transistor

Rated operational voltage

4.5-58 V DC

Minimum switching current

1 mA

Maximum switching current

100 mA

Leakage current at max. switching voltage

< 50 µA

Rated operational current Ie (IEC/EN 60947-5-1)

DC-12 (resistive) 58 V 0.1 A

Residual voltage

typical 1 V

maximum 1.3 V

Max. fuse rating to achieve short-circuit protection 100 mA fast

Isolation data

Rated insulation voltage Ui

250 V

Rated impulse withstand voltage Uimp

2.5 kV

Overvoltage category

II

Pollution degree

2

24 V DC 24 V DC 4 mA 15 V
1.0 mA

48-60 V UC

115-230

48 V AC/DC 50/60 Hz 4 mA
25 V 5 ms 20 ms
0.9 mA

60 V AC/DC 115 V AC/DC 230 V AC/DC

5 mA

7 mA (AC) 11.5 mA (AC) 16 mA (DC) 25 mA (DC)
60 V AC / 70 V DC

20 Hz

1.6 mA

OB(R)OC2000-...

5-12 V DC

Input circuit

Input voltage

5 V DC

12 V DC

Frequency

-

Input current

5 mA

9 mA

Pull-in voltage

4 V

Typ. switch-on time

15 µs

Typ. switch-off time

250 µs

Operating frequency

2000 Hz

Permissible leakage current

1 mA

Output circuit

11(13+)- 14

Kind of output

MOS-FET

Rated operational voltage

4.5-58 V DC

Minimum switching current

1 mA

Maximum switching current

2 A

Leakage current at max. switching voltage

< 50 µA

Rated operational current Ie Residual voltage

DC-12 (resistive) 58 V 2 A typical 0.1 V

maximum 0.5 V

Max. fuse rating to achieve short-circuit protection 2 A ultra-fast

Isolation data

Rated insulation voltage Ui Rated impulse withstand voltage Uimp Overvoltage category

250 V 2.5 kV II

Pollution degree

2

24 V DC 24 V UC

48-60 V UC

115 V UC 230 V UC

24 V DC
5.4 mA 12 V 30 µs 400 µs 1000 Hz 0.8 mA

24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC

50/60 Hz

6.3 mA

4 mA

5.1 mA

4.2 mA

4 mA

15 V

27 V

50 V

80 V

1 ms

5 ms

500 µs

1 ms

7 ms

20 ms

10 ms

15 ms

60 Hz

20 Hz

50 Hz

35 Hz

0.9 mA

1 mA

0.3 mA

454

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed optocouplers R600 range Technical data

OB(R)OC5000-...

24 V DC

Input circuit

Input voltage

24 V DC

Frequency

-

Input current

5.4 mA

Pull-in voltage

12 V

Typ. switch-on time

30 µs

Typ. switch-off time

400 µs

Operating frequency

1000 Hz

Permissible leakage current

0.8 mA

Output circuit

11(13+)- 14

Kind of output

MOS-FET

Rated operational voltage

4.5-58 V DC

Minimum switching current

1 mA

Maximum switching current

5 A

Leakage current at max. switching voltage

< 50 µA

Rated operational current Ie Residual voltage

DC-12 (resistive) 58 V 5 A typical 0.1 V

maximum 0.5 V

Max. fuse rating to achieve short-circuit protection 6 A ultra-fast

Isolation data

Rated insulation voltage Ui

250 V

Rated impulse withstand voltage Uimp

2.5 kV

Overvoltage category

II

Pollution degree

2

115 V UC
115 V AC/DC 50/60 Hz 4.2 mA 50 V 500 µs 10 ms 50 Hz 0.3 mA

230 V UC
230 V AC/DC
4 mA 80 V 1 ms 15 ms 35 Hz 0.3 mA

OB(R)OA1000-...

24 V DC

Input circuit

Input voltage

24 V DC

Frequency

-

Input current

3.6 mA

Pull-in voltage

14 V

Typ. switch-on time

150 µs

Typ. switch-off time

1 ms

Operating frequency

500 Hz

Permissible leakage current

1 mA

Output circuit

11(13+)- 14

Kind of output

Triac

Rated operational voltage

24-400 V AC

Minimum switching current

25 mA

Maximum switching current

1 A

Leakage current at max. switching voltage

< 500 µA

Rated operational current Ie

AC-12 (resistive) 400 V 1 A AC-12 (resistive) 230 V -

Residual voltage

typical 1 V

maximum 1.6 V

Max. fuse rating to achieve short-circuit protection 4 A ultra-fast

Isolation data

Rated insulation voltage Ui Rated impulse withstand voltage Uimp Overvoltage category

400 V 4 kV II

Pollution degree

2

115 V UC
115 V AC/DC 50/60 Hz 4.15 mA 60 V 2.2 ms 18 ms 25 Hz

230 V UC
230 V AC/DC
4.6 mA 135 V 2.5 ms 25 ms 20 Hz

OB(R)OA2000-... 24 V DC
24 V DC 3.6 mA 14 V 150 µs 1 ms 500 Hz 1 mA
Triac 10-230 V AC 25 mA 2 A < 500 µA 2A 1 V 1.6 V 4 A ultra-fast
230 V 4 kV II 2

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

455

-- Boxed optocouplers R600 range Technical data

-- General technical data - Optocouplers

General data Material of housing Mounting Degree of protection Electrical connection Connecting capacity
Stripping length Tightening torque Environmental data Ambient temperature ranges
Standards/Directives Standards Low Voltage Directive RoHS Directive

OB
UL 94 V0 DIN Rail housing / terminals IP20 NEMA1 Screw terminal fine-strand 0.22-2.5 mm² (24-14 AWG) rigid 0.2-4 mm² (24-12 AWG) 9 mm (0.354 in) 0.4-0.6 Nm (3.5-5.3 lb.in)
storage -40...+80 °C (-40...+176 °F) operation -20...+70 °C (-4...+158 °F)
IEC/EN 60947-5-1 2014/35/EU 2011/65/EU

OBR
Spring-type terminal 0.2-2.5 mm² (24-14 AWG) n/a

456

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

-- Boxed optocouplers R600 range Technical diagrams

-- Dimensional drawings in mm and inches
70 2.76"

75 2.95"

67.5 2.66" 75 2.95"

67.5 2.66" 75 2.95"

A2 A1
S1
S2 13
14
A2 A1
S1
S2 12
11 14

2CDC292026F0013

2CDC292025F0013

35 1.38" R600 - screw connection

-- Connection diagrams
A1
A2 S1 OB(R)OC, OB(R)IC except 5-12 V DC versions

13 (+)
14 (-) S2

2CDC292019F0016

37.5 1.48" R600 - spring connection

A1
A2 S1
OB(R)IC0100-5-12 V DC OB(R)OC2000-5-12 V DC

13 (+)
14 (-) S2

2CDC292017F0016

A1
A2 S1 OB(R)OA

13 (+)
14 (-) S2

2CDC292018F0016

ELECTRONIC RELAYS AND CONTROLS CATALOG INTERFACE RELAYS AND OPTOCOUPLERS

457

458

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Product type

Type ADP.01 ADP.01 ADP.02 C011-100 C011-110 C011-120 C011-130 C011-140 C011-150 C011-160 C011-170 C011-3-150 C011-70 C011-80 C011-90 CM-AH-3 CM-CT 100/1 CM-CT 100/5 CM-CT 150/1 CM-CT 150/5 CM-CT 200/1 CM-CT 200/5 CM-CT 300/1 CM-CT 300/5 CM-CT 400/1 CM-CT 400/5 CM-CT 50/1 CM-CT 50/5 CM-CT 500/1 CM-CT 500/5 CM-CT 600/1 CM-CT 600/5 CM-CT 75/1 CM-CT 75/5 CM-CT A CM-EFS.2P CM-EFS.2S CM-ENE MAX CM-ENE MAX CM-ENE MAX CM-ENE MIN CM-ENE MIN CM-ENE MIN CM-ENS.11P CM-ENS.11S CM-ENS.13P CM-ENS.13S CM-ENS.21P CM-ENS.21S CM-ENS.23P CM-ENS.23S

Order code 1SVR430029R0100 1SVR430029R0100 1SVR440029R0100 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0011 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110033R0008 GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 1SVR450056R7000 1SVR450116R1200 1SVR450116R5200 1SVR450116R1300 1SVR450116R5300 1SVR450116R1400 1SVR450116R5400 1SVR450117R1100 1SVR450117R5100 1SVR450117R1200 1SVR450117R5200 1SVR450116R1000 1SVR450116R5000 1SVR450117R1300 1SVR450117R5300 1SVR450117R1400 1SVR450117R5400 1SVR450116R1100 1SVR450116R5100 1SVR450118R1000 1SVR740750R0400 1SVR730750R0400 1SVR550855R9400 1SVR550850R9400 1SVR550851R9400 1SVR550855R9500 1SVR550850R9500 1SVR550851R9500 1SVR730850R2100 1SVR730850R0100 1SVR740850R2100 1SVR740850R0100 1SVR740850R0200 1SVR730850R0200 1SVR740850R2200 1SVR730850R2200

Page 41
242 242 191 191 191 191 191 191 191 191 191 191 191 191 242 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243 243
89 89 229 229 229 229 229 229 229 229 229 229 229 229 229 229

Type CM-ENS.31P CM-ENS.31S CM-ESS.1P CM-ESS.1P CM-ESS.1P CM-ESS.1S CM-ESS.1S CM-ESS.1S CM-ESS.2P CM-ESS.2P CM-ESS.2P CM-ESS.2S CM-ESS.2S CM-ESS.2S CM-ESS.MP CM-ESS.MS CM-GM-1 CM-HC CM-HCT CM-HE CM-IVN.P CM-IVN.S CM-IWM.10 CM-IWM.11 CM-IWN.1P CM-IWN.1S CM-IWS.1P CM-IWS.1S CM-IWS.2P CM-IWS.2S CM-KH-3 CM-MPN.52P CM-MPN.52S CM-MPN.62P CM-MPN.62S CM-MPN.72P CM-MPN.72S CM-MPS.11P CM-MPS.11S CM-MPS.21P CM-MPS.21S CM-MPS.23P CM-MPS.23S CM-MPS.31P CM-MPS.31S CM-MPS.41P CM-MPS.41S CM-MPS.43P CM-MPS.43S CM-MSE CM-MSE

Order code 1SVR740850R0300 1SVR730850R0300 1SVR740830R0300 1SVR740831R0300 1SVR740831R1300 1SVR730830R0300 1SVR730831R0300 1SVR730831R1300 1SVR740830R0400 1SVR740831R0400 1SVR740831R1400 1SVR730830R0400 1SVR730831R0400 1SVR730831R1400 1SVR740830R0500 1SVR730830R0500 1SVR450056R8000 1SVR402902R1000 1SVR402902R2000 1SVR402902R0000 1SVR760669R9400 1SVR750669R9400 1SVR470670R1000 1SVR470670R1100 1SVR760660R0200 1SVR750660R0200 1SVR740660R0100 1SVR730660R0100 1SVR740670R0200 1SVR730670R0200 1SVR450056R6000 1SVR760487R8300 1SVR750487R8300 1SVR760488R8300 1SVR750488R8300 1SVR760489R8300 1SVR750489R8300 1SVR740885R1300 1SVR730885R1300 1SVR740885R3300 1SVR730885R3300 1SVR740885R4300 1SVR730885R4300 1SVR740884R1300 1SVR730884R1300 1SVR740884R3300 1SVR730884R3300 1SVR740884R4300 1SVR730884R4300 1SVR550805R9300 1SVR550800R9300

Page 229 229 89 89 89 89 89 89 89 89 89 89 89 89 89 89 242 242 242 242 161 161 161 161 161 161 161 161 161 161 242 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 190 190

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX
-- Index Product type

Type CM-MSE CM-MSS.11P CM-MSS.11S CM-MSS.12P CM-MSS.12S CM-MSS.13P CM-MSS.13S CM-MSS.21P CM-MSS.21S CM-MSS.22P CM-MSS.22S CM-MSS.23P CM-MSS.23S CM-MSS.31P CM-MSS.31S CM-MSS.32P CM-MSS.32S CM-MSS.33P CM-MSS.33S CM-MSS.41P CM-MSS.41S CM-MSS.51P CM-MSS.51S CM-PAS.31P CM-PAS.31S CM-PAS.41P CM-PAS.41S CM-PBE CM-PBE CM-PFE CM-PFE.2 CM-PFS.P CM-PFS.S CM-PSS.31P CM-PSS.31S CM-PSS.41P CM-PSS.41S CM-PVE CM-PVE CM-PVS.31P CM-PVS.31S CM-PVS.41P CM-PVS.41S CM-PVS.81P CM-PVS.81S CM-SE-1000 CM-SE-300 CM-SE-600 CM-SFS.21P CM-SFS.21S CM-SFS.22S

Order code 1SVR550801R9300 1SVR740720R1400 1SVR730720R1400 1SVR740700R0100 1SVR730700R0100 1SVR740700R2100 1SVR730700R2100 1SVR740722R1400 1SVR730722R1400 1SVR740700R0200 1SVR730700R0200 1SVR740700R2200 1SVR730700R2200 1SVR740712R1400 1SVR730712R1400 1SVR740712R0200 1SVR730712R0200 1SVR740712R2200 1SVR730712R2200 1SVR740712R1200 1SVR730712R1200 1SVR740712R1300 1SVR730712R1300 1SVR740774R1300 1SVR730774R1300 1SVR740774R3300 1SVR730774R3300 1SVR550881R9400 1SVR550882R9500 1SVR550824R9100 1SVR550826R9100 1SVR740824R9300 1SVR730824R9300 1SVR740784R2300 1SVR730784R2300 1SVR740784R3300 1SVR730784R3300 1SVR550870R9400 1SVR550871R9500 1SVR740794R1300 1SVR730794R1300 1SVR740794R3300 1SVR730794R3300 1SVR740794R2300 1SVR730794R2300 1SVR450056R0200 1SVR450056R0000 1SVR450056R0100 1SVR740760R0400 1SVR730760R0400 1SVR730760R0500

Page 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 190 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 113 242 242 242 87 87 87

Type CM-SRS.11P CM-SRS.11P CM-SRS.11P CM-SRS.11S CM-SRS.11S CM-SRS.11S CM-SRS.12S CM-SRS.12S CM-SRS.12S CM-SRS.21P CM-SRS.21P CM-SRS.21P CM-SRS.21S CM-SRS.21S CM-SRS.21S CM-SRS.22S CM-SRS.22S CM-SRS.22S CM-SRS.M1P CM-SRS.M1S CM-SRS.M2S CM-TCS.11P CM-TCS.11S CM-TCS.12P CM-TCS.12S CM-TCS.13P CM-TCS.13S CM-TCS.21P CM-TCS.21S CM-TCS.22P CM-TCS.22S CM-TCS.23P CM-TCS.23S CM-UFD.M22M CM-UFD.M31 CM-UFD.M31M CM-UFD.M33 CM-UFD.M33M CM-UFD.M34M COV.01 COV.02 COV.11 COV.11 COV.12 CP-B 24/10.0 CP-B 24/20.0 CP-B 24/3.0 CP-B EXT.2 CP-C.1 24/10.0 CP-C.1 24/10.0-C CP-C.1 24/10.0-L

Order code 1SVR740840R0200 1SVR740841R0200 1SVR740841R1200 1SVR730840R0200 1SVR730841R0200 1SVR730841R1200 1SVR730840R0300 1SVR730841R0300 1SVR730841R1300 1SVR740840R0400 1SVR740841R0400 1SVR740841R1400 1SVR730840R0400 1SVR730841R0400 1SVR730841R1400 1SVR730840R0500 1SVR730841R0500 1SVR730841R1500 1SVR740840R0600 1SVR730840R0600 1SVR730840R0700 1SVR740740R0100 1SVR730740R0100 1SVR740740R0200 1SVR730740R0200 1SVR740740R0300 1SVR730740R0300 1SVR740740R9100 1SVR730740R9100 1SVR740740R9200 1SVR730740R9200 1SVR740740R9300 1SVR730740R9300 1SVR560731R3700 1SVR560730R3401 1SVR560731R3701 1SVR560730R3402 1SVR560731R3702 1SVR560731R3703 1SVR430005R0100 1SVR440005R0100 1SVR730005R0100 1SVR730005R0100 1SVR750005R0100 1SVR427060R1000 1SVR427060R2000 1SVR427060R0300 1SVR427065R0000 1SVR360663R1001 1SVR360663R2001 1SVR361663R1001

459
Page 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87
209 209 209 209 209 209 209 209 209 209 209 209 145 145 145 145 145 145 242 242
41 242 242 332 332 332 332 294 294 294

460

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Product type

Type CP-C.1 24/20.0 CP-C.1 24/20.0-C CP-C.1 24/20.0-L CP-C.1 24/5.0 CP-C.1 24/5.0-C CP-C.1 24/5.0-L CP-C.1-A-RU CP-C.1-A-RU-C CP-C.1-A-RU-L CP-D 12/0.83 CP-D 12/2.1 CP-D 24/0.42 CP-D 24/1.3 CP-D 24/2.5 CP-D 24/4.2 CP-D RU CP-E 12/10.0 CP-E 12/2.5 CP-E 24/0.75 CP-E 24/1.25 CP-E 24/10.0 CP-E 24/2.5 CP-E 24/20.0 CP-E 24/5.0 CP-E 48/0.62 CP-E 48/1.25 CP-E 48/10.0 CP-E 48/5.0 CP-E 5/3.0 CP-RUD CP-T 24/10.0 CP-T 24/20.0 CP-T 24/40.0 CP-T 24/5.0 CP-T 48/10.0 CP-T 48/20.0 CP-T 48/5.0 CR-M012AC2L CR-M012AC3L CR-M012AC4L CR-M012DC2 CR-M012DC2L CR-M012DC2LD CR-M012DC3 CR-M012DC3L CR-M012DC3LD CR-M012DC4 CR-M012DC4L CR-M012DC4LD CR-M012DC4LDG CR-M012DC4LDGSS

Order code 1SVR360763R1001 1SVR360763R2001 1SVR361763R1001 1SVR360563R1001 1SVR360563R2001 1SVR361563R1001 1SVR360060R1001 1SVR360060R2001 1SVR361060R1001 1SVR427041R1000 1SVR427043R1200 1SVR427041R0000 1SVR427043R0100 1SVR427044R0200 1SVR427045R0400 1SVR427049R0000 1SVR427035R1000 1SVR427032R1000 1SVR427030R0000 1SVR427031R0000 1SVR427035R0000 1SVR427032R0000 1SVR427036R0000 1SVR427034R0000 1SVR427030R2000 1SVR427031R2000 1SVR427035R2000 1SVR427034R2000 1SVR427033R3000 1SVR423418R9000 1SVR427055R0000 1SVR427056R0000 1SVR427057R0000 1SVR427054R0000 1SVR427055R2000 1SVR427056R2000 1SVR427054R2000 1SVR405611R0300 1SVR405612R0300 1SVR405613R0300 1SVR405611R4000 1SVR405611R4100 1SVR405611R4400 1SVR405612R4000 1SVR405612R4100 1SVR405612R4400 1SVR405613R4000 1SVR405613R4100 1SVR405613R4400 1SVR405618R4400 1SVR405618R4410

Page 294 294 294 294 294 294 342 342 342 318 318 318 318 318 318 342 260 260 260 260 260 260 260 260 260 260 260 260 260 342 280 280 280 280 280 280 280 398 398 398 397 398 399 397 398 399 397 398 399 400 401

Type CR-M012DC4LG CR-M024AC2 CR-M024AC2L CR-M024AC3 CR-M024AC3L CR-M024AC4 CR-M024AC4G CR-M024AC4L CR-M024AC4LG CR-M024AC4LS62CV CR-M024DC2 CR-M024DC2L CR-M024DC2LD CR-M024DC3 CR-M024DC3L CR-M024DC3LD CR-M024DC4 CR-M024DC4G CR-M024DC4GLC62CV CR-M024DC4GSS42V CR-M024DC4L CR-M024DC4LC42 CR-M024DC4LD CR-M024DC4LDG CR-M024DC4LDGSS CR-M024DC4LG CR-M024DC4LGLC22 CR-M024DC4LS42V CR-M024DC4SS42V CR-M048AC2 CR-M048AC2L CR-M048AC3 CR-M048AC3L CR-M048AC4 CR-M048AC4L CR-M048AC4LG CR-M048DC2 CR-M048DC2L CR-M048DC2LD CR-M048DC3 CR-M048DC3L CR-M048DC3LD CR-M048DC4 CR-M048DC4L CR-M048DC4LD CR-M048DC4LG CR-M060AC3 CR-M060DC2 CR-M060DC2L CR-M060DC3 CR-M060DC3L

Order code 1SVR405618R4100 1SVR405611R0000 1SVR405611R0100 1SVR405612R0000 1SVR405612R0100 1SVR405613R0000 1SVR405618R0000 1SVR405613R0100 1SVR405618R0100 1SVR405613R0010 1SVR405611R1000 1SVR405611R1100 1SVR405611R1400 1SVR405612R1000 1SVR405612R1100 1SVR405612R1400 1SVR405613R1000 1SVR405618R1000 1SVR405618R1010 1SVR405618R1011 1SVR405613R1100 1SVR405613R1012 1SVR405614R1100 1SVR405618R1400 1SVR405618R1410 1SVR405618R1100 1SVR405618R1110 1SVR405613R1011 1SVR405613R1010 1SVR405611R5000 1SVR405611R5100 1SVR405612R5000 1SVR405612R5100 1SVR405613R5000 1SVR405613R5100 1SVR405618R5100 1SVR405611R6000 1SVR405611R6100 1SVR405611R6400 1SVR405612R6000 1SVR405612R6100 1SVR405612R6400 1SVR405613R6000 1SVR405613R6100 1SVR405613R6400 1SVR405618R6100 1SVR405612R5200 1SVR405611R4200 1SVR405611R4300 1SVR405612R4200 1SVR405612R4300

Page 400 397 398 397 398 397 399 398 400 401 397 398 399 397 398 399 397 399 401 401 398 401 399 400 401 400 401 401 401 397 398 397 398 397 398 400 397 398 399 397 398 399 397 398 399 400 397 397 398 397 398

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX
-- Index Product type

Type CR-M060DC4 CR-M060DC4L CR-M060DC4LG CR-M110AC2 CR-M110AC2L CR-M110AC3 CR-M110AC3L CR-M110AC4 CR-M110AC4G CR-M110AC4L CR-M110AC4LG CR-M110DC2 CR-M110DC2L CR-M110DC2LD CR-M110DC3 CR-M110DC3L CR-M110DC3LD CR-M110DC4 CR-M110DC4L CR-M110DC4LD CR-M110DC4LG CR-M120AC2 CR-M120AC2L CR-M120AC3 CR-M120AC3L CR-M120AC4 CR-M120AC4L CR-M120AC4LG CR-M125DC2 CR-M125DC2L CR-M125DC2LD CR-M125DC3 CR-M125DC3L CR-M125DC3LD CR-M125DC4 CR-M125DC4L CR-M125DC4LD CR-M125DC4LG CR-M220DC2 CR-M220DC2L CR-M220DC2LD CR-M220DC3 CR-M220DC3L CR-M220DC3LD CR-M220DC4 CR-M220DC4L CR-M220DC4LD CR-M220DC4LG CR-M230AC2 CR-M230AC2L CR-M230AC3

Order code 1SVR405613R4200 1SVR405613R4300 1SVR405618R4300 1SVR405611R7000 1SVR405611R7100 1SVR405612R7000 1SVR405612R7100 1SVR405613R7000 1SVR405618R7000 1SVR405613R7100 1SVR405618R7100 1SVR405611R8000 1SVR405611R8100 1SVR405611R8400 1SVR405612R8000 1SVR405612R8100 1SVR405612R8400 1SVR405613R8000 1SVR405613R8100 1SVR405613R8400 1SVR405618R8100 1SVR405611R2000 1SVR405611R2100 1SVR405612R2000 1SVR405612R2100 1SVR405613R2000 1SVR405613R2100 1SVR405618R2100 1SVR405611R8200 1SVR405611R8300 1SVR405611R8500 1SVR405612R8200 1SVR405612R8300 1SVR405612R8500 1SVR405613R8200 1SVR405613R8300 1SVR405613R8500 1SVR405618R8300 1SVR405611R9000 1SVR405611R9100 1SVR405611R9400 1SVR405612R9000 1SVR405612R9100 1SVR405612R9400 1SVR405613R9000 1SVR405613R9100 1SVR405613R9400 1SVR405618R9100 1SVR405611R3000 1SVR405611R3100 1SVR405612R3000

Page 397 398 400 397 398 397 398 397 399 398 400 397 398 399 397 398 399 397 398 399 400 397 398 397 398 397 398 400 397 398 399 397 398 399 397 398 399 400 397 398 399 397 398 399 397 398 399 400 397 398 397

Type CR-M230AC3L CR-M230AC4 CR-M230AC4G CR-M230AC4GSS92CV CR-M230AC4L CR-M230AC4LC92 CR-M230AC4LG CR-M230AC4LGLC CR-M230AC4LGSS CR-M230AC4LS92CV CR-M230AC4SS92CV CR-M2LC CR-M2LS CR-M2SF CR-M2SS CR-M3LS CR-M3SS CR-M4LC CR-M4LS CR-M4SF CR-M4SS CR-MH CR-MH1 CR-MJ CR-MM CR-MP CR-P/M 22 CR-P/M 42 CR-P/M 42 B CR-P/M 42 BV CR-P/M 42 C CR-P/M 42 CV CR-P/M 42 V CR-P/M 52B CR-P/M 52C CR-P/M 52D CR-P/M 62 CR-P/M 62 C CR-P/M 62 CV CR-P/M 62 D CR-P/M 62 DV CR-P/M 62 E CR-P/M 62 EV CR-P/M 62 V CR-P/M 72 CR-P/M 72 A CR-P/M 82 CR-P/M 92 CR-P/M 92 C CR-P/M 92 CV CR-P/M 92 V

Order code 1SVR405612R3100 1SVR405613R3000 1SVR405618R3000 1SVR405618R3112 1SVR405613R3100 1SVR405613R3012 1SVR405618R3100 1SVR405618R3110 1SVR405618R3111 1SVR405613R3011 1SVR405613R3110 1SVR405651R1200 1SVR405651R1100 1SVR405651R1300 1SVR405651R1000 1SVR405651R2100 1SVR405651R2000 1SVR405651R3200 1SVR405651R3100 1SVR405651R3300 1SVR405651R3000 1SVR405659R1000 1SVR405659R1100 1SVR405658R6000 1SVR405658R1000 1SVR405658R2000 1SVR405651R0000 1SVR405652R0000 1SVR405652R4000 1SVR405652R4100 1SVR405652R9000 1SVR405652R9100 1SVR405652R1000 1SVR405653R0000 1SVR405653R1000 1SVR405653R4000 1SVR405654R0000 1SVR405655R0000 1SVR405655R1000 1SVR405655R4000 1SVR405655R4100 1SVR405654R4000 1SVR405654R4100 1SVR405654R1000 1SVR405656R0000 1SVR405656R1000 1SVR405656R2000 1SVR405654R0100 1SVR405655R0100 1SVR405655R1100 1SVR405654R1100

461
Page 398 397 399 402 398 402 400 402 402 402 402 403 403 403 403 403 403 403 403 403 403 403 403 403 403 403 404 404 404 404 404 404 404 404 404 404 404 405 405 405 405 404 404 404 405 405 405 404 405 405 404

462

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Product type

Type CR-P012AC2 CR-P012DC1 CR-P012DC1SS42V CR-P012DC2 CR-P012DC2SS42V CR-P024AC1 CR-P024AC1SS62CV CR-P024AC2 CR-P024AC2G CR-P024AC2SS62CV CR-P024DC1 CR-P024DC1LC42V CR-P024DC1LC62C CR-P024DC1SS42V CR-P024DC2 CR-P024DC2G CR-P024DC2GLC42V CR-P024DC2GLC62C CR-P024DC2GLC62CV CR-P024DC2LC42 CR-P024DC2LS42 CR-P024DC2LS42V CR-P024DC2SS42V CR-P024MOS1 CR-P024TRI1 CR-P048AC1 CR-P048AC2 CR-P048DC1 CR-P048DC2 CR-P110AC1 CR-P110AC2 CR-P110AC2G CR-P110DC1 CR-P110DC1SS42CV CR-P110DC2 CR-P110DC2SS42CV CR-P120AC1 CR-P120AC1SS92CV CR-P120AC2 CR-P120AC2SS92CV CR-P230AC1 CR-P230AC1LC92CV CR-P230AC1LS CR-P230AC1SS92CV CR-P230AC2 CR-P230AC2G CR-P230AC2GLC92 CR-P230AC2GLC92C CR-P230AC2GLC92CV CR-P230AC2LC92 CR-P230AC2LS92CV

Order code 1SVR405601R0200 1SVR405600R4000 1SVR405600R4010 1SVR405601R4000 1SVR405601R4010 1SVR405600R0000 1SVR405600R0010 1SVR405601R0000 1SVR405606R0000 1SVR405601R0010 1SVR405600R1000 1SVR405600R1011 1SVR405600R1013 1SVR405600R1010 1SVR405601R1000 1SVR405606R1000 1SVR405606R1010 1SVR405606R1013 1SVR405606R1011 1SVR405601R1012 1SVR405601R1013 1SVR405601R1011 1SVR405601R1010 1SVR405610R4060 1SVR405610R4070 1SVR405600R5000 1SVR405601R5000 1SVR405600R6000 1SVR405601R6000 1SVR405600R7000 1SVR405601R7000 1SVR405606R7000 1SVR405600R8000 1SVR405600R8010 1SVR405601R8000 1SVR405601R8010 1SVR405600R2000 1SVR405600R2010 1SVR405601R2000 1SVR405601R2010 1SVR405600R3000 1SVR405600R3010 1SVR405600R3011 1SVR405600R3110 1SVR405601R3000 1SVR405606R3000 1SVR405606R3013 1SVR405606R3012 1SVR405606R3010 1SVR405601R3012 1SVR405601R3011

Page 393 393 395 393 396 393 395 393 393 396 393 395 395 395 393 393 396 396 396 396 396 396 396 393 393 393 393 393 393 393 393 393 393 395 393 396 393 395 393 396 393 395 395 395 393 393 396 396 396 396 396

Type CR-P230AC2SS92CV CR-PH CR-PH1 CR-PJ CR-PLC CR-PLS CR-PLSX CR-PM CR-PSS CR-S005VDC1R CR-S005VDC1RG CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S012VDC1R CR-S012VDC1RG CR-S024VADC1CRGS CR-S024VADC1CRGZ CR-S024VADC1CRS CR-S024VADC1CRZ CR-S024VDC1MOS CR-S024VDC1R CR-S024VDC1RG CR-S024VDC1TRA CR-S024VDC1TRI CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S110VADC1CRGS CR-S110VADC1CRGZ CR-S110VADC1CRS CR-S110VADC1CRZ CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S230VADC1CRGS CR-S230VADC1CRGZ CR-S230VADC1CRS CR-S230VADC1CRZ CR-SJB20-BLACK CR-SJB20-BLUE CR-SJB20-RED CR-SSEP CR-U 21 CR-U 41 CR-U 41B

Order code 1SVR405601R3110 1SVR405659R0000 1SVR405659R0100 1SVR405658R5000 1SVR405650R0200 1SVR405650R0000 1SVR405650R0100 1SVR405658R0000 1SVR405650R1000 1SVR405501R1010 1SVR405501R1020 1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405501R2010 1SVR405501R2020 1SVR405541R3120 1SVR405541R3220 1SVR405541R3110 1SVR405541R3210 1SVR405510R3060 1SVR405501R3010 1SVR405501R3020 1SVR405510R3050 1SVR405510R3070 1SVR405521R5100 1SVR405521R5200 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405521R6100 1SVR405521R6200 1SVR405541R6120 1SVR405541R6220 1SVR405541R6110 1SVR405541R6210 1SVR405521R7100 1SVR405521R7200 1SVR405541R7120 1SVR405541R7220 1SVR405541R7110 1SVR405541R7210 1SVR405598R0900 1SVR405598R0700 1SVR405598R0800 1SVR405599R0000 1SVR405661R0000 1SVR405662R0000 1SVR405662R4000

Page 396 394 394 394 394 394 394 394 394 389 389 390 390 390 390 389 389 389 389 389 389 389 389 389 389 389 390 390 389 389 389 389 390 390 389 389 389 389 390 390 389 389 389 389 390 390 390 390 408 408 408

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX
-- Index Product type

Type CR-U 41BV CR-U 41C CR-U 41CV CR-U 41V CR-U 51B CR-U 51C CR-U 51D CR-U 61 CR-U 61C CR-U 61CV CR-U 61D CR-U 61DV CR-U 61E CR-U 61EV CR-U 61V CR-U 71 CR-U 71A CR-U 81 CR-U 91 CR-U 91C CR-U 91CV CR-U 91V CR-U T CR-U012AC2L CR-U012AC3L CR-U012DC2 CR-U012DC2L CR-U012DC2LD CR-U012DC3 CR-U012DC3L CR-U012DC3LD CR-U024AC2 CR-U024AC2L CR-U024AC3 CR-U024AC3L CR-U024DC2 CR-U024DC2L CR-U024DC2LD CR-U024DC3 CR-U024DC3L CR-U024DC3LD CR-U048AC2 CR-U048AC2L CR-U048AC3 CR-U048AC3L CR-U048DC2 CR-U048DC2L CR-U048DC2LD CR-U048DC3 CR-U048DC3L CR-U048DC3LD

Order code 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405662R1000 1SVR405663R0000 1SVR405663R1000 1SVR405663R4000 1SVR405664R0000 1SVR405665R0000 1SVR405665R1000 1SVR405665R4000 1SVR405665R4100 1SVR405664R4000 1SVR405664R4100 1SVR405664R1000 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 1SVR405664R0100 1SVR405665R0100 1SVR405665R1100 1SVR405664R1100 1SVR405667R0000 1SVR405621R0300 1SVR405622R0300 1SVR405621R4000 1SVR405621R4100 1SVR405621R4400 1SVR405622R4000 1SVR405622R4100 1SVR405622R4400 1SVR405621R0000 1SVR405621R0100 1SVR405622R0000 1SVR405622R0100 1SVR405621R1000 1SVR405621R1100 1SVR405621R1400 1SVR405622R1000 1SVR405622R1100 1SVR405623R1100 1SVR405621R5000 1SVR405621R5100 1SVR405622R5000 1SVR405622R5100 1SVR405621R6000 1SVR405621R6100 1SVR405621R6400 1SVR405622R6000 1SVR405622R6100 1SVR405622R6400

Page 408 408 408 408 408 408 408 408 409 409 409 409 408 408 408 409 409 409 408 409 409 408 409 406 407 406 406 407 406 407 407 406 406 406 407 406 406 407 406 407 407 406 406 406 407 406 406 407 406 407 407

Type CR-U060AC3 CR-U110AC2 CR-U110AC2L CR-U110AC3 CR-U110AC3L CR-U110DC2 CR-U110DC2L CR-U110DC2LD CR-U110DC3 CR-U110DC3L CR-U110DC3LD CR-U120AC2 CR-U120AC2L CR-U120AC3 CR-U120AC3L CR-U125DC3 CR-U220DC2 CR-U220DC2L CR-U220DC3 CR-U220DC3L CR-U230AC2 CR-U230AC2L CR-U230AC3 CR-U230AC3L CR-U2S CR-U2SM CR-U3E CR-U3S CR-U3SM CR-UH CT- MXS.22S CT-AHC.12 CT-AHC.22 CT-AHD.12 CT-AHD.22 CT-AHS.22P CT-AHS.22S CT-APS.12P CT-APS.12S CT-APS.21P CT-APS.21S CT-APS.22P CT-APS.22S CT-ARC.12 CT-ARS.11P CT-ARS.11S CT-ARS.21P CT-ARS.21S CT-EBC.12 CT-EBD.12 CT-ERC.12

Order code 1SVR405622R5200 1SVR405621R7000 1SVR405621R7100 1SVR405622R7000 1SVR405622R7100 1SVR405621R8000 1SVR405621R8100 1SVR405621R8400 1SVR405622R8000 1SVR405622R8100 1SVR405622R8400 1SVR405621R2000 1SVR405621R2100 1SVR405622R2000 1SVR405622R2100 1SVR405622R8200 1SVR405621R9000 1SVR405621R9100 1SVR405622R9000 1SVR405622R9100 1SVR405621R3000 1SVR405621R3100 1SVR405622R3000 1SVR405622R3100 1SVR405670R0000 1SVR405670R1100 1SVR405660R0100 1SVR405660R0000 1SVR405660R1100 1SVR405669R0000 1SVR730030R3300 1SVR508110R0000 1SVR508110R0100 1SVR500110R0000 1SVR500110R0100 1SVR740110R3300 1SVR730110R3300 1SVR740180R3100 1SVR730180R3100 1SVR740180R0300 1SVR730180R0300 1SVR740180R3300 1SVR730180R3300 1SVR508120R0000 1SVR740120R3100 1SVR730120R3100 1SVR740120R3300 1SVR730120R3300 1SVR508150R0000 1SVR500150R0000 1SVR508100R0000

463
Page 406 406 406 406 407 406 406 407 406 407 407 406 406 406 407 406 406 406 406 407 406 406 406 407 407 407 407 407 407 407 39 25 25 57 57 40 40 40 40 40 40 40 40 25 40 40 40 40 25 57 25

464

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Product type

Type CT-ERC.22 CT-ERD.12 CT-ERD.22 CT-ERS.12P CT-ERS.12S CT-ERS.21P CT-ERS.21S CT-ERS.22P CT-ERS.22S CT-MBS.22P CT-MBS.22S CT-MFC.12 CT-MFC.21 CT-MFD.12 CT-MFD.21 CT-MFS.21P CT-MFS.21S CT-MKC.31 CT-MVS.12P CT-MVS.12S CT-MVS.21P CT-MVS.21S CT-MVS.22P CT-MVS.22S CT-MVS.23P CT-MVS.23S CT-MXS.22P CT-SAC.22 CT-SAD.22 CT-SDC.22 CT-SDD.22 CT-SDS.22P CT-SDS.22S CT-SDS.23P CT-SDS.23S CT-TGC.12 CT-TGC.22 CT-TGD.12 CT-TGD.22 CT-VWC.12 CT-VWD.12 CT-WBS.22P CT-WBS.22S EPD24-TB-101-0.5A EPD24-TB-101-10A EPD24-TB-101-12A EPD24-TB-101-1A EPD24-TB-101-2A EPD24-TB-101-3A EPD24-TB-101-4A EPD24-TB-101-6A

Order code 1SVR508100R0100 1SVR500100R0000 1SVR500100R0100 1SVR740100R3100 1SVR730100R3100 1SVR740100R0300 1SVR730100R0300 1SVR740100R3300 1SVR730100R3300 1SVR740010R3200 1SVR730010R3200 1SVR508020R0000 1SVR508020R1100 1SVR500020R0000 1SVR500020R1100 1SVR740010R0200 1SVR730010R0200 1SVR508010R1300 1SVR740020R3100 1SVR730020R3100 1SVR740020R0200 1SVR730020R0200 1SVR740020R3300 1SVR730020R3300 1SVR740021R2300 1SVR730021R2300 1SVR740030R3300 1SVR508210R0100 1SVR500210R0100 1SVR508211R0100 1SVR500211R0100 1SVR740210R3300 1SVR730210R3300 1SVR740211R2300 1SVR730211R2300 1SVR508160R0000 1SVR508160R0100 1SVR500160R0000 1SVR500160R0100 1SVR508130R0000 1SVR500130R0000 1SVR740040R3300 1SVR730040R3300 2CDE601101R2905 2CDE601101R2010 2CDE601101R2012 2CDE601101R2001 2CDE601101R2002 2CDE601101R2003 2CDE601101R2004 2CDE601101R2006

Page 25 57 57 40 40 40 40 40 40 39 39 25 25 57 57 39 39 25 39 39 39 39 39 39 39 39 39 25 57 25 57 40 40 40 40 25 25 57 57 25 57 39 39
352 352 352 352 352 352 352 352

Type EPD24-TB-101-8A EPD-BB500 EPD-SB21 K A1- 8029 K A1- 8030 MA16-1060 MAR.01 MAR.01 MAR.02 MAR.12 MAR.12 MT-150B MT-250B MT-350B OBIC0100-115-230 OBIC0100-24VDC OBIC0100-48-60VUC OBIC0100-5-12VDC OBOA1000-115VUC OBOA1000-230VUC OBOA1000-24VDC OBOA2000-24VDC OBOC2000-115VUC OBOC2000-230VUC OBOC2000-24VDC OBOC2000-24VUC OBOC2000-48-60VUC OBOC2000-5-12VDC OBOC5000-115VUC OBOC5000-24VDC OBRIC0100-115-230 OBRIC0100-24VDC OBRIC0100-48-60VUC OBRIC0100-5-12VDC OBROA1000-24VDC OBROA2000-24VDC OBROC2000-230VUC OBROC2000-24VDC OBROC2000-24VUC OBROC2000-48-60VUC OBROC2000-5-12VDC OBROC5000-230VUC OBROC5000-24VDC RB101R-24VUC RB111-115VUC RB111-230VUC RB111-24VUC RB111R-24VUC RB121-115VUC RB121-12VDC RB121-230VUC

Order code 2CDE601101R2008 2CDE605100R0500 2CDE605200R0021 1SFA616920R8029 1SFA616920R8030 1SFA611940R1060 1SVR366017R0100 1SVR366017R0100 1SVR430043R0000 1SVR730006R0000 1SVR730006R0000 1SFA611410R1506 1SFA611410R2506 1SFA611410R3506 1SNA645022R2700 1SNA645021R2600 1SNA645049R1200 1SNA645047R0000 1SNA645062R0700 1SNA645028R0500 1SNA645027R2400 1SNA645029R0600 1SNA645054R0700 1SNA645026R2300 1SNA645051R0400 1SNA645025R2200 1SNA645053R0600 1SNA645050R1700 1SNA645058R1300 1SNA645024R2100 1SNA645522R2100 1SNA645521R2000 1SNA645549R1400 1SNA645547R0200 1SNA645527R2600 1SNA645529R0000 1SNA645526R2500 1SNA645551R0600 1SNA645525R2400 1SNA645553R0000 1SNA645550R1100 1SNA645559R1600 1SNA645524R2300 1SNA645019R0400 1SNA645016R2100 1SNA645017R2200 1SNA645014R2700 1SNA645018R0300 1SNA645003R0500 1SNA645073R0000 1SNA645004R0400

Page 352 352 352 41 41 41 41 242 242 41 242 41 41 41 451 451 451 451 451 451 451 452 451 451 451 451 451 451 451 451 451 451 451 451 451 452 451 451 451 451 451 451 451 442 442 442 442 442 442 442 442

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

465

-- Index Product type

Type RB121-24VDC RB121-24VUC RB121-48-60VUC RB121-60-230VUC RB121G-115VUC RB121G-12VDC RB121G-230VUC RB121G-24VDC RB121G-24VUC RB121G-48-60VUC RB121P-12VDC RB121P-5VDC RB121PG-5VDC RB121R-115VUC RB121R-230VUC RB122G-115VUC RB122G-230VUC RB122G-24VUC RB122G-48-60VUC RB-JB10 RB-JB20 RBR101R-24VUC RBR111-24VUC RBR111R-24VUC RBR121-115VUC RBR121-230VUC RBR121-24VDC RBR121-24VUC RBR121-48-60VUC RBR121-60-230VUC RBR121G-115VUC RBR121G-230VUC RBR121G-24VDC RBR121G-24VUC RBR121G-48-60VUC RBR121P-12VDC RBR121P-5VDC RBR121R-230VUC RBR122G-115VUC RBR122G-230VUC RBR122G-24VUC RBR122G-48-60VUC SC612 SK 615 562-87 SK 615 562-88

Order code 1SNA645071R0000 1SNA645001R0300 1SNA645002R0400 1SNA645020R0100 1SNA645007R0100 1SNA645075R0000 1SNA645008R1200 1SNA645072R0000 1SNA645005R0700 1SNA645006R0000 1SNA645035R2400 1SNA645034R2300 1SNA645036R2500 1SNA645046R0700 1SNA645011R2400 1SNA645041R0200 1SNA645013R2600 1SNA645012R2500 1SNA645040R1500 1SVR406570R0000 1SVR406580R0000 1SNA645519R0600 1SNA645514R2100 1SNA645518R0500 1SNA645503R0700 1SNA645504R0000 1SNA645571R0000 1SNA645501R0500 1SNA645502R0600 1SNA645520R0300 1SNA645507R0300 1SNA645508R1400 1SNA645572R0000 1SNA645505R0100 1SNA645506R0200 1SNA645535R2600 1SNA645534R2500 1SNA645511R2600 1SNA645541R0400 1SNA645513R2000 1SNA645512R2700 1SNA645540R1700 1SNA290474R0200 GJD6155620R0087 GJD6155620R0088

Page 442 442 442 443 443 443 443 443 443 443 442 442 443 443 443 443 443 443 443 452 452 442 442 442 442 442 442 442 442 443 443 443 443 443 443 442 442 443 443 443 443 443 443 41 41

466

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Order code

Type MT-150B MT-250B MT-350B MA16-1060 K A1- 8029 K A1- 8030 SC612 RB121-24VUC RB121-48-60VUC RB121-115VUC RB121-230VUC RB121G-24VUC RB121G-48-60VUC RB121G-115VUC RB121G-230VUC RB121R-230VUC RB122G-24VUC RB122G-230VUC RB111-24VUC RB111-115VUC RB111-230VUC RB111R-24VUC RB101R-24VUC RB121-60-230VUC OBIC0100-24VDC OBIC0100-115-230 OBOC5000-24VDC OBOC2000-24VUC OBOC2000-230VUC OBOA1000-24VDC OBOA1000-230VUC OBOA2000-24VDC RB121P-5VDC RB121P-12VDC RB121PG-5VDC RB122G-48-60VUC RB122G-115VUC RB121R-115VUC OBIC0100-5-12VDC OBIC0100-48-60VUC OBOC2000-5-12VDC OBOC2000-24VDC OBOC2000-48-60VUC OBOC2000-115VUC OBOC5000-115VUC OBOA1000-115VUC RB121-24VDC RB121G-24VDC RB121-12VDC RB121G-12VDC RBR121-24VUC

Order code 1SFA611410R1506 1SFA611410R2506 1SFA611410R3506 1SFA611940R1060 1SFA616920R8029 1SFA616920R8030 1SNA290474R0200 1SNA645001R0300 1SNA645002R0400 1SNA645003R0500 1SNA645004R0400 1SNA645005R0700 1SNA645006R0000 1SNA645007R0100 1SNA645008R1200 1SNA645011R2400 1SNA645012R2500 1SNA645013R2600 1SNA645014R2700 1SNA645016R2100 1SNA645017R2200 1SNA645018R0300 1SNA645019R0400 1SNA645020R0100 1SNA645021R2600 1SNA645022R2700 1SNA645024R2100 1SNA645025R2200 1SNA645026R2300 1SNA645027R2400 1SNA645028R0500 1SNA645029R0600 1SNA645034R2300 1SNA645035R2400 1SNA645036R2500 1SNA645040R1500 1SNA645041R0200 1SNA645046R0700 1SNA645047R0000 1SNA645049R1200 1SNA645050R1700 1SNA645051R0400 1SNA645053R0600 1SNA645054R0700 1SNA645058R1300 1SNA645062R0700 1SNA645071R0000 1SNA645072R0000 1SNA645073R0000 1SNA645075R0000 1SNA645501R0500

Page 41 41 41 41 41 41
443 442 442 442 442 443 443 443 443 443 443 443 442 442 442 442 442 443 451 451 451 451 451 451 451 452 442 442 443 443 443 443 451 451 451 451 451 451 451 451 442 443 442 443 442

Type RBR121-48-60VUC RBR121-115VUC RBR121-230VUC RBR121G-24VUC RBR121G-48-60VUC RBR121G-115VUC RBR121G-230VUC RBR121R-230VUC RBR122G-24VUC RBR122G-230VUC RBR111-24VUC RBR111R-24VUC RBR101R-24VUC RBR121-60-230VUC OBRIC0100-24VDC OBRIC0100-115-230 OBROC5000-24VDC OBROC2000-24VUC OBROC2000-230VUC OBROA1000-24VDC OBROA2000-24VDC RBR121P-5VDC RBR121P-12VDC RBR122G-48-60VUC RBR122G-115VUC OBRIC0100-5-12VDC OBRIC0100-48-60VUC OBROC2000-5-12VDC OBROC2000-24VDC OBROC2000-48-60VUC OBROC5000-230VUC RBR121-24VDC RBR121G-24VDC CP-C.1-A-RU CP-C.1-A-RU-C CP-C.1 24/5.0 CP-C.1 24/5.0-C CP-C.1 24/10.0 CP-C.1 24/10.0-C CP-C.1 24/20.0 CP-C.1 24/20.0-C CP-C.1-A-RU-L CP-C.1 24/5.0-L CP-C.1 24/10.0-L CP-C.1 24/20.0-L MAR.01 MAR.01 CM-HE CM-HC CM-HCT CR-S005VDC1R

Order code 1SNA645502R0600 1SNA645503R0700 1SNA645504R0000 1SNA645505R0100 1SNA645506R0200 1SNA645507R0300 1SNA645508R1400 1SNA645511R2600 1SNA645512R2700 1SNA645513R2000 1SNA645514R2100 1SNA645518R0500 1SNA645519R0600 1SNA645520R0300 1SNA645521R2000 1SNA645522R2100 1SNA645524R2300 1SNA645525R2400 1SNA645526R2500 1SNA645527R2600 1SNA645529R0000 1SNA645534R2500 1SNA645535R2600 1SNA645540R1700 1SNA645541R0400 1SNA645547R0200 1SNA645549R1400 1SNA645550R1100 1SNA645551R0600 1SNA645553R0000 1SNA645559R1600 1SNA645571R0000 1SNA645572R0000 1SVR360060R1001 1SVR360060R2001 1SVR360563R1001 1SVR360563R2001 1SVR360663R1001 1SVR360663R2001 1SVR360763R1001 1SVR360763R2001 1SVR361060R1001 1SVR361563R1001 1SVR361663R1001 1SVR361763R1001 1SVR366017R0100 1SVR366017R0100 1SVR402902R0000 1SVR402902R1000 1SVR402902R2000 1SVR405501R1010

Page 442 442 442 443 443 443 443 443 443 443 442 442 442 443 451 451 451 451 451 451 452 442 442 443 443 451 451 451 451 451 451 442 443 342 342 294 294 294 294 294 294 342 294 294 294 41 242 242 242 242 389

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX
-- Index Order code

Type CR-S005VDC1RG CR-S012VDC1R CR-S012VDC1RG CR-S024VDC1R CR-S024VDC1RG CR-S048VDC1R CR-S048VDC1RG CR-S060VDC1R CR-S060VDC1RG CR-S024VDC1TRA CR-S024VDC1MOS CR-S024VDC1TRI CR-S006/024VDC1SS CR-S006/024VDC1SZ CR-S012/024VADC1SS CR-S012/024VADC1SZ CR-S048/060VADC1SS CR-S048/060VADC1SZ CR-S110/125VADC1SS CR-S110/125VADC1SZ CR-S220/240VADC1SS CR-S220/240VADC1SZ CR-S024VADC1CRS CR-S024VADC1CRGS CR-S024VADC1CRZ CR-S024VADC1CRGZ CR-S110VADC1CRS CR-S110VADC1CRGS CR-S110VADC1CRZ CR-S110VADC1CRGZ CR-S230VADC1CRS CR-S230VADC1CRGS CR-S230VADC1CRZ CR-S230VADC1CRGZ CR-SJB20-BLUE CR-SJB20-RED CR-SJB20-BLACK CR-SSEP CR-P024AC1 CR-P024AC1SS62CV CR-P024DC1 CR-P024DC1SS42V CR-P024DC1LC42V CR-P024DC1LC62C CR-P120AC1 CR-P120AC1SS92CV CR-P230AC1 CR-P230AC1LC92CV CR-P230AC1LS CR-P230AC1SS92CV CR-P012DC1

Order code 1SVR405501R1020 1SVR405501R2010 1SVR405501R2020 1SVR405501R3010 1SVR405501R3020 1SVR405501R4010 1SVR405501R4020 1SVR405501R5010 1SVR405501R5020 1SVR405510R3050 1SVR405510R3060 1SVR405510R3070 1SVR405521R1100 1SVR405521R1200 1SVR405521R3100 1SVR405521R3200 1SVR405521R5100 1SVR405521R5200 1SVR405521R6100 1SVR405521R6200 1SVR405521R7100 1SVR405521R7200 1SVR405541R3110 1SVR405541R3120 1SVR405541R3210 1SVR405541R3220 1SVR405541R6110 1SVR405541R6120 1SVR405541R6210 1SVR405541R6220 1SVR405541R7110 1SVR405541R7120 1SVR405541R7210 1SVR405541R7220 1SVR405598R0700 1SVR405598R0800 1SVR405598R0900 1SVR405599R0000 1SVR405600R0000 1SVR405600R0010 1SVR405600R1000 1SVR405600R1010 1SVR405600R1011 1SVR405600R1013 1SVR405600R2000 1SVR405600R2010 1SVR405600R3000 1SVR405600R3010 1SVR405600R3011 1SVR405600R3110 1SVR405600R4000

Page 389 389 389 389 389 389 389 389 389 389 389 389 390 390 390 390 390 390 390 390 390 390 389 389 389 389 389 389 389 389 389 389 389 389 390 390 390 390 393 395 393 395 395 395 393 395 393 395 395 395 393

Type CR-P012DC1SS42V CR-P048AC1 CR-P048DC1 CR-P110AC1 CR-P110DC1 CR-P110DC1SS42CV CR-P024AC2 CR-P024AC2SS62CV CR-P012AC2 CR-P024DC2 CR-P024DC2SS42V CR-P024DC2LS42V CR-P024DC2LC42 CR-P024DC2LS42 CR-P120AC2 CR-P120AC2SS92CV CR-P230AC2 CR-P230AC2LS92CV CR-P230AC2LC92 CR-P230AC2SS92CV CR-P012DC2 CR-P012DC2SS42V CR-P048AC2 CR-P048DC2 CR-P110AC2 CR-P110DC2 CR-P110DC2SS42CV CR-P024AC2G CR-P024DC2G CR-P024DC2GLC42V CR-P024DC2GLC62CV CR-P024DC2GLC62C CR-P230AC2G CR-P230AC2GLC92CV CR-P230AC2GLC92C CR-P230AC2GLC92 CR-P110AC2G CR-P024MOS1 CR-P024TRI1 CR-M024AC2 CR-M024AC2L CR-M012AC2L CR-M024DC2 CR-M024DC2L CR-M024DC2LD CR-M120AC2 CR-M120AC2L CR-M230AC2 CR-M230AC2L CR-M012DC2 CR-M012DC2L

Order code 1SVR405600R4010 1SVR405600R5000 1SVR405600R6000 1SVR405600R7000 1SVR405600R8000 1SVR405600R8010 1SVR405601R0000 1SVR405601R0010 1SVR405601R0200 1SVR405601R1000 1SVR405601R1010 1SVR405601R1011 1SVR405601R1012 1SVR405601R1013 1SVR405601R2000 1SVR405601R2010 1SVR405601R3000 1SVR405601R3011 1SVR405601R3012 1SVR405601R3110 1SVR405601R4000 1SVR405601R4010 1SVR405601R5000 1SVR405601R6000 1SVR405601R7000 1SVR405601R8000 1SVR405601R8010 1SVR405606R0000 1SVR405606R1000 1SVR405606R1010 1SVR405606R1011 1SVR405606R1013 1SVR405606R3000 1SVR405606R3010 1SVR405606R3012 1SVR405606R3013 1SVR405606R7000 1SVR405610R4060 1SVR405610R4070 1SVR405611R0000 1SVR405611R0100 1SVR405611R0300 1SVR405611R1000 1SVR405611R1100 1SVR405611R1400 1SVR405611R2000 1SVR405611R2100 1SVR405611R3000 1SVR405611R3100 1SVR405611R4000 1SVR405611R4100

467
Page 395 393 393 393 393 395 393 396 393 393 396 396 396 396 393 396 393 396 396 396 393 396 393 393 393 393 396 393 393 396 396 396 393 396 396 396 393 393 393 397 398 398 397 398 399 397 398 397 398 397 398

468

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Order code

Type CR-M060DC2 CR-M060DC2L CR-M012DC2LD CR-M048AC2 CR-M048AC2L CR-M048DC2 CR-M048DC2L CR-M048DC2LD CR-M110AC2 CR-M110AC2L CR-M110DC2 CR-M110DC2L CR-M125DC2 CR-M125DC2L CR-M110DC2LD CR-M125DC2LD CR-M220DC2 CR-M220DC2L CR-M220DC2LD CR-M024AC3 CR-M024AC3L CR-M012AC3L CR-M024DC3 CR-M024DC3L CR-M024DC3LD CR-M120AC3 CR-M120AC3L CR-M230AC3 CR-M230AC3L CR-M012DC3 CR-M012DC3L CR-M060DC3 CR-M060DC3L CR-M012DC3LD CR-M048AC3 CR-M048AC3L CR-M060AC3 CR-M048DC3 CR-M048DC3L CR-M048DC3LD CR-M110AC3 CR-M110AC3L CR-M110DC3 CR-M110DC3L CR-M125DC3 CR-M125DC3L CR-M110DC3LD CR-M125DC3LD CR-M220DC3 CR-M220DC3L CR-M220DC3LD

Order code 1SVR405611R4200 1SVR405611R4300 1SVR405611R4400 1SVR405611R5000 1SVR405611R5100 1SVR405611R6000 1SVR405611R6100 1SVR405611R6400 1SVR405611R7000 1SVR405611R7100 1SVR405611R8000 1SVR405611R8100 1SVR405611R8200 1SVR405611R8300 1SVR405611R8400 1SVR405611R8500 1SVR405611R9000 1SVR405611R9100 1SVR405611R9400 1SVR405612R0000 1SVR405612R0100 1SVR405612R0300 1SVR405612R1000 1SVR405612R1100 1SVR405612R1400 1SVR405612R2000 1SVR405612R2100 1SVR405612R3000 1SVR405612R3100 1SVR405612R4000 1SVR405612R4100 1SVR405612R4200 1SVR405612R4300 1SVR405612R4400 1SVR405612R5000 1SVR405612R5100 1SVR405612R5200 1SVR405612R6000 1SVR405612R6100 1SVR405612R6400 1SVR405612R7000 1SVR405612R7100 1SVR405612R8000 1SVR405612R8100 1SVR405612R8200 1SVR405612R8300 1SVR405612R8400 1SVR405612R8500 1SVR405612R9000 1SVR405612R9100 1SVR405612R9400

Page 397 398 399 397 398 397 398 399 397 398 397 398 397 398 399 399 397 398 399 397 398 398 397 398 399 397 398 397 398 397 398 397 398 399 397 398 397 397 398 399 397 398 397 398 397 398 399 399 397 398 399

Type CR-M024AC4 CR-M024AC4LS62CV CR-M024AC4L CR-M012AC4L CR-M024DC4 CR-M024DC4SS42V CR-M024DC4LS42V CR-M024DC4LC42 CR-M024DC4L CR-M120AC4 CR-M120AC4L CR-M230AC4 CR-M230AC4LS92CV CR-M230AC4LC92 CR-M230AC4L CR-M230AC4SS92CV CR-M012DC4 CR-M012DC4L CR-M060DC4 CR-M060DC4L CR-M012DC4LD CR-M048AC4 CR-M048AC4L CR-M048DC4 CR-M048DC4L CR-M048DC4LD CR-M110AC4 CR-M110AC4L CR-M110DC4 CR-M110DC4L CR-M125DC4 CR-M125DC4L CR-M110DC4LD CR-M125DC4LD CR-M220DC4 CR-M220DC4L CR-M220DC4LD CR-M024DC4LD CR-M024AC4G CR-M024AC4LG CR-M024DC4G CR-M024DC4GLC62CV CR-M024DC4GSS42V CR-M024DC4LG CR-M024DC4LGLC22 CR-M024DC4LDG CR-M024DC4LDGSS CR-M120AC4LG CR-M230AC4G CR-M230AC4LG CR-M230AC4LGLC

Order code 1SVR405613R0000 1SVR405613R0010 1SVR405613R0100 1SVR405613R0300 1SVR405613R1000 1SVR405613R1010 1SVR405613R1011 1SVR405613R1012 1SVR405613R1100 1SVR405613R2000 1SVR405613R2100 1SVR405613R3000 1SVR405613R3011 1SVR405613R3012 1SVR405613R3100 1SVR405613R3110 1SVR405613R4000 1SVR405613R4100 1SVR405613R4200 1SVR405613R4300 1SVR405613R4400 1SVR405613R5000 1SVR405613R5100 1SVR405613R6000 1SVR405613R6100 1SVR405613R6400 1SVR405613R7000 1SVR405613R7100 1SVR405613R8000 1SVR405613R8100 1SVR405613R8200 1SVR405613R8300 1SVR405613R8400 1SVR405613R8500 1SVR405613R9000 1SVR405613R9100 1SVR405613R9400 1SVR405614R1100 1SVR405618R0000 1SVR405618R0100 1SVR405618R1000 1SVR405618R1010 1SVR405618R1011 1SVR405618R1100 1SVR405618R1110 1SVR405618R1400 1SVR405618R1410 1SVR405618R2100 1SVR405618R3000 1SVR405618R3100 1SVR405618R3110

Page 397 401 398 398 397 401 401 401 398 397 398 397 402 402 398 402 397 398 397 398 399 397 398 397 398 399 397 398 397 398 397 398 399 399 397 398 399 399 399 400 399 401 401 400 401 400 401 400 399 400 402

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX
-- Index Order code

Type CR-M230AC4LGSS CR-M230AC4GSS92CV CR-M012DC4LG CR-M060DC4LG CR-M012DC4LDG CR-M012DC4LDGSS CR-M048AC4LG CR-M048DC4LG CR-M110AC4G CR-M110AC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG CR-U024AC2 CR-U024AC2L CR-U012AC2L CR-U024DC2 CR-U024DC2L CR-U024DC2LD CR-U120AC2 CR-U120AC2L CR-U230AC2 CR-U230AC2L CR-U012DC2 CR-U012DC2L CR-U012DC2LD CR-U048AC2 CR-U048AC2L CR-U048DC2 CR-U048DC2L CR-U048DC2LD CR-U110AC2 CR-U110AC2L CR-U110DC2 CR-U110DC2L CR-U110DC2LD CR-U220DC2 CR-U220DC2L CR-U024AC3 CR-U024AC3L CR-U012AC3L CR-U024DC3 CR-U024DC3L CR-U120AC3 CR-U120AC3L CR-U230AC3 CR-U230AC3L CR-U012DC3 CR-U012DC3L CR-U012DC3LD CR-U048AC3

Order code 1SVR405618R3111 1SVR405618R3112 1SVR405618R4100 1SVR405618R4300 1SVR405618R4400 1SVR405618R4410 1SVR405618R5100 1SVR405618R6100 1SVR405618R7000 1SVR405618R7100 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 1SVR405621R0000 1SVR405621R0100 1SVR405621R0300 1SVR405621R1000 1SVR405621R1100 1SVR405621R1400 1SVR405621R2000 1SVR405621R2100 1SVR405621R3000 1SVR405621R3100 1SVR405621R4000 1SVR405621R4100 1SVR405621R4400 1SVR405621R5000 1SVR405621R5100 1SVR405621R6000 1SVR405621R6100 1SVR405621R6400 1SVR405621R7000 1SVR405621R7100 1SVR405621R8000 1SVR405621R8100 1SVR405621R8400 1SVR405621R9000 1SVR405621R9100 1SVR405622R0000 1SVR405622R0100 1SVR405622R0300 1SVR405622R1000 1SVR405622R1100 1SVR405622R2000 1SVR405622R2100 1SVR405622R3000 1SVR405622R3100 1SVR405622R4000 1SVR405622R4100 1SVR405622R4400 1SVR405622R5000

Page 402 402 400 400 400 401 400 400 399 400 400 400 400 406 406 406 406 406 407 406 406 406 406 406 406 407 406 406 406 406 407 406 406 406 406 407 406 406 406 407 407 406 407 406 407 406 407 406 407 407 406

Type CR-U048AC3L CR-U060AC3 CR-U048DC3 CR-U048DC3L CR-U048DC3LD CR-U110AC3 CR-U110AC3L CR-U110DC3 CR-U110DC3L CR-U125DC3 CR-U110DC3LD CR-U220DC3 CR-U220DC3L CR-U024DC3LD CR-PLS CR-PLSX CR-PLC CR-PSS CR-P/M 22 CR-M2SS CR-M2LS CR-M2LC CR-M2SF CR-M3SS CR-M3LS CR-M4SS CR-M4LS CR-M4LC CR-M4SF CR-P/M 42 CR-P/M 42 V CR-P/M 42 B CR-P/M 42 BV CR-P/M 42 C CR-P/M 42 CV CR-P/M 52B CR-P/M 52C CR-P/M 52D CR-P/M 62 CR-P/M 92 CR-P/M 62 V CR-P/M 92 V CR-P/M 62 E CR-P/M 62 EV CR-P/M 62 C CR-P/M 92 C CR-P/M 62 CV CR-P/M 92 CV CR-P/M 62 D CR-P/M 62 DV CR-P/M 72

Order code 1SVR405622R5100 1SVR405622R5200 1SVR405622R6000 1SVR405622R6100 1SVR405622R6400 1SVR405622R7000 1SVR405622R7100 1SVR405622R8000 1SVR405622R8100 1SVR405622R8200 1SVR405622R8400 1SVR405622R9000 1SVR405622R9100 1SVR405623R1100 1SVR405650R0000 1SVR405650R0100 1SVR405650R0200 1SVR405650R1000 1SVR405651R0000 1SVR405651R1000 1SVR405651R1100 1SVR405651R1200 1SVR405651R1300 1SVR405651R2000 1SVR405651R2100 1SVR405651R3000 1SVR405651R3100 1SVR405651R3200 1SVR405651R3300 1SVR405652R0000 1SVR405652R1000 1SVR405652R4000 1SVR405652R4100 1SVR405652R9000 1SVR405652R9100 1SVR405653R0000 1SVR405653R1000 1SVR405653R4000 1SVR405654R0000 1SVR405654R0100 1SVR405654R1000 1SVR405654R1100 1SVR405654R4000 1SVR405654R4100 1SVR405655R0000 1SVR405655R0100 1SVR405655R1000 1SVR405655R1100 1SVR405655R4000 1SVR405655R4100 1SVR405656R0000

469
Page 407 406 406 407 407 406 407 406 407 406 407 406 407 407 394 394 394 394 404 403 403 403 403 403 403 403 403 403 403 404 404 404 404 404 404 404 404 404 404 404 404 404 404 404 405 405 405 405 405 405 405

470

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Order code

Type CR-P/M 72 A CR-P/M 82 CR-PM CR-MM CR-MP CR-PJ CR-MJ CR-PH CR-PH1 CR-MH CR-MH1 CR-U3S CR-U3E CR-U3SM CR-U 21 CR-U 41 CR-U 41V CR-U 41B CR-U 41BV CR-U 41C CR-U 41CV CR-U 51B CR-U 51C CR-U 51D CR-U 61 CR-U 91 CR-U 61V CR-U 91V CR-U 61E CR-U 61EV CR-U 61C CR-U 91C CR-U 61CV CR-U 91CV CR-U 61D CR-U 61DV CR-U 71 CR-U 71A CR-U 81 CR-U T CR-UH CR-U2S CR-U2SM RB-JB10 RB-JB20 CP-RUD CP-E 24/0.75 CP-E 48/0.62 CP-E 24/1.25 CP-E 48/1.25 CP-E 24/2.5

Order code 1SVR405656R1000 1SVR405656R2000 1SVR405658R0000 1SVR405658R1000 1SVR405658R2000 1SVR405658R5000 1SVR405658R6000 1SVR405659R0000 1SVR405659R0100 1SVR405659R1000 1SVR405659R1100 1SVR405660R0000 1SVR405660R0100 1SVR405660R1100 1SVR405661R0000 1SVR405662R0000 1SVR405662R1000 1SVR405662R4000 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405663R0000 1SVR405663R1000 1SVR405663R4000 1SVR405664R0000 1SVR405664R0100 1SVR405664R1000 1SVR405664R1100 1SVR405664R4000 1SVR405664R4100 1SVR405665R0000 1SVR405665R0100 1SVR405665R1000 1SVR405665R1100 1SVR405665R4000 1SVR405665R4100 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 1SVR405667R0000 1SVR405669R0000 1SVR405670R0000 1SVR405670R1100 1SVR406570R0000 1SVR406580R0000 1SVR423418R9000 1SVR427030R0000 1SVR427030R2000 1SVR427031R0000 1SVR427031R2000 1SVR427032R0000

Page 405 405 394 403 403 394 403 394 394 403 403 407 407 407 408 408 408 408 408 408 408 408 408 408 408 408 408 408 408 408 409 409 409 409 409 409 409 409 409 409 407 407 407 452 452 342 260 260 260 260 260

Type CP-E 12/2.5 CP-E 5/3.0 CP-E 24/5.0 CP-E 48/5.0 CP-E 24/10.0 CP-E 12/10.0 CP-E 48/10.0 CP-E 24/20.0 CP-D 24/0.42 CP-D 12/0.83 CP-D 24/1.3 CP-D 12/2.1 CP-D 24/2.5 CP-D 24/4.2 CP-D RU CP-T 24/5.0 CP-T 48/5.0 CP-T 24/10.0 CP-T 48/10.0 CP-T 24/20.0 CP-T 48/20.0 CP-T 24/40.0 CP-B 24/3.0 CP-B 24/10.0 CP-B 24/20.0 CP-B EXT.2 COV.01 ADP.01 ADP.01 MAR.02 COV.02 ADP.02 CM-SE-300 CM-SE-600 CM-SE-1000 CM-KH-3 CM-AH-3 CM-GM-1 CM-CT 50/1 CM-CT 75/1 CM-CT 100/1 CM-CT 150/1 CM-CT 200/1 CM-CT 50/5 CM-CT 75/5 CM-CT 100/5 CM-CT 150/5 CM-CT 200/5 CM-CT 300/1 CM-CT 400/1 CM-CT 500/1

Order code 1SVR427032R1000 1SVR427033R3000 1SVR427034R0000 1SVR427034R2000 1SVR427035R0000 1SVR427035R1000 1SVR427035R2000 1SVR427036R0000 1SVR427041R0000 1SVR427041R1000 1SVR427043R0100 1SVR427043R1200 1SVR427044R0200 1SVR427045R0400 1SVR427049R0000 1SVR427054R0000 1SVR427054R2000 1SVR427055R0000 1SVR427055R2000 1SVR427056R0000 1SVR427056R2000 1SVR427057R0000 1SVR427060R0300 1SVR427060R1000 1SVR427060R2000 1SVR427065R0000 1SVR430005R0100 1SVR430029R0100 1SVR430029R0100 1SVR430043R0000 1SVR440005R0100 1SVR440029R0100 1SVR450056R0000 1SVR450056R0100 1SVR450056R0200 1SVR450056R6000 1SVR450056R7000 1SVR450056R8000 1SVR450116R1000 1SVR450116R1100 1SVR450116R1200 1SVR450116R1300 1SVR450116R1400 1SVR450116R5000 1SVR450116R5100 1SVR450116R5200 1SVR450116R5300 1SVR450116R5400 1SVR450117R1100 1SVR450117R1200 1SVR450117R1300

Page 260 260 260 260 260 260 260 260 318 318 318 318 318 318 342 280 280 280 280 280 280 280 332 332 332 332 242 41 242 242 242 242 242 242 242 242 242 242 243 243 243 243 243 243 243 243 243 243 243 243 243

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX
-- Index Order code

Type CM-CT 600/1 CM-CT 300/5 CM-CT 400/5 CM-CT 500/5 CM-CT 600/5 CM-CT A CM-IWM.10 CM-IWM.11 CT-MFD.12 CT-MFD.21 CT-ERD.12 CT-ERD.22 CT-AHD.12 CT-AHD.22 CT-VWD.12 CT-EBD.12 CT-TGD.12 CT-TGD.22 CT-SAD.22 CT-SDD.22 CT-MKC.31 CT-MFC.12 CT-MFC.21 CT-ERC.12 CT-ERC.22 CT-AHC.12 CT-AHC.22 CT-ARC.12 CT-VWC.12 CT-EBC.12 CT-TGC.12 CT-TGC.22 CT-SAC.22 CT-SDC.22 CM-MSE CM-MSE CM-MSE CM-PFE CM-PFE.2 CM-ENE MAX CM-ENE MIN CM-ENE MAX CM-ENE MIN CM-ENE MAX CM-ENE MIN CM-PVE CM-PVE CM-PBE CM-PBE CM-UFD.M31 CM-UFD.M33

Order code 1SVR450117R1400 1SVR450117R5100 1SVR450117R5200 1SVR450117R5300 1SVR450117R5400 1SVR450118R1000 1SVR470670R1000 1SVR470670R1100 1SVR500020R0000 1SVR500020R1100 1SVR500100R0000 1SVR500100R0100 1SVR500110R0000 1SVR500110R0100 1SVR500130R0000 1SVR500150R0000 1SVR500160R0000 1SVR500160R0100 1SVR500210R0100 1SVR500211R0100 1SVR508010R1300 1SVR508020R0000 1SVR508020R1100 1SVR508100R0000 1SVR508100R0100 1SVR508110R0000 1SVR508110R0100 1SVR508120R0000 1SVR508130R0000 1SVR508150R0000 1SVR508160R0000 1SVR508160R0100 1SVR508210R0100 1SVR508211R0100 1SVR550800R9300 1SVR550801R9300 1SVR550805R9300 1SVR550824R9100 1SVR550826R9100 1SVR550850R9400 1SVR550850R9500 1SVR550851R9400 1SVR550851R9500 1SVR550855R9400 1SVR550855R9500 1SVR550870R9400 1SVR550871R9500 1SVR550881R9400 1SVR550882R9500 1SVR560730R3401 1SVR560730R3402

Page 243 243 243 243 243 243 161 161 57 57 57 57 57 57 57 57 57 57 57 57 25 25 25 25 25 25 25 25 25 25 25 25 25 25 190 190 190 113 113 229 229 229 229 229 229 113 113 113 113 145 145

Type CM-UFD.M22M CM-UFD.M31M CM-UFD.M33M CM-UFD.M34M COV.11 COV.11 MAR.12 MAR.12 CT-MFS.21S CT-MBS.22S CT-MVS.21S CT-MVS.12S CT-MVS.22S CT-MVS.23S CT- MXS.22S CT-WBS.22S CT-ERS.21S CT-ERS.12S CT-ERS.22S CT-AHS.22S CT-ARS.11S CT-ARS.21S CT-APS.21S CT-APS.12S CT-APS.22S CT-SDS.22S CT-SDS.23S CM-IWS.1S CM-IWS.2S CM-MSS.12S CM-MSS.22S CM-MSS.13S CM-MSS.23S CM-MSS.32S CM-MSS.41S CM-MSS.51S CM-MSS.31S CM-MSS.33S CM-MSS.11S CM-MSS.21S CM-TCS.11S CM-TCS.12S CM-TCS.13S CM-TCS.21S CM-TCS.22S CM-TCS.23S CM-EFS.2S CM-SFS.21S CM-SFS.22S CM-PAS.31S CM-PAS.41S

Order code 1SVR560731R3700 1SVR560731R3701 1SVR560731R3702 1SVR560731R3703 1SVR730005R0100 1SVR730005R0100 1SVR730006R0000 1SVR730006R0000 1SVR730010R0200 1SVR730010R3200 1SVR730020R0200 1SVR730020R3100 1SVR730020R3300 1SVR730021R2300 1SVR730030R3300 1SVR730040R3300 1SVR730100R0300 1SVR730100R3100 1SVR730100R3300 1SVR730110R3300 1SVR730120R3100 1SVR730120R3300 1SVR730180R0300 1SVR730180R3100 1SVR730180R3300 1SVR730210R3300 1SVR730211R2300 1SVR730660R0100 1SVR730670R0200 1SVR730700R0100 1SVR730700R0200 1SVR730700R2100 1SVR730700R2200 1SVR730712R0200 1SVR730712R1200 1SVR730712R1300 1SVR730712R1400 1SVR730712R2200 1SVR730720R1400 1SVR730722R1400 1SVR730740R0100 1SVR730740R0200 1SVR730740R0300 1SVR730740R9100 1SVR730740R9200 1SVR730740R9300 1SVR730750R0400 1SVR730760R0400 1SVR730760R0500 1SVR730774R1300 1SVR730774R3300

471
Page 145 145 145 145 41 242 41 242 39 39 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 40 40 161 161 190 190 190 190 190 190 190 190 190 190 190 209 209 209 209 209 209 89 87 87 113 113

472

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

-- Index Order code

Type CM-PSS.31S CM-PSS.41S CM-PVS.31S CM-PVS.81S CM-PVS.41S CM-PFS.S CM-ESS.1S CM-ESS.2S CM-ESS.MS CM-ESS.1S CM-ESS.2S CM-ESS.1S CM-ESS.2S CM-SRS.11S CM-SRS.12S CM-SRS.21S CM-SRS.22S CM-SRS.M1S CM-SRS.M2S CM-SRS.11S CM-SRS.12S CM-SRS.21S CM-SRS.22S CM-SRS.11S CM-SRS.12S CM-SRS.21S CM-SRS.22S CM-ENS.11S CM-ENS.21S CM-ENS.31S CM-ENS.11P CM-ENS.23S CM-MPS.31S CM-MPS.41S CM-MPS.43S CM-MPS.11S CM-MPS.21S CM-MPS.23S CT-MFS.21P CT-MBS.22P CT-MVS.21P CT-MVS.12P CT-MVS.22P CT-MVS.23P CT-MXS.22P CT-WBS.22P CT-ERS.21P CT-ERS.12P CT-ERS.22P CT-AHS.22P CT-ARS.11P

Order code 1SVR730784R2300 1SVR730784R3300 1SVR730794R1300 1SVR730794R2300 1SVR730794R3300 1SVR730824R9300 1SVR730830R0300 1SVR730830R0400 1SVR730830R0500 1SVR730831R0300 1SVR730831R0400 1SVR730831R1300 1SVR730831R1400 1SVR730840R0200 1SVR730840R0300 1SVR730840R0400 1SVR730840R0500 1SVR730840R0600 1SVR730840R0700 1SVR730841R0200 1SVR730841R0300 1SVR730841R0400 1SVR730841R0500 1SVR730841R1200 1SVR730841R1300 1SVR730841R1400 1SVR730841R1500 1SVR730850R0100 1SVR730850R0200 1SVR730850R0300 1SVR730850R2100 1SVR730850R2200 1SVR730884R1300 1SVR730884R3300 1SVR730884R4300 1SVR730885R1300 1SVR730885R3300 1SVR730885R4300 1SVR740010R0200 1SVR740010R3200 1SVR740020R0200 1SVR740020R3100 1SVR740020R3300 1SVR740021R2300 1SVR740030R3300 1SVR740040R3300 1SVR740100R0300 1SVR740100R3100 1SVR740100R3300 1SVR740110R3300 1SVR740120R3100

Page 113 113 113 113 113 113 89 89 89 89 89 89 89 87 87 87 87 87 87 87 87 87 87 87 87 87 87 229 229 229 229 229 115 115 115 115 115 115 39 39 39 39 39 39 39 39 40 40 40 40 40

Type CT-ARS.21P CT-APS.21P CT-APS.12P CT-APS.22P CT-SDS.22P CT-SDS.23P CM-IWS.1P CM-IWS.2P CM-MSS.12P CM-MSS.22P CM-MSS.13P CM-MSS.23P CM-MSS.32P CM-MSS.41P CM-MSS.51P CM-MSS.31P CM-MSS.33P CM-MSS.11P CM-MSS.21P CM-TCS.11P CM-TCS.12P CM-TCS.13P CM-TCS.21P CM-TCS.22P CM-TCS.23P CM-EFS.2P CM-SFS.21P CM-PAS.31P CM-PAS.41P CM-PSS.31P CM-PSS.41P CM-PVS.31P CM-PVS.81P CM-PVS.41P CM-PFS.P CM-ESS.1P CM-ESS.2P CM-ESS.MP CM-ESS.1P CM-ESS.2P CM-ESS.1P CM-ESS.2P CM-SRS.11P CM-SRS.21P CM-SRS.M1P CM-SRS.11P CM-SRS.21P CM-SRS.11P CM-SRS.21P CM-ENS.13S CM-ENS.21P

Order code 1SVR740120R3300 1SVR740180R0300 1SVR740180R3100 1SVR740180R3300 1SVR740210R3300 1SVR740211R2300 1SVR740660R0100 1SVR740670R0200 1SVR740700R0100 1SVR740700R0200 1SVR740700R2100 1SVR740700R2200 1SVR740712R0200 1SVR740712R1200 1SVR740712R1300 1SVR740712R1400 1SVR740712R2200 1SVR740720R1400 1SVR740722R1400 1SVR740740R0100 1SVR740740R0200 1SVR740740R0300 1SVR740740R9100 1SVR740740R9200 1SVR740740R9300 1SVR740750R0400 1SVR740760R0400 1SVR740774R1300 1SVR740774R3300 1SVR740784R2300 1SVR740784R3300 1SVR740794R1300 1SVR740794R2300 1SVR740794R3300 1SVR740824R9300 1SVR740830R0300 1SVR740830R0400 1SVR740830R0500 1SVR740831R0300 1SVR740831R0400 1SVR740831R1300 1SVR740831R1400 1SVR740840R0200 1SVR740840R0400 1SVR740840R0600 1SVR740841R0200 1SVR740841R0400 1SVR740841R1200 1SVR740841R1400 1SVR740850R0100 1SVR740850R0200

Page 40 40 40 40 40 40
161 161 190 190 190 190 190 190 190 190 190 190 190 209 209 209 209 209 209
89 87 113 113 113 113 113 113 113 113 89 89 89 89 89 89 89 87 87 87 87 87 87 87 229 229

ELECTRONIC RELAYS AND CONTROLS CATALOGINDEX

473

-- Index Order code

Type CM-ENS.31P CM-ENS.13P CM-ENS.23P CM-MPS.31P CM-MPS.41P CM-MPS.43P CM-MPS.11P CM-MPS.21P CM-MPS.23P COV.12 CM-MPN.52S CM-MPN.62S CM-MPN.72S CM-IWN.1S CM-IVN.S CM-MPN.52P CM-MPN.62P CM-MPN.72P CM-IWN.1P CM-IVN.P EPD24-TB-101-1A EPD24-TB-101-2A EPD24-TB-101-3A EPD24-TB-101-4A EPD24-TB-101-6A EPD24-TB-101-8A EPD24-TB-101-10A EPD24-TB-101-12A EPD24-TB-101-0.5A EPD-BB500 EPD-SB21 C011-70 C011-80 C011-90 C011-100 C011-110 C011-120 C011-130 C011-150 C011-160 C011-170 C011-140 C011-3-150 SK 615 562-87 SK 615 562-88

Order code 1SVR740850R0300 1SVR740850R2100 1SVR740850R2200 1SVR740884R1300 1SVR740884R3300 1SVR740884R4300 1SVR740885R1300 1SVR740885R3300 1SVR740885R4300 1SVR750005R0100 1SVR750487R8300 1SVR750488R8300 1SVR750489R8300 1SVR750660R0200 1SVR750669R9400 1SVR760487R8300 1SVR760488R8300 1SVR760489R8300 1SVR760660R0200 1SVR760669R9400 2CDE601101R2001 2CDE601101R2002 2CDE601101R2003 2CDE601101R2004 2CDE601101R2006 2CDE601101R2008 2CDE601101R2010 2CDE601101R2012 2CDE601101R2905 2CDE605100R0500 2CDE605200R0021 GHC0110003R0001 GHC0110003R0002 GHC0110003R0003 GHC0110003R0004 GHC0110003R0005 GHC0110003R0006 GHC0110003R0007 GHC0110003R0008 GHC0110003R0009 GHC0110003R0010 GHC0110003R0011 GHC0110033R0008 GJD6155620R0087 GJD6155620R0088

Page 229 229 229 115 115 115 115 115 115 242 115 115 115 161 161 115 115 115 161 161 352 352 352 352 352 352 352 352 352 352 352 191 191 191 191 191 191 191 191 191 191 191 191 41 41

--
ABB STOTZ-KONTAKT GmbH Eppelheimer Strasse 82 69123 Heidelberg Germany You can find the address of your local sales organization on the ABB homepage
abb.com/lowvoltage

2CDC110004C0210 Rev. E (01/2020)

--
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents ­ in whole or in parts ­ is forbidden without prior written consent of ABB AG Copyright© 2020 ABB AG All rights reserved


Adobe PDF Library 15.0 Adobe InDesign 15.0 (Windows)