Honeywell orporated DR4201 DIGITAL KEY READER User Manual Digireader
Honeywell International Incorporated DIGITAL KEY READER Digireader
USERS MANUAL
DigiReader Series INTRODUCTION The DigiReader DR4200 Series Digital Proximity Readers (DigiReaders) are security devices that reads digital credentials at ranges from 1 to 36 inches (2½ to 91 cm) depending upon the model and the environmental conditions. DR4200 Series DigiReaders are bi-directional, so that a credential can be read from either side of the sensor. DR4200 Series DigiReaders are used with the NexSentry 4100 Family, SE818SC and SE422 ACUs operating as stand-alone devices or in conjunction with a NexSentry Manager, an SE6000 (a NexSentry Command Center NSCC) or an SE5850, (WSE access control host systems). Connection between DigiReaders and an ACU is over the WSE proprietary S-Net interface or over a Wiegand interface to a Wiegand ACU. The Wiegand data can be either 26- or 34-bit Wiegand standard. CAUTION 1. Read this manual carefully before attempting to wire in place a DR4200 Series DigiReader. The warranty is void if damage occurs to the unit as a result of incorrect wiring. CAUTION 2. The information in this manual is not intended to conflict with the building codes, electrical codes, fire codes, or safety codes required for any given installation. In all cases, the prevailing building codes must take precedence. P/N 6600025, REV. BX DigiReader Series GENERAL SPECIFICATIONS D R4201 D R4203 Lowest cost/ smallest reader for 'li ght swi tch' type mounti ngs D escri pti on D R4205 Seri es * D i gi tal proxi mi ty reader for door mulli ons D R4226 D R4238 D i gi tal proxi mi ty reader wi th i ncreased read range D i fferent desi gns and mounti ngs wi thi n seri es * D i gi tal proxi mi ty reader wi th maxi mum read range D i mensi ons (Inches) 1.8 x 0.7 x 0.2 1.8 x 7.5 x 1.2 17.8 x 9.0 x 1.3 25.9 x 13.8 x 1.9 D i mensi ons (C m.) 4.5 x 1.8 x 0.5 4.5 x 19.0 x 3.0 45.2 x 22.9 x 3.2 65.8 x 35.0 x 4.8 Transmi t Frequency 140Khz, full duplex operati on Recei ver Frequency 70kHz Recei ver D emodulati on Phase-Shi ft Key (PSK) si gnal C ard Read C ycle 100 msec Power Source 16 - 24 VD C , less than 80mA Powered vi a 16 - 24 VD C , 0.6 amp nomi nal 16 - 24 VD C , 0.7 amp nomi nal S-net twi sted pai r wi re Power D i ssi pati on Less than 2 watts Less than 17 watts C ontrollers NexSentry 4100 Seri es, Alto 818SC , SE 422 Interface to controller D ual twi sted pai r (22 AWG, shi elded), RS-485;S-Net communi cati ons Indi cators Si ngle tri -color (green-yellow-red), programmable Tamper Protecti on Yes Humi di ty Temperature (°F) Temperature (°C ) Envi ronment 10% to 90% (non-condensi ng) 10% to 90% condensi ng 10% to 90% condensi ng -31 to 150 -31 to 150 -4 to 140 -35 to 66 -35 to 66 -20 to 60 Indoor use only Indoor/Outdoor use Indoor and Outdoor use Wei ght (Lbs.) 0.25 <1 <5 < 10 Wei ght (Kgrams) 0.112 < 0.45 < 2.3 < 4.5 AD A compli ant Yes; Speci al features for easi ng di sabled access i nclude: hands-free access, audi ble and vi sual i ndi cators to i ndi cate access status Max. Read Range D R4201 D R4203 D R4205 D R4226 D R4238 (Uni ts) (Inches) (C m.) (Inches) (C m.) (Inches) (C m.) (Inches) (C m.) (Inches) (C m.) QuadraKey up to 1.5 up to 3.8 up to 3 up to 7.6 up to 4 up to 10 up to 13 up to 33 up to 22 up to 55 NexKey up to 1.5 up to 3.8 up to 3 up to 7.6 up to 4 up to 10 up to 13 up to 33 up to 22 up to 55 D uraKey up to 1.5 up to 3.8 up to 4 up to 10 up to 6 up to 15 up to 22 up to 55 up to 36 up to 91 KeyMate up to 1 up to 2.5 up to 1 up to 2.5 up to 2 up to 5 up to 12 up to 30 up to 15 up to 38 up to 1 up to 2.5 up to 1 up to 2.5 up to 2 up to 5 up to 10 up to 25 up to 15 up to 38 D uraTag Maxi mum read range may vary dependi ng on physi cal envi ronment of i nstallati on. *See Table 1A for details on DR4205 Readers Table 1: Digital Reader Specifications P/N 6600025, REV. BX DigiReader Series DR 4205 SERIES SPECIFICATIONS D R4205 D escri pti on D i gi tal proxi mi ty reader D R4205E D i gi tal proxi mi ty reader for external use D i mensi ons 5.3" x 5.74" x 1.27" Transmi t Frequency 140Khz, full duplex operati on Recei ver Frequency 70kHz Recei ver D emodulati on Phase-Shi ft Key (PSK) si gnal D R4205K D i gi tal proxi mi ty reader wi th capabi li ty of bei ng glass mounted D R4205W D i gi tal proxi mi ty reader wi th i ntegrated waterproof keypad for i ndoor and outdoor use D R4205WE Wi egand proxi mi ty reader for external use Wi egand proxi mi ty reader D R4205WGM Wi egand proxi mi ty reader wi th capabi li ty of bei ng glass mounted (13.5 x 14.6 x 3.2 cm) C ard Read C ycle 100 msec Power Source 16 - 24 VD C , less than 80mA Powered vi a D R4205GM 8 - 24 VD C , less than 80mA S-net twi sted pai r wi re Power D i ssi pati on Less than 2 watts C ontrollers NexSentry 4100 Seri es, Alto 818SC , SE 422 NexSentry 4100 Seri es. NexSentry Wi egand Interface Uni t Req'd Interface to controller D ual twi sted pai r (22 AWG, shi elded), RS-485;S-Net communi cati ons D ual Twi sted pai r (22 AWG, shi elded), RS485; S-Net communi cati ons; 26- or 34-bi t 5wi re Wi egand standard; NexSentry Wi egand Interface Uni t requi red Indi cators Si ngle tri -color, programmable Tamper Protecti on Yes 0% to 90% condensi ng 5% to 100% condensi ng 10% to 90% condensi ng 5% to 100% condensi ng 10% to 90% condensi ng 5% to 90% condensi ng 10% to 90% condensi ng Temperature (°F) 19 to 150 -31 to 150 19 to 150 -31 to 150 19 to 150 -31 to 150 19 to 150 Temperature (°C ) -7 to 66 -35 to 66 -7 to 66 -35 to 66 -7 to 66 -35 to 66 -7 to 66 Indoor use only Weatheri zed and splashproof for outdoor use Indoor use only Weatheri zed and splashproof for outdoor use Indoor use only Weatheri zed and splashproof for outdoor use Indoor use only Humi di ty Envi ronment Wei ght (Ounces) 15 24 19 15 12 24 19 Wei ght (Grams) 420 672 532 420 340 672 532 AD A compli ant Yes; Speci al features for easi ng di sabled access i nclude: hands-free access, audi ble and vi sual i ndi cators to i ndi cate access status Maxi mum Read Range All D R4205 Models (Uni ts) (Inches) QuadraKey up to 4 (C enti meters) up to 10 NexKey up to 4 up to 10 D uraKey up to 6 up to 15 KeyMate up to 2 up to 5 D uraTag up to 2 up to 5 Table 1A: DR4205 Series Specifications P/N 6600025, REV. BX DigiReader Series BASIC OPERATION DigiReaders emit a low-level 140-kHz field. When a digital credential card is placed in this field, a digital chip embedded in the key uses the field’s energy to become activated. Once activated, the key responds by broadcasting a 70-kHz signal, modulated with a key-specific code sequence, back to the reader. The reader receives this signal and converts it to a digital code which is then sent to the Controller. The Controller identifies the digital credential according to its code and makes either an access granted or an access denied decision. DR4205K (/W) has a keypad on the face of the DigiReader. The key pad is used to enter the user’s Personal Identification Number (PIN). (See the appropriate Controller or security management system manual for details on PIN assignment.) The user may enter his or her own PIN. The LED turns amber, and then the user presents a digital credential; or the user may first present the key, the LED turns amber, and then the user enters the PIN. The time allotted for this procedure is defined by the PIN GRACE PERIOD which is set with the Controller SYSTEM command. (See the appropriate Controller or security management system manual for information on setting this parameter.) If an error is made in entering the PIN, the user may press the "*" key to clear the keypad and begin entry again. The keypad versions can be configured for keypad-only use or credential-only use. Refer to your controller manual or security management system manual for details on setup and configuration. DR4200K is just the keypad part of the DR4205K. LED OPERATION LED (S-NET OPERATION) When the DigiReader is on line, the LED is red during the ready state. The TUNE command is used to specify LED and beeper behavior when a valid key is presented. An equivalent of the tune command may be found in each WSE security management system system. DigiReaders have a single three-color LED that can be controlled by the Controller. If power is applied to the unit when not connected to a Controller, or improperly configured at the Controller, the LED acts as follows: Flashes red four times in four seconds, changes to steady amber for four seconds and then turns off for 52 seconds. When a key is presented, the sensor beeps four times, and the LED flashes amber until the key is moved out of range. The flashing red, steady amber, off cycle then resumes and repeats indefinitely while power is supplied. P/N 6600025, REV. BX DigiReader Series LED (WIEGAND OPERATION) The LED is controlled to be red or green by the level of the Wiegand LED control input. 120-OHM TERMINATION JUMPER The internal jumper places 120 ohms of resistance between Data A and Data B for proper end-ofline termination. Install the jumper only if the DR4200 Series DigiReader is the last device on the cable. If you are using: 5 HDG H U 7HUP LQ DWLR Q -X P S HU ' 5 . ' 5 ' 5 ' 5 ( ' 5 : ' 5 *0 ' 5 . ' 5 ) 0 : ' 5 : Table 2: Termination Jumpers If you are using the DR4208, DR4226 or DR4238, an external 120 ohm, 1/4 watt resistor must be used. There is no internal jumper on these models. The jumper is only available on surface mount technology (SMT) models. INTERNAL INTERFACE CABLE An attached cable provides the connection from the printed-circuit assembly and keyboard to the access control unit wiring on all DigiReaders except for the DR4201, DR4208, DR4226 and the DR4238. The cable is color coded as follows: C OLOR FU N C TION C OMMEN TS Red +16 to +28 VD C Black D C Return (Nomi nal) Green S-Net A For use wi th WSE access control panels Whi te S-Net B For use wi th WSE access control panels Blue D ata 0 For use wi th Wi egand access control panels Orange D ata 1 For use wi th Wi egand access control panels Yellow LE D 0 For use wi th Wi egand access control panels Brown LE D 1 For use wi th Wi egand access control panels Shi eld Si gnal Shi eld Ti e to D C Return when used wi th Wi egand access control panels Table 3: Internal Interface Cable P/N 6600025, REV. BX DigiReader Series DR4201 READER INTERFACE The DR4201 reader is connected into the system for S-Net and Wiegand input and output via an RJ45-telephone-jack-style 8-pin connector J1, located in the bottom left corner of the PC board, as shown in figure 1, and described in table 4, below: Figure 1: DR4201 RJ45 S-Net/Wiegand 8-pin Connector J1 Pin D escription +24 VD C S-Net A S-Net B 24 V Return Shi eld or Wi egand D ata 0 (Strap W2 select) Wi egand D ata 1 Wi egand LED 0 Wi egand LED 1 Table 4: DR4201 RJ45 S-Net/Wiegand Signal Pin Descriptions NOTE: A mating connector is supplied with each DR4201 reader, but a crimping tool (not supplied) is required to crimp the connections. P/N 6600025, REV. BX DigiReader Series RECOMMENDED S-NET CABLE The type of cable used for the S-Net will depend on the total length and the number of devices connected. Table 5 lists WSE recommended cables. MAN U FAC TU R E PH YSIC AL D ESC R IPTION GAU GE D ata and Power < 4000 Ft. Southwest Wi re & C able SW 179/ Gray 2 C onductor: D ata 2 C onductor: Power 22 AWG 16 AWG D ata and Power < 500 Ft. Belden 9552 Belden 1069 2 - Pai r Shi elded 18 AWG 16 AWG D ata Only > 500 Ft. Belden 9841 1- Pai r Shi elded 24 AWG Power Only > 500 Ft. Belden 9341 Belden 1342 Belden 9343 2 C onductor 18 AWG 16 AWG 14 AWG Table 5: Recommended S-Net Cable SWITCHES There are two switches on most DR4200 Series DigiReader printed circuit board, as follows, (refer to Figure 2): • Switch SW1 is used to select between the S-Net or Wiegand operating modes. • Switch SW2 is used to set the S-Net address. The DR4201 reader has a 5-position DIP-switch S1, which combines the functions of the rotary address switches S1 and S2 used by the other DR4200 Series DigiReaders. This is described in the DR4201 ADDRESS DIP-SWITCH section, below. P/N 6600025, REV. BX DigiReader Series DIGIREADER ADDRESS Each DigiReader must have a unique address. SW1 is used to select the special reader modes of operation, (as shown in Table 6). SW1 should be set to 0 for S-Net operation and F for Wiegand operation. SW2 is set in the factory to 1 but may be set to an address between 1 and 15 (F). Valid addresses may be limited by the controller; (see the appropriate controller manual). Figure 2: Address Switch When used with an SE422 controller, addresses 01 and 02 should be assigned to nodes 13/15 and 14/16, respectively. S W1 * (N ormal Mode) S W1 * (P IN /K ey Mode) S W2 4, 5 or 6 4, 5 or 6 4, 5 or 6 4, 5 or 6 8 ** C , D or E ** 0 ** FU N C TION S -Net addresses 1-F hexadeci mal (1-15 deci mal) S -Net address 16 deci mal Wi egand 26-bi t Wi egand 34-bi t D emo Mode RF Test Mode *** Table 6: Valid Switch Settings for Switches 1 and 2 (* See the DR4205K SPECIAL OPERATING FEATURE section, below) (** See next page for S-Net address 16, Normal or PIN/Key explanation) (*** See the TESTING THE DIGIREADER LOCATION section, below) P/N 6600025, REV. BX DigiReader Series DR4205K SPECIAL OPERATING FEATURE The DR4205K reader has two modes of operation, dependent on the setting of address switch SW1, (which sets the upper byte of the address): the Normal Mode (SW1 = 0 or 8), and the PIN/Key Mode (SW1 = 4, 5 or 6 or C, D or E). These two modes are described below. NORMAL MODE Address switch SW1 set to 0, the DR4205K operates in its normal mode. Address switch SW2 is then set to the physical S-Net address of the DR4205K: 1 through 9 and A through F (addresses 1 through 15). In order to address the 16th reader in the normal mode, SW1 = 8 and SW2 = 0. Example: SW1 = 0 and SW2 = 1 to F sets normal mode for nodes #1-15; SW1 = 8 and SW2 = 0 sets normal mode for node #16. Operation in Normal Mode: DKR portion only enabled: the key is sent as a key, and no PIN is expected. VIP portion only enabled: the PIN is sent as a PIN, with the number of PIN digits to be entered set in the SYSTEM command. No key is expected. Both DKR and VIP portions enabled: the key is sent as a key, the PIN is sent as a PIN. Both key and PIN are expected (in either order). The number of PIN digits to be entered is set in the PIN DIGITS entry of the SYSTEM command. PIN/KEY MODE Address switch SW1 set to 4, 5 or 6, the DR4205K operates in its 'PIN/Key' mode, where: either a) the PIN will be sent as a key, or b) the key will be sent as a PIN. The number of digits in the PIN number is determined by the 4, 5 or 6 of switch SW1, and, again, address switch SW2 determines the physical S-Net address of the DR4205K for nodes 1 to 15. In order to address the 16th reader in the PIN/key mode, SW1 = C, D or E and SW2 = 0. NOTE: C = 8 + 4, D = 8 + 5 and E = 8 + 6. Example: SW1-SW2 set as 41, 51 or 61, i.e. SW1 = 4, 5 or 6 and SW2 = 1 set node #1 in 'PIN/ Key' mode, for a 4-, 5- or 6-digit PIN, respectively; similarly for nodes 2 through 15; but for node 16, for a 4-, 5- or 6-digit PIN, SW1-SW2 = C0, D0 or E0, respectively. Operation in PIN/Key Mode: SW1 set to 4, 5, or 6 (or C, D or E): determines the number of PIN digits, 4, 5 or 6, (which must match the number of digits set in the PIN DIGITS entry of the SYSTEM command).. DKR portion only enabled: the key is sent as a PIN. VIP portion only enabled: the PIN is sent as a key. Both DKR and VIP portions enabled: the key is sent as a key, the PIN is sent as a PIN. Both key and PIN are expected (in either order). The number of PIN digits to be entered is set both in SW1 and in the PIN DIGITS entry of the SYSTEM command. (Note that with both the DKR and VIP portions enabled the operation is the same as for the normal mode.) P/N 6600025, REV. BX DigiReader Series DR4201 ADDRESS DIP-SWITCH The DR4201 reader has a single 5-position DIP-switch S1 for address selection, see figure 3, below, which demonstrates S-Net address 1 being selected. Table 7, below, shows the possible addressing selections. ON OFF Figure 3: DR4201 Address DIP-Switch Showing S-Net Address 1 Selected Switch S1 (Settings) S-N et Address Function On Off Off Off Off Off On Off Off Off On On Off Off Off Off Off On Off Off On Off On Off Off Off On On Off Off On On On Off Off Off Off Off On Off On Off Off On Off Off On Off On Off 10 On On Off On Off 11 Off Off On On Off 12 On Off On On Off 13 Off On On On Off 14 On On On On Off 15 Off Off Off Off On 16 Off On Off On On Wi egand Interface (26-bi t) Off Off On On On Wi egand Interface (34-bi t) Off On On On On D EMO Mode On On On On On TEST Mode Table 7: DR4201 Address DIP-Switch Selections 10 P/N 6600025, REV. BX DigiReader Series TAMPER SIGNAL (S-NET ONLY) DR4200 Series DigiReaders send a tamper signal to an S-Net-based Controller each time an address switch (SW1 or SW2, described above) is changed. Note that the DR4208, DR4226 and DR4238 have physical tamper switches. S-NET CONNECTIONS The S-Net is an RS485 serial network for communication between the Controller and node devices. Typically, the cable used is two twisted pairs with an overall shield; one pair is for data, the other pair is for DC power. Terminate the last S-Net device with a 120-ohm, ¼ watt resistor or termination jumper as shown in Figure 2. The maximum S-Net length is 4000 feet (1200 meters). Figure 4: S-Net Wiring S-Net cable should only be installed in a daisy-chained fashion. WSE strongly recommends replacing all crimp lug/soldered splices by daisy-chained connections in and out of each device. (Note that up to two AD4305 NexStar RS485 Multiplexers may be used to simplify wiring and extend a network.) Where a pigtail cable is provided with reader, splices are required and the installer should try to keep the splice within 3 feet of the reader, if possible, to allow splice inspection at the reader location. The type of cable used for the S-Net will depend on the total length and the number of devices connected. Separate twisted-pair cables should be used for data and power when the S-Net exceeds 500 feet (152 meters). See Table 4 for WSE recommended cables. P/N 6600025, REV. BX 11 DigiReader Series WIEGAND CONNECTIONS Refer to the following table for the proper wire size for a particular cable length to use in a DigiReader Wiegand application. (NOTE: For the DR4201, jumper W2 must be in place for Wiegand to be operative.) 6-C ON D U C TOR WIEGAN D C AB LE WITH SH IELD Mi ni mum Wi re Si ze Maxi mum Length 22 AWG 200 F eet 20 AWG 300 F eet 18 AWG 500 F eet Table 8: Recommended Wiegand Cable Gauge Figure 5: Typical Wiegand Connection 12 P/N 6600025, REV. BX DigiReader Series MOUNTING LOCATION (DR4201 READER) The DR 4201 reader is designed to be mounted in a single-gang switch-plate receptacle, attached to the back of a single-gang switch plate cover, as shown in figures 6 and 7, below. Figure 6: DR4201 Front View (Mounted) (The DR 4201 reader'sLED mode indicator is visible through the plastic cover in the upper left corner.) Figure 7: DR4201 Side View (Mounted) P/N 6600025, REV. BX 13 DigiReader Series MOUNTING LOCATION (OTHER READERS) Use care when choosing the installation site. To avoid possible external sources of RF interference, do not locate the unit near motors, pumps, generators, DC-AC converters, AC switching relays, light dimmers, or any other devices that emit an electronic radar frequency. Do not locate the unit within 10 feet (3 m) of a computer terminal. The DR4203 and DR4204 units are the only two readers that are specifically designed to be mounted on metal. Metal in the vicinity of any of the other devices can reduce the read range. In general, as the amount of metal in close proximity to the device increases, the reliable maximum read range decreases. For optimum operation, ensure that DigiReader has a minimum of 6 inches (15 cm) clearance at the rear and surrounding sides, as shown in Figure 4. Never cover the front of the DigiReader with any type of metal. Use the method appropriate to the mounting surface material; if required, use sealing compound to maintain water-resistance. Figure 8: Mounting For Optimum Read Range 14 P/N 6600025, REV. BX DigiReader Series TESTING THE DIGIREADER LOCATION If RF interference is suspected at a particular location, check the site prior to mounting the DigiReader. A DigiReader may respond in one of two ways in the presence of RF interference: • The unit may beep and the LED illuminate with no access credential present. • Credential reads may be inaccurate or slow. Use the following procedure to identify a location and position for DigiReader to minimize interference. 1. Set the DigiReader address switches SW1 and SW2 to FF (test mode). • Connect only the wires which provide power. • Hold the DigiReader against the installation surface. • Without presenting a credential to the reader, listen for beeps indicating RF interference. (Make sure you do not have a credential in your pocket or elsewhere, where it might be detected.) • The greater the number of beeps, the noisier the reader’s environment. 2. Once a quiet (free of RF noise) location has been identified, connect the DATA A and DATA B wires. • Set switches SW1 and SW2 to the correct address. The Controller must also be connected to the S-Net and set up to read credentials. • Present a valid credential to the unit. • Verify that the credential can be read from the expected distance. 3. The DigiReader may again be moved to optimize the read-range. • If trouble persists, verify S-Net wiring and grounding. • Repeat steps 1 and 2 as necessary to identify the optimum installation location. P/N 6600025, REV. BX 15 DigiReader Series GENERAL INSTALLATION See the procedures for the reader model and installation type below for additional instructions. Cable Preparation: 1. Route the data and power cable to the DigiReader location and prepare the cable for attachment to the DigiReader. 2. Remove two inches of the plastic jacket and the shielding foil from the cable. 3. Strip each wire back 1/4" for splicing to the DigiReader. DR4203, DR4205 Series and DR4208 Installation: 1. S-Net cable on DigiReader may be routed from the back, bottom or the side of the DigiReader. The reader is pre-configured for cable installation through the back mounting plate. Note: S-Net cable is routed through the side on DR4205GM Reader only. (See Figures 9 and 14, below). 2. For readers other than DR 4205GM or DR 4203, remove the plastic notch from the bottom of the cover. A rattail file may be used to enlarge the opening (Figure 9). Figure 9: Cable Routing Configurations 16 • Splice the DigiReader interface cable to the controller wiring run according to Table 3. If the DigiReader is the last S-Net device on the S-Net cable run, install the termination jumper as directed on page 5, 120 OHM TERMINATION JUMPER. • Set the address switch, as required. P/N 6600025, REV. BX DigiReader Series DR4226 AND DR4238 INSTALLATION 1. Route the data and power cable to the DigiReader location and prepare the cable for attachment to the DigiReader. 2. Remove two inches of the plastic jacket and the shielding foil from the cable. 3. Strip the wire back 1/4" for insertion into a crimp ring. Tin the stripped and ground wire ends. 4. Slip the Teflon tubing over the shield wire. 5. Use crimp tool to attach the crimp rings to each wire. 6. Make the five connections from the cable to the back of a DR4226 or DR 4238 reader using the panhead screws. If the DigiReader is the last device on the S-Net run, install the termination resistor between the Data A and Data B connections. 7(50,1$/ &200(176 3RZHU WR9'& 3RZHU '&5HWXUQ 'DWD$ 61HW$ 'DWD% 61HW% 5' 1RW8VHG 7' 1RW8VHG 6KLHOG 6LJQDO6KLHOG Table 9: DR4208 / DR4226 / DR4238 Wire Connections 7. Set the address switch, as required. The address switches on the DR4208 are on the inside of the unit. Figure 10: DR4226 / DR4238 Address Switch P/N 6600025, REV. BX 17 DigiReader Series WALL MOUNTING WITH SCREWS • After completing all connections to the DigiReader, weatherize the cable connections by sealing the cable passage with a nonconductive silicone sealant. • Verify the correct address switch settings for proper operation and configuration. DR4203 and DR4205 Series • Mount the reader base to the wall. Use the four WSE-supplied, 1 1/4" Flathead, #6-32 thread screws or other means appropriate to the wall composition. • Put the DigiReader cover in place and secure with the two self-captive screws from the bottom. DR 4205 DR 4203 Figure 11: Securing DR4203 and DR4205 Series Cover 18 P/N 6600025, REV. BX DigiReader Series DR4226 and DR4238 • Mount the reader to the wall using the four WSE-supplied, 1 1/4" flathead, #6-32 thread screws or other means appropriate to the wall composition. • Install the four rubber caps to cover the screw heads on the face of the reader. Figure 12: Mounting DR4226 and DR4238 P/N 6600025, REV. BX 19 DigiReader Series WINDOW MOUNTING DR4205GM This type of mounting is necessary for DR4205GM unit. 1. Clean the window with glass cleaner or isopropyl alcohol and dry thoroughly. 2. Spray or wipe the window with slightly soapy water. 3. While the window is still wet, peel off the paper backing of the decal and press against the wet section of the window and move around to release any air bubbles to assure maximum contact with the window. Wipe dry any extra water coming out from the sides. See Figure 13. 4. Once the reader and decal are in place, it may be necessary to temporarily tape the reader to the window while the adhesive sets. It should take approximately 10 minutes. Figure 13: Placement of Decal and Reader onto Glass 20 P/N 6600025, REV. BX DigiReader Series 5. While the adhesive is setting, follow the general installation instructions on routing the cable through the side channel and addressing the unit. After determining which side the cable will be routed through, drill a hole in that side of the front facia to match the pre-drilled slots in the back panel of the reader. Note: To find exact hole location for drilling, look for a circle of smooth area on the side of the facia, where there is an absence of texture in the lexan material. Reference page 16 for cabling instructions. Also see Figure 14 below. 6. Secure the cover as shown in Figure 14. Figure 14: Routing the Cable and Attaching the Facia 7. After the reader is securely set to the window, remove any masking tape used and clean the window surrounding the reader. P/N 6600025, REV. BX 21 DigiReader Series CONTACTING WSE 22 Telephone: 1-800-227-1667 Monday through Friday 6:00am - 6:00pm (PST) E-mail: WSEHelp@wse.com Web Site: http://www.wse.com P/N 6600025, REV. BX DigiReader Series Name of Manual: Part Number: DigiReader Series: Installation and Operation Manual P/N 6600025 Revision: B Organization: ________________________________________________________________ ________________________________________________________________ Address: ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ OtherEquipment Ordered With Your DigiReader(s): Evaluation of Manual: EXCELLENT NA NA NA NA NA NA NA Were you able / was your integrator able to set up your DigiReader(s) by using this manual? NA Did you have to call Customer Service for help on one or more issues? NA Organization: Content: Style: Thoroughness: Clarity (Words): Clarity (Figures): Clarity (Tables): and/or POOR FAIR ADEQUATE GOOD What additional aid(s) did you use to bring up your equipment? ________________________________________________________________ ________________________________________________________________ Other Comments (Positive): ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ Other Comments (Negative): ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ Please tear off this sheet, fill it out, and return it within 3 months of system installation. P/N 6600025, REV. BX 23 DigiReader Series 24 P/N 6600025, REV. BX
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Page Count : 24 Create Date : 1999:07:29 12:10:36 Producer : Acrobat Distiller 3.01 for Windows Subject : Digireader Author : SESSAD Creator : Adobe PageMaker 6.52 Title : DigireaderEXIF Metadata provided by EXIF.tools