ADC Telecommunications DAS8-4-W In-Building Distributed Antenna System User Manual J bonnie john front cover eps

ADC Telecommunications Inc. In-Building Distributed Antenna System J bonnie john front cover eps

Part 2 Users Manual

4LGCell InstallationThis section describes how to install the LGCell equipment. This section does not describe how to install cables, MBS or other equipment. For pre-installation planning, please see Section 3, LGCell Site Planning and Design.Although modeled after an Ethernet/LAN-like architecture, LGCell is not intended to be connected to Ethernet data hubs, routers, or other similar data equipment.Only LGC Wireless personnel and Service Provider approved vendor personnel are authorized to install the LGCell system. Cellular and PCS equipment operate in frequency bands that are licensed for use by cellular and PCS operators.If you plan to connect your LGCell system to more than one radio or base station, you also need the Integration Module Installation and Reference Manual. ContentsLGCell InstallationSystem Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3LGCell Standard Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5LGCell Equipment Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5•Main Hub Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7•Expansion Hub Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10•Remote Antenna Unit (RAU) Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 13Alarm Report Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4-2 LGCell Installation
4-3System RequirementsAn LGCell system has location, space, power, and safety requirements for installation. The Dual Band LGCell requirements for space and power are different from those for a single-band system and are noted below.System LocationThe LGCell Main Hub and Expansion Hub mount into a standard 19" equipment rack in a wiring, telecom, or electrical closet, which may contain other Ethernet, telephony, or miscellaneous equipment.•Standard wiring closet temperatures: 0-45° C•Does not require special air conditioningSpace RequirementsThe LGCell Main Hub and Expansion Hubs are installed into a standard 19” rack.•The Main Hub height is 1.7” (44.5 mm). The Dual Band Main Hub is 3.5” (88.9 mm) high.•The Expansion Hub height is 1.7” (44.5 mm). The Dual Band Expansion Hub is 3.5” (88.9 mm) high.•Allow at least one inch (25 mm) clearance between each hub, between any existing equipment in the rack, and between the bottom shelf of the rack and the hub.Power RequirementsThe LGCell requires AC voltage/current. LGC Wireless recommends connecting it to a UPS (Uninterruptable Power Supply), which may exist in the wiring closet. Dual-Band equipment requires twice as much power as single-band equipment.•LGCell operates with 88-264 VAC 50/60 Hz.•The Main Hub uses a maximum of 1.6 A of electrical current.•The Expansion Hub uses a maximum of 1.6 A of electrical current.•The RAUs are powered from the Expansion Hubs via the UTP/STP cable and they use 12V DC.
4-4 LGCell InstallationUnderwriters Laboratory Installation GuidelinesUse the following guidelines when rack mounting the LGC Cell:1Do not exceed the maximum ambient air temperature of 45° C during operation. Provide sufficient airflow and cooling within the rack to prevent heat build-up from exceeding this limit.2Be careful when servicing these products. If you are removing the system from the rack, turn it off and remove the power cord first. There are no user serviceable parts inside the hubs or RAUs.3Do not compromise the amount of airflow required for safe operation of the equipment when installing it in a rack. Both the Main Hub and the Expansion Hub draw in air on the left side and exhaust heated air at the rear. The hubs pass approximately 6 cu. ft. of air per minute through themselves and only dissipate a maximum of 25 watts of heat from their internal circuitry.4The AC input current consumption of the hubs is rated at 1.6 A at 110 VAC. The internal power supply has internal fuses that are not user replaceable. Consider the worst-case power consumption shown on the product labels when provisioning the rack’s AC power source and distribution.Fiber Port Safety PrecautionsSuggested safety precautions for working with LGCell Fiber Ports follow. For information about LGCell compliance with safety standards, see Appendix C – Compliance Information.•Viewing fiber: Observe the following warning about viewing fiber ends and ports.Do not stare with unprotected eyes at the connector ends of the fibers or the ports of the hubs. Invisible infrared radiation is present at the front panel of the Main Hub and Expansion Hub. Do not remove the Fiber Port dust cover unless the port is in use. Do not stare directly into a Fiber Port.•Test fiber cables: When you use test fiber optical cables, connect the optical power source last and disconnect it first.•Fiber ends: Cover any unconnected fiber ends with an approved cap. Do not use tape.•Broken fiber cables: Do not stare with unprotected eyes at any broken ends of the fibers. Report any broken fiber cables and have them replaced.•Cleaning: Use only approved methods for cleaning optical fiber connectors.•Modifications: Do not make any unauthorized modifications to this fiber optical system or associated equipment.
4-5•Live work: Live work is permitted on the LGCell as it is a Class 1 hazard.•Signs: No warning signs are required.•Test equipment: Use Class 1 test equipment.Cable and Connector RequirementsThe LGCell equipment operates over standard TIA/EIA 568-A specification, Category 5 (CAT 5), or better, Unshielded Twisted Pair (UTP) or Shielded Twisted Pair (STP) and standard 62.5µm/125µm Multi-Mode Fiber cable (MMF), at a wavelength of 1300 nanometers (nm). These cables are widely used industry standards for Local Area Networks (LANs). The regulations, guidelines, and standards for cable installation are identical to those specified by the TIA/EIA 568-A standard for LANs. See Appendix B – TIA/EIA 568-A Cabling Standard.LGC Wireless recommends Plenum rated CAT 5 UTP/STP and MMF cable and connectors for conformity to building codes and standards.LGCell Standard Equipment•LGCell Main Hub•LGCell Expansion Hub•Remote Antenna Units (RAUs) with an in-building antenna•Four screws for mounting the RAUs•Four rack mount screws per hub to mount hubs into a 19" rack•Installation and Reference GuideLGCell Equipment InstallationThe following are procedures for installing an LGCell system. Pre-testing the system is not required. The installation procedures are based on the following assumptions:•The LGCell equipment has been unpacked and inspected.•Locations for the Main Hub, Expansion Hubs, and RAUs have been identified.•19" rack space is available in the wiring closets.•AC power is available for the LGCell.•MMF and UTP/STP have been pulled into place (based on previous design) and terminated.
4-6 LGCell InstallationLGCell system installation includes the following tasks:•Installing Main Hub•Installing Expansion Hubs•Installing Remote Antenna Units (RAUs) and antennas•Connecting RF cables•Connecting CAT 5 cables•Connecting MMF cables•Optimizing the systemThese procedures tell you how the LGCell should respond during various phases of the installation. If it is not responding as it should, see Section 6, Common Problems, Troubleshooting, and Frequently Asked Questions.Equipment InspectionCheck that all standard equipment was shipped. (See LGCell Standard Equipment, on page 5.) If the equipment is damaged or parts are missing, contact LGC Wireless immediately, at 1-800-530-9960 in the U.S. or, for international customers, at +1-408-487-2400. Most problems during installation are caused by improperly terminated UTP/STP and MMF.LGCell ConfigurationIf you are installing a Dual-Band LGCell system, use the following steps, from here through “RF Cable Connection” on page 16 of this chapter.
4-7This diagram illustrates how the LGCell is configured. The rest of this section contains configuration and installation procedures.Main Hub InstallationYour installation may have one or more Main Hubs, each located in the same or different wiring closet. Use the following procedures for all Main Hubs.1 Mount the Main Hub Mount the Main Hub to the rack in the assigned wiring closet location, using four screws provided.For air circulation, be sure to leave at least one inch (25 mm) space between all hubs and between any other equipment in the rack. If mounting a hub on the rack’s bottom shelf, also leave at least one inch (25 mm) clearance from the bottom.LINKSTATUS1234DOWNLINKSTATUSSYNCUPSYNCPOWERTO EXPANSION HUB PORTSLGC WIRELESSLGCellª Main HubDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUPDOWNSYNCUPAC POWER
4-8 LGCell Installation2 Connect Power and Power UpAfter mounting the Main Hub, connect the AC power cord to the Main Hub. Plug the power cord into an outlet providing AC power (88-264 VAC). See 1 in graphic.Power up the Main Hub by flipping the power switch from position 0 to position 1. See 2 in graphic.The POWER and SYNC LEDs on the front panel should be green (lit).3 Connect the MMF cablesUsing the procedure below, connect all MMF cables (two per port) to the MMF ST-female connectors (labeled DOWN and UP) on the Main Hub front panel. Use any available Main Hub port.
4-9Be sure the MMF cable ST-connectors are clean and free of dust or oils. If the fiber connector front face is not free of dust or oils, follow the manufacturer’s recommendations for cleaning it.The MMF cable is labeled with either 1 or 2, or is color-coded. This distinguishes the connectors for proper connection between the Main Hub and Expansion Hubs.If the fiber jumper is labeled with 1 or 2:•Connect 1 to UP on Main Hub•Connect 1 to UP on Expansion Hub•Connect 2 to DOWN on Main Hub•Connect 2 to DOWN on Expansion HubIf the fiber jumper is color-coded (for example, “blue” or “red”):•Connect “blue” to UP on Main Hub•Connect “blue” to UP on Expansion Hub•Connect “red” to DOWN on Main Hub•Connect “red” to DOWN on Expansion HubThe connections for the Dual Band system are shown here. Make sure you connect the 900 MHz Main Hub to the 900 MHz Expansion Hub and the 1800 MHz hubs together.
4-10 LGCell InstallationBe sure to record which number or color is connected to UP and to DOWN. This information is needed when connecting the other end of the MMF cables to the Expansion Hub ports.Expansion Hub InstallationThe Expansion Hubs may be located in the same or different wiring closets, and they may be located in a different wiring closet than the Main Hub. Use the following procedures for all Expansion Hubs.4 Check Main Hub LEDsThe POWER and SYNC LEDs should be green. If not, reset the Main Hub.If the POWER and SYNC LEDs do not light green, see Section 6, Common Problems, Troubleshooting, and Frequently Asked Questions.The LINK STATUS and SYNC LEDs on the ports where the fiber is connected should be red. This indicates that the other end of the MMF cable is not yet connected to the Expansion Hub ports.
4-111 Mount the Expansion HubsMount the Expansion Hubs onto the rack in the assigned wiring closet location, using four screws per hub.For air circulation, be sure to leave at least one inch (25 mm) space between all hubs and between any other equipment in the rack. If mounting a hub on the rack’s bottom shelf, also leave at least one inch (25 mm) clearance from the bottom.2 Connect Power and Power UpConnect the AC power cord to the Expansion Hub. Plug the power cord into an outlet providing AC power (88-264 VAC). See 1 in graphic.Power up the Expansion Hubs by flipping the power switch from position 0 to position 1. See 2 in graphic. The POWER LED on the Expansion hub should be green (lit).
4-12 LGCell Installation3 Connect the MMF cablesConnect all MMF cables from the Main Hub to the Expansion Hubs. The SYNC LED should be green.For proper connection between the Main Hub ports and the Expansion Hub ports, refer to the numbering or color coding you recorded when installing the Main Hub.4 Check Expansion Hub LEDsConnect all MMF cables from the Main Hub to the Expansion Hubs.The LINK STATUS and SYNC LEDs on each Expansion Hub port should be red when the UTP/STP cable is not yet connected to the RAUs.
4-13Remote Antenna Unit (RAU) Installation5 Connect UTP/STP cables from RAUsConnect all UTP/STP cables coming from the RAUs to any available RJ-45 connector on the Expansion Hub.The Expansion Hub fiber port LINK STATUS and SYNC LEDs should be green or off.The LINK STATUS and SYNC LEDs on each Expansion Hub port should remain red until the RAU is connected on the other end.1 Connect AntennasConnect an accessory antenna to each RAU SMA connector. (The illustration shows the RAU with an optional Rubber Duck antenna.)When connecting to the SMA connector on the antenna, DO NOT over-tighten the connector. Firmly hand-tightening the connector is adequate.TENNA PORTSLGCell™ EDOWNMAIN HUB PORTSUPSYNCPOWERAC POWERANTENNA PORTSLGC WIRELESSLGCell™ Expansion HubLINKSTATUSSYNC
4-14 LGCell Installation2 Mount RAUs and AntennasMount all RAUs in their assigned locations, using the enclosed screws. The RAUs can mount above or below the ceiling, or to a wall.For connecting and mounting an accessory directional antenna, refer to the instructions shipped with that antenna.
4-15The Dual Band RAU mounting is shown below.3 Connect UTP/STP CableConnect the UTP/STP cable coming from the Expansion Hub to the RJ-45 connector on the RAU.
4-16 LGCell InstallationRF Cable ConnectionBefore connecting any cables to the Main Hub, be sure the RF power level does not exceed the input rating for the Main Hub. (See “LGCell System Specifications” on page 16 in Section 2, LGCell Equipment.)For coverage applications, LGC Wireless recommends that you insert a lightning arrestor or surge protector between a roof-mounted antenna and the Main Hub. If you use a repeater, insert the lightning arrestor or surge protector between the repeater and roof-mounted antenna.The following illustration shows how to connect the LGCell for coverage applications, with a repeater.For the Dual Band RAU, connect the 900 MHz Expansion Hub cable to the top connector and the 1800 MHz cable to the bottom connector.4 Check LEDsThe green POWER LED should be on and the red ALARM LED should be off.The green LED indicates that the RAU is receiving power from the Expansion Hub assigned to it.
4-17Duplex ConnectorThis N-type female connector is typically used to connect the LGCell to a repeater, roof-mounted antenna, or MBS, as shown on the previous page.Connect an N-type male RF coaxial cable to the duplex N-type female connector (labeled DUPLEX) on the Main Hub back panel. If an N-type male connectorized RF cable is not available, use an RF adaptor. Connect the other end of the coaxial cable to the roof-mounted antenna, MBS, or repeater.a0721234DOWNLINKSTATUSSYNCUPSYNCPOWERAC POWERTO EXPANSION HUB PORTSLGC WIRELESSLGCell™ Main HubDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUPUplink (Reverse) and Downlink (Forward) -MainHubN-Male to N-Male Coaxial CablesN-Male to N-Male Coaxial CablesRoof-Mounted AntennaSurge SuppressorRepeaterTo Ground ConnectorDuplexOutput
4-18 LGCell InstallationThe duplex ports have a variable gain. Please see the table for system gain under “Maximum Input RF Power per Carrier vs. Number of Carriers” on page 17 in Section 2, LGCell Equipment.Downlink (Forward) and Uplink (Reverse) ConnectorsConnect an N-type male RF coaxial cable to the downlink N-type female connector (labeled FORWARD) and an N-type male RF coaxial cable to the uplink N-type female connector (labeled REVERSE) on the Main Hub back panel.Connect the other ends of the coaxial cable to the MBS. For diagrams of connecting LGCell to specific MBS equipment, see Section 5, Connectivity.For simplex MBSs, be sure the MBS downlink coaxial cable connector plugs into the downlink connector, and the uplink coaxial cable connector plugs into the uplink connector on the Main Hub.Alarm Report MonitorA separately orderable option for use with LGCell, the Alarm Report Monitor is an alarm monitoring, reporting, and remote control system. Up to 255 remote-ARM monitoring units can monitor up to 2,040 LGCell systems. Each remote-ARM unit communicates with the ARM software through a dial-up modem connection, using an external or internal modem. A database of these devices is set up in a PC, with a unique address for each device.The ARM supports multiple users and tracks responsibility through log-in and log-out procedures, using four security levels to protect critical system functions. It features a graphic color status display, remote system reset control, alarm history and control logs, security code management, and journal printer and paging options.For ARM installation instructions, see Appendix E – Alarm Report Monitor (ARM2000).a060DUPLEXFORWARDREVERSE
5ConnectivityThis section describes how to connect multiple LGCell systems and how to connect specific microcellular base stations (MBSs) to the LGCell.Please refer to the tables in Section 2, LGCell Equipment, for important information on system gains and maximum RF power per carrier.ContentsConnectivityConnecting Multiple LGCell Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Connecting two LGCells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Connecting More Than Two LGCells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Connecting LGCell to Base Stations, Microcells, or Picocells . . . . . . . . . . . . . . . 4
5-2 Connectivity
5-3 Connecting Multiple LGCell SystemsConnecting multiple LGCell systems increases the total number of Remote Antenna Units (RAUs). Multiple LGCells can be stacked to increase the total number of RAUs through the use of power combiner/dividers.LGC Wireless provides Integration Modules which may be used with the LGCell to efficiently centralize additional radio capacity inside a facility. These Modules provide the connection between the radios for the facility and the LGCell system. Because the Integration Modules distribute all available radio capacity automatically among all antennas within a cell, available capacity is dynamically allocated throughout the entire coverage area, thus providing an improved grade of service without the need to conduct ongoing traffic monitoring and analysis. Specific installation information on all available Integration Modules may be found in the Integration Module Installation and Reference Manual.Connecting two LGCellsConnecting two LGCells increases the total number of RAUs from 16 to 32. A 2x1 or 2x2 hybrid power combiner/divider is required (see graphic below).a0091234DOWNLINKSTATUSSYNCUPSYNCPOWERAC POWERTO EXPANSION HUB PORTSLGC WIRELESSLGCell™ Main HubDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUP1234DOWNLINKSTATUSSYNCUPSYNCPOWERAC POWERTO EXPANSION HUB PORTSLGC WIRELESSLGCell™ Main HubDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUPDOWNLINKSTATUSSYNCUPMain Hubs2 x 1 Power CombinerN-Female ConnectorsIn Back of MHN-Male to N-MaleCoaxial Jumper Cables (2)N-Male to N-MaleCoaxial Jumper CablesN-Female Connectors (3)To Antenna on Roofor MBS or Repeater
5-4 ConnectivityThe following are procedures for connecting two LGCells. For Dual Band installations, connect a power combiner/divider for each Main Hub band.1 Connect Cables2 Check Main Hub LEDsAfter connecting the LGCells, check all Main Hub LEDs to ensure that the system is operating properly.Connecting More Than Two LGCellsRepeat this procedure to connect any number of LGCell systems. For three systems, use a 3x1 power combiner/divider, and so on.Connecting LGCell to Base Stations, Microcells, or PicocellsOne or more LGCell systems can connect with any base station, microcell, or picocell. Before connecting an LGCell system to one of these, confirm the following items:•Connector type (LGCell uses N-type connectors)•Power distribution (LGCell supports either duplex or simplex)•Maximum power output (dBm) (Do not exceed the maximum input power into the Main Hub. If the input power is too high, an attenuator might be required.)For more information about connections to microcellular base stations or picocells, including connections to multiple base stations, see the Integration Module Installation and Reference Manual.From LGCells to Hybrid Power Combiner/Divider To Roof-Mounted Antenna, Repeater, or MBSConnect the DUPLEX, FORWARD, or REVERSE connector of one of the Main Hubs to an input/output port on the power combiner/divider using an N-male to N-male coaxial cable jumper.Connect the combined port of the power combiner/divider to a roof-mounted antenna, repeater, or MBS using an N-male to N-male coaxial cable jumper.Connect the DUPLEX, FORWARD, or REVERSE connector of the second Main Hub to the second input/output port on the power combiner/divider using an N-male to N-male coaxial cable jumper.
6 Common Problems, Troubleshooting, and Frequently Asked QuestionsThis section provides procedures for troubleshooting LGCell problems based on the front panel diagnostic LEDs. LGCell has no user-serviceable parts. Faulty or failed units are fully replaceable through LGC Wireless. U.S. customers, please contact us at 1-800-530-9960. International customers, please contact us at +1-408-487-2400.ContentsCommon Problems, Troubleshooting, and Frequently Asked QuestionsCommon Problems and Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3LED Indicator Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Troubleshooting Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Diagnostic Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6-2 Common Problems, Troubleshooting, and Frequently Asked Questions
6-3Common Problems and TroubleshootingThe LGCell has three sources of potential problems:•Malfunction of one or more LGCell component•Faulty cabling/connector•Antenna, base station, or repeater problemBy far, most problems discovered have to do with faulty cabling. All CAT 5 cable should be tested to TIA/EIA 568-A specifications.The diagnostic procedures are based on information in the Diagnostic Table on page 9. The table lists all LEDs and indicates what to do under certain circumstances. There is a blank table at the end of this section that you can copy and use to record the LEDs while you troubleshoot an LGCell system.After following the recommended procedures, if you cannot determine the cause of a problem, call LGC Wireless customer help hotline: 1-800-530-9960(International customers, please call +1-408-487-2400 for assistance.)
6-4 Common Problems, Troubleshooting, and Frequently Asked QuestionsLED Indicator DescriptionThe LGCell Main Hub, Expansion Hubs, and RAUs have front panel LEDs. The LEDs provide diagnostic information and operational status of each unit. Together they provide an efficient diagnostic display system, which help technicians find the fault if there is a malfunction.Main Hub LEDsThere are two sets of LEDs on the Main Hub front panel:•Main Hub MMF Ports •Main Hub Functionality LEDs•Main Hub MMF Ports LEDsProvides status on each of the Main Hub’s four MMF ports.•Main Hub Functionality LEDsThe LEDs provide diagnostic information on the Main Hub’s functionality.LED Color IndicationLINK STATUS GreenRedIndicates a good connection to Expansion Hub for that port.Connection problem to Expansion Hub.SYNC GreenRedIndicates Expansion Hub and any RAUs connected to it are operating properly.Problem with Expansion Hub or one of the RAUs.LED Color IndicationSYNC Green Indicates Main Hub is correctly producing the synchronization signal.POWER Green Turns green when Main Hub has power.
6-5Expansion Hub LEDsThere are two sets of LEDs on the front panel •   Expansion Hub    UTP/STP Ports•   Expansion Hub Functionality•   UTP/STP Ports LEDsProvides status on each of the Expansion Hub’s four UTP/STP ports.•Expansion Hub Functionality LEDsProvides diagnostic information on the Expansion Hub’s functionality.LED Color IndicationLINK STATUS GreenRedIndicates good connection to the RAU.Connection problem between Expansion Hub and the RAU plugged into that port.SYNC GreenRedIndicates RAU connected to it is operating properly.Problem with the RAU plugged into that port.LED Color IndicationSYNC Green Indicates Expansion Hub is receiving the synchronization signal from Main Hub.POWER Green Turns green when Expansion Hub has power.
6-6 Common Problems, Troubleshooting, and Frequently Asked QuestionsRAU LEDsRAUs have two LEDs:•Sync•PowerTroubleshooting GuidelinesThe LGCell Main Hub, Expansion Hub, and RAUs have front-panel indicator LEDs that provide diagnostic information and the operational status of each unit. Together they provide an efficient diagnostic display system for maintenance and fault location if a malfunction ever exists. The troubleshooting procedures in this section are based on the front panel diagnostic LEDs.The following table contains supplementary troubleshooting information that the diagnostic LEDs do not cover. Please check the table for a possible cause of a problem. Some simple checks or a minor adjustment might eliminate the problem and restore proper operation.LED Color IndicationSYNC Red Antenna lost sync and has shut down RF power.POWER Green Antenna is plugged in and the connected Expansion Hub is on.
6-7Problem/Symptoms CheckNo downlink signal output when all diagnostic LEDs are green. Make sure that there is a reasonable amount of power at the input of the Main Hub. Measure the output power of the coaxial cable using a power meter.The LGCell is intended for a different frequency band. Verify that your system corresponds to the desired frequency spectrum (for example, 800 MHz, 1800 MHz, or 1900 MHz). Check the part number of each unit.The LGCell is factory set for different bands of operation. Please be sure you have the proper band.The system gain is lower than specification. The optical fiber connector is dirty. Clean the fiber ST-connector, using the manufacturer’s recommended cleaning procedure.There are two types of Multi-Mode Fiber (MMF), 62.5/125 µm and 50/125 µm. Make sure the vertical run MMF is the 62.5/125 µm type of fiber.Remote Antenna Unit (RAU) power LED (green LED) stays off after you plug in the twisted pair cable.The Expansion Hub provides power to the RAU. Make sure the Expansion Hub is on.Make sure that the twisted-pair (TP) cable wiring conforms to the TIA/EIA 568-A standard. (For information about the standard, refer to Appendix B – TIA/EIA 568-A Cabling Standard.) Use a standard local area network (LAN) cable tester to perform this test. Possible errors are wrong wiring and/or cable length.The LGCell performance is intermittent when you use it for the CDMA application.The uplink and downlink gain is not balanced. A CDMA system performs active power control between the base station and the mobile unit. It is important to maintain a balanced link from the base station ports to the RAU ports (equal uplink and downlink gain) to optimize the performance of the LGCell.
6-8 Common Problems, Troubleshooting, and Frequently Asked QuestionsDiagnostic ProceduresUse the following table when diagnosing system problems. While troubleshooting, you can copy the blank table on page 12 and use it to record the LED colors on the Main Hub, the particular Expansion Hub indicating a fault, and the RAUs connected to it. This is necessary because the Main Hub, Expansion Hubs and RAUs might be geographically distributed.To determine where the fault might be1Go to the Main Hub and record the LEDs. The Main Hub indicates which Expansion Hub may be faulty by lighting one of its port LEDs red.2Go to the Expansion Hub attached to the port that has a red LED.3Record that Expansion Hub’s LEDs. The Expansion Hub indicates which RAU(s) may be faulty by lighting its antenna LED red.4Go to the RAU(s) connected to the Expansion Hub port indicating a fault. Record the error.5Compare your filled in table to the Diagnostic Table below and begin troubleshooting according to the notes indicated for your situation.
6-9Diagnostic TableMajor and Error Latch contacts indicate an alarm when the contacts go from a short to open state.*  Major Alarm contact will momentarily open for 100 milliseconds.The following numbers correspond to the “See Note” column of the Diagnostic Table above.1System is functioning properly.2The Expansion Hub is off. Make sure the power cord is connected to a live AC power jack and that the Expansion Hub power switch is in the 1 position.3Power is being delivered to the RAU but it is not turning on.•Check that the UTP/STP cable has been properly crimped and passes a standard CAT 5 compliance test.•If that is not the problem, replace RAU.Visual Alarm LEDs Remote Alarm Contacts See NoteRAU Expansion Hub Main Hub DB-9 ConnectorPORT LEDS HUB LEDS PORT LEDS HUB LEDSPOWER SYNC LINK STATUSSYNC SYNC POWER LINK STATUSSYNC SYNC POWER MAJOR ALARM CONTACTERROR LATCH CONTACTGreen Green Green Green Green Green Green Green Green Green Short Short 1Off Off Off Off Off Off Red Red Green Green Open Open 2Off Off Green Red Green Green Green Red Green Green Open* Open 3Off Off Red Red Green Green Green Red Green Green Open* Open 4Green Red Green Red Green Green Green Red Green Green Open Open 5Green Red Green Red Off Green Green Red Green Green Open Open 6Green Red Green Red Red Green Red Red Green Green Open Open 7Green Red Green Red Off Green Off Off Off Off Open Open 8Green Red Green Red Red Green Green Red Red Green Open Open 9Green Off Green Green Green Green Red Red Green Green Open Open 10Off Off Red Red Green Green Green Red Green Green Open* Open 11
6-10 Common Problems, Troubleshooting, and Frequently Asked Questions4Power is not being delivered to the RAU.•Switch the UTP cable to a different Expansion Hub port to see if the same problem occurs.If the LEDs on the new port are both green, there is a problem with the Expansion Hub.If the problem persists, there is a problem with either the RAU or the UTP/STP cable. •Check that the UTP/STP cable has been properly crimped and passes a standard TIA/EIA 568-A CAT 5 compliance test.If the cable passes the CAT 5 test, replace the RAU.5RAU has lost synchronization.•Make sure that the UTP/STP passes CAT 5 testing.•If the cable is OK, replace the RAU.6The Expansion Hub is not properly receiving the synchronization signal from the Main Hub.•The MMF cable connection might not be good or if system was working, the MMF downlink cable is pulled out or cut. Switch MMF cables.•If the problem persists, switch to a different Main Hub port. If this solves the problem, the Main Hub port is malfunctioning.•If the problem persists, there is an Expansion Hub problem. •If switching MMF cables is not practical, switch the uplink and downlink pairs. (A connection error may have been made when connecting the Main Hub UP port to the Expansion Hub UP port, and similarly for the DOWN ports.) •If the Expansion Hub SYNC LED turns green, one of the MMF cables was bad or the connection between the Main Hub and Expansion Hub was done incorrectly. If both are bad, this test will not help. Switch to a different Main Hub port. 7The Expansion Hub is not properly receiving the synchronization signal from the Main Hub.Too much loss on downlink MMF. Might be due to MMF pairs not attached to the proper connector.•Check that the “down” cable end is in the DOWN port connector on both the Main Hub and on the Expansion Hub. Same for the “up” cable end and connectors for the UP port.•If the problem persists, check the integrity of MMF cable using an Optical Time Domain Reflectometer. If the fiber is faulty, replace it.•If the MMF cable is OK, try using a different Main Hub port.
6-11•If the problem persists, replace the Main Hub. •If the problem persists, replace the Expansion Hub.8The Main Hub is off.Make sure the power cord is connected to a live AC power jack and that the      Main Hub power switch is in the 1 position.9Main Hub is not properly generating the synchronization signal.Turn off the Main Hub and turn it back on. If the sync LED stays off, the Main Hub might require replacement.10 The Expansion Hub is not properly sending the synchronization signal to the Main Hub.The MMF cable connection might not be good, or if the system was working, the MMF uplink cable is pulled out or cut.11 The RAU is off.•Check that the UTP/STP cable is operating properly.•If the system was working, the RJ 45 cable is pulled out or cut.
6-12 Common Problems, Troubleshooting, and Frequently Asked QuestionsDiagnostic TableUse the following blank table to record LEDs as you troubleshootVisual Alarm LEDs Remote Alarm Contacts See NoteRAU Expansion Hub Main Hub DB-9 ConnectorPORT LEDS HUB LEDS PORT LEDS HUB LEDSPOWER SYNC LINK STATUSSYNC SYNC POWER LINK STATUSSYNC SYNC POWER MAJOR ALARM CONTACTSERROR LATCH CONTACT
6-13Frequently Asked QuestionsThe following list provides answers to some frequently asked questions about LGCell:1What is the LGCell Distributed Antenna System?The LGCell Distributed Antenna System (DAS) contains multiple low-power radiating elements that are deployed around indoor facilities to improve coverage and capacity. The unique, patented architecture of the LGCell DAS provides an inexpensive solution to the cellular and PCS provider for coverage/capacity upgrades and private microcell applications.2What is twisted pair cable? Will it pick up spurious emissions?Twisted pair (TP) cable is the standard cable that you find at the back of your computer for the network hookup. TP cable is the most ubiquitious cable in any office building. Furthermore, TP cable is inexpensive and easy to install. The twisting nature of the cable creates a transmission line for efficient signal transfer and rejection of spurious emissions The LGCell uses a state-of-the-art common-mode rejection device that reduces pickup of spurious emissions on a TP cable by a factor of 10,000.3Can a single LGCell simultaneously support multiple access standards (such as 800 AMPS/TDMA?Yes. The LGCell is a frequency selective product. The LGCell system is transparent to the protocol that the base station and mobile unit use. You can view the entire system with all the cables together as a frequency selective repeater with a specified gain.4What is the bandwidth of the LGCell?LGCell selects from the RF bandwith, which can help prevent amplification of an unwanted signal, such as a competitor’s signal. Refer to the data specifications for the RF bandwith of the system. Another interpretation of bandwidth is the amount of data that the LGCell system can transmit. The microcellular or macrocellular base station to which the LGCell is connected limits the bandwith or capacity of the LGCell, which is a transparent system. Total, composite output power and spurious emissions are the only constraints that limit the amount of channels that an RAU can radiate. Furthermore, the LGCell system shall not limit the data rate of the modulation transmitted through the system.5Can the LGCell support multiband operation?The LGCell provides a wide variety of single-band products, including the U.S. 800 MHz, European GSM 900, DCS 1800, Korean PCS 1800, U.S. PCS 1900 systems, and iDEN. You can use these systems together to provide multiband services. In addition, LGCell has a Dual Band 900/1800 system available.
6-14 Common Problems, Troubleshooting, and Frequently Asked Questions6Can the LGCell system share the same UTP Category 5 Cable with the Ethernet network?No. The LGCell system can use the existing unused cabling inside the building; however, you cannot use the same cable to connect an RAU and a computer.7What is the minimum power input to the Main Hub?The coverage area of an RAU is directly related to the input down link power at the Main Hub. Therefore, an input power that generates an output power of 0dBm per channel optimizes the coverage area of an RAU.8What is the minimum detectable power of an RAU?The minimum detectable power of system with 1 RAU is -114 dBm in a 30 kHz bandwidth, -106 dBm in a 200 kHz bandwidth, and -98 dBm in a 1.25 MHz bandwidth, without taking into account the processing gain of different access standards.9What is the difference between connecting the LGCell to a roof-mounted antenna and to a microcellular base station?Connecting the LGCell to a roof-mounted antenna increases the coverage of the indoor environment. Connecting the LGCell to a microcellular base station improves both the coverage and the capacity in the building and might also provide a private wireless office application for the customer.10 Does each Main Hub require a separate coaxial feed to the base station?A typical RF input power per channel to the Main Hub is 0 dBm. This provides a lot of margin (link budget margin) for interfacing with antennas through a base station that typically has an output power of 20 dBm. Therefore, a power combiner/splitter might be installed between the MH and the base station. This enables one base station to connect to multiple Main Hubs. For details, refer to Section 2, LGCell Equipment.
Appendix A – Cables, Connectors, and AccessoriesThis section provides information about cables, connectors, and accessories that an LGCell application might require. LGC Wireless can provide these components, or the customer can. If the customer provides them, they must be on-site when LGC Wireless personnel arrive.Information in this section includes the following topics:•A description of the cables and connectors needed for the installation•Relative system gain over varying cable lengths ContentsAppendix A – Cables, Connectors, and AccessoriesCables and Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3LGCell Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
A-2 Appendix A – Cables, Connectors, and Accessories
A-3Cables and ConnectorsThe following cables and connectors are required for connecting LGCell. They are not provided with the LGCell equipment and must be on site or installed at the site prior to the LGCell installation. LGC wireless can provide and install these cables and connectors. Determine which cables (and their length) and connectors you need, then order them through a cable vendor or installer.Coaxial Cable – RF TransmissionStandard Coaxial Cable for Duplex RF Connections•Connects the Main Hub to a roof-mounted antenna, repeater, or duplex MBS.•Provides bi-directional downlink and uplink transmission with one cable for duplex RF connections.Standard Coaxial Cable for Simplex RF Connections•Connects a Main Hub to a simplex MBS, a simplex roof-mounted antenna, or repeater.•Provides unidirectional downlink and uplink signals on separate cables for simplex RF connections.MMF Cable with ST-Connectors –RF Transmission (Vertical Run)Standard Multi-Mode Fiber Optic Cable •    Connects Main Hub to Expansion Hubs•    Transmits (downlink) and receives (uplink) cellular and/or PCS signals.•    Accommodates distances up to 1 km.a028MMFCable
A-4 Appendix A – Cables, Connectors, and AccessoriesUTP/STP Cable with RJ-45 connectors –RF Transmission (Horizontal Run)Standard Category 5 Unshielded or Shielded Twisted Pair •   Connects the Expansion Hub to the RAUs.•   Transmits (downlink) and receives (uplink) cellular and PCS signals.•   Delivers electrical power to RAUs.•   Accommodates distances up to 60 meters.LGC Wireless recommends plenum-rated CAT 5 UTP/STP cable and connectors.a029UTP/STPCableRJ-45Connector
A-5Unshielded Twisted Pair Cable TerminationAll UTP (Unshielded Twisted Pair) shall be terminated according to the TIA/EIA 568-A standard. The following diagram describes how the four pairs should be terminated.The UTP/STP cable can be any length from 10 meters up to 60 meters. (Per TIA/EIA specifications, UTP/STP cable must be at least 10 meters.) For cables longer than 60 meters, system specifications are slightly degraded. When using high quality UTP/STP cable, lengths up to 60 meters can be used without degrading system performance.12 3 45 6 78BrownBrown/WhiteBlue Blue/WhiteGreen/WhiteGreen OrangeOrange/WhiteTop View of the Wiring Map for Category 5 (CAT 5) UTP Cable  (TIA/EIA 568-A Standard)Straight Connect
A-6 Appendix A – Cables, Connectors, and AccessoriesThe next two tables show how system gain on the uplink and downlink vary as a function of cable length (horizontal run, measured with 1 km of Multi-Mode Fiber).LGCell System Gain vs. UTP/STP Cable Length (800 MHz, iDEN, 900 MHz)UTP Cable Length (feet) Relative System Uplink and Downlink Gain (dB)0 No change in gain10 No change in gain20 No change in gain30 No change in gain40 No change in gain50 No change in gain60 No change in gain70 No change in gain80 No change in gain90 No change in gain100 No change in gain110 No change in gain120 No change in gain130 No change in gain140 No change in gain150 No change in gain160 No change in gain170 No change in gain180 -0.6190 -1.3200 -2.0210 -2.7220 -3.4230 -4.1240 -4.8250 -5.5260 -6.2270 -6.9280 -7.6290 -8.3300 -9.0310 -9.7320 -10.4330 -11.1
A-7LGCell System Gain vs. UTP/STP Cable Lengthfor 1800 MHz or 1900 MHz(Horizontal run, measured with 1 km of Multi-Mode Fiber)LGCell AccessoriesLGCell provides a full range of accessories that might be required for LGCell applications. Please see your LGCell Price Book or contact your account manager for the accessory list.UTP Cable Length (feet) Relative System Uplink and Downlink Gain (dB)0 No change in gain10 No change in gain20 No change in gain30 No change in gain40 No change in gain50 No change in gain60 No change in gain70 No change in gain80 No change in gain90 No change in gain100 No change in gain110 No change in gain120 No change in gain130 No change in gain140 No change in gain150 No change in gain160 No change in gain170 No change in gain180 -0.6190 -1.3200 -2.0210 -2.7220 -3.4230 -4.1240 -4.8250 -5.5260 -6.2
A-8 Appendix A – Cables, Connectors, and Accessories
Appendix B – TIA/EIA 568-A Cabling StandardThis appendix is a summary of the TIA/EIA 568-A Commercial Building Telecommunications Cabling Standard.The TIA/EIA 568-A commercial building cabling standard addresses the need for a common criterion covering cabling in commercial buildings. The standard was drafted to ensure support for a wide variety of applications, devices, and vendor products.The TIA/EIA 568-A standard assures a flexible cabling scheme which permits the planning and installation of communications cable without prior knowledge of the user's needs. This is especially valuable for new building construction and renovation where it is less costly and less disruptive to install a universal cabling system prior to occupancy.The need for a building cabling standard was recognized in the early 1980s. It resulted from the changes brought on by new technologies. The purpose of the original drafting committee was to provide a non-proprietary cabling system for both new and existing facilities.In 1985, the Computer Communications Industry Association approached the Electronic Industry Association (EIA) in regard to the market's confusion over cabling systems. The EIA and later its offspring, the Telecommunications Industry Association (TIA), addressed this via technical working groups comprised of industry participants. The resulting standard 568 addressed performance and safety issues related to technology and utilized many recognized and proven standards.The TIA/EIA 568-A standard defines the categories of UTP cabling, the categories of connecting hardware, patch cables, and provides guidelines on cabling practices.The TIA/EIA 568-A standard describes six sub-systems within a facility telecommunications cabling system summarized below. (This is intended as a summary only and is meant to provide a better comprehension of the standard. The complete TIA/EIA 568-A standard is available for purchase. Call 1-800-854-7179.)
B-2 Appendix B – TIA/EIA 568-A Cabling StandardHorizontal WiringThe horizontal cable is the portion of the cabling system which extends from the work area outlet to the telecommunications closet. The horizontal cabling is a star topology, with a maximum cabling run of 90 meters (295 feet), independent of media type.Voice Data4-pair 100 ohm UTP cable 4-pair 100 ohm UTP/STP2-pair 150 ohm STA62.5/125 µm fiber optic cableThe horizontal cable amounts to the greatest quantity of individual cables in the building. Although the TIA/EIA 568-A standard helps limit cabling options, consideration should be given to media type in order to support possible future needs. The cable selected should accommodate more than one network planning period.Backbone WiringThe backbone cabling provides the interconnection between the tele-communications closets and the equipment rooms and entrance facilities. The backbone cabling is also a star topology with the maximum cable length being media and applications dependent.The backbone cable is typically second to horizontal cables in terms of amount of cable deployed. The cable selected should accommodate a minimum of one to several network planning periods.
B-3HC Horizontal Cross-Connect MC Main Cross-Connect IC Intermediate Cross-ConnectWork AreaThe work area interconnects the horizontal cabling at the wall outlet to the desktop devices. The maximum allowable distance for patch cables is three meters (9.8 feet), based on the cable being of the same type as the horizontal cable.Telecommunications ClosetThe telecommunications closet is the area in a building dedicated to telecommunication equipment. The functions which take place in the closet include the interconnection point between horizontal and backbone cabling systems, the interconnection of two or more backbone cabling systems, and/or the interconnection of the entrance facility to the overall telecommunications cabling system.Note 1When the HC to IC distance is less than maximum, the IC to MC distance for optical fiber can be increased accordingly but the total distance from the HC to the MC shall not exceed the maximum of 2000m (6560 ft.).Note 2When the HC to IC distance is less than maximum, the IC to MC distance for UTP cable can be increased accordingly but the total distance from the HC to the MC shall not exceed the maximum of 800 m (2624 ft). For voice applications only.HC MCIC62.5/125 µm Optical Fiber Cable3000m (9843 ft.)500m(1640 ft.) 2500m(8202 ft.)HC MCIC2000m (6560 ft.)Maximum500m(1640 ft.)Maximum1500m(4920 ft.)Note 1TC MCIC800m (2624 ft) Maximum500m(1640 ft.)Maximum300m(984 ft.)Note 2HC IC/MC90m (295 ft)MaximumMulti-Mode Optical Fiber Cable62.5/125 micron Optical Fiber Cable100Ohm UTP Cable for Voice 100Ohm UTP Cable for DataHC IC/MC90m (295 ft)Maximum150Ohm STP-A Cable for Data
B-4 Appendix B – TIA/EIA 568-A Cabling StandardEquipment RoomThe equipment room is the area in a building where telecommunications equipment is located. Parts of or all of the telecommunications cabling system terminate here.Entrance FacilitiesThe entrance facility is where outside telecommunications service enters the building, and interconnects with the building's internal telecommunications systems. In a campus or multi-building environment, the entrance facility may also contain the building's backbone interconnects.Unshielded Twisted Pair Cable TerminationAll UTP (Unshielded Twisted Pair) shall be terminated according to the TIA/EIA 568-A standard.
 Appendix C – Compliance InformationAll LGCell systems comply with Optical Fiber Safety Standard IEC/EM60825-2. The LGCell distributed antenna system is rated as a Class 1 laser hazard system. It has an absolute maximum output power of -11.5 dBm at 1300 nanometers (nm). There are no restriction on the location or use of an LGCell system. No special precautions are required if standard work practices are followed. Additional information on the safe use of optical fiber communications systems is at the end of this appendix.The following provides LGC Wireless’ LGCell system approval status for various countries around the world. Some European countries require National Type Approval to their national standards (such as Germany).DAS9M-2-W:Telecom: A200296L (BAPT 222 ZV 15/ETS 300 609-4) and ETS 300 609-4, October 1998EMC: EN 300 339, June 1998, EN 61009-4-6, 1996, and EN55022/CISPR 22 Class BSafety: Power Supplies, Astec International Ltd., Model LPS 43, Universal Micro Electronics Co. Ltd., Model UPO651S-02, and International Power Sources, Inc., Model UPO651S-02 all have CB scheme certifications.Markings: The German Type Approval mark is required as well as the UK approval number. The CE mark is also required.DAS18M-2-W:Telecom: ETS 300 609-4, October 1998EMC: EN 300 339, June 1998Safety: Power Supplies, Astec International Ltd., Model LPS 43, Universal Micro Electronics Co. Ltd., Model UPO651S-02, and International Power Sources, Inc., Model UPO651S-02 all have CB scheme certifications.Markings: The UK approval number and the CE mark are required.
C-2 Appendix C – Compliance InformationDAS8M-2-W:Telecom: FCC: NOO-DAS800-1 (FCC Part 22.901d) Non-Broadcast TransmitterIndustry Canada: 3077281151A for the “Cellular 800” (RSS128, Issue 1)EMC: FCC: Class A, Part 15, Subpart BIndustry Canada: Same as FCCSafety: UL 1950, 3rd Edition and the cUL mark for the Canadian equivalent.NEBS: This is a customer driven conformance certification and typically desired of equipment that is intended to be installed in a Central Office environment. LGC products are intended as Customer Premise Equipment and it is not anticipated that they will be installed in a Central Office environment, therefore NEBS conformance certification has not been pursued at this time.Markings: The FCC approval number and the FCC logo are required. The word Canada followed by the Canadian approval number is required. The UL mark is required.DAS19M-2-W:Telecom: FCC: NOO-DAS800-1 (FCC Part 24E) Distributed Antenna System (Repeater)Canada: 3077331163A for the “PCS 1900” (RSS-133, Issue 1)EMC: FCC: Class A, Part 15, Subpart BIndustry Canada: Same as FCCSafety: UL 1950, 3rd Edition and the cUL mark for the Canadian equivalent.NEBS: This is a customer driven conformance certification and typically desired of equipment that is intended to be installed in a Central Office environment. LGC products are intended as Customer Premise Equipment and it is not anticipated that they will be installed in a Central Office environment, therefore NEBS conformance certification has not been pursued at this time.Markings: The FCC approval number and the FCC logo are required. The word Canada followed by the Canadian approval number is required. The UL mark is required.
C-3FCC Regulatory Notice:This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:•This device may not cause harmful interference.•This device must accept any interference received, including interference that may cause undesired operation.Industry Canada Regulatory Notice:This Class B (or Class A, if so indicated on the registration label) digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations.Cet appareil numerique de la Classe B (ou Classe A, si ainsi indique sur l’etiquette d’enregistration) respecte toutes les exigences du Reglement sur le Materiel Brouilleur du Canada.
C-4 Appendix C – Compliance Information
C-5
C-6 Appendix C – Compliance InformationIEC/EN 60825-2 - Safe Use of Optical Fiber Communication SystemsPart 2 of IEC 60825 provides requirements and specific guidance for the safe use of optical fiber communications where optical power may be accessible at some distance from the optical source. In this part of IEC 825, light emitting diodes (LED’s) are included whenever the word “laser” is used.Description of LGCell SystemThe LGCell is a distributed antenna system. It consists of three main components. A Main Hub, which is connected by dual mode fiber optic cables to one or more Expansion Hubs. Each Expansion Hub is connected by UTP CAT 5 cable to a Remote Antenna Unit. Because LED’s are used to send a signal over the fiber optic cable, the LGCell is covered under the IEC 60825 specification.Requirements under IEC 60825Under IEC 60825, LGC Wireless is required to determine the Class of operation of the LGCell system, the Hazard level of the LGCell system and any special instructions that must be included in an operators manual as well as any warning labels that may be required on the LGCell system. The LGCell is covered only under these definitions of section 3 of 60825. 3.2 enclosed system: A system in which, during normal operation, the optical radiation is totally enclosed, by light proof cabinets, components, total internal reflection or optical fiber cables and connectors. 3.3 end user: The person or organization using the optical fiber communication in the manner the system was designed to be used. The user cannot necessarily control the power generated and transmitted within the system. 3.4 hazard level 1: A hazard level 1 is allocated to any part within an optical fiber communication system at which, under reasonably foreseeable circumstances, human access to laser radiation in excess of the accessible emission limits (AEL) of class 1 for the applicable wavelengths and emission duration will not occur. 3.10 light emitting diode (LED): Any semiconductor device which can be made to produce electromagnetic optical radiation in the wavelength range from 180nm to 1mm. (The optical radiation is produced by the process of spontaneous emission, although some stimulated emission may be present.) 3.13 location with controlled access: A location where access to the protective housing (enclosure) is controlled and is accessible only to authorized persons who have received adequate training in laser safety and servicing of the system involved. Examples include optical cable ducts and switching centers.
C-73.14 location with restricted access: A location where access to the protective housing is restricted and not open to the public. Examples include industrial and commercial premises, PBX rooms, computer system rooms, and optical test sets. Distributed fiber networks may pass through unrestricted public areas, restricted areas within premises, as well as controlled areas or they may be deployed entirely within restricted business premises. 3.18 optical fiber communication system: An engineered assembly for the generation, transference, and reception of optical radiation arising from lasers in which the transference is by means of optical fiber for communication purposes. 3.19 reasonable foreseeable event: An event, the occurrence of which under given circumstances can be predicted fairly accurately, and the occurrence of which is a possibility. Examples of reasonably foreseeable events might include the following: fiber cable break, optical connector disconnection, operator error or inattention to safe working practices. Reckless use or use for completely inappropriate purposes is not to be considered as a reasonably foreseeable event.Installation NotesThe LGCell is covered under these parts of section 5 of 608255.2.1.3 Test Equipment: During installation or testing of an optical fiber cable or system, only test equipment of laser Class 1 should be used.5.2.1.5 Installation Rules: Each person engaged in the installation or service of an optical fiber cable communication system should observe all rules, procedures and practices established for the safe operation of optical fiber communication systems.Evaluation of LGC SystemThe LGCell is covered under Annex A of 60825The LGCell system is a self contained product that contains an optical fiber communication system that would be safe under normal operating conditions because the optical radiation is totally enclosed and contained under intended operation. However, because of the extended nature of the system, the optical power may be accessible a kilometer from the optical source. The LGCell system contains LED's, which are the source of radiation covered under IEC 825. Usually a whole fiber optical communication system would not be classified under IEC 825-2 in the same way required under IEC 825-1. This is because, under intended operation, the optical power is totally enclosed, and it could be argued that an interpretation of IEC 825-1 would give a class 1 to all systems, which may not accurately reflect the hazard potential of some systems. If the emitter can be operated separately, it should be classified according to IEC 825-1. However, the power output level of the LGCell system is so low that it always falls into the class 1 hazard level even under 100% modulation conditions. The absolute maximum allowed at 1300nm is +9.5 dBm. The absolute maximum accessible output of the
C-8 Appendix C – Compliance InformationLGCell fiber optic system is -11.5 dBm. Therefore there is no restriction as to location of use of the LGCell system and there is no labeling requirement.Suggested Work PracticesThe LGCell is covered under these parts of section D7 of 60825The following working practices are suggested for working on the LGCell system:•Viewing Fiber: Do not stare with unprotected eyes at the connector ends of the fibers or the ports of the hub.•Test Fibers Cables: When using test fiber optical cables, the optical power source shall be the last to be connected and the first to be disconnected. •Fiber ends: Any unconnected fiber ends should be covered with an approved cap. Do not use tape.•Broken Fiber Cables: Do not stare with unprotected eyes at any broken ends of the fibers. Report and have any broken fiber cables replaced.•Cleaning: Use only approved methods for cleaning optical fiber connectors.•Modification: Do not make any unauthorized modifications to this fiber optical system of associated equipment.•Live work: Live work is permitted on the LGCell as it is a class 1 hazard.•Signs: No warning signs are required.•Test Equipment: Use class 1 test equipment.
 Appendix D – ServicesThis appendix gives an overview of services that LGC Wireless provides.LGC Wireless offers a full range of professional services to ensure cost-effective and timely deployment of wireless networks. The seasoned staff of dedicated service professionals at LGC Wireless combine wireless system design and implementation expertise with a commitment to customer satisfaction unequalled in the industry. LGC offers a “Coverage Guarantee” and full access to its experts any time, 7 days a week and 24 hours a day.For both small and large installations, LGC can deliver specific services or a full, turnkey package that frees the customer from all the implementation details. LGC Wireless offers the following services:•Application Development•Preliminary System Design•Site Surveys•Installation and Commissioning•Project Management•Turnkey Implementation•Maintenance
Appendix E – Alarm Report Monitor (ARM2000)This appendix describes the Alarm Report Monitor (ARM2000) system, an option that you can order separately, for monitoring LGCell, PCS Extender, and Fiber Extender alarms.If your LGCell is connected to a microcellular base station, see the Integration Module Installation and Reference Manual for installation and operation of alarm devices and connectivity for that system.ContentsAppendix E – Alarm Report Monitor (ARM2000)Description of the ARM2000 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3ARM2000 System Basics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4ARM2000-RU (Remote Unit) Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4PCARM Installation for ARM2000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Security Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Alarm and Device Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16PCARM Operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
E-2 Appendix E – Alarm Report Monitor (ARM2000)
E-3Description of the ARM2000 SystemThe Alarm Report Monitor (ARM2000) software is used to display, manage, and record the alarm monitoring activity of one or more remote-ARM (ARM2000-RU) alarm monitoring and remote control units. The software provides a graphical display of up to 255 of these units and enables the user to identify and acknowledge alarm events, reset alarms, maintain event history, and page field service personnel. The system supports multiple users and tracks responsibility through log-in and log-out procedures, using four security levels to protect critical system functions.Alarm Report Monitor FeaturesThe ARM2000 system has the following features:•Graphic Color Status Display shows the entire system and individual device front panels with animation of all alarm reporting functions.•Remote System Reset Control uses point-and-click mouse control. Reset status is color keyed for on/off and pulsing conditions. •Alarm History and Control Logs keep track of all system events. You can view and print reports for the entire system, one specific device, or one channel of any unit.•Security Code Management allows restrictions to sensitive areas of the system. Four levels of security are available, with log-in and log-out procedures to track responsibility.•Journal Printer option keeps an active record of all alarm and control events. All activity is time and date stamped.Hardware and Operating System RequirementsTo run ARM2000, you need the following hardware and operating system:•IBM Pentium or compatible PC •Windows 95 or Windows 98 with MS-DOS prompts •VGA card with a minimum of 1024 Kbytes video RAM•8 Mbytes of conventional memory•Hard disk storage space: at least 10 Mbytes. Additional storage space allows larger history logs.•One Com port•US Robotics External 56Kbps modem (connects to COM1 port)•Mouse•Parallel printer (optional)
E-4 Appendix E – Alarm Report Monitor (ARM2000)ARM2000 System BasicsThe ARM2000 system is an alarm monitoring, reporting, and remote control system. Up to 8,160 individual alarm points can be monitored, displayed and logged by the system. The system consists of up to 255 remote-ARM monitoring units that can monitor up to 2,040 LGC systems (LGCell, PCS Extender, Fiber Extender) and a Pentium PC running the ARM software.These remote-ARM units communicate with the ARM software through dial-up modem connections. Each remote-ARM unit can use an external or internal modem. A database of these devices is set up in the PC, each device having a unique address. This address is set on the device and programmed into the PC using the Device Setup utilities of the software. The next figure illustrates both the direct connection of a single ARM unit and multiple units connected via a dial network.Multiple Remote-ARM Over Dial-up NetworkARM2000-RU (Remote Unit) InstallationThe ARM2000-RU is rack mounted in the same rack as the LGCell Main Hub(s).This remote-ARM unit has an “octopus” cable that enables it to monitor up to 8 LGCell Main Hubs. The ARM unit needs to be within 4 feet of each Main Hub that it will monitor due to the cable length.The ARM unit has an external power supply that requires a 110 VAC receptacle. Connect the power to the ARM unit after all cable and telephone connections are completed.Remote ARM with Internal ModemRemote ARM with Internal ModemDial-upNetwork
E-5Modem ConnectionsCommunications to or from the remote ARM can be configured in either of two ways:•Internal modem (inside remote-ARM unit)The internal modem must be a North American qualified modem for use in telephone networks that use North American standard call progress tones. This modem is inside the remote-ARM unit and requires an analog phone line connection with an RJ-11 male connector. Connect the phone line to the port marked “Line” in COM1, at the back of the remote ARM. •External modem (via RS-232 COM1)LGC Wireless recommends a US Robotics External modem qualified in the country of use. To install this modem, you need a DB-25 to RJ-45 converter cable and a cable with RJ-45 male connectors on both ends.If you are in a country that does not use North American standard call progress tones, you need to use an external modem with the ARM2000-RU unit.If you use the US Robotics External modem, you need to prepare the modem with initialization commands before you use it, as “Preparing the PC Modem” on page 7 describes. Take the following steps to install the modem:1Connect the phone line to the phone line marking at the rear of the modem.2If you choose to be notified by a phone ring of an incoming call, then connect the phone to the phone marking at the rear of the modem via RJ-11 male connectors on both ends.3Connect the DB-25 to RJ-45 converter at the rear of the modem.4Run the other end of the RJ-45 cable to the RS-232 COM1 port at the rear of the remote ARM.Alarm Cable ConnectionsTo connect the LGCell Main Hub(s) to the remote ARM, use the two-to-eight-port connector cable. Make the following connections to monitor the following alarms:Connector Alarm MonitoredJ1 Alarms 1,2    - Main Hub 1J2 Alarms 3,4    - Main Hub 2J3 Alarms 5,6    - Main Hub 3J4 Alarms 7,8    - Main Hub 4J5 Alarms 9,10  – Main Hub 5
E-6 Appendix E – Alarm Report Monitor (ARM2000)J6 Alarms 11,12 – Main Hub 6J7 Alarms 13,14 – Main Hub 7J8 Alarms 15,16 – Main Hub 8Input Alarm input to ARM unitOutput Remote Reset from ARM unitAlarm Cable and ConnectorsTest SetupAfter the ARM unit is powered up, the unit should be reset and ready for communicating to the PCARM system for final programing. When the ARM is powered, wait 15 seconds and then press the TEST button on the left front of the unit. All 16 circuit alarm LEDs on the front panel should light and toggle to green momentarily. If this does not occur, power down the ARM unit for 15 seconds and start over.The LED final state should be green to indicate a proper connection and a no-fault condition for each Main Hub that is also powered up. Each Main Hub has 2 LEDs assigned to it. Alarm circuits that do not have an “octopus” cable connected will be red.
E-7PCARM Programming InformationIf multiple ARM200-RU units are installed that will be controlled by one PCARM system, then each ARM200-RU unit must be configured with a unique device ID (1-255) for programming by the PCARM system. Each ARM unit must have a different device ID if it will be controlled by one PCARM system. There is a label on each ARM unit that indicates what device ID it has be configured for. The device number and which Main Hub(s) it has been connected to, is important information that must be provided to the person programming the PCARM.PCARM Installation for ARM2000The PCARM software runs the ARM2000 system. This section describes how to install the PCARM software and configure it for running the ARM2000, with a subsection on each of the following steps:1PC modem preparation2Remote programming of a remote-ARM unit3PCARM software installation4Modem connections5Testing of communications between PCARM and a remote-ARM unitPreparing the PC ModemTo communicate with the internal modem of the remote-ARM unit (ARM2000-RU), prepare the US Robotics 56K external modem for the Intel Pentium PC that will be running the PCARM software via the following steps:1Install the US Robotics 56K external modem in the COM1 port of the Intel Pentium PC. (Follow the installation instructions that accompany the modem.)2Enter the AT commands to initialize the 56K modem to communicate with the internal modem of the remote ARM. To enter the AT commands1Choose Accessories from Programs on the Start menu.2Click HyperTerminal.3Double click HyperTerminal.exe.4Enter a name of connection (“Test”, for example).5When prompted to enter a phone number, select direct to COM1 from the “CONNECT USING” pull-down menu and click OK. Then click OK on COM 1 properties.
E-8 Appendix E – Alarm Report Monitor (ARM2000)Once connected to COM1, enter AT and press Enter. (You will see OK displayed at this point and will not see any characters.) Then enter the following AT commands.•“AT&F”•“AT&A0” •“AT&B1” •“AT&K0” •“AT&M0” •“AT&N3” •“AT&W” After you enter these commands, your PCARM modem is ready for communication with the internal modem of the remote ARM. Exit HyperTerminal. (You do not need to save this session). Remote Programming of a Remote-ARM UnitTo program the remote-ARM unit with the phone number to dial out to the PCARM modem when an alarm condition occurs, make sure that the remote-ARM unit is connected to an analog dial-up line and is powered up. Call from the PCARM, taking the following steps. (Make sure the US Robotics 56K modem is installed in the PCARM before programming.)1Click Start.2Click Programs.3Click Accessories.4Click HyperTerminal.5Double click HyperTerminal.exe.6Type connection name (“TEST”, for example) and click Enter.7Type the phone number of the line to which the remote-ARM unit is connected.8Click OK.9Click Connect.When a connection is established to the remote-ARM unit, the HyperTerminal status bar will indicate the connection time.10 After a connection is established, type “P” and then press the Enter key.A prompt appears on the screen asking you to enter the phone number:      (ENTER PHONE NUMBER)
E-911 Enter the dial-up number (the PCARM modem number) that the remote ARM will dial to establish communications with the PCARM. If you need to enter a digit to access an outside line (such as 9), separate this digit from the phone number with a comma for a pause. Enter 1 for long distance if required. 12 End the session by entering “ATH0”.13 Exit HyperTerminal. You do not have to save the session.PCARM Software InstallationTo install the PCARM files 1Place the PCARM disk in the A (or appropriate) drive.2Open Windows Explorer from the Program menu under the START Button.3Make directory PCARM under the C drive.4Make two sub-directories in the PCARM folder, labeled ARCHIVE and BACKUP.5Exit Windows Explorer.6From the START Button RUN A:\PCARM.exe. Press OK.The WinZip program will extract and unzip the PCARM files.7Save the unzipped PCARM files to the C:\PCARM directory.8Close the WinZip window.9Take out the PCARM disk and store in a safe place.10 After you install these files, verify that the files are in the PCARM directory via Windows Explorer, then exit Explorer.To create a shortcut for PCARM1Right click the mouse on the Windows 95 desktop.2Place the mouse pointer over NEW. Another menu pops up.3Click Shortcut.4Click Browse.5Double click PCARM.exe.6Click Next.7Click Next (again).8Double click the desired icon.A “PCARM.exe” icon appears on the desktop.
E-10 Appendix E – Alarm Report Monitor (ARM2000)To set up PCARM software1Double click the PCARM.exe shortcut icon that you created.The System View screen appears.2Click setup.3Click Configure ARM Manager (change the configurations to desired settings). Make sure “use modem” is YES. Once changes have been made, save the changes and exit.4Click Setup (again).5Click Device.6Click Remote Arm.7Enter the device address (0001, for example).8Enter the location (LGC Wireless, for example).9Enter the phone number for the remote-ARM unit (assigned to that hardware device number).10 Enter appropriate alarm names, short names, alarm & clear states, and pager. Select no for pager for all alarms entered. (See Inputs sample screen.) If you are in Device 0001, alarm names are already set. This is the default database. 11 Save the data you entered. (You will not see any indicator of saved data.)12 Click Program Outputs.13 Enter the appropriate number of devices, and Energize and De-Energize states.  (See Outputs sample screen). If you are in Device 0001, there is default data present.14 Save data once entered. 15 Once data has been saved, exit out of setup. (This will take you to the Device View screen.)To receive alarms from the remote-ARM unit or units, leave the PCARM running continuously on the PC. The System View screen indicates the status of each device (REMOTE ARM UNIT).
E-11Modem ConnectionsCommunications to or from the remote-ARM unit can be configured in either of two ways:•The internal modem  (inside the remote-ARM unit) uses North American call progress tones.•External Modem (via RS-232 COM1) used for International locations when North American call progress tones are not used.Internal Modem:  (Required parts:  cable with RJ-11 male connectors on both ends)The internal modem is situated inside the remote-ARM unit. The phone line connection is connected to the port marked, “Line” in COM1, at the back of remote-ARM unit. External Modem:  (Required parts:  US Robotics External modem, DB-25 to RJ-45 converter, cable with RJ-45 male connectors on both ends)If you choose to use an external modem, use a US Robotics 56K external modem.  If this modem is used, please prepare the modem with the initialization commands given in the modem preparation section prior to usage.  Connect the phone line to the phone line marking at the rear of the modem. Connect the DB-25 to RJ-45 converter at the rear of the modem, and run the other end of the RJ-45 cable to the RS-232 COM1 port at the rear of the remote-ARM unit. Verify that you are using a remote-ARM unit that does not have an internal modem (part number ARM2000-RU-EXT).Testing Communications Between PCARM and Remote-ARM UnitTo test communications between the two modems, the PCARM software needs to be running.  (Install the software and configure it, if not done.)1Turn on the PC and wait for Windows 95 to load.2Click the PCARM.exe shortcut icon to run the PCARM program.This puts you at the System View screen.3On the System View screen, click the device with which you want to communicate.This puts you at the Device View screen. To find the device, place the mouse pointer over the cell for the device.4On the Device View screen, click Test to test communications between the PCARM and the remote-ARM unit.An alarm condition prompts the remote-ARM unit to dial the PCARM (alternate method of test).
E-12 Appendix E – Alarm Report Monitor (ARM2000)Security SetupTo access the security utility, click Setup on the Device View or System View screen. Choose the desired security system by placing the cursor in the appropriate box and clicking. For a secure system you will need to enter a name, password (security code), and clearance level for each individual who will use the system. In a secure system at least one operator must have a Level 3 security clearance. If the system is set up to be Tracked, or Secured, an operator can log on and log off from the Setup menu on the Device View or System View screen.
E-13Security Setup Utility OverviewThe Security Setup Utility enables the user to setup the various security features of the ARM. It is made up of two different screens. One to select the system wide security options and the other to enter the system operators.Access to the Security Setup UtilityYou can access the Security Setup Utility from the System View or Device View screen or the Control Panel. From any of these, select Setup / Security.  If the system is in tracked or secured mode, you must have Level 3 security clearance. If  the operator who is currently logged on does not have Level 3 clearance, an error message is displayed. In a secured system, you need to enter a second security code to access this utility.
E-14 Appendix E – Alarm Report Monitor (ARM2000)Security Options ScreenSecurity Options FieldsTo select a Security Setup field, use the SPACEBAR key or position the cursor over the field you want and click the left mouse button. You can set up the security of the system in one of three ways:•Open systemIn an open system, all functions are available at all times. No log-on or log-off procedure is required. This is the least secure system.•Tracked systemIn a tracked system, each user is assigned a security level and an access code. There are four levels of security, each with progressively more access to the system. After a user logs on at a given level, all functions for that level are available to the user.  •Secure systemA secure system functions in the same way as a tracked system, except that level 3 functions (archive and system management) require reentry of the security code.
E-15Security Codes ScreenThe Security Codes screen enables the system supervisor (highest security, Level 3) to change or add operator names and security codes and assign individual security levels.Security Code Levels•Level 0Allows a user to view status and history screens and to print reports.  At this level, the user will not be able to acknowledge alarms.  Any attempt to perform a function will result in a prompt for a higher security code or log on.•Level 1All of Level 0 plus the ability to acknowledge alarms.•Level 2All of Level 1 plus the ability to control the remote-ARM relays.•Level 3Manager Level. Unrestricted access to all system functions. This level is required for all setup functions.
E-16 Appendix E – Alarm Report Monitor (ARM2000)Alarm and Device SetupDuring the initial test after you complete the setup, PCARM displays the appropriate clear and alarm conditions. To acknowledge these conditions, click the ACK button on the Device View screen. During initial setup, all 16 devices are assumed to be enabled.Disabling Alarms and DevicesTo disable an alarm, place the mouse pointer over the alarm and right click. PCARM displays a dialog box that asks if you want to be reminded to enable after an elapsed time. Make your selection of time and press Enter. The alarm is disabled at this point, both in PCARM and on the REMOTE UNIT display panel. You can also enable a device in this manner from the System View screen.Enabling Alarms and DevicesTo enable an alarm, place the mouse pointer over the desired alarm and right click. PCARM displays a dialog box that gives you options to enable or cancel. Click the enable options, or press E on the keyboard to enable them.  (If you attempt to enable an alarm when appropriate conditions have not been met, the alarm indicator (red LED) flashes and the PC buzzer sounds.)You can also enable a device in this manner from the System View screen.
E-17
E-18 Appendix E – Alarm Report Monitor (ARM2000)Resetting the Main Hub RemotelyThe remote-ARM unit is designed not only to monitor the alarm conditions, but also to reset the Main Hub from a remote site. When an alarm condition occurs, you can clear the alarm from the PCARM via the control menu and then reset the Main Hub.To reset an alarm condition remotely1From the Device View screen, click Control Menu to go to the Control Panel screen.2Choose a hub to reset by clicking that hub.PCARM displays the Control Relay dialog box, which gives you the option to pulse or change the state of the relay.3Click Pulse to reset the hub.PCARM displays the Pulse Duration dialog box, which asks you for a pulse time and displays the following message:    ONLY ONE (1) SECOND PULSE IS REQUIRED TO RESET THE HUB.
E-194Choose your time and press EnterIf the alarm condition has cleared, the PC buzzer sounds and a status box appears on your screen.5Click Go To.PCARM displays the Device View screen, on which the cleared alarm(s) flash green.6To acknowledge the clear condition, click ACK.The flashing green indicator or indicators become solid green.  Control Relay Dialog Box
E-20 Appendix E – Alarm Report Monitor (ARM2000)Pulse Duration Dialog BoxControl Panel Status Box
E-21PCARM OperationsTo display, manage, and record alarm monitoring activity in PCARM, you can perform operations from the System View, Device View, and Alarm View screens. You can also enable and disable alarms and devices from the System View and Device View screens.System View ScreenOverview of the System View ScreenThe System View screen displays the current status for all of devices in the entire system. On the screen, 255 windows display the status for each device in the system. When no alarms are present, the windows for all of the active devices are green. If an alarm occurs, the window of the particular device flashes red and the PC’s buzzer sounds. A status bar at the bottom of the screen displays the current status of the communications port and operator.  At the top of the screen is a menu bar for program navigation.
E-22 Appendix E – Alarm Report Monitor (ARM2000)Window Status IndicatorsDevice SelectionTo view a particular device, position the cursor over the window of the device and click the right button. This transfers the program into the device view mode. See “Device View Screen” on page 25.Disabling DevicesYou can disable devices to allow maintenance of the monitored equipment without receiving false alarms. To disable a device, position the cursor over the device and click the right mouse button. PCARM displays a dialog box that prompts you to enter a reminder time. Enter a desired amount for timer (in minutes) to be reminded that the device has been disabled, or 0 for no reminder.Enabling DevicesTo enable a device, position the mouse over the desired disabled device and click the right mouse button.  This will cause a confirmation dialog box to be displayed.  To enable the device, click the Enable button on the dialog box or press the ‘E’ on the keyboard.  To cancel, click the Cancel button, press the ‘ESC’ or ‘C’ key on the keyboard.  Window State ConditionGreen All circuits clear and acknowledged.Red Alarm condition on one or more channels. All alarms are acknowl-edged.Green Flashing Unacknowledged clear event on one or more channels.Red Flashing Unacknowledged alarm on one or more channels.Red/Green Flashing Both alarms and clears that are unacknowledged.Blue Flashing Unit is not responding to polls.Yellow  The device is output only.Gray Unit is not programmed.Black Device has been disabled.
E-23Status BarThe status bar is located on the bottom of the System View screen. It displays the current status of the system. It has three status windows. The function of each of these windows is described in the following sections:Communications Port StatusThis window is used to display the current status of the communications port.  If the system is configured to be directly connected to a device it will display “Direct Connect”.  If the system is configured to use a modem it displays the current status of the modem.Operator Status:This window is used to display the operator status. In an open system, it displays “Open System”. In tracked and secured systems, it displays the name of the operator that is currently logged on or “Please Log On” if no operator is logged on.System View MenusThe System View menus are located on top of the screen. Descriptions of the menu choices follow:•FileThis selection displays a pull down menu with the following choices:ArchiveThis selection displays a sub-menu that allows clearing the active Alarm and/or Control Log and saving the current contents to an Archive file. The data from the Alarm and/or Control Log are stored in the sub directory archive. These files are Dbase III compatible. In a tracked or secured system, the user must have a Level 3 security code.ExitThis selection terminates the ARM program and returns to DOS.•HistoryThis selection displays an Alarm History Screen that lists a full chronological history of all events (alarms\clears) for the entire system.
E-24 Appendix E – Alarm Report Monitor (ARM2000)•SetupThis selection displays a pull down menu with the following five choices:Config ARM:This selection accesses the ARM configuration utility.Device:This selection displays a sub-menu that allows access to the device setup utilities as described below.REMOTE-ARM:This selection accesses the remote-ARM setup utility.Security:This selection accesses the Security Setup utility. Log On:This selection displays the Log On Dialog Box.Log Off:This selection displays the Log Off Dialog Box.•Operator LogThis selection displays an Operator History Log that lists a full chronological history of all operators that have logged into and logged out of the system.•Print Current AlarmsThis selection generates a report showing all current alarm conditions in the system.
E-25Device View ScreenOverview of the Device View ScreenThe Device View screen displays a Graphic Color Status Display of any individual front panel with animation of all alarm reporting functions.  Each Device View has the location name of the device printed at the top of the screen (LGC Wireless in the example above).  When no alarms are present all channel LED’s are green, there is a message ‘ALL CLEAR’, and the time.  Each LED has an associated name (Short Name) printed above it.  There is a status bar at the bottom of the screen that displays the system status.  There is a menu bar at the top of the screen for program navigation.When an alarm occurs, its associated LED begins to flash red and the PC’s buzzer sounds until the alarm is acknowledged. Below the front panel, the alarm name, status, and time/date the alarm occurred is displayed.When the alarm clears, its associated  LED flashes green and the PC’s buzzer sounds three beeps.  When the clear is acknowledged, the channel LED is steady green.
E-26 Appendix E – Alarm Report Monitor (ARM2000)When you are at the Device View screen, if an event occurs on another device, a New Event dialog box will pop up over the Device View screen. The New Event dialog box offers the following choices:•Go ToSelect to display the device that is alarming.• System ViewSelect to display System View screen.•ContinueSelect to continue with the device that is presently displayed.Acknowledging AlarmsAlarms and Clears are both acknowledged in the same manner. Simply position the cursor over the ACK button and click the left mouse button. If the system has been configured as an open system and the Require Initials on Acknowledgment option has been enabled, the Enter Initials dialog box will be displayed. Simply enter your initials followed by the enter key and the alarm is acknowledged. In tracked and secured systems, an operator with a security level of one or greater must be logged on in order to acknowledge and alarm or clear. If no one has logged on prior to clicking the acknowledge button, the Log on dialog box will be displayed. The ESC key will cancel the log on procedure without acknowledging the alarm.Disabling ChannelsIndividual alarm channels can be disabled to allow equipment maintenance without causing false alarms. To disable an alarm channel, position the cursor over the desired disabled channel’s LED and click the right mouse button. A dialog box will then pop prompting to enter a reminder time. Enter the desired timer (in minutes) for the disabled reminder to pop up. Enter 0 if no reminder is required.Enabling ChannelsTo enable the channel, position the cursor over the desired channel’s LED and click the right mouse button. This will cause a confirmation dialog box to be displayed. To enable the channel, click the Enable button or press the E key. To cancel, click the Cancel button or press the ESC or C key.Alarm View Dialog BoxThe Alarm View dialog box has been provided as a quick way of viewing the last two events that occurred on a given channel.  To display the Alarm View dialog box, position the cursor over the desired channel’s LED and click the left mouse button.  This is a non modal dialog box, clicking another channel or anything else on the screen will close the dialog box and perform the selected function.  If the selected channel has no alarms an error box will be displayed.
E-27Communications Test FunctionA communications test function has been provided to test communications between ARM and the remote-ARM unit and update the status. This should be done after a new device is installed. To test a device, position the cursor over the test button and click the left mouse button and ARM will call the remote-ARM unit. When the test is complete a dialog box stating the result of the test will be displayed.Status BarThere is a status bar located at the bottom of the screen.  This status bar displays the current status of the system.  Alarm View Screen OverviewThe Alarm View Screen provides a quick view of all the alarms (acknowledged and unacknowledged) in the entire system. The alarms are displayed in chronological order from the newest to the oldest. The unacknowledged alarms are displayed in red, and the acknowledged alarms are displayed in blue. Clicking any of the alarms in this view causes the program to switch to the device view of the selected alarm. A scroll bar on the right hand side of the screen is provided to scroll through the alarm list. A menu bar, at the top of the screens, is provided to navigate to other screens. The contents of this screen can be printed to a printer or file.
E-28 Appendix E – Alarm Report Monitor (ARM2000)ReportsYou can display the following reports in PCARM:•Alarm History Log•Alarm History by Device•Alarm DetailAlarm History LogThe Chronological Alarm History screen displays the entire contents of the Alarm History Log in chronological order (newest to oldest). A scroll bar on the right hand side of the screen is provided to scroll through the alarm log. The scroll bar thumb shows the current position in the file. A menu bar located on the top of the screen is provided to navigate through the program.This screen shows the location of the alarm, channel name, and status. For a more detailed view of an individual alarm, position the cursor over the desired alarm and click the left mouse button. This causes the Alarm Detail dialog box to be displayed. In addition to the alarm information, this screen also displays any loss of communications and restoration of communications.Alarm History by DeviceThe Device History screen displays the chronological alarm history (newest to oldest) of one specific remote-ARM device. A scroll bar on the right hand side of the screen is provided to scroll through the alarms. The thumb of the scroll bar shows the position in the file. A menu bar located at the top of the screen is provided to navigate through the ARM.This screen shows the channel name, status, and time the event occurred. For a more detailed view of the event, position the cursor over the desired event and click the left mouse button and the Alarm Detail Dialog Box will be displayed. Alarm Detail Dialog BoxThe Alarm Detail dialog box is displayed when you click any event in the Alarm History logs. This dialog box displays the following information for the selected event:•Location name•Channel name•Status of the channel•Time the event occurred
E-29•Time the event was acknowledged•Initials of who acknowledged the eventOperator Log The Operator Log is a chronological history (newest to oldest) of the operators who have logged on to the system. This screen contains columns to display the operator name, time logged on, and the time logged off.You can access the Operator Log only from the System View screen. Select Operator Log from the main menu.Report PrintingPCARM provides the ability to print any of the Alarm, Control, and Operator logs to either a printer (connected to LPT1) or a file.  To print a log, select Print from the menu of the displayed log. This pops up the following dialog box.In this dialog box, click the square button next to either LPT1 or FILE. To start printing, click the OK button. If you select FILE, PCARM displays a second dialog box in which you can enter the name of the file (up to 13 characters).When printing begins (to file or printer), PCARM displays the Print Progress dialog box. You can abort the print job at any time by clicking the Cancel button.
E-30 Appendix E – Alarm Report Monitor (ARM2000)Alarm LogsTo print an alarm log, select the log you want and then select Print from the log screen’s menu. Control LogsTo print a control log, display the log and then select Print from the log screen’s menu.Current AlarmsARM provides the ability to print a list of all current alarms (acknowledged and unacknowledged) to a printer.  To print all current alarms, select Print Current Alarms from the menu on the System View screen.Operator LogTo print the Operator Log, select Print from the Operator Log menu.

Navigation menu