testo Instruments 05601045 Combined infrared and penetration thermometer with Bluetooth User Manual
testo Instruments (Shenzhen) Co., Ltd Combined infrared and penetration thermometer with Bluetooth Users Manual
Users Manual
testo 104-IR BT Combined infrared and penetration thermometer with Bluetooth® limi pre Instruction manual en Ensure correct disposal: Dispose of defective rechargeable batteries and spent batteries at the collection points provided. Send the instrument directly to us at the end of its life cycle. We will ensure that it is disposed of in an environmentally friendly manner. 3. Intended use The testo 104-IR BT is a robust food thermometer. The product is designed for the following tasks/areas: · Food sector: production, food service, spot check measurement, incoming goods. · Measuring liquids, pastes and semi-solid materials The following product components are designed for continuous contact with foodstuffs in accordance with Regulation (EC) 1935/2004: The immersion/penetration probe from the tip up to 2 cm before the probe handle or the plastic housing. If provided, information about penetration depths in the instruction manual or the mark(s) on the immersion/penetration probe should be observed. The product should not be used in the following areas: · Potentially explosive areas · For diagnostic measurements in the medical sector en fr es it pt Adhere to the product safety/warranty requirements: Always operate the instrument properly and according to its intended purpose and within the parameters specified. Do not use force. Do not store with solvents (e.g. acetone). Only open the instrument if this is expressly described in the documentation for the purpose of maintenance or repair work. sv Avoid electrical hazards: Do not conduct measurements on or near live parts! nl 2. Safety information ?? preliminary Please read this document through carefully and familiarize yourself with the operation of the product before putting it to use. Keep this document to hand so that you can refer to it when necessary. ?? 1. General information de 1. General information 3 Certification Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE), Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland (IE), Italy (IT), Latvia (LV), Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania (RO), Sweden (SE), Slovakia (SK), Slovenia (SI), Spain (ES), Czech Republic (CZ), Hungary (HU), United Kingdom (GB), Republic of Cyprus (CY). EFTA countries Norway and Switzerland. Other countries USA, Canada, Turkey, Australia, New Zealand, South Korea, India, Russia, Japan Information from the FCC (Federal Communications Commission) This device complies with part 15 of the FCC Rules. Commissioning is subject to the two following conditions: (1) This instrument must not cause any harmful interference and (2) this instrument must be able to cope with interference, even if this has undesirable effects on operation. Response time t99 Measuring rate Infrared measurement Lens Spectral range Laser type Output / wavelength Class / standard Measuring range Resolution Accuracy (at 23°C, ±1 digit) Measuring rate General Operating temperature Transportation/ storage temperature Power supply Battery life Housing Protection class Dimensions Weight Standards EC Directive Warranty 10:1 + opening diameter of the sensor (12 mm / 0.47”) 8 to 14 μm 2-point laser < 1 mW / 650nm 2 / DIN EN 60825-1:2007 -30 - +250 °C / -22 - +482 °F 0.1 °C/°F/°R ±2.5 °C / ±4.5 °F (-30.0 to -20.1 °C / -22.0 to -4.2 °F) ±2.0 °C / ±3.6 °F (-20.0 to -0.1 °C / -4.1 to 31.9 °F) ±1.5 °C / ±2.7 °F or ±1.5 % of the measuring value (0.0 to +250.0 °C / +32.0 to +482.0 °F) 0.5 s -20 to +50 °C / -4 to +122 °F -30...+70 °C / -22 to +158 °F (without batteries) 2 x AAA batteries 10 h (typical at 25°C / 77°F) ABS/TPE/PC and die-cast zinc/stainless steel IP65 281 x 48 x 21 mm / 11.06 x 1.89 x 0.83“ (immersion/ penetration probe folded out) 178 x 48 x 21 mm / 7.01 x 1.89 x 0.83” (immersion/penetration probe folded up) 210g / 0.433lbs (incl. batteries) EN 13485 2004/108/EC 2 years, warranty terms: see www.testo.com/warranty Changes The FCC demands that the user be informed that any changes or modifications to the instrument that are not explicitly approved by Testo AG may void the user’s right to use this instrument. Information on standards This product complies with the EN 13485 standard for penetration measurement. Suitability: S, T (storage, transportation) Environment: E (transportable thermometer) Accuracy class: 0.5 Measuring range: -50...+250 °C According to EN 13485, the measuring instrument should be checked and calibrated regularly under the terms of EN 13486 (recommended frequency: yearly). Contact us for more information. en fr es NTC -50 to +250 °C / -58 to +482 °F 0.1 °C/°F/°R ±1.0 °C / ±1.8 °F (-50,0 to-30,1°C / -58.0 to -22.1 °F) ±0.5 °C / ±0.9 °F (-30,0 to +99,9°C / -22.0 to +211.9 °F) ±1 % of the measuring range (+100.0 to +250.0 °C / +212.0 to +482.0 °F) 10 s (measured in moving liquid) 0.5 s it Qualified Design ID Bluetooth radio class Bluetooth company Values Range >20 m (free field) LSD Science & Technology Co., Ltd L Series BLE Module (08 Mai 2013) based on TI CC254X chip B016552 Class 3 10274 Values pt Feature Bluetooth luetooth type Penetration probe Sensor type Measuring range Resolution Accuracy (±1 digit) sv preliminary The Bluetooth® option may only be operated in countries in which it is type approved. Feature nl 4.1 Bluetooth Modul 4.2 General Technical data ?? 4. Technical data de 5. Product description 5 ?? 4 4. Technical data 6 Battery compartment (at the back) Switching on/off via control keys Switch the instrument on: press [ON]. - All display segments light up briefly. IR measurement is enabled ( lights up). Switch off the instrument: press and hold down [OFF] until the display goes off. The instrument switches off automatically if no key is pressed: for 10 minutes when the probe is folded out, or for 1 minute when the probe is folded up. 7.2 Changing the measuring mode Contact measurement —> IR measurement: press [ ]. IR measurement —> contact measurement: press [ ]. 7.3 Measuring 6. Commissioning Inserting batteries 1 Use a slotted screwdriver to undo the screw on the battery compartment. 2 Open the battery compartment. 3 Insert batteries (2x type AAA). Observe the polarity! 4 Close the battery compartment. 5 Tighten the screw. Observe the information on IR measurement/contact measurement (see chapter below). Bluetooth mode Cnl1 (Controlled Mode) is enabled: Display shows bLE, all buttons are locked, instrument can be controlled by external mobile device only. IR measurement - Instrument is on, IR measurement is enabled, Bluetooth mode Cnl2 (Autonomous Mode) is enabled. 1 Start measurement: press and hold down [ ]. Lock in on measurement object using the laser points: laser points mark the edges of the measuring range. - The current measuring value is displayed. 3 End measurement: release the key. - Hold lights up. The last measuring value and min./max. value are saved until the next measurement, or until the instrument is switched off. 4 Send data to mobile device: press [HOLD / MIN / MAX]. Switch between min., max. and recorded value: press [HOLD / MIN / MAX]. en Fold out the probe. - All display segments light up briefly. Contact measurement is enabled ( lights up). fr 4 Control keys: · [ON]: switches the instrument on · [OFF]: switches the instrument off (hold button down) · [ ]: switches to IR measurement, carry out IR measurement (hold button down) · [ ]: switches to contact measurement · [HOLD/MIN/MAX]: holds measuring value, displays minimum/maximum value, sends data to mobile device (Bluetooth) 5 Fold-out immersion/penetration probe, folding out the probe switches the instrument on es Switching on via fold-out probe it 3 Display pt 7.1 Switching on/off sv 2 2-point laser nl preliminary 1 Infrared sensor 7. Operation ?? 5. Product description de 8. Settings 7 ?? 6 7. Operation · switch the instrument off, switch to IR measurement or, while the held measuring value is displayed (Hold lights up), press and hold down [HOLD / MIN / MAX] until Clr lights up. Restart measurement: press [ ]. 8. Settings - The instrument is switched off. If no button is pressed for 3 s in settings mode, the instrument switches to the next view. 1 Press and hold down [ ] and [ ] until AutoHold or Hold flashes. 2 Switch the AutoHold function on (AutoHold) or off (Hold): press [ ] or [ ]. - °C, °F or °R flashes. 3 Set measurement unit to degrees Celsius (°C), degrees Fahrenheit (°F) or degrees Réaumur (°R): press [ ] or [ ]. - flashes. 4 Switch the laser on (on) or off (oFF): press [ ] or [ ]. 4 Close the battery compartment. 5 Tighten the screw. 9.2 Cleaning the instrument Only use weak, commercially available neutral/household cleaning agents (e.g. washing-up liquid) to clean the instrument. Do not use aggressive cleaning agents or solvent! The housing and probe can be disinfected using an alcoholbased spray. In doing so, always follow the manufacturer’s instructions. Clean the housing and probe under running water and rub dry with a towel. Clean the lens carefully with a cotton bud dipped in water or medical alcohol. 10. Questions and answers Question lights up IR measurement: - - - lights up. Contact measurement: - - - lights. Instrument cannot be switched on Instrument switches itself off. de en 3 Insert batteries (2x type AAA). Observe the polarity! it 2 Open the battery compartment. pt 1 Use a slotted screwdriver to undo the screw on the battery compartment. sv 9.1 Changing the batteries es fr 9. Service and maintenance nl · press [ ] or switch the instrument off. Restart measurement: press and hold down [ ]. Setting the emission level: · When IR measurement is enabled, press and hold down[ ] and [ ] at the same time ( lights up). · Emission level is displayed. · Use [ ] or [ ] to change the value and wait for 3 s. Contact measurement - Instrument is on, contact measurement is enabled ( lights up), Bluetooth mode Cnl2 (Autonomous Mode) is enabled. 1 Position the contact thermometer in the measurement object and initiate the measurement: press [ ]. 2 End measurement: press [HOLD / MIN / MAX]. - Hold lights up. The last measuring value and min./max. value are saved until the next measurement, or until the instrument is switched off. AutoHold function: if this function is enabled, the measurement is ended automatically as soon as the measuring value is stable, AutoHold lights up. 4 Send data to mobile device: press [HOLD / MIN / MAX]. Switch between min., max. and recorded value: press [HOLD / MIN / MAX]. The min./max. values can be reset: 5 Select Bluetooth mode Cnl1 (Controlled Mode) oder Cnl2 (Autonomous Mode): press [ ] or [ ]. - The instrument switches to IR measurement. Possible causes Low battery Measuring values outside measuring range Valores de medición outside permissible range Batteries dead. Possible solution Change batteries. Keep to permissible measuring range. Keep to measuring range. Change batteries. Instrument switches off automatically after 10 min in contact measurement mode and after 1 min after switching on in IR measurement mode. Switch the instrument on again If we have not been able to answer your question, please contact your local dealer or Testo Customer Service. For contact details, please visit www.testo.com/service-contact. ?? preliminary The min./max. values can be reset: 11. Information on infrared (IR) measurement 9 ?? 8 9. Service and maintenance 10 12. Information on contact measurement 11.2 Emissivity Materials have different emission levels. This means they emit various amounts of electromagnetic radiation. The emission level of the instrument has a default setting of 0.95. This is ideal for the measurement of food, non-metals (paper, ceramic, gypsum, wood, paints and varnishes) and plastics. de en fr sv pt it es In italics = laser Not in italics = measuring range nl IR measurement is a visual measurement Keep lens clean. Do not carry out measurement with a foggy lens. Keep the measuring range (the range between the instrument and the measurement object) free of obstacles. There must be no particles of dust or dirt, no humidity (rain, steam) and no gases. IR measurement is a surface measurement If there is dirt, dust, frost, etc. on the surface, only the outermost layer is measured, i.e. the dirt. For vacuum-packed food, do not measure at air pockets. Where the values are critical, always measure separately with a contact thermometer. Particularly in the food sector: measure core temperature with a penetration/immersion thermometer. Adjustment time If the ambient temperature changes (change of location, e.g. measurement indoors/outdoors), the instrument must be allowed to equalise for 15 minutes for infrared measurement. Depending on the distance of the measuring instrument from the measurement object, a specific measuring range is recorded. Measuring lens (ratio of distance : measuring range) * Optimised measuring distance 12. Information on contact measurement Observe the minimum penetration depth for immersion/ penetration probes: 10x probe diameter Avoid using in aggressive acids or alkalis. ?? preliminary 11.1 Measuring method 11.3 Measuring range, distance ?? 11. Information on infrared (IR) measurement 11 Postfach 11 40, 79849 Lenzkirch Testo-Straße 1, 79853 Lenzkirch Telefon: (0 76 53) 6 81 - 0 Fax: (0 76 53) 6 81 - 1 00 E-Mail: info@testo.de Internet: http://www.testo.com www.testo.com preliminary testo AG 0977 1042 en 01a FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Power is so low that no RF exposure calculation is needed.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2015:07:07 16:05:13+08:00 Creator : Adobe Acrobat Pro 9.3.2 Modify Date : 2015:07:15 09:36:30+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2015:07:15 09:36:30+08:00 Creator Tool : Adobe Acrobat Pro 9.3.2 Format : application/pdf Document ID : uuid:d4deffca-931e-4fba-a4a2-8b0c3f29508c Instance ID : uuid:15482a6e-a335-4658-bf77-acf7c58b609c Producer : Adobe Acrobat Pro 9.3.2 Page Count : 8EXIF Metadata provided by EXIF.tools