This manual is intended to meet the Manufacturer’s Instructions as required by the American National Standards Institute (ANSI) Z359 and should be used as part of an employee training program as required by the Occupational Safety and Health Administration (OSHA).

Temporary Cable Horizontal Lifeline

PDF MHLL12 REV C Full Letter English 112219
jj
Steel
GRIP
Temporary Cable Horizontal Lifeline
User Instruction Manual

The FallTech SteelGrip® Temporary Cable Horizontal Lifeline (HLL) is designed as a temporary reusable anchorage subsystem for the attachment of up to two personal fall arrest systems (PFASs). The FallTech SteelGrip® Temporary Cable HLL described in this manual when used as instructed in this manual is OSHA 1910.140 and 1926.502 compliant.
This manual is intended to meet the Manufacturer's Instructions as required by the American National Standards Institute (ANSI) Z359 and should be used as part of an employee training program as required by the Occupational Safety and Health Administration (OSHA).

MHLL12 Rev C

112219

Table of Contents
1.0 Warnings and Important Information .................................................................................. 3 2.0 Application ........................................................................................................................... 4 3.0 System Requirements .......................................................................................................... 8 4.0 Installation and Use ............................................................................................................. 9 5.0 Maintenance, Service and Storage ...................................................................................... 13 6.0 Inspection ............................................................................................................................ 13 7.0 Labels ................................................................................................................................... 14 8.0 Definitions ........................................................................................................................... 15
Appendix A ......................................................................................................................... 17

For the purposes of this manual, the FallTech SteelGrip® Temporary Horizontal Lifeline may be referred to as the HLL, the system or the lifeline.
Throughout this manual, ANSI Z359.0-2012 fall protection words, phases and terms are used. These terms are all formally defined in Section 8.0 of this manual.

MHLL12 Rev C

112219

2

1.0 Warnings and Important Information
WARNING
· Avoid moving machinery, thermal, electrical and/or chemical hazards as contact may cause serious injury or death. · Avoid swing falls. · Follow the weight restrictions and recommendations in this manual. · Remove from service any equipment subjected to fall arrest forces. · Remove from service any equipment that fails inspection. · Do not alter or intentionally misuse this equipment. · Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual. · Do not connect rebar hooks, large carabiners, or large snap hooks to the FBH dorsal D-rings as this may cause a roll-out condition and/or
unintentional disengagement. · Avoid sharp and/or abrasive surfaces and edges. · Use caution when performing arc welding. Arc flash from arc welding operations, including accidental arcs from electrical equipment, can
damage equipment and are potentially fatal. · Examine the work area. Be aware of the surroundings and workplace hazards that may impact safety, security, and the functioning of fall
arrest systems and components. · Hazards may include but not be limited to cable or debris tripping hazards, equipment failures, personnel mistakes, moving equipment
such as carts, barrows, fork lifts, cranes, or dollies. Do not allow materials, tools or equipment in transit to contact any part of the fall arrest system. · Do not work under suspended loads.
IMPORTANT
This product is part of a personal fall arrest, restraint, work positioning, suspension, or rescue system. A Personal Fall Arrest System (PFAS) is typically composed of an anchorage and a Full Body Harness (FBH), with a connecting device, i.e., a Shock Absorbing Lanyard (SAL), or a Self-Retracting Device (SRD), attached to the dorsal D-ring of the FBH.
These instructions must be provided to the worker using this equipment. The worker must read and understand the manufacturer's instructions for each component or part of the complete system. Manufacturer's instructions must be followed for proper use, care, and maintenance of this product. These instructions must be retained and be kept available for the worker's reference at all times. Alterations or misuse of this product, or failure to follow instructions, may result in serious injury or death.
A Fall Protection Plan must be on file and available for review by all workers. It is the responsibility of the worker and the purchaser of this equipment to assure that users of this equipment are properly trained in its use, maintenance, and storage. Training must be repeated at regular intervals. Training must not subject the trainee to fall hazards.
Consult a doctor if there is reason to doubt your fitness to safely absorb the shock of a fall event. Age and fitness seriously affect a worker's ability to withstand falls. Pregnant women or minors must not use this equipment.
ANSI limits the weight of fall protection equipment users to a maximum of 310 lbs. Products in this manual may have a rated capacity exceeding ANSI capacity limits. Heavy users experience more risk of serious injury or death due to falls because of increased fall arrest forces placed on the user's body. In addition, the onset of suspension trauma after a fall even may be accelerated for heavy users.
The user of the equipment discussed in this manual must read and understand the entire manual before beginning work.
NOTE: For more information consult the ANSI Z359 body of standards.

MHLL12 Rev C

112219

3

2.0 Application

2.1

Purpose: The purpose of the FallTech SteelGrip® Temporary Cable HLL is to provide horizontal mobility for workers exposed to fall hazards

and is designed as an anchorage subsystem for the attachment of up to two PFASs. The HLL is adjustable up to 100' in length for

a single span system and up to 360' in length for a multi-span system. The system is designed to be used as part of a complete PFAS. See

Figure 1.

Figure 1 - Personal Fall Arrest System

A B

CC

FF

E

A

D

B

A Carabiner

G

B SteelGrip® Coil Energy Absorber

G

G

C Cable Clips

D Tension Indicator (Optional)

E Turnbuckle

F Cable Swage

G Shackle

When properly tensioned, the lifeline will react to a fall event of up to two workers by combining the energy absorbing properties of the lifeline cable, the SteelGrip® Coil Energy Absorber, and the worker's personal energy absorber. During a fall event, the SteelGrip® Coil Energy Absorber will deploy and elongate to safely and predictably absorb the energy of the fall event. The elongation of the SteelGrip® Coil Energy Absorber along with the stretch of the lifeline and the expansion of the user's PFAS will result in reduced forces to the anchor and to the user's body.

2.2

Application Limits: The FallTech SteelGrip® Temporary Cable HLL is a dynamic anchorage subsystem that will vary in its performance

depending upon the length of the system, the number of workers attached and the type of PFAS being used. Care should be taken to

understand the capacity of the system, minimum required fall clearance, anchorage strength requirements, total allowable free fall, total

allowable fall clearance, and how the user's PFAS will deploy during a fall event. Longer HLL spans will generate more lifeline deflection

and sag during a fall event and will result in greater clearance requirements. See Figure 2.

Figure 2 - Clearance Requirements

B

A

C

B

G

D

H

D

G

F

E

F

A B
C G
D E F

A

A

B D GH

F

A Deployed In-Line Energy Absorber E Height of Worker

B Dynamic Lifeline Sag

F Safety Factor

C Deployed SAL

G Total Required Fall Clearance

D D-ring Shift and Harness Stretch H Total SRD Deceleration Distance from User's Manual*

* If SRD Deceleration Distance is unknown, use 2 feet for ANSI Z359.14 Class A SRDs or use 4-1/2 feet for ANSI Z359.14 Class B SRDs.

MHLL12 Rev C

112219

4

2.3

System Capacity: The FallTech SteelGrip® Temporary Cable HLL maximum capacity is two workers simultaneously, with each worker

weighing no more than 310 Lbs. inclusive of clothing, tools, etc. For multiple span systems, maximum capacity is two workers per span

with a maximum of six total workers per system, see Figures 3 and 4.

2.4

Anchorage Requirements: End anchors selected for use with this system must be a minimum of 5,000 lbs. (22.2 kN).

2.5

Total Allowable Free Fall: OSHA limits free fall to 6' or less. The HLL system described in this manual is designed to be used overhead and

free fall should be limited to 6' unless otherwise specified by a specific anchorage solution.

2.6

PFAS Selection: Only FallTech PFASs may be used in conjunction with this HLL system. The HLL may be used with FallTech shock

absorbing lanyards, FallTech self-retracting devices and FallTech fall arrestor connecting subsystems.

2.7 2.7.1

Clearance Requirements: The FallTech SteelGrip® Temporary Cable HLL is designed to react to a fall event by elongating and deflecting to absorb energy. PFAS attached to the HLL will also elongate during a fall event. It is important to understand clearance requirements prior to installation and use of the system. See tables and charts below for calculating minimum required fall clearance.
Minimum Required Fall Clearance for One Worker w/SAL
Figure 3 - SteelGrip® Temporary Cable HLL with SAL Minimum Fall Clearance (Maximum One Worker)
1
A
2

B 3

C

SteelGrip® Temporary Cable HLL with SAL Minimum Required Fall Clearance

310 lbs. Maximum User Capacity

Max. One Worker

1 Find Span Length in Table Below

2 Find Freefall Distance in Table Below

3 Required Fall Clearance at the intersection of Span Length and Freefall Distance (see table below)

A. Overhead Anchorage B. Walking/Working Surface C. Nearest Lower Level or Obstruction

* Work below HLL to avoid Swing Fall

Span Length (feet)

0 - 30 31 - 40 41 - 50 51 - 60 61 - 70 71 - 80 81 - 90 91 - 100

0
15.0' 16.0' 17.0' 18.0' 18.5' 19.5' 20.0' 20.5'

Freefall Distance (feet)

1

2

3

4

5

16.0' 17.0' 18.0' 19.0' 19.5' 20.5' 21.0' 21.5'

17.0' 18.0' 19.0' 20.0' 20.5' 21.5' 22.0' 22.5'

18.0' 19.0' 20.0' 21.0' 21.5' 22.5' 23.0' 23.5'

19.0' 20.0' 21.0' 22.0' 22.5' 23.5' 24.0' 24.5'

20.0' 21.0' 22.0' 22.5' 23.5' 24.5' 25.0' 25.5'

6
21.0' 22.0' 23.0' 24.0' 24.5' 25.5' 26.0' 26.5'

7 *
22.0' 23.0' 24.0' 25.0' 25.5' 26.5' 27.0' 27.5'

* 7' Freefall Distance scenario is only allowed when the SteelGrip® Temporary Cable HLL attached to the FallTech SteelGrip® Stanchion. Freefall should be limited to 6' or less when used with any other anchorage connector.

MHLL12 Rev C

112219

5

2.7.2 Minimum Required Fall Clearance for Two Workers w/SAL
Figure 4 - SteelGrip® Temporary Cable HLL with SAL Minimum Fall Clearance (Maximum Two Workers) 1
A 2
B

3

C

SteelGrip® Temporary Cable HLL with SAL Minimum Required Fall Clearance

310 lbs. Maximum User Capacity Each

Max. Two Workers

1

Find Span Length in Table Below

2

Find Freefall Distance in Table Below

3

Required Fall Clearance at the intersection of Span Length and Freefall Distance (see table below)

A. Overhead Anchorage B. Walking/Working Surface C. Nearest Lower Level or Obstruction

* Work below HLL to avoid Swing Fall

0 - 30 31 - 40 41 - 50 51 - 60 61 - 70 71 - 80 81 - 90 91 - 100

0 17.0' 18.5' 19.5' 21.0' 22.5' 24.5' 26.0' 27.5'

1 18.0' 19.5' 20.5' 22.0' 23.5' 25.5' 27.0' 28.5'

Freefall Distance (feet)

2

3

4

19.0' 20.0' 21.0'

20.5' 21.5' 22.5'

21.5' 22.5' 23.5'

23.0' 24.0' 25.0'

24.5' 25.5' 26.5'

26.5' 27.5' 28.5'

28.0' 29.0' 30.0'

29.5' 30.5' 31.5'

5 20.0' 23.5' 24.5' 26.0' 27.5' 29.5' 31.0' 32.5'

6 23.0' 24.5' 25.5' 27.0' 28.5' 30.5' 32.0' 33.5'

7 * 24.0' 25.5' 26.5' 28.0' 29.5' 31.5' 33.0' 34.5'

* 7' Freefall Distance scenario is only allowed when the SteelGrip® Temporary Cable HLL is attached
to the FallTech SteelGrip® Stanchion. Freefall should be limited to 6' or less when used with any other anchorage connector.

Span Length (feet)

MHLL12 Rev C

112219

6

2.7.3

Minimum Required Fall Clearance for up to Two Workers w/SRDs
When attaching up to two Self-Retracting Devices (SRD) to the FallTech SteelGrip® Cable HLL system shown in Figure 5, it is permissible to calculate the required clearance below the working surface by including the typical SRD deceleration distances detailed in the SRD user's instruction manual. Calculating total clearance requirements using typical performance attributes for the SRD will generally result in reduced clearance requirements.

Figure 5 - SteelGrip® Temporary Cable HLL with SRD Minimum Fall Clearance (Maximum Two Workers) 1
A

2

B

3

C

SteelGrip® Temporary Cable HLL with SRD Minimum Required Fall Clearance

310 lbs. Maximum User Capacity Each

Max. Two Workers

A

Final Vertical HLL Sag (see chart on the following page)

B

Total SRD Deceleration Distance from User Instruction Manual*

C

1 ft

D-ring Shift and Harness Stretch

D

3 ft

Safety Factor

Sub Total - Minimum Required Fall Clearance E
for direct overhead use of SRD (sum of A, B, C and D only)

* Additional Fall Clearance Calculation

F

1 ft

due to the use of stanchions

G

Total Minimum Required Fall Clearance When Using Stanchions - (Sum of E and F)

1. Overhead Anchorage 2. Walking/Working Surface 3. Nearest Lower Level or Obstruction
* If SRD Deceleration Distance is unknown, use 2 feet for ANSI Z359.14 Class A SRDs or use 4-1/2 feet for ANSI Z359.14 Class B SRDs.
** Work below HLL to avoid Swing Fall

MHLL12 Rev C

112219

7

Final Vertical HLL Sag for Fall Clearance Calculation When Using SRD(s)

Span Length (feet)

0 - 30 31 - 40 41 - 50 51 - 60 61 - 70 71 - 80 81 - 90 91 - 100

One Worker 4.5' 5.5' 6.0' 7.0' 8.0' 9.0' 9.5' 10.5'

Two Workers 6.5' 8.0' 9.0' 10.5' 12.0' 14.0' 16.0' 18.0'

For worst case clearance calculations the user of the FallTech SteelGrip® Cable HLL systems may opt to use the ANSI Z359.14 maximum deceleration distances when determining clearance requirements. ANSI Z359.14 allows up to 24" of deceleration for Class A SRDs and up to 54" of deceleration for Class B SRDs. The charts below demonstrate clearance requirements below the working surface when using the FallTech SteelGrip® Temporary Cable HLL and attaching either Class A or Class B SRDs to the HLL. Overhead anchorage only.

Required Clearance When Connected to HLL Using ANSI Z359.14 Class A SRDs

One Worker

0 - 30

10.5'

31 - 40 41 - 50 51 - 60 61 - 70 71 - 80 81 - 90 91 - 100

11.5' 12.0' 13.0' 14.0' 15.0' 15.5' 16.5'

Two Workers 12.5' 14.0' 15.0' 16.5' 18.0' 20.0' 22.0' 24.0'

Span Length (feet)

Required Clearance When Connected to HLL Using ANSI Z359.14 Class B SRDs

One Worker

0 - 30

13.0'

31 - 40

14.0'

41 - 50

14.5'

51 - 60

15.5'

61 - 70

16.5'

71 - 80

17.5'

81 - 90

18.0'

91 - 100

19.0'

Two Workers 15.0' 16.5' 17.5' 19.0' 20.5' 22.5' 24.5' 26.5'

Span Length (feet)

2.8

Rescue: The FallTech SteelGrip® Temporary Cable HLL is part of a complete PFAS. It is not intended as a rescue device. Users of this

system presents a wide variety of potential rescue scenarios. Users of this system should understand their work environment and

develop a rescue plan accordingly. It is recommended that a trained on-site rescue team be present during use of the system.

3.0 System Requirements

3.1

Anchorage Strength: End anchors selected for use with this system must have a minimum rating of 5,000 lbs. (22.2 kN).

3.2

Structure: The mounting points for the anchorage must be capable of supporting no less than 5000lbs, see Figure 6.

Figure 6 - Anchorage Strength Requirements

5000lbs (22.2kN) Minimum

5000lbs (22.2kN) Minimum

5000lbs (22.2kN) Minimum
MHLL12 Rev C

112219

5000lbs (22.2kN) Minimum
8

3.2

Compatibility of Connectors: Connectors are considered to be compatible with connecting elements when they have been designed to

work together in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open regardless of how

they become oriented. Contact FallTech if you have any questions about compatibility. Connectors must be compatible

with the anchorage or other system components. Do not use equipment that is not compatible. Non-compatible connectors

may unintentionally disengage. Connectors must be compatible in size, shape, and strength. Self-closing, self-locking snap hooks

and carabiners are specified by OSHA and ANSI Z359.12.

3.3

Compatibility of Components: Equipment is designed for use with approved components and subsystems only. Substitutions or

replacements made with non-ANSI Z359 compliant components or subsystems may jeopardize compatibility of equipment and may affect

the safety and reliability of the complete system. Ensure compatibility between the connectors if non-FallTech components are used for

fall protection.

3.4

Connectors: Only use self-locking snap hooks, rebar hooks, and carabiners with this equipment. Only use connectors that are suitable to

each application. Ensure all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Visually

ensure all connectors close and lock completely. Connectors (snap hooks, rebar hooks, and carabiners) are designed for use only

as specified in this manual.

4.0 Installation and Use

The FallTech SteelGrip® Temporary Cable HLL is sold in a variety of kits and configurations. The assembly instructions listed below may refer to components not included in each kit. For a list of parts included in each kit, see Appendix A.

4.1

Plan the Personal Fall Arrest System (PFAS): Inspect the HLL subsystem before each use in accordance with the procedures detailed in

Section 6. Examine the work area and take action to address hazards. Falls are a serious hazard when working at height. Training and

equipment are the tools of fall hazard management. There are several closely related facets of fall hazard management with a PFAS;

· Anchor Point Selection
· Anchorage Connector
· Deceleration Device · Maximum Arrest Force
· Deceleration Distance
· Minimum Required Fall Clearance (MRFC) · Body Wear
· Rescue

4.2

Anchor Point Selection: Select a suitable anchor point. Consider the area where the work is being performed. In an overhead anchorage

condition, the area below the anchorage is the work zone. Lateral movement away from the anchorage is hazardous. As distance from

the anchor increases, the work zone expands, and so does the hazard. Work zone expansion is measured in feet and has a direct influence

on user safety. Always work as close to the anchor as possible. End anchors selected for use with this system must be a minimum of 5,000

lbs. (22.2 kN). See list of compatible FallTech anchors in Appendix A.

4.3

Anchorage Connector: Anchorage Connectors used as part of a PFAS should be designed for use with specified anchor points and

compatible with the PFAS components and connectors to be used in the assembly of a complete PFAS. Care should be taken to ensure

proper assembly, installation and maintenance of all Anchorage Connectors to be used when planning a PFAS. Failure to inspect,

assemble, install and/or maintain Anchorage Connectors could result in injury or death.

4.4

Connectors/Deceleration Devices: Connectors and Deceleration Devices such as Shock Absorbing Lanyards, Self-Retracting

Devices/Lifelines, and Fall Arrestor Connector Subsystems (Vertical Lifeline/Rope Grab Combinations) are designed to connect the user's

body wear to the Anchorage Connector and/or Anchor Point of a Personal Fall Arrest System.

4.5

Product Assembly and Installation: System installation requires end anchor points that are a minimum of 5000 Lbs. in both

vertical and horizontal directions. The lifeline should be installed to limit free fall to 6' or less*. When using SRDs the lifeline

must be positioned overhead*. The horizontal lifeline should be positioned in a manner to minimize free fall while allowing ease of use.

Movement away from the lifeline should be limited to reduce the potential for swing fall. Lifeline end anchors should be

installed at approximately the same elevation so that the lifeline itself is not sloped more than 5 degrees.

* When using SteelGrip® Stanchions as end anchors for this system, free fall may exceed 6' when using a shock absorbing lanyard (SAL), see Section 2.7. SRDs are acceptable for use as personal energy absorbers.

MHLL12 Rev C

112219

9

4.6 Lifeline Component Assembly
Step 1: Attach a carabiner to one end of the SteelGrip® Coil Energy Absorber as shown in Figure 7.

Step 2: Assembly without FallTech Tension Indicator, skip to Step 3.

Assembly with FallTech Tension Indicator:

Remove cotter pins, unthread nuts, and remove bolts of two shackles. Attach a shackle on either side of the FallTech Tension Indicator. Align one shackle with the remaining hole of the SteelGrip® Coil Energy Absorber, insert the shackle bolts, thread on and tighten nuts, and insert cotter pins into both shackles as shown in Figure 8.

Step 3:

Rotate the body of the turnbuckle to expand the connection points away from each other as shown in Figure 9. Being sure the jaws are expanded equally on both sides and that there are still threads visible inside the turnbuckle body.

Step 4: Remove the cotter pins from the bolts in the turnbuckle. Then unthread the nuts and remove the bolts.

Step 5: Assembly without FallTech Tension Indicator:

Align the jaws of one end of the turnbuckle with the open end of the SteelGrip® Coil Energy Absorber. Insert a turnbuckle bolt through the aligned holes, thread on the nut and insert the cotter pin as shown in Figure 10.

Assembly with FallTech Tension Indicator:

Align the jaws of one end of the turnbuckle with the open shackle on the FallTech Tension Indicator. Insert a turnbuckle bolt through the aligned holes, thread on the nut and insert the cotter pin as shown in Figure 11.

Step 6:

Align the other jaw of the turnbuckle with the termed end of the cable. Insert a turnbuckle bolt through the aligned holes, thread on the nut and insert the cotter pin as shown in Figure 12.

Step 7:

At the appropriate length, term the cable by wrapping the cable around the thimble, attach the cable clamps as shown in Figure 13. Install one clamp at the base of the thimble and one clamp 3" away from other clamp. There should be at least 8" of excess cable beyond the second cable clamp.

Step 8: Attach the second carabiner to the thimble end of the cable as shown in Figure 14.

If the span is 60' or less, the system is ready to be installed. If the span is greater than 60', continue to step 9.

Step 9:

Remove the cotter pin of a shackle, unthread the nut and remove the bolt. Insert the shackle through the thimble end of the cable. Align the shackle holes with the hole in the second SteelGrip® Coil Energy Absorber. Insert the shackle bolt, thread on nut and insert cotter pin. See Figure 15.

Step 10: Attach the second carabiner to the other end of the SteelGrip® Coil Energy Absorber as shown in Figure 16.

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11

Figure 12

Figure 13 3"
8" Figure 15

Figure 14 Figure 16

MHLL12 Rev C

112219

10

4.7

Product Installation Using The FallTech SteelGrip® Stanchions (Single or Multiple Span):

Step 1:

The HLL system described in this manual is designed for use with the FallTech SteelGrip® Stanchions, which provide a minimum two to one safety factor relative to the loads applied by the system, see Figure 17. In order to reduce the required fall clearance, the use of intermediate stanchions to reduce span length is recommended. For more details see the FallTech SteelGrip® Stanchion User Instruction Manual.
Figure 17 - Stanchion System Loads
A

Beam Load Requirements - End Stanchions

Part # Configuration

A

B

C

D

B

D

SteelGrip® Temporary Cable HLL

620020 Through 620360

1-man 2-man

5,400 lbs 6,600 lbs

16,875 ft-lbs 20,625 ft-lbs

5,000 lbs 5,000 lbs

1,500 ft-lbs 3,000 ft-lbs

* All values include 2:1 safety factor as required by OSHA

C

Note:

The maximum single span length when using stanchions is 60', see Figure 18. The overall system length can be increased by using intermediate stanchions to create multiple spans in at most 60' increments. For multiple spans two FallTech SteelGrip® Coil Energy Absorbers must be used, see Figure 19.

Figure 18 - Maximum Single Span Length

Figure 19 - Multiple Span

60'

Step 2: Secure the HLL system to the end stanchions using the provided end attachment carabiners as shown in Figure 20.
Step 3: For single span systems, skip to step 4.

For multiple span systems:

Ensure the pass-through brackets are installed per the instructions in the FallTech SteelGrip® Stanchion User Manual. Ensure that the lifeline passes through the intermediate stanchion's pass through brackets as shown in Figure 21.

Step 4:

Holding the cable side jaw of the turnbuckle to prevent the lifeline from twisting, use a tool to rotate the turnbuckle. Rotate the turnbuckle so that the jaws draw toward each other as shown in Figure 22.

If a FallTech Tension Indicator is not being used, tighten the turnbuckle until the center of the lifeline sags no more than 6 inches below the end anchorage points.

If a FallTech Tension Indicator is being used, tighten the turn buckle until the indicator is located in the center green section of the window, as shown in Figure 23.

Step 5: Once properly tensioned, the lifeline subsytem can be used.

 60'

 60'

Figure 20

Figure 21 Figure 22 Figure 23

MHLL12 Rev C

112219

11

4.8

Product Installation (Single Span):

Step 1: Determine the locations of the end anchorage connectors. The anchorage selected for a PFAS must have the strength to sustain a static load applied in the direction permitted by the PFAS of at least two times the maximum arrest force permitted when certification exists, or 5,000 lbs. (22.2 kN) in the absence of certification.
Note: Single span lengths 60' and shorter use a single FallTech SteelGrip®Coil Energy Absorber, see Figure 24 . Single span lengths longer than 60' must use two FallTech SteelGrip® Coil Energy Absorbers, see Figure 25.

Figure 24 - Single Span up to 60'

Figure 25 - Single Spans longer than 60' and up to 100'

Step 2: Install the end anchorage connectors.

Step 3: Secure the HLL system to the anchorage connectors with the provided end attachment carabiners.

Step 4:

Holding the cable side jaw of the turnbuckle to prevent the lifeline from twisting, use a tool to rotate the turnbuckle. Rotate the turnbuckle so that the jaws draw toward each other as shown in Figure 26.

Figure 26

If a FallTech Tension Indicator is not being used, tighten the turnbuckle until the center of the lifeline sags no more than 6 inches below the end anchorage points.
If a FallTech Tension Indicator is being used, tighten the turnbuckle until the indicator is located in the center green section of the window as shown in Figure 27.
Step 5: Once properly tensioned, the lifeline subsytem can be used.

Figure 27

MHLL12 Rev C

112219

12

4.9

Connecting to the HLL System:

Approach the work area using the appropriate access equipment. Connect the PFAS connector (free end connector on the SAL or SRD) directly to the HLL wire rope. Do not connect to any component other than the wire rope. Connectors must meet all compatibility and strength requirements.

4.10 Releasing Lifeline Tension:
Upon completion of work, to move to a new location or to disconnect from the end anchorage connectors, lifeline tension should be released.

Figure 28

Step 1:

Holding the cable side jaw of the turnbuckle to prevent the lifeline from twisting, use a tool to rotate the turnbuckle. Rotate the turnbuckle so that the jaws draw away from each other as shown in Figure 28.

Step 2: Once enough tension has been removed from the lifeline, remove the end attachment carabiners from their anchor points.

5.0 Maintenance, Service and Storage

Maintenance: Service: Storage:

No scheduled maintenance is required, other than the replacement of items that failed inspection. There are no specific service requirements for this system component. If the unit is removed from its installation location, it should be stored in a dry area free of corrosive elements that may harm or cause the product not to function.

6.0 Inspection

5.1

Pre-Use Inspection: Prior to each the HLL system should be inspected by the user for damage, wear and to ensure the lifeline is properly

tensioned. Please review the inspection checklist for inspection requirements.

5.2

Inspection Frequency: Other than pre-use inspection, the FallTech SteelGrip® Horizontal Lifeline should be inspected by a competent

person at least once a year.

5.3

Inspection Checklist: A general inspection should be done at the intervals specified in this manual. Inspect as follows:

Step 1: Inspect labels. Ensure legibility of content. If labels are missing or illegible, remove the system from service.

Figure 29

Step 2:

Inspect all metal components for cracks, corrosion, deformities, missing or noticable defects. Metal components include: the FallTech SteelGrip®Coil Energy Absorber, optional tension indicator, turnbuckle, carabiner, thimble eyes, shackles and all other hardware.

Step 3:

Inspect the entire working length of wire rope for damage caused by chemical corruption or excessive heat as evident by discoloration (A), birdcaging (B), broken wire strands (C), kinks and bent strands (D), see Figure 29.

Step 4: Inspect the SteelGrip®Coil Energy Absorber, it should not be extended, cracked or deformed. Figure 30 shows the coil energy absorber in a non-deployed condition whereas Figure 31 shows the coil energy absorber in a partially deployed state. If there is tearing of the metal, remove from service and replace.

Figure 30

Figure 31

MHLL12 Rev C

112219

13

5.4

Inspection Results: Inspection results should be recorded by a competent person at least once a year.

5.5

Inspection Document: Record inspection results on the inspection record provided below, or similar document.

INSPECTION RECORD Model # Modelo N° :____________________

PLANILLA de INSPECCIÓN Serial # N° de serie :____________________

Inspection Date Fecha de inspección

Date of Manufacture Fecha de fabricación :____________________

Inspector Inspector

Comments Observaciones

Pass/Fail Pasó/No pasó

Corrective Action Needed Accion correctiva a realizer

Approved By Aprobado por

7.0 Labels
The labels must be present and legible.
SteelGrip®Coil Energy Absorber

Cable Subassembly Tension Indicator

MHLL12 Rev C

112219

14

8.0 Definitions

The following are general definitions of fall protection terms as defined by ANSI Z359.0-2012.
Anchorage -A secure connecting point or a terminating component of a fall protection system or rescue system capable of safely supporting the impact forces applied by a fall protection system or anchorage subsystem.
Anchorage Connector - A component or subsystem that functions as an interface between the anchorage and a fall protection, work positioning, rope access or rescue system for the purpose of coupling the system to the anchorage.
Arrest Distance - The total vertical distance required to arrest a fall. The arrest distance includes the deceleration distance and activation distance.
Authorized Person ­ A person assigned by the employer to perform duties at a location where the person will be exposed to a fall hazard.
Available Clearance - The distance from a reference point, such as the working platform, to the nearest obstruction that an authorized person might contact during a fall which, if struck, could cause injury.
Capacity - The maximum weight that a component, system or subsystem is designed to hold.
Certification - The act of attesting in writing that the criteria established by these standards or some other designated standard have been met.
Certified Anchorage - An anchorage for fall arrest, positioning, restraint or rescue systems that a qualified person certifies to be capable of supporting the potential fall forces that could be encountered during a fall.
Clearance - The distance from a specified reference point, such as the working platform or anchorage of a fall arrest system, to the lower level that a worker might encounter during a fall.
Clearance Requirement - The distance below an authorized person that must remain clear of obstructions in order to ensure that the authorized person does not make contact with any objects that would cause injury in the event of a fall.
Competent Person - An individual designated by the employer to be responsible for the immediate supervision, implementation and monitoring of the employer's managed fall protection program who, through training and knowledge, is capable of identifying, evaluating and addressing existing and potential fall hazards, and who has the employer's authority to take prompt corrective action with regard to such hazards.
Component - An element or integral assembly of interconnected elements intended to perform one function in the system.
Connecting Subsystem - An assembly, including the necessary connectors, comprised of all components, subsystems, or both, between the anchorage or anchorage connector and the harness attachment point.
Connector - A component or element that is used to couple parts of the system together.
Deceleration Distance - The vertical distance between the user's fall arrest attachment at the onset of fall arrest forces during a fall, and after the fall arrest attachment comes to a complete stop.
Energy (Shock) Absorber - A component whose primary function is to dissipate energy and limit deceleration forces which the system imposes on the body during fall arrest.
Fall Arrest - The action or event of stopping a free fall or the instant where the downward free fall has been stopped.
Fall Hazard - Any location where a person is exposed to a potential free fall.
Free Fall -The act of falling before a fall protection system begins to apply forces to arrest the fall.
Free Fall Distance - The vertical distance traveled during a fall, measured from the onset of a fall from a walking working surface to the point at which the fall protection system begins to arrest the fall.
Harness, Full Body - A body support designed to contain the torso and distribute the fall arrest forces over at least the upper thighs, pelvis, chest and shoulders.
Horizontal Lifeline ­ A component of a horizontal lifeline subsystem, consisting of a flexible line with connectors or other coupling means at both ends for securing it horizontally between two anchorages or anchorage connectors.
Horizontal Lifeline Subsystem ­ An assembly, including the necessary connectors, comprised of a horizontal lifeline component and, optionally, of: a) An energy absorbing component or, b) A lifeline tensioner component, or both. This subsystem is normally attached at each end to an anchorage or anchorage connector. The end anchorages have the same elevation.

MHLL12 Rev C

112219

15

Horizontal Lifeline ­ A component of a horizontal lifeline subsystem, consisting of a flexible line with connectors or other coupling means at both ends for securing it horizontally between two anchorages or anchorage connectors.
Horizontal Lifeline Subsystem ­ An assembly, including the necessary connectors, comprised of a horizontal lifeline component and, optionally, of: a) An energy absorbing component or, b) A lifeline tensioner component, or both. This subsystem is normally attached at each end to an anchorage or anchorage connector. The end anchorages have the same elevation.
Lanyard - A component consisting of a flexible rope, wire rope or strap, which typically has a connector at each end for connecting to the body support and to a fall arrester, energy absorber, anchorage connector or anchorage.
Lanyard Connecting Subsystem - An assembly, including the necessary connectors, comprised of a lanyard only, or a lanyard and energy absorber.
Personal Fall Arrest System (PFAS) - An assembly of components and subsystems used to arrest a person in a free fall.
Positioning - The act of supporting the body with a positioning system for the purpose of working with hands free.
Positioning Lanyard - A lanyard used to transfer forces from a body support to an anchorage or anchorage connector in a positioning system.
Qualified Person - A person with a recognized degree or professional certificate and with extensive knowledge, training and experience in the fall protection and rescue field who is capable of designing, analyzing, evaluating and specifying fall protection and rescue systems.
Self-Retracting Device (SRD) - A device that contains a drum wound line that automatically locks at the onset of a fall to arrest the user, but that pays out from and automatically retracts onto the drum during normal movement of the person to whom the line is attached.
After onset of a fall, the device automatically locks the drum and arrests the fall. Self-retracting devices include self-retracting lanyards (SrL's), self-retracting lanyards with integral rescue capability (SrL-r's), and self-retracting lanyards with leading edge capability (SrL-Le's) and, hybrid combinations of these.
Snaphook - A connector comprised of a hook-shaped body with a normally closed gate or similar arrangement that may be opened to permit the hook to receive an object and, when released, automatically closes to retain the object.
Swing Fall - A pendulum-like motion that occurs during and/or after a vertical fall. A swing fall results when an authorized person begins a fall from a position that is located horizontally away from a fixed anchorage.

MHLL12 Rev C

112219

16

Appendix A

Model #
620020 to
620360

Specifications for FallTech SteelGrip® Temporary Cable HLL

Minimum Tensile Strength
and Material
5000 lbs. Minimum Tensile Strength
Cable: 3/8" Diameter 7X19 Galvanized Steel
SteelGrip® Coil Energy Absorber:
Stainless Steel
Turnbuckle: Drop Forged Galvanized Steel
Shackles: Drop Forged Galvanized Steel
Thimbles: Galvanized Steel
Carabiner: Zinc Plated Forged Alloy Steel
Cable Clips: Drop Forged Galvanized Steel
Tension Indicator: Zinc Plated Alloy Steel

Maximum User
Capacity
Maximum Two Workers at up to
310 lbs. Each

Standards and Regulations
OSHA 1926.502

Kit Contents

Part #
620020-620060 620070-620360
62100A 62103D 62102C 62101B 60230A-60260A 60280A-602100A 6033012-6036024 6038012-60310024 62201EA 62202S 62203C 62204D 62205T 623020-623360

List of Components by SteelGrip® Part #

SteelGrip Coil Energy Absorber

Ferruled Cable

Carabiners

Shackles

Turnbuckle

Cable Clamps

Thimbles

1

1

2

2

1

2

1

2

1

2

3

1

2

1

1

2

1

4

2

1

1

1

1

1

1

1

1

4

2

1

1

2

2

1

2

1

2

1

2

3

1

2

1

1

1

2

2

1

2

1

2

1

2

3

1

2

1

1

3

4

2

2

1

1

SteelGrip I-Beam Clamping Stanchion
2 2

Web Sling Tension Anchors Indicator
1 1

2

1

2

1

1

1

1

MHLL12 Rev C

112219

17

Item Number 603012K 603018K 603024K 7324 7414 7414P 7414SS 7428 7432 7433 7435 7435H 7438 7440 7440S 7441 7535 7536

FallTech Compatible Anchors
Item Name SteelGrip HLL I-Beam Stanchion with 4" to 12" Clamp SteelGrip HLL I-Beam Stanchion with 4" to 18" Clamp SteelGrip HLL I-Beam Stanchion with 4" to 24" Clamp 2' Pass-Through Sling Anchor Bolt-on D-ring Anchor Weld-on D-ring Anchor Bolt-on D-ring Anchor 6' Cable Pass-Through Sling Anchor, Coated Dual Truss Roof Anchor EcoAnchor Water-filled Counterweight Bolt-on D-Ring Anchor w/integral stud Bolt-on D-Ring Anchor 6' Cable Pass-Through Sling Anchor Removeable Concrete Anchor; 5K Removeable Concrete Anchor w/Swivel; 5K Removeable Concrete Anchor; 10K 12" Stationary Beam Clamp Anchor 24" Stationary Beam Clamp Anchor

Note: The above listing shows the most common FallTech anchors that are compatible with the FallTech SteelGrip® Temporary Cable HLL. Contact FallTech for additional information regarding other anchors not on this list.

MHLL12 Rev C

112219

18


Adobe PDF Library 15.0 Adobe InDesign 14.0 (Macintosh)