u blox LISAU201 3.75G HSPA Wireless Module User Manual LISA U2 series
u-blox AG 3.75G HSPA Wireless Module LISA U2 series
u blox >
Contents
- 1. Installation Instructions
- 2. LISA-U2_SysIntegrManual
Installation Instructions
LISA-U2 series 3.75G HSPA / HSPA+ Cellular Modules System Integration Manual Abstract This document describes the features and the system integration of LISA-U2 series HSPA+ cellular modules. These modules are complete and cost efficient 3.75G solutions offering up to six-band HSDPA/HSUPA and quad-band GSM/EGPRS voice and/or data transmission technology in a compact form factor. www.u-blox.com UBX-13001118 - R19 LISA-U2 series - System Integration Manual Document Information Title LISA-U2 series Subtitle 3.75G HSPA / HSPA+ Cellular Modules Document type System Integration Manual Document number UBX-13001118 Revision, date R19 Document status Early Production Information 09-Sep-2015 Document status explanation Objective Specification Document contains target values. Revised and supplementary data will be published later. Advance Information Document contains data based on early testing. Revised and supplementary data will be published later. Early Production Information Document contains data from product verification. Revised and supplementary data may be published later. Production Information Document contains the final product specification. This document applies to the following products: Product name Type number Modem version LISA-U200 LISA-U200-01S-00 LISA-U200-02S-00 22.40 22.90 LISA-U200-03S-00 23.41 LISA-U200-52S-00 LISA-U200-62S-00 22.86 22.90 LISA-U200-82S-00 LISA-U200-83S-00 22.92 23.41 LISA-U201 LISA-U230 LISA-U201-03S-00 LISA-U230-01S-00 23.41 22.40 LISA-U260 LISA-U260-01S-00 22.61 UBX-TN-12061 LISA-U270 LISA-U260-02S-00 LISA-U270-01S-00 22.90 22.61 UBX-13003492 UBX-TN-12061 LISA-U270-02S-00 LISA-U270-62S-00 22.90 22.90 UBX-13003492 UBX-13003492 LISA-U270-68S-00 22.93 LISA-U200 FOTA Application version PCN / IN UBX-TN-12040 UBX-13003492 A01.01 UBX-15020745 UBX-13004628 UBX-13003492 A01.01 A01.01 A01.03 UBX-13004629 UBX-15020745 UBX-15020745 UBX-TN-12040 UBX-15019240 u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of u-blox is strictly prohibited. The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, visit www.u-blox.com. Copyright © 2015, u-blox AG. u-blox® is a registered trademark of u-blox Holding AG in the EU and other countries. ARM® is the registered trademark of ARM Limited in the EU and other countries. UBX-13001118 - R19 Page 2 of 175 LISA-U2 series - System Integration Manual Preface How to use this Manual The LISA-U2 series System Integration Manual provides the necessary information to successfully design in and configure these u-blox cellular modules. This manual has a modular structure. It is not necessary to read it from the beginning to the end. The following symbols are used to highlight important information within the manual: An index finger points out key information pertaining to module integration and performance. A warning symbol indicates actions that could negatively impact or damage the module. u-blox Technical Documentation As part of our commitment to customer support, u-blox maintains an extensive volume of technical documentation for our products. In addition to our product-specific technical data sheets, the following manuals are available to assist u-blox customers in product design and development. AT Commands Manual: This document provides the description of the supported AT commands by the LISA-U2 modules to verify all implemented functionalities. System Integration Manual: This Manual provides hardware design instructions and information on how to set up production and final product tests. Application Note: document provides general design instructions and information that applies to all u-blox Cellular modules. See Related documents for a list of Application Notes related to your Cellular Module. Questions If you have any questions about u-blox Cellular Integration, please: Read this manual carefully. Contact our information service on the homepage http://www.u-blox.com Read the questions and answers on our FAQ database on the homepage http://www.u-blox.com Technical Support Worldwide Web Our website (www.u-blox.com) is a rich pool of information. Product information, technical documents and helpful FAQ can be accessed 24h a day. By E-mail Contact the closest Technical Support office by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document. Helpful Information when Contacting Technical Support When contacting Technical Support, have the following information ready: Module type (e.g. LISA-U200) and firmware version Module configuration Clear description of your question or the problem A short description of the application Your complete contact details UBX-13001118 - R19 Early Production Information Preface Page 3 of 175 LISA-U2 series - System Integration Manual Contents Preface ........................................................................................................................................... 3 Contents ........................................................................................................................................ 4 System description.................................................................................................................. 7 1.1 Overview .............................................................................................................................................................. 7 1.2 Architecture.......................................................................................................................................................... 9 1.2.1 Functional blocks .......................................................................................................................................... 9 1.3 Pin-out ............................................................................................................................................................... 11 1.4 Operating modes ................................................................................................................................................ 15 1.5 Power management ........................................................................................................................................... 17 1.5.1 Power supply circuit overview ..................................................................................................................... 17 1.5.2 Module supply (VCC) .................................................................................................................................. 18 1.5.3 Current consumption profiles ...................................................................................................................... 27 1.5.4 RTC Supply (V_BCKP) .................................................................................................................................. 32 1.5.5 Interface supply (V_INT) .............................................................................................................................. 35 1.6 System functions ................................................................................................................................................ 36 1.6.1 Module power-on ....................................................................................................................................... 36 1.6.2 Module power-off ...................................................................................................................................... 40 1.6.3 Module reset .............................................................................................................................................. 42 1.7 RF connection ..................................................................................................................................................... 44 1.8 (U)SIM interface .................................................................................................................................................. 45 1.8.1 1.9 (U)SIM application circuits ........................................................................................................................... 46 Serial communication ......................................................................................................................................... 52 1.9.1 Serial interfaces configuration ..................................................................................................................... 53 1.9.2 Asynchronous serial interface (UART) .......................................................................................................... 54 1.9.3 USB interface .............................................................................................................................................. 73 1.9.4 SPI interface ................................................................................................................................................ 78 1.9.5 MUX Protocol (3GPP 27.010) ...................................................................................................................... 83 1.10 DDC (I C) interface .............................................................................................................................................. 84 1.10.1 Overview .................................................................................................................................................... 84 1.10.2 DDC application circuits .............................................................................................................................. 84 1.11 Audio Interface ................................................................................................................................................... 89 1.11.1 I S interface - PCM mode ............................................................................................................................ 90 1.11.2 I S interface - Normal I S mode .................................................................................................................... 91 1.11.3 I S interface application circuits ................................................................................................................... 91 1.11.4 Voiceband processing system ...................................................................................................................... 94 1.12 General Purpose Input/Output (GPIO) .................................................................................................................. 96 1.13 Reserved pins (RSVD) ........................................................................................................................................ 103 1.14 Schematic for LISA-U2 module integration ........................................................................................................ 104 1.15 Approvals ......................................................................................................................................................... 105 1.15.1 R&TTED and European Conformance CE mark .......................................................................................... 106 1.15.2 US Federal Communications Commission notice ....................................................................................... 106 1.15.3 Industry Canada notice ............................................................................................................................. 108 1.15.4 ACMA Certification .................................................................................................................................. 110 UBX-13001118 - R19 Early Production Information Contents Page 4 of 175 LISA-U2 series - System Integration Manual 1.15.5 ICASA Certification ................................................................................................................................... 110 1.15.6 KCC Certification ...................................................................................................................................... 111 1.15.7 Anatel Certification ................................................................................................................................... 111 1.15.8 CCC Certification ..................................................................................................................................... 112 1.15.9 TELEC / JATE Certification ......................................................................................................................... 112 Design-In ............................................................................................................................. 113 2.1 Schematic checklist ................................................................................................................................... 113 2.1.2 Layout checklist ........................................................................................................................................ 114 2.1.3 Antenna checklist ..................................................................................................................................... 114 2.2 Design Guidelines for Layout............................................................................................................................. 115 2.2.1 Layout guidelines per pin function ............................................................................................................ 115 2.2.2 Footprint and paste mask.......................................................................................................................... 124 2.2.3 Placement................................................................................................................................................. 125 2.3 Thermal guidelines ............................................................................................................................................ 126 2.4 Antenna guidelines ........................................................................................................................................... 128 2.4.1 Antenna termination ................................................................................................................................ 130 2.4.2 Antenna radiation ..................................................................................................................................... 131 2.4.3 Examples of antennas ............................................................................................................................... 132 2.4.4 Antenna detection functionality ................................................................................................................ 134 2.5 Design-in checklist ............................................................................................................................................ 113 2.1.1 ESD guidelines .................................................................................................................................................. 135 2.5.1 ESD immunity test overview ...................................................................................................................... 135 2.5.2 ESD immunity test of u-blox LISA-U2 series reference designs .................................................................... 136 2.5.3 ESD application circuits ............................................................................................................................. 137 Features description ........................................................................................................... 140 3.1 Network indication ........................................................................................................................................... 140 3.2 Antenna detection ............................................................................................................................................ 140 3.3 Jamming Detection ........................................................................................................................................... 140 3.4 TCP/IP and UDP/IP ............................................................................................................................................. 141 3.4.1 Multiple PDP contexts and sockets ............................................................................................................ 141 3.5 FTP ................................................................................................................................................................... 141 3.6 HTTP ................................................................................................................................................................ 141 3.7 SSL/TLS ............................................................................................................................................................. 142 3.8 Dual stack IPv4/IPv6 .......................................................................................................................................... 143 3.9 AssistNow clients and GNSS integration ............................................................................................................ 144 3.10 Hybrid positioning and CellLocate .................................................................................................................... 144 ® ® 3.10.1 Positioning through cellular information: CellLocate ................................................................................. 144 3.10.2 Hybrid positioning .................................................................................................................................... 146 3.11 Control Plane Aiding / Location Services (LCS) ................................................................................................... 146 3.12 Firmware (upgrade) Over AT (FOAT) .................................................................................................................. 146 3.12.1 Overview .................................................................................................................................................. 146 3.12.2 FOAT procedure ....................................................................................................................................... 147 3.13 In-Band modem (eCall / ERA-GLONASS) ............................................................................................................ 147 3.14 SIM Access Profile (SAP) .................................................................................................................................... 147 3.15 Smart Temperature Management ..................................................................................................................... 149 3.15.1 Smart Temperature Supervisor (STS) .......................................................................................................... 149 UBX-13001118 - R19 Early Production Information Contents Page 5 of 175 LISA-U2 series - System Integration Manual 3.15.2 Threshold Definitions ................................................................................................................................ 151 3.16 Bearer Independent Protocol ............................................................................................................................. 151 3.17 Multi-Level Precedence and Pre-emption Service ............................................................................................... 151 3.18 Network Friendly Mode .................................................................................................................................... 152 3.19 Power saving .................................................................................................................................................... 152 Handling and soldering ...................................................................................................... 153 4.1 Packaging, shipping, storage and moisture preconditioning .............................................................................. 153 4.2 Soldering .......................................................................................................................................................... 153 4.2.1 Soldering paste ......................................................................................................................................... 153 4.2.2 Reflow soldering ....................................................................................................................................... 153 4.2.3 Optical inspection ..................................................................................................................................... 155 4.2.4 Cleaning ................................................................................................................................................... 155 4.2.5 Repeated reflow soldering ........................................................................................................................ 155 4.2.6 Wave soldering ......................................................................................................................................... 155 4.2.7 Hand soldering ......................................................................................................................................... 155 4.2.8 Rework ..................................................................................................................................................... 155 4.2.9 Conformal coating .................................................................................................................................... 155 4.2.10 Casting ..................................................................................................................................................... 156 4.2.11 Grounding metal covers ............................................................................................................................ 156 4.2.12 Use of ultrasonic processes ....................................................................................................................... 156 Product Testing ................................................................................................................... 157 5.1 u-blox in-series production test ......................................................................................................................... 157 5.2 Test parameters for OEM manufacturer ............................................................................................................ 157 5.2.1 ‘Go/No go’ tests for integrated devices...................................................................................................... 158 5.2.2 Functional tests providing RF operation ..................................................................................................... 158 Appendix ................................................................................................................................... 161 Migration from LISA-U1 to LISA-U2 series ......................................................................... 161 A.1 Checklist for migration ..................................................................................................................................... 161 A.2 Software migration ........................................................................................................................................... 161 A.2.1 A.3 Software migration from LISA-U1 series to LISA-U2 series modules ............................................................ 161 Hardware migration .......................................................................................................................................... 162 A.3.1 Hardware migration from LISA-U1 series to LISA-U2 series modules .......................................................... 162 A.3.2 Pin-out comparison LISA-U1 series vs. LISA-U2 series ................................................................................. 163 A.3.3 Layout comparison LISA-U1 series vs. LISA-U2 series .................................................................................. 170 Glossary ............................................................................................................................... 171 Related documents.................................................................................................................... 173 Revision history ......................................................................................................................... 174 Contact....................................................................................................................................... 175 UBX-13001118 - R19 Early Production Information Contents Page 6 of 175 LISA-U2 series - System Integration Manual 1 System description 1.1 Overview LISA-U2 cellular modules integrate full-feature 3G UMTS/HSxPA and 2G GSM/GPRS/EDGE protocol stack with Assisted GPS support. These SMT modules come in the compact LISA form factor, featuring Leadless Chip Carrier (LCC) packaging technology. 3G UMTS/HSDPA/HSUPA Characteristics 2G GSM/GPRS/EDGE Characteristics Class A User Equipment1 Class B Mobile Station2 UMTS Terrestrial Radio Access (UTRA) Frequency Division Duplex (FDD) 3GPP Release 7 (HSPA+) Rx Diversity for LISA-U230 GSM EDGE Radio Access (GERA) 3GPP Release 7 Rx Diversity for LISA-U230 2-band support for LISA-U260: Band II (1900 MHz), Band V (850 MHz) 2-band support for LISA-U270: Band I (2100 MHz), Band VIII (900 MHz) 5-band support for LISA-U201: Band I (2100 MHz), Band II (1900 MHz), Band V (850 MHz), Band VI (800 MHz), Band VIII (900 MHz) 6-band support for LISA-U200 and LISA-U230: Band I (2100 MHz), Band II (1900 MHz), Band IV (1700 MHz), Band V (850 MHz), Band VI (800 MHz), Band VIII (900 MHz) 4-band support GSM 850 MHz, E-GSM 900 MHz, DCS 1800 MHz, PCS 1900 MHz WCDMA/HSDPA/HSUPA Power Class Power Class 3 (24 dBm) for WCDMA/HSDPA/HSUPA mode GSM/GPRS Power Class Power Class 4 (33 dBm) for GSM/E-GSM bands Power Class 1 (30 dBm) for DCS/PCS bands EDGE Power Class Power Class E2 (27 dBm) for GSM/E-GSM bands Power Class E2 (26 dBm) for DCS/PCS bands PS (Packet Switched) Data Rate HSUPA category 6, up to 5.76 Mb/s UL HSDPA category 8 up to 7.2 Mb/s DL for LISA-U200, LISA-U201, LISA-U260 and LISA-U270 HSDPA category 14 up to 21.1 Mb/s DL for LISA-U230 WCDMA PS data up to 384 kb/s DL/UL PS (Packet Switched) Data Rate GPRS multislot class 123, coding scheme CS1-CS4, up to 85.6 kb/s DL/UL EDGE multislot class 123, coding scheme MCS1-MCS9, up to 236.8 kb/s DL/UL CS (Circuit Switched) Data Rate WCDMA CS data up to 64 kb/s DL/UL CS (Circuit Switched) Data Rate GSM CS data up to 9.6 kb/s DL/UL supported in transparent/non transparent mode Table 1: LISA-U2 series UMTS/HSDPA/HSUPA and GSM/GPRS/EDGE characteristics Operation modes I to III are supported on GSM/GPRS networks, with allowing users to define their preferred service from GSM to GPRS. Paging messages for GSM calls may be monitored (optional) during GPRS data transfer in non-coordinating NOM II-III. Device can work simultaneously in Packet Switch and Circuit Switch mode: voice calls are possible while the data connection is active without any interruption in service. Device can be attached to both GPRS and GSM services (i.e. Packet Switch and Circuit Switch mode) using one service at a time. If for example during data transmission an incoming call occurs, the data connection is suspended to allow the voice communication. Once the voice call has terminated, the data service is resumed. GPRS/EDGE multislot class 12 implies a maximum of 4 slots in DL (reception) and 4 slots in UL (transmission) with 5 slots in total UBX-13001118 - R19 Early Production Information System description Page 7 of 175 LISA-U2 series - System Integration Manual 3G Transmission and Receiving: LISA-U2 modules implement 3G High-Speed Uplink Packet Access (HSUPA) category 6. LISA-U200, LISA-U201, LISA-U260 and LISA-U270 modules implement 3G High Speed Downlink Packet Access (HSDPA) category 8. LISA-U230 modules implement the 3G HSDPA category 14. HSUPA and HSDPA categories determine the maximum speed at which data can be respectively transmitted and received. Higher categories allow faster data transfer rates, as indicated in Table 1. The 3G network automatically performs adaptive coding and modulation using a choice of forward error correction code rate and choice of modulation type, to achieve the highest possible data rate and data transmission robustness according to the quality of the radio channel. CellLocate® • • • • • • LISA-U200 FOTA 5.76 7.2 800/850/900 1700/1900/2100 • 1 1 1 14 • • • • • • • • • • •4 • • • • • • LISA-U201 5.76 7.2 800/850/900 1900/2100 • 1 1 1 14 • • • • • • • • • LISA-U230 5.76 21.1 800/850/900 1700/1900/2100 • 1 1 1 14 • • • • • • • • • LISA-U260 5.76 7.2 850/1900 • 1 1 1 14 • • • • • • • • • •4 • LISA-U270 5.76 7.2 900/2100 • 1 1 1 14 • • • • • • • • • •4 • • Automotive AssistNow software • Professional Embedded SSL/TLS • Standard Embedded FTP, HTTP GNSS via Modedm Embedded TCP/UDP 1 14 Rx diversity Jamming detection eCall / ERA-GLONASS Antenna detection 1 1 Grade FW update via serial Network indication Functions FOTA Digital Audio • Analog Audio Audio GPIO 800/850/900 1700/1900/2100 DDC (I2C) USB 5.76 7.2 UART Interfaces GSM/GPRS/EDGE quad-band Bands UMTS/HSPA [MHz] LISA-U200 HSDPA [Mb/s] UMTS HSUPA [Mb/s] Model SPI 2G Transmission and Receiving: LISA-U2 series modules implement GPRS/EGPRS multislot class 12. GPRS and EGPRS multislot classes determine the maximum number of timeslots available for upload and download and thus the speed at which data can be transmitted and received. Higher classes typically allow faster data transfer rates, as indicated in Table 1. The 2G network automatically configures the number of timeslots used for reception or transmission (voice calls take precedence over GPRS/EGPRS traffic) and channel encoding (from Coding Scheme 1 up to Modulation and Coding Scheme 9), performing link adaptation to achieve the highest possible data rate. Table 2 summarizes the interfaces and features provided by LISA-U2 modules. • LISA-U200-52S module product version is approved by SKT Korean network operator. LISA-U200-62S module product version is approved by NTT DoCoMo Japanese network operator LISA-U270-62S and LISA-U270-68S modules product versions are approved and locked for SoftBank Japanese network operator. Table 2: LISA-U2 series summary of interfaces and features Not supported by ”01” product version UBX-13001118 - R19 Early Production Information System description Page 8 of 175 LISA-U2 series - System Integration Manual 1.2 Architecture Duplexers & Filters ANT (U)SIM card RF SWITCH DDC (for GNSS) Switch & Multi band & mode PA PA PMU UART RF Transceiver ANT_DIV SPI 26 MHz Filter Bank 32.768 kHz RF SWITCH Wireless Base-band Processor USB GPIO(s) Transceiver PMU Memory Digital audio (I2S) Vcc (supply) V_BCKP (RTC) Power on Power Management Unit External reset V_INT (I/O) Figure 1: LISA-U2 series block diagram (for available options see Table 2) 1.2.1 Functional blocks LISA-U2 modules consist of the following internal functional blocks: RF section, Baseband and Power Management Unit section. LISA-U2 series RF section A shielding box contains the RF high-power signal circuitry, including: Multimode Single Chain Power Amplifier Module used for 3G HSPA/WCDMA and 2G EDGE/GSM operations Power Management Unit with integrated DC/DC converter for the Power Amplifier Module The RF antenna pad (ANT) is directly connected to the main antenna switch, which dispatches the RF signals according to the active mode. For time-duplex 2G operation, the incoming signal at the active Receiver (RX) slot is applied by the main antenna switch to the duplexer SAW filter bank for out-of-band rejection and then sent to the appropriate receiver port of the RF transceiver. During the allocated Transmitter (TX) slots, the low level signal coming from the RF transceiver is enhanced by the power amplifier and then directed to the antenna pad through the main antenna switch. The 3G transmitter and receiver are active at the same time due to frequencydomain duplex operation. The switch integrated in the main antenna switch connects the antenna port to the duplexer SAW filter bank which separates the TX and RX signal paths. The duplexer itself provides front-end RF filtering for RX band selection while combining the amplified TX signal coming from the power amplifier. A separated shielding box contains all the other analog RF components, including: Antenna Switch and duplexer SAW filter bank for main paths Antenna Switch and SAW filter bank for diversity receiver Up to six-band HSPA/WCDMA and quad-band EDGE/GPRS/GSM transceiver UBX-13001118 - R19 Early Production Information System description Page 9 of 175 LISA-U2 series - System Integration Manual Power Management Unit with integrated DC/DC converter for the Power Amplifier Module Voltage Controlled Temperature Compensated 26 MHz Crystal Oscillator (VC-TCXO) While operating in 3G mode, the RF transceiver performs direct up-conversion and down-conversion of the baseband I/Q signals, with the RF voltage controlled gain amplifier being used to set the uplink TX power. In the downlink path, the integrated LNA enhances the RX sensitivity while discrete inter-stage SAW filters additionally improve the rejection of out-of-band blockers. An internal programmable gain amplifier optimizes the signal levels before delivering to the analog I/Q to baseband for further digital processing. For 2G operations, a constant gain direct conversion receiver with integrated LNAs and highly linear RF quadrature demodulator are used to provide the same I/Q signals to the baseband as well. In transmission mode, the up-conversion is implemented by means of a digital sigma-delta transmitter or polar modulator depending on the modulation to be transmitted. The RF antenna pad for the diversity receiver (ANT_DIV) available on LISA-U230 modules is directly connected to the antenna switch for the diversity receiver, which dispatches the incoming RF signals to the dedicated SAW filter bank for out-of-band rejection and then to the diversity receiver port of the RF transceiver. In all the modes, a fractional-N sigma-delta RF synthesizer and an on-chip 3.296-4.340 GHz voltage controlled oscillator are used to generate the local oscillator signal. The frequency reference to RF oscillators is provided by the 26 MHz VC-TCXO. The same signal is buffered to the baseband as a master reference for clock generation circuits while operating in active mode. LISA-U2 series modulation techniques Modulation techniques related to radio technologies supported by LISA-U2 modules, are listed as follows: GSM GMSK GPRS GMSK EDGE GMSK / 8-PSK WCDMA QPSK HSDPA QPSK / 16-QAM HSUPA QPSK / 16-QAM LISA-U2 series Baseband and Power Management Unit section Another shielding box of LISA-U2 modules includes all the digital circuitry and the power supplies, basically the following functional blocks: Cellular baseband processor, a mixed signal ASIC which integrates: Microprocessor for controller functions, 2G & 3G upper layer software DSP core for 2G Layer 1 and audio processing 3G coprocessor and HW accelerator for 3G Layer 1 control software and routines Dedicated HW for interfaces management Memory system in a Multi-Chip Package (MCP) integrating two devices: NOR flash non-volatile memory DDR SRAM volatile memory Power Management Unit (PMU), used to derive all the system supply voltages from the module supply VCC 32.768 kHz crystal, connected to the Real Time Clock (RTC) oscillator to provide the clock reference in idle or power-off mode UBX-13001118 - R19 Early Production Information System description Page 10 of 175 LISA-U2 series - System Integration Manual 1.3 Pin-out Table 3 lists the pin-out of the LISA-U2 modules, with pins grouped by function. Function Pin Module No Description Remarks Power VCC All 61, 62, 63 I Module supply input Clean and stable supply is required: low ripple and low voltage drop must be guaranteed. Voltage provided has to be always above the minimum limit of the operating range. Consider that there are large current spikes in connected mode, when a GSM call is enabled. VCC pins are internally connected, but all the available pads must be connected to the external supply in order to minimize power loss due to series resistance. See section 1.5.2 GND All 1, 3, 6, 7, N/A 8, 17, 25, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 60, 64, 65, 66, 67, 69, 70, 71, 72, 73, 75, 76 Ground GND pins are internally connected but a good (low impedance) external ground connection can improve RF performance: all GND pins must be externally connected to ground. V_BCKP All I/O Real Time Clock supply input/output V_BCKP = 1.8 V (typical) generated by the module when VCC supply voltage is within valid operating range. See section 1.5.4 V_INT All Digital Interfaces supply output V_INT = 1.8V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. See section 1.5.5 VSIM All 50 SIM supply output VSIM = 1.80 V typical or 2.90 V typical generated by the module according to the SIM card type. See section 1.8 ANT All 68 I/O RF input/output for main Tx/Rx antenna 50 nominal impedance. See section 1.7, section 2.4 and section 2.2.1.1 ANT_DIV LISA-U230 74 RF input for Rx diversity antenna 50 Ω nominal impedance See section 1.7, section 2.4 and section 2.2.1.1 SIM_IO All 48 I/O SIM data Internal 4.7 k pull-up to VSIM. Must meet SIM specifications. See section 1.8 SIM_CLK All 47 SIM clock Must meet SIM specifications. See section 1.8 SIM_RST All 49 SIM reset Must meet SIM specifications. See section 1.8 RF SIM UBX-13001118 - R19 I/O Early Production Information System description Page 11 of 175 LISA-U2 series - System Integration Manual Function Pin Module No I/O Description Remarks SPI SPI_MISO All 57 SPI Data Line Output Module Output: module runs as an SPI slave. Shift data on rising clock edge (CPHA=1). Latch data on falling clock edge (CPHA=1). Idle high. See section 1.9.4 SPI_MOSI All 56 SPI Data Line Input Module Input: module runs as an SPI slave. Shift data on rising clock edge (CPHA=1). Latch data on falling clock edge (CPHA=1). Idle high. Internal active pull-up to V_INT (1.8 V) enabled. See section 1.9.4 SPI_SCLK All 55 SPI Serial Clock Input Module Input: module runs as an SPI slave. Idle low (CPOL=0). Internal active pull-down to GND enabled. See section 1.9.4 SPI_SRDY All 58 SPI Slave Ready Output Module Output: module runs as an SPI slave. Idle low. See section 1.9.4 SPI_MRDY All 59 SPI Master Ready Input Module Input: module runs as an SPI slave. Idle low. Internal active pull- down to GND enabled. See section 1.9.4 SCL All 45 I2C bus clock line Fixed open drain. External pull-up required. See section 1.10 SDA All 46 I/O I2C bus data line Fixed open drain. External pull-up required. See section 1.10 RxD All 16 UART data output Circuit 104 (RxD) in ITU-T V.24. Provide access to the pin for FW update and debugging if the USB interface is connected to the application processor. See section 1.9.2 TxD All 15 UART data input Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT (1.8 V) enabled. Provide access to the pin for FW update and debugging if the USB interface is connected to the application processor. See section 1.9.2 CTS All 14 UART clear to send output Circuit 106 (CTS) in ITU-T V.24. Provide access to the pin for debugging if the USB interface is connected to the application processor. See section 1.9.2 RTS All 13 UART ready to send input Circuit 105 (RTS) in ITU-T V.24. Internal active pull-up to V_INT (1.8 V) enabled. Provide access to the pin for debugging if the USB interface is connected to the application processor. See section 1.9.2 DSR All UART data set ready output Circuit 107 (DSR) in ITU-T V.24. See section 1.9.2 RI All 10 UART ring indicator output Circuit 125 (RI) in ITU-T V.24. See section 1.9.2 DTR All 12 UART data terminal ready input Circuit 108/2 (DTR) in ITU-T V.24. Internal active pull-up to V_INT (1.8 V) enabled. See section 1.9.2 DCD All 11 UART data carrier detect output Circuit 109 (DCD) in ITU-T V.24. See section 1.9.2 DDC UART UBX-13001118 - R19 Early Production Information System description Page 12 of 175 LISA-U2 series - System Integration Manual Function Pin Module No I/O Description Remarks GPIO GPIO1 All 20 I/O GPIO See section 1.12 GPIO2 All 21 I/O GPIO See section 1.12 GPIO3 All 23 I/O GPIO See section 1.12 GPIO4 All 24 I/O GPIO See section 1.12 GPIO5 All 51 I/O GPIO See section 1.12 GPIO6 All 39 I/O GPIO See section 1.12 GPIO7 All 40 I/O GPIO See section 1.12 GPIO8 All 53 I/O GPIO See section 1.12 GPIO9 All 54 I/O GPIO See section 1.12 GPIO10 All 55 I/O GPIO See section 1.12 GPIO11 All 56 I/O GPIO See section 1.12 GPIO12 All 57 I/O GPIO See section 1.12 GPIO13 All 58 I/O GPIO See section 1.12 GPIO14 All 59 I/O GPIO See section 1.12 VUSB_DET All 18 USB detect input Input for VBUS (5 V typical) USB supply sense to enable USB interface. Provide access to the pin for FW update and debugging if the USB interface is not connected to the application processor. See section 1.9.3 USB_D- All 26 I/O USB Data Line D- 90 Ω nominal differential impedance (Z0) 30 Ω nominal common mode impedance (ZCM) Pull-up or pull-down resistors and external series resistors as required by USB 2.0 specifications [7] are part of the USB pad driver and need not be provided externally. Provide access to the pin for FW update and debugging if the USB interface is not connected to the application processor. See section 1.9.3 USB_D+ All 27 I/O USB Data Line D+ 90 Ω nominal differential impedance (Z0) 30 Ω nominal common mode impedance (ZCM) Pull-up or pull-down resistors and external series resistors as required by USB 2.0 specifications [7] are part of the USB pad driver and need not be provided externally. Provide access to the pin for FW update and debugging if the USB interface is not connected to the application processor. See section 1.9.3 PWR_ON All 19 Power-on input PWR_ON pin has high input impedance. Do not keep floating in noisy environment: external pull-up required. See section 1.6.1 RESET_N All 22 External reset input Internal 10 kΩ pull-up to V_BCKP. See section 1.6.3 USB System UBX-13001118 - R19 Early Production Information System description Page 13 of 175 LISA-U2 series - System Integration Manual Function Pin Module No I/O Description Remarks Digital Audio I2S_CLK All 43 I/O First I2S clock Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S_RXD All 44 First I2S receive data Internal active pull-down to GND enabled. Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S_TXD All 42 First I2S transmit data Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S_WA All 41 I/O First I2S word alignment Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S1_CLK All 53 I/O Second I2S clock Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S1_RXD All 39 Second I2S receive data Internal active pull-down to GND enabled. Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S1_TXD All 40 Second I2S transmit data Check device specifications to ensure compatibility to module supported modes. See section 1.11. I2S1_WA All 54 I/O Second I2S word alignment Check device specifications to ensure compatibility to module supported modes. See section 1.11. CODEC_CLK All 52 Clock output Digital clock output for external audio codec See section 1.11. RSVD All N/A RESERVED pin This pin must be connected to ground See section 1.13 RSVD LISA-U200 LISA-U201 LISA-U260 LISA-U270 74 N/A RESERVED pin Do not connect See section 1.13 Reserved Table 3: LISA-U2 modules pin definition, grouped by function UBX-13001118 - R19 Early Production Information System description Page 14 of 175 LISA-U2 series - System Integration Manual 1.4 Operating modes LISA-U2 series modules have several operating modes. The operating modes are defined in Table 4 and described in details in Table 5, providing general guidelines for operation. General Status Operating Mode Definition Power-down Not-Powered Mode Power-Off Mode VCC supply not present or below operating range: module is switched off. VCC supply within operating range and module is switched off. Normal Operation Idle-Mode Active-Mode Module processor core runs with 32 kHz as reference oscillator. Module processor core runs with 26 MHz as reference oscillator. Connected-Mode Voice or data call enabled and processor core runs with 26 MHz as reference oscillator. Table 4: Module operating modes definition Operating Mode Description Transition between operating modes Not-Powered Module is switched off. Application interfaces are not accessible. Internal RTC timer operates only if a valid voltage is applied to V_BCKP pin. When VCC supply is removed, the module enters not-powered mode. When in not-powered mode, the module cannot be switched on by a low pulse on PWR_ON input, by a rising edge on RESET_N input, or by a preset RTC alarm. When in not-powered mode, the module can be switched on applying VCC supply (see 1.6.1) so that the module switches from not-powered to active-mode. Power-Off Module is switched off: normal shutdown by an appropriate power-off event (see 1.6.2). Application interfaces are not accessible. Only the internal RTC timer in operation. When the module is switched off by an appropriate power-off event (see 1.6.2), the module enters power-off mode from active-mode. When in power-off mode, the module can be switched on by a low pulse on PWR_ON input, by a rising edge on RESET_N input, or by a preset RTC alarm (see 1.6.1): module switches from power-off to active-mode. When VCC supply is removed, the module switches from power-off mode to not-powered mode. Idle Application interfaces are disabled: the module does not accept data signals from an external device connected to the module. The module automatically enters idle-mode whenever possible if power saving is enabled by AT+UPSV (see u-blox AT Commands Manual [2]), reducing current consumption (see 1.5.3.3). If HW flow control is enabled (default setting) and AT+UPSV=1 or AT+UPSV=3 has been set, the UART CTS line indicates when the UART is enabled (see 1.9.2.2, 1.9.2.3). If HW flow control is disabled by AT&K0, the UART CTS line is fixed to ON state (see 1.9.2.2). Power saving configuration is not enabled by default: it can be enabled by AT+UPSV (see the u-blox AT Commands Manual [2]). The module automatically switches from active-mode to idle-mode whenever possible if power saving is enabled (see 1.5.3.3, 1.9.2.3, 1.9.3.2, 1.9.4.2 and u-blox AT Commands Manual [2], AT+UPSV). The module wakes up from idle-mode to active-mode in these events: Automatic periodic monitoring of the paging channel for the paging block reception according to network conditions (see 1.5.3.3, 1.9.2.3) Automatic periodic enable of the UART interface to receive and send data, if AT+UPSV=1 has been set (see 1.9.2.3) RTC alarm occurs (see u-blox AT Commands Manual [2], AT+CALA) Data received on UART interface, if HW flow control has been disabled by AT&K0 and AT+UPSV=1 has been set (see 1.9.2.3) RTS input set ON by the DTE if HW flow control has been disabled by AT&K0 and AT+UPSV=2 has been set (see 1.9.2.3) DTR input set ON by DTE if AT+UPSV=3 has been set (see 1.9.2.3) USB detection, applying 5 V (typ.) to VUSB_DET input (see 1.9.3) The connected USB host forces a remote wakeup of the module as USB device (see 1.9.3) The connected SPI master indicates by the SPI_MRDY input signal that it is ready for transmission or reception (see 1.9.4) The connected u-blox GNSS receiver indicates by the GPIO3 pin that it is ready to send data (see 1.10, 1.12) UBX-13001118 - R19 Early Production Information System description Page 15 of 175 LISA-U2 series - System Integration Manual Operating Mode Description Transition between operating modes Active The module is ready to accept data signals from an external device unless power saving configuration is enabled by AT+UPSV (see sections 1.9.2.3, 1.9.3.2, 1.9.4.2 and u-blox AT Commands Manual [2]). When the module is switched on by an appropriate power-on event (see 1.6.1), the module enters active-mode from not-powered or power-off mode. If power saving configuration is enabled by the AT+UPSV command, the module automatically switches from active to idle-mode whenever possible and the module wakes up from idle to active-mode in the events listed above (see the idle to active transition description). When a voice call or a data call is initiated, the module switches from active-mode to connected-mode. Connected A voice call or a data call is in progress. When a voice or a data call is enabled, the application interfaces are kept enabled and the module is prepared to accept data from an external device unless power saving configuration is enabled by AT+UPSV (see 1.9.2.3, 1.9.3.2, 1.9.4.2 and u-blox AT Commands Manual [2]). When a voice call or a data call is initiated, the module enters connected-mode from active-mode. If power saving configuration is enabled by the AT+UPSV command, the module automatically switches from connected to idle-mode whenever possible in case of PSD data call with internal context activation, and then it wakes up from idle to connected mode in the events listed above (see the idle to active transition description). When a voice call or a data call is terminated, the module returns to the active-mode. Table 5: Module operating modes description Figure 2 describes the transition between the different operating modes. Not powered Remove VCC Switch ON: • Apply VCC Power off Switch ON: • PWR_ON • RESET_N • RTC Alarm Switch OFF: • AT+CPWROFF • PWR_ON Incoming/outgoing call or other dedicated device network communication Connected If power saving is enabled and there is no activity for a defined time interval Active Call terminated, communication dropped Idle Any wake up event described in the module operating modes summary table above Figure 2: Operating modes transition UBX-13001118 - R19 Early Production Information System description Page 16 of 175 LISA-U2 series - System Integration Manual 1.5 Power management 1.5.1 Power supply circuit overview LISA-U2 series modules feature a power management concept optimized for the most efficient use of supplied power. This is achieved by hardware design utilizing a power efficient circuit topology (Figure 3), and by power management software controlling the module’s power saving mode. 2G/3G Power Amplifier(s) 2G/3G PA PMU Memory NOR Flash Transceiver PMU RF Transceiver DDR SRAM Linear LDO VCC 61 VCC 62 VCC 63 Linear LDO Switching Step-Down I/O Switching Step-Down CORE Linear LDO Analog Linear LDO SIM Linear LDO RTC 5 x 10 µF Power Management Unit V_INT V_BCKP VSIM 50 EBU 22 µF 220 nF Baseband Processor 220 nF Figure 3: LISA-U2 series power management simplified block diagram UBX-13001118 - R19 Early Production Information System description Page 17 of 175 LISA-U2 series - System Integration Manual Pins with supply function are reported in Table 6, Table 12 and Table 15. LISA-U2 series modules must be supplied via the VCC pins. There is only one main power supply input, available on the three VCC pins that must be all connected to the external power supply. The VCC pins are directly connected to the RF power amplifiers and to the integrated Power Management Unit (PMU) within the module: all supply voltages needed by the module are generated from the VCC supply by integrated voltage regulators. V_BCKP is the Real Time Clock (RTC) supply. When the VCC voltage is within the valid operating range, the internal PMU supplies the Real Time Clock and the same supply voltage will be available to the V_BCKP pin. If the VCC voltage is under the minimum operating limit (for example, during not powered mode), the Real Time Clock can be externally supplied via the V_BCKP pin (see section 1.5.4). When a 1.8 V or a 3 V SIM card type is connected, LISA-U2 series modules automatically supply the SIM card via the VSIM pin. Activation and deactivation of the SIM interface with automatic voltage switch from 1.8 to 3 V is implemented, in accordance to the ISO-IEC 7816-3 specifications. The same voltage domain used internally to supply the digital interfaces is also available on the V_INT pin, to allow more economical and efficient integration of the LISA-U2 series modules in the final application. The integrated Power Management Unit also provides the control state machine for system start up and system reset control. 1.5.2 Module supply (VCC) The LISA-U2 series modules must be supplied through the VCC pins by a DC power supply. Voltages must be stable: during operation, the current drawn from VCC can vary by some orders of magnitude, especially due to surging consumption profile of the GSM system (described in the section 1.5.3). It is important that the system power supply circuit is able to support peak power (see LISA-U2 series Data Sheet [1] for the detailed specifications). Name Description Remarks VCC Module power supply input GND Ground VCC pins are internally connected, but all the available pads must be connected to the external supply in order to minimize the power loss due to series resistance. Clean and stable supply is required: low ripple and low voltage drop must be guaranteed. Voltage provided must always be above the minimum limit of the operating range. Consider that during a GSM call there are large current spikes in connected mode. GND pins are internally connected but a good (low impedance) external ground can improve RF performance: all available pads must be connected to ground. Table 6: Module supply pins VCC pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level can be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point. The voltage provided to the VCC pins must be within the normal operating range limits as specified in the LISA-U2 series Data Sheet [1]. Complete functionality of the module is only guaranteed within the specified minimum and maximum VCC voltage normal operating range. UBX-13001118 - R19 Early Production Information System description Page 18 of 175 LISA-U2 series - System Integration Manual The module cannot be switched on if the VCC voltage value is below the specified normal operating range minimum limit. Ensure that the input voltage at VCC pins is above the minimum limit of the normal operating range for more than 3 s after the start of the module switch-on sequence. When LISA-U2 series modules are in operation, the voltage provided to VCC pins can go outside the normal operating range limits but must be within the extended operating range limits specified in LISA-U2 series Data Sheet [1]. Occasional deviations from the ETSI specifications may occur when the input voltage at VCC pins is outside the normal operating range and is within the extended operating range. LISA-U2 series modules switch off when VCC voltage value drops below the specified extended operating range minimum limit: ensure that the input voltage at VCC pins never drops below the minimum limit of the extended operating range when the module is switched on, not even during a GSM transmit burst, where the current consumption can rise up to maximum peaks of 2.5 A in case of a mismatched antenna load. Operation above the normal operating range maximum limit is not recommended and extended exposure beyond it may affect device reliability. Stress beyond the VCC absolute maximum ratings can cause permanent damage to the module: if necessary, voltage spikes beyond VCC absolute maximum ratings must be restricted to values within the specified limits by using appropriate protection. When designing the power supply for the application, pay specific attention to power losses and transients. The DC power supply must be able to provide a voltage profile to the VCC pins with the following characteristics: Voltage drop during transmit slots must be lower than 400 mV No undershoot or overshoot at the start and at the end of transmit slots Voltage ripple during transmit slots must be minimized: lower than 70 mVpp if fripple ≤ 200 kHz lower than 10 mVpp if 200 kHz < fripple ≤ 400 kHz lower than 2 mVpp if fripple > 400 kHz Voltage overshoot ripple 3.8 V (typ) drop ripple RX slot unused unused slot slot TX slot undershoot unused unused slot slot GSM frame 4.615 ms (1 frame = 8 slots) MON slot unused slot RX slot unused unused slot slot TX slot unused unused slot slot GSM frame 4.615 ms (1 frame = 8 slots) MON slot unused slot Time Figure 4: Description of the VCC voltage profile versus time during a GSM call UBX-13001118 - R19 Early Production Information System description Page 19 of 175 LISA-U2 series - System Integration Manual Any degradation in power supply performance (due to losses, noise or transients) will directly affect the RF performance of the module since the single external DC power source indirectly supplies all the digital and analog interfaces, and also directly supplies the RF power amplifier (PA). The voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms. This VCC slope allows a proper switch on of the module when the voltage rises to the VCC normal operating range from a voltage of less than 2.25 V. If the external supply circuit cannot raise the VCC voltage from 2.5 V to 3.2 V within 1 ms, the RESET_N pin should be kept low during VCC rising edge, so that the module will switch on releasing the RESET_N pin when the VCC voltage stabilizes at its nominal value within the normal operating range. 1.5.2.1 VCC application circuits LISA-U2 series modules must be supplied through the VCC pins by a proper DC power supply, which can be selected according to the application requirements (see Figure 5) between the different possible supply sources types, which most common ones are the following: Switching regulator Low Drop-Out (LDO) linear regulator Rechargeable Lithium-ion (Li-Ion) or Lithium-ion polymer (Li-Pol) battery Primary (disposable) battery Main Supply Available? No, portable device Battery Li-Ion 3.7 V Yes, always available Main Supply Voltage > 5V? No, less than 5 V Yes, greater than 5 V Linear LDO Regulator Switching Step-Down Regulator Figure 5: VCC supply concept selection The switching step-down regulator is the typical choice when the available primary supply source has a nominal voltage much higher (e.g. greater than 5 V) than the LISA-U2 series modules operating supply voltage. The use of switching step-down provides the best power efficiency for the overall application and minimizes current drawn from the main supply source. The use of an LDO linear regulator becomes convenient for a primary supply with a relatively low voltage (e.g. less than 5 V). In this case the typical 90% efficiency of the switching regulator will diminish the benefit of voltage step-down and no true advantage will be gained in input current savings. On the opposite side, linear regulators are not recommended for high voltage step-down as they will dissipate a considerable amount of energy in thermal power. If LISA-U2 series modules are deployed in a mobile unit where no permanent primary supply source is available, then a battery will be required to provide VCC. A standard 3-cell Li-Ion or Li-Pol battery pack directly connected to VCC is the usual choice for battery-powered devices. During charging, batteries with Ni-MH chemistry typically reach a maximum voltage that is above the maximum rating for VCC, and should therefore be avoided. The use of primary (not rechargeable) battery is uncommon, since the most cells available are seldom capable of delivering the burst peak current for a GSM call due to high internal resistance. Keep in mind that the use of batteries requires the implementation of a suitable charger circuit (not included in LISA-U2 series modules). The charger circuit should be designed in order to prevent over-voltage on VCC beyond the upper limit of the absolute maximum rating. The usage of more than one DC supply at the same time should be carefully evaluated: depending on the supply source characteristics, different DC supply systems can result as mutually exclusive. UBX-13001118 - R19 Early Production Information System description Page 20 of 175 LISA-U2 series - System Integration Manual The usage of a regulator or a battery not able to withstand the maximum VCC peak current consumption stated in LISA-U2 series Data Sheet [1] is generally not recommended. However, if the selected regulator or battery is not able to withstand the maximum VCC peak current, it must be able to withstand at least the maximum average current consumption value specified in the module data sheet Error! Reference source not found.. The additional energy required by the module during a GSM/GPRS Tx slot (when in the worst case the current consumption can rise up to 2.5 A, as described in section 1.5.3.1) can be provided by an appropriate bypass tank capacitor or supercapacitor with very large capacitance and very low ESR placed close to the module VCC pins. Depending on the actual capability of the selected regulator or battery, the required capacitance can be considerably larger than 1 mF and the required ESR can be in the range of few tens of m. Carefully evaluate the implementation of this solution since aging and temperature conditions significantly affect the actual capacitor characteristics. The following sections highlight some design aspects for each of the supplies listed above. Switching regulator The characteristics of the switching regulator connected to VCC pins should meet the following requirements: Power capability: the switching regulator with its output circuit must be capable of providing a voltage value to the VCC pins within the specified operating range and must be capable of delivering 2.5 A current pulses with 1/8 duty cycle to the VCC pins Low output ripple: the switching regulator together with its output circuit must be capable of providing a clean (low noise) VCC voltage profile High switching frequency: for best performance and for smaller applications select a switching frequency ≥ 600 kHz (since L-C output filter is typically smaller for high switching frequency). The use of a switching regulator with a variable switching frequency or with a switching frequency lower than 600 kHz must be carefully evaluated since this can produce noise in the VCC voltage profile and therefore negatively impact GSM modulation spectrum performance. An additional L-C low-pass filter between the switching regulator output to VCC supply pins can mitigate the ripple on VCC, but adds extra voltage drop due to resistive losses on series inductors PWM mode operation: select preferably regulators with Pulse Width Modulation (PWM) mode. While in connected mode Pulse Frequency Modulation (PFM) mode and PFM/PWM mode transitions must be avoided to reduce the noise on the VCC voltage profile. Switching regulators able to switch between low ripple PWM mode and high efficiency burst or PFM mode can be used, provided the mode transition occurs when the module changes status from idle/active mode to connected mode (where current consumption increases to a value greater than 100 mA): it is permissible to use a regulator that switches from the PWM mode to the burst or PFM mode at an appropriate current threshold (e.g. 60 mA) Output voltage slope: the use of the soft start function provided by some voltage regulator must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module Figure 6 and the components listed in Table 7 show an example of a high reliability power supply circuit, where the module VCC is supplied by a step-down switching regulator capable of delivering 2.5 A current pulses with low output ripple and with fixed switching frequency in PWM mode operation greater than 1 MHz. The use of a switching regulator is suggested when the difference from the available supply rail to the VCC value is high: switching regulators provide good efficiency transforming a 12 V supply to the typical 3.8 V value of the VCC supply. UBX-13001118 - R19 Early Production Information System description Page 21 of 175 LISA-U2 series - System Integration Manual 12V LISA-U2 series VIN R2 C1 C2 BD 1 BOOST 2 5 RUN R1 C3 C4 9 VC 10 RT 7 PG R3 SW 61 VCC 62 VCC 63 VCC C6 L1 D1 U1 C8 FB 8 SYNC GND 11 C5 C7 R4 R5 GND Figure 6: Suggested schematic design for the VCC voltage supply application circuit using a step-down regulator Reference Description Part Number - Manufacturer C1 10 µF Capacitor Ceramic X7R 5750 15% 50 V C5750X7R1H106MB - TDK C2 C3 10 nF Capacitor Ceramic X7R 0402 10% 16 V 680 pF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 - Murata GRM155R71H681KA01 - Murata C4 C5 22 pF Capacitor Ceramic COG 0402 5% 25 V 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM1555C1H220JZ01 - Murata GRM155R71C103KA01 - Murata C6 C7 470 nF Capacitor Ceramic X7R 0603 10% 25 V 22 µF Capacitor Ceramic X5R 1210 10% 25 V GRM188R71E474KA12 - Murata GRM32ER61E226KE15 - Murata C8 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 mΩ T520D337M006ATE045 - KEMET D1 L1 Schottky Diode 40 V 3 A 10 µH Inductor 744066100 30% 3.6 A MBRA340T3G - ON Semiconductor 744066100 - Wurth Electronics R1 R2 470 kΩ Resistor 0402 5% 0.1 W 15 kΩ Resistor 0402 5% 0.1 W 2322-705-87474-L - Yageo 2322-705-87153-L - Yageo R3 R4 22 kΩ Resistor 0402 5% 0.1 W 390 kΩ Resistor 0402 1% 0.063 W 2322-705-87223-L - Yageo RC0402FR-07390KL - Yageo R5 100 kΩ Resistor 0402 5% 0.1 W 2322-705-70104-L - Yageo U1 Step Down Regulator MSOP10 3.5 A 2.4 MHz LT3972IMSE#PBF - Linear Technology Table 7: Suggested components for the VCC voltage supply application circuit using a step-down regulator Figure 7 and the components listed in Table 8 show an example of a low cost power supply circuit, where the VCC module supply is provided by a step-down switching regulator capable of delivering 2.5 A current pulses, transforming a 12 V supply input. 12V LISA-U2 series VCC OUT 1 3 INH L1 D1 C1 6 FSW C6 R5 U1 2 SYNC GND R3 C3 FB 5 COMP 4 R1 61 VCC 62 VCC 63 VCC C4 R4 C2 R2 C5 GND Figure 7: Suggested low cost solution for the VCC voltage supply application circuit using step-down regulator UBX-13001118 - R19 Early Production Information System description Page 22 of 175 LISA-U2 series - System Integration Manual Reference Description Part Number - Manufacturer C1 22 µF Capacitor Ceramic X5R 1210 10% 25 V GRM32ER61E226KE15 – Murata C2 100 µF Capacitor Tantalum B_SIZE 20% 6.3V 15m T520B107M006ATE015 – Kemet C3 C4 5.6 nF Capacitor Ceramic X7R 0402 10% 50 V 6.8 nF Capacitor Ceramic X7R 0402 10% 50 V GRM155R71H562KA88 – Murata GRM155R71H682KA88 – Murata C5 C6 56 pF Capacitor Ceramic C0G 0402 5% 50 V 220 nF Capacitor Ceramic X7R 0603 10% 25 V GRM1555C1H560JA01 – Murata GRM188R71E224KA88 – Murata D1 Schottky Diode 25V 2 A STPS2L25 – STMicroelectronics L1 5.2 µH Inductor 30% 5.28A 22 m MSS1038-522NL – Coilcraft R1 4.7 k Resistor 0402 1% 0.063 W RC0402FR-074K7L – Yageo R2 910 Resistor 0402 1% 0.063 W RC0402FR-07910RL – Yageo R3 82 Resistor 0402 5% 0.063 W RC0402JR-0782RL – Yageo R4 8.2 k Resistor 0402 5% 0.063 W RC0402JR-078K2L – Yageo R5 39 k Resistor 0402 5% 0.063 W Step-Down Regulator 8-VFQFPN 3 A 1 MHz RC0402JR-0739KL – Yageo U1 L5987TR – ST Microelectronics Table 8: Suggested components for low cost solution VCC voltage supply application circuit using a step-down regulator Low Drop-Out (LDO) linear regulator The characteristics of the LDO linear regulator connected to the VCC pins should meet the following requirements: Power capabilities: the LDO linear regulator with its output circuit must be capable of providing a proper voltage value to the VCC pins and of delivering 2.5 A current pulses with 1/8 duty cycle Power dissipation: the power handling capability of the LDO linear regulator must be checked to limit its junction temperature to the maximum rated operating range (i.e. check the voltage drop from the max input voltage to the min output voltage to evaluate the power dissipation of the regulator) Output voltage slope: the use of the soft start function provided by some voltage regulators must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module Figure 8 and the components listed in Table 9 show an example of a power supply circuit, where the VCC module supply is provided by an LDO linear regulator capable of delivering 2.5 A current pulses, with proper power handling capability. The use of a linear regulator is suggested when the difference from the available supply rail and the VCC value is low: linear regulators provide high efficiency when transforming a 5 V supply to a voltage value within the module VCC normal operating range. It is recommended to configure the LDO linear regulator so that it generates a voltage supply value slightly below the maximum limit of the module VCC normal operating range (e.g. ~4.1 V as in the circuit described in Figure 8 and Table 9). This reduces the power on the linear regulator and improves the thermal design of the supply circuit. UBX-13001118 - R19 Early Production Information System description Page 23 of 175 LISA-U2 series - System Integration Manual LISA-U2 series 5V IN OUT 61 VCC 62 VCC 63 VCC U1 C1 R1 R2 SHDN ADJ C2 C3 GND GND R3 Figure 8: Suggested schematic design for the VCC voltage supply application circuit using an LDO linear regulator Reference Description Part Number - Manufacturer C1, C2 C3 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 mΩ GRM188R60J106ME47 - Murata T520D337M006ATE045 - KEMET R1 47 kΩ Resistor 0402 5% 0.1 W RC0402JR-0747KL - Yageo Phycomp R2 R3 9.1 kΩ Resistor 0402 5% 0.1 W 3.9 kΩ Resistor 0402 5% 0.1 W RC0402JR-079K1L - Yageo Phycomp RC0402JR-073K9L - Yageo Phycomp U1 LDO Linear Regulator ADJ 3.0 A LT1764AEQ#PBF - Linear Technology Table 9: Suggested components for VCC voltage supply application circuit using an LDO linear regulator Rechargeable Li-Ion or Li-Pol battery Rechargeable Li-Ion or Li-Pol batteries connected to the VCC pins should meet the following requirements: Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its output circuit must be capable of delivering 2.5 A current pulses with 1/8 duty-cycle to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption to VCC pins. The maximum pulse discharge current and the maximum DC discharge current are not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 400 mV during transmit bursts Primary (disposable) battery The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following requirements: Maximum pulse and DC discharge current: the non-rechargeable battery with its output circuit must be capable of delivering 2.5 A current pulses with 1/8 duty-cycle to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption at the VCC pins. The maximum pulse and the maximum DC discharge current is not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 400 mV during transmit bursts UBX-13001118 - R19 Early Production Information System description Page 24 of 175 LISA-U2 series - System Integration Manual Additional recommendations for the VCC supply application circuits To reduce voltage drops, use a low impedance power source. The resistance of the power supply lines (connected to the VCC and GND pins of the module) on the application board and battery pack should also be considered and minimized: cabling and routing must be as short as possible in order to minimize power losses. It is recommended to properly connect all three VCC pins and all twenty GND pins of the module to the supply source to minimize series resistance losses. To avoid voltage drop undershoot and overshoot at the start and end of a transmit burst during a GSM call (when current consumption on the VCC supply can rise up to as much as 2.5 A in the worst case), place a bypass capacitor with large capacitance (more than 100 µF) and low ESR near the VCC pins, for example: 330 µF capacitance, 45 mΩ ESR (e.g. KEMET T520D337M006ATE045, Tantalum Capacitor) The use of very large capacitors (i.e. greater then 1000 µF) on the VCC line and the use of the soft start function provided by some voltage regulators must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch on of the module. To reduce voltage ripple and noise, which should improve RF performance if the application device integrates an internal antenna, place the following series ferrite bead and bypass capacitors near the VCC pins of the module: Ferrite bead for GHz band noise (e.g. Murata BLM18EG221SN1) as close as possible to the VCC pins of the module, implementing the circuit described in Figure 9, to filter EMI in all the GSM / UMTS bands. 68 pF capacitor with Self-Resonant Frequency in the 800/900 MHz range (e.g. Murata GRM1555C1H680J) at the VCC line where it narrows close to the module (see Figure 9), to filter EMI in lower bands 15 pF capacitor with Self-Resonant Frequency in 1800/1900 MHz range (e.g. Murata GRM1555C1H150J) at the VCC line where it narrows close to the module (see Figure 9), to filter EMI in higher bands 10 nF capacitor (e.g. Murata GRM155R71C103K) to filter digital logic noise from clocks and data sources 100 nF capacitor (e.g. Murata GRM155R61A104K) to filter digital logic noise from clocks and data sources Figure 9 shows the complete configuration, but keep in mind that the mounting of each single component depends on the application design. It is highly recommended to provide the series ferrite bead and all the VCC bypass capacitors as described in Figure 9 and Table 10 if the application device integrates an internal antenna. LISA-U2 series Capacitor with SRF ~900 MHz 3V8 VCC VCC VCC 61 62 Ferrite Bead for GHz noise FB1 63 C1 C2 C3 C4 C5 C5 Capacitor with SRF ~1900 MHz GND plane C1 C2 C3 C4 FB1 LISA-U series VCC line GND Figure 9: Suggested schematic and layout design for the VCC line; highly recommended when using an integrated antenna Reference Description Part Number - Manufacturer C1 68 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H680JA01 - Murata C2 C3 15 pF Capacitor Ceramic C0G 0402 5% 50 V 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM1555C1H150JA01 - Murata GRM155R71C103KA01 - Murata C4 C5 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C104KA01 - Murata T520D337M006ATE045 - KEMET FB1 Chip Ferrite Bead EMI Filter for GHz Band Noise 220 at 100 MHz, 260 at 1 GHz, 2000 mA 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 m BLM18EG221SN1 - Murata Table 10: Suggested components for VCC circuit close to module’ pins; highly recommended when using an integrated antenna UBX-13001118 - R19 Early Production Information System description Page 25 of 175 LISA-U2 series - System Integration Manual External battery charging application circuit LISA-U2 series modules do not have an on-board charging circuit. An example of a battery charger design, suitable for applications that are battery powered with a Li-Ion (or Li-Polymer) cell, is provided in Figure 10. In the application circuit, a rechargeable Li-Ion (or Li-Polymer) battery cell, that features proper pulse and DC discharge current capabilities and proper DC series resistance, is directly connected to the VCC supply input of LISA-U2 series module. Battery charging is completely managed by the STMicroelectronics L6924U Battery Charger IC that, from a USB power source (5.0 V typ.), charges as a linear charger the battery, in three phases: Pre-charge constant current (active when the battery is deeply discharged): the battery is charged with a low current, set to 10% of the fast-charge current Fast-charge constant current: the battery is charged with the maximum current, configured by the value of an external resistor to a value suitable for USB power source (~500 mA) Constant voltage: when the battery voltage reaches the regulated output voltage (4.2 V), the L6924U starts to reduce the current until the charge termination is done. The charging process ends when the charging current reaches the value configured by an external resistor to ~15 mA or when the charging timer reaches the value configured by an external capacitor to ~9800 s Using a battery pack with an internal NTC resistor, the L6924U can monitor the battery temperature to protect the battery from operating under unsafe thermal conditions. Alternatively the L6924U, providing input voltage range up to 12 V, can charge from an AC wall adapter. When a current-limited adapter is used, it can operate in quasi-pulse mode, reducing power dissipation. Li-Ion/Li-Polymer Battery Charger IC LISA-U2 series 5V0 USB Supply VIN VOUT FB1 VINSNS VOSNS MODE R1 R2 R3 VREF ISEL C3 IUSB IAC Li-Ion/Li-Pol Battery Pack R4 61 VCC 62 VCC 63 VCC C4 TH θ IEND C5 C6 C7 C8 C9 TPRG SD C1 B1 GND GND C2 U1 D1 Figure 10: Li-Ion (or Li-Polymer) battery charging application circuit Reference Description Part Number - Manufacturer B1 Li-Ion (or Li-Polymer) battery pack with 470 NTC Various manufacturer C1, C4 C2, C6 1 µF Capacitor Ceramic X7R 0603 10% 16 V 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM188R71C105KA12 - Murata GRM155R71C103KA01 - Murata C3 1 nF Capacitor Ceramic X7R 0402 10% 50 V GRM155R71H102KA01 - Murata C5 T520D337M006ATE045 - KEMET C7 330 µF Capacitor Tantalum D_SIZE 6.3 V 45 m 100 nF Capacitor Ceramic X7R 0402 10% 16 V C8 C9 15 pF Capacitor Ceramic C0G 0402 5% 50 V 68 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H150JA01 - Murata GRM1555C1H680JA01 - Murata D1 FB1 Low Capacitance ESD Protection Chip Ferrite Bead EMI Filter for GHz Band Noise 220 at 100 MHz, 260 at 1 GHz, 2000 mA USB0002RP or USB0002DP - AVX BLM18EG221SN1 - Murata R1, R2 24 k Resistor 0402 5% 0.1 W RC0402JR-0724KL - Yageo Phycomp R3 3.3 k Resistor 0402 5% 0.1 W RC0402JR-073K3L - Yageo Phycomp R4 1.0 k Resistor 0402 5% 0.1 W Single Cell Li-Ion (or Li-Polymer) Battery Charger IC for USB port and AC Adapter RC0402JR-071K0L - Yageo Phycomp U1 GRM155R61A104KA01 - Murata L6924U - STMicroelectronics Table 11: Suggested components for Li-Ion (or Li-Polymer) battery charging application circuit UBX-13001118 - R19 Early Production Information System description Page 26 of 175 LISA-U2 series - System Integration Manual 1.5.3 Current consumption profiles During operation, the current drawn by the LISA-U2 series modules through the VCC pins can vary by several orders of magnitude. This ranges from the high peak of current consumption during GSM transmitting bursts at maximum power level in 2G connected mode, to continuous high current drawn in UMTS connected mode, to the low current consumption during power saving in idle-mode. 1.5.3.1 2G connected mode When a GSM call is established, the VCC consumption is determined by the current consumption profile typical of the GSM transmitting and receiving bursts. The current consumption peak during a transmission slot is strictly dependent on the transmitted power, which is regulated by the network. If the module is transmitting in GSM talk mode in the GSM 850 or in the E-GSM 900 band and at the maximum RF power control level (approximately 2 W or 33 dBm in the allocated transmit slot/burst) the current consumption can reach up to 2500 mA (with a highly unmatched antenna) for 576.9 µs (width of the transmit slot/burst) with a periodicity of 4.615 ms (width of 1 frame = 8 slots/burst), so with a 1/8 duty cycle according to GSM TDMA (Time Division Multiple Access). If the module is in GSM connected mode in the DCS 1800 or in the PCS 1900 band, the current consumption figures are lower than the one in the GSM 850 or in the E-GSM 900 band, due to 3GPP transmitter output power specifications (see LISA-U2 series Data Sheet [1]). During a GSM call, current consumption is in the order of 60-130 mA in receiving or in monitor bursts and is about 10-40 mA in the inactive unused bursts (low current period). The more relevant contribution to determine the average current consumption is set by the transmitted power in the transmit slot. An example of current consumption profile of the data module in GSM talk mode is shown in Figure 11. Current [A] 2.5 2.0 1.5 Peak current depends on TX power and actual antenna load 1.0 0.5 0.0 RX slot unused unused slot slot TX slot unused unused slot slot MON slot unused slot RX slot unused unused slot slot GSM frame 4.615 ms (1 frame = 8 slots) TX slot unused unused slot slot MON slot unused slot Time [ms] GSM frame 4.615 ms (1 frame = 8 slots) Figure 11: VCC current consumption profile versus time during a GSM call (1 TX slot, 1 RX slot) UBX-13001118 - R19 Early Production Information System description Page 27 of 175 LISA-U2 series - System Integration Manual When a GPRS connection is established there is a different VCC current consumption profile also determined by the transmitting and receiving bursts. In contrast to a GSM call, during a GPRS connection more than one slot can be used to transmit and/or more than one slot can be used to receive. The transmitted power depends on network conditions, which set the peak current consumption, but following the GPRS specifications the maximum transmitted RF power is reduced if more than one slot is used to transmit, so the maximum peak of current consumption is not as high as can be in case of a GSM call. If the module transmits in GPRS class 12 connected mode in the GSM 850 or in the E-GSM 900 band at the maximum power control level, the current consumption can reach up to 1600 mA (with unmatched antenna). This happens for 2.307 ms (width of the 4 transmit slots/bursts) with a periodicity of 4.615 ms (width of 1 frame = 8 slots/bursts), so with a 1/2 duty cycle, according to GSM TDMA. If the module is in GPRS connected mode in the DCS 1800 or in the PCS 1900 band, the current consumption figures are lower than in the GSM 850 or in the E-GSM 900 band, due to 3GPP transmitter output power specifications (see LISA-U2 series Data Sheet [1]). Figure 12 reports the current consumption profiles in GPRS class 12 connected mode, in the GSM 850 or in the E-GSM 900 band, with 4 slots used to transmit and 1 slot used to receive. Current [A] 2.5 2.0 1.5 Peak current depends on TX power and actual antenna load 1.0 0.5 0.0 RX slot unused slot TX slot TX slot TX slot TX slot GSM frame 4.615 ms (1 frame = 8 slots) MON slot unused slot RX slot unused slot TX slot TX slot TX slot TX slot MON slot unused slot Time [ms] GSM frame 4.615 ms (1 frame = 8 slots) Figure 12: VCC current consumption profile versus time during a GPRS/EDGE connection (4TX slots, 1 RX slot) In case of EDGE connections the VCC current consumption profile is very similar to the GPRS current profile, so the image shown in Figure 12, representing the current consumption profile in GPRS class 12 connected mode, is valid for the EDGE class 12 connected mode as well. UBX-13001118 - R19 Early Production Information System description Page 28 of 175 LISA-U2 series - System Integration Manual 1.5.3.2 3G connected mode During a 3G connection, the module can transmit and receive continuously due to the Frequency Division Duplex (FDD) mode of operation with the Wideband Code Division Multiple Access (WCDMA). The current consumption depends again on output RF power, which is always regulated by network commands. These power control commands are logically divided into a slot of 666 µs, thus the rate of power change can reach a maximum rate of 1.5 kHz. There are no high current peaks as in the 2G connection, since transmission and reception are continuously enabled due to FDD WCDMA implemented in the 3G that differs from the TDMA implemented in the 2G case. In the worst scenario, corresponding to a continuous transmission and reception at maximum output power (approximately 250 mW or 24 dBm), the current drawn by the module at the VCC pins is in the order of continuous 500-800 mA (see LISA-U2 series Data Sheet [1] for detailed values). Even at lowest output RF power (approximately 0.01 µW or -50 dBm), the current still remains in the order of 200 mA due to module baseband processing and transceiver activity. An example of current consumption profile of the data module in UMTS/HSxPA continuous transmission mode is shown in Figure 13. Current [mA] 850 mA 800 700 600 500 Current consumption depends on TX power and actual antenna load 400 300 200 170 mA 100 1 slot 666 µs 3G frame 10 ms (1 frame = 15 slots) Time [ms] Figure 13: VCC current consumption profile versus time during a UMTS/HSPA connection When a packet data connection is established, the actual current profile depends on the amount of transmitted packets; there might be some periods of inactivity between allocated slots where current consumption drops about 100 mA. Alternatively, at higher data rates the transmitted power is likely to increase due to the higher quality signal required by the network to cope with enhanced data speed. UBX-13001118 - R19 Early Production Information System description Page 29 of 175 LISA-U2 series - System Integration Manual 1.5.3.3 2G and 3G cyclic idle/active mode (power saving enabled) The power saving configuration is by default disabled, but it can be enabled using the appropriate AT command (see the u-blox AT Commands Manual [2], AT+UPSV command). When power saving is enabled, the module automatically enters idle-mode whenever possible. When power saving is enabled, the module is registered or attached to a network and a voice or data call is not enabled, the module automatically enters idle-mode whenever possible, but it must periodically monitor the paging channel of the current base station (paging block reception), in accordance to GSM system requirements. When the module monitors the paging channel, it wakes up to active mode, to enable the reception of paging block. In between, the module switches to idle-mode. This is known as GSM discontinuous reception (DRX). The module processor core is activated during the paging block reception, and automatically switches its reference clock frequency from 32 kHz to the 26 MHz used in active-mode. The time period between two paging block receptions is defined by the network (2G or 3G). This is the paging period parameter, fixed by the base station through broadcast channel sent to all users on the same serving cell. In case of 2G network, the time interval between two paging block receptions can be from 470.76 ms (DRX = 2, i.e. width of 2 GSM multiframes = 2 x 51 GSM frames = 2 x 51 x 4.615 ms) up to 2118.42 ms (DRX = 9, i.e. width of 9 GSM multiframes = 9 x 51 frames = 9 x 51 x 4.615 ms). In case of 3G network, the principle is similar but time interval changes from 640 ms (DRX = 6, i.e. the width of 2 x 3G frames = 64 x 10 ms = 640 ms) up to 5120 ms (DRX = 9, i.e. width of 2 x 3G frames = 512 x 10 ms = 5120 ms). An example of a module current consumption profile is shown in Figure 14: the module is registered with the network (2G or 3G), automatically enters idle-mode and periodically wakes up to active mode to monitor the paging channel for paging block reception. Current [mA] 100 50 Time [s] Current [mA] IDLE MODE ACTIVE MODE 2G case: 0.44-2.09 s 3G case: 0.61-5.09 s 20-30 ms 100 50 Active Mode Enabled IDLE MODE RX Enabled DSP Enabled Idle Mode Enabled 20-30 ms ACTIVE MODE Time [ms] IDLE MODE Figure 14: Description of VCC current consumption profile versus time when the module is registered with 2G or 3G networks: the module is in idle-mode and periodically wakes up to active mode to monitor the paging channel for paging block reception UBX-13001118 - R19 Early Production Information System description Page 30 of 175 LISA-U2 series - System Integration Manual 1.5.3.4 2G and 3G fixed active mode (power saving disabled) Power saving configuration is by default disabled, or it can be disabled using the appropriate AT command (see the u-blox AT Commands Manual [2], AT+UPSV command). When power saving is disabled, the module does not automatically enter idle-mode whenever possible: the module remains in active mode. The module processor core is activated during active-mode, and the 26 MHz reference clock frequency is used. An example of the current consumption profile of the data module when power saving is disabled is shown in Figure 15: the module is registered with the network, active-mode is maintained, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception. Current [mA] 100 50 Time [s] Current [mA] Paging period 2G case: 0.47-2.12 s 3G case: 0.64-5.12 s 100 50 RX Enabled DSP Enabled Time [ms] ACTIVE MODE Figure 15: Description of the VCC current consumption profile versus time when power saving is disabled: the active-mode is always held, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception UBX-13001118 - R19 Early Production Information System description Page 31 of 175 LISA-U2 series - System Integration Manual 1.5.4 RTC Supply (V_BCKP) The V_BCKP pin connects the supply for the Real Time Clock (RTC) and Power-On / Reset internal logic. This supply domain is internally generated by a linear regulator integrated in the Power Management Unit. The output of this linear regulator is always enabled when the main voltage supply provided to the module through VCC is within the valid operating range, with the module switched-off or powered-on. V_BCKP supply output pin provides internal short circuit protection to limit start-up current and protect the device in short circuit situations. No additional external short circuit protection is required. Name Description Remarks V_BCKP Real Time Clock supply V_BCKP output voltage = 1.8 V (typical) Generated by the module to supply Real Time Clock when VCC supply voltage is within valid operating range. Table 12: Real Time Clock supply pin The V_BCKP pin ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point. The RTC provides the time reference (date and time) of the module, also in power-off mode, when the V_BCKP voltage is within its valid range (specified in the Input characteristics of Supply/Power pins table in LISA-U2 series Data Sheet [1]). The RTC timing is normally used to set the wake-up interval during idle-mode periods between network paging, but is able to provide programmable alarm functions by means of the internal 32.768 kHz clock. The RTC can be supplied from an external back-up battery through the V_BCKP, when the main voltage supply is not provided to the module through VCC. This lets the time reference (date and time) run until the V_BCKP voltage is within its valid range, even when the main supply is not provided to the module. The RTC oscillator does not necessarily stop operation (i.e. the RTC counting does not necessarily stop) when V_BCKP voltage value drops below the specified operating range minimum limit (1.00 V): the RTC value read after a system restart could be not reliable, as explained in Table 13. V_BCKP voltage value RTC value reliability Notes 1.00 V < V_BCKP < 1.90 V RTC oscillator does not stop operation RTC value read after a restart of the system is reliable RTC oscillator does not necessarily stop operation RTC value read after a restart of the system is not reliable V_BCKP within operating range RTC oscillator stops operation RTC value read after a restart of the system is reliable V_BCKP below operating range 0.05 V < V_BCKP < 1.00 V 0.00 V < V_BCKP < 0.05 V V_BCKP below operating range Table 13: RTC value reliability as function of V_BCKP voltage value Consider that the module cannot switch on if a valid voltage is not present on VCC even when the RTC is supplied through V_BCKP (meaning that VCC is mandatory to switch-on the module). The RTC has very low power consumption, but is highly temperature dependent. For example at 25°C, with the V_BCKP voltage equal to the typical output value, the power consumption is approximately 2 µA (see the Input characteristics of Supply/Power pins table in the LISA-U2 series Data Sheet [1] for the detailed specification), whereas at 70°C and an equal voltage the power consumption increases to 5-10 µA. UBX-13001118 - R19 Early Production Information System description Page 32 of 175 LISA-U2 series - System Integration Manual The internal regulator for V_BCKP is optimized for low leakage current and very light loads. It is not recommended to use V_BCKP to supply external loads. If V_BCKP is left unconnected and the module main voltage supply is removed from VCC, the RTC is supplied from the bypass capacitor mounted inside the module. However, this capacitor is not able to provide a long buffering time: within few milliseconds the voltage on V_BCKP will go below the valid range (1 V min). This has no impact on cellular connectivity, as all the functionalities of the module do not rely on date and time setting. Leave V_BCKP unconnected if the RTC is not required when the VCC supply is removed. The date and time will not be updated when VCC is disconnected. If VCC is always supplied, then the internal regulator is supplied from the main supply and there is no need for an external component on V_BCKP. If RTC is required to run for a time interval of T [s] at 25°C when VCC supply is removed, place a capacitor with a nominal capacitance of C [µF] at the V_BCKP pin. Choose the capacitor using the following formula: C [µF] = (Current_Consumption [µA] x T [s]) / Voltage_Drop [V] = 2.50 x T [s] for LISA-U2 series For example, a 100 µF capacitor (such as the Murata GRM43SR60J107M) can be placed at V_BCKP to provide a long buffering time. This capacitor will hold V_BCKP voltage within its valid range for around 50 s at 25°C, after the VCC supply is removed. If a very long buffering time is required, a 70 mF super-capacitor (e.g. Seiko Instruments XH414H-IV01E) can be placed at V_BCKP, with a 4.7 k series resistor to hold the V_BCKP voltage within its valid range for approximately 10 hours at 25°C, after the VCC supply is removed. The purpose of the series resistor is to limit the capacitor charging current due to the large capacitor specifications, and also to let a fast rise time of the voltage value at the V_BCKP pin after VCC supply has been provided. These capacitors will allow the time reference to run during battery disconnection. (a) LISA-U2 series (b) V_BCKP C1 LISA-U2 series R2 (c) LISA-U2 series V_BCKP V_BCKP D3 B3 C2 (superCap) Figure 16: Real time clock supply (V_BCKP) application circuits: (a) using a 100 µF capacitor to let the RTC run for ~50 s after VCC removal; (b) using a 70 mF capacitor to let RTC run for ~10 hours after VCC removal; (c) using a non-rechargeable battery Reference Description Part Number - Manufacturer C1 100 µF Tantalum Capacitor GRM43SR60J107M - Murata R2 C2 4.7 kΩ Resistor 0402 5% 0.1 W 70 mF Capacitor RC0402JR-074K7L - Yageo Phycomp XH414H-IV01E - Seiko Instruments Table 14: Example of components for V_BCKP buffering If longer buffering time is required to allow the time reference to run during a disconnection of the VCC supply, then an external battery can be connected to V_BCKP pin. The battery should be able to provide a proper nominal voltage and must never exceed the maximum operating voltage for V_BCKP (specified in the Input characteristics of Supply/Power pins table in LISA-U2 series Data Sheet [1]). The connection of the battery to V_BCKP should be done with a suitable series resistor for a rechargeable battery, or with an appropriate series diode for a non-rechargeable battery. The purpose of the series resistor is to limit the battery charging current due to the battery specifications, and also to allow a fast rise time of the voltage value at the V_BCKP pin after UBX-13001118 - R19 Early Production Information System description Page 33 of 175 LISA-U2 series - System Integration Manual the VCC supply has been provided. The purpose of the series diode is to avoid a current flow from the module V_BCKP pin to the non-rechargeable battery. Combining a LISA-U2 series cellular module with a u-blox GNSS receiver, the VCC supply of the GNSS receiver is controlled by the cellular module by means of the “GNSS supply enable” function provided by the GPIO2 of the cellular module. In this case the V_BCKP supply output of the LISA-U2 series cellular module can be connected to the V_BCKP backup supply input pin of the GNSS receiver to provide the supply for the GNSS real time clock and backup RAM when the VCC supply of the cellular module is within its operating range and the VCC supply of the GNSS receiver is disabled. This enables the u-blox GNSS receiver to recover from a power breakdown with either a hotstart or a warmstart (depending on the duration of the GNSS VCC outage) and to maintain the configuration settings saved in the backup RAM. See the section 1.10 for more details regarding the application circuit with a u-blox GNSS receiver. UBX-13001118 - R19 Early Production Information System description Page 34 of 175 LISA-U2 series - System Integration Manual 1.5.5 Interface supply (V_INT) The same voltage domain used internally to supply the digital interfaces is also available on the V_INT pin. The internal regulator that generates the V_INT supply is a switching step down converter that is directly supplied from VCC. The voltage regulator output is set to 1.8 V (typical) when the module is switched on and is disabled when the module is switched off or when the RESET_N pin is forced the low level. The switching regulator operates in Pulse Width Modulation (PWM) for high output current mode but automatically switches to Pulse Frequency Modulation (PFM) at low output loads for greater efficiency, e.g. when the module is in idle-mode between paging periods. V_INT supply output pin provides internal short circuit protection to limit start-up current and protect the device in short circuit situations. No additional external short circuit protection is required. Name Description Remarks V_INT Digital Interfaces supply output V_INT = 1.8V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. V_INT is the internal supply for digital interfaces. The user may draw limited current from this supply rail. Table 15: Interface supply pin The V_INT pin ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point. Since it supplies internal digital circuits (see Figure 3), V_INT is not suited to directly supply any sensitive analog circuit: the voltage ripple can range from 15 mVpp during active mode (PWM), to 70 mVpp in idle-mode (PFM). V_INT can be used to supply external digital circuits operating at the same voltage level as the digital interface pins, i.e. 1.8 V (typical). It is not recommended to supply analog circuitry without adequate filtering for digital noise. Do not apply loads which might exceed the limit for maximum available current from V_INT supply, as this can cause malfunctions in internal circuitry supplies to the same domain. The detailed electrical characteristics are described in LISA-U2 series Data Sheet [1]. V_INT can only be used as an output; do not connect any external regulator on V_INT. If not used, this pin should be left unconnected. The V_INT digital interfaces supply output is mainly used to: Pull-up DDC (I C) interface signals (see section 1.10.2 for more details) Pull-up SIM detection signal (see section 1.8 for more details) Supply voltage translators to connect digital interfaces of the module to a 3.0 V device (see sections 1.9.2.4, 1.9.4.4 for more details) Supply a 1.8 V u-blox 6 or subsequent GNSS receiver (see section 1.10.2 for more details) Indicate when the module is switched on and the RESET_N external hardware reset input is not forced low (see sections 1.6.1.5, 1.6.2 and 1.6.3 for more details) UBX-13001118 - R19 Early Production Information System description Page 35 of 175 LISA-U2 series - System Integration Manual 1.6 System functions 1.6.1 Module power-on When the LISA-U2 series modules are in the not-powered mode (i.e. switched off with the VCC module supply not applied), they can be switched on by: Rising edge on the VCC pin to a valid voltage as module supply (i.e. applying module supply) Alternately, the RESET_N pin can be held to the low level during the VCC rising edge, so that the module switches on releasing the RESET_N pin when the VCC module supply voltage stabilizes at its proper nominal value within the normal operating range The status of the PWR_ON input pin of LISA-U2 series modules while applying the VCC module supply is not relevant: during this phase the PWR_ON pin can be set high or low by the external circuit. When the LISA-U2 series modules are in the power-off mode (i.e. switched off by means of the AT+CPWROFF command, with valid VCC module supply applied), they can be switched on by: Low pulse on the PWR_ON pin (i.e. forcing to the low level the pin normally high by external pull-up) Rising edge on the RESET_N pin (i.e. releasing from low level the pin, normally high by internal pull-up) RTC alarm (i.e. pre-programmed scheduled time by AT+CALA command) Name Description Remarks PWR_ON Power-on input PWR_ON pin has high input impedance. Do not keep floating in noisy environment: external pull-up required. Table 16: Power-on pin The PWR_ON pin ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point. 1.6.1.1 Rising edge on VCC Applying a proper supply to VCC pins, the module supply supervision circuit controls the subsequent activation of the power up state machines: the module is switched on when the voltage rises up to the VCC normal operating range minimum limit starting from a voltage value lower than 2.25 V (see LISA-U2 series Data Sheet [1] for the VCC normal operating range minimum limit). The voltage at VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to properly switch on the module. If the external supply circuit is not able to provide this VCC voltage slope, keep the RESET_N input low during the VCC rising edge, so that the module switches on, releasing the RESET_N pin when the VCC voltage stabilizes at its nominal value within the normal operating range. The status of the PWR_ON input pin during the VCC apply phase is not relevant: LISA-U2 modules switch on when a proper rising edge on the VCC pin is applied, during this phase the PWR_ON pin can be set high or low by the external circuit. UBX-13001118 - R19 Early Production Information System description Page 36 of 175 LISA-U2 series - System Integration Manual 1.6.1.2 Low pulse on PWR_ON When the module is in power-off mode, i.e. it has been properly switched off as described in the section 1.6.2 (e.g. by the AT+CPWROFF command) and a voltage within the operating range is maintained at the VCC pins, the module can be switched on by means of the PWR_ON input pin: a falling edge must be provided on the PWR_ON pin, which must be then held low for an appropriate time period as specified in LISA-U2 series Data Sheet [1]. The electrical characteristics of the PWR_ON input pin are different from the other digital I/O interfaces; the detailed electrical characteristics are described in LISA-U2 series Data Sheet [1]. The PWR_ON pin has high input impedance and is weakly pulled to the high level on the module. Avoid keeping it floating in a noisy environment. To hold the high logic level stable, the PWR_ON pin must be connected to a pull-up resistor (e.g. 100 kΩ) biased by the V_BCKP supply pin of the module. Following are some typical examples of application circuits to turn the module on using the PWR_ON input pin. Connecting the PWR_ON input to an external device (e.g. application processor), use an open drain output on the external device with an external pull-up resistor (e.g. 100 kΩ) biased by V_BCKP supply pin of the module. A push-pull output of an application processor can also be used: in this case the pull-up can be used to pull the PWR_ON level high when the application processor is switched off. If the high-level voltage of the push-pull output pin of the application processor is greater than the maximum input voltage operating range of the V_BCKP pin (see the V_BCKP Input characteristics of Supply/Power pins table in LISA-U2 series Data Sheet [1]), the V_BCKP supply cannot be used to bias the pull-up resistor: the supply rail of the application processor or the VCC supply could be used, but this will increase the V_BCKP (RTC supply) current consumption when the module is in not-powered mode (VCC supply not present). Using a push-pull output of the external device, take care to fix the proper level in all the possible scenarios to avoid an inappropriate switch-on of the module. Application processor LISA-U2 series Open Drain Output V_BCKP Rext 19 PWR_ON Figure 17: PWR_ON application circuits using an open drain output of an application processor Reference Description Remarks Rext 100 kΩ Resistor 0402 5% 0.1 W External pull-up resistor Table 17: Example of pull-up resistor for the PWR_ON application circuit UBX-13001118 - R19 Early Production Information System description Page 37 of 175 LISA-U2 series - System Integration Manual 1.6.1.3 Rising edge on RESET_N When the module is in power-off mode (i.e. switched off with VCC maintained), the module can be switched on by means of the RESET_N input pin alternatively to the PWR_ON input pin: the RESET_N signal must be forced low for at least 50 ms and then released to generate a rising edge that starts the module power-on sequence. RESET_N input pin can also be used to perform an “external” or “hardware” reset of the module, as described in the section 1.6.3. Electrical characteristics of the LISA-U2 series RESET_N input are slightly different from the other digital I/O interfaces: the pin provides different input voltage thresholds. Detailed electrical characteristics are described in LISA-U2 series Data Sheet [1]. RESET_N is pulled high to V_BCKP by an integrated pull-up resistor also when the module is in power-off mode. Therefore an external pull-up is not required on the application board. The simplest way to switch on the module by means of the RESET_N input pin is to use a push button that shorts the RESET_N pin to ground: the module will be switched on at the release of the push button, since the RESET_N will be forced to the high level by the integrated pull-up resistor, generating a rising edge. If RESET_N is connected to an external device (e.g. an application processor on an application board) an open drain output can be directly connected without any external pull-up. A push-pull output can be used too: in this case make sure that the high level voltage of the push-pull circuit is below the maximum voltage operating range of the RESET_N pin (specified in the RESET_N pin characteristics table in LISA-U2 series Data Sheet [1]). To avoid unwanted power-on or reset of the module make sure to fix the proper level at the RESET_N input pin in all possible scenarios. Some typical examples of application circuits using the RESET_N input pin are described in the section 1.6.3. 1.6.1.4 Real Time Clock (RTC) alarm When the module is in power-off mode (i.e. switched off with VCC maintained), it can be switched on by means of an RTC alarm previously programmed (see the u-blox AT Commands Manual [2], AT+CALA command) alternatively to the PWR_ON and RESET_N pins: the RTC system will initiate the power-on sequence. 1.6.1.5 Additional considerations The module is switched on when the VCC voltage rises up to the normal operating range (i.e. applying supply properly, as described in section 1.6.1.1): the module is commonly switched on in this way for the first time. Then, the module must be properly switched off as described in section 1.6.2, e.g. by AT+CPWROFF command. When the module is in power-off mode, i.e. it has been properly switched off as described in the section 1.6.2 (e.g. by the AT+CPWROFF command) and a voltage within the operating range is maintained at the VCC pins, the module can be switched on by a proper start-up event (i.e. by PWR_ON as described in Figure 18 and section 1.6.1.2, or by RESET_N as described in section 1.6.1.3, or by RTC alarm as described in section 1.6.1.4). UBX-13001118 - R19 Early Production Information System description Page 38 of 175 LISA-U2 series - System Integration Manual Figure 18 shows the modules power-on sequence from the power-off mode, describing the following phases: The external supply is still applied to the VCC inputs as it is assumed that the module has been previously switched off by means of the AT+CPWROFF command: the V_BCKP output is internally enabled as proper VCC is present, the RESET_N of LISA-U2 series is set to high logic level due to internal pull-up to V_BCKP, the PWR_ON is set to high logic level due to external pull-up connected to V_BCKP or VCC. The PWR_ON input pin is set low for a valid time period, representing the start-up event. All the generic digital pins of the modules are tri-stated until the switch-on of their supply source (V_INT): any external signal connected to the generic digital pins must be tri-stated or set low at least until the activation of the V_INT supply output to avoid latch-up of circuits and allow a proper boot of the module. The V_INT generic digital interfaces supply output is enabled by the integrated power management unit. The internal reset signal is held low by the integrated power management unit: the baseband processor core and all the digital pins of the modules are held in reset state, which is reported for each pin of the module in the pin description table of LISA-U2 series Data Sheet [1]. When the internal reset signal is released by the integrated power management unit, the processor core starts to configure the digital pins of the modules to each default operational state. The duration of these pins’ configuration phase differs within generic digital interfaces (3 s typical) and USB interface due to specific host / device enumeration timings (5 s typical, see the section 1.9.3.1). The host application processor should not send any AT command over the AT interfaces (USB, UART) of the modules until the end of these interfaces’ configuration phase to allow a proper boot of the module. After the interfaces’ configuration phase, the application can start sending AT commands, and the following starting procedure is suggested to check the effective completion of the module internal boot sequence: send AT and wait for the response with a 30 s timeout, iterate it 4 times without resetting or removing the VCC supply of the module, and then run the application. Start-up PWR_ON event can be set high Start of interface configuration Generic digital interfaces are configured VCC V_BCKP PWR_ON V_INT Internal Reset OFF System State BB Pads State Tristate / Floating 0 ms ON Internal Reset Internal Reset → Operational ~35 ms Operational ~3 s Figure 18: LISA-U2 series power-on sequence description The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin to sense the start of the power-on sequence. Any external signal connected to the UART interface, SPI/IPC interface, I S interfaces and GPIOs must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and let a proper boot of the module. If the external signals connected to the cellular module cannot be tri-stated, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode, when external reset is forced low and during power on sequence. UBX-13001118 - R19 Early Production Information System description Page 39 of 175 LISA-U2 series - System Integration Manual 1.6.2 Module power-off The power-off sequence of LISA-U2 series modules can be correctly started, so that the current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed, in one of these ways: AT+CPWROFF command (more details in u-blox AT Commands Manual [2]) Low pulse on the PWR_ON pin for at least 1 s An over-temperature or an under-temperature shutdown occurs when the temperature measured within the cellular module reaches the dangerous area, if the optional Smart Temperature Supervisor feature is enabled and configured by the dedicated AT command. For more details see the section 3.15 and to the u-blox AT Commands Manual [2], +USTS AT command. An abrupt under-voltage shutdown occurs on LISA-U2 modules when the VCC supply is removed, but in this case the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach cannot be performed. It is highly recommended to avoid an abrupt removal of the VCC supply: the power off sequence of the module must be properly started as described above (e.g. by means of the AT+CPWROFF command), and a proper VCC supply must be maintained at least until the end of the power off sequence, which occurs when the generic digital interfaces supply output (V_INT) is switched off by the module. An abrupt hardware shutdown occurs on LISA-U2 series modules when a low level is applied to the RESET_N pin. In this case, the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. It is highly recommended to avoid an abrupt hardware shutdown of the module by forcing a low level on the RESET_N input pin during module normal operation: the RESET_N line should be set low only if reset or shutdown via AT commands fails or if the module does not reply to a specific AT command after a time period longer than the one defined in the u-blox AT Commands Manual [2]. UBX-13001118 - R19 Early Production Information System description Page 40 of 175 LISA-U2 series - System Integration Manual Figure 19 describes the module’s power-off sequence, properly started by sending the AT+CPWROFF command, allowing storage of current parameter settings in the module’s non-volatile memory and a proper network detach: When the +CPWROFF AT command is sent, the module starts the switch-off routine. The module replies OK on the AT interface: the switch-off routine is in progress. At the end of the switch-off routine, all the digital pins are tri-stated and all the internal voltage regulators are turned off, including the generic digital interfaces supply (V_INT), except the RTC supply (V_BCKP). Then, the module remains in power-off mode as long as a switch on event does not occur (e.g. applying a proper low level to the PWR_ON input, or applying a proper low level to the RESET_N input), and enters not-powered mode if the supply is removed from the VCC pins. AT+CPWROFF sent to the module OK replied by the module VCC can be removed VCC V_BCKP PWR_ON RESET_N V_INT Internal Reset ON System State BB Pins State Operational 0s OFF Operational → Tristate ~50 ms Tristate / Floating ~400 ms Figure 19: LISA-U2 series Power-off sequence description The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin to sense the end of the LISA-U2 series power-off sequence. The duration of each phase in the LISA-U2 series modules’ switch-off routines can largely vary from the values reported in Figure 19 (e.g. from tens of milliseconds up to tens of seconds), depending on the application / network settings and the concurrent module activities. If the AT command +CPWROFF is issued to switch off the module over a multiplexer channel, the completion of the module power-off sequence could require additionally up to 2.5 s, after the module OK reply. Therefore, if the Application Processor (AP) controls the VCC supply of the module, the AP should disable the multiplexer protocol and then issue the AT+CPWROFF command over the used AT interface, or otherwise the AP should issue the AT+CPWROFF command over a multiplexer channel and wait additionally 2.5 s after OK reception before removing the module VCC supply. Tristated pins are always subject to floating caused by noise: to prevent unwanted effects, fix them with proper pull-up or pull down resistors to stable voltage rails to fix their level when the module is in Power down state. Any external signal connected to the UART interface, SPI/IPC interface, I S interfaces and GPIOs must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the cellular module cannot be tristated, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode, when external reset is forced low and during power-on sequence. UBX-13001118 - R19 Early Production Information System description Page 41 of 175 LISA-U2 series - System Integration Manual 1.6.3 Module reset LISA-U2 series modules can be properly reset (rebooted) by: AT+CFUN command (see the u-blox AT Commands Manual [2] for more details). This command causes an “internal” or “software” reset of the module, causing an asynchronous reset of the module baseband processor, excluding the integrated Power Management Unit and the RTC internal block. The V_INT interfaces supply is enabled and each digital pin is set in its internal reset state (reported in the pin description table in LISA-U2 series Data Sheet [1]), the V_BCKP supply and the RTC block are enabled. Forcing an “internal” or “software” reset, the current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed: this is the proper way to reset the modules. An abrupt hardware reset occurs on LISA-U2 series modules when a low level is applied on the RESET_N input pin for a specific time period. In this case, the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. It is highly recommended to avoid an abrupt “external” or “hardware” reset of the module by forcing a low level on the RESET_N input pin during the module normal operation: the RESET_N line should be set low only if reset or shutdown via AT commands fails or if the module does not provide a reply to a specific AT command after a time period longer than the one defined in the u-blox AT Commands Manual [2]. When a low level is applied to the RESET_N input, it causes an “external” or “hardware” reset of the module, with an asynchronous abrupt reset of the entire module, including the integrated Power Management Unit, except for the RTC internal block. The V_INT interfaces supply is switched off and all the digital pins of the modules are tri-stated, but the V_BCKP supply and the RTC block are enabled. Forcing an “external” or “hardware” reset, the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. When RESET_N is released from the low level, the module automatically starts its power-on sequence from the reset state. The same procedure is followed for the module reset via AT command after having performed the network detach and the parameter saving in non-volatile memory. Name Description Remarks RESET_N External reset input Internal 10 k pull-up to V_BCKP Table 18: Reset pin The RESET_N pin ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the line is externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin, close to accessible point. For more details about RESET_N circuit precautions for ESD immunity, see section 2.5.3. The electrical characteristics of RESET_N are different from the other digital I/O interfaces. The detailed electrical characteristics are described in LISA-U2 series Data Sheet [1]. RESET_N is pulled high by an integrated 10 k pull-up resistor to V_BCKP. Therefore an external pull-up is not required on the application board. Following are some typical examples of application circuits using the RESET_N input pin. The simplest way to reset the module is to use a push button that shorts the RESET_N pin to ground. UBX-13001118 - R19 Early Production Information System description Page 42 of 175 LISA-U2 series - System Integration Manual If RESET_N is connected to an external device (e.g. an application processor on an application board) an open drain output can be directly connected without any external pull-up. A push-pull output can be used too: in this case make sure that the high level voltage of the push-pull circuit is below the maximum voltage operating range of the RESET_N pin (specified in the RESET_N pin characteristics table in LISA-U2 series Data Sheet [1]). To avoid unwanted reset of the module make sure to fix the proper level at the RESET_N input pin in all possible scenarios. As ESD immunity test precaution, a 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01), a proper series chip ferrite bead noise/EMI suppression filter (e.g. Murata BLM15HD182SN1) and a 220 nF bypass capacitor (e.g. Murata GRM155R60J224KE01) must be added as close as possible to the RESET_N pin of LISA-U2 series modules to avoid a module reset caused by an electrostatic discharge applied to the application board (for more details, see section 2.5.3). LISA-U2 series Reset push button V_BCKP Rint EMI1 22 RESET_N ESD C1 C2 Application processor LISA-U2 series Open Drain Output V_BCKP Rint EMI2 22 RESET_N C3 C4 Figure 20: RESET_N application circuits using a push button and an open drain output of an application processor Reference Description Remarks ESD Varistor for ESD protection. CT0402S14AHSG - EPCOS C1, C3 C2, C4 47 pF Capacitor Ceramic C0G 0402 5% 50 V 220 nF Capacitor Ceramic X5R 0402 10% 6.3 V GRM1555C1H470JA01 - Murata GRM155R60J224KE01 - Murata EMI1, EMI2 Chip Ferrite Bead Noise/EMI Suppression Filter 1800 Ω at 100 MHz, 2700 Ω at 1 GHz 10 kΩ Resistor 0402 5% 0.1 W BLM15HD182SN1 - Murata Rint Internal pull-up resistor Table 19: Example of ESD protection components for the RESET_N application circuit Any external signal connected to the UART interface, SPI/IPC interface, I S interfaces and GPIOs must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the cellular module cannot be tristated, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode, when external reset is forced low and during power-on sequence. UBX-13001118 - R19 Early Production Information System description Page 43 of 175 LISA-U2 series - System Integration Manual 1.7 RF connection The ANT pin, provided by all LISA-U2 modules, represents the main RF input/output used to transmit and receive the 2G and 3G RF signal: the main antenna must be connected to this pad. The ANT pin has a nominal characteristic impedance of 50 and must be connected to the antenna through a 50 transmission line to allow transmission and reception of radio frequency (RF) signals in the 2G and 3G operating bands. The ANT_DIV pin, provided by LISA-U230 modules, represents the RF input for the integrated diversity receiver implemented for both 2G and 3G cases: the antenna for the Rx diversity must be connected to this pad. The ANT_DIV pin has a nominal characteristic impedance of 50 and must be connected to the antenna for the Rx diversity through a 50 transmission line to allow reception of radio frequency (RF) signals, improving the cellular link quality and reliability on all 2G and 3G operating bands except the 2G DCS 1800. Name Module Description Remarks ANT All RF input/output for main Tx/Rx antenna Zo = 50 nominal characteristic impedance. ANT_DIV LISA-U230 RF input for Rx diversity antenna Zo = 50 nominal characteristic impedance. Table 20: Antenna pins ESD immunity rating of ANT port is 1000 V (according to IEC 61000-4-2). Higher protection level could be required if the line is externally accessible on the application board (for further details see section 2.5.3). Choose an antenna with optimal radiating characteristics for the best electrical performance and overall module functionality. An internal antenna, integrated on the application board, or an external antenna, connected to the application board through a proper 50 connector, can be used. See section 2.4 and section 2.2.1.1 for further details regarding antenna guidelines. The recommendations of the antenna producer for correct installation and deployment (PCB layout and matching circuitry) must be followed. If an external antenna is used, the PCB-to-RF-cable transition must be implemented using either a suitable 50 connector, or an RF-signal solder pad (including GND) that is optimized for 50 characteristic impedance. If antenna supervisor functionality is required, the main antenna connected to the ANT pin should have a built in DC diagnostic resistor to ground to get proper detection functionality (See section 2.4.4). Connect the Rx diversity antenna to the ANT_DIV pin of LISA-U230 modules unless the 2G and 3G Rx diversity feature is disabled by AT command (see the u-blox AT Commands Manual [2], +URXDIV command). The same pin (74) is marked RSVD (reserved) on the other modules that do not implement Rx diversity: in this case the RSVD pin can be left unconnected. UBX-13001118 - R19 Early Production Information System description Page 44 of 175 LISA-U2 series - System Integration Manual 1.8 (U)SIM interface High-speed SIM/ME interface is implemented as well as automatic detection of the required SIM supporting voltage. Both 1.8 V and 3 V SIM types are supported: activation and deactivation with automatic voltage switch from 1.8 V to 3 V is implemented, according to ISO-IEC 7816-3 specifications. The SIM driver supports the PPS (Protocol and Parameter Selection) procedure for baud-rate selection, according to the values determined by the SIM Card. The VSIM supply output pin provides internal short circuit protection to limit start-up current and protect the device in short circuit situations. No additional external short circuit protection is required. Name Description Remarks VSIM SIM supply SIM_CLK SIM clock 1.80 V typical or 2.90 V typical Automatically generated by the module 3.25 MHz clock frequency SIM_IO SIM data Open drain, internal 4.7 k pull-up resistor to VSIM SIM_RST SIM reset Table 21: SIM Interface pins A low capacitance (i.e. less than 10 pF) ESD protection (e.g. Infineon ESD8V0L2B-03L or AVX USB0002RP) must be placed near the SIM card holder on each line (VSIM, SIM_IO, SIM_CLK, SIM_RST). The SIM interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F): higher protection level is required if the lines are connected to an SIM card connector, since they are externally accessible on the application board. For more details about the general precautions for ESD immunity about SIM interface pins, see section 2.5.3. The following SIM services are supported: Abbreviated Dialing Numbers (ADN) Fixed Dialing Numbers (FDN) Last Dialed Numbers (LDN) Service Dialing Numbers (SDN) SIM Application Toolkit and USIM Application Toolkit (USAT) are supported. The GPIO5 pin is configured as an external interrupt to detect the SIM card mechanical / physical presence. The pin is configured as input with an internal active pull-down enabled, and it can sense SIM card presence only if properly connected to the mechanical switch of a SIM card holder as described in section 1.8.1.4 and 1.8.1.5: Low logic level at GPIO5 input pin is recognized as SIM card not present High logic level at GPIO5 input pin is recognized as SIM card present The SIM card detection function provided by GPIO5 pin is an optional feature that can be implemented / used or not according to the application requirements. An Unsolicited Result Code (URC) can be generated each time that there is a change of status (for more details see the “simind” value of theparameter of +CIND and +CMER commands in the u-blox AT Commands Manual [2]). All the LISA-U2 series modules provide the additional function “SIM card hot insertion/removal” on the GPIO5 pin, which can be enabled using the AT+UDCONF=50 command. For more details on SIM detection function see section 1.12 as well as the u-blox AT Commands Manual [2], +UGPIOC, +UDCONF=50 commands. UBX-13001118 - R19 Early Production Information System description Page 45 of 175 LISA-U2 series - System Integration Manual 1.8.1 (U)SIM application circuits 1.8.1.1 SIM cards, SIM connectors and SIM chips selection The ISO/IEC 7816, the ETSI TS 102 221 and the ETSI TS 102 671 specifications define the physical, electrical and functional characteristics of Universal Integrated Circuit Cards (UICC) which contains the Subscriber Identification Module (SIM) integrated circuit that securely stores all the information needed to identify and authenticate subscribers over the GSM network. Removable UICC / SIM card contacts mapping is defined by ISO/IEC 7816 and ETSI TS 102 221as follows: Contact C1 = VCC (Supply) It must be connected to VSIM Contact C2 = RST (Reset) It must be connected to SIM_RST Contact C3 = CLK (Clock) It must be connected to SIM_CLK Contact C4 = AUX1 (Auxiliary contact) It must be left not connected Contact C5 = GND (Ground) It must be connected to GND Contact C6 = VPP (Programming supply) It must be connected to VSIM Contact C7 = I/O (Data input/output) It must be connected to SIM_IO Contact C8 = AUX2 (Auxiliary contact) It must be left not connected A removable SIM card can have 6 contacts (C1 = VCC, C2 = RST, C3 = CLK, C5 = GND, C6 = VPP, C7 = I/O) or 8 contacts, providing also the auxiliary contacts C4 = AUX1 and C8 = AUX2 for USB interfaces and other uses. Only 6 contacts are required and must be connected to the module SIM card interface as described above , since LISA-U2 modules do not support the additional auxiliary features (contacts C4 = AUX1 and C8 = AUX2). Removable SIM cards are suitable for applications where the SIM changing is required during the product lifetime. A SIM card holder can have 6 or 8 positions if a mechanical card presence detector is not provided, or it can have 6+2 or 8+2 positions if two additional pins corresponding to the normally-open mechanical switch integrated in the SIM connector for the mechanical card presence detection are provided: select a SIM connector providing 6+2 or 8+2 positions if the optional SIM detection feature is required by the custom application, otherwise a connector without integrated mechanical presence switch can be selected. Solderable UICC / SIM chip contacts mapping (M2M UICC Form Factor) is defined by ETSI TS 102 671 as follows: Package Pin 8 = UICC Contact C1 = VCC (Supply) It must be connected to VSIM Package Pin 7 = UICC Contact C2 = RST (Reset) It must be connected to SIM_RST Package Pin 6 = UICC Contact C3 = CLK (Clock) It must be connected to SIM_CLK Package Pin 5 = UICC Contact C4 = AUX1 (Auxiliary contact) It must be left not connected Package Pin 1 = UICC Contact C5 = GND (Ground) It must be connected to GND Package Pin 2 = UICC Contact C6 = VPP (Programming supply) It must be connected to VSIM Package Pin 3 = UICC Contact C7 = I/O (Data input/output) It must be connected to SIM_IO Package Pin 4 = UICC Contact C8 = AUX2 (Auxiliary contact) It must be left not connected A solderable SIM chip has 8 contacts and can provide also the auxiliary contacts C4 = AUX1 and C8 = AUX2 for USB interfaces and other uses, but only 6 contacts are required and must be connected to the module SIM card interface as described above, since LISA-U2 modules do not support the additional auxiliary features (contacts C4 = AUX1 and C8 = AUX2). Solderable SIM chips are suitable for M2M applications where it is not required to change the SIM once installed. UBX-13001118 - R19 Early Production Information System description Page 46 of 175 LISA-U2 series - System Integration Manual 1.8.1.2 Single SIM card without detection A removable SIM card placed in a SIM card holder must be connected to the SIM card interface of LISA-U2 modules as described in Figure 21, where the optional SIM detection feature is not implemented (see the circuit described in Figure 23 if the SIM detection feature is required). Follow these guidelines connecting the module to a SIM connector without the SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) and C6 (VPP) to the VSIM pin of the module Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module Connect the UICC / SIM contact C5 (GND) to ground Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the corresponding pad of the SIM connector, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H330J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each specific pad of the SIM connector, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each specific pad of the SIM connector: ESD sensitivity rating of the SIM interface pins is 1 kV (Human Body Model according to JESD22-A114), so that, according to the EMC/ESD requirements of the custom application, higher protection level can be required if the lines are externally accessible on the application device Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) LISA-U2 series V_INT SIM CARD HOLDER GPIO5 51 VPP (C6) VSIM 50 VCC (C1) SIM_IO 48 IO (C7) SIM_CLK 47 CLK (C3) SIM_RST 49 RST (C2) C1 C2 C3 C4 C5 GND (C5) D1 D2 D3 D4 C C C C 5 6 7 8 C C C C 1 2 3 4 SIM Card Bottom View (contacts side) J1 Figure 21: Application circuit for the connection to a single removable SIM card, with SIM detection not implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 33 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H330JZ01 - Murata C5 D1, D2, D3, D4 100 nF Capacitor Ceramic X7R 0402 10% 16 V Very Low Capacitance ESD Protection GRM155R71C104KA01 - Murata PESD0402-140 - Tyco Electronics J1 SIM Card Holder 6 positions, without card presence switch Various Manufacturers, C707 10M006 136 2 - Amphenol Table 22: Example of components for the connection to a single removable SIM card, with SIM detection not implemented UBX-13001118 - R19 Early Production Information System description Page 47 of 175 LISA-U2 series - System Integration Manual 1.8.1.3 Single SIM chip A solderable SIM chip (M2M UICC Form Factor) must be connected the SIM card interface of LISA-U2 modules as described in Figure 22, where the optional SIM detection feature is not implemented (see the circuit described in Figure 23 if the SIM detection feature is required). Follow these guidelines connecting the module to a solderable SIM chip without the SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) and C6 (VPP) to the VSIM pin of the module Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module Connect the UICC / SIM contact C5 (GND) to ground Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM) close to the specific pad of the SIM chip, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H330J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) LISA-U2 series V_INT SIM CHIP GPIO5 51 VSIM 50 SIM_IO 48 SIM_CLK 47 SIM_RST 49 C1 C2 C3 C4 C5 VPP (C6) VCC (C1) IO (C7) CLK (C3) RST (C2) GND (C5) 8 C1 C5 1 7 C2 C6 2 6 C3 C7 3 5 C4 C8 4 SIM Chip Bottom View (contacts side) U1 Figure 22: Application circuit for the connection to a single solderable SIM chip, with SIM detection not implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 33 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H330JZ01 - Murata C5 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V SIM chip (M2M UICC Form Factor) GRM155R71C104KA01 - Murata Various Manufacturers Table 23: Example of components for the connection to a single solderable SIM chip, with SIM detection not implemented 1.8.1.4 Single SIM card with detection A removable SIM card placed in a SIM card holder must be connected to the SIM card interface of LISA-U2 modules as described in Figure 23, where the optional SIM card detection feature is implemented so that the module detects by means of the GPIO5 if a SIM card is present in the connector. The SW1 and SW2 pins of the SIM card holder are connected to a normally-open mechanical switch integrated in the SIM connector. The following cases are available: SIM card not present: the GPIO5 signal is forced low by the pull-down resistor connected to ground (i.e. the switch integrated in the SIM connector is open) SIM card present: the GPIO5 signal is forced high by the pull-up resistor connected to V_INT (i.e. the switch integrated in the SIM connector is closed) UBX-13001118 - R19 Early Production Information System description Page 48 of 175 LISA-U2 series - System Integration Manual Follow these guidelines connecting the module to a SIM connector implementing the SIM presence detection: Connect the UICC / SIM contacts C1 (VCC) and C6 (VPP) to the VSIM pin of the module Connect the UICC / SIM contact C7 (I/O) to the SIM_IO pin of the module Connect the UICC / SIM contact C3 (CLK) to the SIM_CLK pin of the module Connect the UICC / SIM contact C2 (RST) to the SIM_RST pin of the module Connect the UICC / SIM contact C5 (GND) to ground Connect one pin of the mechanical switch integrated in the SIM connector (e.g. the SW2 pin as described in Figure 23) to the GPIO5 input pin of the module Connect the other pin of the mechanical switch integrated in the SIM connector (e.g. the SW1 pin as described in Figure 23) to the V_INT 1.8 V supply output of the module by means of a strong (e.g. 1 k) pull-up resistor, as the R1 resistor in Figure 23 Provide a weak (e.g. 470 k) pull-down resistor at the SIM detection line, as the R2 resistor in Figure 23 Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the specific pad of the SIM connector, to prevent digital noise Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H330J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each specific pad of the SIM connector, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holder Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each specific pad of the SIM connector: ESD sensitivity rating of the SIM interface pins is 1 kV (Human Body Model according to JESD22-A114), so that, according to the EMC/ESD requirements of the custom application, higher protection level can be required if the lines are externally accessible on the application device Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines) SIM CARD HOLDER LISA-U2 series V_INT SW1 R1 GPIO5 51 SW2 R2 VPP (C6) VSIM 50 VCC (C1) SIM_IO 48 IO (C7) SIM_CLK 47 CLK (C3) SIM_RST 49 RST (C2) C1 C2 C3 C4 C5 GND (C5) D1 D2 D3 D4 D5 D6 C C C C 5 6 7 8 C C C C 1 2 3 4 SIM Card Bottom View (contacts side) J1 Figure 23: Application circuit for the connection to a single removable SIM card, with SIM detection implemented Reference Description Part Number - Manufacturer C1, C2, C3, C4 33 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H330JZ01 - Murata C5 D1, D2, D3, D4, D5, D6 R1 100 nF Capacitor Ceramic X7R 0402 10% 16 V Very Low Capacitance ESD Protection GRM155R71C104KA01 - Murata PESD0402-140 - Tyco Electronics 1 k Resistor 0402 5% 0.1 W RC0402JR-071KL - Yageo Phycomp R2 470 k Resistor 0402 5% 0.1 W RC0402JR-07470KL- Yageo Phycomp J1 SIM Card Holder 6 + 2 positions, with card presence switch Various Manufacturers, CCM03-3013LFT R102 - C&K Components Table 24: Example of components for the connection to a single removable SIM card, with SIM detection implemented UBX-13001118 - R19 Early Production Information System description Page 49 of 175 LISA-U2 series - System Integration Manual 1.8.1.5 Dual SIM card connection Two SIM cards / chips can be connected to the module’s SIM interface, as described in the circuit of Figure 24. LISA-U2 modules do not support the usage of two SIMs at the same time, but two SIMs can be populated on the application board providing a proper switch to connect only the first SIM or only the second SIM per time to the SIM interface of the modules as described in Figure 24. All LISA-U2 series modules support SIM hot insertion / removal on the GPIO5 pin: if the feature is enabled using the specific AT commands, the switch from first SIM to the second SIM can be properly done when a Low logic level is present on the GPIO5 pin (‘SIM not inserted’ = SIM interface not enabled), without the necessity of a module re-boot, so that the SIM interface will be re-enabled by the module to use the second SIM when an High logic level will be re-applied on the GPIO5 pin. (For more details see section 1.12 and to the u-blox AT Commands Manual [2], +UGPIOC, +UDCONF=50 commands.) In the application circuit represented in Figure 24, the application processor will drive the SIM switch using its own GPIO to properly select the SIM that is used by the module. Another GPIO may be used to handle the SIM hot insertion / removal function of LISA-U2 series modules, which can also be handled by other external circuits or by the cellular module GPIO according to the application requirements. The dual SIM connection circuit described in Figure 24 can be implemented for SIM chips as well, providing proper connection between SIM switch and SIM chip as described in Figure 22. If it is required to switch between more than two SIMs, a circuit similar to the one described in Figure 24 can be implemented: for example, in case of four SIM circuits, using a proper 4-pole 4-throw switch (or, alternatively, four 1-pole 4-throw switches) instead of the suggested 4-pole 2-throw switch. Follow these guidelines connecting the module to two SIM connectors: Use a proper low on resistance (i.e. few ohms) and low on capacitance (i.e. few pF) 2-throw analog switch (e.g. Fairchild FSA2567) as SIM switch to ensure high-speed data transfer according to SIM requirements. Connect the contacts C1 (VCC) and C6 (VPP) of the two UICC / SIM to the VSIM pin of the module by means of a proper 2-throw analog switch (e.g. Fairchild FSA2567). Connect the contact C7 (I/O) of the two UICC / SIM to the SIM_IO pin of the module by means of a proper 2-throw analog switch (e.g. Fairchild FSA2567). Connect the contact C3 (CLK) of the two UICC / SIM to the SIM_CLK pin of the module by means of a proper 2-throw analog switch (e.g. Fairchild FSA2567). Connect the contact C2 (RST) of the two UICC / SIM to the SIM_RST pin of the module by means of a proper 2-throw analog switch (e.g. Fairchild FSA2567). Connect the contact C5 (GND) of the two UICC / SIM to ground. Provide a 100 nF bypass capacitor (e.g. Murata GRM155R71C104K) at the SIM supply line (VSIM), close to the related pad of the two SIM connectors, to prevent digital noise. Provide a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) on each SIM line (VSIM, SIM_CLK, SIM_IO, SIM_RST), very close to each related pad of the two SIM connectors, to prevent RF coupling especially in case the RF antenna is placed closer than 10 - 30 cm from the SIM card holders. Provide a very low capacitance (i.e. less than 10 pF) ESD protection (e.g. Tyco Electronics PESD0402-140) on each externally accessible SIM line, close to each related pad of the two SIM connectors, according to the EMC/ESD requirements of the custom application. Limit capacitance and series resistance on each SIM signal (SIM_CLK, SIM_IO, SIM_RST) to match the requirements for the SIM interface (27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 µs is the maximum allowed rise time on the SIM_IO and SIM_RST lines). UBX-13001118 - R19 Early Production Information System description Page 50 of 175 LISA-U2 series - System Integration Manual FIRST SIM CARD LISA-U2 series VSIM 50 3V8 VPP (C6) 4PDT C11 Analog Switch VCC 1VSIM VSIM 2VSIM VCC (C1) SIM_IO 48 DAT 1DAT 2DAT SIM_CLK 47 CLK 1CLK 2CLK SIM_RST 49 RST 1RST 2RST IO (C7) CLK (C3) RST (C2) C1 C2 C3 C4 GND (C5) C5 D1 D2 D3 D4 J1 SECOND SIM CARD VPP (C6) SEL GND VCC (C1) U1 IO (C7) CLK (C3) Application Processor RST (C2) GPIO C6 R1 C7 C8 C9 C10 GND (C5) D5 D6 D7 D8 J2 Figure 24: Application circuit for the connection to two removable SIM cards, with SIM detection implemented Reference Description Part Number - Manufacturer C1 – C4, C6 – C9 33 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1H330JZ01 - Murata C5, C10, C11 D1 – D8 100 nF Capacitor Ceramic X7R 0402 10% 16 V Very Low Capacitance ESD Protection GRM155R71C104KA01 - Murata PESD0402-140 - Tyco Electronics R1 J1, J2 47 kΩ Resistor 0402 5% 0.1 W SIM Card Holder 6 positions, without card presence switch RC0402JR-0747KL- Yageo Phycomp Various Manufacturers, C707 10M006 136 2 - Amphenol U1 4PDT Analog Switch, with Low On-Capacitance and Low On-Resistance FSA2567 - Fairchild Semiconductor Table 25: Example of components for the connection to two removable SIM cards, with SIM detection implemented UBX-13001118 - R19 Early Production Information System description Page 51 of 175 LISA-U2 series - System Integration Manual 1.9 Serial communication LISA-U2 modules provide the following serial communication interfaces where AT command interface and Packet-Switched / Circuit-Switched Data communication are concurrently available: One asynchronous serial interface (UART) that provides complete RS-232 functionality conforming to ITU-T V.24 Recommendation [3], with limited data rate One Inter Processor Communication (IPC) interface that includes a synchronous SPI-compatible interface, with maximum data rate of 26 Mb/s One high-speed USB 2.0 compliant interface, with maximum data rate of 480 Mb/s. The LISA-U2 modules are designed to operate as an HSPA cellular modem, which represents the data circuitterminating equipment (DCE) as described by the ITU-T V.24 Recommendation [3]. A customer application processor connected to the module through one of the interfaces represents the data terminal equipment (DTE). All the interfaces listed above are controlled and operated with: AT commands according to 3GPP TS 27.007 [4] AT commands according to 3GPP TS 27.005 [5] AT commands according to 3GPP TS 27.010 [6] u-blox AT commands For the complete list of supported AT commands and their syntax see u-blox AT Commands Manual [2]. The module firmware can be upgraded over all the serial interfaces listed above by means of AT command (for more details see section 3.1 as well as the u-blox AT Commands Manual [2], +UFWUPD command). The module firmware can be upgraded over the following serial interfaces using the u-blox EasyFlash tool: The UART interface (only the RxD and TxD lines are needed) The USB interface (all the provided lines VUSB_DET, USB_D+ and USB_D- are needed) To directly enable PC (or similar) connection to the module for firmware upgrade using the u-blox EasyFlash tool, provide direct access on the application board to the VUSB_DET, USB_D+ and USB_Dlines of the module (or to the RxD and TxD lines). Also provide access to the PWR_ON or the RESET_N pins, or enable the DC supply connected to the VCC pin to start the module firmware upgrade (see Firmware Update Application Note [17]). The following sub-sections describe the serial interfaces configuration and provide a detailed description of each interface for the application circuits. UBX-13001118 - R19 Early Production Information System description Page 52 of 175 LISA-U2 series - System Integration Manual 1.9.1 Serial interfaces configuration UART, USB and SPI/IPC serial interfaces are available as AT command interface and for Packet-Switched / CircuitSwitched Data communication. The serial interfaces are configured as described in Table 26 (for information about further settings, see the u-blox AT Commands Manual [2]). Interface AT Settings Comments UART interface Enabled Multiplexing mode can be enabled by AT+CMUX command providing following channels: Channel 0: control channel Channel 1 – 5: AT commands / data connection Channel 6: GNSS tunneling Channel 7: SAP (SIM Access Profile) AT+IPR=0 AT+ICF=0 One-shot autobauding enabled by default One-shot frame format recognition enabled by default AT&K3 AT&S1 HW flow control enabled DSR line set ON in data mode and set OFF in command mode 5 AT&D1 AT&K3 Upon an ON-to-OFF transition of DTR, the DCE enters online command mode and issues an OK result code5 Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise 6 CDCs are available, configured as described in the following list: USB1: AT commands / data connection USB2: AT commands / data connection USB3: AT commands / data connection USB4: GPS tunneling USB5: Primary TraceLog USB6: Secondary TraceLog USB7: SAP (SIM Access Profile) HW flow control enabled AT&S1 DSR line set ON in data mode and set OFF in command mode 5 AT&D1 Upon an ON-to-OFF transition of DTR, the DCE enters online command mode and issues an OK result code5 Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise Multiplexing mode can be enabled by AT+CMUX command providing following channels: Channel 0: control channel Channel 1 – 5: AT commands / data connection Channel 6: GNSS tunneling Channel 7: SAP (SIM Access Profile) HW flow control enabled AT&C1 USB interface Enabled AT&C1 SPI interface Enabled AT&K3 AT&S1 AT&D1 AT&C1 DSR line set ON in data mode and set OFF in command mode5 Upon an ON-to-OFF transition of DTR, the DCE enters online command mode and issues an OK result code5 Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise Table 26: Default serial interfaces configuration Refer to the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode. UBX-13001118 - R19 Early Production Information System description Page 53 of 175 LISA-U2 series - System Integration Manual 1.9.2 Asynchronous serial interface (UART) The UART interface is a 9-wire unbalanced asynchronous serial interface that provides AT commands interface, PSD and CSD data communication. The module firmware can be upgraded over the UART interface using the u-blox EasyFlash tool or by means of AT command (for more details see section 3.1 and Firmware update application note [17]). UART interface provides RS-232 functionality conforming to the ITU-T V.24 Recommendation (more details available in ITU Recommendation [3]), with CMOS compatible signal levels: 0 V for low data bit or ON state, and 1.8 V for high data bit or OFF state. For detailed electrical characteristics see LISA-U2 series Data Sheet [1]. The LISA-U2 modules are designed to operate as an HSPA cellular modem, which represents the data circuitterminating equipment (DCE) as described by the ITU-T V.24 Recommendation [3]. A customer application processor connected to the module through the UART interface represents the data terminal equipment (DTE). The signal names of the LISA-U2 modules UART interface conform to the ITU-T V.24 Recommendation [3]. UART interfaces include the following lines: Name Description Remarks DSR Data set ready RI Ring Indicator DCD Data carrier detect DTR Data terminal ready Module output Circuit 107 (Data set ready) in ITU-T V.24 Module output Circuit 125 (Calling indicator) in ITU-T V.24 Module output Circuit 109 (Data channel received line signal detector) in ITU-T V.24 Module input Circuit 108/2 (Data terminal ready) in ITU-T V.24 Internal active pull-up to V_INT (1.8 V) enabled. RTS Ready to send Module hardware flow control input Circuit 105 (Request to send) in ITU-T V.24 Internal active pull-up to V_INT (1.8 V) enabled. CTS Clear to send TxD Transmitted data Module hardware flow control output Circuit 106 (Ready for sending) in ITU-T V.24 Module data input Circuit 103 (Transmitted data) in ITU-T V.24 Internal active pull-up to V_INT (1.8 V) enabled. RxD Received data GND Ground Module data output Circuit 104 (Received data) in ITU-T V.24 Table 27: UART interface signals The UART interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins, close to accessible points. UBX-13001118 - R19 Early Production Information System description Page 54 of 175 LISA-U2 series - System Integration Manual 1.9.2.1 UART features All flow control handshakes are supported by the UART interface and can be set by appropriate AT commands (see u-blox AT Commands Manual [2], &K, +IFC, \Q AT commands): hardware flow control (RTS/CTS), software flow control (XON/XOFF), or none flow control. Hardware flow control is enabled by default. One-shot autobauding is supported: the baud rate detection is performed once, at module start up. Then the module works at the fixed baud rate (the detected one) and the baud rate can only be changed via the appropriate AT command (+IPR, for more details see the u-blox AT Commands Manual [2]). In particular: If automatic baud rate detection is configured in the active memory profile, the baud rate is detected once at the module power-on The factory-programmed setting enables the automatic baud rate detection ( value is 0) Since autobauding is implemented as “one shot” autobauding, any setting of +IPR=0 should be avoided; the only exception is if the baud rate is fixed in the stored NVRAM profile. In this case, the module starts without autobauding and the host needs to reactivate it. If the system starts in autobauding (i.e. the +IPR is 0), the first “at” sequence provided to the module detects the baud rate. For example the first command sent from the DTE at any rate can be: AT+CPIN="1234".Characters different than “AT” are ignored during the baud rate detection since the “at” or “AT” sequence triggers the hardware detection sequence. “At” or “aT” sequences are invalid: both detection characters must be lowercase or uppercase. The module generates a response for the DTE once autobauding detection is successful, the command is accepted and the command response is available. Therefore, even if the detection was previously successful, it is only possible to assume that the detection phase was successful after a response. If the DTE does not receive any response after some time, it must retry (the timeout value should be adjustable inside the DTE application). In any case, use a very simple command as the first command, for which the execution time is short and almost constant (e.g. ATE). Note that the only way to recover from a detection failure is the detection reattempt, since the AT interface is only available after a successful detection. One-shot autobauding is enabled by factory programmed setting. The only way to recover from a detection failure is the detection reattempt, since the AT interface is only available after a successful detection. The following baud rates can be configured by AT command: 1200 b/s 2400 b/s 4800 b/s 9600 b/s 19200 b/s 38400 b/s 57600 b/s 115200 b/s, default value when the one-shot autobauding is disabled 230400 b/s 460800 b/s 921600 b/s 460800 b/s and 921600 b/s baud rates cannot be automatically detected by one-shot autobauding. UBX-13001118 - R19 Early Production Information System description Page 55 of 175 LISA-U2 series - System Integration Manual One-shot automatic frame recognition is supported and enabled in conjunction with the one-shot automatic baud rate detection only: when the one-shot autobauding is active, the one-shot automatic frame recognition is enabled overruling the frame format setting. The frame format recognition is performed once and then, after the successful recognition of the frame format, the automatic frame recognition is disabled, as the automatic baud rate detection. One-shot automatic frame recognition is enabled by default, as the one-shot autobauding. The following frame formats can be configured by AT command: 8N1 (8 data bits, No parity, 1 stop bit), default frame configuration with fixed baud rate 8E1 (8 data bits, even parity, 1 stop bit) 8O1 (8 data bits, odd parity, 1 stop bit) 8N2 (8 data bits, No parity, 2 stop bits) 7E1 (7 data bits, even parity, 1 stop bit) 7O1 (7 data bits, odd parity, 1 stop bit) The 8N2 frame format cannot be automatically detected by one-shot automatic frame recognition. The 8N1frame format, which is the default configuration with fixed baud rate, is described in the Figure 25. Normal Transfer, 8N1 Start of 1-Byte transfer D0 D1 Possible Start of next transfer D2 D3 D4 D5 Start Bit (Always 0) D6 D7 Stop Bit (Always 1) tbit = 1/(Baudrate) Figure 25: Description of UART default frame format (8N1) with fixed baud rate UBX-13001118 - R19 Early Production Information System description Page 56 of 175 LISA-U2 series - System Integration Manual 1.9.2.2 UART signal behavior See Table 5 for a description of operating modes and states referred to in this section. At the switch on of the module, before the initialization of the UART interface, as described in the power-on sequence reported in the Figure 18, each pin is first tri-stated and then is set to its specific internal reset state that is reported in the pin description table in LISA-U2 series Data Sheet [1]. At the end of the boot sequence, the UART interface is initialized, the module is by default in active mode and the UART interface is enabled. The configuration and the behavior of the UART signals after the boot sequence are described below. For a complete description of data and command mode, see the u-blox AT Commands Manual [2]. RxD signal behavior The module data output line (RxD) is set by default to OFF state (high level) at UART initialization. The module holds RxD in OFF state until no data is transmitted by the module. TxD signal behavior The module data input line (TxD) is set by default to OFF state (high level) at UART initialization. The TxD line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull -up is enabled inside the module on the TxD input. CTS signal behavior The module hardware flow control output (CTS line) is set to the ON state (low level) at UART initialization. If the hardware flow control is enabled, as it is by default, the CTS line indicates when the UART interface is enabled (data can be sent and received). The module drives the CTS line to the ON state or to the OFF state when it is either able or not able to accept data from the DTE over the UART (see 1.9.2.3 for more details). If hardware flow control is enabled, then when the CTS line is OFF it does not necessarily mean that the module is in low power idle-mode, but only that the UART is not enabled, as the module could be forced to stay in active-mode for other activities, e.g. related to the network or related to other interfaces. When the multiplexer protocol is active, the CTS line state is mapped to FCon / FCoff MUX command for flow control issues outside the power saving configuration while the physical CTS line is still used as a power state indicator. For more details, see Mux Implementation Application Note [15]. The CTS hardware flow control setting can be configured by AT commands (for more details, see u-blox AT Commands Manual [2], AT&K, AT\Q, AT+IFC, AT+UCTS AT command). If the hardware flow control is not enabled, the CTS line after the UART initialization behaves as follows: on LISA-U2 modules "01", "x2" and "68" product versions, the CTS line is always held in the ON state on LISA-U2 modules "03" product version onward, the CTS line is by default set in the ON state, but can be configured in the OFF state by the AT+UCTS command When the power saving configuration is enabled and the hardware flow-control is not implemented in the DTE/DCE connection, data sent by the DTE can be lost: the first character sent when the module is in the low power idle-mode will not be a valid communication character (see 1.9.2.3 for more details). UBX-13001118 - R19 Early Production Information System description Page 57 of 175 LISA-U2 series - System Integration Manual RTS signal behavior The hardware flow control input (RTS line) is set by default to the OFF state (high level) at UART initialization. The RTS line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the RTS input. If the HW flow control is enabled (for more details see the u-blox AT Commands Manual [2] AT&K, AT\Q, AT+IFC command description) the RTS line is monitored by the module to detect permission from the DTE to send data to the DTE itself. If the RTS line is set to OFF state, any on-going data transmission from the module is immediately interrupted or any subsequent transmission forbidden until the RTS line changes to ON state. The DTE must be able to still accept a certain number of characters after the RTS line has been set to OFF state: the module guarantees the transmission interruption within 2 characters from RTS state change. If AT+UPSV=2 is set and HW flow control is disabled, the RTS line is monitored by the module to manage the power saving configuration: When an OFF-to-ON transition occurs on the RTS input line, the UART is enabled and the module is forced to active-mode: after 20 ms from the transition the switch is completed and data can be received without loss. The module cannot enter idle-mode and the UART is keep enabled as long as the RTS input line is held in the ON state If RTS is set to OFF state by the DTE, the UART is immediately disabled (held in low power mode) and the module automatically enters idle-mode whenever possible For more details on the power saving configuration controlled by the RTS input line see section 1.9.2.3 and u-blox AT Commands Manual [2], AT+UPSV command. DSR signal behavior If AT&S0 is set, the DSR module output line is set by default to ON state (low level) at UART initialization and is then always held in the ON state. If AT&S1 is set, the DSR module output line is set by default to OFF state (high level) at UART initialization. The DSR line is then set to the OFF state when the module is in command mode or in online command mode and is set to the ON state when the module is in data mode (see the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode). The above behavior is valid for both Packet-Switched and Circuit-Switched Data transfer. DTR signal behavior The DTR module input line is set by default to OFF state (high level) at UART initialization. The DTR line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the DTR input. Module behavior according to DTR status depends on the AT command configuration (see u-blox AT Commands Manual [2], &D AT command). Except for “01” product version, if AT+UPSV=3 is set, the DTR line is monitored by the module to manage the power saving configuration: When an OFF-to-ON transition occurs on the DTR input line, the UART is enabled and the module is forced to active-mode: after 20 ms from the transition the switch is completed and data can be received without loss. The module cannot enter idle-mode and the UART is keep enabled as long as the DTR input line is held in the ON state If DTR is set to OFF state by the DTE, the UART is immediately disabled (held in low power mode) and the module automatically enters idle-mode whenever possible For more details on the power saving configuration controlled by the DTR input line see section 1.9.2.3 and u-blox AT Commands Manual [2], AT+UPSV command. UBX-13001118 - R19 Early Production Information System description Page 58 of 175 LISA-U2 series - System Integration Manual DCD signal behavior If AT&C0 is set, the DCD module output line is set by default to ON state (low level) at UART initialization and is then always held in the ON state. If AT&C1 is set, the DCD module output line is set by default to OFF state (high level) at UART initialization. The DCD line is then set by the module in accordance with the carrier detect status: ON if the carrier is detected, OFF otherwise. In case of voice call DCD is set to ON state when the call is established. For a data call there are the following scenarios (see the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode): PSD data call: Before activating the PPP protocol (data mode) a dial-up application must provide the ATD*99*** # to the module: with this command the module switches from command mode to data mode and can accept PPP packets. The module sets the DCD line to the ON state, then answers with a CONNECT to confirm the ATD*99 command. The DCD ON is not related to the context activation but with the data mode CSD data call: To establish a data call the DTE can send the ATD command to the module which sets an outgoing data call to a remote modem (or another data module). Data can be transparent (non reliable) or non transparent (with the reliable RLP protocol). When the remote DCE accepts the data call, the module DCD line is set to ON and the CONNECT string is returned by the module. At this stage the DTE can send characters through the serial line to the data module which sends them through the network to the remote DCE attached to a remote DTE In case of a voice call DCD is set to ON state on all the serial communication interfaces supporting the AT command interface. (including MUX virtual channels, if active). DCD is set to ON during the execution of a command requiring input data from the DTE (all the commands where a prompt is issued; see AT commands +CMGS, +CMGW, +USOWR, +USODL, +UDWNFILE in u-blox AT Commands Manual [2]). The DCD line is set to ON state as soon as the switch to binary/text input mode is completed and the prompt is issued; DCD line is set to OFF as soon as the input mode is interrupted or completed. DCD line is kept to ON state even during the online command mode to indicate that the data call is still established even if suspended, while if the module enters command mode DSR line is set to OFF state. For more details see the DSR signal behavior description. In case of scenarios for which the DCD line setting is requested for different reasons (e.g. SMS texting during online command mode), the DCD line changes to guarantee the correct behavior for all the scenarios. For instance, in case of SMS texting in online command mode, if the data call is released, the DCD line will be kept to ON till the SMS command execution is completed (even if the data call release would request the DCD setting to OFF). UBX-13001118 - R19 Early Production Information System description Page 59 of 175 LISA-U2 series - System Integration Manual RI signal behavior The RI module output line is set by default to the OFF state (high level) at UART initialization. Then, during an incoming call, the RI line is switched from OFF state to ON state with a 4:1 duty cycle and a 5 s period (ON for 1 s, OFF for 4 s, see Figure 26), until the DTE attached to the module sends the ATA string and the module accepts the incoming data call. The RING string sent by the module (DCE) to the serial port at constant time intervals is not correlated with the switch of the RI line to the ON state. 1s RI OFF RI ON 10 15 time [s] Call incomes Figure 26: RI behavior during an incoming call The RI line can notify an SMS arrival. When the SMS arrives, the RI line switches from OFF to ON for 1 s (see Figure 27), if the feature is enabled by the proper AT command (see the u-blox AT Commands Manual [2], AT+CNMI command). 1s RI OFF RI ON time [s] SMS arrives Figure 27: RI behavior at SMS arrival This behavior allows the DTE to stay in power saving mode until the DCE related event requests service. In case of SMS arrival, if several events occur coincidently or in quick succession each event triggers the RI line independently, although the line will not be deactivated between each event. As a result, the RI line may stay to ON for more than 1 s. If an incoming call is answered within less than 1 s (with ATA or if autoanswering is set to ATS0=1) than the RI line will be set to OFF earlier. As a result: RI line monitoring cannot be used by the DTE to determine the number of received SMSes. In case of multiple events (incoming call plus SMS received), the RI line cannot be used to discriminate the two events, but the DTE must rely on the subsequent URCs and interrogate the DCE with the proper commands. The RI line can additionally notify all the URCs and all the incoming data (PPP, Direct Link, sockets, FTP) on all LISA-U2 series modules except for “01” product version, if the feature is enabled by the proper AT command (see the u-blox AT Commands Manual [2], AT+URING command): the RI line is asserted when one of the configured events occur and it remains asserted for 1 s unless another configured event will happen, with the same behavior described in Figure 27. UBX-13001118 - R19 Early Production Information System description Page 60 of 175 LISA-U2 series - System Integration Manual 1.9.2.3 UART and power-saving The power saving configuration is controlled by the AT+UPSV command (for the complete description see the u-blox AT Commands Manual [2]). When power saving is enabled, the module automatically enters low power idle-mode whenever possible; otherwise the active-mode is maintained by the module (see section 1.4 for the definition and description of module operating modes). The AT+UPSV command configures both the module power saving and also the UART behavior in relation to the power saving. The conditions for the module entering idle-mode also depend on the UART power saving configuration. The AT+UPSV command can set these different power saving configurations: AT+UPSV=0, power saving disabled: module forced on active-mode and UART interface enabled (default) AT+UPSV=1, power saving enabled: module cyclic active / idle-mode and UART enabled / disabled AT+UPSV=2, power saving enabled and controlled by the UART RTS input line AT+UPSV=3, power saving enabled and controlled by the UART DTR input line The AT+UPSV=3 power saving configuration is not supported by “01” product version The different power saving configurations that can be set by the +UPSV AT command are described in details in the following subsections. UART interface communication process in the different power saving configurations, in relation with HW flow control settings and RTS input line status, is summarized in Table 28. For more details on the +UPSV AT command description, see the u-blox AT commands Manual [2]. AT+UPSV HW flow control RTS line DTR line Communication during idle-mode and wake up Enabled (AT&K3) ON ON or OFF Data sent by the DTE is correctly received by the module. Data sent by the module is correctly received by the DTE. Enabled (AT&K3) OFF ON or OFF Data sent by the DTE should be buffered by the DTE and will be correctly received by the module when RTS is set to ON. Data sent by the module is buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line will be ON). Disabled (AT&K0) ON or OFF ON or OFF Enabled (AT&K3) ON ON or OFF Data sent by the DTE is correctly received by the module. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise the data is lost. Data sent by the DTE should be buffered by the DTE and will be correctly received by the module when active-mode is entered. Data sent by the module is correctly received by the DTE. Enabled (AT&K3) OFF ON or OFF Data sent by the DTE is buffered by the DTE and will be correctly received by the module when active-mode is entered. Data sent by the module is buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line will be ON). Disabled (AT&K0) ON or OFF ON or OFF The first character sent by the DTE is lost, but after ~20 ms the UART and the module are waked up: recognition of subsequent characters is guaranteed after the complete UART / module wake-up. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. UBX-13001118 - R19 Early Production Information System description Page 61 of 175 LISA-U2 series - System Integration Manual AT+UPSV HW flow control RTS line DTR line Communication during idle-mode and wake up Enabled (AT&K3) ON or OFF ON or OFF Not Applicable: HW flow control cannot be enabled with AT+UPSV=2. Disabled (AT&K0) ON ON or OFF Disabled (AT&K0) OFF ON or OFF Enabled (AT&K3) ON ON Enabled (AT&K3) ON OFF Data sent by the DTE is correctly received by the module. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. Data sent by the DTE is lost by LISA-U2 modules. The first character sent by the DTE is lost by LISA-U2 modules, but after ~20 ms the UART and the module are waked up: recognition of subsequent characters is guaranteed after the complete UART / module wake-up. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. Data sent by the DTE is correctly received by the module. Data sent by the module is correctly received by the DTE. Data sent by the DTE is lost by the module. Data sent by the module is correctly received by the DTE. Enabled (AT&K3) OFF ON Data sent by the DTE is correctly received by the module. Data sent by the module is buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line will be ON). Enabled (AT&K3) OFF OFF Data sent by the DTE is lost by the module. Data sent by the module is buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line will be ON). Disabled (AT&K0) ON or OFF ON Data sent by the DTE is correctly received by the module. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. Disabled (AT&K0) ON or OFF OFF Data sent by the DTE is lost by the module. Data sent by the module is correctly received by the DTE if it is ready to receive data, otherwise data is lost. Table 28: UART and power-saving summary AT+UPSV=0: power saving disabled, fixed active-mode The module does not enter idle-mode and the UART interface is enabled (data can be sent and received): the CTS line is always held in the ON state after UART initialization. This is the default configuration. AT+UPSV=1: power saving enabled, cyclic idle/active mode When the DTE issues the AT+UPSV=1 command, the UART is immediately disabled. Afterwards, the UART of LISA-U2 series modules is periodically enabled to receive or send data and, if data has not been received or sent over the UART, the interface is automatically disabled whenever possible according to the timeout configured by the second parameter of the +UPSV AT command. The module automatically enters the low power idle-mode whenever possible but it wakes up to active-mode according to the UART periodic wake up so that the module cyclically enters the low power idle-mode and the active-mode. Additionally, the module wakes up to active-mode according to any required activity related to the network or any other required activity related to the functions / interfaces of the module. The UART is enabled, and the module does not enter low power idle-mode, in the following cases: During the periodic UART wake up to receive or send data If the module needs to transmit some data over the UART (e.g. URC) If a character is sent by the DTE with HW flow control disabled, the first character sent causes the system wake-up due to the “wake up via data reception” feature described in the following subsection, and the UART will be then kept enabled after the last data received according to the timeout set by the second parameter of the AT+UPSV=1 command The module, outside an active call, periodically wakes up from idle-mode to active-mode to monitor the paging channel of the current base station (paging block reception), according to 2G or 3G discontinuous reception (DRX) specification. UBX-13001118 - R19 Early Production Information System description Page 62 of 175 LISA-U2 series - System Integration Manual The time period between two paging receptions is defined by the current base station (i.e. by the network): If the module is registered with a 2G network, the paging reception period can vary from ~0.47 s (DRX = 2, i.e. 2 x 51 2G-frames) up to ~2.12 s (DRX = 9, i.e. 9 x 51 2G-frames) If the module is registered with a 3G network, the paging reception period can vary from 0.64 s (DRX = 6, i.e. 2 3G-frames) up to 5.12 s (DRX = 9, i.e. 2 3G-frames) The time period of the UART enable/disable cycle is configured differently when the module is registered with a 2G network compared to when the module is registered with a 3G network: 2G: the UART is enabled concurrently to a paging reception, and then, as data has not been received or sent, the UART is disabled until the first paging reception that occurs after a timeout of 2.0 s, and therefore the interface is enabled again 3G: the UART is asynchronously enabled to paging receptions, as the UART is enabled for ~20 ms, and then, if data are not received or sent, the UART is disabled for 2.5 s, and afterwards the interface is enabled again Not registered: when a module is not registered with a network, the UART is enabled for ~20 ms, and then, if data has not been received or sent, the UART is disabled for 2.5 s and afterwards the interface is enabled again The module active-mode duration outside an active call depends on: Network parameters, related to the time interval for the paging block reception (minimum of ~11 ms) Duration of UART enable time in absence of data reception (~20 ms) The time period from the last data received at the serial port during the active-mode: the module does not enter idle-mode until a timeout expires. The second parameter of the +UPSV AT command configures this timeout, from 40 2G-frames (i.e. 40 x 4.615 ms = 184 ms) up to 65000 2G-frames (i.e. 65000 x 4.615 ms = 300 s). Default value is 2000 2G-frames (i.e. 2000 x 4.615 ms = 9.2 s) The active-mode duration can be extended indefinitely since every subsequent character received during the active-mode, resets and restarts the timer. The timeout is ignored immediately after AT+UPSV=1 has been sent, so that the UART interface is disabled and the module may enter idle-mode immediately after the AT+UPSV=1 is sent The hardware flow-control output (CTS line) indicates when the UART interface is enabled (data can be sent and received over the UART), if HW flow control is enabled, as illustrated in Figure 28. Data input CTS OFF CTS ON time [s] 0.47- 2.10 s ~10 ms (min) ~9.2 s (default) UART disabled UART enabled UART enabled Figure 28: CTS behavior with power saving enabled (AT+UPSV=1) and HW flow control enabled: the CTS output line indicates when the UART interface of the module is enabled (CTS = ON = low level) or disabled (CTS = OFF = high level) UBX-13001118 - R19 Early Production Information System description Page 63 of 175 LISA-U2 series - System Integration Manual AT+UPSV=2: power saving enabled and controlled by the RTS line This configuration can only be enabled with the module hardware flow control disabled by AT&K0 command. The UART interface is immediately disabled after the DTE sets the RTS line to OFF. Then, the module automatically enters idle-mode whenever possible according to any required activity related to the network or any other required activity related to the functions / interfaces of the module. The UART is disabled as long as the RTS line is held to OFF, but the UART is enabled in case the module needs to transmit some data over the UART (e.g. URC). When an OFF-to-ON transition occurs on the RTS input line, the UART is re-enabled and the module, if it was in idle-mode, switches from idle to active-mode after ~20 ms: this is the UART and module “wake up time”. If the RTS line is set to ON by the DTE the module is not allowed to enter the low power idle-mode and the UART is kept enabled. AT+UPSV=3: power saving enabled and controlled by the DTR line The AT+UPSV=3 configuration can be enabled regardless the flow control setting on UART. In particular, the HW flow control can be enabled (AT&K3) or disabled (AT&K0) on UART during this configuration. The UART interface is immediately disabled after the DTE sets the DTR line to OFF. Then, the module automatically enters idle-mode whenever possible according to any required activity related to the network or any other required activity related to the functions / interfaces of the module. The UART is disabled as long as the DTR line is set to OFF, but the UART is enabled in case the module needs to transmit some data over the UART (e.g. URC). When an OFF-to-ON transition occurs on the DTR input line, the UART is re-enabled and the module, if it was in idle-mode, switches from idle to active mode after 20 ms: this is the UART and module “wake up time”. If the DTR line is set to ON by the DTE, the module is not allowed to enter idle-mode and the UART is kept enabled until the DTR line is set to OFF. When the AT+UPSV=3 configuration is enabled, the DTR input line can still be used by the DTE to control the module behavior according to AT&D command configuration (see u-blox AT Commands Manual [2]). The CTS output line indicates the UART power saving state as illustrated in Figure 28, if HW flow control is enabled with AT+UPSV=3. The AT+UPSV=3 power saving configuration is not supported by “01” product version. Wake up via data reception The UART wake up via data reception consists of a special configuration of the module TXD input line that causes the system wake-up when a low-to-high transition occurs on the TXD input line. In particular, the UART is enabled and the module switches from the low power idle-mode to active-mode within ~20 ms from the first character received: this is the system “wake up time”. As a consequence, the first character sent by the DTE when the UART is disabled (i.e. the wake up character) is not a valid communication character even if the wake up via data reception configuration is active, because it cannot be recognized, and the recognition of the subsequent characters is guaranteed only after the complete system wake-up (i.e. after ~20 ms). The UART wake up via data reception configuration is active in the following case: the TXD input line is configured to wake up the system via data reception only if AT+UPSV=1 is set with hardware flow control disabled UBX-13001118 - R19 Early Production Information System description Page 64 of 175 LISA-U2 series - System Integration Manual The UART wake up via data reception configuration is not active on the TXD input, and therefore all the data sent by the DTE is lost, if: AT+UPSV=2 is set with HW flow control disabled, and the RTS line is set OFF AT+UPSV=3 is set, regardless HW flow control setting, and the DTR line is set OFF Figure 29 and Figure 30 show examples of common scenarios and timing constraints: AT+UPSV=1 power saving configuration is active and the timeout from last data received to idle-mode start is set to 2000 frames (AT+UPSV=1,2000) Hardware flow control is disabled Figure 29 shows the case where the module UART is disabled and only a wake-up is forced. In this scenario the only character sent by the DTE is the wake-up character; as a consequence, the DCE module UART is disabled when the timeout from last data received expires (2000 frames without data reception, as the default case). UART DCE UART is enabled for 2000 GSM frames (~9.2 s) OFF ON time TXD input Wake up time: ~20 ms OFF ON Wake up character Not recognized by DCE time Figure 29: Wake-up via data reception without further communication UART DCE UART is enabled for 2000 GSM frames (~9.2s) after the last data received OFF ON time TXD input Wake up time: ~20 ms OFF ON Wake up character Not recognized by DCE Valid characters Recognized by DCE time Figure 30: Wake-up via data reception with further communication UBX-13001118 - R19 Early Production Information System description Page 65 of 175 LISA-U2 series - System Integration Manual Figure 30 shows the case where in addition to the wake-up character further (valid) characters are sent. The wake up character wakes-up the module UART. The other characters must be sent after the “wake up time” of ~20 ms. If this condition is satisfied, the module (DCE) recognizes characters. The module will disable the UART after 2000 GSM frames from the latest data reception. The “wake-up via data reception” feature cannot be disabled. In command mode , if autobauding is enabled and the DTE does not implement HW flow control, the DTE must always send a character to the module before the “AT” prefix set at the beginning of each command line: the first character is ignored if the module is in active-mode, or it represents the wake-up character if the module is in idle-mode. In command mode , if autobauding is disabled, the DTE must always send a dummy “AT” before each command line: the first character is not ignored if the module is in active-mode (i.e. the module replies “OK”), or it represents the wake up character if the module is in low power idle-mode (i.e. the module does not reply). No wake-up character or dummy “AT” is required from the DTE during a voice or data call since the module UART interface continues to be enabled and does not need to be woken-up. Furthermore in data mode a dummy “AT” would affect the data communication. Additional considerations The LISA-U2 series modules are forced to stay in active-mode if the USB is connected and not suspended, and therefore the AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 settings are overruled but they have effect on the UART behavior: they configure UART interface power saving, so that UART is enabled / disabled according to the AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 settings. To set the AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 configuration over the USB interface of LISA-U2 modules, the autobauding must be previously disabled on the UART by the +IPR AT command over the used AT interface (the USB), and this +IPR AT command configuration must be saved in the module’ non-volatile memory (see u-blox AT Commands Manual [2]). Then, after the subsequent module re-boot, AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 can be issued over the used AT interface (the USB): all the AT profiles are updated accordingly. Refer to the u-blox AT Commands Manual [2] for the definition of the interface data mode, command mode and online command mode. UBX-13001118 - R19 Early Production Information System description Page 66 of 175 LISA-U2 series - System Integration Manual 1.9.2.4 UART application circuits Providing the full RS-232 functionality (using the complete V.24 link) If RS-232 compatible signal levels are needed, to provide full RS-232 (9 lines) functionality two different external voltage translators (e.g. Maxim MAX3237E and Texas Instruments SN74AVC4T774) can be used. The Texas Instruments chips provide the translation from 1.8 V to 3.3 V, while the Maxim chip provides the translation from 3.3 V to RS-232 compatible signal level. If a 1.8V application processor is used, for complete RS-232 functionality conforming to ITU Recommendation [3] in DTE/DCE serial communication, the complete UART interface of the module (DCE) must be connected to a 1.8V DTE as described in Figure 31. Application processor (1.8V DTE) LISA-U2 series (1.8V DCE) TxD RxD RTS CTS 0Ω TP 0Ω 0Ω TP TP 0Ω TP 15 TXD 16 RXD 13 RTS 14 CTS DTR 12 DTR DSR DSR RI 10 RI DCD 11 DCD GND GND Figure 31: UART interface application circuit with complete V.24 link in DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 32. Application processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC C1 VCCA DIR1 DIR3 VCCB TxD A1 B1 RxD A2 B2 RTS A3 B3 CTS A4 B4 DIR2 DIR4 C3 VCCA C2 0Ω TP 0Ω 0Ω TP TP 0Ω TP V_INT 15 TXD 16 RXD 13 RTS 14 CTS OE GND U1 Unidirectional Voltage Translator 3V0 LISA-U2 series (1.8V DCE) 1V8 1V8 VCCB C4 DIR1 DTR A1 B1 DSR A2 B2 RI A3 B3 12 DTR 10 RI DCD A4 B4 11 DCD GND DIR2 DIR3 DIR4 OE GND GND DSR U2 Figure 32: UART interface application circuit with complete V.24 link in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2, C3, C4 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata U1, U2 Unidirectional Voltage Translator SN74AVC4T774 - Texas Instruments Table 29: Component for UART application circuit with complete V.24 link in DTE/DCE serial communication (3.0 V DTE) UBX-13001118 - R19 Early Production Information System description Page 67 of 175 LISA-U2 series - System Integration Manual Providing the TxD, RxD, RTS, CTS and DTR lines only (not using the complete V.24 link) If the functionality of the DSR, DCD and RI lines is not required, or the lines are not available: Leave DSR, DCD and RI lines of the module unconnected and floating If RS-232 compatible signal levels are needed, two different external voltage translators (e.g. Maxim MAX3237E and Texas Instruments SN74AVC4T774) can be used. The Texas Instruments chips provide the translation from 1.8 V to 3.3 V, while the Maxim chip provides the translation from 3.3 V to RS-232 compatible signal level. Figure 35 describes the circuit that should be implemented as if a 1.8 V Application Processor is used, given that the DTE will behave properly regardless DSR input setting. Application processor (1.8V DTE) LISA-U2 series (1.8V DCE) TxD 0Ω TP 0Ω 0Ω TP TP 0Ω TP 15 TXD 16 RXD 13 RTS 14 CTS DTR 12 DTR DSR DSR RI 10 RI DCD 11 DCD RxD RTS CTS GND GND Figure 33: UART interface application circuit with partial V.24 link (6-wire) in the DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output pin as 1.8 V supply, as described in Figure 34, given that the DTE will behave properly regardless DSR input setting. Application processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC VCCA DIR1 DIR3 C1 VCCB TxD A1 B1 RxD A2 B2 RTS A3 B3 CTS A4 B4 DIR2 DIR4 LISA-U2 series (1.8V DCE) 1V8 C2 0Ω TP 0Ω 0Ω TP TP 0Ω TP V_INT 15 TXD 16 RXD 13 RTS 14 CTS 12 DTR DSR OE GND U1 Unidirectional Voltage Translator 3V0 C3 DTR DSR VCCA DIR1 A1 A2 DIR2 1V8 C4 B1 B2 OE GND RI DCD VCCB 10 RI 11 U2 GND DCD GND Figure 34: UART interface application circuit with partial V.24 link (6-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2, C3, C4 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V Unidirectional Voltage Translator GRM155R61A104KA01 - Murata SN74AVC4T774 - Texas Instruments U2 Unidirectional Voltage Translator SN74AVC2T245 - Texas Instruments Table 30: Component for UART application circuit with partial V.24 link (6-wire) in DTE/DCE serial communication (3.0 V DTE) UBX-13001118 - R19 Early Production Information System description Page 68 of 175 LISA-U2 series - System Integration Manual If only TxD, RxD, RTS, CTS and DTR lines are provided (as implemented in Figure 33 and in Figure 34) and if HW flow-control is enabled (AT&K3, default setting), the power saving can be activated as it can be done when the complete UART link is provided (9-wire, as implemented in Figure 31 and in Figure 32), i.e. in these ways: AT+UPSV=1: the module automatically enters the low power idle-mode whenever possible and the UART interface is periodically enabled, as described in section 1.9.2.3, reaching low current consumption. With this configuration, when the module is in idle-mode, the data transmitted by the DTE will be buffered by the DTE and will be correctly received by the module when active-mode is entered. AT+UPSV=3: the module automatically enters the low power idle-mode whenever possible and the UART interface is enabled by the DTR line, as described in section 1.9.2.3, reaching very low current consumption. With this configuration, not supported by “01” product version, when the module is in idle-mode, the UART is re-enabled 20 ms after DTR has been set ON, and the recognition of subsequent characters is guaranteed until the module is in active-mode If the HW flow-control is disabled (AT&K0), it is recommended to enable the power saving in one of these ways: AT+UPSV=2: the module automatically enters the low power idle-mode whenever possible and the UART interface is enabled by the RTS line, as described in section 1.9.2.3, reaching very low current consumption. With this configuration, when the module is in idle-mode, the UART is re-enabled 20 ms after RTS has been set ON, and the recognition of subsequent characters is guaranteed until the module is in active-mode. AT+UPSV=3: the module automatically enters the low power idle-mode whenever possible and the UART interface is enabled by the DTR line, as described in section 1.9.2.3, reaching very low current consumption. With this configuration, not supported by “01” product version, when the module is in idle-mode, the UART is re-enabled 20 ms after DTR has been set ON, and the recognition of subsequent characters is guaranteed until the module is in active-mode. Providing the TxD, RxD, RTS and CTS lines only (not using the complete V.24 link) If the functionality of the DSR, DCD, RI and DTR lines is not required, or the lines are not available: Connect the module DTR input line to GND, to robustly fix the logic level Leave DSR, DCD and RI lines of the module unconnected and floating If RS-232 compatible signal levels are needed, the Maxim 13234E voltage level translator can be used. This chip translates voltage levels from 1.8 V (module side) to the RS-232 standard. Figure 35 describes the circuit that should be implemented as if a 1.8 V Application Processor is used. Application processor (1.8V DTE) TxD LISA-U2 series (1.8V DCE) 0Ω TP 0Ω 0Ω TP TP 0Ω TP 15 TXD 16 RXD 13 RTS 14 CTS DTR 12 DTR DSR DSR RI 10 RI DCD 11 DCD RxD RTS CTS GND GND Figure 35: UART interface application circuit with partial V.24 link (5-wire) in the DTE/DCE serial communication (1.8V DTE) UBX-13001118 - R19 Early Production Information System description Page 69 of 175 LISA-U2 series - System Integration Manual If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 36. Application processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC LISA-U2 series (1.8V DCE) 1V8 V_INT 15 TXD 16 RXD 13 RTS 14 CTS DTR 12 DTR DSR DSR RI 10 RI DCD 11 DCD C1 VCCA DIR1 DIR3 VCCB TxD A1 B1 RxD A2 B2 RTS A3 B3 CTS A4 DIR2 DIR4 B4 C2 0Ω TP 0Ω 0Ω TP TP 0Ω TP OE GND U1 GND GND Figure 36: UART interface application circuit with partial V.24 link (5-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V Unidirectional Voltage Translator GRM155R61A104KA01 - Murata SN74AVC4T774 - Texas Instruments Table 31: Component for UART application circuit with partial V.24 link (5-wire) in DTE/DCE serial communication (3.0 V DTE) If only TxD, RxD, RTS and CTS lines are provided, as implemented in Figure 35 and in Figure 36, and if HW flow-control is enabled (AT&K3, default setting), the power saving can be activated in this way: AT+UPSV=1: the module automatically enters the low power idle-mode whenever possible and the UART interface is periodically enabled, as described in section 1.9.2.3, reaching low current consumption. With this configuration, when the module is in idle-mode, data transmitted by the DTE will be buffered by the DTE and will be correctly received by the module when active-mode is entered. If the HW flow-control is disabled (AT&K0), it is recommended to enable the power saving in this way: AT+UPSV=2: the module automatically enters the low power idle-mode whenever possible and the UART interface is enabled by the RTS line, as described in section 1.9.2.3, reaching very low current consumption. With this configuration, when the module is in idle-mode, the UART is re-enabled 20 ms after RTS has been set ON, and the recognition of subsequent characters is guaranteed until the module is in active-mode. Providing the TxD and RxD lines only (not using the complete V24 link) If the functionality of the CTS, RTS, DSR, DCD, RI and DTR lines is not required in the application, or the lines are not available: Connect the module RTS input line to GND or to the CTS output line of the module: since the module requires RTS active (low electrical level) if HW flow-control is enabled (AT&K3, that is the default setting), the pin can be connected using a 0 Ω series resistor to GND or to the active module CTS (low electrical level) when the module is in active mode, the UART interface is enabled and the HW flow-control is enabled Connect the module DTR input line to GND, to robustly fix the logic level Leave DSR, DCD and RI lines of the module unconnected and floating UBX-13001118 - R19 Early Production Information System description Page 70 of 175 LISA-U2 series - System Integration Manual If RS-232 compatible signal levels are needed, the Maxim 13234E voltage level translator can be used. This chip translates voltage levels from 1.8 V (module side) to the RS-232 standard. Figure 37 describes the circuit that should be implemented as if a 1.8 V Application Processor is used. Application processor (1.8V DTE) LISA-U2 series (1.8V DCE) TxD RxD 0Ω TP 0Ω TP TP 0Ω RTS TP CTS DTR 15 TXD 16 RXD 13 RTS 14 CTS 12 DTR DSR RI DSR 10 RI DCD 11 DCD GND GND Figure 37: UART interface application circuit with partial V.24 link (3-wire) in the DTE/DCE serial communication (1.8V DTE) If a 3.0 V Application Processor is used, appropriate unidirectional voltage translators must be provided using the module V_INT output as 1.8 V supply, as described in Figure 38. Application processor (3.0V DTE) Unidirectional Voltage Translator 3V0 VCC C1 VCCA VCCB C2 DIR1 TxD A1 RxD A2 DIR2 U1 RTS CTS DTR DSR RI B1 B2 LISA-U2 series (1.8V DCE) 1V8 0Ω TP 0Ω TP 0Ω TP V_INT 15 TXD 16 RXD OE GND TP 13 RTS 14 CTS 12 DTR DSR 10 RI DCD 11 DCD GND GND Figure 38: UART interface application circuit with partial V.24 link (3-wire) in DTE/DCE serial communication (3.0 V DTE) Reference Description Part Number - Manufacturer C1, C2 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V Unidirectional Voltage Translator GRM155R61A104KA01 - Murata SN74AVC2T245 - Texas Instruments Table 32: Component for UART application circuit with partial V.24 link (3-wire) in DTE/DCE serial communication (3.0 V DTE) If only TxD and RxD lines are provided, as described in Figure 37 or in Figure 38, and HW flow-control is disabled (AT&K0), the power saving must be enabled in this way: AT+UPSV=1: the module automatically enters the low power idle-mode whenever possible and the UART interface is periodically enabled, as described in section 1.9.2.3, reaching low current consumption. With this configuration, when the module is in idle-mode, the UART is re-enabled 20 ms after the first data reception, and the recognition of subsequent characters is guaranteed until the module is in active-mode. If only TxD and RxD lines are provided, data delivered by the DTE can be lost with these settings: HW flow-control enabled in the module (AT&K3, that is the default setting) Module power saving enabled by AT+UPSV=1 HW flow-control disabled in the DTE UBX-13001118 - R19 Early Production Information System description Page 71 of 175 LISA-U2 series - System Integration Manual In this case the first character sent when the module is in idle-mode will be a wake-up character and will not be a valid communication character (see section 1.9.2.3 for the complete description). If power saving is enabled the application circuit with the TxD and RxD lines only is not recommended. During command mode the DTE must send to the module a wake-up character or a dummy “AT” before each command line (see section 1.9.2.3 for the complete description), but during data mode the wake-up character or the dummy “AT” would affect the data communication. Additional considerations If a 3.0 V Application Processor (DTE) is used, the voltage scaling from any 3.0 V output of the DTE to the apposite 1.8 V input of the module (DCE) can be implemented, as an alternative low-cost solution, by means of an appropriate voltage divider. Consider the value of the pull-up integrated at the input of the module (DCE) for the correct selection of the voltage divider resistance values and mind that any DTE signal connected to the module has to be tri-stated or set low when the module is in power-down mode and during the module poweron sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module (see the remark below).Moreover, the voltage scaling from any 1.8 V output of the cellular module (DCE) to the apposite 3.0 V input of the Application Processor (DTE) can be implemented by means of an appropriate low-cost non-inverting buffer with open drain output. The noninverting buffer should be supplied by the V_INT supply output of the cellular module. Consider the value of the pull-up integrated at each input of the DTE (if any) and the baud rate required by the application for the appropriate selection of the resistance value for the external pull-up biased by the application processor supply rail. If the module USB interface is connected to the application processor, it is highly recommended to provide direct access to RxD, TxD, CTS and RTS lines of the module for execution of firmware upgrade over UART using the u-blox EasyFlash tool and for debug purpose: testpoints can be added on the lines to accommodate the access and a 0 Ω series resistor must be mounted on each line to detach the module pin from any other connected device. Otherwise, if the USB interface is not connected to the application processor, it is highly recommended to provide direct access to VUSB_DET, USB_D+, USB_D- lines for execution of firmware upgrade over USB and for debug purpose. In both cases, provide as well access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the module firmware upgrade (see Firmware Update Application Note [17]). If the UART interface is not used, all the UART interface pins can be left unconnected, but it is highly recommended to provide direct access to the RxD, TxD, CTS and RTS lines for execution of firmware upgrade using the u-blox EasyFlash tool and for debug purpose. Any external signal connected to the UART interface must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the cellular module cannot be tri-stated, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode, when external reset is forced low and during power-on sequence. UBX-13001118 - R19 Early Production Information System description Page 72 of 175 LISA-U2 series - System Integration Manual 1.9.3 USB interface LISA-U2 modules provide a high-speed USB interface at 480 Mb/s compliant with the Universal Serial Bus Revision 2.0 specification [7]. It acts as a USB device and can be connected to any USB host such as a PC or other Application Processor. The USB-device shall look for all upper-SW-layers like any other serial device. This means that LISA-U2 modules emulate all serial control logical lines. Name Description Remarks VUSB_DET USB detect input Apply 5 V typical to enable USB USB_D+ USB Data Line D+ USB_D- USB Data Line D- 90 Ω nominal differential characteristic impedance (Z0) 30 Ω nominal common mode characteristic impedance (ZCM) Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [7] are part of the USB pad driver and need not be provided externally. 90 Ω nominal differential characteristic impedance (Z0) 30 Ω nominal common mode characteristic impedance (ZCM) Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [7] are part of the USB pad driver and need not be provided externally. Table 33: USB pins The USB interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting a very low capacitance (i.e. less or equal to 1 pF) ESD protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) on the lines connected to these pins, close to accessible points. 1.9.3.1 USB features LISA-U2 modules include a High-Speed USB 2.0 compliant interface with maximum data rate of 480 Mb/s between the module and a host processor. The module itself acts as a USB device and can be connected to any USB host such as a Personal Computer or an embedded application microprocessor for AT commands, data communication, FW upgrade by means of the FOAT feature, FW upgrade by means of the u-blox EasyFlash tool and for diagnostic purpose. The USB_D+/USB_D- lines carry the USB serial bus data and signaling, while the VUSB_DET input pin senses the VBUS USB supply presence (nominally +5 V at the source) to detect the host connection and enable the interface. The USB interface of the module is enabled only if a valid voltage is detected by the VUSB_DET input (see the LISA–U2 series Data Sheet [1]). Neither the USB interface, nor the whole module is supplied by the VUSB_DET input: the VUSB_DET senses the USB supply voltage and absorbs few microamperes. LISA-U2 series modules can provide the following functions over the USB interface: CDC-ACM for AT commands and data communication CDC-ACM for GNSS tunneling CDC-ACM for diagnostic CDC-ACM for SAP (SIM Access Profile) CDC-ECM for Ethernet-over-USB CDC-ECM for Ethernet-over-USB function is not supported by "01", "x2" and "68" product versions. UBX-13001118 - R19 Early Production Information System description Page 73 of 175 LISA-U2 series - System Integration Manual Each USB profile of LISA-U2 module identifies itself by its VID (Vendor ID) and PID (Product ID) combination, included in the USB device descriptor according to the USB 2.0 specifications [7]. If the USB interface is connected to the host before the module switch on, or if the module is reset with the USB interface connected to the host, the VID and PID are automatically updated runtime, after the USB detection. First, VID and PID are the following: VID = 0x058B PID = 0x0041 This VID and PID combination identifies a USB profile where no USB functions are available: AT commands must not be sent to the module over the USB profile identified by this VID and PID combination. Then, after a time period (roughly 5 s, depending on the host / device enumeration timings), the VID and PID are updated to the following ones, which are related to the LISA-U2 module default USB profile: VID = 0x1546 PID = 0x1102 The default configuration of the USB interface provides 7 USB CDC-ACM modem COM ports: USB1: AT and data USB2: AT and data USB3: AT and data USB4: GNSS tunneling USB5: Primary Log (diagnostic purpose) USB6: Secondary Log (diagnostic purpose) USB7: SAP (SIM Access Profile) The user can concurrently use the AT command interface on one CDC, and Packet-Switched / Circuit-Switched Data communication on another CDC. Figure 39 (left side) summarizes the USB end-points available with the default USB profile configuration. The USB interface of the LISA-U2 series can be configured by the AT+UUSBCONF command (for more details see the u-blox AT Commands Manual [2]) to select a different set of USB functions, available in a mutually exclusive way, and including 1 CDC-ECM for Ethernet-over-USB and 4 CDC-ACM modem COM ports enumerated as follows: USB1: AT and data USB2: GNSS tunneling USB3: Primary Log (diagnostic purpose) USB4: SAP (SIM Access Profile) The default profile of the USB interface cannot be changed on "01", "x2" and "68" product versions In the case of the USB profile with the set of functions described above, the VID and PID combination is the following: VID = 0x1546 PID = 0x1104 Figure 39 (right side) summarizes the USB end-points available with this alternative USB profile configuration. UBX-13001118 - R19 Early Production Information System description Page 74 of 175 LISA-U2 series - System Integration Manual Alternative profile configuration Default profile configuration Function AT and Data Function AT and Data Interface 0 Abstract Control Model EndPoint Interface 1 Interface 0 Abstract Control Model EndPoint Transfer: Interrupt Interface 1 Data Transfer: Interrupt Data EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk Function AT and Data Function GNSS tunneling Interface 2 Abstract Control Model EndPoint Interface 3 Interface 2 Abstract Control Model EndPoint Transfer: Interrupt Interface 3 Data Transfer: Interrupt Data EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk Function AT and Data Function Primary Log Interface 4 Abstract Control Model EndPoint Interface 5 Interface 4 Abstract Control Model EndPoint Transfer: Interrupt Interface 5 Data Transfer: Interrupt Data EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk Function GNSS tunneling Interface 6 Function SAP Abstract Control Model EndPoint Interface 7 Interface 6 Abstract Control Model EndPoint Transfer: Interrupt Interface 7 Data Transfer: Interrupt Data EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk Function Primary Log Function Ethernet Interface 8 Abstract Control Model EndPoint Interface 9 Interface 8 Transfer: Interrupt Data Ethernet Networking Control Model EndPoint Interface 9 Transfer: Interrupt Data On / Off EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk EndPoint Transfer: Bulk Function Secondary Log Interface 10 Abstract Control Model EndPoint Interface 11 Transfer: Interrupt Data EndPoint Transfer: Bulk EndPoint Transfer: Bulk Function SAP Interface 12 Abstract Control Model EndPoint Interface 13 Transfer: Interrupt Data EndPoint Transfer: Bulk EndPoint Transfer: Bulk Figure 39: LISA-U2 series end-points summary for the default and alternative USB profile configuration For more details on the configuration of the USB interface of LISA-U2 modules, see the u-blox AT Commands Manual [2], +UUSBCONF AT command. The module firmware can be upgraded over the USB interface using the u-blox EasyFlash tool or by means of AT command (for more details see section 3.12 and Firmware update application note [17]). UBX-13001118 - R19 Early Production Information System description Page 75 of 175 LISA-U2 series - System Integration Manual The USB drivers are available for the following operating system platforms: Windows XP Windows Vista Windows 7 Windows 8 Windows 8.1 Windows CE 5.0 Windows Embedded CE 6.0 Windows Embedded Compact 7 Windows Embedded Automotive 7 Windows Mobile 5 Windows Mobile 6 Windows Mobile 6.1 Windows Mobile 6.5 LISA-U2 modules are compatible with standard Linux/Android USB kernel drivers. 1.9.3.2 USB and power saving The modules automatically enter the USB suspended state when the device has observed no bus traffic for a specific time period according to the USB 2.0 specification [7]. In suspended state, the module maintains any USB internal status as device. In addition, the module enters the suspended state when the hub port it is attached to is disabled. This is referred to as USB selective suspend. If the USB is suspended and a power saving configuration is enabled by the AT+UPSV command, the module automatically enters the low power idle-mode whenever possible but it wakes up to active-mode according to any required activity related to the network (e.g. the periodic paging reception described in section 1.5.3.3) or any other required activity related to the functions / interfaces of the module. The USB exits suspend mode when there is bus activity. If the USB is connected and not suspended, the module is forced to stay in active-mode, therefore the AT+UPSV settings are overruled but they have effect on the power saving configuration of the other interfaces. The modules are capable of USB remote wake-up signaling: i.e. it may request the host to exit suspend mode or selective suspend by using electrical signaling to indicate remote wake-up, for example due to incoming call, URCs, data reception on a socket. The remote wake-up signaling notifies the host that it should resume from its suspended mode, if necessary, and service the external event. Remote wake-up is accomplished using electrical signaling described in the USB 2.0 specifications [7]. For the module current consumption description with power saving enabled and USB suspended, or with power saving disabled and USB not suspended, see the sections 1.5.3.3 and 1.5.3.4 and LISA-U2 series Data Sheet [1]. 1.9.3.3 USB application circuit Since the module acts as a USB device, the USB supply (5.0 V typ.) must be provided to VUSB_DET by the connected USB host. The USB interface is enabled only when a valid voltage as USB supply is detected by the VUSB_DET input. Neither the USB interface, nor the whole module is supplied by the VUSB_DET input: the VUSB_DET senses the USB supply voltage and absorbs few microamperes. The USB_D+ and USB_D- lines carry the USB serial data and signaling. The lines are used in single ended mode for relatively low speed signaling handshake, as well as in differential mode for fast signaling and data transfer. USB pull-up or pull-down resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0 specification [7] are part of the USB pad driver and do not need to be externally provided. UBX-13001118 - R19 Early Production Information System description Page 76 of 175 LISA-U2 series - System Integration Manual External series resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0 specification [7] are also integrated: characteristic impedance of USB_D+ and USB_D- lines is specified by the USB standard. The most important parameter is the differential characteristic impedance (Z0) applicable for odd-mode electromagnetic field, which should be as close as possible to 90 differential: signal integrity may be degraded if the PCB layout is not optimal, especially when the USB signaling lines are very long. The common mode characteristic impedance (ZCM) of each USB data line should be as close as possible to 30 . USB DEVICE CONNECTOR LISA-U2 series 18 VUSB_DET VBUS D+ 27 USB_D+ D- 26 USB_D- D1 D2 D3 C1 GND GND Figure 40: USB Interface application circuit Reference Description Part Number - Manufacturer D1, D2, D3 C2 Very Low Capacitance ESD Protection 100 nF Capacitor Ceramic X7R 0402 10% 16 V PESD0402-140 - Tyco Electronics GRM155R61A104KA01 - Murata Table 34: Component for USB application circuit If the USB interface is not connected to the application processor, it is highly recommended to provide direct access to the VUSB_DET, USB_D+, USB_D- lines for execution of firmware upgrade over USB using the u-blox EasyFlash tool and for debug purpose: testpoints can be added on the lines to accommodate the access. Otherwise, if the USB interface is connected to the application processor, it is highly recommended to provide direct access to the RxD, TxD, CTS and RTS lines for execution of firmware upgrade over UART and for debug purpose. In both cases, provide as well access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the module firmware upgrade (see Firmware Update Application Note [17]). If the USB interface is not used, the USB_D+, USB_D- and VUSB_DET pins can be left unconnected, but it is highly recommended to provide direct access to the lines for FW upgrade and debug purpose. UBX-13001118 - R19 Early Production Information System description Page 77 of 175 LISA-U2 series - System Integration Manual 1.9.4 SPI interface SPI is a master-slave protocol: the module runs as an SPI slave, i.e. it accepts AT commands on its SPI interface without specific configuration. The SPI-compatible synchronous serial interface cannot be used for FW upgrade. The standard 3-wire SPI interface includes two signals to transmit and receive data (SPI_MOSI and SPI_MISO) and a clock signal (SPI_SCLK). LISA-U2 modules provide two handshake signals (SPI_MRDY and SPI_SRDY), added to the standard 3-wire SPI interface, implementing the 5-wire Inter Processor Communication (IPC) interface. The purpose of the IPC interface is to achieve high speed communication (up to 26 Mb/s) between two processors following the same IPC specifications: the module baseband processor and an external processor. High speed communication is possible only if both sides follow the same Inter Processor Communication (IPC) specifications. The module firmware can be upgraded over the SPI interface by means of AT command (for more details see section 3.1 and Firmware Update application note [17]). Name Description Remarks SPI_MISO SPI Data Line. Master Input, Slave Output SPI_MOSI SPI Data Line. Master Output, Slave Input SPI_SCLK SPI Serial Clock. Master Output, Slave Input Module Output. Idle high. Shift data on rising clock edge (CPHA=1). Latch data on falling clock edge (CPHA=1). MSB is shifted first. Module Input. Idle high. Shift data on rising clock edge (CPHA=1). Latch data on falling clock edge (CPHA=1). MSB is shifted first. Internal active pull-up to V_INT (1.8 V) enabled. Module Input. Idle low (CPOL=0). Supported clock frequency: from 260 kHz up to 26 MHz. Internal active pull-down to GND enabled. SPI_MRDY SPI Master Ready to transfer data control line. Master Output, Slave Input SPI_SRDY SPI Slave Ready to transfer data control line. Master Input, Slave Output Module Input. Idle low. Internal active pull-down to GND enabled. Module Output. Idle low. Table 35: SPI interface signals The SPI interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting a low capacitance (i.e. less than 10 pF) ESD protection (e.g. AVX USB0002 varistor array) on the lines connected to these pins, close to accessible points. UBX-13001118 - R19 Early Production Information System description Page 78 of 175 LISA-U2 series - System Integration Manual 1.9.4.1 IPC communication protocol overview The module runs as an SPI slave, i.e. it accepts AT commands on its SPI interface without specific configuration. The SPI-device shall look for all upper-SW-layers like any other serial device. This means that LISA-U2 modules emulate all serial logical lines: the transmission and the reception of the data are similar to an asynchronous device. Two additional signals (SPI_MRDY and SPI_SRDY) are added to the SPI lines to communicate the state of readiness of the two processors: they are used as handshake signals to implement the data flow. The function of the SPI_MRDY and SPI_SRDY signals is twofold: For transmitting data the signal indicates to the data receiver that data is available to be transmitted For receiving data the signal indicates to the transmitter that the receiver is ready to receive data Due to this setup it is possible to use the control signals as interrupt lines waking up the receiving part when data is available for transfer. When the handshaking has taken place, the transfer occurs just as if it were a standard SPI interface without chip select functionality (i.e. one master - one slave setup). SPI_MRDY is used by the application processor (i.e. the master) to indicate to the module baseband processor (i.e. the slave) that it is ready to transmit or receive (IPC master ready signal), and can also be used by the application processor to wake up the module baseband processor if it is in idle-mode. SPI_SRDY line is used by the module baseband processor (i.e. the slave) to indicate to the application processor (i.e. the master) that it is ready to transmit or receive (IPC slave ready signal), and can also be used by the module baseband processor to wake up the application processor if it is in hibernation. SPI_MRDY SPI_SRDY DATA_EXCHANGE Header Data SPI_SCLK SPI_MOSI SPI_MISO Figure 41: IPC Data Flow: SPI_MRDY and SPI_SRDY line usage combined with the SPI protocol For the correct implementation of the SPI protocol, the frame size is known by both sides before a packet transfer of each packet. The frame is composed by a header with fixed size (always 4 bytes) and a payload with variable length (must be a multiple of 4 bytes). The same amount of data is exchanged in both directions simultaneously. Both sides set their readiness lines (SPI_MRDY / SPI_SRDY) independently when they are ready to transfer data. For the correct transmission of the data the other side must wait for the activating interrupt to allow the transfer of the other side. The master starts the clock shortly after SPI_MRDY and SPI_SRDY are set to active. The number of clock periods sent by the master is exactly that one of the frame-size to be transferred. The SPI_SRDY line will be set low after the master sets the clock line to idle state. The SPI_MRDY line is also set inactive after the clock line is set idle, but in case of a big transfer containing multiple packets, the SPI_MRDY line stays active. 1.9.4.2 IPC communication and power saving If power saving is enabled by AT command (AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3), the LISA-U2 module automatically enters idle-mode whenever possible, if the master indicates that it is not ready to transmit or receive by the SPI_MRDY signal, or if the LISA-U2 series module itself does not transfer data. UBX-13001118 - R19 Early Production Information System description Page 79 of 175 LISA-U2 series - System Integration Manual 1.9.4.3 IPC communication examples In the following, three IPC communication scenarios are described: Slave initiated data transfer, with a sleeping master Master initiated data transfer, with a sleeping slave Slave ended data transfer Slave initiated transfer with a sleeping master SPI_MRDY SPI_SRDY Header DATA EXCHG Data Header Figure 42: Data transfer initiated by LISA-U2 module (slave), with a sleeping application processor (master) When the master is sleeping (idle-mode), the following actions happen: 1. The slave indicates the master that is ready to send data by activating SPI_SRDY 2. When the master becomes ready to send, it signalizes this by activating SPI_MRDY 3. The master activates the clock and the two processors exchange the communication header and data 4. If the data has been exchanged, the slave deactivates SPI_SRDY to process the received information. The master does not need to de-assert SPI_MRDY as it controls the SPI_SCLK 5. After the preparation, the slave activates again SPI_SRDY and wait for SPI_SCLK activation. When the clock is active, all the data is transferred without intervention. If there is more data to transfer (flag set in any of the headers), the process will repeat from step 3 Master initiated transfer with a sleeping slave SPI_MRDY SPI_SRDY DATA EXCHG Header Data Header Figure 43: Data transfer initiated by application processor (master) with a sleeping LISA-U2 module (slave) When the slave is sleeping (idle-mode), the following actions happen: 1. The Master wakes the slave by setting the SPI_MRDY line active 2. As soon as the slave is awake, it signals it by activating SPI_SRDY 3. The master activates the clock and the two processors exchange the communication header and data UBX-13001118 - R19 Early Production Information System description Page 80 of 175 LISA-U2 series - System Integration Manual 4. If the data has been exchanged, the slave deactivates SPI_SRDY to process the received information. The master does not need to de-assert SPI_MRDY as it controls the SPI_SCLK 5. After the preparation, the slave activates again SPI_SRDY and wait for SPI_SCLK activation. When the clock is active, all data is transferred without intervention. If there is more data to transfer (flag set in any of the headers), the process will repeat from step 3 Slave ended transfer SPI_MRDY SPI_SRDY DATA EXCHG Header Data Figure 44: Data transfer terminated and then restarted by LISA-U2 module (slave) Starting from the state where data transfer is ongoing, the following actions will happen: 1. In case of the last transfer, the master will lower its SPI_MRDY line. After the data-transfer is finished the line must be low. If the slave has already set its SPI_SRDY line, the master must raise its line to initiate the next transfer (slave-waking-procedure) 2. If the data has been exchanged, the slave will deactivate SPI_SRDY to process the received information. This is the normal behavior 3. The slave will indicate the master that is ready to send data by activating SPI_SRDY 4. When the master is ready to send, it will signalize this by activating SPI_MRDY. This is optional, when SPI_MRDY is low before 5. The slave indicates immediately after a transfer termination that it is ready to start transmission again. In this case the slave will raise SPI_SRDY again. The SPI_MRDY line can be either high or low: the master has only to ensure that the SPI_SRDY change will be detected correctly via interrupt For more details regarding IPC communication protocol, see the SPI Application Note [18]. 1.9.4.4 IPC application circuits SPI_MOSI is the data line input for the module since it runs as SPI slave: it must be connected to the data line output (MOSI) of the application processor that runs as an SPI master. SPI_MISO is the data line output for the module since it runs as SPI slave: it must be connected to the data line input (MISO) of the application processor that runs as an SPI master. SPI_SCLK is the clock input for the module since it runs as SPI slave: it must be connected to the clock line output (SCLK) of the application processor that runs as an SPI master. SPI_MRDY is an input for the module able to detect an external interrupt which comes from the SPI master: it must be connected to a GPIO of the application processor that runs as an SPI master. SPI_SRDY is an output for the module that must be connected to a pin of the application processor that runs as an SPI master able to detect an external interrupt which comes from the module. Signal integrity of the high speed data lines may be degraded if the PCB layout is not optimal, especially when the SPI lines are very long: keep routing short and minimize parasitic capacitance to preserve signal integrity. It is recommended to match the length of SPI signals. UBX-13001118 - R19 Early Production Information System description Page 81 of 175 LISA-U2 series - System Integration Manual If a 1.8 V Application Processor is used, the SPI Master pins can be directly connected to the specific LISA-U2 SPI slave pins as described in Figure 45. It is recommended to tri-state the output pins of the SPI Master (i.e. set in high impedance mode) when LISA-U2 module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and allow a proper boot of the module. Application processor (1.8V SPI master) LISA-U2 series (1.8V SPI slave) MOSI 56 SPI_MOSI MISO 57 SPI_MISO SCLK 55 SPI_SCLK Interrupt 58 SPI_SRDY GPIO 59 SPI_MRDY GND GND Figure 45: IPC / SPI Interface application circuit connecting LISA-U2 series 1.8V SPI slave to a 1.8V SPI master If a 3.0 V SPI Master Application Processor is used, implement a circuit with appropriate unidirectional voltage translators with tri-state (i.e. high impedance) mode controlled by the application processor, as described in Figure 46. Application processor (3.0V SPI master) VCC Unidirectional Voltage Translator 3V0 VCCA DIR1 DIR3 C1 LISA-U2 series (1.8V SPI slave) 1V8 VCCB C2 V_INT MOSI A1 B1 56 SPI_MOSI MISO A2 B2 57 SPI_MISO SCLK A3 B3 55 SPI_SCLK A4 B4 OE DIR2 DIR4 GND U1 Unidirectional Voltage Translator 3V0 C3 VCCA 1V8 VCCB DIR2 C4 Interrupt A1 B1 58 SPI_SRDY GPIO A2 B2 59 SPI_MRDY GPIO OE U1 DIR1 GND GND GND U2 Figure 46: IPC / SPI Interface application circuit connecting LISA-U2 series 1.8V SPI slave to a 3.0V SPI master Reference Description Part Number - Manufacturer C1, C2, C3, C4 U1 100 nF Capacitor Ceramic X7R 0402 10% 16 V Unidirectional Voltage Translator GRM155R61A104KA01 - Murata SN74AVC4T774 - Texas Instruments U2 Unidirectional Voltage Translator SN74AVC2T245 - Texas Instruments Table 36: Components for IPC / SPI Interface application circuit connecting LISA-U2 series 1.8V SPI slave to a 3.0V SPI master UBX-13001118 - R19 Early Production Information System description Page 82 of 175 LISA-U2 series - System Integration Manual If the SPI/IPC interface is not used, the SPI_MOSI, SPI_MISO, SPI_SCLK, SPI_MRDY, SPI_SRDY pins can be left unconnected. Any external signal connected to the SPI / IPC interface must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the cellular module cannot be tri-stated, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode, when external reset is forced low and during power-on sequence. 1.9.5 MUX Protocol (3GPP 27.010) LISA-U2 modules have a software layer with MUX functionality, 3GPP TS 27.010 Multiplexer Protocol [6], available either on the UART or on the SPI physical link. The USB interface does not support the multiplexer protocol. This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE) and allows a number of simultaneous sessions over the used physical link (UART or SPI): the user can concurrently use AT command interface on one MUX channel and Packet-Switched / Circuit-Switched Data communication on another MUX channel. The multiplexer protocol can be used on one serial interface (UART or SPI) at a time. Each session consists of a stream of bytes transferring various kinds of data such as SMS, CBS, PSD, GNSS, AT commands in general. This permits, for example, SMS to be transferred to the DTE when a data connection is in progress. The following virtual channels are defined: Channel 0: control channel Channel 1 – 5: AT commands / data connection Channel 6: GNSS tunneling Channel 7: SAP (SIM Access Profile) For more details see the Mux implementation Application Note [15]. If the module switch off AT command +CPWROFF is issued over a multiplexer channel, the completion of the module power off sequence could require up to 2.5 s, after the module OK reply. Therefore, if the Application Processor (AP) controls the VCC supply of the module, the AP should disable the multiplexer protocol and then issue the AT+CPWROFF command over the used AT interface, or otherwise the AP should issue the AT+CPWROFF command over a multiplexer channel and wait 2.5 s after OK reception before removing the module VCC supply. UBX-13001118 - R19 Early Production Information System description Page 83 of 175 LISA-U2 series - System Integration Manual 1.10 DDC (I2C) interface 1.10.1 Overview An I C bus compatible Display Data Channel (DDC) interface for communication with u-blox GNSS receivers is available on LISA-U2 modules. The communication between a u-blox cellular module and a u-blox GNSS receiver is only provided by this DDC (I C) interface. Name Description Remarks SCL I2C bus clock line Open drain. External pull-up required. SDA I2C bus data line Open drain. External pull-up required. Table 37: DDC pins The DDC (I C) interface pins ESD sensitivity rating is 1 kV (HBM according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins, close to accessible points. u-blox has implemented special features in LISA-U2 series cellular modules to ease the design effort required for the integration of a u-blox cellular module with a u-blox GNSS receiver. Combining a u-blox cellular module with a u-blox GNSS receiver allows designers to have full access to the GNSS receiver directly via the cellular module: it relays control messages to the GNSS receiver via a dedicated DDC (I C) nd interface. A 2 interface connected to the GNSS receiver is not necessary: AT commands via the serial interfaces (UART, USB, SPI) of the cellular module allows a fully control of the GNSS receiver from any host processor. LISA-U2 modules feature embedded GPS aiding that is a set of specific features developed by u-blox to enhance GNSS performance, decreasing Time To First Fix (TTFF), thus allowing to calculate the position in a shorter time with higher accuracy. The DDC (I C) interface of all LISA-U2 series modules can be used to communicate with u-blox GNSS receivers and with external I C devices as an audio codec: the cellular module acts as an I C master which can communicate to more I C slaves as allowed by the I C bus specifications [8]. See section 1.11 for an application circuit with an external audio codec. For more details regarding the handling of the DDC (I C) interface and the GPS aiding features, see the u-blox AT Commands Manual [2] (AT+UGPS, AT+UGPRF, AT+UGPIOC, +UI2CO, +UI2CW, +UI2CR, +UI2CREGR, +UI2CC AT commands) and GNSS Implementation Application Note [16]. 1.10.2 DDC application circuits 1.10.2.1 General considerations The DDC I C-bus master interface of LISA-U2 series modules can be used to communicate with u-blox GNSS receivers and with other external I C-bus slaves as an audio codec: beside the general considerations reported below, see the section 1.10.2.2 for specific guidelines and application circuit examples for the connection to u2 blox GNSS receivers and see the section 1.11 for an application circuit example with an external audio codec I Cbus slave. UBX-13001118 - R19 Early Production Information System description Page 84 of 175 LISA-U2 series - System Integration Manual To be compliant to the I C bus specifications, the module bus interface pads are open drain output and pull up resistors must be mounted externally. Resistor values must conform to the I C bus specifications [8]: for example, 4.7 k resistors can be commonly used. Pull-ups must be connected to a supply voltage of 1.8 V (typical), since this is the voltage domain of the DDC pins which are not tolerant to higher voltage values (e.g. 3.0 V). Connect the DDC (I C) pull-ups to the V_INT 1.8 V supply source, or another 1.8 V supply source enabled after V_INT (e.g., as the GNSS 1.8 V supply present in Figure 47 application circuit), as any external signal connected to the DDC (I C) interface must not be set high when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least until the switch on of the V_INT supply of DDC pins), to avoid latch-up of circuits and let a proper boot of the module. See Figure 18 for power-on sequence description and timings. DDC Slave-mode operation is not supported, the module can act as master only. Two lines, serial data (SDA) and serial clock (SCL), carry information on the bus. SCL is used to synchronize data transfers, and SDA is the data line. Since both lines are open drain outputs, the DDC devices can only drive them low or leave them open. The pull-up resistor pulls the line up to the supply rail if no DDC device is pulling it down to GND. If the pull-ups are missing, SCL and SDA lines are undefined and the DDC bus will not work. The signal shape is defined by the values of the pull-up resistors and the bus capacitance. Long wires on the bus will increase the capacitance. If the bus capacitance is increased, use pull-up resistors with nominal resistance value lower than 4.7 k, to match the I C bus specifications [8] regarding rise and fall times of the signals. Capacitance and series resistance must be limited on the bus to match the I C specifications (1.0 µs is the maximum allowed rise time on the SCL and SDA lines): route connections as short as possible. If the pins are not used as DDC bus interface, they can be left unconnected. 1.10.2.2 Connection with u-blox GNSS receivers General considerations LISA-U2 modules support these GPS aiding types: Local aiding AssistNow Online AssistNow Offline AssistNow Autonomous The embedded GPS aiding features can be used only if the DDC (I C) interface of the cellular module is connected to the u-blox GNSS receivers. The GPIO pins of LISA-U2 series modules can handle: GNSS receiver power-on/off (“GNSS supply enable” function provided by GPIO2) The wake up from idle-mode when the GNSS receiver is ready to send data (“GNSS data ready” function provided by GPIO3) The RTC synchronization signal to the GNSS receiver (“GNSS RTC sharing” function provided by GPIO4) The GPIO2 is by default configured to provide the “GNSS supply enable” function (parameter of AT+UGPIOC command set to 3 by default), to enable or disable the supply of the u-blox GNSS receiver connected to the cellular module by the AT+UGPS command. The pin is set a Output / High, to switch on the u-blox GNSS receiver, if the parameter of AT+UGPS command is set to 1 Output / Low, to switch off the u-blox GNSS receiver, if the parameter of AT+UGPS command is set to 0 (default setting) The pin must be connected to the active-high enable pin (or the active-low shutdown pin) of the voltage regulator that supplies the u-blox GNSS receiver on the application board. UBX-13001118 - R19 Early Production Information System description Page 85 of 175 LISA-U2 series - System Integration Manual The “GNSS supply enable” function improves the power consumption of the GNSS receiver. When the GNSS functionality is not required, the GNSS receiver can be completely switched off by the cellular module that is controlled by the application processor with AT commands. The GPIO3 is by default configured to provide the “GNSS data ready” function (parameter of AT+UGPIOC command set to 4 by default), to sense when the u-blox GNSS receiver connected to the cellular module is ready to send data by the DDC (I C) interface. The pin will be set as Input, to sense the line status, waking up the cellular module from idle-mode when the u-blox GNSS receiver is ready to send data by the DDC (I C) interface, if the parameter of +UGPS AT command is set to 1 and the parameter of +UGPRF AT command is set to 16 Tri-state with an internal active pull-down enabled, otherwise (default setting) The pin that provides the “GNSS data ready” function must be connected to the data ready output of the u-blox GNSS receiver (i.e. the pin TxD1 of the u-blox GNSS receiver) on the application board. The “GNSS data ready” function provides an improvement in the power consumption of the cellular module. When power saving is enabled in the cellular module by the AT+UPSV command and the GNSS receiver does not send data by the DDC (I C) interface, the module automatically enters idle-mode whenever possible. With the “GNSS data ready” function the GNSS receiver can indicate to the cellular module that it is ready to send data by the DDC (I C) interface: the GNSS receiver can wake up the cellular module if it is in idle-mode, so that data sent by the GNSS receiver will not be lost by the cellular module even if power saving is enabled. The GPIO4 is by default configured to provide the “GNSS RTC sharing” function (parameter of +UGPIOC AT command set to 5), to provide an RTC (Real Time Clock) synchronization signal at the power up of the u-blox GNSS receiver connected to the cellular module. The pin will be set as Output, to provide an RTC synchronization signal to the u-blox GNSS receiver for RTC sharing if the parameter of AT+UGPS command is set to 1 and the parameter of +UGPRF AT command is set to 32 Output / Low, otherwise (default setting) The pin that provides the “GNSS RTC sharing” function must be connected to the RTC synchronization signal of the u-blox GNSS receiver (i.e. the pin EXTINT0 of the u-blox GNSS receiver) on the application board. The “GNSS RTC sharing” function provides improved GNSS receiver performance, decreasing the Time To First Fix (TTFF), and thus allowing to calculate the position in a shorter time with higher accuracy. When GPS local aiding is enabled, the cellular module automatically uploads data such as position, time, ephemeris, almanac, health and ionospheric parameter from the GNSS receiver into its local memory, and restores this to the GNSS receiver at the next power up of the GNSS receiver. Connection with u-blox 1.8 V GNSS receivers Figure 47 shows an application circuit for connecting a LISA-U2 cellular module to a u-blox 1.8 V GNSS receiver. SDA and SCL pins of the LISA-U2 cellular module are directly connected to the relative I C pins of the u-blox 1.8 V GNSS receiver, with appropriate pull-up resistors connected to the 1.8 V GNSS supply enabled after the V_INT supply of the I C pins of the LISA-U2 cellular module. GPIO3 and GPIO4 pins are directly connected respectively to the TxD1 and EXTINT0 pins of the u-blox 1.8 V GNSS receiver to provide “GNSS data ready” and “GNSS RTC sharing” functions. A pull-down resistor is mounted on GPIO4 line for correct “GNSS RTC sharing” function implementation. A pull-down resistor is mounted on the GPIO2 line to avoid a switch on of the u-blox GNSS receiver when the LISA-U2 module is in the internal reset state. The V_BCKP supply output of the LISA-U2 cellular module is connected to the V_BCKP backup supply input pin of the GNSS receiver to provide the supply for the GNSS real time clock and backup RAM when the VCC supply of the cellular module is within its operating range and the VCC supply of the GNSS receiver is disabled. This enables the u-blox GNSS receiver to recover from a power breakdown with either a hot start UBX-13001118 - R19 Early Production Information System description Page 86 of 175 LISA-U2 series - System Integration Manual or a warm start (depending on the duration of the GNSS VCC outage) and to maintain the configuration settings saved in the backup RAM. “GNSS data ready” and “GNSS RTC sharing” functions are not supported by all u-blox GNSS receivers HW or ROM/FW versions. See the GNSS Implementation Application Note [16] or to the Hardware Integration Manual of the u-blox GNSS receivers for the supported features. u-blox GNSS 1.8 V receiver LISA-U2 series V_BCKP GPS LDO Regulator 1V8 VCC OUT 1V8 1V8 IN 21 SHDN C1 V_BCKP VMAIN GND GPIO2 R3 U1 R1 R2 SDA2 46 SDA SCL2 45 SCL TxD1 23 GPIO3 EXTINT0 24 GPIO4 R4 Figure 47: DDC Application circuit for u-blox 1.8 V GNSS receiver Reference Description Part Number - Manufacturer R1, R2, R4 R3 4.7 kΩ Resistor 0402 5% 0.1 W 47 kΩ Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp RC0402JR-0747KL - Yageo Phycomp U1 Voltage Regulator for GNSS receiver See GNSS receiver Hardware Integration Manual Table 38: Components for DDC application circuit for u-blox 1.8 V GNSS receiver As an alternative to using an external voltage regulator, the V_INT supply output of LISA-U2 cellular modules can be used to supply a u-blox 1.8 V GNSS receiver of the u-blox 6 generation (or later u-blox generation). The V_INT supply is able to withstand the maximum current consumption of these positioning receivers. The V_INT supply output provides low voltage ripple (up to 15 mVpp) when the module is in active-mode or in connected-mode, but it provides higher voltage ripple (up to 70 mVpp) when the module is in the low power idle-mode with power saving configuration enabled by AT+UPSV (see the u-blox AT Commands Manual [2]). According to the voltage ripple characteristic of the V_INT supply output: The power saving configuration cannot be enabled to use V_INT output to properly supply any 1.8 V GNSS receiver of the u-blox 6 generation and any 1.8 V GNSS receiver of the u-blox 7 generation or any newer u-blox GNSS receiver generation with TCXO. The power saving configuration can be enabled to use V_INT output to properly supply any 1.8 V GNSS receiver of the u-blox 7 generation or any newer u-blox GNSS receiver generation without TCXO. Additional filtering may be needed to properly supply an external LNA, depending on the characteristics of the used LNA, adding a series ferrite bead and a bypass capacitor (e.g. the Murata BLM15HD182SN1 ferrite bead and the Murata GRM1555C1H220J 22 pF capacitor) at the input of the external LNA supply line. See the GNSS Implementation Application Note [16] for additional guidelines using the V_INT supply output of LISA-U2 cellular modules to supply a u-blox 1.8 V GNSS receiver. UBX-13001118 - R19 Early Production Information System description Page 87 of 175 LISA-U2 series - System Integration Manual Connection with u-blox 3.0 V GNSS receivers Figure 48 shows an application circuit for connecting a LISA-U2 cellular module to a u-blox 3.0 V GNSS receiver: As the SDA and SCL pins of the LISA-U2 cellular module are not tolerant up to 3.0 V, the connection to the related I C pins of the u-blox 3.0 V GNSS receiver must be provided using a proper I C-bus Bidirectional Voltage Translator (e.g. TI TCA9406, which additionally provides the partial power down feature so that the GNSS 3.0 V supply can be ramped up before the V_INT 1.8 V cellular supply), with proper pull-up resistors. As the GPIO3 and GPIO4 pins of the LISA-U2 cellular module are not tolerant up to 3.0 V, the connection to the related pins of the u-blox 3.0 V GNSS receiver must be provided using a proper Unidirectional General Purpose Voltage Translator (e.g. TI SN74AVC2T245, which additionally provides the partial power down feature so that the 3.0 V GNSS supply can be also ramped up before the V_INT 1.8 V cellular supply). The V_BCKP supply output of the cellular module can be directly connected to the V_BCKP backup supply input pin of the GNSS receiver as in the application circuit for a u-blox 1.8 V GNSS receiver. u-blox GNSS 3.0 V receiver LISA-U2 series V_BCKP GPS LDO Regulator 3V0 VCC OUT GND 21 GPIO2 V_INT R3 U1 I2C-bus Bidirectional Voltage Translator VCCB 1V8 VCCA OE C2 R1 V_BCKP IN SHDN C1 VMAIN C3 R2 R4 R5 SDA2 SDA_B SDA_A 46 SDA SCL2 SCL_B SCL_A 45 SCL GND U2 3V0 Unidirectional Voltage Translator VCCA 1V8 VCCB C4 C5 DIR1 TxD1 A1 B1 23 GPIO3 EXTINT0 A2 B2 24 GPIO4 DIR2 GND OE R7 U3 Figure 48: DDC Application circuit for u-blox 3.0 V GNSS receiver Reference Description Part Number - Manufacturer R1, R2, R4, R5, R7 4.7 kΩ Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp R3 C2, C3, C4, C5 47 kΩ Resistor 0402 5% 0.1 W 100 nF Capacitor Ceramic X5R 0402 10% 10V RC0402JR-0747KL - Yageo Phycomp GRM155R71C104KA01 - Murata U1, C1 See GNSS receiver Hardware Integration Manual U2 Voltage Regulator for GNSS receiver and related output bypass capacitor I2C-bus Bidirectional Voltage Translator U3 Generic Unidirectional Voltage Translator SN74AVC2T245 - Texas Instruments TCA9406DCUR - Texas Instruments Table 39: Components for DDC application circuit for u-blox 3.0 V GNSS receiver UBX-13001118 - R19 Early Production Information System description Page 88 of 175 LISA-U2 series - System Integration Manual 1.11 Audio Interface All LISA-U2 series modules provide two bidirectional 4-wire I S digital audio interfaces for connecting to remote digital audio devices: First 4-wire I S digital audio interface (I2S_CLK, I2S_RXD, I2S_TXD and I2S_WA) Second 4-wire I S digital audio interface (I2S1_CLK, I2S1_RXD, I2S1_TXD and I2S1_WA) Audio signal routing can be controlled by the dedicated AT command +USPM (see the u-blox AT Commands Manual [2]). This command allows setting the audio path mode, composed by the uplink audio path and the downlink audio path. Each uplink and downlink path mode defines the physical input / output, the set of parameters to process the uplink audio signal (uplink gains, uplink digital filters, echo canceller parameters) and the set of parameters to process the downlink audio signal (downlink gains, downlink digital filters and sidetone). The set of parameters to process the uplink or the downlink audio signal can be changed with dedicated AT commands for each uplink or downlink path and then stored in two profiles in the non volatile memory (see the u-blox AT Commands Manual [2] for audio parameters tuning commands). LISA-U2 series modules can act as I S master or I S slave. In master mode the word alignment and clock signals of the I S digital audio interface are generated by the module. In slave mode these signal must be generated by the remote device. Table 40 lists the signals related to digital audio function. Name Description Remarks I2S_TXD I2S transmit data Module output I2S_RXD I2S_CLK I2S receive data I2S clock I2S_WA I2S word alignment Module input Module output in master mode Module input in slave mode Module output in master mode Module input in slave mode I2S1_TXD I2S1_RXD Second I2S transmit data Second I2S receive data Module output Module input I2S1_CLK Second I2S clock Module output in master mode Module input in slave mode Module output in master mode Module input in slave mode Digital clock output for external audio codec Configurable to 26 MHz or 13 MHz I2S1_WA Second I S word alignment CODEC_CLK Digital clock output Table 40: Digital audio interface pins The I S interfaces and CODEC_CLK pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting a general purpose ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to the I S interfaces pins, close to accessible points, and a low capacitance (i.e. less than 10 pF) ESD protection (e.g. AVX USB0002) on the line connected to CODEC_CLK pin, close to accessible point. The I S interface can be set to two modes, by the parameter of the AT+UI2S command: PCM mode Normal I S mode UBX-13001118 - R19 Early Production Information System description Page 89 of 175 LISA-U2 series - System Integration Manual The I S interface can be set to two configurations, by the parameter of AT+UI2S: Master mode Slave mode The sample rate of transmitted/received words can be set, by the parameter of AT+UI2S, to: 8 kHz 11.025 kHz 12 kHz 16 kHz 22.05 kHz 24 kHz 32 kHz 44.1 kHz 48 kHz The and parameters of the AT+USPM command must be properly configured to select the I S digital audio interfaces paths (for more details see the u-blox AT Commands Manual [2]): has to be properly set to select: the first I S interface (using I2S_RXD module input) the second I S interface (using I2S1_RXD module input) has to be properly set to select: the first I S interface (using I2S_TXD module output) the second I S interface (using I2S1_TXD module output) Parameters of digital path can be configured and saved as the normal analog paths, using appropriate path parameter as described in the u-blox AT Commands Manual [2], +USGC, +UMGC, +USTN AT command. Analog gain parameters are not used. The I S receive data input and the I S transmit data output signals can use the following resources: Digital filters and digital gains are available in both uplink and downlink direction. They can be properly configured by the AT commands Ringer tone and service tone are mixed on the TX path when active (downlink) The HF algorithm acts on I S path See the u-blox AT Commands Manual [2] (AT+UI2S command) for the possible settings of I S interface. 1.11.1 I S interface - PCM mode Main features of the I S interface in PCM mode: I S runs in PCM - short alignment mode (configurable by AT commands) I S word alignment signal can be configured to 8, 11.025, 12, 16, 22.05, 24, 32, 44.1, 48 kHz I S word alignment toggles high for 1 or 2 CLK cycles of synchronization (configurable), then toggles low for 16 CLK cycles of sample width. Frame length can be 1 + 16 = 17 bits or 2 + 16 = 18 bits I S clock frequency depends on frame length and . Can be 17 x or 18 x I S transmit and I S receive data are 16 bit words long with the same sampling rate as I S word alignment, mono. Data is in 2’s complement notation. MSB is transmitted first UBX-13001118 - R19 Early Production Information System description Page 90 of 175 LISA-U2 series - System Integration Manual When I S word alignment toggles high, the first synchronization bit is always low. Second synchronization bit (present only in case of 2 bit long I S word alignment configuration) is MSB of the transmitted word (MSB is transmitted twice in this case) I S transmit data changes on I S clock rising edge, I S receive data changes on I S clock falling edge 1.11.2 I2S interface - Normal I2S mode Normal I S supports: 16 bits word Mono interface Configurable sample rate: 8, 11.025, 12, 16, 22.05, 24, 32, 44.1, 48 kHz Main features of I S interface in normal I S mode: I S word alignment signal always runs at and synchronizes 2 channels (timeslots on word alignment high, word alignment low) I S transmit data is composed of 16 bit words, dual mono (the words are written on both channels). Data are in 2’s complement notation. MSB is transmitted first. The bits are written on I S clock rising or falling edge (configurable) I S receive data is read as 16 bit words, mono (words are read only on the timeslot with WA high). Data is read in 2’s complement notation. MSB is read first. The bits are read on the I S clock edge opposite to I S transmit data writing edge (configurable) I S clock frequency is 16 bits x 2 channels x The modes are configurable through a specific AT command (see the u-blox AT Commands Manual [2], +UI2S AT command) and the following parameters can be set: MSB can be 1 bit delayed or non-delayed on I S word alignment edge I S transmit data can change on rising or falling edge of I S clock signal (rising edge in this example) I S receive data are read on the opposite front of I S clock signal 1.11.3 I2S interface application circuits LISA-U2 I S digital audio interfaces can be connected to an external digital audio device for voice applications. Any external digital audio device compliant to the configuration of the digital audio interface of the cellular module can be used, given that the external digital audio device has to provide: The opposite role: slave or master for LISA-U2 modules that may act as master or slave The same mode and frame format: PCM / short alignment or Normal I S mode / long alignment mode with data in 2’s complement notation MSB transmitted first word length = 16-bit frame length = 17-bit or 18-bit in PCM / short alignment mode (16 + 1 or 16 + 2 clock cycles, with Word Aligment / Synchronization signal set high for 1 clock cycle or 2 clock cycles), or frame length = 32-bit in Normal I S mode / long alignment mode (16 x 2 clock cycles) The same sample rate and serial clock frequency: as the clock frequency depends on the frame length and the sample rate, the clock frequency can be o 17 x or 18 x in PCM / short alignment mode, or 16 x 2 x in Normal I S mode / long alignment mode Compatible voltage levels (1.80 V typ.), otherwise it is recommended to connect the 1.8 V digital audio interface of the module to the external 3.0 V (or similar) digital audio device by means of appropriate UBX-13001118 - R19 Early Production Information System description Page 91 of 175 LISA-U2 series - System Integration Manual unidirectional voltage translators (e.g. Texas Instruments SN74AVC4T774 or SN74AVC2T245), using the module V_INT output as 1.8 V supply for the voltage translators on the module side For the appropriate selection of a compliant external digital audio device, see +UI2S AT command description in the u-blox AT Commands Manual [2] for further details regarding the capabilities and the possible settings of I S digital audio interface of LISA-U2 series modules. Figure 49 shows an application circuit with a generic digital audio device. LISA-U2 series 1.8 V digital audio device I2S_TXD 42 I2S Data Input I2S_RXD 44 I2S Data Output I2S_CLK 43 I2S Clock I2S_WA 41 I2S Word Alignment GND GND Figure 49: I2S interface application circuit with a generic digital audio device As in general any external digital audio device compliant to the configuration of the digital audio interface of the cellular module can be used with LISA-U2 series modules, an appropriate specific application circuit has to be implemented and configured according to the particular external digital audio device or audio codec used and according to the application requirements. Examples of manufacturers offering compatible audio codec parts, suitable to provide basic analog audio voice capability on the application device, are the following: Maxim Integrated (as the MAX9860, MAX9867, MAX9880A audio codecs) Texas Instruments / National Semiconductor Cirrus Logic / Wolfson Microelectronics Nuvoton Technology Asahi Kasei Microdevices Realtek Semiconductor Figure 50 and Table 41 describe an application circuit for I S digital audio interfaces of LISA-U2 series modules, providing voice capability using an external audio voice codec. DAC and ADC integrated in the external audio codec respectively converts an incoming digital data stream to analog audio output through a mono amplifier and converts the microphone input signal to the digital bit stream over the digital audio interface. An I S digital audio interface of the LISA-U2 series modules that acts as an I S master is connected to the digital audio interface of the external audio codec (that acts as an I S slave). The first I S interface can be used as well as the second I S interface of the cellular module. The CODEC_CLK digital output clock of the cellular module is connected to the clock input of the external audio codec to provide clock reference. Signal integrity of the high speed lines may be degraded if the PCB layout is not optimal, especially when the CODEC_CLK clock line or also the I S digital audio interface lines are very long: keep routing short and minimize parasitic capacitance to preserve signal integrity. The external audio codec is controlled by the cellular module using the DDC (I C) interface: this interface can be used to communicate with u-blox GNSS receivers and at the same time to control an external audio codec on all LISA-U2 series modules. The V_INT supply output of the cellular module provides the supply to the external audio codec, defining a proper voltage level for the digital interfaces. UBX-13001118 - R19 Early Production Information System description Page 92 of 175 LISA-U2 series - System Integration Manual Additional components are provided for EMC and ESD immunity conformity according to European Norms for R&TTE Directive (99/5/EC) and EMC Directive (89/336/EEC) compliance. The recommended parts for EMC and ESD immunity conformity are: a 10 nF bypass capacitor (e.g. Murata GRM155R71C103KA88) and a proper series chip ferrite bead noise/EMI suppression filter (e.g. Murata BLM15HD182SN1) provided on each microphone line input and speaker line output of the external codec as described in Figure 50 and Table 41. LISA-U2 series 1V8 V_INT R1 R2 R3 Audio Codec C1 C2 C3 VDD IRQn SDA 46 SDA SCL 45 SCL MICBIAS C4 MICLP MICLN I2S1_TXD 40 SDIN I2S1_RXD 39 SDOUT I2S1_CLK 53 BCLK I2S1_WA 54 LRCLK CODEC_CLK 52 EMI1 EMI2 C6 J1 R5 MICGND OUTP MCLK OUTN Microphone Connector MIC R4 C5 C12 C11 C8 C7 D1 Speaker SPK Connector EMI3 EMI4 J2 GND GND C14 C13 C10 C9 D2 U1 Figure 50: I2S interface application circuit with an external audio codec to provide voice capability Reference Description Part Number – Manufacturer C1 C2, C4, C5, C6 100 nF Capacitor Ceramic X5R 0402 10% 10V 1 µF Capacitor Ceramic X5R 0402 10% 6.3 V GRM155R71C104KA01 – Murata GRM155R60J105KE19 – Murata C3 C7, C8, C9, C10 10 µF Capacitor Ceramic X5R 0603 20% 6.3 V 27 pF Capacitor Ceramic COG 0402 5% 25 V GRM188R60J106ME47 – Murata GRM1555C1H270JZ01 – Murata C11, C12, C13, C14 D1, D2 10 nF Capacitor Ceramic X5R 0402 10% 50V Low Capacitance ESD Protection GRM155R71C103KA88 – Murata USB0002RP or USB0002DP – AVX EMI1, EMI2, EMI3, EMI4 J1 Chip Ferrite Bead Noise/EMI Suppression Filter 1800 Ohm at 100 MHz, 2700 Ohm at 1 GHz Microphone Connector BLM15HD182SN1 – Murata J2 MIC Speaker Connector 2.2 k Electret Microphone Various manufacturers Various manufacturers R1, R2 4.7 kΩ Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp R3 R4, R5 10 kΩ Resistor 0402 5% 0.1 W 2.2 kΩ Resistor 0402 5% 0.1 W RC0402JR-0710KL - Yageo Phycomp RC0402JR-072K2L – Yageo Phycomp SPK 32 Speaker 16-Bit Mono Audio Voice Codec Various manufacturers U1 Various manufacturers MAX9860ETG+ - Maxim Table 41: Example of components for audio voice codec application circuit Any external signal connected to the digital audio interface must be tri-stated or set low when the module is in power-down mode and during the module power-on sequence (at least until the activation of the V_INT supply output of the module), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the cellular module cannot be tri-stated or set low, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set it to high impedance during module power down mode and during the module power-on sequence. If the I S digital audio pins are not used, they can be left unconnected on the application board. UBX-13001118 - R19 Early Production Information System description Page 93 of 175 LISA-U2 series - System Integration Manual 1.11.4 Voiceband processing system The voiceband processing on the LISA-U2 modules is implemented in the DSP core inside the baseband chipset. The external digital audio devices can be interfaced directly to the DSP digital processing part via the I S digital interface. With exception of the speech encoder/decoder, audio processing can be controlled by AT commands. The audio processing is implemented within the different blocks of the voiceband processing system: Sample-based Voice-band Processing (single sample processed at 16 kHz for Wide Band AMR codec or 8 kHz for all other speech codecs) Frame-based Voice-band Processing (frames of 320 samples for Wide Band AMR codec or 160 samples for all other speech codecs are processed every 20 ms) These blocks are connected by buffers (circular buffer and voiceband sample buffer) and sample rate converters (for 8 / 16 to 47.6 kHz conversion). The voiceband audio processing implemented in the DSP core of LISA-U2 series modules is summarized in Figure 51. I2S_RXD Uplink Digital Gain I2Sx RX I2S1_RXD UBF 1/5 Switch UBF 2/6 Tone Generator UBF 3/7 UBF 4/8 Handsfree Sidetone Scal_Rec Digital Gain I2Sx TX I2S1_TXD Switch To Radio TX Speech level DBF 4/8 DBF 3/7 DBF 2/6 I2S_TXD DBF 1/5 From Radio RX Mix_Afe Legend: UBF= Uplink Biquad Filter DBF = Downlink Biquad Filter PCM Player Figure 51: Audio processing system of LISA-U2 series modules LISA-U2 modules audio signal processing algorithms are: Speech encoding (uplink) and decoding (downlink).The following speech codecs are supported in firmware on the DSP for speech encoding and decoding: GERAN GMSK codecs GSM HR (GSM Half Rate) GSM FR (GSM Full Rate) GSM EFR (GSM Enhanced Full Rate) HR AMR (GSM Half Rate Adaptive Multi Rate - Narrow Band) FR AMR (GSM Full Rate Adaptive Multi Rate - Narrow Band) FR AMR-WB (GSM Full Rate Adaptive Multi Rate - Wide Band) UBX-13001118 - R19 Early Production Information System description Page 94 of 175 LISA-U2 series - System Integration Manual UTRAN codecs: UMTS AMR2 (UMTS Adaptive Multi Rate version 2 – Narrow Band) UMTS AMR-WB (UMTS Adaptive Multi Rate – Wide Band) Mandatory sub-functions: Discontinuous transmission, DTX (GSM 46.031, 46.041, 46.081 and 46.093 standards) Voice activity detection, VAD (GSM 46.032, 46.042, 46.082 and 46.094 standards) Background noise calculation (GSM 46.012, 46.022, 46.062 and 46.092 standards) Function configurable via specific AT commands (see the u-blox AT Commands Manual [2]) Signal routing: +USPM command Analog amplification, Digital amplification: +USGC, +CLVL, +CRSL, +CMUT command Digital filtering: +UUBF, +UDBF commands Hands-free algorithms (echo cancellation, Noise suppression, Automatic Gain control) +UHFP command Sidetone generation (feedback of uplink speech signal to downlink path): +USTN command Playing/mixing of alert tones: Service tones: Tone generator with 3 sinus tones +UPAR command User generated tones: Tone generator with a single sinus tone +UTGN command PCM audio files (for prompting): The storage format of PCM audio files is 8 kHz sample rate, signed 16 bits, little endian, mono UBX-13001118 - R19 Early Production Information System description Page 95 of 175 LISA-U2 series - System Integration Manual 1.12 General Purpose Input/Output (GPIO) LISA-U2 series modules provide up to 14 pins (GPIO1-14) which can be configured as general purpose input or output, or can be configured to provide special functions via u-blox AT commands (for further details see the u-blox AT Commands Manual [2], +UGPIOC, +UGPIOR, +UGPIOW, +UGPS, +UGPRF, +USPM). The following functions are available in the LISA-U2 modules: GSM Tx burst indication: GPIO1 pin can be configured by AT+UGPIOC to indicate when a GSM Tx burst/slot occurs, setting the parameter of AT+UGPIOC command to 9. No GPIO pin is by default configured to provide the “GSM Tx burst indication” function. The pin configured to provide the “GSM Tx burst indication” function is set as Output / High, since ~10 µs before the start of first Tx slot, until ~5 µs after the end of last Tx slot Output / Low, otherwise The pin configured to provide the “GSM Tx burst indication” function can be connected on the application board to an input pin of an application processor to indicate when a GSM Tx burst/slot occurs. GNSS supply enable: The GPIO2 is by default configured by AT+UGPIOC command to enable or disable the supply of the u-blox GNSS receiver connected to the cellular module. The GPIO1, GPIO3, GPIO4 or GPIO5 pins can be configured to provide the “GNSS supply enable” function, alternatively to the default GPIO2 pin, setting the parameter of AT+UGPIOC command to 3. The “GNSS supply enable” mode can be provided only on one pin per time: it is not possible to simultaneously set the same mode on another pin. The pin configured to provide the “GNSS supply enable” function is set as Output / High, to switch on the u-blox GNSS receiver, if the parameter of AT+UGPS command is set to 1 Output / Low, to switch off the u-blox GNSS receiver, if the parameter of AT+UGPS command is set to 0 (default setting) The pin configured to provide the “GNSS supply enable” function must be connected to the active-high enable pin (or the active-low shutdown pin) of the voltage regulator that supplies the u-blox GNSS receiver on the application board. GNSS data ready: Only the GPIO3 pin provides the “GNSS data ready” function, to sense when a u-blox GNSS receiver connected to the cellular module is ready to send data via the DDC (I C) interface, setting the parameter of AT+UGPIOC command to 4. The pin configured to provide the “GNSS data ready” function will be set as Input, to sense the line status, waking up the cellular module from idle-mode when the u-blox GNSS receiver is ready to send data via the DDC (I C) interface; this is possible if the parameter of AT+UGPS command is set to 1 and the parameter of AT+UGPRF command is set to 16 Tri-state with an internal active pull-down enabled, otherwise (default setting) The pin that provides the “GNSS data ready” function must be connected to the data ready output of the u-blox GNSS receiver (i.e. the pin TxD1 of the u-blox GNSS receiver) on the application board. UBX-13001118 - R19 Early Production Information System description Page 96 of 175 LISA-U2 series - System Integration Manual GNSS RTC sharing: Only the GPIO4 pin provides the “GNSS RTC sharing” function, to provide an RTC (Real Time Clock) synchronization signal to the u-blox GNSS receiver connected to the cellular module, setting the parameter of AT+UGPIOC command to 5. The pin configured to provide the “GNSS RTC sharing” function will be set as Output, to provide an RTC (Real Time Clock) synchronization signal to the u-blox GNSS receiver if the parameter of AT+UGPS command is set to 1 and parameter of AT+UGPRF command is set to 32 Output / Low, otherwise (default setting) The pin that provides the “GNSS RTC sharing” function must be connected to the RTC synchronization input of the u-blox GNSS receiver (i.e. the pin EXTINT0 of the u-blox GNSS receiver) on the application board. SIM card detection: The GPIO5 pin is by default configured by AT+UGPIOC command to detect SIM card presence. Only the GPIO5 pin can be configured to provide the “SIM card detection” function, setting the parameter of AT+UGPIOC command to 7 (default setting). The pin configured to provide the “SIM card detection” function is set as Input with an internal active pull-down enabled, to sense SIM card presence The pin must be connected on the application board to SW2 pin of the SIM card holder, which must provide 2 pins for the mechanical card presence detection, with a 470 kΩ pull-down resistor. SW1 pin of the SIM card holder must be connected to V_INT pin of the module, by a 1 kΩ pull-up resistor. See Figure 52 and section 1.8 for the application circuit. The GPIO5 signal will be pulled low by the pull-down when a SIM card is not inserted in the holder, and will be pulled high by the pull-up when a SIM card is present. The GPIO5 pin is configured as an external interrupt to detect SIM card presence. An Unsolicited Result Code (URC) can be generated each time that there is a change of status (for more details see the “simind” value of the parameter of +CIND and +CMER commands in the u-blox AT Commands Manual [2]). All LISA-U2 series modules provide the additional function “SIM card hot insertion/removal” on the GPIO5 pin, which can be enabled using the AT+UDCONF=50 command (for more details see the u-blox AT Commands Manual [2]). Network status indication: GPIO1, GPIO2, GPIO3, GPIO4 or GPIO5 can be configured to indicate network status (i.e. no service, registered home 2G network, registered home 3G network, registered visitor 2G network, registered visitor 3G network, voice or data 2G/3G call enabled), setting the parameter of AT+UGPIOC command to 2. No GPIO pin is by default configured to provide the “Network status indication” function. The “Network status indication” mode can be provided only on one pin per time: it is not possible to simultaneously set the same mode on another pin. The pin configured to provide the “Network status indication” function is set as Continuous Output / Low, if no service (no network coverage or not registered) Cyclic Output / High for 100 ms, Output / Low for 2 s, if registered home 2G network Cyclic Output / High for 50 ms, Output / Low for 50 ms, Output / High for 50 ms, Output / Low for 2 s, if registered home 3G network Cyclic Output / High for 100 ms, Output / Low for 100 ms, Output / High for 100 ms, Output / Low for 2 s, if registered visitor 2G network (roaming) Cyclic Output / High for 50 ms, Output / Low for 50 ms, Output / High for 50 ms, Output / Low for 100 ms, if registered visitor 3G network (roaming) Continuous Output / High, if voice or data 2G/3G call enabled UBX-13001118 - R19 Early Production Information System description Page 97 of 175 LISA-U2 series - System Integration Manual The pin configured to provide the “Network status indication” function can be connected on the application board to an input pin of an application processor or can drive a LED by a transistor with integrated resistors to indicate network status. Module status indication: The GPIO1 and GPIO13 pins can be configured to indicate module status (power-off mode, i.e. module switched off, versus idle, active or connected mode, i.e. module switched on), properly setting the parameter of AT+UGPIOC command to 10. No GPIO pin is by default configured to provide the “Module status indication”. The pin configured to provide the “Module status indication” function is set as Output / High, when the module is switched on (any operating mode during module normal operation: idle, active or connected mode) Output / Low, when the module is switched off (power off mode) The “Module status indication” mode can be provided only on one pin at a time: it is not possible to simultaneously set the same mode on another pin. Module operating mode indication: The GPIO14 and GPIO5 pins can be configured to indicate module operating mode (idle-mode versus active or connected mode), properly setting the parameter of AT+UGPIOC command to 11. No GPIO pin is by default configured to provide the “Module operating mode indication”. The pin configured to provide the “Module operating mode indication” function is set as Output / High, when the module is in active or connected mode Output / Low, when the module is in idle-mode (that can be reached if power saving is enabled by +UPSV AT command: for further details see the u-blox AT Commands Manual [2]) The “Module operating mode indication” mode can be provided only on one pin at a time: it is not possible to simultaneously set the same mode on another pin. I S digital audio interface: The GPIO6, GPIO7, GPIO8, GPIO9 pins are by default configured as the second I S digital audio interface (I2S1_RXD, I2S1_TXD, I2S1_CLK, I2S1_WA respectively). Only these pins can be configured as the second I S digital audio interface, correctly setting the parameter of AT+UGPIOC command to 12 (default setting). SPI serial interface: GPIO10, GPIO11, GPIO12, GPIO13 and GPIO14 pins are by default configured as the SPI / IPC serial interface (SPI_SCLK, SPI_MOSI, SPI_MISO, SPI_SRDY and SPI_MRDY respectively). Only these pins can be configured as the SPI / IPC serial interface, correctly setting the parameter of AT+UGPIOC command to 13 (default setting). General purpose input: All the GPIOs can be configured as input to sense high or low digital level through AT+UGPIOR command, setting the parameter of AT+UGPIOC command to 1. The “General purpose input” mode can be provided on more than one pin at a time: it is possible to simultaneously set the same mode on another pin (also on all the GPIOs). No GPIO pin is by default configured as “General purpose input”. The pin configured to provide the “General purpose input” function is set as Input, to sense high or low digital level by AT+UGPIOR command. UBX-13001118 - R19 Early Production Information System description Page 98 of 175 LISA-U2 series - System Integration Manual The pin can be connected on the application board to an output pin of an application processor to sense the digital signal level. General purpose output: All the GPIOs can be configured as output to set the high or the low digital level through AT+UGPIOW command, setting the parameter of +UGPIOC AT command to 0. The “General purpose output” mode can be provided on more than one pin per time: it is possible to simultaneously set the same mode on another pin (also on all the GPIOs). No GPIO pin is by default configured as “General purpose output”. The pin configured to provide the “General purpose output” function is set as Output / Low, if the parameter of AT+UGPIOW command is set to 0 Output / High, if the parameter of AT+UGPIOW command is set to 1 The pin can be connected on the application board to an input pin of an application processor to provide a digital signal. Pad disabled: All the GPIOs can be configured in tri-state with an internal active pull-down enabled, as a not used pin, setting the parameter of +UGPIOC AT command to 255. The “Pad disabled” mode can be provided on more than one pin per time: it is possible to simultaneously set the same mode on another pin (also on all the GPIOs). The pin configured to provide the “Pad disabled” function is set as Tri-state with an internal active pull-down enabled Table 42 describes the configurations of all the GPIO pins. Pin Name Description Remarks 20 GPIO1 GPIO 21 GPIO2 GPIO By default, the pin is configured as Pad disabled. Can be alternatively configured by the AT+UGPIOC command as Output Input Network Status Indication GNSS Supply Enable GSM Tx Burst Indication Module Status Indication By default, the pin is configured to provide GNSS Supply Enable function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication Pad disabled 23 GPIO3 GPIO 24 GPIO4 GPIO UBX-13001118 - R19 By default, the pin is configured to provide GNSS Data Ready function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication GNSS Supply Enable Pad disabled By default, the pin is configured to provide GNSS RTC sharing function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication GNSS Supply Enable Pad disabled Early Production Information System description Page 99 of 175 LISA-U2 series - System Integration Manual Pin Name Description Remarks 51 GPIO5 GPIO 39 I2S1_RXD / GPIO6 2nd I2S receive data / GPIO 40 I2S1_TXD / GPIO7 2nd I2S transmit data / GPIO 53 I2S1_CLK / GPIO8 2nd I2S clock / GPIO 54 I2S1_WA / GPIO9 2nd I2S word alignment / GPIO 55 SPI_SCLK / GPIO10 SPI Serial Clock / GPIO 56 SPI_MOSI / GPIO11 SPI Data Line / GPIO 57 SPI_MISO / GPIO12 SPI Data Line Output / GPIO 58 SPI_SRDY / GPIO13 SPI Slave Ready / GPIO By default, the pin is configured to provide SIM card detection function. Can be alternatively configured by the +UGPIOC command as Output Input Network Status Indication GNSS Supply Enable Module Operating Mode Indication Pad disabled By default, the pin is configured as 2nd I2S receive data input. Can be alternatively configured by the +UGPIOC, +USPM commands as Output Input Pad disabled By default, the pin is configured as 2nd I2S transmit data output. Can be alternatively configured by the +UGPIOC, +USPM commands as Output Input Pad disabled By default, the pin is configured as 2nd I2S clock input/output. Can be alternatively configured by the +UGPIOC, +USPM commands as Output Input Pad disabled By default, the pin is configured as 2nd I2S word alignment input/output. Can be alternatively configured by the +UGPIOC, +USPM commands as Output Input Pad disabled By default, the pin is configured as SPI Serial Clock Input: Idle low (CPOL=0) Internal active pull-down to GND enabled Can be alternatively configured by the +UGPIOC command as Output Input Pad disabled By default, the pin is configured as SPI Data Line Input: Shift data on rising clock edge (CPHA=1) Latch data on falling clock edge (CPHA=1) Idle high Internal active pull-up to V_INT enabled Can be alternatively configured by the +UGPIOC command as Output Input Pad disabled By default, the pin is configured as SPI Data Line Output: Shift data on rising clock edge (CPHA=1) Latch data on falling clock edge (CPHA=1) Idle high Can be alternatively configured by the +UGPIOC command as Output Input Pad disabled By default, the pin is configured as SPI Slave Ready Output: Idle low Can be alternatively configured by the +UGPIOC command as Output Input Module Status Indication Pad disabled UBX-13001118 - R19 Early Production Information System description Page 100 of 175 LISA-U2 series - System Integration Manual Pin Name Description Remarks 59 SPI_MRDY / GPIO14 SPI Master Ready / GPIO By default, the pin is configured as SPI Master Ready Input: Idle low Internal active pull-down to GND enabled Can be alternatively configured by the +UGPIOC command as Output Input Module Operating Mode Indication Pad disabled Table 42: GPIO pins configurations The GPIO pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the lines are externally accessible on the application board. Higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins, close to accessible points. An application circuit for a typical GPIOs usage is described in Figure 52: Network indication function provided by the GPIO1 pin GNSS supply enable function provided by the GPIO2 pin GNSS data ready function provided by the GPIO3 pin GNSS RTC sharing function provided by the GPIO4 pin SIM card detection function provided by the GPIO5 pin Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 kΩ resistor on the board in series to the GPIO. If the GPIO pins are not used, they can be left unconnected on the application board. Any external signal connected to GPIOs must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and allow a proper boot of the module. If the external signals connected to the module cannot be tri-stated, insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157) between the two-circuit connections and set to high impedance during module power down mode, when external reset is forced low and during power-on sequence. UBX-13001118 - R19 Early Production Information System description Page 101 of 175 LISA-U2 series - System Integration Manual u-blox GNSS 1.8 V receiver LISA-U2 series LDO Regulator 3V8 IN GPIO2 21 GPS Supply Enable GPIO4 23 24 VCC SHDN C1 GND R1 GPIO3 1V8 OUT U1 GPS Data Ready TxD1 GPS RTC Sharing EXTINT0 R2 V_INT GPIO5 51 SIM card holder R3 SW1 SIM Detection SW2 J1 3V8 R4 D1 R7 DL1 GPIO1 20 R5 Network Indicator T1 R6 Figure 52: GPIO application circuit Reference Description Part Number - Manufacturer R1 U1 47 kΩ Resistor 0402 5% 0.1 W Voltage Regulator for GNSS receiver Various manufacturers See GNSS Module Hardware Integration Manual R2 4.7 kΩ Resistor 0402 5% 0.1 W Various manufacturers R3 R4 1 kΩ Resistor 0402 5% 0.1 W 470 kΩ Resistor 0402 5% 0.1 W Various manufacturers Various manufacturers D1 J1 ESD Transient Voltage Suppressor SIM Card Holder USB0002RP or USB0002DP - AVX CCM03-3013LFT R102 - C&K Components (or equivalent) R5 R6 10 kΩ Resistor 0402 5% 0.1 W 47 kΩ Resistor 0402 5% 0.1 W Various manufacturers Various manufacturers R7 DL1 820 Ω Resistor 0402 5% 0.1 W LED Red SMT 0603 Various manufacturers LTST-C190KRKT - Lite-on Technology Corporation T1 NPN BJT Transistor BC847 - Infineon Table 43: Components for GPIO application circuit UBX-13001118 - R19 Early Production Information System description Page 102 of 175 LISA-U2 series - System Integration Manual The recommended application circuit for the module status indication function, provided by LISA-U2 series module GPIO1 and GPIO13 pins to indicate module status (power-off mode, i.e. module switched off, versus idle, active or connected mode, i.e. module switched on), is described in Figure 53. The logic level of the pin configured to provide module status indication, that is set high when the module is switched on (with interfaces configured) and low when the module is switched off, is inverted by a transistor biased by the V_BCKP supply, which is generated by the module when a valid VCC is applied. A pull-down resistor is provided at the GPIO1 output (which provides module status indication) to fix a low level at inverting transistor input when GPIO1 is floating, i.e. when the module is switched off, so that high logic level is present at the application processor input when the module is switched off and low logic level when the module is switched on (i.e. the opposite logic level of the GPIO). Application processor LISA-U2 series V_BCKP R3 Input (1.8V) GPIO1 20 Module Status Indication R1 T1 R2 Figure 53: Module status indication application circuit Reference Description Part Number - Manufacturer R1, R3 R2 47 kΩ Resistor 0402 5% 0.1 W 100 kΩ Resistor 0402 5% 0.1 W Various manufacturers Various manufacturers T1 NPN BJT Transistor BC847 - Infineon Table 44: Components for module status indication application circuit 1.13 Reserved pins (RSVD) LISA-U2 modules have pins reserved for future use. All the RSVD pins, except pin number 5, can be left unconnected on the application board. Pin 5 (RSVD) must be connected to GND. UBX-13001118 - R19 Early Production Information System description Page 103 of 175 LISA-U2 series - System Integration Manual 1.14 Schematic for LISA-U2 module integration Figure 54 is an example of a schematic diagram where LISA-U2 series module is integrated into an application board, using all the interfaces of the module. LISA-U2 series 3V8 Ferrite Bead 61 VCC 62 VCC 63 VCC 330µF 100nF 10nF 15pF 68pF 68 Main Tx/Rx Antenna ANT_DIV 74 Rx Diversity Antenna LDO Regulator 3V8 V_BCKP IN 100µF GND GPIO2 21 100kΩ 19 Open Drain Output Ferrite Bead Open Drain Output 47pF 22 PWR_ON 4.7k GND 46 SDA2 45 SCL2 GPIO3 23 TxD1 GPIO4 24 EXTINT0 RESET_N V_INT 1.8V DTE Audio Codec MAX9860 TXD RTS 0Ω TP 0Ω TP 0Ω TP 15 TXD 16 RXD 13 RTS SCL 14 CTS I2S1_TXD 40 SDIN 12 DTR I2S1_RXD 39 SDOUT DSR DSR RI 10 I2S1_CLK 53 BCLK 11 DCD RI DCD GND GND MICBIAS 100nF 1µF 1µF 10µF 2.2k SDA DTR CTS V_INT VDD IRQn RXD 4.7k SCL 10k TP VCC OUT SDA 220nF 0Ω u-blox GNSS 1.8V Receiver 1V8_GPS SHDN 47k Application Processor LISA-U230 only GND RTC back-up ANT I2S1_WA 54 LRCLK CODEC_CLK 52 MCLK MICLP MICLN 1µF EMI 1µF EMI 2.2k MICGND OUTP OUTN 10nF 10nF 27pF 27pF ESD ESD SPK EMI EMI 10nF 10nF 27pF 27pF ESD ESD 1.8V SPI Master MIC 1.8V Digital Audio Device MOSI 56 SPI_MOSI MISO 57 SPI_MISO I2S_RXD 44 I2S Data Output SCLK 55 SPI_SCLK I2S_CLK 43 I2S Clock Interrupt 58 SPI_SRDY I2S_TXD 42 I2S Data Input GPIO 59 SPI_MRDY I2S_WA 41 I2S Word Alligment V_INT GPIO5 51 SW2 VSIM 50 CCVCC (C1) SIM_IO 48 CCIO (C7) SIM_CLK 47 CCCLK (C3) SIM_RST 49 CCRST (C2) GND GND SIM Card Holder V_INT USB 2.0 Host VBUS 18 VUSB_DET D+ 27 USB_D+ D- 26 USB_D- 100nF GND GND 3V8 1k SW1 CCVPP (C6) GND (C5) 470k 47pF 47pF 47pF 47pF 100nF Network Indicator 20 GPIO1 RSVD ESD ESD ESD ESD ESD ESD Figure 54: Example of schematic diagram to integrate LISA-U2 series modules in an application board, using all the interfaces UBX-13001118 - R19 Early Production Information System description Page 104 of 175 LISA-U2 series - System Integration Manual 1.15 Approvals For all the certificates of compliancy and for the complete list of approvals (including countries’ and network operators’ approvals) of LISA-U2 series modules, see our website (http://www.u-blox.com/) or contact the u-blox office or sales representative nearest you. Product certification approval is the process of certifying that a product has passed all tests and criteria required by specifications, typically called “certification schemes” that can be divided into three distinct categories: Regulatory certification Country specific approval required by local government in most regions and countries, as: Industry certification Telecom industry specific approval verifying the interoperability between devices and networks: GCF (Global Certification Forum), partnership between European device manufacturers and network operators to ensure and verify global interoperability between devices and networks CE (Conformité Européenne) marking for European Union FCC (Federal Communications Commission) approval for United States PTCRB (PCS Type Certification Review Board), created by United States network operators to ensure and verify interoperability between devices and North America networks Operator certification Operator specific approval required by some mobile network operator, as: AT&T network operator in United States Even if LISA-U2 modules are approved under all major certification schemes, the application device that integrates LISA-U2 modules must be approved under all the certification schemes required by the specific application device to be deployed in the market. The required certification scheme approvals and the related testing specifications differ depending on the country or the region where the device that integrates LISA-U2 modules must be deployed, on the corresponding vertical market of the device, on type, features and functionalities of the whole application device, and on the network operators where the device must operate. The certification of the application device that integrates a LISA-U2 module and the compliance of the application device with all the applicable certification schemes, directives and standards are the sole responsibility of the application device manufacturer. LISA-U2 modules are certified according to all capabilities and options stated in the Protocol Implementation Conformance Statement document (PICS) of the module. The PICS, according to 3GPP TS 51.010-2 [9] and 3GPP TS 34.121-2 [10], is a statement of the implemented and supported capabilities and options of a device. The PICS document of the application device integrating LISA-U2 series modules must be updated from the module PICS statement if any feature stated as supported by the module in its PICS document is not implemented or disabled in the application device. For more details regarding the AT commands settings that affect the PICS, see the u-blox AT Commands Manual [2]. Check the specific settings required for mobile network operators approvals as they may differ from the AT commands settings defined in the module as integrated in the application device. UBX-13001118 - R19 Early Production Information System description Page 105 of 175 LISA-U2 series - System Integration Manual 1.15.1 R&TTED and European Conformance CE mark Products bearing the CE marking comply with the R&TTE Directive (99/5/EC), EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms: Radio Frequency spectrum efficiency: EN 301 511 EN 301 908-1 EN 301 908-2 Electromagnetic Compatibility: EN 301 489-1 EN 301 489-7 EN 301 489-24 Safety EN 60950-1: 2006 EN 62311: 2008 Notified Body identification numbers for LISA-U2 series modules are 0682 and 1588; see the LISA-U2 series Data Sheet [1] for a complete list of the Notified Body numbers used in the certification of each module. 1.15.2 US Federal Communications Commission notice The Federal Communications Commission (FCC) IDs for the LISA-U2 modules are: LISA-U200: XPYLISAU200 LISA-U201: XPYLISAU201 LISA-U230: XPYLISAU230 LISA-U260: XPYLISAU200 LISA-U270: XPYLISAU200 1.15.2.1 Safety warnings review the structure Equipment for building-in. The requirements for fire enclosure must be evaluated in the end product The clearance and creepage current distances required by the end product must be withheld when the module is installed The cooling of the end product shall not negatively be influenced by the installation of the module Excessive sound pressure from earphones and headphones can cause hearing loss No natural rubbers, no hygroscopic materials nor materials containing asbestos are employed UBX-13001118 - R19 Early Production Information System description Page 106 of 175 LISA-U2 series - System Integration Manual 1.15.2.2 Declaration of conformity This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: this device may not cause harmful interference this device must accept any interference received, including interference that may cause undesired operation Radiofrequency radiation exposure Information: this equipment complies with FCC radiation exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the body of the user or nearby persons. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC procedures and as authorized in the module certification filing. The gain of the system antenna(s) used for LISA-U200 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.25 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band), 7.30 dBi (in 1700 MHz, i.e. AWS or UMTS FDD-4 band) and 2.74 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. The gain of the system antenna(s) used for LISA-U201 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.0 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band) and 3.5 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. The gain of the system antenna(s) used for LISA-U230 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.78 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band), 7.55 dBi (in 1700 MHz, i.e. AWS or UMTS FDD-4 band) and 3.95 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. The gain of the system antenna(s) used for LISA-U260 and LISA-U270 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.88 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band) and 4.08 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. 1.15.2.3 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by u-blox could void the user's authority to operate the equipment. Manufacturers of mobile or fixed devices incorporating the LISA-U2 modules are authorized to use the FCC Grants of the LISA-U2 modules for their own final products according to the conditions referenced in the certificates. The FCC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: LISA-U200: "Contains FCC ID: XPYLISAU200" resp. LISA-U201: "Contains FCC ID: XPYLISAU201" resp. LISA-U230: "Contains FCC ID: XPYLISAU230" resp. LISA-U260: "Contains FCC ID: XPYLISAU200" resp. LISA-U270: "Contains FCC ID: XPYLISAU200" resp. IMPORTANT: Manufacturers of portable applications incorporating the LISA-U2 modules are required to have their final product certified and apply for their own FCC Grant related to the specific portable device. This is mandatory to meet the SAR requirements for portable devices. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. UBX-13001118 - R19 Early Production Information System description Page 107 of 175 LISA-U2 series - System Integration Manual 1.15.3 Industry Canada notice The Industry Canada (IC) Certification Numbers for the LISA-U2 modules are: LISA-U200: 8595A-LISAU200N LISA-U201: 8595A-LISAU201 LISA-U230: 8595A-LISAU230N LISA-U260: 8595A-LISAU200N LISA-U270: 8595A-LISAU200N 1.15.3.1 Declaration of conformity Radiofrequency radiation exposure Information: this equipment complies with IC radiation exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and the body of the user or nearby persons. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC procedures and as authorized in the module certification filing. The gain of the system antenna(s) used for LISA-U200 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.25 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band), 7.30 dBi (in 1700 MHz, i.e. AWS or UMTS FDD-4 band) and 2.74 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. The gain of the system antenna(s) used for LISA-U201 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 0.7 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band) and 3.5 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. The gain of the system antenna(s) used for LISA-U230 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.78 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band), 7.55 dBi (in 1700 MHz, i.e. AWS or UMTS FDD-4 band) and 3.95 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. The gain of the system antenna(s) used for LISA-U260 and LISA-U270 (i.e. the combined transmission line, connector, cable losses and radiating element gain) must not exceed 4.88 dBi (in 850 MHz, i.e. GSM 850 or UMTS FDD-5 band) and 4.08 dBi (in 1900 MHz, i.e. GSM 1900 or UMTS FDD-2 band) for mobile and fixed or mobile operating configurations. 1.15.3.2 Modifications The IC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by u-blox could void the user's authority to operate the equipment. Manufacturers of mobile or fixed devices incorporating the LISA-U2 modules are authorized to use the Industry Canada Certificates of the LISA-U2 modules for their own final products according to the conditions referenced in the certificates. UBX-13001118 - R19 Early Production Information System description Page 108 of 175 LISA-U2 series - System Integration Manual The IC Label shall in the above case be visible from the outside, or the host device shall bear a second label stating: LISA-U200: "Contains IC: 8595A-LISAU200N" resp. LISA-U201: "Contains IC: 8595A-LISAU201" resp. LISA-U230: "Contains IC: 8595A-LISAU230" resp. LISA-U260: "Contains IC: 8595A-LISAU200N" resp. LISA-U270: "Contains IC: 8595A-LISAU200N" resp. Canada, Industry Canada (IC) Notices This Class B digital apparatus complies with Canadian CAN ICES-3(B) / NMB-3(B) and RSS-210. Operation is subject to the following two conditions: this device may not cause interference this device must accept any interference, including interference that may cause undesired operation of the device Radio Frequency (RF) Exposure Information The radiated output power of the u-blox Cellular Module is below the Industry Canada (IC) radio frequency exposure limits. The u-blox Cellular Module should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions (antennas are greater than 20cm from a person's body). This device has been certified for use in Canada. Status of the listing in the Industry Canada’s REL (Radio Equipment List) can be found at the following web address: http://www.ic.gc.ca/app/sitt/reltel/srch/nwRdSrch.do?lang=eng Additional Canadian information on RF exposure also can be found at the following web address: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html IMPORTANT: Manufacturers of portable applications incorporating the LISA-U2 modules are required to have their final product certified and apply for their own Industry Canada Certificate related to the specific portable device. This is mandatory to meet the SAR requirements for portable devices. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Canada, avis d'Industrie Canada (IC) Cet appareil numérique de classe B est conforme aux normes canadiennes CAN ICES-3(B) / NMB3(B) et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes: cet appareil ne doit pas causer d'interférence cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement Informations concernant l'exposition aux fréquences radio (RF) La puissance de sortie émise par l’appareil de sans fil u-blox Cellular Module est inférieure à la limite d'exposition aux fréquences radio d'Industrie Canada (IC). Utilisez l’appareil de sans fil u-blox Cellular Module de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a été évalué et démontré conforme aux limites d'exposition aux fréquences radio (RF) d'IC lorsqu'il est installé dans des produits hôtes particuliers qui fonctionnent dans des conditions d'exposition à des appareils mobiles (les antennes se situent à plus de 20 centimètres du corps d'une personne). UBX-13001118 - R19 Early Production Information System description Page 109 of 175 LISA-U2 series - System Integration Manual Ce périphérique est homologué pour l'utilisation au Canada. Pour consulter l'entrée correspondant à l’appareil dans la liste d'équipement radio (REL - Radio Equipment List) d'Industrie Canada rendez-vous sur: http://www.ic.gc.ca/app/sitt/reltel/srch/nwRdSrch.do?lang=fra Pour des informations supplémentaires concernant l'exposition aux RF au Canada rendez-vous sur : http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf08792.html IMPORTANT: les fabricants d'applications portables contenant les modules LISA-U2 series doivent faire certifier leur produit final et déposer directement leur candidature pour un certificat Industrie Canada délivré par l'organisme chargé de ce type d'appareil portable. Ceci est obligatoire afin d'être en accord avec les exigences SAR pour les appareils portables. Tout changement ou modification non expressément approuvé par la partie responsable de la certification peut annuler le droit d'utiliser l'équipement. 1.15.4 ACMA Certification LISA-U200 and LISA-U230 modules are certified by the Australian Communications and Media Authority The ACMA recommends that telephones be able to support access to emergency numbers (such as 000) for at least 30 minutes during a power failure. For telephones that do not function during a power failure, the technical standard suggests that a warning notice be included in the instructions, advising users that the phone will not operate if there is a power failure. It is the customer's responsibility to determine if their product is subject to such recommendations and apply the warning notice requirement as appropriate. 1.15.5 ICASA Certification LISA-U200 and LISA-U270 modules are certified by the Independent Communications Authority of South Africa (ICASA). UBX-13001118 - R19 Early Production Information System description Page 110 of 175 LISA-U2 series - System Integration Manual 1.15.6 KCC Certification LISA-U200 and LISA-U270 modules are certified by the Korea Communications Commission (KCC). KCC ID for LISA-U2 modules: LISA-U200: KCC-CRM-ULX-LISA-U200 LISA-U270: KCC-CRM-ULX-LISA-U270 1.15.7 Anatel Certification LISA-U200 modules are certified by the Brazilian Agency of Telecommunications (Agência Nacional de Telecomunicações in Portuguese) (Anatel). LISA-U200 3309-12-8459 (01)0 789 8941 57508 3 Anatel IDs for LISA-U200 modules: EAN barcode: (01)0 789 8941 57508 3 Homologation number 3309-12-8459 UBX-13001118 - R19 Early Production Information System description Page 111 of 175 LISA-U2 series - System Integration Manual 1.15.8 CCC Certification LISA-U200 and LISA-U230 modules are CCC certified 1.15.9 TELEC / JATE Certification LISA-U200-62S, LISA-U270-62S and LISA-U270-68S are TELEC / JATE certified and have the Giteki mark placed on the product label. LISA-U200-62S: Technical Conditions certified type number = AD120274003 Technical Requirements certified type number = 003-120375 LISA-U270-62S and LISA-U270-68S: Technical Conditions certified type number = AD120274003 Technical Requirements certified type number = 003-120377 xxS-xx LISA-U200 AD120274003 003-120375 0682 xxS-xx LISA-U270 AD120274003 003-120377 UBX-13001118 - R19 0682 Early Production Information System description Page 112 of 175 LISA-U2 series - System Integration Manual 2 Design-In 2.1 Design-in checklist This section provides a design-in checklist. 2.1.1 Schematic checklist The following are the most important points for a simple schematic check: DC supply must provide a nominal voltage at VCC pin above the minimum operating range limit. VCC supply should be clean, with very low ripple/noise: provide the suggested series ferrite bead and bypass capacitors, in particular if the application device integrates an internal antenna. VCC voltage must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module. Provide appropriate access to USB interface and/or to UART RxD, TxD, CTS, RTS lines for debugging. Connect the pin number 5 (RSVD) to ground. All unused pins can be left floating on the application board except the PWR_ON pin (must be connected to V_BCKP by a pull-up resistor) and the RSVD pin number 5 (must be connected to GND). DC supply must be capable of providing 2.5 A current pulses, providing a voltage at VCC pin above the minimum operating range limit and with a maximum 400 mV voltage drop from the nominal value. Do not leave PWR_ON floating: add a pull-up resistor to V_BCKP. Do not apply loads which might exceed the limit for maximum available current from V_INT supply. Check that voltage level of any connected pin does not exceed the specific operating range. Capacitance and series resistance must be limited on each SIM signal to match the SIM specifications. Insert the suggested low capacitance ESD protection and passive filtering parts on each SIM signal. Check UART signals direction, since the signal names follow the ITU-T V.24 Recommendation [3]. Provide appropriate access to USB interface and/or to UART RxD, TxD lines and access to PWR_ON and/or RESET_N lines to flash/upgrade the module firmware using the u-blox EasyFlash tool. Capacitance and series resistance must be limited on each line of the SPI / IPC interface. Add a proper pull-up resistor to a proper supply on each DDC (I C) interface line, if the interface is used. Capacitance and series resistance must be limited on each line of the DDC interface. Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 kΩ resistor on the board in series to the GPIO when those are used to drive LEDs. Check the digital audio interface specifications to connect a proper device. Capacitance and series resistance must be limited on CODEC_CLK line and each I S interface line. Provide proper precautions for ESD immunity as required on the application board. Any external signal connected to the UART interface, SPI/IPC interface, I S interfaces and GPIOs must be tri-stated when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and let a proper boot of the module. UBX-13001118 - R19 Early Production Information Design-In Page 113 of 175 LISA-U2 series - System Integration Manual 2.1.2 Layout checklist The following are the most important points for a simple layout check: Check 50 nominal characteristic impedance of the RF transmission line connected to the ANT pad (main RF input/output) and to the ANT_DIV pad (RF input for Rx diversity). Follow the recommendations of the antenna producer for correct antenna installation and deployment (PCB layout and matching circuitry). Ensure no coupling occurs with other noisy or sensitive signals (e.g. SIM signals). Route VCC supply line away from sensitive analog signals. Ensure proper grounding. VCC line should be as wide and as short as possible. Provide the suggested series ferrite bead and bypass capacitors close to the VCC pins implementing the recommended layout and placement, especially if the application device integrates an internal antenna. The high-power audio outputs lines on the application board must be wide enough to minimize series resistance. Consider “No-routing” areas for the Data Module footprint. Optimize placement for minimum length of RF line and closer path from DC source for VCC. Design USB_D+ / USB_D- connection as 90 differential pair, with 30 common mode impedance. Keep routing short and minimize parasitic capacitance on the SPI lines to preserve signal integrity. Keep routing short and minimize parasitic capacitance on CODEC_CLK line to preserve signal integrity. 2.1.3 Antenna checklist Antenna should have 50 impedance, V.S.W.R less than 3:1 (recommended 2:1) on operating bands in deployment geographical area. Follow the recommendations of the antenna producer for correct antenna installation and deployment (PCB layout and matching circuitry). Follow the additional guidelines for products marked with the FCC logo (United States only) reported in section 1.15.2.2 The antenna connected to the ANT pad should have built in DC resistor to ground to get proper antenna detection functionality. The antenna for the Rx diversity connected to the ANT_DIV pin should be carefully separated from the main Tx/Rx antenna connected to the ANT pin: the distance between the two antennas should be at least greater than half a wavelength of the lowest used frequency (i.e. distance greater than ~20 cm, for 2G/3G low bands) to distinguish between different multipath channels, for proper spatial diversity implementation. UBX-13001118 - R19 Early Production Information Design-In Page 114 of 175 LISA-U2 series - System Integration Manual 2.2 Design Guidelines for Layout The following design guidelines must be met for optimal integration of LISA-U2 modules on the final application board. 2.2.1 Layout guidelines per pin function LISA-U2 series (Top View) 28 29 30 31 32 33 34 35 36 37 38 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Legend: Very Important Careful Layout Common Practice 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 GND GND VCC VCC VCC GND SPI_MRDY / GPIO14 SPI_SRDY / GPIO13 SPI_MISO / GPIO12 SPI_MOSI / GPIO11 SPI_SCLK / GPIO10 GPIO9 / I2S1_WA GPIO8 / I2S1_CLK RSVD / CODEC_CLK GPIO5 VSIM SIM_RST SIM_IO SIM_CLK SDA SCL RSVD / I2S_RXD RSVD / I2S_CLK RSVD / I2S_TXD RSVD / I2S_WA GPIO7 / I2S1_TXD GPIO6 / I2S1_RXD GND GND GND GND GND GND GND GND GND GND GND GND V_BCKP GND V_INT RSVD GND GND GND DSR RI DCD DTR RTS CTS TXD RXD GND VUSB_DET PWR_ON GPIO1 GPIO2 RESET_N GPIO3 GPIO4 GND USB_DUSB_D+ 76 75 74 73 72 71 70 69 68 67 66 GND GND ANT_DIV / RSVD GND GND GND GND GND ANT GND GND This section groups LISA-U2 modules pins by signal function and provides a ranking of importance in layout design. Figure 55: LISA-U2 series modules pin-out (top view) with ranked importance for layout design UBX-13001118 - R19 Early Production Information Design-In Page 115 of 175 LISA-U2 series - System Integration Manual Rank Layout Remarks ANT Very Important RF input for Rx diversity ANT_DIV Very Important Main DC Supply VCC Very Important 3rd USB Signals USB_D+ USB_D- Very Important 4th Ground Design for 50 characteristic impedance. See section 2.2.1.1 Design for 50 characteristic impedance. See section 2.2.1.1 VCC line should be wide and short. Route away from sensitive analog signals. See section 2.2.1.2 Route USB_D+ and USB_D- as differential lines: design for 90 differential impedance (Z0) and design for 30 common mode impedance (ZCM). See section 2.2.1.3 Provide proper grounding. See section 2.2.1.4 1st nd th 6th 7th Function RF Antenna Main RF input/output Pin(s) GND Careful Layout Sensitive Pin: Backup Voltage V_BCKP Power-On High-speed digital pins: SPI Signals PWR_ON Clock Output Digital pins and supplies: SIM Card Interface Digital Audio DDC UART Avoid coupling with noisy signals. See section 2.2.1.5 Careful Layout Avoid coupling with sensitive signals. See section 2.2.1.6 Common Practice Follow common practice rules for digital pin routing. See section 2.2.1.7 SPI_SCLK, SPI_MISO, SPI_MOSI, SPI_SRDY, SPI_MRDY CODEC_CLK VSIM, SIM_CLK, SIM_IO, SIM_RST I2S_CLK, I2S_RXD, I2S_TXD, I2S_WA I2S1_CLK, I2S1_RXD, I2S1_TXD, I2S1_WA SCL, SDA USB detection TXD, RXD, CTS, RTS, DSR, RI, DCD, DTR RESET_N GPIO1, GPIO2, GPIO3, GPIO4, GPIO5 GPIO6, GPIO7, GPIO8, GPIO9, GPIO10, GPIO11, GPIO12, GPIO13, GPIO14 VUSB_DET Supply for Interfaces V_INT External Reset General Purpose I/O Careful Layout Table 45: Pin list in order of decreasing importance for layout design UBX-13001118 - R19 Early Production Information Design-In Page 116 of 175 LISA-U2 series - System Integration Manual 2.2.1.1 RF antenna connection The ANT pin (main RF input/output) and the ANT_DIV pin (RF input for diversity receiver provided by LISA-U230 modules) are very critical in layout design. Proper transition between ANT and ANT_DIV pads and the application board must be provided, implementing the following design-in guidelines for the layout of the application PCB close to the ANT and ANT_DIV pads: On a multi layer board, the whole layer stack below the RF connection should be free of digital lines Increase GND keep-out (i.e. clearance) for ANT and ANT_DIV pads to at least 250 µm up to adjacent pads metal definition and up to 500 µm on the area below the module, as described in Figure 56 Add GND keep-out (i.e. clearance) on buried metal layers below ANT and ANT_DIV pads and below any other pad of component present on the RF line, if top-layer to buried layer dielectric thickness is below 200 µm, to reduce parasitic capacitance to ground (see Figure 56 for the description of the GND keep-out area below ANT and ANT_DIV pads) Top layer Buried metal layer Min. 250 um Microstrip 50 ohm Min. 500 um GND plane Figure 56: GND keep-out area on top layer around ANT and ANT_DIV pads and on buried layer below ANT and ANT_DIV pads The transmission line from the ANT pad and the ANT_DIV pad up to antenna connector(s) or up to the internal antenna(s) pad must be designed so that the characteristic impedance is as close as possible to 50 . The transmission line up to antenna connector or pad may be a microstrip (consists of a conducting strip separated from a ground plane by a dielectric material) or a strip line (consists of a flat strip of metal which is sandwiched between two parallel ground planes within a dielectric material). In any case must be designed to achieve 50 Ω characteristic impedance Microstrip lines are usually easier to implement and the reduced number of layer transitions up to antenna connector simplifies the design and diminishes reflection losses. However, the electromagnetic field extends to the free air interface above the stripline and may interact with other circuitry Buried striplines exhibit better shielding to external and internally generated interferences. They are therefore preferred for sensitive application. In case a stripline is implemented, carefully check that the via pad-stack does not couple with other signals on the crossed and adjacent layers Figure 57 and Figure 58 provide two examples of proper 50 coplanar waveguide designs. The first transmission line can be implemented in case of 4-layer PCB stack-up herein described, the second transmission line can be implemented in case of 2-layer PCB stack-up herein described. UBX-13001118 - R19 Early Production Information Design-In Page 117 of 175 LISA-U2 series - System Integration Manual 500 µm 380 µm 500 µm L1 Copper 35 µm FR-4 dielectric 270 µm L2 Copper 35 µm FR-4 dielectric 760 µm L3 Copper 35 µm FR-4 dielectric 270 µm L4 Copper 35 µm Figure 57: Example of 50 coplanar waveguide transmission line design for the described 4-layer board layup 400 µm 1200 µm 400 µm L1 Copper 35 µm FR-4 dielectric 1510 µm L2 Copper 35 µm Figure 58: Example of 50 coplanar waveguide transmission line design for the described 2-layer board layup If the two examples do not match the application PCB layup, the 50 characteristic impedance calculation can be made using the HFSS commercial finite element method solver for electromagnetic structures from Ansys Corporation, or using freeware tools like AppCAD from Agilent or TXLine from Applied Wave Research, taking care of the approximation formulas used by the tools for the impedance computation. To achieve a 50 characteristic impedance, the width of the transmission line must be chosen depending on: the thickness of the transmission line itself (e.g. 35 µm in the example of Figure 57 and Figure 58) the thickness of the dielectric material between the top layer (where the transmission line is routed) and the inner closer layer implementing the ground plane (e.g. 270 µm in Figure 57, 1510 µm in Figure 58) the dielectric constant of the dielectric material (e.g. dielectric constant of the FR-4 dielectric material in Figure 57 and Figure 58) the gap from the transmission line to the adjacent ground plane on the same layer of the transmission line (e.g. 500 µm in Figure 57, 400 µm in Figure 58) If the distance between the transmission line and the adjacent GND area (on the same layer) does not exceed 5 times the track width of the microstrip, use the “Coplanar Waveguide” model for the 50 calculation. Additionally to the 50 impedance, the following guidelines are recommended for the RF line design: Minimize the transmission line length; the insertion loss should be minimized as much as possible, in the order of a few tenths of a dB UBX-13001118 - R19 Early Production Information Design-In Page 118 of 175 LISA-U2 series - System Integration Manual The transmission line should not have abrupt change to thickness and spacing to GND, but must be uniform and routed as smoothly as possible The transmission line must be routed in a section of the PCB where minimal interference from noise sources can be expected Route RF transmission line far from other sensitive circuits as it is a source of electromagnetic interference Ensure solid metal connection of the adjacent metal layer on the PCB stack-up to main ground layer Add GND vias around transmission line Ensure no other signals are routed parallel to transmission line, or that other signals cross on adjacent metal layer If the distance between the transmission line and the adjacent GND area (on the same layer) does not exceed 5 times the track width of the microstrip, use the “Coplanar Waveguide” model for 50 Ω characteristic impedance calculation Do not route microstrip line below discrete component or other mechanics placed on top layer When terminating transmission line on antenna connector (or antenna pad) it is very important to strictly follow the connector manufacturer’s recommended layout GND layer under RF connectors and close to buried vias should be cut out in order to remove stray capacitance and thus keep the RF line 50 Ω. In most cases the large active pad of the integrated antenna or antenna connector needs to have a GND keep-out (i.e. clearance) at least on first inner layer to reduce parasitic capacitance to ground. Note that the layout recommendation is not always available from connector manufacturer: e.g. the classical SMA Pin-Through-Hole needs to have GND cleared on all the layers around the central pin up to annular pads of the four GND posts. Check 50 Ω impedance of ANT and ANT_DIV lines Ensure no coupling occurs with other noisy or sensitive signals The antenna for the Rx diversity should be carefully separated from the main Tx/Rx antenna to ensure that uncorrelated signals are received at each antenna, because signal improvement is dependent on the cross correlation and the signal strength levels between the two received signals. The distance between the two antennas should be greater than half a wavelength of the lowest used frequency (i.e. distance greater than ~20 cm, for 2G/3G low bands) to distinguish between different multipath channels, for proper spatial diversity implementation Any RF transmission line on PCB should be designed for 50 Ω characteristic impedance. Ensure no coupling occurs with other noisy or sensitive signals. UBX-13001118 - R19 Early Production Information Design-In Page 119 of 175 LISA-U2 series - System Integration Manual 2.2.1.2 Main DC supply connection The DC supply of LISA-U2 modules is very important for the overall performance and functionality of the integrated product. For detailed description, check the design guidelines in section 1.5.2. Some main characteristics are: VCC pins are internally connected, but it is recommended to use all the available pins in order to minimize the power loss due to series resistance VCC connection may carry a maximum burst current in the order of 2.5 A. Therefore, it is typically implemented as a wide PCB line with short routing from DC supply (DC-DC regulator, battery pack, etc) The module automatically initiates an emergency shutdown if supply voltage drops below hardware threshold. In addition, reduced supply voltage can set a worst case operation point for RF circuitry that may behave incorrectly. It follows that each voltage drop in the DC supply track will restrict the operating margin at the main DC source output. Therefore, the PCB connection must exhibit a minimum or zero voltage drop. Avoid any series component with Equivalent Series Resistance (ESR) greater than a few milliohms Given the large burst current, VCC line is a source of disturbance for other signals. Therefore route VCC through a PCB area separated from sensitive analog signals. Typically it is good practice to interpose at least one layer of PCB ground between VCC track and other signal routing The VCC supply current supply flows back to main DC source through GND as ground current: provide adequate return path with suitable uninterrupted ground plane to main DC source A tank bypass capacitor with low ESR is recommended to smooth current spikes. This is most effective when placed close to the VCC pins. If the main DC source is a switching DC-DC converter, place the large capacitor close to the DC-DC output and minimize the VCC track length. Otherwise consider using separate capacitors for DC-DC converter and LISA-U2 module tank capacitor. Note that the capacitor voltage rating may be adequate to withstand the charger over-voltage if battery-pack is used. The use of very large capacitors (i.e. greater then 1000 µF) must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch on of the module VCC is directly connected to the RF power amplifiers. It is highly recommended to place a series ferrite bead for GHz band noise, a bypass capacitor with Self-Resonant Frequency in 800/900 MHz range and a bypass capacitor with self-resonant frequency in 1800/1900 MHz range as close as possible to the VCC pins, especially if the application device integrates an internal antenna. This is described in Figure 9 and Table 10. Since VCC is directly connected to RF Power Amplifiers, voltage ripple at high frequency may result in unwanted spurious modulation of transmitter RF signal. This is more likely to happen with switching DC-DC converters, in which case it is better to select the highest operating frequency for the switcher and add a large L-C filter before connecting to the LISA-U2 modules in the worst case The large current generates a magnetic field that is not well isolated by PCB ground layers and which may interact with other analog modules (e.g. VCO) even if placed on opposite side of PCB. In this case route VCC away from other sensitive functional units The typical GSM burst has a periodic nature of approx. 217 Hz, which lies in the audible audio range. Avoid coupling between VCC and audio lines (especially microphone inputs) If VCC is protected by transient voltage suppressor / reverse polarity protection diode to ensure that the voltage maximum ratings are not exceeded, place the protecting device along the path from the DC source toward the LISA-U2 module, preferably closer to the DC source (otherwise functionality may be compromised) VCC line should be as wide and as short as possible. Route away from sensitive analog signals. UBX-13001118 - R19 Early Production Information Design-In Page 120 of 175 LISA-U2 series - System Integration Manual 2.2.1.3 USB signal The LISA-U2 modules include a high-speed USB 2.0 compliant interface with a maximum throughput of 480 Mb/s (see Section 1.9.3). Signals USB_D+ / USB_D- carry the USB serial data and signaling. The lines are used in single ended mode for relatively low speed signaling handshake, as well as in differential mode for fast signaling and data transfer. Characteristic impedance of USB_D+ / USB_D- lines is specified by USB standard. The most important parameter is the differential characteristic impedance applicable for odd-mode electromagnetic field, which should be as close as possible to 90 differential: signal integrity may be degraded if PCB layout is not optimal, especially when the USB signaling lines are very long. Route USB_D+ / USB_D- lines as a differential pair Ensure the differential characteristic impedance (Z0) is as close as possible to 90 Ensure the common mode characteristic impedance (ZCM) is as close as possible to 30 Consider design rules for USB_D+ / USB_D- similar to RF transmission lines, being them coupled differential micro-strip or buried stripline: avoid any stubs, abrupt change of layout, and route on clear PCB area Figure 59 and Figure 60 provide two examples of coplanar waveguide designs with differential characteristic impedance close to 90 and common mode characteristic impedance close to 30 . The first transmission line can be implemented in case of 4-layer PCB stack-up herein described, the second transmission line can be implemented in case of 2-layer PCB stack-up herein described. 400 µm 350 µm 400 µm 350 µm 400 µm L1 Copper 35 µm FR-4 dielectric 270 µm L2 Copper 35 µm FR-4 dielectric 760 µm L3 Copper 35 µm FR-4 dielectric 270 µm L4 Copper 35 µm Figure 59: Example of USB line design, with Z0 close to 90 and ZCM close to 30 , for the described 4-layer board layup 410 µm 740 µm 410 µm 740 µm 410 µm L1 Copper 35 µm FR-4 dielectric 1510 µm L2 Copper 35 µm Figure 60: Example of USB line design, with Z0 close to 90 and ZCM close to 30 , for the described 2-layer board layup UBX-13001118 - R19 Early Production Information Design-In Page 121 of 175 LISA-U2 series - System Integration Manual 2.2.1.4 Module grounding Good connection of the module with application board solid ground layer is required for correct RF performance. It significantly reduces EMC issues and provides a thermal heat sink for the module. Connect each GND pin with application board solid GND layer. It is strongly recommended that each GND pad surrounding VCC pins have one or more dedicated via down to the application board solid ground layer If the application board is a multilayer PCB, then it is required to connect together each GND area with complete via stack down to main board ground layer It is recommended to implement one layer of the application board as ground plane Good grounding of GND pads will also ensure thermal heat sink. This is critical during call connection, when the real network commands the module to transmit at maximum power: proper grounding helps prevent module overheating 2.2.1.5 Other sensitive pins A few other pins on the LISA-U2 modules requires careful layout. RTC supply (V_BCKP): avoid injecting noise on this voltage domain as it may affect RTC oscillator stability Power-On (PWR_ON): is the digital input to switch-on the LISA-U2 modules. Ensure that the voltage level is well defined during operation and no transient noise is coupled on this line, otherwise the module might detect a spurious power-on request 2.2.1.6 High-speed digital pins The following high speed digital pins require careful layout: Serial Peripheral Interface (SPI): can be used for high speed data transfer (UMTS/HSPA) between the LISA-U2 modules and the host processor, with a data rate up to 26 Mb/s (see Section 1.9.3). The high-speed data rate is carried by signals SPI_SCLK, SPI_MISO and SPI_MOSI, while SPI_SRDY and SPI_MRDY behave as handshake signals with relatively low activity Digital Clock Output (CODEC_CLK): can be used to provide a 26 MHz or 13 MHz digital clock to an external audio codec Follow these hints for high speed digital pins layout: High-speed signals become sources of digital noise, route away from RF and other sensitive analog signals Keep routing short and minimize parasitic capacitance to preserve digital signal integrity It is recommended to match the length of SPI signals 2.2.1.7 Digital pins and supplies External Reset (RESET_N): input for external reset, a logic low voltage will reset the module SIM Card Interface (VSIM, SIM_CLK, SIM_IO, SIM_RST): the SIM layout may be critical if the SIM card is placed far away from the LISA-U2 modules or in close proximity to the RF antenna. In the first case the long connection can cause the radiation of some harmonics of the digital data frequency. In the second case the same harmonics can be picked up and create self-interference that can reduce the sensitivity of GSM Receiver channels whose carrier frequency is coincidental with harmonic frequencies. The latter case, placing the RF bypass capacitors, suggested in the section 1.8, near the SIM connector will mitigate the problem. In addition, since the SIM card is typically accessed by the end user, it can be subjected to ESD discharges: add adequate ESD protection to protect module SIM pins near the SIM connector Digital Audio (I2S_CLK, I2S_RX, I2S_TX, I2S_WA and I2S1_CLK, I2S1_RXD, I2S1_TXD, I2S1_WA): the I S interface requires the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs UBX-13001118 - R19 Early Production Information Design-In Page 122 of 175 LISA-U2 series - System Integration Manual DDC (SCL, SDA): the DDC interface requires the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs UART (TXD, RXD, CTS, RTS, DSR, RI, DCD, DTR): the serial interface requires the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs General Purpose I/O (GPIOx): the general purpose input/output pins are generally not critical for layout Reserved pins: these pins are reserved for future use. Leave them unconnected on the baseboard USB detection (VUSB_DET): this input will generate an interrupt to the baseband processor for USB detection. The USB supply (5.0 V typ.) must be provided to VUSB_DET by the connected USB host to enable the USB interface of the module Interfaces Supply (V_INT): this supply output is generated by an integrated switching step down converter, used internally to supply the digital interfaces. Because of this, it can be a source of noise: avoid coupling with sensitive signals UBX-13001118 - R19 Early Production Information Design-In Page 123 of 175 LISA-U2 series - System Integration Manual 2.2.2 Footprint and paste mask The following figure describes the footprint and provides recommendations for the paste mask for LISA-U2 modules. These are recommendations only and not specifications. Note that the copper and solder masks have the same size and position. 5.7 mm [224.4 mil] 0.9 mm [35.4 mil] 22.4 mm [881.9 mil] 2.3 mm [90.6 mil] 0.8 mm [31.5 mil] 0.6 mm [23.6 mil] 33.2 mm [1307.1 mil] 1.1 mm [43.3 mil] 2.3 mm [90.6 mil] 0.8 mm [31.5 mil] 33.2 mm [1307.1 mil] Stencil: 150 µm 1.1 mm [43.3 mil] 1.2 mm [47.2 mil] 1.0 mm [39.3 mil] 0.8 mm [31.5 mil] 5.7 mm [224.4 mil] 22.4 mm [881.9 mil] Figure 61: LISA-U2 modules suggested footprint and paste mask To improve the wetting of the half vias, reduce the amount of solder paste under the module and increase the volume outside of the module by defining the dimensions of the paste mask to form a T-shape (or equivalent) extending beyond the copper mask. The solder paste should have a total thickness of 150 µm. The paste mask outline needs to be considered when defining the minimal distance to the next component. The exact geometry, distances, stencil thicknesses and solder paste volumes must be adapted to the specific production processes (e.g. soldering etc.) of the customer. The implemetation of a step stencil (a stencil with different material thicknesses) should be considered if very different sized components must be soldered on the same application PCB: while high density chip housings with small pitch need small solder paste quantities for the avoidance of short-circuits and therefore require thin stencils, large components need more solder paste for a safe connection and thus thicker stencils. The bottom layer of LISA-U2 series modules has two unprotected copper areas for GND, shown in Figure 62. Consider “No-routing” areas for the LISA-U2 modules footprint as follows: signal keep-out area on the top layer of the application board, below LISA-U2 modules, due to GND opening on module bottom layer (see Figure 62). UBX-13001118 - R19 Early Production Information Design-In Page 124 of 175 LISA-U2 series - System Integration Manual 1.3 mm 5.25 mm 5.3 mm 5.3 mm 5.25 mm 1.4 mm 1.0 mm PIN 1 Exposed GND on LISA-U module bottom layer Signals keep-out areas on application board 33.2 mm LISA-U2 bottom side (through module view) 22.4 mm Figure 62: Signals keep-out areas on the top layer of the application board, below LISA-U2 series modules 2.2.3 Placement Optimize placement for minimum length of RF line and closer path from DC source for VCC. Make sure that RF and analog circuits are clearly separated from any other digital circuits on the system board. Provide enough clearance between the module and any external part due to solder and paste masks design. Milled edges that are present at module PCB corners, away from module pins metallization, can slightly increase module dimensions from the width and the height described in the mechanical specifications sections of LISA-U2 series Data Sheet [1]: provide enough clearance between module PCB corners and any other external part mounted on the application board. The heat dissipation during continuous transmission at maximum power can significantly raise the temperature of the application base-board below the LISA-U2 modules: avoid placing temperature sensitive devices (e.g. GNSS receiver) close to the module. UBX-13001118 - R19 Early Production Information Design-In Page 125 of 175 LISA-U2 series - System Integration Manual 2.3 Thermal guidelines LISA-U2 module operating temperature range and module thermal resistance are specified in the LISA-U2 series Data Sheet [1]. The most critical condition concerning module thermal performance is the uplink transmission at maximum power (data upload or voice call in connected mode), when the baseband processor runs at full speed, radio circuits are all active and the RF power amplifier is driven to higher output RF power. This scenario is not often encountered in real networks; however the application should be correctly designed to cope with it. During transmission at maximum RF power the LISA-U2 modules generate thermal power that can exceed 2 W: this is an indicative value since the exact generated power strictly depends on operating condition such as the number of allocated TX slot and modulation (GMSK or 8PSK) or data rate (WCDMA), transmitting frequency band, etc. The generated thermal power must be adequately dissipated through the thermal and mechanical design of the application. The spreading of the Module-to-Ambient thermal resistance (Rth,M-A) depends on the module operating condition (e.g. 2G or 3G mode, transmit band): the overall temperature distribution is influenced by the configuration of the active components during the specific mode of operation and their different thermal resistance toward the case interface. Mounting a LISA-U2 module on a 90 mm x 70 mm x 1.46 mm 4-Layers PCB with a high coverage of copper in still air conditions , the increase of the module temperature in different modes of operation, referred to idle state initial condition , can be summarized as following: 7°C during a GSM voice call at max TX power 19°C during GPRS data transfer with 4 TX slots at max TX power 16°C during EDGE data transfer with 4 TX slots at max TX power 25°C in UMTS/HSxPA connection at max TX power The Module-to-Ambient thermal resistance value and the related increase of module temperature will be different for other mechanical deployments of the module, e.g. PCB with different dimensions and characteristics, mechanical shells enclosure, or forced air flow. The increase of thermal dissipation, i.e. the Module-to-Ambient thermal resistance reduction, will decrease the temperature for internal circuitry of LISA-U2 modules for a given operating ambient temperature. This improves the device long-term reliability for applications operating at high ambient temperature. Recommended hardware techniques to be used to improve heat dissipation in the application: Connect each GND pin with solid ground layer of the application board and connect each ground area of the multilayer application board with complete via stack down to main ground layer Provide a ground plane as wide as possible on the application board Optimize antenna return loss, to optimize overall electrical performance of the module including a decrease of module thermal power Optimize the thermal design of any high-power component included in the application, as linear regulators and amplifiers, to optimize overall temperature distribution in the application device Select the material, the thickness and the surface of the box (i.e. the mechanical enclosure of the application device that integrates the module) so that it provides good thermal dissipation Refer to LISA-U2 series Data Sheet [1] for the Rth,M-A value in this application condition Temperature is measured by internal sensor of wireless module Steady state thermal equilibrium is assumed. The module’s temperature in idle state can be considered equal to ambient temperature UBX-13001118 - R19 Early Production Information Design-In Page 126 of 175 LISA-U2 series - System Integration Manual Further hardware techniques to be used to improve heat dissipation in the application: Force ventilation air-flow within mechanical enclosure Provide a heat sink component attached to the module top side, with electrically insulated / high thermal conductivity adhesive, or on the backside of the application board, below the cellular module, as a large part of the heat is transported through the GND pads and dissipated over the backside of the application board For example, after the installation of a robust aluminum heat-sink with forced air ventilation on the back of the same application board described above, the Module-to-Ambient thermal resistance (Rth,M-A) is reduced to 1.5 ÷ 3.5 °C/W. The effect of lower Rth,M-A can be seen from the module temperature increase, which now can be summarized as following: 1.5°C during a GSM voice call at max TX power 3°C during GPRS data transfer with 4 TX slots at max TX power 2.5°C during EDGE data transfer with 4 TX slots at max TX power 5.5°C in UMTS/HSxPA connection at max TX power Beside the reduction of the Module-to-Ambient thermal resistance implemented by the hardware design of the application device integrating a LISA-U2 module, the increase of module temperature can be moderated by the software implementation of the application. Since the most critical condition concerning module thermal power occurs when module connected mode is enabled, the actual module thermal power depends, as module current consumption, on the radio access mode (GERAN / UTRA), the operating band and the average TX power. A few software techniques may be implemented to reduce the module temperature increase in the application: Select the radio access mode which provides lower temperature increase (see the module temperature increase values summarized above) by means of AT command (see the u-blox AT Commands Manual [2], +COPS command) Select the operating band which provides lower current consumption in the selected radio access mode (see current consumption values reported in the LISA-U2 series Data Sheet [1]) by means of AT command (see the u-blox AT Commands Manual [2], +UBANDSEL command) Enable module connected mode for a given time period and then disable it for a time period enough long to properly mitigate temperature increase UBX-13001118 - R19 Early Production Information Design-In Page 127 of 175 LISA-U2 series - System Integration Manual 2.4 Antenna guidelines Antenna characteristics are essential for good functionality of the module. Antenna radiating performance has direct impact on the reliability of connections over the Air Interface. A bad termination of the ANT pin (main RF input/output) and the ANT_DIV pin (RF input for diversity receiver provided by LISA-U230 modules) can result in poor performance of the module. The following parameters should be checked: Item Recommendations Impedance 50 Ω nominal characteristic impedance Frequency Range Input Power V.S.W.R Depends on the LISA-U2 module HW version and on the Mobile Network used. LISA-U260: 824..960 MHz (GSM 850, GSM 900, UMTS B5) 1710..1990 MHz (GSM 1800, GSM 1900, UMTS B2) LISA-U270: 824..960 MHz (GSM 850, GSM 900, UMTS B8) 1710..2170 MHz (GSM 1800, GSM 1900, UMTS B1) LISA-U200, LISA-U201, LISA-U230: 824..960 MHz (GSM 850, GSM 900, UMTS B5, UMTS B6, UMTS B8) 1710..2170 MHz (GSM 1800, GSM 1900, UMTS B1, UMTS B2, UMTS B4) >2 W peak <2:1 recommended, <3:1 acceptable Return Loss S11<-10 dB recommended, S11<-6 dB acceptable Table 46: General recommendation for GSM antenna The antenna gain shall remain below the levels reported in the section 1.15.2.2 to preserve the original u-blox FCC ID. Some 2G and 3G bands are overlapping. This depends on worldwide band allocation for telephony services, where different bands are deployed for different geographical regions. If LISA-U2 series modules are planned for use on the entire supported bands, then an antenna that supports the 824..960 MHz and the 1710..2170 MHz frequency range should be selected. Otherwise, for fixed applications in specific geographical region, antenna requirements can be relaxed for non-deployed frequency bands. See the operating RF frequency bands table in LISA-U2 series Data Sheet [1] for the detailed uplink and downlink frequency ranges of each supported band. LISA-U230 modules provide 2G and 3G dynamic receive diversity (Rx diversity) capability to improve the quality and reliability of the cellular link. This feature can be optionally used connecting a second antenna to the ANT_DIV pin, to receive an RF input signal that is processed by the module to increase the performance. It is recommended to properly connect the Rx diversity antenna to the ANT_DIV pin of LISA-U230 modules unless the 2G and 3G Rx diversity feature is disabled by AT command (see the u-blox AT Commands Manual [2], +URXDIV command). All the antenna guidelines and recommendations reported for the main Tx/Rx antenna design are applicable also to the Rx diversity antenna design, even if the antenna for the Rx diversity is not used to transmit. UBX-13001118 - R19 Early Production Information Design-In Page 128 of 175 LISA-U2 series - System Integration Manual GSM antennas are typically available as: Linear monopole: typical for fixed applications. The antenna extends mostly as a linear element with a dimension comparable to lambda/4 of the lowest frequency of the operating band. Magnetic base may be available. Cable or direct RF connectors are common options. The integration normally requires the fulfillment of some minimum guidelines suggested by antenna manufacturer Patch-like antenna: better suited for integration in compact designs (e.g. mobile phone). These are mostly custom designs where the exact definition of the PCB and product mechanical design is fundamental for tuning of antenna characteristics For integration observe these recommendations: Ensure 50 Ω antenna termination, minimize the V.S.W.R. or return loss, as this will optimize the electrical performance of the module. See sections 2.2.1.1 and 2.4.1 Select antenna with best radiating performance. See section 2.4.2 If a cable is used to connect the antenna radiating element to application board, select a short cable with minimum insertion loss. The higher the additional insertion loss due to low quality or long cable, the lower the connectivity Follow the recommendations of the antenna manufacturer for correct installation and deployment Do not include antenna within closed metal case Do not place the main antenna in close vicinity to end user since the emitted radiation in human tissue is limited by S.A.R. regulatory requirements Do not use directivity antenna since the electromagnetic field radiation intensity is limited in some countries Take care of interaction between co-located RF systems since the GSM transmitted power may interact or disturb the performance of companion systems Place antenna far from sensitive analog systems or employ countermeasures to reduce electromagnetic compatibility issues that may arise The antenna for the Rx diversity should be carefully separated from the main Tx/Rx antenna, because signal improvement is dependent on the cross correlation and the signal strength levels between the two received signals. The distance between the two antennas should be at least greater than half a wavelength of the lowest used frequency (i.e. distance greater than ~20 cm, for 2G/3G low bands) to distinguish between different multipath channels UBX-13001118 - R19 Early Production Information Design-In Page 129 of 175 LISA-U2 series - System Integration Manual 2.4.1 Antenna termination The LISA-U2 modules are designed to work on a 50 load. However, real antennas have no perfect 50 load on all the supported frequency bands. Therefore, to reduce as much as possible performance degradation due to antenna mismatch, the following requirements should be met: Measure the antenna termination with a network analyzer: connect the antenna through a coaxial cable to the measurement device, the |S11| indicates which portion of the power is delivered to antenna and which portion is reflected by the antenna back to the module output. A good antenna should have an |S11| below -10 dB over the entire frequency band. Due to miniaturization, mechanical constraints and other design issues, this value will not be achieved. An |S11| value of about -6 dB - (in the worst case) - is acceptable. Figure 63 shows an example of this measurement: Figure 63: |S11| sample measurement of a penta-band antenna that covers in a small form factor the 4 GSM bands (850 MHz, 900 MHz, 1800 MHz and 1900 MHz) and the UMTS Band I Figure 64 shows comparable measurements performed on a wideband antenna. The termination is better, but the size of the antenna is considerably larger. Figure 64: |S11| sample measurement of a wideband antenna UBX-13001118 - R19 Early Production Information Design-In Page 130 of 175 LISA-U2 series - System Integration Manual 2.4.2 Antenna radiation An indication of the antenna’s radiated power can be approximated by measuring the |S21| from a target antenna to the measurement antenna, using a network analyzer with a wideband antenna. Measurements should be done at a fixed distance and orientation, and results compared to measurements performed on a known good antenna. Figure 65 through Figure 66 show measurement results. A wideband log periodic-like antenna was used, and the comparison was done with a half lambda dipole tuned at 900 MHz frequency. The measurements show both the |S11| and |S21| for the penta-band internal antenna and for the wideband antenna. Figure 65: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a penta-band internal antenna (yellow/cyan) The half lambda dipole tuned at 900 MHz is known and has good radiation performance (both for gain and directivity). Then, by comparing the |S21| measurement with antenna under investigation for the frequency where the half dipole is tuned (e.g. marker 3 in Figure 65) it is possible to make a judgment on the antenna under test: if the performance is similar then the target antenna is good. Figure 66: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a wideband commercial antenna (yellow/cyan) Instead if |S21| values for the tuned dipole are much better than the antenna under evaluation (like for marker 1/2 area of Figure 66, where dipole is 5 dB better), then it can be argued that the radiation of the target antenna (the wideband dipole in this case) is considerably less. The same procedure should be repeated on other bands with half wavelength dipole re-tuned to the band under investigation. For good antenna radiation performance, antenna dimensions should be comparable to a quarter of the wavelength. Different antenna types can be used for the module, many of them (e.g. patch antennas, monopole) are based on a resonating element that works in combination with a ground plane. The ground plane, ideally infinite, can be reduced down to a minimum size that must be similar to one quarter of the wavelength of the minimum frequency that has to be radiated (transmitted/received). Numerical sample: frequency = 1 GHz wavelength = 30 cm minimum ground plane (or antenna size) = 7.5 cm. Below this size, the antenna efficiency is reduced. UBX-13001118 - R19 Early Production Information Design-In Page 131 of 175 LISA-U2 series - System Integration Manual 2.4.3 Examples of antennas Table 47 lists some examples of possible internal on-board surface-mount antennas Manufacturer Part Number Product Name Description Taoglas PA.25.A Anam Taoglas PA.710.A Warrior Taoglas PA.711.A Warrior II GSM / WCDMA SMD Antenna 824..960 MHz, 1710..2170 MHz 36.0 x 6.0 x 5.0 mm GSM / WCDMA / LTE SMD Antenna 698..960 MHz, 1710..2170 MHz, 2300..2400 MHz, 2490..2690 MHz 40.0 x 6.0 x 5.0 mm GSM / WCDMA / LTE SMD Antenna Pairs with the Taoglas PA.710.A Warrior for LTE MIMO applications 698..960 MHz, 1710..2170 MHz, 2300..2400 MHz, 2490..2690 MHz 40.0 x 6.0 x 5.0 mm Taoglas PCS.06.A Havok Antenova A10340 Calvus Ethertronics P522304 Prestta 2J 2JE04 Yaego ANT3505B000TWPENA GSM / WCDMA / LTE SMD Antenna 698..960 MHz, 1710..2170 MHz, 2500..2690 MHz 42.0 x 10.0 x 3.0 mm GSM / WCDMA SMD Antenna 824..960 MHz, 1710..2170 MHz 28.0 x 8.0 x 3.2 mm GSM / WCDMA SMD Antenna 824..960 MHz, 1710..2170 MHz 35.0 x 9.0 x 3.2 mm GSM / WCDMA SMD Antenna 824..960 MHz, 1710..2170 MHz 24.0 x 5.5 x 4.4 mm GSM / WCDMA SMD Antenna 824..960 MHz, 1710..2170 MHz 35.0 x 5.0 x 6.0 mm Table 47: Examples of internal surface-mount antennas Table 48 lists some examples of possible internal off-board PCB-type antennas with cable and connector. Manufacturer Part Number Taoglas FXP14.A.07.0100A Product Name Taoglas FXP14R.A.07.0100A Taoglas PC29.09.0100A Taoglas FXUB63.07.0150C Ethertronics P522310 Prestta EAD FSQS35241-UF-10 SQ7 Yaego ANTX100P001BWPEN3 TheStripe Description GSM / WCDMA PCB Antenna with cable and U.FL connector 824..960 MHz, 1710..2170 MHz 70.4 x 20.4 mm GSM / WCDMA PCB Antenna with cable and U.FL connector Integrated 10k shunt diagnostic resistor 824..960 MHz, 1710..2170 MHz 80.0 x 20.8 mm GSM / WCDMA PCB Antenna with cable and MMCX(M)RA connector 824..960 MHz, 1710..2170 MHz 80.4 x 29.4 mm GSM / WCDMA / LTE PCB Antenna with cable and U.FL connector 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2400..2690 MHz 96.0 x 21.0 mm GSM / WCDMA PCB Antenna with cable and U.FL connector 824..960 MHz, 1710..2170 MHz 41.0 x 15.0 mm GSM / WCDMA / LTE PCB Antenna with cable and U.FL connector 690..960 MHz, 1710..2170 MHz, 2500..2700 MHz 110.0 x 21.0 mm GSM / WCDMA PCB Antenna with cable and I-PEX connector 824..960 MHz, 1710..2170 MHz 50.0 x 20.0 mm Table 48: Examples of internal antennas with cable and connector UBX-13001118 - R19 Early Production Information Design-In Page 132 of 175 LISA-U2 series - System Integration Manual Table 49 lists some examples of possible external antennas. Manufacturer Part Number Product Name Description Taoglas GSA.8827.A.101111 Phoenix Taoglas GSA.8821.A.301721 I-Bar Taoglas TG.30.8112 GSM / WCDMA / LTE low-profile adhesive-mount Antenna with cable and SMA(M) connector 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2490..2690 MHz 105 x 30 x 7.7 mm GSM / WCDMA low-profile adhesive-mount Antenna with cable and Fakra (code-D) connector 824..960 MHz, 1710..2170 MHz 106.7 x 14.7 x 5.8 mm GSM / WCDMA / LTE swivel dipole Antenna with SMA(M) connector 698..960 MHz, 1575.42 MHz, 1710..2170 MHz, 2400..2700 MHz 148.6 x 49 x 10 mm Taoglas OMB.8912.03F21 Taoglas FW.92.RNT.M Nearson T6150AM Laird Tech. MAF94300 Laird Tech. TRA806/171033P Laird Tech. CMS69273 Laird Tech. OC69271-FNM Abracon APAMS-102 GSM / WCDMA pole-mount Antenna with N-type (F) connector 824..960 MHz, 1710..2170 MHz 527 x Ø 26 mm GSM / WCDMA whip monopole Antenna with RP-N-type(M) connector 824..960 MHz, 1710..2170 MHz 274 x Ø 20 mm GSM / WCDMA swivel monopole Antenna with SMA(M) connector 824..960 MHz, 1710..2170 MHz 179.3 x 22 x 6.5 mm HEPTA-SM GSM / WCDMA swivel monopole Antenna with SMA(M) connector 824..960 MHz, 1575.42 MHz,1710..2170 MHz, 2400..2500 MHz 161 x 9.3 mm GSM / WCDMA screw-mount Antenna with N-type(F) connector 824..960 MHz, 1710..2170 MHz 69.8 x Ø 38.1 mm GSM / WCDMA / LTE ceiling-mount Antenna with N-type(F) connector 698..960 MHz, 1575.42 MHz, 1710..2700 MHz 86 x Ø 199 mm GSM / WCDMA / LTE pole-mount Antenna with N-type(M) connector 698..960 MHz, 1710..2690 MHz 248 x Ø 24.5 mm GSM / WCDMA low-profile adhesive-mount Antenna with cable and SMA(M) connector 824..960 MHz, 1710..2170 MHz 138 x 21 x 6 mm Table 49: Examples of external antennas UBX-13001118 - R19 Early Production Information Design-In Page 133 of 175 LISA-U2 series - System Integration Manual 2.4.4 Antenna detection functionality The internal antenna detect circuit is based on ADC measurement at ANT: the RF port is DC coupled to the ADC unit in the baseband chip which injects a DC current (10 µA for 128 µs) on ANT and measures the resulting DC voltage to evaluate the resistance from ANT pad to GND. The antenna detection is forced by the +UANTR AT command: see the u-blox AT Commands Manual [2] for more details on how to access this feature. To achieve antenna detection functionality, use an RF antenna with built-in resistor from ANT signal to GND, or implement an equivalent solution with a circuit between the antenna cable connection and the radiating element as shown in Figure 67. Radiating Element DC Blocking Front-End RF Module Coaxial Antenna Cable ANT DC Blocking Zo=50 Ω RF Choke RF Choke Resistor for Diagnostic ADC Current Source Diagnostic Circuit LISA-U2 series Application Board Antenna Assembly Figure 67: Antenna detection circuit and antenna with diagnostic resistor Examples of components for the antenna detection diagnostic circuit are reported in the following table: Description Part Number - Manufacturer DC Blocking Capacitor Murata GRM1555C1H220JA01 or equivalent RF Choke Inductor Resistor for Diagnostic Murata LQG15HS68NJ02, LQG15HH68NJ02 or equivalent (Self Resonance Frequency ~1GHz) 15 k 5%, various Manufacturers Table 50: Example of components for the antenna detection diagnostic circuit The DC impedance at RF port for some antennas may be a DC open (e.g. linear monopole) or a DC short to reference GND (e.g. PIFA antenna). For those antennas, without the diagnostic circuit of Figure 67, the measured DC resistance will always be at the limits of the measurement range (respectively open or short), and there will be no mean to distinguish between a defect on antenna path with similar characteristics (respectively: removal of linear antenna or RF cable shorted to GND for PIFA antenna). Furthermore, any other DC signal injected to the RF connection from ANT connector to radiating element will alter the measurement and produce invalid results for antenna detection. It is recommended to use an antenna with a built-in diagnostic resistor in the range from 5 kΩ to 30 kΩ to assure good antenna detection functionality and to avoid a reduction of module RF performance. The choke inductor should exhibit a parallel Self Resonance Frequency (SRF) in the range of 1 GHz to improve the RF isolation of load resistor. UBX-13001118 - R19 Early Production Information Design-In Page 134 of 175 LISA-U2 series - System Integration Manual For example: Consider a GSM antenna with built-in DC load resistor of 15 k. Using the +UANTR AT command, the module reports the resistance value evaluated from ANT connector to GND: Reported values close to the used diagnostic resistor nominal value (i.e. values from 13 kΩ to 17 kΩ if a 15 kΩ diagnostic resistor is used) indicate that the antenna is properly connected Values close to the measurement range maximum limit (approximately 50 kΩ) or an open-circuit “over range” report (see u-blox AT Commands Manual [2]) means that that the antenna is not connected or the RF cable is broken Reported values below the measurement range minimum limit (1 kΩ) will highlight a short to GND at antenna or along the RF cable Measurement inside the valid measurement range and outside the expected range may indicate an improper connection, damaged antenna or wrong value of antenna load resistor for diagnostic Reported value could differ from the real resistance value of the diagnostic resistor mounted inside the antenna assembly due to antenna cable length, antenna cable capacity and the used measurement method 2.5 ESD guidelines 2.5.1 ESD immunity test overview The immunity of devices integrating LISA-U2 modules to Electro-Static Discharge (ESD) is part of the Electro-Magnetic Compatibility (EMC) conformity which is required for products bearing the CE marking, compliant with the R&TTE Directive (99/5/EC), the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms for device ESD immunity: ESD testing standard CENELEC EN 61000-4-2 [11] and the radio equipment standards ETSI EN 301 489-1 [12], ETSI EN 301 489-7 [13], ETSI EN 301 489-24 [14], which requirements are summarized in Table 51. The ESD immunity test is performed at the enclosure port, defined by ETSI EN 301 489-1 [12] as the physical boundary through which the electromagnetic field radiates. If the device implements an integral antenna, the enclosure port is defined as all insulating and conductive surfaces housing the device. If the device implements a removable antenna, the antenna port can be separated from the enclosure port. The antenna port includes the antenna element and its interconnecting cable surfaces. The applicability of the ESD immunity test to the whole device depends on the device classification as defined by ETSI EN 301 489-1 [12]. Applicability of the ESD immunity test to the specific device ports or the specific interconnecting cables to auxiliary equipments, depends on device accessible interfaces and manufacturer requirements, as defined by ETSI EN 301 489-1 [12]. Contact discharges are performed at conductive surfaces, while air discharges are performed at insulating surfaces. Indirect contact discharges are performed on the measurement setup horizontal and vertical coupling planes as defined in CENELEC EN 61000-4-2 [11]. For the definition of integral antenna, removable antenna, antenna port, device classification see the ETSI EN 301 489-1 [12]. The contact and air discharges are defined in CENELEC EN 61000-4-2 [11]. Application Category Immunity Level All exposed surfaces of the radio equipment and ancillary equipment in a representative configuration Contact Discharge 4 kV Air Discharge 8 kV Table 51: Electro-Magnetic Compatibility ESD immunity requirements as defined by CENELEC EN 61000-4-2, ETSI EN 301 489-1, ETSI EN 301 489-7, ETSI EN 301 489-24 UBX-13001118 - R19 Early Production Information Design-In Page 135 of 175 LISA-U2 series - System Integration Manual 2.5.2 ESD immunity test of u-blox LISA-U2 series reference designs Although Electro-Magnetic Compatibility (EMC) certification is required for customized devices integrating LISA-U2 modules for R&TTED and European Conformance CE mark, EMC certification (including ESD immunity) has been successfully performed on LISA-U2 series modules reference designs according to the CENELEC EN 61000-4-2 [11], ETSI EN 301 489-1 [12], ETSI EN 301 489-7 [13] and ETSI EN 301 489-24 [14] European Norms. The EMC / ESD approved u-blox reference designs consist of a LISA-U2 series module soldered onto a motherboard which provides supply interface, SIM card, headset and communication port. An external antenna is connected to an SMA connector provided on the motherboard for the main Tx/Rx antenna. An additional external antenna is connected to an additional SMA connector provided on the motherboard for the Rx diversity antenna of LISA-U230 modules. Since an external antenna is used, the antenna port can be separated from the enclosure port. The reference design is not enclosed in a box so that the enclosure port is not indentified with physical surfaces. Therefore, some test cases cannot be applied. Only the antenna port is identified as accessible for direct ESD exposure. The u-blox LISA-U2 series reference designs implement all the ESD precautions described in section 2.5.3. u-blox LISA-U2 series reference designs ESD immunity test results are reported in the Table 52, according to test requirements stated in the CENELEC EN 61000-4-2 [11], ETSI EN 301 489-1 [12], ETSI EN 301 489-7 [13] and ETSI EN 301 489-24 [14]. Category Application Ref. Design Immunity Level Contact Discharge to coupling planes (indirect contact discharge) Enclosure All +4 kV / -4 kV Contact Discharges to conducted surfaces (direct contact discharge) Enclosure port All Not Applicable Test not applicable to u-blox reference design because it does not provide enclosure surface. The test is applicable only to equipments providing conductive enclosure surface. Main Antenna port All +4 kV / -4 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with conductive surface. Rx Div Antenna port LISA-U230 +4 kV / -4 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with conductive surface. Enclosure port All Not Applicable Test not applicable to the u-blox reference design because it does not provide an enclosure surface. The test is applicable only to equipments providing insulating enclosure surface. Main Antenna port All +8 kV / -8 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with insulating surface. Rx Div Antenna port LISA-U230 +8 kV / -8 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with insulating surface. Air Discharge at insulating surfaces Remarks Table 52: Enclosure ESD immunity level of u-blox LISA-U2 series modules reference designs UBX-13001118 - R19 Early Production Information Design-In Page 136 of 175 LISA-U2 series - System Integration Manual 2.5.3 ESD application circuits The application circuits described in this section are recommended and should be implemented in any device that integrates a LISA-U2 module, according to the application board classification (see ETSI EN 301 489-1 [12]), to satisfy the requirements for ESD immunity test summarized in Table 51. Antenna interface The ANT pin of LISA-U2 modules provides ESD immunity up to 1000 V (contact and air discharge according to IEC 61000-4-2): higher protection level is required if the line is externally accessible on the device (i.e. the application board where LISA-U2 series module is mounted). The following precautions are suggested for satisfying ESD immunity test requirements using LISA-U2 series modules: If the device implements an embedded antenna, the device insulating enclosure should provide protection to direct contact discharge up to +4 kV / -4 kV and protection to air discharge up to +8 kV / -8 kV to the antenna interface If the device implements an external antenna, the antenna and its connecting cable should provide a completely insulated enclosure able to provide protection to direct contact discharge up to +4 kV / -4 kV and protection to air discharge up to +8 kV / -8 kV to the whole antenna and cable surfaces If the device implements an external antenna and the antenna and its connecting cable do not provide a completely insulated enclosure able to provide protection to direct contact discharge up to +4 kV / -4 kV and protection to air discharge up to +8 kV / -8 kV to the whole antenna and cable surfaces, an external high pass filter, consisting of a series 15 pF capacitor (Murata GRM1555C1H150JA01) and a shunt 39 nH coil (Murata LQG15HN39NJ02) should be implemented at the antenna port as described in Figure 68, as implemented in the EMC / ESD approved reference design LISA-U2 series modules Antenna detection functionality is not provided when implementing the high pass filter described in Figure 68 and Table 53 as ESD protection for the antenna port of LISA-U2 series modules. Radiating Element Coaxial Antenna Cable ANT Zo = 50 Ohm External Antenna Enclosure LISA-U2 series Antenna Port Application Board Enclosure Port Figure 68: Antenna port ESD immunity protection application circuit for LISA-U2 series modules Reference Description Part Number - Manufacturer 15 pF Capacitor Ceramic C0G 0402 5% 50 V 39 nH Multilayer Chip Inductor L0G 0402 5% GRM1555C1H150JA01 - Murata LQG15HN39NJ02 - Murata Table 53: Example of components for Antenna port ESD immunity protection application circuit for LISA-U2 series modules UBX-13001118 - R19 Early Production Information Design-In Page 137 of 175 LISA-U2 series - System Integration Manual With LISA-U230 modules, the ANT_DIV pin provides ESD immunity up to +4 kV / -4 kV for direct Contact Discharge and up to +8 kV / -8 kV for Air Discharge: no further precaution to ESD immunity test is needed, as implemented in the EMC / ESD approved reference design of LISA-U230 modules. RESET_N pin The following precautions are suggested for the RESET_N line of LISA-U2 modules, depending on the application board handling, to satisfy ESD immunity test requirements: A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) must be mounted on the line termination connected to the RESET_N pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure A proper series chip ferrite bead noise/EMI suppression filter (e.g. Murata BLM15HD182SN1) must be added on the line connected to the RESET_N pin to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure A 220 nF bypass capacitor (e.g. Murata GRM155R60J224KE01) must be mounted as close as possible to the RESET_N pin of LISA-U2 series modules to avoid a module reset caused by an electrostatic discharge applied to the application board enclosure It is recommended to keep the connection line to RESET_N as short as possible Maximum ESD sensitivity rating of the RESET_N pin is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the RESET_N pin is externally accessible on the application board. The following precautions are suggested to achieve higher protection level: A general purpose ESD protection device (e.g. EPCOS CA05P4S14THSG varistor array or EPCOS CT0402S14AHSG varistor) should be mounted on the RESET_N line, close to accessible point The RESET_N application circuit implemented in the EMC / ESD approved reference designs of LISA-U2 series moduels is described in Figure 20 and Table 19 (section 1.6.3). SIM interface The following precautions are suggested for LISA-U2 modules SIM interface (VSIM, SIM_RST, SIM_IO, SIM_CLK pins), depending on the application board handling, to satisfy ESD immunity test requirements: A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470J) must be mounted on the lines connected to VSIM, SIM_RST, SIM_IO and SIM_CLK pins to assure SIM interface functionality when an electrostatic discharge is applied to the application board enclosure It is suggested to use as short as possible connection lines at SIM pins Maximum ESD sensitivity rating of SIM interface pins is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if SIM interface pins are externally accessible on the application board. The following precautions are suggested to achieve higher protection level: A low capacitance (i.e. less than 10 pF) ESD protection device (e.g. Infineon ESD8V0L2B-03L or AVX USB0002) should be mounted on each SIM interface line, close to accessible points (i.e. close to the SIM card holder) The SIM interface application circuit implemented in the EMC / ESD approved reference designs of LISA-U2 series modules versions is described in the section 1.8.1. Other pins and interfaces All the module pins that are externally accessible on the device integrating LISA-U2 module should be included in the ESD immunity test since they are considered to be a port as defined in ETSI EN 301 489-1 [12]. Depending on applicability, to satisfy ESD immunity test requirements according to ESD category level, all the module pins that are externally accessible should be protected up to +4 kV / -4 kV for direct Contact Discharge and up to +8 kV / -8 kV for Air Discharge applied to the enclosure surface. UBX-13001118 - R19 Early Production Information Design-In Page 138 of 175 LISA-U2 series - System Integration Manual The maximum ESD sensitivity rating of all the other pins of the module is 1 kV (Human Body Model according to JESD22-A114F). Higher protection level could be required if the relevant pin is externally accessible on the application board. The following precautions are suggested to achieve higher protection level: USB interface: a very low capacitance (i.e. less or equal to 1 pF) ESD protection device (e.g. Tyco Electronics PESD0402-140 ESD protection device) should be mounted on the USB_D+ and USB_D- lines, close to the accessible points (i.e. close to the USB connector) SPI interface: a low capacitance (i.e. less than 10 pF) ESD protection device (e.g. Infineon ESD8V0L2B-03L or AVX USB0002) should be mounted on the SPI_MISO, SPI_MOSI, SPI_SCLK, SPI_MRDY, SPI_SRDY lines, close to accessible points CODEC_CLK: a low capacitance (i.e. less than 10 pF) ESD protection device (e.g. Infineon ESD8V0L2B-03L or AVX USB0001) should be mounted on the CODEC_CLK line, close to accessible point Other pins: a general purpose ESD protection device (e.g. EPCOS CA05P4S14THSG varistor array or EPCOS CT0402S14AHSG varistor) should be mounted on the related line, close to accessible point UBX-13001118 - R19 Early Production Information Design-In Page 139 of 175 LISA-U2 series - System Integration Manual 3 Features description 3.1 Network indication The GPIO1, GPIO2, GPIO3, GPIO4 or GPIO5 alternatively from their default settings, can be configured to indicate network status (i.e. no service, registered home network, registered visitor network, voice or data call enabled), by means of the AT+UGPIOC command. For the detailed description, see section 1.12 and to u-blox AT Commands Manual [2], GPIO commands. 3.2 Antenna detection Antenna presence detection capability is provided, evaluating the resistance from the ANT pin to GND by means of an internal antenna detection circuit. The external antenna assembly must be provided with a built-in resistor (diagnostic circuit) to be detected. The antenna detection feature can be enabled through the +UANTR AT command. For more details regarding feature description and diagnostic circuit design-in see the section 2.4.4, and the u-blox AT Commands Manual [2]. 3.3 Jamming Detection In real network situations modules can experience various kind of out-of-coverage conditions: limited service conditions when roaming to networks not supporting the specific SIM, limited service in cells which are not suitable or barred due to operators’ choices, no cell condition when moving to poorly served or highly interfered areas. In the latter case, interference can be artificially injected in the environment by a noise generator covering a given spectrum, thus obscuring the operator’s carriers entitled to give access to the GSM/UMTS service. The Jamming Detection Feature detects such “artificial” interference and reports the start and stop of such conditions to the client, which can react appropriately by e.g. switching off the radio transceiver in order to reduce power consumption and monitoring the environment at constant periods. The feature consists of detecting, at radio resource level, an anomalous source of interference and signaling it to the client with an unsolicited indication when the detection is entered or released. The jamming condition occurs when: The module has lost synchronization with the serving cell and cannot select any other cell The band scan reveals at least n carriers with power level equal or higher than threshold On all such carriers, no synchronization is possible The number of minimum disturbing carriers and the power level threshold can be configured by the client by using the AT+UCD command [2]. The jamming condition is cleared when any of the above mentioned statements does not hold. The congestion (i.e. jamming) detection feature can be enabled and configured by the +UCD AT command (for more details see the u-blox AT Commands Manual [2]). UBX-13001118 - R19 Early Production Information Features description Page 140 of 175 LISA-U2 series - System Integration Manual 3.4 TCP/IP and UDP/IP Via the AT commands it is possible to access the TCP/IP and UDP/IP functionalities over the Packet Switched data connection. For more details about AT commands see the u-blox AT Commands Manual [2]. LISA-U2 modules support the Direct Link mode for TCP and UDP sockets. Sockets can be set in Direct Link mode to establish a transparent end-to-end communication with an already connected TCP or UDP socket via serial interface. In Direct Link mode, data sent to the serial interface from an external application processor is forwarded to the network and vice-versa. To avoid data loss while using Direct Link, enable HW flow control on the serial interface. 3.4.1 Multiple PDP contexts and sockets Two PDP context types are defined: “external” PDP context: IP packets are built by the DTE, the MT’s IP instance runs the IP relay function only “internal” PDP context: the PDP context (relying on the MT’s TCP/IP stack) is configured, established and handled via the data connection management packet switched data commands described in u-blox AT commands manual [2] Multiple PDP contexts are supported. The DTE can access these PDP contexts either alternatively through the physical serial port, or simultaneously through the virtual serial ports of the multiplexer (multiplexing mode MUX), with the following constraints: Using the MT’s embedded TCP/IP stack, only 1 internal PDP context is supported. This IP instance supports up to 7 sockets Using only external PDP contexts, it is possible to have at most 3 IP instances (with 3 different IP addresses) simultaneously. If in addition the internal PDP context is used, at most 2 external PDP contexts can be activated Secondary PDP contexts (PDP contexts sharing the IP address of a primary PDP context) are also supported. Traffic Flow Filters for such secondary contexts shall be specified according to 3GPP TS 23.060 [19]. At most 2 secondary PDP contexts can be activated, since the maximum number of PDP contexts, both normal and secondary, is always 3. 3.5 FTP LISA-U2 modules support the File Transfer Protocol and Secure File Transfer Protocol functionalities via AT commands. Files are read and stored in the local file system of the module. For more details about AT commands see u-blox AT Commands Manual [2]. FTP files can also be transferred using FTP Direct Link: FTP download: the data coming from the FTP server is forwarded to the application processor via the serial interface (for FTP without Direct Link mode the data is always stored in the module’s FFS) FTP upload: the data coming from the application processor via the serial interface is forwarded to the FTP server (for FTP without Direct Link mode the data is read from the module’s FFS) When Direct Link is used for a FTP file transfer, only the file content pass through the serial interface, whereas all the FTP commands handling is managed internally by the FTP application. Due to the limited size of module FFS, FTP direct link is useful to transfer files with size greater than FFS. To avoid data loss while using direct link, enable HW flow control on the serial interface. 3.6 HTTP LISA-U2 modules support Hyper-Text Transfer Protocol (HTTP/1.0) functionalities as an HTTP client is implemented: HEAD, GET, POST, DELETE and PUT operations are available. The file size to be uploaded / downloaded depends on the free space available in the local file system (FFS) at the moment of the operation. Up to 4 HTTP client contexts can simultaneously be used. UBX-13001118 - R19 Early Production Information Features description Page 141 of 175 LISA-U2 series - System Integration Manual LISA-U2 modules support also Secure Hyper-Text Transfer Protocol functionalities providing SSL encryption. For more details about AT commands see the u-blox AT Commands Manual [2]. 3.7 SSL/TLS The modules support the Secure Sockets Layer (SSL) / Transport Layer Security (TLS) with certificate key sizes up to 4096 bits to provide security over the FTP and HTTP protocols. The SSL/TLS support provides different connection security aspects: Server authentication : use of the server certificate verification against a specific trusted certificate or a trusted certificates list Client authentication : use of the client certificate and the corresponding private key Data security and integrity: data encryption and Hash Message Authentication Code (HMAC) generation 10 10 The security aspects used during a connection depend on the SSL/TLS configuration and features supported. Table 55 contains the settings of the default SSL/TLS profile and Table 55 to Table 59 report the main SSL/TLS supported capabilities of the products. For a complete list of supported configurations and settings see the u-blox AT Commands Manual [2]. Settings Value Meaning Certificates validation level Level 0 The server certificate will not be checked or verified Minimum SSL/TLS version Any The server can use any of the TLS1.0/TLS1.1/TLS1.2 versions for the connection Cipher suite Automatic The cipher suite will be negotiated in the handshake process Trusted root certificate internal name Expected server host-name None None No certificate will be used for the server authentication No server host-name is expected Client certificate internal name Client private key internal name None None No client certificate will be used No client private key will be used Client private key password None No client private key password will be used Pre-shared key None No pre-shared key password will be used Table 54: Default SSL/TLS profile SSL/TLS Version Supported feature SSL 2.0 SSL 3.0 NO YES TLS 1.0 TLS 1.1 YES YES10 TLS 1.2 YES10 Table 55: SSL/TLS version support Algorithm Supported feature RSA PSK YES10 YES Table 56: Authentication 10 Not supported by "01", "x2" and "68" product versions UBX-13001118 - R19 Early Production Information Features description Page 142 of 175 LISA-U2 series - System Integration Manual Algorithm Supported feature RC4 DES NO11 YES 3DES AES128 YES10 YES AES256 YES10 Table 57: Encryption Algorithm Supported feature MD5 NO11 SHA/SHA1 SHA256 YES YES10 SHA384 YES10 Table 58: Message digest Description Registry value Supported feature TLS_RSA_WITH_AES_128_CBC_SHA 0x00,0x2F YES10 TLS_RSA_WITH_AES_128_CBC_SHA256 0x00,0x3C YES10 TLS_RSA_WITH_AES_256_CBC_SHA TLS_RSA_WITH_AES_256_CBC_SHA256 0x00,0x35 0x00,0x3D YES10 YES10 TLS_RSA_WITH_3DES_EDE_CBC_SHA 0x00,0x0A YES10 TLS_RSA_WITH_RC4_128_MD5 TLS_RSA_WITH_RC4_128_SHA 0x00,0x04 0x00,0x05 NO11 NO11 TLS_PSK_WITH_AES_128_CBC_SHA TLS_PSK_WITH_AES_256_CBC_SHA 0x00,0x8C 0x00,0x8D YES10 YES10 TLS_PSK_WITH_3DES_EDE_CBC_SHA TLS_RSA_PSK_WITH_AES_128_CBC_SHA 0x00,0x8B 0x00,0x94 YES10 YES10 TLS_RSA_PSK_WITH_AES_256_CBC_SHA 0x00,0x95 YES10 TLS_RSA_PSK_WITH_3DES_EDE_CBC_SHA TLS_PSK_WITH_AES_128_CBC_SHA256 0x00,0x93 0x00,0xAE YES10 YES10 TLS_PSK_WITH_AES_256_CBC_SHA384 TLS_RSA_PSK_WITH_AES_128_CBC_SHA256 0x00,0xAF 0x00,0xB6 YES10 YES10 TLS_RSA_PSK_WITH_AES_256_CBC_SHA384 0x00,0xB7 YES10 Table 59: TLS cipher suite registry 3.8 Dual stack IPv4/IPv6 Not supported by "01", "x2" and "68" product versions. LISA-U2 modules support both Internet Protocol version 4 and Internet Protocol version 6. For more details about dual stack IPv4/IPv6 see the u-blox AT Commands Manual [2]. 11 Supported only by "01", "x2" and "68" product versions UBX-13001118 - R19 Early Production Information Features description Page 143 of 175 LISA-U2 series - System Integration Manual 3.9 AssistNow clients and GNSS integration For customers using u-blox GNSS receivers, LISA-U2 cellular modules feature embedded AssistNow clients. AssistNow A-GPS provides better GNSS performance and faster Time-To-First-Fix. The clients can be enabled and disabled with an AT command (see the u-blox AT Commands Manual [2]). LISA-U2 modules act as a stand-alone AssistNow client, making AssistNow available with no additional requirements for resources or software integration on an external host micro controller. Full access to u-blox GNSS receivers is available via the LISA-U2 series, through a dedicated DDC (I C) interface, while the available GPIOs can handle the positioning chipset / module power-on/off. This means that GSM/WCDMA and GNSS can be controlled through a single serial port from any host processor. 3.10 Hybrid positioning and CellLocate® Although GNSS is a widespread technology, its reliance on the visibility of extremely weak GNSS satellite signals means that positioning is not always possible. Especially difficult environments for GNSS are indoors, in enclosed or underground parking garages, as well as in urban canyons where GNSS signals are blocked or jammed by multipath interference. The situation can be improved by augmenting GNSS receiver data with cellular network information to provide positioning information even when GNSS reception is degraded or absent. This additional information can benefit numerous applications. 3.10.1 Positioning through cellular information: CellLocate® ® u-blox CellLocate enables the estimation of device position based on the parameters of the mobile network cells ® visible to the specific device. To estimate its position the u-blox cellular module sends the CellLocate server the parameters of network cells visible to it using a UDP connection. In return the server provides the estimated ® position based on the CellLocate database. The u-blox cellular module can either send the parameters of the visible home network cells only (normal scan) or the parameters of all surrounding cells of all mobile operators (deep scan). Normal scan is only possible in 2G mode. ® The CellLocate database is compiled from the position of devices which observed, in the past, a specific cell or set of cells (historical observations) as follows: ® 1. Several devices reported their position to the CellLocate server when observing a specific cell (the As in the picture represent the position of the devices which observed the same cell A) UBX-13001118 - R19 Early Production Information Features description Page 144 of 175 LISA-U2 series - System Integration Manual ® 2. CellLocate server defines the area of Cell A visibility ® 3. If a new device reports the observation of Cell A CellLocate is able to provide the estimated position from the area of visibility 4. The visibility of multiple cells provides increased accuracy based on the intersection of areas of visibility. ® ® CellLocate is implemented using a set of two AT commands that allow configuration of the CellLocate service (AT+ULOCCELL) and requesting position according to the user configuration (AT+ULOC). The answer is provided in the form of an unsolicited AT command including latitude, longitude and estimated accuracy. ® The accuracy of the position estimated by CellLocate depends on the availability of historical observations in the specific area. UBX-13001118 - R19 Early Production Information Features description Page 145 of 175 LISA-U2 series - System Integration Manual 3.10.2 Hybrid positioning With u-blox Hybrid positioning technology, u-blox cellular devices can be triggered to provide their current ® position using either a u-blox GNSS receiver or the position estimated from CellLocate . The choice depends on which positioning method provides the best and fastest solution according to the user configuration, exploiting the benefit of having multiple and complementary positioning methods. Hybrid positioning is implemented through a set of three AT commands that allow configuration of the GNSS ® receiver (AT+ULOCGNSS), configuration of the CellLocate service (AT+ULOCCELL), and requesting the position according to the user configuration (AT+ULOC). The answer is provided in the form of an unsolicited AT command including latitude, longitude and estimated accuracy (if the position has been estimated by ® CellLocate ), and additional parameters if the position has been computed by the GNSS receiver. The configuration of mobile network cells does not remain static (e.g. new cells are continuously added or existing cells are reconfigured by the network operators). For this reason, when a Hybrid positioning method has been triggered and the GNSS receiver calculates the position, a database self-learning mechanism has been implemented so that these positions are sent to the server to update the database and maintain its accuracy. The use of hybrid positioning requires a connection via the DDC (I C) bus between the LISA-U2 cellular module and the u-blox GNSS receiver (see section 1.10). See the GNSS Implementation Application Note [16] for the complete description of the feature. ® u-blox is extremely mindful of user privacy. When a position is sent to the CellLocate server u-blox is unable to track the SIM used or the specific device. 3.11 Control Plane Aiding / Location Services (LCS) Not supported by "01", "x2" and "68" product versions With the Assisted GPS feature, a location server provides the module with the GPS system information that otherwise has to be downloaded from satellites. The feature allows faster position fixes, increases sensitivity and reduces module power consumption. The feature is invoked by the module through LCS Supplementary Services or by the Network during emergency calls. The assisted GPS Location Services feature is based on the Radio Resources Location Protocol (RRLP), according to 3GPP TS 44.031 [27], and Radio Resource Control (RRC) according to 3GPP TS 25.331 [28]. For more details, see the u-blox AT Commands Manual [2]. 3.12 Firmware (upgrade) Over AT (FOAT) 3.12.1 Overview This feature allows upgrading the module Firmware over UART, USB and SPI interfaces, using AT Commands. AT Command AT+UFWUPD triggers a reboot followed by the upgrade procedure at specified a baud rate (see the u-blox AT Commands Manual [2] for more details) The Xmodem-1k protocol is used for downloading the new Firmware image via a terminal application A special boot loader on the module performs firmware installation, security verifications and module reboot Firmware authenticity verification is performed via a security signature during the download. The firmware is then installed, overwriting the current version. In case of power loss during this phase, the boot loader detects a fault at the next wake-up, and restarts the firmware download from the Xmodem-1k handshake. After completing the upgrade, the module is reset again and wakes-up in normal boot UBX-13001118 - R19 Early Production Information Features description Page 146 of 175 LISA-U2 series - System Integration Manual 3.12.2 FOAT procedure The application processor must proceed in the following way: Send the AT+UFWUPD command through the UART or over the USB interface, specifying the file type and the desired baud rate Reconfigure the serial communication at the selected baud rate, without flow control with the Xmodem-1k protocol Send the new FW image via Xmodem-1k 3.13 In-Band modem (eCall / ERA-GLONASS) Not supported by supported by "01", "x2" and "68" product versions. LISA-U2 module supports an In-Band modem solution for eCall and ERA-GLONASS emergency call applications over cellular networks, implemented according to 3GPP TS 26.267 [24], BS EN 16062:2011 [25] and ETSI TS 122 101 [26] specifications. eCall (European) and ERA-GLONASS (Russian) are initiatives to combine mobile communications and satellite positioning to provide rapid assistance to motorists in the event of a collision, implementing automated emergency response system based the first on GPS the latter on GLONASS positioning system. When activated, the in-vehicle systems (IVS) automatically initiate an emergency call carrying both voice and data (including location data) directly to the nearest Public Safety Answering Point (PSAP) to determine whether rescue services should be dispatched to the known position. Figure 69: eCall and ERA-GLONASS automated emergency response systems diagram flow 3.14 SIM Access Profile (SAP) SIM access profile (SAP) feature allows LISA-U2 modules to access and use a remote (U)SIM card instead of the local SIM card directly connected to the module (U)SIM interface. LISA-U2 modules provide a dedicated USB SAP channel and dedicated multiplexer SAP channel over UART and SPI for communication with the remote (U)SIM card. The communication between LISA-U2 modules and the remote SIM is conformed to client-server paradigm: LISA-U2 module is the SAP client establishing a connection and performing data exchange to an SAP server directly connected to the remote SIM that is used by LISA-U2 module for GSM/UMTS network operations. SAP communication protocol is based on the SIM Access Profile Interoperability Specification [22]. LISA-U2 modules do not support SAP server role: the module acts as SAP client only. UBX-13001118 - R19 Early Production Information Features description Page 147 of 175 LISA-U2 series - System Integration Manual A typical application using the SAP feature is the scenario where a device such as an embedded car-phone with an integrated LISA-U2 module uses a remote SIM included in an external user device (e.g. a simple SIM card reader or a portable phone), which is brought into the car. The car-phone accesses the GSM/UMTS network using the remote SIM in the external device. LISA-U2 modules, acting as an SAP client, can be connected to an SAP server by a completely wired connection, as shown in Figure 70. Device including SIM Mobile Equipment SAP Server Device including LISA SAP Serial Interface Application Processor SAP Serial Interface (USB SAP channel, or MUX SAP channel over UART or SPI) LISA module SAP Client GSM/UMTS Interface Local SIM Remote SIM (optional) Figure 70: Remote SIM access via completely wired connection As stated in the SIM Access Profile Interoperability Specification [22], the SAP client can be connected to the SAP server by means of a Bluetooth cellular link, using additional Bluetooth transceivers. In this case, the application processor wired to LISA-U2 modules establishes and controls the Bluetooth connection using the SAP profile, and routes data received over a serial interface channel to data transferred over a Bluetooth interface and vice versa, as shown in Figure 71. Device including SIM Mobile Equipment SAP Server Bluetooth Transceiver Device including LISA SAP Bluetooth Interface Bluetooth Transceiver Application Processor SAP Serial Interface LISA module (USB SAP channel, or MUX SAP channel over UART or SPI) SAP Client GSM/UMTS Interface Local SIM Remote SIM (optional) Figure 71: Remote SIM access via Bluetooth and wired connection The application processor can start an SAP connection negotiation between LISA-U2 module SAP client and an SAP server using custom AT command (for more details see the u-blox AT Commands Manual [2]). While the connection with the SAP server is not fully established, the LISA-U2 module continues to operate with the attached (local) SIM, if present. Once the connection is established and negotiated, the LISA-U2 module performs a detach operation from the local SIM followed by an attach operation to the remote one. Then the remotely attached SIM is used for any GSM/UMTS network operation. URC indications are provided to inform the user about the state of both the local and remote SIM. The insertion and the removal of the local SIM card are notified if a proper card presence detection circuit using the GPIO5 of LISA-U2 modules is implemented as shown in the section 1.8.1, and if the related “SIM card detection” and “SIM hot insertion/removal” functions are enabled by AT commands (for more details see the u-blox AT Commands Manual [2], +UGPIOC, +UDCONF=50 AT commands). Upon SAP deactivation, the LISA-U2 modules perform a detach operation from the remote SIM followed by an attach operation to the local one, if present. UBX-13001118 - R19 Early Production Information Features description Page 148 of 175 LISA-U2 series - System Integration Manual 3.15 Smart Temperature Management Cellular modules – independent of the specific model – always have a well defined operating temperature range. This range should be respected to guarantee full device functionality and long life span. Nevertheless there are environmental conditions that can affect operating temperature, e.g. if the device is located near a heating/cooling source, if there is/isn’t air circulating, etc. The module itself can also influence the environmental conditions; such as when it is transmitting at full power. In this case its temperature increases very quickly and can raise the temperature nearby. The best solution is always to properly design the system where the module is integrated. Nevertheless an extra check/security mechanism embedded into the module is a good solution to prevent operation of the device outside of the specified range. 3.15.1 Smart Temperature Supervisor (STS) The Smart Temperature Supervisor is activated and configured by a dedicated AT+USTS command. See the u-blox AT Commands Manual [2] for more details. The cellular module measures the internal temperature (Ti) and its value is compared with predefined thresholds to identify the actual working temperature range. Temperature measurement is done inside the cellular module: the measured value could be different from the environmental temperature (Ta). Valid temperature range Dangerous area Warning area t-2 Safe area t-1 Warning area t+1 Dangerous area t+2 Figure 72: Temperature range and limits The entire temperature range is divided into sub-regions by limits (see Figure 72) named t-2, t-1, t+1 and t+2. Within the first limit, (t-1 < Ti < t+1), the cellular module is in the normal working range, the Safe Area In the Warning Area, (t-2 < Ti < t.1) or (t+1 < Ti < t+2), the cellular module is still inside the valid temperature range, but the measured temperature approaches the limit (upper or lower). The module sends a warning to the user (through the active AT communication interface), which can take, if possible, the necessary actions to return to a safer temperature range or simply ignore the indication. The module is still in a valid and good working condition Outside the valid temperature range, (Ti < t -2) or (Ti > t+2), the device is working outside the specified range and represents a dangerous working condition. This condition is indicated and the device shuts down to avoid damage For security reasons the shutdown is suspended in case an emergency call in progress. In this case the device will switch off at call termination. The user can decide at anytime to enable/disable the Smart Temperature Supervisor feature. If the feature is disabled there is no embedded protection against disallowed temperature conditions. UBX-13001118 - R19 Early Production Information Features description Page 149 of 175 LISA-U2 series - System Integration Manual Figure 73 shows the flow diagram implemented in LISA-U2 modules for the Smart Temperature Supervisor. No IF STS enabled Feature disabled: no action Yes Feature enabled (full logic or indication only) Read temperature Yes Temperature is within normal operating range No No further actions IF (t-1 , parameters). These kinds of test may be useful as a ‘go/no go’ test but not for RF performance measurements. This test is suitable to check the communication with host controller and SIM card, the audio and power supply functionality and verify if components at antenna interface are well soldered. 5.2.2 Functional tests providing RF operation Overall RF performance test of the device including antenna can be performed with basic instruments such as a spectrum analyzer (or an RF power meter) and a signal generator using AT+UTEST command over AT interface. The AT+UTEST command gives a simple interface to set the module to Rx and Tx test modes ignoring 2G/3G signaling protocol. The command can set the module: In transmitting mode in a specified channel and power level in all supported modulation schemes (single slot GMSK, single slot 8PSK, WCDMA) and bands 2G, 3G In receiving mode in a specified channel to returns the measured power level in all supported bands 2G, 3G See the u-blox AT Commands Manual [2], for AT+UTEST command syntax description. See the End user test Application Note [20], for AT+UTEST command user guide, limitations and examples of use. UBX-13001118 - R19 Early Production Information Product Testing Page 158 of 175 LISA-U2 series - System Integration Manual Wireless Antenna Application Processor Wideband Antenna LISA-U2 series IN Spectrum Analyzer or Power Meter OUT Signal Generator AT Commands ANT TX Application Board Wireless Antenna Application Processor Wideband Antenna LISA-U2 series AT Commands ANT RX Application Board Figure 76: Setup with spectrum analyzer and signal generator for radiated measurement This feature allows the measurement of the transmitter and receiver power levels to check component assembly related to the module antenna interface and to check other device interfaces from which depends the RF performance. To avoid module damage during transmitter test, a proper antenna according to module specifications or a 50 Ω termination must be connected to ANT pin. To avoid module damage during receiver test the maximum power level received at ANT pin must meet module specifications. The AT+UTEST command sets the module to emit RF power ignoring 2G/3G signalling protocol. This emission can generate interference that can be prohibited by law in some countries. The use of this feature is intended for testing purpose in controlled environments by qualified user and must not be used during the normal module operation. Follow instructions suggested in u-blox documentation. u-blox assumes no responsibilities for the inappropriate use of this feature. Example of production tests for OEM manufacturer: 1. Trigger TX GMSK burst at low Power Control Level (lower than 15) or a RX measure reporting to check: If ANT pin is soldered If ANT pin is in short circuit If module was damaged during soldering process or during handling (ESD, mechanical shock…) If antenna matching components on application board are soldered If integrated antenna is correctly connected UBX-13001118 - R19 Early Production Information Product Testing Page 159 of 175 LISA-U2 series - System Integration Manual To avoid module damage during transmitter test when good antenna termination is not guaranteed, use a low Power Control Level (i.e. PCL lower or equal to 15). u-blox assumes no responsibilities for module damaging caused by an inappropriate use of this feature. 2. Trigger TX GMSK burst at maximum PCL: To check if the power supply is correctly assembled and is able to deliver the required current 3. Trigger TX GMSK and 8PSK burst and WCDMA signal: To measure current consumption To check if module components was damaged during soldering process or during handling (ESD, mechanical shock…) 4. Trigger RX measurement: To test receiver signal level. Assuming that there are no losses between ANT pin or ANT_DIV pin and input power source, be aware that the power level estimated by the module can vary approximately within 3GPP tolerances for the average value To check if module was damaged during soldering process or during handling (ESD, mechanical shock…) 5. Trigger TX GMSK and 8PSK burst and WCDMA signal and RX measurement to check: Overall RF performance of the device including antenna measuring TX and RX power levels UBX-13001118 - R19 Early Production Information Product Testing Page 160 of 175 LISA-U2 series - System Integration Manual Appendix A Migration from LISA-U1 to LISA-U2 series Migrating LISA-U1 series designs to LISA-U2 series modules is a straight forward procedure. Nevertheless there are some points to be considered during the migration. A.1 Checklist for migration Have you chosen the optimal module? For HSDPA category 14, 6-band 3G, Digital Audio Interfaces support, select a LISA-U230 module. For HSDPA category 8, 6-band 3G, Digital Audio Interfaces support, select a suitable LISA-U200 module. For HSDPA category 8, 5-band 3G, Digital Audio Interfaces support, select LISA-U201 module. For HSDPA category 8, 2-band 3G 850/1900 (North America), Digital Audio Interfaces support, select a suitable LISA-U260 module. For HSDPA category 8, 2-band 3G 900/2100 (Europe, Asia, Middle-East and Africa), Digital Audio Interfaces support, select a suitable LISA-U270 module. Check LISA-U2 series Hardware Requirements Check the supported 3G bands for proper antenna circuit development, since LISA-U2 supports different 3G bands in comparison to LISA-U1 series cellular modules. Check audio requirements, since Analog Audio Interfaces are not supported by LISA-U2 series. Check audio requirements, since Digital Audio Interfaces are supported by LISA-U2 series modules. Check the PWR_ON low pulse time specified to switch-on the module, since PWR_ON low pulse time requirement is different in comparison to LISA-U1 series modules. Check the PWR_ON behavior, since LISA-U2 series modules can be switched off forcing PWR_ON pin to the low level for at least 1 s. Check the PWR_ON input voltage thresholds, since they are slightly changed in comparison to LISA-U1 series modules. By the way, this is not relevant driving the PWR_ON input by an open drain or open collector driver as recommended. Check the RESET_N input voltage thresholds, since they are slightly changed in comparison to LISA-U1 series modules. By the way, this is not relevant driving the RESET_N input by an open drain or open collector driver as recommended. Check the V_BCKP operating characteristics, since they are slightly changed in comparison to LISA-U1 series modules. Check internal active pull-up / down values at digital interface input pins and the current capability of digital interface output pins, since they are slightly changed in comparison to LISA-U1 series modules. Check board layout, since additional signals keep-out area must be implemented on the top layer of the application board, below LISA-U2 modules, due to GND opening on module bottom layer. A.2 Software migration A.2.1 Software migration from LISA-U1 series to LISA-U2 series modules Software migration from LISA-U1 to LISA-U2 series cellular modules is a straightforward procedure. Nevertheless there are some differences to be considered with firmware version. Like predecessors, LISA-U2 series cellular module supports AT commands according to 3GPP standards: TS 27.007 [4], TS 27.005 [5], TS 27.010 [6] and the u-blox AT command extension. Backward compatibility has been maintained as far as possible. For the complete list of supported AT commands and their syntax see u-blox AT Commands Manual [2]. UBX-13001118 - R19 Early Production Information Appendix Page 161 of 175 LISA-U2 series - System Integration Manual A.3 Hardware migration A.3.1 Hardware migration from LISA-U1 series to LISA-U2 series modules LISA-U2 series modules have been designed with backward compatibility in mind but some minor differences were unavoidable. These minor differences will however not be relevant for the majority of the LISA-U1 series designs. Clean and stable supply is required by LISA-U2 as by LISA-U1 series: low ripple and low voltage drop must be guaranteed at VCC pins. The voltage provided has to be within the normal operating range limits to allow module switch-on and has to be above the minimum limit of the extended operating range to avoid module switch-off. Consider that there are large current spikes in connected mode, when a GSM call is enabled. LISA-U2 series provide wider VCC input voltage range compared to LISA-U1 series. The ANT pin has 50 Ω nominal characteristic impedance and must be connected to the antenna through a 50 Ω transmission line to allow transmission and reception of radio frequency (RF) signals in the 2G and 3G operating bands. The recommendations of the antenna producer for correct installation and deployment (PCB layout and matching circuitry) must be followed. The antenna and the whole RF circuit must provide optimal radiating characteristics on the entire supported bands: note that LISA-U2 supports different 3G bands in comparison to LISA-U1 series modules. An external application circuit can be implemented on the application device integrating LISA-U2 series modules to satisfy ESD immunity test requirements at the antenna interface, as described in Figure 68 and Table 53 in section 2.5.3. The same application circuit is not applicable for LISA-U1 series. LISA-U230 modules provide the RF antenna input for Rx diversity on the pin 74 (named ANT_DIV): it has an impedance of 50 Ω. The same pad is a reserved pin on LISA-U1 series and on the other LISA-U2 series modules. Analog audio interfaces are not supported by LISA-U2 series modules, but a second 4-wire I S digital audio interface is provided instead of the 4 analog audio pins. The same 4 pins can be configured as GPIO on LISA-U2 series modules. Analog audio can be provided with an external audio codec connected to LISA-U2 series modules, implementing the application circuit described in Figure 50. An external audio codec can be connected to the I S digital audio interface of LISA-U1 series modules as shown in the same application circuit described in Figure 50. In this case the application processor should properly control the audio codec by I C interface and should properly provide clock reference to the audio codec. This circuit allows migration from LISA-U1 series to LISA-U2 series, providing analog audio with the same application circuit. PWR_ON low pulse time required to switch-on the module is different in comparison to LISA-U1 series modules. LISA-U2 series can be switched off forcing PWR_ON pin to the low level for at least 1 s. PWR_ON and RESET_N input voltage thresholds are slightly changed in comparison to LISA-U1 series modules, but this is not relevant driving PWR_ON and RESET_N inputs by open drain / collector drivers as recommended. V_BCKP operating characteristics are slightly changed in comparison to LISA-U1 series modules. The voltage level of all the digital interfaces of LISA-U2 series modules is 1.8 V as for LISA-U1 series modules. The internal active pull-up / pull-down values at digital interface input pins and the current capability of digital interface output pins LISA-U2 series modules are slightly changed in comparison to LISA-U1 series modules. UART of LISA-U2 series supports autobauding (default setting) and 921600 b/s baud rate. LISA-U2 series provide one additional USB CDC for remote SIM Access Profile (SAP). UBX-13001118 - R19 Early Production Information Appendix Page 162 of 175 LISA-U2 series - System Integration Manual The 5 pins of the SPI / IPC Serial Interface can be configured as GPIOs on LISA-U2 series. The DDC (I C) interface of LISA-U2 series modules can be used to communicate with u-blox GNSS receivers and at the same time to control an external audio codec. The LISA-U2 series module acts as an I C master which can communicate to two I C slaves as allowed by I C bus specifications [8]. LISA-U2 modules provide additional GPIO functions: Module Status and Operating Mode Indications. LISA-U2 modules are SMT modules and share the same compact form factor as the LISA-U1 series, featuring Leadless Chip Carrier (LCC) packaging technology. An additional signal keep-out area must be implemented on the top layer of the application board, below LISA-U2 modules, due to the GND opening on module bottom layer. Detailed pinout and layout comparisons between LISA-U1 series and LISA-U2 series modules, with remarks for migration, are provided in the subsections A.3.2 and A.3.3. For more information about the electrical characteristics of the LISA-U1 and LISA-U2 series modules, see the LISA-U1 series Data Sheet [29] and LISA-U2 series Data Sheet [1]. A.3.2 Pin-out comparison LISA-U1 series vs. LISA-U2 series Rx Div ANT 68 GND 66 GND 67 GND 69 GND 70 GND 73 GND 71 GND 72 RSVD / ANT_DIV 74 GND 76 GND 75 ANT 68 GND 66 GND 67 GND 69 GND 70 GND 73 GND 71 GND 72 GND 75 RSVD 74 GND 76 RSVD GND 65 GND GND 64 V_BCKP VCC 63 GND V_INT VCC 62 V_INT RSVD VCC 61 RSVD GND GND 60 GND GND 60 GND SPI_MRDY 59 GND SPI_MRDY / GPIO14 59 GND SPI_SRDY 58 GND SPI_SRDY / GPIO13 58 GND V_BCKP GND SPI GND 65 GND 64 VCC 63 VCC 62 VCC 61 DSR SPI_MISO 57 DSR SPI_MISO / GPIO12 57 10 RI SPI_MOSI 56 10 RI SPI_MOSI / GPIO11 56 11 DCD SPI_SCLK 55 11 DCD SPI_SCLK / GPIO10 55 12 DTR RSVD / SPK_N 54 12 DTR 13 RTS RSVD / SPK_P 53 13 RTS 14 CTS 15 TXD 16 17 18 VUSB_DET 19 PWR_ON 20 GPIO1 21 GPIO2 22 RESET_N 23 24 25 26 USB_D- 27 USB_D+ LISA-U1 RSVD GPIO9 / I2S1_WA 54 LISA-U2 GPIO8 / I2S1_CLK 53 14 CTS GPIO5 51 15 TXD RXD VSIM 50 16 RXD VSIM 50 GND SIM_RST 49 17 GND SIM_RST 49 18 VUSB_DET 19 PWR_ON 20 GPIO1 RSVD 52 Top View SIM_IO 48 SIM_CLK 47 SDA 46 Analog Audio Top View RSVD / CODEC_CLK 52 GPIO5 51 SIM_IO 48 SIM_CLK 47 SDA 46 SCL 45 21 GPIO2 RSVD / I2S_RXD 44 22 RESET_N GPIO3 RSVD / I2S_CLK 43 23 GPIO3 RSVD / I2S_CLK 43 GPIO4 RSVD / I2S_TXD 42 24 GPIO4 RSVD / I2S_TXD 42 GND RSVD / I2S_WA 41 25 GND RSVD / MIC_P 40 26 USB_D- RSVD / MIC_N 39 27 USB_D+ Figure 77: LISA-U1 series pin assignment UBX-13001118 - R19 RSVD / I2S_RXD 44 Clock Out Digital Audio or GPIO RSVD / I2S_WA 41 GPIO7 / I2S1_TXD 40 38 36 35 34 33 32 31 30 29 37 GPIO6 / I2S1_RXD 39 Pin 28…38 = GND 28 37 36 35 34 33 32 31 30 29 28 Pin 28…38 = GND 38 SCL 45 SPI or GPIO Figure 78: LISA-U2 series pin assignment (highlighted name/function changes) Early Production Information Appendix Page 163 of 175 LISA-U2 series - System Integration Manual LISA-U1 series LISA-U2 series No Name Description Name Description GND Ground GND Ground V_BCKP RTC supply input/output V_BCKP RTC supply input/output GND V_INT Ground Digital Interfaces supply output GND V_INT Ground Digital Interfaces supply output RSVD RESERVED pin RSVD RESERVED pin … GND Ground GND Ground DSR UART data set ready output DSR UART data set ready output Circuit 107 (DSR) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 1 mA 10 RI UART ring indicator output RI UART ring indicator output 11 DCD UART data carrier detect output DCD UART data carrier detect output 12 DTR UART data terminal ready input DTR UART data terminal ready input 13 RTS UART ready to send input RTS UART ready to send input 14 CTS UART clear to send output CTS UART clear to send output Circuit 125 (RI) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 2 mA Circuit 109 (DCD) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 2 mA Circuit 108/2 (DTR) in ITU-T V. 24, 1.8V typ. LISA-U1 series: o Internal active pull-up = -110 µA LISA-U2 series: o Internal active pull-up = -125 µA Circuit 105 (RTS) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Internal active pull-up = -60 µA LISA-U2 series: o Internal active pull-up = -240 µA Circuit 106 (CTS) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 6 mA 15 TXD UART transmitted data input TXD UART transmitted data input Circuit 103 (TxD) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Internal active pull-up = -60 µA LISA-U2 series: o Internal active pull-up = -240 µA 16 RXD UART received data output RXD UART received data output Circuit 104 (RxD) in ITU-T V.24, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 6 mA 17 GND Ground GND Ground 18 VUSB_DET USB detect input VUSB_DET USB detect input UBX-13001118 - R19 Early Production Information Remarks for Migration V_BCKP operating characteristics difference: LISA-U1 series: o V_BCKP output = 2.3V typ. o V_BCKP input = 1.0V min / 2.5V max LISA-U2 series: o V_BCKP output = 1.8V typ. o V_BCKP input = 1.0V min / 1.9V max No difference: V_INT output = 1.8V typ., 70 mA max. No difference: This pin must be connected to GND No difference Appendix Page 164 of 175 LISA-U2 series - System Integration Manual LISA-U1 series LISA-U2 series No Name Description Name Description Remarks for Migration 19 PWR_ON Power-on input PWR_ON Power-on input 20 GPIO1 GPIO GPIO1 GPIO PWR_ON switch-on low pulse time difference: LISA-U1 series: o L-level pulse time = 5 ms min LISA-U2 series: o L-level pulse time = 50 µs min / 80 µs max PWR_ON switch-off low pulse time difference: LISA-U1 series: o Switch-off by PWR_ON not supported LISA-U2 series: o L-level pulse time = 1 s min PWR_ON operating voltage difference: LISA-U1 series: o L-level input = -0.30 V min / 0.65 V max o H-level input = 2.00 V min / 4.20 V max o External pull-up (e.g. to V_BCKP) required LISA-U2 series: o L-level input = -0.30 V min / 0.65 V max o H-level input = 1.50 V min / 4.40 V max o External pull-up (e.g. to V_BCKP) required Configurable GPIO, 1.8V typ. LISA-U1 series: o Output driver strength = 1 mA LISA-U2 series: o Output driver strength = 6 mA Functions on all LISA-U series: o Pad disabled (default) o Input / Output o Network Status Indication o GNSS Supply Enable o GSM Tx Burst Indication Function on LISA-U2 series: o Module Status Indication 21 GPIO2 GPIO GPIO2 GPIO 22 RESET_N External reset input RESET_N External reset input UBX-13001118 - R19 Early Production Information Configurable GPIO, 1.8V typ. LISA-U1 series: o Output driver strength = 1 mA LISA-U2 series: o Output driver strength = 1 mA Functions on all LISA-U series: o Pad disabled o Input / Output o Network Status Indication o GNSS Supply Enable (default) RESET_N hardware reset or switch-on low pulse time: LISA-U1 series: o L-level pulse time = 50 ms min LISA-U2 series: o L-level pulse time = 50 ms min RESET_N operating voltage difference: LISA-U1 series: o L-level input = -0.30 V min / 0.65 V max o H-level input = 1.69 V min / 2.48 V max o Internal 10kΩ pull-up to V_BCKP (2.3V typ) LISA-U2 series: o L-level input = -0.30 V min / 0.51 V max o H-level input = 1.32 V min / 2.01 V max o Internal 10 kΩ pull-up to V_BCKP (1.8V typ) Appendix Page 165 of 175 LISA-U2 series - System Integration Manual LISA-U1 series LISA-U2 series No Name Description Name Description Remarks for Migration 23 GPIO3 GPIO GPIO3 GPIO Configurable GPIO, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 6 mA Functions on all LISA-U series: o Pad disabled o Input / Output o Network Status Indication o GNSS Supply Enable o GNSS Data Ready (default) 24 GPIO4 GPIO GPIO4 GPIO Configurable GPIO, 1.8V typ. LISA-U1 series: o Output driver strength = 4 mA LISA-U2 series: o Output driver strength = 6 mA Functions on all LISA-U series: o Pad disabled o Input / Output o Network Status Indication o GNSS Supply Enable o GNSS RTC Sharing (default) 25 26 GND USB_D- GND USB_D- 27 USB_D+ 28 ... 38 39 GND Ground USB Data Line Dinput/output USB Data Line D+ input/output Ground Ground USB Data Line Dinput/output USB Data Line D+ input/output Ground MIC_N LISA-U120, LISA-U130: Differential analog audio input (neg.) LISA-U100, LISA-U110: RESERVED pin I2S1_RXD / GPIO6 LISA-U2 series, 2nd I2S Rx data input / GPIO 40 MIC_P LISA-U120, LISA-U130: Differential analog audio input (pos.) LISA-U100, LISA-U110: RESERVED pin I2S1_TXD / GPIO7 LISA-U2 series: 2nd I2S Tx data output GPIO 41 I2S_WA LISA-U120, LISA-U130: I2S word alignment LISA-U100, LISA-U110: RESERVED pin I2S_WA LISA-U2 series: 1st I2S word alignment input/output UBX-13001118 - R19 USB_D+ GND Early Production Information No difference No difference LISA-U120, LISA-U130: Differential analog audio input (neg.) LISA-U2 series: I2S1_RXD and configurable GPIO, 1.8V typ. o Output driver strength = 1 mA o Internal active pull-down = 150 µA Functions: o I2S1_RXD (default) o Pad disabled o Input / Output LISA-U120, LISA-U130: Differential analog audio input (pos.) LISA-U2 series: I2S1_TXD and configurable GPIO, 1.8V typ. o Output driver strength = 1 mA Functions: o I2S1_TXD (default) o Pad disabled o Input / Output I2S_WA, 1.8V typ. LISA-U120, LISA-U130: o Output driver strength = 2.5 mA o Internal active pull-down = 100 µA LISA-U2 series: o Output driver strength = 2 mA o Internal active pull-down = 200 µA Appendix Page 166 of 175 LISA-U2 series - System Integration Manual LISA-U1 series LISA-U2 series No Name Description Name Description Remarks for Migration 42 I2S_TXD LISA-U120, LISA-U130: I2S Tx data output LISA-U100, LISA-U110: RESERVED pin I2S_TXD LISA-U2 series: 1st I2S Tx data output I2S_TXD, 1.8V typ. LISA-U120, LISA-U130: o Output driver strength = 2.5 mA LISA-U2 series: o Output driver strength = 2 mA 43 I2S_CLK LISA-U120, LISA-U130: I2S clock LISA-U100, LISA-U110: RESERVED pin I2S_CLK LISA-U2 series: 1st I2S clock input/output I2S_CLK, 1.8V typ. LISA-U120, LISA-U130: o Output driver strength = 2.5 mA o Internal active pull-down = 100 µA LISA-U2 series: o Output driver strength = 2 mA o Internal active pull-down = 200 µA 44 I2S_RXD LISA-U120, LISA-U130: I2S Rx data input LISA-U100, LISA-U110: RESERVED pin I2S_RXD LISA-U2 series: 1st I2S Rx data input I2S_RXD, 1.8V typ. LISA-U120, LISA-U130: o Output driver strength = 2.5 mA o Internal active pull-down = 100 µA LISA-U2 series: o Output driver strength = 2 mA o Internal active pull-down = 200 µA 45 SCL I2C bus clock line output SCL I2C bus clock line output LISA-U1 series: I2C SCL for GNSS, 1.8V typ. o Fixed open drain o External pull-up (e.g. to V_INT) required LISA-U2 series: I2C SCL for GNSS and other I2C devices, 1.8V typ. o Fixed open drain o External pull-up (e.g. to V_INT) required 46 SDA I2C bus data line input/output SDA I2C bus data line input/output LISA-U1 series: I2C SDA for GNSS, 1.8V typ. o Fixed open drain o External pull-up (e.g. to V_INT) required LISA-U2 series: I2C SDA for GNSS and other I2C devices, 1.8V typ o Fixed open drain o External pull-up (e.g. to V_INT) required 47 SIM_CLK SIM clock output SIM_CLK SIM clock output 48 SIM_IO SIM data input/output SIM_IO SIM data input/output 49 SIM_RST SIM reset output SIM_RST SIM reset output No difference: 3.25 MHz clock frequency for SIM card No difference: Internal 4.7 kΩ pull-up resistor to VSIM. No difference: Reset output for SIM card 50 VSIM SIM supply output VSIM SIM supply output 51 GPIO5 GPIO GPIO5 GPIO UBX-13001118 - R19 Early Production Information No difference: VSIM output = 1.80 V typ or 2.90 V typ Configurable GPIO, 1.8V typ. LISA-U1 series: o Output driver strength = 2.5 mA LISA-U2 series: o Output driver strength = 6 mA Functions on all LISA-U series: o Pad disabled o Input / Output o SIM card detection (default) o Network Status Indication o GNSS Supply Enable Functions on LISA-U2 series only: o Module Operating Mode Indication o SIM card hot insertion/removal (+UDCONF) Appendix Page 167 of 175 LISA-U2 series - System Integration Manual LISA-U1 series LISA-U2 series No Name Description Name Description Remarks for Migration 52 RSVD RESERVED pin CODEC_CLK LISA-U2 series: Clock output 53 SPK_P LISA-U120, LISA-U130: Differential analog audio output (pos.) LISA-U100, LISA-U110: RESERVED pin I2S1_CLK / GPIO8 LISA-U2 series: 2nd I2S clock input/output / GPIO 54 SPK_N LISA-U120, LISA-U130: Differential analog audio output (neg.) LISA-U100, LISA-U110: RESERVED pin I2S1_WA / GPIO9 LISA-U2 series: 2nd I2S word alignment input/output / GPIO 55 SPI_SCLK SPI Serial Clock Input SPI_SCLK / GPIO10 SPI Serial Clock Input / GPIO LISA-U2 series: Digital clock output for external audio codec Output driver strength = 4 mA LISA-U120, LISA-U130: Differential analog audio output (pos.) LISA-U2 series: I2S1_CLK and configurable GPIO, 1.8V typ. o Output driver strength = 1 mA o Internal active pull-down = 150 µA Functions: o I2S1_CLK (default) o Pad disabled o Input / Output LISA-U120, LISA-U130: Differential analog audio output (neg.) LISA-U2 series: I2S1_WA and configurable GPIO, 1.8V typ. o Output driver strength = 1 mA o Internal active pull-down = 150 µA Functions: o I2S1_WA (default) o Pad disabled o Input / Output LISA-U1 series: SPI_CLK, 1.8V typ o Internal active pull-down = 100 µA LISA-U2 series: SPI_CLK and configurable GPIO, 1.8V typ. o Internal active pull-down = 200 µA o Output driver strength = 6 mA Functions: o SPI_CLK (default) o Pad disabled o Input / Output 56 SPI_MOSI SPI Data Line Input SPI_MOSI / GPIO11 SPI Data Line Input / GPIO 57 SPI_MISO SPI Data Line Output SPI_MISO / GPIO12 SPI Data Line Output / GPIO UBX-13001118 - R19 Early Production Information LISA-U1 series: SPI_MOSI, 1.8V typ o Internal active pull-up = -110 µA LISA-U2 series: SPI_MOSI and configurable GPIO, 1.8V typ. o Internal active pull-up = -240 µA o Output driver strength = 6 mA Functions: o SPI_MOSI (default) o Pad disabled o Input / Output LISA-U1 series: SPI_MISO, 1.8V typ o Output driver strength = 2.5 mA LISA-U2 series: SPI_MISO and configurable GPIO, 1.8V typ. o Output driver strength = 6 mA Functions: o SPI_MISO (default) o Pad disabled o Input / Output Appendix Page 168 of 175 LISA-U2 series - System Integration Manual LISA-U1 series LISA-U2 series No Name Description Name Description Remarks for Migration 58 SPI_SRDY SPI Slave Ready Output SPI_SRDY / GPIO13 SPI Slave Ready Output / GPIO LISA-U1 series: SPI_SRDY, 1.8V typ o Output driver strength = 4 mA LISA-U2 series: SPI_SRDY and configurable GPIO, 1.8V typ. o Output driver strength = 6 mA Functions: o SPI_SRDY (default) o Pad disabled o Input / Output o Module Status Indication 59 SPI_MRDY SPI Master Ready Input SPI_MRDY / GPIO14 SPI Master Ready Input / GPIO LISA-U1 series: SPI_MRDY, 1.8V typ o Internal active pull-down = 55 µA LISA-U2 series: SPI_MRDY and configurable GPIO, 1.8V typ. o Internal active pull-down = 200 µA o Output driver strength = 6 mA Functions: o SPI_MRDY (default) o Pad disabled o Input / Output o Module Operating Mode Indication 60 GND Ground GND Ground 61 … 63 VCC Module supply input VCC Module supply input 64 … 67 GND Ground GND Ground 68 ANT RF antenna ANT RF input/output for main Tx/Rx antenna 69 … 73 74 GND Ground GND Ground RSVD RESERVED pin RSVD All except LISA-U230: RESERVED pin ANT_DIV LISA-U230: RF input for Rx diversity antenna GND GND Ground Ground 75 76 GND GND Ground Ground VCC operating voltage difference: LISA-U1 series: o VCC normal range = 3.4 V min / 4.2 V max o VCC extended range = 3.1 V min / 4.2 V max LISA-U2 series: o VCC normal range = 3.3 V min / 4.4 V max o VCC extended range = 3.1 V min / 4.5 V max 3G band support difference: LISA-U100, LISA-U120, LISA-U260: o Band II (1900), Band V (850) LISA-U110, LISA-U130, LISA-U270: o Band I (2100), Band VIII (900) LISA-U200-00S: o Band I (2100), Band II (1900), Band V (850), Band VI (800) All LISA-U2 series except LISA-U200-00S: o Band I (2100), Band II (1900), Band IV (1700), Band V (850), Band VI (800), Band VIII (900) LISA-U1 series and all LISA-U2 series except LISA-U230: RESERVED pin o Leave unconnected LISA-U230: RF antenna input for Rx diversity o 50 Ω nominal impedance Table 61: Pinout comparison LISA-U1 series vs. LISA-U2 series UBX-13001118 - R19 Early Production Information Appendix Page 169 of 175 LISA-U2 series - System Integration Manual A.3.3 Layout comparison LISA-U1 series vs. LISA-U2 series Additional signals keep-out area must be implemented on the top layer of the application board, below LISA-U2 modules, due to GND opening on module bottom layer, as described in Figure 79 and Figure 80. 11.85 mm 5.3 mm 5.25 mm 1.4 mm 1.0 mm PIN 1 Exposed GND on LISA-U1 module bottom layer Signals keep-out area on application board 33.2 mm LISA-U1 bottom side (through module view) 22.4 mm Figure 79: Signals keep-out area on the top layer of the application board, below LISA-U1 series modules 1.3 mm 5.25 mm 5.3 mm 5.3 mm 5.25 mm 1.4 mm 1.0 mm PIN 1 Exposed GND on LISA-U2 module bottom layer Signals keep-out areas on application board 33.2 mm LISA-U2 bottom side (through module view) 22.4 mm Figure 80: Signals keep-out areas on the top layer of the application board, below LISA-U2 series modules UBX-13001118 - R19 Early Production Information Appendix Page 170 of 175 LISA-U2 series - System Integration Manual B Glossary ADC Analog to Digital Converter AP Application Processor AT AT Command Interpreter Software Subsystem, or attention CBCH Cell Broadcast Channel CS Coding Scheme CSD Circuit Switched Data CTS Clear To Send DC Direct Current DCD Data Carrier Detect DCE Data Communication Equipment DCS Digital Cellular System DDC Display Data Channel DSP Digital Signal Processing DSR Data Set Ready DTE Data Terminal Equipment DTM Dual Transfer Mode DTR Data Terminal Ready EBU External Bus Interface Unit EDGE Enhanced Data rates for GSM Evolution E-GPRS Enhanced GPRS FDD Frequency Division Duplex FEM Front End Module FOAT Firmware Over AT commands FTP File Transfer Protocol FTPS FTP Secure GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPRS General Packet Radio Service GPS Global Positioning System GSM Global System for Mobile Communication HF Hands-free HSDPA High Speed Downlink Packet Access HTTP HyperText Transfer Protocol HTTPS Hypertext Transfer Protocol over Secure Socket Layer HW Hardware I/Q In phase and Quadrature Inter-Integrated Circuit IS Inter IC Sound IP Internet Protocol IC UBX-13001118 - R19 Early Production Information Appendix Page 171 of 175 LISA-U2 series - System Integration Manual IPC Inter Processor Communication LNA Low Noise Amplifier MCS Modulation Coding Scheme NOM Network Operating Mode PA Power Amplifier PBCCH Packet Broadcast Control Channel PCM Pulse Code Modulation PCS Personal Communications Service PFM Pulse Frequency Modulation PMU Power Management Unit RF Radio Frequency RI Ring Indicator RTC Real Time Clock RTS Request To Send RXD RX Data SAW Surface Acoustic Wave SIM Subscriber Identification Module SMS Short Message Service SMTP Simple Mail Transfer Protocol SPI Serial Peripheral Interface SRAM Static RAM TCP Transmission Control Protocol TDMA Time Division Multiple Access TXD TX Data UART Universal Asynchronous Receiver-Transmitter UDP User Datagram Protocol UMTS Universal Mobile Telecommunications System USB Universal Serial Bus UTRA UMTS Terrestrial Radio Access VC-TCXO Voltage Controlled - Temperature Compensated Crystal Oscillator WCDMA Wideband CODE Division Multiple Access UBX-13001118 - R19 Early Production Information Appendix Page 172 of 175 LISA-U2 series - System Integration Manual Related documents [1] u-blox LISA-U2 series Data Sheet, Docu No UBX-13001734 [2] u-blox AT Commands Manual, Docu No UBX-13002752 [3] ITU-T Recommendation V.24, 02-2000. List of definitions for interchange circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE). http://www.itu.int/rec/T-REC-V.24-200002-I/en [4] 3GPP TS 27.007 - AT command set for User Equipment (UE) (Release 1999) [5] 3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating; Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) (Release 1999) [6] 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol (Release 1999) [7] Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/ [8] I2C-Bus specification and user manual - Rev. 5 - 9 October 2012 - NXP Semiconductors, http://www.nxp.com/documents/user_manual/UM10204.pdf [9] 3GPP TS 51.010-2 - Technical Specification Group GSM/EDGE Radio Access Network; Mobile Station (MS) conformance specification; Part 2: Protocol Implementation Conformance Statement (PICS) [10] 3GPP TS 34.121-2 - Technical Specification Group Radio Access Network; User Equipment (UE) conformance specification; Radio transmission and reception (FDD); Part 2: Implementation Conformance Statement (ICS) [11] CENELEC EN 61000-4-2 (2001): "Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test". [12] ETSI EN 301 489-1 V1.8.1: “Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements” [13] ETSI EN 301 489-7 V1.3.1: “Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS)“ [14] ETSI EN 301 489-24 V1.4.1: "Electromagnetic compatibility and Radio spectrum Matters (ERM); Electro-Magnetic Compatibility (EMC) standard for radio equipment and services; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread (UTRA) for Mobile and portable (UE) radio and ancillary equipment" [15] u-blox Multiplexer Implementation Application Note, Docu No UBX-13001887 [16] u-blox GNSS Implementation Application Note, Docu No UBX-13001849 [17] u-blox Firmware Update Application Note, Docu No UBX-13001845 [18] u-blox SPI Interface Application Note, Docu No UBX-13001919 [19] 3GPP TS 23.060 - Technical Specification Group Services and System Aspects; General Packet Radio Service (GPRS); Service description [20] u-blox End user test Application Note, Docu No WLS-CS-12002 [21] u-blox Package Information Guide, Docu No GPS-X-11004 [22] SIM Access Profile Interoperability Specification, Revision V11r00, http://www.bluetooth.org [23] u-blox LISA-U1 / LISA-U2 Audio Application Note, Docu No UBX-13001835 [24] 3GPP TS 26.267 V10.0.0 – eCall Data Transfer; In-band modem solution; General description (Rel. 10) [25] BS EN 16062:2011 – Intelligent transport systems – eSafety – eCall high level application requirements [26] ETSI TS 122 101 V8.7.0 – Service aspects; Service principles (3GPP TS 22.101 v.8.7.0 Rel. 8) [27] 3GPP TS 44.031 Location Services (LCS); Mobile Station (MS) - Serving Mobile Location Centre (SMLC) Radio Resource LCS Protocol (RRLP) [28] 3GPP TS 25.331 Radio Resource Control (RRC); Protocol specification [29] u-blox LISA-U1 series Data Sheet, Docu No UBX-13002048 Some of the above documents can be downloaded from u-blox web-site (http://www.u-blox.com). UBX-13001118 - R19 Early Production Information Related documents Page 173 of 175 LISA-U2 series - System Integration Manual Revision history Revision Date Name Status / Comments 21-Oct-2010 sses Initial Release 11-Jan-2011 sses Thickness information added. GPIO description improved 26-Apr-2011 lpah Update to Advance Information status 07-Jul-2011 lpah Update to Preliminary status 26-Oct-2011 sses Changed status to Objective Specification Initial release for LISA-U series: From LISA-U1x0-00S system integration manual, added the description and the integration of LISA-U1x0-01S, LISA-U200-00S, LISA-U2x0-01S Added notes regarding VCC normal and extended operating ranges. Added RTC value reliability as function of V_BCKP voltage value. Added recommendation regarding any external signal connected to the UART interface, SPI/IPC interface, I2S interfaces and GPIOs when the module is in power-down mode, when the external reset is forced low and during the module power-on sequence: must be tri-stated to avoid latch-up of circuits and let a proper boot of the module. A1 22-Nov-2011 sses Update to Advance Information status Updated module behavior during power-off sequence. Added LISA-U200-00S ESD application circuit for antenna port. Added application circuit for the module status indication function. A2 02-Feb-2012 sses Update to Preliminary status Updated Federal Communications Commission notice. Updated LISA-U2 features in module power off and GPIO sections A3 25-May-2012 gcom Updated values for antenna gain A4 20-Jun-2012 sses Update to Advance Information status Updated PWR_ON behavior. Updated UART and power saving behavior. Added 3V / 1.8V SPI application circuit. Updated GPS RTC sharing application circuit. Added remote SIM access profile description A5 24-Aug-2012 sses Update to Preliminary status Updated Federal Communications Commission notice. Updated recommended VCC bypass capacitors. Added LISA-U110-60S and LISA-U130-60S A6 04-Oct-2012 lpah / sses A7 26-Nov-2012 lpah / sses Update to Advance Information status Added LISA-U260 and LISA-U270 Update to Preliminary status Removed document applicability to LISA-U1x0-00S versions Added document applicability to LISA-U110-50S versions A8 29-Mar-2013 sses 15-Jul-2013 sses Updated additional recommendations for VCC application circuits (Last revision with old doc number, 3G.G2-HW-10002) Update status to Advance Information First release for LISA-U200-02S, LISA-U200-61S, LISA-U200-62S, LISA-U260-02S, LISA-U27002S, LISA-U270-62S B1 21-Aug-2013 lpah Update status to Preliminary R16 20-Mar-2014 lpah / sses Extended document applicability to LISA-U200-52S and LISA-U200-82S (LISA-U200 FOTA) Updated recommended I2C voltage translator and clarified I2C application circuits remarks Clarified and improved power-on, power-off and reset timings and procedures descriptions R17 26-Jun-2015 sfal Extended document applicability to LISA-U200-03S and LISA-U201-03S R18 10-Aug-2015 sfal Early Production Information status Removed LISA-U1 series modules and LISA-U200-00S Extended applicability to LISA-U200-83S and LISA-U270-68S UBX-13001118 - R19 Early Production Information Revision history Page 174 of 175 Comment [smos1]: I would remove this to make space on the page for further revision history. This is old and very detailed, so unnecessary. LISA-U2 series - System Integration Manual Contact For complete contact information visit us at www.u-blox.com u-blox Offices North, Central and South America u-blox America, Inc. Phone: E-mail: +1 703 483 3180 info_us@u-blox.com Regional Office West Coast: Phone: +1 408 573 3640 E-mail: info_us@u-blox.com Headquarters Europe, Middle East, Africa Asia, Australia, Pacific u-blox AG Phone: E-mail: Support: Phone: E-mail: Support: +41 44 722 74 44 info@u-blox.com support@u-blox.com Technical Support: Phone: +1 703 483 3185 E-mail: support_us@u-blox.com u-blox Singapore Pte. Ltd. +65 6734 3811 info_ap@u-blox.com support_ap@u-blox.com Regional Office Australia: Phone: +61 2 8448 2016 E-mail: info_anz@u-blox.com Support: support_ap@u-blox.com Regional Office China (Beijing): Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Chongqing): Phone: +86 23 6815 1588 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shanghai): Phone: +86 21 6090 4832 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shenzhen): Phone: +86 755 8627 1083 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office India: Phone: E-mail: Support: +91 959 1302 450 info_in@u-blox.com support_in@u-blox.com Regional Office Japan (Osaka): Phone: +81 6 6941 3660 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Japan (Tokyo): Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: +82 2 542 0861 E-mail: info_kr@u-blox.com Support: support_kr@u-blox.com Regional Office Taiwan: Phone: E-mail: Support: UBX-13001118 - R19 Early Production Information +886 2 2657 1090 info_tw@u-blox.com support_tw@u-blox.com Contact Page 175 of 175
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 175 Language : it-IT Tagged PDF : Yes Title : LISA-U2 series Subject : System Integration Manual Creator : Microsoft® Office Word 2007 Create Date : 2015:09:09 16:34:17+02:00 Modify Date : 2015:09:09 16:34:17+02:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools