ADC Telecommunications DLC0802A Digivance 800 MHz 20 Watts System User Manual 75150
ADC Telecommunications Inc Digivance 800 MHz 20 Watts System 75150
Contents
manual6
FCC ID: F8I-DLC0802A User Manual - Part 6 ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation Right-click here to open Host Fwd Att pop-up screen Figure 4-8. HOST RF Display Figure 4-9. Host Fwd Att Pop-Up Screen 2.6 Determine Output Signal Level at STM Antenna Port The RF output signal level should be measured at the STM ANTENNA port to verify that maximum composite signal level is at the required level. Use the following procedure to determine the power level: 1. Verify that RF ON/OFF switch on the LPA in the OFF position. 2. Disconnect the antenna cable from the STM ANTENNA port. 3. Connect a spectrum analyzer or RF power meter to the STM ANTENNA port. (Check the input rating of the test equipment. Insert a 30 dB 100 W attenuator if necessary.) Page 4-12 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation 4. Place the RF ON/OFF switch on the LPA in the ON position. 5. If using a spectrum analyzer, proceed to step 6. If using a power meter, measure the composite signal power from the STM and then proceed to step 8. 6. Measure the RF level of a single carrier, such as the control channel, in dBm. Make sure the resolution bandwidth of the spectrum analyzer is 30 kHz. 7. Calculate the total composite signal power using the following formula: Ptot = Pc + 10Log N – (see Note) Where, Ptot is the total composite power in dBm Pc is the power per carrier in dBm as measured in step 6, and N is the total number of channels. Note: If calculating the composite power for a CDMA system, reduce the initial result by 16.23 dBm 8. Record the result measured in step 5 or calculated in step 7. 9. Place the MUTE/NORM/RESET switch on the LPA in the OFF position. 10. Disconnect the spectrum analyzer or RF power meter from the STM ANTENNA port. 11. Re-connect the antenna cable to the STM ANTENNA port. Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts EIRP and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. 2.7 Enter Remote Forward Attenuation The STM internal forward path attenuator setting is used to reduce the power level of the composite output signal level at the STM antenna port. The maximum composite output signal level at the STM antenna port is set using the Host internal forward attenuator (see Section 2.4). However, component variations may result in the output power at the STM antenna port being slightly above or below the required power per channel. If this is the case, the STM forward attenuator may be used in conjunction with the Host forward attenuator to add or remove attenuation to produce the required output signal level. If less power is required, the STM forward attenuator may be used to reduce the power level. The default setting is 0 dB. Use the following procedure to change the STM forward attenuation: 1. Click on the REMOTE LPA tab. The REMOTE LPA display will open within the DEMS main window as shown in Figure 4-10. Page 4-13 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation Right-click here to open the Remote Fwd Att pop-up screen RF output signal level Figure 4-10. REMOTE LPA Display 2. Check the level of the RF output signal (as determined in Section 2.6) against the system design plan specifications. Table 4-1 shows the output signal level required to provide 5 watts per channel for systems with 1 to 2 channels. The maximum output signal level permitted for the system is 40.5 dBm (11 Watts). 3. Determine if more or less attenuation is required to produce the required output signal level. 4. Right-click on the Remote Fwd Att section of the display (see Figure 4-10). The Remote Fwd Att pop-up screen will open as shown in Figure 4-11. 5. Enter the required attenuation value and click OK to close the pop-up screen and to make the changes take effect. Table 4-1. Composite Output Signal Levels NUMBER OF CHANNELS OUTPUT SIGNAL LEVEL REQUIRED TO PROVIDE 5 WATTS PER CHANNEL 37 dBm 40 dBm When there are three or more channels, each channel will always be less than 5 watts since the system has a maximum power output of 11 watts (40.5 dBm). Page 4-14 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation Figure 4-11. Remote Fwd Att Pop-Up Screen 6. Verify that the appropriate RF output signal level appears in the RF Pwr-VSWR Low section (see Figure 4-10). This is primarily a reference value and should not take the place of external test equipment when determining the power level of the composite RF output signal. Depending on the modulation type and number of channels, the DEMS software may report a power level that is higher or lower than the actual RF output signal. Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts EIRP and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons. 2.8 Enter Host Reverse Attenuation The level of the RF signal that should be input to the BTS will vary depending on the type of BTS, the receive distribution, and the number of channels present. To interface with the BTS, the reverse path signal level must be adjusted to provide the signal level required by the BTS. The HU provides from 0 dB of gain to +30 dB of gain in the reverse path. Use the following procedure to set the reverse path gain: 1. Check the BTS manufacturer’s specifications to determine the composite signal level required at the BTS reverse path input port. 2. Determine the overall gain and loss imposed on the signal by the antenna, antenna cable, and by the cables that connect the HU to the BTS. 3. Determine the amount of gain required to raise the reverse path signal to the level required at the BTS. 4. Click on the HOST RF tab. The HOST RF display will open within the DEMS main window as shown in Figure 4-12. Page 4-15 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation Right-click here to open the Host Rev Att pop-up screen Right-click here to open the Host Div Rev Att pop-up screen Figure 4-12. HOST RF Display 5. Right-click on the Host Rev Att section of the display (see Figure 4-12). The Host Rev Att pop-up screen will open as shown in Figure 4-13. Figure 4-13. Host Rev Att Pop-Up Screen 6. Enter the attenuation value that will provide the required gain. Refer to Table 4-2 for the attenuation values and the corresponding gain (nominal) values. 7. Click OK to close the pop-up screen and to make the changes take effect. 8. Click OK to close the pop-up screen and to make the changes take effect. Page 4-16 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation Table 4-2. Reverse Path Attenuation Settings and Nominal Gain Provided ATTENUATION SETTING GAIN PROVIDED 0 dB → 2.9 ATTENUATION SETTING 11 dB → 30 dB GAIN PROVIDED ATTENUATION SETTING GAIN PROVIDED 19 dB 22 dB → 8 dB 1 dB 29 dB 12 dB 18 dB 23 dB 7 dB 2 dB 28 dB 13 dB 17 dB 24 dB 6 dB 3 dB 27 dB 14 dB 16 dB 25 dB 5 dB 4 dB 26 dB 15 dB 15 dB 26 dB 4 dB 5 dB 25 dB 16 dB 14 dB 27 dB 3 dB 6 dB 24 dB 17 dB 13 dB 28 dB 2 dB 7 dB 23 dB 18 dB 12 dB 29 dB 1 dB 8 dB 22 dB 19 dB 11 dB 30 dB 0 dB 9 dB 21 dB 20 dB 10 dB -- -- 10 dB 20 dB 21 dB 9 dB -- -- Enter Host Forward and Reverse Delay The forward and reverse delay function allows entry of from 0 to 63 µsec of delay in the forward and reverse paths. This feature is used when multiple systems are used to transport the same channel and there is a significant difference in the path delay between systems. Additional delay may be entered to balance the overall system delay. The amount of delay required must be calculated by the RF engineer and should be included in the system design plan. The default setting is 0 µsec. Use the following procedure to change the forward and reverse path delay: 1. Click on the HOST RF tab. The HOST RF display will open within the DEMS main window as shown in Figure 4-14. Right-click here to open the Host Fwd Delay pop-up screen Right-click here to open the Host Rev Delay pop-up screen Right-click here to open the Host Div Rev Delay pop-up screen Figure 4-14. HOST RF Display Page 4-17 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 4: Operation 2. Right-click on the Host Fwd Delay section of the display (see Figure 4-14). The Host Fwd Delay pop-up screen will open as shown in Figure 4-15. 3. Obtain the value of the forward delay as specified in the system design plan. The delay is adjustable in 0.1 µsec steps. 4. Enter the forward path delay value and click OK to close the pop-up screen and to make the changes take effect. 5. Repeat the process for reverse delay and diversity reverse delay by right-clicking on the appropriate delay section (see Figure 4-14) and then entering the required delay value in the pop-up screen. 6. Click OK to close each pop-up screen and to make the changes take effect. Figure 4-15. Host Fwd Delay Pop-Up Screen Page 4-18 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance SECTION 5: MAINTENANCE SYSTEM MAINTENANCE OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 FAULT DETECTION AND ALARM REPORTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 FAULT ISOLATION AND TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5 TEST PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10 1.1 Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 4.1 Optical Power Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10 4.2 Optical Loopback Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12 MAINTENANCE PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13 5.1 Scheduled Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13 5.2 Remote Unit Outdoor Cabinet Filters Cleaning Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14 5.3 Host Unit Fan Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 5.4 Spectrum Transport Module Fan Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16 5.5 Linear Power Amplifier Fan Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19 _________________________________________________________________________________________________________ SYSTEM MAINTENANCE OVERVIEW This section explains the Digivance system fault detection and alarm reporting system, provides a method for isolating and troubleshooting faults, and provides test and maintenance procedures. The Digivance system requires minimal regular maintenance to insure continuous and satisfactory operation. Components that require regular replacement, cleaning, or testing include the HU and RU fans and the RU outdoor cabinet air-filters. Maintenance also includes diagnosing and correcting service problems as they occur. When an alarm is reported, it will be necessary to follow a systematic troubleshooting procedure to locate the problem. Once the source of the problem is isolated, the appropriate corrective action can be taken to restore service. The only internal components that can be replaced are the cooling fans which mount in the HU, RU, and LPA. The failure of any other component within a unit will required replacement of that unit. 1.1 Tools and Materials The following tools and materials are required in order to complete the procedures in this section: • • • • • • ESD wrist strap IR filtering safety glasses Patch cords with SC connectors 15 dB in-line SC optical attenuators Optical power meter (1550 and 1310 nm) TORX screwdriver (with T10 bit) Page 5-1 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance FAULT DETECTION AND ALARM REPORTING The Digivance system on-board embedded software detects various unit and system faults and reports them as either Major or Minor alarms. A Major alarm indicates that the system has failed in a way that directly affects RF transport performance. This usually means that some calls or perhaps all calls cannot be made over the system. A Minor alarm means that system performance is not affected or in some cases, that the performance may no longer be optimal. Four types of faults cause a minor alarm to be reported: overtemperature, fan failure, diversity path failure, and an external minor fault (user defined fault). All other faults are reported as a Major alarm. Reporting of Major and Minor alarms is accomplished through the HU alarm contacts, the unit front panel LED’s, the DEMS software Graphical User Interface (GUI), and the Network Operations Center - Network Element Manager (NOC/NEM) interface. The HU is equipped with a set of both normally open (NO) and normally closed (NC) alarm contacts which are used to report both Major and Minor alarms to an external alarm system. The alarm contacts summarize the inputs so that any Major or Minor alarm will trigger an alarm report to the external alarm system. The HU, STM, and LPA front panel LED indicators are used to report specific alarms which are reflected in the LED colors: Green, Red, Yellow, and Off. A description of the Host Unit, Linear Power Amplifier, and Spectrum Transport Module LED indicators is provided respectively in Table 5-1, Table 5-2, and Table 5-3. The DEMS software GUI provides both a summary and a more detailed list of alarm information that includes unit and module level faults, circuit faults, and measured value faults such as voltages, RF power, and temperature. A summary showing a list of all systems and their current alarm status is presented through the Alarm OverView display. A detailed list of alarm information is presented through the HOST alarm display and the REMOTE alarm display. All the inputs that the system reports as alarms are shown in the HOST and REMOTE alarm displays. The NOC/NEM interface provides the same summary and detailed list of alarm information as the DEMS software GUI but in an ASCII text string format. Sending the command GET ALARM SUMMARY produces a list of all systems and their current alarm status. Sending the command GET ALARM ALL for a specific system will produce a detailed list of alarm information for the specified system. Page 5-2 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Table 5-1. Host Unit LED Indicators INDICATOR COLOR DESCRIPTION Green Off Indicates if the HU is powered or un-powered. The DC power source is on. The DC power source is off. POWER STANDBY Indicates if the system is in the standby, normal, test, or program load mode. Green (blinking) The HU is in the standby mode. Yellow (blinking) The HU is in the program load mode. Red (blinking) The HU is in the test mode. The HU is in the normal mode. Off HOST UNIT Green Yellow Red Indicates if the HU is normal, over temperature, or if a fault is detected. The HU is normal. High temperature detected in HU. Fault detected by the HU or HU/RU band mismatch. Green Yellow Red Indicates if an alarm is detected at the RU. No alarms detected at the RU. A minor alarm is detected at the RU. A major alarm is detected at the RU. Green Yellow Red Indicates if the forward path RF signal level is normal, above overdrive threshold, or below underdrive threshold. The RF signal level is normal The RF signal level is below the underdrive threshold. The RF signal level is above the overdrive threshold. REMOTE UNIT DRIVE PORT 1/PORT 2 Green Red Indicates if the reverse path optical signal received from the RU is normal or if errors are detected. The reverse path optical signal is normal. Excessive errors are detected in the reverse path optical signal or the HU can’t communicate with the STM. Table 5-2. Linear Power Amplifier LED Indicator INDICATOR COLOR DESCRIPTION STATUS Indicates the operational state of the LPA and whether or not any faults are detected. Green (blinking) The LPA is in the normal state. Green The LPA is in a forced shutdown state, no faults detected. Yellow (blinking) The LPA is in the normal state, minor fault detected. Yellow The LPA is initializing. Red The LPA is in an internal shutdown state, major fault detected. Page 5-3 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Table 5-3. Spectrum Transport Module LED Indicators INDICATOR COLOR DESCRIPTION Green Red Indicates if the STM is powered by the AC power source or the back-up battery system. The STM is powered by the AC power source. The STM is powered by the back-up battery system. AC POWER STANDBY Indicates if the system is in the standby, normal, test, or program load mode. Green (blinking) The STM is in the standby mode. Yellow (blinking) The STM is in the program load mode. The STM is in the test mode. Red (blinking) The STM is in the normal mode. Off HOST UNIT Green Yellow Red STM Red Indicates if the STM is normal, over temperature, or if a fault is detected. The STM is normal. The STM is over temperature due to high ambient temperature or the fan has failed. Fault detected by the STM or HU/RU band mismatch. Green Yellow Red Indicates if the LPA is normal, over temperature, has a fan failure, or is faulty. The LPA is normal. The LPA is over temperature or the fan has failed. Internal fault detected in the LPA. Green Red Indicates if the forward path VSWR is above or below the threshold. The VSWR is below the threshold. The VSWR is above the threshold. Green Yellow PA VSWR PORT 1/PORT 2 Green Red Page 5-4 © 2003, ADC Telecommunications, Inc. Indicates if an alarm is detected at the HU. No alarms detected at the HU. A minor alarm is detected at the HU. A major alarm is detected at the HU. Indicates if the forward path optical signal received from the HU is normal or if errors are detected. The forward path optical signal is normal. Excessive errors are detected in the forward path optical signal or the STM can’t communicate with the HU. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance FAULT ISOLATION AND TROUBLESHOOTING Alarm information may be accessed and faults isolated using the information provided by the unit front panel LED indicators, the DEMS software GUI alarm displays, or the NOC-EMS interface. Because the alarm information provided by the DEMS GUI and the NOC-EMS interface is very detailed, refer to Table 5-4, Table 5-5, or Table 5-6 to determine the unit LED indicator (Host Unit, Remote Unit, or LPA) that corresponds to the indicated alarm. Then refer to Table 5-7, Table 5-8, or Table 5-9 to identify the problem, check out the possible causes, and take corrective action. Table 5-4. Host Unit Major and Minor Alarms MAJOR ALARM LED INDICATOR MAJOR ALARM LED INDICATOR Operating Mode (Does not apply) Fwd Synth Lock HOST UNIT 8 Volt HOST UNIT RF Mute (Does not apply) Pri No Light (Not implemented) Major Extern Output (Does not apply) Pri Fwd Mux Lock HOST UNIT Companion Lost PORT 1/PORT 2 Pri Rev Synth Lock HOST UNIT Overdrive DRIVE Temperature HOST UNIT Unit Mismatch HOST UNIT Sec No Light (Does not apply) Link Alarm (Does not apply) Sec Errors (Does not apply) 3.8 Volt HOST UNIT Sec Rev Synth Lock HOST UNIT Pri Laser Fail HOST UNIT Underdrive DRIVE Pri Errors PORT 1/PORT 2 Minor Extern Output (Does not apply) MINOR ALARMS LED INDICATOR Table 5-5. Remote Unit Major Alarms MAJOR ALARM LED INDICATOR MAJOR ALARM LED INDICATOR Operating Mode (Does not apply) Battery Voltage (Does not apply) 3.8 Volt STM Pri Laser Fail STM Pri Errors PORT 1/PORT 2 Fwd Synth Lock STM Reference Synth Lock STM System VSWR VSWR LPA DC Fail PA LPA Low Power PA LPA VSWR PA Unit Mismatch STM Link Alarm (Does not apply) Converter STM AC Fail AC POWER Pri No Light PORT 1/PORT 2 8 Volt STM Pri Rev Synth Lock STM Pri Rev Mux Lock STM LPA Detect PA RF Mute (Does not apply) LPA Over Power PA LPA Loop Failed PA Companion Lost PORT 1/PORT 2 Major Extern Alarm Inp (Does not apply) – – Page 5-5 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Table 5-6. Remote Unit Minor Alarms MINOR ALARM LED INDICATOR MINOR ALARM LED INDICATOR Temperature STM Sec Laser Fail (Does not apply) Sec Rev Mux Lock (Does not apply) Sec Rev Synth Lock (Does not apply) Rev Path Level (Does not apply) LPA Disable STATUS (LPA) LPA Fan PA LPA High Temp PA RF Out Very Low (Does not apply) Minor Extern Alarm Inp (Does not apply) During normal HU operation, all LED’s should be green except the STANDBY LED which should be Off. When a Minor alarm occurs, one or more of the LED’s will turn yellow. When a Major alarm occurs, one or more of the LED’s will turn red. It is recommended that whenever there are multiple alarms, the optical alarms should be checked and cleared first. Because the host and remote units function as a system, a fault in the fiber optic link will cause various unit alarms to be reported. Table 5-7. Host Unit Fault Isolation and Troubleshooting LED: POWER Color: Off Alarm Type: Major PROBLEM: The HU is not powered. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The fuse is open or removed from the fuse panel. 1. Replace or reinstall fuse at fuse panel. LED: STANDBY Color: Green (blinking) or Alarm Type: None Yellow (blinking) PROBLEM: The HU is out of service. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The HU is in the standby (green) or program load (yellow) mode. 1. Use DEMS to place the HU in the normal (off) mode. LED: HOST UNIT Alarm Type: Minor Color: Yellow PROBLEM: The HU is overheating. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Air intake or exhaust opening to HU chassis is blocked 2. Ambient temperature >> 50º C/122º F. 3. Faulty fan. 1. Remove cause of air-flow blockage. LED: HOST UNIT Alarm Type: Major Color: Red 2. Reduce ambient temperature. 3. Replace HU fan (See Section 5.3). PROBLEM: A major alarm fault detected by HU. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Fiber optic link fault. 1. Follow procedure specified when the PORT 1/ PORT 2 LED is red. 2. Replace HU or STM with correct unit. 3. Replace the HU. 2. HU and STM band mismatch. 3. The HU has failed. Page 5-6 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Table 5-7. Host Unit Fault Isolation and Troubleshooting, continued LED: REMOTE UNIT Color: Yellow Alarm Type: Minor PROBLEM: A minor alarm fault is detected at the RU. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The STM or LPA is overheating. 1. Check RU LED indicators and refer to Table 5-8 LED: REMOTE UNIT Alarm Type: Major Color: Red PROBLEM: A major alarm fault is detected at the RU. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Fiber optic link fault. 2. AC power failure at RU. 3. High VSWR. 4. The RU cabinet door is open or the STM or LPA has failed. 1. Check RU LED indicators and refer to Table 5-8. 2. Check RU LED indicators and refer to Table 5-8. 3. Check RU LED indicators and refer to Table 5-8. 4. Check RU LED indicators and refer to Table 5-8. LED: DRIVE Alarm Type: Minor Color: Yellow PROBLEM: The RF input signal level is below the underdrive threshold. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty BTS or faulty coaxial connection 1. Check forward path signal level at the HU. between the HU and the BTS. 2. Incorrect attenuation in forward path RF coax- 2. Check Host Forward Attenuator setting and ial link. adjust if attenuation is too high. LED: DRIVE Color: Red Alarm Type: None PROBLEM: The RF signal is above the overdrive threshold. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Composite output signal level from BTS is too 1. Check BTS composite output signal level and high. adjust if too high. 2. Incorrect attenuation in forward path RF 2. Check Forward Attenuator setting and adjust if coaxial link. attenuation is too low. LED: PORT 1/PORT 2 Color: Red Alarm Type: Major PROBLEM: Excessive errors are detected in the reverse path optical signal. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty reverse path optical fiber. 1. Test optical fiber. Clean connector if dirty. Repair or replace optical fiber if faulty. (See Section 4.1). 2. Test optical ports. Replace HU or STM if port is faulty (See Section 4.2). 2. Faulty optical transmit port at the STM or faulty optical receive port at the HU Page 5-7 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance During normal STM operation, all LED’s should be green except the STANDBY LED which should be Off. When a Minor alarm occurs, one or more of the LED’s will turn yellow. When a Major alarm occurs, one or more of the LED’s will turn red. It is recommended that whenever there are multiple alarms, the optical alarms should be checked and cleared first. Because the host and remote units function as a system, a fault in the fiber optic link will cause various unit alarms to be reported. Table 5-8. STM Fault Isolation and Troubleshooting LED: AC POWER Color: Off Alarm Type: Major PROBLEM: The RU is powered by the battery back-up system. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The AC power system circuit breaker is open or the AC power has failed. 2. The STM has failed. 1. Check the AC power system, repair as needed, and reset circuit breaker. 2. Replace the STM. LED: STANDBY Color: Green (blinking) or Alarm Type: None Yellow (blinking) PROBLEM: The RU is out of service. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The RU is in the standby (green) or program load (yellow) mode. 1. Use DEMS to place the RU in the normal (off) mode. LED: HOST UNIT Alarm Type: Minor Color: Yellow Problem: A minor alarm fault is detected at the HU. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The HU is overheating. 1. Check HU LED indicators and refer to Table 5-7 LED: HOST UNIT Alarm Type: Major Color: Red PROBLEM: A major alarm fault is detected at the HU. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Fiber optic link fault. 2. The HU is not powered. 3. The HU has failed. 1. Check HU LED indicators and refer to Table 5-7. 2. Check HU LED indicators and refer to Table 5-7. 3. Check HU LED indicators and refer to Table 5-7. LED: STM Alarm: Minor Color: Yellow PROBLEM: The STM is overheating. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Air intake or exhaust opening to the remote unit cabinet is blocked 2. Ambient temperature >> 50º C/122º F. 3. Faulty fan. 1. Remove cause of air-flow blockage. Page 5-8 © 2003, ADC Telecommunications, Inc. 2. Reduce ambient temperature. 3. Replace STM fan (See Section 5.4). ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Table 5-8. STM Fault Isolation and Troubleshooting, continued LED: STM Color: Red Alarm Type: Major PROBLEM: A major alarm fault detected by the STM. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Fiber optic link fault. 2. The HU is not powered. 3. HU and STM band mismatch. 4. The STM has failed. 1. Follow procedure specified when the PORT 1/ PORT 2 LED is red. 2. Check HU LED indicators and refer to Table 5-7 3. Replace HU or STM with correct unit. 4. Replace the STM. LED: PA Alarm Type: Minor Color: Yellow PROBLEM: The LPA is overheating. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Air intake or exhaust opening to the remote unit cabinet is blocked 2. Ambient temperature > 50º C/122º F. 3. Faulty fan. 1. Remove cause of air-flow blockage. LED: PA Alarm Type: Major Color: Red 2. Reduce ambient temperature. 3. Replace LPA fan (See Section 5.5). PROBLEM: A major alarm fault is detected by the LPA. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The STM to LPA connecting cable is faulty. 2. The LPA has failed. 1. Inspect cable and repair or replace if faulty. 2. Check LPA and refer to Table 5-9. Replace the LPA if it is faulty. 3. Replace the STM. 3. The STM has failed. LED: VSWR Color: Red Alarm Type: Major PROBLEM: The forward path VSWR is above the threshold. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty antenna or antenna system. 1. Check the antenna circuit for shorts or opens (including lightning protector). 2. Check the antenna cable for faulty connections. 3. Replace the STM. 2. Faulty antenna cable. 3. The STM has failed. LED: PORT 1/PORT 2 Color: Red Alarm Type: Major PROBLEM: Excessive errors are detected in the forward path optical signal. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. Faulty forward path optical fiber. 1. Test optical fiber. Clean connector if dirty. Repair or replace optical fiber if faulty. (See Section 4.1). Page 5-9 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance During normal LPA operation, the STATUS LED should be blinking green (normal operation) or blinking yellow (minor fault). Table 5-9. LPA Fault Isolation and Troubleshooting LED: STATUS Color: Green Alarm Type: None PROBLEM: The LPA is in the forced shutdown state. POSSIBLE CAUSES 1.The MUTE/NORM/RESET switch is in the MUTE position or the LPA was set in the dis -able mode through the DEMS computer. 1.Place MUTE/NORM/RESET switch in the NORM position or use DEMS to enable the LPA. LED: STATUS Alarm Type: Minor Color: Yellow (blinking) PROBLEM: The LPA detects a minor fault. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The LPA fan has failed. 1. Replace LPA fan. (see Section 5.5) LED: STATUS Alarm Type: Major Color: Red PROBLEM: The LPA is in a forced shutdown state. POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS 1. The STM to LPA connecting cable is faulty. 2. The LPA fan has failed allowing overheating. 3. Air intake or exhaust opening to the remote unit outdoor cabinet is blocked. 4. Ambient temperature > 50º C/122º F. 5. The LPA is faulty. 1. Inspect cable and repair or replace if faulty. 2. Replace LPA fan. (see Section 5.5) 3. Remove cause of air-flow blockage. 4. Reduce ambient temperature 5. Replace LPA. TEST PROCEDURES This section provides procedures for common troubleshooting and maintenance tests. Refer to these procedures as needed when specified in the Fault Isolation and Troubleshooting tables in Section 3. 4.1 Optical Power Test A break in an optical fiber or a fault with the optical connector will interrupt communications between linked components or generate excessive errors. Use the following procedure to isolate a problem with an optical fiber or connector. Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. Page 5-10 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 1. Put on the IR filtering safety glasses. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. At the HU and at the STM, place the On/Off switches in the OFF position (press O). Note: Turning off the HU and STM disables the respective lasers which is necessary in order to safely inspect and clean the optical connectors. 4. Disconnect the optical fiber connectors for the fiber to be tested at the HU and the STM. 5. Inspect the optical connectors. Verify that connectors are clean and that no scratches or imperfections are visible on the fiber end. Clean and polish the optical connectors if necessary. 6. Connect the optical power meter to the output (receiver) end of the optical fiber. If an attenuator was included in the fiber link, make sure the attenuator is installed. 7. Connect the input (transmitter) end of the optical fiber to the far end HU or STM. 8. At the far end HU or STM, place the On/Off switch in the ON position (press I). 9. Using the far end HU or STM as an optical light source, measure the optical power at the near end of the optical fiber. The power level of the optical input signal at the HU or STM must fall within the following ranges: STM Forward Path Input Signal (Port 1): –15 to –25 dBm (with attenuator installed) HU Reverse Path Input Signal (Port 2): –15 to –23 dBm (with attenuator installed) If the power level of the received optical signal is within the specified range, the optical fiber and the far end unit are good. If the power level of the received signal is not with the specified range, either the optical fiber is faulty or the far end unit optical transmitter is faulty. Continue with test procedure to isolate the problem 10. At the far end HU or STM, place the On/Off switch in the OFF position (press O). 11. Disconnect the optical power meter from the near end of the optical fiber. 12. Connect the optical power meter to the far end HU (Port 1) or STM (Port 2). 13. At the far end HU or STM, place the On/Off switch in the ON position (press I). 14. Measure the optical output power of the far end HU or STM. The power level of the optical output signal from the HU or STM must meet the following specification: HU Forward Path Output Signal (Port 1): 0 + 1 dBm STM Reverse Path Output Signal (Ports 2 and 3): +2 + 1 dBm If the power level of the optical output signal is within specifications, the optical fiber is faulty. If the power level of the optical signal is not within specifications, the far end HU or STM optical transmitter is faulty. 15. At the far end HU or STM, place the On/Off switch in the OFF position (press O). 16. Disconnect the optical power meter from the far end HU or STM. 17. Reconnect the optical fibers at the HU and the STM. Page 5-11 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 18. Repeat steps 3 through 17 for each optical fiber that requires testing. 19. When ready to put the system back into service, place the On/Off switch in the ON position (press I) at both the HU and STM. 20. Notify the NOC or alarm monitoring service that the system is going back online. 4.2 Optical Loopback Test The following procedures provide tests to determine if an optical port fault exists with the Host Unit or with the STM. Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. 4.2.1 Host Loopback Test 1. Put on the IR filtering safety glasses. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. At the HU, place the On/Off switch in the OFF position (press O). 4. Disconnect the optical fiber connectors from the PORT 1 and PORT 2 optical ports and place a dust cap over each connector. 5. Plug a 15 dB in-line optical attenuator into the PORT 1 optical port. 6. Connect a patch cord between the optical attenuator and the PORT 2 optical port. 7. Place the On/Off switch in the ON position (press I) and observe the PORT 1/PORT 2 LED indicator. 8. The PORT 1/PORT 2 LED indicator will turn either red or green. If the LED turns red, either the PORT 1 optical transmitter or the PORT 2 receiver is faulty. If the LED turns green, both PORT 1 and PORT 2 optical ports are good. 9. Place the On/Off switch in the OFF position (press O). 10. Remove the dust caps from the optical fiber connectors. 11. Clean each connector (follow connector supplier’s recommendations) and then insert each connector into the appropriate optical port. 12. When ready to put the unit back into service, place the On/Off switch in the ON position (press I). 13. Notify the NOC or alarm monitoring service that the system is going back online. Page 5-12 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 4.2.2 STM Loopback Test 1. Put on the IR filtering safety glasses. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. At the STM, place the On/Off switch in the OFF position (press O). 4. Disconnect the optical fiber connectors from the PORT 1 and PORT 2 optical ports and place a dust cap over each connector. 5. Plug a 15 dB in-line optical attenuator into the PORT 1 optical port. 6. Connect a patch cord between the optical attenuator and the PORT 2 optical port. 7. Place the On/Off switch in the ON position (press I) and observe the PORT 1/PORT2 LED indicator. 8. The PORT 1/PORT 2 LED indicator will turn either red or green. If the LED turns red, either the PORT 1 receiver is faulty or the PORT 2 transmitter is faulty. If the LED turns green, both PORT 1 and PORT 2 optical ports are good. 9. Place the On/Off switch in the OFF position (press O). 10. Remove the dust caps from the optical fiber connectors. 11. Clean each connector (follow connector supplier’s recommendations) and then insert each connector into the appropriate optical port. 12. When ready to put the unit back into service, place the On/Off switch in the ON position (press I). 13. Notify the NOC or alarm monitoring service that the system is going back online. MAINTENANCE PROCEDURES This section specifies the system maintenance requirements and provides the procedures for the required maintenance tasks. Refer to these procedures as needed when specified in the Scheduled Maintenance table. 5.1 Scheduled Maintenance Table 5-10 lists the items that require regular maintenance and the recommended maintenance interval. Refer to the section specified in the table for the required maintenance or test procedure. Page 5-13 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Table 5-10. Scheduled Maintenance INTERVAL ITEM REQUIREMENT 12 months RU outdoor cabinet filters* Remove and clean the RU outdoor cabinet filters. Refer to Section 5.2 for the required procedure. 60 months HU Fans STM Fan LPA Fan Remove and replace the cooling fans in the HU, STM, and LPA. Refer to specified section for the required procedures: HU see Section 5.3, Section 5.4, and LPA see Section 5.5. *Though it is not recommended that the RU be installed in a salt-air environment, if done so, clean the cabinet filter on a monthly basis instead of on a 12 month basis. In addition, the RU should be inspected for corrosion due to salt, particularly near the fans and around the connectors. The MTBF of the RU may be impacted if the RU is exposed to salt-air. 5.2 Remote Unit Outdoor Cabinet Filters Cleaning Procedure The RU outdoor cabinet filters clean the RU intake air before it enters the cabinet. The filters should be cleaned approximately once per year and more often in extremely dirty environments. If the cabinet temperature gradually rises over a long period of time and there are no fan failures, it is possible that the filter is dirty and requires cleaning. Use the following procedure to clean the RU outdoor cabinet filters: 1. Open the RU outdoor cabinet door as shown in Figure 5-1. 2. TBD 3. TBD 4. TBD 5. TBD Drawing not available Figure 5-1. Air Filter Removal and Replacement Page 5-14 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 5.3 Host Unit Fan Replacement Procedure The HU is equipped with two cooling fans which are located on the right side of the HU enclosure. The cooling fans blow cool air into the enclosure. Heated air is exhausted through the vent openings on the left side of the enclosure. Replacement of the fans requires that the HU be turned off for a short period of time. Use the following procedure to remove and replace the HU cooling fans: 1. Before working on the HU or handling a fan, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. Warning: Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU, STM, or LPA and when handling electronic components. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. Place the HU On/Off switch in the OFF position (press O). 4. Remove the six flat-head screws (requires TORX screwdriver with T10 bit) that secure the fan/grill assembly to the right side of the HU enclosure as shown in Figure 5-2. Save screws for reuse. 16986-A Figure 5-2. Host Unit Fan/Grill Assembly Removal 5. Carefully withdraw the fan/grill assembly from the enclosure until the wiring harness is exposed and the connectors are accessible. 6. Lift the small latch on each wiring harness connector and carefully unplug each connector from the circuit board connector. 7. Remove the plastic rivets that secure each fan to the grill by pushing outward on the rivet center post until the rivet can be withdrawn from the grill as shown in Figure 5-3. Page 5-15 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 16173-B Figure 5-3. Removing Host Unit Fans From Grill 8. Remove both fans from the grill 9. Use the rivets removed in step 7 to secure the replacement fans to the grill. Orient each fan so the wiring harness is on the top and the arrow on the fan points into the enclosure. 10. Connect the two wiring harness connectors to the circuit board connectors. 11. Secure the fan/grill assembly to the side of the enclosure (see Figure 5-2) using the six flat-head screws removed in step 4. 12. Place the HU On/Off switch in the ON position (press I). 13. Verify that the fans run properly following power-up. 14. Notify the NOC or alarm monitoring system operator that the system is going back online. 5.4 Spectrum Transport Module Fan Replacement Procedure The STM is equipped with a rear cooling fan that exhausts heated air from the STM enclosure. Cool air enters the STM through vent openings on the side of the enclosure. Replacement of the fan requires that the STM be turned off for a short period of time and that the STM be removed from the cabinet. Use the following procedure to remove and replace the STM cooling fan. 1. Before working on the STM or handling a fan, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. Warning: Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU, STM, or LPA and when handling electronic components. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. Place the STM On/Off switch in the OFF position (press O). 4. Disconnect the various power, fiber optic, service, alarm wiring, and coaxial cable connectors from the STM front panel as specified in Figure 5-4. Page 5-16 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance Disconnect optical fiber connectors. Place a dust cap over each cable connector and port adapter. Disconnect service connector (if present) Disconnect AC power connector Disconnect alarm connector Disconnect antenna connector 18661-A Figure 5-4. Spectrum Transport Module Cable Connections 5. Loosen the captive screws that secure the STM to the RU cabinet mounting shelf and carefully withdraw the STM from the cabinet. 6. Remove the four pan-head screws (requires TORX screwdriver with T10 bit) that secure the fan/grill assembly to rear side of the STM enclosure as shown in Figure 5-5. Save screws for reuse. 16992-A Figure 5-5. STM Fan/Grill Assembly Removal Page 5-17 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 7. Carefully withdraw the fan/grill assembly from the enclosure until the wiring harness is exposed and the connector is accessible. 8. Lift the small latch on the wiring harness connector and carefully unplug the connector from the circuit board connector. 9. Remove the plastic rivets that secure the fan to the mounting plate and grill by pushing outward on the rivet center post until the rivet can be withdrawn as shown in Figure 5-6. 10. Separate fan from the mounting plate and grill 11. Use the rivets removed in step 9 to secure the replacement fan to the mounting plate and grill. Orient the fan so the wiring harness is on the top and the arrow on the fan points away from the enclosure. Make certain the rubber grommets are left in place on the mounting plate. 12. Connect the wiring harness connector to the circuit board connector. 13. Secure the fan/grill assembly to the back of the enclosure (see Figure 5-5) using the four pan-head screws removed in step 6. Do not overtighten the screws. The screw threads can be easily stripped if too much torque is used to tighten the screws. 16993-A Figure 5-6. Removing STM Fan From Mounting Plate and Grill 14. Re-install the STM in the cabinet and then re-connect all cables in the reverse order in which they were disconnected (see Figure 5-4). 15. Place the STM On/Off switch in the ON position (press I). 16. Verify that the fan runs properly following power-up. 17. Notify the NOC or alarm monitoring system operator that the system is going back online. Page 5-18 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 5.5 Linear Power Amplifier Fan Replacement Procedure The LPA is equipped with a front and cooling fan. The front fan draws cool air into the LPA enclosure. Replacement of the fans requires that the STM be turned off for a short period of time and that the LPA be removed from the cabinet. Use the following procedure to remove and replace the LPA cooling fans. 1. Before working on the LPA or handling a fan, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. Warning: Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU, STM, or LPA and when handling electronic components. 2. Notify the NOC or alarm monitoring system operator that the system is going offline. 3. Place the STM On/Off switch in the OFF position (press O). 4. Loosen the captive screws that secure the LPA to the RU cabinet/mounting shelf and carefully withdraw the LPA from the cabinet. 5. Pull out the four retainers that secure the front fan to the LPA as shown in Figure 5-7 and same for reuse. Drawing not available Figure 5-7. LPA Fan Removal and Replacement 6. Carefully withdraw the fan assembly from the LPA until the wiring harness is exposed and the RJ-45 wiring harness connector is accessible. 7. Disconnect the fan wiring harness connector from the LPA and lift the fan assembly away from the LPA. 8. Place a small amount of anti-corrosion gel on the connector of the replacement fan assembly. 9. Orient the fan assembly so the air-flow arrow points into the LPA. Page 5-19 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 5: Maintenance 10. Connect the fan assembly wiring harness connector to the LPA internal connector. 11. Secure the fan assembly to the LPA using the four retainers removed in step 5. 12. Place the STM On/Off switch in the ON position (press I) and verify that the fan operates properly. The fan should draw air into the LPA. 13. Notify the NOC or alarm monitoring system operator that the system is going back online. Page 5-20 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 6: General Information SECTION 6: GENERAL INFORMATION Content Page WARRANTY/SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1 SOFTWARE SERVICE AGREEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1 REPAIR/EXCHANGE POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1 REPAIR CHARGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-2 REPLACEMENT/SPARE PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-2 RETURNED MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-2 CUSTOMER INFORMATION AND ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3 _________________________________________________________________________________________________________ WARRANTY/SOFTWARE The Product and Software warranty policy and warranty period for all ADC Products is published in ADC’s Warranty/Software Handbook. Contact the Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada) for warranty or software information or for a copy of the Warranty/Software Handbook. SOFTWARE SERVICE AGREEMENT ADC software service agreements for some ADC Products are available at a nominal fee. Contact the Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada) for software service agreement information. REPAIR/EXCHANGE POLICY All repairs of ADC Products must be done by ADC or an authorized representative. Any attempt to repair or modify ADC Products without written authorization from ADC voids the warranty. If a malfunction cannot be resolved by the normal troubleshooting procedures, call the Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada). A telephone consultation can sometimes resolve a problem without the need to repair or replace the ADC Product. If, during a telephone consultation, ADC determines the ADC Product needs repair, ADC will authorize the return of the affected Product for repair and provide a Return Material Authorization number and complete return shipping instructions. If time is critical, ADC can arrange to ship the replacement Product immediately. In all cases, the defective Product must be carefully packaged and returned to ADC. Page 6-1 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 6: General Information REPAIR CHARGES If the defect and the necessary repairs are covered by the warranty, and the applicable warranty period has not expired, the Buyer’s only payment obligation is to pay the shipping cost to return the defective Product. ADC will repair or replace the Product at no charge and pay the return shipping charges. Otherwise, ADC will charge a percentage of the current Customer Product price for the repair or NTF (No Trouble Found). If an advance replacement is requested, the full price of a new unit will be charged initially. Upon receipt of the defective Product, ADC will credit Buyer with 20 percent of full price charged for any Product to be Out-of-Warranty. Products must be returned within thirty (30) days to be eligible for any advance replacement credit. If repairs necessitate a visit by an ADC representative, ADC will charge the current price of a field visit plus round trip transportation charges from Minneapolis to the Buyer’s site. REPLACEMENT/SPARE PRODUCTS Replacement parts, including, but not limited to, button caps and lenses, lamps, fuses, and patch cords, are available from ADC on a special order basis. Contact the Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada) for additional information. Spare Products and accessories can be purchased from ADC. Contact Sales Administration at 1-800-366-3891, extension 73000 (in U.S.A. or Canada) or 1-952-938-8080 (outside U.S.A. and Canada) for a price quote and to place your order. RETURNED MATERIAL Contact the ADC Product Return Department at 1-800-366-3891, extension 73748 (in U.S.A. or Canada) or 952-917-3748 (outside U.S.A. and Canada) to obtain a Return Material Authorization number prior to returning an ADC Product. All returned Products must have a Return Material Authorization (RMA) number clearly marked on the outside of the package. The Return Material Authorization number is valid for 90 days from authorization. Page 6-2 © 2003, ADC Telecommunications, Inc. ADCP-75-150 • Preliminary Issue A • March 2003 • Section 6: General Information CUSTOMER INFORMATION AND ASSISTANCE PHONE: EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 U.S.A. OR CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Extension 73475 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-938-8080 Technical Assistance: +1-952-917-3475 WRITE: ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ADC TELECOMMUNICATIONS (S'PORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE 189702. ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: connectivity_tac@adc.com euro_tac@adc.com 13944-J asiapacific_tac@adc.com Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC's Technical Assistance Center. © 2003, ADC Telecommunications, Inc. All Rights Reserved Printed in U.S.A . Page 6-3 www.adc.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2003:03:21 15:49:42-06:00 Create Date : 2003:03:05 10:27:58-06:00 Title : 75150.book Creator : FrameMaker 6.0 Producer : Acrobat Distiller 4.0 for Windows Page Count : 32 Mod Date : 2003:03:21 15:49:42-06:00 Creation Date : 2003:03:05 10:27:58-06:00 Metadata Date : 2003:03:21 15:49:42-06:00 Has XFA : NoEXIF Metadata provided by EXIF.tools