u blox TOBYL201 UMTS/LTE Data Module User Manual TOBY L2 series
u-blox AG UMTS/LTE Data Module TOBY L2 series
u blox >
Contents
Datasheet
TOBY-L2 series LTE/DC-HSPA+/EGPRS modules Data Sheet Abstract Technical data sheet describing TOBY-L2 series multi-mode cellular modules. The modules are a complete and cost efficient LTE/3G/2G multi-mode solution offering up to 150 Mb/s download data rate and up to 50 Mb/s upload data rate, covering up to six LTE bands, up to five WCDMA/DC-HSPA+ bands and four GSM/EGPRS bands in the compact TOBY form factor. www.u-blox.com UBX-13004573 - R07 TOBY-L2 series - Data Sheet Document Information Title TOBY-L2 series Subtitle LTE/DC-HSPA+/EGPRS modules Document type Data Sheet Document number UBX-13004573 Revision and date R07 Document status Objective Specification 08-Apr-2015 Document status explanation Objective Specification Document contains target values. Revised and supplementary data will be published later. Advance Information Document contains data based on early testing. Revised and supplementary data will be published later. Early Production Information Document contains data from product verification. Revised and supplementary data may be published later. Production Information Document contains the final product specification. This document applies to the following products: Name Type number Modem version Application version PCN / IN TOBY-L200 TOBY-L200-00S-00 09.71 A01.15 UBX-14044437 TOBY-L200-50S-00 09.71 A01.57 UBX-15004131 TOBY-L201 TOBY-L210 TOBY-L201-01S-00 TOBY-L210-00S-00 09.78 09.71 A01.00 A01.15 TBD UBX-14044437 TOBY-L280 TOBY-L210-50S-00 TOBY-L280-00S-00 09.71 TBD A01.57 TBD UBX-15004131 TBD u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of u-blox is strictly prohibited. The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, please visit www.u-blox.com. Copyright © 2015, u-blox AG. u-blox® is a registered trademark of u-blox Holding AG in the EU and other countries. Trademark Notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective owners. UBX-13004573 - R07 Page 2 of 47 TOBY-L2 series - Data Sheet Contents Contents.............................................................................................................................. 3 Functional description.................................................................................................. 5 1.1 1.2 Overview .............................................................................................................................................. 5 Product features ................................................................................................................................... 5 1.3 Block diagram....................................................................................................................................... 6 1.4 1.5 Product description ............................................................................................................................... 7 AT command support ........................................................................................................................... 8 1.6 Supported features ............................................................................................................................... 9 Interfaces .................................................................................................................... 11 2.1 Power management ........................................................................................................................... 11 2.1.1 Module supply input (VCC) ......................................................................................................... 11 2.1.2 2.1.3 RTC supply input / output (V_BCKP) ............................................................................................ 11 Generic digital interfaces supply output (V_INT) ........................................................................... 11 2.2 Antenna interfaces ............................................................................................................................. 11 2.2.1 2.2.2 2.3 Antenna RF interfaces ................................................................................................................. 11 Antenna detection ...................................................................................................................... 11 System functions ................................................................................................................................ 11 2.3.1 2.3.2 Module power-on ....................................................................................................................... 11 Module power-off ....................................................................................................................... 12 2.3.3 Module reset ............................................................................................................................... 12 2.3.4 Module configuration selection by host processor ....................................................................... 12 2.4 SIM ..................................................................................................................................................... 13 2.4.1 SIM interface ............................................................................................................................... 13 2.4.2 SIM detection .............................................................................................................................. 13 2.5 Serial communication ......................................................................................................................... 13 2.5.1 UART interface ............................................................................................................................ 13 2.5.2 2.5.3 USB interface............................................................................................................................... 15 DDC (I C) interface ...................................................................................................................... 16 2.5.4 SDIO interface ............................................................................................................................. 16 2.6 2.7 Pin definition .............................................................................................................. 18 3.1 Audio ................................................................................................................................................. 16 GPIO ................................................................................................................................................... 17 Pin assignment ................................................................................................................................... 18 Electrical specifications .............................................................................................. 23 4.1 Absolute maximum rating .................................................................................................................. 23 4.1.1 Maximum ESD ............................................................................................................................. 23 4.2 Operating conditions .......................................................................................................................... 24 UBX-13004573 - R07 Objective Specification Contents Page 3 of 47 TOBY-L2 series - Data Sheet 4.2.1 Operating temperature range ...................................................................................................... 24 4.2.2 Supply/power pins ....................................................................................................................... 24 4.2.3 4.2.4 Current consumption .................................................................................................................. 25 LTE RF characteristics ................................................................................................................... 27 4.2.5 3G RF characteristics ................................................................................................................... 29 4.2.6 4.2.7 2G RF characteristics ................................................................................................................... 30 ANT_DET pin ............................................................................................................................... 30 4.2.8 PWR_ON pin ............................................................................................................................... 31 4.2.9 4.2.10 RESET_N pin ................................................................................................................................ 31 SIM pins ...................................................................................................................................... 32 4.2.11 USB pins ...................................................................................................................................... 32 4.2.12 4.2.13 Generic Digital Interfaces pins ..................................................................................................... 33 DDC (I C) pins.............................................................................................................................. 33 4.3 Parameters for ATEX applications ....................................................................................................... 34 Mechanical specifications .......................................................................................... 35 Qualification and approvals ...................................................................................... 36 6.1 6.2 Reliability tests .................................................................................................................................... 36 Approvals ........................................................................................................................................... 36 Product handling & soldering .................................................................................... 37 7.1 Packaging ........................................................................................................................................... 37 7.1.1 Reels ........................................................................................................................................... 37 7.1.2 Tapes .......................................................................................................................................... 38 7.2 7.3 Moisture Sensitivity Levels ................................................................................................................... 39 Reflow soldering ................................................................................................................................. 39 7.4 ESD precautions.................................................................................................................................. 39 Default settings .......................................................................................................... 40 Labeling and ordering information........................................................................... 41 9.1 Product labeling.................................................................................................................................. 41 9.2 9.3 Explanation of codes........................................................................................................................... 41 Ordering information .......................................................................................................................... 42 Appendix .......................................................................................................................... 43 A Glossary ...................................................................................................................... 43 Related documents........................................................................................................... 45 Revision history ................................................................................................................ 46 Contact .............................................................................................................................. 47 UBX-13004573 - R07 Objective Specification Contents Page 4 of 47 TOBY-L2 series - Data Sheet 1 Functional description 1.1 Overview The TOBY-L2 series comprises LTE/3G/2G multi-mode modules in the very small LGA form-factor (35.6 x 24.8 mm) that are easy to integrate in compact designs. TOBY-L2 series modules support up to six LTE bands, five UMTS/DC-HSPA+ bands and four GSM/(E)GPRS bands for voice and/or data transmission. TOBY-L2 series modules are form-factor compatible with the other popular u-blox cellular module families: this allows customers to take the maximum advantage of their hardware and software investments, and provides very short time-to-market. With LTE category 4 data rates at up to 150 Mb/s (downlink) and 50 Mb/s (uplink), the modules are ideal for applications requiring the highest data-rates and high-speed internet access. TOBY-L2 series modules are the perfect choice for consumer fixed-wireless terminals, mobile routers and gateways, and applications requiring video streaming. They are also optimally suited for industrial (M2M) applications, such as remote access to video cameras, digital signage, telehealth, and security and surveillance systems. 1.2 Product features Antenna supervisor MIMO 2x2 / Rx Diversity Jamming detection Embedded TCP/UDP stack Embedded HTTP,FTP FOTA eCall / ERA GLONASS Dual stack IPv4/IPv6 □ ● ● 2,4,5 24 6 850/1900 13,17 ● ● ● ● ● ● ● ● TOBY-L210 4 1,3,5 850/900 24 6 12 Quad 7,8,20 1900/2100 ○ ● ○ □ ● ● TOBY-L280 4 1,3,5, 850/900 24 6 12 Quad 7,8,28 1900/2100 ● ● ● ● ● TOBY-L201 4 ● = supported by all product versions ○ = supported by product version “50” and future product versions □ = supported by all product versions except product version “50” F = supported by future product versions Table 1: TOBY-L2 series main features summary UBX-13004573 - R07 Objective Specification Functional description Page 5 of 47 Automotive Network indication Professional Digital audio Analog audio GPIOs 850/900 AWS 12 Quad 1900/2100 GNSS receiver ○ 2,4,5 24 6 7,17 Bands ● TOBY-L200 4 Bands ○ HSUPA category HSDPA category Bands LTE FDD category DCC (I2C) Grade SDIO (Master) Features USB 2.0 Audio UART Interfaces CellLocate® Positioning Standard GSM Assist Now Software UMTS GNSS via modem LTE GPRS/EDGE multi-slot class Module TOBY-L2 series - Data Sheet 1.3 Block diagram PAs Filters LNAs Filters Duplexer Switch ANT1 Filters ANT_DET DDC(I2C) PAs Duplexer Filters LNAs Filters Filters LNAs Filters Filters LNAs Filters Filters SDIO RF Transceiver UART Memory Cellular Base-band Processor Switch ANT2 SIM 26 MHz 32.768 kHz USB GPIO Digital audio (I2S) Host Select VCC (Supply) Power On V_BCKP (RTC) Power Management Unit V_INT (I/O) External Reset Figure 1: TOBY-L2 series block diagram The TOBY-L200-00S and TOBY-L210-00S modules do not support the following interfaces, which should be left unconnected and should not be driven by external devices: VBUS USB detect (VUSB_DET) UART interface SDIO interface DCC (I C) interface I S digital audio interface Antenna detection (ANT_DET) Host Select functions General Purpose Inputs / Outputs (GPIO) The TOBY-L201-01S and TOBY-L280-00S modules do not support the following interfaces, which should be left unconnected and should not be driven by external devices: VBUS USB detect (VUSB_DET) SDIO interface DCC (I C) interface I S digital audio interface Antenna detection (ANT_DET) Host Select functions General Purpose Inputs / Outputs (GPIO) UBX-13004573 - R07 Objective Specification Functional description Page 6 of 47 TOBY-L2 series - Data Sheet The TOBY-L200-50S and TOBY-L210-50S modules, i.e. the “50” product versions, do not support the following interfaces, which should be left unconnected and should not be driven by external devices: o VBUS USB detect (VUSB_DET) DCC (I C) interface I S digital audio interface Antenna detection (ANT_DET) Host Select functions General Purpose Inputs / Outputs (GPIO) 1.4 Product description TOBY-L2 series modules provide 4G LTE, 3G WCDMA/DC-HSPA+, 2G GSM/(E)GPRS multi-mode technology: TOBY-L200 and TOBY-L201 are mainly designed for operation in America TOBY-L210 is mainly designed for operation in Europe, Asia and other countries TOBY-L280 is mainly designed for operation in south-east Asia and Oceania 4G LTE 3G UMTS/HSDPA/HSUPA 2G GSM/GPRS/EDGE 3GPP Release 9 Long Term Evolution (LTE) Evolved Uni.Terrestrial Radio Access (E-UTRA) Frequency Division Duplex (FDD) DL Multi-Input Multi-Output (MIMO) 2 x 2 3GPP Release 8 Dual-Cell HS Packet Access (DC-HSPA+) UMTS Terrestrial Radio Access (UTRA) Frequency Division Duplex (FDD) DL Rx diversity 3GPP Release 8 Enhanced Data rate GSM Evolution (EDGE) GSM EGPRS Radio Access (GERA) Time Division Multiple Access (TDMA) DL Advanced Rx Performance Phase 1 Band support: TOBY-L200: Band 17 (700 MHz) Band 5 (850 MHz) Band 4 (1700 MHz) Band 2 (1900 MHz) Band 7 (2600 MHz) TOBY-L201: Band 17 (700 MHz) Band 13 (750 MHz) Band 5 (850 MHz) Band 4 (1700 MHz) Band 2 (1900 MHz) TOBY-L210: Band 20 (800 MHz) Band 5 (850 MHz) Band 8 (900 MHz) Band 3 (1800 MHz) Band 1 (2100 MHz) Band 7 (2600 MHz) TOBY-L280: Band 28 (750 MHz) Band 5 (850 MHz) Band 8 (900 MHz) Band 3 (1800 MHz) Band 1 (2100 MHz) Band 7 (2600 MHz) Band support: TOBY-L200: Band 5 (850 MHz) Band 8 (900 MHz) Band 4 (AWS, i.e. 1700 MHz) Band 2 (1900 MHz) Band 1 (2100 MHz) TOBY-L201: Band 5 (850 MHz) Band 2 (1900 MHz) Band support TOBY-L200: GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz TOBY-L210: Band 5 (850 MHz) Band 8 (900 MHz) Band 2 (1900 MHz) Band 1 (2100 MHz) TOBY-L210: GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz TOBY-L280: Band 5 (850 MHz) Band 8 (900 MHz) Band 2 (1900 MHz) Band 1 (2100 MHz) TOBY-L280: GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz UBX-13004573 - R07 Objective Specification Functional description Page 7 of 47 TOBY-L2 series - Data Sheet 4G LTE 3G UMTS/HSDPA/HSUPA 2G GSM/GPRS/EDGE LTE Power Class Power Class 3 (23 dBm) for LTE mode WCDMA/HSDPA/HSUPA Power Class Power Class 3 (24 dBm) for UMTS/HSDPA/HSUPA mode GSM/GPRS (GMSK) Power Class Power Class 4 (33 dBm) for GSM/E-GSM bands Power Class 1 (30 dBm) for DCS/PCS bands EDGE (8-PSK) Power Class Power Class E2 (27 dBm) for GSM/E-GSM bands Power Class E2 (26 dBm) for DCS/PCS bands Data rate LTE category 4: up to 150 Mb/s DL, 50 Mb/s UL Data Rate TOBY-L200 and TOBY-L201: HSDPA cat.14, up to 21 Mb/s DL1 HSUPA cat.6, up to 5.6 Mb/s UL TOBY-L210 and TOBY-L280: HSDPA cat.24, up to 42 Mb/s DL HSUPA cat.6, up to 5.6 Mb/s UL Data Rate2 GPRS multi-slot class 123, CS1-CS4, up to 85.6 kb/s DL/UL EDGE multi-slot class 123, MCS1-MCS9, up to 236.8 kb/s DL/UL Table 2: TOBY-L2 series LTE, 3G and 2G characteristics 1.5 AT command support The TOBY-L2 series modules support AT commands according to 3GPP standards TS 27.007 [10], TS 27.005 [11] and the u-blox AT command extension. For the complete list of all supported AT commands and their syntax, see the u-blox AT Commands Manual [1]. RIL (Radio Interface Layer) software for Android and Embedded Windows is available for TOBY-L2 series modules free of charge; see the Android RIL Production delivery [3] and Windows Embedded RIL Production delivery [4] application notes for the supported software deliveries and more information. HSDPA category 24 capable GPRS/EDGE multi-slot class determines the number of timeslots available for upload and download and thus the speed at which data can be transmitted and received, with higher classes typically allowing faster data transfer rates. GPRS/EDGE multi-slot class 12 implies a maximum of 4 slots in DL (reception) and 4 slots in UL (transmission) with 5 slots in total. UBX-13004573 - R07 Objective Specification Functional description Page 8 of 47 TOBY-L2 series - Data Sheet 1.6 Supported features Table 3 lists the main features supported by TOBY-L2 modules. For more details see TOBY-L2 / MPCI-L2 series System Integration Manual [2] and u-blox AT Commands Manual [1]. Feature Description Network Indication GPIO configured to indicate the network status: registered home network, registered roaming, voice or data call enabled, no service. The feature can be enabled through the +UGPIOC AT command. Antenna Detection5 The ANT_DET pin provides antenna presence detection capability, evaluating the resistance from ANT1 and ANT2 pins to GND by means of an external antenna detection circuit implemented on the application board. The antenna detection feature can be enabled through the +UANTR AT command. Jamming detection5 Detects “artificial” interference that obscures the operator’s carriers entitled to give access to the radio service and reports the start and stop of such conditions to the application processor (AP). The AP can react appropriately by e.g. switching off the radio transceiver to reduce power consumption and monitoring the environment at regular intervals. The feature can be enabled and configured through the +UCD AT command. Embedded TCP and UDP Embedded TCP/IP and UDP/IP stack including direct link mode for TCP and UDP sockets. stack6 Sockets can be set in Direct Link mode to establish a transparent end to end communication with an already connected TCP or UDP socket via serial interface. FTP6, FTPS5 File Transfer Protocol as well as Secure File Transfer Protocol (SSL encryption of FTP control channel) functionalities are supported via AT commands. HTTP6, HTTPS5 Hyper-Text Transfer Protocol as well as Secure Hyper-Text Transfer Protocol (SSL encryption) functionalities are supported via AT commands. HEAD, GET, POST, DELETE and PUT operations are available. GNSS via modem5 Full access to u-blox positioning chips and modules is available through a dedicated DDC (I 2C) interface. This means that from any host processor a single serial port can control the cellular module and the positioning chip or module. For more details see the GNSS Implementation Application Note [5]. Embedded AssistNow Software5 Embedded AssistNow Online and AssistNow Offline clients are available to provide better GNSS performance and faster Time-to-First-Fix. An AT command can enable / disable the clients. CellLocate®5 Enables the estimation of device position based on the parameters of the mobile network cells visible to the specific device based on the CellLocate® database: Normal scan: only the parameters of the visible home network cells are sent Deep scan: the parameters of all surrounding cells of all mobile operators are sent CellLocate® is available via a set of AT commands for CellLocate® service configuration and position request. Hybrid Positioning5 The current module position is provided by a u-blox positioning chip or module or the estimated position from CellLocate® depending on which method provides the best and fastest solution according to the user configuration. Hybrid positioning is available via a set of AT commands that allow the configuration and the position request. Wi-Fi via modem7 Full access to u-blox short range communication Wi-Fi modules is available through a dedicated SDIO interface. This means that from any host processor a single serial port can control the cellular module and the short range communication module. All the management software for the Wi-Fi module operations runs inside the cellular module in addition to those required for cellular-only operation: Wi-Fi driver, Web User Interface (WebUI), Connection Config Manager. For more details see the Wi-Fi / Cellular Integration Application Note [8]. Firmware update Over AT commands (FOAT) Firmware module update over AT command interfaces (UART, USB). The feature can be enabled and configured through the +UFWUPD AT command. Firmware update Over The Air (FOTA)6 Firmware module update over the LTE/3G/2G air interface. The feature can be enabled and configured through the +UFWINSTALL AT command. LTE DL MIMO 2x2 and 3G DL Rx Diversity Improved cellular link quality and reliability on all operating bands. Not supported by “50” product versions Not supported by “00”, “01” and “50” product versions. Not supported by “00” and “50” product versions. Not supported by “00” and “01” product versions. UBX-13004573 - R07 Objective Specification Functional description Page 9 of 47 TOBY-L2 series - Data Sheet Feature Description Smart Temperature Supervisor8 Constant monitoring of the module board temperature: Warning notification when the temperature approaches an upper or lower predefined threshold Shutdown notified and forced when the temperature value is outside the specified range (shutdown suspended in case of an emergency call in progress) The Smart Temperature Supervisor feature can be enabled and configured through the +USTS AT command. The sensor measures board temperature, which can differ from ambient temperature. SIM Access Profile (SAP) Allows access and use of a remote SIM card/chip instead of the local SIM card/chip directly connected to the module SIM interface. The module acts as an SAP client establishing a connection and performing data exchange to an SAP server directly connected to the remote SIM. The modules provide a dedicated USB SAP channel and dedicated multiplexer SAP channel over UART for communication with the remote SIM card. In-Band Modem8 In-Band modem solution for eCall and ERA-GLONASS emergency call applications over cellular networks implemented according to the 3GPP TS 26.267 specification [13] When activated, the in-vehicle eCall / ERA-GLONASS system (IVS) creates an emergency call carrying both voice and data (including vehicle position data) directly to the nearest Public Safety Answering Point (PSAP) to determine whether rescue services should be dispatched to the known position. Power saving The power saving configuration is by default disabled, but it can be enabled and configured using the +UPSV AT command. When the power saving is enabled, the module automatically enters the low power idle-mode whenever possible, reducing current consumption. During idle-mode, the module processor core runs with the RTC 32 kHz reference clock, which is generated by the internal 32 kHz oscillator. SMS via IMS9 Allows SMS via embedded IP Multimedia Subsystem Table 3: TOBY-L2 series main supported features ® u-blox is extremely mindful of user privacy. When a position is sent to the CellLocate server u-blox is unable to track the SIM used or the specific device. Not supported by “00”, “01” and “50” product versions. Not supported by “00” and “50” product versions. UBX-13004573 - R07 Objective Specification Functional description Page 10 of 47 TOBY-L2 series - Data Sheet 2 Interfaces 2.1 Power management 2.1.1 Module supply input (VCC) TOBY-L2 series modules must be supplied through the VCC pins by a DC power supply. Voltage must be stable, because during operation the current drawn from VCC can vary significantly, based on the power consumption profile of the LTE/3G/2G technologies (described in the TOBY-L2 / MPCI-L2 series System Integration Manual [2]). 2.1.2 RTC supply input / output (V_BCKP) When VCC voltage is within the valid operating range, the internal Power Management Unit (PMU) supplies the Real Time Clock (RTC) and the same supply voltage is available on the V_BCKP pin. If the VCC voltage is under the minimum operating limit (e.g. during not powered mode), the V_BCKP pin can externally supply the RTC. 2.1.3 Generic digital interfaces supply output (V_INT) TOBY-L2 series modules provide a 1.8 V supply rail output on the V_INT pin, which is internally generated when the module is switched on. The same voltage domain is used internally to supply the generic digital interfaces of the modules. The V_INT supply output can be used in place of an external discrete regulator. 2.2 Antenna interfaces 2.2.1 Antenna RF interfaces The modules have two RF pins with a characteristic impedance of 50 . The primary antenna pin (ANT1) supports both Tx and Rx, providing the main antenna interface, while the secondary antenna pin (ANT2) supports Rx only for the LTE MIMO 2x2 and 3G Rx diversity configurations. 2.2.2 Antenna detection The antenna detection is not supported by “00”, “01” and “50” product versions. The ANT_DET pin is an Analog to Digital Converter (ADC) input with a current source provided by TOBY-L2 modules to sense the antenna presence (as an optional feature). It evaluates the resistance from ANT1 and ANT2 pins to GND by means of an external antenna detection circuit implemented on the application board. (For more details, see the TOBY-L2 / MPCI-L2 series System Integration Manual [2] and the u-blox AT Commands Manual [1].) 2.3 System functions 2.3.1 Module power-on TOBY-L2 series can be switched on in one of the following ways: Rising edge on the VCC pin to a valid voltage for module supply, i.e. applying module supply Low level on the PWR_ON pin, which is normally set high by an internal pull-up, for a valid time period when the applied VCC voltage is within the valid operating range (see section 4.2.8). The PWR_ON line should be driven by open drain, open collector or contact switch. UBX-13004573 - R07 Objective Specification Interfaces Page 11 of 47 TOBY-L2 series - Data Sheet Low level on the RESET_N pin, which is normally set high by an internal pull-up, for a valid time period when the applied VCC voltage is within the valid operating range (see section 4.2.9). The RESET_N line should be driven by open drain, open collector or contact switch. RTC alarm, i.e. pre-programmed scheduled time by AT+CALA command 2.3.2 Module power-off TOBY-L2 series can be properly switched off by: AT+CPWROFF command (see the u-blox AT Commands Manual [1]). The current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. An abrupt under-voltage shutdown occurs on TOBY-L2 series modules when the VCC supply is removed. If this occurs, it is not possible to store the current parameter settings in the module’s non-volatile memory or to perform the proper network detach. An abrupt shutdown occurs on TOBY-L2 series modules when a low level is applied on the RESET_N pin, which is normally set high by an internal pull-up, for a valid time period (see the section 4.2.9). This causes an abrupt shutdown of the module: the current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. An over-temperature or an under-temperature shutdown occurs on TOBY-L2 modules when the temperature measured within the cellular module reaches the dangerous area, if the optional Smart Temperature Supervisor feature is enabled and configured by the dedicated AT command. For more details see the TOBY-L2 / MPCI-L2 series System Integration Manual [2] and the u-blox AT Commands Manual [1], +USTS AT command. Smart Temperature Supervisor is not supported by “00”, “01” and “50” product versions. 2.3.3 Module reset TOBY-L2 series modules can be reset (rebooted) by: AT+CFUN command (see the u-blox AT Commands Manual [1]). This causes an “internal” or “software” reset of the module. The current parameter settings are saved in the module’s non-volatile memory and a proper network detach is performed. An abrupt “external” or “hardware” reset occurs when a low level is applied to the RESET_N pin, which is normally set high by an internal pull-up, for a valid time period (see the section 4.2.9). This causes an “external” or “hardware” reset of the module. The current parameter settings are not saved in the module’s non-volatile memory and a proper network detach is not performed. The RESET_N line should be driven by open drain, open collector or contact switch. 2.3.4 Module configuration selection by host processor The selection of the module configuration by the host application processor over HOST_SELECT0 and HOST_SELECT1 pins is not supported by “00”, “01” and “50” product versions. TOBY-L2 series modules include two input pins (HOST_SELECT0, HOST_SELECT1) for the selection of the module configuration by the host application processor. UBX-13004573 - R07 Objective Specification Interfaces Page 12 of 47 TOBY-L2 series - Data Sheet 2.4 SIM 2.4.1 SIM interface A SIM card interface is provided on the VSIM, SIM_IO, SIM_CLK, SIM_RST pins: the high-speed SIM/ME interface is implemented as well as the automatic detection of the required SIM supporting voltage. Both 1.8 V and 3 V SIM types are supported (1.8 V and 3 V ME). Activation and deactivation with automatic voltage switch from 1.8 V to 3 V is implemented, according to ISO-IEC 7816-3 specifications. The SIM driver supports the PPS procedure for baud-rate selection, according to the values proposed by the SIM card/chip. 2.4.2 SIM detection The SIM detection is not supported by “00”, “01” and “50” product versions. TOBY-L2 series modules provide the SIM detection function over GPIO to sense the SIM card physical presence (as an optional feature) when the specific GPIO pin of the module is properly connected to the mechanical switch of the SIM car holder (for more details see the TOBY-L2 / MPCI-L2 series System Integration Manual [2]). 2.5 Serial communication TOBY-L2 series provides the following serial communication interfaces: UART interface: asynchronous serial interface available for the communication with a DTE host application processor (AT commands, data communication, FW update by means of FOAT) and for diagnostic USB interface: High-Speed USB 2.0 compliant interface available for the communication with a USB host application processor (AT commands, data communication, FW update by means of the FOAT feature), for FW update by means of the u-blox EasyFlash tool and for diagnostic DDC interface: I C bus compatible interface available for the communication with u-blox GNSS positioning chips/modules and with external I C devices as an audio codec SDIO interface: Secure Digital Input Output interface available for the communication with an external Wi-Fi chip or module 2.5.1 UART interface The UART interface is not supported by TOBY-L200-00S and TOBY-L210-00S modules versions. The DTR, DSR and DCD signals are not supported by TOBY-L200-50S, TOBY-L210-50S modules versions. TOBY-L2 series modules include a 9-wire unbalanced asynchronous serial interface (UART) for communication with an application host processor (AT commands, data communication, FW update by means of the FOAT feature) and for diagnostic purpose. UART features are: Complete serial port with RS-232 functionality conforming to the ITU-T V.24 Recommendation [17], with CMOS compatible signal levels (0 V for low data bit or ON state and 1.8 V for high data bit or OFF state) Data lines (RXD as output, TXD as input), hardware flow control lines (CTS as output, RTS as input), modem status and control lines (DTR as input, DSR as output, DCD as output, RI as output) are provided Hardware flow control (default value), software flow control, or none flow control are supported Software flow control is not supported by “00”, “01” and “50” module product versions. UBX-13004573 - R07 Objective Specification Interfaces Page 13 of 47 TOBY-L2 series - Data Sheet Power saving indication available on the hardware flow control output (CTS line): the line is driven to the OFF state when the module is not prepared to accept data by the UART interface Power saving control over the RTS input or the DSR input can be enabled via AT+UPSV command (for more details see u-blox AT Commands Manual [1] and TOBY-L2 / MPCI-L2 series System Integration Manual [2]) The following baud rates are supported: 9600, 19200, 38400, 57600, 115200 (default baud rate when autobauding is disabled or not supported), 230400, 460800 and 921600 b/s One-shot autobauding is supported and it is by default enabled: automatic baud rate detection is performed only once, at module start up. After the detection, the module works at the fixed baud rate (the detected one) and the baud rate can only be changed via AT command (see u-blox AT Commands Manual [1], +IPR). The automatic baud rate recognition (autobauding) is not supported by “50” module product version. Frame format can be: o 8N2 (8 data bits, no parity, 2 stop bits) 8N1 (8 data bits, no parity, 1 stop bit), default frame configuration 8E1 (8 data bits, even parity, 1 stop bit) 8O1 (8 data bits, odd parity, 1 stop bit) 7N2 (7 data bits, no parity, 2 stop bits) 7N1 (7 data bits, no parity, 1 stop bit) 7E1 (7 data bits, even parity, 1 stop bit) 7O1 (7 data bits, odd parity, 1 stop bit) Automatic frame format recognition is not supported by “00”, “01” and “50” module product versions. UART serial interface can be conveniently configured through AT commands. For more details see the u-blox AT Commands Manual [1] (+IPR, +ICF, +IFC, &K, \Q, +UPSV AT command) and TOBY-L2 / MPCI-L2 series System Integration Manual [2]. 2.5.1.1 Multiplexer protocol The GNSS tunneling and the SIM Access Profile (SAP) multiplexer virtual channels are not supported by “00”, “01” and “50” modules product version. TOBY-L2 series modules include multiplexer functionality as per 3GPP TS 27.010 [12] on the UART physical link. This is a data link protocol which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE), allowing a number of simultaneous sessions over the physical link (UART): the user can concurrently use AT interface on one MUX channel and data communication on another MUX channel. The following virtual channels are defined (for more details, see the Mux Implementation Application Note [6]): Channel 0: control Channel 1 – 5: AT commands / data connection Channel 6: GNSS tunneling Channel 7: SIM Access Profile (SAP) UBX-13004573 - R07 Objective Specification Interfaces Page 14 of 47 TOBY-L2 series - Data Sheet 2.5.2 USB interface TOBY-L2 series modules include a high-speed USB 2.0 compliant interface with maximum 480 Mb/s data rate, representing the main interface for transferring high speed data with a host application processor. The module itself acts as a USB device and can be connected to any USB host equipped with compatible drivers. The USB_D+ / USB_D- lines carry the USB data and signaling, providing all the functionalities for the bus attachment, configuration, enumeration, suspension or remote wakeup according to USB 2.0 specification [18]. The additional VUSB_DET input is available as an optional feature to sense the host VBUS voltage (5.0 V typical). The VUSB_DET functionality is not supported by “00”, “01” and “50” product versions: the pin should be left unconnected or it should not be driven high by any external device, because a high logic level applied to the pin will represent a module switch-on event (additional to the ones listed in section 2.3.1) and will prevent reaching the minimum possible consumption with power saving enabled. TOBY-L2 series modules provide by default the following set of USB functions: CDC-ACM modem: AT commands interface is available over this modem COM port RNDIS network adapter: Ethernet-over-USB connection is available over this network adapter The USB of TOBY-L2 series modules can be configured by the AT+UUSBCONF command to select different sets of USB functions available in a mutually exclusive way. The configured USB profile can thus consist of a specific set of functions with various capabilities and purposes, such as: CDC-ACM for AT commands and data CDC-ACM for GNSS tunneling CDC-ACM for SIM Access Profile (SAP) CDC-ACM for diagnostic RNDIS for Ethernet-over-USB CDC-ECM for Ethernet-over-USB CDC-NCM for Ethernet-over-USB MBIM for Ethernet-over-USB CDC-ACM for GNSS tunneling, CDC-ACM for SIM Access Profile (SAP), CDC-NCM and MBIM are not supported by “00”, “01” and “50” product versions. For more details regarding the USB configurations and capabilities, see the TOBY-L2 / MPCI-L2 series System Integration Manual [2] and the u-blox AT Commands Manual [1], +UUSBCONF AT command. USB drivers are available for the following operating system platforms: Windows Vista Windows 7 Windows 8 Windows 8.1 Windows Embedded Compact 7 TOBY-L2 series modules are compatible with standard Linux/Android USB kernel drivers. UBX-13004573 - R07 Objective Specification Interfaces Page 15 of 47 TOBY-L2 series - Data Sheet 2.5.3 DDC (I2C) interface The DDC (I C) interface is not supported by “00”, “01” and “50” product versions. TOBY-L2 series modules include an I C-bus compatible DDC interface (SDA, SCL) available to communicate with a u-blox GNSS receiver and with external I C devices as an audio codec: the TOBY-L2 module acts as an I C master which can communicate with I C slaves in accordance with the I C bus specifications [19]. For more details regarding the DDC (I C) interface usage and the integration with a u-blox GNSS receiver see the TOBY-L2 / MPCI-L2 series System Integration Manual [2], the GNSS Implementation Application Note [7], and the I C and GNSS AT commands description in the u-blox AT Commands Manual [1]. 2.5.4 SDIO interface The SDIO interface is not supported by “00”, “01” modules product versions. TOBY-L2 series modules include a 4-bit Secure Digital Input Output interface (SDIO_D0, SDIO_D1, SDIO_D2, SDIO_D3, SDIO_CLK, SDIO_CMD) designed to communicate with an external u-blox short range Wi-Fi module: the TOBY-L2 cellular module acts as an SDIO host controller which can communicate over the SDIO bus with a compatible u-blox short range Wi-Fi module acting as SDIO device. The SDIO interface is the only one interface of TOBY-L2 cellular modules available for communication between the u-blox cellular module and the u-blox short range Wi-Fi module. The AT commands interface is not available on the SDIO interface of TOBY-L2 series modules. The SDIO interface supports 50 MHz bus clock frequency, which allows a data throughput of 200 Mb/s. For more details regarding the SDIO interface usage and the integration with a u-blox Wi-Fi module see the TOBY-L2 / MPCI-L2 series System Integration Manual [2], the Wi-Fi / Cellular Integration Application Note [8], and the Wi-Fi AT commands description in the u-blox AT Commands Manual [1]. 2.6 Audio Audio is not supported by “00”, “01” and “50” product versions. TOBY-L2 series modules include a 4-wire I S digital audio interface (I2S_TXD, I2S_RXD, I2S_CLK, I2S_WA) that can be configured by AT command to transfer digital audio data with an external device as an audio codec. For more details regarding the I S digital audio interface usage and the integration with an external digital audio device as an audio codec see the TOBY-L2 / MPCI-L2 series System Integration Manual [2] and the audio AT commands description in the u-blox AT Commands Manual [1]. UBX-13004573 - R07 Objective Specification Interfaces Page 16 of 47 TOBY-L2 series - Data Sheet 2.7 GPIO GPIOs are not supported by “00”, “01” and “50” modules product version except for: Wireless Wide Area Network status indication configured on GPIO1 of “00” and “01” product versions Wi-Fi enable function configured on the GPIO1 of “50” product version TOBY-L2 series modules include 14 pins (GPIO1-GPIO6, I2S_TXD, I2S_RXD, I2S_CLK, I2S_WA, DTR, DSR, DCD, RI) that can be configured as general purpose input/output or to provide custom functions as summarized in Table 4 (for further details see the TOBY-L2 / MPCI-L2 series System Integration Manual [2] and the u-blox AT Commands Manual [1]). Function Description Default GPIO Configurable GPIOs Network status indication Network status: registered home network, registered roaming, data transmission, no service GPIO1 GPIO1 GNSS supply enable Enable/disable the supply of u-blox GNSS receiver connected to the cellular module GPIO2 GPIO2 GNSS data ready Sense when u-blox GNSS receiver connected to the module is ready for sending data by the DDC (I2C) GPIO3 GPIO3 GNSS RTC sharing Real Time Clock synchronization signal to u-blox GNSS receiver connected to the cellular module GPIO4 GPIO4 SIM card detection SIM card physical presence detection GPIO5 GPIO5 SIM card hot insertion/removal SIM card hot insertion/removal -- GPIO5 I2S digital audio interface I2S digital audio interface I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA 26 MHz clock output 26 MHz clock output for an external audio codec or an external Wi-Fi chip/module GPIO6 GPIO6 Wi-Fi enable Enable/disable the supply of the external Wi-Fi chip or module connected to the cellular module -- GPIO1, GPIO4, DSR Wi-Fi data ready Sense when the external Wi-Fi chip/module connected to the cellular module is ready for sending data by the SDIO, waking up the cellular module from low power idle mode -- GPIO3, DTR Wi-Fi reset Reset the external Wi-Fi chip or module connected to the cellular module -- GPIO3, DCD Wi-Fi power saving Enable/disable the low power mode of the external Wi-Fi chip/module connected to the cellular module -- GPIO2, RI 32 kHz clock output 32 kHz clock output for an external Wi-Fi chip or module -- GPIO6 Antenna tuning 4-bit tunable antenna control signals mapping the actual operating RF band over a 4-pin interface provided for the implementation of external antenna tuning solutions -- I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA DSR, DTR, DCD, RI DSR UART data set ready output DSR DSR DTR UART data terminal ready input DTR DTR DCD UART data carrier detect output DCD DCD RI UART ring indicator output RI RI General purpose input Input to sense high or low digital level -- All General purpose output Output to set the high or the low digital level -- All Pin disabled Tri-state with an internal active pull-down enabled -- All Table 4: GPIO custom functions configuration UBX-13004573 - R07 Objective Specification Interfaces Page 17 of 47 TOBY-L2 series - Data Sheet 3 Pin definition GND RSVD GND RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD HOST_SELECT0 25 GPIO4 52 24 GPIO3 I2S_RXD 53 23 RESET_N SCL 54 22 GPIO2 SDA 55 21 GPIO1 SIM_CLK 56 20 PWR_ON SIM_IO 57 19 RSVD SIM_RST 58 18 RSVD VSIM 59 17 RXD GPIO5 60 TXD GPIO6 61 TOBY-L2 16 15 CTS HOST_SELECT1 62 RTS SDIO_D2 63 Top view 14 13 DTR SDIO_CLK 64 12 DCD SDIO_CMD 65 11 RI SDIO_D0 66 10 DSR SDIO_D3 67 RSVD SDIO_D1 68 RSVD GND 69 RSVD VCC 70 RSVD VCC 71 V_INT VCC 72 VUSB_DET GND 73 V_BCKP GND 74 GND ANT_DET 75 RSVD 143 142 147 141 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 114 113 111 115 110 109 107 106 105 104 103 102 101 99 98 97 96 95 94 GND 79 80 81 82 83 84 85 86 87 88 89 GND 78 112 116 ANT2 76 117 Pin 93-152: GND 108 77 118 93 90 91 92 GND 119 RSVD 120 121 GND 122 100 145 146 140 GND I2S_CLK GND USB_D- 26 144 148 GND 51 RSVD USB_D+ 27 149 RSVD I2S_TXD 30 RSVD 150 GND 50 31 28 151 GND I2S_WA 32 29 152 ANT1 49 43 42 41 40 39 38 37 36 35 34 33 GND RSVD 44 GND 48 45 GND RSVD 46 RSVD 47 GND RSVD GND 3.1 Pin assignment Figure 2: TOBY-L2 series pin assignment (top view) UBX-13004573 - R07 Objective Specification Pin definition Page 18 of 47 TOBY-L2 series - Data Sheet No Name Power domain I/O Description Remarks RSVD GND GND N/A N/A RESERVED pin Ground Leave unconnected. All GND pins must be connected to ground. V_BCKP I/O RTC supply Input/ Output VUSB_DET VBUS VBUS USB detect input V_INT GDI Generic Digital Interfaces supply output RSVD N/A RESERVED pin RSVD N/A RESERVED pin 3.0 V (typical) generated by the module when VCC supply voltage is within valid operating range. See section 4.2.2 for detailed electrical specs. Note: leave unconnected as VUSB_DET functionality is not supported by ‘00’, ‘01’ and ‘50’ product versions. Input for VBUS (5 V typical) USB supply sense. See section 4.2.11 for detailed electrical specs. 1.8 V (typical) generated by the module when it is switched-on. See section 4.2.2 for detailed electrical specs. This pin has special function: it must be connected to GND to allow module to work properly. Leave unconnected. RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. 10 DSR GDI O/ I/O UART data set ready / GPIO 11 RI GDI O/ I/O UART ring indicator / GPIO 12 DCD GDI O/ I/O UART data carrier detect / GPIO Note: UART DSR not supported by TOBY-L200-00S, TOBY-L210-00S, TOBY-L200-50S, TOBY-L210-50S; GPIO not supported by ‘00’, ‘01’, ‘50’ product versions. Circuit 107 (DSR) in ITU-T V.24, configurable as GPIO. PU/PD class H. Value at internal reset: T/PU. See section 4.2.12 for detailed electrical specs. Note: UART RI not supported by TOBY-L200-00S and TOBY-L210-00S module product versions; GPIO not supported by ‘00’, ‘01’, ‘50’ product versions. Circuit 125 (RI) in ITU-T V.24, configurable as GPIO. PU/PD class H. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: UART DCD not supported by TOBY-L200-00S, TOBY-L210-00S, TOBY-L200-50S, TOBY-L210-50S; GPIO not supported by ‘00’, ‘01’, ‘50’ product versions. Circuit 109 (DCD) in ITU-T V.24, configurable as GPIO. PU/PD class H. Value at internal reset: T/PU. See section 4.2.12 for detailed electrical specs. 13 DTR GDI I/ I/O UART data terminal ready / GPIO 14 RTS GDI UART ready to send 15 CTS GDI UART clear to send UBX-13004573 - R07 Objective Specification Note: UART DTR not supported by TOBY-L200-00S, TOBY-L210-00S, TOBY-L200-50S, TOBY-L210-50S; GPIO not supported by ‘00’, ‘01’, ‘50’ product versions. Circuit 108/2 (DTR) in ITU-T V.24, configurable as GPIO. Internal active pull-up to V_INT when set as DTR. PU/PD class H. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: UART RTS not supported by TOBY-L200-00S and TOBY-L210-00S module product versions. Circuit 105 (RTS) in ITU-T V.24. Internal active pull-up to V_INT. PU/PD class H. Value at internal reset: T/PU. See section 4.2.12 for detailed electrical specs. Note: UART CTS not supported by TOBY-L200-00S and TOBY-L210-00S module product versions. Circuit 106 (CTS) in ITU-T V.24. PU/PD class H. Value at internal reset: T/PU. See section 4.2.12 for detailed electrical specs. Pin definition Page 19 of 47 TOBY-L2 series - Data Sheet No Name Power domain I/O Description Remarks 16 TXD GDI UART data input 17 RXD GDI UART data output Note: UART TXD not supported by TOBY-L200-00S and TOBY-L210-00S module product versions. Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: UART RXD not supported by TOBY-L200-00S and TOBY-L210-00S module product versions. Circuit 104 (RxD) in ITU-T V.24. PU/PD class M. Value at internal reset: T/PU. See section 4.2.12 for detailed electrical specs. 18 19 RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. 20 PWR_ON POS Power-on input 21 GPIO1 GDI I/O GPIO 22 GPIO2 GDI I/O GPIO 23 RESET_N ERS External reset input 24 GPIO3 GDI I/O GPIO 25 GPIO4 GDI I/O GPIO 26 HOST_SELECT0 GDI Input for the selection of module configuration by the host processor Internal active pull-up to VCC enabled. See section 4.2.8 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Internal active pull-up to VCC enabled. See section 4.2.9 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. 27 USB_D- USB I/O USB Data Line D- 90 nominal differential impedance Pull-up, pull-down and series resistors as required by the USB Revision 2.0 specification [18] are part of the USB pin driver and need not be provided externally. See section 4.2.11 for detailed electrical specs. 28 USB_D+ USB I/O USB Data Line D+ 29 30 RSVD GND GND N/A N/A RESERVED pin Ground 90 nominal differential impedance Pull-up, pull-down and series resistors as required by the USB Revision 2.0 specification [18] are part of the USB pin driver and need not be provided externally. See section 4.2.11 for detailed electrical specs. Leave unconnected. All GND pins must be connected to ground. 31 RSVD N/A RESERVED pin Leave unconnected. 32 33 GND RSVD GND N/A N/A Ground RESERVED pin All GND pins must be connected to ground. Leave unconnected. 34 35 RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. 36 37 RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. 38 39 RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. 40 RSVD N/A RESERVED pin Leave unconnected. 41 42 RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. UBX-13004573 - R07 Objective Specification Pin definition Page 20 of 47 TOBY-L2 series - Data Sheet No Name Power domain I/O Description Remarks 43 44 RSVD GND GND N/A N/A RESERVED pin Ground Leave unconnected. All GND pins must be connected to ground. 45 46 RSVD GND GND N/A N/A RESERVED pin Ground Leave unconnected. All GND pins must be connected to ground. 47 48 RSVD RSVD N/A N/A RESERVED pin RESERVED pin Leave unconnected. Leave unconnected. 49 RSVD N/A RESERVED pin Leave unconnected. 50 I2S_WA GDI I/O / I/O I2S word alignment / GPIO 51 I2S_TXD GDI O/ I/O I2S transmit data / GPIO 52 I2S_CLK GDI I/O / I/O I2S clock / GPIO 53 I2S_RXD GDI I/ I/O I2S receive data / GPIO Note: not supported by ‘00’, ‘01’, ‘50’ product versions I2S word alignment, otherwise configurable as GPIO. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions I2S transmit data out, otherwise configurable as GPIO. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions I2S serial clock, otherwise configurable as GPIO. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions I2S receive data in, otherwise configurable as GPIO. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs 54 SCL DDC I2C bus clock line 55 SDA DDC I/O I2C bus data line 56 SIM_CLK SIM SIM clock 57 SIM_IO SIM I/O SIM data 58 SIM_RST SIM SIM reset 59 VSIM SIM supply output 60 GPIO5 GDI I/O GPIO 61 GPIO6 GDI I/O GPIO 62 HOST_SELECT1 GDI Input for the selection of module configuration by the host processor 63 SDIO_D2 GDI I/O SDIO serial data [2] 64 SDIO_CLK GDI SDIO serial clock 65 SDIO_CMD GDI I/O SDIO command UBX-13004573 - R07 Objective Specification Note: not supported by ‘00’, ‘01’, ‘50’ product versions Fixed open drain. No internal pull-up. Value at internal reset: T. See section 4.2.13 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions Fixed open drain. No internal pull-up. Value at internal reset: T. See section 4.2.13 for detailed electrical specs. See section 4.2.10 for detailed electrical specs. Internal 4.7 k pull-up resistor to VSIM. See section 4.2.10 for detailed electrical specs. See section 4.2.10 for detailed electrical specs. VSIM = 1.8 V typical or 3.0 V typical generated by the module according to the SIM card/chip voltage type. See section 4.2.2 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’, ‘50’ product versions PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’ product versions. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’ product versions. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’ product versions. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Pin definition Page 21 of 47 TOBY-L2 series - Data Sheet No Name Power domain I/O Description Remarks 66 SDIO_D0 GDI I/O SDIO serial data [0] 67 SDIO_D3 GDI I/O SDIO serial data [3] 68 SDIO_D1 GDI I/O SDIO serial data [1] Note: not supported by ‘00’, ‘01’ product versions. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’ product versions. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. Note: not supported by ‘00’, ‘01’ product versions. PU/PD class M. Value at internal reset: T/PD. See section 4.2.12 for detailed electrical specs. 69 70 GND VCC GND VCC N/A Ground Module supply input 71 VCC VCC Module supply input 72 VCC VCC Module supply input 73 GND GND N/A Ground All GND pins must be connected to ground. All VCC pins must be connected to external supply. See sections 4.2.2 / 4.2.3 for detailed electrical specs. All VCC pins must be connected to external supply. See sections 4.2.2 / 4.2.3 for detailed electrical specs. All VCC pins must be connected to external supply. See sections 4.2.2 / 4.2.3 for detailed electrical specs. All GND pins must be connected to ground. 74 75 GND ANT_DET GND ADC N/A Ground Antenna detection All GND pins must be connected to ground. Note: not supported by ‘00’, ‘01’, ‘50’ product versions 76 77 GND RSVD GND N/A N/A Ground RESERVED pin All GND pins must be connected to ground. Leave unconnected. 78 GND GND N/A Ground All GND pins must be connected to ground. 79 80 GND GND GND GND N/A N/A Ground Ground All GND pins must be connected to ground. All GND pins must be connected to ground. 81 ANT1 ANT I/O Primary antenna 82 GND GND N/A Ground 50 nominal characteristic impedance. Main Tx / Rx antenna interface. See section 4.2.4 / 4.2.5 / 4.2.6 for details. All GND pins must be connected to ground. 83 84 GND RSVD GND N/A N/A Ground RESERVED pin All GND pins must be connected to ground. Leave unconnected. 85 GND GND N/A Ground All GND pins must be connected to ground. 86 87 GND ANT2 GND ANT N/A Ground Secondary antenna All GND pins must be connected to ground. 88 89 GND GND GND GND N/A N/A Ground Ground 50 nominal characteristic impedance Rx only for Down-Link MIMO 2x2 and Rx diversity. See section 4.2.4 / 4.2.5 / 4.2.6 for details. All GND pins must be connected to ground. All GND pins must be connected to ground. 90 GND GND N/A Ground All GND pins must be connected to ground. 91 92 RSVD GND GND N/A N/A RESERVED pin Ground Leave unconnected. All GND pins must be connected to ground. 93-152 GND GND N/A Ground All GND pins must be connected to ground. Table 5: TOBY-L2 series pin-out For more information about the pin-out, see the TOBY-L2 / MPCI-L2 series System Integration Manual [2]. See Appendix A for an explanation of abbreviations and terms used. UBX-13004573 - R07 Objective Specification Pin definition Page 22 of 47 TOBY-L2 series - Data Sheet 4 Electrical specifications Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating section may cause permanent damage. These are stress ratings only. Operating the module at these or at any conditions other than those specified in the Operating Conditions sections (section 4.2) of the specification should be avoided. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Operating condition ranges define those limits within which the functionality of the device is guaranteed. Where application information is given, it is advisory only and does not form part of the specification. 4.1 Absolute maximum rating Limiting values given below are in accordance with the Absolute Maximum Rating System (IEC 134). Symbol Description Condition Min. Max. Unit VCC V_BCKP Module supply voltage RTC supply voltage Input DC voltage at VCC pin Input DC voltage at V_BCKP pin –0.3 –0.3 6.0 6.0 USB GDI USB D+/D- pins Generic digital interfaces Input DC voltage at USB interface pins Input DC voltage at Generic digital interfaces pins 3.6 2.2 DDC DDC interface Input DC voltage at DDC interface pins 2.2 SIM ERS SIM interface External reset signal Input DC voltage at SIM interface pins Input DC voltage at RESET_N pin –0.3 –0.3 3.6 6.0 POS Rho_ANT Power-on input Antenna ruggedness Input DC voltage at PWR_ON pin Output RF load mismatch ruggedness at ANT pins –0.3 6.0 10:1 VSWR Tstg Storage Temperature –40 85 °C Table 6: Absolute maximum ratings The product is not protected against overvoltage or reversed voltages. If necessary, voltage spikes exceeding the power supply voltage specification, given in table above, must be limited to values within the specified boundaries by using appropriate protection devices. 4.1.1 Maximum ESD Parameter Min Typical Max Unit Remarks ESD sensitivity for all pins except ANT1 / ANT2 pins 1000 Human Body Model according to JESD22-A114 ESD sensitivity for ANT1 / ANT2 pins ESD immunity for ANT1 / ANT2 pins 1000 4000 Human Body Model according to JESD22-A114 Contact Discharge according to IEC 61000-4-2 8000 Air Discharge according to IEC 61000-4-2 Table 7: Maximum ESD ratings u-blox cellular modules are Electrostatic Sensitive Devices and require special precautions when handling. See section 7.4 for ESD handling instructions. UBX-13004573 - R07 Objective Specification Electrical specifications Page 23 of 47 TOBY-L2 series - Data Sheet 4.2 Operating conditions Unless otherwise indicated, all operating condition specifications are at an ambient temperature of 25°C. Operation beyond the operating conditions is not recommended and extended exposure beyond them may affect device reliability. 4.2.1 Operating temperature range Parameter Min. Typical Max. Unit Remarks Normal operating temperature –20 +25 +65 °C Normal operating temperature range (fully functional and meet 3GPP specifications) Extended operating temperature –40 +85 °C Extended operating temperature range (Occasional deviations from 3GPP specifications may occur, though the module is functional) Table 8: Environmental conditions 4.2.2 Supply/power pins Symbol VCC Parameter Module supply normal operating input voltage 10 Module supply extended operating input voltage 11 V_BCKP Real Time Clock supply input voltage I_BCKP Real Time Clock supply average current consumption, at V_BCKP = 1.8 V Min. Typical Max. Unit 3.40 3.80 4.35 3.20 3.80 4.35 4.2 µA 1.4 Table 9: Input characteristics of Supply/Power pins Symbol Parameter Min. Typical Max. Unit VSIM SIM supply output voltage 1.76 1.80 1.85 2.84 2.90 2.94 V_BCKP Real Time Clock supply output voltage I_BCKP Real Time Clock supply output current capability V_INT Generic Digital Interfaces supply output voltage V_INT_RIPPLE Generic Digital Interfaces supply output voltage ripple I_INT Generic Digital Interfaces supply output current capability 3.00 1.76 1.80 mA 1.85 45 mVpp 70 mA Table 10: Output characteristics of Supply/Power pins 10 Input voltage at VCC must be above the normal operating range minimum limit to switch-on the module. Occasional deviations from the 3GPP specifications may occur. Ensure that input voltage at VCC never drops below the extended operating range minimum limit during module operation: the cellular module may switch-off when the VCC voltage value drops below the extended operating range minimum limit. 11 UBX-13004573 - R07 Objective Specification Electrical specifications Page 24 of 47 TOBY-L2 series - Data Sheet 4.2.3 Current consumption Mode Condition Power Off Mode Averaged current value over a any period, Module switched off 12 13 Tx power Min Typ12 15 Max13 Unit µA Typical values with a matched antenna. Maximum values with a mismatched antenna. UBX-13004573 - R07 Objective Specification Electrical specifications Page 25 of 47 TOBY-L2 series - Data Sheet Idle-Mode (Power Saving enabled by AT+UPSV, module in low power idle-mode, equivalent to +CFUN=4 or +COPS=2) Averaged current value over a 100-ms period, USB not connected 1.1 mA Averaged current value over a 100-ms period, USB connected and suspended 1.3 mA Cyclic Idle/Active-Mode (Power Saving enabled by AT+UPSV, Module registered with network) Averaged current value over a 10-minute period, USB not connected 2.7 mA Averaged current value over a 10-minute period, USB connected and suspended 2.9 mA Active-Mode (Power Saving disabled by AT+UPSV, Module registered with network) Averaged current value over a 10-minute period, USB not connected 35 mA Averaged current value over a 10-minute period, USB connected and not suspended 44 mA 2G Connected Mode (Tx / Rx call enabled) Pulse current14 during a 1-slot GMSK Tx burst, 850/900 MHz bands Maximum 1.9 Averaged current value over a 10-second period, 2G GMSK call, 1 Tx + 1 Rx slot, 850/900 MHz Maximum 340 mA Averaged current value over a 10-second period, 2G GMSK call, 1 Tx + 1 Rx slot, 1800/1900 MHz Maximum 280 mA Averaged current value over a 10-second period, 3G call with Low data rate –55 dBm 250 mA 0 dBm 265 mA 12 dBm 350 mA 18 dBm 460 mA LTE Connected Mode (Tx / Rx call enabled) Min Max13 Condition 3G Connected Mode (Tx / Rx call enabled) Tx power Typ12 Mode 2.5 Unit Maximum 600 mA Averaged current value over a 10-second period, 3G call with Maximum data rate Maximum 640 mA Averaged current value over a 10-second period, LTE call with Low data rate –55 dBm 295 mA 0 dBm 310 mA 12 dBm 390 mA 18 dBm 490 mA Maximum 610 mA Maximum 660 mA Averaged current value over a 10-second period, LTE call with Maximum data rate Table 11: Module VCC current consumption 14 It is recommended to use this figure to dimension maximum current capability of power supply. UBX-13004573 - R07 Objective Specification Electrical specifications Page 26 of 47 TOBY-L2 series - Data Sheet 4.2.4 LTE RF characteristics The LTE bands supported by each TOBY-L2 series module are defined in Table 2, while the following Table 12 describes the Transmitting and Receiving frequencies for each LTE band according to 3GPP TS 36.521-1 [14]. Parameter Min. Max. Unit Remarks Frequency range Band 17 (700 MHz) Uplink 704 716 MHz Module transmit Downlink 734 746 MHz Module receive Frequency range Band 13 (750 MHz) Uplink 777 787 MHz Module transmit Downlink 746 756 MHz Module receive Frequency range Band 28 (750 MHz) Uplink 703 748 MHz Module transmit Downlink 758 803 MHz Module receive Frequency range Band 20 (800 MHz) Uplink 832 862 MHz Module transmit Downlink 791 821 MHz Module receive Frequency range Band 5 (850 MHz) Uplink 824 849 MHz Module transmit Downlink 869 894 MHz Module receive Frequency range Band 8 (900 MHz) Uplink 880 915 MHz Module transmit Downlink 925 960 MHz Module receive Frequency range Band 4 (1700 MHz) Uplink 1710 1755 MHz Module transmit Downlink 2110 2155 MHz Module receive Frequency range Band 3 (1800 MHz) Uplink 1710 1785 MHz Module transmit Downlink 1805 1880 MHz Module receive Frequency range Band 2 (1900 MHz) Uplink 1850 1910 MHz Module transmit Downlink 1930 1990 MHz Module receive Frequency range Band 1 (2100 MHz) Uplink 1920 1980 MHz Module transmit Downlink 2110 2170 MHz Module receive Frequency range Band 7 (2600 MHz) Uplink 2500 2570 MHz Module transmit Downlink 2620 2690 MHz Module receive Table 12: LTE operating RF frequency bands TOBY-L2 series modules include a UE Power Class 3 LTE transmitter (see Table 2), with output power and characteristics according to 3GPP TS 36.521-1 [14]. TOBY-L2 series modules LTE receiver characteristics are compliant to 3GPP TS 36.521-1 [14], with LTE conducted receiver sensitivity performance described in Table 13. UBX-13004573 - R07 Objective Specification Electrical specifications Page 27 of 47 TOBY-L2 series - Data Sheet Parameter Min. Typical Max. Unit Remarks Receiver input sensitivity Band 17 (700 MHz) –103.5 dBm Channel bandwidth = 5 MHz –100.5 dBm Channel bandwidth = 10 MHz Receiver input sensitivity Band 20 (800 MHz) –103.0 dBm Channel bandwidth = 5 MHz –97.0 dBm Channel bandwidth = 20 MHz Receiver input sensitivity Band 5 (850 MHz) –109.0 dBm Channel bandwidth = 1.4 MHz –103.0 dBm Channel bandwidth = 5 MHz –100.5 dBm Channel bandwidth = 10 MHz –110.0 dBm Channel bandwidth = 1.4 MHz –104.5 dBm Channel bandwidth = 5 MHz –101.5 dBm Channel bandwidth = 10 MHz –109.5 dBm Channel bandwidth = 1.4 MHz –103.5 dBm Channel bandwidth = 5 MHz –98.0 dBm Channel bandwidth = 20 MHz –110.0 dBm Channel bandwidth = 1.4 MHz –104.5 dBm Channel bandwidth = 5 MHz –98.5 dBm Channel bandwidth = 20 MHz –110.0 dBm Channel bandwidth = 1.4 MHz –104.0 dBm Channel bandwidth = 5 MHz –98.0 dBm Channel bandwidth = 20 MHz Receiver input sensitivity Band 1 (2100 MHz) –104.5 dBm Channel bandwidth = 5 MHz –98.5 dBm Channel bandwidth = 20 MHz Receiver input sensitivity Band 7 (2600 MHz) –102.5 dBm Channel bandwidth = 5 MHz –97.0 dBm Channel bandwidth = 20 MHz Receiver input sensitivity Band 8 (900 MHz) Receiver input sensitivity Band 4 (1700 MHz) Receiver input sensitivity Band 3 (1800 MHz) Receiver input sensitivity Band 2 (1900 MHz) Condition: 50 source, Throughput > 95%, dual receiver, QPSK modulation, Other settings as per 3GPP TS 36.521-1 [14] Table 13: LTE receiver sensitivity performance UBX-13004573 - R07 Objective Specification Electrical specifications Page 28 of 47 TOBY-L2 series - Data Sheet 4.2.5 3G RF characteristics The 3G bands supported by each TOBY-L2 series module are defined in Table 2, while the following Table 14 describes the Transmitting and Receiving frequencies for each 3G band according to 3GPP TS 34.121-1 [15]. Parameter Min. Max. Unit Remarks Frequency range Band 5 (850 MHz) Uplink Downlink 824 869 849 894 MHz MHz Module transmit Module receive Frequency range Band 8 (900 MHz) Uplink Downlink 880 925 915 960 MHz MHz Module transmit Module receive Frequency range Band 4 (AWS, 1700 MHz) Uplink 1710 1755 MHz Module transmit Downlink Uplink 2110 1850 2155 1910 MHz MHz Module receive Module transmit Downlink Uplink 1930 1920 1990 1980 MHz MHz Module receive Module transmit Downlink 2110 2170 MHz Module receive Frequency range Band 2 (1900 MHz) Frequency range Band 1 (2100 MHz) Table 14: 3G operating RF frequency bands TOBY-L2 series modules include a UE Power Class 3 3G transmitter (see Table 2), with output power and characteristics according to 3GPP TS 34.121-1 [15]. TOBY-L2 series modules 3G receiver characteristics are compliant to 3GPP TS 34.121-1 [15], with 3G conducted receiver sensitivity performance described in Table 15. Parameter Receiver input sensitivity Band 5 (850 MHz) Receiver input sensitivity Band 8 (900 MHz) Receiver input sensitivity Band 4 (AWS, 1700 MHz) Receiver input sensitivity Band 2 (1900 MHz) Receiver input sensitivity Band 1 (2100 MHz) Min. Typical Max. Unit Remarks –112.0 dBm Downlink RF level for RMC @ BER < 0.1 % –112.0 dBm Downlink RF level for RMC @ BER < 0.1 % –111.0 dBm Downlink RF level for RMC @ BER < 0.1 % –111.0 dBm Downlink RF level for RMC @ BER < 0.1 % –111.0 dBm Downlink RF level for RMC @ BER < 0.1 % Condition: 50 source, other settings as per 3GPP TS 34.121-1 [15] Table 15: 3G receiver sensitivity performance UBX-13004573 - R07 Objective Specification Electrical specifications Page 29 of 47 TOBY-L2 series - Data Sheet 4.2.6 2G RF characteristics The 2G bands supported by each TOBY-L2 series module are defined in Table 2, while the following Table 16 describes the Transmitting and Receiving frequencies for each 2G band according to 3GPP TS 51.010-1 [16]. Parameter Min. Max. Unit Remarks Frequency range GSM 850 Uplink Downlink 824 869 849 894 MHz MHz Module transmit Module receive Frequency range E-GSM 900 Uplink Downlink 880 925 915 960 MHz MHz Module transmit Module receive Frequency range DCS 1800 Uplink Downlink 1710 1805 1785 1880 MHz MHz Module transmit Module receive Frequency range PCS 1900 Uplink Downlink 1850 1930 1910 1990 MHz MHz Module transmit Module receive Table 16: 2G operating RF frequency bands TOBY-L2 series modules include a GMSK Power Class 4 transmitter for GSM/E-GSM bands, GMSK Power Class 1 transmitter for DCS/PCS bands, 8-PSK Power Class E2 transmitter for all 2G bands (see Table 2), with output power and characteristics according to 3GPP TS 51.010-1 [16]. TOBY-L2 series modules 2G receiver characteristics are compliant to 3GPP TS 51.010-1 [16], with conducted receiver sensitivity performance described in Table 17. Parameter Min. Receiver input sensitivity GSM 850 / E-GSM 900 Receiver input sensitivity DCS 1800 / PCS 1900 Typical Unit Remarks –110.0 Max. dBm Downlink RF level @ BER Class II < 2.4 % –109.0 dBm Downlink RF level @ BER Class II < 2.4 % Condition: 50 source, other settings as per 3GPP TS 51.010-1 [16] Table 17: 2G receiver sensitivity performance 4.2.7 ANT_DET pin Antenna detection (ANT_DET) is not supported by “00”, “01” and “50” product versions. Pin Name Parameter ANT_DET Output DC current pulse value Output DC current pulse time length Min. Typical Max. Unit Remarks 26 µA 3.6 ms Generated by means of the AT+UANTR command Generated by means of the AT+UANTR command Table 18: ANT_DET pin characteristics UBX-13004573 - R07 Objective Specification Electrical specifications Page 30 of 47 TOBY-L2 series - Data Sheet 4.2.8 PWR_ON pin Pin Name Parameter PWR_ON Internal supply for Power-On Input Signal Min. Max. 3.8 Low-level input High-level input 0.7*VCC Pull-up resistance 35 Low-level input current PWR_ON low time Typical Unit Remarks Module supply input (VCC) 0.3*VCC VCC 50 k –76 µA Internal active pull-up to VCC ms Low time to switch-on the module Unit Remarks Module supply input (VCC) Table 19: PWR_ON pin characteristics 4.2.9 RESET_N pin Pin Name Parameter RESET_N Internal supply for External Reset Input Signal Min. Max. 3.8 Low-level input High-level input 0.7*VCC Pull-up resistance 35 Low-level input current RESET_N low time Typical 0.3*VCC VCC 50 k –76 Internal active pull-up to VCC µA 18 800 ms Low time to switch-on the module 2.1 15 Low time to reset the module Low time to switch-off the module 16 Table 20: RESET_N pin characteristics UBX-13004573 - R07 Objective Specification Electrical specifications Page 31 of 47 TOBY-L2 series - Data Sheet 4.2.10 SIM pins The SIM pins are a dedicated interface to the external SIM card/chip. The electrical characteristics fulfill regulatory specification requirements. The values in Table 21 are for information only. Parameter Min. Low-level input High-level input Max. Unit Remarks –0.30 0.63 VSIM = 1.8 V –0.30 0.80 VSIM = 3.0 V 1.17 2.10 VSIM = 1.8 V 2.00 3.30 VSIM = 3.0 V 0.00 0.45 VSIM = 1.8 V, Max value at IOL = +2.0 mA 0.00 0.40 VSIM = 3.0 V, Max value at IOL = +2.0 mA Low-level output High-level output Input / Output leakage current Typical 1.35 1.80 VSIM = 1.8 V, Min value at IOH = –2.0 mA 2.60 2.90 VSIM = 3.0 V, Min value at IOH = –2.0 mA nA 0 V < VIN < 0.63 V or 1.17 V < VIN < 2.10 V 0 V < VIN < 0.80 V or 2.00 V < VIN < 3.30 V –500 500 Clock frequency on SIM_CLK 3.25 MHz Internal pull-up resistor on SIM_IO 4.7 k Internal pull-up to VSIM supply Table 21: SIM pins characteristics 4.2.11 USB pins USB data lines (USB_D+ / USB_D–) are compliant to the USB 2.0 high-speed specification. See the Universal Serial Bus Revision 2.0 specification [18] for detailed electrical characteristics. Parameter Min. Typical Max. Unit VUSB_DET pin, High-level input 4.40 5.00 5.25 VUSB_DET pin, Low-level input 0.00 1.30 VUSB_DET pin, Current sink 100 Remarks µA High-speed squelch detection threshold (input differential signal amplitude) 100 150 mV High speed disconnect detection threshold (input differential signal amplitude) 525 625 mV High-speed data signaling input common mode voltage range –50 500 mV High-speed idle output level –10 10 mV High-speed data signaling output high level 360 440 mV High-speed data signaling output low level –10 10 mV Chirp J level (output differential voltage) 700 1100 mV Chirp K level (output differential voltage) –900 –500 mV Table 22: USB pins characteristics UBX-13004573 - R07 Objective Specification Electrical specifications Page 32 of 47 TOBY-L2 series - Data Sheet 4.2.12 Generic Digital Interfaces pins Parameter Min Internal supply for GDI domain Typical Max 1.80 Unit Remarks Digital I/O Interfaces supply (V_INT) Low-level input –0.30 0.63 High-level input 1.17 2.10 0.45 Max value at IOL = +2.0 mA Min value at IOH = –2.0 mA Low-level output 0.00 High-level output 1.35 Input/output leakage current –500 500 nA 0 V < VIN < 0.63 V or 1.17 V < VIN < 2.10 V Internal active pull-up resistance 30 130 k Pull-Up class H 30 180 k Pull-Up class M 30 150 k Pull-Down class H 30 180 k Pull-Down class M Internal active pull-down resistance 1.80 Table 23: GDI pin characteristics 4.2.13 DDC (I2C) pins The DDC (I C) interface is not supported by “00”, “01” and “50” product versions. DDC (I C) lines (SCL and SDA) are compliant to the I C-bus standard mode specification. See the I C-Bus Specification [19] for detailed electrical characteristics. Parameter Min Internal supply for GDI domain –0.30 High-level input 1.17 Low-level output Clock frequency on SCL Max 1.80 Low-level input Input/output leakage current Typical 0.00 –500 100 Unit Remarks Digital I/O Interfaces supply (V_INT) 0.63 2.10 0.45 Max value at IOL = +2.0 mA 500 nA 0 V < VIN < 0.63 V or 1.17 V < VIN < 2.10 V kHz Table 24: DDC (I2C) pins characteristics UBX-13004573 - R07 Objective Specification Electrical specifications Page 33 of 47 TOBY-L2 series - Data Sheet 4.3 Parameters for ATEX applications This section provides useful parameters and information to integrate TOBY-L2 series modules in applications intended for use in areas with potentially explosive atmospheres (ATEX), describing: Total internal capacitance and inductance of TOBY-L2 series modules (see Table 25) Maximum RF output power and voltage at the antenna pin of TOBY-L2 series modules (see Table 26) Any specific applicable requirement for the implementation of the apparatus integrating TOBY-L2 series modules, intended for use in potentially explosive atmospheres, must be fulfilled according to the exact applicable standards: check the detailed requisites on the pertinent normative for the application, as for example the IEC 60079-0 [20], IEC 60079-11 [21], IEC 60079-26 [22] standards. The certification of the application device that integrates a TOBY-L2 series module and the compliance of the application device with all the applicable certification schemes, directives and standards required for use in potentially explosive atmospheres are the sole responsibility of the application device manufacturer. Table 25 describes the maximum total internal capacitance and the maximum total internal inductance, considering internal parts tolerance, provided by TOBY-L2 series modules. Module Parameter Description Value Unit TOBY-L200, TOBY-L201 Ci Maximum total internal capacitance 267 µF Li Maximum total internal inductance 12.8 µH TOBY-L210, TOBY-L280 Ci Li Maximum total internal capacitance Maximum total internal inductance 267 12.9 µF µH Table 25: TOBY-L2 series maximum total internal capacitance and maximum total internal inductance Table 26 describes the maximum RF output power transmitted by TOBY-L2 series modules from the primary antenna (ANT1) pin as Power Class 4 Mobile Stations for GSM 850 / E-GSM 900 bands, and the corresponding maximum voltage into a 50 system load. Module Parameter Description Value Unit All ANT1 Pout Maximum RF output power from ANT1 pin 35.0 dBm ANT1 Vout on 50 Maximum voltage from ANT1 pin into a 50 system load 12.6 Vrms Table 26: TOBY-L2 series maximum RF output power and corresponding maximum voltage into a 50 load The TOBY-L2 series modules do not contain internal blocks which increase the input voltage (e.g. like step-up, duplicators, boosters, etc.) except for the primary antenna (ANT1) pin which maximum RF output power and corresponding maximum voltage into a 50 system is illustrated in Table 26. UBX-13004573 - R07 Objective Specification Electrical specifications Page 34 of 47 TOBY-L2 series - Data Sheet 5 Mechanical specifications Pin 1 Indicator M1 M1 M2 M1 M1 M3 P2 P3 P1 J1 J1 J1 J2 H2 ANT2 pin J2 H2 J1 H1 J2 H2 ANT1 pin J2 H2 H1 H1 H1 J1 Figure 3: TOBY-L2 series dimensions (Bottom and Sides views) Parameter Description H1 H2 J1 J2 M1 M2 M3 P1 P2 P3 Weight Module Height [mm] Module Width [mm] Module Thickness [mm] Horizontal Edge to Lateral Pin Pitch [mm] Vertical Edge to Lateral Pin Pitch [mm] Edge to Lateral Pin Pitch [mm] Lateral Pin to Pin Pitch [mm] Lateral Pin Height [mm] Lateral Pin close to ANT1 and ANT2 Height [mm] Lateral Pin Width [mm] Lateral Pin to Pin Distance [mm] Lateral Pin to Pin close to ANT Distance [mm] Horizontal Edge to Central Pin Pitch [mm] Vertical Edge to Central Pin Pitch [mm] Central Pin to Pin Horizontal Pitch [mm] Central Pin to Pin Horizontal Pitch [mm] Central Pin to Pin Horizontal Pitch [mm] Central Pin to Pin Vertical Pitch [mm] Central Pin Height and Width [mm] Horizontal Edge to Corner Pin Pitch [mm] Horizontal Edge to Corner Pin Pitch [mm] Horizontal Edge to Corner Pin Pitch [mm] Module Weight [g] Typical 35.6 24.8 2.6 2.4 2.25 1.45 1.1 0.8 0.9 1.5 0.3 0.2 3.15 7.15 1.8 5.2 4.5 2.1 1.1 1.1 1.25 2.85 <7 Tolerance (1401.6 mil) (976.4 mil) (102.4 mil) (94.5 mil) (88.6 mil) (57.1 mil) (43.3 mil) (31.5 mil) (35.4 mil) (59.1 mil) (11.8 mil) (7.9 mil) (124.0 mil) (281.5 mil) (70.9 mil) (204.7 mil) (177.2 mil) (82.7 mil) (43.3 mil) (43.3 mil) (49.2 mil) (112.2 mil) +0.20/–0.20 +0.20/–0.20 +0.27/–0.17 +0.20/–0.20 +0.20/–0.20 +0.20/–0.20 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.20/–0.20 +0.20/–0.20 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.02/–0.02 +0.20/–0.20 +0.20/–0.20 +0.20/–0.20 (+7.9/–7.9 mil) (+7.9/–7.9 mil) (+10.6/–6.7 mil) (+7.9/–7.9 mil) (+7.9/–7.9 mil) (+7.9/–7.9 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+7.9/–7.9 mil) (+7.9/–7.9 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+0.8/–0.8 mil) (+7.9/–7.9 mil) (+7.9/–7.9 mil) (+7.9/–7.9 mil) Table 27: TOBY-L2 series dimensions UBX-13004573 - R07 Objective Specification Mechanical specifications Page 35 of 47 TOBY-L2 series - Data Sheet 6 Qualification and approvals 6.1 Reliability tests Tests for product family qualifications according to ISO 16750 “Road vehicles - Environmental conditions and testing for electrical and electronic equipment“, and appropriate standards. 6.2 Approvals Products marked with this lead-free symbol on the product label comply with the "Directive 2002/95/EC of the European Parliament and the Council on the Restriction of Use of certain Hazardous Substances in Electrical and Electronic Equipment" (RoHS). TOBY-L2 series modules are RoHS compliant. No natural rubbers, hygroscopic materials, or materials containing asbestos are employed. Table 28 summarizes the main approvals for TOBY-L2 series modules. Directive / Standard / Regulatory / Operator TOBY-L200 TOBY-L201 TOBY-L210 TOBY-L280 GCF (Global Certification Forum) YES YES YES YES PTCRB (PCS Type Certification Review Board) YES YES YES YES YES YES YES YES 1588 YES 1588 1588 YES 1588 1588 YES 1588 1588 YES 1588 YES XPYTOBYL200 YES 8595A-TOBYL200 YES YES XPYTOBYL201 YES 8595A-TOBYL201 YES XPYTOBYL210 YES 8595A-TOBYL210 YES XPYTOBYL280 YES 8595A-TOBYL280 R&TTE (Radio and Telecommunications Terminal Equipment EU Directive) Notified Body number CE (Conformité Européenne) Notified Body number FCC (US Federal Communications Commission) FCC identification number IC (Industry Canada) IC certification number Anatel (Brazilian Certification) RCM (Regulatory Compliance Mark Australia) YES YES NCC (National Communications Commission Taiwan) YES YES KC (Korea Certification) Giteki Mark (Japanese Certification) YES YES AT&T (Mobile Network Operator) Verizon (Mobile Network Operator) YES YES YES Table 28: TOBY-L2 series main certification approvals summary For the complete list of approvals and for specific details on all country and network operators’ certifications, see our website www.u-blox.com or please contact the u-blox office or sales representative nearest you. UBX-13004573 - R07 Objective Specification Qualification and approvals Page 36 of 47 TOBY-L2 series - Data Sheet 7 Product handling & soldering 7.1 Packaging TOBY-L2 series modules are delivered as hermetically sealed, reeled tapes to enable efficient production, production lot set-up and tear-down. For more information about packaging, see the u-blox Package Information User Guide [9]. 7.1.1 Reels TOBY-L2 series modules are deliverable in quantities of 150 pieces on a reel. The modules are delivered using the reel Type B described in the Figure 4 and in the u-blox Package Information Guide [9]. Figure 4: TOBY-L2 series modules reel Parameter Specification Reel Type Delivery Quantity 150 Table 29: Reel information for TOBY-L2 series modules Quantities of less than 150 pieces are also available. Contact u-blox for more information. UBX-13004573 - R07 Objective Specification Product handling & soldering Page 37 of 47 TOBY-L2 series - Data Sheet 7.1.2 Tapes Figure 5 shows the position and the orientation of TOBY-L2 modules as they are delivered on the tape, while the Table 30 specifies the tape dimensions. Pin 1 Sprocket hole Feed direction Figure 5: Orientation for TOBY-L2 modules on tape Table 30: TOBY-L2 series modules tape UBX-13004573 - R07 Objective Specification Product handling & soldering Page 38 of 47 TOBY-L2 series - Data Sheet 7.2 Moisture Sensitivity Levels TOBY-L2 series modules are Moisture Sensitive Devices (MSD) in accordance to the IPC/JEDEC specification. The Moisture Sensitivity Level (MSL) relates to the packaging and handling precautions required. TOBY-L2 series modules are rated at MSL level 4. For more information regarding moisture sensitivity levels, labeling, storage and drying see the u-blox Package Information Guide [9]. For MSL standard see IPC/JEDEC J-STD-020 (can be downloaded from www.jedec.org). 7.3 Reflow soldering Reflow profiles are to be selected according to u-blox recommendations (see TOBY-L2 / MPCI-L2 series System Integration Manual [2]). Failure to observe these recommendations can result in severe damage to the device! 7.4 ESD precautions TOBY-L2 series modules contain highly sensitive electronic circuitry and are Electrostatic Sensitive Devices (ESD). Handling TOBY-L2 series modules without proper ESD protection may destroy or damage them permanently. TOBY-L2 series modules are Electrostatic Sensitive Devices (ESD) and require special ESD precautions typically applied to ESD sensitive components. Table 7 reports the maximum ESD ratings of the TOBY-L2 series modules. Proper ESD handling and packaging procedures must be applied throughout the processing, handling and operation of any application that incorporates TOBY-L2 series module. ESD precautions should be implemented on the application board where the module is mounted, as described in the TOBY-L2 / MPCI-L2 series System Integration Manual [2]. Failure to observe these recommendations can result in severe damage to the device! UBX-13004573 - R07 Objective Specification Product handling & soldering Page 39 of 47 TOBY-L2 series - Data Sheet 8 Default settings Item AT Settings Comments USB interface Enabled TOBY-L2 series modules provide by default the following set of USB functions: CDC-ACM for AT command and data RNDIS for Ethernet-over-USB connection The USB can be configured by the AT+UUSBCONF command to select different sets of USB functions available in mutually exclusive way, configuring the active USB profile consisting of a specific set of functions with various capabilities and purposes (for more details, see the TOBY-L2 / MPCI-L2 series System Integration Manual [2] and the u-blox AT Commands Manual [1], +UUSBCONF AT command). Power Saving AT+UPSV=0 Disabled Network registration AT+COPS=0 Self network registration Table 31: Default settings UBX-13004573 - R07 Objective Specification Default settings Page 40 of 47 TOBY-L2 series - Data Sheet 9 Labeling and ordering information 9.1 Product labeling The labels of TOBY-L2 series series modules include important product information as described in this section. Figure 6 illustrates the label of all the TOBY-L2 series modules, and includes: u-blox logo, production lot, Pb-free marking, product type number, IMEI number, certification numbers, CE marking with the Notified Body number, and production country. 1588 Figure 6: TOBY-L2 series module label 9.2 Explanation of codes Three different product code formats are used. The Product Name is used in documentation such as this data sheet and identifies all the u-blox products, independent of packaging and quality grade. The Ordering Code includes options and quality, while the Type Number includes the hardware and firmware versions. Table 32 details these 3 different formats: Format Structure Product Name TOBY-TGVV Ordering Code TOBY-TGVV-TTQ Type Number TOBY-TGVV-TTQ-XX Table 32: Product Code Formats Table 33 explains the parts of the product code. UBX-13004573 - R07 Objective Specification Labeling and ordering information Page 41 of 47 TOBY-L2 series - Data Sheet Code Meaning Example TOBY Form factor TOBY TG Platform (Technology and Generation) Technology: G:GSM; U: HSUPA; L:LTE, C:CDMA 1xRTT; D:EV-DO Generation: 1…9 L2 VV Variant function set based on the same platform [00…99] 00 TT Major product version [00…99] 00 Quality grade S = professional A = automotive XX Minor product version (not relevant for certification) Default value is 00 Table 33: Part identification code 9.3 Ordering information Ordering No. Product TOBY-L200-00S LTE bands 2 / 4 / 5 / 7 / 17, DC-HSPA+ bands 1 / 2 / 4 / 5 / 8, (E)GPRS bands 850 / 900 / 1800 / 1900 module, mainly designed for operation in America, 35.6 x 24.8 x 2.6 mm, 150 pcs/reel TOBY-L200-50S LTE bands 2 / 4 / 5 / 7 / 17, DC-HSPA+ bands 1 / 2 / 4 / 5 / 8, (E)GPRS bands 850 / 900 / 1800 / 1900 module, mainly designed for operation in America, supporting UART and SDIO interfaces, 35.6 x 24.8 x 2.6 mm, 150 pcs/reel TOBY-L201-01S LTE bands 2 / 4 / 5 / 13 / 17, DC-HSPA+ bands 2 / 5 module, mainly designed for operation in America, supporting UART and embedded TCP/UDP, HTTP/FTP, 35.6 x 24.8 x 2.6 mm, 150 pcs/reel TOBY-L210-00S LTE bands 1 / 3 / 5 / 7 / 8 / 20, DC-HSPA+ bands 1 / 2 / 5 / 8, (E)GPRS bands 850 / 900 / 1800 / 1900 module, mainly designed for operation in Europe, Asia and other countries, 35.6 x 24.8 x 2.6 mm, 150 pcs/reel TOBY-L210-50S LTE bands 1 / 3 / 5 / 7 / 8 / 20, DC-HSPA+ bands 1 / 2 / 5 / 8, (E)GPRS bands 850 / 900 / 1800 / 1900 module, mainly designed for operation in Europe, Asia and other countries, supporting UART and SDIO interfaces, 35.6 x 24.8 x 2.6 mm, 150 pcs/reel TOBY-L280-00S LTE bands 1 / 3 / 5 / 7 / 8 / 28, DC-HSPA+ bands 1 / 2 / 5 / 8, (E)GPRS bands 850 / 900 / 1800 / 1900 module, mainly designed for operation in South East-Asia and Oceania, supporting UART, 35.6 x 24.8 x 2.6 mm, 150 pcs/reel Table 34: Product ordering codes UBX-13004573 - R07 Objective Specification Labeling and ordering information Page 42 of 47 TOBY-L2 series - Data Sheet Appendix A Glossary Name Definition 16QAM 16 Quadrature Amplitude Modulation 8-PSK 8 Phase-Shift Keying modulation ACM Abstract Control Model ADC Analog to Digital Converter BER Bit Error Rate CDC Communications Device Class CSFB Circuit Switched Fall-Back DDC Display Data Channel (I2C compatible) Interface DL Down-link (Reception) DRX Discontinuous Reception ECM Ethernet networking Control Model EDGE Enhanced Data rates for GSM Evolution ERS External Reset Input Signal ESD Electrostatic Discharge FOAT Firmware update Over AT commands FOTA Firmware update Over The Air FW Firmware GDI Generic Digital Interfaces (power domain) GMSK Gaussian Minimum-Shift Keying modulation GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPS Global Positioning System GSM Global System for Mobile Communication High HSDPA High Speed Downlink Packet Access HSIC High Speed Inter Chip HSUPA High Speed Uplink Packet Access Input (means that this is an input port of the module) I2C Inter-Integrated Circuit Interface I2S Inter-IC Sound Interface IMEI International Mobile Equipment Identity IMS IP Multimedia Subsystem Low LGA Land Grid Array LTE Long Term Evolution MBIM Mobile Broadband Interface Model MIMO Multi-Input Multi-Output N/A Not Applicable NCM Network Control Model Output (means that this is an output port of the module) OD Open Drain PCN / IN Product Change Notification / Information Note PD Pull-Down UBX-13004573 - R07 Objective Specification Appendix Page 43 of 47 TOBY-L2 series - Data Sheet Name Definition POS Power-On Input Signal PU Pull-Up QPSK Quadrature Phase-Shift Keying modulation RMC Reference Measurement Channel RMII Reduced Media Independent Interface RNDIS Remote Network Driver Interface Specification SDIO Secure Digital Input Output SIM Subscriber Identity Module Tristate TBD To Be Defined UART Universal Asynchronous Receiver-Transmitter serial interface UL Up-link (Transmission) UMTS Universal Mobile Telecommunications System USB Universal Serial Bus VoLTE Voice over LTE Table 35: Explanation of abbreviations and terms used UBX-13004573 - R07 Objective Specification Appendix Page 44 of 47 TOBY-L2 series - Data Sheet Related documents [1] [2] u-blox AT Commands Manual, Docu No UBX-13002752 u-blox TOBY-L2 / MPCI-L2 series System Integration Manual, Docu No UBX-13004618 [3] u-blox Android RIL Production delivery Application note, Docu No UBX-13002041 [4] [5] u-blox Windows Embedded RIL Production delivery Application note, Docu No UBX-13002043 u-blox GNSS Implementation Application Note, Docu No UBX-13001849 [6] u-blox Mux Implementation Application Note, Docu No UBX-13001887 [7] [8] u-blox GNSS Implementation Application Note, Docu No UBX-13001849 u-blox Wi-Fi / Cellular Integration Application Note, Docu No UBX-14003264 [9] u-blox Package Information User Guide, Docu No UBX-14001652 [10] [11] 3GPP TS 27.007 - AT command set for User Equipment (UE) 3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) [12] [13] 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol 3GPP TS 26.267 - Technical Specification Group Services and System Aspects; eCall Data Transfer; In-band modem solution; General description [14] 3GPP TS 36.521-1 - Evolved Universal Terrestrial Radio Access; User Equipment conformance specification; Radio transmission and reception; Part 1: Conformance Testing [15] 3GPP TS 34.121-1 - User Equipment conformance specification; Radio transmission and reception (FDD); Part 1: Conformance specification 3GPP TS 51.010-1 - Mobile Station conformance specification; Part 1: Conformance specification [16] [17] [18] [19] ITU-T Recommendation V24, 02-2000. List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Connection Equipment (DCE) Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/usb20_docs/ [20] I C-bus specification and user manual - Rev. 5 - 9 October 2012 - NXP Semiconductors, http://www.nxp.com/documents/user_manual/UM10204.pdf IEC 60079-0 - Explosive atmospheres, Part 0: Equipment general requirements [21] IEC 60079-11 - Explosive atmospheres, Part 11: Equipment protection by intrinsic safety 'i' [22] IEC 60079-26 - Explosive atmospheres, Part 26: Equipment with EPL Ga For regular updates to u-blox documentation and to receive product change notifications please register on our homepage (www.u-blox.com). UBX-13004573 - R07 Objective Specification Related documents Page 45 of 47 TOBY-L2 series - Data Sheet Revision history Revision Date Name Status / Comments R01 02-Dec-2013 jpod / sses Initial release R02 23-Jul-2014 sses Advance Information document status Updated module pin 4 definition: VUSB_DET instead of RSVD; Updated UART, GPIOs and SIM detection support; Updated receiver sensitivity performance; Updated VCC current consumption; Updated PWR_ON and RESET_N timings characteristics R03 30-Sep-2014 sses Added and updated minor electrical characteristics R04 28-Nov-2014 sses Early Production Information document status Updated VUSB_DET description: the VUSB_DET functionality is not supported, and the pin should be left unconnected or it should not be driven high Added and updated minor electrical characteristics R05 30-Jan-2015 sses Added description of TOBY-L2xx-50S modules – the “50” product version. Updated UART, SDIO, GPIO sections and added consumption figures with USB not connected. R06 04-Mar-2015 sfal Extended the document applicability to TOBY-L201-01S and TOBY-L280-00S R07 08-Apr-2015 sses Corrected UART supported functionalities description. Added current consumption figures with module in low power idle-mode. UBX-13004573 - R07 Objective Specification Revision history Page 46 of 47 TOBY-L2 series - Data Sheet Contact For complete contact information visit us at www.u-blox.com u-blox Offices North, Central and South America u-blox America, Inc. Phone: E-mail: +1 703 483 3180 info_us@u-blox.com Regional Office West Coast: Phone: +1 408 573 3640 E-mail: info_us@u-blox.com Headquarters Europe, Middle East, Africa Asia, Australia, Pacific u-blox AG Phone: E-mail: Support: Phone: E-mail: Support: +41 44 722 74 44 info@u-blox.com support@u-blox.com Technical Support: Phone: +1 703 483 3185 E-mail: support_us@u-blox.com u-blox Singapore Pte. Ltd. +65 6734 3811 info_ap@u-blox.com support_ap@u-blox.com Regional Office Australia: Phone: +61 2 8448 2016 E-mail: info_anz@u-blox.com Support: support_ap@u-blox.com Regional Office China (Beijing): Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shenzhen): Phone: +86 755 8627 1083 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office India: Phone: +91 959 1302 450 E-mail: info_in@u-blox.com Support: support_in@u-blox.com Regional Office Japan: Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: +82 2 542 0861 E-mail: info_kr@u-blox.com Support: support_kr@u-blox.com Regional Office Taiwan: Phone: +886 2 2657 1090 E-mail: info_tw@u-blox.com Support: support_tw@u-blox.com UBX-13004573 - R07 Objective Specification Contact Page 47 of 47
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 47 Language : it-IT Tagged PDF : Yes Title : TOBY-L2 series Subject : Data Sheet Creator : Microsoft® Office Word 2007 Create Date : 2015:04:13 16:18:47+02:00 Modify Date : 2015:04:13 16:18:47+02:00 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools