testo Instruments 05601045 Combined infrared and penetration thermometer with Bluetooth User Manual

testo Instruments (Shenzhen) Co., Ltd Combined infrared and penetration thermometer with Bluetooth Users Manual

Users Manual

Download: testo Instruments 05601045 Combined infrared and penetration thermometer with Bluetooth User Manual
Mirror Download [FCC.gov]testo Instruments 05601045 Combined infrared and penetration thermometer with Bluetooth User Manual
Document ID2679699
Application IDyTNRjpXLRj0r0fyvO+0M2A==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize43.81kB (547615 bits)
Date Submitted2015-07-15 00:00:00
Date Available2015-07-16 00:00:00
Creation Date2015-07-07 16:05:13
Producing SoftwareAdobe Acrobat Pro 9.3.2
Document Lastmod2015-07-15 09:36:30
Document TitleUsers Manual
Document CreatorAdobe Acrobat Pro 9.3.2

testo 104-IR BT
Combined infrared and penetration thermometer with
Bluetooth®
limi
pre
Instruction manual
en
Ensure correct disposal:
Dispose of defective rechargeable batteries and spent
batteries at the collection points provided.
Send the instrument directly to us at the end of its life cycle.
We will ensure that it is disposed of in an environmentally
friendly manner.
3. Intended use
The testo 104-IR BT is a robust food thermometer.
The product is designed for the following tasks/areas:
· Food sector: production, food service, spot check
measurement, incoming goods.
· Measuring liquids, pastes and semi-solid materials
The following product components are designed for continuous
contact with foodstuffs in accordance with Regulation (EC)
1935/2004:
The immersion/penetration probe from the tip up to 2 cm before the
probe handle or the plastic housing. If provided, information about
penetration depths in the instruction manual or the mark(s) on the
immersion/penetration probe should be observed.
The product should not be used in the following areas:
· Potentially explosive areas
· For diagnostic measurements in the medical sector
en
fr
es
it
pt
Adhere to the product safety/warranty requirements:
Always operate the instrument properly and according to its
intended purpose and within the parameters specified. Do not
use force.
Do not store with solvents (e.g. acetone).
Only open the instrument if this is expressly described in the
documentation for the purpose of maintenance or repair work.
sv
Avoid electrical hazards:
Do not conduct measurements on or near live parts!
nl
2. Safety information
??
preliminary
Please read this document through carefully and familiarize
yourself with the operation of the product before putting it to use.
Keep this document to hand so that you can refer to it when
necessary.
??
1. General information
de
1. General information 3
Certification
Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE),
Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland (IE),
Italy (IT), Latvia (LV), Lithuania (LT), Luxembourg (LU), Malta
(MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT),
Romania (RO), Sweden (SE), Slovakia (SK), Slovenia (SI), Spain
(ES), Czech Republic (CZ), Hungary (HU), United Kingdom (GB),
Republic of Cyprus (CY).
EFTA countries
Norway and Switzerland.
Other countries
USA, Canada, Turkey, Australia, New Zealand, South Korea,
India, Russia, Japan
Information from the FCC (Federal Communications
Commission)
This device complies with part 15 of the FCC Rules.
Commissioning is subject to the two following conditions: (1) This
instrument must not cause any harmful interference and (2) this
instrument must be able to cope with interference, even if this has
undesirable effects on operation.
Response time t99
Measuring rate
Infrared measurement
Lens
Spectral range
Laser type
Output / wavelength
Class / standard
Measuring range
Resolution
Accuracy (at 23°C, ±1 digit)
Measuring rate
General
Operating temperature
Transportation/
storage temperature
Power supply
Battery life
Housing
Protection class
Dimensions
Weight
Standards
EC Directive
Warranty
10:1 + opening diameter of the sensor (12 mm / 0.47”)
8 to 14 μm
2-point laser
< 1 mW / 650nm
2 / DIN EN 60825-1:2007
-30 - +250 °C / -22 - +482 °F
0.1 °C/°F/°R
±2.5 °C / ±4.5 °F (-30.0 to -20.1 °C / -22.0 to -4.2 °F)
±2.0 °C / ±3.6 °F (-20.0 to -0.1 °C / -4.1 to 31.9 °F)
±1.5 °C / ±2.7 °F or ±1.5 % of the measuring value (0.0 to
+250.0 °C / +32.0 to +482.0 °F)
0.5 s
-20 to +50 °C / -4 to +122 °F
-30...+70 °C / -22 to +158 °F (without batteries)
2 x AAA batteries
10 h (typical at 25°C / 77°F)
ABS/TPE/PC and die-cast zinc/stainless steel
IP65
281 x 48 x 21 mm / 11.06 x 1.89 x 0.83“ (immersion/
penetration probe folded out)
178 x 48 x 21 mm / 7.01 x 1.89 x 0.83”
(immersion/penetration probe folded up)
210g / 0.433lbs (incl. batteries)
EN 13485
2004/108/EC
2 years, warranty terms: see www.testo.com/warranty
Changes
The FCC demands that the user be informed that any changes or
modifications to the instrument that are not explicitly approved by
Testo AG may void the user’s right to use this instrument.
Information on standards
This product complies with the EN 13485 standard for
penetration measurement.
Suitability: S, T (storage, transportation)
Environment: E (transportable thermometer)
Accuracy class: 0.5
Measuring range: -50...+250 °C
According to EN 13485, the measuring instrument should
be checked and calibrated regularly under the terms of
EN 13486 (recommended frequency: yearly).
Contact us for more information.
en
fr
es
NTC
-50 to +250 °C / -58 to +482 °F
0.1 °C/°F/°R
±1.0 °C / ±1.8 °F (-50,0 to-30,1°C / -58.0 to -22.1 °F)
±0.5 °C / ±0.9 °F (-30,0 to +99,9°C / -22.0 to +211.9 °F)
±1 % of the measuring range (+100.0 to +250.0 °C / +212.0
to +482.0 °F)
10 s (measured in moving liquid)
0.5 s
it
Qualified Design ID
Bluetooth radio class
Bluetooth company
Values
Range >20 m (free field)
LSD Science & Technology Co., Ltd
L Series BLE Module (08 Mai 2013) based on TI CC254X chip
B016552
Class 3
10274
Values
pt
Feature
Bluetooth
luetooth type
Penetration probe
Sensor type
Measuring range
Resolution
Accuracy (±1 digit)
sv
preliminary
The Bluetooth® option may only be operated in countries in
which it is type approved.
Feature
nl
4.1 Bluetooth Modul
4.2 General Technical data
??
4. Technical data
de
5. Product description 5
??
4 4. Technical data
6 Battery compartment (at the back)
Switching on/off via control keys
Switch the instrument on: press [ON].
- All display segments light up briefly. IR measurement is
enabled (
lights up).
Switch off the instrument: press and hold down [OFF] until the
display goes off.
The instrument switches off automatically if no key is pressed:
for 10 minutes when the probe is folded out, or for 1 minute
when the probe is folded up.
7.2 Changing the measuring mode
Contact measurement —> IR measurement: press [ ].
IR measurement —> contact measurement: press [ ].
7.3 Measuring
6. Commissioning
Inserting batteries
1 Use a slotted screwdriver to undo the
screw on the battery compartment.
2 Open the battery compartment.
3 Insert batteries (2x type AAA). Observe
the polarity!
4 Close the battery compartment.
5 Tighten the screw.
Observe the information on IR measurement/contact
measurement (see chapter below).
Bluetooth mode Cnl1 (Controlled Mode) is enabled: Display
shows bLE, all buttons are locked, instrument can be
controlled by external mobile device only.
IR measurement
- Instrument is on, IR measurement is enabled, Bluetooth mode
Cnl2 (Autonomous Mode) is enabled.
1 Start measurement: press and hold down [ ].
Lock in on measurement object using the laser points:
laser points mark the edges of the measuring range.
- The current measuring value is displayed.
3 End measurement: release the key.
- Hold lights up. The last measuring value and min./max. value
are saved until the next measurement, or until the instrument is
switched off.
4 Send data to mobile device: press [HOLD / MIN / MAX].
Switch between min., max. and recorded value: press [HOLD /
MIN / MAX].
en
Fold out the probe.
- All display segments light up briefly. Contact measurement is
enabled (
lights up).
fr
4 Control keys:
· [ON]: switches the instrument on
· [OFF]: switches the instrument off
(hold button down)
· [ ]: switches to IR measurement,
carry out IR measurement (hold button
down)
· [ ]: switches to contact measurement
· [HOLD/MIN/MAX]: holds measuring
value, displays minimum/maximum
value, sends data to mobile device
(Bluetooth)
5 Fold-out immersion/penetration probe,
folding out the probe switches the
instrument on
es
Switching on via fold-out probe
it
3 Display
pt
7.1 Switching on/off
sv
2 2-point laser
nl
preliminary
1 Infrared sensor
7. Operation
??
5. Product description
de
8. Settings 7
??
6 7. Operation
· switch the instrument off, switch to IR measurement or, while
the held measuring value is displayed (Hold lights up), press
and hold down [HOLD / MIN / MAX] until Clr lights up.
Restart measurement: press [ ].
8. Settings
- The instrument is switched off.
If no button is pressed for 3 s in settings mode, the instrument
switches to the next view.
1 Press and hold down [ ] and [ ] until AutoHold or Hold
flashes.
2 Switch the AutoHold function on (AutoHold) or off (Hold): press
[ ] or [ ].
- °C, °F or °R flashes.
3 Set measurement unit to degrees Celsius (°C), degrees
Fahrenheit (°F) or degrees Réaumur (°R): press [ ] or [ ].
- flashes.
4 Switch the laser on (on) or off (oFF): press [ ] or [ ].
4 Close the battery compartment.
5 Tighten the screw.
9.2 Cleaning the instrument
Only use weak, commercially available neutral/household cleaning
agents (e.g. washing-up liquid) to clean the instrument. Do not
use aggressive cleaning agents or solvent!
The housing and probe can be disinfected using an alcoholbased spray. In doing so, always follow the manufacturer’s
instructions.
Clean the housing and probe under running water and rub dry
with a towel.
Clean the lens carefully with a cotton bud dipped in water or
medical alcohol.
10. Questions and answers
Question
lights up
IR measurement:
- - - lights up.
Contact measurement:
- - - lights.
Instrument cannot
be switched on
Instrument
switches itself off.
de
en
3 Insert batteries (2x type AAA). Observe
the polarity!
it
2 Open the battery compartment.
pt
1 Use a slotted screwdriver to undo the
screw on the battery compartment.
sv
9.1 Changing the batteries
es
fr
9. Service and maintenance
nl
· press [ ] or switch the instrument off.
Restart measurement: press and hold down [ ].
Setting the emission level:
· When IR measurement is enabled, press and hold down[ ]
and [ ] at the same time (
lights up).
· Emission level is displayed.
· Use [ ] or [ ] to change the value and wait for 3 s.
Contact measurement
- Instrument is on, contact measurement is enabled (
lights
up), Bluetooth mode Cnl2 (Autonomous Mode) is enabled.
1 Position the contact thermometer in the measurement object
and initiate the measurement: press [ ].
2 End measurement: press [HOLD / MIN / MAX].
- Hold lights up. The last measuring value and min./max. value
are saved until the next measurement, or until the instrument is
switched off.
AutoHold function: if this function is enabled, the measurement
is ended automatically as soon as the measuring value is
stable, AutoHold lights up.
4 Send data to mobile device: press [HOLD / MIN / MAX].
Switch between min., max. and recorded value:
press [HOLD / MIN / MAX].
The min./max. values can be reset:
5 Select Bluetooth mode Cnl1 (Controlled Mode) oder Cnl2
(Autonomous Mode): press [ ] or [ ].
- The instrument switches to IR measurement.
Possible causes
Low battery
Measuring values
outside measuring range
Valores de medición
outside permissible range
Batteries dead.
Possible solution
Change batteries.
Keep to permissible
measuring range.
Keep to measuring
range.
Change batteries.
Instrument switches off
automatically after 10 min
in contact measurement mode
and after 1 min after switching
on in IR measurement mode.
Switch the
instrument on again
If we have not been able to answer your question, please contact
your local dealer or Testo Customer Service. For contact details,
please visit www.testo.com/service-contact.
??
preliminary
The min./max. values can be reset:
11. Information on infrared (IR) measurement 9
??
8 9. Service and maintenance
10 12. Information on contact measurement
11.2 Emissivity
Materials have different emission levels. This means they emit
various amounts of electromagnetic radiation. The emission level
of the instrument has a default setting of 0.95. This is ideal for
the measurement of food, non-metals (paper, ceramic, gypsum,
wood, paints and varnishes) and plastics.
de
en
fr
sv
pt
it
es
In italics = laser
Not in italics = measuring range
nl
IR measurement is a visual measurement
Keep lens clean.
Do not carry out measurement with a foggy lens.
Keep the measuring range (the range between the instrument
and the measurement object) free of obstacles. There must be
no particles of dust or dirt, no humidity (rain, steam) and no
gases.
IR measurement is a surface measurement
If there is dirt, dust, frost, etc. on the surface, only the outermost
layer is measured, i.e. the dirt.
For vacuum-packed food, do not measure at air pockets.
Where the values are critical, always measure separately
with a contact thermometer. Particularly in the food sector:
measure core temperature with a penetration/immersion
thermometer.
Adjustment time
If the ambient temperature changes (change of location,
e.g. measurement indoors/outdoors), the instrument must be
allowed to equalise for 15 minutes for infrared measurement.
Depending on the distance of the measuring instrument from the
measurement object, a specific measuring range is recorded.
Measuring lens (ratio of distance : measuring range)
* Optimised measuring distance
12. Information on contact
measurement
Observe the minimum penetration depth for immersion/
penetration probes:
10x probe diameter
Avoid using in aggressive acids or alkalis.
??
preliminary
11.1 Measuring method
11.3 Measuring range, distance
??
11. Information on infrared (IR)
measurement
11
Postfach 11 40, 79849 Lenzkirch
Testo-Straße 1, 79853 Lenzkirch
Telefon: (0 76 53) 6 81 - 0
Fax: (0 76 53) 6 81 - 1 00
E-Mail: info@testo.de
Internet: http://www.testo.com
www.testo.com
preliminary
testo AG
0977 1042 en 01a
FCC statements:
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications or changes to this equipment. Such modifications or
changes could void the user’s authority to operate the equipment.
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Power is so low that no RF exposure calculation is needed.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2015:07:07 16:05:13+08:00
Creator                         : Adobe Acrobat Pro 9.3.2
Modify Date                     : 2015:07:15 09:36:30+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2015:07:15 09:36:30+08:00
Creator Tool                    : Adobe Acrobat Pro 9.3.2
Format                          : application/pdf
Document ID                     : uuid:d4deffca-931e-4fba-a4a2-8b0c3f29508c
Instance ID                     : uuid:15482a6e-a335-4658-bf77-acf7c58b609c
Producer                        : Adobe Acrobat Pro 9.3.2
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ACVD05601045

Navigation menu